Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M02-220 - SHERWIN WILLIAMS
M02 -220 Sherwin Williams 16650 W Valley Hy Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: Signature: Print Name: doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 2523049085 16650 WEST VALLEY HY TUKW SHERWIN - WILLIAMS 16650 WEST VALLEY HY, TUKWILA, WA TAB TWO LLC 7419 34TH AVE NW, SEATTLE WA PETER CRELLEY P.O. BOX 33370, SEATTLE, WA PRO -STAFF MECHANICAL INC PO BOX 33370, SEATTLE, WA Contractor License No: PROSTMI006C8 Permit Center Authorized Signature: DESCRIPTION OF WORK: REPLACE ONE EXISTING 4 -TON AC UNIT WITH ONE NEW 4 -TON AC UNIT. La.e;z_ MECHANICAL PERMIT MO2 -220 �GC�L Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 361 -0071 Phone: 206 - 361 -0071 Expiration Date: 02/28/2004 MO2 -220 12/12/2002 06/10/2003 Value of Construction: $4,925.00 Fees Collected: $46.50 Type of Fire Protection: N/A Uniform Mechnical Code Edition: 1997 Date: /°z �Z I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating struction or the perfor�• • - of work. I am authorized to sign and obtain this mechanical permit. Date: (2 — O Z This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 12 -12 -2002 ACTIVITY NUMBER: MO2 -220 DATE: 11 -18 -02 PROJECT NAME: SHERWIN - WILLIAMS SITE ADDRESS: 16650 WEST VALLEY HY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Bu i Public o In Division (� j2-l0 rks DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: 1:9/ Documents/touting slip.doc 2 -2B -02 APPROVALS OR CORRECTIONS: P'S PERMIT C00R CQpy PLAN REVIEW /R SLIP REVIEWER'S INITIALS: 5/2. / /4' Fire Prevention Planning Division Structural ❑ Permit Coordinator Incomplete I ERMIT COORD DUE DATE: 11-19-02 DUE DATE: 12 -17 -02 Dc Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER'MAILED: 11" I0'02' LETTER OF COMPLETENESS MAILED: 'Departments determined incomplete: Bldg ce Fire ❑ Ping ❑ PW ❑ Staff initials: JCel/;—' TUES /THURS ROUTING: Please Route [Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: Approved ❑ Approved with Conditions [f Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ..,......w....... ... .+.,t„,...,,.,w.«ww�wm�re.we+r. ++ v. rwawr+ weanwearsw .+vaarsRa R Y , Xf0 12ts�2flN�114 November 19, 2002 Peter Crelley PO Box 33370 Seattle, WA 98133 RE: Letter of Incomplete Application #1 Development Permit Application Number MO2 -220 Sherwin Williams 16650 West Valley Hy Dear Mr. Crelley: This letter is to inform you that your permit application received at the City of Tukwila Permit Center on November 18, 2002, is determined to be incomplete. Before your permit application can begin the plan review process the following items need to be addressed. Building Department Ken Nelsen, Sr. Plans Examiner 206/431 -3677 1. Applicant must provide structural evidence that the existing roof can support new 500 lb roof HVAC regardless of existing HVAC. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3684. Sincerely, Kathryn A. Stetson Permit Technician encl City of Tukwila Department of Community Development Steve Lancaster, Director File: Permit File No. (MO2 -220) Steven M. Mullet, Mayor '300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 - 3665 DEPARTMENTS: Building Division Public Works Approved Notation: Documents/routing slip.doc 2.2802 REVIEWER'S INITIALS: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MO2 -220 DATE: 11 -18 -02 PROJECT NAME: SHERWIN- WILLIAMS SITE ADDRESS: 16650 WEST VALLEY HY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued Fire Prevention DETERMINATION OF O PLETENESS: (Tues., Thurs.) Complete 10 D Comments: `ttwf Yr•-‘ Approved with Conditions 0 Structural ❑ Incomplete a ( lrL TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required Planning Division Permit Coordinator DUE DATE: 11-19-02 Not Applicable ❑ ev1ciQ.vcre eKts4T -I V Ac. revAr e / o.0 ext4 !dr 01 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DATE: LI, 17 DUE DATE: 12-17 -02 Not Approved (attach comments) ❑ DATE: C e:7Z Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT NO.: I V W z" Z ti MECHANICAL PERMIT APPLICATIONS INSPECTIONS 0 6 2 Pre- construction 50 WSEC Residential 60 WA Ventilation/Indoor AQC 610 Chimney Installation/All Types 700 Framing 080 Woodstove 090 Smoke Detector Shut Off 100 Rough -in Mechanical 101 Mechanical Equipment/Controls 102 Mechanical Pip/Duct Instil 105 Underground Mech Rough -in 115 Motor Inspection 400 Fire - Final 800 Mechanical - Final 4015 Special -Smoke Control System CONDITIONS 10001 No changes to plans unless approved by Bldg Div a 10002 Plumbing permits shall be obtained through King Co 10003 Electrical permits obtained through L & I 10005 AU permits, insp records & approved plans available 10014 Readily accessible access to roof mounted equipment 10016 Exposed insulation backing material 10019 All construction to be done in conformance w /approved plans fc 10027 Validity of Permit 10036 Manufacturers installation instructions required on site 0 10041 Ventilation is required for all new rooms & scams 0 10042 Fuel burning appliances ❑ 10043 Appliances, which generate.... ❑ 10044 Water heater shall be :mchored.... Additional Conditions: TENANT NAME: FEES Basic Fee (Y/N) Supplemental Fee (YIN) Plan Check Fee (Y/N) Furnace/Bumer to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor - mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (q ty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfin (qty) over 10,000 cfin (qty) Evaporative Cooler (qty) Ventilation Fan (city) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm/Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter SS) Add'I Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'l Plan Review (hrs) Plan Reviewer: Permit Tech: Date: 1-11 Date: ACTIVITY NUMBER: MO2 -220 DATE: 11 -18 -02 PROJECT NAME: SHERWIN- WILLIAMS SITE ADDRESS: 16650 WEST VALLEY HY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division ❑ Fire Prevention Public Works ❑ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ TUES /THURS ROUTING: Please Route ❑ Structural Review Re REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 PLAN REVIEW /ROUTING SLIP Incomplete ),C REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 11-19 -02 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER • MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required DATE: / / / /V0 7s DUE DATE: 12 -17-02 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Project Name /Tenant: . � � S Nr= aZwJN - WJt_L0 M s Value o M h 'uip ©: Site Addres . 1 . . • 0 144 T City Stat Zip: u.�_ % — vi< i.,r - 1 � � Tax Parcel Num er: z Z3 0 Property O r: TwD L L..0 Phone: ( 7 4_ 6.2T7 Stre t Address: G - W _ r City Sta Fax #: ( zoo Z1 — ' z Contractor: -� � Phone: (2,0 to ) 4,1_ 0 0 j Street Address: P u- a 0 , 333 0 J City State/Zip: .5 -A- rr a , L t/A , Fax #: (2 6 ) 3la/ _• ay i- i 7 Conikct Person: V - -n '2. C ie -Ua: y City /State/Zi : , f4 Wi - ° 1,13 - 3 Phone: (2, t , ) 34/_ 007) Street Address: P 0. X � 3717 City State /Zip: SF A i rZE , L✓A- %/3-3 Fax #: (•), L ) 3 �' J — 0414 d UµL)' lNG !:ONNERfOR4ORIZEDeA'GENTaio .., i:. ' '.:'. :-:/ .. Date: �/ f� 2 tint name: "'�"� �� 0 i Phone: (��) 3G. / -71 Fax #: ( L. -56 01/24- t� Address . t' u_ 13v,� 3 7c7 City /State/Zi : , f4 Wi - ° 1,13 - 3 Mechanical Permit Application 11/2/99 n,ecli pern,ll.doc CITY OF TC ..WILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. ;,�,Y i,�a- t�c:,a� . q'���� }Y FX`,1i �• .• i' :a• �tii y .. .., ... .'.. - :. .. �. .. . �;:�; ,..:';;!�v " GHANICAL PEltf VIII,REVIEVIJ AND REQl1ESTED: (TO `BE'FILLED OUT'BYAPPL'ICAN Description of work to be done (please be specific): fZEPC./A -c:.-F' ON:: F_X/Si1NG - Tom L t,/N t-r 14/ITI4 ONJ 1`►t= let/ 4 -TON AG - L.Ir:_ C1474-NC,T = -OLT Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: / /— / Date application expires: Application taken by: (initials) SAS' NY4,57T.t, ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H..V A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be rooted to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. New Single Family Residence Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements Heat loss calculations or Form H -6. Equipment specifications. 11/2/99 ndscp Change -out or replacement of existing mechanical equipment Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water . heaters or vents being installed or replaced. 1 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2523049085 Address: 16650 WEST VALLEY HY TUKW Suite No: Tenant: SHERWIN - WILLIAMS Signatur Print ame: doc: Conditions PERMIT CONDITIONS MO2 -220 Permit Number: MO2 -220 Status: ISSUED Applied Date: 11/18/2002 Issue Date: 12/12/2002 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Readily accessible access to roof mounted equipment is required. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of w Date: (/ 2 ^12 '-C., Printed: 12 -12 -2002 doc: Receipt Payee: PRO -STAFF TRANSACTION LIST: ACCOUNT ITEM LIST: City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2523049085 Permit Number: MO2 -220 Address: 16650 WEST VALLEY HY FUKW Status: APPROVED Suite No: Applied Date: 11/18/2002 Applicant: SHERWIN - WILLIAMS Issue Date: Receipt No.: R020001733 Payment Amount: 46.50 Initials: SKS Payment Date: 12/12/2002 09:27 AM User ID: 1165 Balance: $0.00 Payment Check 7203 46.50 Current Pmts Amount MECHANICAL - NONRES PLAN CHECK - NONRES Type RECEIPT Method Description Description Account Code 000/322.100 37.20 000/345.830 9.30 Total: 46.50 3339 12/12 9710 TOTAL 46.50 Printed: 12 -12 -2002 Pro t: Type spection: Ad ress: ( 6 d to .1/A{Z6 - '/M Date Called: � -0/ ' pecial Instructions: 0-4‘...c ���O /Z 7Z ms/o, Date Wanted: Fn. /-,2 -0.`z, Requester: Pho a No: 7� :� ; 3 7 36.1 ...,. J�'; � �:,',,' w,; �5;.• a' r'_ �t'. Y�s�f;;. t' ito ";r.;id �5i:;4;�::1,auvis.i:;s INSPECTION REC MD Retain a copy with permit INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)4 -3670 Approved per applicable codes. COMMENTS: Ok— F■Kct I -N/ Inspecto El Corrections`requirire p idr to approval. Date: - 2 _ 03 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: { CV( APPRO�ED ,IA DEC 1 N" Pa hYJ t cU c g' FILE COPY I Packaged Gas /Electric Rooftop Units c _ i p si-far&t.AN - 1 � 6 Sv w. VA u.�� I4/U1tw Tv /; I-A PrecedentTM 3- 10Tons -60Hz October 2001 ECEIVED CITY OF TUKWILA Nov 1 8 z002 PERMIT CT- NT Lip R1:PR0006 -EN MD Z -ZZ0 � Table GD-1 - General Data Cooling Performance' Gross Cooling Capacity SEER° Nominal CFM / ARI Rated CFM ARI Net Cooling Capacity System Power (KW) Heating Perfonnance' Heating Models Heating Input (Btu) Heating Output (Btu) AFUE %° Steady State Efficiency ( %) No. Bumers No, Stages Gas Connection Pipe Size (in.) Compressor No/Type Outdoor Sound Rating (dB)° Outdoor Coil - Type Tube Size (in.) OD Face Area (sq ft) Rows/FPI Indoor Coll -Type La ced Tube Size (in.) 0. 