Loading...
HomeMy WebLinkAboutPermit M02-236 - BOEING #13-01BOEING #13 -07 BLDG 70002 EAST MARGINAL WAY SOUTH EXPIRED 3-14-04 M02 -236 • a.Vei4, 4154;4014.0.,,,; 44,0,'.'U'i Signature: Print Name: doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0003400021 Permit Number: MO2 -236 Address: 10002 EAST MARGINAL WY S TUKW Issue Date: 09/15/2003 Suite No: Permit Expires On: 03/13/2004 Tenant: Name: BOEING #13 -01 Address: 10002 EAST MARGINAL WY S, SEATTLE WA Owner: Name: THE BOEING COMPA Phone: Address: PO BOX 3703 M/S #1F- Contact Person: Name: RICK FORD 414 Phon Phone: 206/854 -1881 Address: BOEING CO, PO BOX 3707 M/S 4t1 '8/ `/ �Q Contractor: Name: BOEING COMPANY Phone: Address: PO BOX 3707, M/S IF -09, SEATTLE, WA Contractor License No: BOEINC *294ML Expiration Date:01 /14/2005 DESCRIPTION OF WORK: REPLACE ROOFTOP CHILLER, CHILLED WATER PUMPS WITH MORE EFFICIENT UNITS Value of Construction: $25,000.00 Type of Fire Protection: Permit Center Authorized Signature: Date: /S - d3 I hereby certify that I have read and examine this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The grantin : of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatin stru ;•n qr the performance of work. I am authorized to sign and obtain this mechanical permit. polepec4 MECHANICAL PERMIT Fees Collected: $59.81 Uniform Mechnical Code Edition: 1997 C "pc Rem awe( Date: L�isl • ?3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. MO2 -236 Printed: 09 -15 -2003 a«.;.•:h'.m +,:t.'�: Y >::::f�ti:.n:<::w'..n`.;: fir:;: �J.:: ah' v�e.�`.���s -ct. Parcel No.: 0003400021 Address: 10002 EAST MARGINAL WY S TUKW Suite No: Tenant: BOEING #13 - 01 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296 - 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Readily accessible access to roof mounted equipment is required. 7: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating c. , truction or the performance of work. Signature: Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS 7 RaihV £vf''Gf&i Date: \AL, i MO2 -236 Permit Number: MO2 -236 Status: ISSUED Applied Date: 12/04/2002 Issue Date: 09/15/2003 Printed: 09 -15 -2003 Project Name/Tenant: X e f 4 e AA/vs 04/ /3 -O / Value of Mechanical Equipment: "Z-S, ooD e Site Address vppp2, - e. r Y l Mt-6//v », . Al) # ( S o City State/Zip: Tax Parcel Number: ODD -34.0/ Property Owner,. .0 )9 6 p . Address: Phone: ( ) Street O. . x 3707 , /f 16 -$g � T7G City State/Zip: Fax #: ( ) Contractor: S Liz-:" Phone: ( ) Street Address: /4oEill Z. Z-4 4 .zt 6- City State/Zip: Fax #: ( ) Contact /) L t-o e17 Phone: (2 04 854 - I $� Street Address: Sr4, City State/Zip: Fax #: ( ) `BUILDING,O OR:AUTHORIZED AGENT : :' . Signature: J /J e2 / / j Date: /Z _ 4_ _ Print name: / Q / 1-4- 1--e Phone: ( Z01G 5 4- t � 8 1 Fax #: ( ) Address: City /State/Zip: CITY OF T - 'KWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Number: Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL" PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specific): Cio /t O OFTv.