City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 1023049069
Address: 3355 S 120 PL TUKW
Suite No:
Tenant:
Name: WASHINGTON MUTUAL DATA CENTER
Address: 3355 S 120 PL, TUKWILA WA
Owner:
Name: SABEY CORPORATION
Address: 12201 TUKWILA INTL BLVD 4THFL, SEATTLE WA
Contact Person:
Name: DAVID HOWE
Address: 5005 3 AV S, SEATTLE, WA
Contractor:
Name: MCKINSTRY COMPANY
Address: 5005 3 AV S, PO BOX 24567
Contractor License No: MCKIN* *372ND
Permit Center Authorized Signature:
doc: Mech
komAif
MECHANICAL PERMIT
Permit Number: MO2 -184
Issue Date: 09/25/2002
Permit Expires On: 03/24/2003
Phone:
Phone: 206 832 -8214
Phone: 206 762 -3311
Expiration Date: 01/02/2004
DESCRIPTION OF WORK:
INSTALL RETURN AIR GRILLES AND CONTROL DAMPERS IN THE CEILING AND SUPPLY
SHAFTS. THE DAMPERS ARE REQUIRED TO CONTAIN FM -200 FIRE SUPPRESSION AGENT UPON
DISCHARGE.
Value of Construction: $15,000.00 Fees Collected:
Type of Fire Protection: Uniform Mechnical Code Edition:
Date: 9 5-
$263.31
1997
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating con or the performance of work. I am authorized to sign and obtain this mechanical permit.
Signature: �I`j(, d lkJ9C4l CJ Date: `
Print Name: '1�1� - � Li LAY ) e
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
MO2 -184 Printed: 09 -25 -2002
z
✓ 0
W w
LL
WW Q
u.
Nd
y W
z �
O
uj
w
O ▪ �
O. H
w
H --
LL z
co
O 1 '
z
doc: Conditions
City of Tukwila
•
PERMIT CONDITIONS
MO2 -184
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 1023049069 Permit Number: MO2 -184
Address: 3355 S 120 PL TUKW Status: ISSUED
Suite No: Applied Date: 09/13/2002
Tenant: WASHINGTON MUTUAL DATA CENTER Issue Date: 09/25/2002
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division.
3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be
inspected by that agency
(206- 835 - 1111).
4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These
documents are to be
maintained and available until final inspection approval is granted.
5: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as
amended, Uniform Mechanical Code
(1997 Edition), and Washington State Energy Code (1997 Edition).
6: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a
permit for, or an approval
of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to
give authority to violate
or cancel the provisions of this code shall be valid.
7: Manufacturers installation instructions required on site for the building inspectors review.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work.
Signature: 6-T LA A VI (:)A--) Date: q— 2
Print Name: - J c/L
J
Printed: 09 -25 -2002
Pr I j • ct Name/Tenant:
.
..
P i se �
Value of Mechanical
Eq�l`pment: CO-). c
Fax Fax #: IOC S3 _ goy
Site Address City
355 SNl 1 place. < l�u�;la� GOhW 1tS$
Tax Parcel Number:
loz�o� - ,.
Phone: ( j6') I - g 700
Property Owner:
Street Addres �/ City Statg/,7,i
122 0 1 -1 N ct +31. Mol y )r i/x 1 j a r td A 1�'
Fax #: (7js ze 2 _ .9,5--1
Co tract
m e ICI v• 4 CO wip
Phone: ( ■ )
S� t C, o
� ess: 3,c 1 Alm. si
coi)— 9,1 ity S te/Zip:
Fax #: ( 70 6i
7G — 3. .41
C ot}tac Perso ���
Phone: )
6 I
Stre�et A � d e c � e s s : .
�i egl ,3,0414) ve— r
„City State/Zip:
Ie... t LA___ 1 Z l/
Fax #: (7_06)
a
O3z —S6' 1 y
BUILD/NGIO R :O ' A' TH RIZED AGENT :. .... : :: ,'!''!!' 'i °
Signature:
Date: c /t3 10
Print name: 0.0 I O MAX--
Phone: (206 ) g 32 _ g 2 ,
Fax Fax #: IOC S3 _ goy
Address: SDo s 3c.,„\ Ave._ `
Cit /State/Zip r 0'12'L/
CITY OF 7 'KWI LA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
Project Number:
Permit Number:
/70,2—el
R STA(( USE UNI Y
Mechanical Permit Application
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
1� v �►� fi Iv■ Pti i
ECHANICALPERi'vMIT .REVIEW AND APPROVAL REQUESTED: (TO BE °FILLED :OUT BY APPLICANT)'`
Description of work to be done (please be specific):
1 ) Re LAYin Ai r Gr% IkS cAhd coy4j ) nee. -s
Irk - fie, ce_h1;n 10)/ S Ja S. �- cavnpefs
e r c n 'r 1 ) - Z-00 e_ Stn
p � � � v,V1i) sL 7� 0 'hot R � r
� � o rSG ( (fess(dh
&% f' r r}� �a r'ye ,
Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of
application, a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor
Registration ".
Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the
State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the
permit will be required as part of this submittal.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written
request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be
extended more than once.
Date application accepted:
Date application expires:
5 /3 -.
Application taken by: (initials)
11/2/99
rucch penult doe
II
.60
A .,
Submittal Requirements
Floor plan and system layout p MI c b t'lo r cr4 y
N
__Tyi
_Roof plan required to identify individual equipment an the location of each installation (Uniform
Mechanical Code 504 (e)) AI rba1 tub V k
N A-Details
and elevations (for roof mounted equipment) and proposed screening
Heat Loss Calculations or Washington State Energy Code Form #H -7 I\f t) ep�lo r i -
H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with"smokJdetection shut -
-off and will be routed to the Fire Prevention division for additi nal com 'nts (Uniform M chanical ‘
Code 1009). o '( ✓ s ` ,t S d 00 0 C,- i� 5',110 A dec 4 ivrt. 1 S
N
Specifications must be provided to show that replacement equipment complies with the eff ratings
and other applicable requirements of the Washington State Nonresidential Energy Code. Adio u i ,
Nr .-4-
Structural engineer's analysis is required for new and the replacement•of existing roof equipmen U
weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be
stamped by a Washington State licensed Structural Engineer. M p eynu j,. 3 -
Mechanical Permits
COMMERCIAL: Two complete sets of drawings and attachments required with application submittal
ti
RESIDENTIAL: Two complete sets of attachments required with application submittal
Change - out or replacement of existing mechanical equipment
Narrative of work to be done, including modification to duct work.
11/2/99
miscpml.doc
New Single Family Residence
Installation of Gas Fireplace
NOTE: Water heaters and vents are included in the Uniform Mechanical Code - please include any water
heaters or vents being installed or replaced.
i?r
Submittal Requirements
Heat loss calculations or Form H -6.
Equipment specifications.
Narrative with specification of equipment and chimney type.
If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe
condition.
NOTE: Water heaters and vents are included in the Uniform Mechanical Code - please include any water
heaters or vents being installed or replaced.
Or 75
''
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
RECEIPT
Parcel No.: 1023049069 Permit Number: MO2 -184
Address: 3355 S 120 PL TUKW Status: APPROVED
Suite No: Applied Date: 09/13/2002
Applicant: WASHINGTON MUTUAL DATA CENTER Issue Date:
Receipt No.: R020001407 Payment Amount: 263.31
Initials: KAS Payment Date: 09/25/2002 11:23 AM
User ID: 1684 Balance: $0.00
Payee: MCKINSTRY CO
TRANSACTION LIST:
doe: Receipt
Amount
Type
Method Description
Payment Check 5687 263.31
ACCOUNT ITEM LIST:
Current Pmts
PLAN CHECK - NONRES
Description Account Code
MECHANICAL - NONRES 000/322.100
000/345.830 52.66
210.65
Total: 263.31
Printed: 09 -25 -2002
Project: . .
- .44, 2 A4t..."17.11
Type of Inspection:
..L ,. . . .... .
Date Called:
Address:. •, • .... ,
/ 2 41'11V--1—
Special Instructions:
:_.
Date Wanted:
koa
2 g — e 2 1 0 C
Requester:
Phone No:
4 1
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
7",;
i" 14/11.,
El $47.00 ;47.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
'••
Project 11
1 4 L it \
Type of Inspection: tt
c - .S.1-14 OW' — Oq w+
Address:
33,5 S S 1 ?O r 1 1
Date Called: .
Special Instructions:
Date Wanted:
,j - 8
- 03
a.m.
P.m.
Requester:
Phone No:
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
EI Approved per applicable codes.
Corrections required prior to approval.
INSPECTION RECORD
Retain a copy with permit
COMMENTS:
Sv \ cI
$47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
(Receipt No.:
,a.,.. I � . • pr�ir'a
(206)431 -3670
Date:
P /2i6,6,/ 4,/7.? (7 ei.
