Loading...
HomeMy WebLinkAboutPermit M01-048 - BATH AND BODY WORKS7332 uthcenter Py City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M01 -048 Type: B -MECH Category: Address: 17332 SOUTHCENTER PY Location: Parcel #: 262304 -9079 Contractor License No: TENANT BATH AND BODY WORKS Phone: 17332 SOUTHCENTER PY. TUKWILA WA 98188 OWNER MBK NORTHWEST Phone: 206 575 -8090 C/O TRAMMEL CROW COMPANY, 17560 SOUTHCENTER PY, TUKWILA WA 98188 CONTACT TIM SCHENK Phone: 800- 541 -0821 1120 E 80 ST SUITE 211, BLOOMINGTON MN 55420 ********************************************* * * * * * * * * * * * ** * * * * * * * * * * * * * *•k ** Permit Description: INSTALL TWO NEW VAV BOXES. DUCTWORK, DIFFUSERS, GRILLES. AND NEW CONTROLS. UMC Edition: 1997 * * * * * * * * * * *. * * ** * ** Print Name: t Center Auth•rized Signatur MECHANICAL PERMIT Valuation: .00 Total Permit Fee: 59.81 ************** ** * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Date y�Z� -- (206) 431 -3670 Status: ISSUED Issued: 04/25/2001 Expires: 10/22/2001 ereby certify t at .I have read` and examined this permit and know the same tobe true and correct. Al provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. .I am authorized to sign for and obtain this bui ding pe it. Signature: tdagi Date: (1-, 5. G Title: ?op ASCitat This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. z rq 0 0: . c 0 O LL. W 0 J Ii a O 1 1:2' ; ' - 0 • 0 1_' w W. Z . 1— ---. I A O' • ui Z UN. 0 • Z • Revision • No.. Date Received Staff Initials Date Issued ''Staff Initials S -L3 -v — n 6- /�ist e Summary of Revision: _,,,,� ,�;,. _ 7' ∎ // Received By: ' J E FF c.D v1 Revision No. I Date I Received Date Received Date l Staff Issued I Initials Staff I Initials Date Issued ` Staff I •. -: Initials 2. 1 1 51-5 of I 1 I ( —t-b/ I & Summary of Revision: /ldp ou Ca( 0.2_ Received By: Received By `SQ.F F .5c,h e-w 2 v . Revision No. ' '. I Date I Received Staff Initials Date l Staff Issued I Initials 1 —... 1 I Summary of Revision: I Staff Initials Received By: Summary of Revision: I Summary of Revision: • Received By: Revision No. Date . Received I Staff I Date Initials Issued Staff Initials 1 —... 1 I Summary of Revision: I Staff Initials Received By: av4 k 130 6� ,oYk*7 '" PROJECT NAME: 61 1- 4 PERM►NO 0 0 e Site Address: l 3 i 2- S i.ea,. c V •• Original Issue Date: REVISION LOG (please print) (please print) please print) p dut11A LIMI iiAJt w1k1GJ. aJ+ hJ3� ?h�N�YGJik�itq;�yyd+,.\y4**i> - r�++�M\n:YW.lb'n'� ✓. L' • z U O N0 : v) w, N � w 2 J u. �. w_ zI zo w uj o U O 01— w ul H I . u_ I ui co O Revision No. Date Staff Date Received I Initials I - Issued I Staff Initials 1 I I I Summary of Revision: Received By: av4 k 130 6� ,oYk*7 '" PROJECT NAME: 61 1- 4 PERM►NO 0 0 e Site Address: l 3 i 2- S i.ea,. c V •• Original Issue Date: REVISION LOG (please print) (please print) please print) p dut11A LIMI iiAJt w1k1GJ. aJ+ hJ3� ?h�N�YGJik�itq;�yyd+,.\y4**i> - r�++�M\n:YW.lb'n'� ✓. L' • z U O N0 : v) w, N � w 2 J u. �. w_ zI zo w uj o U O 01— w ul H I . u_ I ui co O A CTIVITY NUMBER M01 -048 DATE: 05 -23 -01 PROJECT NAME: BATH AND BODY WORKS SITE ADDRESS: 17332 SOUTHCENTER PKWY SUITE NO: Complete Comments: VIIROUlt.DOC PLAN REVIEW /ROUTING SLIP Original Plan Submittal Response to Correction Letter DEPARTMENTS: BuildlnDivision Public Wor s TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: Fire Prevention s - Z3`°f Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Structural Review Required APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions n Response to Incomplete Letter # ; gev�sion # 2 AFTER Permit Is Issued 11 n Planning Division Permit Coordinator DUE DATE: 05 -24 -01 Not Applicable No further Review Required DATE: DUE DATE 06-21 -01 n n n Not Approved (attach comments) REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions n Not Approved (attach comments) REVIEWER'S INITIALS: DATE: PERMIT COORD COPY Entered in Sierra on Date: JPi/D f ❑ Response to Incomplete Letter # 0 Response to Correction Letter # Revision # -after Permit is Issued City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Project Name: Bc' 4 W 4 &c (-t/c9 r- k 3 Project Address: 1 7 33:1 5o fic,. rl7c e;c( Contact Person: S Fr .5c-he 41 Phone Number: 2 o G ~ `1023 — 5353 Summary of Revision: ( occ, 1 Ce c 2- Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Plan Check/Permit Number: (- DEPARTMENTS: Building Division Public Works Complete Comments: REVIEWER'S INITIALS: Approved REVIEWER'S INITIALS: v'RRODU.VOC srri PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER M01 -048 DATE: 05 -23 -01 PROJECT NAME:. BATH AND BODY WORKS SITE ADDRESS: 17332 SOUTHCENTER PKWY SUITE NO: Original ;Plan Submittal Response to. Incomplete Letter # Response to Correction Letter # Revision # 2 AFTER Permit Is Issued PI CORRECTION DETERMINATION: APPROVALS OR CfJRRECTIONS: (ten days) Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n n Planning Division Permit Coordinator Not Applicable TUES /THURS ROUTING: Please Route n Structural ' w Required n No further Review Required DUE DATE 06 -21 -01 Approved w . itions n Not Approved (attach comments) DUE DATE: 05-24-01 DATE: 5 -24- ZOO 11 DATE: 5- 24-200 DUE DATE Approved n Approved with Conditions' 1 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: SOcaourt.00c SOB ACTIVITY NUMBER M01 -048 DATE: 05 -23 -01 PROJECT NAME: BATH AND BODY WORKS SITE ADDRESS: 17332 SOUTHCENTER PKWY SUITE NO: Response to Incomplete Letter # Response to Correction Letter # Revision # 2 AFTER Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: PLAN REVIEW /ROUTING SLIP n REVIEWER'S INITIALS: Fire Prevention Structural TUES /THURS ROUTING: Please Route n Structural Review Required Incomplete n Not Applicable APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions REVIEWER'S INITIALS: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions l Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Planning Division Permit Coordinator No further Review Required DATE: S /0/ n DUE DATE: 05 -24 -01 DUE DATE 06-21 -01 Not Approved (attach comments) n DATE: Y.1TW;M.hfiYhtL Veut'aA•t ?• i.�dlaisr:FN vai +F': ?;Yfti 1 DEPARTMENTS: g Division q'v -o Public Works TUES /THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete F Incomplete n APPROVALS OR CORRECTIONS: (ten days) Fire �P Structural REVIEWER'S INITIALS: V'14 OUII.DOC SPPI PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER M01 -048 DATE: 05 -18 -01 PROJECT NAME: BATH AND BODY WORKS SITE ADDRESS: 17332 SOUTHCENTER PY SUITE NO Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # . 1 AFTER Permit Is Issued Planning Division Permit Coordinator No further Review Required DUE DATE 06 -19-01 Approved 1111 Approved with Conditions n Not Approved (attach comments) DUE DATE: 05 -22-01 Not Applicable U Comments: DATE: DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: re f . S : CO 9 w 1 Z � w uj gyp; O N 0 I- w ui U „ Z w co O Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date:.5/ l g f Q 0 Response to Incomplete Letter # 0 Response to Correction Letter # Revision # f after Permit is Issued Project Name: (3Cr t--h i- 80d (. r 6t Project Address: 173 3 v2. 500P c-an -ad Pe--/"" w,¢. Contact Person: F - Q� Phone Number: y 'Z -'(23 53,f ` C e Summary of Revision: 02O 6- Sr ' — 3 /-5 S e '-e Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ti' [y Entered in Sierra on ` I '--oi L - City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Plan Check/Permit Number: .01 -0 RECEIVED CITY OF TUKWILA MAY 1 8 2001 PEKMI I l,tN I tK 08/30/00 ACTIVITY NUMBER M01 - 048 PROJECT NAME: BATH AND BODY WORKS SITE ADDRESS: 17332 SOUTHCENTER PY SUITE NO: Original Plan Submittal Response to Correction Letter # DATE: 05 -18 -01 Response to Incomplete Letter # X Revision # 1 AFTER Permit Is Issued DEPARTMENTS: Building Division Public Works PLAN REVIEW /ROUTING SLIP Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Commen s: 61. APPROVALS OR CORRECTIONS: (ten days) Fire Prevention Approved n Approved ith Conditions th REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved n Approved with Conditions REVIEWER'S INITIALS: v'Rzomt.DOC n Permit Coordinator DUE DATE: 05-22 -01 Not Applicable L 4- TUES /THURS ROUTING: Please Route n Structural Re • w Required No further Review Requirgd REVIEWER'S INITIALS: DATE: qg DUE DATE 06 -19 -01 Not Approved (attac co ments) DATE: Planning Division n DUE DATE Not Approved (attach comments) DATE: re 2 iLl U'. 0 : V) 0 �n uJ w 0 u_ — 0 z � I- 0 Z �. ui V 0 i 0N l 0 1- w Lu U : LL H O .. z vN O z_..._ o'") PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER M01 -048 DATE: 05 -18 -01 PROJECT NAME: BATH AND BODY WORKS SITE ADDRESS: 17332 SOUTHCENTER PY SUITE NO: Original'. Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 AFTER Permit Is Issued DEPARTMENTS: Building Division Public Works ❑ Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Incomplete n Comments: TUES /THURS ROUTING: Please Route ❑ Structural Review Required REVIEWER'S INITIALS: /4 /ft1 APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved n Approved with Conditions REVIEWER'S INITIALS: NRROUII.IOC 5144 d i Planning Division F - 1 Permit Coordinator n DUE DATE: 05-22-01 Not Applicable n No further Review Required DATE: � /01 DUE DATE 06 -19 -01 Not Approved (attach comments) DATE: DUE DATE Not Approved (attach comments) DATE: DEPARTMENTS: Build 'vision e 4 - 1a'D( Public Works WK OUtL.DOC SPry REVIEWER'S INITIALS: i e PreLntion Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete I . I Incomplete Comments: CORRECTION DETERMINATION: Approved 1 1 Approved with Conditions PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M01 -048 DATE: 3 -16 -01 PROJECT NAME: BATH & BODY WORKS SITE ADDRESS: 17332 SOUTHCENTER PY SUITE NO: Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued Planning Division Permit Coordinator DUE DATE: 3 -20 -2001 Not Applicable n • TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE 447-2001 Approved ❑ Approved with Conditions' Not Approved (attach comments) REVIEWER'S INITIALS: DATE: DUE DATE Not Approved (attach comments) DATE: A NUMBER: M01-048 DATE: 3-16-01 PROJECT NAME: BATH & BODY WORKS SITE ADDRESS: 17332 SOUTHCENTER PY SUITE NO: Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued • DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: PLAN REVIEW/ROUTING SLIP Incomplete -.1 a=t■.A.051.Y'e- c;;„\ TUES/THURS ROUTI NG: Please Route Structural Review Re REVIEWER'S INITIALS: Structural APPROVALS OR CORRECTIONS: (ten days) Approved fl REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved fl YltROUII.IX)C S199 Fire Prevention Not Applicable ri JAee3 -4 Approved with Conditions n n Planning Division Permit Coordinator n DUE DATE: 3-20-2001 No further Review Required DATE: 3-Z4o-zoo( DUE DATE 4-17-2001 1 Not Approved (atta h co ments) I DATE: 4 IA 6( DUE DATE Approved with Conditions Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: ' . ' PERMIT NO.: MECHANICAL PERMIT APPLICATIONS INSPECTIONS D1 ❑ 00002 Pre - construction ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation /Indoor AQC ❑ 00610 Chimney Installation /All Types ❑ 00700 Framing ❑ 01080 Woodstove ❑ 01090 Smoke Detector Shut Off 01100 Rough -in Mechanical 01101 Mechanical Equipment/Controls ❑ 01102 Mechanical Pip /Duct Insul ❑ 01105 Underground Mech Rough -in O 01115 Motor Inspection 1400 Fire Final :� 01800 Final Mechanical ❑ 04015 Special -Smoke Control System CONDITIONS 0001 No changes to plans unless approved by Bldg Div ❑ 0014 Readily accessible access to roof mounted equipment 0016 Exposed insulation backing material 0019 All construction to be done in conformance w /approved plans ❑ 0002 Plumbing permits shall be obtained through King Co • 0027 Validity of Permit 0003 Electrical permits obtained through L & I ❑ 0036 Manufacturers installation instructions required on site ❑ "BTU maximum allowed per 1997 WA State Energy Code" ❑ 0041 Ventilation is required for all new rooms & spaces 0005 All permits, insp records & approved plans available ❑ "Fuel burning appliances ❑ "Appliances, which generate...." ❑ "Water heater shall be anchored...." Additional Conditions: TENANT NAME1 y (-oar' FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace /Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended /Wall /Floor - mounted Heater (qty) Appliance Vent (qty) Heating /Refrig /Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Coinm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) Add'1 Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'l Plan Review (hrs) Plan Reviewed mil. Permit Tech: Date: Date: 4'l(t 0( • ACTIVITY NUMBER: M01 -048 DATE: 3 -16 -01 PROJECT NAME: BATH &' WORKS SITE ADDRESS: 17332 SOUTHCENTER PY SUITE NO: Original. Plan Submittal Response to. Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works Complete El Comments: TUES /THURS ROUTING: PLAN REVIEW /ROUTING SLIP n n Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Please Route Structural Review Required APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions REVIEWER'S INITIALS: uKRO WC.DOC �ro n REVIEWER'S INITIALS: •< Planning Division Permit Coordinator Not Applicable No further Review Required DATE: 3-- - 01 n DUE DATE: 3-20-2001 DUE DATE 4 -17 -2001 Not Approved (attach comments) DATE: CORRECTION DETERMINATION: DUE DATE Approved Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: z CI 2 00 co uk w 2 u-< to w uj V O ON w w . lb Z U co O ff"', z Project Name/Tenant: 'Stmt.' + 600•{ Woltles L ep is -4A''( SveE(LCerceR - . Value of Mechanical Equipment: Site Address : City State/Zi • 1 SOO1n4c- er.ItEl2. aa- tc WW1 . 1 WA • 9 8f86• , Tax Parcel�Ntumber: SG/23b Lt--4079 Phone: ( ) 673 - 636. 2Eico • Property Owner: tv■ rs►c. /40( n— wES r . Street Address: City State/Zip: 9 4 a i • s . W . MEAww , . Wire 6 • wee OSWC60 of. 41:73 .7 Fax #: ( ) Contractor: (30,11 iMit0 Phone: ( ) Street Address: City State/Zip: Fax #: ( ) Contact Person: "TIM SC.► -0.44. e. e_t_oZ(L- JvrIE3 , 1 Phone: ( ) 1.300 •S41.0VA Street Address: a City State/Zip: i X20 E • 80 sr. sv ire z1 i . &Qom i rro rrirJ 1✓ r4 S'St z0 Fax #: ( ) 952 • c554 .490 . BUILDING'OWNER.OR AUTHORIZED AGENT: ; Signature: L Date: s 14 Q 1 Print name :n m s c . . 4 P h o n e : ( $03 ) ' o'62.1 Fax #: ( ei ,2 Wi•4909 Address: }t, t a0 E • - sr. sV 1TE u 1 City /State/Zip: . AL.onrnt,46rOnl mni CS4 CITY OF T 'KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. 'MECHANICAL PERMIT.REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specific): 1nl SrALL TW 0C 2 ) NE ts/ VAIN noxES, OJCT'WO/LIG , l= t1SOZS G2tLLE5 Ar40 EI.1 03r4TYLOLS Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SA ME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LA WS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: 1.' i ». ( Application taken by: (initials) 11/2199 meth permli.doc STAR- USE ONLY Project Number. Permit Number. ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C, over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal SIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat Toss calculations or Form H -6. Equipment specifications. Change -out or replacement of existing mechanical equipment Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. 1 1/2/99 n,isciinadoc NOTE: •Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. • CITY OF TUKWILA ; dcir`es i'.71.3.2 SOOTHCENTER PY Permit: Nix: MO1 -048 Suite:., :T'e.nant: PATH ANO BODY WORE: Status: I_,:;UED TVpe i 8 -MECH . Atop 1 i et1: 03/1612002 ar c e 1: #: 262304 -507!? . 0.4.125/2001 . .•h k.�4 •k •k 7r h.'k k k •k 'k •k '1. * •k •k••k 1. 'k 'k 'k 4• * •k •k k k k •.k �k k •k 'k Ak •k 'k •k 'k ±4 • k. ;k *• 'k k •t •k •k •1. * -k k k •k 'k • , ' k •.l k -k k •k :a •k k •fi k *k * k •k Ak •k k . • t. Condition.: • ~,:1 Anv er�iosed in'aufigtic?ns back inu:material _.ha11 have a .Fiame Sp read ,fiat in Of 25 car le ari mater ia1 shall b>rar• ident - ficat.i sliuw:ina t,h,e t�ri, e iier•fi...ir thereof. El ectrical termitS :tta`ll beobtai,ned • Chrou+ih► .t WL h ington Stt at e 0,,1 loci at " °Lahc�r and Indu,kr-fes and' i1 ,:':.let;tri wur F, will be; uriSUl ?t yeti =` by that ;v t 4C- 46301; ?': 3 No a;hatlde..3 r�i'11 b ;'.maife 'to the :a1an': uril'e: aour'ovz'd by the y a_ �' � f i t ? ., En ginet:f i ci the l'uI wi a Eiu1 1•ding, inn ; 4 Ali 1et^m >i . ,4 si r �ciec t i orl r e Os sand apt:T6ve r.4ij'a9 };she+ ! I Sa e ava i 1,a'b4e a1; °.ttle` iob _.l to r^i { or t c! • t h0..at�a xt ` Crfi' `,anv G rp~ .�, , t . i s t, . � .. r .tr t ctiOn. The e "'ciucc,ment �r�'i'� ta -.be nt;, intaini d and a'vai 1 akrie Lttlt�til tiria1' T i nspect�,ion apprOivra1 i_ gs anted 5 A i ,: 0nstru tiori tc� ; -i. , , rn r d t�s,� !k� don't �tl. unfr�r.ntanr.e wi t1.s �ap�r p1,, t t1 crld reauit�ente�lt ut th '.Lin1$urm POI ldin de :'.3 97 '1 4 u as amended T tlrl i i ottm i�techan ��a l .:ude f 19`975:E i' Wash1n+Qt,un ta.te ,Ever '. Co d&;'` 1.-997 Edi.t 'ton ) . 6 0.1 ty` o$ Pet tni The issuar «; ut a `LL'-J.nyit or aupro' i uf , ;lans spersi ieati d• an'd c.iniot :t'a tiuns' -hall not !r ired}�:t he r er�nti •.�1 T ` u� an prouef: of t any •�SEri oiattoh' Citj , anv t?t tie` ",p,r -ry I Sri § n t • the , bu:i i ii i nc e de or of 'env- , v. 1 er:.u rdinsn'ce of- l iAdir'tic5ri Nu • per niit ur; :esumi t0 a c tt c,rUri';iu of thi e acttti�r`rt•.y tc� �ria`lat�: ur- �-: r° e! �- � dude shall be va l i ci' jl.rAx. r e •"'�: °i,. ° .. • ` S 1 . b u rt i t v tlmt I h ye • read the :, °ru r t i,url and w r i ; 1 i • canrrr l v 1i Al iit'z r u'uC'1.1 ned '1 Eire v j 1 n : ut '1 a w ='nd nr`r1 l 1arice uOVe 1Ii r i11 be r i . e d with, , wYieth.er a'uecifi;ed °'herein ter not ky fnt ,Hamr=;. • ie grant :ih i`;ot ti permit does not presume tc, r:ive. author ' ' to . i'ul :ate or:Noancel F> h'e orovlsions of any other. "wc w orr loc:.a1 'ietw_ u la t i n9 cdr s,truct ion or ` the , .nerf;or manse " of wcu kr, f' 'one t Lire 4.a !ate : .6 • • ZZ . et 2 w; 0 0: No CO rL w 0 : g W Q; . 0 la W 0 0 . w LL O ; w z OF : Prot T " e of Insp ioC Address: I ''• /��t j L)afe called: Special in'strucbons: / :::::: Phone: Inspector: INSPECTION NO. COMMENTS: INSPECTION RECOf - ` , Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila ; WA 98188 Approved per applicable codes. Or 7 4 PERMIT NO. (206)431 -3 Corrections required prior to approval. Date: / _ L:.v ✓'�l $47.00 REINSPECTION p at 6300 Southcenter BIv ., Suite 100. Call to schedule reinspection. Receipt No: REQUIRED. Prior to inspection, fee must be paid Date: t ,, agit,ma r f �Alai�►T'`r Project �y /J / 4� ( ��ate`i`lled: Typ�eof Inspection � � v Address: 7 J 3? . C. a ( --- z-7--C Sp6cial instructions. /47: '-D Date wanted / ��"Z�/ P.m. Requester: Phone 1 Z? f 3 INSPECTION NO. • Approved per applicable codes. INSPECTION RECORL Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Mal -a4 PERMIT NO. (206)431 -3670 COMMENTS: Corrections required prior to approval. 00 REI JSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Prot: t � " Type of InspeltIdn: Address: I 1 . 3.7 500 ,er nw •P Date called: 6,-.22 -0 1 Special instructions: 1 Date wanted: /� te D`V (ra.m. `p -rtit�' Requester: Phone: Sane •��arrw «:. INSPECTION NO. 'CiTY TUKWILA BUILDING DIVISION 6300 Southcenter'Blvd #100,.Tukwi la; .WA 9818 Approved per applicable INSPECTION RECORf Retain a copy with peril . - nr.7 77 -mo PERMIT NO. (206)431 -3670 %Corrections required prior to approval. COMMENTS: I j• C< 1 f' -. red Ct tr.-A Q sk O ct L\ 04 r beTC- - p cAkA r () K $47.00 FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: K., x 16 iir x t ject: I k.c.., Type of Inspe tion: F -, 1 ress: sc P t� ate ! 1 2 D 1 Special instructions: Date ant d: � 3If`%/ p .m. -(' Phone: 7C — L t 2 ' — 5 INSPECTION RECOR( Retain a copy with pern)It " INSPECTIO NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 l IrtD f Gig PERMIT NO. (206)431 -3$7 Approved per applicable codes. g Corrections required prior to approval. COMMENTS: 4 s4//7.-44w7-, L/4 49 Lie y7 dti - e- �� < e %-( / 47 a • Insp ector: Date :/' Q $47.00 REINSPECTION I;' REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: *sutil45.: rSili J SY1tr +" g •ecuaihatisaSkiSeMIUgga P rt�ect';.'; .;Y1. koYI of Inspection: Tvne O11 h -1` ► Ad .J PY atefa duo Special instructions: ' ,' . Date wanted: a.m. CLol r , Req,ue§ter P b - * 92 - ` iZ7D INSPECTION RECUR Retain a copy with pearl/ ION NO. :TUKWIIA.BUILDING DIVISION 300'Soiathcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. n Corrections required prior to approval. COMMENTS: ,1 fr OMNI .ti■a.tme $47. EINSPECTIO N REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 3r 4 Project: i arci V (.Uc !- a of Inspection: C _ l T O u Y� Address: '.J 1�13'a SG P Dgalled:. Date - n 1 Special instructions: D to anted: 5 °1 m. l i yy Pya INSPECTION RECO Retain a copy with permit cOSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 .j . 7 7 1 7 . 77 7 : 1 717 7 77777777: 4 7 : 77 • r ° PERMIT NO. Approved per applicable codes. n Corrections required prior to approval. COMMENTS: 4 7 ; ; lid X 7:00 EINSPECTION FEE ` EQUIRED. Prior to inspection, fee must be paid - �: ^`at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. .Receipt . No: Date: o� ct: av k � c.arkS a of Inspecti o c,+' ' f 15tA t Y Address: . J )7i a. `� -.- . t Y t c led: D ' � 2 3 � 1 Special instructions: D ted �J I a.m. p.m. fesSe f: pz _ c0S — .33q0 'INSPECTION RECD Retain a copy with permit INSPECTION NO. 'CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. • Iv oI -0 PERMIT NO. (206)431 -36 COM ENTS: JR— Vf to t Gt 7e_- t f ) to Gi 4 () - \ rout t rt « ()JoUel- Corrections required prior to approval. 7.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid Southcenter Blvd., Suite 100. Call to schedule reinspection. eceipt, No• Date: : ,5 `cga; ;Vida s:a '! kk .w g "l G is =1a -. t L *4Ga k A*AA * *** *AA*AAAAA *A:*• *AA 1. A*AAAA'AAA:1AAAA:A• *.kr* *•*AAA• *•.t AA*A *AtA*A'. CITY OF . 111-:1 ! I L FI . Y! A ," 1` R A N S M 17 *c**** * *. A •k ** ** ***AA *AAAA•k AAA :k• *A*AAA•k *AAAAAAAAAAAAkAA*A R4t4 H mber' 8.01007:1.7 ,Amount: i.7.13 06/01/01 09:20 N4zwiiien Methott.'.'CHECK : Notation: JEFF SCHEIF.Eft Iniit: 131..H P'erm i i; No: ,M0.1 048 Tvoa: 3H1ECH MECHANICAL PERMIT parcel No 262304"- 907 S i to Addi a 17332: SOi!THCEN1 ER nY Total Fees : 7 -6 94 t ::T 3 Paymen :17,.13 Total ALL ' Pmts ~ 76.94 ce .00. A { t*,**ic lk- kA *zN *AA *'4.io.4** *A A ° * *A *#AI el * **** *A*A * *irtk**4 ** c* *.*1. *.4l,* *A Y1j c,munt Coil: Desar• i pt ion Amount 0o 0t / 4 1.830 PLAN : CHECK NONRES 3.43 MECiHANICAL NONRES 13.70..`' 1743 k :O F' UKY�I:LA lA Ist:0/Ml' t', *h*•k *icAk.4hk ** *4c14 t ** 4k:hfirilr * *•k ** *AA. h A. k t ii�!_8MIT =: hiumber :`R0 0052Q: Ar►ci�ir�� ; :'81 04.r.' . 68 « X47 av,iner� ` Met.hod s ' CHC:[;K Not . t:t o ED • $,.Y, S E Iri i .J f)) t: i @a . 140 0413 Tvpf ' : I3 -MECH .: 11ECHANICNL _ 2 2x304 -7.07 Hdd� ^es� 1733 rt)U t HCEU I ER NY.: T ai; a l ri "� 59 iii ' To (ALL ')?aii s 59 wHl Rll ai cOg • DD,. ** * *Aiie* ** A ** A******** A k*** c* *A * *doA * *dc;*A *s :**h *A ** de li esqri hti:1 af1,, Amount CHECK - r }ONRES • i0 •t4 Cf c L NONR 7.l3� (. NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. SPECIFICATIONS DIVISION 1 GENERAL REQUIREMENTS A. CONSTRUCTION DOCUMENTS I. DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE COMPLIMENTARY. SPECIFIC INFORMATION' MAY BE FOUND IN EITHER OR BOTH. 2. THE TERM 'OWNER' AS STATED IN THE FOLLOWING SPECIFICATIONS AND CONSTRUCTION DOCUMENTS, REFERS TO THE TENANT OF THIS SPACE CELT AND DOES NOT REFER TO THE LANDLORD OF THE PREMISES. 3. ANY DISCREPANCIES, ERRORS OR OMISSIONS DISCOVERED IN THE CONTRACT DOCUMENTS BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF OWNER BEFORE PROCEEDING WITH RELATED WORK; OTHERWISE, THE CORRECTION OF SUCH ITEMS IS THE RESPONSIBILITY OF THE CONTRACTOR. 4. APPROVED VARIANCES TO THE PLANS AND SPECIFICATIONS ON ONE PROJECT SHALL NOT CONSTITUTE AN APPROVAL OF LIKE VARIANCES ON SUBSNT TNT PROJECTS. B. OWNER DIRECTIVES I. THE CONTRACTOR SHALL FURNISH FULL TIME CONTINUOUS SUPERVISION. THE PROJECT SUPERINTENDENT SHALL REMAIN ON SITE THROUGH THE MERCHANDISE DATE OR THE COMPLETION OF THE PUNCHLIST WHICHEVER 15 LAST TO OCCUR. 2. SUSPENSION OF ALL CEILING AND OVERHEAD FRAMING IS TO BE FROM STRUCTURAL MALL BEAMS AND TOP CHORDS OF TRUSSES ONLY, NOT FROM MALL DECK. 3. GENERAL CONTRACTOR MAY SUBSTITUTE METAL FRAMING MEMBERS SHOWN ON DRAWINGS WITH ALTERNATE CODE APPROVED FRAMING METHODS AND GAUGE SIZES WITH APPROVAL OF OWNER'S CONSTRUCTION MANAGER. 4. GENERAL CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF IN -WALL BLOCKING FOR ALL ITEMS IN STORE. REVIEW DRAWINGS THOROUGHLY. 5. ALL OWNER - FURNISHED MATERIALS ARE FURNISHED TAILGATE DELIVERY ONLY. THE CONTRACTOR IS RESPONSIBLE TO UNLOAD, EXAMINE, AND TRANSPORT MATERIALS FROM THE POINT OF OFF -LOAD TO TOE JOBSITE OR STORAGE AREA AS APPLICABLE. MATERIALS WILL BE DELIVERED TO THE CLOSEST AVAILABLE TRUCK DOCK OR OTHER LOCATION AS DIRECTED BY THE LANDLORD. 6. THE CONTRACTOR IS RESPONSIBLE FOR DAMAGE, LOSS, THEFT, OR DESTRUCTION OF ALL OWNEP,- FURNISHED MATERIALS. TOE CONTRACTOR HILL BE BACK - CHARGED THE FULL COST OF REPLACEMENT MATERIALS INCLUDING FREIGHT CHARGES. 7. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF EACH TRADE WITH OTHER TRADES. CONTRACTORS SNAIL NOT BE ENTITLED. TO - ADDITIONAL COMPENSATION FOR CONFLICTS WHICH RESULT FROM LACK OF COORDINATION OF THE INVOLVED TRADES. B. THE GENERAL CONTRACTOR SHALL 'EMPLOY SUBCONTRACTORS NOD ARE EXPERIENCED AND WHO EMPLOY EXPERIENCED TRADESMEN. 