Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M01-040 - SOUTHLAND INDUSTRIES
+,t City of Tukwila Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M01 -040 Type: B -MECH Category: NRES Address: 13400 INTERURBAN AV S Location: Parcel #: 000300 -0115 Contractor License No: SOUTHI *044MH TENANT OWNER CONTACT CONTRACTOR CONTRACTOR * * * * * * * * * * ** * ** ******* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ...,i 6 C Center Aut prized Sign ture Date ere certify that I have read and examined this permit and know the same 't and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate o,: cancel, the provisions of any other state or local laws regulating construction . or the performance of work. I am authorized to sign for and ******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: . ADD TOILET EXHAUST ON 1st. FLOOR. UMC Edition: 1997 obtain this Signature: SOUTHLAND INDUSTRIES 13400 INTERURBAN AV S, TUKWILA, WA 98168 HILL HAROLD W PO BOX 700, MERCER ISLAND WA 98040 ROBBYN GLISSON 13400 INTERURBAN AV S, TUKWILA, WA 98168 SOUTHLAND INDUSTRIES 17941 FITCH, IRVINE, CA 92614 SOUTHLAND INDUSTRIES 17941 FITCH, IRVINE, CA 92614 ilding permit. 1 _F : This permit shall become null 180 days from the date of iss abandoned for a period of 180 MECHANICAL PERMIT Valuation: Total Permit Fee: (206) 411 -3670 Status: ISSUED Issued: 03/07/2001 Expires: 09/03/2001 Phone: Phone: 206- 283 -1732 Phone: 206- 321 -7252 Phone: 206 - 321 -7252 2,000.00 51.75 Date: 7 n :Print Name: LOICin reDne Title T'=1A and void if the work is not commenced within uance, or if the work is suspended or days from the last inspection. OJECT NAME: Y :`NUMBER: M01 -040 SOUTHLAND INDUSTRIES TE'ADDRESS :. 13400. INTERURBAN AVE S Original Plan Submittal Response to Correction Letter # DATE: 03 -02 -01 SUITE NO: Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: Buildi� vision AwG 3 -I4 -D Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Please Route TUES /THURS ROUTING: REVIEWER'S INITIALS: PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ,FL Fire Prevention ICI 3 -6Q ( Structural Incomplete n Structural Review Required U CORRECTION DETERMINATION: Approved n Approved with Conditions REVIEWER'S INITIALS: Planning Division Permit Coordinator Not Applicable No further Review Required Not Approved (attach comments) U DUE DATE: 03- -06-01 Comments: n DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE 04 -03-01 Approved 111 Approved with Conditions Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: DUE DATE I DATE: DEPARTMENTS: Building Division Public Works Complete n PLAN REVIEW /ROUTING SLIP TIVITY NUMBER: M01 -040 DATE: 03 -02 -01 PROJECT NAME: SOUTHLAND INDUSTRIES ',:SITE ADDRESS: 13400 INTERURBAN AVE S SUITE NO: _ Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # 1 After Permit Is Issued Fire Prevention' Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Comments: TUES /THURS ROUTING: Please Route n Structural Revi: , ired n No further Review Required REVIEWER'S INITIALS: ' DATE: Z-CO t APPROVALS OR CORRECTIONS: (ten days) Approved LI Approved with di •ons REVIEWER'S INITIALS: CORRECTION DE i ERMINATION: Approved W ROUIt.DOC srr� n n Planning Division Permit Coordinator DUE DATE: 03- -06-01 Not Applicable I DUE DATE 04 -03-01 Not Approved (attac co ments) n DATE: a DUE DATE Approved with Conditions Ti Not Approved (attach comments) n n REVIEWER'S INITIALS: DATE: MDR _ CC PERMIT NO.: MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 00002 Pre - construction ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation/Indoor AQC ❑ 00610 Chimney Installation/All Types ❑ 00700 Framing ❑ 01080 Woodstove ❑ 01090 Smoke Detector Shut Off E 01 100 Rough -in Mechanical ❑ 01 101 Mechanical Equipment/Controls ❑ 01 102 Mechanical Pip/Duct Insul p 01 105 Underground Mech Rough -in ❑ 01115 Motor Inspection ❑ 1400 Fire Final - 01800 Final Mechanical ❑ 04015 Special -Smoke Control System CONDITIONS 0001 No changes to plans unless approved'by Bldg Div ❑ 0014 Readily accessible access to roof mounted equipment ❑ 0016 Exposed insulation backing material ❑ 0019 All construction to be done in conformance w /approved plans ❑ 0002 Plumbing permits shall be obtained through King Co (�/ 0027 Validity of Permit L� 0003 Electrical permits obtained through L & I ❑ 0036 Manufacturers installation instructions required on site ❑ "BTU maximum allowed per 1997 WA State Energy Code" ❑ 0041 Ventilation is required for all new rooms & spaces ❑ "Fuel burning appliances ❑ "Appliances, which generate...." ❑ "Water heater shall be anchored.... Additional Conditions: If TENANT NAME: FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace/Burner to 100,000 BTU (qry) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor - mounted Heater (qry) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qry) Boiler /Compressor to 3 HP /100,000 BTU (qry) to 15 HP /500,000 BTU (qry) to 30 HP /1,000,000 BTU (qry) to 50 HP /1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qry) Air Handling Unit to 10,000 cfin (qry) over 10,000 curt (qty) Evaporative Cooler (qry) Ventilation Fan (qry) Ventilation System (qry) Hood (qry) Incinerator — Domestic (qty) Incinerator — Comm/ind (qry) Other Mechanical Equipment (qry) Other Mechanical Fee (enter SS) Add' l Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'! Plan Review (hrs) Plan Reviewe Permit Tech: Date: 3 - 0 - 1_ Date: D DEPARTMENTS: Building Division Public Works Approved ❑ vnllOUIL.DOC 3019 PLAN REVIEW /ROUTING SLIP TIVITY NUMBER: M01 -040 PROJECT NAME: SOUTHLAND INDUSTRIES SITE ADDRESS: 13400 INTERURBAN AVE S DATE: 03 -02 -01 SUITE. NO: Response to Incomplete Letter # • Response to Correction Letter # Revision # 1 After Permit Is Issued APPROVALS OR CORRECTIONS: (ten days) Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Incomplete n LEE n Planning Division Permit Coordinator n DUE DATE: 03- -06-01 Not Applicable [7 Comments: TUES /THURS ROUTING: Please Route n Structural Revi w Required n No further Review Required REVIEWER'S INITIALS: El /rn DATE: OA / DUE DATE 04 -03-01 Approved with Conditions ❑ Not Approved (attach comments) C REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions n Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Project Name/Tenant: Guy tancl ys `'t I � � Value of Mechanical E i p2 � t: o s Site Address : C it y State/Zip: j3 �oo " �A,rurla�n we 5 5'�i�wa q���8 Tax Parcel Number: oo0g04-0 iif a q Property Owner: `i t I! � nVea t� /�PM I s Phone: ( 32 � 500 Street Address: Tim 6r., ?