Loading...
HomeMy WebLinkAboutPermit M02-243 - MARKET TRENDSMARKET TRENDS 375 CORPORATE DR SOUTH EXPIRED 6 -26 -03 M02 -243 t ut'.✓:. n•.; t:: N:.: h..: 4' e•.. a' x:¢ iiiik` J :twtYY +r+Js«•;J.'ti, {�.y�Ln4;f• c'U:4tih•X't,�tiGiti.'k:a:a'ey; £ Value of Construction: Signature: Print Name: doc: Mech City of'1'ukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049142 Address: 375 CORPORATE DR S TUKW Suite No: Tenant: Name: MARKET TRENDS Address: 375 CORPORATE DR S, TUKWILA WA 63 e_vrt W eAks MECHANICAL PERMIT Permit Number: MO2 -243 Issue Date: 12/27/2002 Permit Expires On: 06/25/2003 Owner: Name: MTI ENTERPRISES LLC 0 Phone: Address: 375 CORPORATE DR S, TUKWILA WA *1 Contact Person: Name: DOUG KOHLS Phone: 206-963-3858 Address: COMFORT MECHANIC 0 ST 6 r0O Contractor: JAN 2 Name: COMFORT MECHANICAL INC Phone: 425 - 251 -9840 Address: 6617 S 193 PL, #P -105, KENT, WA Contractor License No: COMFOMI015LA Expiration Date: 06/01/2004 DESCRIPTION OF WORK: REMOVE AND REPLACE THREE FAN - POWERED VAV BOXES AND 10 COOL ONLY. $45,000.00 Fees Collected: Type of Fire Protection: Uniform Mechnical Code Edition: $63.63 1997 Permit Center Authorized Signature: rl��L �� -'I > Date: / 02 0 7 ` 0 Z I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. MO2 -243 Date: 1 -- k"') — Printed: 12 -27 -2002 Signature: Print Name: doc: Conditions City of 'Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049142 Address: 375 CORPORATE DR S TUKW Suite No: Tenant: MARKET TRENDS PERMIT CONDITIONS Permit Number: MO2 -243 Status: ISSUED Applied Date: 12/18/2002 Issue Date: 12/27/2002 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835- 1111). 4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 5: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 6: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. S o'z,t r Web'o MO2 -243 Date: '.....? Printed: 12 -27 -2002 Project Na e/Tenant: Pi ar {'e+ T; L ER OR AUTHORIZED AGENT: City State/Zip: rAr.. • 0. / � Value of Mechanical Equipment: 4 its 00,00 Tax Parcel Number: rr // p / .. t 3 /''J' _ / /`' 7`'z Site Address : Ali' Property Owner: s aei.. Print name: /V/ git Phone: ( ) 3 _ 3 psi Street Address: Address: Gxr30 .5 aadf4 s� City State/Zip: Fax #: ( Contractor: rn ar1 y ( /4Ict Phone: (9.5 ) 05/ — 78'400 Street Address: C'y State/Zip: Gil Fax #: (WS ) d os / - ?V 7/ Contact Person: 9 Ye, 3 2_, Phone: ( 96 , 3 - 3 U S& Street Address: 6re30 S aan#I, 4 7 L City State/Zip: j 7L1 ` Fax #: ( .- ) BUILDING 0 ER OR AUTHORIZED AGENT: , JJ( Signature: 0'44 4 Date: / .. // - O Z Print name: (4 r s � !' � Phone: (,j ) 1,4 3 _ 3 psi Fax #: (SrJs 1p 5 _ p • r 1/ Address: Gxr30 .5 aadf4 s� City /State/Zip: k i i.✓L 9R A5_ • 09/1 0/2002 CITY OF T 'KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Number: Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. fe 3 MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specific): tre. Ur- (pa 4'0fikee $ 'ri.n fp.,1.te) t4e2I GI Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND l AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: - 1.g/-03 Application taken by: (initials) ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H,V.A.C, over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment (including commercial kitchen hoods) weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits 09/10/2002 niiscpnst,doc COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change - out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: TRANSACTION LIST: doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 2623049142 375 CORPORATE DR S TUKW MARKET TRENDS R020001791 KAS ADMIN COMFORT MECHANICAL Amount Payment Check 6126 ACCOUNT ITEM LIST: Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES Type Description RECEIPT Method Description 000/322.100 000/345.830 Permit Number: Status: Applied Date: Issue Date: Payment Amount: 63.63 Payment Date: 12/27/2002 08:33 AM Balance: $0.00 63.63 Account Code 50.90 12.73 Total: 63.63 MO2 -243 APPROVED 12/18/2002 " "P�I'nled: 12 -27 -2002 c..4 (A Z1 5 — eD E • • * 4 & : N E t..) cra tit' NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. Table Of Contents Product Summary 1 Variable Air Volume Fan Powered Terminal Units (Items Al - A3) Tag Data 3 Product Data 3 Mechanical Specifications 4 Unit Dimensions 6 Accessory g Field Wiring 12 Variable Air Volume Single Duct Terminal Units (Items B1 - B4) Tag Data 15 Product Data 15 Mechanical Specifications 16 Unit Dimensions 17 Field Wiring 21 FILE COPY approvals era fihe Plan Checic ap, � s a of understand that .7;t :', • to r:: to )(V) dUN 2 8 zoo CITY OF TUKWILA APPROVED DEC 19 2002 AS F,U tiltf3 ;k a 5 1 3 "� r) _...'.J I .l 2O MO43 Market Trends Ta'g' Data - Variable Air Volume Powered Terminal Units (Qty: 3) Model Number VPEF0803 VPEF1004 VPEF1206 Item . Tag(s) Al A2 A3 FVAV -1 FVAV -2 FVAV -3 Qty 1 1 1 Description 'Variable Air Volume Fan Power Variable Air Volume Fan Power Variable Air Volume Fan Power Product Data - Variable Air Volume Fan Powered Terminal All Units Parallel with electric heat 1/2" [13mm] matte faced insulation Slip and drive connection 277/60/1 motor voltage Single speed motor w/ SCR DDC with on/off electric heat control Left hand connection Power fuse 1 stage of heat 24 volt magnetic contactors Power disconnect switch Electric heater air flow switch Item: Al Qty: 1 Tag(s): FVAV -1 8" (203 mm) inlet size 03 fan 480 volt, 3 phase 4.0 kilowatt Item: A2 Qty: 1 Tag(s): FVAV -2 10" (254 mm) inlet size 04 fan 277 volt, 1 phase 4.0 kilowatt Item: A3 Qty: 1 Tag(s): FVAV -3 12" (305 mm) inlet size 06 fan 480 volt, 3 phase 15.0 kilowatt Units October 24, 2002 Market Trends October 24, 2002 Mechanical Specifications - W `ble Air Volume Fan Powered Terminal 'Item: Al - A3 Qty: 3 Tag(s): .AV -1, FVAV -2, FVAV -3 General Unit information Casing - The unit casing is comprised of 22 gauge galvanized steel. Outlet duct connection is flanged. Total metal encapsulation of all insulation edges. Hanger Brackets provided. Side access is provided. Filter - A filter is provided on the plenum inlet. Agency Listing - UL and Canadian UL listed as environmental air terminal unit. UL Control #9N65. All Trane terminal units are ARI 880 -98 certified. General Unit Clearance Leave a minimum of 36" [914 mm] on control box side of unit for adequate service access. Allow at least 12" [305 mm] on remaining sides for unit clearance. A minimum of one and one half duct diameters of straight duct work, upstream of the air inlet connection, should be present for optimum airflow measurement performance. Upstream duct work should be the same diameter as the primary inlet connection. 