Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M02-242 - BAHAMA BREEZE
M02 -242 BAHAMA BREEZE 15700 Southcenter Pkwy. City of Thkwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 MECHANICAL PERMIT Parcel No.: 1157200292 Permit Number: MO2 -242 Address: 15700 SOUTHCENTER PY TUKW Issue Date: 02/04/2003 Suite No: Permit Expires On: 08/03/2003 Tenant: Name: BAHAMA BREEZE Address: 15700 SOUTHCENTER PY, TUKWILA WA Owner: Name: JG SOUTHCENTER LTD Address: 25425 CENTER RIDGE RD, CLEVELAND OH Contact Person: Name: WAYNE MILLER Address: 4321 2 NW, SEATTLE WA Contractor: Name: ERICKSON COMMERCIAL RFRG INC Address: 4321 2ND AVE NW, SEATTLE, WA Contractor License No: ERICKCR088BL DESCRIPTION OF WORK: INSTALLATION OF WALK -IN COOLERS & FREEZER, UNDER COUNTER & COOLLINE REFRIGERATION REMOTED TO ROOF Value of Construction: Type of Fire Protection: doc: Mech Phone: Phone: 206 - 321 -3101 Phone: 206 - 789 -4722 Expiration Date: 01/31/2005 $22,000.00 Fees Collected: Uniform Mechnical Code Edition: $252.75 1997 Permit Center Authorized Signature: l' GU�� C ? ( ( Date: 6 /Dc- /O I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructio or the performance of work. I am authorized to sign and obtain this mecha ic permit. Signature: Date: 2 _ Print Name: a / C (.4JE ,f /mil t f-L This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. MO2 -242 Printed: 02 -04 -2003 Signature: Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1157200292 Permit Number: MO2 -242 Address: 15700 SOUTHCENTER PY TUKW Status: ISSUED Suite No: Applied Date: 12/18/2002 Tenant: BAHAMA BREEZE Issue Date: 02/04/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835- 1111). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Readily accessible access to roof mounted equipment is required. 7: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 8: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 9: Manufacturers installation instructions required on site for the building inspectors review. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. iic(Ac PERMIT CONDITIONS MO2 -242 Date: 1./ 11? Printed: 02 -04 -2003 Project Name /Te t: Signature: Value of Mechanicaquipment: Site Address : S I ) �� r z all tk iV City State/Zip: Tax Parcel Number.. � C /S 0: 4- = 4 t - 7Z — Property Owner: ' 67 Phone: ( ) Street Address: S 700 So t� ��-t f �) .j / r K!C 7 City State/Zip: Fax #: ( ) Contractor: � C a1 t 1 . 6 , U iAr - 46:i c/'47c,e - ? nA..) Phone: (--7, ` °4' 75T Street A dress: Z 7 A) al .- � City State/Zip: 2 .. Q - - fi g / 07 Fax #: ( ) 2 °( T?; di qz/ Phone: ( ) , , 2cti a Z? ?! U I Contact Person: a/AL/ J - 4. /-{. i Ll- , Street Address: � � 2 -- ) 2_/ S �(g1 07 Cit State/Zip: Fax #: ( ) _, -2 "7 I ? I BUILDINGsO :AUTHORIZED AGENT :. Signature: Date: i i el o z____. Print name: W ky�g.— . i Phone: ( .2) 321 .� ( Fax #: 2CYo ) 7es u/4,4 Address: ,� '' !! u City / State/Zip: ' 67 Mechanical Permit Application Project Number: Permit Number: JA0.1_414L_ SIAI I US! ONI Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. CITY OF T 'KWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 M ECHANICAL PERMIT. REVIEW: AND APPROVAL REQUESTED: (TO BE FILLED OUT BYAPPLIC4NT)' Description o work /Jto be done (please be specifii�c): //y y1 69 77 % /J / . COOL (/J lQWM6 7s•.J ( z z 11 &, m 40 Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: ( -D3 Application taken by: (initials) 09/10/2002 ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment (including commercial kitchen hoods) weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. New Single Family Residence �. t Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements Heat loss calculations or Form H -6. Equipment specifications. Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. 09/10/2002 miscprnt,doc Change -out or replacement of existing mechanical equipment Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 1157200292 Permit Number: MO2 -242 Address: 15700 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 12/18/2002 Applicant: BAHAMA BREEZE Issue Date: Receipt No.: R03 -00101 Payment Amount: 252.75 Initials: LAW Payment Date: 01/30/2003 11:52 AM User ID: 1630 Balance: $0.00 Payee: ERICKSON COMMERCIAL REFRIGERATION TRANSACTION LIST: Type Method Description Amount Payment Check 12698 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000/322.100 000/345.830 252.75 202.20 50.55 Total: 252.75 1.' i TOTAL _ 2 / doc: Receipt Printed: 01 -30 -2003 PERMIT NO.: 1 -' 