Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M02-181 - BOEING #9-150
BOEING 9 -750 ROOFTOP ANTENNAS 9724 E MARGINAL wys EXPIRED 10 -08 -03 M02 -181 6 W= • u. w0 u u. z H- O Z 1- 11J uj V 0. o S al- WW IL.z w • = 0 z Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Value of Construction: Type of Fire Protection: Signature: doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 0003400018 9725 EAST MARGINAL WY S TUKW Permit Center Authorized Signature: BOEING #9 -150 9729 EAST MARGINAL WY S, TUKWILA WA THE BOEING COMPANY PO BOX 3703 M/S #1F-09, SEATTLE WA RICK FORD PO BOX 3707 M/S 46 -88, SEATTLE WA Contractor: Name: BOEING COMPANY Address: PO BOX 3707, M/S IF -09, SEATTLE, WA Contractor License No: BOEINC*294ML MECHANICAL PERMIT DESCRIPTION OF WORK: REPLACE 8 ROOF MOUTNED A/C UNITS WITH LIKE KIND UNITS. $60,000.00 Fees Collected: Uniform Mechnical Code Edition: Kt twtpw afar -) I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of w j. I am authorized to sign and obtain this mechanical permit. Date: e' r Z Print Name: le! i(/ /2- 2- 0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. MO2 -181 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 - 655 -9888 Phone: Expiration Date: 01/14/2003 MO2 -181 09/16/2002 03/15/2003 Date: C ? "1/0 — d a' $135.88 1997 Printed: 09 -16 -2002 doc: Conditions --, City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 0003400018 Permit Number: MO2 -181 Address: 9725 EAST MARGINAL WY S TUKW Status: ISSUED Suite No: Applied Date: 09/09/2002 Tenant: BOEING #9 -150 Issue Date: 09/16/2002 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296 - 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Readily accessible access to roof mounted equipment is required. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 14: Local U.L. central station supervision is required. (City Ordinance #1900) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 16: Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1900) 17: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 18: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such MO2 -181 Printed: 09 -16 -2002 Signature: Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite,100 / Tukwila, WA 98188 / (206) 431 -3670 condition or violation. 19: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575- 4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. e f/>4 D ✓ t d • MO2 -181 Date: 9 -' Printed: 09 -16 -2002 Project Name/Tenant: AZCpGrlee 9 -451) ` ' . ,�voi- op 411P. ValueBf Mechanical Equipment: Site Address : 9729 L . 440e6i.vrl G bYmY City State/Zip: r wlLr9 Tax Parcel Number: Property Owner: 231, //, Z Print name: / I k re2JO Phone: ( Phone: ( ) Street Address: R0. Bo 3707 „1 / S 4i, -48 Address: . City State/Zip: rttt uira Fax #: ( ) Contractor: Phone: ( ) Street Address: 45DX/ to -5t 2 ?4 44 / City State/Zip: Fax #: ( ) Contact Person: /4 I k 1—c a D Phone: (206 ) G SS -9B88 Street Address: 1 9 City State/Zip: Fax #: ( ) `l UILDINGIOWNER .OR'AUTHORIZED,A'GENT ::, ` ' Signature: ‘', / Date :, p_ I Print name: / I k re2JO Phone: ( ) Fax #: ( ) Address: 3 � City/State/Zip: CITY OF T IKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 R SJAI I USE ONI Y Project Number. Permit Number: Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. ECHANICALPERMITiREVIEW AND` APPROVAL REQUESTED :ITO BEFILLED OUT BY APPLICANT) Description of work to be done (please be specific): ,2CpL g 4e,e,C Y/p vNT(D "9,C r1N /TS Av /T/ Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PER JURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: = 1=DZ 11/1/99 mech permil.doc Date application expires: o3 Application taken by: (initials) ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal RESIDENTIAL: Two complete sets of attachments required with application submittal 11/2/99 miscpml.doc NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Submittal Requirements New Single. Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change - out or replacement of existing mechanical equipment Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition; NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. 1 Z RECEIPT it 2 Parcel No.: 0003400018 Permit Number: MO2 -181 U V O Address: 9725 EAST MARGINAL WY S TUKW Status: APPROVED N W Suite No: Applied Date: 09/09/2002 u� Applicant: BOEING #9 -150 Issue Date: to 11_, uj o 2 Receipt No.: R020001361 Payment Amount: 135.88 * 5 Initials: KAS Payment Date: 09/16/2002 01:31 PM N a User ID: 1684 Balance: $0.00 _ ZI— I- O Payee: BOEING 000.99.586.908.03 ? . U� .1— TRANSACTION LIST: D Type Method Description w w U U. H ' Payment Other 135.88 • Z . U N O Z ACCOUNT ITEM LIST: doc: Receipt City of Tukwila Current Pmts 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 - 3670 Amount MECHANICAL - NONRES PLAN CHECK - NONRES Description Account Code 000/322.100 108.70 000/345.830 27.18 Total: 135.88 :x' 1 716 DTAi. 000 Printed: 09 -16 -2002 1 Project • Re , t Type of nnspe tion: /' Addr es: . s Date Cal Special Instructions: /=30 Date Wanted -703 a. 0 Requester: 40 Phone No: A n„ INSPE • NO. CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Bivd., #100, Tukwila, WA 98188 [ per applicable codes. INSPECTION RECORD Retain a copy with permit • �•:.: e.