125 Face Area (sq ft) .67 Rows/FPI 16 Refrigerant Control Sh rt Orifice Drain Connection No/Size (In.) 1 4 NPT Outdoor Fan -Type opeller No. Used/Diameter (in.) 1/22 DriveType/No. Speeds 'irect/1 CFM 2,550 No. Motors/HP 1/0.20 Motor RPM ,075 Direct Drive indoor Fan - Type FC = ntrifugal No. Used/Diameter (in.) 1/11 10 DriveType/No. Speeds Dir: 1/2 No. Motors 1 Motor HP (Standard/Oversized) 0.33/ 50 Motor RPM ( Standard/0versized) 950/1, ° 0 Motor Frame Size (Standard/Oversized) 48/ Belt Drive Indoor Fan - Type No. Used/Diameter (in.) DriveType/No. Speeds No. Motors Motor HP (Standard/Oversized) Motor RPM ( Standard/Oversized) Motor Frame Size (Standard/Oversized) Refrigerant Charge (Lbs of R - 22)' . 1 /Climatuff® He tic (3 - 4Tons) General Data Standard Efficiency 3-Ton Convertible Units W 4 -Ton Convertible Units Y CO36A1 YSCO .A3, A4, AW YSC048A1 YSC048 3Z400 10.5 ,200/1,200 36,000 3.91 Low edium High Low M 60,000 : 0,000 120,000 60,000 80, 47,000 . ,000 95,000 48,000 64, 80 :0 80 81 81 80 :° 80 81 81 2 2 3 2 2 1 1 1 1 1 1/2 1/2 1/2 1/2 1/2 84 Lan • 0.31 5 7. 2/7 3. 37,400 50,300 10.7 10.0 1 •00/1,200 1,600/1,600 6,000 48,000 3.79 5,28 um High 00 120,000 0 96,000 81 81 3 1 1/2 1 /Climat Hermetic L. cad 3125 7.19 2/17 nced Lanced anced 0.3125 0.3125 .3125 5.67 6.68 6.17 2/16 3/16 16 hort Orifice Short Orifice Sho Orifice 1/ NPT 1/ NPT 1/ NPT Propeller 1/22 Direct/1 2,550 1/0.20 ,075 FC C' trifugal 1/10 10 Dire • 2 1 0.33/0. 930/1,10 48/48 FC Centrif , al 1/11 x 1 BelWariable ' heave 1 1.00/ 1,750/ 56/ Filters -Type Thro away Throw. ay Throwaway Thro way Furnished? s Ye Yes Y s (No,) Size Recommended (2) 20 25 x1° (2) 20 x ' 5 x 1° (2) 20 x 25 x 1° (2) 20 x 5 x 1° 3 Low Medium High Low Me ium High 60,000 80,000 0,000 60,000 80, r r 0 120,000 47,000 63,000 ,000 48,000 64,0 r r 96,000 80 80 80 81 81 81 80 BO 80 81 81 81 2 2 3 2 2 3 1 1 1 1 1 1 All dimensions are in inches /millimeters. 3, 4, and 5 Ton Standard Efficiency — Low and Medium Heat 3 and 4 Ton High Efficiency — Low and Medium Heat 3, 4, and 5 To Standard Efficiency —High Heat 3 and 4Ton High • - : ncy — High Heat 5Ton — High Efficiency , Medium, and High Heat RTPRC006-EN EVAPORATOR SECTION ACCESS PANEL ALTERNATE CONDENSATE DRAIN CONNECTION 3/4. 14 NPT DIA. HOLE SECTION PANEL ALTERNATE CONDENSATE DRAIN CONNECTION 3/4.14 NPT DIA. HOLE Dimensional Data 4 1/4' 108 MM 89 7/8 1749 MM 1/2 NPT GAS CONNECTION 4 1/4' 108 MM 1/2 NPT GAS CONNECTION CONTROL AND COMPRESSOR ACCESS PANEL CONTROL AND COMPRESSOR ACCESS PANEL 5 5/8' 143 MM 244 MM 95/8' 244 MM 5 518' 143 MM (3 - 5Tons) TOP PANEL 4 1/4' 108MM• 5 9/16' 141 MM 7 5/8' 194 MM 44 1/4' 1124 MM TOP PANEL 4 114 108MM• 59/16' 141 MM 7 5/9' 194 MM 44 1/4' 1124 MM CONDENSER FAN 32 /4' 819 MM CONDENSER FAN CONDENSER COIL UNIT CONTROL WIRE 7/8' (22MM) DIA. HOLE SERVICE GAUGE PORT ACCESS 1 3/8' (35MM) DIA. HOLE UNIT POWER WIRE 1 3/32' (28MM) DIA HOLE 38 /4' 921 MM CONDENSER COIL UNIT CONTROL WIRE /8' (221.1M) DIA. HOLE GAUGE PORT ACCESS 35MM) DIA. HOLE UNIT POWER WIR 1 3/32' (28MM) DIA. HOLE 71 z F cx O 0 ND co W W D LL Q 22 a F O Z W • 0 0— ▪ 1— W T J W u. r 2 O . W Z o z • TRAM° All dimensions are in inches. 4 . p14 H 3518 MM - "`235 MM 3 -5Tons — DownilowAirflow Supply and Return; Through the Base Utilities 3 -5Tons — Horizontal Airflow Supply and Return 3 -5Tons — Unit Clearance and Roof Opening Dimensional Data 24' 610MM 4 3116' 106 3 1 r; 91 90 • RETURN TBU CONDEN 0 23112' 597 MM CLEARANCE 37' (940 MM) CLEARANCE 48' (1218 MM) (� 5Tons) ATE ( 4 9118' 118MM THROUGH THE BASE GAS 3/4.14 NPT CONDENSATE DRAIN 27 9158' 701 MM \L ROOF OPENING 124 4 7/5' - THROUGH 51115' THE BASE 12519 ELECTRICAL 253 MM 17 1/4' 8 7/8 438MM 225MM CLEARANCE iipik HORIZONTAL FLOW - 18' (457 MM) DOWNFLOW 38' (814 MM) 6 311118' 165 94 MM 3 3/18' BIMM 37' �\ 1940 MM) 4412' \ / 11130 /AM) (914 38' (914 MM) 4 3/4' 121MM Unit Tons Model No "" YHCO36A • YSCO48A YHC048A YSC060A YHC060A ,.. YSC072A3•H <. YHC072A3•H`s YSC090A3•H 3 4 5 6 8 10 W._ S1(..# ,l', `^ 7 !.�a'1Wleximurti;Wel9hts'ILtis)'; ` Comer Weights (Lbs)1 `)Sfiipping =;i ?s?`Net iir +.;r4' "art ; ` °'A B C • 4 ^.i1 -', try ; 534 {`r ° - 4801.- 151 t ;158 ::WiG:i 559ap =.. ...z r 505 ti! . , 159 � 166 4576';1 ;1:522 *, 169 ...::628r:f '):�i::' ::574 :M!i -, I,. .179 249 r 249 7 YSC092A3•H' YHC092A3'H'r % 92311:.. YSC102A3`H' . _' tl'r'`, :r.t : ;986 • ` "; ... 899 YHC102A3!H'... ;'i; w 'ia? .1 -957 .. YSC120A3•H` "::;ei + rri': rii. 1;`.1074,' :.. 987 YHC120A3 "H 1147 1060 NOTE: .1 1. Comer weights are given for Infortnation only. 2. Weights are approximate. • CENTER OF GRAVITY WIDTH D • • : ,273 277 306 297 310 325 342 CENTER OF GRAVITY �- LENGTH - -► CENTER OF GRAVITY Table W2 — Factory- installed Options Net Weights Oslo Accessory Economizer Barometric Relief Powered Exhaust Motorized Outside Air Damper Manual Outside Air Damper Roof Curb Oversized Motor Belt Drive Motor Smoke Detector, Return Smoke Detector, Supply Coil Guards Hinged Doors Powered Convenience Outlet Through the Base Electrical Through the Base Gas Unit Mounted Circuit Breaker Unit Mounted Disconnect Nover Control D Length Width 124 96 109 32 19 128 101 110 32 19 130 108 109 33 19 133 114 126 32 20 134 105 114 32 18 140 119 136 32 20 193 132 161 39 21 198 141 184 39 22 208 146 193 38 22 222 147 175 40 21 243 165 210 39 22 243 165 194 40 21 252 175 220 40 22 265 183 213 40 21 277 197 245 40 22 3 -5Tons 26 7 20 16 70 5 31 7 5 12 10 38 8 5 5 5 8 NOTES: 1.WeIghts for options not listed are >5 lbs. 2.Net weight should be added to unit weight when ordering factory- installed accessories. TRANE Center of Gravity (In.) Net Weight 6- 10Tons 36 10 80 30 26 115 8 7 5 20 12 38 13 5 5 5 8 RTPRC0061 '�;`.tr "'•Y t` "•'( 1; rli ..:..l; , ,: 79 rft m1 0 co 0 CO la 9 • Li. LL ? . H W o Z F^ jjj U ON 0H W 1— I V- 0 . w U O Z i Unit Tons Model No. 3 Y#CO36A3 Y#CO36A4 Y#CO36AW 4 Y#C048A3 Y #C048A4 Y #C048AW 5 Y #C060A3 Y#C080A4 Y#C060AW Y #S072A3 6 Y #S072A4 Y #S072AW YSC090A3 YSC090A4 7 , /z YSC090AW Y#C092A3 Y #C092A4 Y#CO92AW Y#C102A3 81/2 Y #C102A4 Y #C102AW Y#C120A3 10 Y #1:19nA4 Y #C120AW #Indicates both standard end high efficiency airflow. 