Loading...
HomeMy WebLinkAboutPermit M01-031 - SOUTHCENTER MALL - I MATERNITYMO1-031 aternity 18 .center Mall City ty of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M01 -031 Type: B -MECH Category: NRES Address: 1018 SOUTHCENTER MALL Location: Parcel #: 262304 -9004 - - Contractor License No: ARCHIIC043C1 TENANT I MATERNITY Phone: 1018 SOUTHCENTER MALL, TUKWILA, WA 98188 OWNER JOINT VENTURE ATTN: JAMES J GUDIN, 25425 CENTER RIDGE RD, CLEVELAND OH 44145 CONTACT ROB ROBINSON Phone: 253 - 848 -5948 10004 66 AV E, PUYALLUP, WA 98373 CONTRACTOR ARCHITECTURAL INT /CNST SRV INC Phone: 253 - 848 -5948 PO BOX 73397, PUYALLUP WA 98373 MECHANICAL PERMIT ******************************************** *, * * * * * * * * * * * * * * * * * * * ** * * * * * * ** Permit Description: INSTALL (2)_ DIFFUSERS AND DUCTWORK. _AMC Edition: 1997 Valuation: Total Permit Fee: : Name: Status: ISSUED Issued: 03/16/2001 Expires: 09/12/2001 200.00 46.50 * * * * * * * ** ************************ * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** )-Z Center Autho ized Signature Date I. ereby certify tha I hav read and examined this permit and know the ,,.same to be true and orrect. All provisions of law and ordinances governing this work ill be complied with, whether specified herein or not. The granting . of this permit does not presume to give authority to violate - or cancel_: the provisions of any other state or local laws regulating - constructio • the performance of work. I am authorized to sign for and - obtain thi- bui .1 g j it. Signature: = 4' Date: __ 3 /' d ,Two Title: ._This permit shall become null and void if the work is not commenced within 180 days from the . date issuance or if the work is suspended or - abandoned; for a. period of 180 days from the last inspection. ce Q ; w A w O Q . O O: . Z F wLa D O 0. —co; 0 .w w ; = U" w 0 - - 0 h'" z ..:.. ACTIVITY NUMBER: M01-031 DATE: 2-14-01 PROJECT NAME: I MATERNITY SITE ADDRESS: 1018 SOUTHCENTER MALL SUITE NO: XX Original Plan Submittal Response to Incomplete Letter # . ; Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Buil g !vision II 140C, Z--(5-0( Public Works I WRROUILDOC Complete Approved ri DETERMINATION OF COMPLETENESS: (Tues., Thurs.) APPROVALS OR CORRECTIONS: (ten days) Fire Prevention t A. 2-150/ Structural Approved I I Approved with Conditions REVIEWER'S INITIALS: CORRECTION DETERMINATION: REVIEWER'S INITIALS: PERMIT COORD COB' PLAN REVIEW/ROUT SLIP Planning Division Permit Coordinator DUE DATE: 2-15-2001 Incomplete ri Not Applicable TUES/THURS ROUTI G: Please Route Structural Review Required ri No further Review Required REVIEWER'S INITIALS: Approved with Conditions ri Not Approved (attach comments) Comments: DATE: DUE DATE 3-15-2001 Not Approved (attach comments) ri DATE: DUE DATE DATE: z ACTIVITY NUMBER: M01 -031 PROJECT. NAME: I MATERNITY SITE ADDRESS: 1018 SOUTHCENTER MALL SUITE NO: XX Original Plan Submittal Response to Correction . Letter # DATE: 2 -14 -01 Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comment X TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved WRROUIIDOC Mr, PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete Structural Review Required 14‘. REVIEWER'S INITIALS: Planning Division Permit Coordinator Not Applicable No further Review Required n DUE DATE: 2- 15-2001 5e1 DATE: DUE DATE 3 -15 -2001 Approved n Approved with Conditions Not Approved (attac comma ts) DATE: DUE DATE Approved with Conditions n Not Approved (attach comments) DATE: PERMIT NO.: A -031 MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 00002 Pre - construction ❑ . 00050 WSEC Residential ❑ 00060 WA Ventilation/Indoor AQC ❑ 00610 Chimney Installation/All Types O 00700 Framing 0 01080 Woodstove 01090 Smoke Detector Shut Off 01100 Rough -in Mechanical 01101 Mechanical Equipment/Controls ❑ 01102 Mechanical Pip/Duct Insul O 01105 Underground Mech Rough -in ❑ 01115 Motor Inspection 7 1400 Fire Final 01800 Final Mechanical ❑ 04015 Special -Smoke Control System CONDITIONS 0001 No changes to plans unless approved by Bldg Div ❑ 0014 Readily accessible access to roof mounted equipment 0016 Exposed insulation backing material 0019 All construction to be done in conformance w /approved plans ❑ 0002 Plumbing permits shall be obtained through King Co 0027 Validity of.Permit 0003 Electrical permits obtained through L & I 0036 Manufacturers installation instructions required on site ❑ "BTU maximum allowed per 1997 WA State Energy Code" ❑ 0041 Ventilation is required for all new rooms & spaces ❑ "Fuel burning appliances ❑ "Appliances, which gsnerate...." ❑ "Water heater shall be anchored...." voii Additional Conditions: .T TENANT NAME: FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (NUN) Furnace.Buner to 100,000 BTU (qry) Over 100,000 BTU (qty) Floor Furnace (qry) Suspended/Wall/Floor- mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP/1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfrn (qty) over 10,000 cfrn (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm/Ind (qry) Other Mechanical Equipment (qty) Other Mechanical Fee (enter SS) • Add'! Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'! Plan Review (hrs) Plan Reviewer: t1. Permit Tech: Date: Iy' Date: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M01 -031 DATE: 2- 14 -01 PROJECT NAME: I MATERNITY SITE ADDRESS: 1018 SOUTHCENTER MALL SUITE NO: X'X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works n C Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 2- 15-2001 Complete n Comments: TUES /THURS ROUTING: Please Route n Structural R v e Required REVIEWER'S INITIALS: CORRECTION DETERMINATION: NRROUII.IXJC WI Incomplete n Not Applicable No further Review Required DATE: �' tt7 /C/ Approved 1 Approved with Conditions n Not Approved (attach comments) APPROVALS OR CORRECTIONS: (ten days) DUE DATE 3-15-2001 REVIEWER'S INITIALS: DATE: DUE DATE Approved n Approved with Conditions [ Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Project Name/Tenant: 7 llr e 7y 0 Value of Mechanical Equipment: .2 -00 Site Address : � c�4 )E{�jate/Zip: Tax Parcel Number: /0/ so y, c �z tits l y<sJ r Property Owner:60 102: 42. M411 Phone: ( ) 04/Z3 7e26 t/6- Street Address: City State/Zip: _ b 3 s�:r) .66, 1-4- s-e4 - � GieWgce Fax #: ( ) 2-06 -AW- 8 ' 7 Phone : ) 1 '‘ V Contractor: Street Address: City State/Zip: Fax #: ( ) 9 - 3 - g - o Vs Ocic) t/ 6G A-c. V- Pa. p-f cut cl s '', Contact Person: 1 Phone: ( ) Street Address: * City State/Zip: /erica -/ 19 6 �A„r _p u yep e 1114 5 1 x'3'7 Fax #: ( ) LS7s --g - VS ;'BUILD GIO ' ' s ' A O IZED AGENT: Signatur : A, ` r /] �� Date: a 0 ,00/ Print name: • , (,�_ 60 "diti Phone( ) ^5`/t /b Fax #: ZS ) 5s9fs.,,.d cy Address: t * ! City/S to * : i W 9 . •3 Mechanical Permit Application MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specific): .4 `r - Lfit r) Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY. THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CITY OF '' I KWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. 11/2/99 meth pennh.doc R SIMF I USE ONI V Project Number. Permit Number. Mot- ck.51 Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: Q-Iy -o' Date application expires: g Applicatio taken by: (initials) ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 . H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut - off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal ESIDENTIAL: Two complete sets of attachments required with application submittal Heat loss calculations or Form H -6. Equipment specifications. 'll/2/99 ndscpnu.doc Submittal Requirements New Single Family Residence Change -out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code - please include any water heaters or vents being installed or replaced. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. CITY OF TUKWILA Address: 1018 SOUTHCENTER MALL Permit . No: , M01 -031 Suite: Tenant: I MATERNITY Status: ISSUED `Type: B-MECH Applied: 02/14/2001 Parce1., #: 262304 -9004 Issued: ` 03 /16/2001 ' k' k k' k• k**• k*' k**' k***' k' k***' k****• k• k- k***' kA: k**' k' k*' k* *'k**'k'k *'k•k'k'k * *'k'k"k'k *•k k'k'k k ** k k'k.k*•k*'k Permit Conditions:: `1..'Electrical.permits shall be obtained through the Washington State Division, of Labor and; Indut.r,ies and all electrical work will be inspected. "by•that,.agencv (248 -6630) 2 , No `changes will l.. be `made to the p 1 ans • un l`es, approved . by the Engineer a t -he .TukwilaYBuilding Division 3 All permi t's, inspection: records, and approved plans .shall be avai la the :10,b `site prior,` to the Mart: of any con { struct,i:on T.he.se" do c e,nt SKi er..,e..;to. be { m, nta i ned .acrd ava i 1- aii ] e u'ntri 1 f i al inspection approval i s" a r granted 4 Al -f- constructi onv:: to be - .'doi7e' i n conformance �wi th approve d m plans and'''requireen,ts dt The ,Uniform B`uildi.ng Code` (1997 �,Edai t ifon):" as $niende l,'t i.irii farm Mechanical Code t( i *97 Edition ) . apd Washington State Energy, Code 11997. Ed i 5 YVal�id ;tv o,f Permit. Thu issuance of a permit or' approval of ip fans.' sp.ecit,ioati.onst :and computations shall not be: cen- r x ; strued to .be .a uer�m�t for, or an approval of an_v.vio10 - 0 n of any of the pravi`si s of +the biii l.d:inu code or t �z'+ other; opd i,nance of'. tiie r ur,i'�d i c,t on . No perms t presuming to 7r p iv e: :auihci.rit'v:..to: viola or cance,i: the provisions cif thi code...shal,l Z e. val i•d s ; . a$a r. . A _.mss+' • r .. .. .. .. ... ?? ._ I hereby cert; that' I have read es the' :cond itions and wil 1 ,Comply: :.i'th3;ithem? as .o ut l i.ned 'A l 1 uro,v,is i one of r l aw and o i rian cep govern 1 no th is Jworkrwki 11,:be complied with: fr whether s "ied herein ut not }•' sl ` .. , r;'• 2 The • granting ` of this per i m t does"' not presumesto give authority to. violate+;: or' can cel'.,.the provis'ion's.: of any:. other work or lo cal laws reoula;ti�nq • truction or: the! "perf'o'rmance,- .rofo work. .d . U t 0/: S.ianatLire rint, Name: l * * * * * *a * * * ** ** * * * * * * * * * * * * * * ** * * * * * * * * * * * * ** * * ** * * * ** * * * * * * * * >• C ITY OE, : :TUKWILA !�A 1;71 ; -r " p 3 ( rRANSMIT * ******* 4******** * *t%* * * * * * ** * * * * * * * * * * * *#. * * * * ** TRANSMZT N. umber:: R0:i0032 ;Amount: 46.50.03/16/01 11 :44 p ayment Method: CHECK`. :Notation: AIC SERVICES in it:, JTD P ermit No: ' M01 -031 Type :`. B-MECH • MECHANICAL PERMIT P arcel Na: 262304 -9004 Si Addrress:::1018 SOUTHCENTER MALL Total Feed: 46.30 Mtis Payment 46.50 Total ALL Pmts. • 46.50 Balance. .00 *'****"** * ** * * * * * * * * * * * * * * * * ** * * A ccount Code Descr,i of i on Amount 0 00/341 .X3,0 .P i AN ;CHECK 7. NOt4RES 3.30 00 0/3 ; 2. 0.0 MECHANICAL NONRES 37.20 170 .' 03/20 971. Pro' t: �' � T Inspection: Ty of �� ' Ad ress:.. � " / L , 0.461 i t •Date called: 1,2. (01 Special instructions: ` ire ‘„ ', 3 a M- 1.. ' . \3C__-. Date wante .1 ��D' C, p.m. Requ er: Ph e P C -- i2 tf.vott, COMMENTS: Inspector INSPECTION RECe Retain a copy with permit -': INSPECTION NO. CITY TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila; WA 98188 Approved per applicable codes. PERMIT NO. Corrections required prior to approval. Date: ✓�1 $4 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt'No: Date: Project ....1.01: It . JIIL_. . Type of nspect Ari w...: U '' .r .. It Address: Date called: - . = Special instructions: Date wanted: Requester: - Phone: • INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. , INSPECTION RECD Retain a copy with permit PERMIT NO. (206)431 -3 r $47.00 REINSPECTION rREQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection• COMMENTS: • • i t Corrections required prior to approval. Receipt No: Date: • Pro'ect: • Type of In ectio . V ri c....wl • _ its: tz ..t44Cei Da called: L(f Date wante /___ - a3 Special instruct • /, i Re qS; t i j dai Phone: k L INSPECTION RECO Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 17 777 : . 1 7 ' • . !‘• PERMIT NO. (206)431-3670 (14 per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date:L 4 171 $47( REINSPECTIO REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blv ., Suite 100. Call to schedule reinspection. Receipt No: Date: 140,80 , 1 2 2editiGASiataiL FINALAPP FRM Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued S prinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: .Suite # • ,74•• 7 .sr.+1�` •. ••':,.: a r , t �: }. d d ! }, . aiir�i"�Nauie i Y'YY . . W i" , a. �� r.. -r i wi /'.#n` *'' ' } ^''1 4 ' "FC 1 ± r, r - - W d'j ecr: -� rK'^rr • TURWILA.FIRE.DEPARTMENT FINAL'APPROVAL.FORM (A/ of TUkwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Permit N T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 re w U O U) .