> LyH /L L6e , e'f /4 L. cv eo P ,s1p oAe /E A/ 7 dAe/ Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT ! HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: Date Date application expires: to -q Application taken by: (initials) 09/10/2002 ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C, over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment (including commercial kitchen hoods) weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. :;�'. 't' ' '► f'''A 49 Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Heat loss calculations or Form H -6. Equipment specifications. 09/10/1002 miscpmt.doc Submittal Requirements New Single Family Residence Change -out or replacement of existing mechanical equipment Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace I Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition.. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Payee: BOEING TRUST ACCT 000.386.908.03 Payment Other MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Parcel No.: 0003400021 Permit Number: MO2 -236 Address: 10002 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 12/04/2002 Applicant: BOEING #13 -01 Issue Date: Receipt No.: R03 -01125 Payment Amount: 59.81 Initials: SKS Payment Date: 09/15/2003 10:32 AM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount 59.81 Account Code Current Pmts 000/322.100 47.85 000/345.830 11.96 Total: 59.81 '691 09/16 9710 TOTAL 0.00 Printed: 09 -15 -2003 February 3, 2004 Rick Ford P.O. Box 3707, M/S 46 -88 Seattle, WA 98124 RE: Permit Application No. MO2 -236 10002 East Marginal Way South Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to March 13, 2004, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania �Kencer Permit Technician City of Tukwila Xc: Permit File No. MO2 -236 Bob Benedicto, Building Official Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 z 0O to o W U W. W LL ? CA d 1- 0 Z H W uj p 0 ON 0 I— W W H- L' 0 W Z 0 O Z ACTIVITY NUMBER: MO2 -236 PROJECT NAME: Boeing 13 -01 SITE ADDRESS: 1000 E Marginal Wy S DATE: 12 -04 -02 /\ Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: it r G r'� Building ivision Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete rz Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Documents/routing slip.doc 2-28-02 PERMIT COORD COP\ PLAN REVIEW /ROUTING SLIP ,Z Fire rrevention Structural Incomplete ri Structural Review Required Planning Division ❑ Permit Coordinator DUE DATE: 12-05-02 Not Applicable ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 1 -02 -03 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY • S y Mai CHILLER 011110Pl aL PROMO INSTALL SUMMON FM & SPOT COOLER w +r...-, - t.