Parcel No.: 3523049018
Address: 18292 ANDOVER PK W TUKW
Suite No:
Tenant:
Name: G E POLYMERE
Address: 18292 ANDOVER PK W, TUKWILA, WA
Owner:
Name: LA PIANTA LP
Address: PO BOX 88028, TUKWILA WA
Contact Person:
Name: ROBERT WEBB
Address: 6830 S 220 ST, KENT, WA
Contractor:
Name: COMFORT MECHANICAL INC
Address: 6617 S 193 PL, #P -105, KENT, WA
Contractor License No: COMFOMI015LA
DESCRIPTION OF WORK:
REPLACE ONE 3 -TON AND ONE 5 -TON SPLIT HEATPUMPS WITH ONE 3PTON GAS PACKAGE UNIT
AND ONE 5 -TON GAS PACKAGE UNIT, NEW DUCTWORK TO CONNECT FROM NEW ROOFTOP UNITS
TO EXISTING DUCTWORK
Value of Construction: $7,000.00
Type of Fire Protection:
Permit Center Authorized Signature:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit.
Signature:
Print Name:
doc: Mech
City of 1lk1a
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
MECHANICAL PERMIT
A /I,//J
Permit Number: MO2 -223
Issue Date: 12/13 /2002
Permit Expires On: 06/08/2003
Phone:
Phone: 425 251 -9840
Phone: 425- 251 -9840
Expiration Date: 06/01/2004
Fees Collected:
Uniform Mechnical Code Edition:
1/ Date: d 'iU '6Z�
Date: /z -/d —v Z
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
MO2 -223
$63.63
1997
Printed: 12 -10 -2002
ACTIVITY NUMBER: MO2 -223
PROJECT NAME: G E POLYMERE
SITE ADDRESS: 18292 ANDOVER PARK WEST
X Original Plan Submittal
Response to Correction Letter #
DATE: 11 -22 -02
Response to Incomplete Letter #
Revision # After Permit Is Issued
DEPARTMENTS:
Buildi : vi ion �]
Public Works ❑
PLAN REVIEW /ROUTING SLIP
,1 o /z-
Fire Prevention
Structural ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete u
Comments:
Documents/routing slip.doc
2.28.02
Incomplete
REVIEWER'S INITIALS:
Planning Division
Permit Coordinator
DUE DATE: 11 -26 -02
0
Not Applicable ❑
Permit Center Use Only
INCOMPLETE. LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS RO9TING:
Please Route Id Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
DUE DATE: 12 -24 -02
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
DATE:
Permit Center Use Only
CORRECTION. LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
re w
tno
�w
w
� Q
al
W
Z
1— 0
Z H
uj
0
0 1—
W W
H�
U. O
0-
1
z
1
DEPARTMENTS:
Building Division
Public Works
Complete 4
REVIEWER'S INITIALS:
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: MO2 -223
PROJECT NAME: G E POLYMERE
SITE ADDRESS: 18292 ANDOVER PARK WEST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
DATE: 11 -22 -02
Revision # After Permit Is Issued
APPROVALS OR CORRECTIONS:
Fire Prevention ❑ Planning Division ❑
Structural ❑ Permit Coordinator ❑
Incomplete
DUE DATE: 11- 26-02
Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route ❑ Structural Review Required ❑ No further Review Required
DATE:
DUE DATE: 12 -24 -02
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS: DATE: ti Z6
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2.28.02
Not Approved (attach comments) ❑
oz
PERMIT NO.: A90Z• ZZ 3
MECHANICAL PERMIT APPLICATIONS
INSPECTIONS
❑ 2 Pre - construction
❑ 50 WSEC Residential
❑ 60 WA Ventilation/Indoor AQC
❑ 610 Chimney Installation/All Types
❑ 700 Framing
❑ 1080 Woodstove
1090 Smoke Detector Shut Off
1100 Rough -in Mechanical
❑ 1101 Mechanical Equipment/Controls
❑ 1102 Mechanical Pip/Duct Insul
❑ 1105 Underground Mech Rough -in
❑ 1115 Motor Inspection
1400 Fire - Final
1800 Mechanical - Final
❑ 4015 Special -Smoke Control System
CONDITIONS
iE 10001 No changes to plans unless approved by Bldg
Div
10002 Plumbing permits shall be obtained through King
Co
10003 Electrical permits obtained through L & I
❑ 10005 All permits, insp records & approved plans
available
8 10014 Readily accessible access to roof mounted
equipment
❑ 10016 Exposed insulation backing material
▪ 10019 All construction to be done in conformance
w /approved plans
• 10027 Validity of Permit
• 10036 Manufacturers installation instructions required
on site
❑ 10041 Ventilation is required for all new rooms &
spaces
❑ 10042 Fuel burning appliances
❑ 10043 Appliances, which generate....
❑ 10044 Water heater shall be anchored....
Additional Conditions:
TENANT NAME: 6 E f.. yo n ,, 4.-
FEES
Basic Fee (Y/N)
Supplemental Fee (YIN)
Plan Check Fee (Y/N)
FumaceBumer
to 100,000 BTU (qty)
Over 100,000 BTU (qty)
Floor Furnace (qty)
Suspended/Wall/Floor-mounted Heater (qty)
Appliance Vent (qty)
Heating/Refrig/Cooling Unit/System (qty) —
Boiler /Compressor
to 3 HP /100,000 BTU (qty)
to 15 HP /500,000 BTU (qty)
to 30 HP/1,000,000 BTU (qty)
to 50 HP /1,750,000 BTU (qty)
over 50 HP /1,750,000 BTU (qty)
Air Handling Unit
to 10,000 cfm (qty)
over 10,000 cfm (qty)
Evaporative Cooler (qty)
Ventilation Fan (qty)
Ventilation System (qty)
Hood (qty)
Incinerator — Domestic (qty)
Incinerator — Comm /Ind (qty)
Other Mechanical Equipment (qty)
Other Mechanical Fee (enter $$)
Add'I Fees — Work w/o Permit (Y/N)
Insp Outside Normal Hours (hrs)
Reinspections (hrs)
Miscellaneous Inspections (hrs)
Add'I Plan Review (hrs)
Plan Reviewer: Date: tL IS 6 1° Z
Permit Tech: b V \ Date: 1 1-2 7-0.
