Loading...
HomeMy WebLinkAboutPermit M02-184 - WASHINGTON MUTUAL - DATA CENTER PHASE IWASHINGTON MUTUAL DATA CTR PHASE 1 3355 S 720x" PL M02 -184 re LI 0 co W F Nu. WD Q. .a zF 1- O z� uj co 0- a.F- WW -. w Z UF City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Tenant: Name: WASHINGTON MUTUAL DATA CENTER Address: 3355 S 120 PL, TUKWILA WA Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL, SEATTLE WA Contact Person: Name: DAVID HOWE Address: 5005 3 AV S, SEATTLE, WA Contractor: Name: MCKINSTRY COMPANY Address: 5005 3 AV S, PO BOX 24567 Contractor License No: MCKIN* *372ND Permit Center Authorized Signature: doc: Mech komAif MECHANICAL PERMIT Permit Number: MO2 -184 Issue Date: 09/25/2002 Permit Expires On: 03/24/2003 Phone: Phone: 206 832 -8214 Phone: 206 762 -3311 Expiration Date: 01/02/2004 DESCRIPTION OF WORK: INSTALL RETURN AIR GRILLES AND CONTROL DAMPERS IN THE CEILING AND SUPPLY SHAFTS. THE DAMPERS ARE REQUIRED TO CONTAIN FM -200 FIRE SUPPRESSION AGENT UPON DISCHARGE. Value of Construction: $15,000.00 Fees Collected: Type of Fire Protection: Uniform Mechnical Code Edition: Date: 9 5- $263.31 1997 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating con or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: �I`j(, d lkJ9C4l CJ Date: ` Print Name: '1�1� - � Li LAY ) e This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. MO2 -184 Printed: 09 -25 -2002 z ✓ 0 W w LL WW Q u. Nd y W z � O uj w O ▪ � O. H w H -- LL z co O 1 ' z doc: Conditions City of Tukwila • PERMIT CONDITIONS MO2 -184 Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1023049069 Permit Number: MO2 -184 Address: 3355 S 120 PL TUKW Status: ISSUED Suite No: Applied Date: 09/13/2002 Tenant: WASHINGTON MUTUAL DATA CENTER Issue Date: 09/25/2002 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 5: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 6: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 7: Manufacturers installation instructions required on site for the building inspectors review. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: 6-T LA A VI (:)A--) Date: q— 2 Print Name: - J c/L J Printed: 09 -25 -2002 Pr I j • ct Name/Tenant: . .. P i se � Value of Mechanical Eq�l`pment: CO-). c Fax Fax #: IOC S3 _ goy Site Address City 355 SNl 1 place. < l�u�;la� GOhW 1tS$ Tax Parcel Number: loz�o� - ,. Phone: ( j6') I - g 700 Property Owner: Street Addres �/ City Statg/,7,i 122 0 1 -1 N ct +31. Mol y )r i/x 1 j a r td A 1�' Fax #: (7js ze 2 _ .9,5--1 Co tract m e ICI v• 4 CO wip Phone: ( ■ ) S� t C, o � ess: 3,c 1 Alm. si coi)— 9,1 ity S te/Zip: Fax #: ( 70 6i 7G — 3. .41 C ot}tac Perso ��� Phone: ) 6 I Stre�et A � d e c � e s s : . �i egl ,3,0414) ve— r „City State/Zip: Ie... t LA___ 1 Z l/ Fax #: (7_06) a O3z —S6' 1 y BUILD/NGIO R :O ' A' TH RIZED AGENT :. .... : :: ,'!''