112" [12.7 mm] Matte - Faced Insulation The interior surface of the unit casing is acoustically and thermally lined with 1/2" [12.7 mm] 1.75 lb. /cu. ft. [28.03 kgs. /cu. m.] composite density glass fiber with 4.0 lb /cu. ft.[64 kg. /cu. m] high density facing. The insulation is UL listed and meets NFPA -90A and UL 181 standards. All insulation options will meet the 25/50 smoke developed and flame spread rating (per ASTM E 84 and UL 723 and CAN /ULC S102 -M88) Meets NFPA- 90B. The insulation R -value is 1.9. All cut edges of insulation are completely encapsulated in metal to prevent erosion. Air Valve- Fan Description (Parallel) (Series) The air inlet connection is an 18 gauge galvanized steel cylinder sized to fit standard round duct. A multiple point, averaging flow sensing ring is provided with balancing taps for measuring airflow within +/- 5% of unit cataloged airflow. Also provided with each unit is a calibration chart indicating airflow versus flow sensor pressure differential. The damper blade is constructed of a closed cell foam seal mechanically locked between two 22 gauge galvanized steel disks. The damper blade assembly is connected to a cast zinc shaft which rotates in a self lubricating bearing. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over stroking. Air valve leakage <1% at 4 ". 0803 Air Valve /Fan Combination Size (Parallel) (Series) Air Valve is 900 cfm [425 I/s ] 8 inch [203 mm] inlet. Fan is 1000 cfm [472 I /s]. 1004 Air Valve /Fan Combination Size (Parallel) (Series) Air Valve is 1400 cfm [661 Vs] 10 inch [254 mm] inlet. Fan is 1300 cfm [6141/s]. 1206 Air Valve /Fan Combination Size (Parallel) (Series) Air Valve is 2000 cfm [994 I /s] 12 inch [305 mm] inlet. Fan is 2300 cfm [10851/4 Motor Single Speed, direct drive induction, permanent split capacitor type. Thermal overload protection provided. Motors will be designed specifically for use with an open SCR which is standard. Motors will accommodate anti - backward rotation at start up. Motor and Fan assembly are isolated from terminal unit. ats Fuse Any electric heat unit with a calculated MCA greater or equal to 30 will have a fan fuse provided. SCR- Variable Fan Speed Control Switch The SCR speed control device allows the operator infinite fan speed adjustment so the fan output may be modified to achieve exact CFM requirements. Electric Heat Coil Factory provided and mounted. UL recognized, resistance open - type heater, a disc -type automatic thermal primary safety device and manual reset load thermal secondary device. Heater element material is nickel - chromium. The heater terminal box is provided with 7/8" [22 mm] knockouts for customer power supply. Terminal connections are plated steel with ceramic or phenolic insulators. Magnetic Contactor An electric heater 24 volt contact for use with Direct Digital Control (D.D.C.) or Analog Electronic VAV Controls. Power Disconnect A factory provided disconnect switch with an interlocking door on the electric heater control panel. Airflow Switch An air pressure device designed to disable the heater when the unit fan is off. Power Fuse A safety fuse located in the electric heater's line of power to prevent power surge damage to the electric heater. Slip & Drive Connection A slip and drive connection has two straight flanges on the top and bottom, and two drive connections on the left and right sides. The drive sides are straight flanges which form a "U" shape. The mating ductwork has ._....»' v4YAn@ 14X#"+°s Y7t'' �t. rx' tnnuctlwlnnrn+.... yw.. r.- ra�knrnYANJF� :7'"!AHYriMfiAEYi!�YlZlb�,l'7f. aV,. Market Trends October 24, 2002 a .i'milar setup. The two top and 'bottom pieces are shaped like a compressed "S" with sealant in the hollow of the "S ". These pieces will slide over the top and bottom straight flanges. The top and bottom flanges of the mating ductwork will slide into the otherside of these pieces. The two side pieces are shaped like a "C" and are called "Drives ". These pieces will slide over the "U" shaped flanges so the connection can not be pulled apart. These pieces are usually hammered into place. No screws are required, and by removing the drives, the ducts may be disconnected. D.D.C. Actuator Trane 3 wire, 18 GA, 3.4 VA, 1.7W, 24 VAC, 50/60 Hz. with floating point control actuator with linkage release button. Torque is 35 in -lb minimum and is non - spring return with 90 second drive time. Travel is terminated by end stops at fully opened and closed positions. An integral magnetic clutch eliminates motor stall when Trane controls are not provided. An integral 3 screw terminal is provided for field wiring. Operating temperature - 32/ 125 degrees F ( -0/ 52 degrees C). Direct Digital Controller The microprocessor based terminal unit controller provides accurate, pressure independent control through the use of a proportional integral control algorithm and direct control technology. The controller monitors zone temperature set points, zone temperature and its rate of change, and valve airflow, using a differential pressure signal. Optionally, the controller can monitor either supply duct air temperature or CO2 concentration via appropriate sensors. The controller is provided in an enclosure with 7/8" [22mm] knockouts