�, r�'Y'•- " 4Y:':i - ;e2 i. �}¢'• t5.�;.5 ,f �:«i _i'; ?`3."�,,•y, .,1:..': t' n: �: :f ..�; l4 t' % ^_:x7. ".'AL!r'*8. 1:•,. ald,P..-k- +5•...,e CiLti . 43... 1^, •l: ... „F_'MSt�..+,59...+Y�ii.34.� >.I l.'.t: (206)431 -3670 COMMENTS: ���� / /".9 ti le Corrections required prior•to approval. $47.00 REINSPECTION EQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter vd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project CN50 ::2 � Addres : �� J�� llle : Z - G Specia Instru ion / / ®a l ' , Date Wanted: ��� Requester: m Phone No g/?JiAl lY'.`r'vK{1 CITY OFTUKWILA BUILDING DIVISION El Approved per applicable codes. 2.e, 00 4,4-m 7/ i� I y L -iD S 14Z14 /), .7 Receipt No.: !Date: INSPECTION RECORD Retain a copy with permit ��. ,iaL D$47. ' ' ' EINSPECTIO EE RE • UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ( (206)431 -3670 Fri t Corrections required prior to approval. 2 �W 0 co o J = LL w u..Q Z W O W co O— O.F— LU W H- ll. 0 W O ~ z September 3, 2003 Rick Ford P.O. Box 3707, M/S 4688 Seattle, WA 98124 Dear Permit Holder: City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: Permit Application No. MO2 -181 9725 East Marginal Wy S In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to October 4, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer Permit Technician Xc: Permit File No. MO2 -181 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431.3665 February 11, 2003 Mr. Rick Ford PO Box 3707 M/S 46 -88 Seattle, WA 98108 RE: Permit Application No. MO2 -181 Location: Boeing 9 -150 9725 East Marginal Wy S Dear Permit Holder: City of Tukwila Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: 'Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next scheduled inspection This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. The Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicant's control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to March 15, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, K �.OAD Kathryn A. Stetson Permit Technician Xc: Permit File No.MO2 -181 Bob Benedicto, Building Official Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431-3665 rowtrstontroMMAIIWAZ ACTIVITY NUMBER: MO2 -181 DATE: 09 -09 -02 PROJECT NAME: BOEING 9 -150 ROOFTOP SITE ADDRESS: 9725 EAST MARGINAL WAY SOUTH X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # — After Permit Is Issued DEPARTMENTS: w Buildin ivision Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use. Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2-28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 5 AItC 11-11197 Fire Prevention Structural ❑ Incomplete Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: m!savwomaasA erPltiRitPRWRIXnre*V*Wr~fOxrMWPeriw*sn". PERMIT COORD COPY Planning Division Permit Coordinator 0 DUE DATE: 09-10 -02 Not Applicable ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 10-08 -02 Approved ❑ Approved with Conditions [� Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LICENSE DETAIL INFORM,�,,TION Form �, Page 1 of 1 STATE OF WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES Specialty Compliance Services Division P. O. Box 44000 Olympia, WA 98504 -4000 THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS: LICENSE DETAIL INFORMATION Current Filter: None Registration# or License BOEINC*294ML Name BOEING COMPANY, THE Address 100 N RIVERSIDE Address M/C 5003 -4027 City CHICAGO State IL Zip 606061596 Phone Number 3606553907 Effective Date 7/13/1971 Expiration Date 1/14/2003 Registration Status ACTIVE Type CONSTRUCTION CONTRACTOR Entity CORPORATION Specialty Code GENERAL Other Specialties UBI Number 178005030 * * *VIEW CROSS REFERENCE FILE FOR THIS LICENSE* * * * * *VIEW PRINCIPAL OWNER(S) FOR THIS LICENSE* * * 'VIEW *VIEW CONTRACTOR BOND /SAVINGS INFORMATION * * * * * *CHECK INQUIRY FOR SUMMONS AND COMPLAINTS* * * * * * VIEW CONTRACTOR INSURANCE INFORMATION * * * New inquiry by CITY, NAME, PRINCIPAL OWNER NAME, NUMBER, UBI NUMBER or return to the L &I Construction Compliance Home Page https://wws2.wa.gov/Ini/bbip/TF2Form.asp?License=BOEINC*294ML 09/13/2002 z i • 0 co D w J co w LL Q N 3 r LO ON D. w ul g_ u. O = O~ z DRAWING I N r! X DRAWING NUMBER SHEET r i REVISION T NUNBER DPAW t� TI. E E-'FP DATE- 9- 150 —A1 Al . i2.OvER PET - I OE _ L02 _ 09-150—M1 M 1 EQUIPMENT SCHEDULE A 08 =1.02 9-150-2M1 ! 