!!' 'i ° Signature: Date: c /t3 10 Print name: 0.0 I O MAX-- Phone: (206 ) g 32 _ g 2 , Fax Fax #: IOC S3 _ goy Address: SDo s 3c.,„\ Ave._ ` Cit /State/Zip r 0'12'L/ CITY OF 7 'KWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Number: /70,2—el R STA(( USE UNI Y Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. 1� v �►� fi Iv■ Pti i ECHANICALPERi'vMIT .REVIEW AND APPROVAL REQUESTED: (TO BE °FILLED :OUT BY APPLICANT)'` Description of work to be done (please be specific): 1 ) Re LAYin Ai r Gr% IkS cAhd coy4j ) nee. -s Irk - fie, ce_h1;n 10)/ S Ja S. �- cavnpefs e r c n 'r 1 ) - Z-00 e_ Stn p � � � v,V1i) sL 7� 0 'hot R � r � � o rSG ( (fess(dh &% f' r r}� �a r'ye , Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: 5 /3 -. Application taken by: (initials) 11/2/99 rucch penult doe II .60 A ., Submittal Requirements Floor plan and system layout p MI c b t'lo r cr4 y N __Tyi _Roof plan required to identify individual equipment an the location of each installation (Uniform Mechanical Code 504 (e)) AI rba1 tub V k N A-Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 I\f t) ep�lo r i - H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with"smokJdetection shut - -off and will be routed to the Fire Prevention division for additi nal com 'nts (Uniform M chanical ‘ Code 1009). o '( ✓ s ` ,t S d 00 0 C,- i� 5',110 A dec 4 ivrt. 1 S N Specifications must be provided to show that replacement equipment complies with the eff ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Adio u i , Nr .-4- Structural engineer's analysis is required for new and the replacement•of existing roof equipmen U weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. M p eynu j,. 3 - Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal ti RESIDENTIAL: Two complete sets of attachments required with application submittal Change - out or replacement of existing mechanical equipment Narrative of work to be done, including modification to duct work. 11/2/99 miscpml.doc New Single Family Residence Installation of Gas Fireplace NOTE: Water heaters and vents are included in the Uniform Mechanical Code - please include any water heaters or vents being installed or replaced. i?r Submittal Requirements Heat loss calculations or Form H -6. Equipment specifications. Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code - please include any water heaters or vents being installed or replaced. Or 75 '' City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 1023049069 Permit Number: MO2 -184 Address: 3355 S 120 PL TUKW Status: APPROVED Suite No: Applied Date: 09/13/2002 Applicant: WASHINGTON MUTUAL DATA CENTER Issue Date: Receipt No.: R020001407 Payment Amount: 263.31 Initials: KAS Payment Date: 09/25/2002 11:23 AM User ID: 1684 