Loading...
HomeMy WebLinkAboutPermit M01-067 - BOEING #9-101City of Tukwila Permit No: MO1 -067 Type: B -MECH Category: NRES Print Name:__ Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 41 MECHANICAL PERMIT Address: 9725 EAST MARGINAL WY S Location: Parcel #: 000340 -0018 Contractor License No: TENANT BOEING #9 -101 9725 EAST MARGINAL WY S, TUKWILA WA 98168 OWNER BOEING PO BOX 3707 - M/S 1F -09, SEATTLE WA 98124 CONTACT JOHN MURDOCH PO BOX 3999 M/C 89 -15, SEATTLE WA 98124 UMC Edition: 1997 Valuation: Total Permit Fee: Signature:. _ Date: Status: ISSUED Issued: 05/08/2001 Expires: 11/04/2001 Phone: Phone: 253- 773 -0444 ********************************************* * * * ** * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: RELOCATE TWO PAINT BOOTHS FROM THE #21 -1 BUILDING AND REINSTALL AND MODIFY INTO ONE IN THE #9 -101 BUILDING. * * * * * * * * * ** ************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** - g - 0/ enter Aut orized Signare Date ereby certify hat I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this b7 lding permit. (206) 431 -3670 40,000.00 65.06 Title: 62C,6> This permit shall become null and void if the work is not commenced within 180 days from the date of . issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. tY w. U O ; coo w . J =. 1- wO J. w o ' w ~ iil U O !- w W. LLO U= O 1- "' z .' DEPARTMENTS: Building Division 4t" Public Works ri Complete n Comments: TUES /THURS ROUTING: Please Route WRKOUIIDOC srri PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER M01 -067 Original Plan Submittal DATE: 4 -24 -01 PROJECT NAME: BOEING RELOCATE PAINT BOOTHS SITE ADDRESS: 9725 EAST MARGINAL WAY S SUITE NO: X Response to Incomplete Letter #_1 Response to Correction Letter # Revision # AFTER Permit Is Issued Fire Prevention Structural n Structural Review Required Planning Division Permit Coordinator • Incomplete n Not Applicable DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 4-26-2001 No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE 05 -24 -2001 A pproved n Approved with Conditions C Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: �;'1i?.1"z:3•F. ;t;;YS'<Pubtr� +' tlM. titV .le #*+'s.Yaan,m�.m.o..�.... CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions ri Not Approved (attach comments) REVIEWER'S INITIALS: DATE: PERMIT COORD COPY Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: MO 1-067 ® Response to Incomplete Letter # 1 0 Response to Correction Letter # 0 Revision # after Permit is Issued Project Name: BOEING #9 -101 Project Address: 9725 East Marginal Way S Contact Person: John Murdoc Phone Number Summary of Revision: PL 191 itmetitzo Sheet Number(s): "Cloud" or highlight all areas of revision including date visiin Received at the City of Tukwila Permit Center by: l ikEntered in Sierra on City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 04/10/01 .._:Y. +.:...,r: •LAU4i: "J �.'-.,.... n...... •i:l.l' n. ✓. ".: t.iis, �r rt::�: <II -:'.. �,.. r';',' April 10, 2001 John Murdoch PO Box 3999 M/C 89-15 Seattle, WA 98124 Dear Mr. Murdoch: Brenda Holt Permit Coordinator City of Tukwila File: Permit File No. M01-067 Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: Letter of Incomplete Application #1 Development Permit Application Number M01-067 Boeing #9-101 9725 East Marginal Way S This letter is to inform you that your permit application received at the City of Tukwila Permit Center on April 9, 2001, is determined to still be incomplete. Before your permit application can begin the plan review process the following items need to be addressed. Building Division: Ken Nelsen, Plans Examiner, at (206)431-3670, if you have any questions regarding the following: 1. Provide listing of new window to be installed in paint booth. The City requires that two (2) complete sets of revised plans be resubmitted with the appropriate revision block. If your revision does not require revised plans but requires additional reports or other documentation, please submit two (2) copies of each document. In order to better expedite your resubmittal a 'Revision Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206)431-3672. Sincerely, 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206-431-3665 ACTIVITY NUMBER M01-067 DATE: 4-24-01 PROJECT NAME: BOEING RELOCATE PAINT BOOTHS SITE ADDRESS: 9725 EAST MARGINAL WAY S SUITE NO Original Plan Submittal X Response to Incomplete Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: 1111KOUT 1.00C • (m) PLAN REVIEW/ROUTING SLIP n Structural Incomplete 1244 ( TUES/THURS ROUTING: APPROVALS OR CORRECTIONS: (ten days) Fire Prevention n Li Permit Coordinator I P i 11 Please Route Structural R1v Required REVIEWER'S INITIALS: da•ft, DATE: Planning Division DUE DATE: 4-26-2001 Not Applicable No further Revie Require DUE DATE 05-24-2001 Approved p Approve wit Conditions Not Approved (attach ommr ts) REVIEWER'S INITIALS: /1 DATE: ..■ CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions p Not Approved (attach comments) ri REVIEWER'S INITIALS: DATE: “.• PERMIT NO.: MIDI-U.57 MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 0 0 ❑ 00002 Pre - construction ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation /Indoor AQC ❑ 00610 Chimney Installation /All Types ❑ 00700 Framing ❑ 01080 Woodstove ❑ ` 01090 Smoke Detector Shut Off 01100 Rough -in Mechanical 01101 Mechanical Equipment/Controls 01102 Mechanical Pip /Duct Insul 01105 Underground Mech Rough -in 01115 Motor Inspection 1400 Fire Final 01800 Final Mechanical ❑ 04015 Special -Smoke Control System CONDITIONS .[7/ 0001 No changes to plans unless approved by Bldg J � Div ❑ 0014 Readily accessible access to roof mounted equipment 0016 Exposed insulation backing material 0019 All construction to be done in conformance w /approved plans ❑ 0002 Plumbing permits shall be obtained through King Co 0027 Validity of Permit 0003 Electrical permits obtained through L & 1 0036 Manufacturers installation instructions required on site "BTU maximum allowed per 1997 WA State Energy Code" 0041 Ventilation is required for all new rooms & spaces 0005 All permits, insp records & approved plans available ❑ "Fuel burning appliances ❑ "Appliances, which generate...." ❑ "Water heater shall be anchored...." 0 0 Additional Conditions: TENANT NAME: FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace /Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor - mounted Heater (qty) Appliance Vent (qty) Heating /Refrig /Cooling Unit /System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 cfin (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) Plan Reviewer: U" Date: Add'l Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'l Plan Review (hrs) Permit Tech: Date: DEPARTMENTS: Buil g'Division anted 4- n Public Works Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Th rs.) Complete Incomplete Il Comments: LM G WUOUIFAOC PERMIT COORD COP' PLAN REVIEW /ROUTING SLIP Original Plan Submittal NUMBER: M01 -067 DATE: 4 -09 -01 BOEING 9 -101 RLOCATE 2 PAINT BOOTH 21 -01 SITE ADDRESS: 9725 EAST MARGINAL WAY S SUITE NO: Response to Correction_. Letter # Response to Incomplete Letter # Revision # After Permit Is Issued Planning Division n Permit Coordinator lP(-6 tt 0mAad 4- /001 (Y� n lel DUE DATE: 4-10 -2001 Not Applicable El TUES /THURS ROUTING: Please Route n Structural Review Required L___i No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE 5 -8 -2001 Approved El Approved with Conditions C Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions n Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: PLAN REVIEW /ROUTING SLIP TIVITY N UMBER: M01 -067 DATE: 4 -09 -01 BOEING 9 -101 RLOCATE 2 PAINT BOOTH 21 -01 9725 EAST MARGINAL WAY S SUITE NO: Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works • TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: IPRRouTr.00C • n Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Structural Review Required APPROVALS OR CORRECTIONS: (ten days) Approved El Approved with Conditions n Fl n Planning Division Permit Coordinator n n DUE DATE: 4- 10-2001 Complete n Incomplete Not Applicable n Comments: ;$44l new wigiska 4 10e Ibtsfulied .tik ` ..}- look- 1 -1 No further Review equ'red n DATE: 1 CI DUE DATE 5- 8-2001 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions' 1 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: .e1.o-N�Nr e:vr:nt ..- :�eter:�';.rat7 °�x PLAN REVIEW /ROUTING SLIP TIVITY NUMBER: M01 -067 PROJECT NAME: BOEING 9 -101 RLOCATE 2 PAINT BOOTH 21 -01 E ADDRESS Original Plan Submittal DATE: 4 -09 -01 9725 EAST MARGINAL WAY S SUITE NO: Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works vnaourz,00c • WMI n ❑ Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) • n Planning Division Permit Coordinator n DUE DATE: 4- 10-2001 Complete n Incomplete Not Applicable ri Comments: TUES /THURS ROUTING: Please Route ri Structural Review Required ❑ No further Review Required C REVIEWER'S INITIALS: ' 4 DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE 5-8 -2001 Approved C Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: a .I J I DATE: L I - IX -C V CORRECTION DETERMINATION: DUE DATE Approved ri Approved with Conditions n Not Approved (attach comments) ri REVIEWER'S INITIALS: DATE: Project Name/Tenant: 1 + 1/t/ r BOONS ���•q OCa ' Value of Mecharyy 5Epyipment: • Site Address : q 7 t 41 f f , ,_, ,.1 ity Sta Z`j,i�: ,� • Tax Parcel Number: Property Owner: 77.1e �, N J n � , , � " iV CAM Phone: (ja) . 2 3. + 0 Street r s: Cit St te/Zi : O• tae 39 9 IA c 84•I5 , -; } Fax #: () ,, 7 R Contractor: .7 l 4 ,/ 06146. ety409,0y Phone: (263) 1 Street Alt: A A)( 9 No QG `('- 6477 ,,, - � C S ' tate/4ip: , . Fax #: (Z ) ?9L12 Contact Person: y 6 AA r / L t,,,f -7 .15���� e..0 Phone: ( -3 ) - •8L Street Address : Q� `� .1 , ►i2 M k ) g i y $tau pe , C Fax #: ( 7 1 3 2, 'BUILDING t, ' R .AUTHOR! ED AGENT :.. . to , II.:. 