for remote control wiring. A Irene zone sensor is required. System Communications The Controller is designed to send and receive data from a Central Control Panel or other Tracer family products, or a Varitrac CCP. Current unit status conditions and set points may be monitored and /or edited via this data communication feature. The network type is a twisted wire pair serial communication. Override Commands The following override commands may be received by the Unit Control Module (U.C.M.) from the Tracer System. DDC Sequence of Operation The unit controller continuously monitors the zone temperature against its set point and varies the primary airflow as required to meet zone set points. Airflow is limited by minimum and maximum airflow set points. Parallel Unit Fan Energization As the zone temperature reaches the heating set point, the microprocessor controls airflow to the heating temperature set point and energizes the auxiliary fan when necessary. At or below the heating set point, reheat is energized. The heating minimum airflow set point is factory set, field adjustable, and is separate from the cooling minimum set point. Parallel unit fan energization is a function of primary airflow or zone temperature. 1. Primary Airflow - The fan energizes when primary airflow drops below the fan set point airflow. The fan automatically starts when the zone temperature drops to the heating temperature set point. 2. Zone Temperature - The fan energizes when the zone temperature drops to a selectable number of degrees above the heating temperature set point. Controls Option DD04 Basic Operation: On /Off Staged Electric Heat (Normally Open Outputs) (DDC /UCM) (Parallel Units) A voltage signal from the zone sensor indicating zone temperature is used by the unit controller to determine an error from the set point. This error, as well as primary flow differential pressure, is used to determine damper position within minimum and maximum cooling airflow set points. As the zone temperature reaches the heating set point, primary airflow is controlled to the minimum heating flow set point. The fan operation is intermittent in both modes and is energized as the first stage of heat. The staged electric heat is energized for unit reheat. Unit Size VPEF0803 Nominal 203mm Valve Size [8.001 Inlet Nominal Fan Size 03 Fan Filter Size 20" x 20" x 1" (Qty 1) Weight lb Approximate Dry Weight 112 5� ti Market Trends Unit Dimensions - Variable Air `lume Fan Powered Terminal Units 'item: Al Qty: 1 Tag(s): FVAV- t 18kmm (8.5v') ACTUATOR 203mm (8.001 FLOW RING (AIRFLOW TUBING 140mm [5.50") 508mm 210mm [20.001 [8.251 AIRFLOW DISCHARGE OUTLET _ 1018mm [40.001 508mm [20.001 Weight reflected may vary t5 lbs (2.27 kgs) based upon options selected. TOP VIEW BACK VIEW m 0 548mm 121.501 CONTROL BOX ELECTRIC OR DDCIUCM FAN CONTROL BOX Customer Notes: I. Allow 152mm (81 clearance for plenum Inlet. 2. Allow 1219mm (48.001 of straight duct downstream of unit before first runout & Inside of the duct should be equal discharge elze.(Ax8). 3. Terminal box access door is side hinged. Allow for clearance. (fan sizes 01 & 02 are 432mm [161 long x 50088 ( [ 20") high; are s 03 thru 07 a 4. Filter mounted In filter frame. 5. Knockouts for power supply provided In top & bottom of terminal box. 8. Optional Slip & Drive Outlet Connection. 7. Coils are provided without Internal Insulation. If the unit Is to be Instated In a location with high humidity, external insulation around the heating coil should be Installed as required. October 24, 2002 tI Z ju 2 0 tom: to — 0 I- W rz L 0 W Z co 0~ z Unit Size VPEF1004 Nominal 254mm Valve Size [10.001 Inlet Nominal Fan Size 04 Fan Filter Size 20" X 20" x 1" (Qty 1) A Market Trends Unit Dimensions - Variable Air lume Fan Powered Terminal Units Item: A2 Qty: 1 Tag(s): FVAV -A 185mm [6.Sv ,] ACTUATOR 152 — m (6.Ov 140mm (5.50"] I 4 508mm 210mm [20.001 [8.25 "] 508mm (20.001 102mm/n(4.00 FLOW RING TUBING 254mm (10.001 AIRFLOW o- AIRFLOW DISCHARGE OUTLET TOP VIEW 1018mm [40.001 508mm - [20.00"] Weight lb Approximate Dry Weight 114 Weight reflected may vary ±5 lbs (2.27 kgs) based upon options selected. BACK VIEW 782mm [30.001 546mm [21.501 October 24, 2002 CONTROL BOX ELECTRIC OR DOC/UCM FAN CONTROL BOX Customer Notes: 1. Allow 152mm [81 clearance for plenum Inlet 2. Allow 1219mm [48.001 of straight duct downstream of unit before first runout & Inside of the duct should be equal discharge size.(AxB). 3. Terminal box access door Is side hinged. Allow for clearance. (fan sizes 01 & 02 are 432mm [18 1 long x 608mm �20' high) sizes 03 thru 07 are 4. Filter mounted In filter frame. 6. Knockouts for power supply provided In top & bottom of terminal box. 8. Optional Slip & Drive Outlet Connection. 7. Coils are provided without Internal insulation. If the unit Is to be installed In a location with high humidity, external Insulation around the heating coil should be Installed as required. Unit Size VPEF1208 Nominal 305mm Valve Size [12.001 Inlet Nominal Fan Size 06 Fen Filter Size 20" x 20" x 1" (Qty 1) Market Trends Unit Dimensions - Variable Air lume Fan Powered Terminal Units ' Item: A3 Qty: 1 Tag(s): FVAA -o 165mm [8.5v ACTUATOR 102mm /n [5.50") FLOW TU 140mm 508mm 210mm [20.001 (8.251 [4.00-1=-- RING BING 3 (20.001 is 305mm [12.001 AIRFLOW AIR VALVE 4 HEATER - b 102mm [4.001 TERMINAL BOX 51 508mm AIRFLOW DISCHARGE OUTLET w 1018mm [40.00' m m 0 508mm [20.001 Weight lb Approximate Dry Weight 144 Weight reflected may vary t5 lbs (2.27 kgs) based upon options selected. TOP VIEW BACK VIEW 1018mm [40.001 6.00" It 52mm) 546mm [21.501 CONTROL BOX ELECTRIC OR DDC/UCM FAN CONTROL BOX October 24, 2002 Customer Notes: 1. Allow 152mm lel clearance for plenum Inlet. 2. Allow 1219mm [48.001 of straight duct downstream of unit before first runout & Inside of the duct should be equal discharge alze.(AxB). 