$i` III U 5 0 At /war C Stat c1 Fax #: ( 206) 232 t 5g 5 Contractor: � ir�il�riC. S oU�'�'► Phone: ( ) A3....1 742 Street Address: 1 c State/Zia: 00 ter n Ave, . Ti:u ii tai Fax #: ( 206 2 8 �- 1 Contact Person: h550 Phone: (Z ) 283 -- i7 Z Street Address: l 2 i1� - 'e�'ur ian Q� 5, cu rl, City wit c1214? Fax #: (� 4 C 770 •'BUILDING'O NER -.OR•A HORIZED.AGENT: Signature: Date: Z, ` O Print name: / too rawitley Phone: (j )4)23 . i 732 Fax #: (20 ) .1 n Address: ' 0 101f'IIAWLevsi Qlt 5 0 & 181‘8 i iA r „ IN 1'' CITY OF T VWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICALPERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specific): `Toile i @xkAdST 0t% 1'T Haw/. Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. 1 HEREBY CERTIFY THAT ! HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date arinl 'cation accepte)f: Date appli i expires: Applicatii tt n by: (initials) 11/2/99 mach permil.doc of Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 ; .. H.V.A.C. •over 2,000 CFM (approximately,5 ton and larger) must be,provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency . ratings and other applicable'requirements of the.Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal SIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change -out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in ,safe condition.:♦`:. _ NOTE: Water heaters and vents are included in the Uniform Mechanical Code " - please include'any water heaters or vents being installed or replaced. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. i//2/99 miscpmldoc '.ls * * **r*r * **** * * * *a4 * * * * ** 4c..: * * * * * *:i:4 *A. *** * ** * * * * * * * * ** * * ** IT.V OF TUKWILfi WA ` O f • --� . (..J k*.`* * * * *' * ** * * * * : *-* *�4* * : * */a.. *.** * ** * ** * ****"' * *` .** * * * *.* * * * * * *�e�lc,lr * *** ** . ... iR:RNS 4IT t*umher R,- g2-98,...i Amcur t •51'~ 75...03107/.0,,1: 13,:.21 Pavme.rnt •Method : ' .CHEC K No:tat rt,.ri. SOUT Ill: AND . IND.• ] N � y � ri i ;: JT.D Pe rmit .N : .�Mo1 -- 040 ' :Type: B MEC H NIGAL P EF <.�tl.T '. r' h a.c.e1 NC1; 00030001!5 Side Address: 13400 =.1NTE 1LR N AV S Tnta':1 hees . i':.'51'.. .5•":: . Thi Pavmani. `i.. 5 Tot ILL. Pmts 5:1;:. • Balance '. ' . U•0 * * ** * * * * * * *; ************* . * * *. * * * * ** * * *, * *' * * * * * * * * * * * ** :* * * * * * * *.* ** fac�.au`n+ Code r, .Desc riot: inn Amount p.4 0%3:4 . ' 330 •PLANN:. CH .NUANRES 10 35' 000%.322 ° a0 M ECHANICAL .:NllNR x{1.40 '. nature Address: .13400 INTERURBAN AV S S pi t e Tenant: SOUTHLAND.INDUSTRIES '; Tvpei B -MECH. . PaPcel #: 000300 -0115 CITY OF TUKWILA Permit No Status: Applied.: Issued: M01 --040 ISSUED 03/01/2001 03/07/2001 * * *'ik*.* k * * * * ** k * * ** * * * * *•k ** ** k ** k•k * *'*** A k **•k * *•k* A ** k* k ** k** k•A * *: *•k:( * ** *•A * *•k : *A Permit' Conditions: ::Electrical permits shall be obtained through the Washington . Division of. Labor and Industri es, „and all electrical 'work will he Inspected by th:at:agency (248-6630). No changes will be made•- to the plans unless approved by the !Engineer and the la Building Divis ion. ,-; Al i permits, ins =pectian rt records, end approved plans...sha11 be • available: at (tie 1`t�b site'pr��ior' start?of anvs; st ruct i on "6C,rwThese. „documents are to ; be maintained i and avail- able f' f i.na l i nspeeti�'on approval i's granted' Val dity:.df mit. .The..issuancue• of a permit 'or a pia rov,at, of plens44is:pecifications, and,computetions shal nat be 'con strue�'d 't;o. ,b b,e- a permit •ns for .' :dr an approval of, 'any a�r.y rv'io,l,,ation iF of. the provisio `of`',the uilding code or.,. of; any: other; ord the. jurisd- i:cti No