•. ..fir. : ti * •.. VICINITY MAP PROJECT SITE I 99 oa DEVELOPMENTAL CENTER 110428 -00 7,4155 -00 #525.1lb -o0 I 9.15.02 EOEI STALL B FROM KENT & AUBURN U G VAY FHC LDI\C C MILITARY FLIGHT CENTER 10,000 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 AREA MAP OXBOW PARKING LOT • PROJECT SITE NO SCALE 13 -01 BUILDING LOCATION • ifiLdirOE //YO• GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO RICK FORD COL N /1, AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT CHECKLIST CHECK BOX O THESE DRAWINGS CONFORM TO THE 1994 U.B.C., U.F.C., U.P.C., AND THE 1990 BARRIER FREE CODE AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPUANCE WITH CITY OF TUKWILA ZONING. O O ENGINEERING CALCULATIONS ( IF APPLICABLE ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10 -A. ra BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: O 1. GENERAL PERMIT (SHELL & CORE) 6 SETS OF ENERGY CALCULATIONS 2 SETS OF CIVIL DRAWINGS WITH UTILITIES 2 SETS SOILS REPORTS, STAMPED BY GEOTECHNICAL ENGINEER 2 SETS STRUCTUR$L CALCULATIONS 2 SETS PROJECT CONSTRUCTION SPECIFICATIONS 2 SETS TOPOGRAPHICAL SURVEY 2 COPIES OF LEGAL DESCRIPTION 2 SETS OF WORKING DRAWINGS O 2. TENANT IMPROVEMENTS, 4 COMPLETE SETS ► 3. MECHANICAL, 2 COMPLETE SETS O 4. FIRE PROTECTION /SPRINKLERS, 2 COMPLETE SETS El BRIEF PROJECT NARRATIVE J1525396 -00 WILL REPLACE AN EXISTING ROOFTOP CHILLER AND CHILLED WATER PUMPS. • ACCEPTABILITY DOS DESIGN SPECIFICATION 6�APPIIOYEp OPPNVIED WV J DEPT. • T CF \TER 525396- ONE WNW ] 11 «• a I Vtittla DU RTE 10 -11 -9e No. MECHANICAL MASTER MO TITLE SHEET - DRAWING INDEX C MI EQUIPMENT INDEX B RFM61 ROOF HVAC - PLAN VIEW E RFM50'1 CHILLER SECTIONS & DETAILS B RFM502 CHILLED WATER PIPING DETAILS LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS FIRST FLOOR SECOND FLOOR BOILER ROOM BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL [ELECTRICAL IV PLUMBING ij GAS 'PIPING CITY OF TUKWILA BUILDING DIVISION i!.^ rw.... . . �.w+►w . •1 w - • • «.. SHEET TITLE BUILDING 13 -01 TITLE SKEET — DRAWING INDEX DRAWING INDEX SHEET CODE SUMMARY IYIFC :. � ., . : I understand that anprovl,s r subioct tV c urr ";(� C��!�t�iilC,r' ? - v.J ar of plans dotes not a � +��, .� ,� , the , ;.,,!:2 1 ,0r1 of any adotted couo r c' -' CC pt c f con- • l..h �r�: 1��.(.'' f(�,'(•�„! � tractoes coE cf ai.prov�d plans ackrt:;wlcdged. By ?if "' = Dat .�.�.��.,. ►.% Permit No. I t j'4 P Cu."" . ._ 1. . h MAD TO �`J PP ` 1 r , ► r r .. SHEET TTI'LE EXPIRED OM NO. ' M O CITY Of TUKWILA APPROVED DEC 18 2002 w r L rli►j{,'' 17% -Ant A cuiem"nsewismax 13 -01 —MO TUKWILA 1994 UBC, WASHINGTON STATE ENERGY CODE. WASHINGTON STATE BARRIER FREE CODE AND ADDITIONS PER CITY OF 1UKNIU■ GROUPS B OFFICE & FACTORY F 011ASION 2 TYPE q, NON-COMBUSTIBLE-(OFFICE); & TYPE IN (FACTORY) SEPARATION 60 FEET (MIPIMUM ALL SIDES) 49,150 7,500 - OFFICE + 22,870 SHOP 7,500 - OFFICE + 4,900 S.WING OFFICES + 5010 STORAGE 1,370 29 FT. 2 STORIES ( +N. MEZZANINE) Iff (C-1 1007 OCCP OFFICE & 200SF OCCP MANUFAC1URING r 150 + 49 + 122 / /a ‘, BARRIER FREE 0 0 FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT 1 3 :O. NO. ND. 9.15.02 • ✓ I UNIT & BLOWER UNIT HEATERS MARK MARK QUANTITY BTU /HR MINIMUM CFM STD. AIR ENTERING AIR 'F LEAVING AIR F GPM ENTERING