Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M01-017 - MICROSOFT
City of Tukwila T (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Address: 12101 TUKWILA INTERNATIONAL BL Location: 4TH FLOOR Parcel ##: 092304 -9031 Contractor License No: TENANT MECHANICAL PERMIT Permit No: M01 -017 Status: ISSUED Tvoe: B -MECH Issued: 02/08/2001 Category: NRES Expires: 08/07/2001 MICROSOFT 12101 TUKWILA.INT'L. BL. TUKWILA, WA 98188 OWNER SABEY DAVID A & SANDRA L 101 ELLIOTT AV W #330. SEATTLE WA 98119 . CONTACT WAYNE CORNELL 1221 2 AV N, KENT, WA 98032 CONTRACTOR HERMANSON CO. LLP 1221 2ND AVE N, KENT. WA 98032 98032 **,****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALL MEDIUM PRESSURE TRUNK,. INSTALL (8) VAV BOXES, 8" SQUEEZE BOX, AND_ INSTALL ASSOCIATED DUCT WORK. Phone: Phone: (206)000 -0000 Phone: 206 - 575 -9700 Phone: 206 - 575 -9700 AMC Edition: 1997 Valuation: '43,199.00 Total Permit Fee: 78.19 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** o Permit` Center. Aut ized'Signature Date I. hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this . permit does not presume to Give authority to violate or cancel the provisions of any other state or local laws regulating construction or . the performance of work. I. am authorized to sign for and obtain this building permit. Signature: �! 1 -\ Date: Z =af- Print Name.___ _1') /U LC //)- Title: This permit shall become null and void if the work is not commenced within .;.180 days from.the date of issuance_, or if the work is suspended or - abandoned for a period of 180 days from the last inspection. z w cc 2 00 (na CD ILI u .. wO g Q w' z i ` H O '. M O N . O H' w . II- ~ O w z . U =, O ~ + z DEPARTMENTS: Buil ing Division W/, 2-40 Public Works PERMIT COORDzpy PLAN REVIEW/ROUTING SLIP 'ACTIVITY NUMBER:. M01-017 DATE: 1-29-01 PROJECT NAME: MICROSOFT 4569 — FLOOR 4 SITE ADDRESS: 12101 TUKWILA INT'L. BL SUITE NO: XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1 Incomplete n TUES/THURS ROUTING: Please Route Structural Review Required APPROVALS OR CORRECTIONS: (ten days) Y'RROtIlLOCIC SAM Fire Prevention X1 Structural n Planning Division Permit Coordinator DUE DATE: 1-30-2001 Not Applicable ri Comments: No further Review Required n REVIEWER'S INITIALS: DATE: DUE DATE 2-27-2001 Approved ri Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: DUE DATE CORRECTION DETERMINATION: Approved ri Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: F iiiiirraltiligswescoovorg PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M01 -017 PROJECT NAME: MICROSOFT 4569 - FLOOR 4 XX Original Plan Submittal DATE: 1 -29 -01 SITE ADDRESS: 12101 TUKWILA INT'L. BL SUITE NO: Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES /THURS ROUTING: Incomplete n Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved VMtMOUI (.000 REVIEWER'S INITIALS: Approved ith Conditions 6- CORRECTION DETERMINATION: Approved Approved with Conditions n REVIEWER'S INITIALS: n Planning Division Permit Coordinator DUE DATE: 1-30 -2001 Not Applicable n No further Revie Requir DATE: n DUE DATE 2- 27-2001 Not Approved (attach c mments) DATE: DUE DATE Not Approved (attach comments) DATE: 7 w c qg 00 (00: u� w • u.: w O' gQ , O W 11J a v • O N CI ff w Z lii O Z • • PERMIT NO.: .MD I OI7 MECHANICAL PERMIT APPLICATIONS INSPECTIONS 00002 Pre - construction 00050 WSEC Residential 00060 WA Ventilation/Indoor AQC 00610 Chimney Installation/All Types 00700 Framing 01080 Woodstove 01090 Smoke Detector Shut Off 01100 Rough -in Mechanical 01101 Mechanical Equipment/Controls 01102 Mechanical Pip/Duct Insul ❑ 01105 Underground Mech Rough -in ❑ 01115 Motor Inspection 1400 Fire Final 01800 Final Mechanical 04015 Special -Smoke Control System CONDITIONS 0001 No changes to plans unless approved by Bldg Div ❑ 0014 Readily accessible access to roof mounted equipment 0016 Exposed insulation backing material 0019 All construction to be done in conformance w /approved plans ❑ 0002 Plumbing permits shall be obtained through King Co 0027 Validity of Permit 0003 Electrical permits obtained through L & I 0036 Manufacturers installation instructions required on site ❑ "BTU maximum allowed per 1997 WA State Energy Code" ❑ 0041 Ventilation is required for all new rooms & spaces ❑ "Fuel burning appliances ❑ "Appliances, which generate...." "Water heater shall be anchored...." Additional Conditions: TENANT NAME: `FEES cso4 4stol flaw 1 Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace/Burner • to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor - mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm/Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter S$) Add'! Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'l Plan Review (hrs) Plan Reviewe Permit Tech: Date: Date: DEPARTMENTS: Building Division Public Works Y'RROUIL.00C srfl PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M01 -017 DATE: 1 -29 -01 PROJECT NAME: MICROSOFT 4569 — FLOOR 4 SITE ADDRESS: 12101 TUKWILA INT'L. BL SUITE NO: XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued APPROVALS OR CORRECTIONS: (ten days) Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 1-30-2001 Complete I Incomplete n Comments: TUES /THURS ROUTING: Please Route Ti Structural Review Required REVIEWER'S INITIALS: Approved n Approved with Conditions n n CORRECTION DETERMINATION: Approved n Approved with Conditions n REVIEWER'S INITIALS: r Planning Division Permit Coordinator No further Review Required DATE: /p e /e Not Approved (attach comments) n Not Applicable n DUE DATE 2-27 -2001 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: DUE DATE I I DATE: z W • • re f, U; 00. p. ww � LL; W O: J, LL <. w' • z 0 0: W W: O. . z r~- _ .O f- J Z Project Name/Tenant: , �iiGro -('-� W5�� bon---r-0}— Flvoty Value of Mech ical E 'pent: ') / T/ , Site Address : � - -- 11, 01 I u. kwl /A . city t te2ip All i . �' lUl �tt. Tax P Numbef• U 9( � - ittaq' Property Owner: / ff' Ir, y'o � 1 by o City/St 1,0 D � I -� 4 S Phone: ( ) Street Address: City State/Zip: Fax #: ( ) Contractor: 11,6* `C / j LLP Phone: ( 7 ) - 1, ) C-S � 7 Street Address: � L , L I z �� N. p iiAti ta3g y 1 , Fax #: b .�, ) ._ tr Contact Person:. in 8,11 Co +` I Phone : . ( /5 . 1,, ) s ... 7 s Street Address: (17. ► 1 1\11) M N • City t it K imi- � o Fax #: ( ) Zola 57 S -- gC BUILDING • NER OR AUTHO ' IZED AGENT: Signature: ` i Ili Date: ..N,Oi Print na . e: /1 A pkan 1 fr (C A 2--- P hone: (20L � \ / \• _ 20L V -7� 17� Fax : ) F # 5")s- .C7c�l�) Address: 2 . 7 .a►�/Iip;,� ( 7 N NC ) City/St 1,0 D � I -� 4 S Mechanical Permit Application f I /2/99 ntecb perntil.doc CITY OF It ..•WILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 t Project Numbe Permit Number. STAI I USf ONI Y Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Descri n of rk to be done (please be specific): � r wo ll m l l ip itSSu l'U UM k 1 1 n5 s) \/P'V' Do)(t6 ( • SG kit IL boc 1119-et a 550G of ed abc. ±f Loo KL, Current copy of Washington State Department of Labor and Industries Valid Contractor's license. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LA WS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: 1 2q -0 Date application expires: O I Application taken by: (initials) ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal ESIDENTIALr Two complete sets of attachments required with application submittal Submittal Requirements New Sin le Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change - out or replacement of existing mechanical equipment Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition: NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. a. W; �, r Address.' 11210f Tlf L� INTERNATIONAL BL Permit No: M01 -017 ,Suite: Tenant MICROSOFT `,a_ • Status: ISSUED Type: B-MECH Applied: 01/29/2001 Parcel : #: 092304-9031 Issued: 02/08/2001 ** k.********** k***** �4******• k A******• k****• k• k*• k * * *** *•k*k *•AA**AA * * **•k•k * *•k k P ermit ,Conditions: 1.. No`'.changes will be Made to the plans unless approved by the Engineer anddthe Tukwila Building Division. 2. .All permits, i nsp'ect i on pre ;• cords • and "` approved plans shall be available at the ,j ob " sate'`pri or to the 'start %of any con - struction. The•se;d a're to`.be . mainta'ined, and avai 1 able until final ` ;approva'l is granted 3 s All construction l to. 'be doe ,'i n' conformance w th. approved plans "and ' 1 reme'rits of the ,Uniform Bu i 1 di n9 Code' (,1997 Ed,1tion)4tas amended, Un:,iform Mechani cal= °Code' (199 Edition) a nd Washrington. State Energy `Codas`. ,,(`1 Edition) 4> Val i d ittAt nf Permit The issuance of a permit oi. • of p 1_ans,. {;peci.f icat,ions, and..computations shall not , :66:;._ • , ,con • ti st:ruedr bye a'•per.mi t f.or, Or an, approval of, any violation nF ati` of t'he. provisions of' ‘the 'building code or `got , any the 4 h or or,?dinence of: t,he.,�jur lsdicti No permit presuming: to g i,vef,aut;hor..ity : violate ar ;cancel the provisions ot�l,thi's x co de ;shall; `be valid. '' Y s y ,' 1 0 ' � r. t \ ,LI r •i I h` ereb d � y certify that I have. t hese conditions and will c omps v ', w4i them as outl ined , : ALL., of. l and ordina ;.gave t w i7 will be compl iced `iith, .,Whether •specified herein or not. • T grari, , ing,of this permit ` does not ` give authority to vi °orr cancel the provisions n ions of ' any ,,ot word' or Local laws` regulati.rrgr , .construct'ion or the performance, of. work. . , ; ' ` S.i;gnature ,� f 0r1 t' N a lire t • CITY OF TUKWILA ate: z h e lW o o , � w w o'. II ; w z, U N Ham, z *k* * * * **: * * ** 4** * 4*k*k***k* **** ** k *• ** * ** k* * k *** **t* ** *** ITY .AF TtiKW1L 1�1H / TREfrr.a1,11 i. * •l Irk * * *** *k* ****** *stir * ****•k*k ** *** **k** *k***1 ** ** * ** ** **•k* TkAt1SMII iluinb R01* „U163 Amoutnt 78.19 02 /O8 /Oi. 09 :2, (' anrment r Method • r •. -CHECK Uotation: HERIJANSON , CO 'tilt: KDJ` P u nit, No 140 1,-()3.7: MECHANICAL PERMIT F}iii^ce1'' •092.64- -9031 Site Addiess: 12101 I;UKWILA INTERtIATIDNAL L a0atian: :;4TH: FLOOk Total Faes» P ayment; 7.819 : T otal ALL ;P.mt;ao. `78 1 "d • B lance :nt) **:* kk******** IV* *. k* * *' * ** * * *** ** * * *it* * * * * * *sl ** *c** * *•k * ;.:De is r: `obion PLAN CHECK . NONRES MECHANICAL -- , NONRES '. Project://fr 51) ff 7 e&1 spe tion: / V C Address: Special instructions: 04 do ..- -- . ( Q 1 "' � D -1 5. w rp a t/ .; — 9/5— 76 Y ' Date wanted: 3 9 10 a.m. Re. R er: Phone: gv6 - 37G , - /%s INSPECTION RECOR.. Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. PERMIT NO. (206)431 -3670 COMMENTS: Corrections required prior to approval. /t- Date 7 —'6) / $47.OI REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Project: A IGrbSt l Type of.Insp cti n vV' a&c - f7ti d- rt 0 Address: / ( 0. 144 A (r / D c l , � Special instructions: Datey�ante c2- 0 570/ (.m) p.m. Re gyester: V/ vim Phone: INSPECTION RECD( - ( Retain a copy with.permit IiT OF TUKWILA BUILDING DIVISION 300 Southcenter Blvd, #100, Tukwila, WA 98188 INSPECTION NO. Approved per applicable codes. MD2 -D "7 PERMIT NO. (206)431 -3670 COMMENTS: �4 p (A. 1 ti e. Inspector: D a te :2 2'3 r b Corrections required prior to approval. $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Proje t: + G 7 ` i, 62> Type of Inspecti e • Ad ress: f ) 2 40 / / / 4 if ate call d: ° Special instructions: Date wanted: // �aP ,...� l(o — 0/ p.m. Reques Phone: Approved per applicable codes. INSPECTION RECO( Retain a copy with permit INSPECTION NO. e, OF TUKWILA BUILDING DIVISION 300 Southcenter Blvd, #100, Tukwila, WA 981 it • or o, PERMIT NO. (206)431 -367 Corrections required prior to approval. COMMENTS: 7(; i7 s,.l,G Date: $47.00 REINSPECTION f E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Project Info Project Address Tukwila Intergate West Building No. Date 1/24/01 12101 Tukwila international Blvd. For Building Department Use Tukwila, WA Applicant Name: Wayne Cornell - Hermanson Company Applicant Address: 1221 2nd Ave N, Kent, WA 98032 Applicant Phone: (425) 705 -3550 1997 Washington State Nonresidential Energy Code Compliance Forms 1997 Wa in ton State Nonresidential Ener. Code Comjnce Form Envelope Summary. Climate Zone ENV -SUM RECEIVED CITY OF TUICWILA JAN 2 g 2001 .PERMIT CENTER Mop -or! First Edition - June, 1998 Fan Equipment Schedule Equip. • ID Brand Name Model No. CFM SP' HP /BHP Flow Control Location of Service VAV- TBD1 Titue DTQS -03 960 0.50 0.25 N/A FLR 4 VAV- TBD2 Titus DTQS -03 800 0.50 0.25 N/A FLR 4 VAV- TBD3 Titua DTQS -03 800 0.50 0.25 N/A FLR 4 VAV- TBD4 Titus DTQS -03 1200 0.50 0.25 N/A FLR 4 VAV- TBDS Trane VCCE -08 1200 0.50 N/A N/A FLR 4 Project Info Project Address Tukwila Intergate West Building •c• Date 1/24/01 Capacity Btu /h 12101 Tukwila International Blvd. For Building Dept. Use SEER or EER Tukwila, WA Applicant Name: Wayne Cornell - Hermaneon Company Applicant Address: 1221 2nd Ave N, Kent, WA 98032 Applicant Phone: (425) 705 -3550 Cooling Equipment Schedule Equip. ID Brand Name Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location AC -TBD1 Trans TCD036C 37400 1200 300 10.00 N/A FLR 4 Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency NONE 4 • f S 1997 Washington State Nonresidential Energy Code Compliance Forms 1997 WaAbington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM First Edition • June, 1998 Project Description I Briefly describe mechanical system type and features. Compliance Option O Simple System *Complex System O Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. applicable. 2 As tested according to Table 14 -1, 14 -2 or 14 -3. 3 1f required. ' COP, HSPF, Combustion Efficiency, or AFUE, as 4 • H W C) cop , ' NWr u WO u-< ` W a 1 ILI 2 j D O N tL W W ti Z N . Z System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? fl Split system? j Air cooled? Packaged sys? E Economizer included? <54,000 Btuh or 1900 cfm? If Heating Only: <5000 cfm? <70% outside air? 1997 Waa ington State Nonresidential Energy Code ComgUa[tce Form Mechanical Summary (back) MECH -SUM Heating Only System Type • Cooling Cooling Only no Reference Sec. 1421 <70%0A Econo Included? ,000 Btuh 1900 dm? • nstant olume? Split em? Reference 54,000 Btuh Sec. 1423 • 1900 dm? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. or ti yes Simple System Allowed C Referenoe Sea 1420 / no r Use Complex Reference System Sea 1430 Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Project Info Project Address Tukwila Intergate West Building •C• Date 1/24/01 CFM 12101 Tukwila International Blvd. For Building Dept. Use Flow Control Tukwila, WA Applicant Name: Wayne Cornell - Hermaneon Company Applicant Address: 1221 2nd Ave N, Kent, WA 98032 Applicant Phone: (425) 705 -3550 Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SP' HP /BHP Flow Control Location of Service Location Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency' 1997 Way ington State Nonresidential Energy Code Compti-nce Form Mechanical Summary MECH -SUM , 1997 Washington State Nonresidential Energy Code Compliance Forms First Edition - June, 1998 Project Description Briefly describe mechanical system type and features. Compliance Option 0 Simple System ® Complex System O Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 1 1f available. 2 As tested accord ng to Table 14 -1, 14 -2 or 14 -3. 