9. 11-15 GENERAL CONTRACTOR SHALL NOT EMPLOY NOSY CONSTRUCTION TECHNIQUES OR EQUIPMENT WRING MALL OR STORE HOURS. W. THE CONTRACTORS SHALL WORK IN COOPERATION AND HARMONY WITH THE LANDLORD AND THE ADJACENT TENANTS IN SCNEDULING WORK IN ORDER TO CAUSE THE LEAST INCONVENIENCE TO PERSONNEL AND PROPERTY. IF SECIURT• IS REWIRED WHILE WORKING IN ADJACENT TENANTS SPACE, THIS COST WILL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. II. THE CONTRACTOR SHALL NOT UTILIZE GAS- OPERATED EQUIPMENT IN OCCUPIED SHOPPING CENTERS. ONE CONTRACTOR SHALL WORK IN HARMONY WITH THE LANDLORD'S REQUIREMENTS RELATING TO NOISE ABATEMENT AND SAFETY. 12. THE CONTRACTOR SHALL FURNISH DUMPSTERS AS REWIRED FOR THE EXCLUSIVE USE BY STORE PERSONNEL DURING MERCHANDISING. THE CONTRACTOR SHALL INCLUDE IN THE BID A MINIMUM OF ONE 40 -YARD CLOIPSTER R THE EQUIVALENT. IF THE SALES AREA EXCEEDS 8,000 SQUARE FEET, THE CONTRACTOR 'WALL INCLUDE ONE ADDITIONAL DVTIPSTER. 13. GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR THE COST OF ANY AND ALL OFF -SITE STORAGE OF OWNER SUPPLIED MATERIALS. c. ' DEMOJTION AND SPACE PREPARATION 1. WITHIN FIVE (5) DAYS OF COMMENCEMENT OF CONSTRUCTION, OR WITHIN TWO (2) DAYS FOLLOWING COMPLETION OF DEMOLITION, THE CONTRACTOR SHALL CAREFULLY EXAMINE THE SITE AND REPORT TO THE OWNER'S. CONSTRUCTION MANAGER ANY DISCREPANCIES IN THE LEASE -HOLD DIMENSIONS OR CONFLICTS BETWEEN THE 'PHYSICAL SPACE AND THE INTENT OF THE WORKING DRAWINGS. N.C. TO PAY SPECIAL ATTENTION TO POP -UP CEILING AREAS, CEILING HEIGHTS, AND AVAILABLE HEIGHT FOR ROLL -UP ENTRANCE GRILLES). 2. GENERAL CONTRACTOR IS TO CONTACT LANDLORD' ON -SITE MANAGER PRIOR TO ANY DEMOLITION WORK TO DETERMINE THE AVAILABILITY OF DUMPSTER PLACEMENT, NOISE AND DUST ABATEMENT REQUIREMENTS, ETC. 3. GENERAL CONTRACTOR 15 TO ARRANGE PNITH TINE LANDLORD A CONVENIENT TIME TO PERFORM DEMOLITION WORK AND INSTALL IPI(P(SARY PROTECTED MEANS OF EGRESS FROM REWIRED EXITS, INCLUDING TEMPORARY LIGHTING AND SAFETY DEVICES, ALL N ACCORDANCE WITH GOVERNING STATE AND LOCAL CODE AND LANDLORD REQUIREMENTS. 4. GENERAL CONTRACTOR TO ERECT BARRICADE AT STOREFRONT PER LANDLORD'S SPECIFICATIONS. GENERAL CONTACTOR TO INSTALL OWNER-SUPPLIED BARRICADE SIGN (IF PROVIDED) AS SHOWN ON INSTRUCTIONS SENT WITH BID PACKAGES. 6. 1145 GENERAL CONTRACTOR SHALL REMOVE, REPAIR, RESTORE AND REPLACE WHERE NECESSARY OR INDICATED ON THE DRAWINGS OR AS REWIRED. CUT ALL NECESSARY OPENINGS FOR ANY . REWIRED PURPOSE AND REPAIR, WHERE NECESSARY,. AFTER CUTTING. INSOFAR AS POSSIBLE, ALL PROTRUSIONS, MARKS, CRACKS OR OTHER EVIDENCE OF A DEFICIENT OR DAMAGED CONDITION SHALL. BE ELIMINATED UNLESS SPECIFICALLY NOTED OTHERWISE. ANY PARTS WHICH ARE SPLIT, CRACKED, CHIPPED, SPALLED, BROKEN, MISSING, OR OUT OF LINE OR ADJUSTMENT, MECHANICALLY OR STRUCTURALLY UNSAFE OR UNSOUND, BENT, TORN, OR OTHERWISE DEFICIENT OR INJURED IN ANY MANNER, SHALL BE REMOVED, REPLACED RESTORED, OR SATISFACTORILY REPAIRED AS DIRECTED BY THE OWNER'S CONSTRUCTION FWNAGER. N. GENERAL CONTRACTOR IS RESPONSIBLE PEA THE REMOVAL AND DISPOSAL OF ALL LEASE -HOLD IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO INTERIOR WALLS, CEILINGS, FLOOR COVERINGS (ALL ADHESIVES), PLATFORMS, STORE- FRONTS, ETC., (UNLESS INDICATED OTHERWISE ON ARCHITECTURAL DRAWINGS). ALL EXISTING UNUSED MECHANICAL, ELECTRICAL AND/OR PLUMING FIXTURES AND EQUIPMENT, INCLUDING ABANDONED ROOFTOP HVAC EQUIPMENT AND CURBS (UNLESS INDICATED OTHERWISE ON MECHANICAL AND ELECTRICAL DRAWINGS) AND /OR SKYLIGHTS ARE TO BE REMOVED AND THE ROOF PATCHED PER ITEM 5(2 BELOW: CAPPING IS EAST PERMITTED I 7. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL LOOSE ITEMS SUCH A5, BUT NOT LIMITED TO TRADE FIXTURES, MISCELLANEOUS DECORATIONS, KITCHEN EQUIPMENT, ETC. EXISTING SIGNAGE TO BE REMOVED BY GC. GC TO PREP/ PATCH/ CLEAN BEFORE NEW SIGNAGE IS INSTALLED. 8. ALL ABANDONED ELECTRICAL/TELEPHONE CONDUIT, PLUMBING LINES AND MECHANICAL DUCTWORK MUST BE REMOVED TO THE POINT OF ORIGIN. 9. INFORM THE LANDLORD'S ON -SITE MANAGER OF ANY UTILITY NEEDING TO BE DISCOFANECTED OR CAPPED, PRIOR TO DOING SO. 10. GENERAL CONTRACTOR IS TO EXERCISE EXTREME CARE DURING DEMOLITION SO AS NOT TO DAMAGE OR DISRUPT UTILITIES OR SPRINKLER LINES WHICH MIGHT PASS THROUGH THIS SPACE TO SERVICE OTHER MALL SPACES OR OTHER TENANTS. N.C. WILL BEAR 50LE RESPONSIBILITY FOR ANY SUCH DAMAGE OR DISRUPTION). II. REMOVE ALL EXISITING FLOOR FINISHES AND PREPARE CONCRETE SLAB FOR NEW FLOOR FINISHES. PATCH, REPAIR AND LEVEL POSTING SLAB. INFORM OWNER OF ANY IRREGULARITIES IN EXISTING SLAB IMMEDIATELY. 12. GENERAL CONTRACTOR IS RESPONSIBLE TO PATCH AND /OR REPAIR EXISTING FLOOR SLAB, DEMISING WALLS AND ROOF DECK AFTER COMPLETION OF DEMO- LITION AND PRIOR TO COMMENCEMENT OF NEW CONSTRUCTION (G.C. MUST CONTACT LANDLORD PRIOR TO ANT ROOF HONK AND COORDINATE ACCORD- INGLY). 13. GENERAL CONTRACTOR IS RESPONSIBLE TO REMOVE ALL EXISTING TENANT EXTERIOR SIGNAGE AND PATCH AND/ OR REPAIR EXISTING LANDLORD SOFFIT FASCIA AND NEUTRAL PIERS TO LIKE NEW CONDITION PRIOR TO COMPLETIONN OF NEW STORE CONSTRUCTION. 14. GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION WORK AND MUST INFORM OWNER'S CONSTRUCTION,MANAGER OF THE EXTENT OF SUCH WORK, PRIOR TO BIDDING. FOR THE FLOUR OR IS TO DETERMINE HIS RESPONSIBILITY 15. GENERAL CONTRACTOR DET SLAB AND DEMISING WALL INSTALLATION OR MODIFICATIONS WITH LANDLORD- AND OWNER'S CONSTRUCTION MANAGER TO MEET ALL TENANT IMPROVEMENT CRITERIA AND RESPONSIBILITY SET BY THE LANDLORD OR OWNER. GENERAL CONTRACTOR IS TO VERIFY THE ACTUAL CONDITION OF THE PERIMETER DEMISING WALLS AND/OR FLOOR SLAB PRIOR TO BIDDING. BID 15 TO INCLUDE ALL WORK REWIRED. K, JPSIFD(ATP Y UPON COMPLETION OF DEMOLITION AND PRIOR TO STARTING OF CONSTRUCTION, JOB SUPERVISOR TO VERIFY AND ADVISE OWNER'S aigiTELICTZELEISHEOSE a. OVERALL WIDTH (FACE/GYPSUM BOARD ON DEMISING WALL TO FACE/ GYPSUM BOARD ON DEMISING WALL). b. OVERALL LENGTH (LEASE LINE TO INNER -FACE OF GYPSUM BOARD ON REAR WALL.) c ANY AND ALL COLUMN LOCATIONS - FREE STANDING OR PROJECTING. d. AVAILABLE CLEAR HEIGHT FOR GRILLE AND CEILING AS DIMENSIONED ON DRAWINGS. D. LAYOUT OF WORK I. EXERCISE PROPER PRECAUTION TO VERIFY ALL EXISTING CONDITIONS AND LAYOUT OF WORK. CONTRACTOR TO NOTIFY OWNER'S CONSTRUCTION MANAGER OF ANY DISCREPANCIES IMMEDIATELY. CONTRACTOR 15 RESPONSIBLE FOR ANY ERROR RESULTING FROM FAILURE TO EXERCISE SUCH PRECAUTION. SUCH ERROR WILL NOT BE CONSIDERED SUBSEQUENTLY AS A BASIS FOR EXTRA COMPENSATION. 2. SHOULD A CONTRACTOR FIND DISCREPANCIES IN, OR OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS, OR SHOULD HE BE IN DOUBT AS TO THEIR MEANING, HE SHALL AT ONCE NOTIFY THE OWNER'S CONSTRUCTION MANAGER. 3. GENERAL CONTRACTOR 15 RESPONSIBLE FOR SUPPLYING OR RENTING ALL TOOLS, WELDERS, GENERATORS, ETC. FOR COMPLETING PROJECT. E. CODES AND STANDARDS I. ALL WORK, MATERIALS AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH ALL ORDINANCES, STATE AND LOCAL BUILDING CODES, LATEST EDITION, AND FOLLOW APPLICABLE LANDLORD REQUIREMENTS. 2. DESIGN LOADS: LOADS AND CODE RESTRICTIONS FOR ALL DESIGN CONSIDERATIONS SHALL CONFORM TO THE LOCAL AND STATE CODES, AND ALL GOVERNING CODES. F. GENERAL CONDITIONS I. THE AMERICAN INSTITUTE OF ARCHITECTS DOCUMENT A201 'GENERAL CONDITIONS OF THE CONTRACTOR FOR CONSTRUCTION IS A PART OF THE CONTRACT DOCUMENTS. DIVISION II SITEENoRK A. NO WORK UNDER THIS SECTION, UNk55 NOTED OTHERWISE ON CONSTRUCTION DRAWINGS. DIVISION III' CONCRETE A. THE CONTRACTOR IS REPONSIBLE TO DETERMINE IF A NEW CONCRETE SLAB IS REQUIRED IN ALL OR PART OF THE LEASED SPACE. SUCH FLOOR SLAB SHALL BE INSTALLED IN ACCORDANCE WITH ALL REQUIREMENTS, LOCAL CODES, OR COMMON STANDARDS OF PRACTICE TO THE LOCALITY OF THE PROJECT OR WHICHEVER IS STRICTER. IN TEE ABSENCE OF THE ABOVE, THE CONTRACTOR SHALL CONTACT THE OWNER FOR DIRECTION. MINIMUM REQUIREMENTS FOR TEE FLOOR SLABS ON GRADE SHALL BE FOUR INCH THICK CONCRETE SLAB REIN- FORCED Wf M 6 6'W.W.F.; CONCRETE TO BE 3,600 PSI OR HIGHER PLACED OVER SIX MILL VAPOR BARRIER OVER COMPACTED SAND /AGGREGRATE BASE. THE SOIL SHALL BE INSECT TREATED IF CUSTOMARY TO THE LOCALITY OR AS RE- WIRED SY LANDLORD. B. FOR SPECIFICATIONS OF RAISED PLATFORMS IN STORE (IF APPLICABLE),. REFER TO DETAILS OF THIS SET. DIVISION IV MASONRY A. THE CONTRACTOR SHALL ACCOMPLISH ANY MISCELLANEOUS ANEOUS MASONRY,. WORK INDICATED. ON THE PLANS, OR NOT INDICATED ON THE PLANS YET INCIDENTAL TO THE ACCOMPLISHMENT OF OTHER. WORK. WHERE APPLICABLE, MASONRY WORK SHALL MATCH EXISTING WORK. FINISH BRICK WORK SHALL BE NEATLY TOOTHED INTO EXISTING MASONRY IF APPLICABLE. DIVISION V MPR'E I ANEOUS METALS A. STRUCTURAL STEEL: REFER TO STRUCTURAL DRAWINGS (IF APPLICABLE). B. METAL STUDS: GALVANIZED STEEL STUDS SIZED AS INDICATED ON DRAWINGS OR AS REWIRED. INCLUDE ALL ACCESSORIES, SUCH AS BRIDGING, TP_.CK, ETC. PROVIDE ALL MISCELLANEOUS BOLTS, CLIPS, ANCHORS, ANGLES, BRACKETS, SLEEVES, FASTENERS, AND OTHER METAL ITEMS AS REQUIRED. WOOD 51105 MAY BE SUBSTITUTED WHERE PERMISSIBLE BY CODES. C. DECORATIVE METALS: INSTALL OWNER - PROVIDED DECORATIVE METAL SUCH AS STAINLESS STEEL, FREFINI514ED METAL, ETC. AS INDICATED ON DRAWINGS, PER MANUFACTURER'S RECOMMENDATIONS. DIVISION VI CARPENTRY A. PROVIDE HEN LUMBER, BEARING GRADE AND TRADEMARK OF ASSOCIATION UNDER WHICH IT WAS PRODUCED. B. LAYOUT, CUT, FIT AND ERECT FRAMING FOR ROUGH AND FINISHED WORK. INSTALL BLOCKING, HAILERS, FURRING AND OTHER ROUGH AND FINISHED MATERIALS AS • REWIRED. BRACE, PLUMB AND LEVEL MEMBERS IN TRUE ALIGNMENT AND RIGIDLY SECURE IN PLACE WITH SUFFICIENT NAILS, SCREWS AND BOLTS AS NECESSARY. C. USE NON- CD'BUSTIBLE/FIRE RETARDANT LUMBER AND TRIM WHERE REWIRED BY STATE OR LOCAL CODES, WHICH BEAR THE MANUFACTURER'S STAMP OF AUTHENTICITY. D. FURNISH AND INSTALL ALL GROUNDS OR BLOCKING REQUIRED TO RECEIVE STORE FIXTURES. E. FURNISH AND INSTALL ALL ROUGH HARDWARE, ANCHORS, BOLTS, ETC., AS REQUIRED FOR CARPENTRY WORK. F. MILLWORK I. RECEIVE AND INSTALL ALL FINISHED MILLWORK, CABINET WORK, PANELING, DOORS, FRAMES, ETC., AS SHOWN ON DRAWINGS OR AS DIRECTED. 2. CUT AND FIT ALL: MILLWORK AND SET PLUMB AND TRUE. S. COPE ALL IN- CORNERS, MITER ALL CUTSIDE CORNERS. 4. SAND ALL SURFACES TO 5MODT14 AND EVEN FINISH. 5. BACK OUT FLAT TRIM TO PREVENT WARPING. DRILL WHERE NECESSARY TO PREVENT SPLITTING. 6. FIT ALL DOORS TO LEAVE EQUAL SPACES ON ALL SIDES. 7. IT 15 THE CONTRACTOR'S RESPONSIBILITY TO PROTECT ALL FINISHED MILLWORK WITS VISWEEN, CARDBOARD, ETC. 5. ALL G.C. SUPPLIED LUMBER FOR FINISHED CARPENTRY SHALL BE MILLWORK GRADE HARDWOOD. DIVISION VII THERMAL AND MOISTURE PROTECTION A. ROOFING/FLASHING I. GENERAL CONTRACTOR TO CONTACT LANDLORD'S ON -SITE MANAGER FOR SPECIFICATIONS ON ROOF PATCHING OR NAME OF ROOFING CONTRACTOR TO CONTACT FOR REPAIRS. INSULATION I. GENERAL CONTRACTOR TO PROVIDE AND INSTALL RIGID AND /OR FULL BATT INSULATION AND VAPOR BARRIER AT WALLS AND CEILING AS REQUIRED BY LANDLORD AND CONSTRUCTION DRAWINGS. C. SKYLIGHTS (NOT APPLICABLE) DIVISION VIII DOORS AND WINDOWS A. DOORS AND HARDWARE 1. DOOR HARDWARE: REFER TO EOM SCHEDULE FOR HARDWARE SPECIFICATIONS. 2. HOLLOW METAL FRAMES: 00. MINIMUM 16 GAUGE. SIZE AND SHAPE PER DOOR SCHEDULE. 3. LABELED DOORS, WHERE REQUIRED, PROVIDE U.L. LABEL DOORS AND FRAMES PER APPLICABLE STATE AND LOCAL BUILDING CODES. LABEL DOORS'. TO RECEIVE DOOR CLOSER. 4. FABRICATE AND ERECT TRUE, PLUMB AND SQUARE AS SPECIFIED AND AS DETAILED AND PER MANUFACTURER'S RECOMMENDATIONS. B. ROLLING GRILLE I. ROLL LNG GRILLE PROVIDED AND INSTALLED BY OM ER. 2. CAREFULLY COORDINATE INSTALLATION AND NOOK -UP OF ROLLING GRILLE WITH ALL AFFECTED TRADES. REFER TO DOOR SCHEDULE. 3. INSTALLATION BRACKET AT GRILLE SUPPORT POST BASE MUST FACE MALL CORRIDOR SIDE. C. GLASS AND GLAZING 1. GLASS A STOREFRONT GLASS TO BE HORIZONTALLY TEMPERED. SIZE AND NO SER OF PIECES AS SAOAN ON DRAWINGS. GLAZING CONTRACTOR TO PROVIDE AND INSTALL ALL GLAZING CHANNELS, GASKETS, BLOCKING, ETC., REQUIRED FOR COMPLETE INSTALLATION. PROVIDE NEAT, UNIFORM (V4' WIDE UNLESS NOTED OTHERWISE) GAPS BETWEEN GLfSS PANES AND BETWEEN PANES AND ADJACENT VERTICAL SURFACES. b. ARRIS EDGE EDGES TO BE DIAMOND GROUND 1/16 45 DEGREE BEVEL AT FRONT AND BACK FACES WITH ALL EXPOSED EDGES UNIFORMLY MACHINE POLISHED. c. OWNER REQUIRES THAT STOREFRONT GLASS NOT BOW MORE THAN +0- I/16 OUT OF VERTICAL. d. ALL GLASS TO BE SET IN GLAZING GASKETS THE SIZE AND SHAPE NECES- SARY TO ACCOMPLISH GOOD WORKMANSHIP. CAULKING NOT PERMITTED. a. GLAZING CLIPS ARE NOT TO BE USED UNLESS REWIRED BY LANDLORD OR CODE. IF REQUIRED, GENERAL CONTRACTOR SHALL USE BLACK ROUND CLIPS MANUFACTURED BY LAMBERT SHEET METAL 3776 EAST FIFTH AVENUE, COLUMBUS, OHIO (614) 237 -0304. F. ALL EXTERIOR GLAZING TO RECEIVE 3M 'SCOTCHSNIED WINDOW FILM It5CLARL ISO SUPPLIED AND INSTALLED BY G.C. CONTACT: SOLAR TEX INC. (614) 508 -6211. 2. MIRRORS a. MIRRORS: NOTED (M -I) TO BE I/4' CLEAR PLATE PROVIDED AND INSTALLED BY CONTRACTOR WITH CONTINUOUS BRIGHT, SAINT ALUMINUM 5/8' J- CHANNEL TOP AND BOTTOM BIILO64SSP BY C.R. LAWRENCE CO., LOS ANGELES, CALIFORNIA, (800 -421 -6144) SET IN MASTIC. b. INSTALL LARGEST SIZE POSSIBLE TO ACHIEVE THE LEAST NUMBER OF VERTICAL JOINTS. HORIZONTAL JOINTS ARE NOT ACCEPTABLE, EXCEPT WHERE INDICATED OTHERWISE ON DRAWINGS. e. ALL EDGES OF MIRRORS TO BE FLAT GROUND AND POLISHED TO CREATE A 0(100TH FINISH. NO ROUGH EDGES ON MIRRORS WILL BE PERMITTED. D. ENTRANCE AND STOREFRONT 1. INSTALL STOREFRONT AS SHOWN ON DRAWINGS, CAREFULLY COORDINATING ALL TRADES INVOLVED. , DIVISION IX FINISHES A. GYPSUM DRYWALL I. FURNISH AND INSTALL ALL GYPSUM DRYWALL AND SYSTEMS COMPLETE WITH PARTITION FRAMING, CEILING SUSPENSION SYSTEMS AND RELATED ACCESSORIES, PARTS, MATERIALS, ETC. AS SHOWN ON DRAWINGS AND AS SPECIFIED. INSTALL ALL MATERIALS PER MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. 2. GYPSUM DRYWALL: U.S. GYPSUM 5/0 THICK FIRE CODE SNEETROCK (TYPE 'X') PANELS OF STANDARD QUALITY. GENERAL CONTRACTOR MAT USE NON- RATED S/0'.WICK BOARD IN AREAS OF STORE WHERE ALLOWED BY STATE AND LOCAL CODES. ALWAYS USE TYPE 'X' GA DEMISING HALLS. 3. FASTENERS, DRYWALL SCREWS OF PROPER SIZE AND TYPE, PER MANUFAC- TURER'S RECOMMENDATIONS. 4. METAL ACCESSORIES U.S. GYPSUM OR GOLD BOND SYSTEM OF COMPONENTS AND JOINT TAPE. 5. JOINT TREATMENT: U.S. GYPSUM OR GOLD BOND SYSTEM OF COMPONENTS AND JOINT TAPE. B. CEILING SYSTEMS I. FURNISH AND INSTALL CEILING SYSTEM COMPLETE WITH SUSPENSION SYSTEM AND RELATED ACCESSORIES AS 34OWN•ON DRAWINGS AND AS SPECIFIED. 2. SUSPENSION SYSTEMS SHALL BE ADEQUATE TO SUPPORT LIGHT FIXTURES, CEILING, GRILLES, DIFFUSERS AND OTHER NORMAL ACCESSORIES. PROVIDE SYSTEM COMPONENTS FROM A. SINGLE MANUFACTURER. 3. INSTALL CEILING AND SUSPENSION SYSTEMS IN STRICT ACCORANCE WITH MANUFACTURER'S RECOMMENDATIONS. FINISH CEILING SHALL BE LEVEL, WITH JOINTS SNUG AND SQUARE, AND TILES OR PANELS IN PERFECT CONDITION. 4. INSTALL SECURITY GRID CLIPS ON FIRST TWO TILES AT LAY -IN CEILINGS AROUND PERIMETER OF STORE (IF CODE OR LANDLORD REQUIREMENTS PROHIBIT GYPSUM BOARD ON DEMISING WALLS TO RUN FULL HEIGHT TO DECK). 5. ALTERNATE BID OPTION, G.C. MAY USE A CHIGACO METALLIC CM 650 SERIES GRID TYPE DRYWALL SUSPENSION SYSTEM FOR ALL DRYWALL CEILINGS LEIEBE LSE ALLOWS - SUBMIT SPECIFICATION TO OWNER'S CONSTRUCTION MANAGER ONION TO CONSTRUCTION 6. MATERIALS AND FINISHES a. REFER TO DRAWINGS FOR LOCATION OF SPECIFIED MATERIALS AND FINISHES. b. SALES AREA CEILING (IF SHOWN ON REFLECTED CEILING PLAN), CIRRUS SCORED BEVELED TEGULAR 2' x 2' DESIGN %5 WHITE METAL GRID TO BE ARMSTRONG SUPRAFINE ML EXPOSED TEE SYSTEM, PREFINISHED TO MATCH TILE. CONTACT: DENISE WARFEL P 1- 800 - 442 -4212 TO VERIFY NATIONAL ACCOUNT PRICES. MUST ALLOW MINIMUM OF (2) WEEKS AVAILABILITY. c. NON -SALES CEILING. ARMSTRONG 2' X 4' NON - DIRECTIONAL FISSURED OR EQUAL. TILE AND GRID TO BE WHITE, GI ASS 'A' RATING. A. WHEN A ONE -HOUR FIRE -RATED CEILING ASSEMBLY IS ,REQUIRED ST LAND - LORD, STATE. OR LOCAL CODES, THEN GENERAL CONTRACTOR IS TO CONFORM WITH UNDERWRITER'S LABORATORIES - DESIGN FOR A ONE -NOR RATED ASSEMBLY. USING THE CEILING CHOICES LISTED BELOW: FIRE -RATED NON -SALES AREA CEILING: ARMSTRONG NO. AREA GEORGIAN, 2' x 4' PANEL WHITE FINISH: METAL GRID TO BE WHITE. E. G.C. 15 TO PROVIDE CNE BOX OF THE SPECIFIED CEILING TILES ON SITE FOR FUTURE USE. C. PAINTING, FINISHING AND WALLCOVERING I. THE INTENT IS TO PROVIDE A SATISFACTORY FINISH TO ALL PARTS OF THE PROJECT, WHETHER NOTED HEREIN OR NOT, UNLESS SPECIFICALLY STATED. OTHERWISE, COVER ALL SURFACES THOROUGHLY. IF THE NUMBER OF COATS SPECIFIED DOES NOT ACCOMPLISH THE INTENT, THEN APPLY ADDITIONAL COATS OF SPECIFIED MATERIAL TO GIVE SATISFACTORY COVERAGE. SEE FINISH SCHEDULE. 2. PAINT CONTRACTOR 15 TO REVIEW ELEVATIONS, FLOOR AND WALL FINISH PLANS, CONSTRUCTION DETAIL SHEETS, REFLECTED CEILING PLAN, AND PRESENTATION PLAN/DETAILS FOR HELPFUL CLARIFICATION OF ITEMS AND SURFACES TO BE PAINTED. REQUEST SHEETS. FROM HOME OFFICE IF REQUIRED. 3. BEFORE STARTING FINISH WORK, REMOVE HARDWARE, ACCESSORIES, PLATES, LIGHTING FIXTURES AND SIMILAR ITEMS, OR PROVIDE AMPLE PROTECTION FOR SUCH ITEMS. 4, USE ONLY THE PAINT AND RELATED MATERIALS OF THE MANUFACTURER'S SPECIFIED. 5. CLEAN ALL SURFACES TO BE PAINTED FREE OF LOOSE DIRT AND DUST BEFORE WORK 15 STARTED. 6. PAINTED DRYWALL TO RECEIVE {NE- COAT OF LATEX PRIMER AND ONE COAT OF SPECIFIED PAINT. TINT PRIMER TO APPROXIMATE SHADE OF THE FINAL COAT. TOUCH UP ALL SUCTION SPOTS OR 1407 SPOTS AFTER APPLICATION OF FIRST COAT AND BEFORE APPLYING SECOND COAT, TO PRODUCE AN EVEN RESULT IN THE FINISH COAT. DRY ALL COATS THOROUGHLY BEFORE APPLYING SUC- CEEDING COATS. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR RECOAT TIME. 7. STAINLESS STEEL, ALUMINUM, CHROME - PLATED SURFACES AND ALL OTHER BRIGHT METAL FINISHES SHALL NOT BE PAINTED UNLESS DIRECTED OTHERWISE. S. WASH ALL METAL SURFACES WITH MINERAL SPIRITS TO REMOVE ALL DIRT AND GREASE BEFORE APPLYING FINISH. .WHERE RUST AND /CR SCALE IS PRESENT, WIRE BRUSH OR SAND CLEAN BEFORE APPLYING FINISH. 9. ALL METAL SURFACES PAINTED BY PAINT CONTRACTOR ARE TO BE PRIMED WITH A. HIGH QUALITY METAL PRIMER (UNLESS NOTED OTHERWISE).' FINISH COATS. MUST NOT. REVEAL BRUSH MARKS. SPRAY OR APPLY AS NEEDED, 10. PUTTY ALL NAIL HOLES, COUNTERSINK SCREWS, BOLTS, CRACKS, ETC. BEFORE APPLYING FINISH. I ALL WOOD SU ACES TO BE PAINTED AND EVEN BEFORE APPS I SAND RF SM00T ° - Y LNG FINISH. 12. 4 ENERAL CONTRACTOR TO. APPLY ALL STAINS PER MANUFACTURER'S SPECIFICA- TIONS. APPLY STAIN TO CLEAN/DRY SURFACES ONLY. 13. PAINT ALL .ACCESS DOORS,' FIRE EXTINGUISHER CABINETS, EQUIPMENT' MOUNTING BOARDS, ETC. 1N/ON GYP. BOARD WALLS AND /OR CEILINGS. PAINT TO MATCH ADJACENT WORK UNLESS OTHERWISE NOTED OR DIRECTED. 14. 5CND ENAMELED FINISHES APPLIED TO WOOD OR METAL BETWEEN COATS WITH FINE SANDPAPER TO PRODUCE'SMOOTH, EVEN FINISH. 5. MAKE FINISH WORE UNIFORM OR APPROVED FINISH, SMOOTH, FREE OF RUNS, SAGS, DEFECTIVE BRUSHING MD CLOGGING. MAKE EDGES OF PAINT ADJOIN- ING OTHER MATERIALS OR COLORS SHARP AND CLEAN WITHOUT OVERLAPPING. - 5. FIELD PAINTING, EXCEPT TOUCH-UP, WILL NOT BE REQUIRED ON ITEMS SPECIFIED TO BE COMPLETELY FINISHED AT FACTORY (PRE - FINISHED), UNLESS SPECIFICALLY DESIGNATED. 17. WALL COVERINGS: REFER TO FINISH SCHEDULE AND FINISHES AS NOTED ON DRAWINGS FOR, LOCATION AND EXTENT. a. INSTALL ALL MATERIALS BY SKILLED WORKMEN, IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. b. SEAL DRYWALL BEFORE APPLICATION OF WALL. COVERING WITH LATEX PRIMER. FINISH TO BE SMOOTH. c. ADHESIVES USED IN THE APPLICATION OF WALL COVERINGS TO BE PRE- - MIXED AS RE... ENDED BY MANUFACTURER FOR THE SURFACES INVOLVED. d. HAVE FINISHED INSTALLATION FREE OF BLISTERS, WRINKLES CR OTHER DEFECTS. HAVE ALL SEAMS TIGHTLY CLOSED. MATCH ADJACENT STRIPS AS REWIRED CONSISTENT WITH PATTERN SELECTED. AVOID CORNER SEAMS WHEN POSSIBLE. e. IF CLEANING IS REQUIRED, USE ONLY MATERIALS AND METHOD RECOMMEN- DED BY MANUFACTURER OF WALLCOVERING USED. F. CONTRACTOR IS RESPONSIBLE FOR UNROLLING AND CHECKING FABRIC FOR DEFECTS IMMEDIATELY UPON DELIVERY. DO NOT HANG DEFECTIVE FABRIC. D. FLOOR PREPARATION FOR FINISH FLOORING I. THE GENERAL CONTRACTOR SHALL EXAMINE POSTING SLAB CONDITIONS TO DETERMINE TO WHAT SITEOT FLOOR PREPARATION, LEVELING, CHIP HAMMERING, ETC. WILL BE NECESSARY TO FURNISH A SMOOTH, LEVEL SUBSTRATE FOR THE PROPERHSTALLATION OF ALL FLOURING MATERIALS. THE COST OF SUCH WORK TO THE EXTENT THAT IT CAN BE DETERMINED DURING THE BID PROCESS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR- UNEVEN SUBSTRATE WILL NOT BE ACCEPTED AS AN EXCUSE FOR POORLY INSTALLED FLOORING MATERIALS. E. CONTROL AND EXPANSION JOINTS FOR FINISH FLOORING i. THE CONTRACTOR L• RESPONSIBLE TO PZITIONE THE SUBSTRATE AND INSTALL. CONTROL OR EXPANSION JOINTS AS REWIRED WE TO EXISTING CONDITIONS. PATEN CONTROL JOINTS/EXPANSION JOINTS ARE REWIRED, THE CONTRACTOR IS TO CONTACT THE OWNERS CONSTRUCTION MANAGER FOR APPROVAL OF METHODS OR SYSTEMS PRIOR TO INSTALLATION. F. CERAMIC TILE I. CERAMIC TILE AS SPECIFIED IN FINISH SCHEDULE AND RESPONSIBILITY SCHEDULE. (IF APPLICABLE) 2. INSTALL CERAMIC TILE USING RECOPTI IDED METHODS OF THE TILE CONTRACTORS ASSOCIATION OF AO•'�7cI:A AND THE TILE COUNCIL OF AMERICA, INC. 3. INSTALL CERAMIC TILE USING GROUT AND JOINT SPACING SPECIFIED IN FINISH SCHEDULE 4, ADHESIVE IS TO BE PROVIDED AND INSTALLED BY.GENERAL CONTRACTOR (PER MANUFACTURER'S SPECIFICATIONS). _5. CAREFULLY CLEAN ALL WORK AND REPLACE OR REPOINT ANT DAMAGED WORK AND LEAVE IN PERFECT CONDITION. USE NO ACID, AGENT OR DEVICE TEAT WILL MAR SURFACE. CONSULT WITH OWNER'S 01±11101X1121 FOR INSTRUCTIONS, (CO NOT POLISH CERATIIC TILE)). 6. CERAMIC TILES ARE TO BE SET WITHOUT TRIPPING HAZARD TO CUSTOMERS OR STAFF. 7. THE GENERAL CONTRACTOR 15 RESP° ONSBLE TO CORR T RAISED CERAMIC TILES FOR THE ENTIRE DURATION OF THE WARRANTY PERIOD AT THE DIRECTION OF THE OWNER'S CONSTRUCTION MANAGER. G. CARPET (NOT APPLICABLE) 14. VINYL RESIUENT TILE (NON - SALES) I. VB' X 12' X EY VINYL RESIUENT TILES WITH 4' NIGH X I/8' THICK TOP- SET COVED TAUPE VINYL BASE SEE FINISH SCHEDULE. BUTT BASE TO FLOOR AND WALL 141714 NO GAPS, 2. FILL ALL CRACKS, JOINTS, ETC. IN SUB -FLOOR WITH CRACK FILLER APPROVED BY FLOORING MANUFACTURER. INSTALL ALL MATERIALS WITH WATERPROOF TYPE ADHESIVES AS RECOMMENDED BY FLOORING MANUFACTURER FOR MA- - TERIALS AND SURFACED INVOLVED. J. WOOD FLOORING I. INSTALL AS SPECIFIED IN FINISH SCHEDULE AND RESPONSIBILITY SCHEDULE. 2. PATCH 'TOP Of SLAB TO OBTAIN A 51100T14, FLUSH SURFACE_ 3. IT IN CRITICAL THAT THE WOOD FLOOR BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S DIRECTIONS SHIPPED WITH THE MATERIALS. INITAIL CARE OF THE FLOORING IS TO INCLUDE THE APPLICATION OF 'HART SPRAY SHIELD' (SUPPLIED BY OWNER) AND BUFFING WITH A COMMERCIAL BUFFER. WITN AGN- SPEED BUI'FEUK (1000 RPM AND ABOVE) USE A NIGH -SP® PAD (I.E. 3M SUPER -HIGH SPEED PAD). WITH LOW -SPEED BUFFERS (BELOW 1000 RPM) USE A MEDIUM COARSE NYLON PAD (I.E 3M RED PAD). G.G. TO NEVER DAMP MOP. 4. WOOD FLOORING - ADHESIVE PROVIDED BY OWNER AND APPLIED BY GENERAL CONTRACTOR. CLEANER PT.OVIDED BY OWNER FOR USE WHEN NEEDED. (PER MANUFACTURER'S SPECIF,CATIOS).., 5. INSTALL WOOD FLOORING WITH ALL SEAMS FLUSH AND TIGHT, WITH NO GAPS. (CUT TO FIT AS REQUIRED). 6. WOOD FLOORINGS SHALL BE PROTECTED AT ALL TIMES WITH CARDBOARD, CRAFT PAPER, '. ETC. PROTECTION SHALL REMAIN IN PLACE UNTIL TINE FINAL CLEANING PROCESS. 7. 36' x 36'CENTIVA CONCRETE SERIES VINYL TILE BY INTERNATIONAL FLOORS O AMERICA. STYLE: CC, COLOR, 6204, SURFACE, E13055ED, EDGE: STANDARD BEVELING. DIVISION X SPECIALTIES AND MISCELLANEOUS A. CABINET WORK I. PREFINISHED CABINETS ARE SUPPLIED BY OWNS. AND SHIPPED TO JOB SITE UNASSEMBLED.. GENERAL CONTRACTOR 15 TO ASSEMBLE ALL CABINETS REFER- RING TO CONSTRUCTION AND INSTALLATION DETAILS OF THIS SET. 2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR UNLOADING, INSPECTING AND STORAGE OF CABINET COMPONENTS. GENERAL CONTRACTOR SHALL IMME- DIATELY INFORM OWNER OF ANY DISCREPANCIES IN TYPE OR AMOUNT OF CABINET COMPONENTS OR ANY DAMAGE. 3. GENERAL CONTRACTOR SHALL TAKE PRECAUTIONS DURING STORAGE TO ENSURE COMPONENTS ARE NOT DAMAGED. 