„CO w; w o, g Q i v • • F. z i-: • . lD. ra ,O .0 W, H V ~ O ` w z U N H- =' • O F- z *LICENSE DETAIL INFORMATION Form STATE OF WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES Specialty Compliance Services Division P. O. Box 44000 Olympia, WA 98504 -4000 THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS: LICENSE DETAIL INFORMATION Current Filter: None Registration# or License ARCHIIC043CI Name ARCHITECTURAL INT /CNST SRV INC Address PO BOX 73397 Address City . PUYALLUP State WA Zip 98373 Phone Number 2538485948 Effective Date 2/21/96 Expiration Date 9/24/01 Registration Status ACTIVE Type CONSTRUCTION CONTRACTOR Entity CORPORATION Specialty Code GENERAL Other Specialties UBI Number 601676445 * * *VIEW PRINCIPAL OWNER(S) FOR THIS LICENSE* * * * * VIEW CONTRACTOR BOND /SAVINGS INFORMATION * * * * * "'CHECK INQUIRY FOR SUMMONS AND COMPLAINTS* * * *.* *VIEW CONTRACTOR INSURANCE INFORMATION * * * New inquiry by CITY, NAME, PRINCIPAL OWNER NAME, NUMBER, UBI NUMBER or return to the L &I Construction Compliance Home Page http: / /www.lni.wa.gov /CONTRACTORS /TF2Form .asp ?License= ARCHIIC043 C 1 Page 1 of 1 NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. I– MATERNITY SOUTH CENTER MALL, SEATTLE WA. MECHANICAL AND FIRE PROTECTION SPECIFICATIONS GENERAL Obtain and pay for permits and certificates of inspection. Within five clays of Contract award submit shop drawings for approval. When long delivery items require lead time submit shop drawings for preliminary approval by use of Fax transmission. Subsequently submit four . sets of shop drawings for 1. Ductwork modifications. 2. Supply Diffusers and Return Grilles 3. Fire suppression system modifications. Purchase long delivery items with order for expedited fabrication and delivery. Do not substitute specified equipment. materials or procedures until approved by the Architect. Notify the Architect in writing, within five days of Contract award that the specified equipment has been ordered and will be delivered and installed as outlined in the job construction schedule. Coordinate installation with other trades. Maintain installation to accommodate Architectural drawings and finishes. Report interferences for resolution. The systems must comply with applicable Codes and Authorities having jurisdiction. (A.H.J.) Bring conflicts to the Architect's attention during the bid period or incorporate conflicts in the Contract. Guarantee material, equipment and labor for one year after acceptance. Material and equipment, where applicable, must be U.L. Listed. Deliver the warranty documents to the Owner. Confirm electrical power characteristics prior to equipment purchase. Pay for repair "and replacement of work and material which fail during the warranty period. Pay for damage to the building, its contents or finishes due to failure of work and material installed in this Contract. Where material or equipment is replaced extend the warranty period for one year after the time of replacement or repair. Visit the site and be aware of conditions which may affect the Contract Bid. No addition to the Contract Bid will be accepted for field conditions if such conditions could have been observed by thorough site inspection. Failure to show or mention petty details shall not be warrant for omission of necessary appurtenances for the normal, usual and proper completion of the work. PROJECT WORK SCOPE A complete and operable Air Conditioning system exists in place. Modify / extend ductwork to the newly demised storage room. No modifications to the existing mop basin and water heater plumbing is required. Modify the existing • closed head wet sprinkler system to accommodate the new ceiling and lighting throughout. Comply with Architectural drawing requirements. Work is generally shown on this drawing, but not limited thereto. Perform the cutting and patching required to install the work. Expose and confirm the exact location of existing services and systems by field inspection prior to rough -in of the new work. DEMOLITION Relocate existing pipe. sewers, drains which infringe on the proposed store finishes and elevations. Remove unused piping and abandoned ductwork throughout. Cut unused services back to the service main and cap or plug. Cut back unused floor drains below the proposed new floor finish elevation and plug. Cut back cleanouts and ::reset to serve the existing sewers. EQUIPMENT AND MATERIAL DUCTWORK Install and configure the work to interface with other Trades and the Architectural finishes. Consult with other Trades and establish necessary space requirements for each Trade. Dimensions shown are net inside. Prior to duct fabrication accurately confirm the existing A.C. unit and ductwork location. Prepare ductwork construction shop drawing for approval and for subsequent fabrication. Fabricate ductwork of galvanized steel in accordance with low pressure Standards of ASHRAE and SMACNA, less than 2" we air distribution. branch duct plenum fittings or Provide c uct connect ions using P 9 conical_ spin -in fittings, Flexmoeter GCB or Acme with duct liner insulation guard, less volume damper. Fabricate round duct balance dampers of galvanized steel with Duro-Dyne type RB -25T locking support bearings at each side of the damper blade. At diffusers and diffuser plenums, use UL Listed Standard :81 Class 1 insulated flexible duct drops, Fiberglass 'Valuflex" or Gentle), SLR" with vapor barrier jacket maximum 4 feet long, installed only in straight 'runs without elbows, fully extended and supported. Seal with mastic and fasten with a nylon drove band. Brace ducts to insure rigidity and prevent vibration. Insure the ductworic throughout is continuous, secure and air tight. CEILING DIFFUSERS - Krueger .series PLO type 23 frame or Titus OMNI .type 3.frame with directional vanes, key .operated volume damper, 24" x 24" full face lay -in frame of neck size and capacity indicated. Where located in gypsum ceiling construction provide a Plaster Frame with lay -in diffusers.:: Provide with standard white baked enamel finish. GRILLES - Krueger series 580 H or Titus with : - lay -in border of size indicated. Provide with standard white baked enamel `finish. Face open blades towards the nearest well. INSULATION - Provide the work in accord with insulation manufacturer's recommendations installed in accordance . with the best practice of the trade and the standards of this criteria. Provide insulation with composite fire and smoke hazard ratings , within the limits of UL -723 testing method for Flame Spread of 25 and Smoke Developed. of 50. Provide vapor barriers with a continuous unbroken seal. Adequately insulate and vapor seal hangers and supports which ore fastened directly to cold surfaces. Prevent condensation throughout. Round supply A:C. ductwork; wrap ductwork with 1° thickness 3/4# density fiberglass bait with FRK facing. FIRE SUPPRESSION AND SPRINKLER SYSTEM Sub Contract to a licensed Sprinkler Trade. Modify the existing system to provide a closed head wet sprinkler system throughout. The suppression system must conform to NFPA end particularly to the respective chapters of NFPA 13, 231, 231C each as defined and modified and approved by the Underwriter of the Retail Store Tenant, the Landlord and Authorities having jurisdiction. Submit head layout for approval. Revise head layout as required by the Architect to maintain symmetry and head placement. Subject to approval of head and system layout size piping and provide hydraulic computations with reference points, on reproducible tracings for approval of the Underwriter, Fire Deportment, Water Department and Authorities', having jurisdiction. Obtain four sets of design drawings, approved and stamped by the Authorities having jurisdiction. Sprinkler system shall be modified as required to secure the best Possible insurance rates on building contents. Sales area and Storage Room : Recessed _ sprinkler heads with chrome plated escutcheon. Provide sprinkler head cage installation :where ceiling height is less than 8 feet or where the racks are within 24° of the ceiling. PIPING Install piping in accordance with NFPA 13 criteria and Fire Department requirements. No piping shall be installed at locations subject' to freezing. Suppression piping shall be steel; Copper tubing is not acceptable. Provide, locate and mount type ABC extinguishers throughout, number, size and locations as directed by the Fire Marshall. Pressure teat system at 200 psig for two hours, submit standard pressure test report "Material and Test Certificate" and obtain final approval of authorities having jurisdiction. Landlord's sprinkler main is active. Repair damage to the Landlord's sprinkler system, developed, in this Work Scope, sub-contracted only to the Landlord's sprinkler Trade. TESTS AND ADJUSTMENTS EXISTING A.C. UNIT Start up the existing A.C. system and confirm proper function.. Provide new fan belts and air filters. Clean evaporator coil, clean condenser coil, clean condensate pan, clean evaporator fan wheel and blades, lubricate throughout. Inspect, clean and tighten electrical power terminals, contactors and control terminals. Upon completion of this service schedule, provide a written report relative to the equipment condition and system operation. Make recommendations relative to additional service required for proper control and operational sequence. Adjust duct and diffuser dampers and the air handler fan speed to insure air distribution within 5% of the indicated volume. Provide a balance report for approval recording 1. final fan speed 2. evaporator fon static pressure 3. supply and return air duct static pressure external to the AC. unit 4. evaporator fan horsepower 5. temperature readings of outside air, return air, mixed air and supply air 6. air volume of each supply air diffuser. Include power running inspection and submit power operating voltage and amperage for each motor and compressor leg in comparison with unit nameplate. Confirm operation is within the . nameplate rating or shut down the un it prior to damage. Final air balance must be made with integral diffuser volume dampers open and at least one branch duct volume damper 100% open. Make initio" adjustment of air handler fan speed to preclude Successive noisy pressure drop at ceiling diffusers. Confirm unit temperature controls maintain the set point. Provide time to adjust air balance as additional air volume may be required in specific areas as will be field determined after the initial operating period. Should the A.C. unit be used during construction, provide new filters at time of Owner acceptance. Do not use the A.C. unit without filters in place under penalty of cleaning coils; ductwork and air distribution devices. EXST '7- -- - RELOCATE EXISTING THERMOSTAT EXISTING EXH GRILLE 10x10 FA. EXISTING EXH FAN EXST EXST i �. CAP\ EXST i DEMO EXH. GRILLE NEW 6" CD, 75 CFM, — 6" 0 DUCT . r TINE R C" ORASE ROOK 77 ,NE.-., RCOVS GNS�/rRAF — SPRINKLER M. "iN, BRANCHES, GRID AND HEADS EXIST IN PLACE. MODIFY / EXTEND THE EXISTING SPRINKLER GRID AND RELOCATE HEADS TO PROVIDE A COMPLETE CLOSED HEAD WET SPRINKLER SYSTEM THROUGHOUT SERVING THE NEW STORE LAYOUT, CEIUNG AND UGHTING MODIFICATIONS AS PER NFPA A LANDLORD INSURANCE UNDERWRITER CRITERIA AND AS PER THE SPECIFICATIONS. PROVIDE UPRIGHT HEADS IN AREAS WMI EXPOSED STRUCTURE PROVIDE SEMI- RECESSED HEADS WITH PAINTED ESCUTCHEONS IN GYPSUM CEILINGS EXISTING MOP BASIN, WATER HEATER AND FLOOR DRAIN TO REMAIN. =ILE COPY I understand that the Plan Cl p o 'al, are stitzt t orrors and omissions and approval of piers does - authorize t he violation of any adopted code or ordinance. Roceipt of con- tractor's copy of approved plans a cknowledged. ' I r 4 0 r,riacHANicAL --s AL GAS PiPiNG CITY OE TUiLLiVIL.A. REVISIONS ND CHANGE'S SHALL BE MADE TO OF ViC. WITHOUT PRA..?. TU..VIiLA BUILDING DIVITTZiit, .Y r Tn l'1 L r `E A NEW ' yJ fu'.0 I.wY INCLUDE ADDITE INAL PLAN REVIEW FEES. L LEGEND Y.C. E.C. G.C. OW Of CONTRACT /.CONNECT TO COSMIC MECHANICAL CONTRACTOR ELECTRICAL CONTRACTOR GENERAL CONTRACTOR MECHANICAL GENERAL NOTES VERY EXISTING CUNDDKNS. A. vlsrSITE ' TO BIDDING AND HELD E BE FAMILIAR WITH LANDLORD'S STANDARDS, RUES AND REGULATIONS. C. OBTAIN AND PAY FOR presto, LICENSES,. DOCUMENTS AND SERVICES RELATED TO INSTALLATION OF THE WORK D. AS. TRADE TO COORDINATE SPRN(LER SYSTEM WITH DUCTWORK AND l GHTS.. EXST EQUIPMENT ACU - SPLIT SYSTEM, CARRIER, 4 TON NOMINAL HORIZONTAL NR HANDLER - 1600 CFO, WITH 5 KW ELEC HEATER 57' MHN TOTAL. 39 MBA- SENSIBLE COOLING 30 A 208 v If fEMalE CONDENSING UNIT - MODEL. 38CK -O4e -5 30 A 208 V 3 f TEE.