04t- MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 2 Pre- construction (� 50 WSEC Residential ❑ 60 WA Ventilation/Indoor AQC ❑ 610 Chimney Installation/All Types ❑ 700 Framing ❑ 1080 Woodstove 1090 Smoke Detector Shut Off 1100 Rough -in Mechanical 1101 Mechanical Equipment/Controls 1102 Mechanical Pip/Duct Insul 1105 Underground Mech Rough -in 1115 Motor Inspection 1400 Fire - Final 1800 Mechanical - Final ❑ 4015 Special -Smoke Control System CONDITIONS iff' 10001 No changes to plans unless approved by Bldg Div 10002 Plumbing permits shall be obtained through King Co } 10003 Electrical permits obtained through L & I 10005 All permits, insp records & approved plans available i ▪ 10014 Readily accessible access to roof mounted equipment it. 10016 Exposed insulation backing material 10019 All construction to be done in conformance w /approved plans t 10027 Validity of Permit 10036 Manufacturers installation instructions required on site ❑ 10041 Ventilation is required for all new rooms & spaces ❑ 10042 Fuel burning appliances ❑ 10043 Appliances, which generate. ❑ 10044 Water heater shall be anchored.... Additional Conditions: TENANT NAME: t\ ` FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace/Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor - mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (q ty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP/1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm/Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter SS) Add'l Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'l Plan Review (hrs) Plan Reviewer: Permit Tech: Date: Date: Project:, -I � jc/ q 'Type of Inspection: /fi Address: uate Calle ____, Special Ins ructions: f Date Wanted: a ye Requester: . � Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (20 PERMIT 7.177 �1.;. h,(l A per applicable codes. Ei Corrections required prior to approval. COMMENTS: AL $47.00 REINSPECTION A REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: ���.::.. a :�- i:•....`. —_ t:�.LlfdL.. r- �'"::6S "`:.':o...LM �� u:�i:.a 4t ��.: ..Aw'. )431 -3670 Projec,t / S01-e---lita ce. Ze Lee- Type of Inspection: Address: /.5100 S C- Date Called: 4 -/- - --- Special Instructions: Date Wanted: '-/- -,i$ (a.m., p.m. Requester: ' 6 ' L.c i / 7 4- Phone No: 3:-2/-3/a/ 2, INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 L .ef fe 4.4/61,/ 107)-7, 0 77-- R az, c;r- INSPECTION RECORD Retain a copy with permit (206)431-3670 Ei Approved per applicable codes. Corrections required prior to approval. COMMENTS: tf-)7 ' frie /01/1 #0 .0 /'j 7 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r eceipt No.: 'Date: -"igfagraila P r t; a (,u u'zia . e -t" Type of I ection: � -__ - in Ad re s : S Date Called: /P Special Instructions: +bate Wanted: t a.m. Requester: /// 1 a n pt .3,, _____ ? INSPECTION RECORD Retain a copy with permit INSPECTION NO.' CITY.OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 154 Approved per applicable codes. Corrections required prior to approval. COMMENTS: L i spector: Date: a...� z / I) .00 REINSPECTION FEE QUIRED. Prior tq inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call o schedule reinspection. eipt No.: 'Date: 206)431 -3670 do Monday, February 03, 2003 1:41 PM To: Pen rat-Desk Erickson Commercial Refrigeration, Inc 206 789 47 fax 206 783 8194 Monday, February 03, 2003 Pages: 3 Subject: permit application #MO2 -242 to: Permit Desk City of Tukwila Building Department Fax: (206) 4313665 We are installing refrigeration equipment at the new Bahama Breeze Restaurant project in Tukwila. I understand that our permit is ready for release, except that our state contracting license had not been renewed. Apparently our certificate of insurance had gone astray, but this has been rectified now. I just checked the L &I website & they now have us listed as 'active'. I'm hoping this will enable us to pick up the Tukwila permit. Thanks for your help & patience. Dale Erickson, ECR, Inc From: Dale Erickson, 20F.783 8194 Page: 1 of 3 CITY OF TUKWILA FEB - 3 2003 PERMIT CENTER tI to 3 O D O O N O H w w u o .z U 0 z Friday, January 24, 2003 12:33 PM 1 /24/03 To: "Mr I lelson From: Dale Erickson, 20 1 8194 Erickson Commercial Refrigeration, Inc 4321 2nd Av N W Seattle WA 98107 (206) 789 4722 FAX (206) 783 8194 Mr Ken Nelson City of Tukwila Permit Center 6300 Southcenter Boulevard #100 Tukwila, WA 98188 RE: development permit •applic M 02 -242 Bahama Breeze Restaurant project Page: 1 of 1 RECEIVED JAN T 4 2003 x, COMMUNITY