ACTIVITY NUMBER: MO2 -223
PROJECT NAME: G E POLYMERE
SITE ADDRESS: 18292 ANDOVER PARK WEST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
DATE: 11 -22 -02
Revision # After Permit Is Issued
DEPARTMENTS:
Building Division
Public Works
Complete ❑
PLAN REVIEW /ROUTING SLIP
Fire Prevention
❑ Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete
Planning Division
Permit Coordinator
DUE DATE: 11-26-02
Not Applicable ❑
Comments:
Permit. Center. Use. Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route ❑ Structural Review Required ❑ No further Review Required KY
REVIEWER'S INITIALS: g DATE: / 216 - Z
APPROVALS OR CORRECTIONS:
DUE DATE: 12 -24 -02
Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documentshouting slip.doc
2 -28.02
Project Name /Tenant:
Cr E ?o\' 1A4enr
Value of Mechanical Equipment:
# 7 000.00
Site Address : City State/Zip:
v .'r k , ,\cv� ‘04 WA °( O p p'
1 S a,cla Av�pve t''u We�� c. \4
Tax Parcel Number:
Property Owner:
Date:
Phone: ( )
Print name: RO ./C l.ti3e✓b\:*
Street Address:
$\ C
City State/Zip:
Fax #: ( )
Address:
G 830 Sou.*■■■ 'a.lo Street
Contractor:
covyI .qo•' ■tC0n0.v►■ Co. \
fi
, t,...) 6 98o-3-a.
Phone: (tiz,s5)
a5 `_ 9 gy0
Street Address:
c, Ino ¶ . a�c:Pv S� . le
t L.0 A-
City State/Zip:
9 8 o3a
Fax #: (. )
as
a5 \ - a 8 �
Contact Person:
Robe -Ct 1,J.2b•
Phone: ( )
a la s
a.S\ - Q$y0
Street Address:
6830 s• a •o i " ` S
City State/Zip:
KcAAA, w A 9':3(-53
Fax #: ( )
`fa.s
S \ R 1
4UILDING'OWNER ORAUTHORIZED.'AGENT.`:
Signature: /7
Date:
d(
Print name: RO ./C l.ti3e✓b\:*
Phone: (9...1:s.)
$\ C
.10
Fax #: was asl_ 1
Address:
G 830 Sou.*■■■ 'a.lo Street
City /State/Zip:
k
fi
, t,...) 6 98o-3-a.
CITY OF TL XWILA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
Project Number:
Permit Number.
/ '7D07 -,
SIAI I lUSI ()NI V
Mechanical Permit Application
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT)
Description of work to be done (please be specific):
Re_I-No cg-
t.-01.1-V1 o +n�
p ckcacS<
Ytc.� roc*1c3
r)v► - - \ o v.
4
ovVq
S- - Cov.‘
ut �
"s- 1 c " 0.S 14cky._
"avl∎ , v,et,J d>,�Ct� A
LAMI iA'S 4-o c oNc`c
1ne0A
5= �'n✓�
Qv'owi.
Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of
application, a copy of this license will be required before the permit is issued OR submit Form H "Affidavit in Lieu of Contractor
Registration ".
Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the
State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the
permit will be required as part of this submittal.
1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written
request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be
extended more than once.
Date application accepted:
l / - 4. 2 / az
Date application expires:
,5 =2 / -03
Application taken by: (initials)
09/10/2002
✓
Submittal Requirements
Floor plan and system layout
Roof plan required to identify individual equipment and the location of each installation (Uniform
Mechanical Code 504 (e))
Details and elevations (for roof mounted equipment) and proposed screening
Heat Loss Calculations or Washington State Energy Code Form #H -7
H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut-
off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical
Code 1009).
Specifications must be provided to show that replacement equipment complies with the efficiency ratings
and other applicable requirements of the Washington State Nonresidential Energy Code.
Structural engineer's analysis is required for new and the replacement of existing roof equipment
(including commercial kitchen hoods) weighing 400 pounds and greater (Uniform Building Code
1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer.
08/10/2002
miscpmt.doc
New Single Family Residence
Change -out or replacement of existing mechanical equipment
Narrative of work to be done, including modification to duct work.
Installation of Gas Fireplace
Mechanical Permits
COMMERCIAL: Two complete sets of drawings and attachments required with application submittal
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced.
RESIDENTIAL: Two complete sets of attachments required with application submittal
Submittal Requirements
Heat loss calculations or Form H -6.
Equipment specifications.
Narrative with specification of equipment and chimney type.
If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe
condition.
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being- installed or replaced.
Parcel No.: 3523049018
Address: 18292 ANDOVER PK W TUKW
Suite No:
Tenant: G E POLYMERE
Signature:
Print Name:
doc: Conditions
City of Tukwila
PERMIT CONDITIONS
MO2 -223
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Permit Number: MO2 -223
Status: ISSUED
Applied Date: 11/21/2002
Issue Date: 12/10/2002
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division.