3. Terminal box access door is side hinged. Allow for clearance. (fan sizes 01 & 02 are 406mm (1 61 long x 60 �20 " high) sizes 03 thru 07 are 4. Filter mounted In filter frame. 5. Knockouts for power supply rovided In top & bottom of terminal box. 6. Optional Slip & Drive Outlet Connection. 7. Coils are provided without Internal Insulation. II the unit Is to be Installed In a location with high humidity, external insulation around the heating coil should be Installed as required. c 0 CO W 0 ` Q r w W Lu Q 0— t] H_ W W g U W U 0 z Market Trends Adcessory - Variable Air Volur 03 Parallel Fan Curve Item: Al Qty: 1 Tag(s): FVAV -1 1.00 0.90 0.80 0.70 0.60 3 0.40 H 0.30 0.20 0.10 0.00 0 200 400 an Powered Terminal Units L 600 Airflow (cfm) 800 1000 1200 Cooling only mudmum - - Minimum October 24, 2002 r 8 3 - 1 8 0 Total Static Pressure (Pa) 8 ••• • ..... ^ ..... as • ..... • S / .. ...... 0 3 3 3 8 P 0 8 0 0 Total Static Pressure (In. wg) 5 5 PP P 8 8 8 8 0 8 NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. 8 I . a 0 Tote( e Pressure (Pa o 8 -4 4. •z• 3 3 3 3 0 Sidle Pressure (In. wp) 0 0P 0 0 P P P P 8 0 8 8 88 8 8 8 • NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. IS> 3-og= .., R- 2.. Of -■ 0 ml g •• 2 g C " s t r, g 3 < fo 0 -4 0 3 C 3 ri Market Trends Field Wiring - Variable Air Vor 'a Fan Powered Terminal Units Item: Al, A3 Qty: 2 Tag(s): i• vAV -1, FVAV -3 Heater Control WIAnp /\ WARNING HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. FAILURE TO DISCONNECT POWER BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH ® CAUTION USE COPPER CONDUCTORS ONLYI UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO 00 SO MAY CAUSE DAMAGE TO THE EQUIPMENT. Customer Notes: 480 Vott, 3 Phase L3 L2 L1 b, b, 6 1. Factory Installed. Optional or Installed by others. October 24, 2002 z � W U W W : J N W , W O 1 Q tu F2 W uj 2 p: U co — . 0 H W W z O~ z Market Trends Field Wiring - Variable Air Vol! 'I Fan Powered Terminal Units item: Al - A3 Qty: 3 Tag(s): !- ,.AV -1, FVAV -2, FVAV -3 To Zone Sensor Connections on D.D.C. Board TB3 -1 TB3-2 I I 1 2 Zone Sensor Remote Mtd. To Zone Sensor Connections on O.D.C. Board N + 1 +? I ! I I- I- F- 5 4 3 2 Zone Sensor w/ Comm Jack Remote Mtd. Shielded Twisted Palr Communications Wiring In In Out Out O WARNING HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. FAILURE TO DISCONNECT POWER BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH /\ CAUTION USE COPPER CONDUCTORS ONLYI UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT. Wireless Zone Sensor Remote Mtd. No Field Wiring N a c N Electric Heater Contactor(s) 24 VAC, 12 VA Max/Coil N J11 J10 J9 J7 J8 T T a m F- m F I Field Installed Occupancy Detector D.D.C. \U.C.M. Control Board J r 1 1 1 1 4 5 1 2 3 Zone Sensor w /AdJ Setpoint and Comm Jack Remote Mtd. Customer Notes: T T 24VAC Fan Control Box Wiring m F- N F- F- m F- T -_ L �J I F- Field nstalled Aux. Temp. Sensor 1. Factory Installed. Optional or Installed by others. October 24, 2002 -I Optional Field Installed Carbon Dioxide Sensor Market Trends Field Wiring - Variable Air Vol a Fan Powered Terminal Unite Item: A2 Qty: 1 Tag(s): FVAb -i Heater Control Wiring A\ WARNING HAZARDOUS VOLTAGEI DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. FAILURE TO DISCONNECT POWER BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH /\ CAUTION USE COPPER CONDUCTORS ONLYI UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT. Customer Notes: 277 Volt, 1 Phase L1 N 1. Factory Installed. Optional or Installed by others. October 24, 2002 0 re 2 ui 00. co • ld • u. W LL Q' F W _! O UJ O • N 1- W W , � U LLO w z rJ ) . O Item Tag(s) Qty Description Model Number B1 SVAV -1, SVAV -2 2 Variable Air Volume Single Duct VCCF06 B2 SVAV -3, SVAV -4, SVAV -5 3 Variable Air Volume Single Duct VCCF08 B3 SVAV -6, SVAV -7 2 Variable Air Volume Single Duct VCCF12 B4 SVAV -8, SVAV -9, SVAV -10 3 Variable Air Volume Single Duct VCCF14 Market Trends Tag Data - Variable Air Volume `gle Duct Terminal Units (Qty: 10) Product Data - Variable Air Volume Single Duct Terminal Units All Units Single duct cooling only terminal Matte faced insulation - 1/2" (13 mm) DDC without remote heat - cooling only Left hand side connection (control & /or hot water coil) 120/24 volt transformer Power disconnect switch Power Fuse Item: B1 Qty: 2 Tag(s): SVAV -1, SVAV -2 6" inlet size, 500 cfm (152mm inlet, 236 Its) Item: B2 Qty: 3 Tag(s): SVAV -3, SVAV -4, SVAV -5 8" inlet size, 900 cfm (203mm inlet, 425 I /s) Item: B3 Qty: 2 Tag(s): SVAV -S, SVAV -7 12" inlet size, 2000 cfm (305mm inlet, 944 Ws) Item: B4 Qty: 3 Tag(s): SVAV -8, SVAV -9, SVAV -10 14" inlet size, 3000 cfm (356mm inlet, 1416 Its) October 24, 2002 Market Trends r Mechanical Specifications - V ble Air Volume Single Duct Terminal l s Item: B1 - B4 Qty: 10 Tag(s): SVAV-1, SVAV -2, SVAV -3, SVAV -4, SVAV -v, SVAV -6, SVAV -7, SVAV -8, SVAV -9, SVAV -10 General Unit Information The unit casing is comprised of 22 gauge galvanized steel. Outlet connection is slip and drive. Agency Listing - The unit is UL and Canadian UL listed as a room air terminal unit. UL Control # 9N65. All Trane terminal units are ARI 880 - 98 certified. General Unit Clearance Allow adequate clearance to meet NEC on control box side of unit to meet NEC. A minimum of one and one half duct diameters of straight duct work, upstream of the air inlet connection, should be present for optimum airflow measurement performance. Upstream duct work should be the same diameter as the primary inlet connection. 