- COOK. GC -420, RESET SPEED TIP, BNANCE DAMPER TO 100 CFM REPLACE EXST RETURN GRILLES WITH - NEW 24x12 ALUM. EGGRATE GRILLES KRUEGER EGC -10 1 "x1 "x1" TYPICAL 4 I f ( T T i -- r l EXST I 'f �` f— EXSTi 1 L- L eP n CLEAN EXISTING CEILING - SUPPLY DIFFUSER, TYPICAL RLNAIN MECHANICAL PLAN 1/4" s 1'-O' PLUMBING / SPRINKLER PLAN 1/4' • I, -0'. 1 / - 7 ) PAUL COLTON : ASSOCIATES CONSULTING ENGINEERS 724'MARKIN BUILDING .1276: WEST THIRD. S1r¢tr CLEVELAND; OHIO 44113 TELEPHONE 218- 771 - 1121. FAX 218 -698 -3545 . e -mail pmpPAproPPecom:. Dale Issu0 12 -22 -00 B/P 1 -4-01 LL GOMMIgNTS 2-4 -01 LL GONIMENTS • • • • GERALD L.` HERSCHMAN ARCHITECT- - 2 6' 2 5i. COMMERCE PARK' CLEVELAND; OHIO 4 4 1 2 2., PHONE 216 - 464 -4144 T= AX 216.464- 6592;' - F -M0 arlboxd, hersahntana ra41 H.V,A,C, SCHEDULES SPLIT SYSTEM SPECIFICATIONS EXISTING MANUFACTURER CARRIER SATURATED SUCTION TEMP_ REFRIGERANT _F E.E.R. RATING SATURATED COND. TEMP F AIR ENTERING CONDENSER. Fdb CONDENSING UNIT AIR HANDLING UNIT EVAPORATOR COIL EXISTING EXISTING CARRIER EXISTING MODEL NO. CARRIER MODEL NO. 38CK- 048' -5 MODEL NO CARRIER WEIGHT lGT WEIGHT 2.70 AIR ENT: COIL 1 Fdb Fwb VOLTS /PHASE /HZ 208 V Ti VOLTS /PHASE /HZ 208 V 3M AIR LVG. COIL Fdb Fwb COMP PWR INPUT KW CFM 1600 ROWS CIRC FINS / "- TOTAL COOLING 48 BTUH TOTAL S.P. "WC TOTAL COOLING BTUH FAN RPM HP BHP SENSIBLE COOLING 000 PRESSURE' DROP "WC COIL FACE AREA SQ.FT. FACE VELOCITY FPM ' 5,140 -. - SEPARATE ELECTRIC DUCT HEATER SPECIFICATION MANUFACTURER EXIS I NG KW 5.0 STEPS 1 -VOLTS /PHASE /HZ '.208. V 2 CORRIDOR WALL TOILET EXHAUST FAN SPECIFICATION MANUFACTURER COOK CFM 1 WATTS /HP'. 87 V /PH /HZ 120 ! MODEL GC -420 STATIC PRESS. 0.2 "WC RPM 0.75 H.V.A,C, CAICUL_ATI'NN' F U BUILDING '62' SUMMER SPACE 76 ° F @ 500 R.H. OUTSIDE 84 °F db/ 68° F wk HEATS NG SPACE 72 ° F OUTSIDE 21° F ROOF "U" = 0.09 CLID = 68 HEAT LOSS SENSIBLE LATENT HEAT GAIIJ HEAT GAIN ITEM QUANTITY FACTOR BTU FAC FOR BTUH FACTOR .BTUH I. ROOF AREA G.L.. A. SO. - T. 4.59 5,140 -. - 5.33 _. 2 CORRIDOR WALL SOFT, 765 3. OUTSIDE WALL 0.75 TT 3 OUT STD E 'BALL SOFT 1734 CONNECTION 4.9 K.W. 4. LIGHTING YE CONNECTION K W. 5 PEOPLE '.. 3413 5. PEOPLE GLA /100 = PEOPLE " 315 : 325 6. APPLIANCES SEE APPLIANCE CALL FORM 8.64 1;555 680 1,224 7 G . A. 900 GL •U TST DE AIR GLA x .2 CFM/SS.FT. = CFM 5508 I '8.64 80 8. FA P MOTORS H P - 2545 26,310 3,024 TOTALS CFMI SENSIBLE BTUH -. 1360' CFM _... 1. 08X20 . 0 T XE)IE LIGHTING KW ENTRY SHALL MATCH FROM THE ELECTRIC LOAD SUMMARY ON 'EL EC TRICAL, DATA FORMS' TOTAL = ENSIBLE * LATENT)= BTUH COOLING REMARKS AT NI LIGHTING KA AY SHALL MATCH FROM THE ELECTRIC LOAD SUMMARY ON 'EL TRICAL DATA FORMS' WALL FAC OUTSIDE WALLS MDR EH= 4.08 EAST = 8.84 SOUTH`- 6:46 WEST .6.46 REMARKS' H,V.A,C. CAL-CULA T ION rORM PHASE I SUMMER SPACE 76 F H 507. R.H. OUTSIDE 84 F db/ 68 F wb HEATING SPACE 72 F OUTSIDE 21 F ROOF "U" = 0.08 CLID = 68 HEAT LOSS SENSIBLE LATENT HEAT GAIN HEAT GAIN ITEM QUANTITY FACTOR BTUH 'FACTOR BTUH FACTOR I BTUH 1. ROOF AREA G.L.A. 900 0 T, 4.28 '3,850 ' 5.71. 5,140 -. - 2. CORRIDOR WALL 252 SO ,F T. 4.76. 1,510 252 635 3. OUTSIDE WALL 0 SO. FT 17.34 0 4. LIGHTING 31E X CONNECTION 4.9 K.W. 3413.. 16,730 5 PEOPLE GLA /100 = 9 PEOPLE J 250.. 2250 200 1800 6. APPLIANCES SEE APPLIANCE CALC FORM 55.08 91915' 8.64 1;555 680 1,224 7 G . A. 900 GL x 2 CENT /SO .FT, =180 CFM B. FAN MOTORS 0 H.P. 2545, 0 " TOTALS 1a,96$ 26,310 3,024 TOTAL = (SENSIBLE + LATENT)= 29,334 BTUH COOLING - CFMI SENSIBLE BTUH -. 1360' CFM _... 1. 08X20 . 0 T XE)IE LIGHTING KW ENTRY SHALL MATCH FROM THE ELECTRIC LOAD SUMMARY ON 'EL EC TRICAL, DATA FORMS' WALL FACTOR OUTSIDE WALLS ' NORTH= 3.40 EAST =10.88 SOUTH = 5,44 WEST - 3,74' REMARKS moo 0 CI s A. HVAC C. TENANT TO FURNISH AND INSTALL ROOF TOP UNIT(S) SIZED PER SENSIBLE /TOTAL CALCULATION FORM. HEATING MAY BE GAS OR ELECTRIC FOR BUILDING "0 - TENANTS. GAS IS AVAILABLE ON ROOF. TENANT SHALL OBTAIN GAS METER FROM LOCAL UTILITY AND INSTALL PER UTILITY COMPANY REQUIREMENTS. SEE LANDLORD'S DRAWINGS FOR GAS METER LOCATION. COOLING SHALL BE ELECTRIC. LOW AMBIENT OR AN ECONOMIZER CYCLE IS REQUIRED ON ALL RILES. 2. TENANT SHALL FURNISH AND INSTALL A SMOKE RELIEF • I SHALL BE SIZED AS INDICATED ON CALCULATION TENANTS WITH ECONOMIZER MAY UTILIZE HV•' RELIEF_ PLUMBING LANDLORD ROV • SANITARY, GAS A ND DOMESTIC WATER SERVIC . OR TENANTS • TILIZE. SEE L ANDLORD'S DRAWINGS WATER METER 15 REQUIRED BY ALL TENAN . TENANT TO PURCHASE WATER METER FROM LOCAL UTILITY INSTALL PER UTILITY COMPANY REQUIREMENTS PROVIDE METER W •EMOTE READOUT AS REQUIRED. ALL INSTALLED EQUIPMENT, ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIPED. SOUTHCENTER MALL BUILDING '02' SYSTEM DESCRIPTIONS SPRINKLER TENANT SHALL FURNISH A WITHIN THE LEASED •' POINT. 3. PROVI, DOOR FO SOUTHCENTER MALL SEATTLE WA. MAIN WO RCP !LE NAME SCNTTM1 THIS SHEET & TTG -01 MUST BE INCLUDED AS PART OF TENANT'S SUBMITTALLTO THE LANDLORD, ' BIDDING CONTRACTORS AND FOR BUILDING PERMITS WNO NIEmk TTM -1 4/20/98 1/15/96 6/13/95 SEARS ISOLATOR -MASON INDUSTRIES TYPE 30N SPRING HANGERS SIZE EACH HANGER ASSEMBLY FORA MIN. CAPACITY OF 120X OF THE INSTALLED WEIGHT. DOUBLE NUT 141 2' 0.0. ( P AM mICK WASHER (PEP) MIN. 2'x2'»1 n NGLE SUPPORT (MIN.)' 0 4691E P4R .. EQUIP MFR. REQUIREMENTS 5' -0" O.C. MAX. ATTACH TO'. EACH JOIST. METHOD #1 USE THIS METHOD ONLY WHEN SPACE EXISTS BETWEEN ANGLES FORMING BOTTOM CHORD. KEY PLAN NO SCALE JOIST PANEL POINT AHU. TERMINAL BOX. ETC. SECURE UNIT TO!ANGLES WHEN HANGER ROD PftOJF.0 iS DEYOND JCIST MORE THAN fi EXTEND ANGLE t0 NEXT JgST METHOD #2 4. DO NOT DRILL HOLES IN EXISTING STRUCTURAL MEMBERS UNLESS APPROVED BY LANDLORD IN WRITING. 5. UNLESS INDICATED OTHERWISE ON STRUCTURAL DRAWINGS: A UNITS UP TO.IB80 LBS. TOTAL WEIGHT SHALL BE SUPPORTED ON A MINIMUM OF TWO (2) JOISTS. B UN. GREATER TFAN 1880 LBS. BUT LESS THAN 2800 LBS. TOTAL WEIGHT SHALL BE SUPPORTED ON AMINIMUM OF THREE (3) JOISTS. C MAXIMUM TOTAL WEIGHTOF ONE UNIT IS 2800 LBS. EQUIPMENT SUPPORT DETAIL 35 N.T.S. TT -35 3'.3'.1/4" r NNGIE SUPPORT(MIN.) AERVYWS JCPFHEY ' NOTES: 1. OV FlELD VERIFY LNDLORD'S APPROVED LOCATION OF H.V.AC. EQUIPMENT WITH LANDLORD'S REPRESENTATIVE BEFORE P 2. SEE STRUC2DOgT. URE DRAWINGS FOR H.VA.C. EQUIPMENT AND REINFORCED JOIST LOCATIONS FOR EQUIPMENT ER 3. SIZE OF STRUCTURAL SUPPORTS (RODS, ANGLE ETC. ARE MINIMUMS AND SHALL BE RE512ED BY TENANT OR TENANT CONTRACTOR AS REWIRED FOR PROPER SUPPORT AND STRUCTURAL INTEGRItt. CLAMP ArvGLE O JOIST OF JOIST PHASE I A HVAC B. PLUMBING SOUTHCENTER MAI L PHASE I SYSTEM DESCRIPTIONS 1. TENANT TO FURNISH AND INSTALL SPLIT SYSTEM HEATING AND AIR CONDITIONING UNIT(S), SIZED PER SENSIBLE /TOTAL CALCULATION FORM. HEATING SHALL BE ELECTRIC FOR PHASE I TENANTS. GAS IS NOT AVAILABLE. TENANT SHALL CONNECT TO LANDLORD PROVIDED OUTSIDE AIR DUCT WHERE PROVIDED FOR MINIMUM FRESH AIR REQUIREMENTS, OR INSTALL AN OUTDOOR AIR INTAKE THROUGH ROOF. INSULATE DUCTWORK PER LANDLORD'S REQUIREMENTS. WHERE TENANT'S ELECTRIC HEATING REQUIREMENT EXCEEDS 6 KW A HEAT PUMP IS NEEDED AS PER WASHINGTON STATE 1994 ENERGY CODE. 2. TENANTS SHALL INSTALL TOILET ROOM INCLUDING EXHAUST FAN AND EXHAUST DUCT UP TO ROOF EXHAUSTER, TENANT SHALL FURNISH AND INSTALL A COMPLETE TOILET ROOM WITHIN THE LEASED PREMISES. LANDLORD HAS PROVIDED D. SANITARY AND DOMESTIC WATER CONNECTIONS FOR TENANTS TO UTILIZE TENANTS SHALL RUN A 4" VENT THRU ROOF. TOILET ROOMS SHALL CONFORM WITH ADA REQUIREMENTS AND THE REQUIREMENTS OF THE LANDLORD. 2 2. WATER METER IS REQUIRED BY ALL TENANTS TENANT TO PURCHASE WATER METER FROM LOCAL UTILITY AND INSTALL PER UTILITY COMPANY REQUIREMENTS. PROVIDE METER WITH REMOTE READOUT AS REQUIRED. ALL INSTALLED EQUIPMENT, ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. C. SPRINKLER 1. TENANT SHALL FURNISH AND INSTALL A SPRINKLER SYSTEM WITHIN THE LEASED PREMISES FROM THE LANDLORD'S CONNECTION POINT. 2. SPRINKLER IS REQUIRED ABOVE CEILING AT ALL ELECTRIC MOTORS AND IN RHO MIXING BOX. 3. ALL DESIGN SHALL BE APPROVED BY ALL AUTHORITIES HAVING JURISDICTION, THE LANDLORD AND FACTORY MUTUAL. THE LANDLORD'S UNDERWRITER IS: FACTORY MUTUAL DISTRICT OFFICE 10900 NE 4th ST. SUITE 700 P.O. BOX 96077 BELLEVUE, WA. (206)- 454 -3931 98009 -9677 SMOKE DETECTION SYSTEMS TENANT SHALL INSTALL A SMOKE DETECTOR IN THE SUPPLY AIR SECTION OF THE AIR HANDLING UNIT(S). UPON DETECTION OF TENANT SMOKE THE SMOKE DETECTOR SHALL SHUT DOWN THE HVAC SYSTEM(S) AND REPORT TO AN UNDERWRITER'S LABORATORIES LISTED CENTRAL STATION MONITOR. 3. PROVIDE REMOTE TEST - ALARM -RESET SWITCH /LIGHTS AT REAR DOOR FOR SMOKE DETECTOR 6 L.E.D. IN SALES AREA CEILING TO NOTIFY M.G.R. WHEN SMOKE DETECTOR IS ACTIVATED. Q NORDSTROM SEARS KEY PLAN NO SCALER / BUILDING 'G2' M. RELIEF AS SMOKE H,V, ' , HEDIULES EFTOP UNIT '.(RT SPECIFICATIONS'. CAPACITY. (AT AR. '.. CONDITIONS) AIR EN RING'I CONDENSER 95 FAA AIR ENT NGI. EVAPORATOR Fdb.! Fwb TOTAL COO NG CAPACITY BTUH SENSIBLE. COQ ING CAPACITY BTUH COMPRESSOR I ' UT KW HEATING CAPACIT GAS (YES) (NO) INPUT MANUFACTURER MODEL VOL TS /PHA SE /HERTZ EE R RATING TOTAL AT. L BS EVAPORATOR F' PERFORMANCE F M'. E X TE RNAL :. 'WC MO H "HP OUTDID AIR (MIN.) CFM ACC SORIES OUTPUT. E 4NOMIZER (YES) (ND) OR LOW AMBIENT CONTROL TO 0 F (YES) (NO) AC RELIEF (GRAVITY)(PYR) HP DOWNTURN PLENUM ANTI-SHORT. CYCLE TIMER '' CHANGEOVER T'STAT TH FULL PERIMETER CURB 'CRANKCASE HEATER. HEM T -COOL -AUT 0 - OFF AND THROWAWAY FILTERS 5 - YR. COMP !WARRANTY. FAN-AUTO-ON-SWITCHES IN SUB - ASE SEPARATE POWERED HVAC /SMOKE RELIEF FAN SPECIFICATION MANUFACTURER CFM V /PH /HZ HP MODEL STATIC PRESSURE 'WC ::DRIVE (DIRECT)0R(BELT)__RPM MINIMUM CFM CALCULATIONS LEASABLE AREA 9115 GEM/SOFT CFM NOTE MINIMUM STATIC PRESSURE', SHALL BE 25' W.C. I S TALL A SP RINKL S YSTEM ISES FROM THE LANDLORD ER CONNEC R IS REQUIRED ABOVE CEILING AT ALL ELECTRIC ORS AND IN AHU MIXING BOX. '`LL DESIGN SHALL BE APPROVED BY ALL AUTHORITIES HAVING JURISDICTION, THE LANDLORD AND FACTORY MUTUAL. THE LANDLORD'S UNDERWRITER IS: FACTORY MUTUAL DISTRICT OFFICE 10900 NE 4th ST. SUITE 700 P.O. BOX 96077 BELLEVUE, WA (206)- 454 -3931 98009 -9677 D. SMOKE DETECTION SYSTEMS 7. TENANT SHALL INSTALL A SMOKE DETECTOR IN THE SUPPLY AIR SECTION OF THE ROOF TOP UNIT(S). 2. UPON DETECTION OF TENANT SMOKE THE SMOKE DETECTOR SHALL HI IT DOWN THE HVAC SYSTEM(S). SOUND AN AUDIO /VISUAL ALARM HORN LOCATED AT THE FRONT OF THE STORE AND REPORT TO AN UNDERWRITER'S LABORATORIES LISTED CENTRAL STATION MONITOR. EMOTE TEST- ALARM - RESET SWITCH /LIGHTS AT HEAR OKE DETECTION SYSTEM. SOUTHCENTER SEATTLE WASNNOTON MECHANICAL DETAILS AND SPECIFICATIONS Sheet 1 of 6 ri The Richard E. Jacobs Group °CAW" SOUTHCENTER MALL RECEINP OFY OF MIT CENTER VAC SCHMULES ROOF DP UNIT (•� CATIONS MANUFACTURER COOLING CAP • ITV MODEL AIR ENTERING .. ONDENSER FAA VOLTS /PHASE /HERTZ AIR ENTERING E • PORATDR Fdb/ Fwb EER RATING TOTAL COOLING C ACTT BTUH TOTAL WT. LB SENSIBLE COOLING : PACITY BTUH EVAPORATOR FAN PERFORMANCE COMPRESSOR INPUT KW' CFM MLA TING CAPACITY EXTERNAL S.P. ELECTRIC (YES) (NO) GAS (YES) (NO) MOTOR H.P. HP KW INPUT. OUTSIDE AIR (MIN.) CFM STEPS OUTPUT ACCESSORIES ECONOMIZER (YES) 11 1 OR LOW AMBIENT CONTROL TO 0' (YES) (NO) HVAC R E L I E F (A T Y) (PWR) HP DOWNTURN PLENU ANTI -SHORT CYCLE TIMER AUTO - CHANGEOVER T'S TAT. WITH FULL PERIMETE• CURB CRANKCASE HEATER HEAT -COOL -AUTO -OFF AND THROWAWAY F TERS 5 -YR. COMP. WARRANTY FAN - AUTO -ON- SWITCHES IN SUB- BASE TOILET EXHAUST FAN SPECIFICATION ANUFACTURER CFM WATTS /HP V /PA /HZ \\ MODEL STATIC PRESS. WE RPM. 2.52 SEPARATE POWERED HVAC /SMOKE RELIEF' FAN SPECIFICATION MANUFACTURER CFM V /PEI /HZ HP MODEL STATIC PRESSURE — 'WC DRIVE I(DIRECT)OR(BELT) I RPM. MINIMUM CFM CALCULATIONS LEASABLE AREA x 15 CFM /SOFT EPA NOTE: MINIMUM STATIC PRESSURE SHALL BE 25'... W.C, - H,` ,'� C CAL CUL1 ICF,I F ❑RM Ill PHASE Il SUMMER SPACE 76° F A 50 R.H. 'OUTSIDE 84 F AW/ 68° F wb '.HEATING SPACE 72° F OUTSIDE1. V1° F ROOF�U•• - 0.05 = 68 HEA? LOSS SENSIBLE LATENT HEAT :GAIN '.HEAi GAIfJ 1 �1 -- - CI_TD ITEM QUANTITY FACTOR BTUH FACT OR BTUH FACTOR BTUH ___ __ 1 ROOF AREA ____ G.L.P. SQ.F 7. 2.55 '.; 34 1 j 2. CORR[OOR WALL I SD.FT. 476 2.52 DurstDE wALL saFr i 230 _ I '31E 1 4. L. HT(tJG 3f � CONNECTION K.W. ,3413 GLA /100 = PEOPLE ..315 325 5. PEOPL 6. APPLIANC SEE APPLIANCE CALC FpRM'. UU TSIDC AIR GLA >< 2 CFM;'SOFT.= CFM '5508 664 6:80 FAN MOTORS H.P, ' 2545 ' � 8. pTALS 1 _ rr TOTAL = (SENSIBLE_ + _ TENT)= BTUH CDULfNG � . �E Xc LIGHTING KW [NTRY SHALL TCH FROM THE ELECTRIC LOP.D�'�VjgLL SUMMARY DN 'ELECTRICAL DAT FpRM$' FACT OUTS( ➢E WALLS NORTH= 0.50 � SOUTH-. OCS REMARKS — — KEY PLAN NO SCALE INCLUDING EXHAUST DLORD PROVIDED CENTRAL CONTROL SHALYEURNISH AND INSTALL A SPRINKLER SYSTEM LEASED PREMISES FROM THE LANDLORD'S CTION POINT. 