1 ,Tnl I . Signature: ,r>�' �,—, -. -7146 .% j • 1� e t Y Dater t� i Print name:' Jury 5 Mule �^ , " q Fax #: ( T ) - f3a Phone: (3) 69/1 Address?" 0. 41 15" City /„•a A jot i ail f /vv./r 2m9 »elkorli CITY OF T *KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 STAFF USE ONLY ql!l °CI; 'Pictj heti: Permit Nutnper. Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. : %: PERMITI'REVIEW AND APPROVAL'REQUESTED:'(TO BE FILLED OUT' BY APPLICANT) Description of work to be done (please be specific): figt0Carg TWO 119/p ' eoevri F' 7H.9 Za-1o/ 8L 6 ij AON 4 4 wo® o /N rtie 61-101 &, Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: di eV j ib Date application expires: io ow S 01 Application taken by: (initials) c 11/2/99 mach permitdoc ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 ' H.V.A,C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water . heaters or vents being installed or replaced. RESIDENTIAL Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat loss. calculations or Form H -6. Equipment specifications. Change - out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace ,Narrative With,specification of equipment and chimney type.• _Ifiusing existing chimney,. provide a letter b'y a certified chimney sweep stating that the chimney is in safe Condition: ' 11/2/99 nasc►unf.doc NOTE: Water heaters and vents are included in'the Uniform Mechanical Code = "please include anyWater heaters or vents being installed or replaced. • { . • ST` Address: 9725 EAST MARGINAL WY Suite: Tenant :. BOEING #'9 -101 - Type: B -MECH ;Parcel, #: 000340-0018 CITY OF TUKWILA Permit No: M01 -067 Status: ISSUED Applied 04/09/2001 Issued: 05/08/2001 °It•k**** *6 it kk• k k• k• k' kk: 4'• k*** k' k*• k'. 4*• k' 6*****• kk: ik****• kk* k k' k' k*• k *k*kkkk'kk•kk** *kk'k *kk'k' ;Permit Conditions: 1. No changes will . be made to the plans unless approved by the Engineer and the Tukwi 1a'Bui lding Division. All permits, :inspection records; and approved d plans shall be available at the job site prior to the start of any con- struction. These documents, are to be ,maintained: and avail- able until fin 41'inspection'. approval : i s granted. All, construct1on to be done in conformance with approved plans and Tea,uirer)ents of the Uniform Building Code (1997 Edition a s arnend'ed, Uniform Mechanical Code (1997, ,Edition), Val i d 1 ty Permit The issuance of a permit or approval o; c lans.;, speufticat,ions ,._ and. computations shall not be .con str ued to be a :permit 16r.' or .en 'approval of . anv violation i'. city of %the; Drov i si ons of the : bu i l d i no code or of any other ord in n,ce of the .1 ur i sdi eti,cin. No permit presum.in'gv to ive authoritv,to violate, or - cancel the provisions of this code,,shal 1 be -val id. Manu acturer s'insta 1lat1on instructions required on site for the bu1lding inspectors. review. * *'kFIRE ,; DEPARTMENT CONDITIONS* *'k The,a'ttached set of plans - have =been' r-eviewed by The :Fire Pr event i on' Bureau and are .acceptable with , ,the, fo l l owi rig concerns.:-" An approved automatic fire sprinkler extinguishing 'system- is. repuired:,.for this project. (Citd:.Ordinance #1901) All neW%cprinkier and all rr►odificat: ions to ex:istinri' sprinkler• sySt,eMs shall have fire department review and approval ' of drawing prior to irnsta ilation or 'modification; New pri n'k l er ; systems ' and a l l m o d i f i c a t i o n s to sprinkler systems invc+lving mor.e than 5l'► heads , shall have the written approval of the W:,;S R:B ,. Factory Mutual,, Industrial .'Rl sk. Insurers. Yen►per or any:.: other , :rep re sentative designated and /or..recorghi zed- the City-of Tukwi-la,` ;.prior° to submittal to ;the Tc`i,kwi.la Fire "Prevention ' "Bureau. , No sprinkler work shall ccnumence without approved drawings. (City Ordinance #1901) All nN ler system :plans. calculations and the contractors Materials; and Test Certificates submitted to. the Tukwila Fire Prevention Bureau ,must be stamped with the appropriate level of competency. seal. (WAC 212 -80) All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler s:;+,( stems shall be electrically supervi,ed. (City Ordinance #1901) Provide a minimum 4A 40BC extinguisher within 30' of your spray booth. (UFC standard 10 -1) Portable fire extinguishers shall be securely installed on e. or in` the .bracket sUpPlied: =placed in cabihets r <;' wall . 're•cesSes The hanger, or br.acl et sha 1 1 be securely and properly 'an:chored to the' mOun "tins` surface in acco'rdence wi th the ; manufac:turer',s`•in , tructions. The: extinguisher .h "il >:be ° inst,alled so hat top '.of the extinguisher not mo"r4e than 5 feet Bove the floor and the c i earance -. etween the : bottom of ' •the ..extinguisher and the floor sha l .i not: be{less: than` 4 inches Clear ,access to: f ire 'extirrguishers is required at all They,'may not be hidden 'or. `obstt:ucted. (NFPA 1D 1 6 5 Fi.r;e. e:x in�gui: herti require • monthly -.and yearly inspections. They, must .h;ave a tag or securely. attached that . i rid icates the Month and .year that. the , inspection was performed "and; shall identify the company or : persona performing, the service:," ` (NFPA;10,: 43, 4 -4 and 4 =4,3) Everiv year=s, dry chemical `and ha ion tvpe - east i nau irsher s shall be emptied:: and subjected. to the a ppli ca bl e recharge procedures (NFPA 10, 4 -4. 1 ) If the required monthly ..and yearly inspections of : the fire extinguisher (s) are not accomplished ;Or,, the - inspection tag isnot te. a reputable fire extinguisher. service company wi l l he;, required to + ondu6t- these required red'. surveys. (NFPA l0,:'.4 31`.4 -43 A notice of construction permit musts be 'obtain'ed from t Puget 'Sound Air Po'l'lut.ion. Control "'Agency :prior, to the installation of .the spray booth., :The permit .:'shall -b posted at the ?°ubs,i to ' Any 'overlooked "hazardous condition and /or violation. of the adopted Fire or Building Codes does, not �.i mp ly. - approval: of x, uch condition• or viol'ati THESE PLANS : WERE REVIEWED BY " INSPECTOR 511. IF YOU HAVE ANY QUESTIONS, PLEASE CALL THE TUKWILA . FIRE PREVENTION BUREAU AT (24,6)575 -4407. An electrical ;permit from WA State Labor and Industries required for all electrical work. class I`, Division I and II electrical locations shall be accordance with U.F.C. Table 7901.4-A. Minimum air velocity shall not be less than 100 lineal per minute. 2 The spraying :equipment shall be interlocked with the ventilation equipment. I hereby certify that I have read these condi tions and wi11 comply with .them as outlined. All provisions of law and ordinances governing this work will be compl ied with, whether specified herein or not. a :'ranting of ; this permit does not presume to .give authority to ol ate or cancel the rovisions of any other worn or. local laws .gulating cstr tt or theperformance of War :: ' ' Gate: . ***k .t* : k * ***k: * k *..A,k•k * * * A•A =k ...k ., .4 t * t. Akk.k�k**k.k•k,kv4 **** T ;UKWtLA ; ,WA ` � IitANfileii : 1 ' . • c ** *A*frA *k *:*A ' lock*** wit *it IrA *k * *..*** k k.* ka *:kk.* * * It *•*k* * ** * :of k* * * * *A • TR .i�u'mber : 0 5 . 8 01095 A .n 1.1t,,, P "p vrnei 1, M etl7 a il:: GH : idat- ti t i an.» B 0E I N G Irii :.:;J'I 4:tr1ni No':; M91 067 :::'.: : U MECH • ri•EC'IHIA!ni PER ?In: ar•ce:l Na opo3 '003.x? ,d"drcs ,9743,EAST, MARtiIN L. Ni.. S Totel Fees: ..65:06. • ?ay00nt °: GS' „'O ti Total `ALL_ Pints; } 65 .' : Iicl'arice „. 0). k'ar * **`. -h * *** *A**A *k*'k l*** kA***** A k..• k* **** A* A • " *kiqr*;ikA ** *kk:k..kk f�.ccatt;rit; Code :Det;cr' Ar7o�trit. �.q /34 i . . .CHECY WQNREB : 1341 O00/ 2 1.U..q i E CHANICAL:. '..i`!ONR : 5 -.45 'Project: - - 73LL°l #' f / Ty o Inspection: ' 106 � . AddressJ 725 , M r mrt./ id $ D e ,. 0/ pecial instructions /� 1 /f✓ C. � I��j / � ee ; f fi : 3,Ary Da e w me /t1 IV / p .m. Req ter Ph 2 ne tp- 155 -1D INSPECTION "RECO Retain a copy with E. it INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 206)431 -3670 Approved per applicable codes. 0 Corrections required prior to approval. , g , pkAMENTS: Date: 3 / r / f $4 7.00 REINSPECTIO FLE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Prol Type of Ins ion: �� • 1 ' Address:: . Date called: • 13 Q N .Fire � r ' ,,, J qt, lft 0 - caLtt. -DI, • ,I Qr4i o I - itaaof D ate want . '1,1Q � 1.171.7 ' Reques Ph e POO 1.06)... toff'? 'INSPECTION REC Retain a copy with permit INSPECTION NO. • • CITY. (* TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 •'pro e MMENTS: PERMIT NO. (206)431 - t 67 r ap . lica le 6'6es. Corrections required prior to approval. C — /7,, r ' G./ ? * AZWe 4 _4 s, Gele eela 449 — /�- $47.00 REINSPEd$ION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: t Receipt No: Date: z : w : J U; oo N 0 : CO w ; W o . y D: 0 6U W U o _. = W 12 10 O �. z Sprinklers: Fire Alarm: Hood & Duct: Ha lon: Monitor: Pre-Fire: Permits: Approved without correction notice. Approved with correction notice issued kkkis 0.1 , -Avo, Authorized Signature _ . FINATJAPP.FRK:'! .0....•••• • City of Tukwila Fire Department 1 2 ) TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Rev. 2/19/98 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 Permit N Thomas R Keefe, Fire Chief • . • Steven M. Mullet, Mayor - 3/ - - / • Date T.F.D. Form F.P. 85 „ , , • .., ‘,„ . ...y.,: • . • • • • 2 1_ re 11 00 Hi 0 cu. co u _ ill 0 • g u. 52 a I- 0 • Z ut . a 0 .0 a 0 1- IU LU u. 6. . z co . 