Type /MR.9:: Tina,
Address:
3355 s i.,o /'L-
Date Called•
r /`I - 0.3
Special Instructions:
S I_ t
1 I ' \ 1 r
Date Wanted: tt�� �
`�Vl.
m.
Request :
( rl ri
Phone No:
S; p», ;.:4!ilsaraft;:+:�! ✓:A;:?r F� ^.y>k�rL!s�t?s:t+� Ji L�
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3
`Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
;/ .00 REINSPECTION
at 6300 Southcente
'Receipt No.:
'Date:
1w r`1 I..
A.01/ -cam/
Date:
EE REQUIRED. Pri4r to inspection, fee must be
Blvd., Suite 100. Call to schedule reinspection.
a4ri.a -pct.+ .n.
9
f) A
Project:, - : _ i A, A.-faL
2 4 v4 -
Type of Inspection:
/Lc c/ - 17,/
.
Address:- , ! . ,
.5 0 2 i 6 f';',Z
Date Called: '
Special Instructions: ' -
.., . .
, ..
Date Wanted:
Ca
Requester:
)(.. .,,X.#4 ler
-
Phone No: _ ....,
• . . ........
INSPECTION RECORD
•
Retain a copy with permit
INSPE TION NO.
ITY OF TUKWILA BUILDING DIVISION
300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable codes
4.;
M22 -49e-,/
(206)431-3670
Corrections required prior to approval.
COMMENTS: -
r6"..i..■• J./Zoo
$47.00 REINSPECTIO E REQUIRED. Prior to Inspection, fee must be
paid it t 300 Southcen er Blvd., Suite 100. Call to schedule reinspection.
'Receipt No.:
'Date:
rew
U
U)
co
Lu 0
g "Zi
u_
Lo. a
g.
I
lij
n
0 —
D. Ui
LU
tu
0
October 7, 2003
David Howe
5005 Third Avenue South
Seattle, WA 98124
RE: Permit Application No. MO2 -184
3355 South 120th Place
Dear Permit Holder:
City of Tukwila Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
W
i =
0 O
CO LU
Ncl
�
WO
Q 2 Q
LL?
N d
uj
l-0
U�
O N
• Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final O. '—
inspection. W W
t z
U=
O~
z
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila
Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the
Building Official under the provisions of this code shall expire by limitation and become null and void if the
building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work is
commenced for a period of 180 days.
Based on the above, you are hereby advised to:
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit
or last inspection; or if the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve a one -time
extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above Inspection or request and receive an extension prior to November 4,
2003, your permit will become null and void and any further work on the project will require a new permit and
associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Stefanie Spencer
Permit Technician
Xc: Permit File No. MO2 -184
Bob Benedicto, Building Official
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206- 431 -3665
ACTIVITY NUMBER: MO2 -184 DATE: 09 -13 -02
PROJECT NAME: WASHINGTON MUTUAL DATA CENTER - PH 1
SITE ADDRESS: 3355 S 120 PLACE
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Is Issued
DEPARTMENTS:
Buildin T ivision Q
Public Works ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
APPROVALS OR CORRECTIONS:
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
lI1
Fire Prevention
Structural ❑
Incomplete ❑
Planning Division
Permit Coordinator
DUE DATE: 09-17 -02
DUE DATE: 10 -15 -02
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUJING:
Please Route E3A Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
Approved ❑ Approved with Conditions a3 Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -2802
PERMIT COORD COPY
Z
;',==-.4"-Z. 7 7.7:7 — . - -. - - . .. ___. . • . - • • , .
DUARTMLNT (....',' L =,:i(..,P A.' i:....,:,!.:i,..:::.) • w
a
,. .
REGISTERED AS PROVIDED BY LAW AS
•
1 U) O
CONST CONT GENERAL
I CO W •
REGIST. # EXP. DATE ,.
u) LL
, .
:L( CCO1 MCKIN**372N0 01/02/2004 '1 uj 0
•; EFFECTIVE DATE 08/20/1963 ! 2
... MC KINSTRY CO g 5.
:., u_ a
5005 3RD AVE S .j: D a:
D.
PO BOX 24567
SEATTLE WA 98124-0567
.1 1
•
..
R25-U2 twit i ro
zi, ,.‘•
:1 ILI u
' g '
2 D:
CI
0 u);
°J..:
± 1)-0-- a. -_,L,-A-- a_t- 1
111 uj .