3 If equired. " COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? Split system? Air cooled? fl Packaged sys? Economizer included? <54,000 Btuh or 1900 cfm? If Heating Only: fl <5000 cfm? <70% outside air? • 1997 Waiington State Nonresidential Energy Code Compce Form Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. ting/Cooli or Cooling Only no Reference ` Sea 1421 no Econo Included? yes Constant Volume? yes . yes no 4 Simple System Allowed • Reference Sea 1420 no Reference / <54 ,000 Btuh Sea 1423) C or1900 cfm? no r Use Complex Reference System Sec. 1430 Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical - Compl- 1997 Washington State Nonresidential Energy Code Compliance Forms Systems Checklist MECH -COMP First Edition • June, 1998 Project Address Tukwila Intergate West Building "C" Date 1/24/01 The following additional Information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH- CHK checklist for additional system requirements). This Information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY n.a. 1431.1 Field assem. sys. (Provide calculations I I 1432 Controls • n.a. 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans I 1432.2 Temp. reset control n.a. 1432.2.1 Air systems Indicate automatic reset n.a. 1432.2.2 Hydronic systems Indicate automatic reset n.a. 1433 Economizers Indicate economizer on equipment schedule or provide calculations to justify exemption n.a. 1434 Separate air sys. Indicate separate systems on plans n.a. 1435 Simul. htg. & clg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified Other n.a. 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations n.a. 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency n.a. 1438 Variable flow sys. Indicate variable flow on fan and pump schedules 1997 Way ington State Nonresidential Energy Code Complaapce Form Capacity ofI1W Hating System Gana Than 600,000 Iltuh? Satins 1432:2 Rot \ Vista Supply Tanpanae Reset Controls Required Sadon 1432.2.1 Supply Air Resct Controls Raluinil no is circled for any question, provide explanation: Decision Flowchart requirements. (Stall) Section 1411.1 [quipman red Shall Mat Tables 14 -I through 14-3 i Satlon 1431.1 Calculations of Total On -site Stagy Input & Output Required (continued on back) MECH -COMP Mechanical - Compl Systems (back) 1997 Washington State Nonresidential Energy Code Compliance Forms 1997 W ,ington State Nonresidential Energy Code Comp ce Form Cooling Capacity> 20,000 Btuh? Supply Air> 5000 CFM & Outside Air > 70%? Applicati on Involves Variable F lows' Electric Motor Efficiency Included in Equipment Performance Rating? Heating Type > 225,000 Stull Capacity? Fans or Pumps > 10 HP? Mutt i- speal Motor in a Multi -s peed Systan? VAV Systan? otal Bldg Capacity> 240,000 Btuh . r 10 %of tots Section 1411.4 Must be Hat Pump 1412.5 Provide Micropnrccssor Hal Pump Controls Non - Electric Section 1433 Air-Side Economizer Required Section 1435 Fan Powered Terminal Units Required Section 1438 Variable Flow Devices Required (continued from front) ectric Section 1412.6 Modulating or Staged Combustion Controls Required Section 1436 50% Effective Hat Recovery Syrian Requiled Section 1435 Sintultancous Hating & Cooling Prohibited Section 1437 Motors Must Mat Effici ncies in Toll 14.4 First Edition • June, 1998 0 Open Motors Closed Motors 3,600 1,800 1,200 3,600 1,800 1,200 Efficiency ( %) Efficiency ( %) - 82.5 80.0 75.5 82.5 80.0 82.5 84.0 84.0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 87.5 87.5 87.5 88.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 89.5 _ 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 92.4 91.7 91.0 92.4 92.4 91.0 92.4 91.7 91.7 93.0 93.0 91.7 93.0 93.0 92.4 93.0 93.0 92.4 93.0 93.0 93.0 93.6 93.6 93.0 93.6 93.6 93.0 94.1 93.6 93.0 94.1 93.6 93.0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 93.6 95.0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 95.0 95.0 95.0 • 1997 W cline ton State Nonresidential Ener• Code Com .mice Form Electric Motors 41 11 MECH -MOT 1997 Washington State Nonresidential Energy Code Compliance Forms Pro1ect Address Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired (unless one of the exceptions below applies). N/A Motor No. or Location Minimum Nominal Full -Load Efficienc Synchronous Speed (RPM) HP 1.0 1.5 2.0 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 HP Tukwila Intergate West Building "C" Type (open /closed) Description of Application or Use Date For Building Department Use Synch. Speed First Edition - June, 1998 1/24/01 Min.Nom. Full load Efficiency Exceptions: 1. Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- 1 or 14 -2). 3. Motors that are an integral part (i.e. not easily removed and replaced of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment is with a less- efficient motor and there is no energy- efficient motor option). For motors claiming an exception, list motor and note which exception applies. Mechanical Permit Plans Checklist MECH -CHK 1997 Washington State Nonresidential Energy Code Compliance Forms First Edition - June, 1998 Project Address Tukwila Intergate West Building "Co 'Date 1/24/01 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability I Code (yes, no, n.a.) Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule n.a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans MD01 n.a. 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat n.a. 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types n.e. 1412.4.1 Dampers Indicate damper location and automatic controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n. a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans MD01 n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans yes 1423 Economizers Equipment schedule 10101 1413 Air economizers n.a. 1413.1 Operation Indicate 100% capability on schedule n.a. 1413.2 Control Indicate controls able to evaluate outside air n.a. 1413.3 Integrated operation Indicate capability for partial cooling 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary MD01 yes 1414.2 Duct insulation Indicate R -value of insulation on duct MD01 yes 1415.1 Piping insulation Indicate R -value of insulation on piping MD01 n.a. 1424 Separate air sys. Indicate separate systems on plans yes Mech. Sum. Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer rim0i SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. n.a. 1441 Elec. water heater Indicate R -10 insulation under tank n.a. 1442 Shut -off controls Indicate automatic shut -off 1450 Heated pools 1452 (reserved) n. 1453 Pool heater controls Indicate switch and 65 degree control n. a . 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover no is circles for any question, provide explanation: 1997 W, kington State Nonresidential Energy Code CompllizRce Form t � a v0 co 0 =' N iL W 0 . tn a. W F 0 Z I— U0 0 — ID )_ : W W' I-- � O Z 1997 W^ gington State Nonresidential Energy Code Compl'^nce Form Mechanical Permit Plans Checklist MECH -CHK 1997 Wash„7gton State Nonresidential Energy Code Compliance Forms First Edition -June, 1998 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1 through 14-3. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water he applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 141t4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by indMdual thermostatic controls responding to temperature within the zone. At a minimum, each floor d a building shall be considered as a separate zone. 1412.2 Dsadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable d a deadband of at least 5 degrees F within which the supply d heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, If in the proposed building energy analysis, healing and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F Inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off : HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use d the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpolnt. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual df -hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets' serving conditioned spaces shall be equipped with dampers which close automatically when the system is off cr upon power failure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start -up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. 1413.2 Control: Air economizers shall be controlled by a control system capable d determining if outside air can meet part or all of the building's cooling loads. 1413.3 Integrated Operation: Building Heating Energy: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling Is required to meet the remainder of the cooling load. Controls shall not preclude the economizer oper ation when mechanical cooling is required simultaneously. Exception: Economizers on individual, direct expansion, cooling systems with capacities not greater than 75,000 Btu /h may include controls that limit simultaneous operation of the economizer and mechanical cooling for the purpose of preventing Ice formation on cooling coils. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent d sealing required is as follows: 1. Static pressure 1/2 inch to 2 Inches; seal transverse Joints. 2. Static pressure 2 inches to3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transversejoints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements d Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating surfaces to a minimum o f R -11 and any exterior envelope surfaces per Chapter 13. Outside air duct runs are considered building envelope until they, a. connect to the heating or cooling equipment, or b. are isolated from the exterior with an automatic shut-cif damper Once outside air ducts meet the above listed requirements, any runs within conditioned space must comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5, Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a space that serves that space only. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be Insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1420 SIMPLE SYSTEMS (PACKAGED UNITARY EQUIPMENT) 1421 System Type: To qualify as a simple system, systems shall be one of the following: 1. Air cooled, constant volume packaged equipment, which provide heating, cooling or both, and require only external connection to duct work and energy services. 2. Air cooled, constant volume split systems, which provide heating, cooling or both, with cooling capacity of 84,000 Btu /h or less. 3. Heating only systems which have a capacity d less than 5,000 cfm or which have a minimum outside air supply of less than 70 percent of the total air circulation. All other systems shall comply with Sections 1430 through 1438. 1422 Controls: In addition to the control requirements in Section 1412, where separate heating and cooling equipment serve the same temperature zone, thermostats shall be Interlocked to prevent simultaneous heating and cooling. Systems which provide heating and cooling simultaneously to a zone are prohibited. 1423 Economizers: Economizers meeting the requirements of Section 1413 shall be installed on single package unitary fan - cooling units having a supply capacity of greater than 1,900 cfm or a total cooling capacity greater than 54,000 Btu /h. The total capacity of all units without economizers shall not exceed 240,000 Btu/h per building, or 10% of Its aggregate cooling (economizer) capacity, whichever is greater. 1424 Separate Air Distribution Systems: Zones with special process temperature requirements and /or humidity requirements shall be served by separate air distribution systems from those serving zones requiring only comfort conditions. to 0 NW W g co _ - W UJ U� ON ca W U Z W = . Z EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 1997 W^ gington State Nonresidential Energy Code Compl'^nce Form Mechanical Permit Plans Checklist MECH -CHK 1997 Wash„7gton State Nonresidential Energy Code Compliance Forms First Edition -June, 1998 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1 through 14-3. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water he applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 141t4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by indMdual thermostatic controls responding to temperature within the zone. At a minimum, each floor d a building shall be considered as a separate zone. 1412.2 Dsadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable d a deadband of at least 5 degrees F within which the supply d heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, If in the proposed building energy analysis, healing and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F Inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off : HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use d the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpolnt. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual df -hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets' serving conditioned spaces shall be equipped with dampers which close automatically when the system is off cr upon power failure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start -up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. 1413.2 Control: Air economizers shall be controlled by a control system capable d determining if outside air can meet part or all of the building's cooling loads. 1413.3 Integrated Operation: Building Heating Energy: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling Is required to meet the remainder of the cooling load. Controls shall not preclude the economizer oper ation when mechanical cooling is required simultaneously. Exception: Economizers on individual, direct expansion, cooling systems with capacities not greater than 75,000 Btu /h may include controls that limit simultaneous operation of the economizer and mechanical cooling for the purpose of preventing Ice formation on cooling coils. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent d sealing required is as follows: 1. Static pressure 1/2 inch to 2 Inches; seal transverse Joints. 2. Static pressure 2 inches to3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transversejoints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements d Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating surfaces to a minimum o f R -11 and any exterior envelope surfaces per Chapter 13. Outside air duct runs are considered building envelope until they, a. connect to the heating or cooling equipment, or b. are isolated from the exterior with an automatic shut-cif damper Once outside air ducts meet the above listed requirements, any runs within conditioned space must comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5, Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a space that serves that space only. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be Insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1420 SIMPLE SYSTEMS (PACKAGED UNITARY EQUIPMENT) 1421 System Type: To qualify as a simple system, systems shall be one of the following: 1. Air cooled, constant volume packaged equipment, which provide heating, cooling or both, and require only external connection to duct work and energy services. 2. Air cooled, constant volume split systems, which provide heating, cooling or both, with cooling capacity of 84,000 Btu /h or less. 3. Heating only systems which have a capacity d less than 5,000 cfm or which have a minimum outside air supply of less than 70 percent of the total air circulation. All other systems shall comply with Sections 1430 through 1438. 