permit presuming i ve lituthor,ity •to violate or`cancel ;the provisions: of - 0;i od ,ebe;: =va 1 i d, iereby' bertify, that I have read thes.et con,diti:0ns and wi 11 compl.v th themf ,as o.0 1 i`ned.'' 4 p.ro'v,isi`ons Ofif4 aw- -arid ordinances gove .this <work :will4be, +whether specified herein or ie gran„, ng of '. th'i s permit does no.t, presume to, give author i "ty, t vio,la;te 1 43 can the provisions of any' other work or local laws egulatt construction or the performence. work: z w ft 2 UO w O • w < H ci z w U : O F-' w w; . • O• • z w: O F. COMMENTS: Special instructions: Approved per applicable codes. 0 Corrections required prior to approval. Project: u 61 L( INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 in 0 1 0' O PERMIT NO. (206143.1 -36 Inspector:'" c ! o J Date: 2 r O) $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: LICENSE DETAIL INFORMA,ION Form Page 1 of 1 STATE OF WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES Specialty Compliance Services Division P. O. Box 44000 Olympia, WA 98504 -4000 THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS: LICENSE DETAIL INFORMATION Current Filter: None Registration# or License SOUTHI *044MH Name SOUTHLAND INDUSTRIES Address 17941 FITCH Address City IRVINE State CA Zip 92614 Phone Number 3104248638 Effective Date 7/8/96 Expiration Date 4/1/01 Registration Status ACTIVE Type CONSTRUCTION CONTRACTOR Entity CORPORATION Specialty Code GENERAL Other Specialties UBI Number 601702596 *VIEW PRINCIPAL OWNER(S) FOR THIS LICENSE* * * * "* *VIEW CONTRACTOR BOND /SAVINGS INFORMATION * * * * *CHECK INQUIRY FOR SUMMONS AND COMPLAINTS* * * * * * VIEW CONTRACTOR INSURANCE INFORMATION * * * New inquiry by CITY, NAME, PRINCIPAL OWNER NAME, NUMBER, UBI NUMBER or return to the L &I Construction Compliance Home Page http : / /www.lni.wa.gov / contractors /TF2Form .asp ?License= SOUTHI *044MH 3/7/01 i:•, rV! 0 U 111 : � 1 •, 1':n. <+ 4t+ r.) ,,unrUi U* yAl.bl� U�k''1' Lei U(13 ` 60UTHLAND.INDUSTRIES •.17941 FITCH IRVINE CA 92614' F6 :5,(t .OWO ($97) DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST..# EXP. DATE CCO1` SOUTHI *044MH 04/01/2001 EFFECTIVE DATE 07/08 /1996 SOUTILLAND INDUSTRIES 17941 FITCH IRVINE CA 92614 �-- Detni:l, . DtspI3y C. rt3ticate REGISTERED AS PROVIDED BY LAW A CONST CONT GENERAL REGIST. # EXP. DATE CCO1 .SOUTHI *044MM 04/01/2001 EFFECTIVE DATE . .•.07/08/1996 Siimture - Issucdby DEPARTMENT OF. LABOR AND INDUSTRIES Please Remove And Sign Identification Card Before Placing In Billfold NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. DUCT INSULATION TABLE DUCT USE DUCT LOCATION HEATING DEGREE DAY (HDD) MINIMUM INSULATION (R- VALUE) OVER- BUT NOT OVER- 1 INCH ROOF OR EXTERIOR OF BUILDING 4500 8000 4.2 HEATING ONLY UNCONDITIONED 0 8000 4.2 ROCK, SLAG, OR GLASS SPACE 11 INCH R -5.3 M BER, DUCT BOD, INERA FI ROOF OR 0 ROCK, SL OR GLL ASS 6.3 HEATING AND COOLING EXTERIOR OF BUILDING OR COOLING ONLY UNCONDITIONED SPACE 0 - 4.2 OSA INTERIOR OF BUILDING 0 - 6.3 DUCT INSULATOR R- VALUES TABLE TYPE OF INSULATOR DENSITY (LB /CF) THICKNESS (INCH), INSULATION (R- VALUE) BLANKETS AND FELT, 5" TO 6" 1 INCH R -2.1 MINERAL FIBER. ROCK, SLAG, OR GLASS 0.6 2 INCH 3 INCH R -6.3 R -6.3.. DUCT LINER BLANKETS, 1.5 TO 3.0 ('2 I R -2.1 ROCK, SLAG, OR GLASS 0.5 11 INCH R -5.3 M BER, DUCT BOD, INERA FI %2 INCH R -2.1 ROCK, SL OR GLL ASS 3.0 TO 10 i INCH 11/2 INCH R -4.2 R -6.3 