T F WATER LEAVING WATER 'F APPROX.. H.P. OUTLET NOZZLES REMARKS COWL . OUT. VEL. MAX. COWL . OUT. VEL. THROW OR SPEED MOUNTING HEIGHT DBH -1 7 200,000 2850 70' 137 12 1 /2 240 207 1 /2 2130 1820 55 19.5' COUNTER CLOCK TOP HORIZ. UH -1 5 168,000 6 ' 70' 132 10 1/2 240 206.5 211 1/6 1/6 , 1/2" 1150 12.0` 18.5 HORIZONTAL VERTICAL w UH -2 UH -3 UH-4 2 2 1 124,000 159,000 189,000 _ 2540 2220 2540 2780 70' 70' 70' 123 129 134 9 8 9 1/2 240 240 240 198.5 199 1 6 1/6 , , WASH FOUNTAIN 2" 12.0' 12.0' HORIZONTAL DO UH -5 1 104,750 1590 695 70 70' 132 122 5 1/2 2 240 240 200 195 1/12 1/30 1/2" _ 1" i 10.0' * DO DO UH -6 2 43,200 AIR--COOLED CHILLER (CH) SCHEDULE MARK CITY TONS MARK S C ) � ELECTRICAL VOLTS PH HOT WATER 61 'F 'F EVAPORATOR FT P F ACTO 8 "0 CONDENSER S 4" EER RE - QUANTITY GPM HP � a) CH1 NR COOLED- SCROLL COMPRESSOR 60 40 15 TON 25.2 178 460 ,3 60 30 -90 54 44 29 .0005 R -22 6 ' 1.0 9.3 TRANE ICGAEC604ADA1DHPRSW WITH LOW AMBIENT AIR DAMPER SUPPLY DIFFUSERS PLUMBING FIXTURE SCHEDULE NECK SIZE MARK REMARKS . FIXTURE WASTE VENT HOT WATER 61 COLD WATER 2ND FLR OFFICE REMARKS WC -1 8 "0 WATER CLOSET 4" 2" 8 'O 2ND FLR MEZZ. Shoemaker Series LSD 3 -slot, 4' wide, 3 slot, 200 CFM unless noted 1" - WALL HUNG UR FIRE STATION URINAL. 2" 2" ' 1" OIL HOUSE BLOWOUT L -1 1800 LAVATORY 1 1/2" 1 1/4" • 1/2" 1700 , 1/2" 1150 , SS , SERVICE SINK 3" 1 1/2" 1/2" , 1/2" WF -1 , , WASH FOUNTAIN 2" 1 1/2" 1" 1 54" SEMI CIRCULAR WF-2 WASH FOUNTAIN . 2" _ 1 1/2" _ 1" i 1" 56" SEMI - CIRCULAR D.F. DRINKING FOUNTAIN 1 1/4" 1 1/4* 1 " 1 /2 1 SHR. ` SHOWER 2" 1 1/2" 3/4" , 3/4" FD _ FLOOR DRAIN . SEE SPECS RO ROOF DRAIN _ _ SEE SPECS SUPPLY DIFFUSERS QUANTITY NECK SIZE LOCATION REMARKS . 54 8 "0 1ST FLR OFFICE Shoemaker Series 700 -MA -0 14 "x14" W /8" neck, 200 CFM unless noted 61 8 "¢ 2ND FLR OFFICE Shoemaker Series 700 -MA -0 14 "x14" W /8" neck, 200 CFM unless noted 28 8 "0 2ND FLR MEZZ. Shoemaker Series 700-MA-0 14 "x14" W /8" neck, 200 CFM unless noted 6 8 'O 2ND FLR MEZZ. Shoemaker Series LSD 3 -slot, 4' wide, 3 slot, 200 CFM unless noted 4750 - 3/4 E -3 FIRE STATION 470 1/2" _ 1500 _ CCW 1/8 _ BELT DRIVEN E -4 ... EXHAUST FANS MARK AREA SERVED CFM STD. MR SP INCHES H2O OUTLET VEL. MAX. ROTATION & DISCH APPROX. HP REMARKS E -1 •' FIRST FLOOR OFFICE 3352 3/4" 4750 - .73 PACE ICRE-27AF BELT DRIVEN E -2 SECOND FLR. OFFICE 2670 1/2" 4750 - 3/4 E -3 FIRE STATION 470 1/2" _ 1500 _ CCW 1/8 _ BELT DRIVEN E -4 OIL HOUSE 1500 1/4" 1800 CW 1/4 SPARK PROOF WHEEL E -5 FAN ROOM 1700 0 1150 - 1 /20 PUMPS MARK LOCATION SERVICE GPM HEAD FT. APPROX. HP P -1 BOILER ROOM HEATING 240' 266 38 P -2 DO HEATING STANDBY DO DO P -3 EQUIPMENT ROOM CHILLED WATER 90 30 P -4 DO CONDENSER WATER 110 45 P -5 DO RADIATION BOOSTER 16 14 P -6 : FIRE STATION HEATING BOOSTER 12 10 POWER ROOF VENTILATORS MARK QUANTITY AREA SERVED CFM APPROX. REMARKS PRV - 4 SHOP 27500 5 � • A S MARK AREA SERVED AH1 AH2 AH3 Ali 5 SC1 i OFFICE OFFICE OFFICE DEVELOPMENTAL MOWN 1ST FLOOR DATA ROOM Ontiew CFM S.P.