3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be
inspected by that agency, including all gas piping (296- 4722).
4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical
work will be inspected by that agency (206- 835 - 1111).
5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any
construction. These documents are to be maintained and available until final inspection approval is granted.
6: Readily accessible access to roof mounted equipment is required.
7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997
Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition).
8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be
construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any
other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this
code shall be valid.
9: Manufacturers installation instructions required on site for the building inspectors review.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work.
Date: 1.2 —/& - '-
Printed: 12 -10 -2002
Parcel No.: 3523049018 Permit Number: MO2 -223
Address: 18292 ANDOVER PK W TUKW Status: PENDING
Suite No: Applied Date: 11/21/2002
Applicant: G E POLYMERE Issue Date:
Receipt No.: R020001721
Initials: KAS
User ID: 1684
Payee: COMFORT MECHANICAL
TRANSACTION LIST:
Payment Check 6098
ACCOUNT ITEM LIST:
doe: Receipt
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Current Pmts
Amount
MECHANICAL - NONRES
PLAN CHECK - NONRES
Type
RECEIPT
Method Description
Payment Amount: 63.63
Description Account Code
000/322.100 50.90
000/345.830 12.73
Payment Date: 12/10/2002 02:07 PM
Balance: $0.00
63.63
Total: 63.63
32901'2/11 9716 TOTAL 63.63
Printed: 12 -10 -2002
� W
UO
N 0 .
u.
NW
W O:
g Q '
O
ju
2
C U ;
O
0 H
W
I-- -
O;
V
Pr ect: /
:1 i Pio /1!/»er?
T •e of lnspectio • f
'�; �� wtc. c�1r.fI/l�it/i
A dress
( 9 -- /'' /,
Tate Called:
- in - a3
ecial Instructions: p `
r 7 "G It" L / ,m
Date W .rated:
�/ - O 3
.m.
11C
Requq
Phone No:
INSPECTION RECOf m
Retain a copy with permit
INSPECTION NO. PERMI
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
COMMENTS:
rr ► m I - q reweel
/e
v14 C . . Sky co t.4." - Or () J 7'7�J Po
c.1. f' 044'1� oWI,k
O � - - \ - z, I nA
Approved per applicable codes. Corrections required prior to approval.
$47.00 REINSPECTION FEE REQ IRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
Z
W
00
co a
UJ
Co
W
u.
�d
zF
IIJ W
U�
0 N,
o l-
W
O
.. Z
W
=
O F-
pprovedper'applicable codes.
INSPECTION RECO
Retain a copy with permit
INSPECTION NO
ITY OF:TUKWILA BUILDING DIVISION
300: Southcenter Blvd., #100; Tukwila, WA 98188
b -aa3
PER
N�
(2 • . 431 -3670
Address:,,:
Special Instructions:
Type of Inspec 'on:
ugh- (4v
Date Called:
/2 - 1O - 0Z
Date Wanted:
1aIr o)% p.m.
Request g:
Phon No:
a 06 , 3 -3 8
El Corrections required prior to approval.
COM
C/2-!-7.
Date:
REI■SPECTION EE REQUIRED. Prio to inspection, fee must be
at;t300 Southcen r Blvd., Suite 100. Call to schedule reinspection.
ec I • t No. 'Date:
�? ;'? "77ti.r+r�i•:f ,^R'... sl" .r..yf. ��*.T� „ r, 4 S :�F" �,� 4 Z - it 7 ,I.. •IN�, r.
City of Tukwila
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
pp cn/2
Addre
Project Name
( Approved without correction notice
Approved with correction notice issued
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre -Fire:
Permits:
F
a,G( ((.
Authorized Signature
r
FINALAPP.FRM Rev. 2/19/98
Steven M. Mullet, Mayor
Fire Department Thomas P Keefe, Fire Chief
Permit No.
Suite #
//, 3A
Date
/ Retain current inspection schedule
X 71 Needs shift inspection f / Gi6//1 5-/-7U7--46/1 5-/-7U7--46/1 l
T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439
I understand that the Plan Check approvals are
subject to errors and omissions and approval of
plans does not authorize the violation of any
adopted code or ordinance. Receipt of con-
tractor's copy of approved plans acknowledged.
By
Date
Permit Na
o
" y
•
FILE COPY 4
t
SEPARATE PERIL
REQUIRED FOR:
❑ MECHANICAL
1 ELECTRICAL
Rs PLUMBING
[� GAS PIPING
CITY OF TUKWILA
BUILDING DIVISION
0'
0
O
CITY Of TUKWILA
APPROVED
C!N pF TUKWILA
NOV 2 1 2002
PERMIT CENTER
DEC 0 6 2002
AS WAD()
o N G D M V O N
/SUZ3
NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN
THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT.
ENW ENGINEERS NORTHWEST, INC., P.S. ^' STRUCTURAL ENGINEERS
6869 WOODLAWNNAVE. N. E., #205, SEATTLE, WA 98115 (206) 525-7560 FAX (206) 522 -6698
PROJECT # 02 (Do: In- PROJECT at e 1;61.1 �i 741 DATE PV/2/0
A
SUBJECT
.,r
4%4 Drtz
wgcm> 14 };{as,
£r )
IL X3o l gLg
SHEET 1 OF 2
BY
CITY OF TUKWIIA
APPROVED
DEC 0 6 2002
AS WIk.
DNG DiTf3?ON
RECEIVED
CITY OF TUK1nnl
IkOV212
PERMIT CENTES
2
Utsrg s o -nwr LO, p Im . S r 4ia,4 LL L- TO CILJ .