112" [12.7 mm] Matte - Faced Insulation The interior surface of the unit casing is acoustically and thermally lined with 1/2" [12.7 mm] 1.75 lb.cu. ft. [28.03 kg. /cu. m.] composite density glass fiber with 4.0 lb. cu.ft. [64 kg. /cu. m.] high density facing. The insulation is UL listed and meets NFPA -90A and UL 181 standards. The insulation R -value is 1.9. All cut edges of insulation are completely encapsulated in metal to prevent erosion. Air Valve Round The air inlet connection is an 18 gauge galvanized steel cylinder sized to fit standard round duct. A multiple point, averaging flow sensing ring is provided with balancing taps for measuring within +/- 5% of unit cataloged airflow. An airflow versus pressure differential calibration chart is provided. The damper blade is constructed of a closed cell foam seal mechanically locked between two 22 gauge galvanized steel disks. The damper blade assembly is connected to a cast zinc shaft supported by self lubricating bearings. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over stroking. At 4.0" wg air valve leakage does not exceed 1% of cataloged airflow. Air Valve Size - 06 Air Valve is 500 cfm [236 I /s] 6" [152 mm] inlet. Air Valve Size - 08 Air Valve is 900 cfm [425 I /s] 8" [203 mm] inlet. Air Valve Size - 12 Air Valve is 2000 cfm [994 Ifs] 12" [305 mm] inlet. Air Valve Size - 14 Air Valve is 3000 cfm [1416 Vs] 14" [356 mm] inlet. Slip & Drive Connection A slip and drive connection has two straight flanges on the top and bottom, and two drive connections on the left and right sides. This is a standard option on all VAV single duct terminal units. Control Transformer The 50 VA transformer is factory mounted in an enclosure with 7/8" [22 mm] knockouts to provide 24 VAC for controls. Control Fuse Replaceable fuse on primary voltage hot line. Control Disconnect A rocker switch which breaks both power legs entering controls box. D.D.C. Actuator Trane 3 wire, 18 GA, 3.4 VA, 1.7 W, 24 VAC, 50/60 Hz floating point control actuator with linkage release button. Torque is 35 in -lb (4 Nm) minimum and is non - spring return with a 90 second drive time. Travel is terminated by end stops at fully opened and October 24, 2002 closed positions. An integral magnetic clutch eliminates motor stall. When Trane controls are not provided an integral 3 screw terminal is provided for field wiring. Operating temperature is - 32/125 degrees Fahrenheit ( -0/52 degrees Celsius). Direct Digital Controller The microprocessor based terminal unit controller provides accurate, pressure independent control through the use of a proportional integral control algorithm and direct digital control technology. The controller monitors zone temperature set points, zone temperature and its rate of change, and valve airflow using a differential pressure signal. Optionally, the controller can monitor either supply duct air temperature or CO2 concentration via appropriate sensors. The controller is provided in an enclosure with 7/8" [22 mm] knockouts for remote control wiring. A Trane zone sensor is required. DDC Sequence of Operation The unit controller continuously monitors the zone temperature against its set point and varies the primary airflow as required to meet zone set points. Airflow is limited by minimum and maximum airflow set points. DDC Controls Option DD01 Basic Operation: Cooling Only Control (No Remote Heat) (DDC /UCM) A voltage signal from the zone sensor indicates the zone temperature is used by the unit controller to determine an error from the set point. This error, as well as primary flow differential pressure, is used to determine damper position within minimum and maximum cooling airflow set points. As the zone temperature drops to the heating set point, primary airflow is controlled to minimum heating flow set point. rml.mmm.w.v avor+xTR4�1\'gt'SW�' Market Trends Unit Dimensions - Variable Air' fume Single Duct Terminal Units • Item: B1 Qty: 2 Tag(s): SVA1►- ., SVAV -2 OPTIONAL (SEE NOTES) CONTROL BOX ANALOG OR DDC/UCM (PNEU. CONTROLS AREA) 185mm [8.50"] ACTUATOR SLIP & DRIVE CONNECTION TOP VIEW 210mm [8.251 140mm T [5.501 BACK VIEW Weight Ib Approximate Dry Weight 18 Weight reflected may vary t5 lbs (2.27 kgs) based upon options selected. 152mm [8.001 AIRFLOW 292mm [11.501 250mm [9.851 203mm [8.00'] 241mm [9.501 CUSTOMER NOTES: 1. See mechanical specifications for general unit clearances. 2. Air valve Is centered in unit front panel. 3. Slip & Drive discharge outlet standard. 4. Unit is fold- convertable from a left-hand connection (shown) to right -hand by rotating unit. October 24, 2002 1 Market Trends Unit Dimensions - Variable Ali ;lume Single Duct Terminal Units " Item: B2 Qty: 3 Tag(s): SVAV -J, SVAV -4, SVAV -5 OPTIONAL (SEE NOTES) CONTROL BOX ANALOG OR DDCIUCM (PNEU. CONTROLS AREA) 185mm (8.501 ACTUATOR 203mm - (8.001 AIRFLOW SLIP & DRIVE ,1. 102mm [4.001 279mm (11.001 October 24, 2002 • • E$ April 7, 2003 Doug Kohls 6830 S 220th Street Kent, WA 98032 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: Permit Application No. MO2 -243 375 Corporate Dr S Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final Inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to June 25, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer Permit Technician Xc: Permit File No. MO2 -243 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206-431-3665 DEPARTMENTS: � ,, A Building Division Public Works • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MO2 -243 DATE: 12 -18 -02 PROJECT NAME: Market Trends SITE ADDRESS: 375 Corporate Dr S ,Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued M5 t nl� 12- Fire Prevention • Structural ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Planning Division Permit Coordinator DUE DATE: 12-19-02 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route E' Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 1-16 -03 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: Documents/routing slIp.doc 2-28-02 z w 00 9 w 2 u.? N d LU Zo w 0 o 0 - 0 1— w Z U = 0~ z F625. 052.000 (8/97) F625 -052 -000 (8/97) DEPARTMENT OF LABOR AND INDUSTRIES LICENSED AS PROVIDE BY LAW AS ELEC CONTR HVAC/ RG 40'ttiGi4.`' :LIC ECSAr, s COMEOM . ;04D* 0• E EEQ;G CVEED ; COMFORT%.M HANICAL INC' 6617 S I • , `RD` .PL': P105: \'• i KENT W '98032 '4 ' 012000 y , DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONTT': CONT; - SPECIALTY � 7 ��i. . r r s R ',# eg ixP:;i�gD ATE :_ }� `EF' ECTIVEMD *TE01�5LA O 7 r 9 COMFORT -MECHANICAL INC !a,''•_1 6617 "SO 193RD PL #P -105 KENT WA 98032 File: M 02 -0243 35mm Drawing #1 -8 1 . 