Loading...
HomeMy WebLinkAboutPermit M01-077 - SOUTHCENTER MALL - VERIZON WIRELESSSouthcenter Mall EXI:fl ED OCT 2 9 2001 City of TuIila ` (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Address: 622 SOUTHCENTER MALL Location: Parcel #: 262304 -9004 Contractor License No: PACIFCS187PK MECHANICAL PERMIT Permit No: M01 -077 Status: ISSUED Type: B -MECH Issued: 05/01/2001 Category: NRES Expires: 10/28/2001 TENANT VERIZON WIRELESS Phone: 622 SOUTHCENTER MALL, TUKWILA WA 98188 OWNER SOUTHCENTER JOINT VENTURE ATTN: JAMES J GUDIN, 25425 CENTER RIDGE RD, CLEVELAND OH 44145 CONTACT TREACY ROACH Phone: 425 - 455 -3000 2275 116 AV NE, #100, BELLEVUE WA 98004 CONTRACTOR PACIFIC CONSTRUCTION SYS INC 2275 116TH AVE NE STE 100, BELLEVUE WA 980043084 ********************************************* * * * * * * * * * * * * * * * * * * * ** * * * * * * ** Permit Description: I w UMC Edition: 1997 Valuation: .00 0 Total Permit Fee:. 46.50 N w 1 w enter Authoi zed S i gn Lure Date g W W U0 0 H. w Date: S /- 2/ 1— . .. CO OeE This permit shall become null and void if the work is not commenced within Z 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. NEW DUCTWORK, GRILLES.IN RETAIL SPACE. EXISTING UNIT TO REMAIN. * * * * * * * ** *************************** * * * * * * * * ** * ** * * * * * * * * * * * * * * * * ** ereby certify th t I have read and examined this permit and know the sane: to.be true and correct All provisions - of law and ordinances governing this work will be complied with, whether specified herein or .not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I ani authorized to sign for and obtain this :build g permit. Signature: Print Name:_ � j 4//7 '- Title: Complete F7` vnxouT[.00c 5149 PLAN REVIEW /ROUTING SLIP TIVITY NUMBER M01 -077 DATE: 4 -25 -01 PROJECT NAME: VERIZON WIRELESS SITE ADDRESS: 622 SOUTHCENTER MALL #620 SUITE NO: Response to Incomplete Letter # Original Plan Submittal Response to Correction Letter # • Revision # AFTER Permit Is Issued DEPARTMENTS: Build9ng Division Fire Prevention AWC 4 4 4 -0 1 4 6- 11 - oI Public Works n Structural APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions )(„ Isf;40) Planning Division n Permit Coordinator n • DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 4-26-2001 Incomplete n Not Applicable TUES /THURS ROU NG: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: Comments: PERMIT COORD COPY DATE: DUE DATE 05 -22 -2001 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions n Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: 1 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER M01 -077 DATE: 4 -25 -01 PROJECT NAME: VERIZON WIRELESS SITE ADDRESS: 622 SOUTHCENTER MALL #620 SUITE NO Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # ` AFTER Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) n Complete Incomplete n Not Applicable Comments: TUES /THURS ROUTI G: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: Structural APPROVALS OR CORRECTIONS: (ten days) Approved C Approved with Conditions REVIEWER'S INITIALS: VYINOU1I.DOC srr� Fire Prevention n Planning Division Permit Coordinator n DUE DATE: 4- 26-2001 DUE DATE 05-22 -2001 Not Approved (attach comments) n DATE: 4 CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions n Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: oc ILU U CO o cn W O; cog ' : 0; w O`. • UJ U w w �. O Z V u)' 0 - Z PERMIT NO.: Mb t 0 froll MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 00002 Pre - construction ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation /Indoor AQC ❑ 00610 Chimney Installation /All Types ❑ 00700 Framing ❑ 01080 Woodstove 01090 Smoke Detector Shut Off 01100 Rough -in Mechanical 01101 Mechanical Equipment/Controls ❑ 01102 Mechanical Pip /Duct Insul ❑ 01105 Underground Mech Rough -in ❑ 01115 Motor Inspection 1400 Fire Final 01800 Final Mechanical ❑ 04015 Special -Smoke Control System CONDITIONS 0001 No changes to plans unless approved by Bldg Div ❑ 0014 Readily accessible access to roof mounted equipment 0016 Exposed insulation backing material 0019 All construction to be done in conformance w /approved plans ❑ 0002 Plumbing permits shall be obtained through King Co 0027 Validity of Permit 0003 Electrical permits obtained through L & I 0036 Manufacturers installation instructions required on site "BTU maximum allowed per 1997 WA State Energy Code" 0041 Ventilation is required for all new rooms & spaces 0005 All permits, insp records & approved plans available "Fuel burning appliances "Appliances, which generate...." ❑ "Water heater shall be anchored...." Additional Conditions: TENANT NAME:_ y PT V j Val US FEES •=•tvikkethi% Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace /Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall /Floor- mounted Heater (qty) Appliance Vent (qty) Heating/Refrig /Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) Add'l Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'l Plan Review (hrs) Plan Reviewer Date: Permit Tech: d V ( Date: ::ACTIVITY NUMBER M01 -077 DATE: 4 -25 - 01 PROJECT NAME: VERIZON WIRELESS SITE ADDRESS: 622 SOUTHCENTER MALL #620 SUITE NO: Original Plan Submittal Response to Incomplete Letter # Response to Correction. Letter # Revision # AFTER Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 4- 26-2001 Complete n Incomplete n Not Applicable n Comments: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: Approved ❑ WRIlOUfLOOC vri PLAN REVIEW /ROUTING SLIP n CORRECTION DETERMINATION: Fire Prevention Structural ❑ Structural Review Required 5/6 APPROVALS OR CORRECTIONS: (ten days) Planning Division n Permit Coordinator No further Review Required IX1 9 f 6 ) DATE: DUE DATE 05-22 -2001 Approved ❑ Approved with Conditions n Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: DUE DATE Approved with Conditions n Not Approved (attach comments) n n REVIEWER'S INITIALS: DATE: er :mo W O. U. Q. s2 a DJ ail O N oI- w w .: V O Z' V w O Project Name/Tenant: v?4(1 7 �'Y. U1I/tre — i� 4/6.0 Value of Mechanical Equipment: c" p-) / iet..) C �{ Site Address : City State/Zip: Site 2 -- Metee C, '7t•kwr Ic r r ' 1 Tax Parcel Number: RY ,�4 4.... Prop O ner: e , j „CG /n Phone: ( ' / (i d r y ' /g-0z Stre r 42. ' ( we/16e 1 `�' t ` - vela OCI.Ay ( W is _ Fax #: (it ) �0 I Cont t tG� -6'1 G Phone: ( GJ I ^ 31�� � horodi, :71-€4 f €4 poach, Street dd re � 1 l ty S Zi : A e os 4 #t. edeotive Ci wSA / ���g� Fax #: ( etZ yet 2 2 62, Contact Prison: n Phone: ( - , 2.5 1._ `l Street Addr S t a i t 1( 66` 1 A- -e vi .._4.)06 a ?e I, uve City i 4 cc1 ) Fax #: ( (9coa — g 2 6y , r , �`Bf�ItDlNG O v „ ,• `ER;OR�A'tJ�rHORIZED�At; ... 