City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
CERTIFICATE OF OCCUPANCY
t i
Permit No.: D02 -330 - d `
w
Y
Z �.
O
z
w
2 o
U
O -
0 I-
w W
u.
Occupancy: 0020 Occupant Load: 72 w Z
Occupancy Group: A -3 (Restaurant) Type of Construction: VN (sprinklered) 17-
This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code, 1997 Edition,
certifying that at the time of issuance this structure was in compliance with the various ordinances of the City
regulating building construction or use for the following:
Occupant /Tenant: THAI MALI CUISINE
Building Address: 17310 SOUTHCENTER PY TUKW
Parcel No.: 2623049079
Property Owner: MBK NORTHWEST DEPT 436
Signatur of Building O icial
D02 -330
�'- 30 - 2003
Date
THIS CERTIFICATE MUST BE CONSPICUOUSLY POSTED ON THE PREMISES
Printed: 09 -30 -2003
i
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Signature:
Print Name:
doc: Mech
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
2623049079
17310 SOUTHCENTER PY TUKW
Permit Center Authorized Signature:
THAI MALI CUISINE
17310 SOUTHCENTER PY, TUKWILA, WA
MBK NORTHWEST DEPT 436
P 0 BOX 34935, SEATTLE WA
THOMAS LI
16022 12 AV SW, BURIEN WA
Contractor:
Name: MUTUAL INDUSTRIES INC
Address: 9832 17TH AVE SW, SEATTLE WA
Contractor License No: MUTUAI1041 D5
MECHANICAL PERMIT
Permit Number:
Issue Date:
Permit Expires On:
Phone: 503 636 -2800
Phone: 253 973 -8500
Phone: 206 - 767 -6647
Expiration Date: 02/20/2003
DESCRIPTION OF WORK:
INSTALL A COMMERICAL KITCHEN HOOD (TYPE 1; 2 EXHAUST FANS, 2 MAKE -UP AIR FANS
AND A DUCT SYSTEM
MO2 -210
12/24/2002
06/22/2003
Value of Construction: $7,000.00 Fees Collected: $51.75
Type of Fire Protection: SPRINKLERS Uniform Mechnical Code Edition: 1997
Date: y
thereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not .res ine to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or the - r 6r; a of work. I . . uthorized to sign and obtain this mechanical permit.
Date: kr - 9-41, - 24922_
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
MO2 -210 Printed: 12 -24 -2002
1
\r1
i
S
1
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
PERMIT CONDITIONS
Parcel No.: 2623049079 Permit Number: MO2-210
Address: 17310 SOUTHCENTER PY TUKW Status: ISSUED
Suite No: Applied Date: 10/29/2002
Tenant: THAI MALI CUISINE Issue Date: 12/24/2002
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division.
3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be
inspected by that agency, including all gas piping (296- 4722).
4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical
work will be inspected by that agency (206- 835 - 1111).
5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any
construction. These documents are to be maintained and available until final inspection approval is granted.
6: Readily accessible access to roof mounted equipment is required.
7: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear
identification showing the fire performance rating thereof.
8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997
Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition).
9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be
construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any
other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this
code shall be valid.
10: Manufacturers installation instructions required on site for the building inspectors review.
11: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform
Building Code and the Washington State Ventilation and Indoor Quality Code, Chapter 51 -13 WAC.
12: ** *FIRE DEPARTMENT CONDITIONS * **
13: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following
concerns:
14: Commercial -type food heat - processing equipment from which grease -laden vapors emanate in normal cooking application
shall be protected by an approved automatic extinguishing system. The extinguisher system shall be interconnected to
the fuel and current supply so that the fuel or current is automatically shut off to all equipment under the hood, when
the system is actuated. (UFC 1006)
15: Local U.L. central station supervision is required. (City Ordinance #1900)
16: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC
1001.3)
17: All new automatic fire - extinguishing systems and all modifications to exsting automatic fire - extinguishing systems
shall have fire department review and approval of drawings prior to installation or modification.
18: A wet chemical portable fire extinguisher having a minimum rating of 2A:1B:C:K shall be installed within 30 feet of
commercial food heat - processing equipment, as measured along an obstructed path of travel. (UFC 1006.2.7).
19: Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or
wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with
the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more
than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less
than 4 inches.
20: Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be
identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 106.3) (UFC Standard
10 -1)
doc: Conditions
MO2 -210
Printed: 12 -24 -2002
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
21: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5)
22: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance
#1900 and #1901)
23: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
24: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
2
VO
N D
�W
N W
WO
u.
