Loading...
HomeMy WebLinkAboutPermit M02-238 - SOUTHCENTER MALL - SOLE OUTDOORSSOLE OUTDOORS 925 SOUTHCENTER MALL 0. (ow wo u Z� I- Z►- W 0— o1— WW u' O tit . Z co OF M02 -238 1 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Permit Center Authorized Signature: Signature: doc: Mech City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 2623049004 925 SOUTHCENTER MALL TUKW SOLE OUTDOORS 925 SOUTHCENTER MALL, TUKWILA, WA JG SOUTHCENTER LTD 25425 CENTER RIDGE RD, CLEVELAND OH Contact Person: Name: DAVE ANDRINGA Address: 340 UPLAND DR, TUKWILA, WA Contractor: Name: SEA AIRE INCORPORATED Address: 340 UPLAND DRIVE, TUKWILA, WA Contractor License No: SEAAII *206JQ DESCRIPTION OF WORK: REPLACE AIR HANDLER HEAT PUMP IN BACK ROOM WITH ANOTHER 4 -TONE YORK UNIT, SUSPENDED FROM CEILING - UNIT WEIGHS 73 LBS. Value of Construction: $3,200.00 Type of Fire Protection: SPRINKLERS MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: MO2 -238 12/11/2002 06/09/2003 Phone: Phone: CELL 206 510 -4606 Phone: 206 575 -8051 Expiration Date: 04/18/2004 Fees Collected: Uniform Mechnical Code Edition: Date: 7,- /i-r) $46.50 1997 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Date: 1A- Print Name: b A A ( A in- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. MO2 -238 Printed: 12 -11 -2002 Signature: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 2623049004 Permit Number: MO2 -238 Address: 925 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 12/05/2002 Tenant: SOLE OUTDOORS Issue Date: 12/11/2002 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206 -835- 1111). 4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 5: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 6: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 7: Manufacturers installation instructions required on site for the building inspectors review. 8: ** *FIRE DEPARTMENT CONDITIONS * ** 9: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 10: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1646 - NFPA 72 11: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) 12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 13: Duct smoke detectors shall be capable for being reset from the alarm panel. (City Ordinance #1900) 14: Duct detectors shall send a supervisory signal only upon activation. 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) 16: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 17: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 18: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Gc41444 MO2 -238 Date: / . — (( — o 2 Printed: 12 -11 -2002 Project Name /Tenant: -50 l 6 6,1 0 i Signature: Value of M hanical Equipment: `P ...30.113c::, Site Address : /# Se. i ( Mn-f City State/Zip: Tax Parcel Number: 6 a Tot,- 90 0 1/ Property Owner: WEST frieL o . 4 I.1t €•c4 2 ,Jc- Cit / State/Zip: Tv L-w► i c.4 0 $ 14)(1,f Phone: ( ) Street Address: City State/Zip: Fax #: ( Contractor: ✓`// — At re c+-r✓ c- Phone: ( 204 ) 5 (05 j Street Address: /„4o u et gru o b rL -- ry kw,Lh City State/Zip: q9 l?? Fax #: ( ) 2,6. S"75 - - o b Phone: ( ) ai f 20c. sic. -Y60 v Fax #: ( ) 2 c s- 'f- o 6.5 .3 Contact Person: D ,q-o E Aw 02, ,1) G /I-' Street Address: City State/Zip: - ,,.