1422 Controls: In addition to the control requirements in Section 1412, where separate heating and cooling equipment serve the same temperature zone, thermostats shall be Interlocked to prevent simultaneous heating and cooling. Systems which provide heating and cooling simultaneously to a zone are prohibited. 1423 Economizers: Economizers meeting the requirements of Section 1413 shall be installed on single package unitary fan - cooling units having a supply capacity of greater than 1,900 cfm or a total cooling capacity greater than 54,000 Btu /h. The total capacity of all units without economizers shall not exceed 240,000 Btu/h per building, or 10% of Its aggregate cooling (economizer) capacity, whichever is greater. 1424 Separate Air Distribution Systems: Zones with special process temperature requirements and /or humidity requirements shall be served by separate air distribution systems from those serving zones requiring only comfort conditions. to 0 NW W g co _ - W UJ U� ON ca W U Z W = . Z ? IREC5N cvne OF TUKWILA . 2 g 251 PERmq GENTEB 'VANE' 1-1/2 - 5 Ton Split System Cooling or Heat Pump Air Handlers Models TWE018,024,030,036, 042,048C;060C/D 0 American Standard Inc.1996 FILE TWE-D-1 PUB. NO. 22-1298-04 Tab 25 — March 1996 Z • z tu: ce 2 , oc• coca. cow. WI IL uj 0: t a cn D; _ a-• 1 7 0 Au a • • D •: u i • 0 1— u j • C Z 1.11 w r- • 0 , Features: .Ships horizontal - converts to vertical by standing unit on end. .Four way convertibility- horizontal (left & right), upflow, downflow .Electrical, refrigerant, condensate & blower access convertible to either side . Compact 21" depth for easy installation .Corrosion resistant galvanized metal with attractive finish .Superior condensate performance . Uses 1400 series heaters .Enhanced internally finned coil tubes .Direct drive motor .Standard Filters • Multi -speed blower ( Split System Coolin j and Heat Pump Air Handlers • 200/230 volt primary & 24 volt secondary transformer • Low voltage terminal board . Insulated cabinet . Extemal access to heater circuit breakers Model Nomenclature T W E CaTPNWIt PilODUCT .7'YP >~, AIRFLOW CONFIGURATION ,V •- YarbeN H w' NEr.,C0O110 . CAPAgrr fpimiii IAPMERtrfEQ JEMC . .G 8tirittiiiei',Syslani; P miNigh Etfkbnry *Mr! B •;Sult In D!I�rytFunction.. E Eladionia 04 Otht r .Polarized plugs for making electrical connections from air handler control box to electric heaters. (Indoor blower motor powered from heater circuit. ) .Built -in indoor fan delay function for increased efficiency. No kit required. POWER 1 • 200/0300/60 0 A 0 T I T SERVICE Dian! MINOR DESIGN SEQUENCE. F : •Air Trts" 0'.• Stardust, SysIsnt RfFRGE31ANr mow CONTROL 3. Non and TXV - A'= s tFlawCantroVale tVa i • t; :.ac. NsaO TXV ®1" Foil Faced Insulation ®. Enclosed Control Box ® Corrosion Resistant Screws ("') "Air - Titer""" Features Td Benefits ® Liner/Flange Seal Door Casket Exclusive foamed gasket (s misr to a car door gasket) to educe air infiltration and heat transfer ".:• end law' powrr0ils. 'Un.r/Fiar p. Sean - Exausly. Duct Rang. Thermal Break/Sed and double wall construction to reduce :. . oabfrmst *errata' , . ' 1 Folt Faced Insole ion - Thidra tai laced iriaulatbon for reduced cabkist loss, awsdtlng and lowtar • power, bills, Enclosed Control Sox - Totally eirclas.d control box with transformer inside to Improve compo ent Ile, unit durability and reliability: tt -:o ® Corrosion Resistent Screws - Excltaivs 'Wea TM' therguard coated screws to maintain the gwlty,ippsarance of the unit for the Zile ot the product. ® Coupling Panel Insulation' — Exclusive No Bum' refrigerant coupling panel with thmicker Inauledon for reduced heat ices. O Filt r boor sew — Impiowd door s iie:neuoed air • infiltration, heat trend": and bow power tries 'T- ear' fairr R.mon t Ursdo t iicr "shy ilpsr rsplac. nt imgov. s u m aMdt' . bean fltsrs "''" �� • .' `: � .,. ?;. Ireuladon o n C.ntsr B.- Exfra c bor,kmsirlation for rsdresd 'cabinet boss,` s wsst i ng .nd l ows The SEER oust for sriY plsoa�:ilm. sir fermdl.' in the ambient rdum sir stream (00'9. If yar air launder is to be km an unconcttlon.dls vere W loo on you ehoutd c onsi d .r ill adventspss d the 'Ate- TN.""' m odel ak htandlsr. • *—® Door Gasket ® Insulation on Center Bar ® Filter Door Seal ®T -Bar' Alter Removal Brsckei MODEL RATED VOLTS/PH/HZ. RATINGS® INDOOR COL -Type Rows -FP.I. Face Area (sq. ft) Tube Size (in.) Refrigerant Control Drain Conn. Size (NO INDOOR FAN -Type Diameter•Wdth (n.) No. Used Drive - No. Speeds CFM vs. in w.g. No. Motors - H.P. Motor Speed R.P.M. Volts/PMtz F.L Amps - LR.Amps FILTER Verdal Applications Filter Furnished? Type Recommended tlorizonW APPS Filler Recommended Size REFRIGERANT (A-22) Ref. Line Comectlon s Coupling or Corn. Size - in. Gas Coupling or Com. Size - n LA. DIMENSIONS Crated (in.) Uncrated WEIGHT Shipping (Los.) / Net (Los.) MODEL RATED VOLTS/PH/NZ. RATINGS® INDOOR COL -Type Rows - F.P.I. Face Area MA) Tube Size (n.) Refrigerant Control Drain Con. Sin )0 INDOOR FAN -type Diameter-Width (in.) Na Used DrM • Na Speeds CFM vs. hw.g. Na Moors - H.P. Motor Speed RPM libtla/PWHz FL Amps- LR. Amps General Data TWE016C14,0A,FA 208.230/1/60 See 011 Specifications Plate Fn 2 -16 3.21 3/8 - Copper FCCV 314 NPT Centrifugal 9X8 1 Direct - 3 See Fan Perbrmance Table 1- 1/8 1080 200. 23011/60 0.9 -1.6 Yes Throwaway 1- 20X20 -1 it No See Note Brazed 518 1/4 HaWxD 4412x24x23.12 See Mine Drawing 113/103 TWE042C14,013,F8 200.230/1/60 See 0.0. Sped6alior4 Pate Fn 3 -14 3.9 3/8 3/4 NPT Centrilup l 10x8 1 Died -3 See Fan Perlom enceTable 1 -1/2' 1075 200•23011/111X 3.3 7b 1. -20 x202 1 k • No See Note'® 0339 of lrr` +�s�, - • Cristo iifit. • 3113 • p■EN6101K :: , H1W101 Cf�d(h) .. 4. 'ietir; 48- Vt126111ti Wailed .:'' `> See (kits DIMto . . Shipping, (LDeJ/Hof 145/130 • O Thee* Ns HaMira R► *led with vM i Spiitiiim m Con *lonew and Nsst'urnps �AAI 1WE024C14,0A,FA TWE030C14,0A,F TNrE036C14,0A,F 208-230/1/60 200.230/1/60 200 - 2301/60 See 0.0. Specifications See 0.11 Specifications See 0.D. Specifications Plate Fin Prate Fn PI M Fin 2.16 3 -12 3 -14.0 321 2.75 321 3/8 - Copper 3/8 - Copper 3/8 - Copper FCCV FCCV FCCV 3/4 NPT 3/4 NPT 3/4 NPT Centrifugal Centrifugal Centrifugal 9X8 10x8 10118 1 1 1 Direct - 3 Direct - 3 Dined- 3 See Fan Performance Table See Fan Pe bin nce Table See Fan Pwkwm.nce Table 1.1/4 1 -1/3 1 -12 1075 1075 1075 200-230/1/60 200 - 230/1/60 200. 230/1160 1.7 -2.8 2.1 -4.6 3.3.7.3 Yes Throwaway 1. 20X20 -In. No See Note Brazed 3/4 5/16 HxWxD 4412x24 x23.12 See Outline Drawing 115/105 TWE048C14,0B,F 200. 230/1/80 See 0.D. Spedfiatlons Plate Fn 3 -14 5.04 318 - Copper FCCV 3/4 NPT Cenbilupal 10x 10 1 Direct -3 See Fan Perbrmmos Table 1 -12 1075 200s30/1M13 42- 10:7*` 53-1/47i2Sx :y: See Calk. Diliirli0'':. - . 1651160 Yes Throwaway 1.20 x 20 x l n. No See Note Brazed 3/4 5/16 HaWxD 44.112 x 24 x 23.12 See Outline Drawing 120/110 TWE060C/D15,OA,FC 200.230/1/60 See 0.D. Specifications Plate Fin 3 -14 6.19 3/8 • Copper TXVB 3/4 NPT Cen rilugai 11x10 1 Died- 3 See Fan Palominos Tilde 1 -314 1075 200,23011/50 5.9 -14.4 " .. t -1/a 3/3"_ llliwttD a:�:. 5342x a6 xZSVZ so ohm s Dr al' ._ 1861105 ..- STANDARD au rJ!lol - Refer to Me apt ell* Unit Product Doti Gnidae for pieAomence dete. i. • O NO Mate Pleollti Q 2ASTM 1786.70) • O Mi ni+rrn Neer M4ataotOOd�olil.l ippkelkos oil a b� donuriow «i.c+bn end viii lei wioii l:a as bows: Low Velocity 3 aflaS8q. R.) . c:cm /30a:T Yes Tirowsrwy 1- 20x20xtin. No See Note Brazed 7/8 318 HxWxD 44-12 x 24 x 23-12 See °t/re Drawing 1251115 Performance Data NOTES: Vertical With fifer. no horizontal drip tray Small apex baffle. Subtract 0.06' W.G. for downllow. Honrontat As shipped but without filter. Subtract 0.05 W.G. for honzontel left. SEE AIR FLOW RESISTANCE TABLE FOR PRESSURE LOSS WITH SUPPLEMENTARY HEATER. Subllitat 0.06.910. IOr hat: wog ilk Small apex b ac. Stibtrat:t 0.06' W.G. for dowllflow. SEE AIR FLOW RESISTANCE TABLE FOR PRESSURE LOSS WITH SUPPLEMENTARY HEATER. 0 IC m tn N O E 0 (L AIR FLOW PERFORMANCE TWE011C14,0A,FA EXTERNAL STATIC PRESSURE ( INCHES OF WATER ) VERTICAL (See Notes) HORIZONTAL (See Not.) 230 VOLTS 206 VOLTS 230 VOLTS 204 VOLTS CFM HI MED LO HI MED LO HI MED LO HI MED 1.0 100 350 0.62 0.55 0.62 0.46 0.6 150 400 0.6 0.49 0.74 0.58 0.39 0.58 ' 200 450 0.57 0.43 0.72 0.52 0.32 0.51 0.63 0.43 0.54 0.33 250 500 0.53 0.36 0.7 0.47 0.25 0.66 0.58 0.37 0.72 0.48 0.26 300 0.81 0.49 0.29 0.68 0.4 0.18 0.65 0.52 0.3 0.69 0.42 0.19 350 0.6 0.43 0.21 0.64 0.33 0.11 0.64 0.45 0.22 0.66 0.35 0.11 400 0.58 0.37 0.13 0.6 0.25 0.03 0.62 0.38 0.15 0.62 0.26 0.04 450 0.55 0.3 0.05 0.55 0.17 0.4 0.59 0.31 0.07 0.57 0.2 0.43 500 0.52 0.22 750 0.49 0.09 0124 0.55 0.22 0.51 0.12 0.3 550 0.47 0.13 600 0.43 0.76 0.14 0.51 0.14 0.45 0.03 .0.13 000 0.42 0.03 .0 1 0.36 0.511 0.3 0.45 0.04 0.25 0.38 0.12 0.7' 650 0.36 0.26 0.56 0.16 0.39 0.47 0.12 0.3 0.50 0.11 700 0.29 0.19 0.53 0.03 0.32 0.42 0.21 0.56 0.03 750 . 0.21 0.09 0.41. 0.24 0.37 0.12 341 800 0.12 1010' 0.36 0.15 0.31 0.01 0.30 650 0.03 1100 0.06 024 Performance Data NOTES: Vertical With fifer. no horizontal drip tray Small apex baffle. Subtract 0.06' W.G. for downllow. Honrontat As shipped but without filter. Subtract 0.05 W.G. for honzontel left. SEE AIR FLOW RESISTANCE TABLE FOR PRESSURE LOSS WITH SUPPLEMENTARY HEATER. Subllitat 0.06.910. IOr hat: wog ilk Small apex b ac. Stibtrat:t 0.06' W.G. for dowllflow. SEE AIR FLOW RESISTANCE TABLE FOR PRESSURE LOSS WITH SUPPLEMENTARY HEATER. 0 IC m tn N O E 0 (L AIR FLOW PERFORMANCE TWE024C14.0A,FA EXTERNAL STATIC PRESSURE ( INCHES OF WATER ) VERTICAL (See Noise) HORIZONTAL (See Notes) 230 VOLTS 200 VOLTS 270 VOLTS 200 VOLTS CFM HI MED 10 HI MED LO HI MED LO HI MED 1.0 350 0.6 301 400 0.58 ' 0.50 450 0.51 0.52 500 0.11 0.42 0.63 0.51 0.43 560 0.50 0.34 0.02 0.56 0.47 0.34 000 0.01 0.55 0.52 0.22 0.115 0.6 0.51 0.41 an 160 0.57 0.44 0.5 Al 0.6 0.54 0.52 0.33 0.1' . 700 0.52 0.4 0.46 0.56 0.43 0.47 0.25 750 0.47 0124 0.42 0,49 0.3 0.43 0.15 600 0.6: 0.76 0.14 0.63 0.34 0.63 0.41 .0.13 0.36 001 .0 1 150 0.511 0.3 0.5 0.25 0.12 0.7' 0.31 100 0.56 0.16 0.47 0.12 0.50 0.11 0.27 960 0.53 0.03 0.42 0.56 0.03 0.14 1000 0.41. 0.37 341 1010' 0.36 0.31 0.30 1100 '023 024 029 :•• 1150 0.11 0:17 0.19 1200'. 0.1 . 6011 , _ 611 1210 0.02 . "NITRES Manias* WMi Mei rso 1leitzrnet thin trey Hatters* As shlooed but Wiwi 99ttc ,_. _... Performance Data NOTES: Vertical With fifer. no horizontal drip tray Small apex baffle. Subtract 0.06' W.G. for downllow. Honrontat As shipped but without filter. Subtract 0.05 W.G. for honzontel left. SEE AIR FLOW RESISTANCE TABLE FOR PRESSURE LOSS WITH SUPPLEMENTARY HEATER. Subllitat 0.06.910. IOr hat: wog ilk Small apex b ac. Stibtrat:t 0.06' W.G. for dowllflow. SEE AIR FLOW RESISTANCE TABLE FOR PRESSURE LOSS WITH SUPPLEMENTARY HEATER. 0 IC m tn N O E 0 (L (-a% 'erformance Data NOTES: 1. With wet cod; t9ter In place: no heater installed. 2. See airflow resistance tads for pressure loss with supplementary heaters. 3. Tray is in place tor all positions. From Dwg.21A800075 Rev. 2 NOTES 1. WMr wet soft Mar in piton no hitter Installed. 2. See sallow mince leak ix pressure loss wIth supplementary heelers. 3. Vey is In place brae ptisllions. 4. SsMss are Melees tor doeulbw. AIR FLOW PERFORMANCE TWE030C14,0A,F EXTERNAL STATIC PRESSURE (IN. W.O.) UPFLOW a IIOIZONTAL RIGHT DOWNFLOW - BAFFLES INSTALLED HORIZONTAL LEFT 230 VOLTS 2011 VOLTS 230 VOLTS 201 VOLTS 230 VOLTS 206 VOLTS CFM HI MED LO HI MED LO HI MED LO HI MED LO HI MED LO HI MED LO 650 0.85 0.82 0.65 0.85 0.78 0.50 0.75 0.71 0.56 0.75 0.67 0.41 0.84 0.80 0.65 0.84 0.76 0.50 700 0.84 079 0.60 0.83 0.74 0.43 0.71 0.65 0.50 0.70 0.60 0.33 0.81 0.75 0.60 0.80 0.70 0.43 750 0.81 0.75 0.54 0.80 0.68 0.33 0.66 0.59 0.43 0.65 0.52 0.22 0.77 0.70 0.54 0.76 0.83 0.33 800 0.78 0.70 0.47 0.76 0.61 0.20 0.61 0.52 0.35 0.59 0.43 0.08 0.73 0.64 0.47 0.71 0.55 0.20 850 0.74 0.65 0.38 0.72 0.54 0.03 0.54 0.44 0.24 0.52 0.33 0.68 0.58 0.38 0.66 0.47 0.03 900 0.70 0.59 0.29 0.67 0.45 0.46 0.36 0.13 0.43 0.22 • 0.62 0.52 029 0.59 0.38 950 0.65 0.52 0.16 0.62 0.35 . . 0.38 0.27 0.35 0.10 0.56 0.45 0.16 0.53 028 1000 0.59 0.44 0.03 0.55 0.24 0.30 0.18 0.26 0.50 0.38 0.03 0.46 0.18 1050 0.53 0.35 0.48 0.12 0.21 0.07 0.16 0.43 0.29 0.36 0.06 1100 0.46 0.26 0.40 0.12 0.06 0.36 0.19 0.30 1150 0.39 0.17 0.32 0.28 0.21 1200 0.31 0.07 0.23 0.20 0.12 1250 0.23 0.14 0.11 0.02 (-a% 'erformance Data NOTES: 1. With wet cod; t9ter In place: no heater installed. 2. See airflow resistance tads for pressure loss with supplementary heaters. 3. Tray is in place tor all positions. From Dwg.21A800075 Rev. 2 NOTES 1. WMr wet soft Mar in piton no hitter Installed. 2. See sallow mince leak ix pressure loss wIth supplementary heelers. 3. Vey is In place brae ptisllions. 4. SsMss are Melees tor doeulbw. AIR FLOW PERFORMANCE TWE036C140.0A,F EXTERNAL STATIC PRESSURE (IN.W.G.) UPFLOW a HORIZONTAL RIGHT DOWNFLOW a HORIZONTAL LEFT 230 VOLTS 201 VOLTS 230 VOLTS 208 VOLTS CFM HI MED 10 HI MED 10 HI MED LO II MED LO 750 091 0.69 0.84 0.75 0.80 093 800. 0.87 0.76 0.82 0.62 0.87 0.79 069 0.85. 0.74 0.56 850 0.83 0.70 0.76 0.53 0.83 0.74 0.62 0.81 0.87 0.48- 900 0.85 0.78 0.64 0.84 0.71 0.43 0.78 0.88 0.55 0.75 0.61 0.34 960 0.8t 0.73 057 0.78 0.64 0.28 0.73 0.61 0.47 0.70 0.52 41e' 1000. 0.76 0.67 0.49 0.72 0.58 0.67 0.54 0.30 0.83 0.43 1100 0.84 0.53 0.28 0.59 0.37 0.53 0.39 0.18 0.48 0.23 1200 ' CtliO: 0.37 0.02 0.44 0.14 0.38` 0.23 ' ' 0.32 � ' 0.00 1300 0.36 0.20 0.29 0.22 0.06 0.15 • -1400 ' 0.22 OA2 0.13 O.07 . - ... _ - . . . . oa7 ; Flom Dets.2U800077 Rai 2' (-a% 'erformance Data NOTES: 1. With wet cod; t9ter In place: no heater installed. 2. See airflow resistance tads for pressure loss with supplementary heaters. 3. Tray is in place tor all positions. From Dwg.21A800075 Rev. 2 NOTES 1. WMr wet soft Mar in piton no hitter Installed. 2. See sallow mince leak ix pressure loss wIth supplementary heelers. 3. Vey is In place brae ptisllions. 4. SsMss are Melees tor doeulbw. - AIR FLOW PERFORMANCE TWE042C14,08,FB EXTERNAL STATIC PRESSURE (IN. W.G.) UPFLOW 6 HORIZONTAL RIGHT OOWNFLOW 6 HORIZONTAL LEFT 230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS HI MED LO HI MED LO HI MED LO HI MED LO 900 1000 0.87 0.74 1.00 0.78 0.51 0.87 0.76 0.61 0.82 0.67 0.38 950 1100 0.82 0.67 0.88 0.72 0.39 0.82 0.70 0.54 0.77 0.60 0.26 1000 0.88 0.77 0.59 0.83 0.65 0.22 0.77 0.64 0.46 0.72 0.52 0.09 1050 0.83 0.72 0.50 0.78 0.58 0.00 0.72 0.58 0.37 0.67 0.44 0.57 1100 0.78 0.88 0.40 0.73 0.50 0.58 0.66 0.51 0.28 0.61 0.35 0.55 1150 0.73 0.60 027 0.67 0.40 0.43 0.60 0.44 0.16 0.54 0.24 . 0.41 1200 0.67 0.54 0.11 0.60 0.29 027 0.55 0.36 0.02 0.48 0.11 i 0.26 1300 0.58 0.38 031 ' 0.47 0.06 0.08. 0.42 0.21 0.32 0.33 `0.3T . ids. 1400 0.44 0.20 0.15 0.33 0.30 0.29 0.05 a20 0.18 ; O.Zt . 1500 0.31 0:Z2 0.19 - 0.13 0.15 a00. 0.01 ; atl0 1600 0.16 irriat Dais 2UN00127 d° 0.03 • 1700 0.01 _ arformance Data NOTES: 1. With wet coil: filter in place; no heater installed. 2. See aldlaw resistance table for pressure loss with supplementary heaters. 