0 1— z ' City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Fire Department Review Control #M01 -067 (511) Dear Sir: April 19, 2001 Re: Boeing Company Building #9 -101 - 9725 East Marginal Way South Steven M. Mullet, Mayor The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. An approved automatic fire sprinkler extinguishing system is required for this project. (City Ordinance #1901) All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler . work shall commence without approved drawings. (City Ordinance #1901) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. (City Ordinance #1901) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 City of Tukwila Fire Department Page number 2 Steven M. Mullet, Mayor Thomas. P Keefe, Fire Chief 2. Provide a minimum 4A 40BC extinguisher within 30' of your spray booth. (UFC standard 10 -1) Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly • inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) A notice of construction permit must be obtained from the Puget Sound Air Pollution Control Agency prior to the installation of the spray booth. The permit shall be posted at the jobsite. 3. An electrical permit from Wa. State Labor & Industries is required for all electrical work. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 City of Tukwila Fire Department Page number 3 7. Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinances #1900 and #1901) Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, cc: TFD file ncd The Tukwila Fire Prevention Bureau Steven M. Mullet, Mayor Thomas P. Keefe, Fire Chief 4. Class I, Division I and II electrical locations shall be in accordance with Uniform Fire Code table 7901.4-A. 5. Minimum air velocity shall not be less than 100 lineal feet per minute. G. The spraying equipment shall be inter-locked with the ventilation equipment. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575.4404 • Fax: 206-575-4439 .FROM :CONSTRUCTION MGMT HENDERSON ENTERPRISES, INC. Industrial Ventilation I Li81U11. tio�. 4/2312001 Boeing Defense and Space Group Construction Mrtaga rent Seattle, WA Dear Carson: Mr. Carson Romer 206-544-2668 206- 655 -4821 FAX Modify two 10' x 10' Blacker Brothers Paint Booths. Moving from Bldg 21 -01 to 9-1012 (MDL) Pet your request all Bleaker Brothers Paint Spray Booths are built according to the specifications below: 'Uniform Fire Cede, Article 45 (UPC) *National Fire Protection Association, Pamphlet 33 (NFPA) 'National Electrical Code (NEC) Enclosed herewith also is an c cerpt from the Bleaker Brothers catalog stating the same. Please contact us for any other iniorrnatim necessary. • H. Hem President 10 206 695 4621 2001 -24 07:38 11372 P.01 /03 15206 N. E. 1101h•PI. Redmond, M98052 (425) 867 -2400 Fax (425) 882 -1777 GEN. CONt. tit I4 ENlW..EIQWM1 INCOMPLETE LTR# RECEIVED CITY OF TUKWILA APR 2 4 2001 PERMIT CENTER 41, (a. 067 Pir S. • FROM :CONSTRUCTION MGMT 411111113. 205 555 4021 -.mow HENDERSON ENTERPRISES, INC. 15238 A E 11VIn 1 R sarrond, WA 98052 °LUKER BROS, 2001 ^4-24 VESIT SPECIALISTS 'Ewes, Service Cal L. CiENDEEMENN Phole (4251 887•74C0 Fal 1125I 832.1777 %It Industrial & Automotive 07 r 39 H372 P.02/03 Mann acturing Quality For 50 Years Clean I • It :• 7,7 • • :• oql.trf,,,t:koAmt.tfw.4:mpmct'Pr..tr FROM :CONSTRUCTION MGMT Features • All Floor Filter Point Spray Booths adhere to the Uniform Fire Code and the National Eleotrioal Code, Always check local fire and •leetrlcal codes for special condition. that mey prevail In your area. • Open -type (O.T.) Fluorescent Light Fixtures as listed are U,L- and C -U.L. approved, 4' long, 4- tubes. • Vapor-Tight (V.T.) Fluoresoent Fixtures se listed are U.L. and C- U.L. approved, 4' -long, 4 tubes, adhering to Hazardous Area Clem 1, Division 2 from the National Electrical Code. • All Light Fixtures are placed on the outside of 1/4" Clear Tempered Glass, gesketed end locked in place In the working depth of the Booth. • Fan Motors are 3- phase, 208/23D/460 volt, 80 Hz. • Light Fixtures are 120 volt. • Solenoid Valve is single phase. Voltage must be stated (1101820 etc.). • Fan Cutlet: top is standard. Back or side outlet can be supplied but position must be requested. • H.V. after model number, signifies higher Face Velocity for that model. All other models that have no alternate H.V, units can Increase their Face Velocity at a minimum expense by increasing listed horsepower ard pulley diameter, • Panels are skidded and banded P p cii apltn•Trp• Fl.roltsa•nl tljM;np its eoolhowhh 10' Nv, , Depth and ;miff 6 EMAIL: 611.ee for forklift handling, . • Fans, motors, filters, etc., ere packaged but loose. • Shipment by Public Carrier nes special requirements. Contact Factory or Dealer. Additional Features Available • Conveyor openings • Explosion -proof motors • Working depth extensions • Special width or height requirements • Special lighting arrangements • Contact factory or dealer for price adjustment. Construction Features • 18 -gauge galvanized steel panels. • Bolt construction. Inside of booth is smooth. • Filter cells are 20" X 2D" X 3 ". • Light windows conteln 1/4" clear tempered glass. • Fans are belt driven, with enclosed belt guards. • Blades are rigid -type, spark - resistant and dielectric. • Spray booth panels rest on heavy auty 14 gauge, galvanized floor angles. • Face velocity exceeds code requirement of 100 F. P. M. • gee specifications for face velocity of Individual booths. Typtel V po tr ruurtment lighting la 90nIM *It W:rntrp Depth at '•a• then I0' NOTES Lighting quantity is very subjective. Adding or deducting the quantities of light fixtures can easily be made to our booth arrangernente without losing the financial advantage of purchasing a packaged booth. Floor fitter booths exceeds U.F.C. requirement of 100 feet per minute lace velocity by at least 20%. Booth dimensions and price are subject to change without notice. BOOTH PACKAGE 1.10,1 I .I.0 �li.I.lun. ,.1 J n i:n I•. I •.1 .l I I. . I ..I u FROM :CONSTRUCTION MGMT HENDERSON ENTERPRISES, INC. Industrial Ventilation 4/23/2001 Boeing Uefeaae and Space Group Construction Menagtsntmt Seattle, WA 206 665 4621 Dear Carson: Aim.: Mr. Carson Hornor 206 -544 -2668 206- 655 -4821 FAX Modify two 10' x 10' Blakey Brothers Paint Booths. Moving from Bldg 21 -01 to 9 -101.2 (MDL) 2001'' -24 07:36 4372 P.01/03 15208 N. E. 110111'PI. Redmond, WA98052 (425) 887 -2400 Fax (425) 882 -1777 GEN.CONW IIC.PI€N11EEICriers Per your request all Bleeker Brothers Paint Spray Booth are built according to the specifications below: 'Uniform Fire Code, Article 45 (UVC) *National Fire Protection Association Pamphlet 33 (NFPA) 'National Electrical Code (NEC) Enclosed herewith also is an excerpt front the Blecker Brothers catalog stating tbu same. Please contact us for any other iniormgtim necessary. It Hee President don p 0 INCOMPLETE MAy 2 " LTR# -�— TING ° FILE COPY RECEIVED CITY OF T. •■• APR 2 4 1001 PERMIT CENi mot- 067 IFF FROM CONSTRUCTION MGMT 206 SGS 4921 Manu Mitring Quality For 50 Years Clean Competitive 4 LIJ HENDERSON ENTERPRISES INC. 1527E1N E 110th PI. RearnOnd, WA G05.2 pl aLF_Exin BROS. l J 4 2001 -24 InpuSTRIAL VENTILATION 3PECIALISTS inaletietion. Service C.r.it eiFhoEEtceeNN Phone (os) 587.74C0 Fat (425) 882.1777 ndustrial & Automotive "Wit.liV112; ,t Or: 39 14372 P.02/03 I .•••••••■•• 1. '-" •717 • • .^ r A 4;irt";•■: I ' , • FROM :CONSTRUCTION MGMT Features • All Floor Filter Paint Spray . Booths adhere to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special condition. that may prevail In your area. i• Open -Type (O.T.) Fluoreaoent Light Fixtures as listed are U.L.. and C -U.L. approved, 4' long, 4 - tubas. • Vapor-Tight (V.T.) Fluoresoent Fixtures as listed are U.L. and C- U.L. approved, 4' -long, 4 tubes, adhering to Hazardous Area Class 1, Division 2 from the National Electrical Code. • All Light Fixtures are placed on the outside of 1/4" Clear Tempered Glass, gasketed end locked in place In the working depth of the Booth. • Fan Motors are 3- phase, 208/230/480 volt, 80 Hz. • Light Fixtures are 120 volt. • Solenoid Valve is single phase. Voltage must be stated (110/220 etc.). • Fan Outlet: top is standard. Back or side outlet can be supplied but position must be requested. • H.V. after model number, signifies higher Face Velocity for that model. All other models that have no alternate H.V, units can increase their Face Velocity at a minimum expen8e by increasing listed horsepower end pulley diameter, • Panels are skidded and banded 1'pI4I apn•Trp• Fluarasa•nt Ugfnlnq 1a Boar,' wIlh 10'tWrl.lry Dept►, end rM ? 206 SSS 4821 for forklift handling. . • Fans, motors, filters, etc., are packaged but loose. • Shipment by Public Carrier nes special requirements. Contact Factory or Dealer. Additional Festuree Available • Conveyor openings • Explosion - proof motors • Working depth extensions • Special width or height requirements • Special lighting arrangements • Contact factory or dealer for price adjustment. Construction Features • 18 -gauge galvanized steel panels. • Bolt construction. Inside of booth is smooth. • Filter cells are 20" X 2D" X 3 ". • Light windows conta;n 1/4" clear tempered glass. • Fans are belt driven, with enclosed belt guards. • Blades are rigld-lype, spark - resistant and dl- electric. • Spray booth panels rest on heavy duty 14 gauge, galvanized hoar angles. • Face velocity exceeds code requirement of 100 F P. M. • 5es specifications for face velocity of Individual booths. 20Q r4 -24 07:39 'Nue, V•por' Fluum•.e,n L'yhtin• for Bonita Mlt6 W:rnlnp Depth of Ism than 10' NOTES Lighting quantity is very subjective. Adding or deducting the quantities of Tight fixiuree can easily be made to our booth arrangements without losing the financial advantage of purchasing a packaged booln. Floor filter booths exceeds U.F.C. requirement of 1D0 feat per minute lace velocity by at least 20%. Booth dimensions and price are subject to change without notice. BOOTH PACKAGE lilial.icJc -c�.