T AL..-4 .t11- t i2-'4 C'
CU cu '
• Z
........,,,,,,
c.).
•.- (-_,...-.„r . .p -a- 0-44- kisj 0
,, . ......
•,. ,." ' PLIn LIC
e-,
t, ':.....,,.. . . .
— o
6°.(1m
' :. ''.:I'S1-111•P'_—
- - -
i
! •
- •
•
. . -
NE‘A FM-200 PURGE
SEE DETAIL 2 ON V-2
I .,..
F—
--77: - I •
-- -. _.---_:
_a
244 FM-200 PURGE DUCT TO ROOF
0
C)
3
M- 1
hi ■• :1) PURGL FAN
SE CE 2 ON m-.2
A
REBALANCE CEILING GRILLE TO E-150 CFM
;
24"o FM-200 PURGE DUCT Ti) ROOF
•
_ I
-
_L. .
iJ
4 - 1 1 HVAt ROOF PLAN
HVAC RA PLENUM PLAN (CEILING TO ROOF)
SCALE 1/16 =
_
•
THESE RETURN AIR SHAFT DAMDERS ARE LOCATED ABOVE THE
CEILING AND ARE TO BE OPEN WHENEVER DOWNSTAIRS SPACE
IS TO BE CONDITIONED
THESE RETURN AIR OPENINGS IN ROOF SERVE
SECOND AND THIRD FLOOR TENANTS
C-
LOCATION OF OVERHEAD DA SEE DETAIL 4 ON
M - 2
DEMISING WALL TO CEILING PLENUM ABOVE
• „
THIS RETURN/EXHAUST AIR SHAFT IS EXTENDf.tT THROUGH
AMU SPACE
PROVIDE 2-POSITION RETURN AIR SMOKE (FM-200) DAMPER AT
. ...... .— ...,
I
1 ... .... :71i -'-'.
. .
1 - I ,__ .,.:-----' I • t t
• .- .-- -.11., - .Pr' - ........11111W
I ■ ..,-=;" , . : '''..
-
i_ __--_. t -_-i . • ..-_-_-_.
45.,----1 --. - ---... .--
- -•
5 ---
• .."--..".-.._
- ----- _ . .. _ i___
_ ,
_ - - _ _
_ _
_. ., ____: .___
, • ....-
• -I ' -- -- - .. - - - t
_
1 I::: - _ . - - : - - - -
,--
1= —
1 -
i _-______,!::--._ ,=== --- -.I- - -- -____ _,___
_ I
:
- - _ = L - 7_AZ3
1 -- ---. —
r
,
-_ •12.1 .____, - •
_ .
1.?:
_ = . -__
[
.
-...4.,.
,_ ___ ____
,
--: i_ _ _=_ _77 _ 7
. ' .
- --
1 • - ___
•. 4 ----"=
• - --,-., T • -
_
t.-- i ---- • ---. T --- - t-----
_-__, .
, V - -- --
' 1 -
- 1= =
iiii
•
•
•
•
• —
• • •
•-•
r __
-. 1
"n44,4 Otksosp (,sb.*) PHASE 1. e 'Eckit‘V cocidAaftwire"Altriths
Szlo o f Lt.: 0 s4put
R; wc a b er %F luj i x eLCIt4. 1.14 1,J5 pmss ,Shur Itukasi
s.k5
DA,wyPergt. Foe. Fm-Zoo SOrtibi
;
•
-:---
-- IU
•
111t,r1 7
' ; • ..._
I
REMOVE SHORT (NORTH SOUTH) BAFFLES SOUTH OF GRID 9 IN
ORDER TO ALLOW TWO ZONES TO SERVE EACH BAFFLED WAMU
SPACE AS A MEASURE OF REDUNDANCY
:
_ IZI
•
r-
•
I •- 11 4 :1 1 .1 -1-
F—.
. -HEE
•
I - -
-:--
•
4 1 ,
r _ — _
•
,
1_1_1;1_1 T.
•
__ _
- - - -
L
I 7
LZ1
:_,. . ,
i __
' i,
i, ;
U H •
. . E_
..,_ i:„,. r
' • - --ro -0--
,
I : --1
II. • . _________c
_______ r __, c ,
FOR :A SJPE' SOFT SEPANC THiRr. FLOOR, PRO'i'DE A
NE* SaVi..i 200) NUPE' SPRILIV:,-RE
2-ROSiT■00, ACTUATOR. 1200.: SEE DETA:_ 3 Oh u _
I • <.%. / N; -
PRCril: 48 "x4E TRAK' 0% rROI,
CEILihC EGGCRATE TO 24 FM-20C EPAAr• ..:1
_
_ _
.