The granting of this permit do ::s n. presume to give authority to violate or cancel the provision of any other work or local laws ie d :
regulating constructio or the -rformance of work. W
Z
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
doc: Conditions
Signature:
Print Name: L
MO2 -210
Date:
2 D.
CI I—
W W'
V Z:
E=-
O~
Z
Printed: 12 -24 -2002
Project Name /Tenant: —DQ � � ;
//(a 41A; .$14 e.-
Value of Mechanical Equipment:
� p o0
Site Address : City State/Zip:
/ 73L,z - covr�. PP A/ura✓.44- ofi i9ez.6
Tax arcel Number:
z - 3d� - ra79 -off
Property O ner; No rr
n f+
Phone: ( ) /! d v
� — D
Street Address: State/Zip:
¥ 4 7 A)I ens Q( o r 0 it 10
Fax #: ( )
(/��
Contractor:
/i'rw? ,( /noicds'jf 4 /*c Ail
P ( ,)
1
zdG ? -6
10--,5/1
J City S p:
Street Andre `7 7/
!T Gfl
Fax #: ( )
Contact Person:
m a s L- l
Phone: ( )
X03 - 173 -89
Street Address: + _cit wk ip:
Fax #: ( )
Fax #:
BUILDING OWNER
R AUTHORIZED AGENT:
Signature:
-
(/��
Date: / D
v
Print name:
Phone: (
Fax #:
Address:
60z.�
....p
n
L
E, 7
City / State/Zip: art
� j
', !^ �fcg / I
N/ /'t / 0
CITY OF — JKWI LA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
Mechanical Permit Application
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
•'MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT)
Description of work to be done (please be specific): A
/45 *- .// Gb m ere :'mil ra e n /4 l ArX/O -)
‹
Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of
application, a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor
Registration ".
Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the
State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the
permit will be required as part of this submittal.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written
request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be
extended more than once.
Date application accepted:
/ ' 27-02—
09/10/2002
Date application expires:
Application taken by: (initials)
/(-s
✓
.,/
Submittal Requirements
Floor plan and system layout
Roof plan required to identify individual equipment and the location of each installation (Uniform
Mechanical Code 504 (e))
Details and elevations (for roof mounted equipment) and proposed screening .
Heat Loss Calculations or Washington State Energy Code Form #H -7
H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut-
off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical
Code 1009).
Specifications must be provided to show that replacement equipment complies with the efficiency ratings
and other applicable requirements of the Washington State Nonresidential Energy Code.
Structural engineer's analysis is required for new and the replacement of existing roof equipment
(including commercial kitchen hoods) weighing 400 pounds and greater (Uniform Building Code
1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer.
Mechanical Permits
COMMERCIAL: Two complete sets of drawings and attachments required with application submittal
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced.
RESIDENTIAL: Two complete sets of attachments required with application submittal
Submittal Requirements
New Single Family Residence
Heat loss calculations or Form H -6.
Equipment specifications.
Change - out or replacement of existing mechanical equipment
I Narrative of work to be done, including modification to duct work.
Installation of Gas Fireplace
Narrative with specification of equipment and chimney type.
If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe
condition.
09/10/2002
misrpw:t.doc
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced.
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 2623049079 Permit Number: MO2 -210
Address: 17310 SOUTHCENTER PY TUKW Status: APPROVED
Suite No: Applied Date: 10/29/2002
Applicant: THAI MALI CUISINE Issue Date:
Receipt No.: R020001785 Payment Amount: 51.75
Initials: SKS Payment Date: 12/24/2002 12:12 PM
User ID: 1165 Balance: $0.00
Payee: MUTUAL INDUSTRIES
TRANSACTION LIST:
ACCOUNT ITEM LIST:
doc: Receipt
Current Pmts
Amount
MECHANICAL - NONRES
PLAN CHECK - NONRES
Type
Payment Check 16666
RECEIPT
Method Description
51.75
Description Account Code
000/322.100 41.40
000/345.830 10.35
Total: 51.75
69i 12/24 97.16 TOTAL 51.75
Printed: 12 -24 -2002
1
Project:, e
Lc , NA ) /
Type of Inspection:
/ )-
Address.