2, rae lal-o 106 Af2-c D oj*.. S AIL TL1'V D tDe5
s/ coL. t(1." •4.
s„ v l r t,m;-? I1J 6 8e � — `f 1Ca ti ,
4 , C1'1- Ve12 I4 o Oxt sir . ►' , - k K
e N - t% 2' .
o r -G 1 Q r►r - f 0 or 41 c--00r-
4
ENW ENGINEERS NORTHWEST, INC., P.S. — STRUCTURAL ENGINEERS
n
PROJECT # O , DO • I PROJECT £s' FvAU: C1 N1M 1-14- P. 74 1 DATE IINO
SUBJECT %eGTI As SHEET 2 OF Z
By /-
r r�C, w-1- ley
FiTl?
6869 WOODLAWN AVE. N. E., #205, SEATTLE, WA 98115 (206) 525 -7560 FAX (206) 522-6698
UN IT FE
EXPIRES 7/26/ nN
J
- -2 - "4 xsN
/ • 1,6-C SC,R.:EwS
LS . si13C of Ur) Ir
G - r'rl =1 .
is E uJ 4 A
LU4S 4
,s-tIcef CAP)
TRANE®
- ?ov vvt e,,ce.
I e Xci k IndoJeds L.De.st
7 \ 1..pz
FILE COPY
1
I unclerst:71nd thal the Phn anr7nvls r
Packaged Gas/Electric
Rooftop Units
PrecedentTM
3- 10Tons — 60 Hz
CITY Of TUVAA
PaPPROVED
Ysc_ oGc)At4
DEC
t'eJ
NOV 2 1 2002
PE N/vii7
October 2001 RT-PRC006-EN
MO2423
‘prpmet/PrWrIVIreerViltiWPW3.19iNRWAY 'P'J■S'V',S,tr~Wrmt<<rnr.V14v.rt'r,Vf",?!KR401'PIPR,I'r,,V,A,U+ass,wr,,,-.,....,,,,,, V! W.,,,,ti,, W, •
z
W
0
co o
W • I
—I E—
U) u_
W O
co
u.
I - W
z 1 ._
• o
z
UJ
D c
u j
o
o
w w
I
o
z
0
- I
o 1-
z
Table GD-2 - General Data
Cooling Performance'
YSC060A1
General Data
5-Ton Convertible
TRANE°
(5 - 6 Tons)
Standard Efficiency
6-Ton Convertible
YSC060A3, A4, AW YSC072A3, A4, AW
Gross Cooling Capacity 63,100 63,100 72,000
EER/SEER' -/9.90 - /10.20 10.1
Nominal CFM /ARI Rated CFM 2,000/2,000 2,000/2,000 2,400/2,100
ARI Net Cooling Capacity 60,000 60,000 68,000
Integrated Part Load Value' - - -
System Power (KW) 6.86 6.78 6.73
Heating Performance'
Heating Models Low Medium High Low Medium High Low Medium High
Heating Input (Btu) 60,000 80,000 130,000 60,000 80,000 130,000 80,000 120,000 150,000
Heating Output (Btu) 47,000 63,000 103,000 48,000 64,000 104,000 64,800 97,200 121,500
AFUE %' 81 81 80 81 81 80 81 81 81
Steady State Efficiency ( %) 81 81 80 81 81 80 81 81 81
No. Burners 2 2 3 2 2 3 2 3 3
No. Stages 1 1 1 1 1 1 1 1 2
Gas Connection Pipe Size (in.) 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4
Compressor
NoJType 1 /Climatuff® Scroll 1 /Climatuff Scroll 1 /Climatuff Scroll
Outdoor Sound Rating (dB)' 83 83 90
Outdoor Coil -Type Lanced Lanced Lanced
Tube Size (in.) OD 0.3125 0.3125 0.3125
Face Area (sq ft) 8.81 8.81 13.88
Rows/FPI 2/17 2/17 2/17
Indoor Coil -Type Lanced Lanced Lanced
Tube Size (in.) 0.3125 0.3125 0.3125
Face Area (sq ft) 5.00 5.00 9.89
Rows/FPI 3/16 3/16 2/16
Refrigerant Control Short Orifice Short Orifice Short Orifice
Drain Connection NoJSize (in.) 1/% NPT 1/3/4 NPT 1/3/4 NPT
Outdoor Fan -Type Propeller Propeller Propeller
No. Used/Diameter (in.) 1/22 1/22 1/26
Drive Type/No. Speeds Direct/1 Direct/1 Direct/1
CFM 3,470 3,470
No. Motors/HP 1/0.33 1/0.33 1/0.70
Motor RPM 1075 1,075 1,075
Direct Drive indoor Fan -Type FC Centrifugal FC Centrifugal N/A
No. Used/Diameter (in.) 1/11 x 11' 1/11 x 11 N/A
DriveType/No. Speeds Direct/2 Direct/2 N/A
No. Motors 1 1 N/A
Motor HP (Standard/Oversized) 0.90/1.00 0.90/1.00 N/A
Motor RPM ( Standard /Oversized) 985/1,080' 985/1,080' N/A
Motor Frame Size ( Standard /Oversized) 48/48 48/48 N/A
Belt Drive Indoor Fan -Type - FC Centrifugal FC Centrifugal
No. Used/Diameter (in.) - 1/11 x 11 1/12 x 12
DriveType/No. Speeds - BeltNariable Sheave BelWariable Sheave
No. Motors - 1 1
Motor HP ( Standard/Oversized) - 1.00/- 1.00/2.00
Motor RPM (Standard/Oversized) - 1,750/ - 1,750/1,750
Motor Frame Size ( Standard/Oversized) - 48/- 56/56
Filters -Type Throwaway Throwaway Throwaway
Furnished 7 Yes Yes Yes
(No.) Size Recommended (2) 20 x 25 x 1" (2) 20 x 25 x 1" (4) 16 x 25 x 2
Refrigerant Charge (Lbs of R -221' 4.9 4.9 7.1
NOTES:
1 -7. See Notes on Page 12.