66 Motor NOTES: 1. HACR breaker per NEC. Table ED-3 - Unit wring - Standard Efficiency Electrical Data Standard Indoor Fan Motor Table ED -2 - Electrical Characteristics - Evaporator Fan Motors - Belt Drive Standard Evaporator Fan Motor Oversize Indoor Fan Motor Optional Belt Drive Indoor Fan Unit Minimum Maximum Fuse Minimum Maximum Fuse Minimum Maximum Fuse Unit Operating Circuit Size Or Maximum Circuit Size Or Maximum Circuit Size or Maximum Tons Model No. Voltage Range Amity Circuit Breaker' Ampacity Circuit Breaker' Ampacity Circuit Breaker' YSCO36A1 187 -253 25.3 27.7 40 - 3 YSCO36A3 187 -253 20.3 30 20.6 30 YSCO36A4 414-506 9.2 15 10.4 15 10.6 15 YSCO36AW 517-633 7.7 15 8.3 15 8.3 15 YSC048A1 187 - 253 34.0 50 36.1 50 - - YSC048A3 187 -253 23.9 35 26.0 40 25.3 35 4 YSC048A4 414 -506 12.8 20 14.4 20 13.6 20 YSC048AW 517 -633 9.8 15 10.6 15 10.0 15 YSC060A1 187 -253 47.3 60 49.0 60 - - YSC060A3 187 -253 31.5 50 33.6 50 30.3 45 5 YSC060A4 414 -506 16.0 25 16.3 25 15.6 25 YSC060AW 517 -633 12.2 15 12.8 20 11.8 15 YSC072A3 187 -253 32.2 50 33.5 50 - - 6 YSC072A4 414 -506 17.6 25 18.2 25 - YSC072AW 517 -633 12.8 20 13.6 20 - YSC090A3 187 -253 42.7 60 45.8 60 - YSC090A4 414 -506 22.6 35 24.1 35 - Th YSC090AW 517 -633 17.6 25 18.8 25 YSC092A3 187 -253 38.9 50 42.0 50 YSC092A4 414 -506 20.5 25 22.0 25 YSC092AW 517-633 15.5 20 16.7 20 YSC102A3 187-253 44.4 60 47.5 60 81/2 YSC102A4 414 -506 24.0 30 25.5 35 - YSC102AW 517 -633 19.5 25 20.7 25 - YSC120A3 187-253 50.9 60 54.9 60 - 10 YSC120A4 414 -506 26.9 35 28,9 35 - YSC120AW 517-633 21.8 25 23.5 30 - Amps Amps No. Volts Phase HP FLA LRA No. Volts Phase HP FLA LRA 1 208-230 3 1.0 5.0 32.2 - - - - - - 1 460 3 1.0 2.5 16.1 - 1 575 3 1.0 1.7 13.2 - 1 208-230 3 1.0 5.0 32.2 - 1 460 3 1.0 2.5 16.1 - 1 575 3 1.0 1.7 16.1 - 1 208 -230 3 1.0 5.0 32.2 - 1 460 3 1.0 2.5 16.1 - 1 575 3 1.0 1.7 16.1 - - - - - - 1 208-230 3 1.00 5.00 32.20 1 208 -230 3 2.00 6.30 48.00 1 460 3 1.00 2.50 16.10 1 460 3 2.00 3.10 24.00 1 575 3 1.00 1.70 13.20 1 575 3 2.00 2,50 18.20 1 208 -230 3 2.00 6.30 48.00 1 208 -230 3 3.00 9.40 83.00 1 460 3 2.00 3.10 24.00 1 460 3 3.00 4.60 42.00 1 575 3 2.00 2.50 18.20 1 575 3 3.00 3.70 31.00 1 208 -230 3 2.00 6.30 48.00 1 208 -230 3 3.00 9,40 83.00 1 460 3 2.00 3.10 24.00 1 460 3 3.00 4.60 42.00 1 575 3 2.00 2.50 18.20 1 575 3 3.00 3.70 31.00 1 208 -230 3 2.00 6.30 48.00 1 208 -230 3 3.00 9,40 83.00 1 460 3 2.00 3.10 24.00 1 460 3 3.00 4.60 42.00 1 575 3 2.00 2,50 18.20 1 575 3 3.00 3.70 31.00 1 208 -230 3 3.00 9.40 83.00 1 208 -230 3 5.00 13.40 112.00 1 400 3 3.00 4.bU 42.00 1 460 3 5.00 6,60 56.00 1 575 3 3.00 3.70 31.00 1 575 3 5.00 5,40 41.00 Oversized Evaporator Fan Motor RT PRC006 -EN File: M 02 -0220 35mm Drawing #1 Copies _ Description of items: Existing equipment cutsheets DEC -05 -2002 10:45 To: PRO -STAFF MECHANICAL INC. Message: Ken Nelson City of Tukwila STAW3". "'""" ""-- b]FOR SIGNATURE; TB.EL'iads: (205) 3i1.0071 FAX (MN) 351-0424 PLEASE VISIT OUR WEB SITE AT 1MNW.pro- mechwtiCal.com PRO -STAFF MECHANICAL Department of Community Development DOCUMENT TRANSMITTAL Dot: 12/05/02 From: Polar Crelley peterrpro- staffinechanical.com prof MO2-220 SENT VIA: ® FAX: (208) 431 -3Q 12) Total Pages; ❑MAIL; OHAND DELIVER; ['OTHER: OFOR APPROVAL; ❑FOR YOUR RECORDS; 206 361 0424 I 902 No th 127 ST. Correspo nee to: PO Banc 3$70 Seattle, V1.. 98133 Please call with any questions. „ot *3 ) 1.• 0 44ke Sincerely, Peter Crelley Sales Engineer COMMERCIAL HVAC CONTRACTORS SYSTEM DESIGN & INSTALLATION SHEET METAL FABRICATION 24 HOUR EMERGENCY SERVICE PREVENTIVE MAINTENN4CE ;medmh - nzu -x SOO • DEC -05 -2002 1:45 PRO -STAFF MECHANICAL DESCRIPTION • YORK Sunline 11 Year-Round Air Conditioners are custom' . designed and completely factory 'assembled units offering a . total . comfort system with cooling: and g -fired .heating. • • The units ,provide excellent 'application flexibility with. four basic' sizes furnishing cooling capacities from 36 to ' 60 Mph and heating.capacities from 80 to :160 Mbh input. Units may be • installed on . the .rooftop or.•at.ground level. Sunline 11 units are shipped in one and installation consists of simple power wiring; gas piping, and connecting • of ducting — providing' a. *id - and 'eoonomical field: in- '. • .stallation. A single unit with the•full ; line .of field installed accessories is ideal, for commercial 'applications such : as a small. business. In large buildings,.zoned is,available' through multipte•installations. • • • FEATURES . • GUiET OPERATION — Sunline 11 units are solidly con- • structsd and engineered with noise- reduction as a prime consideration. YORK •utilizes . centriftigal blowers which circulate the •air quietly and gently; Panels are lined with thick fiber glass insulation and the• compressors, are mounted • 'On 'resilient isolators assuring quiet' operation. Operating. sounds are elso'supproused by the wood nailing strip on the optional roof - mounting .curb, • the. insulated .'plenum plat- .• form and the flexible supply .and retutri ducts. • • •FREE COOLING (With Optional Economizer) — Addingthe economizer to the return air.