DEVELOPMENT Mr Nelson: Our firm has applied for a mechanical permit for the installation of remote refrigeration equipment on the above project. Its our understanding that a permit is also required for the erection of the walk -in cooler & freezer enclosures, but on this project that is not part of our scope of work. We have been hired by the manufacturer of the refrigeration equipment, Coldzone of Brea California, to perform the installation as part of the package they sold to the owner or to the owners' kitchen equipment contractor. The cooler & freezer enclosures will be assembled by another entity, who will have a separate agreement with one or the other of those parties. Our foreman, Wayne Miller, told me that we need to document our non - involvement with that part of the work to clarify the distinction & allow our permit application to be processed. That's the aim of this memorandum. Thanks for your consideration, Dale Erickson, ECR Inc CO. TION LTR# M01-244- January 6, 2003 Mr. Wayne A. Miller Erickson Commercial Refrigeration 4321 2° Northwest Seattle, WA 98107 City of Tukwila Department of Community Development Steve Lancaster, Director RE: CORRECTION LETTER #1 Development Permit Application Number MO2 -242 Bahama Breeze —15700 Southcenter Parkway Dear Wayne: This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time, the Fire, Public Works and Planning Departments have no comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `revision sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, Stefania Spencer Permit Technician encl xc: File No. MO2 -242 Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206 -431 -3665 BUILDING DIVISION REVIEW Date: January 2, 2003 Project Name: Bahama Breeze freezer & cooler permit application Application #: MO2 -242 Plan Review: Ken Nelsen, Senior Plans Examiner Tukwila Building Division 6300 SouthCenter Blvd. Tukwila, WA 98188 206 - 431 -3670 An initial Building Department plan review can not be completed without additional information. Please address the following comments with revised plans, specifications, and /or other applicable documentation. 1. Provide additional documentation for the construction of the actual cooler and freezer shells, (wall, ceiling, and floor construction). Include the manufacture's specifications, installation instructions and any applicable product listing information. Should there be additional questions on these comments, please feel free to contact the Building Division office at 206-431 -3670. No further comments at this time. U Q LLI (1)1 w g 4 d . I- 0 z r w no o- oI wW im o .z w O ■ ACTIVITY NUMBER: MO2 -242 PROJECT NAME: BAHAMA BREEZE SITE ADDRESS: 15700 SOUTHCENTER PY DATE: 1 -24 -03 Original Plan Submittal Response to Incomplete Letter # X . Response to Correction Letter # I Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Documents/routing slip.doc 2-28-02 PLAN REVIEW /RMING SLIP Comments: Permit Center Use Only 'INCOMPLETE. LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete:. Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Permit Center. Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Fire Prevention Structural Incomplete n Planning Division ❑ Permit Coordinator DUE DATE: 1 -28-03 No further Review Required DUE DATE: 2 -25-03 El Not Applicable El Not Approved (attach comments) ❑ DATE: Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: All 02- 242- ❑ Response to Incomplete Letter # Response to Correction Letter # ❑ Revision # after Permit is Issued City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Project Name: 3Lh L 4'Lev Project Address: I970 0 Spliikilr,01461 1 Contact Person: ( L ' t i C zik} Summary of Revision: A IL 1(44at tk# 1,7 0' d f- -U -/--o3 . Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision iii. �---' Received at the City of Tukwila Permit Center by: 61 Entered in Sierra on / -2'103 Phone Number: 08 /30/00 Monday, February 03, 2003 1:41 PM To: Permit Desk LICENSE DETAIL INFORMATION Form Page 1 of 2 Current Filter: None STATE OF WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES Specialty Compliance Services Division P. O. Box 44000 Olympia, WA 98504 -4000 THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS: LICENSE DETAIL INFORMATION Registration# or License ERICKCR088BL Name ERICKSON COMMERCIAL RFRG INC Address 4321 2ND AVE N W Address City SEATTLE State WA Zip 98107 Phone Number 2067894722 Effective Date 1/13/1992 Expiration Date 1/31/2005 Registration Status ACTIVE Type