4. GENERAL CONTRACTOR GHAT I ASSEMBLE AND INSTALL CABINETS IN LOCATIONS SOWN ON PLANS 0. GENERAL CONTRACTOR SHALL TAKE PRECAUTIONS DURING INSTALLATION NOT TO DAMAGE PREFINISHED COMPONENTS. b. GENERAL CONTRACTOR TO FASTEN COMPONENTS TOGETHER PLACING FASTENERS AS INCONSPICUOUSLY AS POSSIBLE. REFER TO INSTALLATION DETAILS OF THIS SET. c. GENERAL CONTRACTOR IS TO INSTALL ALL COMPONENTS WITH EXPERIENCED FINISH CARPENTERS ONLY TO ASSURE QUALITY ASSEMBLY. B. ACCESS PANEL FOR GYPSUM BOARD CEILING STANDARD ACCESS PANEL USE KARP MODEL ND5C -2141 (24' x 24 PRIME COATED STEEL WITH RING TURN LATCH. FIRE -RATED ACCESS PANEL USE KARP MODEL StERP -150 FR (24' x 24') PRIME COATED STEEL WITH RING TURN LATCH. SUPPLIER. KARP ASSOCIATES, INC. MASPETH, NEW YORK (710)76•. -2105 C. ACCESS PANELS, FOR NVAC EQUIPMENT ARE NORMALLY INDICATED ON THE HVAC AND REFLECTED CEILING PLANS. ' IN ABSENCE Of DEFINED LOCATIONS, THE GENERAL CONTRACTOR IS TO FURNISH AND INSTALL ACTF'SS PANELS AS NEC- ESSARY TO FURNISH REASONABLE, SAFE ACCESS.TO SERVICE ALL SERVICEABLE COMPONENTS OF EACH PIECE OF EQUIPMENT. ASSUMED ACCESS SMALL BE BY A TECHNICIAN(S) STANDING FIRMLY ON A' LADDER. WHERE AGTESS PANELS OR REMOVABLE DIFFUSERS CANNOT BE LOCATED.. IMMEDIATELY ADJACENT TO THE THE CONTRACTOR 15 TO FURNISH A NON - COMBUSTIBLE CATWALK OR ABOVE CEILING SECURED FLANKING CR METAL DECKING OR SIMILAR.NONCOM- BUSTIBLE MATERIAL TO ACCESS TO THE EQUIPMENT FROM THE NEAREST ACLE- TO IFS DIFFUSER. CATWALKS MUST BE OBST FREE 5 D FFll PANEL FO r 0 I NUT AC . CATWALKS MUST BE CAPABLE HABLE HT OF 3 FELT 0 INCHES ABOVE THE CATWALK (2) PLUS CAPAB OF SAFELY SUPPORTING A MINIMUM: OF TWO ) EQUIPMENT AND BE CONSTRUCTED OF NON- CF71'18119'TIBLE MATERIALS. ,D. THE GENERAL CONTRACTOR I5 RESPONSIBLE TO ASSEMBLE ALL MISCELLANEOUS NON- SALES AREA WALL STANDARDS, SHELVES, BRACKETS, ETC. E. LAVATORY FIXTURES, REFER TO MECHANICAL DRAWINGS AND DETAIL A/AI2.4. LAVATORY ACCESSORIES. REFER TO DETAIL A/Al2.4 AND RESPONSIBILITY SCHEDULE. F. RESTORE LANDLORD'S STRUCTURAL STEEL FIREPROOFING TO MAINTAIN INTEGRITY G. TURN OVER REQUIREMENTS: I. THE CONTRACTOR SHALL TURN OVER THE PROJECT IN A CLEAN, DUST FREE, DIRT FREE CONDITION. THE CONTRACTOR SHALL EMPLOY A PROFESSIONAL CLEANING SERVICE EMPLOYING ONLY TRAINED PERSONNEL. CLEANING SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: I. STOREFRONT GLASS (INSIDE AND OUT) 2. MIRRORS 3. STOREFRONT METAL 4. SIGNS 5. CABINETS, INCLUDING SHELVING, BASES, VALANCE, FILLERS AND END PANELS 6. LIGHT FIXTURES INCLUDING CANS, TRIM, TRACK AND TRACK HEADS 7. FLOORING (PER MANUFACTURER'S RECOMMENDATIONS) 8. VINYL RESILIENT FLOOR TILE CLEANED AND WAXED 9. PRESENTATION ITEMS, PROPS, AND TRADE FIXTURES 10. WOOD BASE II. WALL COVERINGS 12. NON -*. FT SHELVING, STORAGE PLATFORMS, ETC. UPON COMPLETION OF MERCHANDISING, GENERAL CONTRACTOR TO RE -CLEAN STORE TO DUST -FREE, DIRT -FREE CONDITION. 2. GENERAL CONTRACTOR 15 RESPONSIBLE FOR ASSEMBLY AND PLACEMENT OF OFFICE AND NON -SALES EQUIPMENT AND FURNITURE 3. THE CONTRACTOR IS RESPONSIBLE TO UNCRATE, ASSEMBLE, AND PLACE TRADE FIXTURES AND PRESENTATION ITEMS IN SALES AREA. FIXTURES TO BE LOCATED PER THE DIRECTION OF THE OWNER. 3. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE A 30 YARD DUMPSTER FOR STORE USE DURING MERCHANDISING. G.C. IS TO HANDLE REMOVAL OF DUMPSTER AFTER STORE MERCHANDISING. DIVISION XI EQUIPMENT A. NO WORK UNDER THIS SECTION, UNLESS NOTED OTHERWISE ON CONSTRUCTION DRAWINGS. DIVISION XII FURNISHINGS A. NO WORK UNDER THIS SECTION, UNLESS NOTED OTIIE ON CONSTRUCTION DRAWINGS. DIVIEION XIII SPECIAL CONSTRUCTION A. NO WORK UNDER THIS SECTION, UNLESS NOTED OTHERWISE ON CONSTRUCTION DRAWINGS. DIVISION XIV CONVEYING SYSTEMS A. NO WORK UNDER THIS SECTION, UNLESS NOTED OTHERWISE ON CONSTRUCTION DRAWINGS. DIVISION XV DIVISION XVI MECHANICAL ELECTRICAL A. SEE MECHANICAL AND ELECTRICAL DRA14ING5 FOR SPECIFICATIONS. GENERAL INFORMATION CONSTRUCTION TYPE: TYPE IV UNPROTECTED OCCUPANCY LOAD: sALES 2253/30 - 77 NOR -SALES 712 • 3 TOTAL T7+3 ED KEY PLAN USE GROUP: MERCANTILE AI.I A2,1 A3,1 A4.1 A5.1 A6.1 A7.1 AB.I A9.1 A9.2 A10.2 A10,3 A10. A10.5 A10.4 A10.7 AII.I AIl.2 Al2.I Al2.2 Al2.3 Al2.4 E/I E/2 ED /I ED/2 ES /1 M/I MD /1 MS /I DRAWING INDEX TITLE AND SPECIFICATION. SHEET NOTES AND SCHEDULES CONSTRUCTION AND FIXTURE PLAN OPEN. #.. LIGHTING PLAN • FLOOR AND WALL FINISH PLAN PRESENTATION PLAN INTERIOR ELEVATIONS OPEN NUMBER STOREFRONT PLAN DETAILS 4 ELEVATIONS STOREFRONT SECTIONS. OPEN NUMBER OPEN NUMBER OPEN NUMBER FASHION FOCAL DETAILS MARKETPLACE (BATH) DETAILS OPEN NUMBER PERFORMANCE DETAILS DETAILS OF WALL BEHIND BACKWRAP DEMONSTRATION AREA DETAILS CONSTRUCTION DETAILS CONSTRUCTION DETAILS OPEN NUMBER NON -SAL FS DETAILS ELECTRICAL' POWER PLAN ELECTRICAL LIGHTING PLAN ELECTRICAL DETAILS ELECTRICAL SCHEDULES t RISERS ELECTRICAL SPECIFICATIONS MECHANICAL PLAN MECHANICAL SCHEDULES 4 DETAILS MECHANICAL SPECIFICATIONS L I I I T E D STORE PLANNING,PC. BATH AND BODY WORKS STORE NUMBER - 1755 PARKWAY SUPERCENTER SPACE NUMBER - 17332 17332 SOUTHCENTER PARKWAY TUKWILA, WA 98188 TENANT BATH 6 BODY WORKS THREE LIMITED PARKWAY COLUMBUS, 01410 43230 (614) 415 -7000 TENANT'S REPRESENTATIVES KENNETH KOSINSKI - #1650 PROJECT MANAGER PAUL TETER - # 7858 PROJECT EXPEDITER DEVELOPER REVISIONS M5K NORTHWEST 503 - 636 -2800 TENANT COORDINATOR DAVID MOORE 4.149 S.W. MEADOWS ROAD, SUITE 675 LAKE OSWEGO, OR .17035 503 -636 -2800 CONSULTANTS ARCHITECTURAL CHRISTOPHER LEET HUNGERLAND BAINBRIDGE ISLAND, WA MECHANICAL / ELECTRICAL INNOVATIVE DESIGN ENGINEERING ASSOC. COLUMBUS, OHIO FILE COPY I understand that the Plan Check apprayals are subject to 517pr1 and emissions and approval of plans does not authorize the violation of any adapted code or ordinance. Receipt of con- tractors copy of approved plans acknowledged. B - 9.. Date r ' 25 fll Permit No. • Qdiri REVISIONS TU A EUILCINS AREA CALCULATIONS APPROX. GROSS AREA - 2996 SQ. FT. APPROX. WIN SALES AREA - 2234 SQ. FT. APPROX. BEN NON -SALES AREA - 712 SQ. FT. LINEAR FEET OF STOREFRONT ISSUED: 03 -02 -2001 BID DATE: 03 -02 -2001 (-OL CI7V OFTUKV4(A TITLE SHEET (614) 4154 IC FARE 1T ° :siiT REQUIRED FCR: [; :`.1ECFiAi•.ICAL " E- OL'JMDING GAS T::lUG CITY CF TUKWILA BUILDING OIVISI'ON lM4 STATEOFORReIR N PEa341 CCfr. 21 -V 1-F. CFI O 44" A.F.F. ELECTRICAL SERVICE. SEE POTTER RISER DIAGRAM ON SHT. ED.2 A -17 LAV NON —SALES 70 MDP TO MDP 4 REGISTER CASH/WRAP COUNTER USE CIRCUITS A- 1.305 L LEO. WHR. HTR. 12DV., 1e, 1sKw POWER GENERAL NOTES 1. THE ABBREVIATION L.S.P., WHEREVER IT APPEARS IN THESE ELECTRICAL DRAWINGS, SHALL REFER TO 'UMITEO STORE PLANNING. INC. ". ANY REFERENCE TO TENANT'S, OR BATH AND. BODY WORKS, OR FURNISHED BY ANY OF THE. ABOVE, REFERS TO LS.P. 2. THE CONTRACTOR FOR THIS YORK IS REQUIRED TO READ THE SPECIFICATIONS AND RENEW DRAWINGS OF ALL DIVISORS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONRBIUTY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR CLARITY. CIRCUITING STALL BE "THRU— WRING" WHERE AND WHENEVER POSSIBLE. CORRIDOR 4. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT MTH MECHANICAL CONTRACTOR PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT. 5. ALL RECEPTACLE CIRCUITS UP TO 100' -0' SHALL GOUGE #t2 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS FROM 101' -0" TO 150' -0" IN LENGTH SHALL UTIUZE /10 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS 151' —O UP TO 250' -0" IN LENGTH SHALL UUUZE /B CONDUCTORS MINIMUM. CIRCUITS '..AROVE.. 251' -0" SHALL UUUZE AS CONDUCTORS MINIMUM. 8. PLACEMENT OF ALL RECEPTACLES IN THE "SALES' AREA SHALL BE INTENTIONAL (LE. — CENTERED ON COLUMNS, WALL FEATURES OR TIGHT TO CORNERS). IF THE RECEPTACLE IS NOT SHOWN IN A DESIRABLE LOCATION, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH LS.P. PROJECT MANAGER PRIOR TO ROUGH —IN. 7. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUI,,... FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 8. THERE DRYWALL CEIUNGS ARE USED IN THE "SALES' AREA, THE ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS THE USE OF JUNCTION BOXES ABOVE DRYWALL CEIUNGS SHALL BE UNITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED. ON PLANS FIELD COORDINATE 'MTH LS.P. PROJECT MANAGER PRIOR TO ROUGH —IN TO AVOID ANY CONFLICTS. JUNCTION BOXES ABOVE LAY —IN CEILINGS ARE ACCEPTABLE. 9. EQUIPMENT LABELED "CUTLER HAMMER" SHALL BE FURNISHED BY LS.P. AND INSTALLED BY. THE ELECTRICAL CONTRACTOR. REFER TO CODED NOTES, ELECTRICAL RESPONSBIUTY SCHEDULE, PANEL SCHEDULE AND POWER RISER DIAGRAM FOR SPECIFIC EQUIPMENT DESCRIPTION. 10. REFER TO SHEETS ED.T. ED.2 AND ES.1 FOR DETAILS. SCHEDULES AND SPECIFICATIONS 11. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INQUIRE NUN THE LANDLORD'S REPRESENTATIVE ON. ANY FIRE. ALARM SYSTEMS IN USE AT THE MALL AT THE TIME OF THE BID. IF THE FIRE ALARM SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS, THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR AND INCLUDE THE COST AS A SEPARATE UNE ITEM IN THE BID. NO ADDITIONAL MONIES SHALL BE AWARDED FOR TIE —IN REQUIREMENTS TO A LANDLORD'S FIRE ALARM SYSTEM THAT IS IN EXISTENCE AT THE TIME OF THE BID. WITHOUT A SEPARATE UNE ITEM FOR THE FIRE ALARM SYSTEM AT THE TIME OF THE MD. - - `I=TS 1r ; P ' 12. THE ELECTRICAL CONTRACTOR MUST INCLUDE. IN HIS BID TWO (2) HOURS OF STARTUP'. FOR THE LIGHTING CONTROL SYSTEM. THE ELECTRICAL CONTRACTOR. WILL BE REQUIRED TO REPAIR OR REPLACE COMPONENTS FOUND TO BE DEFECTIVE. THE ELECTRICAL CONTRACTOR MUST COORDINATE. UGHTNG CONTROL STARTUP MTH CARRIER CORPORATION CONTROLS STARTUP. FAILURE TO DO SO MAY REQUIRE THE ELECTRICAL CONTRACTOR TO RETURN TO THE JOB STE TO PERFORM STARTUP ON A FUTURE DATE AT THE ELECTRICAL CONTRACTORS OVA EXPENSE. 11 ALL 24 VOLT COMMUNICATION AND /OR SENSOR WRING ASSOCIATED WTH THE L.S.P. FURNISHED 'CARRIER' DDC CONTROL SYSTEM SHALL BE PRODDED BY LSP. AND INSTALLED BY THE ELECTRICAL CONTRACTOR. ALL THE WRING AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WIN THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE, LOCAL CODES AND LANDLORD REQUIREMENTS. 14. ANY PENETRATION THROUGH THE ROOF OR WALL WTH CONTROL WRING MUST BE IN CONDUIT. POWER CODED NOTES RECEPTACLES AND COVERPLATES DESIGNATED OF SHALL BE *HIE IN COLOR, FURNISHED BY LS.P. AND INSTALLED BY. ELECTRICAL CONTRACTOR WHERE SHORN ON PLANS IN THE UNDERSIDE OF THE STOREFRONT SOFFIT WTH THE 4' SDE PARALLEL TO THE STOREFRONT GLASS. FIELD VERIFY EXACT LOCATION OF ALL RECEPTACLES WITH LS.P PROJECT MANAGER PRIOR TO ROUGH -IN OF RECEPTACLE'. BOXES. RECEPTACLES AND COVERPLATES DESIGNATED "C" SHALL BE IVORY' IN COLOR, FURNISHED BY LS.P. AND INSTALLED BY ELECTRICAL CONTRACTOR, MOUNT ALL RECEPTACLES 15" A.F.F. FIELD VERIFY EXACT LOCATION OF ALL RECEPTACLES WTFI L.S.P. PROJECT MANAGER PRIOR TO ROUGH -IN OF RECEPTACLE BOXES. c> F.I. RECEPTACLE FOR DRAIN PUMP 0 1E1" A.F.F. 0 RECEPTACLES AND COVERPLATES LOCATED IN "NON — SALES'. 'H.C. LAY' AND /OR "CORRIDOR" AREAS SHALL BE WHITE IN COLOR. FURNISHED BY L.S.P. AND INSTALLED. BY ELECTRICAL CONTRACTOR. MOUNT ALL RECEPTACLES AT 18". AF.F. EXCEPT AT NOTED ON FLOOR PLAN. GELD VERIFY EXACT LOCATION OF ALL RECEPTACLES WITH LS.P. PROJECT. MANAGER PRIOR TO ROUGH—IN OF RECEPTACLE BOXES. TELEPHONE OUTLET IN WALL. ELECTRICAL CONTRACTOR TO RUN A 3/4" EMPTY CONDUIT. WTH PULLMRE BACK TO TELEPHONE BOARD. TELEPHONE WARE AND pJI4C JACK FOR TWO UNE TELEPHONE (BY OTHERS). SEE FLOOR PLAN FOR MOUNTING HEIGHT. REFER TO " TELEPHONE /COMPUTER SYSTEM SCHEMATIC' ON SHEET ED.1 FOR ADDITIONAL INFORMATION. J—BOX FOR POWER .CIRCUIT FOR TELEPHONE AND NVAC/LJGHTING CONTROLS. VERIFY SYSTEM GROUNDING AND ALL OTHER REQUIREMENTS NTH LOCAL TELEPHONE COMPANY. EXTEND 1' TELEPHONE CONDUIT FROM TENANT'S TELEPHONE SERVICE ENTRANCE AT DEMISING WALL TO TELEPHONE SECTION OF IFS UNIT. VERIFY EXACT LOCATION IN FIELD. OO 120 VOLT UGHT/RECEPTACLE AT UNIT WIRED TO CIRCUIT AS INDICATED. UGHT/RECEPTACLE FURNISHED BY LS.P. AND INSTALLED BY THE ELECTRICAL CONTRACTOR.: REFER. TO SHEET ED.1 FOR ADDITIONAL INFORMATION. O INSTALL A DELIVERY BUZZER SYSTEM AS SHOWN ON DRAWINGS LS.P. SHALL PROVIDE PUSHBUTTONS, TRANSFORMER AND BUZZERS WITH LOUVERED COVERPLATES AND TRANSFORMER MOUNTING PLATE. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NECESSARY JUNCTION BOXES. CONDUIT AND WIRE TO COMPLETELY INSTALL THE DELIVERY BUZZER SYSTEM. REFER TO "DELIVERY BUZZER SCHEMATIC" ON SHEET ED.1 FOR ADDITIONAL INFORMATION. ® 20 AMP, 120 VOLT SINGLE PHASED ISOLATED DEDICATED CIRCUIT AND TWO (2) 20 AMP HUBBELL IIG -5382 RECEPTACLES WTH ISOLATED THIRD PARE GROUND. IN. A SINGLE 3/4' CONDUIT BACK TO ELECTRICAL PANEL FOR COMPUTER TERMINAL': DO NOT SHARE ANY PART OF THIS CIRCUIT WITH ANY BRANCH CIRCUITS MOUNT RECEPTACLES AND COVERPLATES (REFER TX SHEET ED.2 FOR MOUNTING HEIGHT'). FIELD VERIFY EXACT LOCATION WTH LS.P. PROJECT MANAGER PRIOR TO ROUGH —IN. REFER TO "TELEPHONE /COMPUTER SYSTEM SCHEMATIC" . ON SHEET ED.1 FOR ADDITIONAL INFORMATION. INSTALL 8" X B' X 4" PULLBOX, WTH COVERPLATE, ABOVE CEILING ON .WALL ABOVE MANAGER'S DESK AREA. INSTALL 1" CONDUIT, MTH PULLWRE, FROM PULLBOX TO A. 2" X 4 "' JUNCTION BOX IN WALL FOR COMPUTER TERMINAL (REFER TO SHEET ED.1 FOR MOUNTING HEIGHT). INSTALL 1' CONDUIT. 0TH PULLWRE, FROM PULLBOX ABOVE MANAGER'S DESK AREA TO CASH WRAP COUNTER IN 'SALES' AREA. DATA CABUNG BY OTHERS. REFER TO CASH WRAP /BACK URA° PLAN' AND "TELEPHONE /COMPUTER SYSTEM SCHEMATIC' ON, SHEET ED.1, FOR ADDITIONAL INFORMATION.. f0 11 12 14 15 DATA OUTLET IN A 2" X 4' JUNCTION. BOX FOR COMPUTER TERMINAL (REFER TO SHEET ED.1 FOR MOUNTING HEIGHT). ELECTRICAL CONTRACTOR SHALL INSTALL 3/4' CONDUIT, WITH PULLWIRE. TO TELEPHONE. BOARD. TELEPHONE. CABLE, DATA CABLE AND t ARJ11C JACK TO TELEPHONE BY OTHERS. FIELD VERIFY EXACT LOCATION VATH L.S.P. PROJECT MANAGER PRIOR TO ROUGH —IN.I REFER TO.'TELEPHONE /COMPUTER SYSTEM SCHEMATIC" CA SHEET ED.1 FOR ADDITIONAL INFORMATION. FOUR REGISTER. CASH VRAP/BACK WRAP COUNTER. ELECTRICAL CONTRACTOR TO PERFORM ALL WORK AS INDICATED IN THE "CASH WRAP/BACK WRAP PLAN' AS SHOWN ON SHEET ED.1. REFER TO ARCHITECTURAL FLOOR PLANS FOR EXACT ROUGH —IN INFORMATION. 4" X'. 4" JUNCTION. BOX IN WALL,' WTH COVERPLATE, INSTALLED AT 88' A.F.F. AND 120 VOLT QUADRAPLEX RECEPTACLE INSTALLED AT 88'' A.F.F. FOR SOUND SYSTEM. RUN A 3/4'. CONDUIT. WITH PULLMRE. UP IN WALL TO A 4" X 4" JUNCTION BOX ABOVE CEILING. ELECTRICAL CONTRACTOR TO RUN A 1/2" CONDUIT FROM JUNCTION BOX TO EACH SPEAKER LOCATION WHERE/NHEN REQUIRED BY CODE. REFER TO "SOUND SYSTEM INSTALLATION DETAIL' ON SHEET ED.1 FOR ADDITIONAL INFORMATION. LABEL AU. PANELS STARTERS, DISCONNECT SIWTCHES, ETC. AND FILL OUT CIRCUIT BREAKER. PANELBOARD LEGENDS.. TYPEWRITTEN. SEE PANEL SCHEDULE FOR CIRCUIT BREAKERS TO RECEIVE LOCKING DEVICES. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL AS A MINIMUM CONDUITS STUBBED FROM HVAC AND /OR UGHTNG CONTROLS (ON TELEPHONE BOARD IN IFS UNIT) TO 12" ABOVE CEILNG MTH PLASTIC CONDUIT BUSHING TO PREVENT WIRE CHAFFING. RECESSED RECEPTACLE WITH BRASS COVERPLATE AND BRASS CARPET RING IS TO BE SPECIFIED TO ACCEPT THE WOOD' FLOOR ABUTTING, TO BE FURNISHED BY LS.P. AND INSTALLED BY ELECTRICAL CONTRACTOR. FIELD VERIFY EXACT LOCATION OF ALL RECEPTACLES WTH LS.P. PROJECT MANAGER PRIOR TO ROUGH —IN OF RECEPTACLE BOXES. FILE COPY I understand that the Plan Check approvals ere subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractors copy of approved plans acknowledged. 'REVISIONS m___ NO CHANGES SHALL BE MART TO THE SCOPE OF 1A"JTK'WITHOUT PI ".1 7VAL OF TUKWILA BUILDING CIVI. h3TE: FIEV.ONS WILL FACIA. A NEW RAN &MANTA. MO MAY IMUJOE AOOMONAL FLAN FEWEN By Date Permit No. VERIFY ALL CONDITIONS IN FIELD PRIOR TO BIDS, ;F , MAY 1 8 2001 nrin IiT M RIn III H- U C) Z Z z Q W 10 01112 0 SHEET El OF UGHTING FIXTURES NON -SALES CORRIDOR 00.00 000000000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 - - A_ 8 x V ) o Tw) 0 V ° VVVVVVVV VVVVCDVVVVVV LIGHTING GENERAL NOTES 1. THE ABBREVIATION LOP., WHEREVER IT APPEARS IN THESE ELECTRICAL DRAWINGS, SHALL REFER TO UMITED STORE PLANNING, INC. ANY REFERENCE TO TENANTS, BATH AND BODY WORKS, OR FURNISHED BY ANY OF THE ABOVE REFERS TO LS.P. 2. THE CONTRACTOR FOR THIS WORK IS REWIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE YORK OF AU. SUBCONTRACTORS WITH ALL DI0SIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS NITH A COMPLETE SET OF BID DOCUMENTS. 1 LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS CIRCUITING SHALL BE . 11RU- WIRING' WHERE AND WHENEVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE UGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. UGHTNG FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE 'THRU- WIRING'. ANY RELATED COSTS FOR MULTIPLE CONNECTIONS SHALL BE INCLUDED IN BID. 4. SEE ARCHITECTURAL REFLECTED CEIUNG PLAN FOR EXACT LOCATION AND QUANTITY 5. ELECTRICAL CONTRACTOR'S BID SHALL INCLUDE THE INSTALLATION OF ALL . UGHT FIXTURES AND ASSOCIATED LAMPS FURNISHED BY LS.P.. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO ENSURE THE ADJUSTABIUTY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND AIM THEM. UGHT FIXTURE SPECIFICATIONS MAY VARY. IF THIS IS THE CASE, CONTRACTOR IS TO CALL ELGEE ELECTRIC AT (800) 244 -0947 FOR EXACT SPECIFICATION OF UNITED STORE PLANNING PROVIDED LIGHT FIXTURES. IF CEIUNG SYSTEMS ARE FIRE RATED, CONTRACTOR IS TO CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH ELGEE ELECTRIC . 8. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE (120/277 VOLT INPUT) WITH BATTERY BACKUP. CLOSELY COORDINATE INSTALLATION WITH LOP. PROJECT MANAGER. 7. ALL UGHTNG CIRCUITS UP TO 100' -0' IN LENGTH SHALL UTUZE /12 CONDUCTORS MINIMUM. ALL UGHTNG CIRCUITS FROM 101' -0' TO 150' -0' IN LENGTH SHALL UTUZE /10 CONDUCTORS MINIMUM. ALL UGHTNG CIRCUITS 151' -0' UP TO 250' -0' IN LENGTH SHALL UTILIZE /8 CONDUCTORS MINIMUM. CIRCUITS ABOVE 251' -0' SHALL UUUZE d6 CONDUCTORS MINIMUM. B. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 9. WHERE DRYWALL CEIUNGS ARE USED IN THE SALES AREA THE : IOTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE JSE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEIUNGS SHALL BE UNITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. FIELD COORDINATE WITH LS.P. PROJECT MANAGER PRIOR TO ROUGH -IN TO AVOID ANY CONFLICTS. ,UNCTION BOXES ABOVE LAY -IN CEILINGS ARE ACCEPTABLE. 10 EXIT/EMERGENCY UGHTS AT STOREFRONT ARE TO BE CEILING MOUNTED AND CENTERED OVER OPENING (TYPICAL U.N.O.). EXIT/EMERGENCY UGHTS AT DOOR TO 'NOR - SALES SHALL BE CENTERED ON WALL ABOVE DOOR. FIELD VERIFY EXACT LOCATION AND MOUNTING HEIGHT WITH LS.P. PROJECT MANAGER PRIOR TO ROUGH -IN. 11 ELECTRICAL CONTRACTOR SHALL INSTALL CLEAR PLASTIC LAMP SLEEVES PROVIDED BY LS.P. ON ALL FLUORESCENT LAMPS LOCATED ON CEIUNG' THAT ARE B' -O' ARE. OR BELOW (I.E. - LAAJAN\MGR). 12 UGHT FIXTURES INDICATED WITH SHADING WILL BE ZONE 'B' STOCKING LEVEL WHEN/F FUTURE UGHTNG CONTROLS ARE INSTALLED BY LS.P. 13 ELECTRICAL CONTRACTOR IS TO INSTALL OCCUPPANCY MOTION SENSOR. SNITCH FURNISHED BY L.P. FOR CONTROL OF ROOM LIGHTS AS SHOWN. E.C. SHALL SET SNITCH FOR 15 MINUTES. MOTION SNATCHES TO BE DESIGNATED 'MS ON FLOOR PLAN. A -2e SEE PARTIAL LIGHTING PLAN PARTIAL LIGHTING PLAN VERIFY ALL CONDITIONS IN FIELD PRIOR TO SIDS. A -38 UGHTNG CODED NOTES O PROVIDE JUNCTION BOX, TOGGLE DISCONNECT SNITCH IN NON - VISIBLE LOCATION AND FINAL CONNECRON FOR 120 VOLT SIGN FURNISHED BY LS.P.,INC. COORDINATE EXACT LOCATIONS WV LS.P. PROJECT MANAGER. EXTEND CIRCUIT THROUGH UGHTNG RELAY /CONTACTOR IN IFS UNIT. m( 0 'R MAY 1 8 2001 uJ U Z L� O U) Q Ci) (" Z CC 03 WWWw 3 W WC) � yH3 0 B 3 W he N ce Q he M CO 0. g 011120 SHEET E.2 V 3 . TWO 20 AMP. 120 WIT NFNICATFIT ISO ATFO CIRCUITS IN A 'EN(X F 1" CONDUIT EACH WITH A THIRD WIRE ISOLATE() GROUND RACK TO PANEL FOR CASH REGISTERS DO NOT SHARE ANY PART OF THIS CIRCUIT WflM ANY OTHER BRANCH CRCUTS, STUB CONDUIT UP 1" A.F.F. BELOW CASH WRAP UNIT. CONNECT 1' FLEXIBLE METALLIC CONDUIT TO STUB -UP AND EXTEND TO JUNCTION BOX IN CASH WINAP. RUN A 3/4' FLEXIBLE METALLIC CONDUIT FROM JUNCTION 80X TO EACH CASH REGISTER'S ISOLATED GROUND RECEPTACLE. RECEPTACLES SHALL BE HUBBELL 10 -5362. 20 AMP, ISOLATED GROUND TYPE FURNISHED AND INSTALLED IN CASH WRAP, WIRED BY ELECTRICAL CONTRACTOR. CUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT BELOW FLOOR SLAB TO WALL AS SHOWN. ROUTE CaJDUI7 CONCEALED IN WALL UP TO CEILING SPACE AND EXTENT TO PANEL. CASH W RAP/BACK WRAP CODED N41T5 TWO 1" CONDUITS WITH PULLWRES FOR DATA CABLING TO CASH REGISTERS WT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUITS BELOW FLOOR SLAB 70 WALL AS SHOWN. ROUTE CONDUITS CONCEALED IN WALL UP TO CEILING SPACE AND EXTEND TO AN 8'x8'%4' PULLBOX ON WALL ABOVE "MANAGER'S DESK AREA" IN ST ICROOM. DATA CABLING FURNISHED AND INSTALLED BY UNITED STORE PLANNING. SEE NOTE 9 ON SHEET E.1 FOR ADDITIONAL INFORMATION. ONE 20 AMP, 120 VOLT CIRCUIT IN 3/4" CONDUIT FOR UTILITY POWER. STUB -UP 1' A.F.F. UNDER CASH WRAP UNIT MD CONNECT TO DUPLEX RECEPTACLES FURNISHED AND INSTALLED IN CASH WRAP, VARED BY ELECTRICAL CONTRACTOR. CUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT BELOW FLOOR SLAB TO WALL AS SHOWN. ROUTE CONDUIT CONCEALED IN WALL UP TO CEILING SPACE AND EXTEND TO PANEL PROVIDE JUNCTION BOX FOR DUPLEX TELEPHONE OUTLET IN BACK WRAP CUTOUT. PROVIDE 3/4" CONDUIT 10TH PULLWIRE BACK TO TELEPHONE BOARD. TELEPHONE CABLE AND DUPLEX /RJ14C JACK FOR 2 -UNE TELEPHONES BY LIMITED STORE PLANNING. SEE NOTE 5Q ON SHEET E.1 FOR ADDITIONAL INFORMATION. BUZZER IN OUTLET BOX W/ LOUVERED COVERPLATE MOUNTED IN BACK WRAP CUTOUT. RUN 3/4" CONDUIT W/ 24V WIRING IN WALL UP TO CEIUNG SPACE AND EXTEND TO PUSHBUTTON. BUZZER SYSTEM SHALL BE FURNISHEUTY UNITED STORE PLANNING AND INSTALLED BY B&BW ELECTRICAL CONTRACTOR. SEE NOTE ON SHEET E.1 FOR ADDITIONAL INFORMATION. NOTE: ELECTRICAL CONTRACTOR MUST INSTALL CONDUITS AS SHOWN. EUMINATE INTERIM JUNCTION BOXES WHEREVER POSSIBLE. SUPPLY PULLWIRE IN EACH CONDUR. MAKE ALL FINAL ELECTRICAL CONNECTIONS TO RECEPTACLES, TELEPHONE OUTLETS. ETC. AS REQUIRED FOR A COMPLETE WORKING SYSTEM. NO CHASING OR CUTTING OF THE FLOOR SLAB, EXCEPT FOR SLABS ON- GRADE, WILL BE ALLOWED. ALL CONDUITS AND /OR PIPING MUST BE RUN BENEATH THE SLAB AND ALL SLAB PENETRATIONS SHALL BE FULLY SLEEVED AND FLASHED. COORDINATE ALL FLOOR SLAB CUTTING WOO MALL OPERATIONS MANAGER. I � 1" EMPTY CONDUIT MTH �� PULLWIRE 7 .....--FLOOR G ED. CD 8' FIXTURE WITH 4 -4' STAGGERED FLUORESCENT LAMPS NTS LANDLORD'S TELEPHONE CONDUIT ( ,, ,-- STUBBED INTO LEASE SPACE 3/4' EMPTY CONDUITS WITH PULLWIRES 2. SEE CASH/WRAP DETAILS ABOVE FOR NOTES AND SHEET E.1 FOR O NOTES. 0 DATA OUTLET NON - SALES TELEPHONE BOARD IN IFS UNIT 36" A.F.F. TO BIM. MANAGER'S DESK AREA ® TELEPHONE OUTLET NTS REFER TO PANEL SCHEDULE FOR CIRCUIT CONNECTIONS NOTES: 1. ADDITIONAL ®PHONE OUTLETS 3. FIELD VERIFY EXACT NUMBER MAY BE REQUIRED. SEE FLOOR OF CASH /WRAP COUNTERS. PLAN FOR LOCATION. SPENDER CEILING WALL TELEPHONE /COMPUTER SYSTEM SCHEMATIC SNL- 232 -120 -EBBS Vr CD 4' TWO LAMP I II STAGGERED FLUOR. L_ - _IL _IL_ .1 r (1) 6' FIXTURE WITH I I I 4 -3' STAGGERED II II FLUORESCENT LAMPS - H� II CO 8' FIXTURE WITH II II II L IIL F LAMP II - (1) 4' TWO LAMP 5� 87SNL- 232 -120V -EBBI STAGGERED FLUORESCENT CEILING GENERAL NOTES 1. ALL EQUIPMENT SHALL BE FURNISHED BY LIMITED STORE PLANNING AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. SHADOW BOX LIGHTING DETAIL 6TSNL- 225 -120V -EBBI 4" FROM FACE OF CASH WRAP- z S 1' EMPTY CONDUIT FOR TWO REGISTER CASH MAP. TWO I' EMPTY CONDUITS FOR FOUR AND SIX REGISTER CASH WRAPS PROVIDE PULLYARES IN EMPTY CONDUITS. DATA CABLING BY OTHERS. REFER TO CASH WRAP DETAIL THIS SHEET FOR ADDITIONAL INFORMATION. ONE ex ex 4' PULL BOX SURFACE MID. ON WALL ABOVE CEIUNG IN MGR'S DESK AREA 0® 1" EMPTY CONDUIT STUB -UP(s) NI7H PULLNIRE� BACK WRAP CASH WRAP PHONE OUTLET 2X4 J -BOX DESIGNATED ROUGH -IN AREA FOR MANAGER'S COMPUTER RAG(. SECTION NTS 36' REMOVABLE SHELF MOUNT IN CORNER OF COVE TIGHT TO VALE MP)' H CONDUITS UP IN WALL SPACE (TYP. SALES i 4Y1 ± r � \ I I I 1 ALIGN BOTTOM OF FIXTURE NTH TOP OF BTU -� STEELRICONDUIT VANIZED NTS r CASH WRAP COUNTER q I 1 ' IH' II II bb 1 I# I REFER TO PANEL SCHEDULE FOR CIRCUITING CASH WRAP /BACK WRAP PLAN NTT (4 REGISTER) 0 120V PRI. NOTE: COORDINATE EXACT LOCATION OF RECEPTACLE N UGJT WITH MECH. CONTR. SO AS NOT TO BLOCK ACCESS PANELS IB' REMOVABLE SHELF �(TYP OF 2) VOID SPACE UNDER SHADOW BOX. 3/16 0 TOGGLE BOLT WI 7 1/ex Box 6" WASHER (BOLT TRACK LENGTHS AT ENDS AND CENTER). TRACK TRACK ATTACHMENT DETAIL NTS REAR DOOR PUSHBUTTON DELIVERY BUZZER SCHEMATIC NTS STANCHION MOUNT UGHT FIXTURE KITH GLOBE AND WARD AND 100W. A -21 LAMP 3/4' BIRD GALVANIZED STEEL CONDUIT VITON /5299 -I COMBINATION SINGLE POLE SWITCH AND GM OUTLET IN REATHERPROOF SWITCH BOX � ROUTE CONDUIT UP THRU RTU FINISHED ROOF SURFACE RTU LIGHT /RECEPTACLE DETAIL CEIUNG MATERIAL 3/4" EMPTY C. W/PULLNIRE. ' — SALES BUZZER AT CASH WRAP NON -SALES BUZZER UNISMUT SUPPORT EAGLE /804 PORCELAIN LAMPHDLOER. NTN AN EAGLE 4898 METAL LAMP GUARD AND A 100A -19 LAMP. m BUILDING STRUCTURE II IS MORE THAN 7 -0" II ABOVE FINISHED CEILING. INSTALL JUNCTION BOX II AND LAMPHOLDER ON II A 3/4" CONDUIT SUPPORT SLAB EXTENDED DONN r 1 SO LAMPNODER -1! ABOVE AO MOPE THAN 7 EILI FINISHED COLINQ-�� NTT NOTES: LEVITON 45289 -I COAONATION SINGLE POLE SNITCH AND CFO OUTLET IN SNATCH BOX LOCATED BY MUMS ACCESS PANEL /AIR DEVICE.. ACK WRAP CASH TRAP i -I II . , I Immowl PHONE OUTLET (DUPLEX) SECTION NTS 1. FIXTURES MARKED WITH "I• ARE PROVIDED WITH A MASTER MULTI-LAMP BALLAST. 2. FIXTURES MARKED "2" AND ABOVE ARE ME-WIRED TO THE MASTER MULTI-LAMP BALLAST. 3. FOR CLARITY, FACTORY PRE - WIRING IS NOT INDICATED ON LIGHTING PLAN. 4. FOR MORE INFORMATION , CONTACT ELGEE ELECTRIC AT' (BOO) 244 -0947. FLUORESCENT WIRING DETAIL NTS VAV. LIGHT /RECEPTACLE ELECTRICAL CONNECTION BOX TO BE LOCATED ABOVE CRUNG� PENDANT LIGHTING, REFER r- TO REFLECTED CEILING. PLAN ALIGN EDGE OF SORTING FIXTURE W/ TOP OF PRE - FINISHED CABINET VALANCE AS SHORN.. (ROOF OR FLOOR ABOVE BLDG. STRUCTURE SWITCH CONDUIT FIXTURE. LAMP. RECEPTACLE AND SNITCH FURNISHED BY ESP. Or INSTALLED BY ELECTRICAL CONTRACTOR. 3 /4 " COADUIT TO 120 CULT CIRCUIT. SEE FLOOR PLANS FOR CIRCUIT NUMBER. SECTION NEVI CTRICAL WIRING CUT -OUT IN MILLWORK. ELECTRIC OUTLET(S) FURNISHED AND INSTALLED IN CASH WRAP. WIRED BY ELECTRICAL CONTRACTOR. xIQLE METAWC CONDUIT FOR 1 AI 3 --- CONDUIT STUB -UPS 1" AF.F.(TYP) NOTE. 21 CR MORE SPEAKERS - CONNECT TO AMPLIFIER OUTPUT (CONNECT AMPLIFIER 70 TAPE DECK) NOTE LESS THAN 21 SPEAKERS - CONNECT DIRECTLY TO PRO -PAC MODEL MC1025 TAPE DECK OUTPUT RED 1 EAI(ER OUTPUT � TERMINALS a& 111111MMIlk AWN, RI RI • AIL AIIL CENTERED IN 1 QUAD. RECEPT. (TYP 4) EACH CONTAINING CABINET.