= . .u1 ': IdI•.rvr 7 :01:,,ltt 111101: 1. II I 1 .r■ It . - 111 .ly I l l:.fr t, . u. nr. st 1100111 1..0 (-I. •r tt372 P.03/03 0) 1 I OTICE. IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT March 27, 2001 9- 4BC8 -TPR -011 D Tukwila Building Division 6300 SouthCenter Blvd. Tukwila WA 98188 Attention: Ken Nelson, Plans Examiner Subject: cc: Mary Jo Donnelly Carson Homer Carl Hall John Murdoch The Boeing Company P.O. Box 3707 Seattle, WA 98124-2207 Building 9 -101 MDL Lab Relocation A limited amount of hazardous materials will be stored in the 9 -101 building. These quantities will be under the exempt amounts of hazardous materials per Table 3 -D of the Uniform Fire Code.' These materials will be stored in closed containers within appropriate cabinets. Boeing A &M uses both a hazardous material management plan and a "Just -in- Time" program for the inventory management of hazardous materials, which dramatically reduces the quantities present in the manufacturing environment such as the 9 -101. Any quantities of materials in excess of the exempt amount will be stored in the 9 -04 building (the central hazardous material storage facility for the site). Please direct any questions to the undersigned. Thomas Rauen Environmental Engineering Safety, Health and Environmental Affairs Boeing Military Aircraft and Missiles System Group 206- 544 -0243 NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. File: 067 QTY DESIG. DESCRIPTION PART NUMBER . MANUFACTURER 1 ENCLOSURE A- 60SA3810LP HOFFMAN 1 PAN A -60P36 HOFFMAN 2 VENT KITS A -EXGR6 HOFFMAN 1 DISC 1494V -DR633 ALLEN BRADLEY 1 HANDLE (DOOR LATCH) 1494V -L1 1494V -L2 ALLEN BRADLEY • ALLEN BRADLEY 3 FUSES FRSR20 BUSS 1 POWER BLOCK 1492- P03141 ALLEN BRADLEY 1 VFD 1336- FBRF100AAEN ALLEN BRADLEY 1 KEY PAD 1201 -HCS2 ALLEN BRADLEY 1 CABLE 1202 -C30 ALLEN - BRADLEY 1 PRESS XMITER 607 -3 DWYER 1 , CONTROLLER 086050 -0 DWYER 1 PILOT TUBE 160 -18 DWYER 1 . DUCT MOUNT FLANGE A -159 DWYER 1 P/S PS5RD24 IDEC 1 SEL. SWITCH 800T H2A ALLEN BRADLEY 1 IND. LIGHT RED 800T P1 6R ALLEN BRADLEY 1 IND. LIGHT AMBER 800P16A ALLEN BRADLEY 1 CPT 9070TF500D1 SQUARE D 2 FUSES FNQR3 BUSS 2 CONTROL RELAYS 700HA32A1 -4 ALLEN BRADLEY 1 STACK LIGHT 855- A L1E-Al VIM D Ley 1 DUAL ALARM UNIT /620 67 API ■ 7 7 7 7 7 7 NO I wLNUAL AUTO I AIR PLOV CONTROLLER RED AMB GRN I Lo r geour mt START ( STOP I 0 0 3:k ALARM 0 _PAINT SOIL. SHUTDOWN - FILTER YARNING -NORMAL AIR NAILS UP CONTROLS WYE MUST Ott P4 .A M N:ooL wad e4mo• 7.5 HP 1336VFI; SPACE FOR FUTURE DEHUMIDIFIER CONTR ❑LS MOO* I . I . � � _ 11 1 . I - L I I : j ' I I � I .� I �__�.�.�. [11 - 1 .. I! 0 INCH CHINA TERMINALS DSI F U 1 F U 2 F U 3 P/B CPT FU4 FU5 FU6 DUAL ALARM UNIT hMITR P/S I RELAYS N D 71 6 9t VI. £G ° � ! � ! I!!!! �!! lIIIIIlIILIIII�!! Illl� lI , ILLLIIIIII111lIl . 1 IIILII�l IIIJ LLIIILI�I, ILI�IIII, LI), �ILI�� _►L).LIal�lllllllll�)IIIII MATERIAL LIST ri %i T1.0 WALL: NONE �• i ONI Or. 1 � l � i � i � j :( � l � l _ � . I • r unes HENDERSON ENT. BOEING CO. ao nte 30580300 00 NOT SCALE TOL UNLESS NOTED BAC ELECTRICAL PACKAGING CO. INC. 12414 HIGHWAY 99 SOUTH /16 EVEREIT, WASHINGTON 98204 O.G. NO. PAINT 800TH 12 EXHAUST FAN CONTROLS 001 1- 3058 -D101 I 3 .xx I .05 .xxx .020 ONE: 11 -9 -00 J. VENT HEAT nl COOL LI —� 0 0 83 START o 0 STOP _..t_ 1 C 0 4 FLAME ON MAXITROL TEMP SEL. TD114 M1 O M2 0 . TO BESSAM -AIRE UNIT 10 11FUe TOVDF S+ SPEED CONTROL 4 20M GFH AGC1 IIFU7II AGC1 5 GFH S— (o +24 I O PSI 24V POWER SUPPLY AIR VELOCITY SENSOR TRANSMITTER ® CONT, ,_LEF r\ o 14 20 . 1 0 15 3 0 RELAY 0 UTpUT -----0 0-1 GFI 0 GFN -24 COM GFN N 10 0.INCH CHINA 6 st. . I ( iiii .11:hiil.liii i 111.11 ihiiili ii.Ij.ii 11111, IJil 11111 ii,[i[i ijliiil1.a1t a 11111ari .,i i GFH AGC1 * - J1FU6II 6 01 40 ALARM RESET TD1 o— OPERAT TD2 1 T01 HLR TD2 HLR 11 DUAL ALARM UNIT 38 FILTER WARNING 45 W 46 1 47 PAINT SOL SHUTDOWN 48 HLR 49 1—€ 50 40 5 o 8 aio_. 30 7 0 1b9 0 -1ov FROM S INPUT VFO T01 31 T 33 TD2 34 HLR 35 EXHAUST 36 0.42 w • e 37 WLR 11 0 40 41 0 - HLR N a HENDERSON ENT. 80EWG Co. 00 NOT WALE DI Ms 30500300 SOAR NM Om •n R0O vow Oft TOM TOL MEW RDIED .>a � .O .>oa . OZ0 .rit, 11 -•-00 SOC. la 00 - 3058 -0301 WARNING TIMER SHUT DOWN TIMER NORMAL — -O WARNING N — — --e SHUT DOWN • 480V 30 60HZ 10 FUM5 — 11 Fu6 10 30A DISCONNECT 4 0- FNQR 4 DAMPER OUTLET - � 1' MAN. jAUTO 0 0 480V 120V 83 F CPT 500VA AJT20 1 ®1 I ®1 I ®I CSR • N 4 -20MA FROM CONTROLLER N 24 5l tL £l Zl 111111111111111111111111'1111111111111111 UNE REACTOR Al A2 81 d wyvvo 82 HIM. MOOULE S + CSR 1 111 f L1 112 113 1 I riTITTI-riT i 11111I 1,I.,i,,� �;,fill I 0 INCH CHINA E L2 .50 T1 E T2 E 1336 ((�� AC DRIVE ?3 L= T82 -- 1 I 10- CR3 CR3 T CR2 I 0 -10V OUTPUT 11 13 14 12 C FILTER CLOGGED 0 -10v COM 0 -10V + 111111111111 ��(III111IIljlf`I,�1 S S T1 0 T2 T3 TO DUAL ALARM UNIT �.�. I'l l ,1 1 1 L1111.IIIII111111111111I 111 1iiililIIIl 1 1 1 111111 11 11. 111 1 111 11111 111111111111111111111111111 GND -% AC MOTOR o t t J 7.5HP EXHAUST FAN HENDERSON ENT. DO NOT SCALE coo flL 30580300 sou: NONE old tr: ROB NOM lit TOM BOEING CO. TOL. UNLESS NOTED .X .05 .XXX 1 .020 oATC: 11 -9 -00 • OATE: ELM ELECTRICAL PACKAGING CO. INC. 1241 HIGHWAY 99 SOUTH 116 EVERETT, WASHINGTON 98204 PAINT BOOTH #2 EXHAUST FAN CONTROLS O . " 0011-3058—D302 7 J 7 7 7 HM NODULE I NIMKIAL AUTOI AIR FLOW CONTROLLER I START I STOP 0 0 ANN RESET 0 RED AMB GRN PAINT SOL. SHUTDOWN - FILTER WARNING - NORMAL f ol EXHAUST ON r�T 000. IEAT I axor 7.5 HP 1336VFri SPACE FOR FUTURE DEHUMIDIFIER CONTROLS I P/B DUAL ALARM UNIT I DSI F U 1 F U 2 F U 3 hMITR RELAYS I i .. . � �. � lil � l 1I1I1 a � l �. l .� l . l . l . il �. I �. L � 0 INCH CHINA 5 l' b L E L Zl ,�. 6 8 � E Z l� Illlillllllllllllillllif III II .'- � 1 111111111111111. 11111. I1LIL11111111111111 11111111111LIIIIIII I1.II.III,1�1► 11111LI1-11R111111. 11111111Ih111l►d►1111111lI FU4 FU5 FU6 CPT N D MATERIAL LIST QTY 1. 1 2 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 DESIG. DESCRIPTION ENCLOSURE PAN VENT KITS DISC HANDLE (DOOR LATCH) FUSES POWER BLOCK VFD KEY PAD CABLE PRESS XMITER CONTROLLER PILOT TUBE DUCT MOUNT FLANGE P/S SEL. SWITCH IND. LIGHT RED IND. LIGHT AMBER CPT FUSES CONTROL RELAYS PART NUMBER A- 60SA3810LP A -60P36 A -EXGR6 1494V -DR633 1494V -L1 1494V -L2 FRSR20 1492- PD3141 1336- FBRF100AAEN 1201 -HCS2 1202 - C30 607 -3 086050 -0 160 -18 A -159 PS5RD24 800T H2A 800T P16R 800P16A 9070TF50001 FNQR3 700HA32A1 -4 85S- Iozo MANUFACTURER HOFFMAN HOFFMAN HOFFMAN ALLEN BRADLEY ALLEN BRADLEY ALLEN BRADLEY BUSS ALLEN BRADLEY ALLEN BRADLEY ALLEN BRADLEY ALLEN - BRADLEY DWYER DWYER DWYER DWYER IDEC ALLEN BRADLEY ALLEN BRADLEY ALLEN BRADLEY SQUARE D BUSS ALLEN BRADLEY STACK LIGHT DUAL ALARM UNIT ALLEm BRADLEY APi CLISTOHEN C FO FILE 30560300 SCAM NONE w M Or 606 Dose Ar: TOM HENDERSON ENT. BOEING CO. 00 NOT SCALE TOL. UNLESS NOTED .xX I .05 .xxx .020 tun: 11 -9 -00 OATS: ELM ELECTRICAL PACKAGING CO. INC. 12414 HIGHWAY 99 SOUTH 116 EVERETT, WASHINGTON 98204 NHL PAINT BOOTH /1 EXHAUST FAN CONTROLS ONG. N0. 0011-3058—D100 - 480V 30 60HZ L1 L2 L3 1 10 30A DISCONNECT F 4 10 FLMS CPT -- f FU6 500VA 4 BMC 0- -- MAN.L 0 0 480V 120V 83 AJT20 I ®I FNOR• 4 CSR N T2 I 4 -20MA FROM CONTROLLER N 24 LINE REACTOR Al A2 81 6,v- 82 Cl C2 HIM. MODULE 0 INCH CHINA CSR 1 S1 Pl. El 11111► 11111111111' 1111111� iliiiilil ilii�i�1�1i11 .i�1;►i L11 L12 L13 Li L3 1336 AC DRIVE CR3 CR3 T C R4 CR4 T T82 -I I 10 CR2 ALARM 0 -10V OUTPUT T1 1.=.. T2 E T3 L:; 12 11 13 14 T1 O T2 T3 0 -10V + FILTER CLOGGED 0 -10V COM S S TO DUAL ALARM UNIT ,;, � [[I �,,; i , , �,;,,,,, �, �,,, �; � 1; x,1; l;1 l ,. l . b' e Z 1111 1111111►► 111 11111 111. 11111;111111 1111iI1j, ljiii.Ii[�iiliai 6 CND AC MOTOR 7.5HP EXHAUST FAN HENDERSON ENT. BOEING CO. DO NOT SCALE CAD FLE: 30580300 scam NONE OWN a: R08 ♦ NE IGNmo st TOM TOL. UNLESS NOTED .xX .05 .XXX I .020 DATE: 1 1 -9-00 DATE: EPA II ELECTRICAL PACKAGING CO. INC. 12414 HIGHWAY 99 SOUTH /16 EVERETT, WASHINGTON 98204 CSC. No. PAINT BOOTH /1 EXHAUST FAN CONTROLS 0011 - 3058 -D300 3 d L r REMOTE DWYER 3000 PRESS SW. 0 T1 0 T2 VENT HEATa_COOL START STOP . 0 —L_ L FLAME ON 1AAXITROL TEMP SEL 10114 LI 83 - -o — — • -o - -e J Mt 0 M2 • TO BESSAM-AIRE UNIT 10 GFH AGC1 IFu711 AGC1 FU8 II TO VDF S+ SPEED CONTROL 4-20MA GFH 5 s- PSI 24V POWER SUPPLY AIR VELOCITY SENSOR TRANSMITTER + CONT. ,_LER 20 0 14 5 0 15 30 RELAY OUTPUT CFl GFN 24 COM VN CFN N 10 1 - F1 j Ili] I 1 j ji 'J111111111 0 INCH CHINA , . 5 6 7 ' ' • !L LI. Z1 Z GFH ALARM RESET olo • 30 TD1 KEY OPERATION 102 0 01 F IL TER WARNING 45 VLR 46 I' 7 DUAL ALARM UNIT PAINT SOL SHUTDOWN 48 HLR 49 He) 50 40 40 50 8 0 19 5 0-10 FROM 5 I WD TD1 31 33 M2 CFN HENDERSON ENT. BOEING CO. 00 NOT SCALE as rags a0580300 & NONE ma en ROO TOL UNLESS NOTE° .00 mot I .02o ago 11 -9.-00 YR: ELM NC. 110. ELECTRICAL PAOCANC CO. C. 12414 NKRIWAY 119 socntij16 EVERETT. VIAsiocraw s0204 PAINT BOOTH 11 EXHAUST FAN CONTROLS 0011-3058-D301 I 1 WARNING TIMER SHUT DOWN TIMER VICINITY MAP AREA MAP GENERAL NOTES CODE SUNINIARY BUILDING ADDRESS: 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING ABOVE MENTIONED CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. LAND BUILDINGECODEES ORDINANCE P UBBCI 1997 AS MODIFIED BY THE CITY OF TUKWILA; OCCUPANCY GROUP EXISTING:NATIONAL PLB2 OFFICE/FACTORY TENANT IMPROVEMENT: 2ND FLOOR SOUTH OF GRIDLINE 15: PRIMARY USE GROUP B, LABORATORY FOR TESTING AND RESEARCH OCCUPANCY, WITH ACCESSORY OFFICE AND STORAGE CONSTRUCTION TYPE TYPE II, NON-COMBUSTIBLE FLOOR AREAS: BUILDING FOOTPRINT 713,829 S.F. BUILDING GROSS 1,116,306 S.F. FIRST FLOOR 713,829 S.F. SECOND FLOOR 295,878 S.F. TUNNEL ' MEZZANINE 5 S.F. AREA OF CONSTRUCTION 840 0 S.F. S.F.MECII. AITIC AREA OF DEMOLITION 19192 S.F. ALLOWABLE AREA UNLIMITED BUILDING HFIGFIT 111 FT. MAXIMUM STORIES 2 O CCUPANT I.OAC: FIRST FLOOR 3570 SECOND FLOUR 2959 I- 70 (CHANGE) OCCUPANT LOAD OF T.I. 153 -82 PERSONS AS F2 OCC. (200S.F. PERSON) TO 153 PERSONS AS B OCC. (100S.F.ERSON) HANDICAPPED REQUIREMENTS WASHINGTON STATE REGULATIONS FOR BARRIER FREE FACILITIES -1998, CHAPTER 51 -10 WAC AMERICANS WITH DISABILITIES ACT, PUBLIC LAW 101 -336 FIRE PROTECTION FULLY AUTOMATIC SPRINKLERS TFIROUGHOUT SEISMIC ZONE 3 EXTERIOR WALLS (NON BEARIIJG) UNPROTECTED, NON COMBUSTIBLE RING NON- RATED, NON - COMBUSTIBLE# gip O��C INTERIOR WALLS (BEARIB STRUCTURAL FRAME NON- RATED, IJON- COMBUSTIBLE FLOORS NOIJ - RATED ; , y � 1 HOUR (REMODELED) STAIR ENCLOSURES SHAFT ENCLOSURES 1 HOUR � [i P t . ELEVATOR SHAFT 1 HOUR 1 HOUR Ct r 1,; USIA CORRIDORS r i�'t „ OtJ ROOF 1 FIOUR UI' -pt,.a ROOFING CONSTRUCTION FIRE RETARDANT: CLASS A (FM CLASS 1) DESIGN LOADS: UNPROTECTED, NONCOMBUSTIBLE W 25 PSF ROOF SNOW 20 PSF EVER IS GREATER LIVE FLOOR - OFFICE (LIVE) 150 PSF - DEAD 20 PSF (PARTITION) _ MECH & STOR. 125 PSF SFAIRS AND CORRIDOR 150 PSF (PARTITION) OW WIND. - IIO MPH EXPOSURE C C1 �p FILE COPY tfEe t als are � I understand that the Plan Check app r' subject to errors and o missions and aoval of Y i DNf' plans does not authorize the violati o any adopted code or ordinance. Receiof con - tractor'sc•• ofa.I•rovedplansacknledrged. E r) E fl pN f2 0 . 