Balance: $0.00 Payee: MCKINSTRY CO TRANSACTION LIST: doe: Receipt Amount Type Method Description Payment Check 5687 263.31 ACCOUNT ITEM LIST: Current Pmts PLAN CHECK - NONRES Description Account Code MECHANICAL - NONRES 000/322.100 000/345.830 52.66 210.65 Total: 263.31 Printed: 09 -25 -2002 Project: . . - .44, 2 A4t..."17.11 Type of Inspection: ..L ,. . . .... . Date Called: Address:. •, • .... , / 2 41'11V--1— Special Instructions: :_. Date Wanted: koa 2 g — e 2 1 0 C Requester: Phone No: 4 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 7",; i" 14/11., El $47.00 ;47.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: '•• Project 11 1 4 L it \ Type of Inspection: tt c - .S.1-14 OW' — Oq w+ Address: 33,5 S S 1 ?O r 1 1 Date Called: . Special Instructions: Date Wanted: ,j - 8 - 03 a.m. P.m. Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 EI Approved per applicable codes. Corrections required prior to approval. INSPECTION RECORD Retain a copy with permit COMMENTS: Sv \ cI $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: ,a.,.. I � . • pr�ir'a (206)431 -3670 Date: P /2i6,6,/ 4,/7.? (7 ei. Type /MR.9:: Tina, Address: 3355 s i.,o /'L- Date Called• r /`I - 0.3 Special Instructions: S I_ t 1 I ' \ 1 r Date Wanted: tt�� � `�Vl. m. Request : ( rl ri Phone No: S; p», ;.:4!ilsaraft;:+:�! ✓:A;:?r F� ^.y>k�rL!s�t?s:t+� Ji L� INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 `Approved per applicable codes. Corrections required prior to approval. COMMENTS: ;/ .00 REINSPECTION at 6300 Southcente 'Receipt No.: 'Date: 1w r`1 I.. A.01/ -cam/ Date: EE REQUIRED. Pri4r to inspection, fee must be Blvd., Suite 100. Call to schedule reinspection. a4ri.a -pct.+ .n. 9 f) A Project:, - : _ i A, A.-faL 2 4 v4 - Type of Inspection: /Lc c/ - 17,/ . Address:- , ! . , .5 0 2 i 6 f';',Z Date Called: ' Special Instructions: ' - .., . . , .. Date Wanted: Ca Requester: )(.. .,,X.#4 ler - Phone No: _ ...., • . . ........ INSPECTION RECORD • Retain a copy with permit INSPE TION NO. ITY OF TUKWILA BUILDING DIVISION 300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes 4.; M22 -49e-,/ (206)431-3670 Corrections required prior to approval. COMMENTS: - r6"..i..■• J./Zoo $47.00 REINSPECTIO E REQUIRED. Prior to Inspection, fee must be paid it t 300 Southcen er Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: rew U U) co Lu 0 g "Zi u_ Lo. a g. I lij n 0 — D. Ui LU tu 0 October 7, 2003 David Howe 5005 Third Avenue South Seattle, WA 98124 RE: Permit Application No. MO2 -184 3355 South 120th Place Dear Permit Holder: City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director W i = 0 O CO LU Ncl � WO Q 2 Q LL? N d uj l-0 U� O N • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final O. '— inspection. W W t z U= O~ z