3. Tray is in place for all positions. From Dwg. 21A800076 Rex 2 WloK WWI dr andante" 11mbal N. 021121211;, US( irstiscspl. VAIlvAorlsilildtlptlsyi - dl4inptirtttillIsa ddit MIII iiR II llall�bilt As shipped scope vAhout INN -I AIgh.epeed. mhos E S P O .Z ' WC , . mdmanlLR Lis ModzotNM Right NIP'pt- - tor moats epsed !Sloss WO.OTWC, Wilt NMI@ spot ttdlte - tot N tpes4 ',duos ESP Oy 0.0T W C. - tor medurnspeed. reduce ESP by0:06'W.C. SEE AIR FLOW RESISTANCE TABLE FOR PRESSURE LOSS WITH SUPPLIIMENTANV WAFERS. 0 0 ? N W NIL; 2 J: D Q; O N' W Z. 0 (. X .0 AIR FLOW PERFORMANCE TWE048C14,OB,F EXTERNAL STATIC PRESSURE (IN. W.G.) UPFLOW (See Nolen) HORIZONTAL RIGHT (Sera Noise) 230 VOLTS 20S VOLTS 230 VOLTS 208 VOLTS CFM HI MED LO HI MED LO HI MED 10 HI MED LO 1000 1.00 0.95 0.97 0.92 1100 0.90 0.94 0.82 0.97 0.87 0.90 0.711 1200 0.91 0.81 0.96 0.83 0.71 0.96 0.87 0.75 0.92 0.79 0.� • ` 1300 0.90 0.81 0.71 0.85 0.71 0.55 0.86 0.75 0.67 0.81 0.57 0.92 1400 030 0.80 0.80 0.79 0.58 0.37 0.76 0.65 0.5a 1 0.71' 0.55 Q16. • 1500 030 0.57 0.45 0.64 0.43 0.11 0.65 0.54 0.41 0.80 . 0.41 0.10„ 1600 a58 0.44 0.27 0.54 027 0.53 0.43 0.24 0.41 i 0.26 1700. .00.47 031 ' 0.05 0.42 0.08. 041 0.32 lion `0.3T . ids. 1800 038.. 0.15 0.30 0.28 a20 ; O.Zt . • 1900 0:Z2 - 0.15 a00. . ; atl0 irriat Dais 2UN00127 d° arformance Data NOTES: 1. With wet coil: filter in place; no heater installed. 2. See aldlaw resistance table for pressure loss with supplementary heaters. 3. Tray is in place for all positions. From Dwg. 21A800076 Rex 2 WloK WWI dr andante" 11mbal N. 021121211;, US( irstiscspl. VAIlvAorlsilildtlptlsyi - dl4inptirtttillIsa ddit MIII iiR II llall�bilt As shipped scope vAhout INN -I AIgh.epeed. mhos E S P O .Z ' WC , . mdmanlLR Lis ModzotNM Right NIP'pt- - tor moats epsed !Sloss WO.OTWC, Wilt NMI@ spot ttdlte - tot N tpes4 ',duos ESP Oy 0.0T W C. - tor medurnspeed. reduce ESP by0:06'W.C. SEE AIR FLOW RESISTANCE TABLE FOR PRESSURE LOSS WITH SUPPLIIMENTANV WAFERS. 0 0 ? N W NIL; 2 J: D Q; O N' W Z. 0 (. X .0 NUMBER OF RACKS HEATER MODEL NO. 1 2 1 3 1 4 I s AIRFLOW CFI MR PRESSURE DROP INCHES W.G. I 500 0.01 0.@ 0.02 BAYaemmt4ta BAYMIX142f 700 0.01 602 0.02 LO HI 000 0.02 , 0.06 0.02 QAs 1300 500 0.03 0.03 0.04 0.05 0.49 1000 0.04 ` 0.04 . 0.06 0.0• 0.49 1150 . 0.04 0.05 0A5 0.07 0.05 1200 0.05 0.06 .0.07 0.00 0.61 .. .1300 11.1111- 0.07 ' OAS OM - 0.11 •..1400' OW. . 0.10 0.11 0.13 1500' OAS - ' 0.05 0.11 0.13 0.15 1 6oQ. 0. 00. . 0.10 - . 0.12 0.15 ' 0.17 .1700 ' G10" _0.11. 0.14 0.17. 0.111 . 1500 :. 0.11. ' 0.13. 0.16 0.10 021 1000 " 0.13' 0.15 0.15 6.21 023 2000: 0.14' 0.17 020 023 625 HEATER RACKS HEATER MODEL NO. NO. OF RACKS BAY96X1406 04 :N 'N M .h ''d :* IA M A E09014o6 BAV9I XI40S' eAYSMXu/o • •Bmileic 4/S BAYaemmt4ta BAYMIX142f BAYOMX1420 BAYMIX3412' 8AV9MX34IS (." Performance Data tliallart With filter and small apex battle. Without horizontal drip tray. talRlptlt As shipped except wi5lout filter lLett Like Horizontal Right erxept - - with small apex baths - tor high speed, reduce ESP by 0.0T W.C. - tor medium speed. reduce ESP by 0.05' W.C. From Owg.21A147522 Rev. 0 0o i fbo ec Like Upflow except - - drain pan baffles added - br high speed, reduce ESP by 020' W.C. - for medium speed. reduce ESP by 0.07* W.C. SEE AIR FLOW RESISTANCE TABLE FOR PRESSURE LOSS WITH SUPPLEMENTARY HEATERS. PRESSURE DROP FOR ELECTRIC HEATERS IN AIR HANDLER MODELS t.,466 praMaxtD6ltot�t4n�IMpMtt6 br:pplo±rdgcornbu�alrpt lNid lsand' • Alai( 2 HI1 ffi tunti6i ..�n:xhyc AIR FLOW PERFORMANCE TWE060CI5FC, TWE0600150A EXTERNAL STATIC PRESSURE (IN. W.G.) UPFLOW (SEE NOTES) HORIZONTAL RIGHT (SEE NOTES) 230 VOLTS 205 VOLTS 230 VOLTS 206 VOLTS CFM HI MED LO HI MED LO HI MED LO HI MED LO 1300 0.78 0.49 0.76 0.49 1400 0.64 0.26 0.64 1.26 1500 0.47 0.71 0.47 0.71 1800 0.76 027 0.84 0.76 027 0.64 1700 0.67 0.00 0.79 0.52 0.87 0.00 0.76 0.52 1800 0.79 0.56 0.72 0.34 0.76 0.56 0.89 0.34 1900 0.72 0.42 0.65 0.12 0.68 0.42 0.61 0.12 2000 0.64 025 0.56 0.60 025 032 2100 0.56 0.05 0.47 0.51 0.05 0.42 2200 0.46 0.36 0.41 0.31 2300 0.34 0.22 0.28 0.18 2400 0.20 - 0.13 (." Performance Data tliallart With filter and small apex battle. Without horizontal drip tray. talRlptlt As shipped except wi5lout filter lLett Like Horizontal Right erxept - - with small apex baths - tor high speed, reduce ESP by 0.0T W.C. - tor medium speed. reduce ESP by 0.05' W.C. From Owg.21A147522 Rev. 0 0o i fbo ec Like Upflow except - - drain pan baffles added - br high speed, reduce ESP by 020' W.C. - for medium speed. reduce ESP by 0.07* W.C. SEE AIR FLOW RESISTANCE TABLE FOR PRESSURE LOSS WITH SUPPLEMENTARY HEATERS. PRESSURE DROP FOR ELECTRIC HEATERS IN AIR HANDLER MODELS t.,466 praMaxtD6ltot�t4n�IMpMtt6 br:pplo±rdgcornbu�alrpt lNid lsand' • Alai( 2 HI1 ffi tunti6i ..�n:xhyc t r ✓ r r r ✓ x At ¢ r r r r r ✓ r rr rr ✓ r ✓ x x 1i At r ✓ r r r r, r r r X rs I� T . r. rr rr ✓ r ✓ r rr ✓ r r r r r r r r ✓ r r r ✓ i- r r r r r n z r r r r r r rr r r r r rr r r 2 r 1 ✓ r rr ✓ r r r rr ✓ r r r r ✓ r rr r X x i r r r r r r rr r r ✓ r r r r- r r r rr X r r r r ✓ r r r r r r r r r r r r r r r r r rr r r r r r rr rr rr rr rr rr ✓ r r ✓ r r r r r r rr r r r r r r r r r r r r r r � r r� r rx r rl r r rl r r ✓ ir ✓ i rir ✓ lx 1 IX m r r r r r r r r r r r r- r r r r r r ✓ r r r m r r r r r r r r r r r r ✓ r r F ✓ S r r 0 x S A m 0 r r r r r r r r r r ✓ r r r r r r r r r r ✓ 0 S 0 I" E rl r rl r r ir r r r r r oc r� r 12 FIX r r r- r r r ✓ r- r r r r r r r ; E ; I r r r r r r r r- r E r C r r r C r r r r ✓ r r r r r r r r r r r r 0 c 3 r r r r r r r r r r C r r r r r r r C r r- r r r r rr r r r r r r r r r r r r r r r r r r r ✓ r r C r r r r r r r r r r r r r r r r r r r r g r r r r r r r r r r • r r r r r r ; r r r C ✓ c c Ia< p � O o ? a 1 r r r r ✓ r F . x CD 0 c 3 ,NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. g c r r r r r � r r c< a 5 0 m 3 e r r r r r r r 9 0 0 in =I> r, -n a ED: -0: CD 0. 1 r performance Data TWE018C WIRING DATA (Indoor Blower Motor Powered from Heater Circuit 1) Capacity 0 Minimum Circuit Healer Maxim Overload Stages Number Contains um 240V Rated Amps Amps Circuit or of p per Circuit Heater Heater KW BTUH Voltage 208 240 Steps Circuits 208 240 Breakers 208 240 Model No. 4.8 16,400 208. 240/1/60 23 26 1 1 17.3 5.76 19.600 208. 240/1/60 27 31 1 1 20.8 7.68 26,200 208 - 240(1/60 36 41 1 1 27.7 9.6 32,800 208. 240,(1/60 45 51 1 1 34.7 9.6 32,800 208 - 24011160 45 51 1 1 34.7 10.56 36.100 208 - 240/1/60 49 56 1 1 38.1 10.56 36.100 208-240/1/60 49 56 1 1 38.1 10.56 36.100 208. 24013/60 31 36 1 1 '242 NOTES: CAUTION: Any power supply and/or combination power supply. circuit or circuits must be wired and protected in accordance with local Electric Codes. . TWE024C WIRING DATA (Indoor Blower Motor Powered from Heater Circuit 1) Capacity 0 Minimum Circuit Stages Number Heater Contains Maximum Overload 240V Rated Amp or of Amps per Circuit Circuit Protection Heater KW BTUH Voltage 208 240 Steps Circuits 208 240 Breakers 208 240 Model No. 4.8 16,400 208 - 240/1/60 24 27 1 1 17.3 20 No 25 30 BAY96X1405 5.76 19,600 208 - 240/1/60 28 32 1 1 20.8 24 No 30 35 BAY96X1406 7.68 26,200 208-240/1/60 37 42 1 1 27.7 32 No 40 45 8AY96X1408,8F 9.6 32,800 208-240/1/60 46 52 1 1 34.7 40 No 50 60 8AY96X1410,10F 9.8 32,800 208-240/1/60 46 52 1 1 34.7 40 Yes 50 60 BAY96X1410A 10.56 36,100 208- 240/1160 50 57 1 1 38.1 44 No 50 60 BAY96X1411 10.56 36,100 208- 240/1160 50 57 1 1 38.1 44 Yes 50 60 BAY96X1411A 15.36 52.400 208- 240 46/26' 52/30• 2 2 34.7/20.8' 40/24' Yes 50 60130• BAY96X1415 10.56 36.100 208. 240/360 32 37 1 1 242 28 No 35 • 40 BAY96X3411 15.36 52,400 208 - 240/3/60 45 52 1 1 36 41.6 No 45 60 BAY96X3415 NOTES: Grant 1/Circuit 2/Circuit 3 CAUTION: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local Electric Codes. TWE030C WIRING DATA (Indoor Blower Motor Powered from Heater Circuit t) Capacity Mtpecity Mips p er tit contain.. Pia on Rated or d Circuit Heater KW BTUH Voltage 208 240 Steps .. Ciroits 208 240 Breakers 206 240 Model No 4.8 18,400 208.24011160 24 28 1 1 17.3 20 No 25. 30 BAY96X1405 .. .5.76 '19,600 20624011160 29 33. • 1 1 20.8 24 No 30" 36 BAY96X140t 7.68; 26.200 208. 24011160 37 43 1 1 27.7 32 No 40 45 BAY96X1400,8F' 9.6 32.800 208. 24011460 46. 53: 1 1 34.7 .40 No 50 60 BAY98X1410`10F • 9.6 32.800 206- 240/1460 46 53 • .1 1 34.7 40 Yes 50 80 BAY96X1410.4 10.58. 36100' 208. 24011460 50. 56.• . .1 :1 '.310 :44 No 50' . • ea BAY98X14tt` 10,56 .36.100 20624011160 50 58 1 1 ' X38.1 :44 .. Yes. 150: : - 60 BAY96X14714t .15:38. 52.400. 20824011400' . 489.28' :59/90' T 2, .34//209'• 7 .4. 1 4 X4 .'. • ,�P94• BAY96X140 19.20 65.500 206. 24011460 '46143` 531'50'. 2' 2 34.7134.7 • 40140' Yes war 6 8AY98X1419 21.12 72,100 2011-240/1/80 46152' 53160' 2 2 34.71,414• :40148'' •Yas: 461107, a01!80' 13AY96X140 10.56 35.100 206240/1/60 33: 38' 1 ;1 24.2 18 No oy 40 BAY96X6411 15.36 52,400 208. 24013/80 45 52 1 1 36 41.6 No 46 60 6AY960415 No No No No Yes No Yes No NOTES: Circuit 1/Clrcult 2/Circuit 3 CAUTION: Any power supply and/or combination power supply, circuit or circuits must be wired and protacled N wa rdenoe. with load Electric Codes. BAY96X1405 BAY96X1406 BAY96X1408.8F BAY96X1410,10F BAY96X1410A BAY96X1411 BAY96X1411A BAY96X3411 f Performance Data TWE036C & TWE042C WIRING DATA (Indoor Blower Motor Powered from Heater Circuit 1) Capacity 0 Minimum Circuit um Number Heater Contains Maximum Overload 240V Rated Ampacity or of Amps per Circuit Circuit Protection Heater KW BTUH Voltage 208 240 Steps Circuits 208 240 Breakers 208 240 Model No. 4.8 16,400 208 - 240/1/60 26 29 1 1 17.3 20 No 30 30 BAY96X1405 5.76 19.600 208 - 240/1/60 30 34 1 1 20.8 24 No 30 35 BAY96X1406 7.68 26200 208 - 240/1/60 39 44 1 1 27.7 32 No 40 45 BAY96X1408,8F 9.6 32,800 208- 24001/60 48 54 1 1 34.7 40 No 50 60 BAY96X1410,10F 9.6 32,800 208 - 24001/60 48 54 1 1 34.7 40 Yes 50 60 BAY96X1411 10.56 36,100 208- 240/1/60 52 59 1 1 52 59 No 60 60 BAY96X1411A 10.56 36.100 208 - 24011/60 52 59 1 1 52 59 Yes 60 60 BAY96X1410A 15.36 52,400 208 - 240/1/60 48/26' 54/30' 2 2 34.7/20.8' 40/24' Yes 50130' 60/30' BAY96X1415 19.20 65 ,500 208 - 24011/60 48/43' 54/50' 2 2 34.7/34.7' 40040' Yes 50145' 60/50' BAY96X1419 21.12 72,100 208 - 240/1/60 48/52' 54/60' 2 2 34.7/41.6' 40/48' Yes 50/60' 60/60' BAY96X1421 10.56 36.100 208 - 240/3/60 34 38 1 1 24.2 28 No 35 40 BAY96X3411 15.36 52,400 208- 240/3/60 45 52 1 1 36 41.6 No 45 60 BAY96X3415 NOTES: ▪ Circuit 1/Circuit 2/Circuit 3 CAUTION: My power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local Electric Codes. TWE048C WIRING DATA (Indoor Blower Motor Powered from Heater Circuit 1) Capacity 0 Minimum Circuit S s Number Heater Contains Maximum Overload 240 V Rated Amp ty or of Amps per Circuit Circuit Protection Heater KW BTUH Voltage 208 240 Steps Circuits 208 240 Breakers 208 240 Model No. 4.8 16,400 208- 240/1/60 27 30 1 1 17.3 20 No 30 30 BAY96X1405 5.76 19,600 208- 240/1/60 31 35 1 1 20.8 24 No 35 35 BAY96X1406 7.68 26,200 208- 24011/60 40 45 1 1 27.7 32 No 40 45 8AY96X1408,8F 9.6 32,800 208- 240/1/60 49 55 1 1 34.7 40 No 50 60 8AY96X1410.10F 9.6 32.800 208 - 2401/60 49 55 1 1 34.7 40 Yes 50 60 BAY96X1410A 10.56 36.100 208.2301060 53 60 1 1 38.1 44 No 60 60 8AY96X1411 10.56 36,100 208 -240 /1/60 53 60 1 1 38.1 44 Yes 60 60 BAY96X1411A 15.36 52,400 208 -240 /1/60 49/26' 55/30' 2 2 34.7/20.8' 40/24' Yes 50/30' 60130' BAY96X1415 19.20 65.500 208 - 240/1/60 49/43' 55/50' 2 2 34.7/34.7' 40/40' Yes 50/45' 60150' BAY96X1419 21.12 72.100 208- 240/1/60 4052' 55/80' 2 2 34.7/41.6' 40/48' Yes 50/60' 60160• BAY96X1421 25.92 88, 500 208 - 24011/60 49/52/22• 55160125• 3 3 34.7/41.6/17. 40 /4820' Yes 5016025 6016025' BAY96X1426 10.56 36,100 208 - 240/3/60 36 40 1 1 ' 24.2 28 No 40 40 8AY96X3411 • :5.36 32,400 208-240/3/60 45 52 1 1 36 41.6 No 45 60 BAY96X3415 NOTES: • Circuit 1/CAuuit 2/Circuit 3 CAUTION: Any power supply and/or combination power supply, dretit or circuits mint be wired and protected in accordance with load Electric Codes. TWEO60C/D WIRING DATA (Indoor Blower Motor Powered from Circuit 1) Minimum Circuit Ntarltbar Hooter Cared Matonaan Ovsdoed Straw Rated Am P or d A w Circuit Circti6 Pf O ' Heater Voltage 208 240 Steps Cktuits 208 240 Breaker) 208 '240 Model No. Capacity o 240V KW BTUH 4.8 16400 208.240/1/80 29 33 1 1 17.3 20 No 30 35 BAY98X1466 5,76 19900 208.24011160 34• ' 38 1 1 20.8 :24: No. 35 40E BAY98X14011.. - 7.68 '26900. 208.240/1/60 42 48 1 1 27.7 32 No. 45 50 BAY96X110t1,8F 9.6 32800. 208.240/1/60 51 58 1 1 34.7 40 No 60 . d0= BAY96X141.Q;10F 96 32!04 208440/1180 51 SO 1 1 34.7 14 Yea 60 10, .. 8AY96X10OfA; 15.36 52.400 206.240/1160, 51/26' 58/30'_ 2 A. 347/20.8' . 40/24' Yes 60/30' 41W90* BAY96X1415 . . 1920 66,500' ' 208.240/1/30 51143•' 58/50*' 2 2 .34.7/347' � 40 40''. Yes 0030/6'' MO! BAY96X141e 21.12 72.100 208=24011410 51152' 58160' 2' 2 34.7/41:9' 40i48't yes Orr Oder BAY9M1421 ? '' 25.92 88.500 '206.240/1100. 51/52/22 58190125' 3 3' 37/41.6/17.3' 40148120' Yee 60180(25' Amor BAY96X1426 . 10.56 38.100 208-240M/80 38 43 1 1 242 28 No, 40 • 45: 8AY96X3411. . . 15.38 52.400 208.240(3/80 46 52 1 1 36 41 .t . ' No So . 80 BAY96X341S NOTES: • Circuit 1/CYait 2 kadt 3 CAUTION: Any power supply and/or combination power supply. rircu1 or dew its must be wired and protected in accordance wit loot Dwelt Codes. 11 `r:,i:.:a:•,.: + V' ode': e. .1'�.:#...i...,,�i:;,..la..�x�. Z _ • !- W cow 0/ p W O. g -j J u. Q; . 0/ I- ) - ' uj 0 o W U. U = ` ~O I•- 5 1 4, • ((^ _ 1( - N *12 �— WH /I Unit Wiring WIRING DIAGRAM FOR TWE018- 048C;TWE060CID AIR HANDLER (SEE LEGEND) 200/230 V. I PH..60 HZ. POWER SUPPLY PER LOCAL CODES r`. ,� h I -PM t j -PF INOTE 21 * THERMALLY PROTECTED `1 I -PMCt) I -PF I j FOR - 1 °: —� BK /4" R D/2 --- 3p-1 ILL" CF 2-PM I r--- 2 -PF (NOTE 31 CRD /3 8L /I ••••81(/3 -WHITE BLACK/BL FDR •2 a r 41 /J 6 -i 1-0 B r ,!I INTERNALLY B , l I LVIB I Y2I W3F WZI W1I Y I1 T 0 1 B 13 I R S I D FAN MTR M BLACK TMs *13 --- SEC BLACK/RD BL FOR LEGEND r1 (NOTE II RED FU RED NOTES: I. FOI 200 Y. OPERATION. OISCONMECT RED TRANSFORMER LEAD FII0M CM -I AND INSULATE. CONNECT COMM TRANSFORMER LEAD TO REMAINING TWO RO -I LEADS IN CM -I. 2. NRlEM HEATERS ARE USED. DISCARD i -PM WITH ATTACHED LEADS AND CONNECT I-PF TO.T1E MATING PLUG IN TIE HEATER CONTROL SON. .3 ACCESSORY NIT SAY24K03S MAY NE USED *EN AUTOMATIC SPEED CHANGE FOR IEATUIOICOOLIISiOtERATION IS DESIRED. 210000006 POO ��:... 2411. FACTORY: • •? CIE rr "TRANSFORMER p: ti. .K FELD FUSE •0 • TERMIIM. eLoculoot • . �.: NELAr.COMT TNQ MAONETC•COR. .:: Ri1T Ct>fIIECTOR 11IALE- TEgMIIRLS17.;..: ` < 1EIIMNIAL • POI.'PLYO YALE'Na1S1aI IFEMALE.TERMIIALSI NOTE: Fuse on 030-060 only. FIELD WIRING DIAGRAM FOR TVVE018,024,030,036,042,048,060 AIR HANDLERS WITH SINGLE SPEED COOUNG UNIT AND TWO STAGE HEATING THERMOSTAT ROTES: 1. PO0ER 0111100 410 01000010i or TOullIvt0T IMUST COVILT 01t01,0C.1/4. COOTS. Z. SI SIM POWER SUM T WOES MTh (01.111 RAIIIPLATE. 3. L00 V01.144( RP1100 TO OE 10.111 LILL 111111ERS CORMTOR. USE COPPER CORMTORS MT. S. MARINO PLUS SECTION P11.0 IS ATTOCK0 TO WATER CCOTROL S. SECT10111•PC PACTOIT RIND TITO AIR 161/0.111. G. IP LOS *ENT C001.1110 131100.10.1*31 ORYLOAR1008123711 OR OAK MINA MOM { TO POKR SUPPLY PER LOC& COCES mut I. room op ON MS ateacue or 14164211 MIST MKT 111711 LOCK COOLS. 