Date Called:
Special I structions: `
� 9 iY
25 .3-70?-3985
Date Wanted:
J / ��
Requester:
C t
Phone No:
x
Inspec
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
COMMENTS:
77;
/mho
PERM
N
(2 1 6)431 -3670
pproved per applicable codes. Corrections required prior to approval.
Date:
$47. EINSPECTIOt'FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
ze
Project: j
my 4
Type of
-7(i.et
Address:
Date Called:
Special ns ructions:
1
Date Wanted
���
a.m
Requester:
Phone No:
Z
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMI
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
D Approved per applicable codes.
COMMENTS: 1 rae'0-7
1 !
Inspector:
4 4 /l n' 1 Date57 $4700 R INSPECTION FEE EQUIRED. Prior to inspection, fee s be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
'Receipt No.:
'Date:
,x/02 -- 0
Corrections required prior to approval.
Project: .
11 1 YYiat,;
of Inspection: -
'rail/vim/9 1.l 6
Date Called: I- a,7-0a
Address: /7 /
Special Instructions:
i
Date Wanted: a.m.
/2 — 3b-0,2
Requester:
�
Phone N ; : s 3 q 3- gCD o
INSPECTION RECORD
Retain a copy with permit
.kr:t.!ov; ,r,c�stc. +: ",':ai 8:'ri:�,✓.�.:::5.i:di,;.n� :ii :. a7. , ;:+t;;x...r
INSPECT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
COM ENTS:
.,
<.►7 tom_
Approved per applicable codes. E1 Corrections required prior to approval.
Inspector
$47.00 REINS* or ON FEE R QUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
f.I
COMMERCIAL KITCHEN HOOD WORK SpEET! CHECK LIST
•
Two copies of this worksheet/checklist must accompany plan sets submitted with commercial kitchen range hood
permit applications. It explains and organizes information needed' by the Department of Construction and Land
Use to efficiently review plans and issue permits. DCLU will keep this document as part of the permanent project .
file and will use it to verify code compliance. The applicant is responsible for assuring the accuracy and consis -. .
tency of the information. 044' , / � &HS ' •
A. Project Address: /1 1 O �oti7/+ C rre Z KI ` , 7
B. Established use and history of building
Is it an existing restaurant, food processing area or food service area? n Yes
If no, provide .construction or change of use permit number
C. Location of exterior ductwork and mechanical equipment
1. Is ductwork or mechanical equipment located outside of building other than roof top? I I�1 I Yes 0 No
2. Applicant shall provide plan and elevation views showing ductwork, duct enclosure, hood, cooking
surface air supply, exhaust system, and equipment support system including structural framing detail
(Examples_1, 2, and 3).
D. Type of Hood
.1. For grease and smoke removal: Type 1 Quantity
(Example: deep fryer, charbroilers, grill and roasting ovens)
2. For.steam, vapor, heat or odor removal: Type II
(Example: steamer, pastry and pizza'oven).
Hood shall have a permanent, visible label identifying it as a
•
3. Is hood for solid fuel cooking equipment?'
If yes, a separate.exhaust system is required._
E. Type of material and gage
Duct and Stainless Steel
PIe,ium
Hood
Galvanized Steel
TYPEIHOOD
Type of Material Gage
Min. Req. Proposed
Stainless Steel 22 Ga. Ga.
Galvanized Steel . 22 Ga. Ga. •
Flashing Stainless Steel • 22 Ga. 1
Galvanized Steel
18 Ga. Ga.
16 Ga. - lb Ga.
22 Ga. • Ga.
...NOV 1 9 2002
IBS i11
r'"
RECEIVED
:ITY OF TUKWIL
OCT 2 9 2002
PERMIT CENTER
❑ Yes
TYPE II HOOD
Gage
Min. Req.
NOT REQUIRED
August 1998
Quantity
22 Ga. Ga.
24 Ga Ga.
24._Ga. Up to 12" dia. Ga.
22 Ga. Up to 30" dia. Ga.
24 Ga. Up to 12" dia. _ Ga.
22 Ga. Up to 30" dia. Ga.
Proposed
(
Sheet 1
F , Qtrnt ity of air exhausted throuy.. the hood
Z CANOPY HOOD
Hood sh - extend beyond cooking surface
on all o • - n sides not lest than Min. 6" Proposed
Distance between tip of hood and edge of
cooking surface shall not exceed Max. 4' Proposed 4'. ft
Cooking surface area = X
Hood area (A) = X
TYPE I (N = 4 Q= . 150A =150 X . cfm.