In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above Inspection or request and receive an extension prior to November 4, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefanie Spencer Permit Technician Xc: Permit File No. MO2 -184 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206- 431 -3665 ACTIVITY NUMBER: MO2 -184 DATE: 09 -13 -02 PROJECT NAME: WASHINGTON MUTUAL DATA CENTER - PH 1 SITE ADDRESS: 3355 S 120 PLACE X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Buildin T ivision Q Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP lI1 Fire Prevention Structural ❑ Incomplete ❑ Planning Division Permit Coordinator DUE DATE: 09-17 -02 DUE DATE: 10 -15 -02 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUJING: Please Route E3A Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: Approved ❑ Approved with Conditions a3 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -2802 PERMIT COORD COPY Z ;',==-.4"-Z. 7 7.7:7 — . - -. - - . .. ___. . • . - • • , . DUARTMLNT (....',' L =,:i(..,P A.' i:....,:,!.:i,..:::.) • w a ,. . REGISTERED AS PROVIDED BY LAW AS • 1 U) O CONST CONT GENERAL I CO W • REGIST. # EXP. DATE ,. u) LL , . :L( CCO1 MCKIN**372N0 01/02/2004 '1 uj 0 •; EFFECTIVE DATE 08/20/1963 ! 2 ... MC KINSTRY CO g 5. :., u_ a 5005 3RD AVE S .j: D a: D. PO BOX 24567 SEATTLE WA 98124-0567 .1 1 • .. R25-U2 twit i ro zi, ,.‘• :1 ILI u ' g ' 2 D: CI 0 u); °J..: ± 1)-0-- a. -_,L,-A-- a_t- 1 111 uj . T AL..-4 .t11- t i2-'4 C' CU cu ' • Z ........,,,,,, c.). •.- (-_,...-.„r . .p -a- 0-44- kisj 0 ,, . ...... •,. ,." ' PLIn LIC e-, t, ':.....,,.. . . . — o 6°.(1m ' :. ''.:I'S1-111•P'_— - - - i ! • - • • . . - NE‘A FM-200 PURGE SEE DETAIL 2 ON V-2 I .,.. F— --77: - I • -- -. _.---_: _a 244 FM-200 PURGE DUCT TO ROOF 0 C) 3 M- 1 hi ■• :1) PURGL FAN SE CE 2 ON m-.2 A REBALANCE CEILING GRILLE TO E-150 CFM ; 24"o FM-200 PURGE DUCT Ti) ROOF • _ I - _L. . iJ 4 - 1 1 HVAt ROOF PLAN HVAC RA PLENUM PLAN (CEILING TO ROOF) SCALE 1/16 = _ • THESE RETURN AIR SHAFT DAMDERS ARE LOCATED ABOVE THE CEILING AND ARE TO BE OPEN WHENEVER DOWNSTAIRS SPACE IS TO BE CONDITIONED THESE RETURN AIR OPENINGS IN ROOF SERVE SECOND AND THIRD FLOOR TENANTS C- LOCATION OF OVERHEAD DA SEE DETAIL 4 ON M - 2 DEMISING WALL TO CEILING PLENUM ABOVE • „ THIS RETURN/EXHAUST AIR SHAFT IS EXTENDf.tT THROUGH AMU SPACE PROVIDE 2-POSITION RETURN AIR SMOKE (FM-200) DAMPER AT . ...... .— ..., I 1 ... .... :71i -'-'. . . 1 - I ,__ .,.:-----' I • t t • .- .-- -.11., - .Pr' - ........11111W I ■ ..,-=;" , . : '''.. - i_ __--_. t -_-i . • ..-_-_-_. 45.,----1 --. - ---... .-- - -• 5 --- • .."--..".-.._ - ----- _ . .. _ i___ _ , _ - - _ _ _ _ _. ., ____: .___ , • ....- • -I ' -- -- - .. - - - t _ 1 I::: - _ . - - : - - - - ,-- 1= — 1 - i _-______,!::--._ ,=== --- -.I- - -- -____ _,___ _ I : - - _ = L - 7_AZ3 1 -- ---. — r , -_ •12.1 .