2M1 1,HH -- FLOOF PLAN A 08 11.02 08 1' .02 9 -150 —RFM In RFM 1 O HvAC — PCOF PLAN A 9 - -RFM I OR RFM 1 OR HVA'. — ROOF PLAN REMOVALS A 08 "1.02 9- 150— RFA160 RFA160 RC OF PLAN A 08.21.02 9- 150 —RF450 RF450 ± ' '0V & 27 POWER ROOF C 07 02.02 9- 150 —CM2 21 CM" 1 . AHL 7,8,9,10,1 1,13,14, 1 5 CONTRJLS — 8.07.0L ,rM 99 2. ?ROJECT SITE i REPLACE 9 -150 ROOFTOP AHU'S E XPIRED REVISION 7 OCT j 8 2063 7 -250 x BOW Bf O E VICINITY MAP OXBOW rCT 9 -150 99 FROM TEATTLE— TACOMA AIRPORT FROM DOWNTOWN SEATTLE EAST MARGINAL WA' CORPORATE PARE eY J#420735 -01 GMM EXI 158 • 900 EXIT 157- DEVELOPVIE \TAL CENTER - EXIT 158 tP 08.21.02 Q APPROVES DATE 3YM BEING BUILDING 9 -150 REPLACE 9 -150 ROOFTOP AHU'S (J #420735 -01 —W \\./ 157 TUKWILA FROM KENT ■\\ 90u &- AUBURN NO SCALE REVISION AREA MAP BY APPROVED DATE BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 CHECK. BOX AT4GrEZAW GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWS:; AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIF ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK STARTS. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. �.00RDINATE WORK WITH OTHER CRAFTS. 4 RETURN THIS SAME SET TO RICK FORD AT BUILDING 9 -51 COLUMN M 1, AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT C ECKLI ST O THESE DRAWINGS CONFORM TO THE 1997 U.B.C., L;.F.C., U.P.0 , AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA ZONING. El ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10 —A. • BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. • NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: O 1. TENANT IMPROVEMENT (STRUCTURAL). ❑ 5 SETS OF ARCHITECTURAL DRAWINGS O 5 SETS OF STRUCTURAL DRAWINGS ❑ 5 SETS OF STANDARD DETAILS ❑ 5 SETS OF ENGINEERING CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS ❑ SETS OF CONSTRUCTION SPECIFICATIONS ❑ 2. TENANT IMPROVEMENT (NON — STRUCTURAL_): ❑ 4 SETS OF ARCHITECTURAL DRAWINGS ❑ 4 SETS OF STANDARD DETAILS ❑ 4 SETS OF ENERGY CALCULATIONS D 4 SETS OF CONSTRUCTION SPECIFICATIONS ❑ 3. TENANT IMPROVEMENT (REVISION), 2 SETS. ® 4. MECHANICAL, 4 COMPLETE SETS. ❑ 5. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS. © BRIEF PROJECT NARRATIVE: REPLACE EIGHT (8) ROOF MOUNTED A/C UNITS W11H LIKE KIND UNITS. MODIFY ROOF OPENINGS TO ACCOMODATE. ACCEPTABILI THIS DESIGN AND / )R SPECIFICATION IS APPROVED E1Y" DEPT DT?AwN MDITTMAR 7-HE(i FD DATE 5 BEROSIK CHECKED APPROVED APP DATE 10.10.96 10 10.96 SI OT!Ti.E TITLE LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS FIRST FLOOR SECOND FLOOR BUILDING HEIGHT STORIES OCCUPANT LOAD: F IRE PROTECTION SEISMIC ZONE ARCHITECTURAL MASTER COL. COVER SHEET BUILDING 9 -150 HANDICAPPED REGIJIREMENTS BARRIER FREE 3 CODE SUN 34,630 S.F. 52.500 S.F. 32,45 S.F. 20,043 S.F. OCT CI c (u41;: MARY 35 ft 2 FIRST FLOOR — 1602 PEOPLE SECOND FLOOR — 315 PEOPLE OCT 0 8 2003 D.C. EXPIED EXPIED I t:_:41/Qt,:CA e„ EC TFI AL r.-, JR °�sitiG t1I �S PIP. ! CITY OF TvKtA.P. A M (HE.`iY INDUSTRY) (CI OF TUKWILA) 1994 OBC, '!.F.C., U.P.C., WASHINGTON STATE ENERGY CODE, WAC S1 -20 E,SRRIER FREE CODE AS ADOPTED OR AMENDED, AND COMP LANG - WITH THE CITY OF TUKWILA ZONING GROUP A2.1 N. A.3 TYPE II —N F.S. (SUB. RJR ONE HOUR) FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT URRENT PEJI;ION SAME'); Op7F FTEET .P NO DW(, NO 420735 -01 Al 9-150—Al nPGE1VFp cr- TuK',Al►1,A PERM'? Sif:141C+-1 COMP NP 08 11.02 AIR DIFFUSER /REGISTER /GRILLE SCHEDULE MARK No. TYPE MATERIAL FINISH 845 NECK SIZE MAX. N.C. AIRBORNE MAX TP CFM REMARKS SD -1 CEILING DIFFUSER ROUND CEILING DIFFUSER WHITE ENAMEL 3 20`0 44 .12 2265 TITUS MODEL XC -310 W /AG -65 STYLE, 2 COMBINATION DAMPER & EQUAUZING GRID SD -2 PERFORATED DIFFUSER STEEL FACE, ALUM. FRAME WHITE ENAMEL - 7'4 ?O -30 .07 -.08 190 -200 TITUS MODEL TXS, FRAME STYLE 3 FOR T -BAR CEILING, 24'x24" MODULE, MODEL D -75 DAMPER, SEE NOTE 2 SD -3 PERFORATED DIFFUSER STEEL FACE, ALUM. FRAME WHITE ENAMEL - 6 "0 34 -36 .11 -.13 185 -205 TITUS MODEL TXS, FRAME STYLE 3 FOR T -BAR CEILING, 24 "x24' MODULE, MODEL D -75 DAMPER, SEE NOTE 2 SD -4 PERFORATED DIFFUSER STEEL FACE, ALUM. FRAME WHITE ENAMEL - 5 "0 17 -30 .04 -.09 75 -120 TITUS MODEL TXS, FRAME STYLE 3 FOR T -BAR CEIUNG, 24 "x24" MODULE, FURNISHED W /MODEL 70, 160T FUSIBLE LANK, FIRE DAMPER WHERE INDICATED SD -5 RECTANG. CELL. DIFFUSER ALUMINUM WHITE ENAMEL 4 - 12'x8' 21 .06 235 TITUS SERIES 200, MODEL S -202, SURFACE FLANGE, AG -25 DAMPER SD -6 PERFORATED DIFFUSER STEEL FACE, ALUM. FRAME WHITE ENAMEL 60 1411 38 .11 725 TITUS MODEL TXS, FRAME STYLE 3 FOR T -BAR CEILING 24 "x24" MODULE SD -7 CEIUNG DIFFUSER ALUMINUM WHITE ENAMEL OFFICES 16"x12" 34 .13 670 TITUS SERIES 200, MODEL S -202, SURFACE FLANGE, ALUMINUM DAMPER SD -8 CEIUNG DIFFUSER STEEL WHITE ENAMEL TRANE YSCO36A4 w/ ECONOMZER. ROOF CURB. 14'0 23 -36 .06 -.13 645 -955 TITUS MODEL TXS, FRAME STYLE 3 FOR T -BAR CEILING, 24 "x24" MODULE. r1JRNISHED W /DIRECTIONAL BAFFLE WHERE SHOWN SD -9 CEILING DIFFUSER STEEL WHITE ENAMEL OFF,100 14'0 28 .08 575 TITUS MODEL TADS -M, FRAME STYLE 3 FOR T -BAR CEILING, 24 "x24' M',DULE, AG -85 BUTTERFLY DAMPER SD -10 CEILING DIFFUSER STEEL WHITE ENAMEL 285 15 "0 35 .11 1025 TITUS MODEL DDS, FRAME STYLE 3 FOR T -BAR CEIUNG, 24'x24" MODULE, AG -85 BUTTERFLY DAMPER