2. ALL DESIGN SHALL BE APPROVED BY. ALL AUTHORITIES HAVING JURISDICTION, THE LANDLORD AND FACTORY MUTUAL. THE LANDLORD'S UNDERWRITER IS: FACTORY MUTUAL DISTRICT OFFICE 10900 NE 4th ST. SUITE 700 P.O. BOX 96077 BELLEVUE. WA. (206) - 454 -3931 98009 -9677 FIRE DETECTION AND SMOKE CONTROL SYSTEMS (FDSCS) TENANT SHALL INSTALL A SMOKE DETECTOR IN THE SUPPLY AIR SECTION OF THE ROOF TOP UNIT(S( AND AT STORE FRONT. ADDITIONAL SMOKE DETECTOR'S ARE REQUIRED EVERY 30' -0" OPEN STORE FRONT. TENANTS SHALL FURNISH AND INSTALL A SMOKE RELIEF FAN. \TENANTS ROL SH OF ALL THE FU KE RE AIJD LIE F FA INSTALL A STARTER FOR OHITN. 3. TENANT TO F ' • SH AND INSTALL A FIRE DETECTION AND SMOKE CONTROL TEM. ALL COMPONENTS TO BE SAME AS LANDLORD'S EXIS. . INTERFACE BETWEEN LANDLORD'S SYSTEM TO SHUT DOWN T • • XTS' HVAC SYSTEM AND ENERGIZE TENANT'S SMOKE REL FAN. SEE TTE DRAWING FOR SCHEMATIC. 8. FAN. MDT ROOF "LC — I 0:09 a LIGHTING 31E .31E. PEOPLE PPLIANCES', TOTALS REMARKS: COOLING GLA /100 QUANTITY' CONNECTION K SEE APPLIANCE CALC FOR TENANT TO FURNISH AND INSTALL ROOF TOP UNIT(S) SIZED PER SENSIBLE /TOTAL CALCULATION FORM. HEATING SHALL BE GAS FOR FOOD COURT TENANTS. GAS IS AVAILABLE ON ROOF. TENANT SHALL OBTAIN GAS METER FROM LOCAL UTILITY AND INSTALL PE UTILITY COMPANY REQUIREMENTS SEE LANDLORDS DRAWN OR GAS. METER LOCATION. COOLING SHALL BE ELECTRIC. AMBIENT CONTROL MUST BE UTILIZED. ECOMOMIZ OT PERMITTED. 2. TENANT SHALL FURNISH AND INSTAL SMOKE RELIEF. FANS SHALL BE SIZED AS INDICATED CALCULATION FORM. AMOLORD HAS PROVIDET WATER SERVICES FOR FOOD LANDLORD'S DRAWINGS FOR LOC 2. WATER METER IS REQUIRED BY ALL FOOD C TENANTS. TENANT TO PURCHASE WATER METER FROM LOCAL UTILI D INSTALL PER UTILITY COMPANY REQUIREMENTS. PROVIDE METE H REMOTE READOUT AS REQUIRED. 2. ALL INSTALLED EQUIPMENT, ACCESSORIES, AND PIPING SHALL DE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. V.A 1 CALCULA7 I ❑N H 500. R.N. G I B UTSIDE ° F. db/ 6B °F wb HEATING SPACE 72 ° F SO.F T SOFT. PEOPLE FACTOR 17'.34 SOUTHCENTER MALL FOOD COURT SYSTEM DESCRIPTIONS \V CIE 3M LIGHTING KW ENTRS.HALL MATCH FROM THE ELECTRIC LOAD SUMMARY ON "ELECTR(J AL DATA FORMS' NITARY, VEND, GAS AND DOMESTIC 1 RT TENANTS TO UTILIZE. SEE R -ON OF SERVICES. BTUH FACTOR FACTOR BTUH (FACTOR SPRINKLER TENON LL FURNISH AND INSTALL A SPRINKLER SYSTEM IN THE LEASED PREMISES FROM THE LANDLORD'S CONNECTION POINT. ALL DESIGN SHALL BE APPROVED BY ALL AUTHORITIES HAVING JURISDICTION. THE LANDLORD A.ND FACTORY MUTUAL. SMOKE DETECTION SYSTEMS TENANT SHALL INSTALL A SMOKE DETECTOR IN THE SUPPLY AIR SECTION OF THE ROOF TOP UNIT(S). UPON DETECTION OF TENANT SMOKE THE SMOKE DETECTOR SHALL SHUT DOWN THE HVAC SYSTEM(S), SOUND AN AUDIO /VISUAL ALARM HORN LOCATED AT THE FRONT OF THE STORE AND REPORT TO AN UNDERWRITER'S LABORATORIES LISTED CENTRAL STATION MONITOR. l P . R , O ,, V � IDE REMOTE TEST — ALARM —RESET SWITCH /LIGHTS AT REAR UNAR FOR SMOKE DETECTION SYSTEM. FOOD COURT OUTSIDE I2 °F LATENT HEAT GAIN OUTSIDE WALLS NORTH= 4.08 EAST 8.84 SOUTH= 6,46 WEST 6.46 HVAC �:IHEDULES ROOFTOP [ • NI T (R SP MANUFACTURER COOLI _I CAPACITY (AT AR CONDITIONS MODEL AIR EN RING 95 Edo VOLTS /PHASE /HERTZ [ AIR ENTE• NG EVAPORATOR'. FXA4 ' Fwb EER'RATING TOTAL COOL G''. CAPACITY' BTUH TOTAL WT. LBS:1 SENSIBLE CO•. INC CAPACITY BTUH EVAPORATOR. FAN PERFOANC COMPRESSOR IN" T KW CFM HEATING CAPACITY EXTERNAL S P' WC GAS (YES) (NO)' MOTOR H.P _� HP INPUT OUTSIDE AIR (MI CFM OUTPUT ACCESSORIES ECONO .(YES) (NO). OR LOW AMBIENT CONTROL TO 0 E (YES) (NO) HVAC REL ' F '.(GRAVITY), CPWR) HP 1 DOVNTU' PLENUM ANTI -SHORT CYCLE TIMER, AUTO- CHANGEOVER T'STAT TH FULL P RIMETER CURB CRANKCASE HEATER .HEAT- COOL -AUTO DFF AND THRII AWAY FILTERS 5 YR '.COMP WARRANTY FAN AUTO ON- SWITCHES'IN SUB '•SE KITCHEN EXHAUST FAN MANUFACTURER MOTOR H.P. CFM POWER V/ HZ PH MODEL FAN R.P M. ESP DRIVE BELT MOUNTING,. ; (CURB) FAN I P IF C T I O N SEPARATEPOWERED HVAC /SMOKERELIEF. . S EC i A 1 F FM V /PH' %HZ : P MANE OCTOBER C 1 1 — MODEL '' 'I ER PRESSURE �'WC DRIVE RPM I MINIMUM. CFM CALCULATIONS, � 1 1 I Il l i' AREA [ o 1 ,CFM /SQ FT. CFM LEASABLE NOTE MINIMUM STATIC PRESSURE SHALL BE !25' W C. I THE LANDLORD'S UNDERWRITER I5: FACTORY MUTUAL DISTRICT OFFICE 10900 NE 4th ST. SUITE 700 P.O. BOX 96077 BELLEVUE, WA. (206) -454 -3931 98009 -9677 3 REVISED REVISED TTM- 6/13/95 I ' PHASE II MERVYN'S HVAC C. TENANT TO FURNISH AND INSTALL ROOF TOP UNIT(S) SIZED PER SENSIBLE/TOTAL CALCULATION FORM. HEATING MAY BE GAS OR ELECTRIC FOR PHASE II TENANTS. GAS I5 AMIABLE ON ROOF. TENANT SHALL OBTAIN GAS METER FROM LOCAL. UTILITY AND INSTALL PER UTILITY COMPANY REQUIREMENTS TENANT SHALL ROUTE GAS SERVICE TO THEIR SPACE AND EOUIPMENT WIT THEIR SPACE. SEE LANDLORD'S DRAWINGS FOR GAS SERVICE LOCATION. COOLING SHALL BE ELECTRIC. LOW AM OR AN ECONOMIZER CYCLE 15 REQUIRED 0 HVAC ANTS SHALL INSTALL TOILET R FAN H E %HAUST DUCT TO TOILET UST SYSTEM P LUMBING SOUiHCENT ER MALL PHASE II SYSTEM DESCRIPTIONS yw+' SHALL FURNISH AND • TALL A COMPLETE TOILET ROOM D HIN THE LEASED PREMISES. [LORD HAS PROVIDED SANITARY AND DOMESTIC wATER CON TONS FOR TENANTS TO UTILIZE. TENANTS SHALL RUN A VENT TO •• DLORD'S VENT SYSTEM. TOILET ROOMS SHALL CONFORM WITH '.• REQUIREMENTS AND THE REQUIREMENTS OF THE LANDLORD. WA -, ER METER IS REQUIRED BY ALL LARGE WATER USING TEN TENANT TO PURCHASE WATER METER AND INSTALL PER LANDLORD'S REQUIREMENT, ALL INSTALLED EQUIPMENT, ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTAL;. ATION DETAILS TO CONFORM AS REQUIRED SPRINKLER TENANT SHA WITHIN FOOD COURT SOUTHCENTER SEATTLE. WASH/MOTOR MECHANICAL DETAILS AND SPECIFICATIONS Sheet 2 of 6 UNIT NUMBER THI5 SHEET & 0T0 -01 MUST BE INCLUDED AS' PART'. OF TENANT'S SUBMITTAL TO' THE 1 I' LANDLORD; BIDDING 1 CONTRACTORS AND FOR BUILDING PERMITS The Richard E. Jacobs ,Group l .. 1 SOUTHCENTER MALL !PERMIT CENTER GENERAL. A. ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH ALL APPLICABLE CODES AND LANDLORD'S MINIMUM REQUIREMENTS AS STATED HEREIN; IN THE LEASE) AND /OR IN THE TENANT MANUAL. CODE REQUIREMENTS, IF MORE RESTRICTIVE THAN LANDLORD REQUIREMENTS, SHALL TAKE PRECEDENCE. AND VICE /VERSA. C. D. ALL WORK SHALL BE PERFORMED AS INDICATED ON DRAWINGS UNLESS FIELD CONDITIONS REQUIRE MINOR CHANGES TO BE MADE. MINOR CHANGES SHALL BE MADE VITH NO ADDITIONAL COST TO THE TENANT. E. G. H. WHERE THE TENANT ELECTS TO RE -USE, AND THE LANDLORD HAS APPROVED THE RE -USE OR RENOVATION OF AN EXISTING HVAC AND /OR PLUMBING SYSTEM, REPAIR OR REPLACE ALL OR PART OF THE HVAC AND /OR PLUMBING EQUIPMENT TO ENSURE PROPER AND EFFICIENT OPERATION OF THE SYSTEM S), ENSURE THE HVAC SYSTEM IS CAPABLE OF MAINTAINING THE SPACE TEMPERATURES WITHIN THE LEASED PREMISES IN ACCORDANCE WITH ;THE LANDLORD'S, LOCAL, STATE, AND FEDERAL REQUIREMENTS, AND PROVIDE , WRITTEN CONFIRMATION TO LANDLORD OFI ALL WARRANTIES IMPLIED. N. :TENANT ELECTS NOT TO RE -USE EXISTING EQUIPMENT, CONDUIT, PIPING OR FIXTURES INCLUDING BUT NOT!, LIMITED TO ANY ROOF' MOUNTED EQUIPMENT, TENANT SHALL Ai TENANT'S EXPENSE REMOVE SUCH PARTS OF THE SYSTEM AND EQUIPMENT NOT BEING RE -USED INCLUDING CURBS .AND UTILITY SERVICES TO SUCH EQUIPMENT, CAP ALL PIPING AT LANDLORD MAINS. TENANT SHALL PERFORM ALL NECESSARY REPAIRS TO THE ROOFING SYSTEM AND /DR ADJACENT CONSTRUCTION IN ACCORDANCE WITH THE LANDLORD'S CRITERIA ANDDETAILS INDICATED ON LANDLORD'S MECHANICAL DETAILS AND SPECIFICATIONS DRAWINGS. O. PLUMBING AN SPECIAL CONDITIONS A TENANT'S GENERAL GENERAL D S UIR EM L TIN➢1 IONS OF AI 207 AND ENAN S GE . L CONDITIONS P.ECUIRF_NTS SHALL APPLY UNLESS OTHERWISE NOTED. ALL WORK SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE OF WORK BY THE TENANT AND THE LANDLORD. ACTUAL LOCATIONS OF LANDLORD'S SERVICES MUST BE FIELD VERIFIED. CHANGES TO CONFORM TO LANDLORD'S SERVICE LOCATIONS SHALL BE MADE AT NO ADDITIONAL COST TO THE TENANT AND /OR LANDLORD. MANUFACTURERS' NAMES ON WHICH THIS SPECIFICATION IS BASED INDICATE THE MINIMUM QUALITY OF PRODUCT REQUIRED BY LANDLORD. SUBSTITUTIONS MAY BE MADE TO THOSE SPECIFIED IF DEEMED EQUIVALENT BY LANDLORD. ITEMS NOT SPECIFIED HEREIN SHALL MEET LANDLORD'S APPROVAL. IF A CONFLICT OCCURS, THE LANDLORD SHALL RESOLVE SUCH CONFLICT AND THE TENANT'S CONTRACTOR SHALL CONFORM TO THE LANDLORD'S DECISION, SUBMIT SHOP DRAWINGS OF ALL MAJOR EQUIPMENT FOR APPROVAL SUBMITTALS SHALL INCLUDE AIR AND WATER BALANCE REPORTS. AS BUILT DRAWINGS - PREPARE AND SUBMIT TO LANDLORD AND TO TENANT 'AS BUILT' DRAWINGS INDICATING THE EXACT LOCATION OF ALL DUCTWORK, PIPING, AND ALL EQUIPMENT INCLUDING THE EQUIPMENT'S 'AS INSTALLED' SIZE(S), MANUFACTURER, MODEL NUMBERS AND PERFORMANCE RATINGS. SUPPORTS - EQUIPMENT, PIPING, DUCTWORK. OR ANY OTHER ACCESSORY SHALL NOT BE SUPPORTED FROM LANDLORD'S CEILING, SOFFIT. NEUTRAL PIERS, PIPING, DUCTWORK, METAL ROOF DECK, LATERAL BRACING, BRIDGING, OR CONDUIT. ITEMS SHALL ONLY BE SUPPORTED FROM STRUCTURE WHICH HAS BEEN APPROVED BY LANDLORD FOR SUPPORT. ALL ROOF WORK, PENETRATIONS AND REPAIRS SHALL BE TOTALLY PERFORMED 4 . RFORM ONLY ED AT THE TENAIT' THOSE ROOFING CONS E APPROVED BY LANDLORD AND SHALL BE PE TRACTORS XPENSE. INSTALLATION OF ALL ROOF MOUNTED EQUIPMENT SHALL BE COORDINATED WITH LANDLORD'S DESIGNATED REPRESENTATIVE. TENANT'S CONTRACTOR SHALL PAY FOR ALL FEES ASSOCIATED WITH THE CONSTRUCTION OF THE SPACE INCLUDING BUT NOT LIMITED TO: UTILITY COMPANY CONNECTIONS, SERVICE AND /DR TAPPING FEES LOCAL, COUNTY, OR STATE SERVICE CHARGES, INSPECTION CHARGES AND PERMIT FEES, LANDLORD'S CONNECTION FEES, LANDLORD'S UTILITY CHARGES.LANDLORT S METERING CHARGES AND /OR LANDLORD'S EQUIPMENT CHAPGES. DEFICIENCIES AND NON- CONFORMING ITEMS - IF, AT ANY TIME DURING THE TERM OF THE LEASE, LANDLORD DETERMINES TENANT'S EQUIPMENT OR SYSTEM HAS NOT BEEN INSTALLED OR IS NOT OPERATING IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS OR LANDLORD'S REQUIREMENTS, LANDLORD MAY, IN ADDITION TO ANY OTHER RIGHTS AND REMEDIES IT MAY HAVE, AFTER GIVING FIVE (5> DAYS WRITTEN NOTICE TO TENANT OF ITS INTENTION TO DO SO, CORRECT SUCH DEFICIENCIES AS LANDLORD MAY ELECT TO PERFORM FOR AND ON TENANT'S BEHALF. TENANT SHALL REIMBURSE LANDLORD FOR ALL COSTS INCURRED BY LANDLORD FOR THE CORRECTION OF THE DEFICIENCIES PLUS A FIFTEEN PERCENT (A570 ADMINISTRATIVE CHARGE. THE TOTAL AMOUNT SHALL BE DUE AND PAYABLE 70 LANDLORD UPON DEMAND. FOR INSTALLATION OF EQUIPMENT, CONTRACTOR SHALL CONFORM TO LANDLORD'S DETAIL DRAWINGS AND MECHANICAL DETAIL AND SPECIFICATIONS DRAWINGS. PLUMBING SERVICES HAVE BEEN PROVIDED FOR TENANT'S USE. TENANT SHALL EXTEND SERVICES PER, AND LANDLORD'S REQUIREMENTS. SEE LANDLORD'S BUILDING DRAWINGS FOR LOCATION. THE LANDLORD HAS PROVIDED A DOMESTIC' WATER, SANITARY VENT AND SANITARY SERVICE. THE TENANT SHALL CONNECT TO THE SERVICES. (MANDATORY) TENANT SHALL EXTEND SERVICE PER LANDLORD REQUIREMENTS. NO PIPING SHALL BE INSTALLED IN DEMISING WALL. A HANDICAPPED ACCESSIBLE TOILET ROOM IS REQUIRED IN EACH TENANT SPACE, EXCEPT FOOD COURT AND G2 AREA TENANTS. G2 AREA TENANTS WHO ELECT AND ALL NON-FOODCOURT TENANTS WHERE SAME DOES NOT EXIST, FURNISH AND INSTALL A MINIMUM OF ONE WATER CLOSET, ONE LAVATORY, ONE FLOOR DRAIN, ONE 6- GALLON WATER HEATER, AND ALL OTHER REQUIRED EQUIPMENT RED MATERIAL AND FOR A CD LE MP T E TOILET 'T I T ROOM. TOILET' E ROOMS SHALL BE AS REQUIRED BY APPLICABLE CODES AND ADA MATERIALS ALL MATERIALS SHALL IBE NEV. USED MATERIAL SHALL NOT BE PERMITTED. GAS PIPING a. SCHEDULE 40 BLACK STEEL PIPE WITH MALLEABLE SCREWED FITTINGS INSTALLED PER LANDLORD'S, STATE AND LOCAL AUTHORITIES', AND THE UTILITY COMPANY REQUIREMENTS. GAS COCKS 2' AND SMALLER SHALL BE SCREWED IRON PLUG VALVE 200 PSI, 2 - 1/2' AND LARGER SHALL BE IRON FLANGED, PLUG VALVE, 200 PSI. PAINT ALL GAS PIPING EXTERIOR TO THE BUILDING, WHICH WAS INSTALLED UNDER THIS CONTRACT, WITH TWO COATS OF DARK BROWN RUST RESISTANT PAINT. PIPE SHALL BE CLEANED PRIOR TO PAINTING. GAS PIPING ON ROOF SHALL BE INSTALLED AND SUPPORTED PER DETAILS. tl. THERE SHALL BE NO VALVES OR UNIONS INSTALLED IN RETURN AIR PLENUMS. BURIED UNDERGROUND AND BELOW FLOOR SEVER AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON PIPE WITH APPROVED COMPRESSION JOINTS. UNDERGROUND SEVER PIPING SHALL BE A MINIMUM SIZE OF 2', MINIMUM OF 1/8' PER FOOT OF SLOPE. NG- HUB JOINTS ARE NOT PERMITTED. 