# STD H2O MR 22,000 5.83 18,000 10,000 1 8" AH4 2ND FLR CONF. RM 2,500 3.35" MEZZ . OFFICE 22,000 3.00 AH6 f.zz. OFFICE 22,000 1.77" SPOT COOLER (SC) SCHEDULE MARK NUMBER LOCATION TYPE AIR - COOLED SPLIT UNIT 4110428-00 4525396-00 SUPPLY FAN OUTLET MOTOR VELOCITY POSITION MAX. 2,916 _ LEFT R. 2,386 RIGHT R. 1600 RIGHT FRT. CCW 2 2990 RIGHT FRT. 4 CFM 1600 CFH MBH TOTAL 56.0 ROTATION BRAKE CFM ENTERING LEAVING & H.P. AIR ' F _ AIR ' F DISCH CCW 27.07 2011,000 ih 80.0 63.0 55.2 53.6 44 52.4 CW 8.05 EVAPORATOR DATA MBH SENS. 43.2 ».19.01 EAT 'F 80 DB 66.7 WB 27.07 10.59 1 HP VENTILATION & AIR CONDITIONING UNITS FLA 3.1 CFM 2500 FAN HP 1.5 COOLING COIL AMBIENT 80 CHILLED WATER DB WB DB WB ENT ' F LVG ' F CCW 2.48 2,500 78.0 60.0 54.5 50.7 45.0 55.0 OUTDOOR CONDENSING UNIT ESP IN WG .5 irf FLA 19.0 • MAX . FACE VELOCITY GPM ' FPM 2076.6 508 13.8 500 VOLTS 480 ELECTRICAL PH 3 HZ 60 MIN. ROWS 6 CFM 22,000 10,000 2,500 ENTER LEAVING MR MR 'F 'F 55.0 104.2 20 70 45 98.2 FIRE TUBE HOT WATER GENERATORS, GAS FIRED, OUTPUT OF 2,010,000 BTU /HR WHEN HEATING APPROXIMATELY 101 GPM OF WATER FROM 200'F AT 30 P.S.I. MAXIMUM WORKING PRESSURE. HEATING COIL ENTER LEAVING WATER WATER 'F 'F 190.0 167.8 240 200 180 160 REMARKS HOT WATER GENERATORS L1dFff' • FACE GPM VELOCITY ROWS FPM REMARKS • • 108.3 560 2 MULTI -ZONE UNIT RETURN AIR FAN 28 • 700 2 VENTILATION UNIT VU- 13.8 2 GAYLORD #CSU -4K DURHAM -BUSH McQUAY UNITED COOIAIR YODEL f MVA4G -4BSS DATA ROOM AIR CONDITIONER, 4 TON DUAL CIRCUIT COOLNNG UNIT W /DISCH URGE PLENUM, FACTORY MOUNTED Ic WIRED CONDENSATE PUMP, DRAIN PAN OVERFLOW SNITCH AND SLOPED STAINLESS STEEL DRAIN PAN. OR APPROVED EQUAL UNITED COOIAIR MODEL #BAG4A OUTDOOR CONDENSING UNIT WI INTERNAL HOT GAS BYPASS, SUCTION LINE ACCUMULATOR AND QUENCH VALVE TO ALLOW FOR LONG REFRIGERANT UNE LENGTH TO MATCH INDOOR UNIT MOVE OR APPROVED EQUAL ACCEPTABILITY 11115 OE51p1 U 5/EC�RAl10N R ED APPNOVED OUR. OWE OMR eatemr PIPING SYMBOLS MECHANICfr& MASTER GIMP _ .. IMO MOO _ SS F ammuorrimmessommoimmisamaimismelmasemmiND COLD WATER (C.W.) HOT WATER (H,W,) HOT WATER RETURN (H.W.R.) SANITARY SEWER STORM SEWER FIRE & SPRINKLER MAINS VENT PIPING SOIL & WASTE PIPING ABOVE GROUND SOIL & WASTE PIPING BELOW GROUND KEY SHEET - EQUIPMENT INDEX BUILDING 13 -01 - • EXPIRED MAR 14 7004 vi peo lo I �' J fl t I. C "Y OF .; % ∎ L A DEC - 4 2002 p :L :,i CENTr. 1 mic M i 525396-00 lamp NO. / OW E • 13 -01 -M1 • CHILLED WATER PIPING SHALL BE SCH.40 BLACK STEEL. JOIN PIPE WI TH 1ACTAULIC PIPE COUPLINGS. INSULATE CHILLED WATER PIPE WITH 2" THICK MANVILLE MICROLOK OR APPROVED EQUAL. ALL INSULATED PIPING ON ROOF SHAD. HAVE AN ALUMINUM WEATHERPROOF JACKET. LABEL ALL PIPING AS TO CONTENTS AND FLOW DIRECTION. FILL CHILLED WATER SYSTEM WITH 400 GALLONS OF' ETHLEYNE GLYCOL FOR A 25X SOLUTION. I INSTALL CHILLER ON EXISTING STAND PER SKETCH K72UO21121. CONNECT CHILLER TO EXISTING 6" CHILLED WATER SYSTEM 6 "x4" REDUCERS. EZ::::» REPLACE EXISTING PACO PUMPS WITH BELL & GOSSETT 