CONSTRUCTION CONTRACTOR Entity CORPORATION Specialty Code GENERAL Other Specialties UBI Number 601282422 'VIEW *VIEW CROSS REFERENCE FILE FOR THIS LICENSE* * * 'VIEW *VIEW PRINCIPAL OWNERS) FOR THIS LICENSE* * * * * *VIEW CONTRACTOR BOND /SAVINGS INFORMATION * * * * * *CHECK INQUIRY FOR SUMMONS AND COMPLAINTS* * * * * * VIEW CONTRACTOR INSURANCE INFORMATION * * * New inquiry by CITY , NAME , PRINCIPAL OWNER NAME , LICENSE , UBI NUMBER , check the L &I Contractor Industrial Insurance Premium Status or return to the L &I Construction Compliance Home Page https : / /wws2.wa.gov /lni/bbip /TF2Form .asp ?license= ERICKCR088BL From: Dale Erickson, 2n' 133 8194 Page: 2 of 3 RECEIVED CITY OF TUKWILA F EB - 3 2003 PERMIT CENTER 2/3/03 a. REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL DEPARTMENT OF LABOR AND INDUSTRIES • z it 2 00 co CO W. co u. u j r ' w _ ca z 2 a 0 0 co: 0 — '- 0 I— UJ 11- . 0 TOP ROW A B I C G I H J J K BOTTOM ROW 0 GINERAL NOTES REFRIGE CATION PE SIZE E F BEEN BASED ON PAF TIAL P. --',S r RE IYFORMAI N ^ I$C =COSEC HERE!! 1 I ALAS ORC :KATE= BY A.N5 6 HE PRoP- �RTY OF COLEVONE AND EXCEPT FOR K:GHTS EXPRE GRAN TE D TO THE ;USTOMER. CO 5ZONE RFS _RUES AL_ :)AT ENT, PROP[ ^ 'Y, DESICP . USE. `;ALE, MANUFA:"URING Ahj REPRODUC- "ION RIGHTS T _RETO. GINERAL NOTES REFRIGE CATION PE SIZE SELECTION`; AND RO JTING HAVE BEEN BASED ON PAF TIAL P. --',S AND SPECIF,CATIONS AND ARE TO SE USED AS A GU17E ONLY. COLDZONE DOES NOT AND WI _ NOT ACCEPT RESPONSiB'-jTY -OR PIPE S!ZLNG. DISTANOES. VERTICAL R'SES AND REFRIGERAT ON PIPE STING ML ST BE BA;,ED ON ACTUAL J03 SITE C(AD'TIONS. IT IS THE INSTALLING CC:NTRJ CTORS R`SPONSIP'JP( TO FGLL C'W ALL APPLICABLE CODES ! CURRENT REFRIG -„ TON ,NDLSTRY STANDARDS AND P VACT:CES 'A/HEN INSTALL'.NG C' ,ARG•NO AND STARTING UP i HE SYSTEMS. FiI_` COPY .- 3rstard that ire : an Check approvals are _- . ,ect to errors anc : and approval of . .:nE does not alfthc ^:e the violation of any j -- )pted code or ordnance Receipt of con- ;tors cony of approvei plans acknowledged. By J -. I : _ -. Date Perris; No, _ "!KVv';LA 1 REVISE SYS % k B - item 528 TO 82 ITEM 68 DELETED 8/c6/02 0 INITIAL RELEASE 5/4/02 i REV DESCRIPTI I n.,TE i TYPICAL WIRING DIAGRAM FOR FIXTURES OR COOLER WITH '20 VOLTS FAN MOTORS GROUND EVAPORATOR COIL B1 55 B2 i 523 F 7 G 13A H 13A c COV2.NAnON skirt FOUR 8<SE COVIINAnON PANTRY BA',E RE BASE CO 1,/3 NATION SAUTE COLD RAIL PANTRY COLD RAIL BEER COOLY WAU< -t!: COOLER w K - IN FREEZER K11 2400 SRF ICE uACHINE KM 2400 S.W ICE MACHINE 1000 MR ICE MACHINE KF.1 1600 M.RF ICE MACHINE -10 -20 22 KAE0075 3/4 5.4 , 208 404A I CSI2K6E ZS19K4E 2.5 7.5 208 404A 404A 404A 404A I 404A ZFO9K4E 3.0 11.1 208 3 10.1 40.2 40.2 G G 2 TT28 -13RF C 2 : TT28 -13RP COLDZONE 2.9 115 COLOZONE 2.9 11 C G 2 -13RP COLDZONE G 1 i MUF27 -17RP I COLDZONE CTE56 -12` COLDZONE CTE46 -100 COLDZONE AE34 -105E; I COLDZONE SUPPLIED BY OTHERS SUPPLIED BY OTHERS 2.8 4.4 1208 26.0 208 3.3 1 208 1 13.0 208 SUPPLIED BY OTHERS 17.0 26.0 14.4 3.0 115 1.5 115 208 17.0 M 5/8 B 1/2 B 1/2 M 7/8 B 5/8 B 5/8 S 7/8 S 1 1/8 1/2 S 1 1/8' 3/8 S 3/8 , 5/5 S 3/8 5/8 3/8 3/8 3/8 1/4 ' 3/8 3/5 5,8 TMR -LLS Ft Fl TmR -LLS , Ft ED -10 Ft Ft '?3 -20 I Fl F! I FI i F! M` R MFR ' MFR (s' =R MFR • MFR MFR MFR ;MFR MFR MEP. !.'FR cl CI 50B C2 559 LASER O OJT ONLY 0 1 SUPPLIED BY OTHERS t►SER CRG�'T ONLY 7.7 0 1 SUPPL!ED BY OTHERS -© LASER ORCJIT ONLY 21.6 • fl SUPPLIED BY OTHERS -©- COMPRESSORS ELECTRICAL CH<+RAC' ER:STIC AT 60 HZ. k10 1.0 4.5 208 3 EVAPORATOR COILS TYR -US RAIN TIGHT FLEXIBLE CCti :..,TS BY ELECTRICAL CONTRACTOR CONTROL CIRCUIT WIRING CONDU:T EL ECTR'Ck_ 80 G� 62` ELECTRICAL END TOP VIEW 88 88 �G Go 0 0 88 88 00 G FRONT VIEW 110 1. mac_ C,o oc, Go DRAIN LINE DETAIL REFRIGERATION LINES --� AIR FLOW (LOW TEMPERATURE ONLY) ELECTRIC HEATER SPIRALED AND TAPED ON FREEZER DRAIN LINE BEFORE AF'P_YING INSULATION BY PLUMBING CONTRACTOR 1/2" FALL /FT. MINIMUM - 7/8" NOM. COPPER ELECTRICAL CONTROL PANE_ WTH VJN -FUSED D :SCONNECT SWI :CH NOTE: POWER FEEDER '!R -NO CON JIT PLATFORM (BY G.C.) PLATFORM NOT SHOWN ON OTHER VIEWS -- UNION FINISHED ROOF TRAP 72" CURB OPENING FOR ELECT. UNES G.C. NOTES: Li (iii S .IGGESTED ROOF PAD DETAIL FT-3H v 3Dr LS 1 26" f T� SUCTION LINE 7/ LINE LINE SET 4� 1- PLATFORM TO BE INSTALLED LEVEL 2- PROVIDE SHEETMETA! HAT SECTION WITH WATER TIGHT SOLDERED JOINTS. 