-, upLA--"iJ 02- -1%rkL,./,:, OPier `BUILDI ° WNER OR' AUTHORIZED AGENT: Signature: Date: j2 „ d _ 0 1._ Print name. ffvE �t! 0 4. A Phone: ( ) b S' /.o • t /t o G F x #: ( ) S 75 C! to 5 Address: `() U f z4-nt( L - Cit / State/Zip: Tv L-w► i c.4 0 $ 14)(1,f CITY OF " * IKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Number: 001- gV Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specific): /- J� PL 4 c 19,12 /T1»' �Q./L 11{4.7 P ,9 ! ✓1 4/ 14, root, �j✓ t.�- � J9 N � �'t+ C�Z ��I * � 7EY+ Yo rk vv i - ' j S •-dsp-a-•, Fr om Ct1 ;I - ✓n :7" kl e1hr 3 ids Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: /.2 - 5' -02 Date application expires: Application taken by: (initials) ZteS 09/1 0/2002 ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment (including commercial kitchen hoods) weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal 09/10/2002 miscpmt.doc NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change - out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Payee: SEA -AIRE TRANSACTION LIST: ACCOUNT ITEM LIST: doc: Receipt City of iukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049004 Permit Number: MO2-238 Address: 925 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 12/05/2002 Applicant: SOLE OUTDOORS Issue Date: Receipt No.: R020001728 Payment Amount: 46.50 Initials: SKS Payment Date: 12/11/2002 02:26 PM User ID: 1165 Balance: $0.00 Current Pmts Amount PLAN CHECK - NONRES Type RECEIPT MECHANICAL - NONRES 000/322.100 Method Description Payment Check 038582 46.50 Description Account Code 000/345.830 9.30 37.20 Total: 46.50 3795 12/11 9716 TOTAL 46.50 Printed: 12 -11 -2002 *wen, ronot. re W g N N W QQ O. d : tit ILI D O. . �' O I— W r `1. w U= ~ O F- z Pr ct: • .. Type of Inspe twon: Address:- _ Date Called: Special Instructions: �p i ., ` ^ � % V � � e . Date Wanted• a.m. t � i p.m. Requester L.� 4 Phone No cell # 2 ) 77q - I n(o3C.P CTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSP.ECTION - RECORD Retain a copy with permit PER N (206)431 -3670 Appr ved per applicable codes. El Corrections required prior to approval. COMMENTS: 1 a _ 70 -)''7 r $4 INSPECTI9N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 South nter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Projec 5,, Oc7 ��s Type of I s ectio -�' G` Ad ress: > Date Called: Special Instructions: P D&—P7. 1 Ibis' .S/4./t iv (1,.411_..3t2 M/N . Date Wanted: f —/ ' D3 i m Reque Dazt& h P Ia No: el21o 779 64 4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT (2 . 6)431 -3670 a Approved per applica le co "� ® Corrections required prior to approval. COMMENTS: rtit J--T � 9 ,off►, ni. x spec Dater 47.00 REINSPECTI9N FEE REQUIRED: Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: !Date: �s '� , a #`f�s ' fir : z'i s. M .`2'L2Ae'�b�•.�..'i:'3Mw�',`�4 6. iYYicJ34a er - . �4i�a- u�:d:Si;::�ti >ar- ,i:`�..+F.x �..�Lf5:'a"..•:.t, Project: - ,' :.:.. : ,,'. " 2,GL` . ;0c17 -O/P S Type of Inspection: f /.UZL- Address: 9� T ',•;--- ur-/(Z ig4 Date Called: / — 6' — 03 -- n. Special Instructions: .' • "�(JL� ' ' l� .. 30 : ... Date Wanted: f —, _a3 (.; Re uester: Phl 8 � . J 779 .> t. 4« .t%ncr!3E;'!.3;' ?