8. YSC060A Oversized Motor Fan Diameter is 12 x 11.
9. Motor RPM shown is low speed. High speed RPM Is 1100/1135.
10. Filter size shown Is for low and medium heat models. High heat model filter size recommended is 20 x 30 x 1.
RT-PRC006 -EN 13
RTPRC006 -EN
All dimensions are in inches /millimeters.
3, 4, and 5 Ton Standard Efficiency — Low and Medium Heat
3 and 4Ton High Efficiency — Low and Medium Heat
EVAPORATOR SECTION
ACCESS PANEL
ALTERNATE CONDENSATE DRAIN
CONNECTION 3/4.14 NPT DIA. HOLE
3, 4, and 5 Ton Standard Efficiency —High Heat
3 and 4Ton High Efficiency — High Heat
5Ton — High Efficiency — Low, Medium, and High Heat
EVAPORATOR SECTION
ACCESS PANEL
ALTERNATE CONDENSATE DRAIN
CONNECTION 3/4.14 NPT DIA. HOLE
Dimensional
Data
4 1/4'
106 MM
12 NPT GAS CONNECTION
4 1/4'
108 MM
239/18'
598 MM
897/8 421/4'
1749 MM 1073 MM
~ 239/10'
598 MM
697/8 421/4'
1749 MM 1073 MM
1/2 NPT GAS CONNECTION
5 5/8'
143 MM
95/5'
244 MM
CONTROL AND COMPRESSOR
ACCESS PANEL
5 5/8'
143 MM
9 5/8'
244 MM
CONTROL AND COMPRESSOR
ACCESS PANEL
(3 - 5Tons)
TOP PANEL
4 1/4
108MM.
59/18'
141 MM
7 5/8'
194 MM
44 1/4'
1124 MM
TOP PANEL
4 1/4
108MM.
5 9/18'
141 MM
75/8'
194 MM
441/4'
1124 MM
TRANS
CONDENSER FAN
32 /4'
819 MM
CONDENSER COIL
UNIT CONTROL WIRE
7/8' (22MM) DIA HOLE
SERVICE GAUGE PORT ACCESS
1 3/8' (35MM) DIA. HOLE
UNIT POWER WIRE
1 3/32' (28MM) DIA. HOLE
CONDENSER FAN
38 /4'
921 MM
CONDENSER COIL
UNIT CONTROL WIRE
7/8' (22MM) DIA HOLE
SERVICE GAUGE PORT ACCESS
132' (35MM) DIA HOLE
UNIT POWER WIRE
1 3/32' (28MM) DIA HOLE
71
._... �..: .- .wwn- .1.:a^ti:WMi��M•rn.[rv�sxi�
All dimensions are in inches.
3 -5Tons — DownflowAirflow Supply and Return;
Through the Base Utilities
72
3 -5Tons — Horizontal Airflow Supply and
Return
3 -5Tons — Unit Clearance and Roof Opening
Dimensional
Data
24'
610MM
356M
RETURN
79/16'
80 MM— 6971MM
TSU CONDEN' ATE
CLEARANCE 37' (940 MM) '' \
CLEARANCE 48' (1219 MM)
(3- 5Tons)
THROUGH THE
BASE GAS
314 - 14 NPT CONDENSATE DRAIN
279116•
701 MM
THROUGH
THE BASE
ELECTRICAL
TYPICAL ROOF OPENING
4 7/6'
,1 129 M M
253 MM
2 1 91 6 6 1 1
6 12'
311/16' 165MM
94 MM
CLEARANCE
4 pik HORIZONTAL (914 4 M 457 MM)
44 1/2'
(1130 MM)
�
CLEARANCE 36' (914 MM)
RT-PRC006 -EN
All dimensions are in inches /millimeters.
3- 5 Tons — Roof Curb
14'
358 MM
3-5 Tons — Downflow Duct Connections —
Field Fabricated
Dimensional
Data
14'
356 MM
37 7/18'
951 MM
65 3/4'
1870 MM
24 3/8"
(619 MM)
14 1/16'
-(357 MM)
1 3/4'
45 MM
(3- 5Tons)
6 3/8'
213 MM
65 3/16'
61 3/4' 1656 M
1568 MM
18 3/4'
425 M
40314'
1034 MM
41 7/18'
1052 MM
16 3/16'
/ (411 MM)
TRANS
181/16'
(459 MM)
ALL FLANGES 1 1/4' (32 MM)
RT PRC006•EN 73
Table W1— Maximum UnitAnd Corner Weights (Lbs) And Center Of Gravity Dimensions (In.)