3 - BACK FILL OPENING WITH HOT PITCH AFTER INSTALLATION. "ET -3H" OUTLINE DRAWING NOTES; 1. UNIT WEIGHT IS 2,273 LBS 2. INSTALLATION CLEARANCE REQUIRES 3 FT ON ALL SIDES LINE SET SEQUENCE FACING UNIT 66.25" 4 35.25" CURB OPENING FOR REFR1GERAT!O'V LINES ENVIRO -THERM / ;;NIT S PLATFORM I (BY G.C.) A -' 0.0 O o0 REFRIGERANT END PIPING INSTALLATION TMR - WITH -LLS WIRING DIAGRAM 110" MOUNTED AT RECOVER) A s 1 3/4" PLYWOOD r- HAT SECTION I 20 GA. GAL 2` x 6' WOOD (TrP.) APPROX 12" OC SECTION A -A (TYPICAL) 62" - _ UL 12 MEA LEGEND SYSTEM ITEM NO: 103 COLDZONE ENGINEERING SUMMARY 0 - OFF CYCLE E - ELECTRIC C - GRAVITY [W/TIMER; e_ DEFROST CLOCK BY FIXTURE MANUFACTURER IND4c.ATEs PANEL �K L1 NOTE: - ALL LOW TEMPERATURE SYSTEMS ARE SUPPLIED WITH SUCTION UNE ACCUMULATORS FACTORY INSTALLED - EACH COMPRESSOR SYSTEM IS SUPPLIED WfTH A CRANKCASE HEATER AND HEAD PRESSURE CONTROL: FACTORY INSTALLED - REFRIGERATION SYSTEM INCLUDES A MAIN -FUSED DISCONNECT SWITCH; FACTORY INSTALLED - SYSTEMS A, B & C INCLUDE COPELAND SEMI - HERMETIC COMPRESSORS - SYSTEM D INCLUDES A COPELAND HERMETIC COMPRESSOR - SYSTEMS E & F INCLUDE COPELAND GLACIER SCROLL COMPRESSORS - TIME CLOCK FOR SYSTEMS A, B & C TO BE FACTORY SET TO TURN OFF AT 2:00 A.M. AND ON AT 10 :00 A.M. L1 12 TIME CLDCX LOCATED ON CONDENSING UNIT i (ED -20) (ED -10) AUX /1 R1 R2 RI INDICATES ELEC. PANEL ELECTRIC DEFROST WIRING DIAGRAM TIME CLOCK LACATFD ON CONDENSING UNIT To2A 0 I I 6 Uo. Sa.. oNWM.o F)RNN UNE HEALER °W V) P T -STAY NOTES; T. DRAIN UNE HEATER BY REFRIGERATION CONTRACTOR PROVIDE 6 WATTS OF HEATER CABLE FOR EACH FOOT OF DRAIN UNE. EXTEND HEATER CABLE TO FREEZER WALL WRAP HEATER CABLE AND DRAIN UNE WITH WSULAIION TAPE 2. WIRING: FACTORY WIRED. FIELD WIRING BY ELECTRI CONTRACTOR INDICATES WHICH COMPONENTS ARE LOCATED IN THE REFRIGERATION ELECTRICAL PANEL ELECTRIC DEFROST WIRING DIAGRAM ORAN UNE HEATER TB2A -N NOTES: 1. DRAIN LINE HEATER BY REFRIGERATION CONTRACTOR. PROVIDE 6 WATTS OF HEATER CABLE FOR EACH FOOT OF DRAIN LINE. EXTEND HEATER CABLE TO FREEZER WALL WRAP HEATER CABLE AND DRAIN LINE WITH INSULATION TAPE. 2. WIRING: FACTORY WIRED. FIELD WIRING BY ELECTRICAL CONTRACTOR. INDICATES WHICH COMPONENTS ARE LOCATED IN THE RE/ RIGERAT1ON ELECTRICAL PANEL S - 'SINGLE M - MAIN B - BRANCH I CONNECTED LOAD= 76.5 AMPS SUPPLY: 208 - 230V /3PH /60HZ . CONNECTED LOAD= 76.5 AMPS UNE SIZES •• * * VERIF'' UNE SIZES WITH JOB SITE CONDITIONS ,,.,,"•• o CHI` "' Z tT NG D�,`1Si0: C- �14N1 401104:010 ENGINEERING GUIDE SPECIFICATION FOR REMOTE REFRIGERATION PACKAGE ENVIRO -THERM REMOTE SYSTEM FUSE SIZE: 90 AMPS I kr" 1 M UM AMPACtTY= 79.3 AMPS ACCESSORIES SUPPLY CODES: MFR FURNISH WITH =IXTURE FL - CZ TO FURNISh AND SHIP LOOSE Fl - CZ TO FURNISH AND INSTALL ON UNIT RC - FURNISH AND INSTALL BY REF. CONTRACTOR THE REFRIGERATION PACKAGE SHALL BE A PRE - ENGINEERED AND FACTORY ASSEMBLED UNIT, TRADE NAME " ENVIRO- THERM", AS MANUFACTURED BY COLOZONE, A DIVISION OF HEAT TRANSFER PRODUCTS GROUP OF INC., 221 SOUTH BERRY STREET, BREA, CA. 92822. PHONE (714) 529 -4461, FAX: (714) 529 -8503. DEALER SHALL FURNISH AND INSTALL, WHERE SHOWN ON PLANS, (1) COI.DZONE U.L. APPROVED - ENVIRO- THERM" AIR- COOLED REMOTE REFRIGERATION PACKAGE, MODEL ET -3H WITH CONTROL PANEL 208 VOLT, 3 PHASE. 60 HERTZ. 1. ENCLOSURE THE FRAME SHALL BE MADE OF STRUCTURAL STEEL AND THE ENCLOSURE ANC PANELS SHALL BE MADE OF HEAVY GAUGE CARBON STEEL ENTIRE FRAME $H' LL BE PRE - ASSEMBLED, WELDED, :LEANED AND PAINTED WITH A PRIME COAT OF ZINC CHROMATE AND SHALL BE FINISHED WITH A CCAT OF EPDXY BASED 'ENVIRO- KOTE ". 2. REFRIGERATION UNIT ( ENVIRO- THERM) A. THE ENVIRO- -THERM REFRIGERATION UN T SHALL BE PROVIDED WITH SINGI E STAGE SEMI - HERMETIC COPELAND COMPRESSORS. MULTI - CIRCUITED MR- COOLED CONDENSER OPERATING WITHIN THE RECOMVENDED RANGE OF SUCTION AND DISCHARGE PRESSURE FOR WALK -IN COOLERS. FREEZERS & REFRIGERATED FIXTURES. EACH CIRCUIT OF THE MULTI- CIRCUIT CONDE .SER SHALL BE SIZED FOR MINIMUM OF 20 DEGREE F.T.D. B. EACH COMPRESSOR UNIT SHALL BE EQUIPPED WITH COPELAND COMPRESSOR, LARGE PUMP DOWN CAPACITY RECEIVER WITH TWO SHUTOFF VALVES. _ICuID LINE DRIER, SIGHT GLASS, SUCTION AND DISCHARGE VIBRATION ELIMINATOR, HIGH -LOW PRE SURE CONTROL CRANKCASE HEATER AND FLOOD HACK HEAD PRESSURE CONTROL FOR LOW AMBIENT - ALL FACTCRY ASSEMBLED. C. ALL COMPRESSOR UNITS SHALL BE NEW AND FACTORY ASSEMBLED TO OPERATE WITH THE REFRIGERANT SPECIFIED IN THE REFRIGERATION ENGINEERING SUMMARY SHEET. 3. PRE - PIPING A. ALL TUBING SHALL BE SECURELY SUP ? ^RTED AND ANCHORED WITH CLA.APS. B. ALL REFRIGERANT ONES SHALL BE EXTENDED TO ONE SIDE OF THE PACKAGE IN A NEAT AND ORDERLY MANNER. C. ENDS OF ONES SHALL BE CAPPED AGAINST CONTAMINATION AFTER THE UNIT IS COMPLETED. THESE CAPPED ENDS ARE TO BE OPENED ONLY AT FINAL CONNECTION OF THE PACKAGE TO FIXTURES. 