�'�n:ri:.�:�., ..,. .:. Ir is :!:ova;,tr•,,:1;�r.:'tt:+' �.�.`.b �iY' INSPECTION NO: 'TUKWILA BUILDING DIVISION 300 Southcenter Blvd:, #100, Tukwila, WA 98188 Approved :'per applicable codes. INSPECTION RECORD Retain a copy with permit COMMENTS: .4, al / ar t kod D 4.4) e %<-4.7u // A a le $4740.REINSPEGTION E REQUIRED. Prior to inspection, fee must be paid att300 Southcenter Blvd., Suite 100. Call to schedule reinspection. J Receipt ,N�. : 'Date: • K Corrections required prior to approval. PERMIT • ► .�1 i (20. 4 1 -3670 z r U0 WO N O Zo W Ij U � 0— O w I-. 9 - - O W Z = O F- Project: `Al ( -Pre . Sti le's Type o spectio : ,,,,,,,r Ad ress: / f ( J �f / i%.f'�'� PLC: Al/L5 Date Called:: p� / o� - i0 - o a Special Instructions: Ai/ Tire g, n Date Wa ed: / ? O � a:m: Requester: 2> / Phone No: No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit COMMENTS: 2-) 1/4 ‘, rag CA) �4 • r Corrections required prior to approval. Ati $47.10 . " NSPECTION F REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: .�i �`'.4. +, i:�:i.;.r:•T, "'.;: ir:..,, ,.r,- �.:r�r.�n ,,.,�.r:� ,xl�, ...+.r..: �:�.:... -_. ..- ..��.+�.yU` ..rjcs'!:s «�i4tC ^i' '.4i�?C�- ,i'��;tij •ii..i.'v,':k:ay;A�' `,V. r W 00 u) 0 �w N U- w g Q w Z � ZO 11.1 w D O O N 0 H W W H L. O .. co O Z FILE COPY SEPARATE PERMIT I understand that the Flan Check approvals are subject to errors and omissions and approval of I REQUIRED FOR: plans does not authorize the violation of any edopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. SO/e 0 Moo 4,5 II MECHANICAL If ELECTRICAL g PLUMBING alfGAS PIPING —crry—of—T-UKVVI BUILDING DIVISION 1E7 — Bate o 2.- Perm L • id ' Et- P4061,.. IitE1.1: &kg. DevA A IA Moncild k ,e0gc K. ko 13 i%11 ffp Qj . . I . 1- . 1 "Lft RECENED , IT'' ''," TUKWILA 01 LI tiL 5 :14 . DEC 05 2002 .c. a 0 r; g DI:: 0 - ff • , - Pt:Fowl CENTER 0 0 an.id 73(1)s - 11 3 C " e - PV* 111111=111" MEN 1 o fF GRow4 Ca An, Zr tkat. SA osti MODEL DIMENSIONS WIRING K O's REFRIGERANT CONNECTIONS A H C D E F G H J K LINE SIZE Height Width Total Heigh Power Control liquid Vapor N1AHt308t 17-1/2 47 -1/4 or 52.1/4 Depend -ing on corn- bination. 16-12 16-1/2 1/2 — 7/8 (1/2), 1- 3/8(1) — -- 1 -1 16.1/2 16.12 1/2 — 7/8 (1/2), 1 -38(1) — — 7/8 (1/2), 1- 3/8(1) Nl • } 24-1/4 21 10.3/8 20 20 12 — 7/8 (12) — — 1 -23/32 (1.1/4) N1AH014 24-1/2 23-1/2 22-1/2 1 — 7/8 (1/2), 1-3/8(1) — — 24-1 23-1/2 22-1/2 1 — 1 -31/32 (1 -12) — — G2F0024S(H)17 23 1742 18-3/8 — 16.12 — — 3/8 5/8 G2F0030S(H)17 23 17-1/2 16-3/8 — 16-1/2 — — 5/8 )17 26 17-1/2 16.3/8 — 16-1/2 — — 3/4 GZF0036S(H)21 23 21 19-7/8 — 20 — — 3/4 G2FD048S(H)17 28 17 -12 16 -3/8 — 16-1/2 — — 3/4 G2F0042S(H)21 23 21 19-7/8 — 20 — 3/4 �rc7j�.��rZr(;)7 ;tom 21 19 -7/8- — 20 — -- 7/8 S�aj�:�� °i:ly� 28 24-1/2 23.3/8 — 23-1/2 — — 7/8 )24 28 24-12 23 -3/8 — 23-1/2 — — 7/8 G2FD061H24 33 24.12 57.1/4 23-3/8 — 23-1/2 — — 7/8 036 - 21019 -003 Rev. A (6/00) DIMENSIONS - (BLOWER WITH GSFD COILS) NOTES: Power wiring maybe brought Into the unit through one of the knockouts in either the top or the right side panel. Multiple knockouts are provided to accom- modate all of the electric heat and transformer accessories that are available Use the knockouts that provide the best wire routing for the accessory being used. F 22 All dimensions are in Inches They are subject to chance without notice Certified dimensions will be provided upon request. . Parenthes s Indicate conduit size t. May be either 208/230-1-60, 208/230-3-60, 115-1-60 or 460.3.60 AIR HANDLER TOP (ALL MODELS) G A (Air Handler) A (Coil) C (Total Height) I,.