2. St SLK MOIR !IMPLY MIKIS MIR • 411121IRT 3. ' L00 VILTAK MIMS TON IS SAL oomaiieloonnot. ix ions CleitTOIS ONO, • - • Field Wiring FIELD WIRING DIAGRAM FOR TWE018,024,030,036,042,048,060 AIR HANDLERS WITH SINGLE SPEED COOUNG UNIT AND SINGLE STAGE HEATING THERMOSTAT " 1 MAINS OLIO WO P11 4 MAWR IMAMS Cala OIL ISCTIS* 100 IS • ?11T.1P .1,AaP, a. yea son vow. nal emictrouopoion JIIIIII111111111111 NKr& Lai irsari-S airO4 les Lunt soltoosoom n 11A11.0AORM • ' t tig :4 0F 1 .4cogli 5100.2 MCP sEc rpm ROOM THERMOSTAT CAT. NO. GAl221183 WITH SUB•BASE CAT. NO. GAl282195 SET 'WIER MUM mu or. sr. SHOIN 00 0011101 mom CIELO 1111% SEE NOTE S E immommimmul INTER-COMPONENT MIRING 24 V. racToRy - LINE V.f mums 24V. 1 F IELO LINE Y. 1112 116 ROOM THERMOSTAT AY21X032 OR AY2IXIoS sti Twit ha HAROLD 10110121013 so sum 41Mo. F E L AMK] IMED •MA•PER COMO TIM 111, 111. SR MIMS INIMR8 Ll mm isiiiii .... a a ir.. 111111111111■11•14111321471121231321421K141 — Nii/11.11111.1111ESESISMI...:._ 111-20 sr • ;--. ,.- ,:,:- •. ,'-'_ .• .• .... 112_77 L aikilit_ 40 -1 , : t ilia irgincar: :::,.. .. 1.' -...- LINE 1 • LINE r VIIIIMI ' 0 fl TO PONER SUPPLY PER LOCAL CODES 6 AS CEP INE0 IN IELO HIRING TABLE MR HANDLER 21111310722 ROM Ovig.218131072 Ray.2 TO PONER SUPPLY PER LOCM. CODES L AS CET IWO III FELD WNW TAME R•mpaitait#:4 1:3 .; • . ;;';• • fi eld Wiring FIELD WIRING DIAGRAM FOR TWE018,024,030,036,042,048,060 AIR HANDLERS WITH HEAT PUMP P00N TTIERNOSTAT BATINNLI8 UR GAr18TI)9 -R opveINe =816 TAYBASE100 :2>"3tt 4413/16 TAYBASE101 ` 2t 4 . 14=19/16 • ,TAYBASE102 26+(4. 14=13/16 l0TES: 1. rout) *PIKM0GIWNOt11 ECtiVig Nt YJST C3YPL1 W.. LOCAL CCLS. 2. IR[ SUIE PORN SURLY A US NITN EOUPIIENT IAIQPLAt(. 1. Lew YC. ?L. k 1FNG 10 BE w:. 2 kg G. 11N1wr CONDKTra. 4. USE COIPIN CONLICTORS MAT. S. POVAIRO RLAI WCna PV•* K AfTACN10 10AMA COITAL ION. S1C11011• ! 10 (011011 1*1 INTO AM NAN0.111. I. It 001 SSA MO. MA COBALT ARIRPRWIE AN/EIS maw To 11f AIN AO III LAIL T. 11R1*0 S 4 MO w1 Nt. AWE 111(110., CONNECT 1011 ALT IT 210 o $1c01111TAIR ME USEOel Tl( NEARED COP COMMOII P0610 TOELECIIK IEATIN0 EILKI1S. 1f 210IAOMAGN CONTACTORS ME MT IMO. T1EO PILO Comma's IONS 10 .2 MN R7 CM K 01111 OvOOPAIUE. 0. CONNECT is 10111M1ER 11 0.0.011T MS T CO1ECTION. NEAT PUMP 0.0. SECTION N ROME 910a TO POMER SUPPLY{ PER LOC* SUPPLY{ CDOES REQUIRED ��_ CDR 3 PR - 001•' 001'.2 [900 ®uUUMUU INTER•COYPONENT MIRING 24 v. FACTORY LINE Y. WIRING 24 y. 1 F IELD LINE Y.f WIRING An WIRE REQUIRED FOR 3 PH t0 PDNER SUPPLY PER LOCAL CODES 4AS DEC' INED IN FIELD WIRING TABLE SUM. NTR. CONTROL 801 PM •A I•Pr SEE NOTE 5 AIR HARMER NOTES G47 1 _..1 218131071 R 2.1 From DWq.21E1131071 Rall2 YODEL fi eld Wiring FIELD WIRING DIAGRAM FOR TWE018,024,030,036,042,048,060 AIR HANDLERS WITH HEAT PUMP P00N TTIERNOSTAT BATINNLI8 UR GAr18TI)9 -R opveINe =816 TAYBASE100 :2>"3tt 4413/16 TAYBASE101 ` 2t 4 . 14=19/16 • ,TAYBASE102 26+(4. 14=13/16 l0TES: 1. rout) *PIKM0GIWNOt11 ECtiVig Nt YJST C3YPL1 W.. LOCAL CCLS. 2. IR[ SUIE PORN SURLY A US NITN EOUPIIENT IAIQPLAt(. 1. Lew YC. ?L. k 1FNG 10 BE w:. 2 kg G. 11N1wr CONDKTra. 4. USE COIPIN CONLICTORS MAT. S. POVAIRO RLAI WCna PV•* K AfTACN10 10AMA COITAL ION. S1C11011• ! 10 (011011 1*1 INTO AM NAN0.111. I. It 001 SSA MO. MA COBALT ARIRPRWIE AN/EIS maw To 11f AIN AO III LAIL T. 11R1*0 S 4 MO w1 Nt. AWE 111(110., CONNECT 1011 ALT IT 210 o $1c01111TAIR ME USEOel Tl( NEARED COP COMMOII P0610 TOELECIIK IEATIN0 EILKI1S. 1f 210IAOMAGN CONTACTORS ME MT IMO. T1EO PILO Comma's IONS 10 .2 MN R7 CM K 01111 OvOOPAIUE. 0. CONNECT is 10111M1ER 11 0.0.011T MS T CO1ECTION. NEAT PUMP 0.0. SECTION N ROME 910a TO POMER SUPPLY{ PER LOC* SUPPLY{ CDOES REQUIRED ��_ CDR 3 PR - 001•' 001'.2 [900 ®uUUMUU INTER•COYPONENT MIRING 24 v. FACTORY LINE Y. WIRING 24 y. 1 F IELD LINE Y.f WIRING An WIRE REQUIRED FOR 3 PH t0 PDNER SUPPLY PER LOCAL CODES 4AS DEC' INED IN FIELD WIRING TABLE SUM. NTR. CONTROL 801 PM •A I•Pr SEE NOTE 5 AIR HARMER NOTES G47 1 _..1 218131071 R 2.1 From DWq.21E1131071 Rall2 MODEL NO. A B C D E F O H J K L Flow Control Gas Una BRAZE Uq. Una BRAZE TWE016C14 ' 43 15.57 21.5 19.5 20.28 21.63 3.62 1.89 8.45 3.65 5.77 FCCV 5/8 1/4 TWEQ24C14 3/4 5/18 -. TWE030C14 718 3(8 TWE036C14 1WE042C14 r 45.00 17.57 23.5 21.5 22.28 23.63 3.21 1.89 6.45 4.65 6.77 TWE048C14 51.75 24.32 1.48 7.70 1 -1/8 3/8 1WE060CID15 57.90 30.47 1.48 7.70 TXVB MINIMU AUNT(' CLEARANCE TABLE TO COMBUSTIBLE MATERIAL (REQUIRED) SERVICE CLEARANCE (RECOMMENDED) SIDES FRONT BACK NET DUCT OUTLET DUCT 0 b b o b n b 'FIRST 3 FT. OF OUTLET OUCT Mel ELECTRIC HEATERS ARE IGTAILED. .11 Al POTION VOW ter» :047 GAS tail • ' sap T • LOW • VOI.TAGS 'Lull • !AT MS OUTLINE DRAWING FOR TWE018 -048C; TWE060D ^vr vr�: s•<aa'x�f.rs�' >......., y......« ""_fi.5;.:A:l�'...:t:'y'-:'�'e� t l0 K 6 MI NOT USED 14141 314 -14 TAPERED PIPE THREAD AIRFLOW 4 . HORD. MONT NOM LIFT ♦ AIRFLOW SUR RACE NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. From Owp.210800008 Rya 3 TWE 18 Through 06(' ; Convertibility ' SIX (6) WAY CONVERTIBILITY One Gait • 4 Applications (CanreAWN lot Easy Conversion to Opposite side Access movement s �e C • APO 4kilo Wass r s ell Met ail o. Isllr 1A' 2 sae /HetweA w wr.s.. a+ � .......... 4 Irrww.e.. V.+w ti OM*Me0or •CO M AM radio s I. crow. NO. Ono Ar.o L V..I.Irtarn 3. la....se W• I.s Arm) i I.i.wM MO. e.rA..r.l a Harman+• Paw Aso* awalaalhmi away lrs s pM d wrwM soeis wparwsaa, r worm Ma *a r *Ow M umilloa• Orr . - salmi nM .;: + , Tedirkal Literature Printed In U.S.A. The Trane Company Unitary Products Group 6200 Troup Highway Tyler, TX 75707 -9010 . An American- Standard Company 16 Mechanical ^t Specifications GENERAL — Blower coil units shall be completely factory assembled including coil, condensate drain pan, fan, motor, filters and controls in an insulated casing that can be applied in horizontal or vertical configuration. The "F' model indicates an "Air -Tits" model with 4.2 "R" valve insulation and additional sealing system. This new line of TWE -C Air handlers provides exclusive compact size combined with simple 6 -Way convertibility in sizes up to 5 Tons. The unit ships in the right hand horizontal configuration and converts to vertical upflow just by standing the unit on end. No tools required. Simple coil rotation provides downflow and horizontal left applications. The 6 -Way convertibility provides you inventory benefits and service /installation flexibility. The simple conversion provides opposite side access for installation and service. These Air Handlers enjoy the best reputation in the industry. Superior airflow, great sound level, reliability and performance are responsible for the industry leadership. We are not about to give up such top performance. Units shall be UL listed. CASING — Units shall have rugged sheet metal and steel frame construction and shall be painted with an enamel finish. Casing shall be insulated and knockouts shall be provided for electrical power and control wiring. REFRIGERANT CIRCUITS — The TWE units shall have a single refrigerant circuit. TWE018-048C refrigerant circuit shall be controlled by a flow control check valve (FCCV) TWE060C. Refrigerant circuit shall be controlled by a factory- installed thermal expansion valve. COIL - Aluminum fin surface shall be mechanically bonded to 3/8 inch OD copper tubing. Coils shall be factory pressure and leak tested. FAN — Forward curved, dynamically and statically balanced with 3 speed direct drive shall be standard, fan motor bearing shall be permanently lubricated. CONTROLS — Low voltage terminal board, fan contactor, and plug in module for accessory electric heat control shall be included. TWE models shall also indude check valves. FILTERS — Filters shall be included as standard, one inch low velocity semi - permanent type (except 5 ton - washable filter). ACCESSORIES Electric Heaters — Shall be available in a wide range of capacities and voltages with various staging options, and plug - in control wiring. Heaters fit inside internal compartment Library Product Section Product Model Literature Type Sequence Date File No. Supersedes Product Literature Spit Systems TWE 1Sb -5Ton Data Catalog 1 March 1996 PL- UN- SIS- TWE -D-1 W96 TWE -D-1 W93 P.I. o O N W }} - u- < N d W • Zt, • O . • O • 'WW O Z4 U N ` O . TRANEm split system Cooling RECEIVED Product Data CITY OF TUKVOLA 0P-1 7. 9 2101 PERMIT CENTER TTA030 -072C 1 -6Ton TTA -D -2 PUB. NO. 22-1641-03-129k (EN) Moi or 1).• tr. <;4: iJ i�`istSrl:)r„i[:ii [; kk.114 i >a :1.C.Ot1.`s:�. {, {'t }:t:C.::.k Split System Cooling Units ... Designed With Your Needs In Mind. TTA split systems represent a new approach to designing products for The Trane Company. The design team's mission is "... to bring a system to the marketplace that will meet your job requirements every time" ... And at a competitive price. Trane's experienced design team used the newest computer technology and an entirely new manufacturing process to develop a new standard in split systems. Couple the Trane reputation for quality and reliability in split system air conditioners with improvements in efficiency, flexibility and installation ease . and you have systems that prove "It's Hard to Stop a Trane". z 0 American Standard Inc. 1906 MINE" General Features Manufacturing Control Trane's exclusive control over the design and manufacturing of all major components is unique in the industry. This approach assures us total control over both the quality and reliability of these components. It also allows us to custom match components to deliver the best in split system performance. Designing the Details Careful attention was given to designing the details — from control wiring to the access panels. TTA units feature time- saving color -coded wiring and removable panels which allow complete access to all major components and controls. All outdoor units feature external high and low pressure gauge port connections and service valves for easy diagnosing and servicing of the unit are provided. UL Listed and CSA Certified Trane meets or exceeds all nationally recognized agency safety and design standards. Each unit is UL designed, approved, and labeled in accordance to UL Standards: UL 1995, including approval for use in Canada. Each unit is rated in accordance with ANSI ARI Standard 21W240 and 270. 2 Pub. No. 22- 1641.03.1296 (EN) (-) Contents Feature Summary Th Features and Benefits Optional Equipment Low Outdoor Ambient Cooling Standard Capacity Rating Conditions • Selection Procedure Model Number Nomenclature • General Data TTA030C3/400A 4.411TTA036C3/400A TTA042C3/400A TTA048C3/400A TTA060C3/400A TTA072C3/400A Ratings With Auxiliary Devices Electrical Data Dimensions Mechanical Specification Options 3 41) INANE" 7 ) • • • Features and Benefits • Trane Climatufr compressor • Internal pressure relief valve • Ball bearing fan motors • Spine Fin Tm outdoor coil • Direct drive propeller fan • External crankcase sump heat • Refrigerant line filter-drier • Motor contactor • Decorative steel top • Outside pressure taps for refrigerant system check • Silver-gray color powder paint resists corrosion & rust • Operating charge of HCFC-22 • Low pressure switch • Vertical outdoor air discharge • Service valves • Low ambient cooling to 55°F. as manufactured • Low ambient cooling with accessory AY28X079 to 40°F. FCCV, 30°F TXV indoor refrigerant control • Low ambient cooling to 0°F with accessory BAYLOAM100A or BAYLOAM101A • 5-year compressor limited warranty • Optional extended warranties Pub. No. 22- 16414)3.1296 (EN) Low Ambient Cooling FCCV Accutron Thermal Expansion Valve (TXV) Features and Benefits OPTIONAL EQUIPMENT OPTIONAL EQUIPMENT FOR CONDENSING UNITS (Check mark V] indicates accessories included). Indoor Thermostats — 1 -Step Heat/1 -Step Cool (Horz.) AY28X092 [ ] Ill 1 -Step Heat/1 -Step Cool (Vert.) BAYSTAT305 [ ] 1 -Stage Heating/Cooling® BAY28X182 [ ] 2 -Stage Heating/Cooling® BAY28X183 [ ] Cooling Only With Fan Switch BAYSTAT304 [ ] Sub -base (Auto. /Man. Changeover) BAY28X183) BAY28X184 [ ] Sub -base (Man. Changeover) BAY28X182, 1830 BAY28X185 [ ] Sub -base (Auto. Changeover) BAY28X182, 1830 BAY28X187 [ ] Outdoor Thermostat TAYSTAT250A [ ] Locking Thermostat Cover Room Thermostats® BAY28X190 [ ] Electronic Head Pressure Control TTA030 -072C30 BAYLOAM100A [ I Electronic Head Pressure Control TTA030 -072C4® BAYLOAM101A [ I Evaporator Defrost Control AY28X079 [ ] 5 or 7 Minute Delay Relay® BAY41X171A [ ] DPDT Fan & Electric Heat Relay All Systems/2 Speed Motor BAY24X042 [ I 77 VA Transformer 230V/24V TTA030 -072C3 BAYTFMR003A [ ] 77 VA Transformer 460V/24V TTA030 -072C$ BAYTFMR004A [ ] Vibration Isolators° BAYISLT 1 CO ( j O Requires Sub -base 0 Not for use with programmable thermostats O Requires BAY24X042 relay kit when used with electric heat 0 Not approved for use with hot gas by-pass kits 0 Speci>icatty designed for electric heat applications (instant on font BRAZED TUBING REFRIGERANT LINE SETS (All Suction Lines are Insulated.) 5/8' ODM (90° bend one end), 5/8' and 1/4' tubing. TAYREFLN1_' [ I 3/4' ODM (90° bend one end), 3/4' and 5/16' tubing. TAYREFLN2_' [ ] 7/8' ODM (90° bend one end), 7/8' and 3/8' tubing. TAYREFLN3 [ ] 1 -1/8' ODM (90° bend one end), 1 -1/8' and 3/8' tubing TAYREFLN4_* [ ] 'Line lengths: 15, 20, 25, 30, 40 & 501t. Insert desired line length in catalog number at right tor the complete number. Example: TAYREFLN220 LOW OUTDOOR AMBIENT COOUNG A.R.I. STANDARD CAPACITY RATING CONDITIONS A.R.I. STANDARD 2101240 RATING CONDITIONS— Cooling 80•F D.B., 6TF. W B. air entering indoor coil, 95 °F D.B. air entering outdoor coil. A.R.I. STANDARD 270 RATING CONDITIONS- (Noise rating numbers are determined with the unitt In cooling operation. Standard Noise Rating number is at 95 °F. outdoor air. As Evaporator Manufactured Defrost Control 55 °F 40 °F 45 °F 30 °F 1 1 2 T T PRODUCT TYPE Split Cooling - TTA, TTN, TTR, TTS, TTX Split Heat Pump - TWA, TWN, TWR, TWS, TWX Package Cooling - TCC, TCH, TCD, TCX, TCM Package Heat Pump - WCC, WCD, WCH, WCM, WCX, DCX Air Handler - TWV, TWH, TWE Gas/Electric - YCC, YCD, YCH, YCX Coils TXA, TXC, TXE, TXF, TXH, TXM, TXS SPLIT SYSTEM COUPLING SYSTEMS 1 -5TONS 7 - Quick- Attach Selection Procedure Model Number Nomenclature 3 4 5 6 7 8 9 A 0 4 2 C 3 0 PRIMARY CAPACITY Example: 042 = 42 MBTUH = 3.5 Tons 10 11 0 A POWER SUPPLY & FUEL MAJOR DESIGN MODIFICATION MINOR DESIGN MODIFICATION SECONDARY FUNCTIONS Gas/Electric - Gas Heating Furnaces - Cooling Airflow Air Handlers OUTDOOR UNIT CD POWER CONNS. - V/PHIHZ MIN. BIRCH. CIR. AMPAC(TY O BR. CIR. 't MAX. (AMPS) PROT. RIG.' RECMD. (AMPS) NOISE RATING (DECIBELS) O COMPRESSOR NO. USED • NO. SPEEDS VOLTS/PH/HZ R.L. AMPS • L.R. AMPS BRCH. CIR. SELEC. CUR. AMPS OUTDOOR FAN - TYPE DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM flf 0.0 IN. W.G. O NO. MOTORS . HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS OUTDOOR COIL - TYPE ROWS - F.P.I. FACE AREA (SO. FT) TUBE SIZE (IN.) REFRIGERANT LBS. - R -22 (0.0. UNIT) OO FACTORY SUPPLIED UNE SIZE • IN. 0.0. GAS O UNE SIZE - IN. 0.11 LAO.O FCCV - RESTRICTOR ORIFICE SIZE DIMENSIONS OUTDOOR UNIT - CRATED (IN.) UNCRATED WEIGHT SHIPPING (LBS.) NET (LBS.) EXPANSION TYPE RATINGS (COOUNG) O BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CF1i ) SYSTEM POWER (KW) SEER (BTUIWATT -HR.) EXPANSION TYPE RATINGS (COOUNG) O BTUH (TOTAL) STUN (SENSIBLE) • INDOOR AIRFLOW (CFM) SYSTEM POWER SEER BTWWATT•HR.1) • EXPANSION TYPE RATINGS (COOLING) O STUB (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFII) SYSTEM POWER (KW) SEER (BTUAMATT4IR.) 30600 21000 1000 3.33 10.15 29000 19200 900 317 t 10.20 'SM pp. 20 Ix a o m b i m i o n s wwiAii y Ds U.. Pub. No. 22.1641.03.1293 (vG 1 :4 ; j . ': • TTA030C300A 200/230/3/60 14 20 20 80 CLIMATUFP 1 -1 200/230/3160 10.75 10 PROPELLER 18.1 DIRECT - 1 1944 1 -1/4 1075 200/230/1(60 1.7 SPINE FIND 1 - 24 1222 3/8 4 -LBS., 10-01 YES 3/4 5/16 0.067 H X W X D 25 X 26-1/2 X 30 SEE OUTUNE DWG. 161 152 CONDENSING General Data 30600 21000 1000 333 10.15 TXC017S3 11H033A4 TXV•N8 CHG TO 67 31200 29600 ' • 22700 . 