•side of the plenum accessory provides• a means to'. use. cool outside to supply the • ' building cooling requirement. :Reduced compressor' operat -. Ing time lowers the .overall operatina•costs.• • • COOLING MAZE COILS This carefully engineered 3/8 inch, staggered copper tube; corruguted aluminum fin coil is designed for maximum air.w.aurfaoe contact and conse- quently provides the optimum in heat transfer'performance, 206 361 0424 P.02/ FORM 630.011-$02 (671) STtJZL✓I SUNLI1NE LIGHT COMMERCIAL YEAR -ROUN AIR CONDITIONERS DURABLE CONSTRUCTION - The unit is rigidly con - sfucted.with• a sturdy base and the :frame is' covered with 20-gauge steel panels. The exterior is protected with Weather Sentry Caribbean Blue finish,'which'essures maxi- . mum protection and stay -new appearance for years.. • POSITIVE REFRIGERANT CONTROL — YORK incor- porates large -bore capillary tubes which meter refrigerant efficiently — with no moving parts. SIDE BYVSIDESUPPLY.AND RETURN AIR O.PENiNGS - This superior arrangement provides, a more .compact, eco- nomical and simplified installation' than: the complicated over -under. arrangements. • FAST CLEAN GAS HEAT = Sunline II units are available . for use with natural 'gas. (Propane conversion kits are avail- able for field assembly.) The YORK - designed, self - cleaning .burners assure maximum fuel efficiency: and:'low. cost heating. The aluminized steel heat exchanger is guaranteed for ten full years. These units incorporate a mechanical draft which. eliminates the need for a chimney. This °feature also provides'adequate combustion air at all times for clean, • smokeless flue product discharge. An air proving switch, in the combustion air. stream, keeps the gas.valve closed when 'the venter fans are not operating.' An intermittent pilot is ignited by a spark ignition system — conserving. fuel and operating cosu. Jet tube, aluminized •steel, lanced multi - port• burners provide even heat dispersal within, the heat exchanger, which prevents hot spots and burnouts: Burners are Installed on a removable burner rack. • BUILT -IN MOUNTING RAILS — This feature, provides added durability to this superior. constructed unit, These rails provide a ventilation area under the unit, thus elimi- nating moisture collecting areas and this provides maximum rust prevention. DEC -05 -2002 10:46 PRO —STAFF MECHANICAL COMPRESSOR GUARD PROTECTION — A decrease in refrigerant charge. eliminates the need for crankcase heaters on all units. Each compressor has built-in pressure relief valves. Temperature controls are available on all units to protect the compressors from abnormal operating conditions. ACCESS PANELS — Components that may require service are easily accessible through removable access panels. Also, the units have complete top panels that can be removed, making all components readily available for service. These features reduce expensive servicing hours. GAS -FIRED HEATING CAPACITY -- MOH Rated in accordance with A.G.A. for natural and propane gas for elevations up to 2,000 feet. For altitudes above 2,000 feet, reduce rating 4% for each 1,000 feet above sea (evil. SA3e0080 -E SA38G1o5 -E 106 79 SA36G120 -E 5A42G120 -E 120 90 SA48G120 -E SA81 G180 -E 180 120 80 so 125 1200 •Furnaces can be derated to 50% by: 1. Adjusting the gas pressure regulator. 2. Reducing size of orifices. 3. Adding two -step, hi -lo fire heating accessory. (Natural gas only.) 1400 1850 A CCESSORIES FOR FIELD INSTALLATION NATURAL TO PROPANE CONVERSION — A conversion kit containing the necessary components to modify a natural gas unit to propane gas. Complete step -by -step instructions are furnished with each kit. TWO-STEP, HI -LO FIRE HEATING — This accessory consists of a solenoid valve and all parts necessary to Install it on a unit. It provides for either full or reduced capacity operation of the unit, consequently furnishing maximum efficiency. (Natural gas only) 2 OTHER FEATURES INCLUDE — 206 361 0424 P.03/11 1. Multi -speed blower motor permits selection of speed to provide best air flow requirement. 2. Quick curb assembly — a special aircraft type fastener holds the fastening nuts In place for easy assembly. 3. Flexibility of Installation — the flexible supply and re- turn ducts eliminate the need for perfect alignment of unit and concentric diffuser. ARI STD. CAP. MOH ARI STD. UNIT EER ARI SOUND RATING LOW - VOLTAGE STARTING, SINGLE PHASE — This start assist kit consists of a solid state device that is mounted in parallel with the compressor run capacitor to assist starting when low voltage conditions exist. CONTROL PANEL PACKAGE — This is a decorative control panel and thermostat for regulating cooling and heating. Indicating lights, which show system performance are included in this package. LOWAMBIENT CONTROL (45 ° F to 20 ° F) — This control is available for models SA36, 42, 48 and 61 to allow cooling operation with ambient temperatures down to 20 ° F. The accessory includes all the necessary components and a step -by -step installation procedure. CONDENSER COIL PROTECTIVE GRILLE -- This is a wire grille mounted to the unit's exterior to protect the condenser coil from damage. THERMOSTATS — These are low - voltage, cooling /heating thermostats with either automatic or manual changeover. ROOF MOUNTING CURB — All curbs have load bearing tests available and ere approved by the National Roofing Contractors Association. Curbs are shipped knocked down for easier handling. LENUM AND UNIT PLATFORM — are designed