--7 -1 /2 A 1 0-3/ AIR HANDLER BOTTOM OPENING 4 -1/8 COIL BOTTOM OPENING CITY Of TIEW1LA APPROVED 1 -1/2 1/2 DEC 1 0 2002 rs tiU ILU Ertitt_DIKG f)M9?QTi RECEIVED CITy OF TUKWILA DEC 0 5 2002 PERMIT CENTER Unitary Products Group . • ' - MODEL N1AH • C16 014 020 46 06 . -- 01 06 46 r- ---..-- liiib7Mociii_ I 1. • -.- i -Hester ArMs . ........ AmpacityMin. Circuit_ .... ______ Max. 0 C P2 Amps . _ __.:. Wire Size - AWG 75•C_ 10x 10 240V 11 x 10 208V 0 -, 240V 1/2 208V 240V 206V 3/4 240V N-AHB0808 2111( 65002068 • 1080 10 4 1065 13 3 460 • 14.6 ....--...- 115 -,... 15- . - - 15-....... .. 14., ,..... 14 - c, 21 5.1 / 44 20 8 Locked Rotor 247 • .“ 27.7 8.4/73 25 30 10 88/83 10 . MC85008068 66/60 31 3 73/67 355 • , 40.7 40 45 :, - - ::-. 8 -. i I. .,.? 8 - ••. - . 21-W65010088 41 7 48.9 i 53.7 50 60 B 8 • - N-AHB1206 • -- - - 2H1C•85005068 20.8 26 8 - 29.5 30 • 30 10 10 2HK•1350080613 31.3 37.7 42.6 - 40 MC65010066 ' -. - 41.7 • -- - 49.1 - - ' • 55.6 • - ' 50 - • • 60 - • 2H1(185015068 • 625 • - 71 9 ' 81.6 80 90 4 3 2141(165018068 733 83.3 95.2 90 100 3 3 2111(185019068 211K•135005068 73.3 208 83.3 276 95.2 30.2 90 - • 30 • 100 35 3 10 3 8 . _. N-AHC1608 . . 2HIC85008088 31.3 38.4 432 40 45 8 . 8 211C850100613 41.7 49.8 562 50 60 8 6 2141(165015068 625 727 • 823 80 90 4 3 2HK1650200813 83.3 949 108.3. 100 110 3 2 mi N.a ism 2111(435005068 208 266 293 30 30 10 10 2HIC*650080613 31.3 37.4 423 40 45 8 8 21-W65010368 41.7 48 8 553 50 60 8 6 2H1(1650150613 625 71 7 81 4 80 90 4 3 r44011)2006 2141(*650080613 31 3 398 443 40 45 8 8 21-W65010068 41 7 51 2 573 60 60 6 8 2111(185015068 82.5 74.0 83.4 80 90 • • 4 3 2111065020068 833 963 109 4 100 110 3 2 2HK1650250613 104 2 119 1 135.5 125 150 1 to 2HK16503008A 125 0 141 3 161 5 150 175 1/0 2/0 . • ' - MODEL N1AH • C16 014 020 46 06 . -- 01 06 46 06 Blower - Diameter x Width 10x6 10 X 8 10x8 Blower - Diameter x Width 11 x 10 10x 10 11 x10 11 x 10 11 x 10 Motor HP 1/2 .. 1/3 3/4 3/4 3/4 Nominal RPM 974 1075 1080 1100 1065 Voltage 460 208/230 115 208/230 460 A . mps ' Full Load 18 3 0 / 2 7 9.8 5.1 / 44 23 Locked Rotor 26 4 8 / 4 1 213 8.4/73 45 El / Operating Weight OW ) 73/67 88/83 91 91/85 91/85 • " - - • " MODELN1AH ' B08 B12 C16 06 01 06 46 01 06 Blower - Diameter x Width 10x6 10 X 8 10x8 10x8 11 X 10 11 x 10 Motor HP 1/4 1/2 1/2 1/2 1/2 1/2 Nominal RPM 1075 1075 1075 1049 974/855/885 1085 Voltage 208/230 115 2081230 460 115 206/230 Arnim Full Load 1.6 / 1.4 8.8 3 3 / 29 16 - 8.1 3 8 / 3 Locked Rotor 33/2.9 152 7 4 / 6 5 33 13.1 4 8 / 4 0 Shipping / Operating Weight (bs.) 60/54 66 66/60 66/60 73 73/67 ,* 1 1 . ' r * .; 4Nt44344r.r...4 . -1-Yas,icz.",-,tr.p.0.- •••••• - • ; coeurn'te,,ApAcliy 0110:y 1 , s - • ? - I , „cr„Sil ••,. 1, • e ;!. .-6:41. I - ELECTRICAL DATA (FOR SINGLE SOURCE POWER SUPPLY)COPPER WIRE 208/230-140 •. 