1 " il l / "r � l v U V IS IJ BY j �� ter v jif JAN 1 2 2001 Date No. GOtJSTRUCT10H Permit : -__, ... . MANAGEMENT PROJECT SITE /F FROM DOWNTOWN a s 4 D D ❑ O 7 -127 �//� 0 6i \ // MUS EJN o� s o'' .. V , o . m r g' 8 J 9 5 \ 9 a a �g 9 a ° z „ 00 _3 9s ! � � a ss j / 1 p xeow c E � /p/ k LOT / / �� B � N O y z a SEATTLE soo � , -yam \ I Exlr IN ee� ACC Ex� lr y a � _ PROJECT SITE < ✓✓ 9 04 V 0 s St �; %/ • i s � s -53 s - s5 �V OO 0 , Q �� , i o s -tot s s g - g o ® , - t to -- s - IZ O 3 - vi S 1 PROJECT CH ECKLIST CHE CK BOX ❑ THESE DRAWINGS CONFORM TO THE 1997 U.B.C., U.F.C., U.P.C. ANU THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ❑ ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10 A. ❑ BUILDING R PRINT FOR AREA OF CONSTRUCTION. FLO NUME3ER C'J ❑ NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. TENANT IMPROVEMENT ( STRUOTURAL) F�4 5 SETS OF ARCHITECTURAL DRAWINGS IX 5 SETS OF STRUCTURAL DRAWINGS CI 5 SETS OF STANDARD' DETAILS I3 5 SETS OF ENGINEERING CALCULATIONS I$5 SETS OF ENERGY CALCULATIONS (LIGFTING ONLY) ❑ 5 SETS OF CONSTRUCTION SPECIFICATIONS ❑ 4 SETS OF ARCHITECTURAL DRAWINGS ❑ 4 SETS OF STANDARD DETAILS ❑ 4 SETS OF ENERGY CALCULATIONS 4 SETS OF CONSTRUCTION SPECIFICATIONS ® MECHANICAL, 4 COMPLETE SETS ❑ FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS r CA BRIEF PROJECT NARRATIVE: RELOCATE TWO EXISTING PAINT BOOTHS FROM THE 21 - 01 BUILDING AND REINSTALL AND MODIFY INTO ONE IN THE 9 - 101 BUILDING. FROM SEATTLE - TACOMA DEVELOPMENTAL / / ������� v \a • ■ _ � - �4 \ s O RPORA7 E INPA R KAY TUKWILA a EAST 99 AIRPORT CENTER 57 J \ \ FROM KENT &AUBURN NO EXIT 157 M \ SCALE �! _���y, IaD 9 -101 BUILDING LOCATION 1 \ N NO SCALE REVISION mgt_ RELoc.A'Ctoty' • PARNE floolAk BY cH APPROVED DAIS 3 - 27 - 01 SYM REVISION m BUILDING 9 -101 L LAB RELIlCATION BOEI \G DEVELODME\TAL CE \TER 9725 EAST MARDI \AL WAY SOUTH TU<WILA, WASHI \ETON 98108 APPROVED DATE ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE URAWN E REICIVMAN CHECKED L JOHNSON ENGINEER CHECKED APPROVED APP 2f OVED 11E SUBTITLE 11.10.D0 11.10.00 TITLE ARUM ECTURAL MASTER TITLE SHEET MDL RELOCATION BUILDING J -1O1 COL. A- Z/1 -20 D.0 CURRENT REVISION I #100082 - 00/01 SHEET AO SYMBOL DAIS O -01 JOB NO 4100082 -00/01 COMP 2CEIVc'D C.!TY nF TJ Ilpnn� DAD NO. 9- 101 -AO V DRAWING INDEX SHEET N0. DRAWING NO. SHEET TITLE RE DATE AO q - 1O\- AO - T ‘74... S\AE .• A 0 -27 - 01 G\ ci- \O \-G\ SFAEEV' INDEX E 03-27 -01 A\ °\ -„O\- 2A45 `t E4u4VMEN - t •;:,... Mt- PLANS MECHANICAL SCHEDULES C D \2-0800 01.05.01 M1 9- 101 -M1G 1 •Cl W••0176 PA\N - C BOO SPECtM1. E,x'C�NStoNS C Ol- \4y -01 M3 C AN -G 12.08.00 9 101 2M30 PARTIAL SECOND-TL9 -HV of M4 9- 101 -2M31 PARTIAL SECOND FLOOR HVAC PLAN C 12.08.00 185- -0' 42798799 0 101 M2M30 PARTIAL ATTIC IIVAC PLAN M6 9- 101 -M2M31 PARTIAL ATTIC MECHANICAL PLAN C 12.08.00 •6A- PIPING \fi-- -8-- OL D5 01 O 101 REM11 ROOF- -PLAN IIVAC AND 01.05.01 M 0 101 REM 12 I }BF- PLAN - HVAC ANE M6C •• • • " - • i ` ' NG --A- -- .0-1-05,01 0 101 REM 13 86.9- l - 01.05.01 9 101 RFM18 ROOF PLAN - --HVAC A ND PIPING WE- ft88F Pfd •HVAC - 71ND - PIPING -A 04- 05.01- 0 101 REM-1-6 MGF IIVAC AND PI PING -A-- - 91.-05:91- 9 101 RFM23 ROOF PLAN M7 9- 101 -RFM24 ROOF PLAN - HVAC AND PIPING D 01.05.01 M7A - PIPING -A-- 01- .05-01 9- 101 -RFM25 ROOF PLAN IIVAC AND M7D -8•• 01.05.01 9 101 RFM29 ROOF E LAN - HVAC AIJD PIPING M8 9- 101 -RFM30 ROOF PLAN - HVAC AND PIPING D 01.05.01 MR 9- 101 -RFM31 ROOF PLAN - HVAC AND PIPING D 01.05.01 M10 PIPING--PLAN -91,90 9 101 M2M80 A PARTIAL ATTIC IIVAC M11 IIVAC PIPING PLAN -8-- 01.05.01 0 101 M2M81 PARTIAL ATTIC M12 - - - DELETED - N - - 01.05.01 M13 DELETED -k41-3A - 0 101 Rd11 +- L�ME1G- TUNNEL —Pb M130 PLAN -A- 01.05.01 9-1-91-441•41-1-30. PPMMDING TUNNEL M13C Tom - 6791 - 0 101 TNM13 PLUMBING TUNNEL PLAN -8-14. ' - RbAN• -e- -12.00.00 9- 101 - I M 130 • • • - BING- M15 - PLAN ,• 91.05.01 9 101 1M131 "ARTIAL FIRST FLOOR PLUMBING N 12.08.00 M16 -C 0 101 2M130 PARTIAL SECOND FLOOR 9- 12.08.00 M17 -£- 9 101 2M131 85811• : PLAN "' • ' - 1 2,08.00 1 M10 -E- 9 101 2M230 •• • SECOND FLOOR PROCESS PIPING PLANS -c- 12.08.00 819 9 101 2M231 -PARTIAL- M20 _ --- 9 101 2M200 FIRE PROTECTION SECOND FLOOR PLAN 01.95.01 M21 : C • PLAN -8-- 01.05.01 9 101 2M281 M22 M-8O' ATTIC -B- PARTIAL FIRE PROTECTION -PLAN 01.05.01 -MOO- PARTIAL ATTIC FIRE PROTECTION PLAN .4G-- 01.05.01 9 101- M2M-28 - V 01.05.01 823A .9-1-0-1-857 CONVERTER •M23D •01 CONVERTER OPA-ON NO. 3 -8-- 01.05.01 FEN-DIAGRAM M24 9- 101 -M585 HVAC SECTIONS C 12.08.00 SUPPORT-- ^DETAILS -4.05.01 M24A 9 101 MOOR ROOF PIPING- M2: Q 101 MG87- MCCIIANICAL DETAILS TB-- 01.05.01 •M28- MECHANICAL DETAILS _ 12.08.00 9 101 MOOD M27 --- 1-2798704 -9- 489- 4 MCCIIANICAL DETAILS 41- SYSTEM . -8- 01.05.01 - 9 --N-84 -1500 CONTROL 42-4 ---8- 427987E19— 9 101 1501 CONTROL SCIIEMATIQ SAM A 8 MDL RELOCATION REVISION J# 100082 -00/01 MDL RELOCATION - PERMIT RESUBMIT J# 100082 -00/01 APPROVED LJ BY DLR DLR DLR LJ LJ MDL RELOCATION - REVISION J# 100082 -00/01 MDL RELOCATION - CONSTRUCTION ISSUE J# 100082 -00/01 DATE 11.10.00 11.30.00 12.08.00 DLR 01.05.01 03.27 - 01 SYM REVISION APPROVED DATE E M0L (l @locnTlaN - P Atu - v (30 C- 5100 REGISTERED A000ITECT RONALD SCOTT KRUSE STATE OF WASIIINCION ACCEPTABILITY THIS 5E51GN .AND /0R CHECKED SPECIFICATION IS APPROVED L JOHNSON EROINEEH APPROVED BY DEP, DATE DRAWN M STEVENS CHECKED APPROVED APPROVED DATE 12.08.00 12.08.00 iSL Ativizez Aw ° (t SUBTITLE TITLE ARCHITECTURAL MASTER ISSUE FOR BID SHEET INDEX MDL RELOCATION BUILDING 9 -101 D.C. CURRENT REVISION 100082 -00 /01 SHEET Gi JOB NO. 100082 -00/01 DWG No. SYMBOL 9- 101 -G1 DATE 03-27-01 ' 91 UKVJILA COMP NO. PERMITCENTER 2A10 2A11 2Al2 2A13 2A16 2A17 2A18 2A19 2A22 2A23 2A24 2A30 2A25 2A31i 2A28 2A29 8' HOOD ROLL HANDLER CLEAN TENT (8'x12') B OCCUPANCY 2575 SF.x100 OLF =26 OCC. 2 EXITS REQUIRED WALL MOUNT WALL MOUNT GLASS GLASS MDL WEST ROLL HANDLER TA: E (4'x8') TABLE (4'x8') (30 "x60 ") TABLE (30"x60") 23N15Y 23N1 WALL MOUNT GLASS WALL MOUNT GLASS WALL MOUNT GLASS 13 OCC. 6' HOOD (SANDER GRINDE DUST C•L. 12'-2 1/4" 7' -5 1/4" 2' -6" MIN. CLEAR. WALL MOUNT GLASS 22P15' 4' -3 1/4" K'S ARE (21P17 22P15> 8 OCC. B OCCUPANCY 1523 SF.x100 OLF =15 OC 2 EXITS REQUIRED WALL MOUNT WALL MOUNT ALL A0 GLASS 2GLASS LASS 22P16 WALL MOUNT GLASS WALL MOUNT GLASS WALL MOUNT GLASS 5' -7 1 2" 3' -11 7/8" SYM REVISION MDL RELOCATION 4100082 -00/01 MDL RELOCATION — REVISIONS J# 100082 - 00/01 MDL RELOCATION — CONSTRUCTION ISSUE J# 100082 -00/01 BY DU? DU? APPROVED LJ LJ DATE 11.10.00 11.30.00 DUO LJ 12.08.00 SAM REVISION APPROVED DATE B OCCUPANCY 496 SF.x i 00 OLF =5 OCC. 1 EXIT REQUIRED ENLARGED EQUIPMENT PLAN 24454 SCALE: 1/4 " = 1'0" VES TIBUL 5188 REGISTERED ARCHITECT VOL SCOTT TRUSS TIE L- WASHINGTON ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. WALL MOUNT GLASS DATE DRAWN E REICHMAN CHECKED L JOHNSON ENTIRELY C RFECKED APPROVED APPROVED DATE 12.08.00 12.08.00 SUBTITLE ISSUE FOR BID CONSTRUCTION NOTES: INSTALL, LEVEL AND SECURE RED DEVIL PAINT SHAKER AT THIS LOCATION. PLACE AND LEVEL SHAKER, MULLER AT THIS LOCATION, PLACE AND LEVEL ROLLER AT THIS LOCATION. INSTALL MODIFIED (PER PROPOSAL) SPRAY BOOTH AT THIS LOCATION. INSTALL, LEVEL, AND SECURE CURE ROOM AT THIS LOCATION. PLACE AND LEVEL BAND SAW AT THIS LOCATION. ANCHOR TO THE FLOOR. PLACE AND LEVEL DISC SANDER AT TH'S LOCATION. ANCHOR TO THE FLOOR. PLACE AND LEVEL BENCH GRINDER ON A PEDESTAL AT THIS LOCATION. ANCHOR TO THE FLOOR. PLACE AND LEVEL DUST COLLECTOR AT THIS LOCATION. PLACE AND LEVEL BRIDGEPORT MILL AT THIS LOCATION. PLACE AND LEVEL LATHE (GRIZZLY) AT THIS LOCATION. PLACE AND LEVEL PARALENE COATER AT THIS LOCATION. INSTALL, LEVEL AND SECURE FUME HOOD (32- 004366) AT THIS LOCATION. INSTALL, LEVEL AND SECURE FUME HOOD (31054265) AT THIS LOCATION. INSTALL, LEVEL AND SECURE FUME HOOD (32- 004362) AT THIS LOCATION. INSTALL, LEVEL AND SECURE FUME HOOD (32- 004364) AT THIS LOCATION. INSTALL, LEVEL AND SECURE FUME HOOD (32- 004363) AT THIS LOCATION. INSTALL, LEVEL AND SECURE FUME HOOD (94012809) AT THIS LOCATION. WALL MOUNT RELOCATED GLASS DOOR CABINETS TO THE WALL. AND PROVIDE BLOCKING BEHIND. (TYP.) INSTALL EYE WASH /SHOWER AT THIS LOCATION. SOUND ISOLATION VESTIBULE. EQUIPMENT DETAIL PLANS MDL RELOCATION BUILDING 9 -101 GENERAL NOTES; 1) FIRE EXTINGUISHERS TO BE TYPE ABC-101B, PER NFPA 45, NOT TO EXCEED 75' MAX. TRAVEL DISTANCE. FIRE EXTINGUISHERS HOWN FOR PROXIMITY ONLY. MINIMUM OF 22 TO BE PROVIDED. PROXIMATE FIRE EXTINGUISHER LOCATIONS INDICATED BY g . OF OCCUPANTS OUT THIS EXIT siOA/s sic% / S//4/1 s�T i/. /a no trio kOck 7 9-101.1 KEY PLAN CURRENT REVISION SYMBOL J11100082 - 00 /01 C SHEET 2A454 JOB NO. J100082 - 00/01 DWG N0. COMP N0. LA FAN SCHEDULE MARK SERVICE LOCATION FAN DATA MOTOR SUPPLY NOTES FAN TYPE WHEEL TYPE WHEEL DIA (IN) BLADE TYPE CFM TOTAL S.P. ON WG) FAN RPM DRIVE TYPE HP V -EM BASIS OF DESIGN PH 1 TCF TI50L EFL 18A EFM 17A LASER &. AR TABLE 4A, 34B SNORKEL DUCT ATTIC INUNE UTILITY I® ® 500 1 100 0.50 920 5 10.5 81 1000 2.25 1992 IIIII- in M-ll�'r MI- 460 EBE- 460 3 TCF BCJ -105 1,2,3 EFM 178 B -5 FUME HOOD ATTIC UTILITY UTILITY ® ® CENT 10.5 BI 1100 3.75 3317 3317 3 1CF BCJ -105 1,15,2,3 EFM 18A B -4 FUME HOOD ATTIC 10.5 10.5 131 1100 3.75 3 TEE BCJ -105 1,16,2,3 EFM 180 B -3 FUME HOOD ALEC UTILITY 81 1100 3.75 3317 3 TCF BCJ -105 1 EFM 18C B-2 FUME HOOD ATTIC 1 55 83 10 10 EXV -M18A HOOD 84 �® 460 3 TCF BCJ-105 1,1b,2,3 EFM 18D B -1 FUME HOOD ATTIC UTILITY ® ® = ® ® 10.5 BI SOD 3.75 3317 -© 111211 111211 12 ,r 460 460 3 TCF BCJ -105 1,1b,2,3 EFN 15A B -8 FUME HOOD ATTIC UTILITY 10.5 10.5 RI BI 1100. 