20200 $ .-:!'.1000 1125 ,,:' ; ;.9.92 :A;:'3.22 ; F • t.x .10.66 •: x ' ' TTA030C400A 460/3/60 7 15 15 80 CLIMATUFP 1 -1 460/3/60 5 -38 5 PROPELLER 18 -1 DIRECT - 1 1944 1 -1/4 1075 460/1/60 0.80 SPINE FIND 1 - 24 1222 3/8 4 -LBS., 10-01 YES 3/4 5/16 0.067 H X W X D 25 X 26-1/2 X 30 SEE OUTLINE DWG. 161 152 UNIT WITH COOLING TXA031C4 TXCO31C4 TXCO31E5 TXCO31S3 FACT INS 67 FACT INS 67 TXV-8 TXV•NB 30400 21000 1000 325 10.10 30200 20600 1000 323 10.55 " • -• ?: '''''CONDENSING' UNIT WITH AIR • HAND . 4.1 f '; " ...a.,rz:: • =`:,`, - - MINIM `•1WE024P13 1WEQ30CMINIM • • TWE031E13 FACT INS 67 TXV-NB 7X1/44B 29400 19700 . 960 314 10.40 . 7 TTA030C3 /400A O CERTIFIED IN ACCORDANCE WITH A.R.I. STANDARD 210/240. O RATED IN ACCORDANCE WITH A.R.I. STANDARD 270. SPLIT SYSTEM O CALCULATED IN ACCORDANCE WITH NATL ELECTRIC CODE. SUITABLE FOR USE WITH HACR CIRCUIT BREAKERS OR FUSES. O STANDARD AIR • DRY COIL - OUTDOOR 0 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT NAMEPLATE AND SERVICE INSTRUCTION. © MAX. LINEAR LENGTH 80 FT; MAX. UFT - SUCTION 60 FT; MAX. LIFT • LIQUID 60 FT. MAX. LENGTH OF PRECHARGED TUBING 50 FT FOR GREATER LENGTH REFER TO REFRIGERANT PIPING MANUAL PUB. NO. 32-3C09. 90200 20900 1025 3.06 • 11.00 l C� S TXCO36E5 TXV•B 31600 23000 1125 3.36 10.10 TXCO36S3 TXV•NB 31200 72100 1125 3.32 10.65 TXCO37E5 TXV-8 31600 23000 1125 3.36 10.10 TWE036C14 TWE03IP13 . TWE037E13 CND TO 67 TXV•NB TXVM 30600 30100 30330 21500 21700 21200 1125 1125 1000 3.34 3.30 3.03 10.05 10.25 11.30 EXPANSION TYPE RATINGS (COOLING) 0 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) SEER (BTUNVATT -HR.) EXPANSION TYPE EXPANSION TYPE RATINGS (COOLING) 0 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CR4) SYSTEM POWER (KW) SEER (BTUWVATT.HR.) EXPANSION TYPE ' • TUY100RIV4A +TX0164S3 RATINGS (COOLING)°, BTUH (TOTAL) :.• ;;;;;,,.; .. BTUH (SENSIBLE) 'T INDOOR AIRFLOW (tM) SYSTEM POWER (KW) SEER (BTUIWATT.IR.) 'See paps 20 br oan6YWlons wN1 Auxiliary Devices TXV413 30800 • 21000 875 3.00 11.50 General Data CONDENSING UNIT WITH AIR HANDLERS TWE040E13 TWE042C14 TWE042P13 TWG025A14 TWG030AI4 TW0006A14 TWHO24B14 TXV.NB CHG TO 67 TXV.NB CHG TO 67 CHG TO 67 CHG TO 67 CHG TO 67 32400 30800 30800 27000 28600 29800 29400 23800 22100 22300 17600 19100 20800 20000 1050 1125 1125 875 1000 1115 900 3.09 3.37 3.33 2.93 3.14 3.27 3.16 11.85 10.05 10.35 10.00 10.00 10.00 10.30 1WH030814 -8 1WHO361314 TWV025B14 TWV030B14 TWV0361114 CHG TO 67 CHG M67 CHG TO 67 FACT INS 67 CHG TO 67 RATINGS (COOLING) 0 BTUH (TOTAL) 30400 31400 29200 30400 31200 BTUH (SENSIBLE) 21500 23300 19800 21500 23100 INDOOR AIRFLOW (CFM) 1000 1125 900 1000 1125 SYSTEM POWER (KW) 3.25 3.39 3.21 329 3.41 SEER (BTU/WATT-HR.) 10.30 10.15 10.00 10.20 10.05 TTA030C3 /400A CONDENSING UNIT WITH FURNACES & COILS TDD060R9V3 TDDOIOR9V3 TDDOIOR9V3 TD0080R9V3 TDDIOOR9V5 TDD1COR9V5 TDD100R9V5 +TXCO31E5 +TXCO31S3 +TXCO36E5 +TXCO36S3 +TXCO37E5 +TXCO37S3 +TXCO54E5 EXPANSION TYPE TXV-8 TXV.NB TXV-B TXV.NB TXV-B TXV.NB TXV-B RATINGS (COOLING) 0 BTUH (TOTAL) 30400 30400 31200 31200 31400 31400 31200 BTUH (SENSIBLE) 20800 20800 21500 21500 22000 22000 22000 INDOOR AIRFLOW (CFM) 950 950 950 950 975 975 975 SYSTEM POWER (KW) 3.04 3.04 3.06 3.06 3.05 3.05 3.03 SEER (BTU/WATT -HR.) 11.20 11.15 11.40 11.50 11.60 11.60 11.40 TUDOBOR9V3 TUD060R9V3 TUD080R9V3 TUDOIOR9V3 TUD100R9V5 T1.1D100R9V5 TUD100R9V5 +TXCO31E5 +TXCO31S3 +TXCO36E5 +TXCO36S3 +TXCO37E5 +TXCO37S3 +TXCO54E5 TXV-B TXV.NB TXV-B TXV.NB TXV•8 TXVNB TXV-B 30600 30600 31400 31400 31400 31400 31200 21200 21200 22000 22000 22100 22100 22100 975 975 1000 1000 1000 1000 1000 3.08 3.06 3.11 3.11 3.06 3.06 3.06 11.20 11.15 11.35 11.35 11.50 11.50 11.40 TUYOIORVV3A TUY090RBV3A TUYO11OR9V3A TUYOIORIV3A TUY100RIV4A TUY100R9V4A TUY100R9V4A +TX0331E3 +TXCO3153 +TXCO3sE5 +TXCO3es3 +TXCXg7E5 +TXCO37S3 +TXCO54E5 EXPANSION TYPE TXV•B TXVNB TXVFB TXV.NB TXV.B TXVNB TXV•B RATINGS (COOLING) 0 • 1311J11 (TOTAL) 30000 30000 30600 30600 30800 30800 30800 STUN ( SENSIBLE) 20000 20000 20600 20600 20900 20900 21000 INDOOR AIRFLOW (CR4) 850 850 860 850 875 875 875 SYSTEM POWER (KW) 302 302 3.01 3.01 2.99 2.99 3.00 SEER (BTWWATFHR.) 11.15 11.15 11.35 11.35 11.55 11.55 11.50 Pub. Na 22- 1841-03.1296 (EN) 4 14N YJPTRl4 ""`FI'h��.+'t +�< ».1... a1S.+ OUTDOOR UNIT OO O POWER CONNS. - V/PH/HZ MIN. BRCH. CIR. AMPACFTY O BR. CIR. 1. MAX. (AMPS) PROT. RTG. RECMD. (AMPS) NOISE RATING (DECIBELS) O COMPRESSOR NO. USED • NO. SPEEDS VOLTS/PHIHZ R.L. AMPS - L.R. AMPS BRCH. CIR. SELEC. CUR. AMPS OUTDOOR FAN - TYPE DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM 0 0.0 IN. W.G. O NO: MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS OUTDOOR COIL - TYPE ROWS - F.P.I. FACE AREA (SO. FT.) TUBE SIZE (IN.) REFRIGERANT LBS. - R •22 (0.0. UNIT) O FACTORY SUPPLIED UNE SIZE - IN. 0.0. GAS UNE SIZE • IN. O.D. UO.O FCCV - RESTRICTOR ORIFICE SIZE DIMENSIONS OUTDOOR UNIT - CRATED (IN.) UNCRATED WEIGHT SHIPPING (LBS.) NET (LBS.) EXPANSION TYPE RATINGS (COOUNG) O BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) SEER (BTU/WATT•HR.) EXPANSION TYPE RATINGS (COOUNG) O STUN (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) SEER (BTU/WATYHA.) 190 181 CONDENSING =BAUMACC FIXED ORIFICE 31200 22000 1100 3.70 10.10 EXPANSION TYPE CHG TO 71 RATINGS (COOLING) 0 STUN (TOTAL) 34800 BTUH (SENSIBLE) . 23000 INDOOR AIRFLOW (CPN) .1100 SYSTEM POWER (KW) :: < 372 SEER (BTU/WATT -HR.) • 10.10 TXA019C4 CHG TO 71 37400 26800 1350 9,98 10.15 'Sa page 20 ix o nbi r wIlkNifikry Oakes. Pub. Na 22. 1641.03.1296 (ET1) TTA036C300A 200/230/3/60 17 25 25 80 CLIMATUFP 1 -1 200/230/3160 12. 101 12 PROPELLER 18.1 DIRECT - 1 2175 1 -1/4 1075 200/230/1/60 1.7 SPINE FIN"' 1.24 1222 3/B 5 -LBS., 12 -0Z. YES 7/8 3/8 0.071 H X W X O 25 X 26.12X30 SEE OUTLINE DWG. TXA031C4 TXA035C4 FACT INS 71 General Data 34800 23000 1100 3.72 10.15 CHG 1071 37400 28800 1950 . 9.96 1020 TTA036C400A 460/3/60 7 15 15 80 CLIMATUFP 1 -1 460/3/60 5.51 5 PROPELLER 18 -1 DIRECT • 1 2175 1 -1/4 1075 460/1/60 0.8 SPINE FIN"' 1-24 12.22 3/8 5 -LBS., 12 - 02. YES 7/8 3/8 0.071 H X W X D 25 X 26-1/2 X 30 SEE OUTLINE DWG. 190 181 UNIT WITH COOLING 34800 24000 1200 3.76 10.15 34200 22000 1100 3.70 . 10.10 9 O CERTIFIED IN ACCORDANCE WITH AJU. STANDARD 219 OO RATED IN ACCORDANCE WITH A.R.I. STANDARD 270. SPLIT SYSTEM O CALCULATED IN ACCORDANCE WITH NATL ELECTRIC CODE. SUITABLE FOR USE WITH HACK CIRCUIT BREAKERS OR FUSES. O STANDARD AIR - DRY COIL • OUTDOOR O THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT NAMEPLATE AND SERVICE INSTRUCTION. O MAX. LINEAR LENGTH 80 FT; MAX LIFT • SUCTION 60 FT; MAX. ' LIFT - LIQUID 60 FT. MAX LENGTH 2)F PRECHARGED TUBING 50 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING MANUAL PUB. NO. 32-3009. 34200 22000 1100 3.70 10.10 34800 23000 1100 3.72 10.10 TTA036C3 /400A COILS CC88JEA4ACC CCBB42A4ACC CUBA36A4ACC CUBB36A4ACC FIXED ORIFICE FIXED ORIFICE FIXED ORIFICE FIXED ORIFICE 34600 23000 1100 3.72 10.15 TXA036C4 TXA037C4 TXA042C4 TXA043C4 FACT INS 71 FACT INS 71 CHG TO 71 CHG 10 71 94200 36400 35800 36400 36800 22000 . 24800 24400 25300 26100 1100 ;:' 1200 ;`:' < 1200 1250 1350 3.70 a:.- :. 391 .:.ty,M;, r , 981. 3.87 3.94 10.10 1025 i"/ 10.20 1020 10.15 • T7(CO30C4 7X1303104 TX0001E5 TX003SC4 CHG TO 71 CHG TO 71 TXV-8 FACT INS 71 35800 23800 1100 3.75 10.40 CUBB42A4ACC TXA030C4 FIXED ORIFICE CHG TO 71 34800 24000 1200 3.76 10.15 34200 22000 1100 3.70 10.10 34200 22000 1100 3.70 10.10 11A048C4 1216 T071 37400 28800.; 1350 • ' 10.15 TXCO3SC4 FACT INS 71 38400 24800 1200 3.91 1025 •st ' ,:. .> ,..ls ., .�..Si�z,i+� »:J i. }:. , s:... .5 , .,.. ix it U t) O; • 1n 0: W W. J (0 >L'. W O; LL Q • • r. U • Z O N' ' W UJ U • W W Z .. • O 1- .Z EXPANSION TYPE RATINGS (COOLING) O BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) SEER (BTU/WATT -HR.) EXPANSION TYPE RATINGS (COOLING) O BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) SEER (BTU/WATT-HR.) EXPANSION TYPE RATINGS(COOLING)0 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) SEER (BTUIWATT -HR.) EXPANSION TYPE RATINGS (COOLING) 0 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) SEER (BTUNVATT.HR.) EXPANSION TYPE RATINGS (COOUNG) O' STUN (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW SYSTEM POWER (KW) SEER (8TWWiUT•Hi.) EXPANSION TYPE RATINGS (COOLNG) a, : BTUH (SENSIBLE) INDOOR AIRFLOW (CFA) SYSTEM POWER (KW) SEER (BTUNIATI:HR.) 'S.. page 20 for oombirlorrt *i Ai Lary Data. General Data CONDENSING UNIT WITH COOLING COILS TXCO36E5 TXCO36S3 TXCO37C4 TXCO37E5 TXV•B TXV-NB FACT INS 71 TXV•B 36600 36600 35800 36600 25300 25300 24400 25300 1200 1200 1200 1200 3.81 3.81 3.81 3.81 10.50 10.80 10.20 10.50 TXCO46C4 CHG TO 71 TXC049C4 TXCO50C4 CHG TO71 CHG TO71 37400 37400 37400 26800 26800 26800 1350 1350 1350 3.96 3.96 3.96 10.15 10.15 10.20 CONDENSING UNIT WITH AIR HANDLERS 1WG037A14 TWH030814.8 FACT INS 71 CHG TO 71 FACT INS 71 CHG 10 71 FACT INS 71 34800 23100 1200 3.78 10.00 35400 24300 1125 an 10.35 TXVB TXVB 36000 36800 •24200 25100 1100 1125 3.64. 3.64 11.00 1120 36600 25700 1200 189 10.50 10 TTA036C3 /400A TXCO37S3 TXV NB 36600 25300 1200 3.81 10.80 TXC042C4 TXC043C4 CHG TO 71 CHG TO 71 36400 36800 25300 26100 1250 1350 3.87 3.94 1020 10.15 TXCO54E5 TXCO54S3 '004033A4 TXH041A4 TXV-B TXV-NB CHG TO 71 CHG TO 71 37000 37000 34600 37400 26900 26900 23000 26400 1350 1350 1125 1350 3.89 3.89 3.74 3.96 10.25 10.70 10.15 10.25 TWE030C14 TWE030P13 r 4E031E13 7.VE036C1s r‘:4E036P13 TWEO37E13 T44E040E13 CHG 10 71 TXV-NB TXV FACT INS 71 TXV TXV TXV 33000 34000 34800 35600 35600 36200 38500 21200 21800 22900 23800 24200 24800 28400 950 950 1050 1200 1200 1200 1275 3.59 3.60 3.55 3.83 3.81 3.60 3.67 10.20 10.50 10.95 10.35 10.50 11.25 11.80 1WE042C14 TWE042P13 TWE04IC14 -8 TWEO48P13 TWE065E13 TWG030A14 TWG036A14 CHG TO 71 TXV-NB CHG TO 71 TXV-NB TXVNB CHG TO 71 FACT INS 71 35800 36800 37400 36800 38500 32800 34600 24400 26300 26500 27600 26700 21300 22800 1200 1350 1350 1350 1075 1100 1150 3.85 3.91 4.02 3.74 3.65 3.57 3.84 10.25 10.50 1025 10.45 11.90 10.00 10.00 TW14036814 TWV030814 1WV001814 35200 24100 1125 183 1020 36400 25500 1200 191 . 1030 CONDENSING UNIT WITH FURNACES & COILS TDONOIIM T130080RWY3 TD0010RW3 TD01001MVS T00100A1115 1130111110115 TD0100RN5 +TXCOMB rTXC0118 4TXC008S3 +TXC007E5 +TX0007S3 +TXCO54E5 +TX00515,1 TXV-N8 nope TAWS TXVB TXV#18 36800 37200 37200 37000 37000 25100 25700 25700 25900 25900 1125 1175 1175 1175 1175 3.64 3.61 3.61 , 3.59 359 11.20 11.60 11.50 1125 11.50 Pub. Na 22- 1641-03.1298 (EN) EXPANSION TYPE 'See page 20 1or cambinaDons with Au i ary Devices. RATINGS (COOLING) 0 BTUH (TOTAL) 36400 36400 BTUH (SENSIBLE) 24800 24800 INDOOR AIRFLOW (CFM) 1050 1050 SYSTEM POWER (KW) 3.55 3.55 SEER (BTU/WATFHR.) 11.55 11.50 General Data CONDENSING UNIT WITH FURNACES & COILS � IYi00R9V4A TUYIOOR9V4A +TXCO54E5 +TXCO54S3 TXV-B TXV-NB TTA036C3 /400A TUDOIOR9V3 TUD080R9V3 TUDOIOR9V3 TUDOIOR9V3 TUD100R9V5 TUD100R9V5 TUD100R9V5 +TXCO31E5 +TXCO36E5 +TX0W6S3 +TXC064S3 +TXCO37E5 +TXCO37S3 +TXCO54E5 EXPANSION TYPE TXV.B TXV-B TXV-NB TXV-NB TXV-B TXV-NB TXV-B RATINGS (COOUNG) O BTUH (TOTAL) 36200 36800 36800 36600 37200 37200 37000 BTUH (SENSIBLE) 24400 25500 25500 25500 25900 25900 26000 INDOOR AIRFLOW (CFM) 1100 1200 1200 1175 1200 1200 1200 SYSTEM POWER (KW) 3.55 3.76 3.76 3.68 3.65 3.65 3.65 SEER (BTU/WATT -HR.) 10.85 10.90 10.90 11.05 11.50 11.35 11.35 TUD100R9V5 TUYOIOR9V3A TUYOIOR9V3A TUYOIOR9V3A TUYOIOR9V3A TUY100R9V4A TUY100R9V4A • +TXCO54S3 +TXCO31E5 +TXC001S3 +TXCO36E5 +TXCO36S3 +TX0037E5 +TXCO37S3 EXPANSION TYPE TXV-NB TXV-B TXV-NB TXV-B TXV-NB TM TXV-NB RATINGS (COOLING) 0 BTUH (TOTAL) 37000 35600 35600 36400 36400 36600 • 36600 BTUH (SENSIBLE) 26000 23600 23600 24300 24300 24700 24700 INDOOR AIRFLOW (CFM) 1200 1050 1050 1050 1050 1050 1050 SYSTEM POWER (KW) 3.65 3.60 3.60 3.62 3.62 3.55 3.55 SEER (BTU NATT.FIR.) 11.35 11.10 11.05 11.25 11.20 11.60 11.55 TRANE" OUTDOOR UNIT 00 TTA042C300A TTA042C400A POWER CONNS. - V/PH/HZ 2001230/ 3 460/ 3/60 MIN. BRCH. CIR. AMPACTTY 0 20 10 BR. CIR. 1 MAX. (AMPS) 30 15 PROT. RTG. RECMD. (AMPS) 30 15 NOISE RATING (DECIBELS) 0 80 80 COMPRESSOR CUMATUFP CLIMATUFP NO. USED• NO. SPEEDS 1 -1 1 -1 VOLTS/PH/HZ 200/230/,V60 46013/60 R.L AMPS - LA. AMPS 14.9 -101 6 -51 BRCH. CIR. SELEC. CUR. AMPS 14.4 7 OUTDOOR FAN - TYPE PROPELLER PROPELLER DIA. (IN.) • NO. USED 18.1 18 - 1 TYPE DRIVE • NO. SPEEDS DIRECT • 1 DIRECT - 1 CFM 0 0.0 IN. W.G. CD 2238 2238 NO.MOTORS - HP 1 -1/4 1 -1/4 MOTOR SPEED R.P.M. 1075 1075 VOLTS/PH/HZ 200230/1/60 460 /1/60 FL AMPS 1.7 0.8 OUTDOOR COIL - TYPE SPINE RN"' SPINE FIN"" ROWS - F.P.I. 1.24 1.24 FACE AREA (SO. FT.) 16.84 16.84 TUBE SIZE (IN.) 3/8 3/8 REFRIGERANT LBS. - R -22 (0.0 UNfl 0 6 -LBS.. 14-02. 6-LBS.. 14-0Z FACTORY SUPPLIED ''_S YES LINE SIZE - IN. O.D. GAS 0 7,2 713 UNE SIZE - IN. O.D. LIO. 0 3/8 3/8 FCCV - RESTRICTOR ORIFICE SIZE 0.080 0.080 DIMENSIONS H X W X D H X. W X OUTDOOR UNIT - CRATED (IN.) 33-1/4 X 26-1/2 X 30 33.1/4 X 26-1 30 UNCRATED SEE OUTLINE DWG. SEE OUTLIN WEIGHT SHIPPING (LBS.) 211 NET (LBS.) 200 i.i.C.4 i .1.• • 'MA0I0CS EXPANSION TYPE - ' TXV•B RATINGS (COOUNG) 0 a : .: <= BTUH (TOTAL) : {: ' 45000 BTUH (SENSIBLE) :.31700 INDOOR AIRFLOW (CFM); :; ?':' }° `. : 1575 SYSTEM POWER (KW) •^, =:,`s: y - .4.88 4.44 SEER (BTUUWAIT•HR.) ---..ti: „ 10.10 10.00 'Sea papa 20 and 21 bt oo J !,Jolla will Aua DON= y DON , .. General Data CONDENSING UNIT ITH COOLING COILS 1X00051'.4 CHG TO 80 • 10000 24900 1100 12 CHG TO CO TXV•B TTA042C3 /400A O CERTIFIED IN ACCORDANCE WITH A. ANDARD 210/240. 0 RATED IN ACCORDANCE WITH a STANDARD 270. SPLIT SYSTEM O CALCULAT D IN ACCORDANCE WITH NATL ELECTRIC CODE. SUITABL FOR USE WITH HACR CIRCUIT BREAKERS OR FUSES. O STAN RD AIR - DRY COIL - OUTDOOR 0 THIS'(IALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE U NAMEPLATE AND SERVICE INSTRUCTION. 0 AX. LINEAR LENGTH 80 FT; MAX. UFT - SUCTION 60 FT; MAX. FT - LIQUID 60 FT. MAX. LENGTH OF PRECHARGED TUBING 50 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING MANUAL PUB. NO. 32-3009. CCSB42A4ACC CC8841A4ACC C48A4ACC CUBB42A4ACC CUBB48A4ACC CUBC48A4ACC TXA03SC4 EXPANSION TYPE RATINGS (COOUNG) 0 BTUH (TOTAL) 42000 42500 44000 42000 42500 44000 40000 BTUH ( SENSIBLE) 27100 27800 30400 27100 27800 30400 24900 INDOOR AIRFLOW (CFM) 1200 1250 1575 1200 1250 1575 1100 SYSTEM POWER (KW) 4.57 482 4.81 4.57 4.62 4.81 4.44 SEER (BTU/WATT•HR.) 10.05 10.05 10.00 .. 10.05 10.05 10.00 10.00 FIXED ORIFICE FIXED ORIFlCE ' ED ORIFICE FIXED ORIFICE FIXED ORIFICE FIXED ORIFICE CHG TO 80 TXA042C4 17(A043C4 TXA01IC4 TXAOIIC4 17L4080C4 EXPANSION TYPE CHG TO 80 043 • 80 FACT INS 80 FACT INS 80 CHG TO 80 CHG TO 80 CHO TO 80 RATINGS (COOUNG) 0 STUN (TOTAL) 42000 .... 44500 43500 44000 45000 45000 INDOOR AIRFU7N (CFM) BTUH (SENSIBLE) 27100 :�� 29000 29000 29400 31300 31300 1200 1350 1250 v °: a:,: 1400 1350 1575 1575 SYSTEM POWER : t'' y % s.:; 4.57 4.87 488 4\11;.P. x 4,73 473 4.89 4,89 :' s SEER (BTWWATT•F .) .. ;. 10.05 10.05 -117 ' 10.05 10.10 10.05 10.05 TXC071Ct- 1X000$E5 TXCO3IS3 TX0037C4 11(037E5 TXV•NB CHG TO 80 TXV-B 42000 ' . .. 