1 I i . • 0 Inch 1/16 ; ., 1. L ,fir nrrrnrrir t I II III�LIIIIIIII�IIII I IIII1IIIIIIIII�IIIIII r III�IIIIIIIIIIIIII�IIII�IIIIIIIII� 'lhlI IIII�I I IIII,1 IIIIIIII�IIIII11I �1I I III.111111111, III Market Trends : uilding (Controls Upgrade) 375 CDvp # fri.'1-e Dv . Tukwila, Washington 1 I ,,, '0 Inch 1/16 s v" f..... [Tr � lllllillllllllllllldIIIIIIIIIIIIIIIIIII IlllilllllIIIIII111 , .I a JUN 2 6 2003 I understand that the Plan Ch€;ck approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. �y -.•A Date Permit No. w Jirao 0 i�iilliii�ii ► iliiii�i�iillillliili. Iii�I �iilliilllI I IIllllII I ItII II IIIIIII1IIII�IIIII SEPARATE PERMIT REQUIRED FOR: 0 TA EC HAN!4 E ELECTRICAL ftePLIN12111G I GAS HMG Dirt OF TUKWILA BUILDING DIVISION BMS # DRAWING INDEX SHEET TITLE 1 INSTALLATION NOTES & BILL OF MATERIALS 2 BCU -1 FIELD WIRING DETAILS 3 FIRST FLOOR COMMUNICATION TRUNK DIAGRAM 4 SECOND FLOOR COMMUNICATION TRUNK DIAGRAM 5 AC -1 & AC -2 (MP503 -1) FIELD WIRING DETAILS 6 TYPICAL VAV TERMINAL BOX CONTROLLER DETAILS 7 VAV TERMINAL BOX ADDRESSING Mom a43 REVISION 0. SUBMITTAL SET 1. BOM UPDATE 2. FLOOR PLAN REVISIONS 3. 4. 5. SALES ENGR. MERTENS .t at PROJ. MGR. WEBB OT ' K\ ii__A Seattle District Commercial System Controls 2021 152nd Avenue Northeast Redmond WA 98052 APPL. ENGR. SCHULTZ DATE 12/06/02 DATE 12/06/02 12/12/02 12/18/02 PROJECT # MP -061 ITEM QTY MODEL# DESCRIPTION BCU -1 1 BMTWOOOAAOAO 5400A87010 BUILDING CONTROL UNIT (BCU) W /(x1) COMM 5, (x1) COMM 4, ETHERNET CARD, MODEM & TOUCH SCREEN DISPLAY 503 -1 1 • VRTO —DD01 —BLMO VAV RETROFIT KIT W /BELIMO ACTUATOR RTK -1 18 4950 -0490 TRACER MP503 INPUT /OUTPUT MODULE TS -2 31 4190 -1090 ZONE SENSOR W /ADJ, ON & CANCEL DAT -1 31 4190 -1100 SEALED ELEMENT TEMPERATURE SENSOR XFMR -1 2 MUC- 024 - 100- 2TF —CB 120/240/277/480Vac TO 24 Vac, 96 Va TRANSFORMER — CORE R -1 2 RH 1 B —U /SH 1 B -05 SPDT, 10 AMP, 24 VAC RELAY W /BASE — IDEC CSR -1 2 H708 CURRENT SENSING SWITCH 1 TR2256 TELEPHONE LINE PROTECTOR — TRANSECTOR ITEM DESCRIPTION VAV —__: VAV— • TRANE VCEF FAN POWERED VARIABLE AIR VOLUME BOX W /ELECTRIC HEAT — QTY.3 TRANE VCCF VARIABLE AIR VOLUME SINGLE DUCT BOX QTY. 10 WIRING NOTES EXISTING WIRING OR FACTORY WIRING BY MANUFACTURER ETHERNET CAT 5 CABLE: IF NON— PLENUM CABLE IS REQUIRED USE: CONNECT AIR PART # W244P -1026B IF PLENUM CABLE IS REQUIRED USE: CONNECT AIR PART # W244P -21766 CAT4 ECHELON CAT 4 CABLE: IF NON— SHIELDED CABLE IS REQUIRED USE: WINDY CITY WIRE PART # 105500 IF SHIELDED CABLE IS REQUIRED USE: WINDY CITY WIRE PART # 105600 SINGLE CONDUCTOR THHN AS REQUIRED BY CODE #18 TWISTED, SHIELDED PAIR: IF NON— PLENUM CABLE IS REQUIRED USE: WINDY CITY WIRE PART# 108760 CONNECT AIR PART # W181P -1060G IF PLENUM CABLE IS REQUIRED USE: WINDY CITY WIRE PART# 052003 CONNECT AIR PART # W181P-2028F #18/3C WITH SHIELD CABLE: IF NON— PLENUM CABLE IS REQUIRED USE: CONNECT AIR PART # W183C -1051 IF PLENUM CABLE IS REQUIRED USE: WINDY CITY WIRE PART# 180209 CONNECT AIR PART # W183C -2067 TRANE — APPROVED COMMUNICATION WIRE AVAILABLE THROUGH CONNECT AIR 1- 800 - 247 -1978, WWW.CONNECT — AIR.COM WINDY CITY WIRE 1- 800 - 379 -1191, WWW.SMARTWIRE.COM NO SUBSTITUTIONS WILL BE ACCEPTED. ALL OTHER WIRING SHOWS QUANTITY AND SIZE REQUIRED BY SYSTEM. REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. ALL 120VAC POWER WIRING TO TRANE PANELS MUST INCLUDE A SEPARATE GROUND CONDUCTOR. GROUNDING TO CONDUIT IS NOT PERMITTED. SHIELDED CABLE SHOULD HAVE SHIELD TERMINATED ONLY WHERE SHOWN. SHIELD TO BE CUT BACK AND TAPED AT ANY SENSOR. SHIELD TO BE TAPED AT ANY JUNCTION TO PREVENT GROUNDING. DO NOT RUN 30VAC OR GREATER AC POWER WIRES TOGETHER IN THE SAME CONDUIT OR WIRE BUNDLE WITH INPUT /OUTPUT OR COMMUNICATION TRUNK WIRES. INSTALLATION DETAILS REFER TO THE FOLLOWING TRANE INSTALLATION LITERATURE FOR ADDITIONAL INSTALLATION INFORMATION VAV —SVX01 B —EN: VAV INSTALLATION & OPERATION MANUAL TRANE EQUIPMENT SCHEDULE I I ' ' 0 Inch St fit t L .L :. 014 4 t* �� IIIIIIIIIILIIIIIIIIIIIIIIIIIIILIII [I�ILI HIM i 1 1 °i`Ti i i i ;I - � i i IIIIIIIII 1111111111111111111 ITEMS SHOWN ITALICIZED INDICATES CONTROLS EQUIPMENT TO BE PURCHASED BY TRANE "NEW EQUIPMENT" i L t 0 I I I I,1 I I I I I I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I BILL OF MATERIAL JUN 2 6 Z003 CITY ' +1 -' I"LIKVdILA 0 a. d z W 0 cc a. 1 0 z N 0 CD N 0 N \ N N • BMS I OF 7 t BCU DP ADDRESS *2345678 I 1 1 tPHI eee 1 — — — — — — — CATEGORY 5 10base —T UTP CABLE CAT4 ECHELON CAT 4 CABLE WIRING NOTES EXISTING OR FACTORY WIRING BY MANUFACTURER • — SINGLE CONDUCTOR THHN AS REQ. BY CODE #18 — • • — • • — • • — TWISTED, SHIELDED PAIR; TRANE APPROVED • • • — #18/3C WITH SHIELD CABLE; TRANE APPROVED TRANE — APPROVED COMMUNICATION WIRE AVAILABLE THROUGH CONNECT AIR 1- 800 - 247 -1978, WWW.CONNECT — AIR.COM WINDY CITY WIRE 1- 800 - 379 -1191, WWW.SMARTWIRE.COM NO SUBSTITUTIONS WILL BE ACCEPTED 1 1 . ' 0 Inch Is I • I' I • ; : c-1-... ,t, i -- ( IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII .IIII r WHITE (NEU) BLACK (HOT) BCU ADDRESSING DIP SWITCHES — 120 HOT — 120 NEU - — GROUND i — #12 GA. SEE RIGHT FOR ADDRESSING SETTING BUILDING CONTROL UNIT • i i t i i I • .( °i� -1 i � ._i i 7�. 1111! I1111111111111111111111111111111111111111111 , 1 . _, • DEDICATED 120 VAC CIRCUIT 7/7 BY ELECTRICAL CONTRACTOR ON OFF d - :O O LINK 1 ISOLATED COMM 5 CARD LINK 2 ISOLATED COMM 4 CARD EMPTY SPARE SLOT FOR FUTURE USE EMPTY SPARE SLOT FOR FUTURE USE UNIT CONTROLLER COMMUNICATIONS MODULES CARD SLOT 1 INTERNAL ETHERNET CARD SLOT 2 INTERNAL MODEM CARD SLOT 3 — EMPTY — 16 "W x 19 "H x 6 "D (407mm W x 483mm H x 153mm D) BCU -1 FIELD WIRING DETAILS (FIELD VERIFY MOUNTING LOCATION) P1 I _I, 1 S s s S TB2 2 10 11 12 P10 BLK . CAT4 3 ' "ahld 4 5 6 7 8 9 • L t o II II, �IIIIIIIIIIIIII�IIIIIIIIIIIIIIIIIII�IIIIillll�llI IIII I� NOTE: WALL JACK AND PHONE LINE BY OTHERS. I E ONrl OFF 61 SHADED PORTION INDICATES 105 Ohm SWITCH POSITION. RESISTOR COMMUNICATION LINK "1" TO MP503 -1 Buc t• ,1 - - — - - —.