1000 3.75 "25 3317 1992 3 TCF BCJ -105 1,2,3 180 SNORKEL HOSE ATTIC UTIUTY 3 TCF BCJ -105 1,2,3 EFN 15 6 EFN 16A E 68 NOT LSHO SNORKEL �� MOO -V--.."--- ATTIC UTILITY 1 1 . U.S 10.5 10.5 [Eci 1000 12 8 10 1000 E25 1992 AIM. 1992 BELT \:•.rl� , �11 7 0 MECUM I 1 3 TCF BCJ -105 _ : 105 1,2,3 � � B'�� 1000 7 AM. 2.25 EFN 16C ILS SNORKEL 7630 r r EFN 17B EFN 18A : ANNEALING OVEN ;6 CURING OVEN HEAT au ;4 • IC ATTIC TUTU URUTY MEM CENT 1 1 ... MDL WEST . ����0 448 0.1 5 _ �� 12.25 BI 1600 1.20 1970 I • � El EXV -N15A 3 TCF BCV -122 to 12.25 BI 1500 1.20 1899 BELT B II E 11 T BELT 1 2 1 4 la - 3 TCF BCV -122 1a EFN 18B PLATEN PRESS HEAT EXH ATTIC MTV CENT 10.5 BI 1000 1.00 1992 1150 I TCF BCJ -105 1a EFP 15A EFP 150 1MT USED PAINT MIXING ROOM ; 13' ATTIC URO1Y ® n BI 300 OM Series Vv' size 12 1 TCF FCJ -75 1a, 3 EFP 15C EFP 15D EFP 15E EFP 15F EFP 16A EFP 16B 8 -13 FUME T 3 8 -14 FUME HOOD B -7 H -2 FUME HOOD SNORKEL B -10 FUME HOOD B-15 FUME HOOD ATTIC ATTIC ATM ATTIC ATTIC ATTIC UTI0TY UUUTY UBUTY UTUTY UTILITY ® ® ® ® ® CENT 10.5 BI 1100 3.75 3317 BELT 2 ®' 3 TCF BCJ -105 1,2,3 10.5 10.5 10.5 BI 1100 1200 3.75 3.75 3317 3415 BELT 460 3 TCF BCJ -105 1,2,3 2 460 3 TCF BCJ -105 1,2,3,9 BI 1000 2.25 1992 BELT 3 TCF BCI -105 1,2,3 10.5 BI 1100 3.75 3317 BELT -I2 3 TCF BCJ -105 1,2,3 10.5 BI 1100 3.75 3317 � -- 3 TCF BCJ -105 1 ,2, 3 EFP 17A SNORKEL EXHAUST ATTIC UTILITY T 10.5 BI 1000 '., 2.25 1992 1695 111- 1 120 3 TCF BCJ -105 1,2,3 EFP 1BA SALT SPRAY CHAMBER EXHAUST ATTIC UOLITY SCENT U.S 81 540 1.20 1 TCF MCI -105 1,1b,2,3 CEP 1813 B -9 FUME HOOD ATTIC UTILITY CENT U.S BI 1100 3.75 3317 - II . , r 3 TCF BCJ -105 3 TCF BCJ -105 1,16,2,3 EFP 186 8 -11 FUME 1100D ATTIC UTNTY CENT 10.5 BI 1100 3.75 3317 1,1b,2,3 EFP 18D B -6 FUME HOOD ATM UTILITY UTILITY UTILITY ® CENT 10.5 BI 1100 3.75 3317 BELT - 460 3 TCF nu-105 1,1b,2,3 EFP 18E BATCH OVEN x'14 ATTIC HIRE 15 15 BI BI 1000 2400 1.00 2.50 1.70 1992 2909 1967 BELT 1 2 NMI 3 4 VIII -E= - 1112IIVSJ 120 460 120 1 TCF MCI -105 3 TCF BCV -150 1a 1,2,3 EFP 18F EFP 186 RO -TAP MACHINE X40 ATTIC UTILITY CENT 10.5 BI 500 1 TCF BCJ -105 1,2,3 EFR IBA SIDEWALL EXHAUST HIGH BAY WALL INUNE ® - - - 75 0.50 760 1 TCF T1OOL 6 2050 202 Series VV size 212 Insulated AL Electric - -- - 1- �IIS1J 3 TCVA 24135 1, 2 EF N16C W PAINT SPRAY BOOTH ATTIC VA ' 24 10000 1.20 1800 7 EF P16C E PAINT SPRAY BOOTH ATTIC VA 11111111 - 24 1100 10000 1.20 1800 12111E1E1 --- 3 TCVA 2405 7 EXV -PIMA 3NORKEL P18A 540 10 LABORATORY VALVE SCHEDULE SCHEDULE - CHILLED SERVES RTUN 14A ROOM MARK SERVICE EXHAUST SUPPLY BASIS OF DESIGN TRIATEK CONTROLS NO. MATERIAL ACTUATOR HMS POT Op NOTES HOOD EXHAUST (CFM) Size (dial SUPPLY (CFM)AIR Size (dia) POLY CHEM RTUN 14A 37,820 36X132 500 1 1,823 21 55 `` \ 202 14.5 12 180 160 2 COLMAC COIL BWL- 36X132- 2R -4F -FE EXV -M1813 HOOD B1 1100 12 31.5X71 496 Series W size 12 205 55 79 10 180 151 1 EXV -MIMC HOOD B2 11110 12 TOX50 490 Series W size 12 156 55 83 10 10 180 160 EXV -M18/3 HOOD B3 1100 12 MILLER'S AREA 5,040 Seres W size 12 316 55 -- 1 55 83 10 10 EXV -M18A HOOD 84 1100 12 1 HC-24P17 Series W size 12 1,600 18X28 469 0.1 50 55 83 EXV -M1713 HOOD 135 1100 12 1 COLMAC COIL BWL- 18X28 -1R -BF -WTI Series W size 12 316 55 -- 1 18X34 494 0.1 63 EXV -N18A HOOD 1316 1200 12 180 160 Series W size 12 COLMAC COIL 13WL- 111X34- 1R -13F -WR 1 HC -22P16 MDL EAST 4,375 25.5050 497 EXV -M17A SNORKEL MI7A 1000 12 8 10 Series W size 12 316 55 -- COLMAC COIL BWL- 25.5X50- 1R -8F -WR I 1 MARK'S AREA 1,050 SAV -22LI7 MAKEUP AIR 0.1 33 7630 6x12 Series Ti' size 612 insulated AL Electric 160 1 1 1 MDL WEST MDL WEST 4,180 30X45 448 0.1 138 55 85 10 10 180 160 I COLMAC COIL MRIL- 30X45- 1R -8F -WR EXV -N15A SNORKEL WISH 1000 12 Series VV size 12 316 SS -- I EXV -MI6A SNORKEL N16B 1000 12 Series V'i size 12 316 55 -- 1 EXV -M15A H00D B8 1100 12 Series Vv' size 12 EXV -N I 6 HOOD B12 1100 12 Series VV size 12 SAV -21N17 MAKEUP AIR 4160 402 Series VV size 412 insulated AL Electric 1 1 1 M DL EAST EXV -P15D SNORKEL P15f 1000 12 Series V! size 12 316 SS -- 1 EXV -P15A HOOD 1313 1100 12 Series W size 12 EXV -P15B HOOD BI4 1100 12 Series W size 12 EXV -P15C HOOD 87 1200 12 Series W size 12 SAO 22P16 MAKEUP AIR 4375 4x12 Series W size 412 insulated AL Electric 1 1 1, 2 JIM AREA EXV -P1 6A HOOD 815 1100 12 Series W size 12 EXV -PITH SNORKEL PI7A 1000 12 Series W size 12 316 55 -- 1 SAV -23P17 MAKEUP AIR 2050 202 Series VV size 212 Insulated AL Electric 1 1 1, 2 SETA EXV -P1813 HOOD B9 1100 12 Seriss W. size 12 EXV -PIMA 3NORKEL P18A 540 10 Series V sae 10 SAV -24P17 MAKEUP AIR 1600 2x10 Series VV 210 insulated AL'. electric 1 1 1, 2 MILLER'S AREA EXV -PIED HOOD 136 1100 12 Series W siz 12 EXV -P18C HOOD BI1 1100 12 Series W size 12 EXV -P18E ELECTROPLA1ING 2400 2x12 Series W Aze 212 '316 55 I EXV -P18F RU-TAP 500 10 Series W size 10 316 S5 1 SAV -22P18 MAKEUP AIR 5040 402 Series W size 412 insulated AL electric 1 1 1, 2 MARK'S AREA EXV -N1613 HOOD MID 1100 12 Series W size 12 SAV -21P17 MAKEUP AIR 1050 12 Series W size 12 Insulated AL SISOUic 1 I 1 OVEN ROOM SAV -23N17 MAKEUP AIR 5075 12 Series W size 12 insulated AL electric 1 1 1, 2 WATER COIL SCHEDULE - HOT WATER I SCHEDULE - CHILLED SERVES RTUN 14A MARK SERVES CFM COIL SIZE WXL I NCHES MAX FACE VELOCITY FPM MAX AIR PRESS. DROP IN WG TOTAL CAP. MBH E.A.T. DB / WB de. F L.A.T. DO / WB de. F GPM MAX WATER PRESS. DROP 1 FT WG E.W.T. de. F L.W.T. de. F MIN. NO. ROWS BASIS OF DESIGN : NOTES HC N14A RTUN 14A 37,820 36X132 500 1 1,823 21 55 `` \ 202 14.5 12 180 160 2 COLMAC COIL BWL- 36X132- 2R -4F -FE r 1 HC -22L17 POLYMER CHEM 7,630 31.5X71 496 0.1 205 55 79 10 180 151 1 COLMAC COIL BWL- 31.5X71- :R -8F -WR H C -23N17 OVEN ROOM 5,075 TOX50 490 3.1 156 55 83 10 10 180 160 I COLMAC COIL PWL- 30X50- 1R -BF -WR 1 HC -22P18 MILLER'S AREA 5,040 30X50 490 0.1 156 55 83 10 10 180 160 1 COLMAC con. BWL- 30X50- IR- 13F -V'4'i 1 HC-24P17 SETA 1,600 18X28 469 0.1 50 55 83 3 10 180 160 1 COLMAC COIL BWL- 18X28 -1R -BF -WTI HC -23P17 JIM'S AREA 2,050 18X34 494 0.1 63 55 83 4 10 180 160 1 COLMAC COIL 13WL- 111X34- 1R -13F -WR 1 HC -22P16 MDL EAST 4,375 25.5050 497 0.1 126 55 132 8 10 180 160 1 COLMAC COIL BWL- 25.5X50- 1R -8F -WR I HC -21P17 MARK'S AREA 1,050 12X28 471 0.1 33 55 82 2 10 180 160 1 COLMAC COIL BWL- 12X28- 1R -8F -WR I 11C -21N17 MDL WEST 4,180 30X45 448 0.1 138 55 85 10 10 180 160 I COLMAC COIL MRIL- 30X45- 1R -8F -WR 1 WATER COIL MARK CC -014A SCHEDULE - CHILLED SERVES RTUN 14A WATER 001 37,820 COIL SIZE WXL INCHES 36X132 MAX FACE VELOCITY FPM 500 MAX AIR PRESS. DROP IN WG 1 TOTAL CAP. MBH 2,062 SENS CAP. MBH 1,524 E.A.T. DB / WB de. F AIM DB / WH L.A.T. 1111 de. Fl I _ MAX WATER PRESS. DROP ► (FT WG) E.WT. (deg F) LW.T. (deg F) MIN. NO, ROWS BASIS OF DESIGN NO 20 45 55 6 COLMAC COIL BWL- 36X132 -612-9F -WTI 1, 2, 3 \ SOW A B AIR HANDLING UNIT SCHEDULE MARK RTU -1114A LOCATION ROOF FAN SECTION DATA WHEEL TYPE EP WHEEL DIA. (IN.) 100 BLADE TYPE VAV MOD. TYPE MIN OA CFM 37,820 TOTAL AIR CFM 37,820 TOTAL S.P. (IN WG) 6.02 FAN RPM 1006 SUPPLY FAN (HP) 75 460 PH 3 MAX SPL• ID 250 HZ COOLING COIL MARK CC -1 HEATING COIL MARK HC -1 FILTER MARK BASIS OF DESIGN GAYLORD ESP490 NOTES 1,2,3,4,5,6 NOTES: GENERAL SEE PLANS FOR EXACT UNIT LOCATION AND CONFIGURATION NOTES: 1 PER GAUCHO JOB / 00 -6837 2 100% OA UNIT 3 VAV /VFD UNIT 4 CONFIRM ORDER WITH All OPTIONS MTH DESIGNER PRIOR TO FINAL PURCHASE. 5 DLR HAS BEEN INFORMED BY NOP,' (GAYLORD) THAT THIS IS AN 8 W7( LEAD TIME. 6 12/08/00 ISSUE REVISION: REV,. CFM TO MATCH PLANS GENERAL NOTES - LEGEND: HMS POT Dp 1 12/8/00 ISSUE REVISIONS: DELETED LFCP (LAB FLOW CONTROL PANEL) 2 12/8/00 ISSUE REVISION,: TEASED CFM TO MATCH PLANS REVISION HOOD MONITOR CAUBRAIED VALVE MTH POTENTIOMETER VALVE WITH DP SWITCH MDL RELOCATION - PERMIT ISSUE .4100092 -00/01 MDL RELOCATION - REVISION '100082 -00/01 MDL RELOCATION - CONSTRUCTION ISSUE 4100082 -00/01 MDL RELOCATION - POST - CONSTRUCTION ' -00/01 BY DLR DLR DLR DLR APPROVED RP RP RP DATE 71.10.00 11.30.00 12.08.00 01.05.01 SY REVISION *SOUND POWER LEVEL , REFERENCE 10E -12 WATTS APPROVED DATE NOTES: 1 12/08/00 ISSUE REVISIONS: CC -2 DELE D 2 12/08/00 ISSUE REVISIONS: REVISED CFM TO MATCH PLAN 3 01/05/01 TENSION: CORRECTED GPM GENERAL NOTES: NOTES: NI v 112/8/00 ISSUE TENSION: CHANGED CFM TO MATCH PLANS 2 01/05/01. REVISION: CORRECTED GPM NOTES: 1 FAN ACCESSORIES TO INCLUDE: WEATHER COVER, VENTURI DISCHARGE CAP, SHAFT SEAL BACKPLATE FINS to FAN ACCESSORIES TO INCLUDE: WEATHER COVER 1b 45 degree discharge, CW orientation (12/08/00 ISSUE REVISION) 2 Group 3E Epoxy - Entire Fan 3 Spark Resistant Construction - Type B 4 This is existing fan with known characteristics listed. Relocated by G.C. - Relag with this number. 5 To be Installed In exhaust duct work, 5' from hoo.,. 