____, - • _ . 1.?: _ = . -__ [ . -...4.,. ,_ ___ ____ , --: i_ _ _=_ _77 _ 7 . ' . - -- 1 • - ___ •. 4 ----"= • - --,-., T • - _ t.-- i ---- • ---. T --- - t----- _-__, . , V - -- -- ' 1 - - 1= = iiii • • • • • — • • • •-• r __ -. 1 "n44,4 Otksosp (,sb.*) PHASE 1. e 'Eckit‘V cocidAaftwire"Altriths Szlo o f Lt.: 0 s4put R; wc a b er %F luj i x eLCIt4. 1.14 1,J5 pmss ,Shur Itukasi s.k5 DA,wyPergt. Foe. Fm-Zoo SOrtibi ; • -:--- -- IU • 111t,r1 7 ' ; • ..._ I REMOVE SHORT (NORTH SOUTH) BAFFLES SOUTH OF GRID 9 IN ORDER TO ALLOW TWO ZONES TO SERVE EACH BAFFLED WAMU SPACE AS A MEASURE OF REDUNDANCY : _ IZI • r- • I •- 11 4 :1 1 .1 -1- F—. . -HEE • I - - -:-- • 4 1 , r _ — _ • , 1_1_1;1_1 T. • __ _ - - - - L I 7 LZ1 :_,. . , i __ ' i, i, ; U H • . . E_ ..,_ i:„,. r ' • - --ro -0-- , I : --1 II. • . _________c _______ r __, c , FOR :A SJPE' SOFT SEPANC THiRr. FLOOR, PRO'i'DE A NE* SaVi..i 200) NUPE' SPRILIV:,-RE 2-ROSiT■00, ACTUATOR. 1200.: SEE DETA:_ 3 Oh u _ I • <.%. / N; - PRCril: 48 "x4E TRAK' 0% rROI, CEILihC EGGCRATE TO 24 FM-20C EPAAr• ..:1 _ _ _ . _:_:= : 7 ' -77 7 17 7 = - %AI = - gr. ----- - -- • - - - - - • I r ra — REMOVE BAFFLES NORTH OF GRID 9 AFTER TEMPORARY PHASE I. I_ 1. YJRiD P4ASE TEMPO RAR- r.:ONSTR...CTOk [M/OP RFTj CE:-'C GRILLES Ps HAT:CH1.3 AREAS J 1,0; 0. _ :RA; • SPEE 7 . , BE *-- _E CE,L1h: coi::LcTo DfB FROM CIRCUAT - _ _ 7 7 . Lz, - 177 - - • — F F. 1 . • - , _ . 1 7 1E1 - - - • TT 1 113;1 . __ r L E . :121 _27f -R • 12n : - --t , _ , _ _ _ - r - - _ - • • -- --- • - • of.= -- --------- _ .-- • - - ----------- F - z- 1:74 T7 - • - - - DURING PHASE I TEMPORARY CONSTRUCTION, REMOVE OR CLOSE AL PERFORATE C. TILES IN HATCHED AREAS. THIS IviLL ALLOW TEMPORARY Sf-' TO BE COOLED AIR COMING FROM THESE SIX SUPPLY SHAFTS_ 2 HVAC CEILING PLAN RAISED FLOOR TO CEILINGI REN/i31C<A'43 EACH OF (9 4 x 8' RETURN OPENINGS SEE DETAIL 1 ON SCALE: I/16' = I'-0' N'71 BE PAAIr TO P.- 1 PP! OP, FILE= COPY I PICT C.The. , rcva;', - -_ , are .:TSC•2 , . .• 17y ‘.:,:ks, Cod of c trac.: S cy of 3i:r.p! pUnS • • tv0- 4/ M _ . +i - • • -• • _t. . -,--14. I .t _ _t__ • • • ' . 1 t • . 9 HVAC SUPPLY SHAFTS SERVING WAMU SPACE THEIR DAMPERS CLOSED DURING PHASE 1 .,,__. _ _ I '7.4 . -4-■._ 4- _._._ , I . .... .__. . . . ..__,_L-L_ • - 4 . 4 _■ --._ . -,- .1 - . h.. . . . • ... ztr .,...._. _ • A - • .; • • • • • • :— • • - . HVAC'fLOOR PL i FLOOR) (EOUIPWEHT ABOVE FLOOR SHOWN FQ R REFERENCE ONLY) SCALE 1/16' = • 4 LOCATION OF UNDERFLOOR DAMPER SEE DETAR 4 / ON M-2 - OKAii-A BUILDING DIVIC You poultE A KW PLAN 8 A..; MAY '&T41 euv■ RC•irk FEES I WI Cate Permit No _1 2 04 . • . - -1 -1- • • • --. • • - 1. _ - - — - 4-- 4 • ■ - voce‘ -J.-. *TT_ : : • • " _ ---- - _1 7 _1PEIIIL, / • . _ . •- • - • . ' . • ' 4 SEP 1 3 2002 /170?