PIPE INSULATION THICKNESS TABLE SYSTEM TEMP. RANGE 1" AND LE 1% TO Y 2 TO 4" 5" TO 6" 8" & UP CONDENSATE DRAIN 40-60 0.5 0.5 1.0 - - CHILLED WATER SUPPLY & RETURN 42 -60 0.5 0.5 1.0 1.0 1.0 LEGEND SYMBOL I ABBREV. DESCRIPTION "(L) LINED DUCT (METOL MEE SHOWN) DUCT UP DUCT DOWN DUCT SECTOR (SUPPLY) - DUCT SECTION (RETURN OR OSA) - DUCT SECTION (EXHAUST) - POINT OF STATIC PRESSURE CIIANGE COL CBUNG DIFFUSER LAY -IN CDS L CBUNG DIFFUSER SURFACE MOUNT - m RR RETURN REGISTER SYMBOL ABBREV. DESCRIPTION PIPE ELBOW TURNED UP PIPE ELBOW TURNED DOWN O 'O' 9 P THERM. STRAINER UNION CONCENTRIC REDUCER (OR INCREASER) ECCENTRIC REDUCER (OR INCREASER) PIPE TEE, BRANCH OUTLET UP PIPE TEE, BRANCH OUTLET DOWN PRESSURE GAUGE THERMOMETER -u -p _ -p - H RG ER Q H'STAT __3f___ D/L f 4/6 - RL - N-- I - �-�-- - RG RETURN GPoUE ER EXHAUST REGISTER EG EXHAUST GRILLE SR SIDEWALL SUPPLY REGISTER SG EDEWALL SUPPLY GRILLE RR SIDEWALL RETURN REGISTER SIDEWALL RETURN GRILLE SIDEWML EXHAUST REGISTER EG SIDEWALL OXHAUST GR11E iG TRANSFER GR. A.D. TSTAT ACCESS DOOR ACCESS PANEL THERMOSTAT HUMIDISTAT DOOR LOUVER (MIN. 50% FREE AREA) DOOR UNDERCUT CHILLED WATER SUPPLY CHWR CHILLED WATER RETURN DRA HEATING NOT WATER SUPPLY HEAD NG HOT WATER RETURN REFRIGERANT SUCTION UNE RL REFRIGERANT UOUID UNE GATE V. GLOBE VALVE CHECK VALVE BALL VALVE BUTTERFLY VALVE BUTTERFLY VALVE, MOTOR OPERATED CONTRA VALVE, ELECTRIC 'TIROL VALVE, PNEUMATIC PLUG VALVE BALANCING VAL F.S D PI GENFRAI NOTES 1. ALL PADS, OPENINGS, CURBS, AND SUPPORTS FOR MECHANICAL EQUIPMENT ARE TO BE COORDINATED WITH APPROVED EQUIPMENT SUBMITTALS PRIOR TO CONSTRUCTION. 2. CEIUNG SUPPLY AND RETURN AIR PLENUMS SHALL BE OF NONCOMBUSTIBLE CONSTRUCTION, SEALED AIRTIGHT, AND CONFORM TO ALL APPLICABLE CODE REQUIREMENTS - BY G.C. 3. ALL EXTERIOR WALL LOUVERS (MINIMUM SOD FREE AREA) AND ASSOCIATED BIRDSCREENS - BY G.C. 4. ALL DOOR LOUVERS (MINIMUM 50% FREE AREA) AND DOOR UNDERCUTS - BY G.C. 5. ACCESS DOORS AND ACCESS PANELS IN WALLS, FLOORS, AND CEIUNGS REQUIRED FOR PROPER ACCESS TO MECHANICAL EQUIPMENT ARE TO BE FIELD LOCATED DURING THE SHOP DRAWING PHASE AND ARE TO BE FURNISHED AND INSTALLED - BY G.C. 6. CONDENSATE DRAINS ARE TO BE TRAPPED AND PITCHED NOT LESS THAN (4 INCH PER FOOT TO NEAREST APPROVED RECEPTOR. 7. COORDINATE LOCATION OF ALL THERMOSTATS WITH OWNER PRIOR TO INSTALLATION. ALL THERMOSTATS MOUNTED ON EXTERIOR WALLS ARE TO HAVE INSULATED BACKS. 8. WHEN A COOLING COIL OR COOUNG UNIT IS LOCATED IN AN ATTIC OR FURRED SPACE WHERE DAMAGE MAY RESULT FROM CONDENSATE OVERFLOW, AN ADDITIONAL WATERTIGHT PAN OF CORROSION - RESISTANT METAL SHALL BE INSTALLED BENEATH THE COOUNG COIL OR UNIT BOTTOM TO CATCH THE OVERFLOW CONDENSATE DUE TO A CLOGGED PRIMARY CONDENSATE DRAIN, OR ONE PAN WITH A STANDING OVERFLOW AND A SEPARATE SECONDARY DRAIN MAY BE PROVIDED IN LIEU OF THE SECONDARY DRAIN PAN. THE ADDITIONAL PAN OR THE STANDING OVERFLOW SHALL BE PROVIDED WITH A DRAIN PIPE, MINIMUM 3/4 -INCH NOMINAL PIPE SIZE, DISCHARGING AT A POINT WHICH CAN BE READILY OBSERVED. 9. ALL DUCTWORK SHALL BE SUPPORTED AND BRACED IN ACCORDANCE W/ SMACNA GUIDELINES FOR SEISMIC RESTRAINTS FOR MECHANICAL SYSTEMS. 