and painted to match the Sunline ii unit and are sized to fit the roof - mounting curb accessory. The plenum is equipped with filter rack and filter access door. PIe um allows for either square or round duct connections. up SUPPLY AND RETURN DUCT KITS — Consists of two pieces of four foot long flexible insulated duct. Both ends of the ducts hive screw controlled metal clamps for easy installation. IP Copyright by korg•Werner Corporation 1976 — ALL RIGHTS RESERVED C DEC -05 -2002 10 47 PRO - rzTAFF MECHANICAL 8% TO 30% OUTDOOR AIR LOUVER - allows fixed eatakiL amounts of outdoor air to enter the air stream. The accessory is completely assembled and includes the remov- able opening covers, screened inlets and a cleanable filter. (Not shown) FORM 520.09.8G2 ACCESSORIES (Cont'd.) / ‘ 11 / 1F VIPAOttke›. CONCENTRIC DIFFUSER - designed to convert a side -by- F6++i1M side duct arrangement into a concentric distribution of air. The diffuser is flush mounted completely insulated, assembled, and internally baffled to provide four way supply air distribution with a center return. Adjustable supply louvers, hanging rings, anti -sweat gasket, and round duct flanges for use with flexible ducts make the assembly complete ready to fit into a 2' x 4' suspended ceiling grid, ECONOMIZER - is completely assembled and ready to mount in the return air side of the plenum accessory. The economizer is designed with a single blade damper which mixes the return aft with the outdoor air. It outdoor air conditions are favorable, the unit compressor is shut -off to provide free cooling using outside air. Inside air is exhausted by allowing a portion of the return air to escape thru pressure relief dampers. The economizer is available for the SA36G, SA42G, SA48G, and SA81G. COOLING CAPACITY - MBH 1300 1550 1750 2100 72 45 21 67 40 28 62 36 34 57 30 29 72 52 28 67 48 36 62 43 43 57 37 37 72 67 62 72 67 62 57 58 54 49 43 70 85 57 50 28 39 47 42 36 50 55 48 5.3 5.1 4.8 4.5 6.2 6.0 5.8 6,5 7.1 6.9 6.7 6.4 8.6 8.4 8.0 7.7 41 37 33 28 47 44 39 34 54 50 45 40 65 62 53 46 21 28 33 28 25 33 39 34 27 37 46 40 35 48 53 46 5.7 5.5 5.3 5.0 6.7 6.5 6.3 6.0 7.7 7.5 7.3 7.0 9.3 9.1 8.7 8.3 38 34 30 25 43 39 35 30 48 46 41 38 58 54 48 41 20 27 30 25 23 32 35 30 25 35 41 36 33 45 48 41 SA36 -E SA42 -E SA48 -E SA61 -E s Ratings era gross capacities - for net capacity, deduct evaporator blower motor heat, KW x 3.415 = MBH Of not included in alleviated load). a At 80 F DB air on evaporator. For each degree decrease in DB temperature, decrease sensible capacity by 1.1 MB14/1000 CFM; for each degree incrust, increase sensible capacity by 1.1 MBH /1000 CFM. 3 Includes compressor KW and t h e following KW for condenser and evaporator moron: Cond. KW Ivan. KW .4 .6 . . 8 YORK DIVISION SORG- WARNER 206 361 0424 P.04 /11 6.3 6.1 5.8 5.5 7.4 7.2 7.0 6.7 8.4 8.2 8.0 7.7 10.2 10.0 9.6 9.1 3 DEC -05 -2002 10:48 Model SA366080.18E SA366080.10E SA36G08025E SA36G105 -18E SA36GT05.10E SA36G105.25E SA366120.18E SA3BG 120.10E SA36G120 -25E SA42G120.18E SA42G120 -10E SA42G120 -25E SA42G12046E SA48G120.1BE SA48G120.1OE SA486120.25E SA48G12048E SA48G120 -68E SA61 6160-6E SA61 G160-25E SAM 6160.46E SA61 G160-58E Power Supply 208.1.60 230.1.60 208/230.3.60 208 -1 -80 230-1 -60 208/230.3.60 208.1.60 230 -1-80 208/230.3.60 208.1 -80 230.1.60 208/230.3.80 460.3.60 208.1.60 230.1.60 208/230.3.60 460.3.60 575-3-60 208/230-1-80 206/230 -3-60 460.3.60 676 -3 -60 ', PRO- , TAFF MECHAN I CAL Comp. F LA High Medium Low 2396 2336 2216 2160 2020 1955 �•e!: d• ',. I,',I, It i.l�l 1. I�Li, '':!•:• R., r( I. ,; ,).. elF �'Blowpr�;r.! ; Av4i bli itt�rriel Stitjc Ii -OWO 0.6 j, 0 : I 0.7 I. 0.8 High - 1 1950 1910 1860 1800 1740 1670 LB Medium 1880 1830 1790 1745 1690 1620 1510 Low 1710 1680 1840 1580 1530 1445 1300 2170 2060 1960 1850 1760 1650 24.1 21.8 14.2/12.8 24.1 21.8 14.2/12.8 24.1 21.8 14 . 27.1 23.7 18.6/15.0 8.0 31.0 28.0 18.4/16.6 9.0 7.2 38.0/34.4 23.2/21.0 10.5 8.0 Evap. Motor FLA 3.6 3.1 3.6/3.1 3.3 3.0 3.3/3.0 3.3 3.0 3.3/3.0 4.6 4.2 4.6/4.2 4.2 5.9 6.1 5.9/5.1 5.1 5.1 7.5/6.8 7.5/6.8 6.6 6.6 Cond. Fan FLA 2.3 • 2.0 2.3/2.0 2.3 2.0 • 2.3/2.0 2.3 2.0 2.3/2.0 3.8 3.2 3.6/3.2 1.6 4,6 4.2 4.6/4.2 2.1 2.1 4.6/4.2 4.6/4.2 2.1 2.1 Venter Minimum Fan Circuit Watts Ampacity 65 40 I 60 35 60 25/25 35/30 40 60 35 50 25/25 35/30 40 60 35 50 26/26 35/30 45 60 40 60 30/30 46/40 16 20 50 80 45 70 35/30 50/45 20 20 15 15 60/55 90/80 45/40 60/50 20 25 20 20 206 361 0424 Maximum 'Minimum Fuse Wire Size Size 60 ° C 6 8 10/10 14 6 8/10 12 12 ,._. 4/6 6/8 12 12 P.0 / 11 Z DC w 00 (.0 OD W W = F- W LL Q a W z F- Z LIJ D 0 O-- 0 F- w 2C F- H UL O . Z W U= O Z Ammrma Ana rn 411111 AIM I- '.• ., : .t..k :•,'!:'.. I t • • .___ •:1 4 i,: . ',4s.r. .: c .., Plenum-Supply and Return Duct Diffuser Economizer 1 1 1 20 24 1 1 16 x 25: 1 20 x 2Sx 1 430 490 I I- z • W O 0 0) 0 U) ILI W I _I 1— U) u. w 0 g • < w z I-0 z WW I— w z uj n 0 o O - • 0 L -!- - 0 O • I— DEC -05 -2002 10:53 UNIT DIMENSIONS 1/2 7/18 HOLE 3/4 ACCESS PANEL 3-1/4 1" NPTE GRAIN KNOCKOUTS FOR POWER WIRING 16/16 36" REAR CLEARANCE 36" SIDE CLEARANCE al PRO —STAFF MECHANICAL 6-5/16 4 PT, TOP CLEARANCE A • 206 361 0424 P.07/11 36" SIDE CLEARANCE 2 /1 33• /4•• 20.3/4 24-1 /2 400 13 -1/8 430 430 1 -1/8 1.3/8 4-1/2 ACCESS PANELS 3.1/2 HOLE FOR 1/2 NPTI GAS CONNECTION TRIC DIFFUSER DIMENSIONS ACCESS PANEL 7/8 HOLE FOR CONTROL WIRING 6.5/18 SA36G080 SA38G105 54 15.7/8 101380120 5A420120 A483120 70 21-7/8 : A61 G160 464/8_ 28 ' • Intl udes support channel extension. ••I ncludes support channel.