3n. UNDERGROUND SEVER PIPING AND FITTINGS MAY BE PVC -DVS ASTM- D2665 -78 SCHEDULE 40 WITH SOLVENT WELDED JOINTS. UNDERGROUND SEWER PIPING SHALL AA MINIMUM SIZE OF 2', MINIMUM OF 1/8' PER 'FOOT OF SLOPE. ABOVE GROUND, ABOVE OR BELOW FLOOR, SEVER AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON PIPE WITH NO HUB JOINTS. PVC AND ABS PIPING ARE NOT PERMITTED. UNDERGROUND AND BELOW FLOOR HOT AND COLD WATER PIPING SHALL BE TYPE 'K' COPPER PIPE OR TUBING WITH SIL -FOS 15 SILVER BRAZED JOINTS. ABOVE FLOOR HOT AND COLD WATER PIPING SHALL BE TYPE 'L' COPPER PIPE WITH 95 -5 SOLDERED JOINTS OR SIL -FOS 15 SILVER . BRAZED JOINTS. INSULATE ALL ABOVE GROUND, ABOVE DR BELOW FLOUR.. NO?. AND COLD WATER PIPING WITH A MINIMUM OF (' ;THICK FIBERGLASS 'PIPE .. INSULATION WITH A VAPOR BARRIER AND PLENUM RATED PRE - MOLDED. FITTING COVERS MR '.1'.', THICK CLOSED CELL PLENUM RATED INS 848 LATE' SANITARY TINES SERVING TENANT SPACE WHEN REQUIRED, TO PREVENT CONDENSATION RESULTING FROM TENANT'S OPERATION. ALL JOINTS SHALL BE AND' SEALED WITH VAPOR BARRIER.CEMENT; ALL INSULATION, VAPOR BARRIERS, PRE- MOLDED'FITTING COVERS, ETC, SHALL HAVE SURFACE BURNING CHARACTERISTICS NOT EXCEEDING A FLAME SPREAD RATING OF 25 AND A SMOKE DEVELOPED RATING OF 50. FURNISH :AND INSTALL DIELECTRIC UNIONS FOR DISSIMILAR PIPING MATERIALS, ALL BACKFLOV PREVENTIRS, VALVES, UNIONS,. BYPASS PIPING AND TESTING AS REQUIREDBY '.THE FIXTURE MANUFACTURER, BY THE LOCAL UTILITY AND CODES. PROVIDE ACCEPTABLE SUPPORTEN,,' DEVICES FOR ALL PIPING ALLOW FOR PIPE EXPANSION AND PREVENTION OF ELECTROLYSIS SUPPORTING DEVICES NOT PROTECTED WITH A SHOP PLATING /FINISH SHALL BE COATED WITH':A RUST INHIBITING PRIMER. SUPPORT 'PER'' SEISMIC 'RUMEN. FOR ZENE3. 10. 12 GAS METER GAS METER - PHASE I - NOT APPLICABLE GAS METER - '52' - PHASE II - FOOD COURT WHERE GAS IS REQUIRED BY TENANT'S APPROVED DESIGN, 'A Al NO XP T A INSTALL EXPENSE ❑ LANDLORD, A GAS METER COMPLETE L OTHER ACCESSORIES PER LOCAL UTILI TV VITH RE SHUT OFF VALVES, LOCATE AL UNIONS LOCATE METER AS DIRECTED BY LANDLORD AND UTILITY. COMPANY. ALL FOOD TENANTS AND ANY HIGH HAZARD TENANT SHALL FURNISH AND INSTALL A REDUCED PRESSURE BACKFLOV PRESENTER. WHERE REQUIRED BY LOCAL AUTHORITIES AND UTILITIES ALL TENANTS SHALL INSTALL BACKFLOW PREVENTION. CONNECT TO LANDLORD'S SANITARY AND COLD WATER PIPING AT LANDLORD'S POINT OF SERVICE CONNECTION. PHASE I AND FOOD COURT TENANTS SHALL CONNECT TO LANDLORD SUPPLIED SANITARY VENT SYSTEM. WHERE ADDITIONAL POINTS) OR INCREASED SIZE OF SERVICE IS REQUIRED (AND APPROVED BY LANDLORD) EMPLOY LANDLORD'S CONTRACTOR TO PERFORM THE WORK PER THE LANDLORD'S CRITERIA AT NO EXPENSE TO LANDLORD. SEE PLAN FOR LOCATION. ALL TENANT WORK PERFORMED ABOVE THE CEILING OF OTHER TENANTS SHALL BE L'OORDINATFD VITH OTHER TENANT(S) AND LANDLORD. AIR [HAMBERS ARE REQUIRED ON EA CH NOT AND COLD WATE SUPPLY TO EACH PLUMBING FIXTURE OR PROVIDE S SHOCK ABSORBERS S IMILAR TO J.R. SMITH 'HY DROTROL' SERIES 5000. SIZE AS REQUIRED BY TENANT PLUMBING SYSTEM PLUMBING FIXTURES - THE FOLLOWING IS A MINIMUM SPECIFICATION FOR FIXTURES. 1. INTERCEPTORS GREASE INTERCEPTOR SHALL BE INSTALLED WHERE REQUIRED BY STATE AND LOCAL CODES AND LANDLOR'D'S REQUIREMENTS TO RECEIVE GREASE LADEN WASTE. TENANTS SUBMITTAL DRAWINGS SHALL STATE INTERCEPTOR FLOW CAPACITY IN G.P.M. AND POUNDS OF GREASE STORAGE. FLOW CAPACITY AND POUNDS OF GREASE STORAGE SHALL BE CALCULATED PER THE GREASE TRAP MANUFACTURER'S GUIDELINES. CONT- RACTOR SHALL VENT ALL FIXTURES DRAINING TO GREASE TRAPS AND THE GREASE TRAP. GREASE INTERCEPTOR SHALL BE CAST IRON J.R. SMITH 8000 SERIES, COMPLETE VITH FLOW CONTROL. INSTALL IN LOCATION AND METHOD APPROVED BY LANDLORD AND THE LOCAL PLUMBING AND HEALTH DEPARTMENT CODES. WORK SINKS FOR HAIR SALONS, PET SHOPS. AND EYEGLASS LABORATORIES. INTERCEPTORS SHALL BE EQUAL TD J.R. SMITH 8700 SERIES. F00D PREPARATION PLUMBING FIXTURES SHALL BE STAINLESS STEEL ANO SHALL BE FURNISHED, INSTALLED ANO CONSTRUCTED TO CONFORM F O NDA CODES, HEALTH DEPARTMENT, AND NATIONAL SANITATION FOUNDATION WATER CLOSET,- AMERICAN STANDARD 2108. 408 CADET WITH CHROME SUPPLY AND STOP VALVE, AND OPEN FRONT WHITE SEAT AND SEAT' COVER. SET AT ADA HEIGHT LAVATORY'- AMERICAN STANDARD 9140. 011 WHEEL 'CHAIR LAVATORY 27 X 20' VITH WALL HANGERS,; CHROME SUPPLIES AND STOPS; AND 1-1/2' CHROME TRAP VITH CLEANOUT. FURNISH WITH CENTER :SET FAUCET, SELF CLOSING WITH FLOW. REGULATION. AMERICAN STANDARD'. OR EQUAL. CHROME PLATED WITH 7723.018 GRID DRAIN /OFFSET. TAIL HUECE. ', WATER HEATER' (MINIMUM) - A. O. SMITH - 6 GALLON, 1500 WATTS INSULATED PER'ENERGY CODE. T6P VALVE SHALL BE PIPED FULL: SIZE AND SAFEVASTED TO A DRAIN PAN OR FLOOR DRAIN HEATER SHALL HAVE A 5 WARRANTY. WATER HEATERS. SHALL CONFORM TO ALL ENERGY CODES AND SHALL INCORPORATE AR-GALLON THERMAL EXPANSION:TANK HEATER SHALL BE ELECTRIC OR GAS FIRED AND SHALL INCORPORATE A TEMPERATURE- PRESSURE RELIEF VALVE.PIPED TO IA FLOUR DRAIN., WHERE WATER HEATERS ARE INSTALLED ABOVE THE FINISHED CEILING, INSTALL HEATERS,. A 3'. DEEP WATER TIGHT PAN WITH RELIEF VALVE PIPED TO PAN AND PAN SAFE WASTED TO AN' APPROVED FLOOR DRAIN. GAS ',FIRED WATER HEATERS SHALL NOT BE INSTALLED.' IN CONCEALED SPACES AND SHALL BE LOCATED IN F' SEPARATE ROOM.' PROVIDE COMBUSTION AIR FOR GAS FIRED WATER HEATERS V... A ZERO TO POSITIVE PRESSURE ENVIRONMENT. INSTANTANEOUS UNDERSINK TYPE WATER HEATERS ARE ALSO ACCEPTABLE HAND SINKS, FAUCETS AND SPECIALTIES,SHALL BE FURNISHED AND INSTALLED PER HEALTH DEPARTMENT REQUIREMENTS AND ALL APPLICABLE CODES. FLOOR BRAIN'- J.R. SMITH .FIGURE 2010 - VITH A NICKEL :. BRONZE OR SATIN BRONZE FINISH WITH PRIMER TAPPING WHEN REQUIRED: FLOOR DRAINS SERVING ALL SODA DISPENSER', WASTE LINES SHALL BE PROVIDED WITH TRAP PRIMERS 10. CLEANOUTS - J. R. SMITH 4000 SERIES VITH NICKEL BRONZE OR SATIN BRONZE FINISH TOP AND TAPER THREAD BRONZE PLUG OF SIZES SHOWN ON PLANS. ALL CLEANOUTS SHALL BE INSTALLED IN FINISHED FLOUR OR .ABOVE. CLEANOUTS UNDER SLAB ARE NOT ACCEPTABLE. I1. TRAP SEAL PRIMER. VALVE - J. R. SMITH FIGURE 2699.. 12. WATER, METER FIRE SUPPRESSION SYSTEMS PHASE I. G21 AND FOOD COURT INSTALL Ai NO EXPENSE TO LANDLORD,A WATER METER IN AN APPROVED LOCATION PER THE LOCALWATER UTILITY COMPANY AND LANDLORD'S" REQUIREMENTS. CONTRACTOR SHALL PAY ALL FEES AND LANDLORD CHARGES ASSOCIATED WITH METER AND METER INSTALLATION. PHASE 'll - WATER SUB METER IS REQUIRED ONL" LARGE WATER CONSUMING TENANTS WATER'. METER TO BE INSTALLED BY TENANT COMPLETE WITH UNIONS AND SERVICE VALVES. 'TENANT i0 PURCHASE AND 'INSTALL BADGER MODEL SC ER OR APPROVED EQUAL, .DIGITAL READ OUT IN CU. FT. LOCATE METER 4' -6' AM IN AREADILY ACCESSIBLE LOCATION. A. TENANT'S SPRINKLER SYSTEM SHALL BE INSTALLED FROM LANDLORD'S SPRINKLER BULKIMAIN SERVILE PROVIDED BY LANDLORD. FOR THE PREMISES IN THE EVENT A' SYSTEM EXISTS, MODIFY THE EXISTING SYSTEM. IN THE 'EVENT. TENANT REQUIRES LARGER SPRINKLER. SERVICE, TENANTS CONTRACTOR SHALL EMPLOY LANDLORD'S CONTRACTOR TO INSTALL INCREASED SHEAF SERVICE, PER LANDLORD REQUIREMENTS. THERE .SHALL BE ONLY ONE CONNECTION PER TENANT THERE. SHALL BE NO CROSS FEEDS TO OTHER TENANTS OR MALL SYSTEMS PROVIDE A SPRINKLER SYSTEM FOR THE ENTIRE PREMISE S.. INCLUDING ALL PIPING AND ACCESSORIES PER THE REQUIREMENTS OF ALL APPLICABLE CODES, FACTORYIMUTUAL, NFPA -13, LANDLORD AND LANDLORD'S FIREAND CASUALTY INSURER: ALL PIPING SHALL BE HYDRAULICALLY DESIGNED AND INSTALLED PER NFPA -I3 ORDINARY HAZARD, CLASSIFICATION 'GROUP II. HYDRAULIC, CRITERIA FUR SYSTEM DESIGN SHALL DE., DENSITY'- O.18 GPM PER SO. FT. - FIRE AREA - MOST REMOTE 25000 SQ. FT. WITH A 500 GPM'.HOSE ALLOWANCE. OBTAIN FLOW AND PRESSURE 'FROM LOCAL !AUTHORITIES OR LANDLORD'S INSURANCE UNDERWRITER PIPING SHALL .BE PER NFPA,, OR IF MORE STRINGENT FM APPROVED • MAXIMUM SPACING OF SPRINKLER HEADS SHALL BE 130 SQ. , PER HEAD IN SALES AREA AND 100 SO. FT. PER HEAD IN STORAGE AREAS OR HIGH HAZARD AREAS. SPRINKLER HEADS IN THE SALES AREA SHALL BECONCEALED /FLUSH OR. SEMI - RECESSED PENDANT VITH.. AN ESCUTCHEON. SPRINKLER'HEADS IN STOCK ROOM SHALL BE RECESSED OR .UPRIGHT, BRASS'. OR CHROME.. HEADS IN CONTROL AREA (STOREFRONT POP -OUT) SHALL BE:.CONCEAIED /FLUSH TYPE, FACTORY PAINTED TO MATCH CEILING COLOR. TEMPERATURE RATINGS SHALL BE AS ,REQUIRED BY LANDLORD'S. FIRE AND CASUALTY INSURER AND/OR AUTHORITY.HAVING 'JURISDICTION. ALL !SPRINKLER .HEADS MUST BE UNDERWRITER'S LABORATORIES'LISTED AND FACTORY MHUAL APPROVED.: CONTRACTOR SHALL OBTAIN FROM LANDLORD THE LANDLORD'S FIRE AND CASUALTY INSURERS NAME, ADDRESS, AND'PROJECT INDEX NUMBER. PRIOR TO INSTALLATION, CONTRACTOR SHALL SUBMIT. SEVEN (7).SETS OF I . CALCULATIONS AND SEVEN Y7) SETS OF PRINTS OF SPRINKLER DESIGN TO LANDLORD'S FIRE AND CASUALTYIENSURER FOR. APPROVAL. UPON APPROVAL AND PRICIR TO INSTALLATION, CONTRACTOR , ,SHALL FORWARD ONE (1) REPRODUCIBLE SEPIA MIT. APPROVED, AND TWO (2) BLUE LINE PRINTS. WHICH SHALL HAVE THEILANDLORD' APPROVAL STAMP' TO THE LANDLORD FOR LANDLORD'5 APPROVALAND RECORDS.. CONTRACTOR: TO OBTAIN ALL OTHER' APPROVALS FROM APPLICABLE AUTHORITIES AND SUBMIT APPROVED PRINTS TO LANDLORD FOR LANDLORD'S RECORDS • 1 G REIMBURSE LANDLORD FUR ALL COSTS OF DRAINING AND REFILLING LANDLORD'S SPRINKLER SYSTEM WHERE SAME IS REQUIRED TO COMPLETE TENANT'S SPRINKLER SYSTEM. H. IV. HVAC ALL OTHER CODE OR LANDLORD REQUIRED FIRE PREVENTION SYSTEMS AND ACCESSORIES SHALL BE INCORPORATED AS PART OF THIS SCOPE OF WORK. TENANT'S SPRINKLER PIPING 4' AND LARGER SHALL BE INSTALLED VITH HANGERS AT EVERY BAR JOIST WHEN INSTALLED PERPENDICULAR TO BAR JOISTS, AND VITH HANGERS SUPPORTED FROM TWO BAR JOISTS EVERY 10' -0' UN CENTERS WHEN INSTALLED PARALLEL TO BAR JOISTS. ALL HANGERS AND /OR SUPPORTS SHALL BE INSTALLED VIM. 6' OF A JOIST PANEL POINT. THE MALL MANAGEMENT, THE LANDLORD'S FIRE AND CASUALTY INSURER, AND THE LOCAL FIRE DEPARTMENT MUST BE NOTIFIED AT LEAST 48 HOURS PRIOR TO MAKING ANY MODIFICATIONS TO THE EXISTING FIRE PROTECTION SYSTEMS, WORK SHALL BE COORDINATED SO THAT ONLY ONE <1) RISER OR BULKMAIN IS SHUT -DOWN FOR ANY GIVEN TIME. SPRINKLER SYSTEH(S) SERVICE SHALL BE RESTORED TO THE AREAS AFFECTED AT THE END OF EACH WORKING DAY DURING THE CONSTRUCTION PERIOD. PIPING TEST - ALL ABOVE GRADE PIPING INSTALLED BY THIS CONTRACTOR SHALL BE TESTED AT A PRESSURE OF 200 CBS. HYDROSTATIC FOR TWO (2) HOURS AND ALL NOTICEABLE LEAKS TO BE REPAIRED UNTIL TIGHT TEST SHALL BE WITNESSED BY THE OWNER'S REPRESENTATIVE AND WRITTEN CERTIFICATION OF SUCCESSFUL TESTING SHALL BE SUBMITTED TO THE ENGINEER PRIOR TO FINAL ACCEPTANCE. THIS CONTRACTOR SHALL ALSO BE REQUIRED TO PERFORM ALL OTHER TESTS REQUIRED BY THE PREVIOUS SPECIFIED AGENCY HAVING AUTHORITY. EXHAUST HOODS WHERE REQUIRED BY CODES AND /OR LANDLORD'S PROPERTY AND CASUALTY INSURER S, SHALL INCORPORATE AN APPROVED AUTOMATIC FIRE SUPPRESSION SYSTEMS COMPLETE WITH FAN INTERLOCK. AUTOMATIC GAS APPLIANCE SHUT -OFF SOLENOID VALVE, ELECTRICAL INTERLOCK(SHUNT TRIPS), MANUAL RELEASES, ETC., PER APPLICABLE CODES, NFPA,AND /OR LANDLORD'S FIRE AND CASUALTY INSURER(S. TOY STORES AND OTHER STORES THAT HAVE HIGH PILED STORAGE OF PLASTIC MATERIAL AS DETERMINED BY THE LOCAL FIRE MARSHALL AND /OR LANDLORD'S FIRE AND CASUALTY INSURER SHALL BE DESIGNED FOR 3 GPM PER S0. FT. OVER THE MOST REMOTE 3000 SQ. FT. VERIFY REQUIREMENTS. ' TENANT HVAC SYSTEM CRITERIA 1. TENANT SHALL DESIGN, FURNISH AND INSTALL A COMPLETE HVAC SYSTEM TO HEAT AND COOL THE ENTIRE PREMISES IN STRICT CONFORMANCE WITH THE CRITERIA AND DESCRIPTION CONTAINED ON LANDLORD'S MEC ANICAL DETAIL AND SPECIFICATION DRAWINGS, THE LEASE AND /OR TENANT MANUAL.' THE HEATING AND COOLING SYSTEM DESIGN SHALL BE BASED ON THE APPLICABLE STATE AND LOCAL CODE(S) AND THE INFORMATION PROVIDED ON THE ATTACHED CALCULATION FORM, WHICH' IS DERIVED FROM THE MOST. RECENT DESIGN CONDITIONS LISTED 1N THE AMERICAN SOCIETY OF HEATING. REFRIGERATION' AIR-CONDITIONING ENGINEERS, '.(A. S. H. R. A E > MANUAL HEAT GAIN CALCULATIONS SHALL BE BASED UPON THE`MONTH, DAY. AND HOUR UFIPEAK SOLAR, THERMAL AND INTERNAL HEA, GAINS USING CODE REQUIRED MINIMUM OUTSIDE AIR QUANTITIES AT DESIGN CONDITIONS: A T T UPON 7H I I A A IONS SHALL BE BASED U E FULL HE HEAT LOSS C LCUL L LOSS AND CODE .REQUIREDIMI N IMAM NOT O DE AIR O IN DESIGN CONDIT IONS,(CREOIT SHALL NOT BE TAKEN FOR INTERNAL HEAT GAINS) I 5. THE FOLLOWING SHALL BE 'APPLICABLE TO ITHEI CALCULATIONS' FOR SPECIAL OCCUPANCIES IC G., BEAUTY SALONS', PET SHOPS, BARBER SHOP,HGAME OR AMUSEMENT FACILITIES PHOTOFINISHING ESTABLISHMENTS, RESTAURANTS, ETC.): .ODE REQUIRED OCCUPANCY LEVEL. ' ICODE REQUIRED OUTSIDE AIR''OUANTI T IES. , HEAT PRODUCING. GAS UR' ELECTRIC APPLIANCE LOADS WITH LANDLORD APPROVED DIVERSITY' FACTORS T d .LANDLORD HAKE. -UP AIR REQU'I REMEN S. ALL MAKEUP A IR r. MUST BE CONDITIONED 'FOOD TYPE OR OTHER,ODOR PRODUCING TENANT'S HVAC SYSTEM SHALL. MAINTAIN'A SLIGHT NEGATIVE PRESSURE. DIFFERENTIAL BETWEEN:THE PREMISES AND THE ENCLOSED MALL AND OTHER COMMON AREAS OF ;THE SHOPPING CENTER NON ODOR. PROIXUCING ,TENANT'S HVAC SYSTEM SHALL MAINTAIN 'A SLIGHT POSITIVE PRESSURE DIFFERENTIAL BETWEEN THE PREMISES AND THE ENCLOSED MALL AND OTHER, COMMON AREAS OF THE SHOPPING CENTER R S AIR, EXHAUST, H USE PERMITTED BY LANOLQRD,. OUT [ DE AI R EL1Er AIR NOT BEPE .R OR ANY OTHER PENING OR GRILLE SHALL NOT BE PERMITTED IN OR ON ANY ANY D DEMISING PARTITION, SERVICE CORRIDOR .WALL OR EXTERIOR VALE OF ',THE PREMISES OR EXTERIOR WALL OF THE SHOPPING CENTER. TENANT HVAC SYSTEM PHASE II, G2 AND FOOD COURT - WHERE A HVAC UNIT S ISTO'BE REPLACED OR, WHERE A NEW INSTALLATION IS REQUIRED BY TENANTS, THE HVAC SYSTEM SHALL BE FURNISHED AND INSTALLED CONSISTING,OF. A GAS OR ELEC HEATING /ELECTRIC COOLING ROOFTOP UNIT(IS) TO SERVE THE ENTIRE PREMISES. EQUIPMENT SHALL BE EQUAL TO CARRIER, .TRANS, IOR YORK. PHASE II,TENANTS SHALL CONNECT TO LANDLORD'S TOILET EXHAUST DUCT PHASE A TENANTS SHALL INSTALL A SPLIT SYSTEM AIR CONDITIONER, -WI.TH ELECTRIC DUCT HEAT, ILOCATEDIIN AREAS DESIGNATED ON LANDLORD ➢RAVING. 