— COMMUNICATION LINK "2" -. TO 1st, 2nd FLOOR VAV BOXES " shld ETHERNET CONNECTION AVAILABLE FOR FUTURE USE. CONNECT PHONE LINE FROM INTERNAL MODEM, TO WALL JACK. JUN 2 0 Z003 C\ v t OF 1 1 3 O DEC 9 .r- ui a N 0 N N O (D a N N N • BMS 2 OF 7 WIRING NOTES EXISTING OR FACTORY WIRING BY MANUFACTURER CATEGORY 5 10base -T UTP CABLE CAT4 ECHELON CAT 4 CABLE - • --- • — • - SINGLE CONDUCTOR THHN AS REQ. BY CODE #18 - • • - • • - • • - TWISTED, SHIELDED PAIR; TRANE APPROVED - • . • — • • • - #18/3C WITH SHIELD CABLE; TRANE APPROVED TRANE - APPROVED COMMUNICATION WIRE AVAILABLE THROUGH CONNECT AIR 1- 800 - 247 -1978, WWW.CONNECT - AIR.COM WINDY CITY WIRE 1- 800 - 379 -1191, WWW.SMARTWIRE.COM NO SUBSTITUTIONS WILL BE ACCEPTED }llila I It • - I '-F CoM - ;.FFIC• F L� EE Ft-E J;I II TQF t.IEII — 1 —.. l yl ELECT! 1501 QEFICE TO M/ — • 'f`'? DETAI BC OR V DQTA I IT':HEII Cl II • FLI I3 I ' DFFICE ------- THERMOSTAT WIRING NOTE: LOCATIONS FOR REFERENCE ONLYI FOR EXACT LOCATIONS SEE MECH. DRAWINGS. - • • - • • - .. - BCU COMMUNICATION LINK NOTE: * INDICATES REQUIRED LOCATION OF A 105 OHM RESISTOR ALONG THE CAT 4 COMMUNICATION LINK. NORTH FIRST FLOOR COMMUNICATION TRUNK DIAGRAM '0Inch j 1 �IllilIIIILIIIIIIIIIIIIIIIIIIIIIIIII JIII RUN COMMUNICATION TRUNK TO ALL UNITS AND PANELS EXACTLY AS SHOWN OR VERIFY ALTERNATE ROUTING WITH TRANE. DRAWING SHOWN FOR REFERENCE ONLY. SEE MECHANICAL PLAN FOR ACTUAL LOCATION OF MECHANICAL EQUIPMENT. 6 I i i i . i . i .. .. l . L !i . 14 [ , . �l�lll" 179rrn � IIIIi. IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIh ,III1111 I$ - L E r, i o I (I I.IIIIIIIIIIIIIii 111 II I I I II I ILIIIIIIIIIII1 JUN 2 6.2003 1i 10 Iv I LI Lu {dl t: - I - 6� l . � . � P .I E I I ` I - Il j i ;I h- • CITY OF TI.W\W)LL APPROVED DEC 1 9 ZY.12 AS :lJ 1 L U 1_ C= 1 15 • 1 l rBi L, ..COMM CU -1 _LINIi2 1 I C;ITII ' JKv \VILA II gi CD O Ul O 0 I a 2 d z W 0 rt a 0 z o • C)m N 0 L d LL N 0 0 CD M O 0 0 • N 0 'ETA 0 0 E w z N j.70 1. N �QQ p E �3 N ELL' GDQNE WC.) CC BMS l3 OF N C I C) C C Cl) i co cO z 7 WIRING NOTES EXISTING OR FACTORY WIRING BY MANUFACTURER CATEGORY 5 10base -T UTP CABLE CAT4 ECHELON CAT 4 CABLE • — • - SINGLE CONDUCTOR THHN AS REQ. BY CODE #18 - • • - • • - • • - TWISTED, SHIELDED PAIR; TRANE APPROVED • • • - #18/3C WITH SHIELD CABLE; TRANE APPROVED TRANE - APPROVED COMMUNICATION WIRE AVAILABLE THROUGH CONNECT AIR 1- 800 - 247 -1978, WWW.CONNECT - AIR.COM WINDY CITY WIRE 1- 800 - 379 -1191, WWW.SMARTWIRE.COM NO SUBSTITUTIONS WILL BE ACCEPTED II!Ilr,_ - •• -, • - •• -.._ COMM, L NK 2 1 E -- F G - - - - - THERMOSTAT WIRING NOTE: LOCATIONS FOR REFERENCE ONLY! FOR EXACT LOCATIONS SEE MECH. DRAWINGS. - • • - • • - • • - BCU COMMUNICATION LINK NORTH I ' 0 Inch i 5 1 It l • 1/16 1 '1•I'I — r _l- b • 'r 1 11111111111111111111 1111111111111111111 1 - War" "rriV 1mT SECOND FLOOR COMMUNICATION TRUNK DIAGRAM RUN COMMUNICATION TRUNK TO ALL UNITS AND PANELS EXACTLY AS SHOWN OR VERIFY ALTERNATE ROUTING WITH TRANE. DRAWING SHOWN FOR REFERENCE ONLY. SEE MECHANICAL PLAN FOR ACTUAL LOCATION OF MECHANICAL EQUIPMENT. ryoYA- i 9 • i o IIIIIIIII I I III1IIIIIIIIII I I I I VIII ,1IIIIIIIIIIIIIIIIIIIIIIIIIII ►1111111111111111111111111 1� • 10 NOTE: * INDICATES REQUIRED LOCATION OF A 105 OHM RESISTOR ALONG THE CAT 4 COMMUNICATION LINK. 11 1z. • GJ 111 BCU -1 H COMM LINK 12 0 z w 0 a 0 z N CO 0 (O 0 0 N N N • BMS 4 OF 7 ■ N 0 CO N cV N O 0 L 0 z N j 70 • U(/) cy Omi y RI Q Q E te E cu E a) ONE, (1) 0N¢ ... -1a)h°14 /0000 U 1- 1 I I II�I � I � II .I.I.IuI. -. _ -.. I AC I24V GN GND 2 GND 3 GND 4 GN `` II\\ JJ POW R BINARY OUTPUTS STATUS LED I I„ ., I , I I I „1 • I Oil e� oil ill I ■ I„ - E Tracer MP503 r I ,. 503 -I SERVICE PIN LED DC OUT 24V 24V UNIVERSAL INPUTS I GND 2 /3110 /3110 3 GND 4 GND COMMS I C ON MS A U . A 4!D -- - - laiRIT tII I - I -1 I I I 1 I I I I I 1 1 1 1 I (o I , 0 f ... 00 Ilb 131 . _- _ I WIRING NOTES EXISTING OR FACTORY WIRING BY MANUFACTURER CATEGORY 5 10base —T UTP CABLE CAT4 ECHELON CAT 4 CABLE — • — • — • — SINGLE CONDUCTOR THHN AS REQ. BY CODE #18 — • • — • • — • • — TWISTED, SHIELDED PAIR; TRANE APPROVED — • • • — • • • — #18/3C WITH SHIELD CABLE; TRANE APPROVED TRANE — APPROVED COMMUNICATION WIRE AVAILABLE THROUGH CONNECT AIR 1- 800 - 247 -1978, WWW.CONNECT— AIR.COM WINDY CITY WIRE 1- 800 - 379 -1191, WWW.SMARTWIRE.COM NO SUBSTITUTIONS WILL BE ACCEPTED RELAY MOUNTE AHU -2 START /STOP RELAY SEE WIRING DETAILS ON BMS -7. RELAY MOUNTED AHU -I START /STOP RELAY SEE WIRING DETAILS ON BMS -7. CIRCUIT __ /__ 48o VAC SEE DETAILS ON BMS -7. I I - 0 Inch r • XFMR- �u� ( -1 MULTI - TAP. 96 V + a ISOLATED TRANSFORMER INSIDE AHU CONTORL PANEL. 9 Hh 14 Z- 13 INSIDE AHU CONTORL PANEL. 24 VAC - — AHU -I - C 0 - --------- - - - - -- -� STATUS RELAY (0 ° '�,- SEE AILS ON BMS -7. I SR -� AHU -I ' STATUS RELAY OL o °A --”; I ; ------- -- --- --- -- ---J AC -1 & AC -2 (MP503 -1) FIELD WIRING DETAILS (FIELD VERIFY MOUNTING LOCATION) 7 "W x 6 "H x 2 "D (175mm W x 161mm H x 51mm D) 5 105 Ohm RESISTOR IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIII IIIIIIIIIIIIIIIllll l llillliIiiii iiiiIilllilllllli11111111111 ,IIIIIIIII.ILIIIIIIIIIIII CAT4 — CAT4 — CAT4 FROM BCU -1 JUN 2 6 2003 COMMUNICATION LINK "1" t ?);'i.- -� lkh .�, -I 3 0 a 0 z I— U W 0 D. 0 Z N CV t0 0 0 • N 0 CO CNI O O V fh V c � CU OF; V) ui O n. u. C y 0 ca U 2 E CD Z N TS 0 N b 22 GI N^ S = E o E mo N-= cnU BMS 5 OF 7 \ • 1 I I 1 1213141 I� g i'rr. ADDRESS WA-a> SWITCH SW1 S W2-4:=)- 1 !OM NI' SEE ADDRESS V11-c:).- 4 55' 6 SETTING ON BMS -7 S. gj CONTROL BOARD V 0 5 TB4 CR�•1 KEEP SHIELD CONTINUOUS UNTIL LAST BOX ON THE DAISY -CHAIN THEN TAPE THE SHIELD BACK. - • . tw -RED BIP GND 24V - .