(TYP) , AN ISOLATED GROUND DUPLEX RECEPTACLE AND A UTILITY DUPLEX POWER RECEPTACLE. FLEXIBLE METALLIC CONDUIT FOR UTILITY POWER (TYP.) TD ADDITIONAL SPEAKERS (AS 8870.) FIELD VEMFY #18 MIR MISTED PR PLENUM RATED BB ATRI 40. NEST PENN 25224 OR E CG: E BY E0.. LS.P. TO FUNK. FIRE CAN ENCLOSURES FBI SPKRS OF REDO BY CODE). TUBE TO BE COLOR CODED TO FACILITATE MAINTENANCE OF PROPER PHASN0. SEE NOTE. III S F O CASH VF.2AP COUNTER -■ =E_■- _ -0■1. TWO 1" CONDUIT STUB -UPS FOR DATA CABLE ()ELEVATION B NTS ELEVATION NTS 70 SPEAKER NNE NOTE CASSETTE DECK TO BE LOCATED ON SHELF ABOVE MANAGER'S DES(. STUB 3/4" CONCUR FRCS JUNCTION BOX AT BB" A.F.F. TO JUST MOW CEILING. SEE POLAR COOED NOTE • Q ON SHEET E1. SPEAKER WIRING DIAGRAM LEXIBLE METALLIC CONDUIT FOR ISOLATED POWER (TYP.) NO' THE CONNBN (BLACK)'NRE IS PPE- SOIAEREO TO THE NECAIWE TERMINAL POSITIVE CONNECT THE THE I j R M TO THE .5 WATT TM AND TO THE POSRYE TERMINAL OF THE IETRRNAL.SRNIP. ASPIRE LUC IS FRONDED TO CONNECT THE TAP CURE 70 THE POSITIVE TERMINAL CUTOFF AU- BARE ENDS OF UNUSED TAP TARES AND INSULATE NTH ELECTRICAL TAPE TO AYU10 CONTACT NTH METAL SURFACES WM NAY CAUSE A SNORT IN THE SPEAKER UNE CONNECT THE SPEAKER DIRE TO THE 70V. RED LEAD OF THE TRANSFORMER CORRESPONDING TO THE RED LEAD OF THE SPEAKER DIRE AND THE COMMON BLACK LEAD OF THE TRANSFORMER 70 THE COHRESPOUDING BLACK'. LEAD OF THE SPEAKER DIRE NTS (REFER TO ARCHITECTURALS FOR SPEAKER LOCATIONS) COLOR COLE XEY FOR TAP TARES: GREEN 0.25 WATT TAP (NOT USED) D WATT TAP OT U SIM ON WATT T P (BATH k BODY YORKS) YELLO WA TT TAP OT U SED BLUE 2 WATT TAP OT USED BROWN SD !V7T VAV BOX VAV BOX 61 WINO COMI/LNXrtNO BOARD mom N cu. WN4ON sImm KW Ma ) I a WEIRS MAY 18 2001 O uJ co 6 z C� z z Cl_ CY T / 1 -GII 011120 SHEET ED.1 0 W LLI I— 3 Ne CC C a OD ' re WW o 3 W WO) O� G 13_ 7C he N M he m O. r I— z ELECTRICAL RESPONSIBILITY SCHEDULE ITEM FURNISHED BY INSTALLED BY R —USE EXISTING REMARKS ELEC. CON LANDLORD LIMITED STORE PLANNING INC. OTHERS GNOTONYT 'TANGO '3313 OTHERS CARRIER MAIN OVERCURRENT DEVICE IN LANDLORD'S ELECTRIC ROOM • 21.700 • 27.125 SHOW VANDOW LIGHTING ALLOWANCE SEE MIE11 ••R INS •WEr METER IN LANDLORD'S ELECTRIC ROOM _ _ -- 2800" 1.25 2.600 • e¢ PDER ••D 11S MEET C/T'S IN LANDLORD'S ELECTRIC ROOM 7.131 7.131 Lo tack 0.6 REY NNINO NW 7.131 OTORS • C/T CABINET IN LANDLORD'S ELECTRIC ROOM ____ _ t +2SxLAROEST _ ___ XED ACE ELECTRIC • SERVICE ENTRANCE CONDUIT(S) TO LEASE SPACE • 35.899 • • 37.428 AI CONDITIONING s¢ vo•R 1m 118 err SERVICE ENTRANCE FEEDER(S) TO LEASE SPACE 31.163 31.163 • • 33.033 LE CONC WATER EATER SEE 10°I MEP TR •¢T 277/480 VOLT DISCONNECT SWITCHE(S)/PANELS 1,500 1.500 S 1.500 SCELLANEOUS C es ar OF �ACKAIED STEP -DOVM TRANSFORMERS AND MOUNTING ACCESSORIES (AS REQUIRED) 6.756 6.756 • 8.756 TOTAL ND/a • USE GREATER •• N.EC. ARTICLE FOOT OF SHOW SHOW WINDOW NEC. RFMANn aOMPCMIROT RFPAaGam n LNa 120/208 VOLT PANEL(S)/DISCONNECT SWITCH(ES) 67.824 75.588 • 82.538 VALUE OF THE 220-12 REQUIREMENT WINDOW) MINUS LIGHTING VA KVA 11 LLjj 1 'C .1 wsoxam Cr exFSAarA•p IR UM DISCONNECT SNITCH(ES) AND /OR MANUAL MOTOR STARTER(S) SYSTEM VOLTAGE 152.521. x d2 99 AMPS • TR ACK PENDANT LIGHT SAC 05091- IN10 -CL -TR U 72 VMITE CORD do TRACK ADAPTER HAH SOPAR20/HJNFL LAMP METER IN LEASE SPACE TRACK LTS. OW COG. MID. DEMO AREA PENDANT ABOU • RWI35 • & T2GAL STEM BRIM 1000 40 LAMP S • C/YS IN LEASE SPACE CAPRI PC1501P- MOD -6 WITH 90PAR/H/FL LAMP MOUN AT 10 -0 AF.F. LSP. INC. 1.620 0.544 © PENDANT UGHT • C/T CABINET IN LEASE SPACE MME • • BEAM MOUNTED PENDANT LIGHT ■■■ LSP. INC, • 0. UGHTING FIXTURES AND LAMPS TOILET EXHAUST FAN(S) LSP. INC. • U • • ABOUT '$PL- AD132PL -GAL & ST24GAL STEM NTH F32TBX /SPX27 /4 - P LAMP ELEC. Wnx RECEPTACLES: SALES AREA V • • L.P. INC. 39 ® RECEPTACLES NON -SALES AREA CP R4X N RP DJU WITH ARI SOPAR20/H/F LAAMP STABLE TRIM • • O PENDANT LIGHT ABGJTE RCS 200NHT/BC800 3/4 MHT/SAM1 3 ANT NTH 1501 135WM LAM MOUNTED AT 8' -9 A F POWER WRING TO HVAC EQUIPMENT CONTACTOR LIGHTING CONTACTOR FOR -��.a r WING CONTROL SYSTEM • 11• • 11111111111 • ABGJTE • A62100 /135 /G & CURVED STEM WITH 1SOA/135WM LAMP LSP, INC. • 0 ® ��L HA AZ-6 RING •I-2717P• WHIT NTH LO /C/NFL (EXZC) LAMP , 0 rater MEM t t_ POWER WRING TO • CASHWRAP • - - �a = "QVV�yy HIGH -UTES EDGE UTE 1BP- RXFO -2 -RC• WITH BATTERY PACK (SALES AREA ONLY) RY PACK U LSP. INC. . Gam® POWER WRING AND CONDUIT FOR SENSORMATC EQUIPMENT W POWER WIRING FOR RONG GRILLE A (SALES AREA ONLY • liii EXIT/EMERG. LIGHT HIGH -LIOES S-R-D WI BATTER ADJUSTABLElla; 5 (NON - AREA ONY LY) PACK & DELIVERY BUZZER SYSTEM .4....P(1.1 • • LSP. INC. • ® TELEPHONE OUTLETS AND CONDUITS NTH PULLWIRE • LSP. INC. CONTR. • ® CEILING EXHAUST FAN GC160, 120 VOLT, 1 PHASE, 115 WATTS DATA OUTLETS AND CONDUITS NTH PULLWRE • ,-r-I • DURAY MASTER 4 LAMP EOH11171208417 DURAY MASTER 2 LA MP EOHti7 77 208 217 LSP. INC TELEPHONE CABLING S INGLE TUBE FLUOR. - MASTER • LSP. INC. • 1 • i 4NG.E VIBE FLUOR. - M DATA CABUNG LS.P. INC. • I--E -1 • DURAY SATEUTE 1 LAMP EQ1117NB LS.P. INC. TELEPHONE BOARD I Y i • • LS.P. INC. • ar4execrr Of n1EPAIXAIO n u1R DUCT MOUNTED SMOKE DETECTORS DURAY SATELITE • LAMP EQ1132NB S • 2 LAMP STAGGERED FLUOR. STRIP DURAY • SNL -232 NTH (2) F2578/SP30, 012 F32TB/SP30 LAMPS LB a LESS BALLAST (AS FIRE ALARM SYSTE ~� FLUOR. STRIP OR 2 )) REQUIRED) F32T8/SP30LAMPS LB LESS BALLAST 4(AS 2 REQUIRED) L.P. INC., • MUSIC SYSTEM /SPEAKERS /CABINET DUPLEX ERPL RECEP7. W/ COV ATE • • QUAD. OVE REC E W/ C MUSIC SYSTEM WRING • • DIMMER SWITCH LUTRON C- 2000- MH/DIMMER 2000 WATT LSP. INC. TEMPERATURE CONTROL SYSTEM CONDUIT • TELEPHONE OU TLET • LSP. INC. • Na AHU, ACTS, RTU AND /OR VAV SERVICE UGHTNG SNITCH & RECEPTACLE IVORY GROMMETED CVRPLT.IN SALES AREA & WHITE GROMMETED IN NON -SALES AREA SEE FLOOR PLAN FOR MOUNTING HEIGHT • • Res M ucH OTI r ON sNI SETCH NSOR INSTALLED AT 48• A.F.F. ELECTRIC LOAD SUMMARY SYSTEM85V DESCRIPTION CONNECTED KW/KVA F DR s .E CONNECTED KW - VA N.E.C. DEMAND FACTOR N.E.C DEMAND KVA 0111150 16.538 1.0 18.538 21.700 1.25 27.125 SHOW VANDOW LIGHTING ALLOWANCE - - -- -- _ _ -- 2800" 1.25 2.600 ' ECEPTACLES 7.131 1.0 7.131 7.131 Lo tack 0.6 REY NNINO NW 7.131 OTORS ____ 0,9 ____ _ t +2SxLAROEST _ ___ XED ACE ELECTRIC 35.899 • 1.0 35.899 35.899 • . 37.428 AI CONDITIONING 31.183 • 1.0 31.163 31.163 • La +25x LARGEST 33.033 LE CONC WATER EATER 1.500 LO 1,500 1.500 1.0 1.500 SCELLANEOUS 8.756 1.0 6.756 6.756 1.0 8.756 TOTAL ND/a • USE GREATER •• N.EC. ARTICLE FOOT OF SHOW SHOW WINDOW NEC. RFMANn 67.824 TWO CATEGORIES ACTUAL :1iNIMUM 67.824 75.588 USE 100 AMP SERVICE 82.538 VALUE OF THE 220-12 REQUIREMENT WINDOW) MINUS LIGHTING VA KVA 11 LLjj 1 'C .1 (200VA PER INSTALLED FEEDER AMPERAGE D RECESSED ONNUGHT SYSTEM VOLTAGE 152.521. x d2 99 AMPS 480 x 1.732 TRANSFORMER LOAD SUMMARY 10 ,� V DESCRIPTION ACTUAL CONNECTED KW/KVA POLAR FACTOR ACTUAL DEMAND KVA N.E.C. CONNECTED KW/KVA N.E.C. DEMAND FACTOR N.E.C. DEMAND KVA LIGHTING 16.538 1.0 16.538 21.700 1.25 27.125 RECEPTACLES 7.131 1.0 7.131 7.131 .0 T 0.5 7 RDINNWO GOO KW 7.131 MOTORS ____ 0,9 LS.P. INC DOM&IGHTS COWL IGNT5 PENDANT LIS 1 •-25X LAMEST DT OHNUGH J. FIXED ELECTRIC SPACE HEATING - - -- • 1,0 ____ ____ • +2Sx1LIRC6f LSP. INC AIR CONDITIONING SYSTEM ____ • 1 0 ABOUTE • AD100/135GG • WITH 150A/135WM LAMP • 7.0 +25x G ELECTRIC WATER HEATER 1 1.0 1.500 1.500 1.0 1.500 MISCELLANEOUS 0,230 1.0 0.230 0.230 1.0 0.230 TOTAL BONS • USE GREATER 25.399 1150 CATEGORIES 25.999 30.561 USE 45 KVA. TRANSFORMER .35.986 VALUE OF THE L SP. INC. ELECTRICAL FIXTURE I URE S RULE M45 SYMBOL DESCRIPTION MANUFACTURER & MODEL NUMBER FURN.BY NLC KW BM Opts CAPRI R9X HOUSING & RMS40 CLEAR TRIM WITH 90 PAR/H/FL LAMP LSP. INC. CASH REGISTERS CAPRI R9OX HOUSING & RMS40 CLEAR TRW H 90 PAR/H/FL LAMP 'CH LSP. INC C.) PENDANT LIGHT ILLUMATG EXPERIENCE 1-E : '3CB -30 STEM WITH 15 LAMP LS.P. INC • p TRACK LIGHT LUMIERE 0299 W M TIi 50PAR30 /HIR/FI25 HITE LAM LS.P. INC DOM&IGHTS COWL IGNT5 PENDANT LIS EO� O DT OHNUGH J. TR SP SOMR18/G/1 N & P A PHVS5O/75WH ADJUSTABLE JMOMTH LS.P. IN C ' Y PENDANT UGHT ABOLI7E 0A/ LAMP 0/135CGN• & STIOWIHT STEM NITH 15 LSP. INC F . PENDANT LIGHT ABOUTE • AD100/135GG • WITH 150A/135WM LAMP LS.P. INC G PENDANT LIGHT WITH 1 E • RWIMOOG LA • & 72• MITE CORD WITH 150A/135WM LAMP LSP. INC 1,050 1.050 0 ® D N AUJ. NAF R9OA /H/FL LAMP ADLS156 CLEAR AD.RJSTABLE TRIM LSP. INC, ag O C MOUNTED UP EI LIGHT TO BE DETERMINED LS.P. INC. • O WA SCOLL NCE MOUNTED REJW559 SCONCE UGHT W /2 -ILL85 WHITE BELL GLOBES LSP. INC © TRACK LIGHT HALO GIMBAL RIN • G 1_17.38P• 66TH 90PA T/FL LAM 38P• WHITE L SP. INC. M RECESSED DONNLIGHT UGHTOUER 7132BG120 AND 8037CLW CLEAR TRIM WITH F327BX/SBX27 /4P LAMP L.P. INC O D RECESSED ONNUGHT CAPRI R4X HOUSING & R402SP TRIM WITH 50PAR20/H/NFL LAMP LS.P. INC TR ACK PENDANT LIGHT SAC 05091- IN10 -CL -TR U 72 VMITE CORD do TRACK ADAPTER HAH SOPAR20/HJNFL LAMP LSP. INC. LSP. INC. TRACK LTS. OW COG. MID. DEMO AREA PENDANT ABOU • RWI35 • & T2GAL STEM BRIM 1000 40 LAMP S © PENDANT LIGHT P CAPRI PC1501P- MOD -6 WITH 90PAR/H/FL LAMP MOUN AT 10 -0 AF.F. LSP. INC. 1.620 0.544 © PENDANT UGHT :04F321BX/SPX27 LAMPOU• N ST10.41 STEM L.P. INC. O BEAM MOUNTED PENDANT LIGHT 15GAL• & '2" '2" STEM CHOOSE •AD0 /3 WITH 150A/135 LAMP LSP. INC, BERG.M.L' BERG./N.L. S 0. BEAM MOULIGHT NTED PENDANT ABOIJTE •• AD100 /135GAL NTH 150A/135WT1 LAMP LSP. INC. U BEAM MOUNTED PENDANT LIGHT ABOUT '$PL- AD132PL -GAL & ST24GAL STEM NTH F32TBX /SPX27 /4 - P LAMP LSP. INC. V WALL MOUNTED SCONCE REJWI51 POUSHED NICKEL WALL SCONCE W/75W LAMP L.P. INC. 39 ® MINI RECSED ADJ. DOWNUGH 7 CP R4X N RP DJU WITH ARI SOPAR20/H/F LAAMP STABLE TRIM L.P. INC. B O PENDANT LIGHT ABGJTE RCS 200NHT/BC800 3/4 MHT/SAM1 3 ANT NTH 1501 135WM LAM MOUNTED AT 8' -9 A F L.P. INC. Y STOREFRONT BILLBOARD LIGHT ABGJTE • A62100 /135 /G & CURVED STEM WITH 1SOA/135WM LAMP LSP, INC. • 0 ® TRACK LIGHT HA AZ-6 RING •I-2717P• WHIT NTH LO /C/NFL (EXZC) LAMP LS.P. SP. INC. • = EXIT LIGHT HIGH -UTES EDGE UTE 1BP- RXFO -2 -RC• WITH BATTERY PACK (SALES AREA ONLY) RY PACK U LSP. INC. . Gam® EMERG. UGHT LSP. INC. A (SALES AREA ONLY • &® EXIT/EMERG. LIGHT HIGH -LIOES S-R-D WI BATTER ADJUSTABLElla; 5 (NON - AREA ONY LY) PACK & LSP. INC. • .4....P(1.1 EMERG. LIGHT AD STALE HEADS (NON BSALESYAREAOtONLY) LSP. INC. • ® SPEAKERS SPEAKERS FURN'D. BY LSP. -18 GA. MRE (AND FIRE RATED ENCLOSURES & CONDUIT IF REQUIRED BY LOCAL CODE) BY E.C. LSP. INC. CONTR. • ® CEILING EXHAUST FAN GC160, 120 VOLT, 1 PHASE, 115 WATTS LS.P. INC. • ,-r-I SINGLE FLUOR._A1 A SIER DURAY MASTER 4 LAMP EOH11171208417 DURAY MASTER 2 LA MP EOHti7 77 208 217 LSP. INC I J, ' S INGLE TUBE FLUOR. - MASTER DURAY MASTER 4 LAMP EON11251208425 DURAY MASTER 2 LAMP EgIt125720B2Z5 LSP. INC. • 1 • i 4NG.E VIBE FLUOR. - M DURAY MASTER 4 LAIiP FOH11321208432 DURAY MASTER 2 LAMP EGH7132120B232 LS.P. INC. • I--E -1 SINGLE TUBE FLUOR. -SLAVE DURAY SATEUTE 1 LAMP EQ1117NB LS.P. INC. I Y i SINGLE VIBE PLUOB,_ DURAY SAIELITE 1 LA E0 1725NB LS.P. INC. • F =N SINGLE VIBE FLUOR. -SLAVE DURAY SATELITE • LAMP EQ1132NB LSP. INC. I --I I-1 2 LAMP STAGGERED FLUOR. STRIP DURAY • SNL -232 NTH (2) F2578/SP30, 012 F32TB/SP30 LAMPS LB a LESS BALLAST (AS LS.P. INC. ~� FLUOR. STRIP OR 2 )) REQUIRED) F32T8/SP30LAMPS LB LESS BALLAST 4(AS 2 REQUIRED) L.P. INC., • ti �v DUPLEX ERPL RECEP7. W/ COV ATE 20 AMP, 120 VOLT LS.P. INC. QUAD. OVE REC E W/ C 20 AMP, 120 VOLT LS.P. INC. 0 DIMMER SWITCH LUTRON C- 2000- MH/DIMMER 2000 WATT LSP. INC. . N , TELEPHONE OU TLET IVORY RJ14C TELE. JACK IN SALES AREA & MITE RJ14C TELE. JACK IN NON -SALES AREA SEE FLOOR PLAN FOR MTG. HOT. LSP. INC. • Na COMPUTER OU TLET IVORY GROMMETED CVRPLT.IN SALES AREA & WHITE GROMMETED IN NON -SALES AREA SEE FLOOR PLAN FOR MOUNTING HEIGHT Lap " • Res M ucH OTI r ON sNI SETCH NSOR INSTALLED AT 48• A.F.F. LS.P. INC. • 0 JUNCTION BOX JUNCTION BOX 4• x 4" x 2 i /8• DEEP MINIMUM LS.P. INC. MANUAL MOTOR S7AROER NEMA 1 ENCLOSURE LS.P. INC. tia MAGNETIC STARTER MLTINIMUM STARTER IN A NEMA 1 ENCLOSURE, FSIU VOAGE ZE LL 1 L.S.P. INC. • c DISCONNECT SNITCH HEAVY-DUTY, FUSIBLE & NON- FUSIBLE LSP. INC. • Or DELIVERY BUZZER SEE FLOOR PLAN FOR MOUNTING HEIGHT L.P. INC. • ® DELIVERY AJSFORM BUER ZZER 7R TRANSFORMER AT 8' -0 A.F.F. LSP. INC. • 0 DELIVERY BUZZER PUSHBUTTON PUSHBUTTON UNIT AT 54• A.F. F. LSP. INC. CEILING SMOKE DETECTOR SYSTEM CONNECTED CEIUNG MOUNTED IONIZATION TYPE SMOKE DETECTOR SEE RESPNS SCHEDULE X O DUCT MOUNTED SMOKE DETECTOR SYSTEM CONNECTED DUCT MOUNTED IONIZATION TYPE SMOKE DETECTOR COMPL BTH SAMPLING TUBES SEE RESPNS SCHEDULE FIRE ALARM SIGNAL SYSTEM RECESSED RECESD VISUAL UNIT AT 8' -0 AF.F SEE RESPNE SCHEDULE 0 FIRE RM PULL ALA STATION SYSTEM CONNECTED DOUBLE ACTION MANUAL FIRE ALARM PULL STATION AT 48' AF.F. SEE RESPNS SCH EDULE m FIRE ALARM SIGNAL SYSTEM CONNECTED RECESSED AUDIOVISUAL UNIT AT B' -0 A.F.F. SEE RESPNE SCHEDULE ® SINGLE PHASE MOTOR SEE CODED NOTES ® 1HREE PHASE MO70R SEE CODED © G LI CONTA GHTIN CTOR E N LECTRICALL ENEROZ ED AND HEW UGHTNG CONTACTOR I NEMA 1 LSP. INC, ® TIME CLOCK 7 -DAY MME CLOCK LS.P. IN,. . O DUPLEX FLOOR RECEP7 WITH COVERPLATE 20A AMP, 120 VOLT LSP, INC. ® QUAD. FLOOR RECEPTACLE NTH COVERPLATE 20A AMP, 120 VOLT LSP. INC. • • DENOTES CUSTOM LENGTH. REFER TO ARCHITECTURAL REFLECTIVE CEILING PLAN FOR LENGTH. NOTE: ® FIELD ADJUST LAMP, AFTER FIXTURE IS INSTALLED. TO A 45' ANGLE FROM VERTICAL PERPENDICUANAGLAR R. TO ( FACING) C O AB F ALL •E• & •H INETS OR AS • DIRFI S). BY UNITED STORE PLANNING PROJECT M 0 SEE TRACK ATTACHMENT DETAIL ON SHEET ED /1. TRACK IS SHIPPED IN 12' LENGTHS. USE THESE 12' LENGTHS WHEREVER POSSIBLE. AVOID THE USE OF SEVERAL SMALL LENGTHS IN A SINGLE RUN OF TRACK, ® FIELD ADJUST LAMPS AFTER FIXTURE IS. INSTALLED TO ILLUMINATE EGRESS PATH. COORDINATE AIMING MTH UNITED STORE PLANNING PROJECT MANAGER. TOP VIEW FRONT ELEVATION ° o 01 o 01 o • SWITCHBOARD NOTES Pow -R -LINE C FRONT. ACCESS/ FRONT -REAR ALIGNED SERVICE VOLTAGE: 480/277 3 PHASE 4 WIRE MAIN SUS: 1 CC AMP NEUTRAL BUS: 100 AMP BUS MATERIAL: COPPER MAIN LUGS: 1- #1 PER PHASE AND NEUTRAL GROUND LUG: SUPPLIED AS STANDARD STANDARD INTERRUPTING RATING: 65 KAIC @D 4130 VOLT SUITABLE FOR USE AS SERVICE ENTRANCE EQUIPMENT SWITCHBOARD CONSTRUCTION MEETS UL -1391 NEMA 1 ENCLOSURE FINISH: ANSI-61 C.T..S SIZED FOR 1 CC AMP FULL LOAD. GENERAL CONTRACTOR NOTES 1 . NO NEW EQUIPMENT IS TO BE USED FOR TEMPORARY POWER DURING THE CONSTRUCTION PHASE WITHOUT THE WRITTEN APPROVAL OF WR CONTROLS. ELECTRICAL CONTRACTOR NOTES 1. SWITCHBOARD WILL SHIP IN TWO 121 VERTICAL SECTIONS. SEE SHIPPING SPLITS BELOW. NOTE THAT SWITCHBOARD WILL SHIP ON AN ENCLOSED SEMI- TRAILER. E.C. MUST ARRANGE FORA FORK LIFT TO UNLOAD AT JOB SITE. E.C. WILL RECEIVE 24 HOUR NOTICE PRIOR TO DELIVERY. 2. PROPERLY SIZED CONDUCTORS WILL BE TERMINATED AT PANEL A'S MAIN BREAKER AND COILED UP INSIDE OF SECTION 2. E.C. IS RESPONSIBLE TO CONNECT THESE CONDUCTORS TO TRANSFORMER SECONDARY LUGS. SHIPPING sauT FOR QUESTIONS REGARDING THI5 EWITCHGEAR CONTACT WR CONTROLS @ 1 -8O0-417 - 7543 AT-N: JEFF FACTOR B PREPACKAGED ELECTRIC SERVICE EQUIPMENT DETAIL NTS POWER RISER DIAGRAM GENERAL NOTES HVAC CIRCUIT BREAKERS SHALL BE • HACK • TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER NEC. 2. ELECTRICAL CONTRACTOR SI1ALL HEIM VERIFY EXACT K,AI.C. RATING OF LANDLORDS DISTRIBUTION EQUIPMENT. FURNISH AND INSTALL UNITED STORE PLANNING SYSTEM TO MATCH. 3. ELECTRICAL CONTRACTOR SMALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO 7% BETWEEN PHASES: A/B, B/C AND A/C AS INDICATED ON PANEL WRING SCHEDULES. 4, PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.EC. FIELD NERVY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. 5. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTOR SYSTEM. 6. CONTRACTOR SHALL FURNISH AND INSTALL A TYPEWRITTEN DIRECTORY CARD OF THE CIRCUITS AND PLACE IN PANEL DOOR. EXISTING ELECTRICAL METER - TENANT E.C. TO FURNISH AND INSTALL IOGA SCONNECT SW. AND 100A /3P FUSES TENANT E.C. TO RUN 4 411 THHN & 1 ie MD. IN 2• CONDUIT. RiG -1: 480V. 30, 27.2 F.LA., 18.5 KW. HEAT B D 40A/3, H BRESERSW. AT UNIT 4 /12 THHN & 1 412 SP' IN 3/4 CONDUIT 10 AMP MLO 480 /277 MOP Rill -2.• 460V, 30, 16 F.LA, , KW HEAT 3OA NON- POISED WP DISC. SW. A 10 6 T UNIT TO 25A/3P HAOR BREAKS VAV -2:. 480V, 30, 6 KW HEAT NTH 277V. 10, 1/4 HP MOTOR. INTEGRAL DISC. SW. TO 20A /3P BREAKER LANDLORDS ELECTRICAL DISTRIBUTION, 277/460V, 30, 4 PREPACKAGE ELECTRICAL SERVICE EQUIPMENT ELEVATION (IFS UNIT) NTS _ LANDLORD I BATH &.BO WORKS r 3 de THHN at 1 PO MD. IN I CONDUIT "....._____P 4 41 7HHN & 1 J R GOD. IN 2 CONDUIT n(10( A POWER RISER DIAGRAM Noel Mktg Soheelli® (261PII.56) Pandboard A Voltage 120/208 Phase 3 Nre 4 AC Rating 65,000 Panel Type CUTLER HARMER Mains 150A MCB Mans Rating 225 AMP NEMA Type Enclosure 1 Mounting IFS UNIT Options - Note VERIFY Notes • NI circuit bred•re to be 20 -Amp, 1-Pole unless othenNe noted N.E.C. Wad Totals OA 10.273• ACTUAL Connected- IoldWH 8.48319 ea ___12,8_1•82 eB 8.592 SC 10.4281n eC 8,324 i• T1He 38.581 ke Told 25.39919 (AO Phases to be balanced to *thin 7. using Ackd load Totals.) ELECTRICAL EQUIPMENT PROVIDED BY LSP CONDUIT RUNS W/PULL STRINGS FOR EQUIPMENT PROVIDED AND INSTALLED BY EC ELECTRIC TROUGH PROVIDED AND INSTALLED BY E �J GC TO PROVIDE AND INSTALL 12 PLYWOOD SURFACE MOUNTED TO WALL LOCATION (TIP.) ON RIGHT SIDE OF ELECTRIC EQUIPMENT. W R. CONTROLS TELEPHONE EQUIPMENT II ELECTRICAL EQUIPMENT &I S 0etknx: AS - Pawwlhlk AS Bredler Ln - Handle lock-off dance ST - Shunt Trip 11pe NI% - Ausll11 C8ntaak PA - Hance Padodk Attachment SEQ - Ground Fait Circuit Interrupter HACB - Heating, A/C 6 Refrigeration IMES- CO WI G C - SALESMG C - SALES CONDUIT FROM MA ELECTRIC ROOM BY LL EC TROUGH DEMARK 1 PROVIDED PHONE CO. . BY TELEPHONE EQUIPMENT BOARD PROVIDED BY THOMAS ELECTRONICS. INSTALLED BY SPENCERS LG.. '•a SIDE MEW FLOOR 0 Li H- U CD z z z 0 0 F- 3 i CK cc < IJJ a. YZ co 3 CC U. NJ co 3 CCCZC C D W W O) !p cn J 3C he N CC < < M he m a r 011120 SHEET ED.2 ELECTRICAL SCHEDULE; THREE LIMITED PARKWAY COLUMBUS, OHIO 43230 614-415-7000 la DRAW. 01112004.0*g DATE: MAY 17, 2C01 Zane Load Deeortlkn NLC KW BM Opts She Load Deealptkn CASH REGISTERS 1.400 DOWtI GHTS CASH REGISTERS UTILITY POKER 1.050 1.080 DOM&IGHTS COWL IGNT5 PENDANT LIS SOLOED SYSTEM OBBUTER 1.200 1.200 PENDANT LTS TRACK LTS. CONTROLS TELEPHONE 1,050 1.050 TRACK LTS. 00 ag aO �I'l DRAIN PIN 1.500 TRACK LOS. ELEC. KR. HTR. BACKIRAP 1.700 0.900 TRACI( LOS. TRACK LTS TRACK LOS. RECEPTACLES RECEPTACLES 1,200 1.200 TRACK LTS. RECEPTACLES RFCJ:PTACLES 1.620 0.544 506 .IGHTs DOANLIGHTS FLUORESCENTS BERG.M.L' BERG./N.L. S 1.350 0.352 NON-SALES SHARON OUR LAV SPARE 0.584 1.700 WINDOW LTS. 39 SPARE SPAS - - B - 1.200 - SIGN SPARE 40 41 SPARE - - C - - SPARE 42 TOP VIEW FRONT ELEVATION ° o 01 o 01 o • SWITCHBOARD NOTES Pow -R -LINE C FRONT. ACCESS/ FRONT -REAR ALIGNED SERVICE VOLTAGE: 480/277 3 PHASE 4 WIRE MAIN SUS: 1 CC AMP NEUTRAL BUS: 100 AMP BUS MATERIAL: COPPER MAIN LUGS: 1- #1 PER PHASE AND NEUTRAL GROUND LUG: SUPPLIED AS STANDARD STANDARD INTERRUPTING RATING: 65 KAIC @D 4130 VOLT SUITABLE FOR USE AS SERVICE ENTRANCE EQUIPMENT SWITCHBOARD CONSTRUCTION MEETS UL -1391 NEMA 1 ENCLOSURE FINISH: ANSI-61 C.T..S SIZED FOR 1 CC AMP FULL LOAD. GENERAL CONTRACTOR NOTES 1 . NO NEW EQUIPMENT IS TO BE USED FOR TEMPORARY POWER DURING THE CONSTRUCTION PHASE WITHOUT THE WRITTEN APPROVAL OF WR CONTROLS. ELECTRICAL CONTRACTOR NOTES 1. SWITCHBOARD WILL SHIP IN TWO 121 VERTICAL SECTIONS. SEE SHIPPING SPLITS BELOW. NOTE THAT SWITCHBOARD WILL SHIP ON AN ENCLOSED SEMI- TRAILER. E.C. MUST ARRANGE FORA FORK LIFT TO UNLOAD AT JOB SITE. E.C. WILL RECEIVE 24 HOUR NOTICE PRIOR TO DELIVERY. 2. PROPERLY SIZED CONDUCTORS WILL BE TERMINATED AT PANEL A'S MAIN BREAKER AND COILED UP INSIDE OF SECTION 2. E.C. IS RESPONSIBLE TO CONNECT THESE CONDUCTORS TO TRANSFORMER SECONDARY LUGS. SHIPPING sauT FOR QUESTIONS REGARDING THI5 EWITCHGEAR CONTACT WR CONTROLS @ 1 -8O0-417 - 7543 AT-N: JEFF FACTOR B PREPACKAGED ELECTRIC SERVICE EQUIPMENT DETAIL NTS POWER RISER DIAGRAM GENERAL NOTES HVAC CIRCUIT BREAKERS SHALL BE • HACK • TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER NEC. 2. ELECTRICAL CONTRACTOR SI1ALL HEIM VERIFY EXACT K,AI.C. RATING OF LANDLORDS DISTRIBUTION EQUIPMENT. FURNISH AND INSTALL UNITED STORE PLANNING SYSTEM TO MATCH. 3. ELECTRICAL CONTRACTOR SMALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO 7% BETWEEN PHASES: A/B, B/C AND A/C AS INDICATED ON PANEL WRING SCHEDULES. 4, PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.EC. FIELD NERVY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. 5. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTOR SYSTEM. 6. CONTRACTOR SHALL FURNISH AND INSTALL A TYPEWRITTEN DIRECTORY CARD OF THE CIRCUITS AND PLACE IN PANEL DOOR. EXISTING ELECTRICAL METER - TENANT E.C. TO FURNISH AND INSTALL IOGA SCONNECT SW. AND 100A /3P FUSES TENANT E.C. TO RUN 4 411 THHN & 1 ie MD. IN 2• CONDUIT. RiG -1: 480V. 30, 27.2 F.LA., 18.5 KW. HEAT B D 40A/3, H BRESERSW. AT UNIT 4 /12 THHN & 1 412 SP' IN 3/4 CONDUIT 10 AMP MLO 480 /277 MOP Rill -2.• 460V, 30, 16 F.LA, , KW HEAT 3OA NON- POISED WP DISC. SW. A 10 6 T UNIT TO 25A/3P HAOR BREAKS VAV -2:. 480V, 30, 6 KW HEAT NTH 277V. 10, 1/4 HP MOTOR. INTEGRAL DISC. SW. TO 20A /3P BREAKER LANDLORDS ELECTRICAL DISTRIBUTION, 277/460V, 30, 4 PREPACKAGE ELECTRICAL SERVICE EQUIPMENT ELEVATION (IFS UNIT) NTS _ LANDLORD I BATH &.BO WORKS r 3 de THHN at 1 PO MD. IN I CONDUIT "....._____P 4 41 7HHN & 1 J R GOD. IN 2 CONDUIT n(10( A POWER RISER DIAGRAM Noel Mktg Soheelli® (261PII.56) Pandboard A Voltage 120/208 Phase 3 Nre 4 AC Rating 65,000 Panel Type CUTLER HARMER Mains 150A MCB Mans Rating 225 AMP NEMA Type Enclosure 1 Mounting IFS UNIT Options - Note VERIFY Notes • NI circuit bred•re to be 20 -Amp, 1-Pole unless othenNe noted N.E.C. Wad Totals OA 10.273• ACTUAL Connected- IoldWH 8.48319 ea ___12,8_1•82 eB 8.592 SC 10.4281n eC 8,324 i• T1He 38.581 ke Told 25.39919 (AO Phases to be balanced to *thin 7. using Ackd load Totals.) ELECTRICAL EQUIPMENT PROVIDED BY LSP CONDUIT RUNS W/PULL STRINGS FOR EQUIPMENT PROVIDED AND INSTALLED BY EC ELECTRIC TROUGH PROVIDED AND INSTALLED BY E �J GC TO PROVIDE AND INSTALL 12 PLYWOOD SURFACE MOUNTED TO WALL LOCATION (TIP.) ON RIGHT SIDE OF ELECTRIC EQUIPMENT. W R. CONTROLS TELEPHONE EQUIPMENT II ELECTRICAL EQUIPMENT &I S 0etknx: AS - Pawwlhlk AS Bredler Ln - Handle lock-off dance ST - Shunt Trip 11pe NI% - Ausll11 C8ntaak PA - Hance Padodk Attachment SEQ - Ground Fait Circuit Interrupter HACB - Heating, A/C 6 Refrigeration IMES- CO WI G C - SALESMG C - SALES CONDUIT FROM MA ELECTRIC ROOM BY LL EC TROUGH DEMARK 1 PROVIDED PHONE CO. . BY TELEPHONE EQUIPMENT BOARD PROVIDED BY THOMAS ELECTRONICS. INSTALLED BY SPENCERS LG.. '•a SIDE MEW FLOOR 0 Li H- U CD z z z 0 0 F- 3 i CK cc < IJJ a. YZ co 3 CC U. NJ co 3 CCCZC C D W W O) !p cn J 3C he N CC < < M he m a r 011120 SHEET ED.2 ELECTRICAL SCHEDULE; THREE LIMITED PARKWAY COLUMBUS, OHIO 43230 614-415-7000 la DRAW. 01112004.0*g DATE: MAY 17, 2C01 A. NOTE B. GENERAL REQUIREMENTS 1. C. TENPORMY LIGHT AID POWER D. CODES E. LICENSES. PERMITS. INSPECTIONS & FEES G. GUARANTEE H. RECOWD DRAWN. DIVISION 16 - ELECTRICAL SECTION 16000 BASIC ELECTRICAL REQUIREIF.NTS 1. TFE ABBREVIATION L.S.P. WHEREVER IT APPEARS IN THESE ELECTRICAL DRAWINGS, SHALL REFER TO LIMITED SIRE PLANNING, INC. ANY REFERENCE TO TENANT'S. NT BATH AND BOOT WORKS PROJECT MANAGER OR FURNISHED BY ANY OF THE ABOVE REFERS TO L.S.P. 2. DRAWINGS AND GENERAL PROVISIONS OFF CONTRACT, INCLUDING GENERAL MID SUP'LEIENTARY CONDITIONS MC ALL ODER SPECIFICATION SECTIONS, ,WPLY TO THIS MID THE ODER SECTIONS OF DIVISION 16. 3. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS ROOK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 4. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE CQPLETION MC INSPECTION OF HIS NOOK MD THE WORK OF HIS SUBCONTRACTORS NOOK TO COMPLY WITH THE L.S.P. SCHEDULE AND THE PROJECT FAPLETION DATE. 5. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DEMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY MI) QUALIFIED IN THE CONTRACTOR S BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF IDKNILEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AMO SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFOWMANCE OF WON(. 6. REFER TO RESPONSIBILITY SCHEDULE ON THE ELECTRICAL DRAWINGS FOR INFORMATION IN REGARDS TO RESPONSIBILITY OF CORK OR ITEMS WHICH MAY AFFECT BID. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES. TOOLS, TRANSPORTATION, INCIDENTALS MD DETAILS NECESSARY TO PROVIDE COMPLETE ELECTRICAL. SYSTEMS AS SHORN ON THE DRAWINGS. CALLED FOR IN THE SPECIFICATIONS. MID AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LAWLOR°. POWER COMPANY OR L.S.P. SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE RETALIATION WITH LADLED. POWER COMPANY AND L.S.P. PROJECT WEER AS REQUIRED. FURNISH AND INSTALL EQUIPMENT THAT IS RATED FOR AVAILABLE FAULT CURENT LEVELS. EERIE AND INSTALL 'CABLE LIMITERS' IF NECESSARY TO LIMIT FAULT CURRENT. FIELD VERIFY TIE EXACT TYPE. SIZE, LOCATION, REQIIRE)ENTS, ETC. OF EXISTING PIN R MC TELEPHONE FACILITIES PRIOR TO EMISSION OF BID. 2. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, MD EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF. SHALL BE PEW, UDERNRITERS LABORATORIES LISTED AND LABELED MD SIZED IN CONFORMITY WITH REQUIREMENTS OF TIE NATIONAL ELECTRICAL CODE. STATE MD LOCAL CODES, WHICHEVER IS MORE STRINGENT. 