1 , i,:.:!,,, , „, ti.:,.; I �r t „.i: ,,• t r ,� h. {�t; v� 't• �'' .F �, .• � ' 1' ,!:1.:,' , . r Pi. F •J�f. Signature: 1 -(A L Date: e Q Print n Phone: ( Fax #: ,,,,.06) ) Addr�; bi9 - 2 Q City /S Z i • qd i 'f ,r,,,, CITY OF ; .'KWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 ' STAFF USE ONLY ' Project:Nirniber. Permit Number, 6 1 7 Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. .R, INECHANICAL:PE.RMIT REVIEW AND`rAPPROVAL `REQUESTED :'(TO BE'F /LLED OUTBYi4PP.L►CAIVT) Description of work to be done (please be specific): -ems elArlfente v1/7 6 ( 511 vv.o pt- - i-e3 if\gV\A.AA^A WA/1/ A■() T A5fdL(,ID L-C- - Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the . permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date application accepted: Date application expires: 11/2/99 reeds penulf.rloc �T /� vaNaer -O/ Al v ors RECEIVED CITY OF • APR 2 5 20U PERMIT GEt. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Application taken by: (initials) ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 • H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other a•.licable re•uirements of the Washin :ton State Nonresidential Ener: Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. ESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications. Charge - out or replacement of existing mechanical equipment Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If, using existing chimney, provide a letter by a certified chimney sweep stating that the condition. chimney is in safe NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please heaters or vents being installed or replaced. Wilse include any water .aN,uu:,>rY.i�r Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal 11/2/99 nilscpml.doc NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. I', �t tltvlM CITY OF TUKWILA' .- .L , .. , ::.404reSs:' , 622 '5OUTHCENTER MALL 54..iite.' Tenant.: WIRELESS Status: - ISSUED Type: . B-MECI-1 . i : ApPlied: 04/25/2001 • .: • • -1-1,, ':-rarcel.41 4.b4...,04-0004 - Issued: 05/01/2001 .- „4,4 f 4,.*4, ,, k 4 •0'; * A 14 * '1 4 44 : k 41 ** lc *lc 14* *It.* * lc A ek *lc . k.04 ***le f ck• ¼ le* 'At* * - 0 ! i .k .A. 1 e *1 r .4( 'Vklt A**** A *** A le.*** P e r m i t Con d I t i ons :-: : : - . ; 1 . . ; I : E 1 elotrica 1 'permits she 1 1 be obtained through the Washington State tthilsion of : La bor and:In'd ut es . and all e 1 ect r tc:al work. . will be '- (24C-6G30) . • -No changes . w 11 1,...,66:Alia tp the p unless , by the . , ,-„, -,. Eng i neer .and,..Mferf'.iiikyiii. Bu .0 d i n : q . , D i v is ion 2 Al . 1 '1)e r in 1 t: ;: e p t'i..,Ori..records :i ':.' and apPFPveii'PAans sha 11 be aki i 1 ab 1 etiFthe : i o b site prior to the , : , . t . A 1 7 , t o f :any '. S 0~0 O t i o i t , : ' - f , ' " . T h e e . .q.:(10Ou M e n t s-e a re . t ci be maintained a hda ' V a i 1 - able tiptill f,tne 1 : ' , . . i n s p e o f fon approval ' - ' : I s . granted.... ■:: . i:. All : orf'' to , _ , Ibe ' don e\,.,t so nf o rma ri Op, w ith .':. a 0 p raV.Oiti . .;. : P1 a its'i4n d ' i-e $6:I reiont:::: of the 1:40-,f Om Bu i 1 d i nti' (19917 • . Ed amended : • , ' , . , L i r t l . , , : t t o O n Me can i ca 1 Code' i ejOn ) .,. , •-• - ., ,•.eriWas tfi,trig t On TS t e te,:•,En e rgS .. Code (1997 ' Ed i t i on), i atiX1 it -f, .P,er, mi t .: The i 1 ' of a permit Or a pr7Ovi PI'a9s .f.: oat i 06'S;-. and.F,:compatit ions shai 1 not be strued =:- :a . perhi,t, 'fbr ' . 