(o /e height dim.) 1 30 lbs. for 460 -3.60 units. 29.1/2 141/8 YORK DIVISION BORG - WARNER L DEC -05 -2002 10:54 PRO —STAFF MECHANICAL PLENUM, PLATFORM AND EC IZER DIMENSIONS I YORK DIVISION BORG•WARNER El 12 DIMENSIONS - INCHES ACCESSORIES ROOF MOUNTING CURB DIMENSIONS 1 -5 /S G 1- C 1-6/8 r- ROOF CUT OUT 1 206 361 0424 P.08 /11 ECO = IZER ON FOAM 630.01602 r '1' iiLU.•lil o SA -3E t.® 23- 30-1/4 PF /SA•6E '17.3/4 27.7/8 28.1 /4 we— W oT AVAIL,N5Le. 7 4M ..•t+w^�v.4lisifv�`masR .eiai1m4.0CAvu.iw if :13 47 , z • w 6 .J U O 0 CO 0 w w j • CJ � w z � 1-- 0 z I- w w 0� O N 0 - w I = - r- - O w Z Uco O ~ z DEC -05 -2002 10:55 TYPICAL INSTALLATION ECONOMIZER PLENUM AND PLATFORM ACCESSORY FLUSH-MOUNT CONCENTR IC DIFFUSER PRO —STAFF MECHANICAL York Division of Borg.Wernn Corp., P.O. Box 1602, York, Pr. 17405 SUBJECT TO CHANGE WITHOUT NOTICE ►IIINTIO IN U.S.A. INT 20M 676 .25 Cods: E(U1) & Elal Form 530,09.562 E(YCI, CMP - Int. 60 Hz TO GAS SUPPLY ti YORK ■ ■ 206 361 0424 P.09/11 FUSED DISCONNECT SWITCH TO POWER SUPPLY THERMOSTAT CONTROL WIRING TO INDOOR THERMOSTAT Unit Model No. and ROMs Air Gr010 Modd No, *BCD �iffi+ H J GCS3411 -413 + F041-0 IAdj. Baffle Blades) 24 22 16 18 sq. ft. 29.3/4 0083411413 GGS3d81�63 FOa86 FD-680D (Ad). Piffle Blades) 30 22 16 91 3 q. ft. 363/4 —. lea tUMURN aft •raPTtao -No �iffi+ ...314 +3K ..-15%—.. u s . 21 . „` ! • / i DEC -05 -2002 10:57 ti inMFLOw Pc,EHum Rs Fve.arica. ss lmAlzA TRANSITION 11S0UI9ED (not lurniduidl C1aCtopttD TRANSITION REQUIRED (not*MOW © 1 314 -* 16E-0 mum sums FRONT VIEW PRO -STAFF MECHANICAL DIMENSIONS (in.) - 16 16 4 /LLttltl eaaaaaoa am OMAN vlela afghans ar lIA O orle•AL ar t1aLOIQaa COWRIES INTAKE MN C O 130 , 129 190 X00 PLUSH CEILING GRILLE A It A 141-� X G w<fpty 1 • 1411--G C-01 Flamm Air CORNER WEIGHTS (Ibi.) NOTE -AIN) aaallMNe wltK 1/1014 IIYurtmwlt Law aInandom w above, OPTIONAL OAD3•46 MINIMUM FRESH AIR DAMPER YAN1l■L DAMIEN AINEAwLT I INCH PIN CON i TON V ♦♦ ■ 5 E VIEW non -Noon Mail rnam P. amine/ WINN aMIMi e1 IWIRm, - R ar•e aaw a.a 7Y r Va -U T.TaY 6014 • •OTI■O.ra mina rw. IlK 154 170 .44, — 230 -"to - 238 1111111M-11111 MIMI NMI 'NAME rw.l.a.a rw tram ...wayl POOP MO IYr ..Ir .4- ax• wr r I..uU— Nolo .oar IPaI wnt� Purr a -oa Ir i- -.•. ,URNACI Acnaa INDI 206 361 0424 P.10/11 ■ORV +aT i Ti MP CENTER OP GRAVITY 9% 10%m Unit a • Basle unit 33-1/4 With FITS With ROB II 19 32 -3/4 23-7/0 31 28 -1 /B RTD41 STEP DOWN GRILLE 201 Z0 Ra1um Air — eel 2412 (y 20 a 5 Supply Alr 0rIllu Punished III 20 120Ralum Ab Onlh finished RECOMMENDED FLASHING FOR RMF3 ROOF MOUNTING FRAME aNau /A UNIT IMLIN NA1tAMI.'”' war lICUIM. 80LTI_ 9 GA, CCOUM amdiNAOMI Fa LINT MIN 16 1 16 to 20 1 TRANSITIONF NoTI- AMAOvto IT NATIONAL ROOMS CONT1ACTCIa AIIOCIATION 13 woo IIL{ILAIICN NAttk Iaa7 MOUNTING PRANG ErrEtaf L f aoO/IN NAIWM ti ` };.: -Awci ikluirtiON MAI 1101460111 L tve u IOIPLT AIR or011110 26 tUMURN aft •raPTtao �iffi+ ...314 +3K ..-15%—.. . 21 <II DEC -05 -2002 10:57 ti inMFLOw Pc,EHum Rs Fve.arica. ss lmAlzA TRANSITION 11S0UI9ED (not lurniduidl C1aCtopttD TRANSITION REQUIRED (not*MOW © 1 314 -* 16E-0 mum sums FRONT VIEW PRO -STAFF MECHANICAL DIMENSIONS (in.) - 16 16 4 /LLttltl eaaaaaoa am OMAN vlela afghans ar lIA O orle•AL ar t1aLOIQaa COWRIES INTAKE MN C O 130 , 129 190 X00 PLUSH CEILING GRILLE A It A 141-� X G w<fpty 1 • 1411--G C-01 Flamm Air CORNER WEIGHTS (Ibi.) NOTE -AIN) aaallMNe wltK 1/1014 IIYurtmwlt Law aInandom w above, OPTIONAL OAD3•46 MINIMUM FRESH AIR DAMPER YAN1l■L DAMIEN AINEAwLT I INCH PIN CON i TON V ♦♦ ■ 5 E VIEW non -Noon Mail rnam P. amine/ WINN aMIMi e1 IWIRm, - R ar•e aaw a.a 7Y r Va -U T.TaY 6014 • •OTI■O.ra mina rw. IlK 154 170 .44, — 230 -"to - 238 1111111M-11111 MIMI NMI 'NAME rw.l.a.a rw tram ...wayl POOP MO IYr ..Ir .4- ax• wr r I..uU— Nolo .oar IPaI wnt� Purr a -oa Ir i- -.•. ,URNACI Acnaa INDI 206 361 0424 P.10/11 ■ORV +aT i Ti MP CENTER OP GRAVITY 9% 10%m Unit a • Basle unit 33-1/4 With FITS With ROB II 19 32 -3/4 23-7/0 31 28 -1 /B RTD41 STEP DOWN GRILLE 201 Z0 Ra1um Air — eel 2412 (y 20 a 5 Supply Alr 0rIllu Punished III 20 120Ralum Ab Onlh finished RECOMMENDED FLASHING FOR RMF3 ROOF MOUNTING FRAME aNau /A UNIT IMLIN NA1tAMI.'”' war lICUIM. 80LTI_ 9 GA, CCOUM amdiNAOMI Fa LINT MIN 16 1 16 to 20 1 TRANSITIONF NoTI- AMAOvto IT NATIONAL ROOMS CONT1ACTCIa AIIOCIATION 13 woo IIL{ILAIICN NAttk Iaa7 MOUNTING PRANG ErrEtaf L f aoO/IN NAIWM ti ` };.: -Awci ikluirtiON MAI 1101460111 L tve u Unit W Evaporator Air O Outdoor Air Temperature E Entering Condenser IF) k k. 85 9 95 1 105 1 115 ; sintering � Total T Total t tensible C Comp, T Total S Sensible C Comp, T Total S Sensible C Comp. T Total S Sensible C Comp. ' � � Net face area (sq ft) 3,75 Cooling Capacity AR1 Certified Modal No. Condenser Net face area Isq ft) Coil Tube diem. (In.) & No. of rows Firs per inch Diem. (In.) & No. of blades Evaporator Tube diem. (in.) & No, of rows Coil GCS3.411.80 GCS3- 413-80 0063.411 -120 OCS3- 413 H eating capacity input 18tuh) 80,000 120,000 Heating capacity bonnet output (Btuh) 60,000 90,000 Total capacity ((Ruh) 37,000 t t42,000 • Total unit watts 5600 116300 Dehumidifying capacity 26% 25% Blower wheel nom. diem. x wld. (in.) (2) 9 x 7 (2) 9 x 7 • lower Motor hp. Refrigerant (R -22) charge 1/2 8 lbs. 1/2 8 lbs. 5 oz, 13 13 5.73 1/2-3 6,88 1/2-3 Fan Motor hp 1/4 1/4 20.4 20 -4 Condanasr Air volume (factory letting) 2600 2500 Motor watts (factory setting) 450 1/2 -3 Fins per inch 10 •No. & size of filters (in.) (1) 28 x 28 x 1 Oas supply connection MPT (in.) (nat. & propane) 1/2 Recommended gas supply Natural pressure WC (in.) Propane Optional Combination Ceiling Supply And Return Flush Diffuser FD-41 - •24 lbs. •FD•41 -D - '30 lbs. FD•65 - •26 lbs. •• • •65.0 - •33 Ibs• Daum la e.F1 NLB r i GCS3. 