2-1/2x 2-1/2x9-1/2B PUMPS, REUSE EXISTING SHUTOFF VALVES, CHECK VALVES, CIRCUIT SETTERS AND STRAINER. SEE DETAIL (2 PLACES) RFM6 RFM502 • *I I • •,R • • I CHILLER SOME STRUCTURE NOT SHOWN FOR STRUCTURAL DETAILS SEE SK72MO21121 REF. 66X22 O.A.DUCT SECTION FOR STRUCTURAL DETAILS SEE SK72MO21121 REF. 66X22 OADUCT CHILLER REF. 301N.T.S.) ELEVATION SHOWING EXP. TANK & AIR SEPARATOR 30 "(N.T.S.) EXPANSION TANK AIR SEPARATOR . GIJ NEY 7.25.90 4.22.90 4.22.90 4.22.90 CHILLER SECTIONS it DETAILS DEV. CENTER, WA moos -ao B RFM501 525396-00 6.18.02 DETAIL SCALE: NONE ELEV SHOWING COIL DR & TRAP COIL DRAIN NECT COOUNG L COUNTERFLOW do WATER SCALE: NONE 30 "FOR 2 PIPES 54 "FOR 4 PIPES CHILLED WATER PIPING DIAGRAM CHILLED OR 1TYP 2" ( HOT WATER LINES INSTALL SUPPORTS AT 10FT INTERVALS NOTE: FOR 4 PIPE SUPPORT CANTILEVER 2 PIPES OUTSIDE OF SUPPORTS. PIPE SADDLE SUPERSTRUT NOTE: CONNECT HEATING COIL COUNTERFLOW AIR & WATER 15 "j WO DRAIN HOLE COPE FLANGE & BEND UP WEB HOT WATER PIPING DIAGRAM SCALE: NONE PIPE SUPPORTS PIPE HANGER D SCALE: NONE �p (��i & m5pi h" o U- -BOLTS LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES INSTALL CHILLER ON EXISTING PLATFORM PER CIVIL DWG 72MO21121. CONNECT EXISTING 6" SUPPLY AND RETURN PIPING TO NEW CHILLER WITH 6 "x4" REDUCERS. MAR 14 2004 Ote -4J PE-'r.'►T CPO 0 4 O 7 ; 2 • • 4 • • 1 • • • • • ;� BALANCING VALVE SCHEDULE 8ic SETTING TAG �� • SIZE FLOW 11116. r : — NOT USED PD PSI - 1.3 4" FL TANK FITTING; BELL & GOSSETT NO. AWL 4" FLANGED 170 (1) 1.3 WATER PRESSURE REDUCING VALVE, BELL & GOSSETT NO. FB3 SET AT 12 PSI, RELEIVE AT 30 PSI 4" FLANGED 80 (1) 1.5 e) 2" FLANGED NOT USED ' 1.0 es 1 e � 3" FL 90 (1) I 1.3 2 0 : • . D 1.5 3' FLANGED 206 1.5 ED 7 lh* FLANGED 45 0.8 3 1 ih" RANGED 45 0.8 NI./ 1 l FLANGED 25 0.3 4s 1 W RANGED 25 0.3 , EQUIPMENT LIST TAG NO DESCRIPTION e ► 120 GALLON CAPACITY TANK e9 TANK FITTING; BELL & GOSSETT NO. AWL (5 AIR SEPARATOR, BELL & GOSSETT NO. R L - 6 j WATER PRESSURE REDUCING VALVE, BELL & GOSSETT NO. FB3 SET AT 12 PSI, RELEIVE AT 30 PSI a v FL a • . NO. U- 909 -SQT, VIZ E 45 TRANE MODEL ICGAE6O4ADA1DHPRSW, AIR COOLED SCROLL COMPRESSOR CHILLER - 60 TON CAPACITY COOLS 30 -120 GPM FROM 54 F TO 44 F AT AMBIENT TEMPERATURE OF 95T. PRESSURE DROP THRU CHILLER IS 6 FT AT 90 GPM 460 VOLT, 3 PHASE • In 1111111118 Is111•15aw BLIND FLANGE '``.. 6 " PIPE SUPPORT SEE DETAIL L, RFM ' 2 R 501 V BUTTERFLY VALVE STRAINER BUTTERFLY VALVE STRAINER VIM MINI 4szs3N-oo 4 PUMP SUPPORT BAN_ PLAN VIEW SECTION VIEW SCALE: 1/2" = r-0" NOTE (1) SET VALVE WITH BOTH PUMPS P -10 & P -11 OPERATING & PUMPING WATER THRU BOTH CHILLERS. OAR 19611M �� 11.21.02 A RFM6�RFM (CHECK VALVE CHECK VALVE • HOSE CONNECTONS FOR MANUAL FILL M t""'"'" CW COLD WATER MAKE -UP 3/4" HOSE - DISCONNECT WHEN SYSTEM IS FULL BACK FLOW PREVENTER VALVE PRESSURE REDUCING VALVE ROOF I • Ii?