3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTTER PEDANT MATERIAL OR LABOR CALLED FOR IN OE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY IENTIOIED IN BOTH. ANY MATERIAL OR LABOR 161101 IS NEITHER EOM ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS. BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WOK OR WHICH IS USUALLY INCLUDED IN MONK OF SIMILAR CHARACTER, SHALL BE PROVIDED AS PART OF CONTRACT. 4. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REWIREIENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS NOTED (THERWISE. 5. ALL ELECTRICAL ICS( SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING MD REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 6. THIS CONTRACTOR SHALL CO ALL CUTTING. CHASING, OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY L.S.P. PROJECT MANASR AN TIE LANDLORD. PATCHING IS TO MATCH SiREL/DING SURFACES. 7. THE ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL ERECTIONS AS REQUIRED FOR A COMPLETE MID OPERATING SYSTEM. 1. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL TDPORARY WIRING MD RELATED GROUND FAULT INTERRUPTION PROTECTION FOR LIGHT MC POWER FOR ALL CONTRACTORS AND IS RESPONSIBLE FOR ITS REMOVAL. 2. THE GENERAL CONTRACTOR SHALL PAY FOR ALL ELECTRICITY PRIOR TO STORE MERCHANDISING AND INCLUDE COST IN BID. 1. ALL WORK SHALL BE PERFORMED IN A NEAT AND PROFESSIONAL MANNER AND CONFORM TO THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE, LANDLORD'S CRITERIA, THE STATE'S. COUNTY'S, CITY'S AND LOCAL CODES MID ORDINANCES. SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES, AND ALL OTHER APPLICABLE CODES AND REQIIRENENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES. ORDINANCES. MI) REGULATIONS. THIS CONTRACWR SHALL INCLUDE ANY CHANCES REQUIRED BY CODES IN DE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY LUST HE QUALIFIED AS A SEPARATE LIPS ITEM IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY L.S.P. TO THE CONTRACTOR. THIS CONTRACTOR SHALL OBTAIN MD PAY FOR ALL LICENSES, PERMITS, INSPECTIONS. MD FEES REQUIRED CR RELATED TO THIS NORM(. 2. FURNISH TO L.S.P. PROJECT MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION O PROJECT. F. TRADE NNES, MAMFACTURERS AND SHOP DRAWINGS 1. WERE TRADE NAMES MID MADFACTOERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS. THE EXACT EQUIPMENT SHALL BE USED AS A MINIMS FOR THE BASE BID. MANUFACTURERS CONSIDERED AS MI EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING, TROUGH SHE DRAWING SUBMITTAL PROCESS, BY L.S.P.'S PROJECT MANAGER/ENGINEERING MANAGER PRIOR TO ACCEPTANCE. THff USE OF ANY UNAIDDRIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL MD REPLACEMENT AT TEE CONTRACTOR'S EIPEMSE 2. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO L.S.P. PROJECT MANAGER FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENDUE IN PROJECT TO ALLOW FOUR (4) WOKING DAYS FOR L.S.P. PROJECT MANAGER'S REVIEW WITHOUT CAUSING DELAYS CR CONFLICTS TO THE JOB'S PROCESS. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL CONTRACTOR MD SUB - CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIWED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE MERE EXCEPTIONS HAVE BE TAKEN. 1. THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS MD WORK PROVIDED UNDER THIS CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT CONTRACTOR'S OMAN EXPENSE, ANY DEFECTIVE WORK, MATERIAL. CR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTMGE (IN WRITING) OF THE INSTALLATION BY L.S.P.'S PROJECT MANAGER/ENGINEERING MANAGER. EXTENDED WARRANTIES ARE SPECIFIED WITH INDIVIDUAL EQUIPMENT. 2. L.S.P., INC. SHALL PROVIDE A COMPLETE 12 -METH WARRANTY FOR ALL PARTS ON EQUIPMENT PROVIDED BY L.S.P., INC. MD L.S.P. S VENDORS. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE YOKING SYSTEM. AND AS SUCH. ND ADDITIONAL MNHES SHOULD BE INCLUDED IN THE BID. 1. THIS CONTRACTOR SHALL MAINTAIN ONE COY OF DRAWINGS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS. SUCH AS: A. LOCATION OF JUNCTION BOXES AND RECEPTACLES. B. REVISIONS, ADDENDUS, MD CHANGE ORDERS. C. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, MD CONTRACTOR'S COORDINATION WITH ODER TRADES. 2. AT COMPLETION OF PROJECT MD BEFORE FINAL APPROVAL. THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE TEEREON. ONE COPY OF DRAWINGS STAMPED OR NOT REEVE' SHALL BE PLACED IN DRAWING TIME LOCATED NEXT TO THE ELECTRICAL PANELS (SEE ARCHITECTURAL DRAWINGS FOR LOCATION). DISCREPANCIES IN DOCUENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIACRMWATICAL MO INDICATE THE GENERAL LOCATION MD INTENT OF THE ELECTRICAL SYSTEMS. WERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE TIE GENERAL CONTRACTOR IN WRITING PRIOR TO SUBMITTAL O BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE L.S.P.'S PROJECT MANAGER IN WRITING OF ANY VARIATIONS TO CONTRACT DOCUENTS PRIOR TO SUBMISSION OF THE BID. OTHERWISE. L.S.P. PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. 2. DE LOCATION OF OUTLETS AND EQUIPENT SHEN ON THE DRAWINGS ARE APPROXIMATE AND SCHEMATIC IN NATURE. L.S.P. SHALL HAVE TIE RIGHT TO RELOCATE ANY CURETS OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. J. PHASING REQUIREMENTS 1. K. DEDLITION 1. 2. THIS CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING CONDUIT, FIRE ALARM SYSTEM, SWITCH (EAR. PITCH POCKETS MD EQUIPMENT ETC. UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR EST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, CODUIT AND SWITCH GEAR PRIOR TO REMOVAL. PITCH POCKETS SHALL BE REIAVED AND THE ROOF PATOED. AS REQUIRED BY ON THE ME LANDLORD. ALL THE NEW WORK EST BE REEEVED AND O RO /RALL/FLOOR LIKE YEW TO CONDITION. EXISTING ABBBCQIIED CONDUIT OR EQUIPMENT IN THE FLOOR. EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE. ARE TO BE CUT OFF MI) SEALED BELOW CR WITHIN FLOOR OR WALL LEVEL WEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LMCLORD OR CODES. ABMI)ONED CODUIT MIST BE REPINED TO POINT OF ORIGIN. CONFIRM EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN PROPOSAL. L. SLEEVES M. HANGERS END OF SECTION 16000 A. SCOPE O WORK B. CONDUIT C. D. FOR MY PHASED STORE COMSTRUCTIOM, THIS CONTRACTOR IS TO INCLIAE IN THE BID ALL NECESSARY ELECTRICAL SERVICE CHANGES REQUIRED TO KEEP THE OPERATING RUSE OF THE STORE'S ELECTRIC SERVICE IN OPERATION. CONTRACTOR MIST SCHEDULE WITH L.S.P.'S PROJECT MANAGER AND LANDLORD (IN WRITING) ONE WEEK PRIOR TO ANY MM DOW OF THE POE, CASH REGISTERS, ELECTRICAL. TELEPHONE OR FIRE ALARM SYSTEMS. ADVISE GENERAL CONTRACTOR AT TIE OF BID IF ANY CONFLICTS EXIST. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR TIE CODRDINATIDN OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COODINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT TO BE LEFT INTACT AND ADVISE L.S.P.'S PROJECT MANAGER AT TIME OF BID. 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL. EXTEND THROUGH ITS RESPECTIVE FLOOR. WALL CR PARTITION MO SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2' ABOVE TIE FLOOR. 2.. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS MD /OR FLOORS MALL BE FIRE SEALED WITH CALCIUM SILICATE. SILICONE'RTV' FOAM, '3M FIRE RATED SEALANTS OR EQUAL, 50 AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS. FLOORS AND PARTITIONS SHALL BE STANDARD IVEIGT STEEL PIPE FINISHED WITH SICOTN EDGES. FOR OTHER THAN WENT PARTITIONS, THROUGH SUSPENDED CEILINGS, CR FOR CONCEALED VERTICAL CONDUIT, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIER. 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL 9CH AS ANGLE IRON. WIRE, UNISTRUT, GIMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL. CONCRETE. OR MASONRY. BUT NOT TO OTTER CODUIT OR PIPING. HANDERS UPPER ATTAENENT EST BE SUPPORTED FROM THE TOP OF TIE BAR JOIST. HANGING FROM METAL DECK IS NOT PERMITTED. WHERE INTERFERENCES OCCR, IN ORDER TO SUPPORT CODUIT, THE CONTRACTOR EST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED MERE THEY CO NOT INTERFERE WITH ACCESS TO FIRE DIAPERS. VALVES, JUNCTION BOXES, ACCESS DOORS, OTHER EQUIPENT SERVICE REQUIREMENTS AND/OR OTHER TRADES. RANGER TYPES AND INSTALLATION METHODS NE SUBJECT TO LANDLORD CRITERIA. N. FINAL ELECTRICAL INSPECTIONS 1. ASIDE FROM NOMAL INTERIM INSPECTIONS OF WORK IN PLACE, L.S.P. SHALL HAVE AN INDEPENDENT ELECTRICAL CONTRACTOR INSPECT THE FINISHED ELECTRICAL INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PANS. SPECIFICATIONS NO CODES. THE ORIGINAL ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE. TO BRING ALL (TENS REPORTED UP TO PLR. AND SPECIFICATION'REQUIREIENTS. DIVISION 18 -. ELECTRICAL SECTION 16050 BASIC ELECTRICAL MATERIALS AND MEMOS I. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPENT, SERVICES, TOOLS. TREE:I:RATION, AND FACILITIES NECESSARY FUN, REASONABLY BELIED AND INCIDENTAL TO, THE FURNISHIMO, INSTALLATION, COMPLETION AND TESTING OF ALL THE WON FOR TIE ELECTRICAL SYSTEMS AS SEWN ON THE DRAWINGS, GALLED FOR IN THE SPECIFICATIONS. AND AS REQUIRED BY JOH CONDITIONS. TO INCLUDE. BUT NOT BE LIMITED T0 THE FOLLOWING: A. A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM INCLUDING THE INSTALLATION OF L.S.P. PROVIDED PANELBOMDS, SAFETY AND DISCONNECT SNITCHES, MOTOR STARTERS, LIGHTING CONTACTORS, LIGHTING. AND TRANSFORMS. . IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO INCLUDE IN THIS BID FOR PROVIDING SERVICE EQUIPMENT NECESSARY. FOR TIE-IN TO LANDLORD'S DISTRIBUTION DEMENT OR TO OBTAIN SERVICE FROM LOCAL UTILITY COMP. REFER TO. ELECTRICAL RESPONSIBILITY SOEEULE AND ELECTRICAL POWER RISER DIAGRAM FOR ADDITIONAL IRFOANATIO1. B. CONTRACTOR EST ALSO INGLUDE IN BID AU. NECESSARY MATERIALS REQUIRED TO COMPLETE THE SYSTEM INCLUDING, BUT NOT LIMITED TO, FEEDERS, BRANCH CIRCUITS, JUNCTION COXES. OUTLET BOXES, WIRING DEVICES, COVERPLATES, EMITS, ETC. C. METERING MD CURRENT TRAEFORLERS AS REQUIRED BY DRAWINGS, L.S.P., UTILITY COMPANY. MD /OR LANDLORD. D. THE WIRING OF MECHANICAL EQUIPMENT AS OUTLINED UN THE BID SET DRAWINGS AND IN THE SPECIFICATIONS. ME SHALL INCLUDE WIRING OF ALL STARTERS, DISCONECTS. MD POWER WIRING OF NECHNIICAL EQUIPMENT EXCEPT AS SPECIFICALLY NOTED OTHERWISE. ALL LOIN VOLTAGE (24 VOLT) TEMPERATURE CONTROL WIRING SHALL BE TIE RESPONSIBILITY OF THE CARRIER CONTROLS TECHNICIAN UNLESS NOTED SPECIFICALLY on DRAWING. E. INSTALLATION OF LIGHT FIXTUES AND LAPS AS SHOWN ON THE DRAWINGS INCLUDING ALL DEVICES. EQUIPENT, ETC. REQUIRED FOR MOUNTING. F. A COMPLETE CODUIT SYSTEM FOR TELFPIIME/DATA INCLUDING TERMINAL BOARD. BRANCH CONDUITS. OUTLET BOXES. PULL WIRES. GROUND COOICTORS, COVER PLATES. ETC. OR AS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. G. A COMPLETE EMERGENCY AND EXIT LIGHTING SYSTEM AS SHOW ON TIRE DRAWINGS. H. TEMPORARY SERVICE M INDICATED IN THE SPECIFICATIONS. INCLUDING IT'S REMOVAL. I. FINAL CONNECTIONS TO ALL SIGNS, CORNICE LILTING, CASE LIGHTING, ETC. AS SHORN ON DRAWINGS. I J. INSTALLATION AND WIRING OF SPEAKERS, AMPLIFIES. YM1 OTT AID FRAIL manors FOR SONO SYSTEM AS SHOWN ON DRAWINGS. K. SMOKE/FIRE ALAN WIRING. DEVICES AND CONDUIT. AS WE CR DESCRIBED ON DRAWINGS OR AS NECESSARY. TO MEET LADLORD, STATE, LOCAL, INSURANCE AND FIRE DEPARTMENT REQUIREIEENTS. L. INSTALLATION OF CONDUITS STUBBED TO ABOVE CEILING FOR'HVAC AD /OW LIGHTING CONTROL PANEL.. ALSO. ANY ADDITIONAL CONDUIT FOR MAC CONTROL EQUIPMENT WERE PLENA RATED CABLES ARE NOT PERM-TED. COORDINATE WITH CARRIER CONTROLS TENNICIAR. 2. CORK NOT INCLUDED THE FOLLOWING ITEMS OF ELECTRICAL CONSTRUCTION ME NOT INCLUDED IN THIS CONTRACT: A. 24 VOLT TEMPERATURE CONTROL WIRING UNLESS NOTED OTHERWISE. B. TELEPHONE INSTRINENTS MD WIRING UNLESS NOTED OTHERWISE. C. DATA LINES WIRING MESS NOTED . OTHERWISE. 3. BEFORE STARTING W M, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, FIRE PROTECTION, MECHANICAL, AND PLUMBING PUNS, SHE CRAWTXS AND SPECIFICATIONS TO SEQUENCE. COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE ELECTRICAL SYSTEM, MATERIALS, MI EQUIPMENT WITH OTHER CCNTRACTOS TO AVOID INTERFERENCES NO CONFRONTATIONS. 1. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUITS SERVING ALL EQUIPMENT. INCLUDING BUT NOT LIMITED TO, LIGHTING, RECEPTACLES, HEATING. AIR CONDITIONING, PEEING EQUIPMENT. TELEPHONE. DATA, SPENCERS. MO ELECTRICAL EQUIPMENT. 2. ALL CONDUITS SHALL BE GALVANIZED INC OR EMT UNLESS OTHERWISE SPECIFIED IN SPECIFICATIONS OR OM DRAWINGS. ALL CONDUIT IS TO BE UL LABELED. DR CORRECTORS SHALL BE STEEL COMPRESSION OR SET SCREW TYPE. CODUIT UDER SLAB 01 GRADE SHALL BE RIGID STEEL. OR SCHEDULE. 40 PVC. WITH. RIGID STEEL. ELLS WERE. PERMITTED . BY LANDLORD OR CODE. 3. MINIMUM SIZE O CONDUIT SHALL BE I/2' FOR INDIVIDUAL LIGHTING FIXTURE CONRECTIO.S CR TO INDIVIDUAL LIGHT SNITCHES (IF ACCEPTABLE BY THE LANDLORD AND LOCAL CODE OFFICIALS) MD 3/4' FOR ALL ODER LOCATIONS. IF /VAC CONTROL WIRING IS REQUIRED TO BE RUN IN CONDUIT, IT SHALL BE A MINIMA OF 3/4'. UNLESS NOTED OTHERWISE ON DRAWINGS. •'.. IN/UNDER FLOOR CODUIT SHALL BE OF MINIMA 3/4' SIZE. 4. SUPPORT ALL CODUIT, INCLUDING SEISMIC AND SWAY BRACING. IN ACCORDANCE WITH THE NEC AND LOCAL CODES. 5. GENERALLY, ALL CODUIT SHALL BE CONCEALED EXCEPT FOR UNFINISHED AREAS, SUCH AS EMINENT RODS. EIP(SED CODUIT SHALL BE ALLOWED ONLY AS NOTED OM.PLAN ABC AS APPROVED. BY L.S.P.'S PROJECT MANAGER. PAINTING O CONDUITS, NOTED ON DRAWINGS OR'SPECIFICATIOM WILL BE BY GENERAL. CONTRACTOR. 6. FLEXIBLE METAL CODUIT OR MO TYPE CABLE A. FLEXIBLE CONDUIT CR MO TYPE CABLE SHALL BE USED FOR THE FOLLOWING APPLICATIONS ONLY: 1. FINAL CORRECTIONS TO MOTORS. 2. FINAL CONNECTIONS INTO AND CUT OF THE TRANSFCNER. 3. FINAL CONNECTIONS TO VIBRATING EQUIPMENT. 4. INTER-COHECTIONS BETWEEN ALL LIGHT FIXTURES. (NOT TO INCLUDE HOIERUN FROM FIXTURE OR DEVICE TO PANELBOAND, WHICH EST BE RIGID). 5. FINAL CONNECTIONS WERE RIGID CODUIT IN NOT PRACTICAL. 6. IN WALLS (FOR LIGHT SWITCHES AND 120 VOLT POWER RECEPTACLES AND HVAC COTROL EQUIPMENT). B. FLEXIBLE METAL CONDUIT OR MC TYPE CABLE MOST BE THE SAE SIZE AS THE IMO OR DR CODUIT TO WHICH IT IS CONNECTED. BOTH THE FLEXIBLE METAL CODUIT AND IT'S FITTINGS ARE TO BE LISTED FOR GROANING. A GREEN GROUNDING COMER SHALL BE INSTALLED. ALL CORRECTORS ARE TO BE OF A NEW APPROVED TYPE. THE USE OF ROEX, BO, ETC. IS NOT PERMED. CONNECTION TO OUTDOOR EQUIPMENT MST BE WEATHERPROOF. I.E. ' LIQUIDTIGT CR 7. PROVIDE PULL -HIRE IN ALL EMPTY CONDUITS EXCEPT AS NOTED ODEBWISE ON DRBBINCS. 8. FICHE RUNS AID AMAIN CONDUIT RUE ARE TO E HELD TIGHT TO STRICTURE ABOVE OR AS REQUIRED TO ALLOW PROPER SERVICE ACCESS MO OTHER TRADES WM. CODUIT EST BE TRAPEZEDD TO ALLOW 3 FEET MINIMA CLEARANCE ABOVE CEILING. B. ALL CONDUITS WE BE SIZED PER NEC AND LOCAL. CODES. C. OUTLET BOXES 1. ALL OUTLET BOXES SHALL BE GALVANIZED PRESSED STEEL OF THE STAIDMD KNOO(ODT TYPE. NO ROOD OUTLET BOXES SHALL BE PERMITTED, EXCEPT AS SPECIFICALLY NOTED OR DRAWINGS. CONCEALED BOXES SHALL NOT BE LESS THAN 4 SQUARE AID 1 I/2 DEEP, HIM PLASTER RINGS. 2. ALL KNOCKOUT BOXES, UPON WHICH LIGHTING FIXTURES ARE TO BE INSTALLED, SHALL BE EQUIPPED WITH 3/8' FIXTURE STUDS. 3. EXTERIOR BOXES SHALL BE CAST RUST - RESISTING METAL WITH GARETED MEPS. 4. INSTALL BOXES RIGIDLY FROM BUILDING STRUCTURE AND SUPPORT IIDEPEIDDITLY OF TIE CODUIT SYSTEM. ALSO PROVIDE SUITABLE BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES CF FLOORS, CEILINGS, WALLS ETC. AU. CUTLET BOXES TO BE PROVIDED WITH CADDY QUICK -IONT BOX SUPPORT TO MINIMIZE TIE DEFLECTION THAT OCCURS WEN PLUGGING/EVENING INTO THESE DEVICES. 5. UNLESS OTHERWISE NOTED ON DRAWINGS OR OTHERWISE REQUIRED BY THE NATIONAL ELECTRICAL CODE, HANDICAP ORES R LOCAL CODES, OUTLET HEIGHTS SHALL BE AS FOLLOWS: A. SWITCH HEIGHT 48' FROM FINISHED FLOOR TO CENTERLINE OF OUTLET. B. CONVENIENCE CURETS: SALES: HORIZONTALLY MOUNTED IN BASEBOARD BENEATH CABINETS, AS SHOW ON OMAWNS, OR AS REQUIRED BY LOCH. CODES. NON SALES: 18' FROM FINISHED FLOOR TO CENTERLINE OF OUTLET. C. TELEPHONE OUTLETS SHALL BE LOCATED AS NOTED ON DRAWINGS. D. JINITIOR MD PULL BOXES ELECTRICAL SPECIFICATIONS 1. THE PLANS INDICATE ONLY SOMATIC ROUTINGS FOR CODUIT RES. THIS CONTRACTOR SHALL FURNISH AND INSTALL ADDITIONAL BOXES WERE REQUIRED BY FIELD CONDITIONS OR BY CCOE. 2. BOXES AND COVERS SHALL BE GALVANIZED STEEL OF COME GAME SIZE. 3. INSTALL BOXES RIGIDLY SUPPORTED ERN TIE BUILDING STRUCTURE ARC SUPPORTED INDEPENDENT OF TIE CODUIT SYSTEM. 4. ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION EMS IN IBACCQSSS.iE LOCATIONS. THE USE OF JUNCTION BOXES MOVE DRYWALL CEILINGS SOLD BE LIMITED TO LOCATIONS EAR ACCESS FRAMES USED FOR DIFFUSERS ND RETURN AIR GRILLES OR ACCESS PANES AS LOCATED ON PUNS. 5. JUNCTION AND PULL BOXES REST BE LABELED WITH CIRQUIT NUBER IDENTIFICATION AND SYSTEM TYPE OM COVER. E. WIRING 1. CONDUCTORS FE FEEDERS AND BRANCH CIRCUITS SHELL BE COPPER AND TEE MG SIZE MD TYPE AS SERI MI DRAWINGS. MINIMM.WIRE SIZE 112. THE COMUCTOS SHALL BE 800 VOLT INSULATION,'. TYPE TIN. MN AIR' TIN. 2. MINIMA WIRE SIZE - 20 AMP BRANCH CIRCUIT SHALL BE AWE LISTED SIZE PER DISTANCE SHDAN BELOW. DISTANCE SHALL BE IEAOTRED FROM TIE PAELBOND CIRCOIT BREAKER TO THE FURTHEST CUTLET. A. 112 LESS THAN 100 FEET B. 110 BETWEEN 100 -150 FEET C. #8 BETWEEN 150 - 250 FEET D. NW OVER 250 FEET 3. ON ALL 20 NP BRANCH CIRCUITS, CONDUCTORS LARGER THAN 110 AMG SHALL BE REDUCED TO 110 AMC WITHIN 10 FEET OF PANEL BOARD ND DEVICE IN JUNCTION BOXES CI RATED TERMINAL STRIPS. 4. CONDUCTORS. MAY BE STRANDED FOR SIZES 1IO AND AND LARGER. CONDUCTORS SIZE 112 SHALL BE SOLID (RN STRANDED). 5. ALUMNA CONDIICTCS ARE NOT PERMITTED. EXCEPT AT SERVICE ENTRAWE. WERE REQUIRED BY LAIWLOG. CONDUCTOR CONECTION MIST BE PER'MANFACNER'S REQUIRDENTS. CONTRACTOR MST ADVISE GENERAL CONTRACTOR AND L.S.P.'S PROJECT MANAGER WEN USED. B. ALL WIRING SHALL E IN COMET. MESS SPECIFICALLY NOTED OTHERIFISE (IE. LON VOLTAGE PLEAS RATED WIRE). 7. RE USE O MIRED NEUTRALS IS REQUIRED FOR LIGHTING CIRCUITS ND SHALL BE INSTALLED IN ACCORDANCE WITH TIE NATIONAL ELECTRICAL CODE AND LOCAL CODES. ALL OTHER EQUIPMENT REQUIRING A NEUTRAL CONDUCTOR SHALL HAVE A DEDICATED FULL SIZE NEUTRAL. 8. TIE USE O -ROE%. BX, ETC. IS WI PERMITTED. 8. WIRE CONECTOS SHALL BE EQUAL TO 'SCOTCH LOW(' FOR 18 AM WIRE ND WALLER AND EQUAL TO T IN 8 'LOCKTIGHT FOR N MD AND LARGER. 10. ALL WIRING TO BE COLOR -DEED AS FOLLOWS: F. WIRING DEVICES 170 /GDP VD T SYSTEM 21U429.22.1.9=1 NEUTRAL - WHITE PHASE A OR LI - BLACK PHASE B OR L2 - RED PHASE C OR L3 - BLUE CROWD GREEN NEUTRAL - GRAY RUSE A OR LI - BROM RASE U CR 1.2 CRINGE PHASE C CR U - YELLI N GREEN WITH YELLOW TRACER I. THIS CONTRACTOR SHALL FURNISH AND INSTALL. SYITO/ES AND RECEPTACLES, miss NOTED. OTHEWISE, AS NECESSARY FOR A COMPLETE INSTALLATION. COLOR OF DEVISES AND PLATES SWILL BE SELECTED BY L.S.P. TIE DEVICES SHALL BE OF THE TYPES AND RATINGS LISTED, OR EQUALS BY AIRO.ABRRT,' GENERA.'.. ELECTRIC OR PASS a SEWER. WEATHERPROOF WI RECEPTACLES SRRLL BE INSTALLED WERE NON OR DRAWINGS OR AS REQUIRED BY CODE. SINGLE POLE SWITCHES: 20MP -' 120 -27Th IWWBELL 06 -1221 THREE. WAY SWITCHES: 20NP - 120 -277V: IWBELL .1. -1223 DUPLEX RECEPTACLES: ENV - 125V: HUBBELL 5382 ISOLATED GEED RECEPTACLES: 20AP -. 125V: HBBELL 1E362 GROAT FAULT CIRCUIT INTERRUPTING RECEPTACLES: 20AP - 125V: HUBBELL 05352 ALL DEVICE O)VERPLATES SHILL BE PASS AND SEWER SERIES 'RP' OR EQUAL BY EAGLE ELECTRIC MFG. CO.. G. HEATING. VENTILATING B AIR CONDITIONING, PLUMBING, AND FIRE PROTECTION WIRING 1. ELECTRICAL CONTRACTOR SILL REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL ELECTRICAL WON( TO BE INU7.UDED IN HIS BID. 2. ELECTRICAL COINTRACTOR SHALL CO ALL POWER WIRING, LINE VOLTAGE WIRING, NO LINE VOLTAGE CONTROL WIRING INDICATED UNDER TIE HEATING. VENTILATION AND AIR COCITIONIE. PLIRCINO AND FIRE PROTECTION SPECIFICATIONS ARC DRAWINGS. THIS CONTRACTOR SHALL ALSO DD ALL INTERCONNECTING LINE VOLTAGE WIRING BETWEEN RELAYS AND SWITCHES AS REQUIRED. 3. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL AS A MINIMA, CONDUITS STABBED FRCN HVAC MD /OR LIGHTING CONTROLS LOCATED 01 THE TELEPHONE BOARD TO 12' ABOVE CEILING WITH PLASTIC CODUIT BUSHING TO PREVENT WIRE CHAFFING. COORDINATE WITH CARRIER CONTROLS TECHNICIAN. 4. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FURNISHING. AND INSTALLING CONDUIT FEW HNC CONTROL WIRING MERE REQUIRED BY CODE TO BE IN CONDUIT. REFER TO PLANS FOR REQUIREMENTS NO SIZE. 5. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS OF MAY THERMOSTATS, SENSORS, CR ADDITIONAL TEWERATUE CONTROL COMPONENTS VIER PLENA RATED CABLE IS NOT PERMITTED AND ADDITIONAL CODUIT IS REQUIRED. H. SAFETY AND DISCOMECT SNITCES SAFETY AND DISCOIRECT SWITCHES SHALL BE HEAVY DUTY TYPE, QUICK -MAKE, NICK-BREAK FUSED. OR NON- FUSIBLE WITH RATING AND SIZES AS NOTED ON PLANS AND REQUIRED BY CODES. 2. SWITCHES SHALL BE WEATHERPROOF IN OUTDOOR LOCATIONS OR AS REQUIRED BY LOCAL CODES. DISCODECT SNITCHES THAT ARE INSTALLED AT }EATING, VENTILATING AND AIR CONDITIONING (NE) EQUIPMENT SHALL BE FUSED IF NOT PROTECTED WITH A 'HACR' BREAKER IN ACCORD/NE WITH TEE EQUIPMENT'S NAEPLATE AND IMMFACTINER'S REQUIREMENTS PER THE NATIONAL ELECTRICAL CODE, STATE AND LOCAL CODES. 3. AT SERVICE ENTRANCE, DISCONECT SHALL BEAR TIE MNEFACTUER'S LABEL INDICATING THE EQUIPMENT IS LL RATED FOR APPLICATION IN ACCODNGE WITH ALL COES. 4. CUTLER-HAVER MANUAL MOTOR STARTERS, LESS OVERLOAD PROTECTION HEATERS, ARE TO BE USED AS A DISCONECTINO MEANS ONLY WERE INDICATED ON DRAWINGS FOR FRACTIONAL HORSEPOWER ALTOS ABOVE 1 1/2 If AT 120 VOLTS AND 2 HP AT 240 VETS THAT CO. NOT REQUIRE AUXILIARY CONTROL. MOTORS THAT ARE BELOW TIE 1 1/2 HP AT 120 VOLTS, 2 EP AT 240 VOLTS. WATER HEATER ARC ROLLING GRILLE ARE TO BE PROVIDED WITH REBELL IBL -1221 OR 1222 ' SWITCH. 5. MANUFACTURE SHALL BE CU LER-IIMER. I. NDTOR STARTERS 1. MAGNETIC NOTE STARTERS SHALL BE PROVIDED WITH RESET TYPE OVERLOADS THAT CLOSELY IMTCH IATDR NAMEPLATE RATING AND SHALL BE ELECTRICALLY HELD (MINIMA SIZE 11 IN A PEW 1 ENC.OSEE) MD BE USED FOR ALL SINGLE PHASE MC THEE PHASE MOTORS RATED ABOVE 1/2 If THAT REQUIRE AUXILIARY CONTROL. PROVIDE CONTROL DEVICES (AUXILIARY CONTACTS, TRANSFONERS, H-O-A, ETC.) IN STARTERS AS REWIRED FOR INTERLOCKS. COORDINATE ALL CONRNX. DEVICES WITH IECHMICAL CONTRACTOR. COMBINATION STARTER/DISCONNECT SWITCHES SHALL CONTAIN FUSIBLE SWITCHES AN) ONLY USED WHERE INDICATED ON DRAWINGS. 2. MANUFACTURER SHALL BE DITLER- HAVER. J. OROIRDING 1. FIXN191 AND INSTALL . COMPLETE WIRED GROUNDING CONDUCTOR SYSTEM, f12 AWE MINIMUM, SIZED AND INSTALLED IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE, STATE MD LOCAL CODES, TIE LANDLORD'S TENANT CRITERIA AND AS NOTED IN THE SPECIFICATIONS AND AS INDICATED ON THE DRAWINGS. 2. ALL CONDUIT. INCLUDING FLEXIBLE CONDUIT, SHALL BE GROUNDED WITH A GREEN GROUNDING CONDUCTOR. 3. GROUNDING CONNECTIONS MADE TO TIE WATER PIPING SYSTEM SHALL BE COORDINATED WITH TIE PLUMBING CONTRACTOR AND A BODING JUMPERS INSTALLED ADORN) WATER METER PER CODES AD AS INDICATED ON DRAWINGS. 4. ALL DEVICES SHALL BE BODED TO THE CODUIT SYSTEM. USE A BODING RIPER BETWEEN THE CUTLET BOX AND TIE DEVICE GROUNDING TERMINAL. METAL -TO -METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOB IS NOT ACCEPTABLE AS A BCD FOR EITHER SURFACE WONTED BOXES OR FLUSH TYPE BOXES. ALL JUNCTION BOXES. TOOLED BOXES. AND RILL BOXES SHALL BE BONDED TO TIE CONDUIT SYSTEM. 5. RUN A SEPARATE ISOLATED GROUNDING CONDUCTOR, 112 AWE MINIMA, IN EACH CONDUIT FEEDING THE CASH WRAP. TIE SENSOWAATIC, HVAC CONTROL PANEL, AND OTHER COMPUTERIZED EQUIPMENT AS SHOW! ON DRAWINGS. 8. PEW PANEL FEEDERS. BOW THE GROUNDING CONDUCTOR TO TIE CODUIT, WERE ENTERING AND LEAVING THE CONDUIT. Tiff CREWING CONDUCTOR SHALL BE COPPER TITH'GREEN IDENTIFICATION AND SIZED PER N.E.C. 7. ALL ENCLOSURES AND NON- OTWENT CARRYING METAL PARTS ME TO BE GROIRDED. CONDUIT SYSTEM IS TO BE ELECTRICALLY CNTI1 S. ALL LOCIOMS MST CUT THROUGH ENAMELED OR PAINTED SURFADES ON ENCLOSURES. WERE ENCLOSURES MW NCR-CURRENT CARVING METAL PARTS ARE ISOLATED FROM TIE CODUIT SYSTEM, USE BODING JUPERS WITH APPROVED CHIRPS. ALL GROUND CLAWS SHALL BE PEN-LEON OR EQUAL, SIMILAR TO ,',PI. TYPE. K. OM TYPE TRMSFOWERS 1. TRANSFORMERS ARE PE -WIRED AND ERE- INSTALLED IN IFS UNIT. TRNSFOBERS SHALL BE LOOTED, SET, RENTED AND CODECTED IN 9UOI A MAKER AS TO KEEP NOISE LEVELS WITHIN THE SURROUNDING ANCIENT NOISE LEVELS AND MAINTAIN ALL CODE REQUIRED OLEAN/ICES. 2. TRANSFORER SHALL BE QUIET TYPE CONSTRUCTION. AID HAVE SIX (8) 2 1/2X TAPS, TWO (2) TAPS ABOVE ARC FOUR (4) TAPS BELOW NORMAL PRIMARY RATING. 3. MANUFACTUER SHALL BE CUREMWNER. L. PMEEDARIS 1. ALL PNELBOAIWS SHALL BE FACTORY ASSEMBLED OF TIE BOLTED CIRCUIT BREAKER TYPE WITH SOLID COPPER BUSSING, FULL SIZED COPPER NEUTRAL, 10OCGROXW 9BSING, OVERALL HINGED/LOODBLE DOOR. PRE - INSTALLED ARC PRE-WIRED IN IFS UNIT. ALL CIRCUIT BREAKERS SHALL BE OF THE 13010K -1AIC MO WICK -WEAK DESIGN, TIEAMAWIMNETIC TYPE, TRIP FREE AND TRIP- INDICATING. 2. CONTRACTOR SHALL FURNISH AND INSTALL A TYPEWRITTEN. DIRECTORY CARD O THE CIRCUITS AND PLACE IN PAEL DER. 3. ALL PAIELBOADS'PNRSE RPERAE SHALL BE BALANCED TO AITHIN 7 PERCENT MM. TO MIN. REARRANGE NE-LIGHTING BRAWN CIRCUITS AS REQUIRED AND NOTE CHANGES 01 RECORD DRAWINGS. LILTING PANEL CIRCUIT BREAKERS MST BE INSTALLED AND WIRED EXACTLY AS SHUN ON DRAWINGS. 4. PANELBCOWS SHALL HAVE A MINIMA SHORT CIRCUIT CURRENT RATING AND LUG CONNECTIONS AS FOLLOW: 120/208 VOLT PARELBOAJS: 65,000 A.I.C. 277 /480 VOLT PMELBONBS: 65,000 A.I.C. VERIFY ACTUAL A.I.C. SHORT CIRCUIT CURRENT REOJIRENENTS WITH THE LANDLORD OR UTILITY COPANY. AL LUG CONNECTIONS . TO BE 75'C RATED. 5. MANEACTIN ER SHALL BE CUTLER- R6WER. N. LIGHTING FIXTURES B LANDS 1. THIS CWTRACTQW SHALL INSTALL ALL LIGHTING FIXTURES AND LAPS AS SHOWN ON THE DRAWINGS. LIGHTING FIXTURES MW LAPS ARE SUPPLIED BY L.S.P., UNLESS NOTED OIERWISE. CONTRACTOR Is TD REPLACE ALL NON- YDR(ING LAPS PRIOR To MRCHNDISE DATE AND IS TO INCLUDE COST IN BID. 2. ALL RECESSED INCANDESCENT FIXTRES SHALL BE MOVIDED WITH APPLICABLE THEWMAL PROTECTION. 