'THE UNIT SHALL, BE TO THE LANDLORD'S MINIMUM OUTDOOR AIR DUCT WHERE PROVIDED THE'' AIR HANDLING 'UNIT SHALL BE MODULAR, FACTORY ASSEMBLED. DRAW THRUAN➢ SUPPORTED FROM STRUCTURCONLYNN AREAS APPROVED By LANDLORD AND PER LANDLORD DETAILS: THE1 CONDENSER UNIT SHALL ' BE:ROOF MOUNTED AND SUPPORTED BY,CURB Ai. LANDLORD'S DESIGNATED LOCATION REFRIGERANT PIPING SHALL BE ", ROUTED THROUGH LANDLORD DESIGNATED CHASES AND DOCUMENTED IN DESIGN DRAWINGS: CONDENSATE' SHALL IBE RUN i0 L L PROVIDE CONDENSATE DRAIN IN CORRIDOR,', WHEN PROVIDED; OR TO TENANTS SANITARY SEVER OR PUMPED TO,L. L. APPROVED SEVER TENANT SHALL ROUTE AS APPROVED BY L L : PHASE I FOOD COURT FOOD TENANTS AND ODOR PRODUCING TENANTS LOW AMBIENT CONTROL OF MECHANICAL COOLING DOWN TO 0 DEGREES F. AMBIENT TEMPERATURE IS REQUIRED ON ALL FOOD, FOOD COURT OR ODOR PRODUCING TENANT, ROOFTOP HVAC SYSTEMS AND ALL PHASE, SPLIT ,SYSTEMS. R.I.P. EXHAUST IS REQUIRED FOR .FOOD AND 'ODOR PRODUCING TENANTS PHASE 11 NON FOOD TENANTS LOW AMBIENT CONTROL ,OR ECONOMIZER CYCLE IS REQUIRED ON ALL PHASE 411 NON ODOR PRODUCING TENANTS: IF AN ECONOMIZER CYCLE.IS ANCORPORATED, HVAC SYSTEM SHALL- INCORPORATE A GRAVITY OR .INTEGRAL POWERED RELIEF IN THE ROOFTOP UNIT. PHASE II, G2 AND FOOD COURT SUPPORT RTUs ON FUEL' PERIMETER CURB AS SUPPLIED BY THE UNIT: MANUFACTURER ONLY IN AREAS STRUCTURALLY AND AESTHETICALLY '',APPROVED BY LANDLORD DETAILS 'C X 6 7 LBS /FT STRUCTURAL STEEL CHANNEL SUPPORTS TO SPAN JOISTS UNDER RTU CURB.. ALL TENANT ROOF , EQUIPMENT SHALL BE LOCATED AT A'MINIMUM OF FIFTEEN (15) FEET FROM ANY MALL EQUIPMENT, AND FROM ANY OTHER TENANT'S ROOF EQUIPMENT. .NOTIFY LANDLORD'S ENGINEER OF ANY CONFLICTS. OBTAIN LANDLORD FIELD REPRESENTATIVE'S WRITTEN APPROVAL BEFORE CUTTING ROOF. GOOSENECKS SHALL NOT BE INSTALLED UNLESS. SPECIFICALLY APPROVED BY LANDLORD TEMPORARY WORK PLATFORM (MIN "4' 0' VIDE) IS REQUIRED. CONSISTING: OF PLYWOOD COMPLETELY. SURROUNDING THE ROOFTOP UNITS AND OTHER :. EQUIPMENT ORI DUCTS THROUGH THE ROOF, THE ENTIRE VORKT. AREA SHALL I REMAINON ROOF: DURING THE ENTIRE PERIOD OF INSTALLATION AND SHALL BE REMOVED FROM THE ROOF .'THE SHOPPING CENTER SITE UPON COMPLETION OF THE INSTALLATION BY CONTRACTOR, ALL ROOF MOUNTED FANS. TOILET , EXHAUETERS. AND IMISEELL EQUIPMENT SHALL;BE OF ALUMINUM CONSTRUCTION, VITH. FABRICATED ROOF. CURB PEC AS IFICATION DET l,,, ON ➢RAVINGS : LANDLURD'IS , TYPICAL TENANT'S DETAIL A 0 SS N I ROUTE, ELECTRIC RORER AND CONTROL VIRING:THROUGH A SEP RILOF.'i PENETRATION FUR. EACH F, THE CONDUITS .PLASH PENETRATION PER LANDLORD DETAILS. IDO NOT ROUTE POWER CONDUIT,. THROUGH ROOF CURB.'., WALL 'DO NOT DRILL HOLES IN CONDENSATE PAN OR COMPRESSOR /CONDENS R E SECTION FLOOR ALL TENANT ROOF MOUNTED EQUIPMENT SHALL BE IDENTIFIED WITH A LANDLORD SUPPLIED LABEL. THE TENANT SHALL CONTACT THE MALL MANAGEMENT FOR THE NECESSARY LABEL. IF THE LANDLORD'S LABEL IS NOT AVAILABLE THE ROOF TIP EQUIPMENT SHALL BE MARKED WITH THE TENANT'S NAME AND UNIT NUMBER VITH A MINIMUM OF I -1/2' STENCILED LETTERS. FRAME ALL SIDES OF ROOF PENETRATIONS, IF ONE SIDE OF PENETRATION IS GREATER THAN 12 INCHES, WITH 3' X 3' X 1/4' ANGLE TO SUPPORT THE METAL DECK ANGLES SHALL BE CLAMPED OR WELDED TO THE STRUCTURAL STEEL JOISTS, BEAMS, OR GIRDERS AND SHALL BE INSTALLED i.GHT TO THE BOTTOM OF THE ROOF DECK. INSTALLATION SHALL BE AS APPROVED BY THE LANDLORD. DO NOT DRILL JOISTS, L. ROOF MOUNTED EQUIPMENT PROJECTIONS NONE OF TENANT'S HVAC EQUIPMENT OR ANY OTHER TENANT ROOF MOUNTED CONSTRUCTION SHALL BE VISIBLE ABOVE THE EXTERIOR WALL PARAPET, UNLESS OTHERWISE PERMITTED BY LANDLORD. IF PERMITTED, TENANT SHALL, AT TENANT'S EXPENSE, PAINT ALL SUCH HVAC EQUIPMENT OR ROOF MOUNTED CONSTRUCTION AND /OR PROVIDE SCREENING FOR SAME AS KAY BE REQUIRED BY LANDLORD. DIFFUSERS, GRILLES, AND REGISTERS SHALL BE STEEL OR ALUMINUM AS MANUFACTURED BY TITUS. BARBER- COLMMN, CARNES, OR OTHER APPROVED WITH OPPOSED BLADE DAMPERS. RETURN AIR BETWEEN STOCK AND SALES AREA SHALL NOT RELY UPON ANY ACCESS WAY (DOORWAYS, WINDOW OPENINGS, ETC.) BETWEEN STOCK AND SALES AREAS. N. AIR BALANCE ALL EQUIPMENT, INCLUDING ROOFTOP UNITS, DIFFUSERS, REGISTERS. AND GRILLES TO THE AIR QUANTITIES INDICATED ON THE PLANS OR ON THE SCHEDULE TO WITHIN 107. OF VALUES. O. FLEXIBLE CONNECTORS WHICH ARE CODE APPROVED ARE REQUIRED ON ALL DUCTWORK CONNECTIONS TO AIR MOVING EQUIPMENT INCLUDING ROOFTOP AIR HANDLING UNIT. , AND FMCS). . FIRE DAMPERS ARE REQUIRED TO BE INSTALLED IN ANY OPENING IN ANY PARTITION WHERE THE OPENING OCCURS BELOW THE LEVEL OF THE SPRINKLER PROTECTION ON ONE SIDE OF THE PARTITION AND ABOVE THE SPRINKLER PROTECTION ON THE OTHER SIDE OF THE PARTITION, AND PENETRATIONS OF FIRE RATED CONSTRUCTION PER CODE. FIRE DAMPERS SHALL BE u. L. LISTED AND INSTALLED PER MANUFACTURERS REQUIREMENTS. FIRE DAMPERS SHALL BE RUSKIN, AIR BALANCE, OR OTHER LANDLORD APPROVED bLL NON -HOODED DUCT, RK FITTINGS, HANGERS, FABRICA)IONS, INSTALLATIONS, MATERIALS AND METHODS SHALL BE GALVANIZED SHEET METAL FABRICATED AND INSTALLED IN STRICT ACCORDANCE WITH THE LATEST EDITION CF SMACNA, NFPA, ALL CODES AND AS DETAILED ON DRAWINGS. UNLESS OTHERWISE NOTED, SUPPLY. RETURN, AND EXHAUST DUCTVURK SHALL BE CONSTRUCTED IN CONFORMANCE WITH THE 1' V. G. POSITIVE /NEGATIVE PRESSURE TABLE. ALL DUCTWORK SHALL BE INSTALLED AS HIGH AS POSSIBLE. R. INSULATE ALL SUPPLY AIR, OUTSIDE AIR, AND COMBUSTION AIR DUCTWORK VITH 1-12' THICK EXTERIOR FIBERGLASS DUCT INSULATION WITH VAPOR BARRIER PER MANUFACTURERS REQUIREMENTS AND RECOMMENDATIONS. IF CONDENSATE FORMS ON ANY MALL OR TENANT SURFACE, INSULATE AS REQUIRED TO ELIMINATE THE CONDENSATION FLEXIBLE, DUCTWORK SHALL ONLY BE PERMITTED TD BE INSTALLED' FOR THE FINAL VERTICAL CONNECTION TO DIFFUSERS: THE MAXIMUM LENGTH OF FLEXIBLE'. DUCT SHALL BE : LIMITED TO 5' -0' FOR ANY UNE DIFFUSER ICONNECTT@N FLEXIBLE DUCT MATERIAL SHALL HAVE A FLAME SPREAD LESS THAN 25 AND A SMOKE DEVELOPED RATING LESS THAN 50 SECUREBOTH ENDS. WITH APPROVED PLENUM MATERIAL U. DUCTED RE TUR [ R SY N 4 ,EMS ISHpLL'ONt:Y BE INSTALLED, WHEN REQUIRED OR S APPROV LANDLORD WHEN DUCTED RETURN A RELIEF RII (OR PERMITTTT ED) BY LANDLORD. FURNISH AND INSTALL L RELIEF F GRILLES LLES IN IN CEILING 300 TO PREVENT 300 SQ SQ FREEZING RELIEF GRILLES SHALL BE SIZED ,AT I. SQ- FT: PER I FT. :LEASABLE AREA. BOOTED RETURN AIR SYSTEM. GRILLES SHALL BE SIZED FOR A MAXIMUM OF 50,0 F. P. M, VELOCITY: SEAL DUCT PENETRATIONS AT DEMISING WALLS WITH MATERIAL APPROVED BY APPLICABLE CODE AuTFORITTES- W. TENANTS WHICH, IN, THE SOLE OPINION, OF THE LANDLORD, PRUDUCE'.ODOR SHALL PROVIDE AN EXHAUST SYSTEM AND /OR OTHER SYSTEMS; WHICHWEL PREVENT SUCH ODORS FROM ENTERING THE, MALL COMMON AREA OR OTHER. TENANT' SPACES A T F THE UP D X.' F TENANT'S ALLN EV HVAC CONTRACUNI TS. NUS, :PRIOR TO OPENING THE ACTION OR E S F ALL N: UNITS. '''PR UDR TO ENING WRITTEN VERIFICATION BUSINESS CONTRACTOR. SHALL PROVIDE LANDLORD VITH WRITTEN VERIFICA CAT i1 ONFROM:AN AUTHORIZED REPRESENTATIVE OF THE INSTALLED HVAC, EQUIPMENT, MANUFACTURER THAT THE HVAC EQUIPMENT IS INSTALLED. AND OPERATING IN ACCORDANCE VITH THE EQUIPMENT MANUFACTURER'S REQUIREMENTS.', IN THE I EVENT. THE LANDLORD DETERMINES TENANT'S. HVAC EQUIPMENT IS NOT OPERATING IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'SI RECOMMENDATIONS, LANDLORD'S FIELD. REPRESENTATIVE SHALL WITHIN FIVE (5) DAYS FROM LANDLORD'S' WRITTEN NOTICE TO TENANT OR IOINANT'S. CONTRACTOR OF SAME, CORRECT SUCH OPERATIONAL DEFICIENCY: EXHAUST FANS WHERE APPROVED FOR INSTALLATION BY THE LANDLORD, FIBERGLASS DUCTWORK SHALL BE 1 -1/2' OVENS /CORNING TYPE 800 FRK INSTALLED PER THE MANUFACTURER'S AND SMACNA'S REQUIREMENTS FOR SUPPLY AND RETURN AIR DUCT., EACH TOILET ROOM SHALL HAVE 'A TOILET EXHAUST FAN, CONTROLLED gY A LIGHT SWITCH, SIZED PER CODE AND RATED AT MINIMUM 25'EXIERNAL STATIC PRESSURE. TOILET EXHAUST FAN SHALL BE CONNECTED TO LANDLORD'S TOILET EXHAUST DUCT TOILET EXHAUST FANS SHALL BE CEILING MOUNTED WITH INTEGRAL GRILLES, AND BACKDRAFT DAMPER. FAN SHALL BE PENN, GREENHECK, NUTONE OR OTHER APPROVED ROOF MOUNTED GREASE EXHAUST FANS SHALL BE BELT DRIVEN, T APPROVED F LL E O FOR GREASE LADEN AIR UPB LAST CENTRIFUGAL MOTORS SHALL BE .INSTALLED OUT OF THE AIRISTREAM; COMPLETE VITH EL CU M E E TI NG '.FANS SHALL EQUI REQUIREMENTS. NHECK O ' . MODEL CUBE, MEETING NFPA 96REQU IREMENTS ALL TO HAVE '. GREASE GUARD INSTALLEIf SEE DETAIL ALL FANSIREQUIRED,:FOR RELIEF, MAKE -UP AIR OR EXHAUST (EXCEPT TOILET Room, SHALL BE ANIUPBLAST ROOF MOUNTED AND OF: A CENTRIFUGAL TYPE WITH A BELT, OR DIRECT DRIVEN ENCLOSED MOTOR OUTSIDE THE AIR ',STREAM CLASS B TYPE MOTORS SHALL BE USED FOR HIGFII TEMPERATURE APPLICATIONS FALL ROOF MOUNTEDFANS SHALL INCORPORATE 'A COUNTERBALANCED BACK DRAFT DAMPER OR A MOTOR OPERATED DAMPER INTERLOCKED VITH FAN OPERATION AND A SERVICE DISCONNECT SWITCH AT THE FAN. PHASE ]I, G2, AND FOODCOURT SHALL INSTALL A SMOKE RELIEF FAN! WITH MOTRIZEIS' DAMP ER. THE FAN CAPAGIL_E TYESLL 0.25 H BE INC 1'AND UNE HALF CFM PER: QUARE FOT OF LEASEAB AREA HA qT W C HOODED EXHAUST SYSTEMS HOODS, .DUCTWORK AND ACCESSORIES SHALL BE::SIZEIN CONSTRUCTED AND INSTALLED 'PER NFPA 196 AND , ALL STATE AND LOCAL CODES, AND LANDLORD'S INSURANCE UNDERWRITERS HOODS SHALL BE U..L LISTED. DUCTVURK AND HOOD MATERIAL SHALL B S SEEDED 16 GAUGEST 18 GAUGE STAINLESS STEEL BR AS OTHERWISE! REQUIRED BY CODES. STAINLESS STEEL' CONSTRUCTION SHALL BE USED BELOW FINISHED CEILING UNLESS OTHERWISE APPROVED BY LANDLORD. REPRESENTATIVE. ALL SEAMS AND JOINTS SHALL HAVE LIQUID.TIGHT CONTINUOUS '.. EXTERNAL WELDS. DUCTS SHALL BE INSTALLED WITHOUT FORMING DRIPS AND TRAPS WHICH MIGHT COLLECT RESIDUES. SLOPE DUCT TOWARD : HOOD. ALL'. HOOD EXHAUST DUCTS SHALL BE :INSULATED WITH HIGH TEMPERATURE INSULATION. THE AIR VELOCITY THROUGH ANY. DUCT SHALL NU7 BE LESS THAN 1500. FEET. PER MINUTE. NUR .GREATER' THAN 2200 FEET;. PER MINUTE, ACCESS DOORS SHALL BE GASKETED AND PROVIDED FOR INSPECTION AND O EANING AND SHALL BE INSTALLED AT EACH CHANGE OF DIRELifON. GREASE LADEN AIR. SHALL BE 'DISCHARGED VERTICALLY.. ABOVE ROOF AT CODE REQUIRED HEIGHT. TENANT'S CONTRACTOR SHALL FURNISH. AND INSTALL A 'GREASE GUARD' SYSTEM FUFA GREASE A T. U 6-800 - 288-82 HALL . 'GREASE GUARD' , S BE AS MANIIFACTURED 'GREGREASE SE GUARD' (1 800. - 284-8273) MAINTAIN MINIMUMCLEARANCES'BETWEEN DUCT,'': AND OTHER STRUCTURES AS REQUIRED BY CO ➢E. I SULATE 880 /0R.ENC ASE DUC:T,ABO8 CEILINGS 1NSTALL AS N , REQUIRED BY .CODE AN➢ PROVIDE CLEARANCES. FROM COMBJSTI BEES I AS I , REQUIRED BY CODE , AS' 'FLUES SHALL - .BE TYPE B OR, IF MORE STRINGENT '.REQUIRED BY CODE. E. INSTALL INSTALL IN A (,.HOUR FIRE. RATED SHAFT. NUN 'COMBUSTIBLE iEO WITH FI E R CONSTRUCTION, I IN SUL t CTION, WITH CODE.. REQUIRED CLEARANCES AND '.. RATED AT ON' UP RODE NO ,FIRE D AMPER DAMPER ,SHALL!, BE INSTALLEED TIN H000 EXHAUST AB. FIRE DETECTION AND SMOKE CONTROL SYSTEM THE HVAC SYSTEM SHALL INCORPORATE AN INTEGRATED SMOKE CONTROL SYSTEM AS FOLLOWS PHASE PHASE II - FURNISH AND INSTALL, IN THE SUPPLY DUCT SECTION OF THE ROOFTOP UNIT OR AIR HANDLER, U. L. LISTED IONIZATION DUCT TYPE SMOKE DETECTORS. LOCATE SMOKE DETECTORS IN AN ACCESSIBLE LOCATION, COMPLETE WITH DISCONNECT SWITCH FOR SERVICING AND RESETTING OF THE SMOKE DETECTOR WITH INDICATOR LIGHTS. A. SMOKE DETECTOR, UPON ACTIVATION, SHALL SHUT DOWN THE HVAC SYSTEM AND NOTIFY AN APPROVED CENTRAL STATION MONITORING COMPANY. CONSULT CITY OF TUKWILA FOR A LIST Of U. L. LISTED AND APPROVED CENTRAL STATION MONITORS. A. TENANT SHALL INSTALL AN ADDITIONAL SMOKE DETECTOR AT THE STORE FRONT AND ADDITIONAL SMOKE DETECTORS FOR EACH 30' OF OPEN STORE FRONT. THE SMOKE DETECTOR, UPON ACTIVATION, SHALL SHUTDOWN THE HVAC SYSTEM, NOTIFY LANDLORD'S FIRE DETECTION AND SMOKE CONTROL SYSYTEM AND ACTIVATE A SEPARATE ROOF MOUNTED SMOKE RELIEF FAN FURNISHED WITH A MOTORIZED DAMPER AND INSTALLED ON A FABRICATED CURB PER DETAIL. THE SYSTEM SHALL ACTIVATE AN AUDIBLE /VISUAL ALARM AT THE FRONT OF THE STORE UPON ACTIVATION. MINIMUM CFM CAPACITY OF ROOF MOUNTED SMOKE RELIEF FAN SHALL BE ONE AND ONE HALF CFM PER SQUARE FOOT OF GROSS LEASABLE AREA AT 0.25 INCH WATER COLUMN STATIC PRESSURE. PROVIDE ALL ADDITIONAL CONTROLS REQUIRED TO PERMIT THE SEQUENCE DESCRIBED ABOVE, INCLUDING CLOSING OF THE OUTDOOR AIR DAMPER IN THE HVAC UNIT. FOOD COURT AND G2 THE SMOKE DETECTOR S /1AL', UPON ACTIVATION, SHUT