4. CONTROL PANEL A. THE PACKAGE SHALL HAVE FACTORY MOUNTED AND PRE -WIRED CONTROL PANEL COMPLETE WITH INTERLOCKED MAIN FUSED DISCONNECT. COMPRESSOR CIRCUIT BREAKERS. CONTACTORS AND TIME CLOCKS WIRED FOR SING _E POINT POWER CONNECTION. B. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL MAIN POWER LINES TO PANEL, AND USE WIRE HARNESS WIRING FOR CONTROL AND DEFROST HEATER BETWEEN THE DEFROST CLOCK AND THE REFRIGERATION EAT, RES, ALL IN ACCORDANCE WITH THE WIRING DIAGRAM AND LOCAL CODES. GENERAL NOTES 1. GENERAL CONTRACTOR A. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND COORDINATE WITH OTHER TRADES. B. GENERAL CONTRACTOR SHALL PREPARE AND WEATHERPROOFING THE PLATFORM AND CURBED OPENINGS. 2. REFRIGERATION CONTRACTOR A. B. C. D. E. F. C. THE COMPLETE SYSTEM SHALL BE EVACUATED WITH VACUUM PUMP. ALL COPPER TUBING TO BE REFRIGERANT GRADE A.C.R. OR TYPE CHARGE. TEST, AND ADJUST EACH UNIT TO BE IN AN OPERATIONAL SYSTEM. SIL VER SOLDER AND /OR SIL -FOS SHALL BE USED FOR ALL REFRIGERANT PIPING. SOFT SOLDER IS NOT ACCEPTABL ALL PIPING TO BE PRESSURE TESTED WITH NITROGEN AT 300 PSI. AFTER THE CONDENSING UNIT AND COIL HAVE BEEN CONNECTED, THE BALANCE OF THE SYSTEM SHALL LE LEAK TESTED WITH ALL VALVES OPEN. REFRIGERATION CONTRACTOR TO PROVIDE AND INSTALL DRAIN UNE HEATER IN FREEZER TO BE CONNECTED BY ELECTRICAL CONTRACTOR 3. FI EC TRICALSAINTRACIGE A. ELECTRICAL CONTRACTOR TO PROVIDE POWER FOR REFRIGERATION PACKAGE AND CONNECT CONTROL AND DEFROST SYSTEM AS CALLED FOR IN THE WIRING DIAGRAM. B. ELECTRICAL CONTRACTOR TO PROVIDE COLOR CODED SERVICE FROM TIME CLOCK AT THE REFRIGERATION PACKAGE TO THE EVAPORATOR IN THE FIXTURE FOR DEFROST. ALL ELECTRICAL WIRING AND INSTALLATION SHALL BE IN ACCORDANCE WITH THE WIRING DIAGRAM AND LOCAL CODES. 4. PLUMBING CONTRACTOR A. PLUMBING CONTRACTOR TO PROVIDE HARD A.C.R. OR TYPE "L" COPPER DRAIN LINES FOR WALK - IN REFRIGERATOR AND FREEZER. PITCHED 1/2 PER FOOT OF RUN IN FREEZER, UNHEATED DRAIN LINE MUST BE OUTSIDE OF FREEZER WALL TO PREVENT FREEZING. TRAP DRAIN LINE OUTSIDE OF REFRIGERATED SPACE TO AVOID ENTRANCE OF WARM AND MOIST NR. PLUMBING CONTRACTOR TO PROVIDE INDIVIDUAL DRAIN LINE FOR EACH EVAPORATOR UNLESS OTHERWISE CALLED FOR. ALL PLUMBING INSTALLATION SHALL BE IN ACCORDANCE WITH LOCAL CODES. B. C. SEPARATE PERMIT REQUIRED FOR: r "~° _CHANICAL V ' ECTRICAL JMBING W -.as PIPING CITY OF TUKWILA L3UILOING DIVISION 'roster dwg revised on 2/23/99 oldZone 221 SO. BERRN ST. (714) 529 -446 \..., UREA, CA 92822 (714 5')9-HK( FAQ: 0°rc nt.t Nair vic1 ..across REFR G-_RA~`ION FLA\ BAHAMA RRI_EZE MO2Lf). TUKWILA. WA. _ AAA IN S. NUMBER 10542 DATE 5/24/02 ?4AWN BY %B TUKWILLAxts NOT PKAFW+ TO OGALE JOB N.MF3ER HEET NUMBER R -1 J 0 0 PLY SYSTEM ON 5.._T ION • PRE FINISHED ALLim GUTTER COLOR TO 1MATC-H S.P0...T5 CONNECTED TO STORM WATER E-E-LIER S- SPLASH BLOC< TYR - (SEE CIVIL • LNDC::.j, 5E E_LEvAMON TYPE ALL VALLEY W/2-0"" ALUM. F/EHINC EACH _ SIDE TIP_ - - - - LINE OF ROOF- ELOW - - PT WOOD S• JAKE (K19 c-■ ROOFTOP LIGHT FIXTURE SEE ELEC. DUJGS. (T)'P.) - - LINE OF ROOF BELOW A 2 ALL vALLEY t.11i -•- - TYP. ', LINE OF B.-II...DING •--".2,..:I-i- - — -------------1,--.1. _ •- •.S W HI C I Q N , ..7.-. r) L S E -' S 4 FC E _ . ... ._.... ... .., '------.._<:-----" -'• - . 1 41 - .2--L - -- - - -- - - - -- • -...- .- - - -- -- --- i.: 4'4 -. P,_- -4 - - ,-,-- OG) ® 1 0000 CO ® Dcz..4.N - SEE VA44 TAB LT.% • A' • -- - .4# • 1 I COJGAtED METAL ROOFING • ROOFTOP LIGHT FIXTURE SEE ELEC. D1i.65. (TYP) • . 041D 4 4 : IC 0. TROOP PLAN SCALE: lar = .40 4. _000 6,12 00 LUOC:i E 7 E. J t • eEE (R.:_ "7:F•I<..i.2. TAL — L GID INSJI A7ON o ee® ___,1 ___ _ _1 .. _ .__ _ - - - , ' ! \•.,,, -..,---..) i, 1 ' -- -- • 11 II 1 1 1 1 ! , 1 Iii!I 11 1 1 Lt • SINGLE PLY ROOFING SYSTEM ON RIGID INSULATION ALUM. GUTTER PRE FINISHED -(w/ DOWN SPOUTS - CONNECTED TO STORM • WATER SEWER SYSTEM OR sPLASH BLOCK - "MP. - (65E CIVIL , PRE FINISHED - 1" ALUM. GUTTER COLOR TO MATCH (El) W/ DOWN SPOUTS CONNECTED TO STORM WATER SEWER SYSTEM OR SPLASI-I BLOCK TYP. - (SEE CIVIL • • CRICKET 2XE, FT. WOO:: • -- pARAFET HIBUILT U' ROOF. SEE .9.:_ I/ATS (REFER TO 57R-CT) i 1 • I 0000 0 0000 0 .6A0 2 4-2._ P.T. •OOD SH,A•GE GE V ALUM, •:.:'...TTER PE-F. 7-0....1NSOLITS I tr:N.:7-0;.!J - N TYPE — 1' ALUT Csj77ER FE .S CO \NE-C.7E17 TC STORM LATER o SF'LAS;-1 BLOC< 17 - (SEE CVIL •,C0i- F!X1 SEE ELEC DWYGS. TYP.) 6514L "C.") ROOF 0R4!