Unit Maximum Weights (Lbs)= Corner Weights (Lbs)1
Tons Model No. Shipping Net A B C
3
4
YSCO36A
YHCO36A
YSC048A
YHC048A
YSC060A
YHC060A
YSC072A3 *H
YHC072A3 *H
YSC090A3 *H
7 YSC092A3 *H
YHC092A3 *H
YSC102A3 *H
YHC102A3 *H
YSC120A3 *H
YHC120A3 *H
6
8' /s
10
NOTE:
1. Corner weights are given for information only.
2. Weights are approximate.
RTPRC006•EN
Weights
534 480
551 497
559 505
593 539
576 622
628 574
822 735
859 772
907 820
909 822
1010 923
986 899
1044 957
1074 987
1147 1060
CENTER OF
GRAVITY
WIDTH
D
CENTER OF GRAVITY
151
158
169
166
169
179
249
249
273
277
308
297
310
325
342
CENTER OF GRAVITY
♦- LENGTH
Novar Control
124
128
130
133
134
140
193
198
208
222
243
243
252
265
277
96
101
108
114
105
119
132
141
148
147
165
165
175
183
197
109
110
109
126
114
136
161
184
193
175
210
194
220
213
245
Accessory
Economizer
Barometric Relief
Powered Exhaust
Motorized Outside Air Damper
Manual Outside Air Damper
Roof Curb
Oversized Motor
Belt Drive Motor
Smoke Detector, Return
Smoke Detector, Supply
Coil Guards
Hinged Doors
Powered Convenience Outlet
Through the Base Electrical
Through the Base Gas
Unit Mounted Circuit Breaker
Unit Mounted Disconnect
MANE°
D Length Width
Table W2 — Factory - Installed Options Net Weights (Lbs )L
3-5 Tons
28
7
20
16
70
5
31
7
5
12
10
38
8
5
5
5
8
NOTES:
1.Weights for options not listed are >5 lbs.
2.Net weight should be added to unit weight when ordering
factory-Installed accessories.
Center of Gravity (In.)
Net Weight
32 19
32 19
33 19
32 20
32 18
32 20
39 21
39 22
38 22
40 21
39 22
40 21
40 22
40 21
40 22
6- 10Tons
36
10
80
30
26
115
8
7
5
20
12
38
13
5
.6
5
8
79
TRANE®
GE o\• w tie.
113 LC P0A6ove,r
i v,,\c o \q, W 9815$
FILE COPY .�
Packaged Gas/Electtic
Rooftop Units
PrecedentTM
3 - 10Tons — 60 Him O � Uv 1L
DEC 0 6 7.0(12 NOS 2 7
W:, t;•0 i � .0 200?
n ERtiti T c .
October 2001
RT- PR0006 -EN
ii7P2z3
..,.. ..... ...........n�nsu c - ,Sn'.vr :. rw,w.?{hn L,r;. S,S.S•:e wx�v�;. .tNR .ni�n;ix. �t.(r.a,
Table GD-1 - General Data
Cooling Performance'
Gross Cooling Capacity
SEER
Nominal CFM /ARI Rated CFM
ARI Net Cooling Capacity
System Power (KW)
Heating Perfommance'
Heating Models
Heating Input (Btu)
Heating Output (Btu)
AFUE %°
Steady State Efficiency ( %)
No. Burners
No. Stages
Gas Connection Pipe Size (in.)
Compressor
No./Type
Outdoor Sound Rating (dB)°
Outdoor Coil -Type
Tube Size (in.) OD
Face Area (sq ft)
Rows/FPI
indoor Coil -Type
Tube Size (in.)
Face Area (sq ft)
Rows/FPI
Refrigerant Control
Drain Connection NoiSize (in.)
Outdoor Fan -Type
No. Used/Diameter (in.)
Drive Type/No. Speeds
CFM
No. Motors/HP
Motor RPM
Direct Drive Indoor Fan -Type
No. Used/Diameter (in.)
DriveType/No. Speeds
No. Motors •
Motor HP (Standard/Oversized)
Motor RPM (Standard/Oversized)
Motor Frame Size (Standard/Oversized)
Belt Drive Indoor Fan -Type
No. Used/Diameter (In.)
DriveType/No. Speeds
No. Motors
Motor HP (Standard/Oversized)
Motor RPM (Standard/Oversized)
Motor Frame Size (Standard/Oversized)
Filters -Type
Furnished?
(No.) Size Recommended
Refrigerant Charge (Lbs of R -22)
12
(3 - 4Tons)
General Data Standard Efficiency
3-Ton Convertible Units
YSCO36A1 YSCO36A3, A4, AW
37,400
10.5
1,200/1,200
36,000
3.91
Low Medium High
60,000 80,000 120,000
47,000 63,000 95,000
80 80 80 81
80 80 80 81
2 2 3 2
1 1 1 1
1/2 1/2 1/2 1/2
1 /Climatuff® Hermetic
84
Lanced
0.3125
7.19
2/17
Lanced
0.3125
5.67
2/16
Short Orifice
1 PA NPT
Propeller
1/22
Direct/i
2,550
1/0.20
1,075
FC Centrifugal
1/10 x 10
Direct/2
1
0.33/0.50
950/1,101°
48/48
Throwaway
Yes
(2) 20 x 25 x 1°
3.8
37,400
10.7
1,200/1,200
36,000
3.79
Low Medium High
60,000 80,000 120,000
48,000 64,000 96,000
81 81
81 81
2 3
1 1
1/2 1/2
1 /Climatuff Hermetic
84
Lanced
0.3125
7.19
2/17
Lanced
0.3125
5.67
2/16
Short Orifice
1PA NPT
Propeller
1/22
Direct/1
2,550
1/0.20
1,075
FC Centrifugal
1/10 x 10
Direct/2
1
0.33/0.50
930/1,100°
48/48
FC Centrifugal
1/11 x 11
BeltNariabie Sheave
1
1.00/ -
1,750/ -
56/-
Throwaway
Yes
(2) 20 x 25 x 1°
3.8
4-Ton Convertible Units
YSC048A1 YSC048A3, A4, AW
50,300
10.0
1,600/1,600
48,000
5.28
1 /Climatuff Scroll
83
Lanced
0.3125
6.17
2/17
Lanced
0.3125
6.68
3/16
Short Orifice
1/3/4 NPT
Propeller
1/22
Direct/1
2,850
1/0.33
1,075
FC Centrifugal
1/11 x 11
Direct/2
1
0.60 /0.80
1,000/1,100
48/48
Throwaway
Yes
(2) 20 x 25 x 1°
4.4
49,200
10.0
1,600/1,600
47,000
5.40
Low Medium High Low Medium High
60,000 80,000 120,000 60,000 80,000 120,000
47,000 63,000 95,000 48,000 64,000 96,000
80 80 80 81 81 81
80 80 80 81 81 81
2 2 3 2 2 3
1 1 1 1 1 1
1/2 1/2 1/2 1/2 1/2 1/2
1/Climatuff Scroll
83
Lanced
0.3125
9.59
1/17
Lanced
.3125
6.17
3/16
Short Orifice
1 /°/i NPT
Propeller
1/22
Directt
3,610
1/0.33
1,075
FC Centrifugal
1/11 x 11
Direct/2
1
0.60 /0.80
1,000/1,100
48/48
1/11 x 11
1
1.00/ -
1,750/ -
56/-
Throwaway
Yes
(2)20x25x1°
3.8
NOTES;
1. Cooling Performance Is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not Include the effect of Ian motor heat. ARI capacity Is net and
includes the effect of fan motor heat. Units are suitable for operation to t20% of nominal cfm. Units are certified in accordance with the Unitary Air- Conditioner Equipment certification
program, which is based on ARI Standard 210/240.