HOOD (N,= 3or less Q= 100A =100X 30 = . cfm.
TYPE. II (N = 4 Q = 75A = 75 X cfm.
HOOD (N = 3 or less Q = 50A = 50 X = cfm.
G. Exhaust duct system
1. Applicant shall provide the specified air velocity in exhaust duct.
2. Duct size la( in. x + 4 in., .duct area = k in. x It in = i i ✓b'j J ft
144
.11fpe AirVelocity ' CFM/Duct Area (Ft')
of Hood (FPM)
Req. 150010 2500 "- l 1 ?i 611
II Recom. 500 to 2500 1 = FPM
2. Static pressure Toss
duct in. + grease fitters /extractor 1 /2 in. + other .. - in. = Total /l' . in. of H
3. Fan and Motor shalt be of sufficient capacity to provide the required air movement. Fan motor shall not
be installed within ducts or under hood. -
u�
•
- Fan make and model. Qkt .(A \ m i l l Q Q 1i HP
Static pressure . /•01
H. Exhaust outlet location
1. Exhaust outlet shall terminate above roof
Extend above roof
in
3d ft2
ft
NON - CANOPY HOOD
• in. at • . . Dp° cfm.
Distance from same or adjacent building
Distance above adjoining grade
Distance from property fine
Distance from windows and doors
Distance from: mechanical air intake
• Distance of duct above adjoining grade at alley
2. If exhaust outlet terminates at exterior wall, provide cleaning equipment.
See Director's rules 5-96.
N = no. of hood sides exposed
Q = quantity of,air
A = area of hood in ft
L = lineal feet of the front
cooking equipment surface
Q.= 300L
Q =300X. = c
Q =150L
Q = 150 X = cfm.
Proposed Air
Velocity
. 2��t� • FPM
Min. required
24 in.
10 ft.
10 ft.
10 ft.
10 ft.
10 ft.
16 ft.
❑ Yes
Sheet 2
I. Makeup air
1. Applicant shall provide makeup air not less than 90% of the exhaust. 2 oo cfm.
2. Makeup air system shall be electrically interlocked with the exhaust system, such the makeup air
system will operate when the exhaust system is in operation. Provide note on plan sheet no.
3. Makeup air shall be provided by a fan or motorized damper of sufficient capacity. Windows and door
openings shall not be used for the purpose of providing makeup air.
4. If more than 2500 cfm supplied to the space other than the hood, .provide heater capable of heating
makeup air supplied to the space to 65 degrees F
Heater model # - Input BTU Output BTU
Heater CFM AFUE
FAN . \ t i \( // ' 1 -- O 1MMOOTORIZED DAMPER
Make and model 614.-AX-4. Mgt
Static pressure VA - Q in. at fm.
Duct Dimension s latO area ___ ft
Air velocity = cfm/area . j;� %4'1 g
= t `J Dd fpm
Recommended air velocity, 500 fpm
Duct area req. = cfm/50Q fpm /500 = ft
Duct. Dimension req. =
Eff. Damper opening X
J: Slope of duct and cleanout access (1(
1. Horizontal duct less than 75' long mfr slope 1/4 in /ft proposed / '1 • in /ft
more than 75' long - min slope 1 in/ft proposed in/ft
2. Tight- fitting cleanout doors shall be provided at
every change in ductwork direction.
Total no. proposed 1
K.. Duct enclosure
1.. Ducts penetrating a ceiling, -wall or floor shall be enclosed in a duct enclosure from the point of
penetration to the outside air. A duct may only penetrate,exterior walls at locations where unprotected
openings are permitted by Table 5A of the 1997 Seattle Building Code.
• 2. . For code compliance purposes, it. is acceptable to assume that ducts penetrating concrete, brick or steel
ceilings, walls or floors shall require a 2 -hour fire- resistive duct enclosure, and for others, it shall be 1 hour.
type of Const • Min. Fire - Resistive Proposed • Proposed Material and Construction
Const. of Enclosure
F.R., II F.R. 2 hour hr. _
11,111, IV, V 1 hour . . hr. P- 5/ €114 3 - U ' 411 Ii r v tel'A wPb
3. Duct enclosures shall be separated from the duct by at least 3 and nat more than 12 inches. Proposed • ?j ' ,in: •
4. Duct enclosure shall be sealed around the duct at the point of penetration and vented to the exterior
through a weather - protected opening.'