3. WERE FLUORESCENT FIXTURES ARE SPECIFIED, THEY SHALL BE PROVIDED WITH HIGH. POOR FACTOR RAPID START BALLASTS. U.L. LISTED. C.B.M. CERTIFIED. AND E.T.L. APPROVED WITH EFFICIENCY FACTORS IN ACCOORGE WITH THE ENERGY POLICY ACT OF 1692' AND ITS AEIWMENTS AS A MINIMA. 4. THIS CONDUCTOR SHALL FURNISH ADDITIONAL AUXILIARY SUPPORT STEEL HANGER WIRES ADEQUATELY SIZED TO SUPPORT THE WEIGHT CF TIE FIXTURE FASTENED TO TIE BUILDING STRUCTTM' (MINIMS TWO PER FIXTURE) FOR ALL FIXTURES IN LAY -IN CEILINGS AND OTHER FIXTURES AS. REWIRED BY TIE LANDLORD AXIS LOCAL CBE OFFICIALS. 5. FINNISH MD INSTALL ' APPLICABLE FIRE RATED DRYWALL BOXES OVER RECESSED FIXTURES IN FIRE RATED CEILINGS AS REQUIRED BY CODES. FIELD COODINATE AS REQUIRED TO AVOID CONFLICTS. N. LIGHTING CONTROLS 1. WERE LIGHTING CONTROLS ARE INDICATED ON DRAWINGS, A LIGHTING CONTROLLER WILL BE FURNISHED BY L.S.P. PRE- INSTALLED IN IFS UNIT. TIE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE TO PALISH AND INSTALL ALL CONDUITS AND WIRE TO RELAYS IN IFS UNIT.. LIGHTING TO BE CIRCUITED EXACTLY AS DIAGRAMED ON DE LIGHTING PLAN DRAWINGS. NO VARIATIONS TO 71E CIRCUITING ARE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL FROM L.S.P.'S ENGITEERINO MANAGER. 0. TELEPHONE DATA RD COMPUTER WIRING 1. FURNISH ND INSTALL A SYSTEM OF CONDUIT RACEWAYS, OUTLET BOXES, PULL WIRES, AND TERMINAL BARDS AS SHOWN ON THE DRAWINGS UNLESS OTHERWISE NOTED ON PLANS. TELEPHONE SWITCHING APPARATUS, INDUCTORS, INSTRUMENTS, NISCELLANEOUS EQUIPMENT AND APPURTENANCES ARE NOT PART O THIS CONTRACT AND WILL BE PROVIDED AND INSTALLED : BY L.S.P.. 2. OUTLET BORES TO BE 4' SQUARE MINIMA WITH SINGLE DEVICE COVER AN) TELEPHONE PLATE. 3. CODUIT RUNS FROM TELEPHONE BOARD OR MANAGER'S OFFICE FOR TELEPHONE AND DATA LINES TO CASHIERS ARE TO BE CONTINUOUS WITH ND JUNCTION BOXES EXCEPT AS NOTED OTHERWISE ON DRAWINGS. 4. ALL PULL WIRES ARE TO BE LABELED FOR PURPOSE DESIGNATED. 5. ND OTHER CIRCUITS ARE TO BE RUN IN SAME CONDUIT FEEDING ISOLATED GROUND RECEPTACLES. P. TESTS AND ADJUSTMENTS 1. ALL CONNECTIONS AT PANELS ABC SWITCHES ME TO BE MME, ALL SPLICESICOPLETE, ALL FUSES IN PLACE, ANDIALL CIRCUITS CONTINUOS FRE POINT OF SERVICE ERECTION TO ITS FINAL' DESTINATION, MD ALL COVERS AN) PLATES INSTALLED PRIOR TO TIE TINE OF FINAL INSPECTION BY,L.S.P.'S PROJECT MANAGER. 2. UPON OOPLETION. O THE WOO. ALL PARTS OF TIE ELECTRICAL'. INSTALLATION SHALL BE TESTED ND PROVED FREE OF UNWANTED GROUNDS AND OTHER DEFECTS. 3. ALL OVERLOAD DEVICES. INCLUDING EQUIPMENT FURNISHED UNDER OTHER CONTRACTS, SHALL. BE SET AND ADJUSTED TO SUIT THE LOAD CONDITIONS. 4. TEST A1ND MAKE CORRECTIONS/ADJUSTMENTS FOR PHASE BANGING. 5. THIS CONTRACTOR IS WI BALANCE TIE VOLTAGE LEAVING TIE STEP-DOW TRANSFORMER TO PROVIDE A SECONDARY VOLTAGE OF 120 MINIMUM TO 125 VOLTS MAXIMA BY ADJUSTING THE TRANSFORMER TAPS OCE ALL TIE FINAL CONNECTIONS HAVE BEEN MADE TO THE LON VOLTAGE PMELBOAHD.'. PROVIDE FINAL BALANCE REPORT TO L.S.P. PROJECT MANAGER AT TIME OF PUNCH -OUT. 0. CLEANING 1. AT THE END OF TIE PROJECT, THIS CONTRACTOR SHALL CLEAN ALL EQIIPRENT, INCLUDING LIGHT FIXTURES, TO TIE SATISFACTION OF L.S.P.. ALL OUST, DIRT, DEBRI, AND FOREIGN NATTER SHALL BE REMOVED FROM ALL EQUIPMENT. END OF SECTION 16050 o MAY 1 8 200 H- U z z 0 LLJ 1 O co z I- Q V 0 w 0 CO / J V I- w J w a Y CC CC a W en I- CC LU LU co > za 3 W WO) • 0- = o co • O Mt H CCCM Y CZ 4 M CO r 1 - J 011120 SHEET Z W U ES.1 ACCEPTABLE ALTERNATES FIXTURE KOHLER CRANE ELGER URINALS /7 -187 /161 -1090 SLOAN S186 SLOAN 5186 WC /1,3544 d 3-154 E /091 -4885 LAV rK1729 {1 -377 /051 -1358 FAUCETS /1,15199 - - P I LAP ING FI%TURFS NC WATER CLOSET AMERICAN MODEL /2168.100 (H.C) %3154E OR EL GER MODEL /091 85 IADEL LAV LAVATORY - AIERICAN STANDARD MODEL /0124.024 WITH FAUCET (H.C) F / FAUCET (MODEL /415199.) EQUALS 3-377 OR ELGER MODEL /051 -1358. MB MOP BASIN - FIAT $MSD -2424 MOLDED STONE MOP BASIN WITH VINYL BIUARD. FURNISH WITH AMERICAN STANDARD /9344.111 l FAUCET WITH INTEGRAL VACUUM BREAKER AND STOPS. EQUALS BY STERN-WILLIAMS OR MUSTEE. WH WATER HEATER - A.O. SMITH /ELJF -8, B GALLON. 1500 WATT 1205. , 1 PHASE. EQUALS BY RHEEM OR ROUT. FD FLOOR DRAIN - ZURN #Z415. 3' WITH NICKEL BRONZE STRAINER. (PROVIDE WITH TRAP PRIMER IF REQUIRED BY CODE OR SHOWN ON DRAWINGS). EQUALS BY J.R. SMITH OR WADE. RE DRINKING FOUNTAIN -OASIS WHEELCHAIR MOD EL PAM E P -TRAP WALL MOUNTED. FURNISH WALL HANGAR PLATE C ROM H ND D SUPPP L. ED S! O P. 1 " F ROM F LOUR ARD OUTLET. PROVIDED BY S.P. AND INSTALLED BY PLUMBING CONTRACTOR. FCO FLOOR CLEAN OUT - ZURN $21400 -HD-2 (CONC. FLOOR) OR ZN 1400 -2 (TILE FLOOR). EQUALS BY J.R. SMITH OR WADE. WHA WATER HAMMER ARRESTER - SIOUX CHIEF 750 SERIES OR EQUAL BY PRECISION PLUMBING PRODUCTS. INC. WCO WALL CLEAN OUT COVER - ZURN Z -1469. SINK SALES AREA SINK - FAUCET AND ALL TRIM PROVIDED BY L.S.P. AND INSTALLED BY PLUMBING CONTRACTOR. SEE DETAIL 'C' ON SHEET MD.1. SINK TO BE ADA COMPLIANT, KOHLER PORTRAIT COUNTERTOP LAVATORY (R- 2189 -8). 23" X 19' VITREOUS WHITE CHINA. FAUCET TO BE ADA COMPLIANT, KOHLER ANTIQUE CURIO FAUCET (K- 325 -4D CP), POLISHED CHROME WITH CURIO LEVER HANDLES, TRIM RINGS AND WTI POP -UP ASSEMBLY. PLUMBING CONTRACTOR TO FURNISH BRASS CRAFT 1/2" TWO WAY STOP VALVES (OR EQUAL). DE DRAIN PUMP/BASIN - ZOELLER /131 FURNISHED BY LOP. AND INSTALLED BY PLUMBING CONTRACTOR. FLOOR MOUNTED 5 GAL POLYETHYLENE BASIN WITH GASKETED POLYETHYLENE UD. BASIN CONNECTIONS ARE AS FOLLOWS: 2 NPT VENT; 1 1/2" NPT DISCHARGE; 2" NPT INLET. PUMP: ZOELLER PBS 115V., 10, 1/2 H.P., 1725 RPM, 25 GPM. 20FT. HD, U.L LISTED. PUMP PASSES 1/2 SPHERICAL SOUDS. ELECTRICAL CONNECTION TO BE MADE WITH 15 FT. U.L USTED 3 HIRE CORD AND PLUG. BASIN AND PUMP TEMPERATURE RATED TO 130F. UNIT IS FURNISHED WITH CHECK VALVE AND INSTALLED BY THE PLUMBING CONTRACTOR IN CABINETRY BENEATH SINK. VERIFY EXACT LOCATION WITH CONSTRUCTION MANAGER PRIOR TO ROUGH -IN. 1/4•_1' -O" PARTIAL PLUMBING PLAN 3/4" RISER NTS 1/2" TO SP (TYP OF 2) STACK NTS 4 1/2 ° DE IE 18 0 1 -- TO,D (TYP OF 2) RISER II � ^1,'V NTS L[ 0 ALL ROOM THERMOSTAT'S/TEMPERATURE SENSOR'S FURNISHED BY LSP. /CARRIER AND INSTALLED BY CARRIER.. CONTROL TECHNICIAN AT 48" ABOVE THE FINISHED FLOOR. 0 TEMPERATURE/LIGHTING CONTROL FURNISHED BY LS.P. AND INSTALLED BY CARRIER CONTROLS TECHNICIAN. 0 LOREN COCK MODEL /GC -180 TOILET EXHAUST FAN COMPLETE WITH INTEGRAL BACKORAFT DAMPER SHALL BE FURNISHED BY LS.P. WITH LIGHTING PACKAGE AND INSTALLED BY MECHANICAL CONTRACTOR. EXHAUST CAPACITY SHALL BE 150 CFM UP TO 0.825" S.P. CONTRACTOR TO FURNISH AND INSTALL EXHAUST DUCT, ROOF CAP AND ACCESSORIES AS REQUIRED. REFER TO PLANS FOR LOCATIONS INSTALL TOILET EXHAUST FAN IN LOWER DRYWALL CEILING. e R111-1 LS.P. SHALL FURNISH AND THE MECHANICAL CONTRACTOR SHALL INSTALL A ROOF MOUNTED ELECTRIC COOUNG/ELECTRIC HEATING HVAC UNIT. REFER TO "CARRIER ROOFTOP PACKAGE UNIT' PRINTOUT ON SHEET MD.1 FOR ADDITIONAL REQUIREMENTS. AWARDED CONTRACTOR MUST ARRANGE DELIVERY THROUGH KATHY CRECCO WITH CARRIER NATIONAL ACCOUNTS, AT (315)432 -7246, WITHIN THE FIRST WEEK OF CONSTRUCTION TO SCHEDULE DELIVERY DATE. CONTRACTOR MUST VERIFY MODEL NUMBERS AND ELECTRICAL REQUIREMENTS PRIOR TO INSTALLATION CARRIER MODEL I SGHJO4 UNIT OPERATING WEIGHT 1150 LBS 3650 C.F.M. SUPPLY AIR 600 C.F.M. MN. OUTSIDE AIR .60" EXT. STATIC PRESSURE 5.25 MAX BHP ALLOWED 480 VOLT, 3 PHASE, 80 HZ. 18.5 K.W. ELECTRIC HEAT MECHANICAL CODED NOTES FACTORY - INSTALLED ACCESSORIES 33CS- (APOLLO CONTROL SYSTEM) SMOKE CONTROL MOD2 CONTRACTOR INSTALLED ACCESSORIES FURNISHED BY LS.P.: FACTORY STANDARD ECONOMIZER /POWER EXHAUST ELECTRIC HEATER CARRIER MODEL 15GHJ005 UNIT OPERATING WEIGHT 550 LBS 1750 C.F.N. SUPPLY AIR 200 C.F.M. MIN. OUTSIDE AIR 0.8' EXT. STATIC PRESSURE 1.3 MAX BHP ALLOWED 480 VOLT, 3 PHASE, 80 HZ. 6.0 K.W. ELECTRIC HEAT CONTRACTOR FURNISHED AND INSTALLED ACCESSORIES THREE SETS STANDARD AIR FILTERS CONTRACTOR TO REPLACE FILTERS JUST PRIOR 70 AIR BALANCE AND ONCE AGAIN AFTER FINAL STORE CLEANING IS COMPLETE. ROOF CURB 24' CONTRACTOR IS RESPONSIBLE TO COMPLETELY INSTALL THE LISTED ACCESSORIES PER MANUFACTURER'S RECOMMENDATIONS, INCLUDING ALL ELECTRICAL AND TEMPERATURE CONTROL CONNECTIONS. 0 SUPPLY AND RETURN AIR DUCT CONNECTIONS TO RIO SHALL BE MADE FULL SIZE OF EQUIPMENT OPENING KITH FLEXIBLE DUCT CONNECTIONS AT UNIT. DUCTWORK SHALL BE INSTALLED FROM UNIT CONNECTIONS FULL SZE IN THE VERTICAL DROP FROM THE UNIT AND FOR A MINIMUM DISTANCE OF 6 FEET HORIZONTALLY AFTER ELBOWS. ELBOWS SHALL HAVE DOUBLE THICKNESS TURNING VANES INSTALLED. © THE MECHANICAL CONTRACTOR SHALL INSTALL CONDENSATE DRAIN FROM RPJ. MINIMUM DRAIN SZE TO BE 3/4". CONDENSATE DRAIN TO BE TRAPPED WITH A TRAP DEPTH OF 1.5 X UNITS TOTAL STATIC PRESSURE, MINIMUM 5" DEEP. DRAIN SHALL BE EXTENDED. AT A SLOPE OF 1" PER 40' TO THE SPLASH BLOCK. ROOFTOP/EXTERIOR PIPING SHALL BE U.V. RESISTANT PVC PIPING. PVC JOINTS SHALL BE CHEMICALLY GEARED. 0 DASHED UNE AROUND HVAC EQUIPMENT REPRESENTS MANUFACTURER'S RECOMMENDED CLEARANCES FOR EQUIPMENT MAINTENANCE. IT IS THE MECHANICAL : ONTRACTOR'S RESPONSIBILITY TO MAINTAIN SERVICE CLEARANCES THE FULL HEIGHT OF TIE UNIT IN THIS AREA AND TO PROVIDE ACCESS TO THESE AREAS SUBJECT TO LS.P. PROJECT MANAGER'S APPROVAL IF FREE AREA CANNOT BE OBTAINED IN THIS LOCATION, IMMEDIATELY CONTACT LS.P.'S PROJECT MANAGER FOR FURTHER ' INSTALLATION INSTRUCTIONS. CA SMOKE DETECTOR FURNISHED BY ELECTRICAL CONTRACTOR AND INSTALLED BY MECHANICAL CONTRACTOR, SMOKE DETECTOR MUST BE IN AN ACCESSIBLE LOCATION IN AIR DUCT. CARRIER CONTROLS TECHNICIAN TO WARE THE SHUT DOWN SEQUENCE OF THE HVAC UNIT UPON SENSING SMOKE. AND THE ELECTRICAL CONTRACTOR SHALL HIRE THE LANDLORD. INTERFACE TO SIGNAL THE MALL'S FIRE /SMOKE ALARM SYSTEM. REFER TO SHEET E -1 FOR FURTHER INFORMATION. WRING BY ELECRICAL CONTRACTOR AND FINAL CONNECTION. BY CARRIER CONTROL TECHNICIAN. ® FAN POWERED VARIABLE- AIR - VOLUME BOX FURNISHED BY LS.P. AND INSTALLED BY THE MECHANICAL CONTRACTOR. UNIT IS SUSPENDED. FROM THE STRUCTURE WITH IN- URE COMBINATION RUBBER AND SPRING VIBRATION ISOLATORS FURNISHED AND INSTALLED BY. THE MECHANICAL CONTRACTOR. CONNECT VAV BOX TO THE MAIN AIR DISTRIBUTOR SYSTEM AS SHOWN. REFER TO SHEET 60.1 FOR VAV EQUIPMENT SCHEDULE AND CONTROL INFORMATION. VERIFY BOX INLET AND OUTLET CONNECTION SZES AND INCLUDE DUCT. TRANSITIONS AND FLEX DUCT CONNECTIONS IN BID. BOX SHALL INCLUDE FAN INLET FILTER, FRAME AND DOOR INTERLOCK DISCONNECT SWITCH. MECHANICAL CONTRACTOR SHALL FURNISH THREE SETS OF STANDARD AIR FILTERS. CONTRACTOR TO REPLACE FILTERS JUST PRIOR TO AIR BALANCE AND ONCE AFTER FINAL STORE CLEANING IS COMPLETE. / 1 B nU-1 O SENSOR 11 VOLUME DAMPER FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. A 5020 -CC MANUALLY OPERATED DAMPER WTH 270 -275 CONTROL KIT AS MANUFACTURED BY YOUNG REGULATOR COMPANY, (216)683 -5646, SHALL BE ORDERED 3 WEEKS BEFORE INSTALLATION TO ALLOW FOR LEAD TIME. REFER TO SHEET MD.1 FOR ADDITIONAL INFORMATION. @ ALL WATER UNES VENT UNES. DRAIN ONES, SPRINKLER ONES, ETC. SHALL BE OFFSET BELOW PLATFORM AND CONCEALED IN WALL ABOVE PLATFORM. DO NOT ROUTE PIPING, ETC. THROUGH STORAGE SPACE ABOVE PLATFORM OR ABOVE ELECTRICAL EQUIPMENT. 13 CONNECT NEW SANITARY LINE INTO THE LANDLORD'S EXISTING SANITARY SERVICE. FIELD VERIFY EXACT LOCATION OF LANDLORD'S MAIN PRIOR TO BIDDING. INSTALL CLEAN OUT AT CONNECTION TO LANDLORD'S MAIN AND. COORDINATE LOCATION AND TYPE OF COVER REQUIRED TO MATCH FLOOR FINISH WITH LS.P.'S PROJECT MANAGER. REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. RUN AURER TO A MIN. 100' INTO LANDLORDS SYSTEM. 14 EXTEND NEW VENT THROUGH ROOF. REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. ©5 CONNECT NEW COLD WATER UNE INTO THE EXISTING COLD WATER TAP. NOTIFY LS.P.'S CONSTRUCTION MANAGER IF TAP IS SMALLER THAN SHOWN ON RISER DIAGRAM. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. © FURNISH AND INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND HOT WATER PIPING AS SHOWN ON THE WATER RISER DIAGRAM. WATER HAMMER ARRESTORS TO BE LOCATED IN AN ACCESSIBLE LOCATOR. UNITS AS MANUFACTURED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE. ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. RUN. ABOVE THE CEILING, 1'. 1/2" SANITARY, 1/2" DOMESTIC HOT AND COLD WATER FROM SINK ON SALES FLOOR TO TOILET ROOM. SEE DETAIL ON MD.1 FOR ADDITIONAL INFORMATION. CLEAN OUT TO BE LOCATED IN AN ACCESSIBLE LOCATOR. 1 1/2" SANITARY PIPE FROM SALES FLOOR SINK DOWN FROM CEILING IN WAIL. INSTALL CLEAN CUT AT BASE OF SANITARY RISER. VENT FROM SUMP TO BE EXTENDED THROUGH ROOF DIRECTLY OUTSIDE. OFFSET 2 -0" AND TERMINATE INTO 3" VENT THROUGH ROOF. NEW SANITARY LINE SHALL BE PRESSURE TESTED PER LOCAL CODES WITH A MINIMUM REQUIREMENT OF HOLDING 10 FT. W.C. FOR TWO HOURS. 24' X 12" CEILING ACCESS REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND ARCHITECTURAL SPECIFICATIONS FOR FURTHER INFORMATION. ACCESS PANEL TO BE USED FOR ACCESS TO EQUIPMENT LOCATED ABOVE THE CEILING. THIS CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT A MINIMUM UNOBSTRUCTED FREE AREA OF 3 -FEET VERTICALLY AND 2 -FEET HORIZONTALLY IN ALL DIRECTORS AROUND EQUIPMENT IS MAINTAINED TO ALLOW FOR INSTALLATION AND MAINTENANCE OF EQUIPMENT. IF THIS FREE AREA CAN NOT BE OBTAINED, CONTACT THE LS.P. CONSTRUCTION MANAGER IMMEDIATELY. VERIFY ALL CONDITIONS IN THE. FIELD PRIOR TO BIDDING. STRUCTURAL ELEVATIONS BASED ON: _FIELD SURVEY XXX LANDLORD INFORMATION _ STRUCTURAL DRAWINGS _ HEIGHTS UNAVAILABLE - ORE IS LOCATED ON LEVEL L OF FINISHED FLOOR TO BOTTOM OF DECK ABOVE IS APPROX. 15' -8"/ 14' -7" FINISHED FLOOR TO BOTTOM OF LOWEST STRUCTURAL MEMBER (STEEL OR CONCRETE BEAMS / JOISTS). IS APPROX. 14' -0" / 12' -11" AU. OTHER EQUIPMENT, PIPING, AND DUCTWORK ELEVATIONS ARE AS, NOTED ON THE DRAWINGS R,E,X,X,P,D,4,U,N,A NOTE: CONTRACTOR IS TO VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING WORK. ANY CONDITIONS THAT AFFECT THE INSTALLATION OF THIS PROJECT MUST IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTOR MANAGER OR BE INCORPORATED IN THE BID. DUCTWORK SHALL NOT BE FABRICATED OR ANY EQUIPMENT ORDERED PRIOR TO APPROVAL BY THE TENANTS CONSTRUCTOR MANAGER. inn Dilsz MECHANICAL CFNFRAI NOTES 1 THE ABBREVIATION LS.P. WHEREVER IT APPEARS IN THESE MECHANICAL AND ELECTRICAL DRAWINGS, SHALL REFER TO "UNITED STORE PLANNING, INC. ". ANY REFERENCE TO TENANT'S OR BATH At BODY WORK'S PROJECT MANAGER OR FURNISHED. BY ANY OF THE ABOVE REFERS TO LS.P. 2 THE CONTRACTOR FOR THIS DIVISOR OF HONK IS REQUIRED TO READ THE SPECIFICATIONS AND RENEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE. COORDINATION OF THIS WORK AND THE YORK OF ALL SUBCONTRACTORS WITH ALL DIVISORS OF WORK. IT IS THIS CONTRACTOR'S RESPONSBIUTY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3 ALL ROOF CUTTING, PATCHING AND FLASHING REQUIRED TO INSTALL THE MECHANICAL SYSTEMS SHALL BE BY A LANDLORD APPROVED ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. COORDINATE ROOF PENETRATIONS WITH LANDLORD AND GENERAL CONTRACTOR. 4 MECHANICAL CONTRACTOR SHALL INSURE THAT ALL EQUIPMENT. PIPING AND DUCTWORK, NOT BEING USED OR SHOWN TO REMAIN, IS FULLY REMOVED AND NOT ABANDONED. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. 5 THE CONTRACTOR SHALL FURNISH AND INSTALL IDENTIFICATION ON ALL ROOFTOP EQUIPMENT. PROVIDE PLASTIC LAMINATED PLATE OR STENCIL VATH 4" HIGH BLACK LETTERS INDICATING TENANTS NAME AND SPACE NUMBER. VERIFY ACTUAL REQUIREMENTS WTI LANDLORD. 6 FIRE PROTECTOR PLANS (SPRINKLER DRAWINGS) MUST BE ENGINEERED AND WET SEALED BY A LANDLORD APPROVED,, UCENSED REGISTERED FIRE PROTECTION CONTRACTOR IN THE LOCAL JURISDICTION. 7 CARRIER CORPORATION SHALL INSTALL A COMPLETE CONTROL SYSTEM TO AUTOMATICALLY CONTROL THE HEATING. VENTILATION AND AIR CONDITIONING EQUIPMENT AND UGHTING SYSTEMS AS HEREIN AND SHOWN ON THE DRAWINGS. LS.P. SHALL PROVIDE CARRIER CORPORATION ALL CONTROL SYSTEM COMPONENTS NECESSARY TO PERFORM THE INTENDED SEQUENCE OF OPERATOR, EXCEPT AS SPECIFICALLY NOTED OTHERNISE. SEE ELEC. DWG. 8 ALL 24 VOLT COMMUNICATOR AND /OR SENSOR WIRING ASSOCIATED WITH THE HVAC CONTROL SYSTEM SHALL BE PROVIDED BY CARRIER CORPORATION. INSTALLED BY ELEC. CONTRACTOR. ALL WIRING AND EQUIPMENT SHALL BE ACCORDANCE WITH THE LATEST EDITOR OF THE NATIONAL' ELECTRIC CODES, LOCAL CODES AND THE LANDLORD REQUIREMENTS. FINAL CONNECTOR BY CARRIER CONTROL TECHNICIAN. 9 CARRIER CORPORATION WILL PERFORM; STARTUP ON ALL LS.P. PROVIDED HVAC EQUIPMENT. AND CONTROL SYSTEM. NO TEMPORARY HEATING OR COOLING FROM LS.P. PROVIDED HVAC. UNITS HILL BE PERMITTED. 10 PRIOR TO START UP OF HVAC EQUIPMENT, MECHANICAL CONTRACTOR HILL CONFIRM TO CARRIER CORPORATION THAT. CORRECT POWER IS PROVIDED TO LS.P. PROVIDED HVAC UNIT AND HAS BEEN TURNED ON A MINIMUM OF 24 HOURS. MECHANICAL CONTRACTOR TO BE PRESENT DURING "CARRIER" STARTUP TO CORRECT ANY DEFICIENCIES IR THEIR WORK. THE CONTRACTOR IS TO INCLUDE 2 HOURS IN THEIR BID FOR THE STARTUP. MECHANICAL CONTRACTOR WILL BE REQUIRED DURING STARTUP TO ADJUST THE REFRIGERANT CHARGE ON ALL LS.P. SUPPLIED DX SYSTEM THE MECHANICAL CONTRATOR HILL BE RESPONSIBLE FOR FURNISHING THE REFRIGERANT, ALL TOOLS, LABOR AND MATERIALS REQUIRED TO ADJUST THE REFRIGERANT SYSTEM. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL STRUCTURAL STEEL REQUIRED TO SUPPORT ANY MECHANICAL EQUIPMENT.THIS CONTRACTOR SHALL COORDINATE LOCATIONS AND REQUIREMENTS KITH THE GENERAL CONTRACTOR AND LANDLORD PRIOR TO BID. 12 RETURN AIR GRILLES AT STOREFRONT TO BE ORIENTED TO PREVENT HEW INTO PLENUM FROM MALL ALL. OTHER RETURN AIR GRILLES ARE TO BE ORIENTED SO BLADE OPENINGS FACE WALL OR. SOFFIT. TO. PREVENT NEW INTO THE PLENUM. _- REVISIONS V ,K WIT}WUT PA �•YLA EUILDINV DIVN NOTE: ADDED RETURN AIR DUCTWORK AND REVISED SUPPULY CFM'S EACH DIFFUSER. FILE COPY G O 1 470 I understand that the Flan Check approvals are subject to errors and omissions and approval of plans does not authorize Me violation of any adopted coda or ordnance. Receipt of con- tractor's copy of approved plans x•U<nowledged. Pr!'ISION NO ti MP u 2 3 2L101 VERIFY ALL CONDITIONS IN FIELD PRIOR TO BIDS. MA I- 01& LU '.'0T' 222001 U z z z aJ a_ 0 H- h. Y cc W Q 0. CD oc CU 1114 3 wwc�) a C) Ei >C R OD N CC 0 NC to a g F' MECHANICAL/PLUMBING RESPONSIBILITY SCHEDULE LIEN FURNISHED BY INSTALLED BY &RED BY RNe1 N/A Rr7AARK5 DN.. LSP. mom cone usamolmme Name ems W.. ROOFTOP A/C SYSTEMS ROOF TOP UNIT • SIZE ', MOUNTING MATERIAL • DAR. BORDER STYLE • MOD. NECK Cu; C1: ROOF CURB FOR RTU STEEL ALUM. • SO -1 • 24'X24' 10 "• • •' STRUCTURAL SUPPORTS FOR RTU AS REQUIRED 8 • SD -2 • 24'X24 "..' 10'0 • • RTU T -STAT /SPACE SENSOR. • C SD -3 OMNI • 12 "0 • •. O ECONOMIZER AND UN I T- MOUNTED POWER EXHAUST • B SG -1 • 60'/6' 10'0 • • SEE MECH. NOTE 44 RTU ELECTRIC HEATER • A RG -1 355RL 24 "X12" 22"X10" • • RTU ALTERNATE MOTOR AND /OR'. DRIVE. PACKAGE B . • RG -2 • 24'X12" 22'X10" • • RTU -1 DISCONNECT SWITCH • C RG -3 • 24"X24" 22'X22" • • VAV SYSTEMS -LSP FURNISHED C RG -4 355RL VAV BOX • • • • 8 • SPACE TEMPERATURE SENSOR • • • DUCT TEMPERATURE SENSORS • • • SMOKE /FIRE SMOKE DETECTOR 0 REMOTE TEST STATION FOR SMOKE. DETECTOR • 0 REMOTE ANNUNCIATOR FOR SMOKE DETECTOR • O WIRING TO LANDLORD FIRE ALARM PANEL • WIRING TO SMOKE EVACUATION FAN • FIRE DAMPERS AND /OR COMBINATION SMOKE/FIRE DAMPERS • GENERAL CARRIER CONTROL SYSTEM COMMUNICATION BUS • • • 0 DIFFUSERS AND GRILLES • • LOW PRESSURE,DUCTWORK • • DUCH I GH/MED NM PRESSURE TWORK • ZONE DAMPERS • DUCT HEATER (5) • UN I T/BASEBOARD HEATER(S) • RELIEF AIR FAN • RELIEF AIR/MAKE-OP AIR MOTOR OPERATED DAMPERS • RELIEF AIR/MAKE -UP AIR MOTOR OPERATED DAMPER ACTUATORS • RETURN AIR FAN • OUTSIDE AIR INTAKE HOOD /FAN • STANDALONE SMOKE EXHAUST FAN • TOILET EXHAUST FAN • • • FURN WILTS. PACKAGE TOILET EXHAUST DUCTWORK • • ALL STARTERS AND DISCONNECTS NOT SPECIFICALLY MENTIONED ABOVE • • • AIR BALANCE REPORT • AABC OR NEBB CERTIFIED AS-BUILT DRAWINGS • PLUMBING FIXTURES • • SEE SHEET 0.1 DRINKING FOUNTAIN/WATER COOLER AND ASSOCIATED ACCESSORIES • • SAN, CW, HW. PIPING WATER METER • • 0, Ot Gr ,i,aONEa SPRINKLER PIPING AND • • 01 3 N 1601 FIRE EXTINGUISHERS • • IS n� -!,iMC LENERM SZIE -00,,.. 1M4 SOMULE IS INTENDED AS A'GAO, REFERENCE. ALL ITEMS 0BIFD HERE ARE SPECIFIED AND . DETAILED RE nE9EB CRAWNOS. ■ TIE DNIRACTOR DIC U 17EFIS THAT /R" E I M .P3 IC S MEN IT IS Ie3 TO Ri01a1 LB.P.S CONSiR11CllON NARAOER 50 MAT.liL3E mDA3 CAN BE CLAI•IED RESPOI CONTRACTOR. EON THE CON1RACiGIL O CARRIER TERMINATES coma. YWWO �- TITUS AIR DISTRIBUTION DEVICES DEVICES FURNISHED BY L.S.P. INC. WITH LIGHTING PACKAGE No.n.: 1. SGROL KEY - a DAMPERS SNWL BE OPERABLE FROM FARE FIRST LETTEa S -9WPLY R -RE URN E- E7NWgT A" OPPOSED BARE /AO-31 SECOND LETTER: o-OFf115ER R- IE•SIEIt 0 -:emir "A' R RD OR E CAC- 5. W/tgLUME COM"..1(X 2 CATAL00 NUMBERS REFER ID 71111S AR IIENCES b" YOUNG'S. REGULATOR. OFR MOO. R 5020 -CC 3.PRONDE .043 I1F MORAL BLOW Fat OT EI THAN . BORDER SINE - 4-WAY. K SURFACE MONIED.. 4. b" ,1 PROMCE WIN T7US NDEL /XY -13363 MANE A m1115 ] - um.) WRIE FOR I NF CERIIG NORQ 'B' TIlus V� - IIMIED MERLE - 0.G 70 FEUD PANT TO b' LAY-IN FRAME TOR T -BAR COMM CO Ta rs MAOM ll TNG OE BMOC WALL YP111 I M' FLASH .C,. 11MS le - MT SYMBOL CATALOG NUMBER SIZE ', MOUNTING MATERIAL INISH DAR. BORDER STYLE REMARKS MOD. NECK Cu; C1: OTHER STEEL ALUM. SO -1 OMNI 24'X24' 10 "• • •' 8 8 SD -2 OMNI 24'X24 "..' 10'0 • • B C SD -3 OMNI 24'1(24 " 12 "0 • •. 8 B SG -1 ML -39 60'/6' 10'0 • • 8 A RG -1 355RL 24 "X12" 22"X10" • • 8 B . RG -2 355RL 24'X12" 22'X10" • • 8 C RG -3 355RL 24"X24" 22'X22" • • B C RG -4 355RL 24'X24" 22 "X22" • • 8 B Design Weather Parameters & MSHGs Project Name: 120BBW PARKWAY Prepared by: M-Retail Engineering Inc Design Parameters City Name Location Latitude Longitude Elevation Summer Design Dry -Bulb Summer Coincident Wet -Bulb Summer Daily Range Winter Design Dry -Bulb Winter Design Wet -Bulb Atmospheric Clearness Number Average Ground Reflectance Soil Conductivity Local Tina Zone (GMT +/- N hours) Consider Daylight Savings Time Simulation Weather Data Air System Sizing Summary for 011120 SALES -NON /SALES Project Name: 1208BW PARKWAY Prepared by: M- Retail Engineering Inc Air System Information, System Name 011120 SALES -NON /SALES Equipment Class PKG ROOF System Type CAV/RH Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Space CFM Central Cooling Coil Sizing Data Total coil load 9.8 Tons Sensible coil load 9.2 Tons Coil CFM at Jun 1500 4310 CFM Max possible CFM 4310 CFM Design supply temp. 55.0 4F Sgft /Ton 306.8 BTU /hr /egft 39.1 Water flow O 10.0 4F rise - gpm Suppl Fan Sizin Data Actual max CFM Standard CFM Actual max CFM /sgtt Outdoor Ventilation Air Data Design airflow CFM CFM /agft ProJect Nana: 120BBW PARKWAY Prepared by: M- Retail Engineering Inc ZONE LOADS Solar Loads Wall Trona...Ion Roof Transmission Glass Transmission Skylight Transmission Door Transmission Floor Transmission Partitions Ceiling Overhead Lighting Task Lighting Electric Equipment People Infiltration Miscellaneous Safety Factor » Total Zone Loads Zone Conditioning Plenum Wall Load Plenum Roof Load Plenum Lighting Load Return Fan Load Ventilation Load Supply Fan Load Space Fon Coll Fans Duct Heat Gain / Loss >> Total System Loads Central Cooling Coll >> Total Conditioning Key: Sum of apace airflow rates Calculation Months Individual peak apace loads Sizing Data 4310 CFM 4241 CFM 1.44 CFM /sgft 810 CFM 0.27 CFM /sgft Air System Design Load Summary for 011120 SALES -NON /SALES DESIGN COOLIN COOLING DATA AT IN 1500 COOLING OA DB / WB 84.0 D Sensibl (8TU /h 434 23 389 115 Details 210 sett 870 sgft 3001 stt 210 sgft 0 egft 0 egft 3001 soft 0 soft soft 9483 W 6742 W 4800 W 33 10% / 105 1876 1808 1589 52 305 705 30. 4310 CFM 910 CFM 430 4310 CFM 256 0% - 11049 - 11049 11049 Positiv e values or clg loads Negative value. are htg loads 674 7416 8467 17 908 968 Project Name: 011120bbw parkway Rooftop Packaged Units Program Performance Summary Project Name: 011120bbw parkway Prepared by • M- Retail Engineering Inc Tag Nome: 011120rtu -1 Unit Name: 50HJ014 ARI EER 9.90 IPLV 9.8 Base Unit Weight 930 lb Base Unit Dimensions: Length 87.4 in Width 57.8 in Height 49.3 In Unit Voltage -Phase -Hertz 460-3-60 Air Discharge Vertical Fan Drive Type Belt Actual Airflow 3650 CFM Site Altitude 449 ft Condenser Entering Air DB 95.0 .F Evaporator Entering All DB 79.9 .F Evaporator Entering All NB 83.7 .F Entering All Enthalpy 29.13 BTU /lb Evaporator Leaving Air DB 54.4 .F Evaporator Leaving Air WB 52.9 .F Leaving All Enthalpy 22.07 BTU /Ib Grose Cooling Capacity 134.40 MBH Gross Sensible Capacity 116.32 MBH Compressor Power Input 11.56 kW Coil Bypass Factor 0.090 Electric Heating Capacity 18.50 kW NOTE: 2- Heater Modules Required External Static Pressure 1.00 in wg Options / Accessories Static Pressure: Electric Heater. 