_:_:= : 7 ' -77 7 17 7 = -
%AI = -
gr.
-----
- -- •
-
- - - - • I r
ra —
REMOVE BAFFLES NORTH OF GRID 9 AFTER
TEMPORARY PHASE I.
I_
1.
YJRiD P4ASE TEMPO RAR- r.:ONSTR...CTOk [M/OP RFTj CE:-'C GRILLES Ps HAT:CH1.3 AREAS J 1,0; 0. _
:RA; • SPEE 7 . , BE *-- _E CE,L1h:
coi::LcTo DfB FROM CIRCUAT
-
_ _
7 7 . Lz, - 177
-
-
• — F F. 1
. • - ,
_ .
1 7
1E1 - - - • TT
1 113;1
.
__ r
L E .
:121 _27f -R • 12n
:
- --t , _ ,
_ _ _ -
r - - _
- • • --
--- • - • of.= -- --------- _
.-- •
- - -----------
F - z- 1:74 T7 -
•
-
- -
DURING PHASE I TEMPORARY CONSTRUCTION, REMOVE OR
CLOSE AL PERFORATE C. TILES IN HATCHED AREAS. THIS
IviLL ALLOW TEMPORARY Sf-' TO BE COOLED AIR
COMING FROM THESE SIX SUPPLY SHAFTS_
2 HVAC CEILING PLAN RAISED FLOOR TO CEILINGI REN/i31C<A'43
EACH OF (9 4 x 8' RETURN OPENINGS SEE DETAIL 1 ON SCALE: I/16' = I'-0' N'71 BE PAAIr TO
P.- 1 PP! OP,
FILE= COPY
I PICT C.The. , rcva;', - -_ , are
.:TSC•2 , . .• 17y
‘.:,:ks, Cod of c
trac.: S cy of 3i:r.p! pUnS
• •
tv0- 4/
M _ . +i -
• • -•
• _t.
.
-,--14. I .t
_
_t__
•
• • '
. 1 t
• .
9 HVAC SUPPLY SHAFTS SERVING WAMU SPACE
THEIR DAMPERS CLOSED DURING PHASE 1
.,,__. _ _ I '7.4 . -4-■._ 4- _._._
, I
. .... .__. . . . ..__,_L-L_
• -
4 . 4 _■ --._ .
-,-
.1 - . h.. . . . •
... ztr
.,...._. _ •
A
- • .; • • • • • •
:— • • - .
HVAC'fLOOR PL i FLOOR)
(EOUIPWEHT ABOVE FLOOR SHOWN FQ R REFERENCE ONLY) SCALE 1/16' =
• 4
LOCATION OF UNDERFLOOR DAMPER SEE DETAR 4 /
ON M-2
- OKAii-A BUILDING DIVIC
You poultE A KW PLAN 8
A..; MAY '&T41 euv■ RC•irk FEES
I
WI
Cate
Permit No _1
2 04
. • .
- -1
-1- •
•
• --. • • -
1.
_ -
- — -
4-- 4 • ■
-
voce‘
-J.-. *TT_ : : •
• " _
----
-
_1
7 _1PEIIIL, /
•
. _ .
•- • - •
. ' .
•
' 4
SEP 1 3 2002
/170?-/89
M-1
F EREs.: 05-fl-03
EPARATE PER11.:IT
REQUIRED FOR;
;FLANCAL
[
PLUMBING
D GAS PIPING
CITY OF TUKWILA
:1OILD!NG DVSION
PERmit ISSUE
HVAC PLANS
3RD FLOOR WAMU
a_ •
PERMIT ISSUE
SEPTEMBER 11, 2002
cr,
Cr•
11SEPT02
t
G
t
PCV!DE PERFORATED FLOOR 'i_E
Ih 'HS AREA
4
M -2
NO SCALE
PRCAIDE 24' 5:�.,AE UNDJCTED :C406PiA SYLA : ANC ;RE
DAMPER 1 .14, �CJR CLASS i:', w - SHOMN DN PLANS 9E.,',*
/FLOOR (SUPP_ 1 ANC, A&SC CEILtiS �A►
,RET:., CONSUL TC
BULDP G cPE ALARM SYSTEM B` OTHERS
NE* RATEC CORRIDOR "JNN CONS"'?: "TION B`:' G.C.