5. Duct enclosures shall serve only one kitchen exhaust duct. -
6.. Tight-fitting access openings shall be provided at each cleanout door. Access enclosure doors shall •
• . have a fire - resistance rating equal to the enclosure. • .
L Multiple hood venting
1. Number of hoods vented by a.single duct system:
A single duct system may serve more than one hood located in the same story of the building, provided
that the interconnecting ducts do not penetrate any fire construction.
2. A hood outlet shall serve not more than a 12 -foot section of hood.
Sheet 3
M. Additional information for type I hood only:
1. Grease filters shall be installed at minimum 45 degree angle
and equipped with drip tray and gutter beneath lower edge of filters. Proposed
2. Distance between lowest edge of grease filters and cooking surface of:
Grill, fryer, exposed flame shall be not less than 2 ft. Proposed
Exposed charcoal, charbroil shall be not less than 3 -1/2 ft. Proposed
3. Type I hood and duct shall have clearances from combustible construction of:
PROTECTED
UNPROTECTED with 1 -Hour Fire -Rated Material
Hood Min. Req. 18 in. Proposed in.
Duct Min. Req. 18 in. Proposed in. •
'References
1) Seattle Mechanical Code 1997
2) Director's Rule 5 -96
3) Seattle Building Code 1997
degrees.
Min. Req. 3 in. • Proposed 3 in.
Min. Req. 3 in. Proposed 3 in.
4. Hoods less than 12 inches from ceilings or walls shall be flashed solidly.
Flashing.provided ' ❑ Yes d No Distance from ceiling 2 in., wall 3 , in.
5. All joints and seams shall be made with continuous liquid -tight weldor braze made on the external .
surface of the duct system. Vibration insulation connector may be used provided it consists of noncom-
bustible packing in a metal sleeve joint.
6. Centrifugal fans used for discharging grease exhaust shall be positioned in a bottom horizontal
discharge position only. A duct that diverts the fan discharge shall not exceed 3 times the diameter of
the fan outlets connected to the fan outlet. The duct shall be provided with an adequate drain opening
at the lowest point to permit drainage of grease to a suitable collection device.
7. Fire extinguishers. Shop drawings shall be submitted to DCLU for Fire Department approval prior to field
installation.
Sheet 4
PERFORMANCE (Elevation ft. - 0, Aitstrearn Temperature •F z 70)
Gig
Model
VOluma
(CFM)
SP (tin. WC)
FRPM
p oesw (hp.)
Moto Information
Sine (hp.)
V/CIP
Enclosure
RPM
1
CUBE -180.7
3,000
0.75
1,047
• 0.72
314
115/6011
QDP
1725
Greenheck
Pan and Ventilator
NOTES: AI dimensions shown are in units d inches
Fan weight is without accessories
DIMENSIONS
Roof Opahin0 ApAppprr0o.. Fan
(k+.) Wudpht (.)
20.5x20.5 103
•
u
14
I..
u
is
M
u
M
iAMIMtlt Cmis 1.032
30
25.3$ --- ----•.
UN•
8/27/01
20.57
1.75
JOB: Al Construction
25.67
CUBE
wow lots
3*
a'"
MARK: Phan Huy
Belt Drive Upblast Centrifugal
Roof Exhaust Pan
CONSTRUCTION FEATURES
• Aluminum housing • Backward inclined aluminum wheel • Curb cap with prspunched
moundnp halals • Mote and drives isolated m shock mounts • Drain trough • Bale
bearing motora • Adjustable motor pulley • Adjustable motor plais • Fan shaft mounted
in bale bearing pillow blocks • Bearings meet or stood temperature rating of fan •
Static resistant belts • Corrosion resistant fasteners
SELECTED OPTIONS i ACCESSORIES
Switch • Nerna -1, TOggIs Mounted & Wired
Heat Baffle
UUcUL 762 - 'Power Vint. for Rest. Eth. Appliances"
r ■� Fea
...--
im..ruamerwri:= -___. 4 MIMI= V
1112==r1W I N I III I
MINIM P�.rill.�I �.
::gg
-
1111
rr i n - ,..... •--
Ift vs
gm Mk
UN
LwA • A weighted sound power Wed. baud on ANSI
• 81.4. dNA • A weighted sound pressure lead. Weed
oe 11.5 dB ifenuslon per cone bend at 5.05. Bones
calculated using AMCA 501 et 5,01t. •
5.10
em
rP.r x.a+Kwvna r �r.