10. THE ANCHORAGE AND /OR SEISMIC RESTRAINT OF PERMANENT EQUIPMENT AND_ ASSOCIATED SYSTEMS SHALL BE DESIGNED TO RESIST THE TOTAL DESIGN SEISMIC FORCES PRESCRIBED IN SECTION 1632.2 OF THE UNIFORM BUILDING CODE. AA' FLEX CONN. RMSURE RELIEF VALVE PRESSURE REDUCING VALVE SOLENOID VALVE AUTOMATIC AR VENT PE1FS PLUG TAM SWITCH (DIFF. PR65UIHE TYPE) CAP BANGED JOINT GROOVED JOINT 5.606E CONNECTION (MEALLIC) --- '' SAL CONK. FLEXIBLE CONNECTION (NEOPRENE) MOTOR LOCATOR R. TEMPERATURE SENSOR DIFFERENTIAL PRESSURE TRANSMITTER PRESSURE INDICATOR TEMPERATURE INDICATOR ONE DETECTOR ELECTRICAL INTERLOCK N CONTROL NR SUPPLY DUCT INSUI ANION 3. ABBREV DESCRIPTION AB, ABOVE A.F.F. ABOVE FINISHED FLOOR A.D. ACCESS DOOR A.P. ACCESS PANEL AC. OR A/C AIR CONDITIONING A.F.S. AIR FLOW STATION AHU AIR HANDLING UNIT AS AIR SEPARATOR AIB. AMBIENT AMPS AMPERES Ar ARGON ATM. ATMOSPHERE, ATMOSPHERIC A.A.V. AUTOMATIC AIR VENT B.D.D. B.F. 6.0.D. B.O.P. BHP BTU BTUH BLDG. B.A.S. CAP. CLG. CDL CDS CHW CDA C.O.P. CONC. COND. CD, C.D. CW CFM OR D 'F DI D.P. D.D.C. DCW D/L DN. DR. DWG. DB EFF. ECG EDH E.C. E.E.R. EAT EWT ECW EVAP. EA EG ER (E) or E E.S.P. Fi. FPM FRP F.D. F /S.D. FLT. F.S. FLA FE (F) or F NOTES BACKDRAFT DAMPER BOTTOM FLAT, BLIND FLANGE BOTTOM OF DUCT BOTTOM OF PIPE BRAKE HORSEPOWER BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR BUILDING BUILDING AUTOMATON SYSTEM CAPACITY CEILING CEILING DIFFUSER LAY -IN CEILING DIFFUSER SURFACE MOUNT CHILLED WATER CLEAN DRY AIR COEFFICIENT OF PERFORMANCE CONCRETE CONDENSATE (STEAM) CEIUNG DIFFUSER, COND. DRAIN CONDENSER WATER CUBIC FEET PER MINUTE DEGREE FAHRENHEIT DEIONIZED WATER DIFFERENTIAL PRESSURE DIRECT DIGITAL CONTROL DOMESTIC (POTABLE) COLD WATER DOOR LOUVER DOWN DRAIN DRAWING DRY BULB TEMPERATURE EFFICIENCY EGGCRATE GRILLE ELECTRIC DUCT HEATER ELECTRICAL CONTRACTOR ENERGY EFFICIENCY. RATIO ENTERING AIR TEMPERTURE ENTERING WATER TEMPERATUE EQUIPMENT COOUNG WATER EVAPORATIVE EXHAUST AIR EXHAUST GRILLE EXHAUST REGISTER EXISTING EXTERNAL STATIC PRESSURE FEET FEET PER MINUTE FIBERGLASS REINFORCED PLASTIC FIRE DAMPER FIRE /SMOKE DAMPER FLOOR FLOOR SINK FULL LOAD AMPS FUME EXHAUST FUTURE 1. DUCTWORK IN AN UNCONDITIONED SPACE OR EXPOSED TO OUTSIDE AIR AND ALL OUTSIDE AIR DUCTWORK REQUIRE INSULATION ACCORDING TO THE "DUCT INSULATION TABLE AND THE "DUCT INSULATION R- VALUES TABLE BELOW. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR A FLOOR - CEIUNG SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. THIS EXCEPTION DOES NOT APPLY TO OUTSIDE AIR DUCTWORK., IF THE INSULATOR IS. EXPOSED TO OUTDOOR CLIMATE, THE INSULATION REQUIRES AN APPROVED WEATHERPROOF BARRIER TO PROTECT IT FROM DEGRADATION. 4. IF THE INSULATOR IS FOR DUCTWORK THAT SUPPUES MECHANICALLY COOLED AIR, THE INSULATION REQUIRES A VAPOR BARRIER ON THE WARM SIDE OF THE INSULATION TO PROTECT IT FROM CONDENSATION. THE VAPOR' BARRIER SHALL BE CONTINUOUS, WITH ALL JOINTS SEALED, AND HAVE A RATING OF 0.5 PERM. 5. IF THE INSULATOR IS FOR OUTSIDE AIR DUCTWORK, THE INSULATION REQUIRES A VAPOR BARRIER TO PROTECT I4 FROM CONDENSATION. THE VAPOR BARRIER SHALL BE CONTINUOUS, WITH ALL JOINTS SEALED, AND HAVE A RATING OF 0.5 PERM. ABBREV. GPH GPM G.V. G.C. HX HTG. HW HVAC HP HV H'STAT H2 IN. I.D. KV KVA KW LAT LWT (L) LN 2 L. LBS. MAU M.A.V. M.C. MA M.D. MTD. MBH NPSH N (N) or 2 NPW N.C. N.O. N.I.C. N.T.S. O.C. OBD OSA O.D. 02 PH' P.C. P.O.C. PPP PVC PVDF PSI PRESS. DP PCV P.G. P.R.S. P.R.V. PCHW PV RAU REFRIO. RHC RH (R) ABBREVIATIONS GALLONS PER HOUR GALLONS PER MINUTE GATE VALVE GENERAL CONTRACTOR KILOVOLTS KILOVOLT AMPERES KILOWATTS DESCRIPTION HEAT EXCHANGER HEATING HEATING HOT WATER HEATING, VENTILATING. AND AIR CONDITIONING