44000 44000 43000 27100 29000 29000 28300 1200 1275 1275 1350 4.57 , ; ,' , ..:. 4.68 4.68 4.67 10.05 'i .. ; j .• - , 10.25 10.55 10.05 44500 N700 1360 4.73 • 10.25 Pub. Ma. 22. 1641.03.1296 (EN) :C'. .. :k,i�1' .:f, T -.•.roe .i E.. -o.t nvt ... Nlu�:t ;Ad' rk% EXPANSION TYPE TXV-NB FACT INS 80 FACT INS 80 CHG TO 80 RATINGS (COOUNG) CD BTUH (TOTAL) 44500 44500 43500 44000 BTUH (SENSIBLE) 29700 29000 29000 29400 INDOOR AIRFLOW (CFM) 1350 1250 1400 1350 SYSTEM POWER (KW) 4.73 4.86 4.73 4.73 SEER (BTUIWATT -HR.) 10.50 10.35 10.05 10.10 EXPANSION TYPE RATINGS (COOUNG) O BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) SEER (BTU/WATT-HR.) EXPANSION TYPE CHG TO 80 TXV-NB RATINGS (COOUNG) O BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) SEER (BTU/WATT -HR.) RATINGS (COOUNG) O . BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CPA) SYSTEM POWER (KW) SEER (BTU'W TTFR) EXPANSION TYPE - • RATINGS 4J" :, BTUH (OhU -a ; t BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER SEER (BTU/WATT-HR.) Pub. Na 22.164t O3.1iYS (EN) TXCO37S3 TXC042C4 TXC043C4 TXCO4$C4 TXCO54S3 TXC060C5 TXC065S3 TXV-NB TXV$ TXV-NB 45000 45000 46000 31800 31700 32500 1575 1575 1575 4.86 4.86 4.89 10.40 10.10 10.55 CONDENSING UNIT WITH AIR HANDLERS TWE036C14 TWE036P13 42500 43000 43500 27500 28100 28900 1350 1350 ,1400 4.72 4.75 4.58 10.00 10.05 10 TWEO4SPI3 TWE060A•8 EXPANSION TYPE TXV-NB TXV-B RATINGS (COOUNG) 0 BTUH (TOTA 45500 44500 BTUH (SENSIBLE) 33000 34100 INDOOR AIRFLOW (CFM) 1575 1575 SYSTEM POWER SEER (BTUIWAT FHR.j 10.50 10.30 TWNO36814 119103111114 EXPANSION TYPE CHG TO OD CHO TO 80 43500 29400 1350 4.81 10.05 CONDENSING '.UNIT 1DOOIORI113 TDDOIM1111s +TXCOMES +TXOODM TXV$ TXV44 44500 29600 1325 4.66 10.70 'Sae pages 20 and 21 brcombInadons will & iry Wm. General Data 43500 29000 1360 10. 44500 `. 29600 1325 4.68 10.66 47000 34100 • 1575 5.03 10.50 45000 30000 1400 4.64 10.90 13 TXH033A4 CHG TO 80 TTAO42C3 /4O0A TXC049C4 TXCO50C4 TXCO54E5 CHG TO 80 CHG TO 80 TXV-B 45000 .. 31300/ 1575 4.89 10.05 45000 45000 31300 31800 1575 1575 4.89 4.86 10.05 10.10 101041A4 1131054A4 TXH063P3 CHG TO 80 CHG TO 80 TXV-NB 40000 44500 47000 47000 25500 29500 33400 34100 1125 1400 1575 1575 4:44 4.78 4.97 4.95 :10.00 10.20 10.25 10.70 TWE037E13 / TWEO40E13 TWE042C14 TWE042P13 TWE048C14 -B TXV-NB f % TXV-NB FACT INS 80 TXV-N8 CHG TO 80 45000 43000 44000 45500 30200 28400 29400 31100 1225 1350 1400 1575 4.50 4.73 4.76 4.97 1125 10.10 10.35 10.15 TWE063P13 TXV-NB 47000 33700 1575 5.14 10.25 TWE065E13 TXV-NB 44500 30400 1400 4.61 10.85 47500 27600 1450 4.68 11.40 45000 30300 1400 464 10.85 TWG042A14 FACT INS 80 42000 1400 4.67 10.00 WITH FURNACES & COILS TDOLOMMVB TD0100R9V5 T00100RSV5 1000I111/V5 +TX0107E5 +TXCOQ7S3 +TXCO54E5 MOMS URI TXVNB TWO • TXV4B 440' 30400 1400 4.81 10.80 100100RIV5 +1X110I3PS ' • TXII41B 47000 s: •=- 1400 4.70 11.00 • OUTDOOR UNIT OO POWER CONNS. - V/PH /HZ MIN. BRCH. CIR. AMPACITY O BR. CIR. 1 MAX. (AMPS) PROT. RTG.1 RECMD. (AMPS) NOISE RATING (DECIBELS) O COMPRESSOR NO. USED • NO. SPEEDS VOLTS/PH HZ R.L AMPS - LR. AMPS BRCH. CIR. SELEC. CUR. AMPS OUTDOOR FAN - TYPE DIA. (IN.) • NO. USED TYPE DRIVE - NO. SPEEDS CFM G 0.0 IN. W.G. 0 NO. MOTORS • HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS OUTDOOR COIL - TYPE ROWS - F.P.I. FACE AREA (S0. FT.) TUBE SIZE (IN.) REFRIGERANT LBS. - R -22 (0.0. UNIT) O FACTORY SUPPLIED LINE SIZE - IN. OA GAS O LINE SIZE - IN. 0.Q 110. FCCV - RESTRICTOR ORIFICE SIZE DIMENSIONS OUTDOOR UNIT - CRATED (IN.) UNCRATED WEIGHT SHIPPING (LBS.) NET (LBS.) EXPANSION TYPE RATINGS (COOLING) 0 STUN (TOTAL) STUN (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) SEER (BTUNIATTHR.) EXPANSION TYPE RATINGS (COOLING) O MN (TOTAL) STUN (SENSIBLE) INDOOR AIRFLOW (CFA) SYSTEM POWER (KW) SEER (BTUIWATT.IW.) . -' T10108444 TDIOS3P3 FACT INS 83 , "•TX1i EXPANSION TYPE • RATINGS (COOLING) 0 STUN (TOTAL) STUN (SENSIBLE) INDOOR AIRFLOW (CFA) SYSTEM POWER (KW) SEER (RUN/ATTAR) 'Sao pap 21 br ccmbis8ois WI Anir Dwicw. tit 1� z 1+ Pub: N0. 22. 1641-03.1286 (ice, z j.4t ;. CC8848MACC CC11048MACC FIXED ORIFICE FIXED ORIFICE 45000 29000 1250 497 10.00 TTA0411C300A 200230/3/60 22 3590 35/30 82 CLIMATUFP 1 -1 20012309/60 16 -101 16 PROPELLER 18.1 DIRECT - 1 2215 1 - 1/4 1075 200230/1/60 1.7 SPINE RN"' 1 - 24 16.84 3B 7 -LBS.. 2 -01 YES 1 1B 3/8 General Data :. TXCOI8,S3 TXN041A4 • • ' TXV NB GIG TO 83 ituo '1800 0.083 H X W X D 33-1/4 X 26-1/2 X 30 SEE OUTLINE DWG. 211 200 CONDENSING UNIT 46500 31500 1800 5.17 10.00 47500 31E00 1575 10.00 - TTA048C400A 460/3/60 10 15 15 82 CLIMATUFP 1.1 460/3/60 7.51 7 PROPELLER 18 -1 DIRECT - 1 2215 1.1/4 1075 460/1/60 0.8 SPINE FIN"' 1 - 24 16.84 318 7 -LBS., 2 -0Z YES 1 1/8 3/8 0.083 H X W X D 33.1/4 X 26.12 30 SEE OUTLINE 21 C 060ASACC CUBBAIMACC CUBC48A4ACC TXVB FIXED ORIFICE FIXED ORIFICE 48000 34.500 1800 5.30 10.00 71PAME TTA048C3 /400A 0 CERTIFIED IN ACCORDANCE WITH A.R.I. ANDARD 210/240. 0 RATED IN ACCORDANCE WITH A.A.I. ANDARD 270. SPLIT SYSTEM O CALCULATE ' ACCORDANCE WITH NAIL ELECTRIC CODE SUITABLE 7313 USE WITH HACK CIRCUIT BREAKERS OR FUSES. O STANDA • • AIR - DRY COIL - OUTDOOR O THIS LUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT AMEPLATE AND SERVICE INSTRUCTION. O LINEAR LENGTH B0 FT; MAX LIFT - SUCTION 60 FT; MAX. - LIQUID 60 Ft MAX. LENGTH OF PRECHARGED TUBING 50 . FOR GREATER LENGTH REFER TO REFRIGERANT PIPING MANUAL PUB. NO. 32-3009. ITH COOLING COILS 45000 29000 1250 4.97 10.00 CUBD60ASACC TXA048C4 TXV-8 FACT INS 83 46500 48000 46000 31500 34500 30200 1600 1800 1350 5.17 5.30 503 10.00 10.00 10.00 TXC048C4 TXC041C4 TXC064ES TXCO64S3 TXCOSOC6 FACT' INS 83 FACT INS 83 48000 . 32500 .1350 ?:: {t, ?r .`n'' 1600 5-03 4. 11,.. 521 Y r 1000. ^.. =;1;r4•- 10.20 TXV.8 TXY-NB TXV-0 47000 47500 48000 32500 33500 • 33800 1E00 1700 :..1700 5.18 525 527 10.00 10.15 10.00 TWG046A14 EXPANSION TYPE FACT INS 83 RATINGS (COOLING) 0 BTUH (TOTAL) 47500 BTUH (SENSIBLE) 31900 INDOOR AIRFLOW (CFM) 1600 SYSTEM POWER (KW). 5.31 SEER (BTU/WATT -HR.) 10.00 General Data CONDENSING UNIT WITH AIR HANDLERS CONDENSING UNIT WITH FUR ACES & COILS TUD100R9V5H 111D140R9V5 TUY100" 4A TUY100R9V4A TUYI20R9V5 +TXHO63P3 +TXC066S3 +TX •' • +TXC064.S3 +TXC065S3 TXV•NB TXV4IB TXV-NB TXV-NB 46000 46000 48000 30600 30600 32200 1350 1350 1400 4.92 4.92 4.97 10.50 10.50 10.75 TTA048C3 /400A TWE042C14 TWE042P13 TWEO48C14 -B `'TWE041P13 TWE060P13 z, - • 3 TWE065E13 EXPANSION TYPE CM TO 83 TXV-NB FACT INS 83 TXV-NB TXV-NB B TXV-NB RATINGS (COOUNG) 0 BTUH (TOTAL) 45000 47000 48000 47000 49000 50000 49500 BTUH (SENSIBLE) 29200 31700 32400 33400 36500 37300 33900 INDOOR AIRFLOW (CFM) 1350 1575 1600 1600 1800 1800 1375 SYSTEM POWER (KW) 5.03 5.25 5.33 5.08 5.33 5.62 4.97 SEER (BTU/WATT -HR.) 10.00 10.00 10.05 10.00 10.25 10.00 11.20 EXPANSION TYPE TDD100R9V5 1DD100R9V5 TDD100R9V5 TDCR20R9V5 TUDIOOR9V5 TUD100R9V5 TUD100R9V5 +TXCO54E5 +TXCO54S3 •+TXH063P3 +7XH063P3 +TXCO54E5 +TXCO54S3 +TXC065S3 EXPANSION TYPE RATINGS ( COOUNG) 0 BTUH (TOTAL) 47000 47000 50000 49500 47000 47000 48000 BTUH ( SENSIBLE) 32800 32800 35700 35400 33100 33100 32300 INDOOR AIRFLOW (CFM) 1625 1625 1600 1600 1675 1675 1400 SYSTEM POWER (KW) 5.05 5.05 5.21 5.03 5.16 5.16 4.92 SEER (BTU/WATT•HR.) 10.00 10.10 10.75 10.70 10.00 10.00 10.65 TXV.B TXV-NB TXV-NB TXV-NB TXV-B TXV-NB TXV-NB • OUTDOOR UNIT 00 POWER CORNS. - WPHHZ MIN. BRCH. CIR. AMPACIVY 0 BR. CIR. 1 MAX. (AMPS) PROT. RTG.J RECMD. (AMPS) NOISE RATING (DECIBELS) 0 COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L AMPS - LR. AMPS BRCH. CIR. SELEC. CUR. AMPS OUTDOOR FAN - TYPE DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM 0 0.0 IN. W.G. 0 NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS OUTDOOR COIL - TYPE ROWS - F.P.I. FACE AREA (S0. Ft) TUBE SIZE (IN.) REFRIGERANT (.8S. - R -22 (0.D. UNIT) 0 FACTORY SUPPLIED UNE SIZE • IN. O.D. GAS 0 LINE SIZE - IN. O.D. LID. 0 FCCV - RESTRICTOR ORIFICE SIZE DIMENSIONS OUTDOOR UNIT - CRATED (IN.) UNCRATED WEIGHT SHIPPING (LBS.) NET (LBS.) EXPANSION TYPE RATINGS (COOLNIG) O BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CRA) SYSTEM POWER (KW) SEER (1111.1/WATT-HR.) ' EXPANSION TYPE RATINGS (TOTAL) Ai) 0 BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) r SYSTEM POWER i ,- SEER (BTUMTTIIR) EXPANSION TYPE RATINGS ( TO1 L) - 0 {t •+ IN (CFM) SYSTEM POWER (KW) :. SEER (BTWWATT4111.) TXA010C5 TXV$ 5e000 37000 1700 14 'See Page 21 br ccenbkolion8 Autry D, sic s. Pub. No. 22.1641-01.1200 (B9`'= 56000 36600 1675 5.63 10.40 7X 51000 40800 2000 406 1490 TTA060C300A 200/230/3/60 23 40 40 84 CLIMATUFP 1 -1 206001/60 19 - 139 15 PROPELLER 22 -1 DIRECT - 1 3031 1 -1/4 825 200/23011/60 1.9 SPINE APP 1 - 24 25.50 3/8 9 -LBS.. 2 -01 YES 1 1/8 are 0.092 H X W X D 41 -1/4 X 34-3/4 X 30-1/2 SEE OUTLINE DWG. 254 239 General Data 56000 39600 2000 404 10.50 33600.: • 1380 43100: ' ..417 :.1460; TTA060C400A 460/3/60 14 20 20 84 CLIMATUFP 1 -1 460/3/60 9 -71 10 PROPELLER 22 -1 DIRECT - 1 3031 1 -1/3 825 46011/60 1.0 SPINE FIN" 1 -24 25.50 3/8 9 -LBS., 2 -01 YES 1 1/8 3/8 0.092 H X W X D 41 -1/4 X 34-3/4 X 30-1/2 SEE OUTLINE DWG. 254 239 CONDENSING UNIT WIT COOLING COILS CC130e0A4ACC CCB060ASACC CU FACT INS 92 TXVB FIXED OR TXCOgC4 TXC041C4 01G TO 92 ' CHG TO 92 UMW' ' TXH064Ai :Thh4013P3 CHGTO92 59600 39500 1700 6.01 10.70 17 TXC060C4 Dili TO 92 55000 56000 36100 36100 1675 :..- ;.7`1675 5 . 7 9 10.30 0 CERTIFIED IN ACCORDANCE WITH A.R1. STANDARD 2101240. 20 RATED IN ACCORDANCE WITH A.RJ. STANDARD ' O. J SPUT SYSTEM O CALCULATED IN ACCORDANCE WITH NAIL ELECTRIC CODE. SUITABLE FOR USE Wf1H HACR CIRCUIT BREAKERS OR FUSES. 0 STANDARD AIR - DRY COIL • OUTDOOR O THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT NAMEPLATE AND SERVICE INSTRUCTION. O MAX. LINEAR LENGTH 80 FT; MAX. UFT - SUCTION 60 FT; MAX. LIFT - LIOUID 60 FT. MAX. LENGTH OF PRECHARGED TUBING 50 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING MANUAL' PUB. NO.32.3009. CUBD60A5ACC TXV4 3 58000 39600 2000 6.04 10.50 TXV41B • • 60600 • 2000 • , 11.06 TTA060C3 /400A TXA048C4 CHGTO92 53000 33600 1350 5.58 10.25 TXC064E5 TX00643 TXC010C5 nem TXV•NB TXV8 55500 56000 36800 36900 1700 1700 5.81 5.80 10.35 10.70 TXA049C4 TXA060C4 CHGTO92 CHGTO92 55000 56000 36100 36100 1675 1675 5.79 5.79 10.30 10.30 56000 37000 1700 .' • 10.40 re m 00 too. 1 W= ' J F-- W O' LL < N 3. Lu Z�. 0 I- `W - O; ll! Z N ' I- = ' • O I... Z .. EXPANSION TYPE RATINGS (COOLING) 0 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) SEER (BTU/WATT-HR.) EXPANSION TYPE RATINGS (COOLING) 0 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) SEER (BTUIWATT.HR.) 'See page 21 br combinations with Auxiary Devices. CONDENSING TWE048C14-B TWE048P13 CHG 70 92 TXV.NB 56000 36800 1800 6.02 10.35 57500 39500 2000 6.05 10.60 General Data 56500 38600 1800 5.74 10.40 CONDENSING UNIT TD0100R9V5 ♦TXC95463 UNIT WITH AIR HANDLERS TWE060P13 TWE063P13 TWE065E13 TXVNB TXV-NB TXV.NB 511500 40100 1800 5.94 10.60 59500 60000 41000 42400 1825 1900 6.23 6.06 10.65 11.05 WITH FURNACES & COALS TTA060C3 /400A ''Ai; Pub. flu. 22-16414:1-1296 (EN) OUTDOOR UNIT 00 POWER CONNS. — V/PWHZ MIN. BRCH. CIR. AMPACITY O BR. CIR. 1 MAX. (AMPS) PROT. RTG.1 RECMQ (AMPS) NOISE RATING (DECIBELS) 0 COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L AMPS - LR. AMPS BRCH. CIR. SELEC. CUR. AMPS OUTDOOR FAN — TYPE DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM 0 0.0 IN. W.G. O NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ EL AMPS OUTDOOR COIL — TYPE ROWS - F.P.I. FACE AREA (SO. Ft) TUBE SIZE (IN.) REFRIGERANT LBs. — R -22 (0.0. UNIT) 0 FACTORY SUPPLIED LINE SIZE - IN. 0Q GAS UNE SIZE - IN. 0.Q LIO. OO FCCV — RESTRICTOR ORIFICE SIZE DIMENSIONS OUTDOOR UNIT • CRATED (IN.) UNCRATED WEIGHT SHIPPING (LBS.) NET (LBS.) EXPANSION TYPE RATINGS (COOLING) 0 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER / SEER (BTWWATT•HL) TXH083P3 TXV•NB 70000 48300 2225 7.87 8.9019.70 TTA072C300A 200/230/3160 30 50/45 40 84 CLIMATUFP 1 -1 20023M/60 22 -124 22 PROPELLER 26 -1 DIRECT -1 5100 1 - 1/3 825 230/1/60 2.2 SPINE FIN"' 1 - 24 35.39 3/8 13 •LBS., 0-0Z- YES 1 1/8 3/8 0.095 H X W X D 45.12X41 X37 SEE OUTUNE DWG. 333 314 General Data TWEb80P13 TW900A48 f WANG TXIFNB TTA072C400A 460/3/60 14 20 20 84 CLIMATUFP 1 -1 460/3/60 10.6 -64 10.1 PROPELLER 26.1 DIRECT - 1 5100 1 -1/3 825 460/1/60 1.7 SPINE FIN"' 1 -24 35.39 3/8 13 -LBS., 0•01 YES 1 1/8 318 0.095 H X W X O 45.12 X 41 X' SEE OUTUNEWJG. 333 314 CONDENSING UNIT WITH COOLING O CERTIFIED IN ACCORDANCE WITH A.R}(STANDARD 2101240. 0 RATED IN ACCORDANCE WITH AA1. STANDARD 270. TTA072C3 /400A COILS CONDENSING UNIT WITH AIR HANDLERS / SPLIT SYSTEM 0 CALCULATED IN ACCORDANCE WITH NATL ELECTRIC CODE. SUITABLE FOR USE WITH HACR CIRCUIT BREAKERS OR FUSES. 0 STANDARD AIR - DRY COIL - OUTDOOR 0 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT AND SERVICE INSTRUCTION. 0 MAX. LINEAR LENGTH 80 FT: MAX. LIFT - SUCTION 60 FT; MAX. UFT - LIQUID 60 FT. MAX. LENGTH OF PRECHARGED TUBING 50 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING MANUAL PUB. NO. 32-3009. FAN OUTDOOR INDOOR DELAY TXV COOUNG MODEL MODEL KIT KIT CFM SEER CAPACITY TTA030C3/400A CCBA30A4ACC Y N 950 10.00 28200 TTA030C3/400A CCBA36MACC Y N 1090 10.10 29200 TTA030C3/400A CCBB30A4ACC Y N 1000 10.20 29400 TTA030C3/400A CCBB36A4ACC Y N 1100 10.15 29400 TTA030C3/400A CUBA30A4ACC Y N 950 10.00 28200 TTA030C3400A CUBA36A4ACC Y N 1090 10.10 29200 TTA030C3/400A CUBB30A4ACC Y N 1000 10.20 29400 TTA030C3/400A CUBB36A4ACC Y N 1100 10.15 29400 TTA030C3/400A TWE024C14 - Y 900 10.00 27200 TTA030C3/400A TXA024C4 Y N 900 10.00 28200 TTA030C3/400A TXA025C4 Y N 900 10.10 28600 TTA030C3/400A TXA030C4 Y N 1000 10.15 29400 TTA030C3/400A TXA031C4 Y N 1000 10.30 30600 TTA030C3/400A TXA035C4 Y N 1100 10.15 29600 TTA030C3/400A TXA035C4 N Y 1095 10.15 29400 TTA030C3/400A TXA036C4 Y N 1125 10.20 30800 TTA030C3/400A TXA037C4 Y N 1125 10.20 30800 TTA030C3/400A TXA042C4 Y N 1125 10.25 31000 TTA030C3/400A TXA043C4 Y N 1125 10.25 31000 TTA030C3/400A TXCO24C4 Y N 900 10.00 28200 TTA030C3/400A TXCO25C4 Y N 900 10.10 28600 TTA030C3/400A TXCO30C4 Y N 1000 10.15 29400 TTA030C3/400A TXCO31C4 Y N 1000 10.30 30600 TTA030C3/400A TXCO31E5 Y N 1000 10.50 30400 TTA030C3400A TXCO35C4 Y N 1100 10.15 2960 TTA030C3/400A TXCO35C4 N Y 1095 10.15 294 TTA030C3/400A TXCO36C4 Y N 1125 10.20 30''0 TTA030C3/400A TXCO38E5 Y N 1125 10.50 600 TTA030C3/400A TXCO37C4 Y N 1125 10.20 •0800 TTA030C3/400A TXCO37E5 Y N 1125 10.50 31800 TTA030C3/400A TXC042C4 Y N 1125 10.2 31000 TTA030C3/400A TXC043C4 Y N 1125 10 31000 TTA030C3/400A TXH025A4 Y N 900 .05 28000 TTA030C3/400A TXNO25A4 Y Y 900 0.05 28000 TTA030C31400A 1X}1033114 Y N 1000 10.25 29800 TTA030C3/400A TXH033A4 N Y 1000 10.30 29400 1TA031C31400A CCBA36MACC Y N 1100 10.30 34200 TTA036C3/400A CC8838MACC Y N 1100 10.35 34600 T1A036C31400A CC8842A4ACC Y N 1200 10.40 34800 TTA036C3/400A CUBA36A4ACC Y N 1100 10.30 34200 TTA038C3/400A CUB836MACC Y N 1100 10.35 34600 TTA036C3/400A CU8842MACC Y N 1200 10.50 34800 TTA035C31400A TWHO36814 - Y 1200 10.50 35500 TTA036C3/400A TXA030C4 Y N 1100 10.35 34200 TTA036C3/400A TXA031C4 Y N 1100 10.35 34800 Ratings with Auxiliary Devices COMBINATIONS WITH FAN DELAY RELAY KIT AND /OR TXV KIT 'When models are matched with an indoor air handler or coil that has a llow control check valve or expansion valve Bow control, the addition of an indoor fan delay relay and/or TXV kit may increase the system SEER. See charts below for ratings. OUTDOOR INDOOR MODEL MODEL TTA036C3/400A TXA035C4 TTA036C3/400A TXA035C4 TTA036C3/400A TXA036C4 TTA036C3/400A TXA037C4 TTA036C3/400A TXA042C4 TTA036C3/400A TXA043 TTA036C3/400A TXAOJ19C4 TTA036C3/400A TX%049C4 TTA036C3/400A , 7 A050C4 TTA036C3/400A/ TXAOSOC4 TTA036C3/400A TXCO30C4 TTA036C3/460A TTA036C31400A TTA03§C3/400A TTA C3/400A TT D36C3/400A WA036C3/400A A036C3/400A TTA036C3/400A TTA036C3/400A TTA036C3/400A TTA036C3/400A TTA036C3/400A TTA036C3/400A TTA036C3/400A TTA036C3/400A TTA036C3/400A TTA036C3/400A TTA036C3/400A TTA036C3/400A TTA042C3/400A TTA042C3I400A TTA042C3/400A TTA042C3/400A TTA042C3/400A TTA042C3/400A TTA042C3/400A TTA042C3/400A TTA042C3/400A TTA042C3/400A TTA042C3/400A TTA042C3/400A TTA042C3/400A TTA042C3/400A TTA042C3/400A START KIT REQUIRED 20 FAN DELAY TXV COOLING KIT KIT CFM SEER CAPACITY Y N 1100 10.30 34200 N Y 1100 10.30 33800 N 1200 10.50 36400 N 1200 10.50 35800 Y N 1250 10.50 36400 Y N 1350 10.50 36800 Y N 1350 10.50 37400 Y N 1350 10.50 37400 Y N 1350 10.50 37400 N Y 1350 10.60 36600 Y N 1100 10.35 34200 TXCO31C4 Y N 1100 10.35 34600 TXCO31E5 Y N 1100 10.65 35600 TXCO35C4 Y N 1100 10.30 34200 TXCO35C4 N Y 1100 10.30 33800 TXCO36C4 Y N 1200 10.50 36400 TXCO36E5 Y N 1200 10.75 36600 TXCO37C4 Y N 1200 10.50 35800 TXCO37E5 Y N 1200 10.75 36600 TXC042C4 Y N 1250 10.50 36400 TXC043C4 Y N 1350 10.50 36800 TXC048C4 Y N 1350 10.50 37400 TXC049C4 Y N 1350 10.50 37400 TXCO50C4 Y N 1350 10.50 37400 TXCO50C4 N Y 1350 10.60 36600 TXCO54E5 Y N 1350 10.60 37000 TXH033A4 Y N 1125 10.35 34600 TXH033A4 N Y 1125 10.35 34200 TXH041A4 Y N 1350 10.55 37400 TXH041A4 N Y 1350 10.60 38800 CC8842A4ACC Y N 1200 10.30 42000 CC8848A4ACC Y N 1250 10.35 42500 CC8C48A4ACC Y N 1575 10.25 44000 CUB842MACC Y N 1200 10.30 42000 CU8848A4ACC Y N 1250 10.35 42500 CUBC48A4ACC Y N 1575 10.25 44000 TWE048C14 -13 - Y 1575 10.20 45000 TXA035C4 ` Y N 1100 10.10 40000 TXA030C4 Y N 1200 10.30 42000 TXAO3TC4 Y N 1350 10.30 43000 TXA042C4 Y N 1250 10.50 44500 TXA043C4 Y N 1400 10.30 43500 TXA048C4 Y N 1350 10.40 44000 TXA049C4 Y N 1575 10.35 45000 TXA050C4 Y N 1575 10.35 45000 • Pub. Na 2211541-034296 (EN) 1 z �W, re 00 0) W W W O LL ': CO ° . 