§,„,AroxivArier CAPPED TANK FITTING El) AIR SEPARATOR ANTI - FREEZE FILL - 6 "LONG - 6 "0 PIPE W /CAP THERMOMETER 4 " a 3" TO AIR "'- HANDLER - 3" I a '^ W EXPANSION TANK (q) 3" 12 "MAXIMUM BLIND FLANGE CHILLED WATER PIPING DIAGRAM SCALE: NONE ACCEPTABILITY TIC 0131C• " " " SPECIFICNION 6 4 AP* atrr. OAR j. pMY • BLIND FLANGE TM& �STRIUNER W/ BLOW-OFF VALVE 4 ' .- -PUMPS 4 M ,, r BLIND RANGE 6 e f 6" '�`� CAPPED PETE'S PLUG BALANCING VALVE �TO AIR HANDLING 4 N 4 +�J UNIT BELOW 1 \ BUTTERFLY VALVE R 61 M '2 9. 90 7.25.90 5.16.90 6.22 90 6.22.90 TRLE r HLLED WATER PIPtIG DETALS BUILDING 13-01 MECHANICAL MASTER - DEV. CEMER, WA LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES REPLACE EXISTING PUMPS WITH BELL AND GOSSETT PUMPS USE EXISTING VALVES, CHECK VAVVES, CIRCUIT SETTERS AND STRAINERS. EZ:›- SET BALANCING VALVES TO GPM SHOWN. (3 PLACES) 1 • S k O N 4� " RIED MAR 14 2004 / 0402 3 "'"" I A RFM502 via 13 -01- RFM502 • CIT'! OF _rUK NiLA r ^ CEO -- 4 2r�0 p �,��Y11T lit' 1 7 r � '.10111 MD. i Fit 4525396 -00 11.22.02 I ' P - t IP .`...,. TAG i GPM HEAD FT. H.P. RPM VOLTS PHASE PUMP MODEL 1 6 160 50 5 1750 460 3 BELL & GOSSETT SERIES 80 2-1/2x2-1/2x9-1/2B 4 E5), 160 50 . 5 I 1750 460 3 BELL & GOSSETT SERIES 80 2-1/2x2-1/2x9-1/2B ink ;j 5 45 2 1750 4.0 3 PAC 4 IN ' -1 0 -7 e\ 15 - 1/4 1750 120 1 - PACO, INUNE, VL- 1250 -5 • In 1111111118 Is111•15aw BLIND FLANGE '``.. 6 " PIPE SUPPORT SEE DETAIL L, RFM ' 2 R 501 V BUTTERFLY VALVE STRAINER BUTTERFLY VALVE STRAINER VIM MINI 4szs3N-oo 4 PUMP SUPPORT BAN_ PLAN VIEW SECTION VIEW SCALE: 1/2" = r-0" NOTE (1) SET VALVE WITH BOTH PUMPS P -10 & P -11 OPERATING & PUMPING WATER THRU BOTH CHILLERS. OAR 19611M �� 11.21.02 A RFM6�RFM (CHECK VALVE CHECK VALVE • HOSE CONNECTONS FOR MANUAL FILL M t""'"'" CW COLD WATER MAKE -UP 3/4" HOSE - DISCONNECT WHEN SYSTEM IS FULL BACK FLOW PREVENTER VALVE PRESSURE REDUCING VALVE ROOF I • Ii?§,„,AroxivArier CAPPED TANK FITTING El) AIR SEPARATOR ANTI - FREEZE FILL - 6 "LONG - 6 "0 PIPE W /CAP THERMOMETER 4 " a 3" TO AIR "'- HANDLER - 3" I a '^ W EXPANSION TANK (q) 3" 12 "MAXIMUM BLIND FLANGE CHILLED WATER PIPING DIAGRAM SCALE: NONE ACCEPTABILITY TIC 0131C• " " " SPECIFICNION 6 4 AP* atrr. OAR j. pMY • BLIND FLANGE TM& �STRIUNER W/ BLOW-OFF VALVE 4 ' .- -PUMPS 4 M ,, r BLIND RANGE 6 e f 6" '�`� CAPPED PETE'S PLUG BALANCING VALVE �TO AIR HANDLING 4 N 4 +�J UNIT BELOW 1 \ BUTTERFLY VALVE R 61 M '2 9. 90 7.25.90 5.16.90 6.22 90 6.22.90 TRLE r HLLED WATER PIPtIG DETALS BUILDING 13-01 MECHANICAL MASTER - DEV. CEMER, WA LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES REPLACE EXISTING PUMPS WITH BELL AND GOSSETT PUMPS USE EXISTING VALVES, CHECK VAVVES, CIRCUIT SETTERS AND STRAINERS. EZ:›- SET BALANCING VALVES TO GPM SHOWN. (3 PLACES) 1 • S k O N 4� " RIED MAR 14 2004 / 0402 3 "'"" I A RFM502 via 13 -01- RFM502 • CIT'! OF _rUK NiLA r ^ CEO -- 4 2r�0 p �,��Y11T lit' 1 7 r � '.10111 MD. i Fit 4525396 -00 11.22.02 • 3 "C, 3 -500 MCM HUGHES INSTANT HOT WATER HEATER 277V, 9KW HUPHEi 13 /0 HUGHES START /STOP S -1 FAN ON PLAMAN ' 20 it MCC #1 83,66 200 AMP CIRCUIT BKR INTERLOCKED W/ RECEPTACLE I MIII— II I I I Nor mu rum 147018 -00 MCC #1/cs w — II IU —I I el 111171;111 eSLle@ t /2' - 3110 DRAW THRU AIR SYSTEM EXHAUST FAN (ROOF) TART /STOP _ PNL C10 2 " -4#1 /0 e TO P 75 K 120/ PLAN 1 /8" : 1 PANEL Al2 277[480V, 30, 4W 400HZ- 125 KVA MG SET LEGEND: 0 110 YOIT 011.3 -�, 4-POLL CROIISE ■ IBS ME AFR, XX APNEIiES. IIO you SEET.. 3-I11IE. hPOLE. MOUSE HINDS, 1XE AR. )0C AMPERES. 