Inlet Sound Power by Octave rand
d8A
Sons
623
1,'
8 8
250
500 -
1000
2000
4000
0000'
74 ,
78
1 •
82
!
. 74
1
71.
82
( 66
78
87
14.7
Greenheck
Pan and Ventilator
NOTES: AI dimensions shown are in units d inches
Fan weight is without accessories
DIMENSIONS
Roof Opahin0 ApAppprr0o.. Fan
(k+.) Wudpht (.)
20.5x20.5 103
•
u
14
I..
u
is
M
u
M
iAMIMtlt Cmis 1.032
30
25.3$ --- ----•.
UN•
8/27/01
20.57
1.75
JOB: Al Construction
25.67
CUBE
wow lots
3*
a'"
MARK: Phan Huy
Belt Drive Upblast Centrifugal
Roof Exhaust Pan
CONSTRUCTION FEATURES
• Aluminum housing • Backward inclined aluminum wheel • Curb cap with prspunched
moundnp halals • Mote and drives isolated m shock mounts • Drain trough • Bale
bearing motora • Adjustable motor pulley • Adjustable motor plais • Fan shaft mounted
in bale bearing pillow blocks • Bearings meet or stood temperature rating of fan •
Static resistant belts • Corrosion resistant fasteners
SELECTED OPTIONS i ACCESSORIES
Switch • Nerna -1, TOggIs Mounted & Wired
Heat Baffle
UUcUL 762 - 'Power Vint. for Rest. Eth. Appliances"
r ■� Fea
...--
im..ruamerwri:= -___. 4 MIMI= V
1112==r1W I N I III I
MINIM P�.rill.�I �.
::gg
-
1111
rr i n - ,..... •--
Ift vs
gm Mk
UN
LwA • A weighted sound power Wed. baud on ANSI
• 81.4. dNA • A weighted sound pressure lead. Weed
oe 11.5 dB ifenuslon per cone bend at 5.05. Bones
calculated using AMCA 501 et 5,01t. •
5.10
em
rP.r x.a+Kwvna r �r.
Qty
Volume.
Model (CFM)
SP (k►. WC)
FRPM
p ower (hp.)
MOtor Information
Size (hp.)
V /C/P
Enclosure
RPM
1000
RSFP -120.7 2,734
0.25
596
0.0
3/4
115/50/1
TRFC
1725
Inlet Sound Power •
Octave Band
Appro. Fan
Weight (Its.)
Ws
OA
Sores
62.5 '
125
250
SOO
1000
2000
4000
8000
73
66
67
71
6060
69
ss
61
75
64
12 7
Damper Size
(M.)
Roof Opening
(art.)
Appro. Fan
Weight (Its.)
taxi.
21x21
160
Fan and Ventilator
24
31 I I
NOTES, An dimensions shown are in units of inches
Fan weight is without accessories
i
an.
ail
..M
SAD
w
4.141
w
SON
e
Q,
'o.2s
s •F s
__ - MARK: RSFP
RS F P Filtered Louvered Roof Supply Fan
CONSTRUCTION FEATURES
• Enlenor bass panels, louver sections and insulated cover all of aluminum construction
• Curb cap with prepunehed mounting holes • Mow and motor assembly hoisted on
shock mounts • Forward otaved steal fin wheel • Adjustable moor pulley • Adjustable
molar piste • Sall basting moor • Fan shaft mounted In ban bearing pillow blocks •
Static free belts • rasIsesnt listeners
SELECTED OPTIONS & ACCESSORIES
Standard •I in. Washable Aluminum Filters
UUcUL 706 • "Power VentlIeiors"
LwA • A welahlsd sound power levst, based an ANSI
51.4. AA • A weighted sound pressure Ravel, based
on 11.5 de attenuation per octave band el 5.011. Sons,
calculated wins *ACA 301 et 5.0 ft.
CVO
0.70
aw
as.
10 0
us
u,
Mu .�,sn..aw..•..r,aavwxrar,�'
-
-um
-
..
,
hair--
MEM
�w
, r ,'
maki.,�1
m
-mi
...
'
�um
um
- ..r
-a
-�-
.