` - SEE IDET4!1_ 48 4 7 R OOFING .• . P.T. UJOOD SHAKE SHINGLE 0 0 0 0 ET-UP T4E OOF !NSUL47!ON •._ . CCKET 47 1 !,."/ FT. R Cr: OF !-;47C-4-! LELLC — 1 . MO).-aqa- GENES& NOTES 1. FOR ,..00ATION OF BEAMS AT CONNECTIONS BETWEEN PODS 4 MAIN BUILDING AND BETWEEN POD "B" AND PAVILION SEE SHEET A-623. 2. LOCATION OF ROOFTOP EQUIPMENT IS APPROXIMATE. FOR 4CTUAL LOCATION OF ROOFTOP OPENINGS SEE STRJC-TURAL DRAJING5. 3. SEE SHEETS SF-I AND SP-3 FOR FINISH MATERIALS AND FINISHES. .T.CNSTR...ST -sS SSE DE5CRFT L al_5■6\ 74E.CEON C2 11-1EIR CD :5 64-4A-1A BREEZE TLKWIL,4, wAs e 01-22 "---- ARCHITLLTS CS)! AKA IE1 Uccommn 77. •••,, 5..trf.200 S F57M-14 21.01 Wel ROOF PL Ecc .- sr VSJED j jmice.5 • 4C IDA. 5. (9 lie" A-4.0 E) NITROGEN ( "N") TANK F sumazgavow C51h1" 11t Len M. Oh 8100F; LOC°WE ON AFL i i � 0 t HIEMA"IC OF REFR'GERA'•IDA u'611,^w - 1439 TO A 9C&t JEA TO COLOZCNE SHOP ORS 7 -""r 2e Y -,. a ' <'x36 1t II F 4 1 ( 1 0 T L._ L bAs fi 19 ) i 8r P.G 461 1! 11 _ �s Ecl �I " _7A . T 1 V r 7 .T; ft. RIESIENCE w cones-vv SAN - 21R 1IILK MI6 ikerlaLlE, t11I PusiaaNIG ocr'Tallt O W..MIF ►I;. 001011114010 11 ^:aMR 'll nuvrea'.. RKA ay I 11141104m ITEM ?" SCOSIEI I(A:31t t' 001 UN 001A LOT 002 LOT 0021► LOT 0028 LOT 00.1 1 004A 1 0048 1 006 1 006A 1 0068 2 007 1 006A 1 0088 1 009 1 010 LOT 0'OA LOT 011 1 012 1 012A 1 0128 1 013A 2 0138 2 0130 1 0130 1 014 1 015 1 O15A 1 0158 1 016 1 017 1 017. LOT 017A 1 0178 1 018 1 019 1 019A 1 020 1 020A 1 021 1 022 1 023 LOT 024 5 025 1 026 LOT 027 1 027A 3 027B 2 027.2 LOT 028 1 029 1 030 1 031 LOT 032 LOT 033 LOT 034 1 035 1 035A 1 035.1 1 036 .3 037 1 038A 1 0388 2 038C 7 039 4 040 1 041 2 042 1 042A 1 043A 1 043B LOT 043C 1 043D 1 043E LOT 043F 1 044 5 045 1 046 1 047 1 047A 1 048 2 049 2 050 1 050A 1 050B 1 050C 1 051 1 052 1 052A 1 0523 1 052C 1 (1 STORAGE SFtE1Ylj SEC Raw LQtdOR I1.L11ES TAI RACKS .E34 S BEER COc -1 24 LIMITS a _ R. COOLER !s... S--E'_IAES 11A.AR BEER CO>GLER '91EFR COMER REMO TL 00910ENSING :5 :r ( +33 F) 6t_P COOLER (VAKIRATOR CCIL (4 - X,X-ER 1►Arl.RA CO,.tFR REMOTE CONOL tfSING LAO (, 3S T) M14-!cif CAO . ER : VAPO RA "OR COIL (4 35 IF) IAA_ KIN FREEZER IAA KIN FREEZER It1ElA;j ;E OOMOE116943 %KART ( -10 1) AA ADf FR!EUER EVAPORATOR al& ( -10 F) 'IF_G£TAe3..E DRYER OJ..ER/I RE EZER ? L1"JfG LEDGE RACKS AA'_ R F1L" L RS (0 rHE ICE YA ^.tNIES) PREP Saw FA :ET /SAN.T MALL SHZF ICE CURERS REMOTE FAN COILS ( COLDZONE) ICE CUBE? RE1rOTE FIN COIL ( COLDZONE) ICE BAN ICE RAKER REMOTE FAN COIL ( COLDZONE) CE F1MER/ CUBER SIN ICE BUCKET SHELVING SOILED D'SHTAB_E S/S WAIL PANELS PREWASH S NK DUMP SINK/ TROUGH AIR CURTAIN W/ M:CROSWTTCH DISHWASHER SOAP DISPENSER BRACKET CONDENSATE HOOD DUCTS. FAN AND CONTROLS - BY G.C. LCLEAN DISHTABLE W/ DOUBLE WALL SHELF DISH STORAGE SHELVING 'CUP AND LASS RACK COWES - BY OWNER t{ANC SINKS GAS BOOSTER HEATER CORNER GUARDS AND TRIM FLASHING WORK TABLE W/ POT SINK ,FAUCET PRE -RINSE SPRAY (SAN';TIZER) PREP UNE WALL PANELING WA_L SHELF / UTENSIL RACK DO LIKE CONVECTION OVEN WORK TABLE W/ WALL SHELF BAR MILLWORK - BY G.C. SPLASH GUARDS ?REP HOOD WALL PANELING POT FILLER FOOD HOLDING CABINET PASS -THRU FOOD CABINET PASS -THRU WINDOW FRAME COUNTER HAND SINKS W/ SPLASH GUARDS SET -UP COUNTER 27" DROP -IN HOT FOOD WELL 20' DROP -IN HOT FOOD WELLS HOT /COLD FOOD WELL FAUCETS COLD FOOD WELLS CHAR - BROILER SAUTE' BURNER RANGE THREE VAT FRYER FRYER FILTER SYSTEM PREP AREA EXHAUST HOOD DUCTS, FANS AND CONTROLS -- BY G.C. PREP AREA FIRE SUPPRESSION SYSTEM COOK AREA EXHAUST HOOD DUCTS, FANS AND CONTROLS - BY G.C. COOK AREA FIRE SUPPRESSION SYSTEM QUICK DISCONNECT HOSE KITS - NOT SHOWN 40 GALLON TILTING SKILLET 12 GALLON KETTLE DOUBLE STEAMER W/ STAND WATER FILTER SANDWICH WALL SHELVES SAUTE WALL SHELVES SAL' REFRIGERATED BASE REMOTE CONDENSING UNIT BY COLDZONE SAUTE' COLD RAIL REMOTE CONDENSING UNIT BY COLDZONE CHEESE MELTER BROILER REFRIGERATED BASE REMOTE CONDENSING UNIT BY COLDZONE REFRIGERATED BASE REMOTE CONDENSING UNIT BY COLDZONE /fy1 0 2 - 2_42 EQUIP?'ENT SCHEDI,LE MS -4 2 MS -5 1 MS - LOT MS -7 1 MS -9 1 MS - I MS -1 1 LOT MS -12 1 MS -14 2 MS -16 1 MS -17 LOT M MS S -19 -20 21 1 MS -21 1 MS -22 1 MS -23 3 MS -24 1 MS -25 1 MS -26 1 MS -27 2 MS -31 6 MS - MS -36 35 1 1 MS -38 LOT MS -43 LOT MS -44 LOT OS3 05'4 055 0548 O5 056 057 058 060 060 061 062 063 063A 064 064A 065 066 067 C67A 068 069 069A 0698 069C 070A 07011 0708 070C 0700 070E 071 072 073 074 074A 075 076A 0768 0760 1 tyldik+ Bnfi.A, CEWI'. R BASE