SD -11 PERFOR. CEIL'G DIFFUSER STEEL FACE, ALUM. FACE WHITE ENAMEL 1075 RPM 10'4 31 .07 255 -330 TITUS MODEL TXS, FRAME STYLE 3 FOR T -BAR CEIUNG, 24 "x24" MODULE, 2 -WAY PATTERN SD -12 CEILING DIFFUSER ALUMINUM WHITE ENAMEL TRANE YSC092A4 w/ ECONOMIZER. ROOF CURB. 8"x8" - .03 100 TITUS SERIES 200, MODEL S -202, SURFACE FLANGE SD -13 PERFORATED DIFFUSER STEEL FACE, ALUM. FRAME WHITE ENAMEL OFF,100 7"4 32 .092 155 -205 TITUS MODEL TXS, FRAME STYLE 3 FOR T -BAR CEILING, 2624" MODULE SD -14 PERFOR. CEIL'G DIFFUSER STEEL FACE, ALUM. FRAME WHITE ENAMEL 67.1 .77 12'4 31 .07 360 -433 TITUS MODEL TXS, FRAME STYLE 3 FOR T -BAR CEILING, 24 "x24" MODULE SD -15 CEILING DIFFUSER ALUMINUM WHITE ENAMEL 8'0 22 .05 245 -400 TITUS MODEL TMS -M, FRAME STYLE 3 FOR T -BAR CEILING, 24 "x24" MODULE, AG -85 BUTTERFLY DAMPER SD -16 PERFORATED DIFFUSER STEEL WHITE ENAMEL 6 "0 34 .13 60 -185 TITUS MODEL PAS, 24'x24' MODULE FOR T -BAR CEILING, 3-WAY THRON, RE -USE EXIST. FIRE DAMPER SD -17 CEILING DIFFUSER ALUMINUM WHITE ENAMEL AER3131CS 10'0 32 .113 525 TITUS MODEL TAS -M, FRAME STYLE 3 FOR T -BAR CEILING, 24'x24" MODULE, AG -85 BUTTERFLY DAMPER ~ SC-1 SUPPL GRILLE ALUMINUM /STEEL WHITE ENAMEL 12"x4" 30 .23 240 -290 TITUS MODEL JFR -S260, FLANGE MOUNTING, REAR LOUVERS PARALLEL TO LONG DIMENSION & GANGED FOR POLE OPERATIONS, 45' PATTERN, SEE NOTE 1 SR -1 SUPPLY REGISTER ALUMINUM WHITE ENAMEL 18'x12' - .05 640 TITUS MODEL 272 -FS ADJUSTABLE DOUBLE DEFLECTION REGISTER W/ OPPOSED BLADE DAMPER SR -2 SUPPLY REGISTER ALUMINU WHITE ENAMEL - 12'x6' 29 .20 400 TITUS MODEL 272 -FS ADJUSTABLE DOUBLE DEFLECTION REGISTER W/ OPPOSED BLADE DAMPER FR -1 FLOOR REGISTER ALUMINUM su h e r i co i Ll ak 2 1/2%W-0" 29 .09 73 CFM /FT THUS MODEL CTH -26, 15' DEFLECTION, 1/2'' BAR SPACING, TYPE 15 MOUNTING FRAME, 07 -35 O.B. DAMPER & EQUALIZING GRID FR -2 FLOOR REGISTER ALUMINUM moDeED 4.1m. sag caux choir AEROBICS 2'x3' -0" 31 .11 55 CFM /FT TITUS MODEL CTH -26. 15' DEFLECTION, 1/2" BAR SPACING, TYPE 15 MOUNTING FRAME, XO7 -35 O.B. DAMPER & EQUALIZING GRID RAG -1 EGG CRATE ALUMINUM WHITE ENAMEL R -22 10 "x10" - - - TITUS CORE 50 -F5, LAY -IN STYLE RAG -2 PERFOR. RETURN GRILLE STEEL FACE, ALUM. FRAME WHITE ENAMEL 66.2 .85 24"x48" 27 .08 ~ 3550 TITUS MODEL TXR, FRAME STYLE 3 FOR T -BAR CEIUNG, SEE NOTE 1 RAG --3 ER - -1 PERFOR. RETURN GRILLE STEEL FACE, ALUM. FRAME WHITE ENAMEL 864 24 "x24" - - - TITUS MODEL TXR, FRAME STYLE 3 FOR T -BAR CEILING, 24 "x24' MODULE, SEE NOTE 1 EXHAUST REGISTER AL JMINUM WHITE ENAMEL 460 6 "x6" 32 .06 60 -100 TITUS CORE 50 -F5, 3/4" FLANGE BORDER, OPPOSED BLADE ALUMINUM DAMPER, 1/2"x 1/2%1/2' GRID ER -2 EXHAUST REGISTER ALUMINUM WHITE ENAMEL TRANE YSC120A4 W/ ECONOMIZER, ROOF CURB. 8'x6' 35 .13 200 -235 TITUS CORE 50 -F5, 3/4" FLANGE BORDER, OPPOSED BLADE ALUMINUM DAMPER, 1/2 "x 1/2 "x1 /2" GRID ER -3 EXHAUST REGISTER ALUMINUM WHITE ENAMEL ~ 10 16 30 .11 1210 TITUS CORE 50 -F5, 3/4' FLANGE BORDER, OPPOSED BLADE ALUMINUM DAMPER, 1/2% 1/2"x1/2" GRID ER -4 EXHAUST REGISTER M ALUINUM WHITE ENAMEL 85 12x10' 34 .17 465 -670 TITUS CORE 50 -F5, 3/4' FLANGE BORDER, OPPOSED BLADE ALUMINUM DAMPER, 1/2 "x 1/2 "x1/2' GRID ER -5 EXHAUST REGISTER ALUMINIUM WHITE ENAMEL 8"x8" 33 .11 315 TITUS CORE 50 -F5, 3/4" RANGE BORDER, OPPOSED BLADE ALUMINUM DAMPER, 1 /2 "x 1 /2'x1 /2" GRID ER -6 EXHAUST REGISTER ALUMINUM WHITE ENAMEL 14"x12' 31 __, .09 600 TITUS CORE 50 -F5, 3/4" FLANGE BORDER, OPPOSED BLADE ALUMINUM DAMPER, 1 /2 "x 1/2 "x1 /2" GRID ER -7 EXHAUST REGISTER ALUMINUM WHITE ENAMEL 14 "x14' 30 .11 900 y TITUS CORE 50 -F5, 3/4" FLANGE BORDER, OPPOSED BLADE ALUMINUM DAMPER, 1 /2 "x 1/2 "x1/2' GRID TG -1 TRANSFER GRILLE STEEL WHITE ENAMEL 30'x18' 25 .09 2110 TITUS MODEL 30 -GL, HEAVY DUTY GRILLE, #33 CORE, FLANGE MOUNTING TG -2 TRANSFER GRILLE 1ALUIMINUM WHITE ENAMEL 24 "x18' <30 .02 553 TITUS CORE 3 FL, 3/4" SPACING, 45' DEFLECTION, SURFACE MOUNT FLANGE FRAME Aso -3 G�11 6800 570 1 0 845 2 93 4 5 2C OFF.50.10C - 2 1.0 14.800 460 3 60 85 65 238 4 91 64 87 8 } 203/324 TRANS SFHD -C20 W/ ECONOMZER. ROOF CURS CONSTANT VOL1,JNE CONTROLS. 502 ExhAUST FAN 2 - - - - P -4 LAVATORY (HANDICAPPED) 1- - - - - - - - - - - - - - - - - - Aril -o FITNESS 612C 955 730 ■ 70 60 1064 1075 4 - - 1/3 1 3 .. 1' OFF,50, 00 _ 2 i� R -22 R -22 4-1 -1 - 1 D� 1/3 , - 5 . 1725 RPM 850 RPM 1075 RPM 460 460 460 3 [- -t 60 a 85 6 5 208 5 9 75 -.41111r- . - "sr 9' 64 �' 38 C . 