-
,
-��
e`_--
.
amm
-
E11'if+NH
-psi-
-
wow
_
_
-���-
- -�� --�
Mil
-
---„-
-►..�-
-
-_
- -
M
WI
iWM ll
4
IV:
r
�
Fan and Ventilator
24
31 I I
NOTES, An dimensions shown are in units of inches
Fan weight is without accessories
i
an.
ail
..M
SAD
w
4.141
w
SON
e
Q,
'o.2s
s •F s
__ - MARK: RSFP
RS F P Filtered Louvered Roof Supply Fan
CONSTRUCTION FEATURES
• Enlenor bass panels, louver sections and insulated cover all of aluminum construction
• Curb cap with prepunehed mounting holes • Mow and motor assembly hoisted on
shock mounts • Forward otaved steal fin wheel • Adjustable moor pulley • Adjustable
molar piste • Sall basting moor • Fan shaft mounted In ban bearing pillow blocks •
Static free belts • rasIsesnt listeners
SELECTED OPTIONS & ACCESSORIES
Standard •I in. Washable Aluminum Filters
UUcUL 706 • "Power VentlIeiors"
LwA • A welahlsd sound power levst, based an ANSI
51.4. AA • A weighted sound pressure Ravel, based
on 11.5 de attenuation per octave band el 5.011. Sons,
calculated wins *ACA 301 et 5.0 ft.
CVO
0.70
aw
as.
10 0
us
u,
Mu .�,sn..aw..•..r,aavwxrar,�'
ACTIVITY NUMBER: MO2 -210
PROJECT NAME: THAI MALI CUISINE
SITE ADDRESS: 17310 SOUTHCENTER PARKWAY
X Original Plan Submittal
Response to Correction Letter #
DATE: 10 -29 -02
Response to Incomplete Letter #
Revision # After Permit Is Issued
DEPARTMENTS:
Ob
Build' ngu'vision
Public Works
Documents/routing sl ip.doc
2.28.02
PERMIT COORD COP`(
PLAN REVIEW /ROUTING SLIP
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Er
Incomplete
REVIEWER'S INITIALS:
PERMIT COORD COP(
F
5 I
Fire Prevention Q Planning Division
/DWG tt_y4i
Structural ❑ Permit Coordinator
DUE DATE: 10-31 -02
Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS RING:
Please Route S tructural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 11-28-02
PP Approved roved ❑ A roved with Conditions [� Not Approved (attach comments) C]
Notation:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
REGISTERED.-AS4PROVIDED BY
CONST CONT GENERAL LAW AS
REGIST. r °# EXP. DATE••
CCO1 MUTUAII041D5'02
EFFECTIVE DATE /25/
1 :'lbAt)`t`r I ? :i.��. 0 3/25/11996 996
MUTUAL INDUSTRIES INC
9832 17TH AVE 'S
SEATTLE' WA', ;981
Signature _
Issued by DEPA TMENT
LABOR -AND INDUSTRIES
0
E0l1PM1 I• SUIIEI)IiLE
'No Name / Size
1 Waiting bench
2. Dining Table (1-30" x42")
3. Dining fable (10 -26 "x30")
4. Booth (11-44" x6' )
5. Stool
O. ( punter (30 "x8' -6 ")
7. 1'\ alter station (3O "dx 1(1' -6 "I,)
8. (ashier Counter (30 "x4' -6 ")
9. ( ash Register
10. 2 I)r refrige'ator (47 "1,x30"dx
11. Sandwich Cooler (4'wx30'(1x 3'h)
12. Hood (45 "dxl6'I,)
13. Wok I nit (4I "(1x94 "I,x3'h)
14. Soup Stock Pot (18"w ‘25"(1‘24"h)
I. Range (2'x2')
I(. Broiler (2'x2x ")
17. De.•p fryer (16 "x28')
18. Work Kahle 2'x. ')
19. Vegetable Sink (38 "1,x28 "(1x3'h)
20. Shelving
14
21. 2 Dr Freezer (54 "wx30 "(tx78 "h)
22. Soiled / Pre -rinse I'nit (6 "d)
23. Dish Wash Machine (30"x311 ")
24. Clean Table (3' IA 30"(I)
25. R1op sink (2'x2')
26. Hot Water lank( Inn (;)
27. Transformer
28. Electrical panel
29. Walk in Cooler (S wx6'dx91 "h)
30. I)umpster
31. Ice Maker (350 #)
32. Coke Machine (2'x26 "xS')
33. Hand sink (13"(1‘17"w)
34. Hand sink (I8 "w x l S "I))
.35. Employee Cabinet
36. Dish cabinet (I11'x15 ")
\40K Ulf *i ;o )
4cPi ik,ILl^��
o n 4'
(V l i
. 10 WOO
. skp'�'Q hk 140
L ci >
V
ZAkqi
Al ;
4_fcf k Btr DMZ
,„
70 fWg. •
0
au'
(.4,4Q 4<l?.) I 17
4(4. 4k 1)V P11/
o A. )Vj
Wh �ry
xCtf.,)Y tyVi, zgZa._
lo?
x-
_IxPitt 6A. a;Wi 1 t
r
•
G'
■k.14zwKAfix vt")<
- ,._._��At� s -%PSG: /• f �
ft - -
.she �t gnu._.