HORSEPOWER HOUSEKEEPING VACUUM HUMIDISTAT HYDROGEN GAS NC INSIDE HES DIAMETER OR DIMENSION LEAVING A)R TEMPERATURE LEAVING WATER TEMPERATURE LINED LIQUID NITROGEN LOCKED ROTOR AMPS POUNDS MAKEUP AIR UNIT MANUAL AIR VENT MECHANICAL CONTRACTOR MIXED AIR MOTORIZED VOLUME DAMP /A MOUNTED THOUSAND BTUH NET POSITIVE SUCTION HEAD NEW NITROGEN GAS NON - POTABLE WATER NORMALLY CLOSED NORMALLY OPEN NOT IN CONTRACT NOT TO SCALE ON CENTER OPPOSED BLADE DAMPER OUTSIDE AIR OUTSIDE DIAMETER OR DIMENSION OXYGEN GAS PHASE PLUMBING CONTRACTOR POINT OF CONNECTION POLYPROPYLENE PIPE POLYVINYL CHLORIDE '.. POLYVINYUDENE FLUORIDE POUNDS PER SQUARE INCH PRESSURE. PRESSURE CHANGE PRESSURE CONTROL VALVE - PRESSUREGAGE PRESSURE REDUCING STATION PRESSURE REDUCING'. VALVE PRIMARY CHILLED WATER PROCESS VACUUM RECIRCULATION AIR UNIT REFRIGERANT REHEAT COIL RELATIVE HUMIDITY RELOCATED ABBREV. READ RA RG RR RO RPM RM. RLA SC SCHW SHT. SD. S.D. SCRUBBER SECONDARY CHILLED WATER SHEET SMOKE DETECTOR, SMOKE DAMPER S/S STAINLESS STEEL S.P. STATIC PRESSURE STM STEAM SA SUPPLY AIR SG SUPPLY GRILLE SR SUPPLY REGISTER TU THERM. T'STAT T.F. TDH T.P. T.S.P. TG TAP. U/C U.N.O. U.T.R. V.D. VAV V WB W W/O DESCRIPTOR REQUIRED RETURN AIR RETURN GRILLE RETURN REGISTER REVERSE OSMOSIS REVOLUTIONS PER MINUTE ROOM RUNNING LOAD AMPS TERMINAL UNIT _ THERMOMETER THERMOSTAT TOP FLAT TOTAL DYNAMIC HEAD TOTAL PRESSURE TOTAL STATIC PRESSURE TRANSFER GRILLE TYPICAL UNDERCUT UNLESS NOTED OTHERWISE UP THRU ROOF MANUAL VOLUME DAMPER VARIABLE AIR VOLUME VOLTS WATTS WET BULB TEMPERATURE WITH WITHOUT PIPE INSULATION 1. PIPING SERVING A HEATING AND COOUNG SYSTEM REQUIRES INSULATOR ACCORDING TO THE "PIPE INSULATION TABLE" BELOW. 2. INSULATION THICKNESSES IN THE "PIPE INSULATION TABLE ARE BASED ON A THERMAL RESISTANCE (R) OF 4.0 TO 4.6 PER INCH OF THICKNESS ON A FLAT SURFACE AT A MEAN TEMPERATURE OF 75 T. 3. FOR INSULATION GREATER THAN R -4.6 PER INCH, FIGURE THE MINIMUM THICKNESS BY 4.6 x TABLE THICKNESS ACTUAL R -VALUE 4. FOR INSULATOR LESS THAN R -4.0 PER INCH, FIGURE THE MINIMUM THICKNESS BY: 4.0 x TABLE THICKNESS ACTUAL R -VALUE 5. WHERE REQUIRED TO PREVENT CONDENSATION, INSTALL A VAPOR BARRIER ON THE WARM SIDE OF THE INSULATION. PROVIDE PIPE INSULATION IN ACCORDANCE WITH THE TABLE BELOW: MO1-040 4. VELOCITIES A. DUCT WORK M2.1 HVAC FLOOR PLAN PERFORMANCE CRITERIA i. INTENT A. THE INTENT OF THIS PERFORMANCE CRITERIA IS TO DEFINE THE LEVEL OF PERFORMANCE THAT WILL BE PROVIDED BY THE COMPLETED HVAC SYSTEM AND TO DESCRIBE THE BASIC PARAMETERS USED IN THE DESIGN TO ENSURE THAT LEVEL OF PERFORMANCE. 2. CODES AND STANDARDS A. ALL ENGINEERING CALCULATIONS WILL BE BASED ON THE LATEST RECOMMENDATIONS OF ASHRAE AND WILL BE SUPERVISED BY A TA COIM TE OF WA OF W SHINGTON. MECHANICAL ENGINEER DULY LICENSED IN THE S B. THE DESIGN WILL CONFORM TO THE REQUIREMENTS OF THE 1997 UNF IORM BUIDING CODE, THE 1997 UNIFORM MECHANICAL SODS AN D STATE FIR MARSHALL AND ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES. 3. DESIGN CRITERIA A. HVAC DRY SIDE OUTSIDE SUMMER DESIGN 85'F OB / 65'F WB OUTSIDE WINTER DESIGN 23'F DB B. INSIDE DESIGN 72'F SUMMER AND WINTER MAXIMUM OF 0.08 IN. WC / 100 FT. PRESSURE DROP MO.1 LEGEND, NOTES AND DESIGN CRITERIA FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adapted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. n A BR `-.". _ Date IA1, 7.