1- W Z W Off. U 0, O N 0 H W - O: .Z W F - OIL Z Ratings with Auxiliary Devices mows COMBINATIONS WITH FAN DELAY RELAY KIT AND /OR TXV KIT 'When models are matched with an indoor air handler or coil that has a flow control check valve or expansion valve flow control, the addition of an indoor fan delay relay and/or TXV kit may increase the system SEER. See charts below for ratings. FAN FAN OUTDOOR INDOOR DELAY TXV COOUNG OUTDOOR INDOOR DELAY TXV COOUNG MODEL MODEL KIT KJT CFM SEER CAPACITY MODEL MODEL KIT KIT CFM SEER CAPACITY TTA042C3/400A TXA060C5 Y N 1575 10.40 45000 TTA048C3/400A 11A050C4 N Y 1600 10.15 47000 TTA042C3/400A TXCO35C4 Y N 1100 10.10 40000 TTA048C3/400A TXA060C5 Y N 1700 10.20 48000 TTA042C3/400A TXCO36C4 Y N 1200 10.30 42000 TTA048C3/400A TXC042C4 Y N 1250 10.15 45000 TTA042C3/400A TXCO36E5 Y N 1275 10.55 44000 TTA048C3/400A TXC043C4 Y N 1575 10.10 46500 TTA042C3/400A TXCO37C4 Y N 1350 10.30 43000 TTA048C3/400A TXC048C4 Y N 1350 10.20 46000 TTA042C3/400A TXCO37E5 Y N 1350 10.55 44500 TTA048C3/400A TXC049C4 Y N 1600 10.30 47500 TTA042C3/400A TXCO42C4 Y N 1250 10.50 44500 TTA048C3/400A TXCO50C4 Y N 1600 10.15 47500 TTA042C3/400A TXC043C4 Y N 1400 10.30 43500 TTA048C3/400A TXCO50C4 N Y 1600 10.15 47000 TTA042C3/400A TXC048C4 Y N 1350 10.40 44000 TTA048C3/400A TXCO54E5 Y N 1600 10.20 47000 TTA042C3/400A TXC049C4 Y N 1575 10.35 45000 TTA048C3/400A TXC060C5 Y N 1700 10.20 48000 T7A042C31400A TXCO50C4 Y N 1575 10.35 45000 TTA048C3/400A TXH041A4 Y N 1575 10.25 47500 TTA042C3/400A TXCO54E5 Y N 1575 10.40 45000 TTA048C3/400A TXH041A4 N Y 1575 10.20 47000 TTA042C3/400A TXC060C5 Y N 1575 10.40 45000 TTA048C3/400A TXH054A4 Y N 1600 10.50 49500 TTA042C3/400A TXH033A4 Y N 1125 10.10 40000 TTA048C3/400A TXH054A4 N Y 1600 10.50 49000 TTA042C3/400A TXH033A4 N Y 1125 10.05 39000 TTA060C3/400A CCBC60A4ACC Y N 1675 10.65 56000 TTA042C3/400A TXH041A4 Y N 1400 10.50 44500 TTA060C3/400A CCBD60A5ACC - N 2000 10.70 58000 TTA042C3/400A TXH041A4 N Y 1400 10.50 44000 TTA060C3/400A CUBC60A4ACC Y N 1675 10.65 56000 TTA042C3/400A TXH054A4 Y ' N 1575 10.55 47000 TTA060C3/400A CU6060A5ACC Y N 1900 10.75 57500 TTA042C3/400A TXH054A4 N Y 1575 10.60 46500 TTA060C3/400A TXA048C4 Y N 1350 10.55 53000 TTA040C31400A CCB848A4ACC Y N 1250 10.15 45000 TTA060C3/400A TXA049C4 Y N 1675 10.60 55000 TTA048C3/400A CCBC48MACC Y N 1600 10.10 46500 TTA060C3/400A TXAOSOC4 Y N 1675 10.60 55000 TTA048C3/400A CCBC60MACC Y N 1675 10.05 46500 TTA060C3/400A TXA050C4 N Y 1675 10.60 55000 TTA048C3/400A CCBD6OASACC - N 1800 10.15 48000 TTA060C3/400A TXA060C5 Y N 1700 10.70 56000 TTA048C3/400A CUBB48A4ACC Y N 1250 10.15 45000 TTA060C3/400A TXC048C4 Y N 1350 10.55 53000 TTA048C31400A CUBC48A4ACC Y N 1600 10.10 46500 TTA060C3/400A TXC049C4 Y N 1675 10.60 55000 TTA048C31400A CUBC60A4ACC Y N 1675 10.05 46500 TTA060C3/400A TXCO50C4 Y N 1875 10.60 55000 TTA048C3/400A CU80130A5ACC Y N 1800 10.15 48000 TTA060C3/400A TX0050C4 N Y 1675 10.60 55000 TTA048C3/400A 11A042C4 Y N 1250 10.15 45000 TTA060C3/400A TXCO54E5 Y N 1700 10.65 55500 TTA048C3/400A TXA043C4 Y N 1575 10.10 46500 TTA060C3/400A TXC060C5 Y N 1700 10.70 56000 TTA048C3/400A TXA048C4 Y N 1350 10.20 46000 TTA060C3/400A TXH054A4 Y N 1700 11.00 59500 TTA048C3/400A TXA049C4 Y N 1600 10.30 47500 TTA060C3/400A TXH054A4 N Y 1700 11.05 58500 TTA048C3/400A TXA050C4 Y N 1600 10.15 47500 C o. ■ 4n 0 ' W es. g J: • N • Z k 1- 0. •Z I W W' en: i 1-- ;. .'W W; Z' • •U cD • ) .Z • Flan D.4%212147099 P05 N0. 22.1641.03.1296 (EN) SCHEMATIC DIAGRAMS TTA030,036,042,048C300A (SEE LEGEND) TTA060,072C300A MRS: EL ft goo MA 1 I L i 1 1 1 1 ttw —yo- 2111.0 1 -' 1 Q 4.16 r I wnt '1) rff0■111111•■•■■11.-J r ai•. wr11y( r. twl. 91R. 1 i ■■.Lt ... wallet COM M . +1 r. • w 1 0111111T.MM• UnitaWI 14t•M 1. IMllta t*N / S • Lae R ; 1. ItMItI6 re llama W % 7..331 NItM11t ... a MlI silt. • WS Room COMM MR11t11111W• ••• 1141■ .:. gMCwMCI MP NO. ease f4 mw Ups, .- rell[n a► we Man �1�( + CND, COW •AtIre 1101•1_ t • a1r�110�11a �t1- asr.a11 III :at 11+44 11 MI [•11•11 Electrical Data .1 .• ILK At•lwi loull �I TO AK. 10.11 Nilsen .i(R.r/ K.ttl Mt • u•.1N1 H.nc n. \ --/ 1 �M 4. r�0 c .■ 079 - RK • rrMF.b� • 1 1 1 1 nuwo- O--_ - 1 CI [■:AZ 1 1 v 1 4 - 1 1 r- au.* *maw q�o- -■ — w — ■ .11(11 {■ or Me rut wow men, MOP WWI Wile al Nil wSionreasJ lmOMN OMAN ' 1' Os W .J 1 4111.1114' ■+& •M ILL , !MIME YR1.•M••nt10191b tilltONICII Vmu.tomeMUOWN. NS aim ant anyme Aura& tra1111 oft t IMMO% taw, lismarets • 11•110 A wwt alttl1 , • at71t1w� 'r Irma n r t. . 4444 tht M•I SCHEMATIC DIAGRAMS (SEE LEGEND) TTA030,036,042,048C40OA TTA060,072C400A f. MIS u•w. .Tauat ..40(411 saws, scat • Itgal w.KfKe \ -- II:..1. faN aafa- � ur �atl•. oif a� I,U■P Nit at -o ,TI Electrical Data WI` .�71f sL M --, 1 ( ; 1 1 IIw sal euo. —o I t C1 a �atf• . .. rw . f�l.a{ I t y I .1 1 pta•.lsm• • -10-- �• -� in T� I t ` to. -� i TI.aaa ea magi •1 I • I.. �1 A IvIsT - -a SIN a. wha .IIIl a, 1a _. I& • too sII Y1N.T .11 La foal ww Nn at M- ■■i../W —.. * III", '• r 1111.4 mit WO NCO OW MM SIt[ wlIIsM At SIMS 1. • Mart I T ° R I sIIs iIfa 4,4 3. UaI .T•a Q. LI rILO saw SWUM • *AS lay • Sewn u * r a 11 ssrs IaT MOM t. T SS CUM. O w' N l WI wan mum L » I CT lYllr Nat. gauss Tot! Ii IL•t . altaNtr Mg r el me PINS agar et unraNCTS Wes USK g s g w r i a m g x , T g SMC ICT Era It IIIIa a SI MI • gas WS CURD CMSir{ • rT sort RWgla* At "PI ciotn tw t, a tr, v*a MU ` I D may cOa naaa i, 114 IMSRiiT • a•1llt N 0 111010MMNTIt[ it SW II5 r • • t tell "Waft {tl tJ rnsww sat U w slums • ' / sraOrww 7ls•wlrwMU I. n akWRCI mist. swum irsIU rUi : Flom Owg. 210148055 PO4 • IVaua INK•Il1 �. -. Iyw1.• 1 Ylq' al �4.�at ��1 / —w• a• ttn i. I I iifa ♦_. f.aaa{ j 4 I �aatfl 1 - . -� - V a. 1; 1 Electrical Data LEGEND — C OLOR OF WIRE BK/BL BLACK WIRE wlrH BLUE MARKER 4 —COLOR OF MARKER . BK BLACK OR GRANGE fL YELLOW BL BLUE RD RED OR GREEN BR BROWN WH WHITE PR PURPLE SYMBOLS L I V. CAC TORY WIRING L NE v, L INC V. r IEL 0 WIRING L v; } -z— FIELD INSTALLED FACTORY WIRING 'L GROUND JUNCTION Q «IRE NUT OR CONNECTOR ▪ COIL �f- CAPACITOR -� - REL AY CONTACT 91.0.1 -y - RELAY CONTACT [N.C.) INTERNAL OVERLOAD PROTEC TOR PRESSURE ACTUATEOSWITCH - sAtJ` - RESISTOR OR HEATING ELEMEN O"'"''O Loony; WINDING 0 TERMINAL TERMINAL BOARD f1. TRANSfORMEp TEMIERATURE ACTUATEDSWITCH • Cr FAN CAPACITOR CN NUE COIIECTOI • . CPR COItPTESSOP • LP L PRESSURE CUT•OVT hCTOR' l • CO4PRESSOR WTOi CONGCTOI • DDT . ago= 1ERASTAT . •':I ',.. ; Ta WDERNWTAT RELAY ISOURGE LIK • '1. ELECTRICAL AND REFRIGERANT COMPONENTS CLEARANCES PER PREVAILING CODES. 28.6 11-1/81 OIA. K.O. WITH 22.2 17/81 DIA. HOLE ELECTRIC POWER SUPPLY 22.2 17/81 WA. HOLE LOW VOLTAGE SERVICE PANEL —10- No: 22434143.1220 (et ib +^Acri k ` ,' i. • . S i 121 s 010(244$) %3320114) ..2 s. 2 • 2 A11904419 RZ (32 -314) 10.72 004/3) 1137 (443/4) 713 (26114) 711 (2814) 711 (21414) 625(24.1410) % 730 (204) 10043µI D:! � El: , 17Ax 710 (26114) —GAS LINE SERVICE VALVE. "D "0.0. FEMALE BRAZED CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP. FITTING. LIQUID LINE SERVICE ' VALVE, "E "0.0. FEMALE BRAZED CONNECTION WITH I /4^ SAE FLARE PRESSURE. TAP FITTING. FIG. 1 .. :t i:aut4 174 ?.K. 60 12 3/81 Dimensions TTA030 -072C OUTLINE DRAWING C 40 MINE" NOTE: ALL DIMENSIONS ARE IN MM (INCHES). rt TOP DISCHARGE AREA E -+CUED OE uNRESTRICTEO EAST F'/E 151 - EET AOCVE U't .v =- +CL•LD EE 0L ACEC SO ROC= COES NOT PCUP zE: L J'. :!T AND SHCULC. AT EAST 3C5 12'1 FROM WALL AN: AL_ SURRCUNDISG SHRUBBERY ON "WC S :CES. .17=•_R TWO SIDES uNRESTR :CTGG. • SALLVWEE RE TAP ♦ 4i 'a a gERVICE 1 •Py � ,:.., � ..57a" -; ALEVALVE, • FLARE PRESSUJETAP FITTING. FREE Dwa 21D14701 Rs f '••!: ••• • ,*;", % < • 3 NP'c's ) 14, 7 • A , t • ,,. Notes • "Ne 4.3; , Vrtr 'IT 11 44,111,LIK. ,3 : • i• 4. MANE" Pub. N 224641-034298 (DI) ; . : , ^!;4"A..NT tk:1,5.1.47,A44V.14;;.'10 • 11:k•:+.(.::::2ttl'.41'0:`!4:.''["..„'...1.,.;',43,'..' " • • • • .1.. • • .. . • . • - A; • -• . • • , -NOTICE. IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN_ THIS NOTICE.IT IS DUE TO THE QUALITY OF THE DOCUMENT REGISTERED AS PROVIDED BY LAW AS, CONST • CONT GENERAL #.. EXP. DATE REGIST. . EFFEC ��TIVERD TE005BJ / /2000 EFFECTIVE HERMANSON COMPANY LLP '1221 2ND'AVEN KENT wk= 98032 -294 Signature lssucd by DEPARTMENT OR LAI30R.AND INDUSTRIES •; j .. ilk • ' �i f NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. File: 35mm Drawing# I. EXIST STAIRWAY IVAV -TBD5) BD 16x14 14x14 EXIST. TEL. /DATA 10" =NTRY EXIST LOBBY -1x12 400 -- kosassatitsl EXIST WOMEN RESTROOM EXIST JAN. A DUCT ST A. U -4 EXIST k ' RESTROOM ITTI IN 12x12 400 r (AC -TBD1 I I CU -TBD11 O I I : z O I N j I- _I W illausoft PROJ NO: 4569waTC PROJ MGR: ALLEN OLSEN T.. UNIT ELEVATION S ALE: 1/8" = 1' -0" 1 1 r1 0 INCH CHINA f N ireELEIC TRICAL PLIWIBING GAfA PIPvNG CITY OF TUKWILA FOURTH FLQOR HVAC PLAN - NEW SCALE: 1/8" = V-0" -0" PFAnSIONS, A.s2D Y'.�{'ti�0 Lli't.... ��..�a�i.ly:. ��.t..: i l te tiYti� FLAN FiEViEW FEES. . I I i 1 l ' I I J I V '1 ?U i rli 0 HERMANSON CORPORATION 1221 2ND AVENUE NORTH KENT, WASHINGTON 98032 Phone: (206) 575 -9700 Fox: (206) 575 -9800 IIIIf IOW CAI leolf_A a PROJ MGR: WAYNE CORNELL PROJ NO: 4569waTC BUILDING: TUKWILA REVISION: CD - 1/29/01 s v C 2J. q 4_ -- s s C z ;�r,.4,L•f a }x: H .u.:l I. lib O . hIIIhIH 111111 11 1 11 1 11111111111 . 11.1111111i111i1111.111111. li 111, 1 . RECEIVED CITY OF TUKWILA iIII'. T:I III'`I I 5 1 Q.0 m CONSTRUCTION NOTES: E JAN 219 SEA EV E. 3� � � IT PERM% INSTALL NEW MEDIUM PRESSURE TRUNK AS SHOWN. 2. INSTALL (4) TITUS FAN POWERED VAV BOXES SUPPLIED BY BUILDING OWNER. INSTALL (3) VAV BOXES ON EXTERIOR ZONES SUPPLYING 12x12 DIFFUSERS AT 400 CFM EACH. INSTALL (1) VAV BOX . OVER KITCHEN SUPPLYING CONF RM, KITCHEN, STORAGE, AND HALLWAY. 3. INSTALL 8" SQUEEZE BOX PROVIDING 1050 CFM BACKUP TO NEW 3 TON TRANE DX SPLIT SYSTEM. 4. IN THE EVENT OF THE 3 TON TRANE SPLIT UNIT SHUTTING DOWN THE SQUEEZE BOX WILL PROVIDE BACK UP AIR TO SPACE. 5. INSTALL DUCTBOARD OR SOUNDLINED SHEETMETAL DIFFUSER SOUND CANS. 6. TEST AND BALANCE PER DRAWING NOTES. 7. PROVIDE CONNECTION TO DDC CONTROL SYSTEM, UPDATE COLOR GRAPHICS. 8. ALL JOINTS IN SUPPLY AND RETURN DUCTS SHALL BE SEALED WITH MASTIC. 9. ALL HVAC DUCTWORK TO BE INSULATED WITH A MINIMUM OF 1"x1.5# SOUNDLINER. WHERE SOUNDLINER IS NOT SHOWN ON 'PLANS, DUCT TO BE WRAPPED WITH 1 "x3/4# FOIL FACED DUCT WRAP. ALL I ` 101T - S fAcj CAMP 7 =wIT tiGIO11.-SIATtlESIE YfCOOE 1.A-: 5 nderstand that the Plan Check approvals are 1 :? to errors and omissions and approval of tuns does not authorize the violation of any dcpted code or ordinance. Receipt of con - actor's copy of approved plans acknowledged. By D SHEET NUMBER: M -D -01 PROJ NO: 4569waTC PROJ MGR: ALLEN OLSEN ROOF PLAN - NEW WORK SCALE: , /a = V—a 11 liTi ()INCH CHINA 5l. bl £1 J. IIIIILIIIIIIIIIIIIIIIIIII 1.1 IIIIIIIIII�I CU r NEAREST TBD11 PROJ MGR: WAYNE CORNELL HERMANSON CORPORATION PROJ NO: 4569waTC 0 1221 2ND AVENUE NORTH BUILDING: TUKWILA• KENT, 575 — 575-9700 Fox: 98032 (206) Phone: (206) 5 75 . REVISION: CD — 1/29/01 575 97 Fo: 6) 5• -9800 i 1 - I_ lii,:ITliLilllillli (hI I i i II tf [ £ Z IIIIII 1 11 IIIl af0, 1 .IlIIh1,1II1III1111111111Il11 IIHIl CONSTRUCTION NOTES: • 6 1. INSTALL CONDENSING UNIT ON ROOF AS SHOWN. 2. PROVIDE PIPING OVER TO ROOF MEMBRANE AND DOWN TO CEILING AIR HANDLER. 3. PROVIDE CONDENSATE DRAIN LINE TO NEAREST ROOF DRAIN. RECEIVED CITY OF TUKWILA -LA 2 q 2301 PERMIT CENTER FEB PiP (NO - 7 1 AS 110 ; LU SHEET NUMBER: M -D -02 SPLIT SYSTEM CONDENSING UNIT SCHEDULE C. CU —TBD1 MAKE TRANE MODEL TTA036C300A PROJ NO: 4569waTC PROJ MGR: ALLEN OLSEN UNIT SERVED DXFC — TBD1 ELECTRICAL VOLTS /PH 200/230/3/60 MCA 25 WGT. LBS. 181 t I I II INCH REMARKS DXFC # DXFC8 -1 D.X. FAN COIL SCHEDULE (SPLIT AREA SERVED IT CLOSET MAKE TRANE MODEL TWE036C14.0A,F MATCHING COND.UNIT CU — TBD1 COOLING ® MBH TOTAL 29.8 FAN PE CFM CFM .ENS. ESP j 20.8 1050 25 "H x 26-1/2"W x 30 "D • SYS RFORMANCE D .53 RPM .53 1075 HERMANSON CORPORATION 1221 2ND AVENUE NORTH KENT, WASHINGTON 98032 Phone: (206) 575 -9700 Fox: (206) 575-9800 TEM) TA MHP 1/ HTR. KW ELECTRICAL VOLTS /PH 200-230/1/60 MCA 3.3 FILTERS QTY 1 SIZE 20" x 20" x 1" WGT. LBS. 115 EER 10 REMARKS UNIT NO. VAV —TBD 1 VAV —TBD2 VAV —TBD3 VAV —TBD4 VAV —TBD5 MANUFACTURER MODEL NUMBER DTQS -03 DTQS -03 DTQS -03 DTQS -03 VCCE -08 INLET SIZE (IN.) 10 10 10 10 8 DISCH. PLENUM 16 "x13" 16 "x13" 16 "x13" 16 "x13" 16 "x14" COOL MAX 960 800 800 1200 1200 VAV BOX SCHEDULE CFM MIN 144 120 120 180 400 IN . 05 .05 . 05 _ .05 .05 CFM OUT 0.35 0.35 0.35 0.35 0.35 HEATER MAX KW D.T. VOLT /PH N/A 7 7 7 N/A N/A 35 35 35 N/A N/A 277/1 277/1 277/1 N/A FAN MOTOR HP VOLT /PH SPEED 1/4 1/4 1/4 1/4 N/A 277/1 277/1 277/1 277/1 N/A LO LO LO MED N/A NOTE NO. 2.1 FLA 2.1 FLA 2.1 FLA 2.1 FLA 2.1 FLA PROJ MGR: WAYNE CORNELL PROJ NO: 4569waTC BUILDING: TUKWILA REVISION: CD -- 1/29/01 5 I. , tit El. Zl . 'fi r 6 S k,. 1 \ ,. E Z 0 , IIIII 1111111111111111 1 111 1 11 1 . 11 1111111111I11lilid. X1111 .1111111 tIJ .fi 11 I .I. ....1.►1.1....... I..L..1.. i11LI_ LIILL�� . 1 1_► CIi YROFEI UKWILA 2 9 2001 PERMIT CENTER CM OF TIANitik APPROVED FEB 7 2001 As tiu s a) SHEET NUMpER: M-M-01