0.13 in wg Durablade 0.06 In wg Total External Static 1.19 in wg Fon RPM 972 Fan Power 2.7 BHP Number of Zones Floor Area Load occurs at OA DB / NB Entering DB / WB Leaving DB / W8 Coil ADP Bypass factor Resulting RH Zone T -slat Check Fan motor BHP Fan motor kW Fan static CFM /parson 6508 0 651 7158 7158 -266 8893 8898 8898 02/24/01 06:55 AM Seattle LAP Washington 47.5 Deg. 122.3 Deg. 449.0 ft 85.0 Deg 65.0 Deg 18.3 Deg 23.0 Deg 19.2 Deg 1.05 0.20 0.800 BTU /hr /ft /F 8.0 hours No Sensible Details (BTU /hr) 210 egft - 870 egft 2631 3001 egft 9256 210 sgft 6248 0 egft 0 sgft 3001 egft 0 egft 0 sett 0 0 0 0 0 10L 181 - 19948 - -3591 0 0 O 0 O 0 4310 CFM 0 810 CFM 6284 4310 CFM -2567 0 OS 0 - 125 0 0 Positive values are htg Negative values are clg 02/24/01 06:45 AM 2 3001.0 sgft Jan to Dec User- Modified Jun 1500 84.0 / 85.0 Deg 79.9 / 63.7 Deg 55.8 / 54.3 Deg 53.1 Deg 0.100 49 5 2 o 2 O 2.70 BHP 0.75 kW 1.25 In. wg. 24.90 CFM /person 02/24/01 06:45 AM DESIGN HEATING HEATING DATA AT DES HTG g / 65.0 Deg HEATING OA DB / WB 23.0 Deg / 19.2 Dag Latent ) (BT'.' /hr) Latent (BTU /hr) loads loads 0 0 0 OUTSIDE AIR REQUIREMENTS TOTAL SALES N -SAES FLOUR AREA SO. FT. 2311 'Mtn' D190E AR CM PER 'ON SG FT. RED. G30 0.15 103 R711 -1 707AL ACNAL OUTSIDE At PER UNIT 790 796 REMARKS 1 1/2 SANITARY SUE TO TOILET ROOM. SEE STACK. IN WALL (SEE RISER) - ��� 11 II VACUUM RELIEF BY P.C. 3/4 "J PLYWOOD PLATFORM BY GENERAL CONTRACTOR NTS Project Nome: 011120BBW Rooftop Packaged Unite Program Performance Summar Project Name: 011120BBW Prepared by • M-Retatl Engineering Inc Tog Name: 01112068W Unit Name: 5OHJ005 ARI SEER 13.00 Boss Unit Weight 445 lb Base Unit Dimension.: Length 73.7 In Width 45.0 In Height 33.3 In Unit Voltage -Phase -Hartz 3-80 Vertical Al, Discharge Vertical Fan Drive Type Belt Actual Airflow 1750 CFM SIte Altitude 449 ft Condenser Entering Alr DB 95.0 .F Evaporator Entering All DB 76.0 .F Evaporator Entering Alr WB 62.4 .F Entering All Enthalpy 28.20 BTU /Ib Evaporator Leaving All DB 56.6 .F Evaporator Leaving AIr WB 53.3 .F Leaving All Enthalpy 22.28 BTU /Ib Gross Cooling Capacity 45.88 MBH Grose Sensible Capacity 38.13 MBH Compressor Power Input 3.61 kW Coll Bypass Factor 0.221 Electric Heating Capacity 6.00 kW External Static Pressure 1..00 In wg Options / Accessories Static Pressure: Electric Heaters 0.17 In wg Total External Static 1.17 in wg Fan RPM 1199 Fon Power 1.3 BHP NOTE: Field Supplied motor and drive required. ROOF CEIUNG OR RECEPTACLE (BY ELECTRICAL CONTRACTOR) NTS 3" VENT THRU ROOF C.O. I I I I I I I 1 1/ 2" C.I. SAN. 2" C.I. VENT. IL I I SALES SINK DETAIL INSULATE ALL APING IN ACCORDANCE NTH SPECIFICATIONS I I I PIPES UP DRAIN VN.VE BY HW 1" DRAIN TO FLOOR DRAIN. WATER HEATER DETAIL VARIABLE AIR VOLUME BOX SCHEDULE VAV -2 CARRIER 4E4,4004 10'0 13'X73' 750 1050 1/4 277/10 B / 2 480/3 GAL% DRIP PAN BY P.0 DRAINS TO NOP SINK. INSULATED LOW PRESSURE FLEXIBLE DUCT AIR FLOW INSUUTED LOW PRESSURE DUCT TRANSITION TO OVAL OR RECTANGULAR DUCT SAME SZE AS VAV BOX CONNECTION 95M ELECTRONIC CONTROL ENCLOSURE WOL OLEAN OUT IS TO BE INSTALLED IN A LOCATION THAT IS BY A LAY-IN LAY -IN CEILING OR A 20 "X20" DIFFUSER A CHECK VALVE FURNISHED WITH UNIT. INSTALLED BY PLUMBING CONTRACTOR. UNION BY PC (1TP.) WATER HEATER SEE PLUMBING FlXNRE SCHEWLEA FOR AIXXnaNAL Kt. Y NUDE. 20. GA. SHEET METAL BAND, SECURE TO WALL FOR 5E15M1C BRACING WHERE R BY CODE (BY Y p.c.) MIN, CLEARANCE FOR ACCESS TO FAN • MOTOR - SECURE FLEXIBLE DUCT W/ ` DRAWBAND. SEAL CONN. AIR- TIGHT IN ACCORDANCE W/ 9MACNA STANDARDS VAPOR BARBER • INSULATOR SHALL BE INSTALLED OVER DONN. • SECURED VA ADD1. DRAW - BAND (TYP.) NOTE: DAMPER HANDLE TO BE INSTALLED MAXIMUM OF S -MY ABOVE COMM ( TO SA MAIN 18" LONG ORANGE MNMER TAPE ATTACHED TO DAMPER TO IDENTIFY LOCATION INSULATED FUMBLE CONNECTION (MIN. 3 FT., MAX 4 FT.) FIRE DAMPER THERE INDICATED ON PLANS TITUS MODEL "Dr DIRECTOR. BLOW PLATE CUPPED ON DIFFUSER ROOS. SEE NOTE BELOW SUPPLY AR DIFFUSER (LAY -N. FRAME) 25 1/4". 21 1/4', 19 1/4" OR 13 1f4" NOTE: ROUGH -IN OPENING SIZES: NOMINAL 12"x 12° - 12 1/2 "x 12 1/2" NOMINAL 24 "x 24" - 24 1/2 "x 24 1/2" NOMINAL 24 "x 12' - 24 1/2%12 1/2" NOMINAL 18 "x 16" - 18 1 /2 "x 18 1/2" NOMINAL 20 "x 20" - 20 1/2 "x 20 1/2" OUTSIDE DIMENSION L 23 ",19',17 "OR 11" INSIDE DIMENSION 24 ", 20 ", 18" OR 12" INDUCTION I fi r`B a DRYWALL MOUNTING FRAME DETAIL M0.1 NTS TOWNE DAMPER LOCATION WHERE DAMPER WOULD BE INACCESSIBLE AT TARE - OFF, PROVIDE W/ 3" EXTENDED SHAFT, HANDLE AND COLLAR NTS NOTE ALL DFFUSERS ARE 4-WAY BLOW UNLESS NOTED OIHERMSE PROVIDE 01 DRtEC11ONAL BLOW. TINS MODEL. 'Dr TO CONVERT DIFFUSER FROM STANDARD 4-WAY TO 1 -WAY, 2 -1 CR 3-WAY BLOW AS DESIGNATED ON PLANS BY SHADED AREA SHT. MIL ELBOW REQUIRED SECURELY TAPE VINYL FLEX DUCT TO SHT. MIL W/ MIN. OF (2) CONTINUOUS TRAPS OF DUC STRAP CLAMP OVER FLEX DUCT INSULATION • NW& TO MT. MIL TAPE INSULATION TO DUCT TO FORM A GOOD SEAL 8' LONG SHT. MIL SECTION (3) TO'. DIFFUSER COLLAR W / '.MIN. (3) SHT. MN. SCREWS. DUCT TAPE AND MASTIC MANSION FROM DUCT SIZE TO DIFFUSER NECK SIZE AS NECESSARY' THERMAL INSULATING BLANKET REWIRED FCR FIRE RATED CEILINGS ONLY. GRYWW.L CLG. STEEL MOUNTING FRAME REWIRED FOR DRYWALL Ct3UN0 INSTALLATION (11155 MODEL 4XY- 13383) DIFFUSER MOUNTING DETAIL AN. SERVICE CLEARANCE 3R' �IIIII►IIIIUl ®Ii MI11111111111. - II 4 x OA. MIN. LENGTH BALANCING TAPS INDUCTION OPENING ELECTRIC HEATER CONTROLS DISCHARGE AIR FLOW 1' UNED LOW. PRESSURE DUCT, TRANSITION TO DUCT SIZE SHOWN CN MATING FLEXIBLE CONNECTOR FAN POWERED PARALLEL V.A.V. BOX DETAIL NTS "C" CHANNEL REINFORCING BY G.C. AROUND OPENING MOUNTING SCREW FIELD INSTALLED DRYWALL CEILNG STEEL MOUNTING FRAME ALL DUCT LINER TRANSVERSE EDGES TO BE COATED W/ ADHESIVE SMACNA ACCORDANCE STANDARDS W / (TIP.) 1" ACOUSTICAL LINING- TAPE DOWN EXTERNAL INSULATION FASTEN 8/ MIN. (3) SHT. MTL SCREWS. SEAL W/ DUCT TAPE AND MASTIC ROUND RIGID DUCT 1" %RAPPED INSULATION--- - FLANGED AND GASKETED JOINT OR DUCT CONNECTION AND RE- INFORCEMENT IN ACCORDANCE W/ SMACNA 2" W.G. CLASS. SEAL NON- GASKETED TRANS- VERSE JOINTS IN ACCORDANCE W/ SMACNA CLASS "C" (1YP.) AIR CONICAL OR BELLMOUTH SPIN - IN FITTING, SEAL AIRTIGHT W/ MASTIC TYPICAL ROUND DUCT TAKE -OFF DETAIL NTS MAY 1 8 2001 H- NJ U z z z z 0 3 Y cc cc w a CC W W 00 wW C)) ED • 6 Gt1 In a • r H 011120 SHEET MDe1 CO 0K A. 2. 3. 4. 5. 5. $. NOTE C. TOES DIVISION 15 - ECHOIC. J. DNMITION SECTION 15000 BASIC IECNwICAL RQUIREWNTS ME ABBEVIATION L.S.P. WERE. IT APPEALS IN THESE WONMIC. DRAWINGS./OR SPECinc41106 STALL REFER ro 'LIMITED STORE PLANING, ITC.•. ANY REFERENT TO TIMM'S OR LERNER'S CONSTRUCTION WE. OR RINSED BY ANY a TE ABOVE REFERS TO L.S.P. DRAWING. GOER. PROVISIONS OF CONTRACT, INCLUDING GENERAL NO SIPPLOETfMY CWITIEG MD ALL OTHER SPECIFICATION SECTIONS. APPLY TO THIS ND TE 011. SECTIONS OF DIVISION 15. TE CONTACTOR FCR THIS DIVISION CF WOW( IS REQUIRED TO READ TE SPECIFICATION AHD REVIEW CRAW!. FCR ILL DIVISIONS OF WXK Ala IS RESPONSIBLE FOR TIE COMINATION OF THIS WOW( NO TE EN OF ALL SECONTACTCS WIN ALL DIVISION OF WGK. IT IS THIS CWIRORRS RESPONSIBILITY M PCVIDE THE SBCOTECiC6 WITH A COPLETE ET OF BID DDDIENTS. MIS OR RICRR IS ESF SABLE FOR SCEDULINC TE COMET. AW INSPECTION OF ILL CORK AND TIE NON Of TE 5NOONTWC.5 RORK TO OMIT WITH TE L.S.P. SGEDULE NO TE PROJECT COPIER. DATE. THIS CONTRACTOR .ALL VISIT THE sITE PROW TO SUENITTAL OF BID TO DEE:WINE DWITIOLS NTECTINS TIE ERE. ANY ITEW WSIT ARE HOT COVERED IN TE BID DODXENTS Ct AS FROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY NO QU.IFIED 91 TE CONTACTORS BID. SWITTAL OF BID GALL SERVE AS EVIDENCE OF ITELEDGE OF EXISTING 00DITIONS NO MY WOIFICATIOS NI. NE REWIRED TO MEET TIE'TIENT CF TE DRAWING NO SPECIFICATION. FAILUE M VISIT 110 SITE DOES HOT RELIEVE TW CONTACTOR OF RESPONSIBILITY IN PERFORM E OF EN. REFER TO RESPONSIBILITY SCHEDULE ON 11E FECANICA DRAW. FOR INTXJATION IN REGARD ro RESONSIBILITY a CORK OR IT. WSIIR MAY AFFECT BID. B. GENERAL EQUIRDENTS T. mis =mu, aR SOIL PW'DE ALL L.., MATERIALS, ECIRENT, SERVICES, TOOLS, IMMEPORTTION. UNCLE. AND DETAILS ECESS/RY ro PEOVIDE A DEPLETE WWNICAL SYSTEM AS SHAW ON TFE ORATES, CALLED FOR IN THE SPECIFICATIONS, NO AS REQUIRED BY JG TIDITICb. ALL ERR NT SPECIFICALLY NOTED AS BEING BY TIE IRO., WRIER CWT. TECNICIM, C( L.S.P. SHALL BE RWIDED BY THE ECWNICAL CONTRACTOR. CLOSELY COORDINATE TE ENTIRE INSTALLATION WITH TIE LNMOHO AD TIE L.S.P. PROJECT INTER, AS REQUIRED. 2. THE ERNS. MO SPECIFICATIONS AE INTENDED TO SPREE. EACH OTER AIO ANY MATERIAL CR LA. CALLED FOR IN ONE SHALL BE RUNISIED MD INSTALLED EVEN 7110.1GH NIT SPECIFICALLY . TESED IN ECM. MN MATERIAL CR LABOR M. IS HEIR. SHOWS ON TFE DRAWING NCR CALLED FCR IN THE SPECIFICATIONS, MF 1H1 IS OBVIOUSLY NECESSARY TO DEPLETE TE MCP(, NO YLIICN IS US ALLY INCLUDED IN NM OF SIMILAR CHARACTER, SALL BE FURNISHED MD INSTALLED AS PART OF CXNEM, 3. WERE RE OWINGS OR SPECIFICATIONS CALL FCR ITEMS TM EXCEED GOOFS CR TW LANDLORD'S TENANT CRITERIA, TE OCNTRACTOR IS RESPONSIBLE KR FURNISHING MD INSTALLING THE SYSTEM WITH THE CORE STRINGENT REQUIREMENTS AS DESRCFD AD DESCRIED ON THESE CRANKS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL EORMICAL mum smcc N INSTILLED HO AS TO BE BEADILY .fESSIB.E FIR OPERATING, SERVICING, MAINTAINING, AGE REPAIRING. THIS CONTRACTOR IS RESPJSIB.E FOR PROVIDING SUFFICIENT SERVICE .ESS TO AL EQUIRERT. ALL RO K SHALL BE PERKEED IN A NEAT PROESSIQAL EWER USING 000 ENGINEERIE PRACTICES. ULFSS SPECIFICALLY NOTED 0110E15E,'UTERI.. PRWUCis, Ale EQUIPMENT, INCLUDING ALL COMMENTS TEREOF, 94ALL BE NEW, U ERMITERS LABORATORIES LISTED ND LABELED NE SIZED IN CEKRMITY WITH REQUI.:N75 OF STATE AND IOC. CODES, WIICNEMR IS HOE STRINGENT. 1. ALL VON SALL CNOJJ TO THE LTC/C IS' CRITERIA, TIE STATE'S, CONNTY'S, CITY'S I1D LOCAL 0.5 NO ODINMOS, SAFETY MO HEALTH COTS, NEPA CUES, ENERGY CODES MO ALL 011. APPLICABLE .ES AHO REQUIREMENTS. IRIS DETRACT. 911LL INQUIRE INTO AND CPPLY WITH ALL APPLICABLE DOES, DRDINMCFS, MD EGAATICS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY DENS IN TE BID AM IF THESE CNWGE S ME NOT INCLUDED IN TE BID, THEY MST BE W.F. AN A SPARATE LINE ITEM IN TE BID. AFTER CONTRACT IS ISSUED, M MDITIDNN. COST DE TO 300E ISSUES SHALL BE REIMIItSED BY L.S.P. TO TIE COITEMR. D. LICENSES, KNITS, INSPECTION L FEES I. =I TS. R SPE C SOIL DETAIN r PAY FOR ALL LI CENSES , PEWSITS, INSPECTION, I!O FEES REQUIRED IR ELATED ro THIS EN. 2. FURNISH TO TIE L.S.P.'S PROJECT IMAGER ALL CERTIFICATES OF INSPECTION ,LAO FINAL INSPECTION APPROVAL AT COPLETION OF PROJECT. E. TRADE SAES. WMAACNFERS NO SHOP MEM. WEE TAME toms MD ILD.ADA.E. rJff USED ON TE mum. OR IN 17E SPECIFICATIONS, TE EXACT MIREAT SHALL BE USED AS A MINIM FOR TE BANE BID. MAMFACMERS CONSIDERED AS EQUAL CR BETTER IN ALL ASPECTS TO TAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY L.S.P.'S PROJECT IDNAGERANGIIEERIND WOOER PRIM THROUGH SHOP DRAWING SEMITE. PROCESS, FIR N%EPTMCE. TE USE OF MY WNTOORIED EQUIPENT SHALL BE SUBJECT ro MOVE ND EPMAENT AT THE CONTRACTOR'S EXPBSE. 2. GEER. CONTACT. SALL 503JIT ELY MBSTIMION EQIESTS TO L.S.P. PROJECT .NIGER FOR APPROVAL. SW/155I06 SALL BE HYDE EARLY 0.11 IN PROJECT TO ALLOW FOR (4) IENING DAYS FOR L.S.P. PROJECT WAGER% REVIEW WITTWT CASING DELAYS CR COMICTS TO TIE JOB'S PROFESS. 9M /ITTNS GNALL BEM TFE STNA OF TE 14ER. CNTRACRR I1D Tf 9E- CONTRACTOR SHOWING TAUT E HAS REVIEWED AJO COWIN. THAT TE SUBMITTALS ARE IN COMENCE RIM TE CONTRACT 'PARINGS NO SPECIFICATIONS CR INDICATE WERE EXCEPT'. HAVE BEEN TAM F. MINUMEE 1X15 cammTIR SHOP. Gum.. ALL MATERIALS Na wow PROVIDED UNDER THIS CONTRACT AHD SHALL ATE COD, REPAIR OR REPLACE AT CONTRACTOR'S Ofl EXPENSE, MY DEFECTIVE von. MATERIAL, OR =IRE. ETCH MAY BE DISCOVERED WITHIN A PERICO a 12 KNEW ROM 110 DATE OF .EDEN CE (IN WRITING) OF 700 INSTALLATION BY L.S.P.'S PROJECT MANAGER. EXTENDED WNRMTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIREJN. 2. L.S.P., ION. GALL TIARANTEE AL EQUIPMENT ENE CNKIER DENiCL .SES HAVE BEEN ISSED. L.S.P. SELL PROVIDE A COPIER 1210TH MARTY FCR ALL PARTS ON EQUIRERT PROVIDED BY L.S.P., INC. //D L.S.P.'S LAGOON. THIS CONTRACTOR SHALL NT BEAR .ITIONAL WARRANTIES BEYOND A COWETE 1.1. STEM, MD AN .H, HO ADDDITIONAL NE NES 9MU BE SEWED IN TIE BID. G. RECORD'PANINZ T. THIS conomMR STALL MAIRTAIN OtE copy oF CAWIMS oN TE JOB SITE TO RECORD DEVIATIONS FRP COMACT ERMINE. SUCH AN: A. LOCATION OF CONEALED PIPING VALVES AO ODES. B. REVISION, .OIDU6, AND CHNCE CADS. C. SIGNIFICNT DEVIATIONS OW NECESSARY BY FIELD CIDITI06 APPMVTD EQUIPENT SBSTIMICS, AGE 0E.CTON S.RDIHATION WITH OTHER TRIES. 2. AT DEPLETION OF TIE PROJECT AND BEFOE FOWL APrYWAL, TE =RAC. SHALL WE MY FINN. CORRECTION TO CRAVINGS NO CERTIFY 7NE .PRICY OF E. PRIM BY SIGNATURE THEREON. OE COPY OF THE NET r aw SET OF DRAWINGS WITH KWEROVE MT MA SALL BE FUIED IN A DIMING .E LOCATED NEXT TO RE E ELECTRICAL MEL. SE ARCHITECTURAL DRAW. FIR EXACT TIDE LDGTICN. H. DI.EPTCIES IN.01E NIS 1. CROWS (PUNS, SPECIFICATIONS, ,LAO DETAILS) NW DI. OHMIC NO INDICATE NERAL TE TE G LOCATION AN INTENT a TE WCMICAL SESTETS. WEBS NAVIES. EXISTING SITE CODITIC6, SEECIFICATIOS NIP. OTHER TRADES COFLICT OR AW UNCLEAR, ADVISE TE GEWN . TNERACIOR IN VRITING, PRIOR TO 5111111. OF BID. TE TEO/ CONTR.. IS RESIN. E TO ADVISE L.S.P.'S PROJECT WEER, IN YRITIW, OF VARIATIONS TO CONTRACT MEETS PRIOR ro SLORSSION OF BID. OIERNISE, L.S.P. PROJECT ONA ER'S INTBBRETATION OF CONTRACT DOOLENTS OR MIT. SHOP. BE FINAL NITS ND Am ITIMIe MCFMATIM MINAITIFII I. POSING RETIREER.S ( NOT APPLICABLE ) 1. THIS CONTRACTOR IS TO INCLUDE IN HIS BID ALL NECESSARY SEINICE REQUIRED ro MEP 71E OPERATING RASE OF TE STELE'S NV., FLEMING AO SPtINO.ER SERVICE IN OPERATION. CONTRACTOR MIST .ECU LE !N WRITING WITH L.S.P. PROJECT MANGER NO TE LAFDLOND PE BED( PRIOR TO ANY CAR MIN OF Tr Mat R I W 11Y: AB FJBA' RMTFMI1)N iYCTFK 1. THIS compACTQI SHALL BE ESPONSIBLE FOR 7NE CXRSINATION a TIE DEMOLITION OF EXISTING.1( NO TE.3LITION PROVIDED BY THE GEN CONTRACTOR. COORDINATE WITH TIE GENERAL ccourrIR ANY EXISTING EQUIRENT REWIRED TO BE LEFT INTACT. 2. MIS CONTRALTO( SHALL INCLUDE, MO WILL BE HELD RESPONSIBLE FOR, THE REMOVAL a ALL EXISTING FIRE PROTECTION, PLUMING Forms, PIPING, HVAC WITS, REFRIGERANT ECAPTRE, EMU. ERNS, ETC. NO ASSOCIATED ROOF CURS NOT TOE REUSED ON THIS PROECT, UNLESS SPECIFICALLY NOTED °ETERNISE. CONTRACTOR MST VERIFY WITH THE LANDLORD ALL F E.. MVOONED =ARENT, PIPES, oucovoE, AND ECUIRENT PRIOR TO RDOV.. ROOF CUES SHALL E REMOVED NO NE ROOF PATCHED. ALL EXTRNMOJS ITEMS IN THE SP. OR ON TE TOLE NOT APPLICABLE TO THE NEW WOK MGT BE REMOVED AND ROOF/WALL/FLOOR PATCNED(IEPAIRED TO MA. EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS, OR EMINENT IN THE ROOK, EMBEDDED IN CONCRETE, CR OTHERWISE INACCESSIBLE ME 70 BE CUT OFF NO SEALED BELOW Pi WITHIN FLOOR CR WALL LEVEL WEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD CR ODES, MATED PIPING NO/OR DUCTWORK MST BE REMOVED TO POINT OF ORIGIN. COPIES! THE EMIT OF DDM ITION PRIOR TO BID Na INCLUDE IN BID K. SLEEVES 2. 3. L. HANGERS 2. 3. 4. M. FINAL WIC INSPECTION END OF SECTION 150C A. SOME OF CONK 2. B. ECIRENT AND INSTALLATION 3. 4, 5. 7. e THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT ECIRENT OR FACILITIES IN TE INSTALLATION. EACH SLEEVE SHALL E %TES TROUGH IT'S RESPECTIVE ROON, WALL OR PARTITION NO SHALL BE CT RUN WITH EACH SRFALE EXCEPT SLEEVES TAT PENETRATE THE ROOK, WSDON SHALL EXTEND 2' MOVE TE FLOOR. CONTRACT. MST [ORDINATE TERN. TE LANLOND ANY CORE DRILLING OR CUTTING OF .KING IN MASONRY ROOKS OR WALLS. ALL SLEEVES NO O hIING THROUGH FIRE RATED WALLS AND/CR FLOGS SHALL BE FIE SEALED WITH CALCIUM SILICATE, SILICE 'REV FOAM, 1 3/ • FIRE RATED SEALANTS OR OWL, SO AS TO RETAIN THEIR FIE RATING. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AID PARTITIONS SHALL BE SEAWARD WEIGHT STEEL PIPE FINISHED WITH 900111 EDGES. FOR OTHER THAN MASTNO PARTITIONS, THROUGH SUSPENDED CEILING, OR KR COCFALM VERTICAL PIPING, SIEVES MALL BE E. 22 U.S.G. GALVANIZED STEEL MINIM /. MEW SHALL INCLUDE AL 111.LLANEOUS STEEL SUCH AS HOLE IRON, DAMS, OCPMS WITH RETAINING TIPS, CHANNELS, GER RCS, ETC., ECESSMY FOR TE INSTALLATION a MOM. HANDERS SHALL BE FASTENED TO BUILDING STEEL, CCETE, OR MAMMY, BUT NOT TO PIPING. HANGING FRO/ WEAL CEP IS NOT PEWITTED. HANGERS MST BE ATTAOED TO UPPER COD OF BM JOIST. MERE INTERFERENCES OCCUR, ND IN ORDER TO SUPPORT DUCTWORK CR PIPING, TE CONONTRACTCR MST INSTALL TRAPEZE TYR HAILERS CR SUPPORTS WILE STILL BE LOCATED WERE THEY CO NOT INTERFERE WITH ACLSS TO FIE DOPERS, VALVES, AND OTHER EQUIPENT. HOWER TYPES NO INSTALLATION IETNCS ARE ALSO SUBJECT TO LNOLCD CRITERIA. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED ND INSTALLED FCR THE OUTER DINETER OF INSULATION. INSTALL 5' LOG SPLIT CIRCLE GALVANIZED SADDLE FETA. 7E HANGER I!O 711E PIPE INSULATION. MASERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELECTRICALLY SEPARATED. ASIDE FROM NORMAL INTERIM INSPECTIONS OF MOM IN PLACE, L.S.P. SHALL HAVE AN &DEPENDENT HVAC CONTRACTOR INSPECT THE FINISHED HVAC INSTALLATION UPON COPLETION FOR COPLIMCE WITH TE PLAN, SPECIFICATION ND CODES. TE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPCTFD BY THE INEFEMENT NV. CONTRACTOR UP TO PLAMS AND SPECIFICATION RETIIREMENTS. DIVISION 15 - ECHMICAL SECTION 1520 PLUBDHO 1. THIS COMRADE SHALL FURNISH ALL LIBOR, MATERIALS, ETIIFMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY AMR OED MD INCIDENTAL T0, THE FURNISHING. INSTALLATION, COPLETION AM TESTING OF ALL WORK FOR THE PLUMING SYSTEMS AS SOWS ON 11E DRAWINGS, CALLED FOR IN TE SPCIFIGTIOS, NO AS MIRED BY JOB CMITIOS, TO INCLUDE, MT NOT BE LIMITED 70 7IE FOLLOWING: A. CC PLETE SMITMY PIPING SYSTE S OF WASTE, MAINS, Ate VENTS. B. COPLETE CTS NO NOT WATER PIPING MEOW APPURT APPURTENANCES AID INSULATION. FIIm1RES N NATURAL GAS PIPI NG AN G ED. SYSTEM ( KKR PLANS). GS PHO MTFAN N4LICI8LE, E. WOENSATE PIPING STEM (AS APPLICABLE, REFER TO PLANS F. TSSTS ). NO ANJUSiWXTS. BEFORE STARTING MOK, THIS DETRACTOR SALL EXMIE THE ARCHITECTURAL, STMLTWAL, MECHANICAL NO ELECTRICAL PUNS AND SPECIFICATIONS TO SEQUENCE. COORDINATE, NO INTEGRATE THE VARIOUS LLDENIS OF THE AIMING STEM, WTERIAL9, MO EQUIPENT WITH OTTER CONR.TOS TO AVOID INTEEEROCFS AND CO TENTATICS. RELOCATION OF EXISTING WATER, CAS, WASTE, VENT. ON DRAINAGE LINES TO FACILITATE STORE DESIGN CRITERIA MST BE INCLUDED IN BID PROPOSAL. EFER TO PLANS FON noi sy .ES a EQUIP T AO FU TES. A.PTAB STNOAED, KCU.FR ND CRANE ME C NSIC BWD ILCEPTANLE AN EQUALS. 2. SMITIRY PIPING A. WASTE, DRAIN MD VENT PIPING SHALL BE SERVICE SEIM CAST IRON MIL PIPE. VENT PIPING MOVE FLOOR 2 OR WALLER MAYBE GALVANIZED STEEL. ALTERNATE PIPING MATERIALS ARE ACCEPTABLE AS A SBSTINTION WEN THEIR USE IS PEROTTED BY THE LANDLCD, LOCAL CUES AND BUILDING DEP/STRM OFFICIALS NO CUES NOT AFFECT OTHER TRADES. SUBSTITUTION MST BE LISTED MD QW.IFIED IN BID. B. INSULATE ALL NDRIMMAL ROE OF PIPING LOCATED IN CEILING SPACES OF TFNAMS IN SP.FS BELOW, WEN APPLICABLE. IMULATIEJ TO BE AS SPECIFIED FOR RA101 PIPING. C. CONDENSATE PIPIW SW.L BE TYPE 'L' DRAW COPPER TIKE WITH D5-6 TIN -M DENT SOLDERED JOINTS MO TROD. COPPER FITTHCS WITH DIELECTRIC SEPMATION la_TTVEEN DISSIMILM WEALS. POTABLE WATER PIPING SALL BE AN FOLLOWS: A. BELOW GRADE: TYPE 'K', NEEALED TYPE TOTEM CPPFR TRIBE FCR PIPE SI7ES 2 IMXES MO SMALLER. BRAE ALL JOINTS. B. ALL OTHER: TYPE 'L' DRAWN .PER 71113E WITH WROUGHT COPPER FITTING AID 95-5 TIN - ANTIMONY SOLDER PIPIW AT a ED. DISSIMILM WEALS MUST BE DI-ELECTRICALLY SPM GENERALLY, SENT. AND POTABLE WATER TAPS WILL BE PROVIDED BY TE LANDLORD. FIELD VERIFY EXACT DEJECTION POINTS PRIOR TO SUBMITTING BID A) NDTIFY L.S.P.'S PROJECT MMMLER IF CWITICS ARE HOT AS SHOWS ON THE PANS OR AS STATED IN THE SPECIFIGTIES. DETRACTOR MST VERIFY I E OPERABILITY OF ENTIRE SYSTEM FRI. TOTIE IN AS FOLLOWS: A. StM E SANITARY FORA DISTANCE a 100 FEET NO REPORT ANY BLOCKAGE. B. TEST WATER PRESSURE TO INSURE MINIMA: PEI MATOE� DENNING EQUIPENT SUPPLIED. IFSUUTE ALL HOT WATER, COD WATER NO TWESATE PIPIW WITH 1' ITT( (Kt0.23Il 75 •F PIE INSULATION Wro AN A l ERVICE WCRET ro MEET L 30A L Aro UL FLANS SPEND TO STONE DEVELOPED RATING. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES DOER LAVATORY WITH 1/2' AR6TREG • ASYFLEX • PIPING INSULATION OR MACRO MODEL IOW NNW LAN TINA' INSULATION KIT. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARDERS TO SUPPORT ALL PIPING AND FIXTIIE KS S. HAC SHALL 5019 999 SUIT TYPE OF PIPING PROVIDED NO BE SPACED AT A MAXIM/ SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WEE REWIRED BY CODES. STERILIZE WATER STEP) IN.ORDOCE WITH LOCAL TOES. CLEAR -OUTS NO FLOCK DRAINS SHALL BE INSTALLED PER LOCAL CODES. OPAL COVERS ARE TO BE STAINLESS STEEL ND FLOOR COVERS ME TO BE BRASS. PROVIDE FLOOR COVES WITH INSET AREA FOR CNPETED LOCATIONS. ALL CLEAFTIT LOCATIONS MALL BE APPROVED BY L.S.P.'S PROJECT MANNER. 11. ESCUTDEOS SOLI BE CHEM RATED, SIZE AS REQUIRED AO PLACED AT ALL PIPE MEDIATIONS AT WALLS, ROMS. ND CEILINGS IN FINISHED NETS. 12. LEMAN TESTS SHALL BE PER LOCAL CODES, MINIM/ AS FOLLOW: A. TEST WATE PAM' AT 106 PS&G FOE NOV. TEST DR SAS7E, VENT PIPING Br A 1' WATCR OOLIIX FOR 1YU LOCOS. 13. FLASHING SAIL BE SEALED WATERTIGHT MO PEECR1ED IN TO TI ACCORDANCE E LMMCD's CRITERIA. USE A INDIGO OWED ROOFING COTTACIOR WEE NPLICMLE. 14. PROVIDE WATER DETER NO RE ARE READER PER LAJOLO D'S CRITERIA OR LOCAL UTILITIES ERANDEES IF APPLICABLE. REFER TO PLANS TO DElOM1E IF WATER ETER IS REQUIRED. C. 000 PIPING ( NOT APPLICABLE ) 1. FUWTSH NO INSTALL A DEPLETE CAS PIPING E STE1i IF APPLICABLE. REFER TO PING TO DETERJIE IF A CAS SYSTEM 15 REQUIRED. 2. GAS LINES SAL BE MAO( STEEL. SCERAE 40, ASK A -120. WITH WLLEIBLE F ORD FITTING EON 2 ND SMALLER, ND WITH WELDED JOINTS ALTS RR 2-1/2' AND LARGER. 3. FURISN MO INSTALL A CIS COP. DIRT LEG, ND ONION COJECTION TO EACH PIECE OF CEMENT. 4. PITCH PIPING AT A WIFPK GRADE OF I/O IN 15 FEET IPMEO 10 DIRECTION OF ROW. SUPPORT PIPING EVERY 5 FEET. SERIE AS REWIRED BY LANLCRD CRITERIA. AS DETAILED ON DRAWINGS, OR BY STM.D INDUSTRY PRACTICE, WHICHEVER IS MORE STRINGENT. 5. ASGPIPING%OEDON EDGEMSTBE PAINTEDWITHRUST- IMIBITIHO PRIM. m CAN PIPING INSTALLED IN ERN AIR RLMWS 9WL E SEEYED NO VENTED CR VEINED IN .0RON CE WITH TIE LOCAL GAS COPANY, LOCAL ODE, NO APPLICABLE EPA 54 GOES. 7. TESTING MD RACING OF GALS PIPING MALL BE OM PER THE RECIETEES OF TE LOCAL GAS COP., LOCAL CORM NO APPLICABLE NPA 54 ODES. B. COACT AND CPDINATE GAS SERVICE, METER NO RENA. ECUIPQEMS WITH TIE LOCAL CAS COP. ND TEE ALL'S OPERATIONS IT/AGT PRIOR TO BID. INCLUDE INSTALLATION CONE OF SEAS IEIER NO REOLATCR IN BID. END OF SECTION 15200 C. MIRE. ND INSTALLATION DIVISION 15300 - KONICA/ SECTION 15330 FIE POTECTION A. SCEs voK i. TNS CNIR/LTOI MST UBE A LAN.. AR DT. F..... =MC. TO PERFO/ ALL FIE PROTECTION WOK. ALL COSTS MST BE - INCLUDED IN THIS CONTACT. BID. FIE PROTECTION CONTRACTOR NST CORY WITH ALL SECTIONS OF THIS SPECIFICATION NO I.WE SEE IN BID. 2. THIS CONTRACTOR SHALL FUNISN ALL .01T. MATERIALS, MIRES, SERVICES, TOOK, MWERTATION NO FACILITIES ECESSNRV FOR, REASONABLY IMPLIED AND INCIDENTAL TO, TIE FUWISHIM RTNI , INATION, COWS. ND TESTING OF ALL 7TE TEM FOR THE 9RIIJGER SYSTEM AS SHOWS ON THE DRAWINGS, CALLED FOR IN RE SPECIFICATI06, AND AS REQUIRED BY JOS CODIT106, ro MICE, RUT MT BE LIMITED M THE FOLLOWING: • INSTMIATION a NER ET SPRINGER sYSTEN AS REQUIRED TO PROVIDE COVERAGE IN . C.NCE WITH EXISTING CONDITIONS, NEPA -13, LOCAL CCES, UFMOD'S CRITERIA, AND MEW. CARRIERS KR TE MALL ND LIMITED. B. EMS, RISERS, LATERALS, TAVEL VALVES, ALMS, SPRINGER ANDS ND ALI DEPONENTS REQUIRED FORA C. DESIG OEPLETE N MAWINGS, FTERMLIC CALOLATICIS, MAMMALS AHD APPROVALS. D. PEWITS, FEES, AM CORES. E. TESTS MD TEST IFICATES. F. FIE EXTINDUISit.. 3. BEFORE STNNIFE NDR( THIS CNTRL7DR mo L Ems. THE .HITECTWIL, 51MCTRAL, WOWICAL . NO ELECTRIC. PUNS AO SECIFIGTIOS TO SEQEACE. COORDINATE, NO ',ITERATE THE VARIOUS ELEMENTS OF RE FIE PROTECTION SYSTEM, MATERIALS, NO ETIIPENT WITH OVER CONTRACTORS TO AVOID INTERFERE CFS ND COMMENTER.. WRRAGTOR SERI USE /PARTED INDUSTRY FIE SPRINGER SWORDS FOR REUSING EXISTING FIE SPRINGER TAO. NO S SUIT C.0 L TICS ro L.S.P.'S PROJECT WEER UPON REQEST CR REEN SYSTEM TO L.S.P. PR JELT ANGER'S SATISE.TION. 4. REL.ATi.OP EKISTIND WINS LATw., BUNGFS NO RISES ro FACILITATE STORE DESIGN CRITERIA MST BE INDEED IN BID PROPOSAL. B. MP ORES. 1, 7X15 FIRE PRawn.. CNI. SHALL PI dI SAILED N AIa SHOP CRA S COL.OLA UTIOS NOON FOR HIS . SKT SIX (5) COPIES ro GENRAL DETRACTOR FIR A ROT.. 2. MIS FIRE POTECTION ONIRACTCR IS RESP061B.E FOR S UITTING CWWIN. MEOWS. HYDRAULIC G CUUTIE6, BEAD TYPES NO COOS TO AL MUTHICRITIG HAVING JURISDICTION FOR IPROVAL. NO I. SHILL BEGIN UNTIL ALL ANIMAS HAVE BEEN RECEIVED. 3. A =ry a TW LETTER . APPROVAL K. THE ...Ws INSURANCE RATING BUREAU SHALL BE KNEADED TO TE MIME'S AGENT AGE TO L.S.P.'S PROJECT WNMER. I. SPRINGER WM: A. ALL SPRINGER Eus SHALL BE NEW (EXIST). WADS IN EXIST. L.S.P. STORES ARE NIT TO BE EPL.D UNESS OPTED OTNDTNISE), U.L. F.N. LISTED ND 0.0. ...TIC MAY TYPE AS UWPACIUED BY con. SPRINKLER CO., E.gBE, GNINELL, RELIABLE, STAR, CR VIKING. B. ALL SPRINGER TADS SAL, BE RATED KR 155 PUSS INDICATED 071 ON DRMINZ CR REC IF. BY LOCAL COGS. C. ALL SAES FLOWS HEMS ARE m HAVE E FAT. .PRIED COLOR FINIS/ VERIFY WAD TYPES NO CEOS WITH L.S.P.'S PROJECT ANNER ND SUNIT WITH SPRINGER DRAWING FOR PEWIT. D. SPRINGER FRAD TTTES ma BE AS KILL., I. SALES AEA SPRINGER 10. NW M BE WHITE RECESSED PRO. WITH MITE ESCNOEON. BASE BID 900.0 BE RELIABLE WDEL • FI'. ATBSAIE BIZ MAY BE BASED ON VIKING MICOATIC MEL It OR CRINELL IEOEL • FLrz • ND MAST BE MEDVED BY TzE L.S.P. CONSTRUCTION I/ I ER PRIOR TO ORDERING MO IN EALLATION. 