441111R-- : ��24� 1ec QUAY 9 LLA 21C 2 Ar4U - OFFICES 350 OFF,100 60 60 85 78 67 33.0 .86 52 124 2 64 TRANE YSCO36A4 w/ ECONOMZER. ROOF CURB. Art, -8 NORT- LOBBY 1450 60 65 850 : - 4 1/3 4 OFF,100 65 �• 42 4 74 68 120 4 64 TRANE T5C048A4 W/ ECONOMIZER. ROOF CURB Amu -9 CENTER LOBBY 3200 285 80 1750 - 3 7 1/2 OFT,66,100 R -22 .70 1075 RPM 460 3 60 79 65 106.3 .87 65.5 95 0 97.2 TRANE YSC092A4 w/ ECONOMIZER. ROOF CURB. ArLJ - 10 SOUTH LOBBY 2000 60 .80 850 - .9 5 OFF,100 R -22 1 3 1075 RPM 460 3 60 78 65 67.1 .77 69 98 6 64 TRANS YSC060A4 w/ ECONOMIZER, ROOF CURB 49.7 89.2 64 TRANE YSC060A4 W/ ECONOMIZER, ROOF CURB Arlo -11 AER3131CS 1600 650 70 850 - .9 5 OFF,100 R -22 1/3 1075 RPM 460 3 60 80 65 63.3 .76 - - - - - - - - _ - - - - - - - - - - - - - - TRANE YCD 210 C4L ABA W/ ECONOMIZER, TRANS CURB MU-13 AEROBICS 2100 850 .65 850 - .9 5 OFF,100 R -22 1/3 1075 RPM 460 3 60 80 65 66.2 .85 49 7 89.2 64 TRANE YSC060A4 W/ ECONOMIZER, ROOF CURB A1U -14 2ra.FLR.CONF.RM 4300 1300 .50 864 - 3 10 OFF,66,100 R -22 3 4 1075 RPM 460 3 60 85 65 140.3 .93 58.4 90.6 121.5 TRANE YSC120A4 W/ ECONOMIZER, ROOF CURB. MU -15 2nd FLR.CONF.RM 4300 1000 .50 864 - 3 10 OFF,66,100 R -22 1 3/4 1075 RPM 460 3 60 85 65 140.3 .93 58.4 90.6 121.5 TRANE YSC120A4 W/ ECONOMIZER, ROOF CURB. PLUMBING FIXTURE CONE:'TION SCHEDULE MARK No. DESCRIPTION WASTE (INCH) VENT (INCH) HW (INCH) CW (INCH) REMARKS P -1 WATER CLOSET 4 2 - 1 - P -2 URINAL 2 1 1/2 - 1 - P- 3 LAVATORY 2 1 1/2 1/2 1/2 .5 GPM FLOW RESTRICTOR HW & CW P -4 LAVATORY (HANDICAPPED) 2 1 1/2 1/2 1/2 .5 GPM FLOW RESTRICTOR HW & CW P -5 SERVICE SINK 2 2 1/2 1/2 - P -6 SHOWERHEAD & CONTROL VALVE - - 1/2 1/2 3 GPM FLOW RESTRICTOR IN SHOWER HEAD P -7 ELECTRIC WATER COOLER 1 1/2 1 1/2 - 1/2 BARRIER -FREE STYLE P -8 DRINKING FOUNTAIN 1 1/2 1 1/2 - 1/2 - P -9 CUSPIDOR 1 1/2 1 1/2 - - 1/4" O.D. COPPER FIELD CONNECTION TO P -8 FD -1 FLOOR DRAIN 2 1 1/2 - - 1/2' TRAP PRIMER WHERE SHOWN FFD -1 FUNNEL FLOOR DRAIN 2 1 1/2 - - 1/2' TRAP PRIMER •EXHAUST FAN SCHEDULE MARK No. LOCATION AREA • SERVED CFM EXT. SP IN WC W -FEL DIA -IN RPM REMARKS BHP DRIVE TYPE ROTATION- DISCHARGE MOTOR REMARKS HP !VOLTS PHASE HERTZ EF - ROOF FIRST FLR.TOILFT /LOCKERS 7440 50 - 416 - 1.43 BELT - 2 460 3 60 PENN VENTILATOR MODEL 0836 OR EQUAL W /BACKDRAFT DAMPER EF -2 ROOF SECOND FLOOR TOILET 310 125 - 1805 - - BELT - 1/6 120 1 60 PENN VENTILATOR MODEL 0636 OR EQUAL W /BACKDRAFT DAMPER EF -3 ROOF MECH. ROOM 2160 .25 - 580 - - BELT - 1/4 120 1 60 PENN VENTILATOR MODEL 0636 OR EQUAL W /BACKDRAFT DAMPER F -1 THRU F -4 WALL MTD. AEROBICS -1st. FLOOR NOTE 2 - 16'0 NOTE 2 - - DIRECT - 81 WATTS 120 1 60 DAYTON 16'OSCIL ATI$G CIRCULATOR 1V/KNOB CONTROL OSHA FAN & MOTOR GUARD , UNIT HEATER MARK No. LOCATION CFM M811 EAT LAT ELECTRICAL REMARKS TOT. KW No.ELEMENTS HP VOLTS PHASE HERTZ UH -1 MECH. ROOM 1100 51.2 55 98 15.0 1 1 /20 460 3 60 TRANE MODEL UHEC- 153D0A0 W /UNIT MT'D LOW VOLT T'STAT UH2 THRU UH5 - - 25.6 55 89 7.5 1 1/50 120 1 60 TRANE MODEL UHEC- 073D0A0 W /UNIT MT'D. LOW VOLT T'STAT UH -6 THRU UH -11 2nd.FLR.CEILING PLENUM 700 25.6 55 89 7.5 1 1/50 120 1 60 TRANE MODEL UHEC- 07300A0 W /UNIT MT'D. LOW VOLT T'STAT UH -12 & UH -13 1st. FLOOR,UNFINISHED AREA 700 25.6 55 89 7.5 1 1/50 120 1 60 TRANE MODEL UHEC- 073D0A0 W /UNIT MT'D. LOW VOLT T'STAT DUCT HEATER SCHEDULE MARK No. SIZE KW No. OF STAGES VOLT PHASE HERTZ CONTROL CIRCUIT REMARKS WIDTH (INCHES) HEIGHT (INCHES) DH -1 28 16 20 3 480 3 60 24 INDEECO, TYPE QUA, W/THERMAL CUTOUTS, AIRFLOW SWITCri, I MAGNETIC CONTACTORS & CONTROL CIR TRANSFORMER REMOVE DH -2 S YM SEE NOTE 1 N ;, At4.J - 1 v` - REDRAWN FROM IIYLAR 109 -150- 4101 -M5 AREA SER'vL: . 7J1AL A REPLACE 9 -150 ROOFTOP AHU'S J#420735 -01 CF4 ,Z f TCT - ,000 . 57) 0 -2 GYM I 8170x7 1 5 I 1 - INDOOR FAP FN ' 1 RPM 6F*1 , ►P 4 845 2 93 S 8 45 r 2 43 S CO PRESSOR Mc MrW % CAPACn j TQ . '0 CiT,50.100 CONDENSER FAA PQ 1 hEATINL VEN ILATING & AIR CONDIN,NiNG UNIT SCHEDULE 14,800 v xT S PHASE 460 ELECTRICAL 3 HERTZ 60 COO-ING (85" DB AM &ENT) EAT D8"F 85 CAS HEATING LAT loTAL 1 NIA % 030u IA", I *1 5►f 'F F I OE,IPVT 65 ' 246.0 91 64 87 8 243/324 TRANE TCO 240 13401 N ' ECOWOM.TER ROOF CURB. CONSTANT vOLU1k ONTROLS POWER ExHAuST FAA 65 238 4 91 64 87 8 t 203/324 } 'ROME SFM -C20 11/ ECONOMIZER. ROOF CURB. CONSTANT vOLLAAE C1NTROIS. 502 EXHAUST FAR EAT LAT 1 HEAT NOTE 1: EF -1 REPLACE EXIST. 3 /4HP MOTOR W/ 2HP MOTOR. FAN CFM AS SHOWN ABOVE. NOTE 2: CFM- (HI)3100, (MED)2630, (L0)170 RPM- (HI)1300, (1.4E0)1 100, (L0)700 RAISON BY M DITTMAR C HARRAH APPROVED DATE 01.28.02 08.21.02 SYM REVISION BY APPROVED DATE i MARK No. HWH -1 UH2 THRU UH5 INPUT RATING AGA -MBH 30365 EA. APPROVED BY TANK STORAGE GAL 940 GAL ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT i?EIAARh S CODE STAMP (ASME) 150 PSI WP DATE FIRST HR. GAL. 100'F RISE DOMESTIC HOT WATER_/ STORAGE TANK DELIVERY RATE RECOVERY GPH SIZE MOTOR DATA 100'F RISE 70'F RISE 987 TOT DRAWN OATS M. DITTMAR 01.28.02 CHECKED S BEROSIK T'NoIN€ER APPROVED 01.28 02 SUBTITLE TITLE -1 SERVICE HP 3 0 9'0 EA DOMESTIC Hw ;xRC 1/6 GENERAL NOTES EQuIPME>vT MAt E A!C YODEL Pk: SHOWN #1 1►E 50tDuLE wERf USED TO DEFK DESIGN CAPACITES AND FAINT TYPE N GENERAL_ SC►E ALES 00 NOT REFLECT TAE ACTUAL IM.KE & WOOL vo MINIM. REFER TO THE O&M MANA.A.S NOTE 1 *HERE IND•CATEL ON PLAN. FAINTS -i */ ■00E1 AG -434 FIRE BAWER. 