DOWN THE HVAC SYSTEM, SOUND AN ALIDIU/VISUAL ALARM HORN L OCAIED Ai TH[ FRONT Of 7NF S70RE. AS PHASE II. ITEMS b,c and tl AND AS PHASE I. 5. PROVIDE ALL ADDITIONAL CONTROLS REQUIRED TO PERMIT THE SEQUENCE. DESCRIBED ABOVE. AC TEMPERATURE CONTROLS. WIRING AND MISCELLANEOUS REQUIREMENTS 1. ALL CONTROLS SHALL BE A PNEUMATIC. CONNECT TO LANDLORD'S CENTRAL PNEUMATIC AIR SYSTEM. ALL OTHER CONTROLS SHALL BE A MAXIMUM OF 24 VOLTS. ALL CONTROL WIRING SHALL BE INSTALLED IN STRICT ACCORDANCE WITH NATIONAL'. ELECTRICAL CODE. ALL EXHAUST FANS (EXCEPT TOILET EXHAUST FAN) SHALL INCORPORATE STARTERS.', 'ALL EXISTING AND NEV :MIRING IN PLENUM AREAS .SHALL BE , MODIFIED AND /OR INSTALLED IN CONDUIT OR BE CABLE LISTED FOR I USE IN,PLENUM AREAS ',:FIELD VERIFY ALL EXISTING' WIRING TO DETERMINE THE EXTENT OF THE REQUIRED MODIFICATION: CONTROL R WIRING FOR HVAC CONTROL SHALL BE MULTICOLORED CABLE. (87 - 16 AVG WITH 600V: JACKET INSULATION: THERMOSTATS FOR TEMPERATURE CONTROL SHALL BE OF THE PNEUMATIC .TYPE, REVERSE ACTING, OR OTHER LANDLORD APPROVED. MODIFY INSTALLATION OF' ALL EXISTING CONTROLS AS REQUIRED BY LANDLORD FOR PROPER OPERATION OF THE HVAC SYSTEMS. CONTRACTOR TO FURNISH 1 AS BUILT' DRAWINGS OF THE TEMPERATURE CONTROL SYSTEM INCLUDING:ALL HVAC EQUIPMENT CONTROL DIAGRAMS 'AS SUPPLIED BY THE EQUIPMENT MANUFACTURER AND ALL FIELD INSTALLED WIRING AND CONTROLS. D. TENANT INSTALL ROOF TREAD': PADS AROUND ALL ROOF MOUNTED EQUIPMENT AND TU LANDLORD'S MAIN TRAFFIC AISLE. CONSULT LANDLORD ROOF FOR APPROVED TREAD. PADS. AF NO HVAC EQUIPMENT, DUCTS. ETC, SHALL BE INSTALLED IN DEMISING WALLS. AF. PAINT ALL EXTERIOR' EXPOSED METAL WITH PUS, PREVENTIIIVE PAINT. AG. ALL INSTALLED EQUIPMENT AND ACCESSORIES' ANDPIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC .AREA ZONE MODIFY INSTALLATION DETAILS TO CONFORM AS'REOUIRED. H. ALL TENANTS SHALL PROTABLE ABC FIRE EXTINGUISHERS AS REQUIRED BY THE LOCAL FIRE PREVENTION AUTHORITY HAVING JURISDICTION : EXTINGUISHERS SHALL BE LOCATED, TO HAVE AMAXIMUM. TRAVEL DISTANCE FROM ANY POINT IN THE TENANT SPACE, TO AN EXTINGUISHER OF SEVENTY ' FEET. THE MINIMUM REQUIREMENT SHALL BE TWO EXTINGUISHERS WHICH EME SHALL BE LOCATED IN THE SALES AREA AND UNE IN THE STORAGE AREA. (OR REAR OF UNIT.) NO EQUIPMENT SHALL BE INSTALLED IN THE CODE REQUIRED EXIT CORRIDOR. A CLEAR 44 INCH MINIMUM IS REQUIRED. (VERIFY WITH ARCHITECT:) J. ALL TENANT'S ROOFTOP HVAC EQUIPMENT SHALL BE PROVIDED VITH A MANUFACTURERS. OPTIONAL CONDENSER OIL GUARD TO PROTECT AGAINST HAIL DAMAGE, DEBRIS :AND VANDALS, SOUTHCENTER SEATTLE •A8WM17011 MECHANICAL DETAILS AND SPECIFICATIONS Sheet 3 of 6 R A P' P NG T E I ' IES ND I I ALL'''.. INS ALLED QU IPMENT ACCESSO M R M NT FOR EIS IC R UI EE S ❑RS SHALL BE INSTALLED PER' EQ 16RE''A ZONE 3 MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED L V REVISED 3a REVISED MAIM Sl, °••f9. SOAK, SASSED SY, UNIT NUMBER DBA SOIJTHCENTER MALL SEATTLE WA. THIS SHEET & TTG -01 MUST BE INCLUDED AS PART OF TENANT'S SU BMITTAL, TO THE LANDLORD. BIDDING CONTRACTORS AND FOR BUILDING PERMITS The Richard E. Jacobs Group FILE SCNTTM3 d1AtN0 MANmO TT - SOUTHCENTER MALL 7/15/98 1/15/96 L2\ 2 REVISED , 6/13/95 '4/13/95 OA11, MAIN JOS MAIM DATE RECEIVED CI OF TUKWILA PERMIT CENTER FLOOR SLAB NTS SECURE BASE TO CURB WITH LAG SCREWS 12' 0, MIN. OF 2 PER SIDE FABRICATED CURB SEE CURB DETAIL „ �26 ? EXISTING METAL DECK RIGID CONDUIT BY ELECTRICAL MOTOR OPERATED DAMPER CORNER TO RE CUT FOR CONDUIT ROUTING DUCT INSULATION SEE SPECIFICATION SECURE BASE TO CURB WITH LAG SCREWS 12' D.C. MIN. OF 12) PER SIDE FABRICATED CURB - SEE CURB DETAIL EXISTING METAL DECK DUCT INSULATION SEE SPECIFICATION REMOVE CONCRETE FLOOR FOR PIPE PENETRATION ONLY DU NUT CUT REBAR REPLACE CONCRETE SLEE' ✓E 1/2' CLEAR RiN 3:'4' CLEAR MAX. PACK WITH OAKUM & APPLr SEALANT AT TOP FOR GAS SEAT EL US WITH FLI]CIR> 1/2' WIDE x 3'4'DEEP RECESS Al PERIM. OF CONC. PATCH. FILL. WITH SEALANT FOR GAS SEAL. ISNIESSOMEMMINMESSI �1f1{= �1 1INNIMIIISMISNEMMIM1 _I ECHANIC ALLY ROUGHENED JOINT PIPE FORM UNDERSIDE OF SLAB - ANGER TUNNEL UNDER EXISTING SLAB Lip PIPING SIUL FURAL SLAB PIPE Pt 1 ETRAI I ❑N DE . NOTE. SEALANT TO BE MIN. OF 1'2' THICKNESS OF BFC BET ASEAL NO 169 BFC DIVISION OF ESSE CHEMICAL. CORPORA? ION OR APPROVED EQUIVALENT OF MINNESOTA MINING AND MANUFACTURING CO, DR BENJAMIN FOSTER NOTE' ALL DUCTWORK BELOW SLAB SHALL BE CONSIDERED CONFINED SPACE. INSECT SCREEN RESILIENT GASKET SEAL.. INTAKE BASE EXISTING INSULATION r SECURE CURB TO DECK W; SCRE WS 1P' O.C. MIN. OF 2 PER SIDE. i ANGLE FRAM (4) SIDES SEE CURB D ETAIL (>C NOTES. 1. H.V.A.C. CONTRACTOR TO COORDINATE INSTALL AT ON W /LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING B CUUNTERFLASHING INSTALLATION D.A. INTAKE GRAVITY RELIEF DETAILS 12 N.T.S. TT - 12 \ --" GREENHECK CRS- SERIES DR EQUAL RE ILIENT GASKET SEAL. EXHAUSTER BASE C IS" MG INSULATION SECURE CURB TO DECK W SCREWS 12' U.C. MIN. OF 12) PER SIDE. 3 /3'x1/4' ANGLE FRAMING (4) SIDES - SEE CURB DETAIL MOTORIZED DAMPER AS REQUIRED NOTES: L H.V,A.C. CONTRACTOR TO COORDINATE INSTALLATON W /LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING K COUNTERFLASHING INSTALLATION. EXHAUSTER DETAIL (TOILET, SMOKE, MISC,) N.T.S. TT -II EXISTING ROOFING MEMBRANE /ROOF SECURE BASE TO CURB WITH LAG SCREWS 12" D.C. MIN. OF 2 PER SIDE ONE PIECE WELDED ALUMINUM FAN SUB -BASE CONTINUOUS PIANO TYPE PIANO HINGE FABRICATED CURB SEE CURB DETAIL CORNER TO BE CUT FOR. CONDUIT ROUTING GAS LINE ON ROOF EXISTING ROOF DECK RIGID CONDUIT BY ELECTRICAL MOTOR OPERATED DAMPER GAS LINE SUPPORT SEE DETAIL O N.T.S. STEEL WASHER EXISTING ROOF CLEVIS HANGERS - PIPES 1 -1/4" & SMALLER 8' -0" MAX. O.0 PIPES 1 -1/2" & LARGER 10' -0" MAX. O.C. GAS LINE ALUMINUM ROOF UPBLAST FAN GREASE COLLECTION DEVICE IS REQUIRED. INSTALL PER MANUFACTURER'S REQUIREMENTS. TENANT MUST EMPLOY GREASE GUARD, TO INSTALL CALL I 600- 264 -6273 FOR INSTALLATION RESILIENT' GASKET, REQUIRED FREE 1 AREA SIZED ON 500 FT /MIN VELOCITY'., ANGLE IRON COPED EACH END TO FIT OVER JOIST CLAMP OR WELD ANGLE TO JOIST. VENTED CURB EXTENSION (AIR VENTS ON ALL(4) SIDES) RESILIENT GASKET FLASHING BY GREASE GAURD CONTRACTOR 16 GA. FABRICATED CURB -OFF DFTAD SEE DETAIL 26 FOR FRAMING. REQUIREMENTS 2 -0" MAX. DISTANCE 1ST SUPPORT GAS VALVE7 FOR PIPE AND /OR CONDUIT FLASHING THRU ROOF SFE DETAIL Og 4" DIRT LEG 3" MIN. ABOVE ROOF 3/8" ROD (MIN.) DIRT LEG MIN. 6" AT EACH CHANGE OF ELEVATION. ALUMINUM ROOF UPBLAST FAN RELIEF' /R❑DF EXHAUST FAN DETAIL N.T.S. TT NOTE TO BE USED FOR HVAC RELIEF /SMOKE RELIEF AND ROOF EXHAUST FANS. DOUBLE NUTTED RESILIENT, GASKET', SEAL FAN BASE HOLD DOWN CLIP EXISTING INSULATION TT -21 SECURE CURB TO DECK W/ SCREWS 12' MIN. OF 2 PERI SITE -NON DUCTED EXHAUST AIR SYSTEM ABOVE CEILINGS INSTALLED 2' DEEP SOLDERED LIQUIDTIGHT- DRIi PANS 3'x3'% ANGLE FRAMING i4) SIDES- SEE CURB:' DETA NOTE: H,V.A.0 CONTRACTOR TO COORDINATE INSTAELATON W/ LANDLORD'S ',ROOFER FOR .. PROPER'. SEQUENCE TO PERMIT FLASHING BCOUNTERFLASHING INSTALLATION.: GROUND JOINT UNION EXISTING INSULATION GAS LINE (MIN. SIZE 1-I /45 HUMANE PAD "8'x18' (MIN, ROOFING 1 ■AI mum NOTES. SECTION 1. SUPPORT REQUIRED EVERY 10', D.C. AND' AT CHANGES IN DIRECTION.: 2. INCREASE HEIGHT AS REQ'D FOR ROUTING ABOVE ROOF. MOUNTED. I'l ACCESSORIES SUCH AS EXPANS ON JOINTS, 3. PVC IPIPE SLEEVE SHALL 13E THE NEXT SIZE PIPE DIAMETER LARGER THAN THE OUTSIDE. DIAMETER OF THE PIPE. GAS LANE SUPPORT "' DETAIL TT -3 EXISTING METAL DEC INSUL IE THE LTD LINE 0 A POINT 1' BEYOND DS FILLER- SEAL ENDS PLAN AS SECURE CHASE TO METAL DE CK AT ' 1/4 PEINT$ VITH 2x2x1 I/2 V DE 16 "GAUGE SHEET. METAL CLIP ANGLES AND FASTEN TO, CHASE VITH SCREWS. SECTION - "A "' NOTE CUi SLOTTED RULES tN COVO CLOSURE PIECE FOR PIPING /4' SMALLER ER AN THAN OVERALL CAULK PERIMETER INSULATION AND FORCE IN TO. PLAC CAULK PER[MCTEROF PIPES. SECLOSURCURE TE,PIU B T PIPING AND BEHIND COVER. O LURE CAP. , ► �l i e/IY>t � grielraidiV ®®!311111■s■ SECTION "B " 3 "x3 "x1/4" An GLE ANCHOR PIPE TO ANGLE WITH STD. U -BOLT GAS PIPE MIN. 1 -1/4" GAS PPE THROUGH ROOF DETAIL 5 G� EXH•UST AIR DUCT NON -COMB. INSULATION -CUT TO FIT AS REQ'D. LOCATE AWAY FROM BUILDING WALL 6. 15' D" FROM OUTSIDE AIR INTAKES EXTEND FLASHING OVER TOP OF INSULATION AND FASTEN AT B'O,C. CONDUIT SEE DETAIL 9 FOR CONDUIT ROOF PENETRATIONS TAIL EXISTING INSULATION EXISTING ROOF DECK N T 1. FOR BALLAST SYSTEMS REPLACE BALLAST AFTER WORK IS COMPLETED. 2. NEW INSULATION TO MATCH EXISTING INSULATION HEIGHT AND OF THE SAME OR GREATER THERMAL RESISTANCE VALUE.'. 3. ROOFING TO BE INSTALLED AND FLASHED -IN WITH MATERIALS .TO MATCH EXISTING. INSTALL MATERIAL PER ''MANUFACTURER'S RECOMMENDATIONS'. 4 HVAC CONTRACTOR TO ODOR ➢INATE. INSTALLATION W ITH LANDLORD'S' ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING ANDCOUN iERFE SPING INSTALLATION 5 USE" SELF DRILLING FASTENERS FOR METAL DECK,TDUGLES FDR GYPSUM DECKS RESTAURANT GREASE FAN AND PAN D,ETAIIL ( BOLTED PIPE CLAMP CONTINUOUS FASTENING STRIP AND APPROVED FASTENERS AT B CAP SEAL OFF METAL DECK FROM DUCT OPENING W/26 GA. SHEET METAL ALL SIDES t /4' x 6' LG. GALVANIZED STEEL LAG BOLTS- BOLTS TO HOLD BLOCKING TOGETHER M 1/4' x 2' LG. LAG BOLT 1 111 FASTEN PIPE CLIP TO BLOCKING II AS REC '7: PLAN PLUMBING CONTRACTOR IS RESPONSIBLE TO PROVIDE' GAS LINE SUPPORTS FOR ALL GAS LINES INCLUDING TENANTS PIPE SLEEVE AND CLIP. OUTLINE OF EQUIPMEN VIBRATION ISOLATION GROMMET V RUBBER SHEAR PAD OR SPRING ISOLATOR FOR ROOF MTD. EQUIPMENT PATE SHEET METAL CURB CAP PATE CO. EQUIPMENT SUPPORT STYLE ES -2B 5- 1/2'x15' MIN. 18 GA.- ALL WELDED FIRE TREATED WOOD BLOCKING. ALL (4) SIDES OF CURB. NOMINAL 6' WIDE x THICKNESS TO MATCH INSULATION THICKNESS. NOTCH WOOD TO LAY .FLAT OVER CHANNEL. REINFORCED JOIST INDICATED ON MECHANICAL AND /OR STRUCTURAL PLANS WITH 1. STUB COLUMNS 2. BLOCK OUT AREAS 3. JOISTS - MARKEDWITH AN ASTERISK (x> 4. VERIFY LOCATION WITH LANDLORD REPRESENTITIVE PVC PIPE SLEEVE. SEE NOTE q3 I' WIDE 20 GA. GALVANIZED STEEL PIPE CLIP FOR THE PVC SLEEVE (2) 4'x4'. WOLMANIZEB WOOD BLOCKS IN 4O ME �AUWAWfW� f6'4INj A 15/8' UNISTUT SECURED AT EACH END VITH.I /4'. LAG BOLTS (P -4000 CHANNELS) SUCTION OR HOT GAS INSULATED LIQUID ELECTRICAL CONDUI UNISTUT PIPE CLAMPS NOTE LIQUID LINE PIPE CLAM TO BE USED AS A GUIDE OLY. !NS TALL 6' LENGTH INSULATION.. PIPING CURB SUPPORT PATE CO: I ES STYLE IA 12 HIGH MIN .18 GA V/2,4' NAILER !CURB TO BE MA% U C HUMANE PAD ON TOP OF ROOFING ET ROOF JOTS PLAN SECTION A METAL DECK BOLT CHANNEL TO EACH JOIST CHANNEL SUPPORT ON TOP OF DECK EQUIPMENT SUPPORT CURB ROOF MTD. EQUIPMENT LAG BOLT VITH FLATWASHER SECURE CURB CAP TO CURB WITH SHEET METAL SCREWS AT 12' OC PATE WOOD NAILER RIGID INSULATiU'- I,..LKNESS TO MATCH NAILER OVERHANG - ADHERED TO CURB CUT INSULATION TO MEET WOOD BLOCKING EXISTING INSULATION EXISTING METAL DECK FASTEN CURB TO CHANNEL AT 24' O.C. MAX. (MIN. 4 PER CURB) CONDENSING UNIT AND OTHER SPECIAL /�8 ROOF MOUNTED EQUIPMENT SUPPORT DETAIL NTS TT -18 BOLT CHANNEL TO EACH JOIST WITH MACHINE BOLT, NUT AND WASHER. DO NOT BRILL JOIST NOTES 1. UNITS UP TO 1E380 LBS. TOTAL WEIGHT SHALL BE SUPPORTED MIN.(2) JOISTS. 2; UNITS GREATER THAN 1880' LBS. BUT' LESS THAN 2800 LBS TOTAL WEIGHT SHALL BE' SUPPORTED ON MIN.(3)JOISTS. 3, HVAC CONTRACTOR TO ALLOW ROOFER TO INSTALL COUNTERFLASHING PRIOR TO INSTALLING PATE CURB CAP. FABRICATED RE SEE CURD DE TA 26 ECURE'' CURB IO METAL DECK AT 12'O.GMAX (MIN.. 2' PCR SIDE) IB GA GAL V. 6 - DIA. GALV. METAL REFRIGERANT MIL LURE CHASE FOR LOWER TENANTS ONLY SECTION - "C" SUCTION. CONDUIT INSULATED COVER LIDUID REFRIGERANT PIPING ROOF CHASE AND PIPE SUPP DETAIL NOTE 'SHOW REFRIGERANT PIPING ROUTING FROM CONDENSER TO AIR HANDLING UNIT ON PLA NOTE ALL SEAMS TO DE SOLDERED Vq TER TIGHT ET AL CQVER VITH 1' INSULATION JUNCTION BO% FASTENED TO METAL CURB - CLOSURE PIECE FASTEN COVER AT I2'0 .C. TMRUCURB. CAP RESILIENT GASKET RIGID INSULATION TO MATCH THICKNESS EF WOOD NAILER. ADHERE i0 CURB S HVAC CONTRACTOR TO COORDINATE INSTALLATION WITH LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING' AND COUNTERFLASHING INSTALLATION.'. .2.