-.0 II permit No. _..6 REVISIONS CITES SHALL BE MA TO W ITHOUT �P7 0: TUIU5.ILA BUI LDING DIV; NAL PKAN R SEPARATE PERMIT REQUIRED FOR: ❑ ¢7ECHANICAL E LECTRICAL ❑ PLUMBING ❑ GAS PIPING CITY OF TUOTAILA BUILDING DIVISION ti DATE SCALE DRAWN BY DESIGNED BY I PP CHECKED. BY JOB NO. 10/24/00 NONE JB PP 7911618 SOUTHLAND INDUSTRIES NMI E AST r STREET LONG BEA CALIFORNIA BDeoT TEL 15621424 -8638 FAX 15621490 -0767 DRAWIN MARIIZ MitY.TEA NOTFS: iQ NEW 12 "0 EXHAUST DUCTWORK UP TO SECOND FLOOR. CENTRIFUGAL EXHAUST FAN (EF -2). WO EN'S EN'S BREAK 0 O -r FQUIPMFNT TOILET EXHAUST FAN EF -2: SUPPLY REGISTERS: STEEL REGISTER, DUCT MOUNTED WITH OPPOSED BLADE DAMPER, TONS MODEL 301 RL OR EQUAL, SIZED AS FOLLOWS: pA 10" X 6" 08. 12" X. 6" © 12" X 8" EXHAUST GRILLES: STEEL, CEILING MOUNTED GRILLE, TITUS MODEL 350 RL OR EQUAL, W /OPTIONAL 24 "x24 "LAY -IN PANEL SIZED AS FOLLOWS: (iD 10" X 10" RETURN GRILLES AND STEEL WALL MOUNTED GRILLES, TRANSFER GRILLES: TITUS MODEL 350 RL OR EQUAL, SIZED AS FOLLOWS: 8 "X8" 10" X 10" 12" X 12" 14 "X 14" 18" x 14" 36" x 36" 680 CFM N 1/2" TSP., 0.19BHP 1/4 HP MOTOR, 115 VOLT, 10, 60HZ GREENHECK MODEL NO. GB -080 -4 WITH BACK DRAFT DAMPER, BIRDSCREEN AND ROOF CURB. MO1-040 J a SOUTHLAND INDUSTRIES 1661 EAST 3710 STREET LONG BEACH, CALIFORNIA 90807 TEL 1562) 424 -8638 FAX 1562) 490 -0767 DRAWING0��' - '� RECEIVED CRY OF TUKWILA DATE 02/20/01 SCALE %g " =1.- W BY JSK DESIGNED CY PP CHECKED BY PP JOB NO. 7911618 DRAWN , M2 2 :0 PERMRCENTER OF 3 SHEETS i NOTES' 10 CONNECT TO EXISTING 20" X 20" SUPPLY DUCT FROM 5 TON ROOF TOP PACKAGED UNIT ON ROOF. 02 CONNECT TO EXISTING 20" X 20" RETURN DUCT FROM 5 TON ROOF TOP PACKAGED UNIT ON ROOF AND EXTEND 20" X 20" (1" UNED) WITH ELBOW TO SIDE WALL RETURN GRILLE. 30 CONNECT TO EXISTING 20" X 20" SUPPLY DUCT FROM 5 TON ROOF TOP PACKAGED UNIT ON ROOF AND EXTEND 20" X 20" (1" LINED) WITH ELBOW TO SUPPLY BRANCHES. O CONNECT TO EXISTING 20" X 20" RETURN DUCT FROM 5 TON ROOF TOP PACKAGED UNIT ON ROOF AND EXTEND 20" X 20" (1" LINED) WITH ELBOW TO SIDE WALL RETURN GRILLE. 50 CONNECT TO EXISTING 20" X 20" SUPPLY DUCT FROM 5 TON ROOF TOP PACKAGED UNIT ON ROOF. © CONNECT TO EXISTING 20" X 20" RETURN DUCT FROM 5 TON ROOF TOP PACKAGED UNIT ON ROOF AND EXTEND 20" X 20" (1" LINED) WITH ELBOW TO SIDE WALL RETURN GRILLE. CONNECT NEW EXHAUST DUCTWORK TO EXISTING 10" X 10" DUCTWORK STUBBED UP THRU ROOF. PROVIDE A NEW ROOF TOP CENTRIFUGAL EXHAUST FAN (EF -1). NEW 12 "0 EXHAUST DUCT FROM FIRST FLOOR. R R2.)N NEW IZ 6ct4A'u5T WO TttK11 (too( usro1C7 EXISTbK gooF ovEMi#IC7.1 Nevi 12DOF-roP Fei NI LWF . RETURN GRILLES AND TRANSFER GRILLES: CO O O FQUIPMFNT TOILET EXHAUST FAN EF -1: 620 CFM IN 1/2" TSP. 1/4 HP MOTOR, 120 VOLT, 10, 60HZ GREENHECK MODEL NO. GB -10 -4 WITH BACK DRAFT DAMPER, BIRDSCREEN AND ROOF CURB. SUPPLY REGISTERS: STEEL REGISTER, DUCT MOUNTED WITH OPPOSED'. BLADE DAMPER, DTUS MODEL 301 RL OR EQUAL, SIZED AS FOLLOWS: EXHAUST GRILLES: DA, 10" X 6" O 12" X 6" © 12" X 8" STEEL, CEIUNG MOUNTED GRILLE, TITUS MODEL 350 RL OR EQUAL, SIZED AS FOLLOWS: O 10° X' 10 " STEEL, WALL MOUNTED GRILLES, TITUS MODEL 350 RL OR EQUAL, SIZED AS FOLLOWS: 8 ° X 8 10" X 10 12" X 12 14 "X 14" 18" x 14" 36" x 36" HVAC FLOOR PLAN TvlO 1-040 CRAM NAR PERMRCE z 0 N N DATE SCALE DRAWN BY DESIGNED EY CHECKED BY JOB NO: JB PP PP 7911618 10/24/00 cti I SOUTHLAND INDUSTRIES 1661 E ATf 33ND STREET LONO BEACH, CALIFORNIA 90807 TEL 1562)424 - 8638 FAX 15,62)490 -0767 DRAWING NO Ll M2.1 OF 2 SHEETS