461410 GCS3.463.50 80,000 60,000 GCS3.461.120 C 83-83 - 120 120,000 90,000 450 4.58 1/2 -3 10 (1) 28 x 28 x 1 1/2 6 6 Condensate drain size FPT (in.) 3/4 3/4 11 1 1 Net weight of basic unit Obi) 11 •Pkg,) Optional Combination Ceiling Supply And Return Step Down Diffuser 640 9TI3-41 - •35 lbs. 670 RTD -41 - •36 lbs. • FD-65 - •26 lbs. ••FD•65 -D - '33 lbs. RT8.46 - •100 lbs. RD8 lbs. Optional Roof Mounting Frame RMF3.48 - • 100 lbs. Optional Minimum Fresh Air Damper 0403 -46 - •7 lbs. c 4.. •i DEC -05 -2002 10:57 PRO -STAFF MECHANICAL I ;j it AF Optional Duct Enclosure (Without Power Saver) Optional Ouct Enclosure with Power Saver & controls installed .r.r.v7r1.+? 4 VMV SIMVW 1 fi t?s •i P.47A4 a147.!r,-9?o err rw I • ; r te • II �'I �.. r:,+", ;�.._ �i�•�•1 �.�'.', - r�. r ;^: `„�- �- '•,..*••, ,. r ,• I .r � -� � • • 1 �t,l' .t�rY:: i•:,�' ..�i�.:'•. L�J'•:• c� .,FJ�i.y� ^�ril��.- �� •t�J'rir,"� l� tfr: 0(!F logl.$ph.Ie - S k t R � , � ' s i r? ;.;•fY � �•, � � � 1. . = � j �l: y'f:.' .. :N �i�� �_I ��1:.• " 1•.r � 1 �� = sr: • SPECIFICATIONS 206 361 0424 : Atv L , � `aI�ISti�L91 ^l: f� t�i f10 R„1'! .., : - r � • � e.'t� j i r e '�''. �� • •{.� ( t ti State of Wash injtot County of_ ' --- T'certiffin his Ts a ri indi correct copy or a document i the pos sessioq of Dated: -4 0e . t ; aR tt (Signature of Notary Public) et �' .• c c a .`Jiy� ! / -•. ' (Sea7L8f•.Sta "i I .i;. if 1 as of This date. (K / V : Title ,, ��! fir• ., • � Qr • My appointment expires '7 ' 1 O� 6 REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # EXP. DATE CC01 PROSTMI072NG 06/30/2004 EFFECTIVE DATE 08/07/1993 PRO STAFF MECHANICAL INC PO BOX 33370 SEATTLE WA 98133 LICENSED AS PROVIDED BY LAW AS ELEC CONTR HVAC /RFRG LICENSE # EXP. DATE O EFFECTIVEDATE006C8 002/28/2000 PRO —STAFF MECHANICAL INC PO BOX 33370 SEATTLE WA 98133 -8031 State of Wash n ton County of — T'certify�ia his Ts i ind correct copy or "' a ocusent in t possession of Kro Dated: .P • as of'thi date. r Ti tie e :U - - N: / : f? s0: o j y appointeent expires '7- �""0 b (Signature of Notary Public) CERTIFIED AS PROVIDED BY LAW AS ADMINISTR HVAC /RFRG CERT. # EXP. DATE AD6A HUGHEJ*008C8 07/22/2004 EFFECTIVE DATE 02/28/2000 HUGHES, JEFF 10617 NE 138TH PL KIRKLAND WA 98034 W 0 0 > co 0 W W W : COIL W D ? . u , , M U, N , 0 ,—, W W v . IL O' w Z O } n ; :y. : : •:., .•.• t. . .: tv... �.•'FZZ•: h•::: �::tw:.: :. : :, ;., .:: :: .:; :; •+,. • . .:.2 ... .. v .,•.,•: •., • }:. }. �: , : :•::5::•55} .t• 555 X5::5 :,n,:.a^•':;::� t „ ..,.. r. �, ,. .;+ .,•..... }•.� :: ? :....:.:::..:.5.:.•.v.,. , ..t•:t•5:• }Y}5 }: ?;.Y:•s:: 'v:{:r r:YS•'• ••i2::•2f. <i �: X 5 5 :.: a • . ..: , �V.hm:•r,:k•.•;Y:�.�:;:: yr .' l:. .+�'...: •..,�,r,.f,. •MtF`'% : . •Y,.. l,,, . . � . t t•: , : • ,:• .,t•$5. } • ■■ •• : S. yw ..:$ .v......:4,..:•,1••••:•••:.:•:.•• :, v:: t ' ...... ::4i % %: +t±: : i :tr i } 5 .::::} •r . „;: •:: +.• •}5 }}55:.:.:: <Y t::.. .......,. k .t•Y:.:r � +55:.:. ssssY:•5Y ::. .;.tt t•:d•vtt }: :: t: ? :.; .N}.. �::::.. •.., >, :.;•, }rL...,t:, }.: 3::a ^:::�•.• : ?;:i:y;;:i:;o'•.5•;; h:s: s •:$ :•.::v .:: .• R i�: 7t }i+ :.. +.•n . .• ^ . �:. . . $: :. /a -/I - ss: t.:•:t•;• };::.�c+:•5: +•: �•5:: •5 }: � •.:.;.}:., :..a nYY+ •;: '' r t e :: : a . a in. ;C: t ••: i4:, 5. x .. :.... ..,•:. • • L'.0 t�' :: r: L^:: hv:: Y :ihs } }: ^ti4 }: ^'t'S:.i: Yi: •. };:,, t�,,/3/"'"— Balance Due: $ 469 Need Current Contractor Registration Card: Need to Enter Contractor Information in Sierra: [ es ❑ No ❑ No z W 00 u) � LU W = H N u w u- co 1- W z� Z 0 CI 0 0- 0H W I I-- u. O ..z w U O E- z 35mm Drawing #1 I 1 . • 0 Inch 1/16 Sl File: M 02 -0220 ;t ft t 1. �` L� v L L l 0 IIII1IIIIIIIII1IIIIIIIII1IIIIIIIII1IIII IIII I I IIII�IIII �IIII .IIIIIIIIi,lllI 1111.1II 6 0:00,164,0,,,,,,t l�l� �r•P' pn� N hey 1 ROOF PLAN No Scale EQUIPMENT NOTES: 1. Factory installed Economizer. 2. Custom Curb Adapter. RooF. I4ATGH AC -1: REPLACE EXISTING 4-TON AC UNIT WITH A NEW TRANE 4 -TON AC UNIT. exi5rt 4( ,{ Wes, VALOEy N, wA-Y AC-1: NEW TRANE PACKAGED EQUIPMENT SCHEDULE 3. New Honeywell 7 -Day programmable night setback thermostat with 5 degree deadband capability. 4. Outside air intake to be 10' - 0" from exhaust outlet, gas flues & plumbing vents. 0 Inch 1/16 t ' I1111IIIIII111111III 111111111 IiIiI.1111I 111 111111111 63,000 l'ARlti' Loi SCOPE OF WORK: ❑ LIKE - FOR -LIKE CHANGE -OUT" = REPLACE ONE EXISTING YORK 4 -TON AC UNIT WITH A NEW 4 -TON TRANE AC UNIT R MCA = 25.3 ufgJSE =40 NTER Yap TAG MAKE AC- 1 TRANE MODEL # YSC048A1EIVIA SIZE CFM MIN OSA 4-Ton 1,600 400 COOLING (BTUH) 50,300 COOLING HEATING SEER INPUT 10.0 80,000 HEATING OUTPUT AFUE ELECTRICAL WEIGHT 208-230/1/60 (LBS.) 516 n fA.. T voir �'`, QI� l� pa I :_ • `:�a�'�17j..,, yy i! I�,J �1,•�.t•tin4,A\ A NEW G + A ' II E V IZI'OMS WILL REQUIRE A NEW PL7'6N MV MANY GMCLUDL AIDUIM rO PO RI I G I Et t9 F a;i,nSF,Y' buff. fit. r S" ;,•1 w� d LOCATION MAP No Scale --- COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved •k ns acknowledged. IIIIIIIIIIIIIIIIIIIIIIII, LIIIII111111Il1Ii11I11111I111111111I111111111I1111111IIl Permit.No. !Ito SEPARATE PERMIT REQUIRED FOR: 0 MECHANICAL [I ELECTRICAL E PLUMBING GAS PIPING CITY OF T U KWI LA BUILDING DIVISION MO 2- "%":: > •' % °dam � 'i i : R c CITY 0 NOV 4 I PERMI