�CHASE AND COVER INSTALlT 1' TMI4 NFPA COATED, PINNED: ON 4' CENTERS AND GLUED TO SHEET METAL.. ;LAULKLNG TO BE SILICONE BASE ANO VATERPRO[4 '. Ale SOUTHCENTER ��f y UNIT NUMBER The Richard E. Jacobs Group AN' REVISED DRAWN q■ ROE SCALE ROAM SY. SEATTLE, WASHINGTON MECHANICAL DETAILS AND SPECIFICATIONS Sheet 4 of 6 REVISED SOUTHCENTER MALL SEATTLE WA. REVISED ISLE NAM SCNTTM4 DBA THIS SHEET & TTG -01 MUST BE INCLUDED AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS AND FOR BUILDING PERMITS l owir OATS DRA111818 MII ®6 TTM -4 MCAT)OI SOUTHCENTER MALL 7/15/98 1 /1`5/ 9 6 7/10/95 APPLIANCE HEAT GAIN CALCULATIONS APPLIANCE NO FUEL/ MOTORS INPUT K.W. FACTOR INPUT BTUH SENSIBLE FACTOR SENSIBLE HEAT GAIN LATENT FACTOR L H GAIN COOKING E�022,, I 0 3000H -Nn GAS - a . .33 .17 ELECTRIC 3413 .33 17 �3a 00f GAS JO ELECTRIC 3413 .14 - i a S' _ MOTORS HP 2545 .30 ELECTRIC '.3413 .30 OTHERS TOTALS ® KITCHEN EXHAUST FAN MANUFACTURER MOTOR H.P. CFM POWER V/ H2/ MODEL FAN R.P.M. E.S.P. DRIVE BELT MOUNTING CURB APPLIANCE SCHEDULE APPLIANCE NUMBER APPLIANCE FUE'_ TYPE GAS %ELECT, FUEL RATING BTUH!KW' HOODED UNHDODEO 4 MI ROOFING MEMBRANE INSULATION REINFORCED JOISTSITNDICATEDI ON MECHANICAL AND /OR STRUCTURAL. PLANS WITH 1 .BLOCK OUT AREA I 2 JOIST MARKED W/ ASTERISK. • ■ POWER &CONTROL. WIRING THRU ROOF SF OFTA F L O I ®� W FOR PLUMBING VENTS TURN LEAD FLASHING DOWN INTO VENT PIPE A MIN. OF 1" BELOW TOP OF ':PIPE LB. VIRGIN LEAD VENT PIPE 1;'.. FOR BALLAST SYSTEMS, REPLACE BALLAST AFTER WORK IS COMPLETED 2 '.. 4 LB. LEAD FLASHING SHALL BE 1/4' MAX DIAMETER LARGER THAN PIPE ALL JOINTS TO BE SOLDERED 3 FLANGEISHALLI BE SET BY ROOFER CONTACT L L FOR LIST OF APPROVED ROOFING .CONTRACTORS I I 4. ALL ROOFWORK TO BE 'PERFORMED BY MALL APPROVED ROOFING CONTRACTOR', 5 VENTS SHALL BE A MINIMUM OF''..10' 0" FROM OUTSIDE AIR INTAKES_ TYPICAL DETAIL LEAD BUR NTS. I "METALBESTOS" TYPE RV FOR 8" OR SMALLER TYPE QC FOR 10" OR LARGER DOUBLE WALL. "METALBESTOS" TALL CONE TURN DOWN FLASHING FLANGE 2" ALL SIDES TO FORM CURB CAP. (SOLDER CORNERS.) RESILIENT GASKET — MIN. OF 3' -0" HEIGHT SHALL BE AS REO'D BY LOCAL CODE. LOCATE 25' -0" FROM BLDG. WALL AND 15' -0" FROM OUTSIDE AIR INTAKE. CONTACT LANDLORD. . NOTES: SET CURB LEVEL', WITHIN UNIT.. MFRS RECOMMENDATIONS RESILIENT! GASKET CONTINUOUS FIRE (TREATD' WOOD NAILER B Y UNIT MANUFACTURER FULL ROOF TOP EQUIPMENT CURB PROVIDE STL SHIMS BETWEE CURB & CHANNEL EE LI NG 24' 0 C. IF F R' L EO D 0 LEVEL CONNECT TO UNIT .DUCT LINER '.,.WHERE REVD �N► MINIMUM CLEARENCE i. H.V.A.C. CONTRACTOR RTC; OINATE INSTALLATION W / LNDLORD'S ROOR FOR PROPER SEQUENCE TO PER RD FLASHING & CO INSTALLATIO 2. CURB INTERNAL SIZES: FOR FLUES 3" THRU 5" ROUND -9x9" CURB. FOR FLUES 6' THRU 8" ROUND - 12"x12" CURB. FOR FLUES GREATER THAN 8" ROUND CONSULT WITH THE LANDLORD. GAS FLUE THRU ROOF DETAIL 'A®® b •® ®7 ®W ®',,.. V s3 CHANNEL '. ■ OST & CHANNEL DRILL JOIST. • . BO EA NUT WASH. DO NOT -•- DUCTWORK SEE NOTE #2 STAINLESS STEEL CLAMPING RING PRE= MOLDED '.' PIPE T SEAL Ii.uv.V. -,r 4141 ' c se e "rte B :� Imo'' _ ®: :: � '' RIGID INSUL.'TO �' M .ICKNESS I. • �9 OF,NAILER ADHERED ` :: J TO CURB ATCH TH 1 � ET CUT INSUL. TO M WOOD BLOCKING UNION IN' GAS PRESSURE REGULATOR (WHERE REQUIRED) GAS COCK FIRE TREATE W000 BLOCKING. ALL FOUR WIDE THICKNESS. CURB . NOM 6' WIDE % THICKNESS. 70 MATCH INSULATION THICKNESS SECTION "A ROOFING 'TO CHANNEL( NO PE S TD MACHINE 4) R UNIT I "METALBESTOS CAP BIRDPROOF "METALBESTOS" STORM COLLAR SET IN SEALANT SECURE TALL CONE TO CURB MIN. 2 PER SIDE -® 12 O.C. FABRICATED CURB SEE CURB DETAIL <28) SECURE CURB TO DECK w/ SCREWS 12 C.C MIN. (2) PER SIDE SECURE FLUE TO DECK AT 1J4 POINTS WITH BIN- OF (4) 2"x1 -1/2 WIDE 16 GA. SHEET METAL CLIP ANGLES RIVETED TO FLUE, SECURED TO DECK. FOR MODEL CC VENTS USE" MFTALBESTOS" SUPPORT PLATE. TT -4 GAS SERVICE'. (WHERE REOUIREI]) COPPLR NOT PVC I TSLL NiE DRAIN (FULL SI ( ZE), WATER CUT -OFF. MASTIC I'1I UM RUBBER —\ ROOFING MEMBRANE W4LW ,g®®®I►® INSULATION DO NOT TRIM DECK FLANGE NOTES: : 1 PRE MOLDED PIPE SEAL CANNOT BE CUT VERTICALLY'.. TO BE INSTALLED 2 PRE MOLDED PIPE SEAL MUST HAVE INTACT RIB AT TOP EDGE REGARDLESS OF PIPE DIAMETER 1. 3 WHEN PREFABRICATED PIP SEAL CANNOT BE INSTALLED, USE FIELD FABRICATED PIPE SEAL SEE ALTERNATE PIPE FLASHING DETAIL, 4 FOR BALLAST SYSTEMS, REPLACE BALLAST, AFTER WORK IS I COMPLETED. I 5. FLANGE SH BE SET I BY ROOFER. CONTACT L L. ( FOR UST 1 OF APPROVED ROOFING1 CONTRACTORS I LL . 6 A ROOE`NORK TO BE PERFORMED BY MALL APPROVED ROOFING CONTRACTOR 7 VENTS SHALL BE A I MINIMUM OF 1C,0".' TYPICAL DETAIL PREMOLDED RUBBER ROOF SPLICING CEMENT' LAP SEALANT EXISTING INSULATION EXISTING METAL DECK MIN. X12 "xi 8"x THICK, SPLASH 2" BLOCK 2 4' HUMANE MANE ROOF x2 4 H PAD SPUD BACK GRAVEL MASTIC TO ROOF INSULATION MEIN DECK JOIST O SUPPLY 'AIR,MAIN VOLUME DAMPER: i'. -1/2 F IBERGLASS —/ INSULATION W /'.. FOIL FACING IN OF FLEXIBLE DUCT (MOUNTING DETAIL' METAL DECK OFI SAME,'. PROFILE( AND GAUGE AS E % 1ST INC. SECURE f0 ROOF DECK 1 WITH, SCREWS 6" O:C. I INTO '.TOP'. OF FLANGE I I, x %ISTINC ANGLE FRAMF� PROVIDE'J.NEW . 3 i /4 ; AAAAAANCLE FRAME IF NONE EXI JOINT IN ROOF INSULATION M T BE ' SUPPORTED1 BY METAL ECK I GALVANIZED SHEET, METAL DUCT g IIU•UIII MANI OF EXISTING ROOF DECK NEN.'ROOF INSULATION OPHO1rit111MOU ODIUM 1 � i ®'d ®v0 ®1111! 8 "MIN SECTION 1-1 (FOR OPENING LARGER THAN 16 ") ROOF INSULATION. 11 J ®sJ I ROOF I OPENING 20 GA CAI, STEEL ,.R `MIN `IJI SECTION 2 -2 (FOR OPiENINGS 16" d SMALLER) .NDTFS 1 1. NEW INSUTATI N TO H ATCH E %ISTINC INS ILLATION HEIGHT & TH Pr SAME OR GREATER THERMAL RESISTANCE VALUE.,' '. I 2 ROOFING TO BE' INSTALLED AND FLASHED 'IN WITH MATERIALS HO MATCH( EXISTING INSTALL MATERIALS PER MANUFACTURER'S RECOMMENDATIONS. I / ,, 3 IF METAL DECD FOR OPENINGS ■ LARGER THAN 16" IS NOT AVAILABLE.' CONTACT P" ✓� LANDLORDS STRUCTURAL ENGINEER REPAIRS TO THE METAL DECK SYSTEM NTS.. : TT -2 METAL STRAP CLAMP (TYPICAL) 2' PLACES INSULATED FLEXIBLE CONNECTION. (MAX. 5' -0') IN VERTICAL ONLY 'SUPPLY AIR DIFFUSER JOIST NEW INSULATION F (OPNINGS i6 SEMALLER FOR OPENNG iARGER i FIAN I 6 " JOIST %1ST PROFIL '. ALTERNATE.' F ERMI WILL TPI PROFILE EXIS CK 70 MATCH AND GAGE. 9FlLES ARE a DED.NEW EST" WITH jU\1K11U+1 '' DRAWN 11, RCP ALE RAKE° HE NA16 SCNTTM5 piA'•N• Mltib IACATIOM REVISED REVISED' ' DBA SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS'' AND FOR BUILDING PERMITS REVIWON• SBUT•CENTER ALL ATE. 1/•/01 JOS MAW 7/15/98 /15/96 2 "x4" FIRE TREATED WOOD NAILER. SECURE TO CURB AT 12 "O.C. (MIN. 2 PER SIDE). FABRICATED 16 GAUGE GALVANIZED SHEET METAL ALL WELDED CONSTRUCTION. PAINT AFTER PAINT WITH RUST RESISTANT AFTER FABRICATION. FABRICATE HAT. OF CURB SO THAT HGTABV.ROOFING SURFACE IS A MIN. 10 ". FOR HOOD EXHAUST SYSTEMS SEAL OFF OPENINGS IN DECK W/ METAL PLATE SECURE CURB TO DECK WITH SCREWS AT 8" O.C. 3 "x3 "x1/4" ANGLE FRAMING ALL SIDES OF DUCT PENETRATION. WELDED OR BOLTED TOGETHER. COPE ANGLES PERPENDICULAR TO JOISTS TO ALLOW TOP LEG TO SET ON TOP CHORD OF JOIST. WELD OR CLAMP ANGLES TO JOIST. ANGLE MAY BE OMITTED ON SIDE OF DUCT OPENING WITHIN C OF JOIST. REINFORCED JOISTS INDICATED ON MECHANICAL AND /OR STRUCTURAL PLANS WITH: 1. BLOCK OUT AREA 2, JOIST MARKED W/ AN ASTERISK. • ..LAP. ANGLE OVER ' JOIST'. .MIN. OF 2" 5" 16.7 # /FT. CHANNEL SUPPORT ON TOP OF DECK. 6' -0' 0 C MAX: SPAN TWO JOIST MIN. OUTLINE OF R.T.U. 4' MIN. FULL PERIMETER R.T.U. CURB .MAIN WALKwAY BY LANDLORD BY TENANT METAL DECK. ANGLE NOT REO D WHEN DECK OPENING IS WITHIN 6' OF JOIST , 3 -; x1/4' DUCT r FRAMING TYP. 4 SIDES /OPG V l i/ 11 PoWER & CONTROL II�VI���! �Iil WIRI•G THRU ROOF X11 SFF DRAM / WHEN' CURB PRO BEYOND JOLST THAN 18' EXTEND C HANNEL TO NEXT JOIST. METHOD #1 (TYPICAL FRAMING FOR RTU'S UP TO 1880 LBS. TOTAL WEIGHT) RTU STRUCTURAL FRAMING PLAN NT S. SEE NOTE SEE NOTE k2 12" MIN TREAD PAC ( CUNSULT LANDLORD ROOFER FOR TREAD PAD) /2' SECTION 'A' USE THIS DETAIL FOR NON REMOVEABLE EQUIPMENT ROOF TREAD PAD LAYOUT 86 N.T.S. TT -86 2"x2" FIRE TREATED WOOD NAILER. SECURE TO CURB AT 12 "0.C.(MIN (2) PER SIDE) USE THIS DETAIL FOR REMOVEABLE EQUIPMENT RIGID INSULATION TO MATCH THICKNESS OF NAILER. ADHERED TO CURB. CUT INSULATION TO MEET WOOD BLOCKING T. EXISTING INSULATION TO REMAIN. REPLACE ALL DAMAGED INSULATION TO MATCH EXISTING_ METAL DECK EXISTING JOIST FIRE TREATED BLOCKING ALL (4) SIDES OF CURB. NOMINAL 6 "WIDE x THICKNESS TO MATCH INSULATION THICKNESS. NOTES: 1. INTERIOR DIMENSIONS TO BE DETERMINED BY SPECIFIC EQUIPMENT. SEE DETAILS. 2. EXTERIOR MIN. DIMENSIONS OF CURB FOR FLASHING AND COUNTERFLASHING SHALL BE 12 "x12 ". DETAIL OF FABRICATED CURB (26 N.T.S. TT -26 FOR HOOD EXHAUST OR WHERE CODE. DOES NOT PERMIT TREATED WOOD. BLOCKING, OMIT WOOD BLOCKING AND UTILIZE ROOFING MATERIAL PER CODE. r 5 x 6.7# /FT. CHANNEL SUPPORT ON FOP OF DECK 6' -0 O.C. MAX. SPAN. MINIMUM OF 3 JOISTS LAP ANGLE. OVER JOIST MIN. OF 2" OUTLINE OF R.T.U. FULL PERIMETER. ROOF R.T.U. CURB ANGLE NOT �'l WHEN DECK OPENING I WITHIN 6' OF JOIST MINIMUM. ANGRAMINGIOR DUCT LE PE TYP..4 SIDES /OPC N.T.S. III ®1 •� i i: • — ISrv■•■•:: i: rr: ■■ II 1 10 ITERED JOINTS WELDED AND GROUND SMOOTH ON CURB (TYP.) METHOD #2 (TYPICAL FRAMING FOR RTU'S BETWEEN 1880 LBS. & .2800 IBS: TOTAL WEIGHT) RTU STRUCTURAL FRAMING PLAN SEE NOTE #2 STAINLESS STEEL CLAMPING RING SOLDER JOINT '. ROOF JOISTS LAP ANGLE MIN 2" OVER JOIST ANGLE FRAMING FOR DUCT PENETRATION. PLAN EACH JOSDN(TYP CFNFRAL NOTES( i FIELD VERIFY LOCATION OF RTiI PRIOR 10 INSTALLATION. 2 . ALL ISMOWN 81 TENANT "..'COLRR. UNLESS ,OTHERWISE NOTED 3 PRONOE INSULATION IF'I WOOD NOT PERMITTED BY CODE , MIlE SO. LEAD METAL DECK '�, FLEX DUCT �. CONNECTION '.'�. RTU STRUCTURAL FRAMING PLANS AND SECTION, TT I 1 4 ANGLE FRAMING F DUCT. PE NETRATION, WEILDED ORBOLTED:OCETHER. COPE LA MLL PERPENDICULAR TO JOISTS 70 ALLOW TOP "LEG ON TOP CHORD OF JOS7, 'WELD OR CLAMP ANLES O T JOIST ANGLE MAY I 0G IT H I N 6- SIDE 'OF.000TI :. OPENING WITHIN 6i OF JOIST PIPE /CONDUITI OR VENT THROUGH ROOF FLASHING 'DETAILS N.T.S. .!FIELD VERIFY TYPE OF ROOF AND USE APPROPRIATE DETAIL(. (BUR (RUBBER) SOUTHCENTER SEATTLE, WASHINGTON MECHANICAL DETAILS AND SPECIFICATIONS Sheet 5 of 6 UNIT NUMBER SOUTHCENTER -MALL SEATTLE WA. THIS SHEET & TTG -01 MUST BE INCLUDED AS PART OF TENANT'S NUMMI IIMMW The Richard E. Jacobs Group RECEIVED OF TU %'I A P RMIT' GENE H,,: i" RUBBER SHEAR PAD' OR SPRING ISOLATOR. FOR ROOF MOUNTED EQUIPMENT LANDLORD PROVIDED CONCRETE EQUIP. PAD ROOF MOUNTING EQUIPMENT.'. LAG BOLT WRIT FLAT WASHER —T EXPANSION .BOLT ROOF MOUNTED EQUIPMENT' SUPPORT DETAIL NTS TT -135.. o rr- THE BON rA„ rff %�fie rii /4%% ����y / %/ / ////.__ ._ r t yrA/ArApA rreffs, r." r re # 1 p wfo' %/////% / ®i% NORDSTROM SEARS NORDSTROM SEARS CD 0 l3 1.. THE "SPECIAL BUILD i !G COI DITIONS NOTED ON THIS DRAWING SHALL BL CONSIDERED BUILDING /CONSTRUCTION RESTRICTIONS. I ALL CONDRIONS!' MUST BE ''FIELD. VERIFIED BY TENANT. 7, NONE OF 1HE NOTED CONDTIONS MAY BE ALTERED IN AN WAY_ NO FLOOR PENETRATIONS ARE PERMITTED UNLESS REVIEWED AND APPROVED BY THE LANDLORD'S ENGINEERS AND ALL PRESIDING !GOVERNMENTAL AUTHORITIES NOTE _111111111110M1 v' cm1F-Ji= L r= C� LANDLORD'S O.A. 'DUCt(S 5" REF CC SLAB ON GRADE 9 -1/2" REINFORCED STRUCTURAL SLAB TYPICAL UNLESS OTHERWISE NOTED. THE BON r L MS 3. THERE ARE LOCATIONS BELOW ITHE FLOOR SLAB AT WHICH, SPECIAL EQUIPMENT HAS ,BEEN LOCATED ! �I FIELD. VERIFICATION OF THESE IS THE TENANTS' RESPONSIBILITY. '.4 UNDER FLOOR AREAS ARE HAZARDOUS LOCATIONS DUE ro CONFINED SPACES AND FLAMAA E' GAS FORMATION Q 5 DO N FLOORS STRUCTURAL DAMAGE WILL ESULT i r� O FOOD 1 COURT ,A Iwo 1" 1111I1 FOOD COURT O oho- O O 1111111 k MERVYN'S' JCPENNEY NMI The Richard E. Jacobs. Group Q3 REVISED REVISED 1'.! REVISD St! WT, WV. DBA SUBMITTAL TO THE !LANDLORD BIDDING CONTRACTORS AND FOR BUILDING PERMITS DATE GOWN DATE NAOS ! 1 WHO NUNEENe TTM- e"'"F SOUTHCENTER MALL 6/26/96 5/7/96 RECEIVED CI�1' OF'.TUM.NILA 1/,15/96 ?E RIWIT CENTER GALVANIZED ANIEED PIPE STRAPS & CADIUM PLATED BOLTS (TYPICAL) CONDUIT 3 "x3 "x1/4" GALVANIZED STEEL ANGLE 6 -0 O.C. 1/2" EXPANSION SHIELD EQUIPMENT PAD SLAB CLEANOUT INSTALLED BY LANDLORD l•"1 1 / /w it f I II I �IIY' 'hJ • • a • s • A i \ \ \ % — \\� \ a CAST IRON 'NO HUB' % \ \ \-•�\ PIPING SHALL BE USED BELOW UPPER LEVEL FLOOR SLAB TO SERVE UPPER LEVEL TENANTS. EXISTING — BY LANDLORD CAST IRON SPOOL PIECE INVERT ELEVATION AS SHOWN ON LANDLORD'S DRAWINGS NOTE: 1. TENANT SHALL CONNECT SANITARY DRAIN TO CONNECTIONS PROVIDED BY LANDLORD. 2 TENANT SHALL NOT MODIFY' LANDLORD'S DRAIN OR MAKE CONNECTIONS TO SANITARY 3. ABOVE AND UNDERGROUND COUPLINGS SHALL, BE CLAMP —ALL" DRAIN COUPLING MODEL —HI 10R0 1 4. NO PVC. PIPING SHALL BE ALLOWED IN RETURN 'AIR PLENUMS 5 IF EXISTING LANDLORD PROVIDED UPPER. SANITARY TENANT CONNECTION ,CANNOT BE USED, CONTRACTOR SHALL USE LOWER ALTERNATE SANITARY CONNECTION_ 6. TENANT MAY USE CAST IRON BELL AND SPIGOT WITH APPROVED COMPRESSION FITTINGS BELOW GROUND. TENANT SANITARY PIPING DETAIL /' \ N.T.S. 4" IN PIPE SUPPORT DETAIL Q9% NTS TT -135 L NO HUB CAST IRON PIPING ABOVE 9 . — 0 . COUPLING (SEE NOTE 3) PVC TO A MAXIMUM OF 9' — 0" ABOVE FIN. FLR. PVC /ABS STAMPED ASTM (( D2665 -78 (SEE NOTE 6) COUPLING (SEE NOTE 3) SEE NOTE 5 FOR ALTERNATE SANITARY CONNECTION GALVANIZED NUTS ROOF MERVYN'S JCPENNEY SOUTHCENTER SEATTLE, WASHINGTON MECHANICAL DETAILS AND SPECIFICATIONS Sheet 6 of 6 j74142- UNIT NUMBER SOUTHCENTER MALL SEATTLE WA. THIS SHEET & TTG -01 MUST BE INCLUDED AS PART OF TENANT'S