2, No... AREA BRINGER UNSUNG AE ro E PEDANT TYPE ROUGH BRASS FINISH. AMF.TWED BY STAR, RELIABLE, GRINELL. VIKING CR CENTRAL SPRINGER 2. PIPIW: A. SCHEDULE 40, RAC( STEEL PIPE, AST I ANT FOR FERROUS PIPIW, TOED AND SENLESS, NS' B#1.70 FOR NOUGHT STEEL PIPE B. CAST IRON CR NII I F IRON SCREED FITTINGS KR PIPES 2 (NOES NO SMALLER. WEED CR COST IRON FENCED JOINTS FIR PIPES LMGR TAN 2 IN... C. CALVM12ED OR !LAO( INLLEMLE IRO6 WITH BRASS .T SCREED UNION KR PIPES 2 SEES MO SMALLER. D. VICTNLIC TYPE COWLINGS ME ACCEPTABLE, METE MOVED BY TOE NO Tie LANG.. A FIE PROTECTION SYSTEM TM IS TELTALLY FLENT ED BY THE UHMO O. VERIFY IN FIELD PRIOR TO BID. SPRINGER SPACING SHILL KT MOE. 130 90. FT. IN "SALES' MEAN NO 100 S0. FT. IN 'SEDEC TEAS. COALE WITH LNOLOD'S DESIGN CRITERIA NO LOCAL CUES IF ILK STRIAE/ff. PIPE SIZING SELL BE BASED ON *PA ORDINARY HAZARD. 4. ALL mi.. LINES SAIL BE INSTILLED DE6ffiALED, .MIDIND INTERFERENCE WITH LIONS, DUCTS, PIT'S, STORAGE ECK, ETC. FIRE P OTECTIP CORM. SHALL FIUME COCDINAM SHOP CREMES IMICATHE TE LOCATIES OF ALL SE MLER IVES, SPRINGER LIM. LIONMS, DIMMERS, GRILLES AND REGISTERS (RICK TO INSTTLATION. 5. wow Pww., FEWJR( RE Eris,. SWINGER SYSTEM ro BEET TIE HEN REMIRDE 1 S 61 THIS DESIGN. ELOCATE ALL MAINS AND MANCE5 &TENERING WITH CEILING WIPES, EQUIPENT, Me MAJOR COMPERES 'ELUSIVE a .JTNT TENNIS AND MALL OGJON AREAS, AIME ALL MEAN PIPIW. O. FUNGSH MD INSTALL. A VALVED TEST COMOROS IN M .CESSIBLE LOCATION FOR THE SPRINGER SYSIFFI AS REQUIRED OR EDESTFD BY TE ALL, LOCAL IMPEDE, CR INSURMEU MEER. COORDINATE LOCATION WIM L.S.P.'S PROJECT MANNER AN LOCAL FIRE PROTECTION OFFICIAL PRIOR TO RTIG- IN. 7. WEN COPI.ETC, 1)W ENTIRE FIRE PROTECTION PIPITS SYSTEM SIWL BE MO STATICALLY TESTED AN REQUIRED BY TEE RUES REGULATIONS OF TE MiHOtITIES HAVING JURISDICTION. SYSTEM GALL SHOW NO SIDS OF LEAKAGE CR OTHER DEFECTS. THIS CONTRACTOR SHALL BE RESPOSIBLL FOR DACE TO 700 WdK v 100 OTHER °ENACTORS OR TO TW BUILDING, OR TO ITS • S, PEOPLE, ETC., CASED BY LEAKS IN Of OF THE €00IP6 EOUIRENT INSTALLED BY NUN. ALL REPAIRS OR REPUTE. OF DEEMS STALL BE AT THIS CONTRACTOR'S EXPENSE. B. PROPERLY COPLETED ND SIGFD •SPRINKLER com .TOR's MATERIAL AND TEST CERTIFICATES SHALL E FMCISHEP TO TIE LNOLCIE, EMERITIR HAVING JURISDICTION, NO L.S.P.'S PROJECT MMNFR. 9. SPRINGER HEADS LOCATED IN CEILINGS OR WALLS BELOW 8' -0• NU E THE FINISHED FLOW MM ABOVE STORAGE DECO ME TO E CONCEALED. 10. FINISH NO INSTALL 10 LB. TYPE • ADC • FIRE EXTIl ISERS WITH CABINETS IF REQUIRED. AND AT LEAST A • 2AIOSC RATIIO. LOCATIONS TO E ESTADLISED IN THE FIELD BY L.S.P.'S PROJECT YMGER NO TE LOCAL FIE PROTECTION OFFICIAL. AMIN TRAVEL DISTNCE BETWEEN EXTINGUISHERS SHALL E 75 FEET OR LESS AS REQUIRED BY LOCAL COOTS. END OF SECTION 15300 DIVISION 15 - IECANICAL SECTION 15500 .TING, VENTILATION, NO AIR CONDITIONING A. .PE OF WPB 1, THIS CCNRACiCR SHALL .41. ALL LABOR MATERIALS, EQUIPE., SERVICES. TOOLS, TRNRPORTATION AND FACILITIES ECESSMY FOR, REASONABLY IMPLIED NO INCIDENTAL TO. THE FURNISHING. INSTALLATION, COPLETION NO TESTING OF ALL TE NO FOR THE E WI CIC SHOW SYSTEMS AS ON TW DRAWING, CALLED FOR IN TE SPECI FICATIORS. ND AS REQUIRED BY XS COM E ITIOS TO INOU . BUT HOT BE LIMITED TO Tic FOLLOWING: A. B. D. E. F. HV. WITS, ECIRENT, NO APPURTENANCES ( ULESS NOTED OTHERWISE). DUCYNCK, FITTING, DAP.. NO INSULATION. NYCRONIC PIPING. (AS AMICABLE, REFER TO PLANS). REFRIGERANT PIPING (AS APPLICABLE. REFER TO PUN). CRC, ROOFING. NO STEEL FRAMING FOR SUPPORT (AS APPLICABLE, REFER TO PLANS). TESTING. ADJUSTING. ND BALANCING. 2, COORDINATF. WITH CARRIER CENCI TELTNICIAN INFORMATION ON TE FOLLOWING: A. TEMPERATRE CONROS NO ELATED DIRT MS. B. SECENGS OF OPERATION. 3. BEFORE sTMTIHG WORK TIES cwt.. stALL VISIT TE JBBITE NO EXAMINE TE AR211TECTRAL, S1RD1UAL, 66000 IECHARICAL NO ELECTRICAL PUNS AND SPECIFICATIONS TO SEOIIDCE. 00DINATE, AID TE TE VMIOG EMITS OF TE HIV. STEM, MATERIALS, . 9696 ND EQUINES MITI OTHER EXTRACTORS TO AVOID INTERFERENCES NO CONFRONTATIONS. A RELOCATION oF EXISTING DUCT WINS IR URNIOFS ro BEET wow DESIGN CRITERIA MST BE INCLUDED IN BID PROPOSAL. B. INC EQUIR6RT 1. KIROV EATING AND AIR CODITIONING WITS IE TO BE FURNISHED BY L.S.P. AS SCHEDULED UNLESS WEED ITEMISE. REFER TO PLANS FIR ECIROFNTS..L EQUIREMT STALL INGLOE A FIVE 5) TOR DEPRESSOR NO TEN (10) YEAR HEAT EMMET 2. ALL EQUIRLRT 600L E DEPLETE IN EVERY RESPE9T WITH ALL DEVICES. APARTEUN:ES, ND.ESSOTIFS PROVIDED TO BEET THE DESIGN INTENT AND OPERATION OF 110 SYSTEMS SON CR TE DRAWINGS 'ND SPECIFIED HEREIN. 3, EQUI06T STALL BE INST.LED IN 510)01 ACODAMLE 6)10 THE IJWFICIAER'S INSTRUCTIONS. NL. AIR CONDITIONING EQUIPENT OUST BE TRAPPED IN ACORDANCE WITH .JF.TU E S DATA. WE MEANINGS CR ADDITIONAL DETAILS. 4. SECOND. DRAIN P. RAE RECITED ro BE INST.LED BEIEATI ALL INDOOR AIR COOITIONIND ECIRENT WITH THE EXCPTION OF VAV OWES. SECCNDMY PALS IRE TO PROTECT ENTIRE WIT. PR VIDE CO ENSATE PUPS, AS REQUIRED. DIDa6ATE SHALL BE DIRECTED TO ADP SIN CR AS SPECIFIED ON PLANS. C. ECIRENI MISTED 131 LIMITED STPE PLANE. 1. THE FOLGXING 60116 11 IS FINISHED BY L.S.P. MO IISTALLE0 BY THIS CONTRACTOR IALESS SPECIFICALLY ANTED OTHERWISE. REFER ro RESONSIBILIEY SCHEDULE ND PLANS FOR APPLICABILITY. A. HVAC WITS B. TOILET EXHAUST FNS. C. w5FBW1D, CABINET NO WIT HEATERS. D. DIFFUSES, GRILLES NO RESISTERS. E. TE TD C P N ER CI TE CONTROLS (COORDINATE TIM CANRIA COW.. ALL DI (. r TT N CMS RE CESSMY 7 PWIDE A DE INSTALLED TOILET S C O ORE. SHALL BE FIRNISWD NO INSTALLED BY MIS CONTRACTOR. E. METAL DU RE. - ND FIBERGLASS DUCT ALLOAED 1. NO DUTTON SHALL BE FAMICATED PRIOR TO JOB SITE VISIT ND APPROVAL BY THE GENERAL CNTRACTRR. A PITCH MST BE SMUTTED INDICATING SIGNRFICAM CEVIATI06 FRW DESIGN NO NAT BE APPROVED BY L.S.P.'S ENGINEER PRIOR TO FORINT!. OR INST.LATION. 2. EXCEPT AS OTHERWISE INDICATED, FABRICATE NO INSTAL RECTA/CULT NO REIN DUC111OK WITH GALVANIZED STEEL, IN . ORDMCE WITH META 'NV. DOLT CONSTRUCTION STAMENS' OF THE LATEST EDITION. MERE OVER CODES ARE SACRED, (IE. WC. 1330A, ETC.) USE THE HOST STRINGENT CBE FOR DUCT DESTRUCTION STANDARDS. 3. EXCEPT WERE OITERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO TIE FOLLOWING MSSRE CLASSIFICATION: SUPPLY DUCTS: 2' W.G., POSITIVE RETIRE NO EXHAUST DUCTS: 2' 00.6., NEGATIVE EXCEPT WERE °ITEMISE INDICATED, USE DUCT SEALANTS OP THE FOLLOWING PRESSURE CASSIFICATIE6: SUPPLY DINTS: CLANS B - 3 w.. REARM ND ENVOI DUCTS: CLASS C - 2' N.. IN ACCORDANCE WITH MESE DESTRUCTION MO SEALANT PRSSUM CLASSIFICATIONS, wXINE DUCT AIR LEAKAGE WILL NOT EXCEED 511 AS REWIRED KR FIN. AIR RALNKE IPPI60VAL. 4. ROOT DUCTEN SHALL BE GALVANIZED STEEL WITH SPIRAL LOOSEN) COSTRUCTON FOR NE ALL SIZES 14' DITER NO LARGER. RUE. DUCT. SIZES 13' DINETER I D STILLER MAY BE SNAR- L= CCSTRILTICN. ALL SOP-LOCK SFAS SHALL BE SEALED As DESCRIBED IN TESE SPECIFIGTIC6. ROUND FITTINGS SHALL BE Gg.VAN12ED STEEL WITH SPOT WELDED NO BODED OR TACTION. DUTTON SHALL BE AS War CREED BY MIRED .ILL, SEND, Ct APPROVED EQUAL. 5. ROCO SPIRAL GALVANIZED STEEL DUTTON MAYBE USED IN RACE OF RECINOLTR DIDTWR( WEN MOVE CEILING CLEARANCES PERMIT NO EQUIVALENT FREE AREA IS MAINTAl1ED, WITH TE FOLLOWING EXCEPTION; ALL SUPPLY NO REM DUCTWORK WITHIN 15 FEET OF THE AIR NNMER NAT BE RECTA/STAR ND INTRALLY LINO. WEE WOO DUCT SUBSTITUTION WILL THE PUCE, SMUT A SETCR ND CART SEWING ECIV.ENT WOO 60 OS OF RECTANGULAR DUCT. TO L.S.P. DOREERING MANMER'S FOR APPROVAL PRIOR TO FIB ).TIN OR INSTALLATION. AN A MAIM D ALL ELAT / URGES IR EINORCE NIT. A BEM ENT VIBRATIONS, 7/8' WIDE X 3 OF DEEP ON 12' KSi1TFA5 TO PREVENT YIBRATIOS. RECNDLF55 a GILT GAIFE. 7. INSTALL FACTORY wMP.TWED OCHE MICIOESS TUNING VANES IN ALL RIGHT AME ELBOK OVER M IN LOGTH. INSTALL FAC78RY /ANWACTTRED SINCE- TXIDO. TUNING VNFS IX .L OTTER ELBOW. 8. INSTALL RIGID REND NO RECTOS°. WEAL DUCT WITH SPPIRT ESTEE INDICATED IN SAQA STNNiDS. SUPPORT RORIE.. DUCTS WITHIN 2 FEET OF E. ELBOW NO WITHIN 4 FEET OF EN. BRACH INTERSECTION USING K RE STRAP HM6ERS ON EACH SIDE a FITTING. SIPPEKT VERTICAL DUCK AT A MAXTOR INTERVAL OF 15 FEET Al AT EACH F.R. NO IR. SALL BE ZED M SIPPER OR BR. DUCES. PROVIDE MAY NO SEISMIC (RACING AS REQUIRED . BY STATE NO LOCAL ODES OR BY LNMOND. 9. WERE DUCTS PASS THROUGH ROOFS AND R.0.5. PROVIDE AS MINIM/ 1- 1/2'X1 - 1/2'X1/6' STEEL ANTE ERNES AT EACH SIDE CF OPENING. TE S SPACE BE*WEED ES D. NO NEE FRX GA 6110 I LL E.0 LRJED WIT SLICIE SEAL. OR 'FIEPCOFED AS REWIRED BY ASSDMY FIRE RATING. 10. .L JOINTS AND SEPIAS SHALL BE SEALED WITH r WIDE. SUSS - FIBER- FABRIC REINON9D 000 JOINTS ALSO SALL BE RIVETED T CR =WT. WITH SHEET WEAL SCREWS. LIQUID VAUNTS BY UNITED'ICOILL CRP., DOW CONING, MIRA AQESI VES RIO smarms inc. . WILL k maPm, IX LIM OF TAPE. 11. SOFT 590) BUM GASKET WITH E.SIVE BACKING SHALL BE 10 .I ZED TO SEAL sumo Jonas. 12. DUCT TRNLSITIOS STALL WT EXCEED 30 DEGREES SICK EXCEPT AS SPECIFICALLY NOTED OTHERWISE. 13. PROVIDE 0. SS TO ALL HO DUTTON DOPERS, FIRE ONPDS, CARROLL NO OTTER DU R IT. IN THAT REQUIRE SERVICE CR INSPECTION. IF TE ACCESS PART LOCATION IS EXPOSED TO TE SALES MFR, IT COST E .PROVED DE L.S.P.'S PROJECT IMAGER PRIOR TO INSTALLATION. LAY -IN SPRY ND RETURN AIR DIFFUSERS, GRILLES ND REGISTERS WITH PLANTER ERNES MAY BE USED AS ACESS LOCATIONS WEN WITHIN 3' -0' OF DEVICE. MECHANICAL SPECIFICATIONS 14. ALL DUCTWORK SAU. BE INSTALLED WITH INSIDE CLEM DIMENSIONS AS PANED ON DRAWINGS. WERE DUCTEN SIZE IS URGER NM CONC. DEVICE (IE. VAV BOX, DIFFUSER, REGISTER) .30TH DUCT T AISITIOS ARE TO THE RACE JUST FRIOt TO DEVICE ONECTIQI. REFER TO DETAILS. F. WDIW PRE59AE DIOT 1 NOT APPUCABLE 1 T. NFAE OIICIWQJK IS SPECIICALLY NOTED AS RS D. PS., IT E E SHALL =SEWED IN ACTROWE WITH MALWA SMOOT FOR A PEE. RATING OF 4 WO ER dLILN ES WATER /IN1MW OR GREATER AS EW )RED BY LNOLGB. 2. ALL 6AUGE5 NO REIIF7RLBE1IT NET NET TRH TE LATEST EDITIIR OF SACRA SWORDS FOR WORN PRESSURE DUCT NO WITH TE UIOLOD'S CRITERIA. 3, BE OE WIN L � � � sxAL BY CORP.. CR AS OT EIN'ISE EWIED BY TE LANDLORD. 4. ALL ENTER 1TENS 1)1006 METAL OIICIIQK SPED11)1GT1ON 509()96 APPLY TO THIS SECTION, WITH THE EXCEPTION TAT ALL 'EDIT' IRESSUM OIICIIAWI MST E NAPPED INSULATION, NT LINED. G. VIBRATION ISOLATION DEVICES 1. VIBRATION ISOLATION DEVICES SHALL E FU NOSED NO INSTALLED IN ALL B1WF1.6 VIBATIN6 DRUM. (FAILS, AIR TIROL., , 01001.) ETC.) NO STRUCTURE. 2. VIBRATING EGUIRENT RIG FROM STRUT. BULL BE )STATED WITH RIMER NO SRIN DEVICES. VIBRATING ETRE. SUPPORT. FRON R.= OR DEO( GALL BE UNDATED WITH NBEED SPRING 10. DEVICES. 3. KATE DEAD LOUD NO OPTATIW LAND DEOITIOS MEN SELECTING DEVICES. ADJUST FIR PROPER .INENT ND LOIDIW. AVOID 'CREWING' TE ISOLATOR. 4. CEO( HOC. RD SIZE FOR .008LE LOOS AT TE 'STATING DEVICE NO AT 1 E AWED MO LOTT ATTAOWPNIS TO STMCTPES, DUCTS, EQUIIEET, ETC. 5. CONSULT MAN.E.TIRFR FOR /ARLIE -110N DATA. N. FLEXIBLE CCXFCTIO6 I. FLEXIBLE COLTS .LL BE FUXISIED NO INSTALLED IN ALL =KELTIT6 BE7'EEN VIBRATING EQUIPEW (FNS, AIR SWUM, ETC.) NO WOK IR cams. ALSO, FTRII MD INSTALL FLEX dX1ECf MERE DUCTS CROSS MICIND EXPNSION JOINTS. 2. FLEXIBLE =WECT106 SALL BE CONSIN TED OF 16981E-00ATED FUNS ROOF FABRIC. PROVIDE /BEQATE JOINT REXIBILITE TO ALLOW FOR MVEI.F NO PREVENT TE TRM98SSION OF VIBRATION. I. FLEXIBLE AIR DUCT 1. FLEXIBLE AIR COT MALL BE 1' INSULATED CLASS 1 MD RATED FOR THE OPERATING PRESSURE OF TE SYSTEM. DUCT COMMOTION MATER). ( PLASTIC, FLOUR, ALUIMM) MST ACFRE TO Loc. ODES 060 LAWN. RETIREMENTS NO BE INCLUDED AS SHOT IN TE BID. 2. FLEXIBLE AIR DUCT SHALL BE ATT.ED PER DETAILS ON DRAWING 10-1. FLEXIBLE AIR DUCT MAY OLT BE USED IN VERTICAL MPLIGTI96 WITHGR PRIOR APPROVAL FROM L.S.P.'S PROJECT MUER UNLESS MED OREM.. 3. FLEXIBLE DUCT SALL NOT EXTEND OCR 5' -0 IN LENBIR AT ANY OW LOCATION. J. SUPPLY AIR TAE-CFF PIETIES 1. REUSS ND INSTAL COMA/ OR . ELL THE -ORS FAW 006)6 WIN MIMIC TO RRRO IN NCIES. INSTALL TALL P PER MWXFALTUER'S 1161ROTIO6 AND DETAILS ON SLEET YY1. K. DNPFl6 1. 2. FUXIGN NO INSTALL YAWL LOWE 9600006(0 VOLUTE WM. DAMS WITH NTEE OPERATORS AS W. ON 8066 TO FACILITATE AIR BALANCING. OPERATING FUMES ON ALL &MRS SHALL BE TAMED WITH A MINIUM 18' LOG CRANE INNER TIPS. COLLARS MST BE INSTALLED OVER EXTORT/ INSULATION TO ALLOW FEE INDENT. SE NOITICW/ DETAILS GN IMMICAL DETAIL OWING. 3. METE moos TO BAL.!. DMPER IS REPRICTEO, A TONG'S REQLATOR DEMO SMALL BE USED. CONT. TONG REVUE. DEPNR AT 2151553 -6545. 11T5 $ALLL BE OOBE1 THE 'Ea6 I T TO N1QI FOR DEI.IVFRY LEON E. L. FIE DMPEE ( NOT APPUCABLE 1 1. FINISH NO INSTALL PRIMARY FIE DIAPERS WERE INDICATED OR RECITED BY CODES. DOPERS SAIL E DESIGNED FDR MIWITAL OR VERTICAL FLOW OF AIR AS REWIRED. FIR DMPOS WALL BE UL LABELED ND REEF ALL 030E EOUTEENR. 2. FIRE DNPEBS STALL HAVE THE BLADES TIT OF 1E AIMEE* NO A 15•F RISIBLE LINK, TYPE B. AS MINI./. FINISH NO INSTALL ACCESS DOORS AS NECESSARY. 3. (00X141 NO INSTALL ALL NETS. 9 FRAMING NO SLEEVE FOR ONPCR WRING PER I. NO TOE MOMENTS. 5E DETAIL ON SHEET /0-1. U. WTWEK INSULATION T. RAKISH AD INSTAL wooly. ROSCIS m AC0.QUM"..E' WITH MNLi.IER'S WRITTEN INSTRUCTI06, AN IN . ORDE E WITH RECZIMO INDUSTRY PRACT'CF9. INSULATION COST CORY WITH EFTA WA. 2. DUCT SIMS SCOW ON WRINGS A/E INSIDE CLEAR DIMIS1OS. ALL SPRY AND RETURN AIR RECT. DULTWAN SHALL E INTERNALLY INSULATED WITH 1 TEE 1 -1/2 LB. DENSITY LINER (0-0.28 • 757). MEN A COPLETE DUCTED REIM AIR ME M IS INDICATED ON RE DRAWING ONLY TEE 1W -0' OF TE RENW AIR DUCT CLOSEST TO TE AIR IWd.IND UNIT IS TO BE INSULATED. LINER IS TO HAVE A COATED SIEGE EXPOSED TO AIRSTREAM TO PREVENT ERIEIGN. APPLY ....IVES AND KONICA. FASTENERS AS REC MEN ED BY SIENA ND TE WMFACIURR TO PREVENT LINER SEPARATION PROM THE MCI. ALL MA,'SL'. EDGES TO E COATED WITH APESIVE. 3, ALL woo ENT., QUTSIDE AIR Cm.. ND MEDICO PRESSUE DUCTWORK SHALL BE EXTERNALLY INSULATED WITH A MINIMA/ OF 1 1/Y VAAKR RAP IS TO BE DEAN. WM "& T&NONROUT DUCT STEM. ALL JOINTS MST BE TAPED SD THAT NO IIMATION FIEF IS VISIBLE. EXTEND DUPE. INSULATION WITHOUT INTFRSPTION M EM WALLS, FLOORS, NO SIMI. PENETRATION. 4. ALL INSIATDON GALL NAVE A FLANS SERGD RAT. a NT HOE TUN 25 YO AS.iE REELED REIM M HIM THAT'. WM TESTED IN ACM.. WITH ASTM C 411, CR AS REWIRED BY LOCH. CCES. 6. XYCRONIC P1P1W ( NOT .APPLICABLE ) I. FINISH ND INSTALL A COPLETE NOWNIC PIPING STEM IF APPLICABLE. REFER TO PLANS TO DETENTE IF A MORONIC STEM IS REQUIRED. 2. PIPING A. NTORONIC PIPING FOR CHILLED WATER, WOB6ER WATER mom HEATING WATER SI. BE A5TI/ A-120, 40, ERN. BLACK STEEL PIPE WITH PLAIN ENDS. INSTALL STEEL PIPE WITH MELDED JOINTS MERE PIPE IS 2-1/2 HC NO LARGER. INSTALL STEEL PIPE WITH THREADED JOINTS ND FITTINGS CR INSTALL TYPE 1 11 1 AMPLER TEMPERED COPPER THEE WITH SILFCS .DINTS FOR 2 INCH NO SMALLER PIPE, PROVIDE DIELECTRIC .106 BETTE. DISSIMILAR METALS. .L PIPING SHALL BE IN STRICT 16 64) E WITH .STN, ANA, MD LNMOD'S EQUIEAFNTS. 00 WEEVER 15 MOST STRINGENT. UNIONS OR RAMS MAT BE USED AT EPAIRENT ALL E PIPINNG MO EQU0 WI I I CE S W . V1) w0 BE T W17NOLR LFAKME AT A MINIM/ PRESSNE OF 125 PSI. ALL EMETIC PIPING AND EQUINES =EC. ro TE 11VAC PIPING STEM SMALL BE CLEANS o, RUSHED. REMOVE, CLEAN. AID REPLACE STRAINER SCREENS. FILL TENANT'S STEM WITH DOPSTIC WATER NO VENT ALL PIPING ND EQUIPMENT PRIOR TO MOTION TO TE LAtalms STY/!. CONTRACTIR SHALL NOT FILL TEES'S STEM WITH WATER FEU. LNOLCPO'S STET UNLESS SPECIFICALLY INNS. TO DO M FEW THE IR O'S FIELD REPRESENTATIVE. D. PRIOR ro DONECTIIR To THE LNOLOD'S STEM, COMET. SHALL OBTAIN WPITTFR CONFIRMATION FROM 100 LNEOD'S FIELD REFRESDITATIVE, THAT ALL TESTING, WEN I NFLE W TED INS F 100 Cf THE LNOLQDS 9 ALAS REW IRENE 015 NO THAT DE TENANT'S STEM IS EDDY ro BE CONNECTED TO THE CANTO M SYSTEM. B. C 3. VALVES A. GATE VALVES, .1. AND SMALLER: CLASS 150, BOOT AID UNION BONET OF AST/ B 52 CAST BONZE WITH TNREMED OR SOLDER ENDS, INTEGRAL SEAT, RENEWABLE SOLID BWRE SCREED BONNET AND RE-PACKABLE EDGE DISC, RISING I PRESS.. 130/1. VNAEES ARE ACCEPTED AS M ECOAL SUBSTITUTION. B. GATE VALVES, 2-I/2 1.1 AIO LARGER: 5.005 125 GIST INN B7DY. 11 BEOWE SEATS AND SOLID E. DISC, RISING STEN, FLANGED ENDS, AN E -PACKABLE RUDER PRESS/E. C. SWING CHECK VALVES, 2 -IMII NO SMALLER: CLASS 150, CAST WORE BODY AEI CAP GOFOBJINO ro AN7/ B 52 WITH NORIZONTA SWING, Y -0ATIERN, EIEWMI.E BERM DISC, AND HAVIM THENED OR SOLDERED ENE. D. SWIM PECK VALVE, 2-1/2 INCH NO LARGER: CASs 125 CAST IRON BOY NO BOLTED GP, WITIZONfAL SWING, REN9PBLE BRONZE DISC, RAGED ENS NO CAPE BEING REFITTED WHILE THE VALVE REMAINS IN TE LAN. E. CIBINATION B.NCING NO SHIT -OFF VALVES: BELT. G SSETT CIRCUIT SETTER WITH LACKING SET POINT. A CIRCUIT SETTER BALANCE 'REEL COST E UNGLUED WITH 0 6 / WM. TACO OR IRISWLD ARE CONSIDERED AS EWE. 4. PIPING SPECIALTIES A. PESSBE/IDPERATUE TEST RUG (PETE'S PLUG) - 1/4 INCH 1PT FITTING TO RECEIVE EITHER A TEMPERATURE OR PREM. PEE, I/5 11421 0.0. FITTING MD CAPS SHILL BE BRASS WITH VALVE OGRE OF MOREL. RATED AT 400 PSIG, 0 10 200'F. B. SWIMS -'Y PATTERN STRAINERS, 125 PSIS. CAST HON BODY WITH PERFORATED 0T 5 STEEL SCREEN, TIRED FOR 2 INCHES NO MAUE01. R, FLAWED AWED FOR 2 :ACES MO LAMER. S.F. OPENING SIZE AT 0.00 I. FOR HEATING NO I/5 INN FOR CHILLED CR CONDENSER WATER. PROVIDE WITH MOM VALVE WITH HOSE END FITTING. C. TIERMO INDICATIR - BELL 6 ESSER MOB. • TRH • . 5. INSUATION WATER 08(119 INCLUDING 1906 OENSR WATER U SS HEATING SPECIFICALLY NOTED OTHERWISE). VALVES. FITTING, AHD ACG.S:DRIES SHALL BE INSIILATEO. FOR PIPE SIZES W TO 2 )NOES, INSULATE WITH 1 IRON THICK (N -0.23 • 75•F) FIBERGLASS INSULATION WITH AL SERVICE JICIET ND VAPOR War BARRIER. FOR P I K S 1.111/ 5 ICE JIQ2 INOESS AP �LA INSOLA C• T NL ET NO VAPIR B. C. BARRIER, INSULATION AT ALL H.. FIR PIPING 2 I/2 WOES AND LARGER SAL. BE NAM NO NOFCOPRSSIBE. ALA. INSULATION SAL HAVE A FLAW STEAD RATING OF NOT MORE TAN 25 NO A SI. DEVELOPED RATING CC HO NIGER THAT 50 TO COFORI WITH TIE REQUIREIENIS OF THE IFPA. D. PROVIDE ZESTON CR EQUAL INSULATION FITTINGS FOR ILL TEES, ELLS CR SPECIALTY FITTINGS. 5. GENERAL INSTALLATION A. INSTILL WATER WINS WITHOUT PITCH. USE ECCENTRIC REDUCING COWLITZ AT COMES IN S17E WITH THE TOP OF PIPES AT SALE ELEVATION. 8. B 1.5 TO WITS BELOW MAWS TO BE TN. FROM B01. OF MAINS AT A 45 DEGREE OGLE. PITCH DNA. TOTED WITS. SWEES TO WITS ARVE WINS TO BE THEN FROM TOP OF WINS AT A 45 DEOEE NEE PITIED '.IP,WiD MINDS WITS. Pl. NOT LESS TWA 1' ro 10 FEET. C. .1.1.1.1. DETAIL. DRAWINGS FOR APPLICABLE DETAILS. 0. REFRIGERANT PIPING: 1 NOT APPUOAffiE I. THIS CONTRACTOR SHALL FUWISH AND INSTILL A COPLETE REFRIGERANT PIPING SYSTEM ETTER THE INDOOR FAN WITS NO OUTDOOR FM WITS, IF APPLICABLE. PIPING A. REFRIGERANT PIPING SALL BE TYPE • L • MI) CRAW COPPER MUSTY BBB). TURING SHAW. E CLEO, CAPPED NO B. ALL FITTINGS NO JOINTS GALL BE YMUWIT COPPER OR CAST BRC17E (ANSI Bi5.22). NL OTPPFR ro COPPER JOINTS 9ULL BE T 1 B A COP WITH SRIOPoS ALLOY AND ALL D ETER JOHN15 SHALL BE OW ED RA IUS T WITH TYPE. -5 ALLOY. C. Atl ELBOS ARE ro BE Laic RADIUS 3. INSTALLATION A. SUCTION LINES SHALL HAVE ADEQUATE LIFT TRAPS NO/OR DOUBLE MOTION RISERS TO IEEE TIC ECHEIENTS OF FIELD CONDITIONS NO EQUIPMENT MVLFACTUEA'S EOMENDATIONS. B. OWE ALL JOINTS WITH SILFOS -5 STARTING AT THE INDOOR WIT NO WOKING TM. TE TIM= WIT. TE SETS ON TE OUTDOOR WIT SHALL E EDEN LAST. A NITRO:EN BLEED SHILL BE USED DURING ALL SODERIND AND ANY THE TIE STEM IS CET. ALL OPEN LINES SHALL BE GIPPED ND SEALED BEFORE LEAVING TIE SITE DURING CpSTRCTION. PRESSURE TEST KR LEANS WITH M INERT GAS AT TO 245 PSIG. REDO LEAKING JOINTS ND RETEST (MIL M. IS TIGNT. EVACUATE ECM SYSTEM ro 200 MICRONS OF MERRY. STRESS STEM WITH 25 PSI OF R-22 AND A )NAT GAS TO 245 - PSI APO RETEST SYS. WITH HALIDE LEM DETECT,. NI LEAKING JOINTS COST BE CO EETELY RESEALED UNTIL HO LEANS EXIST. TURN ON CRANK CASE .MIS 24 .RS PRIOR ro STARTING COPES= TO BE SOW ALL REFP.IGERME LIQUID IS MT a 1E CONFESSOR. PNG � TION 01 15 APPLIED, TE PIPING M6T BE IGERNR INSPECTED BY A REPRESENTATIVE OF THE LOCH. WVERIING MINORITY AS.ECESSFRY. imuLATE TNE REFRIGERANT ACTION LIES AND C9NDENSATE LINES ONLY WITH RUBATEX M AMER. 1 INCH THICK PIPE INSULATION WITH FLAW SPREAD RATING OF NOT UDR THAN 25 ND A SCONE DEVELOP. OF MT WE THAN 50 IN ACCORDANCE WITH INDUSTRY STNO 1 DO ND INSULATE Tic HOT GAS LIV IID) LNES OR AN? Y nu GAS BYPASS LIES, IF ) CARE 4. INSPECTION A. COIIRICT9R COST PREPARE AO Sour A Tsp.. pin. SCHEMATIC ro TE LOCAL WRIER FIELD REPRESENTATIVE FOR APPROVAL PRIOR TO BEGINNING INST.LATION.' )PDX COP 1)1600 ETI9T OF PIPING,. THIS LTOR MST CALL 0 LOCAL CARRIER INSPECTOR FOR FIELD INSPECTION a WOK INADEQUATE AFFOL.S P EXPENSE. IBY 9601 0 % REPRESFMATIVE MST BE CO ECTED AT ND 00I7ION/ CHARTS TO L.S.P. P. LABELS/PIPE MM. 1 NOT APPLICABLE 1 I. FURNISH NO INSTALL PIPE IDENTIFIGTIC, MAREE CI ALL PIPES INSTALLED DOER THIS GOWN.. RISERS GALL BE A MINIM/ OF 1 -1/2' X IDENTIFIED NI ' AND IDIFIED IN N.RDA TN TE BACIMEM NO LETTER CLCS UNSHED BY TE NERICAN NATIONAL SPHERE INSTITUTE (OBI). INNERS BOLL BE MANUFACTURED B Y CIMPION MERICA INC. MD-521 -7000, DR EQ M.. 2, PIPING STALL BE IENfIFIED AN FEL.: ONILLED WATER REIUW. WILLED WATER SUPPLY, OOOEWATE. HOT NEER RETIRE, HOT WATER SUPPLY, CONDENSER WATER RETURN. COOENSERR EATER SUPPLY, REFRIGERANT LIQUID, REFRIERME SUCTION. ND DIRECTIOYL ARROW. NL IDENTIFICATIONS MST BE VISIBLE AT =IRENE. Q. CUBS NO STEEL EWING FOR SPKRT I. THIS EXTRACTOR WILL FIPWISH NO INSTALL ALL NECESSARY ORBS NO STEEL FRAMING REQUIRED TO INSTALL ALL HVAC EMIRENT AN DESCRIED CO IMPLIED 01 THE DRAWINGS. CURBS BALL BE A MINIM/ OF 14' HIOi, OF TIE SEE RE F.TPER OF 11E E1UIRENT 5CPPORTED ULE55 NOTED OTIEMISE. INSULATE UNDER TE COMM SECTION TO PREVENT CMENSATION. NL CURBS NAT BE I TALLE SO OP a ORDS NE • DEAD • LEVEL. ALL PEIEI1 EXIST ATIONS OF EXISTING STRUM. SHALL BE DOE IN MORDAXE TO TE ME/LOWS TIMELINES AT THIS CAYIACTOR'S EXPENSE. THIS CNRM GR MT RECEIVE L.S.P. PROJECT &RAER'S WRITTEN APPROVAL BEFORE MT ADDITIONAL DWI TALES PLACE. R. TESTING. ADJUSTING, NO BALANCING I. TESTIND, ADJUSTING ND !MUNCIE OF ALL WOK SHALL BE MADE BY M'EFFEOENT CONTRACTOR TO IS A MEETLY LICENSED ASBCIATED AIR BANGING COUNCILL(E OR VATIC. ENVIE:MENTAL BALANCING M OT ANA. REPORTS W INS IEVIEED'BR AL'LEPiFD ML BALANCING VON COST E COPLETE ND DOE IN.0FENKE WITH THE 1051 RECENT STANDARDS a TEI0 ETY ND AS A RINIW SHILL 1143.110E II10016101101 AS MOM IN THE AIR RENEE REVIEW CHECKLIST IN PARAGRAPH 7 BELOW. PARENT a ILL COSTS FOR TESTING AND BALANCING SOIL E INCL.) IN TIE BID. 2. FINAL TESTIHO, ADJ.. AND NALNEB REPORT AIST BE COPLETE AND RM. OVER TO L.S.P.'S PROJECT ISOMER 1 PEEK PRIOR TO !CRO E'S!. DATE. 3. TE HIV. CON7RILTOR 9W.L E PRESENT FOR AIR BALANCE 1D VERIFY ACESSIBILITY TO 10.1. DEVICES, VERIFY ILL OPERATION SEQ C S MD INSTALL HEW FILTERS IN ILL WITS JUST PRIOR TO THE AIR BALANCE. TIE CCPLETE AIR BALANCE SELL THE PUCE WITH CUTS'. AIR DAMS IN MINI. POSITION, EXCEPT AS NOTED OTHERWISE. HVAC CONIRICTOR SHALL ALSO INSTALL A I. SET Of FILTERS OE DAY PRIOR TO IERCWWISINO. 4. BALANCING CONTACTOR MST CUNT. CARRIER CONTROL TECMICIAN 24 TAUS PRIOR TO AIR BALNE FOR COQOINATIW OF THE DIRECT DIGIT. O.RO. PANEL OPERATION CURING THE NUNCE. BENDING CONTR.. MAY E REQUIRED TO PERFON CERTAIN.N.LIC READINGS IN.DITION TO THE AIR BALANCE FOR CSJRATINO VAV BOXES. CALL COMER CONTROL TEPNICIAN TO VERIFY PROCEDURES PRIOR TO BITING PROJECT NO INC. ALL COSTS IN BID. 5. BALANCE AIR AO WATER SUOMI. TO WITHIN +55 SF THAT I11GTED ON THE DRAT.. ANY REWIRED CTWOFS IN SEAMS. BELTS OR PALEYS NEEDED TO ACHIEVE SPECIFIED F.1 RATES SHALL E PERMED BY 1TE INC DETRACTOR WITH PO ADDITIONAL CST TO L.S.P. INC. S. ALL CET. SWAMP MEL BE TESTED (INIEEa1® EQUI ENT 901E ET 510110 CO N 0 06 1 T&ON , S IT.. ffR, ETC,) AD OPERATIHO STAIUS ECPOED IN TW E}ORT. 7. ...pi.. THE BALANCE REPORT SOIL BE Sm.. THE. TE GJW_ CWNPALTOR TO L.S.P.'S PROJECT Al/lIACFR FORM W.. TIE GOER. CO TRA OR SHALL VERIFY TE COPLETUESS OF TE REPORTS PRIOR TO SWATTING TO L.S.P.. SEM Ct COPY OF FM/ APPROVED AIR BALANCE REPORT TO MEL GENERAL Il NIGER. B. THE BNANCIND coo.. SOIL Kw. ALL APPLICABLE TESTING AND BALANCING FIR.. REQUIRED FOR TE SYS. DSSIEFD ON THESE DRAWINGS. AL STIES CABLE ro E COPLETELY BALANCED AT TIE TIW OF ORIGINAL &LANCE LUST BE BALANCED IN FuNE AT ND ADDITIONAL EXPOSE TO L.S.P. TIE &UNCINI CONTRACTOR SHILL EOEC7( ANY ITEMS THAT L.S.P. DEEPS ECFSEARY AT ND ADDITIONAL COST TO L.S.P. S. CONTROL SESTET START-UP I. NNE =TESL STSTFFI STMTUA IS JVE ES[OSIBILITY OF CARRIER .D TO AL T1 W AID TE IL SYSTDI CONTRAC DOES NOT NEED TO .ION TINE FOR CONTROL MTEN STARTUP. END Of SECTION 15500 Store 0 DMelon: Mall Name: CIty. State: - Limited Store Planning - Alr Balance Contractor Oue1)10101tre Air Balance Contractor to remove this sheet and attach to complete alr balance report Yea No ❑ ❑ 1. Report prepared by NEBB or AAOC 11061169d contractor? ❑ ❑ 2. All vdtagae within 250 from ph0ss to phase a6 r6quir61 by unit nameplate 6pec10ca ❑ ❑ 3. All current within 1050 from phase to phone as required by unit n0m0p10)6 specifications? ❑ ❑ 4. All input and output alr tempeu withln 0000p)lbI, range for this unit for each m a d ralren e and stage? ❑ ❑ 5. Landlord wpplled media (alr 0r 60)69) te within 550 of design old media goo within 1 of design? 6. i rly diffusere, return l 9ss, duct trovee ❑ ❑ All and sw static (01)66601)66 or withln 10(ten ) percent of *161 (per latest reN6lon)? 7. le this project signed off by Issue of a control number ❑ ❑ from the Cartier National Response. Center at (809) 453- 4991 (she note /I)? Please acknowledge by noting control number. 00000 Note: 1) The Carrier National Response Center at (890) 453 -4991 must be contacted to caimrate now sensor readings before a control number will be Issued. Cartier Is the Issuing party and will )ewe the control number at their discretion. MAY 1 8 2001 6 Air Balance Contractors Mr Balance Contractor Signature Embossed Seal (required) •AN Balance Contractor to remove th,s thee) and attach to complete 01r balance report L J z z z J 0 u..1 0 I1) he CC a W a C W W co co > z a a� W W O) o ›- a- = o mf - � x�G3 le co d r F. I1 -TT 011120 SHEET MS.1 Q DE Z