P 11P'
'c
-7-700
I I
C,.,OPY
t
mat : _•ptvaIS are
suoj. ct to errors 2" or and :w provai of
plans does rot e .u:atitNn of any
ad: ted code or C;d11Z cf con -
tra4.tQr's espy of appro ?',. s. aclmo'.v'edged.
By
Date
Permit No
.140 CHANCES S BE • 4c,
THE SCOPE OF WITHOUT PF!OR
Ai¢PROVAL OF TUKWILA BUILDING DIV:FiZ)N.
NOTE REVS 'OHS w?u F+_O+JtQ A NEW PLAN SUOurrAj.
L�
, 9 /'t kf6N c6'< e 15 -7/
3/4. 61W CV/r, R f' -120 -7
a*1, ot f4 L/
SEPARATE �RPAIT
RQUiRED FOR:
(- :CHAW'.ItCAL
it - E. R: t
1?, S
Cle PIP'.vG
C:rf OF TIJKWILA
I';.; LONG G:v1S'ON
NOTES .
1. TILE EXHAUST & MAKE UP AIR SYSTEM SHALL BE
CONNECTED BY AN ELECTRICAL INTERLOCKING SYSTEM.
2. ALL EQUIPMENTS SHOWN ON THIS DRAWING SHALL BE AS
SPECIFIED OR EQUAL.
3. THE PROPOSED WALL TO BE CONSTRUCTED TO MEET TI
FIRE CODES FOR TYPE I HOOD IN LEYY'OF MINERAL WOOL
PAD( I HR FIRE RESISTIVE SI-IIELD).
STAINLESS STE: L SHEETS SHALL BE COVERED THE
ENTIRE COOKING AREA AND 18" EXTENDED TO NON -
COMBUSTION WAL:_ AREA.
. ALL HOOD AND DUCT JOINS & SEAMS SHALL BE
EXTERNAL GREASE TRAIT WELDED.
6. EXHAUS C FAN AND MAKi: UP FAN SHALL BE 24 "(MIN)
DISILARGE ABOVE ROOF.
7. MNINliM DISTANCE BETWEEN EXHAUST FAN & MAKE LT
FAN SHALL BE NOT LESS THAN 10'.
8. HOOD FIRE SUPPRESSION SYSTEM BY OTHER PERMIT.
The Scope of this Project
1. *('his is a TI project. To change from a vacant retail space to a seat
down Thai cuisine restaurant. The existing structures, floor, ceiling,
& walls shall be remained unchanged.
2. The works to he finished as in the following:
1. Floor plan 2. Electrical plan 3. Plumbing plan 4. Hood plan
a. New ( ;WB wall and floor covering
b. Installation all the equipment in the kitchen and the dining area.
c. Plumbing for the kitchen area.
(I. Installation a commercial kitchen Ilood for cooking equipment.
e. Electrical system.
PI)JI':(' I INFORM I ION
1Na
) �
()Matte:
ocation:
•
Thai Mali Cuisine Restaurant ')"
20(H) SU J
17310 South center pkwy, Tukwila W 1 9818
Tenant : ()uchro Saelee/ 425- 271 -145
Designer : Thomas 1,1 253- 973 -8500 Ro iZ
161122 12 Ave., SW 13urien 1'x',1' -2808
Parcell # : 26231)4 9079 - 06 uiJ 2 9 2002
Zone : ( 'on u :rereial PERMITcaNTEF-
Seismic lone : 3
( (instruction Type : (\1I
ffl4 i7t �fi;7
14243 SE 157 Place, Renton, W 1 ')')()SS `�, 7, .-- c+` 4
Property Owner : Milk Northwest (Dave Moore) /503-63(1 -- i
4949 SW Meadow s Road, #675, I,ake Oswego OR 9703 --"'
('ontractor: To he decided later
PIOZO/o