6 T. .e inst ed t exhau side 6 en .sure ®!G DESIG FO • - DAD FOR FER CE; FA l OR 8 12/22/00: RELOCATION OF B -16 CAUSED IT TO BE RECLASSIFIED AS HAZARDOUS, THEREFORE H -1 LABEL 9 12/22/00: RELOCATION. OF B -7 CAUSED IT TO BE RECLASSIFIED AS HAZARDOUS, THEREFORE H -2 LABEL 10 12/22/00: ADDED GENERAL NOTES: - ALL UTILITY SET FANS TO BE CCW ORIENTATION UNLESS OTHERWISE NOTED. (12/08/00, ISSUE REVISION) ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE K HAWKINS CHECKED K. PAULSON ENGINE HECKED APPROVE APPROVED SUBTITLE TITLE MECHANICAL MASTER mop •oG ISSUE FOR BID MECHANICAL SCHEDULES MDL RELOCATION BUILDING 9 -101 D.C. CURRENT REVISION 100082 -00/01 SHEET M1G SYMBOL D JOB N0. 100082 -00/01 DWG N0. 9- 101 -M1G DATE 01.05.01 COMP NG: 10' D.D. 4- MUFFLER 030' OPENING • ! 27' H I 27° I - T - - 1 - F1 I I I I I FRON I I ! I I I TOP ELEVATION - 1 - Scale: 3/16" = 12" T ELEVATION Scale: 3/16" = SUPPORT BEAM r- I LJ I 030' ‘r ' PANELS ARE PHANTOM LINE NEW 15' WORKING DEPTH 3'-6° 3'-6° 1' 12' 24' ;71$7 96' DOOR 99' WIPER STRIP 2'— B I 10' 181- e 120' 114' 3 -3' B SUPPORT BEAM ---\ 1 -12' 1:1 r .......... — r-E-- — H 1 0 ,I I o H '1 I D,D, 1 L j 1 ' 9'-10°11 67-6 II Fl DOOR Li 1.1 ii HEIGHT 11 ,. . . . Scale: 3/16" = 12" e 10' -I 86' DOOR 114' OPEN 45' DOOR B ---- - 4- EXISTING PANELS ARE IN PHANTOM LINE SECTION A—A Scale: 3/16" = "12" IG4 9' DOOR \WIDTH 3'-6' 15' WORKING DEPTH 22'-4' O.D. SIDE ELEVATION _ T CUT PANEL JOB SITE 10' O.D. 9'-10"1. 5et UOT BOOTH CONTROL PANEL (BY OTHERS) 2'- 2' 8' DOOR HEIGHT 6' 3'-6" 15' WORKING DEPT' 3'-6" NEIA) m SLIDING DOOR -- 45' WIDE O(TOCa LB CD SLIDING DOOR 81' WIDE 15' WORKING DEPTH 22'-4" SECT ON B—B Scale: 3/16" = 12" RECEIVED JAR 0 5 2001 G ' NE TOECrigi l cr "' DATE CHECKED REV A B APPROVED DATE DESCRIPTION INITIAL RELEASE DOOR WIDTH I DATE 12/20/00 11'61)--" \R avo\Rs SUPPORT BEAM 01) 18 GAUGE GALVANIZED STEEL PANEL 02) BOLT CONSTRUCTION ' UCTION ; INSIDE OF BOOTH IS SMOOTH 03) 2 -16"X54" LIGHT WINDOWS WITH 1/4" CLEAR TEMPERED GLASS 04) 2 -FOUR TUBE LIGHT FIXTURE, VAPOR TIGHT 120V. (LESS 'TUBES) 05) ALL ELECTRICAL AND (PLUMBING TO CONFORM TO LOCAL CODES. 06) CUSTOMER T' 7 A "NO SMOKING' SIGN IN A CONSPICUOUS LOCATION ON ON BOOTH PER NEC NFPA 33,8,11 07) AUTOMATIC FIRE EXTINGUISHING SYSTEM BY OTHERS. 08) PLANS TO SUBMITTED I TO FIRE PREVENTION BUREAU PRIOR TO OPERATING PAINT SPRAY BOOTH. 09) ELECTRICAL HOOK UP BY OTHER. 6 10) HOOK UP SHALL OE IN ACCORDANCE WITH N.E.C.-70 NFPA-33 AND NEC-ART. 45. 1.01 II Two TITLE MODEL 5' Fra BLE,EKER BROS. _ SO 54883 CUSTOMER NAME HENDERSON ENT. DRAWN BY. HERRERA A. WORK ORDER II WO-01770 SHEET 0F 1 1 wuttows 4 cu FIP4mc 13 s-QPN_A.eb 0 V) -ED 3E Lor t lob scrz. fut. PA u64,11-- NOW NOTES: UNLESS OTHERWISE SPECIFY TR ACK --\\ UNLESS OTHERWISE TOLERANCES SPECIFIED DIMENSION XX t1/2' ANGLES= ±2 ARE IN FEET & INCAS XX X = ±1/4' 10868 DRURY LANE, LYNWOOD, CA, 90262 I www.Meekerbros.com 91\114-1. SPECIAL EXTENSIONS DRAWING TYPE APPROVAL SCALE 3/8' = 12' 3' 6' DATE 11/7/00 DWG. NO. WD-01770 W0-01769 —2' SIZE 0 PEFINTIT cENTER 2M10 2M11 2M12 2M13 2M16 2M17 2M18 2M19 2M23 2M24 2M25 2M29 2M30 ;2M� j 34/34 MAU U PA NT 36r EA UP EF -P15F 16/12 24/12 , VENN L = I�IIiC!l:J ©I 18/16 20/20 12/8 (TYP) 24/24 POL(MER CHEMICAL l © 112 1t l�rsis�s r - 2L17�- i 100 D -, CFM (4 TY 24/16 100 D -2, 350 CFM (3 TYP) C -21 P17 H N17A C1 14/10 1 20/12 16/12 120 UP V EH P18A 120 RG -1, 500 CFM 2M31 M585 SYM A REVISION MDL RELOCATION — PERMIT SET 41100082 -00 /01 MDL RELOCATION - REVISIONS 4100032 -00 /01 C MDL RELOCATION — CONSTRUCTION ISSUE J#100082 -00/01 BY DLR DLR DLR APPROVED RP RP RP DATE 11.10.00 11.30.00 12.08.00 SYM n REVISION NY APPROVED J _IL r EF - B SWITCHES EF -N18A PROVIDED EF -N 88 BY DIV , EF -P18 16 (TYP), STAIR h5 r _L J r ON i JJ _!L 120 D -1, 560 CFM (9 TYP) MILLER', ET 2 0/12 EF-P186 N PARTIAL D FLT' G • +A PLAN SCALE: 1/8 " =1' -0" DATE , 6 05 /0O/S TO P-/f'4/7 / //o. 00 - -I eLardcrElviva. EXPIRES: 12 6/02 17 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. HAWKINS 12.08.00 K. PPA EL 12.08.00 t TECRED APPROVED APPROVED TITLE £ €O 5 /c A��S 70 "F2mrr sET / / /0.00 ISSUE FOR BID SUBTITLE PARTIAL SECOND FLOOR HVAC PLAN MDL RELOCATION MECHANICAL MASTER BUILDING 9 -101 COL. 6- 5/15 -19 GENERAL NOTES: 1� CONT. UP ON M2M31 CONT. ON 2M3 SEE DETAIL REFER TO DETAIL * ASBESTOS NOTIFICATION: A good faith survey of the work area has been conducted and osbestos containing material may be present in the VAT tile & mechanical ductwork. Do not remove, damage or disturb any asbestos material adjacent to the work area. Please contact Boeing Facilities Department if asbestos containing material is damaged or discovered that is required to be removed to support work. CONSTRUCTIO N NOTES: r KEY PLAN pr p II II' D.C. CURRENT REVISION 100082100/01 SHEET s SYMBOL 2M31 JOB N0. 100082 -00/01 DWG NO 9 -101-2M31 @ ,v zr 2J NH'( - 2 21101 NOTED DATE 12.08.00 LLLL jj�� CEIV 0 ap CFT "A COMP N0. PERMIT CC1 2A10 2A11 2Al2 2A13 2A16 2A17 2A18 2A19 2A22 2A23 2A24 2A25 2A28 2A29 2A30 ; 2A�� CONYD UP ON RFM31 4 SAV -23N HCL . 1 ELEC EQUIP AREA EXIST. ROOF OPENING, (NO DUCTS OR PIPING) 62/200 16/12 DN EF Ni6C EXIST. ROOF OPENING SAV- 21N17I L 24/24 DNJ , ..--HC -21N17 I 34/34 r EF MY7A EF P18G 16/12 .eA 18/18 UPA r - 24/24 SAV -22P18 HC -22P18 EF P18E 36x16 } 12 "0 1.. - --- --- -- _1..4" EF P15C L - HC -23P17 24/24 I SAV -22P16 1 11 HC -22P16 lily iI 24 "x12" I H I SAV -23P17 II EF P15F EF P15E EF P166 EF P17A i II M 20/12 , I EF M17B 111 11 "91 0 11111111167.„ =j SAV 24P 7 o HC 24P17 �� -_•4® EF M18A EFP18B EF P180 EF M188 EF M18C 18D M2M31 M585 MDL RELOCATION - PERMIT REVISION J#100082 - 00/01 SON A B MDL RELOCATION - REVISION 4100082 -00/01 MDL RELOCATION - CONSTRUCTION ISSUE J4100082 -00/01 REVISION By DLR OLIN DLR APPROVED RP RP RP DATE SYM 11.10.00 11.30.00 12.08.00 BY I ,APPROVED DATE PARTIAL ATTIC HVAC PLAN SCALE: 1/8"'=1'-0" Ii i //0/G i i �Q�ckX5'O.tIS s�.t/GE 5E7 //./0.00 EXPIRES: 12 6/02 Ito � ACCEPTABILITY THIS DESIGN AND /OR SPECIRCATION 5 APPROVED APPROVED BY DEPT. DATE DRAWN K. HAWKINS C C ED APPROVED APPROVED DATE OLQ7 12.08.00 12.08.00 SUBTITLE TITLE ,V/RU/4(/ S sirt/l� scr //.10.00 ISSUE FOR BID PARTIAL ATTIC HVAC PLAN MDL RELOCATION E3UILDING 9 -101 MECHANICAL MASTER COL. N- S/15 -19 CONTD ON M2M30. CONT'D ON 2M30.J E> CONT'D ON RFM30. GENERAL NOTES D.C. 9 -101.1 KEY PLAN CURRENT REVISION SYMBOL i 0008T — DO /01 C SHE t1 2 M 3 1 100082 -00 /01 DWG No, 9- 101 -M2M31 0 CITY Of 111081.0 APPROVED MAY 2 21131 AS NOTED DATE 12.08.00 10 6 COMP N0. RECEIVED CITt ,,,r I UVULA SY A MDL RELOCATION — PERMIT REVISION MDL RELOCATION - PROGRESS', SET J # 100082 -00/01 4100082 -0D /01 MDL RELOCATION - CONSTRUCTION ISSUE J #100082 -00/01 MDL .RELOCATION — POST— CONSTRUCTION ISSUI#100082 -00/01 APPROVED RP 11.10.00 11.30.00 REVISION APPROO 12.08.00 HEC ED APPROVED, ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION. IS APPROVED APPROYED BY DEPT. DATE 12.08.00 DIR ALA ALA RP 12.08.00 01.05.01 PARTIAL ROOF HVAC PLAN SCALE: 1/8"=1'-0" 8'= 1' -0 VIDED WITH UNIT) VI TOLE MECHANICAL MASTER ROOF PLAN - HVAC AND PIPING MDL RELOCATION BUILDING 9 -101 COL. 11- 15 /J -N LEGEND: - -- VTR — CHWS - - CHWR- -IXI - 1- VENT THROUGH ROOF - CHILLED WATER SUPPLY CHILLED WATER RETURN GATE VALVE, OPEN /CLOSED LIFT CHECK VALVE a I PIPE REDUCER BUTTERFLY VALVE GENERAL 'NOTES: 1. ALL CHILLED AND HOT WATER PIPING IS COVERED WITH FIBERGLASS INSULATION AN ALUMINUM VAPOR BARRIER. Ll _> ROOF CURB DETAIL * ASBESTOS NOTIFICATION: A good faith survey of the work area has been conducted and asbestos containing material may be present in the VAT tile & mechanical ductwolk. Do not remove, damage or disturb any asbks,s material adjacent to the work area. Please contact Boeing, Faacilities Department if asbestos containing material is damaged or discovered that is required to be removed to support wo!k. CONSTRUCTION NOTES P. REVISE EXISTING MAU FROM DOWNFLOW CONFIGURATION TO HORIZONTAL! DISCHARGE. ACCORDING TO BESSAM -AIRE, THIS CAN BE ACCOMPLISHED BY ROTATING BLOWER DO. DEG, REPOSITIONING MOTOR (IF NECESSARY), AND ADDING NEW DRIVE BELTS. COVER EXISTING DOWNFLOW OPENING WITH SHEETMETAL COVER. RESEA CABINET FOR AIR- TIGHTNESS. i L' INSTALL 6" CH }NS & R AS INDICATED. SUPPORT AS INDICATED. I CENTERLINE 0 PIPE APPROX. 3' -6" ABOVE ROOF SURFACE. RFM10 RFM2 RFM21 ° E RFM11 I I RFM1 RFM1f 2 RFM2$ I I I' RFM2d RFM3I RFM40 000 F RFM12 REM18 RFM30 I RFM36 I 'RFM41 0 ® 0 REM13 RFM1E RFM25 RFM31 RFM37 RFM42 RIJ"M4 RFM14 RFM20 RFM26 RFM32 RFM38 RFM43 RFM46 RFM15 RFM21 RFM27, RFM34 ,o RFM39 RFM44 RFM47 ROO D.C. I °III In.' CURRENT REVISION SYNBOL i #100062 D SHEET RFM24 O —O � zo 0 —O Mpy 2 BORE k,$ ROEE DATE 01.05.01, M7 JOB No. J # 100082-00/01 COMP No: DWG NO. 9- 101 -RFM g orrula�ILA CXPANSION JOINT / — X \= I ZITI�t1 IIl�I111IilL1IiICi1[t,I[I IPIiLLLllllti -- -1Ti U1I111UI:D:11LLLIDIlLll111.:D11 U11T111LI:1 L__ -- - ._ -- = -- 111111(1] 1 - 1-.111111.11.01011 - 1111.11 __ - - -- LLTIT f _.� r - - - 1i 1 t -� ! L1T 'LU -- - I I Ll - -- — -. _ :_:: _ 5 f- LI ' j k r L l� '111 - - 11 1_ L- .- .111 I-li . 1T2 = - 111U' I - �-. i , -. I II LI LI:III RFM24 M586 6" CHWR -- , : �- - ;1U, L -. 