-/89 M-1 F EREs.: 05-fl-03 EPARATE PER11.:IT REQUIRED FOR; ;FLANCAL [ PLUMBING D GAS PIPING CITY OF TUKWILA :1OILD!NG DVSION PERmit ISSUE HVAC PLANS 3RD FLOOR WAMU a_ • PERMIT ISSUE SEPTEMBER 11, 2002 cr, Cr• 11SEPT02 t G t PCV!DE PERFORATED FLOOR 'i_E Ih 'HS AREA 4 M -2 NO SCALE PRCAIDE 24' 5:�.,AE UNDJCTED :C406PiA SYLA : ANC ;RE DAMPER 1 .14, �CJR CLASS i:', w - SHOMN DN PLANS 9E.,',* /FLOOR (SUPP_ 1 ANC, A&SC CEILtiS �A► ,RET:., CONSUL TC BULDP G cPE ALARM SYSTEM B` OTHERS NE* RATEC CORRIDOR "JNN CONS"'?: "TION B`:' G.C. HVAC FOR RATED CORRIDOR UNIT MARK GE 1 -1 ToP_ H' E. , 1 HR _ 1 y� 1 MF 5. PROVIDE GALV. BURGLAR BARS. MODEL v! 7 E 4 A DESIGN CFM 7. CONTRACTOR MAY SUBMIT ANOTHER APPROVED OR EQUAL MANUFACTURER. NOMNA_ 32' X 68 CL_ASS t! S1A30,E DAMPER MEETING JL 55 FOR %M -20G CONTAINMEN' PRUDE 120v NORMALLY CL'SED 2 POSITION A - )ATOP- PRO'VDE (ACTUATOR MOTOR; ACCESS DOOR IN_ ShAF' NA ANC IN DUCT 3 M -2 FAN _ CAPACITY TS RPM RPM :PEED LWA BHP DRIVE CCFM) 7E. ° CLii' Inc 7L0 120cb 9 17 •L3PEC EP 7LC 12026 9.- 3 7 2E ,P1PEC EDP 7c'5 12025 9F, 17.5 Di ! _T ❑PE=' 1. ALL DISCONNECT AND STARTERS ARE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 9. PROVIDE ROOF CURB. NOT 10 NET IDLES L jflL GPAVITY BA5I DRArT DAMPEP, AND BIRUSCPEEL ,1. NOT U'SEP EXHAUST FAN SCHEDULE_ 1 1 1 FM -200 SUPPLY DAMPER ASSEMBLY NO SCALE MOTOR VFD TYPE HP VOLTS /PH /HZ USED ❑PER WT LBS 4 105 1 SERVICE DATA CENTER DA "A CENTER PA , TEc IC' NL1T USED i3 N USED 1 15. PROVIDE LOW LEAK CUL 555) 2- POSITION ISOLATION DAMPER INTERLOCKED VIA STARTER CONTROLS BLDG MANAGEMENT S STET 0 L1110 MANAGEMENT SYSTEM if-.C1 MANAGEMENT _"STEM BLDG MANAGEmENI STEM s' 1 1 M 2 NC SCALE 1 EDAM GASKET UN TUP OF CURB INSTALL ISOLATION DAMPER \ INSIDE ROOF CURE OR DUCT, PROvIC 5 ACCESS FOR DAMPER AC FACTOR' CURB 6X4 FIRE RETARDAN LEVELING URE. CONTRACTOR HAS OPTION '0 USE STEEL R❑ ❑F ING-\ 2 M -2 CEILING ' NO SCALE 24' 5 48 EGO CRATE GR E 4 SEE NETES 8e .DIN EDP 4r T PEF -1, PEF -2 GREENHECK TAUB -30 3.3 AC /HR 9,000 0.5 1300 10210 2.29 BELT ODP . 2.0 460/3/60 NO 390 FM -200 PURGE EXHAUST :AGE E M LOCAL MANUAL STARTER 3,4,5,7 & 9 YEJ S111P_u16 ' i`eEIC i+-E AKr QAC�DR71M. ".! 1E304 PIPE ;€?:L 5 MCA 3^ 5JIw :'STE!IF ti POSITION DDC SENSORS ON ROOM SIDE OF DAMPER. ABOVE EGGCRA:E FM -200 RETURN DAMPER ASSEMBLY L BURGJLAR BARS MOUNTED IN ROOF OPENING BOLD TEXT REPRESENTS DRAWINGS CHANGES MADE FOR THIS CURRENT REVISION. I4ev:. 24' 1 48' C:ASS i SIGs; CAi - miry, .._ 555 c...ftlf tC SUP MCA ESC CRAT PRO,D1E 120v k W.. - xca✓ 2 PQSTtOh FM -200 PURGE FAN INSTALLATION XHAUST FAN VFD ■/rUSED DISCONNECT IN NEMA 3P CABINET vE NTED ON FAN OR PALK B ELECTRICAL RECEIVEL cIv or- Tukw,L. SEP 1 3 2002 PERMIT CE4TER M•2 PERMIT ISSUE SEPTEMBER 11, 2002 HVAC DETAILS 3RD FLOOR WAMU P'[RM'T ISSUE ___ 11SEPT02