HVAC FOR RATED CORRIDOR
UNIT
MARK
GE 1 -1 ToP_
H' E. , 1 HR _
1 y�
1
MF
5. PROVIDE GALV. BURGLAR BARS.
MODEL
v! 7 E 4
A
DESIGN
CFM
7. CONTRACTOR MAY SUBMIT ANOTHER APPROVED OR EQUAL MANUFACTURER.
NOMNA_ 32' X 68 CL_ASS t! S1A30,E DAMPER MEETING JL 55
FOR %M -20G CONTAINMEN' PRUDE 120v NORMALLY CL'SED 2
POSITION A - )ATOP-
PRO'VDE (ACTUATOR MOTOR; ACCESS DOOR IN_
ShAF' NA ANC IN DUCT
3
M -2
FAN _
CAPACITY TS RPM RPM :PEED LWA BHP DRIVE
CCFM)
7E. ° CLii'
Inc 7L0 120cb 9 17 •L3PEC EP
7LC 12026 9.- 3 7 2E ,P1PEC EDP
7c'5 12025 9F, 17.5 Di ! _T ❑PE='
1. ALL DISCONNECT AND STARTERS ARE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 9. PROVIDE ROOF CURB.
NOT 10 NET IDLES
L jflL GPAVITY BA5I DRArT DAMPEP, AND BIRUSCPEEL ,1. NOT U'SEP
EXHAUST FAN SCHEDULE_
1
1
1
FM -200 SUPPLY DAMPER ASSEMBLY
NO SCALE
MOTOR VFD
TYPE HP VOLTS /PH /HZ USED
❑PER
WT
LBS
4 105
1
SERVICE
DATA CENTER
DA "A CENTER
PA , TEc
IC' NL1T USED
i3 N USED
1
15. PROVIDE LOW LEAK CUL 555) 2- POSITION ISOLATION DAMPER INTERLOCKED VIA STARTER
CONTROLS
BLDG MANAGEMENT S STET
0 L1110 MANAGEMENT SYSTEM
if-.C1 MANAGEMENT _"STEM
BLDG MANAGEmENI STEM
s'
1 1
M 2 NC SCALE
1
EDAM GASKET
UN TUP OF CURB
INSTALL ISOLATION DAMPER \
INSIDE ROOF CURE
OR DUCT, PROvIC 5 ACCESS
FOR DAMPER AC
FACTOR'
CURB
6X4 FIRE RETARDAN
LEVELING URE.
CONTRACTOR HAS
OPTION '0 USE STEEL
R❑ ❑F ING-\
2
M -2
CEILING
'
NO SCALE
24' 5 48 EGO CRATE GR E
4
SEE NETES
8e .DIN EDP 4r T
PEF -1, PEF -2 GREENHECK TAUB -30 3.3 AC /HR 9,000 0.5 1300 10210 2.29 BELT ODP . 2.0 460/3/60 NO 390 FM -200 PURGE EXHAUST
:AGE E M
LOCAL MANUAL STARTER
3,4,5,7 & 9
YEJ S111P_u16 ' i`eEIC i+-E AKr
QAC�DR71M. ".! 1E304 PIPE ;€?:L 5 MCA 3^ 5JIw :'STE!IF ti
POSITION DDC SENSORS ON ROOM SIDE OF DAMPER. ABOVE EGGCRA:E
FM -200 RETURN DAMPER ASSEMBLY
L
BURGJLAR BARS
MOUNTED IN ROOF
OPENING
BOLD TEXT REPRESENTS DRAWINGS CHANGES MADE FOR THIS CURRENT REVISION.
I4ev:. 24' 1 48' C:ASS i SIGs; CAi - miry, .._ 555
c...ftlf tC SUP MCA ESC CRAT PRO,D1E 120v
k W.. - xca✓ 2 PQSTtOh
FM -200 PURGE FAN INSTALLATION
XHAUST FAN
VFD ■/rUSED DISCONNECT
IN NEMA 3P CABINET
vE NTED ON FAN OR PALK
B ELECTRICAL
RECEIVEL
cIv or- Tukw,L.
SEP 1 3 2002
PERMIT CE4TER
M•2
PERMIT ISSUE
SEPTEMBER 11, 2002
HVAC DETAILS
3RD FLOOR WAMU
P'[RM'T ISSUE ___ 11SEPT02