6 " CHWR [ -� 1r FLUID [IL TAIR #1, � t F.. 11ICI 11 ROOF DRAIN, r _ �` — = ! RFM24 M566 F I l I LITEiI I! ITIT. ' --{•+ i OVERFLOW DRAIN ` ) h I I i i - t I-- , ; r L / 1 L1 ACCESS I I I ;' k I ,_ r �1 LIiI F I — _ .L ' 1 ( . . F I L L I n 1 ' I Ir_ Li X . . _ i I I i I I _ i - 4 Q I = 7 l i ( 1 L J - N / y X / 1ILCLICfT- - 11.IW111_ I�1`U i I . {i ; I ii RFM24 M586 OA a ACCESS' STAIR #1, 1 _ fSi L 1 _ t IIL in - I r \\ �) II lk i. RTU -NI4A • UNIT HEATERS (PRI ( �, OA - MAU-M14B ! I I COOLED DENSER ld i Lim f: IT1 - ]lI' I ' F- I ' 11��11 li 1� OF 24 M586 I I r ,-4-�_ ., `/ �11C • t � i l/ ( I I _® I l ROOF VENT r� II II A MAU M14A N _ N I II I 2 K I 411 I - � ' ' Jr CONT. ON RFM30 - 1 (1/1 hi SY A MDL RELOCATION — PERMIT REVISION MDL RELOCATION - PROGRESS', SET J # 100082 -00/01 4100082 -0D /01 MDL RELOCATION - CONSTRUCTION ISSUE J #100082 -00/01 MDL .RELOCATION — POST— CONSTRUCTION ISSUI#100082 -00/01 APPROVED RP 11.10.00 11.30.00 REVISION APPROO 12.08.00 HEC ED APPROVED, ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION. IS APPROVED APPROYED BY DEPT. DATE 12.08.00 DIR ALA ALA RP 12.08.00 01.05.01 PARTIAL ROOF HVAC PLAN SCALE: 1/8"=1'-0" 8'= 1' -0 VIDED WITH UNIT) VI TOLE MECHANICAL MASTER ROOF PLAN - HVAC AND PIPING MDL RELOCATION BUILDING 9 -101 COL. 11- 15 /J -N LEGEND: - -- VTR — CHWS - - CHWR- -IXI - 1- VENT THROUGH ROOF - CHILLED WATER SUPPLY CHILLED WATER RETURN GATE VALVE, OPEN /CLOSED LIFT CHECK VALVE a I PIPE REDUCER BUTTERFLY VALVE GENERAL 'NOTES: 1. ALL CHILLED AND HOT WATER PIPING IS COVERED WITH FIBERGLASS INSULATION AN ALUMINUM VAPOR BARRIER. Ll _> ROOF CURB DETAIL * ASBESTOS NOTIFICATION: A good faith survey of the work area has been conducted and asbestos containing material may be present in the VAT tile & mechanical ductwolk. Do not remove, damage or disturb any asbks,s material adjacent to the work area. Please contact Boeing, Faacilities Department if asbestos containing material is damaged or discovered that is required to be removed to support wo!k. CONSTRUCTION NOTES P. REVISE EXISTING MAU FROM DOWNFLOW CONFIGURATION TO HORIZONTAL! DISCHARGE. ACCORDING TO BESSAM -AIRE, THIS CAN BE ACCOMPLISHED BY ROTATING BLOWER DO. DEG, REPOSITIONING MOTOR (IF NECESSARY), AND ADDING NEW DRIVE BELTS. COVER EXISTING DOWNFLOW OPENING WITH SHEETMETAL COVER. RESEA CABINET FOR AIR- TIGHTNESS. i L' INSTALL 6" CH }NS & R AS INDICATED. SUPPORT AS INDICATED. I CENTERLINE 0 PIPE APPROX. 3' -6" ABOVE ROOF SURFACE. RFM10 RFM2 RFM21 ° E RFM11 I I RFM1 RFM1f 2 RFM2$ I I I' RFM2d RFM3I RFM40 000 F RFM12 REM18 RFM30 I RFM36 I 'RFM41 0 ® 0 REM13 RFM1E RFM25 RFM31 RFM37 RFM42 RIJ"M4 RFM14 RFM20 RFM26 RFM32 RFM38 RFM43 RFM46 RFM15 RFM21 RFM27, RFM34 ,o RFM39 RFM44 RFM47 ROO D.C. I °III In.' CURRENT REVISION SYNBOL i #100062 D SHEET RFM24 O —O � zo 0 —O Mpy 2 BORE k,$ ROEE DATE 01.05.01, M7 JOB No. J # 100082-00/01 COMP No: DWG NO. 9- 101 -RFM g orrula�ILA * ASBESTOS NOTIFICATION: has been conducted A good faith 'survey of !the work are and asbestos containing material may be present, in the VAT Mal& mechanical ductwork. I D damage or disturb any asbestos ma not remove, erial adjacent to the work area. Please contact Boeing loan& Department if asbestos containing material is damaged or dscovered to be removed to support work. that is required 1) 2 RFM30 M529 E (STING ROOF -TOP (nUVERED PENTHOUSEI X CL NG COIL Ail G COIL F LTER I II[ I Iii i I I t 4 1tW� y t - t'1WR 1 I I RFM30 M586 1_'Jllm 1 3/30 SOUN LINED S PPLY AIR (JCT 1 THRO ODI Inn L I 1 _I_J I ra ®:M®C C :111®lMINVIIM, .. 1111111M E! - -__ -- I ---- IIM- - - -, 1 =MIME AVM= L1 INI 1 1 'll JIIEL T.I.LELTI � 1 - EXISTING RO LOUVERED P FILTER AND PULL SPACE Ji F� �P t H USE SCALE: 1/8 " -1 0" 1 1 - OUTSIDE AIR 1 CAL) RFM30 M586 - ;I _ I I J - -1 F-i PARTIAL HVAC ROOF • rr Sj 1 4" HWS L � I j 1 4 HWR t,, I 28 "x36' DN PLAN O l it i : I RFM24 M586 RFM30 M586- k: 1 ROOF PEN. GOOSENECK ra k =tat LI,P.'JL_m1 6" CHWS 6" CHWR Li— L1— ! j r1 r' ] RFM30 M585 CONT ON RFM24 r7 I I t 1 I F I- i I i 1--- N-- 4- - - - -+ + + ---1--- =, --- -- -6" CHWR --- i 1 L r . 1 - 6" CHWS i 4„' HWS - T j ,. 4" HWR RFM24 M586 r•x•1 I UII \ /t ▪ 72 "x42" - - - -- II JJTlJ !u;r.;risrTTJJlff lIlU I lJ EI] LEII�J 84 "x84" - CONT'D DN ON M2M30 CONT'D ON RFM30 • MA DUCTS OVE• SA DUCT RFM24 M586 2" CHWS & R DN EX. OPENING LEGEND: VTR — CHWS - - CHWR- --Da -- —►t— VENT THROUGH ROOF CHILLED WATER SUPPLY CHILLED WATER RETURN GATE VALVE, OPEN /CLOSED LIFT CHECK VALVE PIPE REDUCER BUTTERFLY VALVE GENERAL NOTES: 1. ALL CHILLED AND HOT WATER PIPING IS COVERED WITH FIBERGLASS INSULATION AND ALUMINUM VVPOR BARRIER. � ? --I 'HWS /HWR DOWN THROUGH ROOF. SEE • DRAWING i09- 101 - -207 FOR CONTINUATION. CONNECT 2j1/2" HWS /HWR TO AH -RJ18A HEATING COIL. SEE DETAIL I RFM30 M529 rTh 3" CHWS /C! -IWR, CONNECT TO AH - RJ18A COOLING COIL. SEE DETAIL RFM30 M529 CONSTRUCTION NOTES: 1�. INSTALL 6" CHWS & R AS INDICATED. SUPPORJ AS INDICATED. CENTERLINE OF PIPE APPROX. 2' -5' ABOVE ROOF SURFACE. WIDEN STAIRWAY. (NEW) 3" INSULATED CHWS/CHWR SEE DWG. 109 -101- 4954 -M;1' FOR CONTINUATION C H - -y J-JELL U 11 � 1 111, SYM A REVISION MDL LAB RELOCATION — PERMIT SET 4100082 -00/01 APPROVED RP BY OLR DIE OLR DIR RP RP DATE 11.1 11.30.00 12.08.00 01.05.01 SYM MDL LAB RELOCATION — REVISION 4100082 -00/01 MDL LAB RELOCATION — CONSTRUCTION ISSUE4100082 -00/01 MDL RELOCATION POST—BID 'ISSUE 4100082 -00/01 REVISION APPROVED DATE ,i_ ACCEPTABILITY THIS DESIGN, AND /OR SPECIFICATION IS APPROVED, DEPT. DATE DRAWN K. - HAWKINS CHECKED K. PAULSON LNG INEEC C EC ED OATS 12.08.00 12.08.00 SUBTITLE ROOF PLAN HVAC AND PIPING TITLE MDL RELOCATION BUILDING 9 -101 CURRENT REVISION' 1 #tOg082 -00 /O1 SYMBOL D SHEET' JOB Np. i 100082 -00/01 DATE 01.05.01 M8 COMP NO. 0 35039 �OF STERY' �4 • S 7 0NAL FN APPROVED APPROVED REM10 RFMib RFM2 RFM28 RFM11 RFM1T, 2 RFM2b RFM2 HREMY. RFM40 RFM12 RFM18 RFM24- RFM39) / A 0 0 0 RF413 RFM14 RFM19' RFM20 RFM2 RFM26 RFM32 RFM46 RFM15 RFM21 RFM27� I RFM34 RFM36 37 RFM38 RFM41 ;RIjM42; RFM43 RFM39 RFM44 RFM47 zo MECHANICAL MASTER COL J-N/15-19 D.C. 9- 101 —REM TO 0 0 —0 0 9 of menu' t4A' — 2 2001 XS NOTED gUttDtliG OT 111111'1 RFM i1 M5$6 T OVEFFLOIa ROOF DRAII Tm . l _ I .. RFM31M585 EF -R18A l L ENTI- OUSE • JUV R, .� 180 GOOSINECKI TOP ® 2' A.F.F. LULU ACCESS LADDER L up 1E1 ACCESS STAJfi _= 1TJJffiI _ — — _ - - -- I f T 18/1 DN FM31 M585 MIME TI.1 LTSII� 111 !l II L PARTIAL ROOF HVAC' PLAN SCALE: 1/8 " =1' -0 ACCESS P PTFORiv SYM REVISION MDL RELOCATION — PERMIT I Jij100082 -00/01 MDL RELOCATION REVISION J#100082 -00/01 MDL RELOCATION - CONSTRUCTION ISSUE , JN1 00082 - /Ol DLR APPROVED RP DATE 11.10.00 DLR RP 11.30.00 DLR RP 12.08.00 D MDL RELOCATION - POST- CONSTRUCTION ISSUI#100082 -00/01 DLR 01.05.01 SYM REVISION APPROVED DATE BO L� /N4'm a� �, ' 35aJ9 0 •�,' b c $4 , ... 4'01 O N AU G ' o IOtr7 A PROVE... MECHANICAL MASTER COL. N- S/15 -19 *' ASBESTOS NOTIFICATION: A good faith survey of the Work am has been conducted and asbestos containing material ay be present in the VAT tile & mechanical ductwork. ray not remove, damage or disturb any asbestos aterial adjacent to the work area. Please contact Boeing Facili ies Department it asbestos containing material is damaged o discovered that is required to be removed to support work. SSUE FOR BID CONSTRUCTION' PLENUM SHOWN BAY AREA' E OF RFM10 RFM1I RFM2 ©00 RFM1i 2 REM 213 RFM28 RFM2 RFM30 O ® I ® RFM12 RFM13 RFM18 RFM24 RFM19 RFM(O RFM25 RFM26 RFM31I RFM 2 //, RFM15 RFM21I RFM27 RFM34 I* xo RFM11 - REM3.` RFM36 RFM37 IRFM50 RFM39 RFM40 RFM41 RFM42 IRFM RFM44 RIiM45 + RFIv46 RFM47 ROOF LEGEND: - VTR — CHWS - - CHWR — —►4— a - - I , GENERAL NOTES: 1. ALL CHILLED AND HOT WATER PIPING IS COVERED WITH F BERGLASS INSULATION AND ALUMINUM VAPOF1 BARRIER. ,:;LAN i. DN ON M2M31 => CONT. ON RFM30 KEY PLAN DWG N0. D.C. VENT THROUGH ROOF CHILLED WATER SUPPLY CHILLED WATER RETURN GATE LIFT PIPE BUTT RFM 4 1111' '11111 Itl UI. VALVE, OPEN /CLOSED ;HECK VALVE REDUCER RFLY VALVE J' NOTES: ON ROOF PLAN FOR HIGH COLUMN LINE R. 0 O 0 0 -0 0 O ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DOES BY DEPT. DATE DALE DRAWN K. HAWKINS CHECKED K. PAULSON ENGINEER CHECKED APPROVED 12.08.00 12.08.00 SUBTITLE ROOF PLAN HVAC AND PIPING TITLE MDL RELOCATION BUILDING 9 -101 CURRENT REVISION 100082- 00/01 SYMBOL D SHEET R F M 3 1 JOB NO. 100082 - 00/01 DATE 01.05.01 COMP NO. VAa UKWII$ 9 - 101 —RFM31 ROOF - RFM31, M585 ATTIC M2M31, RFM31 M585 SCALE: 1I/8 " =1' - M585 EF -P188 SECTION LOOKING NORTH H© A COLUMN LINE 38 M585 SCALE: 1/4 " =1' -0" ATTIC ELEVATION LOOKING EAST @ COLUMN LINE R HIGH BAY ROOF TOP 'OF PARAPET BRACE © 5' -0" O.C. - HIGH BAY ROOF BEYOND METAL PANEL EXTERIOR HIGH BAY AREA BEYOND 84/84 RTU-N14A 72/42 SECTION 'LOOKING NORTH •. ►�► ► 17 ATTIC WALL ISSUE FOR BID MAU -M14A I 11 [ ij - = 1 _ 1 1 1 P OLYCHEM LAB 122L171 WALL CAP WITH BDD EF -R18A n SECTION @ PLENUM FAN M5851M585'SCALE: APPROX. 1/4 " =1' -0" - A , - 1 36/12 _ - EXISTING RELIEF AIR PENTHOUSE (TYP) FF - N16B 2M30, 2M31, M2M30, M2M31, RFM30, RFMf31 M585 SCALE: '1 /8'' =1' -0 RB ATTIC T SAV -22P16 HC -22P16 h101 WEATHERPROOF CAP ON PAINT SPRAY BOOTH EXHAUST (2 TYP) M585 . EF -P16A , EF -P16C T CORRIDOR 121P181 \ � /� � ✓ � EF -P17A JIM'S AREA 123P17I CONSTRUCTION NOTES 1 REUSE EXISTING RELIEF AIR PENTHOUSE PENETRATIONS FOR �J1EW EXHAUST AIR DUCTWORK. REMOVE ALL DAMPENS & ASSOCIATED CONTROLLERS. RETJA�INIPENTHOUSE SHELL FOR WEATHER & ROOF PENETRATION PROTECTION. INFILL OPEN AREAS WITH SHEET METAL & R -19 INSULATION. TERMINATE RELIEF A R DUCT AT EXISTING LOUVERS. ROUTE TOP OF SA UCT AS CLOSE TO THIS DIMENSION AS POSSIBLE. EXHAUST DUCTS TO BE HIGHER (TYP) [BOTTOM OF EA DUCTS: 10' -0" ABV. ATTIC FLOOR TYP).] SUSPEND SNORKELS WITH SEISMICALLY BRACED UNISTRUT. CONSTRUCT SEALED PLENUM: CAULK ALL SEAMS. SEE M2M31 OR RFM31 FOR WIDTH. © HEIGTH SHOWN (14' 0 ") IS APPROXIMATE. TOP OF PLENUM SHOULD 6" ABOVE TOP OF EF -R18A. HIGH BAY ROOF OF u 14 01 - 2 201 I!5 pp1ED D11t1 DTI+* DMg \ x.o, /c / SE7- /i. /o.00 SYM A REVISION MDL LAB RELOCATION - PERMIT SET J #100082 -00/01 MDL RELOCATION - REVISIONS J #100082 -00/01 MDL REVISIONS - CONSTRUCTION ISSUE 4100082 -00/01 SLR DIR DIE APPROVED RP RP RP DATE 11.10.00 11.30.00 12.08.00 SYM '. REVISION APPROVED DATE WN A BRA CCEPTABILITY K: HAWKINS THIS DESIGN AND /OR CHECKED SPECIFICATION IS APPROVED !:!! APPROVED BY DEPT. DATE. APPROVED PROVED DATE 12.08.00 12.08.00 SUBTITLE IiVAC SECTIONS TITLE MECHANICAL MASTER MDL RELOCATION BUILDING 9 -101 D.C. CURRENT REVISION 100 8200/01 SYMBOL C SHEET M585 JOB NA 100082 -00 /01 DATE 12.08.00 M24 COMP N0. RECE CTTY OF DWG NO. 9- 101 -M585