-BR -1 - --♦ -BR NR FLOW SWITCH ELECTRIC HEATER CONTACTOR 2 ME ( ACTOR 1 -*-OR FAN MOTOR -+-B R RN RELAY FAN CONTROL BOX g 24 VAC (-) FACTORY WIRED TRANSFORMER --+ HOT FIELD WIRED ---6 OPEN DAMPER ---� CLOSE MOTOR PRESSURE VAV /UCM CONTROL BOX � WHT-�-+BLK- BLK +(HIGH) -(LOW) (FACTORY MOUNTED FLOW RING) �ATJ FACTORY WIRED HEATING AND FAN CONTACTORS. SEE MECHANICAL PLAN "M0.02" FOR ADDITIONAL INFORMATION. --LINE VAC 3 PHASE CIRCUIT __ /__ BY ELEC. CONTRACTOR POLY -TUBE DDC /VAV DISCHARGE TEMP 1. MOUNTED IN DISCHARGE AIR DUCT 1 ft. (12 in) ) AFTER VAV BOX. 2. SENSOR SUPPLIED WI /IMMERSION GROMMET. 3.TAPE BACK SHIELD. ZONE SENSOR; 1. (1) 18/3C CABLE WITH SHIELD REQUIRED. 2. SEE MECH. PLAN FOR EXACT LOCATION 3 TAPE BACK SHIELD. 4, MOUNT AT APPROVED HIEGHT. BCU -1 COMM LINK -2: DAISY CHAIN UNTIL LAST NEW VAV BOX. TYPICAL VAV BOX RETROFIT KIT WIRNG DETAIL (TYPICAL OF 18 VAV BOXES) WIRING NOTES EXISTING OR FACTORY WIRING BY MANUFACTURER CATEGORY 5 10base —T UTP CABLE CAT4 ECHELON CAT 4 CABLE — • — • —•— SINGLE CONDUCTOR THHN AS REQ. BY CODE #18 — • • — • • — • • — TWISTED, SHIELDED PAIR; TRANE APPROVED • • • — #18/3C WITH SHIELD CABLE; TRANE APPROVED TRANE — APPROVED COMMUNICATION WIRE AVAILABLE THROUGH CONNECT AIR 1- 800 - 247 -1978, WWW.CONNECT — AIR.COM WINDY CITY WIRE 1- 800 - 379 -1191, WWW.SMARTWIRE.COM NO SUBSTITUTIONS WILL BE ACCEPTED ADDRESS W4 -a- SWITCH SW1 ® W2 -a- I����I SEE ADDRESS W1-c=)- SETTING ON BMS -7 WW =j I1 121314151 8 CONTROL BOARD 0 KEEP SHIELD CONTINUOUS UNTIL LAST BOX ON THE DAISY -CHAIN THEN TAPE THE SHIELD BACK. TYPICAL I �...__...__� l • t a .0 ill, -__ L �__ �.._ �IIIIIIIIIIIIIIIIIIIIIIII�IIIIIIIIILIIIIIIIII II lllll�lll II I111�1111IIII1III llllll, 1lllllllll1llllllllllll ,IIIIIIIIIIIILIIIIII VAV INSTALLATION NOTES: 1. KEEP COMMUNICATION TRUNK SHIELD CONTINUOUS UNTIL THE LAST UNIT ON THE LINK. 2. TAPE BACK COMMUNICATION TRUNK SHIELD AT LAST UNIT ON COMMUNICATION LINK. 3. ALL TERMINATIONS ARE STANDARD 1/4" STAB ON CONNECTORS. 4. SET VAV /UCM ADDRESS AT "S1" ON UCM CARD AS SHOWN. TB4 BIP GND 24V L (STAX 2 !' ACTOR 1 (SITE 1) --0 -BR 1 — +-- BR -C�o-- AJR FLOW SWITCH ELECTRIC HEATER FAN MOTOR ---S BRN RELAY FAN CONTROL BOX 24 VAC (-) ( + ) iII C FA WIRED TRANSFORMER FACTORY WIRED DAMPER MOTOR PRESSURE TRANSDUCER VAV /UCM CONTROL BOX BCU -1 COMM LINK -2: DAISY CHAIN UNTIL LAST NEW VAV BOX. VAV TERMINAL BOX (TYPICAL OF 13 VAV II o h:"'41 • • +(HIGH) -(LOW) (FACTORY MOUNTED FLOW RING) FACTORY WIRED HEATING AND FAN CONTACTORS. SEE MECHANICAL PLAN "M0.02" FOR ADDITIONAL INFORMATION. — LINE VAC 3 PHASE CIRCUIT BY ELEC. CONTRACTOR , :Ps TO I DEC 9 C CITY (: i= T U K'v\ ILA F3 r i- 1 , ; DDC /VAV DISCHARGE TEMP i.MOUNTED IN DISCHARGE AIR DUCT 1ft. (12 in) AFTER VAV BOX. 2.SENSOR SUPPLIED WI /IMMERSION GROMMET. 3.TAPE BACK SHIELD. ZONE SENSOR: 1. (1) 18/3C CABLE WITH SHIELD REQUIRED. 2. SEE MECH. PLAN FOR EXACT LOCATION 3 , TAPE BACK SHIELD. 4, MOUNT AT APPROVED HIEGHT. CONTROLLER DETAIL BOXES) 1 0 0 Z 0 c0 N co 0 Co 0 0 0 N N • cV o oq ao 0 au. N y O O rn m a W C (1), N> o O Of a� CC 3 e k 0 M BMS 6 OF 7 TERMINAL # I w J UN # DIP SWI UNIT ADDRESS SUMMIT ADDRESS 1 1 23 456 VAV -1 1 2 toeeses 1 65 VAV -2 1 2 SHIM] 2 66 VAV -3 1 2 tooeeee 3 67 VAV -4 1 2 teeoeee 4 68 VAV -5 1 2 toeoeee 5 69 VAV -6 1 1 2 2 01510110 t ail oMOO 6 7 70 71 VAV -7 VAV -8 1 2 teeeoee 8 72 VAV -9 1 2 toeeoeO 9 73 VAV -10 1 2 teoeoee 10 74 VAV -11 1 2 tWOeoee 11 75 VAV -12 1 2 trilnWHI 12 76 VAV -13 1 2 tQeQQee 13 77 VAV -14 1 2 CHIME 14 78 VAV -15 1 2 tQQQQee 15 79 VAV -16 1 2 teeeeoe 16 80 VAV - 17 1 2 'MHO 17 81 VAV - 18 1 2 teoeeoe 18 82 VAV -19 1 2 tiloeeoe 19 83 VAV -20 1 2 teeoeoe 20 84 VAV -21 1 2 toeoeoe 21 85 VAV -22 1 2 teooeoe 22 86 VAV -23 1 2 tQQQeQe 23 87 VAV -24 2 Ol ti n i e 24 88 VAV -25 2 toeeooe 25 89 VAV -26 1 2 teoeooe 26 90 VAV - 27 1 2 fWWIHWE 27 91 VAV -28 1 2 tee000e 28 92 VAV -29 1 2 tQ Mil QQe 29 93 VAV -30 1 2 t e OI D o e 30 94 VAV - 31 1 2 tooWW 31 95 -- — — teeeeeo 32 96 -- — — toeeeeo 33 97 -- — — — — teoeeeo tooeeeo 34 35 98 99 -- -- — — teeoeeo 36 100 -- — — toeoeeo 37 101 -- — — teooeeo 38 102 -- — — t000eeo 39 103 -- — — teeeoeo 40 104 -- — — faNIIIIN 41 105 -- — — t!QNW 42 106 -; -- — — — — tooeoeo t ! rill U rip 43 (;li1 44 1 ,108_, -- -- — — toeooeo 45 '1'09 - -- — — te000eo 46 110 -- — — t0000eo 47 1:, -- — — — — teeeeoo Ohl a e ' o 48 0 49 112 113 -- -- — — teoeeoo 50 114 -- -- — — — tQQeewQ 51 115 — teeoeoo 52 116 -- — — — toeoeoo 53 117 -- — teooeoo 54 118 -- -- - - __ -- — — — — t000eoo teee000 55 56 119 120 -- — — tQeeOQQ 57 121 -- — — teoe000 58 122 -- — — - tQQeQQQ fee0000 59 60 123 124 __ — -- — — — - tQeQQQQ teQQQQQ 61 62 _ 125 1 26 _ 127 -- -- — — fQQQQQQ 63 TO MP503 -I A1-1U -1 = BOP #1 AHU -2 = BOP #2 SEE BMS -5 FOR DETAILS. R -I RELAY MOUNTED INSIDE AHU CONTORL PANEL. a � 14 13 TO MP503 -1 .---- - - - - -- AHU-1 = IN #1 AHU -2 = IN #2 SEE BMS -5 FOR DETAILS. I • 0 Inch WIRING NOTES EXISTING OR FACTORY WIRING BY MANUFACTURER CATEGORY 5 10base —T UTP CABLE CAT4 ECHELON CAT 4 CABLE -- • — • — • — SINGLE CONDUCTOR THHN AS REQ. BY CODE #18 — • • — • • — • • — TWISTED, SHIELDED PAIR; TRANE APPROVED — • • • — • • • — #18/3C WITH SHIELD CABLE; TRANE APPROVED TRANE — APPROVED COMMUNICATION WIRE AVAILABLE THROUGH CONNECT AIR 1-800-247-1978, WWW.CONNECT — AIR.COM WINDY CITY WIRE 1- 800 - 379 -1191, WWW.SMARTWIRE.COM NO SUBSTITUTIONS WILL BE ACCEPTED NOTE: HOA, STARTER AND /OR DISCONNECT BY OTHERS, OFF NAND � AUTO F T - -- AUTO -� u - 1 a 1 i CSR -I wlrr— CURENT SENSING RELAY MOUNTED ON LINE VOLTAGE LEG "1". AHU -1 & AHU -2 FIELD WIRING DETAILS 460VAC BY DIV. 16 ELECT. CONTRACTOR r -1 L1 L2 L3 I....1.....L....I EOUIP GROUND I 7 i A r �IIli�lllllllll�llll IIIIiiiIII I IliI. IIIIII�III� IIIIIIIII�I�. III111 JIIIII�IIII�IIIIIIIII�IIII FMI J L l 0 IIII,1IIII1W IIIIIII�IIIIIIIII �IIIIIIIII�IIIIIIIIIIIII I TUKW1 , ) r VA .8 P co 0 I a z 0 w 0 IL a , 0 Z o C ■ rci Tr Tr ox a U. N O co O 0 • (V BMS 7 OF 7 • FLOOR PLAN REVISIONS BOX ADDRESSING > 'TITLE: VAV TERMINAL DRAWN BY: DLS BOM UPDATE DESCRIPTION