1 V USIEL 11MK NOTE 2 WHERE WGCATED ON PLAN FURH.5r4 WI MODEL 70 FIRE DAMPER, 160•F F.SNBLE LAO. IN LIEU OF MODEL D -75 VOLUME DAMPER. EXPIR OCT 3 8 2103 VOLTS PHASE 12C 10 HERTZ CONSTRUCTION NOTES El===- REPLACE EXISTING NR HANDLING UNITS WITH UNITS LISTED. ( 8 PLACES; REMARKS (3) A.D. SMITH HOT WATER HEATERSMODEL BT -365A , GAS FIRED, W/ 940 GAL HOT WATER STORAGE TAN( W/ CIRC. PUMP, EIRG TIP( PR' 20 GPM • 11'10. EXPIRED EQUIPMENT SCHEDULE BOEING EMPLOYEES ACTIVITY CENTER BUILDING 9 -150 MLCHANICAL MASTER COL. X -X X -X • 'NV CENTER, WA CURRENT REVISION OCT 0 8 ZO, CI1. jc 1 yry.A PERMIT CL■41 El, I 1/28/2062 1.14:58 PIA SYII A /UH r ADT PANEL ---■ 1185 CFM WE INA% RE 0 P'R FIRE DAMPER AT EA PENETRATION 'F RATED WALL TYP 5 M11 M14 RE DMP'R 22/16 22 CFM 2M11 4152 LOCATE DIFFUSER 70 MSS NM CHORD CROSSBRACING UP 0 AHU -6 ,NSTALL BTN OF HEATER AFF TYP. UH -2 THRU 4H -5 / UP TO AHU -14 ON ROOF XIT 20/18 FROM U -13. TRANS. TO rU p ci ` �r�Ar�. •�I . I u� .gml` a -� . II : I: • � 10 10 � © wI -1 I •.�. 1 mews � — IL Mill. di :III � C IMES Ilk - rAtxalti 111 MI — mom. _ 1 1 1 • \ 1 SEE PAR SHEET 42/12 26/12 UP TO AHU -9 ON ROOF = A1V IN= I ■ il.': mg II 2 ON 1 rAur Wm pc 11 !•. -. ���� X 11 a FIRE DMP'R 26/16 VOLUME DAMPERS TYP 42/16 BAFFLE PLATE TO AHU -5 50 16 20/16 28/16 DN 26/16 BOO EL. 126 -0" TO AHU -5 UP TO AHU -5 ON ROOF REPLACE ROOFTOP REVISION REDRAWN FROM MYLAR 109 -150- 4152 —M1 C HARRAH J#420735 -01 C HARRAH FOR CONTIMAtION SEE SHEET 14-9 TYP 3 BY APPROVED DATE W FIRE PER 07.29.02 08.21.02 TYP 3 SYM 3 FT TYP 3 5 5 CF11 /FT PRCVIDE &Jwa —OFF PLATE tMR PORTION OF REGISTER TO BE COVERED BY VEIN NAL, 2M1114152 -M12 AG\ 3 W /FIRE TYP 5 AT DUCT PER PENETRATION OF RATED WALL REVISION M11 M14 BY 200 CR1 APPROVED GAS FLUE TO ROOF M11 M14 2M11 4152 -M13 DATE 75 CFM l'J CONTROL PANELS FOR AHU -1 THRU —6 & —12 SEE p rozcziva • ACCEPTABILITY THIS DESIGN AND /OR SPECIF1CATION IS APPROVED APPROVED BY DEPT DATE DRAWN C. HARRAH CHECKED 'ERCINIZER CHECKED APPROVED 2M1114152 -M13 DATE 07.29.02 SUBTITLE TITLE (19 MECHANICAL MASTER TYP 4 I 1 0 ( PI re' OCT d 73u3 7.5 8.5 9 2M11 4152 -M12 HVAC - FLOOR PLAN BUILDING 9 -150 COL. A- K/6 -16 A LEGEND — DUCT TYPE SMOKE DETECTOR GENERAL NOTE 11N LOBBY AREAS WHERE FLEA DUCT MUST BE 'SN'4(ED THROUGH BAR JOIST, CONTRACTOR SWILL FELD VERIFY LOCATIO OF JOIST OPENING PRIOR TO FABRICATION OF DUCTWORK. 2. SIZE DUCTS CONNECT►JNS TO AHU'S TO FR PARTICULAR UNIT SELECTED. TRANSITIONS PER SWICNA. DUCT — TYPE S11CKE DETECTOR FURNISHED & WIRED BY ELECTRICAL CONTRACTOR. INSTALLED IN DUCTWORK BY MECHMNICA :, ONTRACTOR WHERE NOT SHOWN IN PLAN VIEW INSTALS IN DUCT RISER TO MU. CONSTRUCTION NOTES FABRICATE AND INSTALL TKANSIT,ONS FR011 EXISTING BUILDiNG DUCTING THE SUPPLY Ail) RETURN OPENINGS ON NEW AHU ( 8 PLACES ) EXPIRE ocr e ?Dix? JOB NO DEV. CENTER, WA r iwG N0 CURRENT REVISION A pl i 6 DERM1T CENTER f.' SYMBOL 2M11 RECEIVE KEY PLAN C'TY OF TUKWIL Molt A 420735 -01 9- 150 -2M11 0 — o DATE 08.21.02 COMP NO SYM REVISION A REPLACE 11-150 ROOFTOP ANUS J#420735 -01 C HARRAH BY (APPROVED DATE 08.21 02 )YM v m ROOF PLA\ SCALE: 1/16 " = 1' -0" REVISION (L) /ArJ BY I. APPROVED AHU DATE KA U) Y LA f t LOCI. Sg•p P.M tf gam) 1TAII ELM p iNZEIAllig • EXPIREE OCT 0 8 2003 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE C. HARRAH CHECKED TAMER C. HARRAH CHECKED APPROVED APPROVED SUBTITLE TITLE HVAC -ROOF PLAN BUILDING 9 -150 GENERAL NOTES CONSTRUCTION NOTES INSTALL NEN AIR HANDLUNC UNIT ON ROOF. JLE SHEET M1 TO DETERMINE EACH UNITS LOCATIONS. ( a PLACES ) PECEIVED CITr ^ .A Tl)K'�,ti'It CURRENT REVISION SYMBOL 420735 -01 DATE 08.21.02 SHEET RFMIO JOB NO MECHANICAL MASTER COL. A-K/1-12 D.C., DWG NO. 9- 150 -RFM 10 COMP NO. PER.,:, L , ER 16' 8' 0 8' 16' 32' SCALE: 1/16"=r-0. REVISION REPLACE 9 -150 ROOFTOP ANUS A 4420735 - 01 BY C HARRAH • • f� 08. 21.02 I 1 1111 DATE 5YM ROOF PLAN SCALE: 1 / 16 "= 1' -O" v N Nt L', RENSIC 4 Br UV q1� APPROVED DATE A - u (3i ON MY Ma Or Mae WO In= I) EXPOSED OCT 0 8 2003 ACCEPTABILIT'T THIS DESIGN AND /0R SPECIFICATION IS APPROVED APPROVED BY DEPT DATE REMOVAL DRAWING SUBTTTLE TITLE HVAC - ROOF PLAN BUILDING 9 -150 MECHANICAL MASTER COL. A -K 1 -12 GENERAL NOTES REMOVAL NOTES DISCONNECT SUPPLY AND RETURN DUCTING - ROM EXISTING A'R HANDLERS AND REMOVE UNITS. CURRENT REVISION 420735 -01 SHE JOB NO SYMBOL A RFMIOR REt:; ErvED err). Jr, 1' i cwILA SE 12 2092 PERMIT CENTER 16' 8 0 8' 16' 32' SCALE: 1/16" D.C. `' NO. 9- 150 - RFM10R 02-•. /8r DAR 08.21.02 P NO. � I PN•k AHU 14 AHU 13 C A 1 11 � Q 1 AL Ur REVISION REPLACE 9 -150 ROOFTOP ANUS A 4420735 - 01 BY C HARRAH • • f� 08. 