30 KW 3 phase not approved for single source power supply. BLOWERS • .- - • - • • . - - - v4ito 'ma - • .RECEIVED -ITY OF TUKWILA -- bEC. 0 5 2002 PEA: tio .urf:.,t? trr...nrf Group • Products •••-, • • • • k ade'AFtr.- January 2, 2004 Dave Andringa 340 Upland Drive Tukwila, WA 98188 RE: Permit Application No. MO2 -238 925 Southcenter Mall Dear Permit Holder: City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to February 11, 2004, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer Permit Technician Xc: Permit File No. MO2 -238 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431.3665 June 6, 2003 Dave Andringa 340 Upland Drive Tukwila, WA 98188 RE: Permit Application No. MO2 -238 925 Southcenter Mall Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to July 6, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director Stefania Spencer Permit Technician Xc: Permit File No, MO2 -238 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206.431 -3665 June 6, 2003 Dave Andringa 340 Upland Drive Tukwila, WA 98188 Dear Permit Holder: City of Tukwila Department of Community Development Steve Lancaster, Director RE: Permit Application No. MO2 -238 925 Southcenter Mall In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to July 6, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer Permit Technician ✓1- g r o r' atA. ! /15; € c/L / m • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. Xc: Permit File No. MO2 -238 Bob Benedicto, Building Official XA I4aeI , diff'c.'z -r °t^-yA .4 /Ar l^ et, 1 0,-1 w 4 2 CITY OF T KVVNA J U L 0 1 2003 PERMIT CENTER / or oh 0-1,- � f ;A/('4- F 4r f'`^�✓ 41. 5- ite- knriar/ 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206 -431 -3665 Steven M. Mullet, Mayor ' :Qf ee 0,1 ,4- ACTIVITY NUMBER: MO2 -238 PROJECT NAME: SOLE OUTDOORS SITE ADDRESS: 925 SOUTHCENTER MALL DATE: 12 -05 -02 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: 1-10 Building Division n Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Bliti Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: F J COu o PLAN REVIEW /ROUTING SLIP 70 .4W& Iz /Ovz Fire Prevention Efl Structural ❑ Incomplete Approved ❑ Approved with Conditions [ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2.28 -02 PERMIT COORD COP`( Planning Division Permit Coordinator DUE DATE: 12-10 -02 Not Applicable ❑ DUE DATE: 01-07 -03 ❑ x DATE: z W U 00 co Cl wLU CO W w o u _ v ZO Dc UJ Li) ON O Ill w 1-- U. O ti. Z U= O 2 /./3 5 - 0 EAsr9 k, w s En ✓i /Jf ,tiPl, t:5 - ` ii.. • F625. Mtii97i F625.052.000 (8/97) F625.032.000 (8/97) (2V) ( 29(: S1(." DEPARTMENT OF LABOR AND INDUSTRIES LICENSED AS PROVIDED BY LAW AS ELEC CONTR HVAC /RFRG LICENSE # EXP. DATE EC6A SEAAII *005KK 05/29/2004 EFFECTIVE DATE 05/12/2000 SEA —AIRE INC 340 UPLAND DR TUKWILA WA 98188 DEPARTMENT OF LABOR AND INDUSTRIES CERTIFIED AS PROVIDED BY LAW AS ADMINISTR HVAC /RFRG :CERT # EXP . DATE AD6A -- MCCURJM000KK 05/23/2004 EFFECTIVE DATE. 05/12/2000 MCCURRY, JOHN M 32611 SE 44TH ST FALL CITY WA 98024 DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL - "`REGIST. # EXP. DATE CC01 "' *206JQ 04/18/2004 EFFECTIVE DATE 04 /18/1980 SEA AIRE INC 340 UPLAND DR TUKWILA WA 98188 (24› 2 '(8 -b t s' • •