2. EER and /or SEER are rated at ARI conditions and in accordance with DOE test procedures.
3. Integrated Part Load Value Is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80° F ambient, 80° F entering dry bulb, and 67° F entering wet bulb at ARI rated
cfm.
4. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards.
Ratings shown are for elevations up to 2000 feet, For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
5. AFUE Is rated In accordance with DOE test procedures.
6. Outdoor Sound Rating shown Is tested in accordance with ARI Standard 270. For additional information refer to Table PD -85.
7. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
8. 20 x 25 filter on medium and low heat models. 20 x 30 filter on high heat models
9. Motor RPM shown Is low speed. High speed RPM Is 1,060/1,145.
RT- PRC006 -EN
All dimensions are in inches /millimeters.
3, 4, and 5 Ton Standard Efficiency — Low and Medium Heat
3 and 4Ton High Efficiency — Low and Medium Heat
3, 4, and 5 Ton Standard Efficiency —High Heat
3 and 4Ton High Efficiency — High Heat
5Ton — High Efl4dency — Low, Medium, and High Heat
RT-PRC006 -EN
EVAPORATOR SECTION
ACCESS PANEL
ALTERNATE CONDENSATE DRAIN
CONNECTION 3/4.14 NPT DIA. HOLE
EVAPORATOR SECTION
ACCESS PANEL
ALTERNATE CONDENSATE DRAIN
CONNECTION 3/4.14 NPT DIA. HOLE
Dimensional
Data
41/4'
106 MM
23 9/16'
598 MM
69 7/8 421/4'
1749 MM 1073 MM
I/O NPT OAS CONNECTION
41/4'
108 MM
23 W16'
698 MM
89 7/8 421/4'
1749 MM 1073 MM
1/2 NPT GAS CONNECTION
5 6/8'
143 MM
9 5/8'
244 MM
CONTROL AND COMPRESSOR
ACCESS PANEL
6 5/B•
143 MM
85/8'
244 MM
CONTROL AND COMPRESSOR
ACCESS PANEL
(3 - 5Tons)
TOP PANEL
4 1/4
108MM.
41/4
5 9/15'
141 MM
75/B'
194MM
44 1/4'
1124 MM
TOP PANEL
108MM.
5 W16'
141 MM
7 5/8'
194 MM
441/4'
1124 MM
TRANE
CONDENSER FAN
32 /4'
819 MM
CONDENSER FAN
CONDENSER COIL
UNIT CONTROL WIRE
7/8' (22MM) DIA HOLE
SERVICE GAUGE PORT ACCESS
1 3/8' (35MM) DIA. HOLE
UNIT POWER WIRE
1 3/32' (28MM) DIA. HOLE
36 /4'
921 MM
CONDENSER COIL
UNIT CONTROL WIRE
7/S' (22MM) DIA HOLE
SERVICE GAUGE PORT ACCESS
1 3/8' (35MM) DIA. HOLE
UNIT POWER WIRE
1 3/32' (28MM) DIA. HOLE
71
All dimensions are in inches.
3 -5Tons — DownflowAir low Supply and Return;
Through the Base Utilities
3 -5Tons — Horizontal Airflow Supply and
Retum
3 -5Tons — Unit Clearance and Roof Opening
72
Dimensional
Data
24
MOW
100 MM
39/16
90 MM
CLEARANCE 48 (1218 MM)
THU CONDEN1 ATE
2 32
6 97 1 MM '
CLEARANCE 371 (040 MM)
(3 - 5Tons)
49/16'
110 1.4M
t
THROUGH THE
BASE GAS
3/4.14 NPT CONDENSATE DRAIN
27 9/16
701 MM
/ /
1
c:J. vavai�l:.,n....�n...�.�i sl'1]:w1.�i.. .a'�f✓ih.ai.. .. .a.airi - "1iaY:..e•a.. •. •tw
THROUGH 51/16'
E BASE
ELECTRICAL 125 MN
,._915/16•_
253 MM
CLEARANCE
HORIZONTAL FLOW . 18' (457 MM)
DOWNFLOW 36' (914 MM)
TYPICAL ROOF OPENING
° u 1 t
12
31111W 185
w MM
}
37 � \
(940 MM) /
4412'
CLEARANCE 36• (914 MM)
RT-PRC006 -EN
All dimensions are in inches /millimeters.