21.02 I 1 1111 DATE 5YM ROOF PLAN SCALE: 1 / 16 "= 1' -O" v N Nt L', RENSIC 4 Br UV q1� APPROVED DATE A - u (3i ON MY Ma Or Mae WO In= I) EXPOSED OCT 0 8 2003 ACCEPTABILIT'T THIS DESIGN AND /0R SPECIFICATION IS APPROVED APPROVED BY DEPT DATE REMOVAL DRAWING SUBTTTLE TITLE HVAC - ROOF PLAN BUILDING 9 -150 MECHANICAL MASTER COL. A -K 1 -12 GENERAL NOTES REMOVAL NOTES DISCONNECT SUPPLY AND RETURN DUCTING - ROM EXISTING A'R HANDLERS AND REMOVE UNITS. CURRENT REVISION 420735 -01 SHE JOB NO SYMBOL A RFMIOR REt:; ErvED err). Jr, 1' i cwILA SE 12 2092 PERMIT CENTER 16' 8 0 8' 16' 32' SCALE: 1/16" D.C. `' NO. 9- 150 - RFM10R 02-•. /8r DAR 08.21.02 P NO. ROOF SCUTTLE REVISION REPLACE 9 -150 ROOFTOP AHUS A BY ,1 #420735 -01 GMM APPRO'ED DATE (8.2 SYM REVISION BY APPROVED DATE G STAIR BELO* �J ROOF DRAIN AND SCUPPER (TYPICAL OF SEVEN) L B OE /IVG ACCEPTABILIT`r THIS DESIGN AND/ OR SPECIFICATION IS APPROVED APPROVED BY DEPT SUBTITLE TITLE ROOF PLAN BUILDING 9 -150 ARCHITECTURAL MASTER COL. A -K/ 1 -12 EXHick, OCT 0 8 2003 LEGEND GENERAL NOTES REFERENCE DRa1ViNGS REMOVAL NOTES L'> REMOVE AHU UNIT AND :URB COMPLETE. (AHU UNITS 7, 8, 9, ' 11, 13, 14 AND 15) DISPOSE OF MATERIAL. COORDINATE R EMOVAL W TH ELECTRICAL AND MECHANICAL SCOPES OF WORK AND THE ROC - CREW TYPICA_ OF EIGHT (8) A-lU UNITS. 2. ROOF CREW TER BACK ROOFING, CANT AND INSULATION, k; REQUIRED, FOR REMOVAL Of AHU UNIT AND CURB DISPOSE OF MATERIAL. COORDINATE REMOVAL WITH ELECTRICAL AND MECHANICAL SCOPES OF WORK AND THE MILLWRIGHTS. TYPICAL OF EIGHT (8) AHU UNITS. CONSTRUCTION NOTES ASSEMBLE AHU UNIT JOF CURB PER MANUFACTURERS INS /RECOMMENDATIONS. TYPICAL OF EIGHT (3) AHU UNITS. ATTACH AHU UNI C.URB TO ROOF FRAMING [ENGINEERING 'NIL_ PROVIDE DIRECTION AND SKETCH OF CONNECTI TO ROOF STRUCTURE AFTER REMOVAL OF EXISTINC. AHL UNIT AND CURB IS COMPLETE]. (AHU UNITS: 7, 3, 9, 10, 11, 13, 14 AND 15). TYPICAL OF EIGHT (8) AHU UNITS. 5. ROOF GREW PROVIDE RIGID INSULATION AT VOID OF AHU UNIT CURB. CUT TO FIT RIGID INSULATION. MATCH EXISTING. TYPICAL OF EIGHT (8) AHU UNITS. © ATTACH AHU UNIT TO CURB AT WOOD NAILER [ENGINEERING WILL PROVIDE DIRECTION AND SKETCH OF CONNECTION TO CURB AFTER REMOVAL OF EXISTING AHU UNIT AND CURB IS COMPLETE]. (AHU UNITS: 7, 8, 9, 10, 11, 13, 14 AND 15). TYPICAL OF EIGHT (8) AHU UNITS. 7. ROOF CREW PROVIDE CANTS AT AHU UNIT. PATCH BUILT -UP ROOF AT AHU UNIT. MATCH EXISTING. TYPICAL OF EIGHT (8) AHU UNITS. 8. ROOF CREW CLEAN -UP AND REMOVE ALL ROOFING MATERIALS DO NOT LEAVE TOOLS, EQUIPMENT OR MATERIALS ON ROOF AT COMPLETION OF PROJECT. D.C. I CURRENT REVISION SYMBOL A 420735 - 01 // \ SHEET 111 RFA160 JOB NO DWG NO 16' 8' r ECEIV„'p CIT1 OF T CENTER 0 8' 16' SCALE: 1/ 16 " =1' -0" m02..../8/ 9- 150- RFA160 DATE 08.21.02 COMP NO 32' EQUIPMENT SCHEDULE u. Ingo. (III 7 akii;• : .,. �:• %I!,. *2 . a^' i l .. i' . la "i i 7 \ii,jj!, .:':,:IF . - !. , y. l � . ;,7 ;. 1. _ .._ _ _ A s . : ar " ' l : - '11• la i i ]alii'1I�, j- «« .1 L Ca210 - - _ 17 S U urr IISJ 0 - : i B10- (3)18 C/ NF 26a,28b,30c HHN, 3/4'C 60 /NF 37c,39b,41c HHN, 3/4 "C 60 /NF SEE DRAWING 109 -150- 2003 -AE50 60/NF A11- 2/26a,28b 810 -3/14a 16b,1& (3)110 THIiN, 3/4'C 810-3/200,22 ,24c (3)110 THHN, I'C A11 - 2111 B10- :,'/7c,9b,11c �(3) #1G THHN, 3/4'C nIn 60 /NF 100 /NF All -2 /Y1r I7(0411 REPLACEMENT OF AHUJ6 J1772285 -00 B INSTALL (5) AIR W•DUNG UNITS 782729 -00 C REPLACE RMOi I#NC J4120735 -00 F K HO OEH HOWARD JV N MEHIA WHITSON VAVREK 1 - 23 - 97 8.2 7.98 07/02/02 C ® O B1C -3, I0.35.5c (3)14 THHN, 1'C 810 3/130,15i.,17c 100 /NFL ROOF PLAN 1/8" = 1' -0 'AVAS1C5 810- 3/843,106,12 (3) #4 THHN, 1'C 26o 3/25o,27b,29c j4 THHN, 1'C 100 /NF 100 /NF 0 /2o,4b,6c.4v-/It/ B10- 3/3434b,36c 810- 3/.;1a,33b,35c (344 THHN, 1'C (346 THHN, 1'C SY 60/ 48A 480V 3PH B10/70,9b,1 lc j3) #12 THHN, 3/4 "C oat 60 /NF 26o O 0 0 10 810/70,9b 11c ow 3 A.E 1 z EXPIRED OM 0 8 2003 13 14 15 16 BOE/AW FACILITIES DEPARTMENT 15745C (A11 -2/1.) N[I A 4 COMB+NATION MCTUR STARTER (ON ROOF) II 5E01 .123 WEDO (AIL - 2/5.) SPST 911 II MA 213 (2ND FL TOUT) SCALE:. NOT TO SCALE 480VAC 120VAC NR FLOW SW IN AHU -12 SUPPLY DUCT (BY MECH) 1 IwllI D aT EF -1 2HP EXH. FAN (ON ROOF) ELEMENTARY DIAGRAMS - EXHAUST FANS ACCEPTABIUTY 1DWI ,E13/1CAU1311 6 01 P KYLE HO KYL E HO 07/15/96 wan JOHN J. VAVREK 07122/97 MNICAO 0715/96 mli NAREN MEHTA 107/22/07 ELECTRICAL MASTER 15r, 16V. 1 PFUSE DUPtfx RE IPTAC.i Pau 20A, Zrv. 1 PHASE CURD aE.aPTAilf .25v, 1 PHASE. TISSA CK RECEPTACLE 15A. 125V, 1 PHASE 4-P.1.1 RECEP'AQF 30A, 120/208V, 3 PHA RECEPTACLE D 480 VOLT DROP, 3111 4P CROUSE WINDS, TYPE A. Xx AMP » a 480 VOLT RECEPT 3W, 4P, CROUSE HINDS. TYPE ARE, XX AMP • J-80x S SINGLE POLE TOGGLE SM TCH Gain 120/2G8V DISTRIBUTION PANEL ® 480/277V 31STRIBUf10N PANEL A TRANSFORMER, CAPACI'Y, PHASE & VOLTAGE AS SHOWN 4 IGROUMO O 115v MOTOR (SIZE AS NOTED) • 208 OR 230V 110TOR ;SIZE AS NOTED) 480v 3 PHASE MOTOF MOTOR STARTER. MAGNETIC MOTOR STARTER. MAGNETIC W/ DISCONNECT SWITCH ® MOTOR STARTER, MANUAL. Ia n/1i DISCONNECT SWITCH, NON - FUSED. Xx AMPERES MACHINE /EQUIPMENT NuMEER .., I HORSEPOWER 480x' 3 PHASE FAN MOTOR.* T H HEATING COIL MOMENTORY PUSHBUTTON S*ITC$ W/ PLOT LIGHT QENEf AAL NOTES; I . ) ALL CONDUIT TO BE 1/2' EMT tvt.ESS OTNERv SE NOTED 2.) Na. WIRE TO BE #12 OWN °THERMS( NOTED. 