41o77V p51IVII11ON Phe. m TRANSFORMER, CAPAp1Y. PHASE ! 11OLTME AS SilOwl t 410V 3 PHASE MOTOR MOTOR STARTER, MAGNETIC r MOTOR STMNR YAgE11C W/ DISCONNECT Sw101 ■ Y01011 STMIEII, MANUAL I MO 019001INECT SwCM. NON-FUSED, XX AMPERES fj) warE/EauIP+Ewt RUINER x, Y i+oRSEMpt (SEE tESOD FOR =MIT SCHEDULE) GgNERAL NOTES; 1.) ALL CONDUIT TO BE 1/2' EMT UNLESS OHMS( NOTED. 2) AIL VIRE TO BE #12 11111 IHWI UNLESS OT ERUSE NOTED. 3.) THE MOM COLOR COOMrG OF CONDUCTORS SHILL 11 MER1 D ON ALL C IRCI ITS 600 WILTS OR LESS 120/SOdv 277/400V ® Remove abandoned motor starter on roof. and conduit/wire bock to source. N in operation contact Engineer. �► Disconnect (2) 7hp motor pumps, revise motor overloads and energize (2) new 5 hp pumps. Use »ii* type wire. Wire to CMCS for auto controls. ri >" Remove we and conduit to chiller, loud side of outdoor fused dieconnect on roof. replace (3)fuses with 125 amp FRS - 8--125 fuses and new wire and conduit. PHASE LEF BUS IN PANEL) BLACK BRO I 'V PHASE lTER BUS 11 PMEL) RED ORMIGE • C" PHASE BUS It PM1EL) BUR MOW NEUTRAL MN GRAY E,ICNT CROWD GREEN LARGE SIZE C IMUCTORRS INCH DO NOT HAZE CO rA JACKETS SHALL BE 10811 FED MBE BY APPROPRIATELY COLORED TAPE. ALL UNUSED CONDUIT AND MIRE TO BE MOM RACK TO SOURCE. INCLUDING PL.LIG —MI CIRCUIT BREAKERS ON WSW. FEEDERS TO PANELS MO BUSWMS SHE! ON SLEETS E2 AIM E3 DINO LABEL. ALL. RECEPTACLES, JUNC11011 BOXES, WOES, EX., wN CRCIIIT ENIEICA110N. INSTALL REUSED PALL SCHEDULES UPON COMP E11ON OF d08. VERIFY ROTA11ON OF ALL 3 PHASE MOTORS. � tEt FOR SWIG DIAGRAM SEE 1E502 FOR OUST COUECIER N1FJilA('J( DIAGRAM 1E11O C!T' 'lF T!.JK►'; ILA CCU 4 ZOO? .J E 411 t: Intl Pim * Firs 1341 NW mows.. J•101rw. 011110110 IN NICISMI P.T. N. MENTA R. “004 N. lA 5-25-94 F Repro Rooftop Cllr 10 -19-64 K. DOM a WSW 12 -1147 794105-00 Aisd. Row Aids 4/2!/00 —1116441116. W . man ituir g',1,..AurArzAvair S BUILDING 13 - 01.1 pFC7RICI► POSTER 004 ME (0 -13 277/480V POWER PLAN a C NIL 13- 01 -1E111 { a a s • • • a • S u • vi'► MAR 14 2004 •, I R � WEI r=111:31 NI IIIINiwiabiadmilmillIllel11111111111111111111 IIIIIII En aiiiimirk4 AA addi1111111111111111111 EMI MI IMIrimiii•iiiiiiill111011111111111111111111 ME ME El 1111 10011111.1111111111111111111111 NM MIMI El ormiiiiimmoilhdidiiiiiiimml111111111111111111111 mum mem 111C. r ► -- run . . � f „ " ",,.,i -10T MOM ra r .771=1111 • TMt 410411PWATIF moor aisiemmurawmai .I /wlPlLr/M/ IA�KITIt� 91PAIITNNT O w O 1 w� O go. RAW& 11111 _ra•M.r. . X All ..1! ' odow r+Iwo 11111111WINI OM Inighwor. 16MP liangling ME MI6 ILA rrri ilia ••1111 Of rirr, 0. I I e. r 1 • .. p • 1 • a • t ti • 4 • • . I