3- 5Tons— Roof Curb
3-5 Tons — Downflow Duct Connections —
Fieid Fabricated
RT PRC006•EN
14'
356 MM
Dimensional
Data
14•
356 MM
37 7/16'
951 MM
65 3/4'
1670 MM
,1._.141/16'
(357 MM)
24 3/8'
(619 MM)
1 3/4'
45 MM
/ 163/16'
(411 MM)
(3 - 5Tons)
MANE'
85 3118`
61 3/4' 1856 M
1568 MM
163/4'
425 M
40 3/4'
1034 MM
41 7/16'
1052 MM
181/16'
(459 MM)
ALL FLANGES 1 114' (32 MM)
73
NOTE:
1. Corner weights are given for information only.
2. Weights are approximate.
RTPRC006 -EN
Weights
Table W! — Maximum UnitAnd Corner Weights (Lbs)And Center Of Gravity Dimensions (In.)
CENTER OF GRAVITY
-4-- LENGTH —�
CENTER OF
GRAVITY
WIDTH
D
CENTER OF GRAVITY
Accessory
Economizer
Barometric Relief
Powered Exhaust
Motorized Outside Air Damper
Manual Outside Air Damper
Roof Curb
Oversized Motor
Belt Drive Motor
Smoke Detector, Return
Smoke Detector, Supply
Coil Guards
Hinged Doors
Powered Convenience Outlet
Through the Base Electrical
Through the Base Gas
Unit Mounted Circuit Breaker
Unit Mounted Disconnect
Novar Control
NOTES:
1.Weights for options not listed are >5 lbs.
2.Net weight should be added to unit weight when ordering
factory- Installed accessories.
TRANE.
Unit Maximum Weights (Lbs) Corner Weights (Lbs)1 Center of Gravity (In.)
Tons Model No. Shipping Net A B C D Length Width
/
3 YSCO36A 534 480 151 124 96 109 32 19
YHCO36A 551 497 158 128 101 110 32 19
4 YSC048A 559 505 159 130 108 109 33 19
YHC048A 593 539 166 133 114 126 32 20
6 YSC060A 576 522 169 134 105 114 32 18
YHC060A 628 574 179 140 119 136 32 20
6 YSC072A3 *H 822 735 249 193 132 161 39 21
YHC072A3 *H 859 772 249 198 141 184 39 22
YSC090A3 *H 907 820 273 208 146 193 38 22
7yz YSC092A3 *H 909 822 277 222 147 175 40 21
YHC092A3•H 1010 923 306 243 165 210 39 22
8% YSC102A3•1-1 986 899 297 243 165 194 40 21
YHC102A3 *H 1044 957 310 252 175 220 40 22
10 YSC120A3 *H 1074 987 325 265 183 213 40 21
YHC120A3 *H 1147 1060 342 277 197 245 40 22
Table W2 — Factory Options Net Weights (Lbs)'•
Net Weight
3 -5Tons 6- 10Tons
26 36
7 10
80
20 30
16 26
70 115
5 8
31 —
7 7
5 5
12 20
10 12
38 38
8 13
5 5
5 .5
6 6
8 8
79
�.«.. ,,....,....w,ea,.xwm-
i
F625 -052 -000 (S/97)
COMFORT' MECHANICAL INC
6617 SO 193RD PL #P -105
KENT WA 98032
DEPARTMENT OF LABOR AND INDUSTRIES
REGISTERED AS PROVIDED BY LAW AS
CONST . CONT. SPECIALTY
•:.G i , i,REGZSTh5# I !EXP.- DATE
;CCAACG.;COMFOMI015LA- :06 /01/2004
'EFFECTIVE 'DATE 06/01/1999
re 2
N�W
W �
1 1.
V 0 .
O 1-
W W
ni
D.
—
0 1-
z
Y•:{d'.•.Y v : •::::::::::::: ::::: v:: v::: •: v: ::: ....::: v v,•:
vv.:..Y ....{
v •• {v,. ; .v •.{vv.. [ � • 4 • }:.Y k .C } . :..v. : $ Y s 4iFY..:: x.
�;}:YV.{•.:• •h " \ �{ {Yl •Y{. {p: {.;,v{14::
:. :a'Y.oR
.h }{.: r..,,.....,0..•. ....:}:• Y:,`••::] C i.:,'• YY:{•' r:•:::{. Y:v �:{.. v,• . ::.......:.,•::
. {:,v: v'.; •:.•.::.v:
.:.!•{ • : v }::
• r v:: �{v{. { :
v .; {•Y {{.:4:
•• , !.•y:•••:Y:f.:: ",:
{} ti•Y ?:
. . { i�}i `
•.
{tiv: :.Y:.i:•; �:�•{: i`•'{ +•Y4F: +.4:'•+'v'
....n.
i { }F'ry}O''
..:...::...:. �:{ {•::•Y:•Y:•:3: { {.
:: . .
{.....:... :.:.:......
ti s - a •sf -/8 v
Balance Due: $
G 3.1o 3
Need Current Contractor Registration Card:
1s ❑ No
eed to Enter Contractor Information in Sierra: ❑ Yes TSIo
VD
Z
W
re J U
00
y
J =
WO
II
ON
O ~
W W
F-
u_ O
U • �
OF-
z