3.) THE FOLLOWNG COLOR COOW.; Of CONDUCTORS SWILL BE MEWED ON ALL CIRCUITS 900 VOLTS OR LESS. 120/208v 277/480v 'A' PHASE (LEFT BUS N PANE:) BLACK BROWN PHASE (CENTER BUS N PN(EL) RED ORANGE PH*.sE (RIGHT BUS 14 PANEL) BLUE YELLOW NEUTRAL MMITE GRAY EOOPIIENT GROUND GREEN 4.) LANGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE DEMO WHEREVER VISIBLE BY APPROPRUIELY COLORED TAPE. 5.) ALL UNUSZO CONDUIT AND MARE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG -IN CIRCUIT BREAKERS ON BMW. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 NND E3 7.) DYAD LABEL ALL RECEPT CLES, JUNCTION BOXES. SWITCHES, ETC.. WITH CIRCUIT DEITY CAT10N. 8) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. CONSTRUCTION NOTES • NR HANLER UNIT TO BE REPLACED DISCONNECT CIRCUIT FROM EXISTING UNIT AND RECONNECT TO NEW. RETAIN EXISTING CIRCO. rp otti) NEW DISCONNECTS COME WITH UNITS. IN POWER PANELS: AHU -8 REPLACE 15 AMP C.B. WITH 20. AMP C.B. �,. AHU -10 REPLACF 20 AMP C.B. WITH 25 AMP C.B. AHU -11 REPLACE 20 AMP C.B. WITH 25 AMP C.B. AHU -13 REPLACE 15 AMP C.B. WITH daJ 25 AMP C.B. I 5.. RECONNECT EXISTING DUCT SMOKE DETECTOR CONTROL WIRES TO NEW UNITS. E INSTALL WEATHERPROOF GFI RECEPT. AT UNIT INDICATED. USE 25 FT. RULE FOR DISTANCE FROM UNITS. c VERIFY IF RECEPTACLES ARE INSIDE UNITS. IF THEY DON'T EXIST INSTALL TWO OR THREE ROOF RECEPTACLES. CONFER WITH ENGINtER 4. SUPPORT HEAT/VENT WITH CMCS ADDITION. 120V & 277/480V POWER ROOF BLDG. 9 -150 6 CONFER WITH ENG1NEER FOR DETECTOR MID Cl/CS CONTROL INTERFAC,. WITH NEW UNITS. ALL nc ...RECEIVED CITY G °fi TU ovaA r, PEoi "oz.- - ELAT E a ND. 094 115 1AbT 1551901 RF450 • 9- 150 -RF450 or I FAG WY PART NUMBER DESCRIPTION COMMENTS P -1501 8 MSC -P 1501 SLAVE MODULE TS - 1 8 TS 58011 - Z74 SPACE TEMP SENSOR WITH OVERIDE SEIBE 6' PROBE TS - 2 � - B — ' TS - 5821 _ DUCT TEMP SENSOR CR - 1 H -708 CURRENT RELAY VERIS INDUSTRIES R -1 64 RH1B- U -AC24V 24VAC RELAY, SPDT, 1OAMP CONTACTS IDEC SH1B -05 RH1B RELAY SOCKET DEC I YYM OA C001 0102 SL21 SEAN S/S SS MAINT AHU 4 MSC -P150 SLV18 AHU 15 (NEW) F1LTETi FILTER INPM T ST 0102 MST SLOB SEAN I/L RC I/L HGTSTG1 CLGSTG1 CLGSTG2 BY CLG COIL OVERIDE ST 001 SEQUENCE OF OPERATION SUPPLY FAN START /STOP CONTROL. THE CMCS STARTS THE SUPPLY FAN BASED JN OCCUPANCY SCHEDULE. INITIAL SCHEDULE WILL BE 24 HOURS PROOF OF OPERATION: CURRENT SENSING RELAYS PROVIDE PROOF OF AIR FLOW FOR TILE SUPPLY FAN TO THE CMCS DUCT MOUNTED SMOKE DETECTORS: WHEN SMOKE IS DETECTED, THE DETECTOR CAUSES THE UNIT TO SHUT -DOWN VIA THE FIRE ALARM CONTROL PANEL. THE PANEL OPENS A CONTACT IN THE AHU MOTOR STARTER CAUSING THE UNIT TO SHUT -DOWN. OSA /RA DAMPERS WILL BE OPERATED BY THE TRANE MICROPROCESSER AT EACH UNIT. EXHAUST FANS, ON UNITS THAT HAVE THEM, WILL BE STARTED /STOPPED BY THE TIME MICROPROCESSER. HEATING ANO COOLING WILL BE STAGED ON /OFF AS REQUIRED TO MNNTNN SETPOINT. KONG SETPOINT WILL BE 65 DEGF, COOLING SETPOINT WILL BE 75 DEGF. AHU 2 MU 14 (NEW) APPROVED C102 1 1 C001 MSC - -P150 SLV16 AHU 13 (NEW) DATE_ SYM Mc SS MNNT HTGSTGI MCP FRG SETPTHTG AP CH H1".; ca_ • AHU 11 (NEW) A101 0003 STRCO I/IPN T CLGSTGI SS MAW MCP -CLG IMC SETPCLG AP CH AHU 10 (NEW) STRCO C004 I PNT CLGSTG2 SS MNP. SLAVES 1,2,3 LOCATED 2ND FLR COL C/10, ABOVE CEILING • SUPPLT Aft ZONE TEMPERATURE SENSOR B DM 35 IS LOCATED AT 2ND RR COL E/11 BY AHU 9 (NFW) APPROVED DATE PARTS L /ST U Q LJ >3 N O- FHI GROUND SHIELDS FROM CONN3, 5 & 6 ALL WIRES #18 AWG UNLESS OTHERWISE SPECIFIED Z CMZ : Z Z I I '• .Z • .Z • •I ► •Z • •I ► •Z • •I • .I • • • •W N. i 0 IV GNCI ti C) Q a N2 I CONN3 EXPIR v. L7 Q Q l7 Q U L3 L i u L'1 U Co IGND MSC - P1501 MICROSMART LOW INPUT /OUTPUT PACKAGED UNIT CGNTROLLER 24VAC HOT CONN5 GLLA TERMINAL STRIP CONNECTIONS IREI ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED tuciRrrw APPROVED BY DEPT. DATE 1 �► fn A U A AL) RH CHECKED APPROVED PROVED N CONN6 Ln A 1 U 8/02 N U CO SLAVE CONNECTIONS HOI PORT r TERMINAL STRIP CONNECTIONS ENCLOSURE MOUNTED AT EACH AHU TITLE CONTRAS IIIARTFR ADORES = CONN11 0 r 24 VAC SLAVE POWER ADDRESSES JIH u 7 SLV 11 AHU 8 AHU 9 AHU 10 AHU 11 AMU 13 AHU '4 AHU 15 AHU 7,8,9,10,11,13,14,15 CONTROLS BUILDING 9 -150 NC 3 GND M04 CND 405 GND A106 GND 0101 GND C102 GND GND CIO4 GND 01 DIG D2 D2G 03 D3G D4 D4G D5 D6 D6G 07 C 7G Db D8G S1 S2 S4 SLV 12 SLY 13 SLV 14 SLv 15 SLV 16 SLV 17 SLV 18 TERMINAL STRIP CONSTRUCTION NOTES SUPPLY TEMPERATURE SENSOR FAN STATUS _CC CR-1 TO G TERMINAL ON AHU - FAN S/S TO W TERMINAL ON AHU - HEAT S/S TO Y1 TERMINAL ON AHU - CLG1 S/S TO Y2 TERMINAL ON AHU - CLG2 S/S i FROM R TERMINAL ON AHU. 24 VAC 1. MOUNT ENCLOSURE ON EACH AHU, MOUNT ON PANEL OPPOSITE OF FILTER DOOR 2. EAST SIDE SLAVE TRUNK - RUN ABOVE CEIUNG FROM SLAVES LOCATED AT COL C /10 TO AHU 15, THEN TO AHU'S I1, 13 & 14. 3. WEST SIDE SLAVE TRUNK - RUN ON ROOF FROM EXISTING AHU 6, COL G/ TO AHU 9, ABOVE CEILING TO AHU 'S 7, 8 & 10. 4. ALL CMCS WIRE IN CONDUIT. 5. EACH AHU WAS A ZONE TEMPERATURE SENSOR MOUNTED 3N WALT IN AREA SERVED. 6. EACH NIU HAS A SUPPLY AIR TEMPERATURE SENSOR LOCATED ON SUPPLY DUCT, ABOVE CEILING. CM221 AHU 10, 14 & 15 ONLY 4 n ern n....w CITY OP: TUKWILA S I• P; `1 PERMIT CENTER no2 i 4 COMP