EL" ORTIER PO4 „k c-LF A I 1 PAA WFRAJERA 3 t se "ff COUC9Evi \A, , " 11i txxxizatat 1 prke. COLD RAt. 1 ItEtiO - L Met w IOC J0111 BY 00.DZCI E 1 OESSER' "A' rT IKYIRCILRPOOR 4 FOX '11A RS 1 OD-RATER PfER Salk 3 S , P=' =5S GALAS 1 OESSt.RT lasal LOT FLOOR latLAr_ . OR&p t FOOD _R 1 PIZZA ONE % t DUCT. FAN ANC CONTROLS 3 PLATE IkAiog1NG CA8P T 1S 3 P_A'T trs:laNG uNTIS LOT IR,AS- - BY 01►ALR 2 DAPPER ■S_ 3 1 DROP -It ICE CR AN FREEZER 1 IC ", fEAW SWIM 1 P:ZIJA E - .i' FtER ATCR 2 P.C.S. CO.A"ER - BY G -C 1 8F'WAAGE COUNTER TOP 11/ S 2 BEVERAGE COJN'ER - BY C_C_ 1 BEVERAGE CC'JNTER LOP 1 EAR PREP C S P: E 1 LOT S/S WA_L PANE-WS 1 HAND SR< 1 FA:, CF'T SAN MR 1 BAR PREP DOUBLE WALL SHELF 1 BAR PREP S NK 2 COFFEE MAKER - BY VENDOR 3 COFFEE GRADER - BY VENDOR 1 CAPPUCCINO VAO.tNE 1 COUNTER TOP AT PCK -UP COUNTER 1 P'CX -UP COUNTER - BY G C. 7 MICROWAVE OVENS 2 SODA TOWER/ ICE BIN - BY VENDOR 3 C.ARBONATORS - BY VENDOR 5 BAR GUNS - BY VENDOR 076E 1 BAG AND BOX RACK - B`' VENDOR 076E 1 WATER FLTER 077 LOT P.0 .S. SYSTEM - BY OWIER 077A LOT PRINTER SHELF 0776 LOT POS PRINTERS 078A 1 DRA=T BEER REMOTE SYSTEM (MOuNTED ON BEER COOLER 0780 1 DRAFT BEER TAPPING EC) LIPMENT 078C 2 BEER TOWERS AND DRAINERS 079 2 FROZEN BEVERAGE DISPENSERS ORO 3 FROZEN BEVERAGE DISPENSER STANDS 081 2 FRO:EN BEVERAGE FREEZER - triple 1".1bble 082 2 SU;AR CANE JUICER 082A 2 S'.jGAR CANE JUICER STANDS 083 5 SLENDER STATIONS 083A 1 DRAIN BOARD 0E4 1 BAR SINK 085 2 BAR HAND SINKS 086 2 BAR SHELF 087 1 ICE CREAM FREEZER 088 ' ICE OKAY STATION 089 2 ekS REFRIGERATOR 090 7 ICE BATH BINS 0901 2 ICE BATH BINS tY.1 2 GARNISH RAILS 092 LOT HEAT LAMPS 093 2 }CEO TEA DISPENSER 034 LOT PLUGMOLDS 095 2 EXPO STATION SHELVES 096 1 MOP SINK RACK 096A 1 FAUCET 096B 1 CHEMICAL SYSTEM - BY VENDOR 097 1 HOSE REEL 098 - SPARE NUMV'ER 099 2 DRAIN BOARDS 100 1 MOBILE PRESSURE WASHER - BY OWNER 101 1 SERVICE STATION UNDERCOUNTER REFRIGERATOR 102 2 FROZEN BEVERAGE DISPENSERS 103 1 REMOTE REFRIGERATION RACK - BY COLDZONE 104 LOT CONDENSER FAN MOTORS - BY COLDZONE 105 - SPARE NUMBER 106 1 'BUS STATION 106A 1 SINK COUNTERTOP 1068 1 SINK COUNTER 107 1 REACH -IN REFRIGERATOR 108 2 PASTA COOKERS 109 LOT MILLWORK CABINETS 110 1 PORTABLE WORKTABLE (NOT SHOWN ON PLAN) SW -1 SW -2 SW -3 SW -4 SW -5 SW -6 SW -7 SW -8 SW -9 SW -10 SW -11 SW -12 S MALL WAR ES MISCELLANEOUS EQUIPMENT 2 KNIFE HOLDER (WALL MTD. C 48" AFF) 7 44" TICKET RAIL (MTD 0 HOODS, SHELVES, EXPO) 1 LARGE ICE SCOOP HOLDER (FRONT OF ICE BIN) 2 SMALL ICE SCOOP HOLDER INSIDE /EA SIDE SODA ICE BIN) 1 PAPER CUP DISPENSER (WALL 4TD 0 18" ABOVE TOP) 4 THERMOCOUPLE HOLDER (EXPO, GRILL PREP UNE) 6 72" TICKET RAIL (OVERSHELF 0 t.XPO) 1 TICKET TIME CLOCK (GRANITE SHELF 0 EXPO) 2 MERLIN TIMER (2 CHANNEL) (PREP LINE /EXPO) 1 CAN OPENER (END OF PREP TABLE) 2 DIGITAL CLOCK FOE EXPO (0 CLG, COOK /EXPO ON COL) 2 RERUN TIMER (12 CHANNEL) (0 FRY/ GRILL) MONITOR CASH DRAWER SHELF (MOUNTS TO UNDERSIDE OF BAR TOP) DRAFT BEER DRAINER (MOUNTS IN SHOT GLASS RAIL) CAN WASH S/S WALL PANEL HOSE REEL BRACKET (MOUNTS 18" FROM CEILING LINE) MAIN BAR SHOT RAIL MAIN BAR S/S TOP W/ DRAINER (MOUNTS ON BAR TOP /DIE) MAIN BAR S/S SHELVING / WALL PANELING DECK BAR SHOT RAIL (MOUNTS ON BAR TOP) SERVICE STATION PARTITION CAPS - NOT SHOWN CHARBROILER WEIGHT SHELF (SITS ON BACK OF GRILL) VERIFY COOKING AREA S/S WA,: PANELS MOPSINK TOOL BAR (MOUNTS 0 80" AF.F.) TICKET RAIL HOLDER (MOUNTS ON HOOD 0 CENTERLINE OF GRILL BUCKET BAR (SUPPORT ON TOP CORNER OF BIN) (NOT SHOWN) ICE SHOVEL HOOK (MOUNTS 0 48" A.F.F.) JUICER STANDS - NOT SHOWN WATER HOSE SUPPORT (MOUNTS 0 48" A.F.F.) PIZZA TOOL BAR (MOUNTS 0 72' A.F.F.) PIZZA PEEL BAR (MOUNTS 0 24" A.F.F.) HOTEL PAN RACK DOLLY - NOT SHOWN KABOB WEIGHTS - NOT SHOWN COOK AND CHILL BAGGER STAND (SITS ON PREP TABLE) DYNAMIC MIXER PARTS RACK (MOUNTS 0 30" A.F.F.) MIRROR TRIM (MOUNTS ON MAIN COOKLINE HOOD) MOP SINK WALL FACING AND CHANNEL CAPS SANITIZER TAGS (NOT SHOWN) ..VILA 'n7 WITH BAKER,' PRIDE & FRYER) l`JKw r UVI Zp JaN • ,R knl F ESTAURAhT SERVICES, INC. 290 E RA4DOL YL` 1 ROAD ARLINGTON. TEXAS USA 76011 817- 640 -5415 - Pi404E 817- 640 -7713 - FAX www.rsi.ac THIS DRAWING, THE DESIGN BHOw, AND THE EOUPYENT MIA . _D THEREIN. IS DE SOLE PROPER - Y OF RF STAURAAT STR." S. NG ANA R= ROOsCTD•i. OR .:SE OF r45 DRAONG W XIT THE EX??3S MR - TU.: CONSENT BY AN 0r)CER OF RS IS PRO•i19 AND ANY v1 1 X:L T w BE SJ9.E :„'T TO LEGAL ACTION. t 300L M. ROWLAND DATE - - -- 04/17/02 S_Ai.E NOTED ITEMS ON THIS rAGE EQUIPMENT SCHEDULE SVFET K1 SIXTEEN