0 r a w,...,a p_prp v a 1 of. an 4 v10.3 tt i dii' OkVeriy of I the provisions O'f . c.the , 440 1 ci'cria code or of 411*.:,• other r Ord i n a r.7., e st the „jun i salet IO n .." ..,-- No erm i t D re Sism i no tol . ..--., • .16 ,_ i...,! . v , , . 4„ e !a titborl tiY ['tO... 0 ra e:4 ,,str canOe F::./t11e. i s i ons of 't, 61 s 1 '. ee;:di• .t 431 1. I? e., el i d:./ i.: \''.. J' 'f ./ ". - 7, "...y'riiiii7itif*;,tu rers 111.S.tayl til on''.'..'ins i on s „.i're q 0 i re d On s i t es, i: •:•-.- ' '-, icke;;: the . bkti 1 d i ng ev iefir„ Perini t No: M01-077 ,...c.c.,• ,,,, . . ,.- - . ..• erekiVN0404 'Alava read...Wesc,..piiditi anl wilr v:pk, . :„...... e ., .101 ,:. t a s0' 60 tfr1 in e d .: : A1.1 pr-ov i s,i',,oii s of c 1 , a ,n d: o r di n a p O6'.E. over i) i rig h 1. wo1 -4.-'.: 4 4 : \ will he •;.•OntO 1 i ed w i t h . w tie tlyer '',::1-le'0f s ie;d ti:0, r e 1 r r.. 9y,,, 7 .. h 0 9ren t,S.9 of ': this P'eripi,t does r peesu1ikejto .-'91,ire au hor it v: t 1■:Y1a tir t.. - Ooy s ii s i on s: Of any other 40 ill: on-.1oca,lc:'?1;aws .r."egiiT6 ti il T. ' rtietl on a : i" . .-;'. ,)e perf o rola n c e Of '''wori; , .• :::,:.• -: •.-'.' : .. .: NI .; f., "6' '.':,,,,:-,, : ' , . ' c' ):, 0 ., ,,, , , . . . , . • • 1 t (.1 "f ‘‘ htve40;4•F * A * ••*`1,1**ir ** "V •Ir * * * 11—* -:te* * * * 4i* * * :1; * * .** :iC* * * * ; IV * I11 r ;TO is • 4„ . 4c **********A4** n R01 f".! 6101 .46 - 05/01,101• cyt ion PAC C. CONS D LICENSE DETAIL INFORMATION Form STATE OF WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES Specialty Compliance Services Division P. O. Box 44000 Olympia, WA 98504 -4000 THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS: LICENSE DETAIL INFORMATION Current Filter: None Registration# or License PACIFCS187PK Name PACIFIC CONSTRUCTION SYS INC Address 2275 116TH AVE NE STE 100 Address City BELLEVUE State WA Zip 980043084 Phone Number 4254553000 Effective Date 10/12/82 Expiration Date 10/1/01 Registration Status ACTIVE Type CONSTRUCTION CONTRACTOR Entity CORPORATION Specialty Code GENERAL Other Specialties UBI Number 600442182 * * *VIEW PRINCIPAL OWNER(S) FOR THIS LICENSE* * * *VIEW CONTRACTOR BOND /SAVINGS INFORMATION * * * * * *CHECK INQUIRY FOR SUMMONS AND COMPLAINTS* * * * * *VIEW CONTRACTOR INSURANCE INFORMATION * * * New inquiry by CITY, NAME, PRINCIPAL OWNER NAME, NUMBER, UBI NUMBER or return to the L &I Construction Compliance Home Page http: / /www.lni.wa.gov/ contractors /TF2Form.asp ?License= PACIFCS 187PK 4/30/01 October 1, 2001 Ms. Treacy Roach 2275 116th Ave. NE, #100 Bellevue, WA 98004 City of Tukwila Department of Community Development Steve Lancaster, Director RE: Permit Application No. M01 -077. Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to schedule a progress / final inspection A progress inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to 10/28/01, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Kathryn A. Stetson Permit Technician Xc: pe�rnit:FileNo.M01- 027 Duane Griffin, Building Official Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206 -431 -3665 00 U11 V Q : N ' W O } ; . J ;• V. d ;. z p LU Ni :. 0 1—• . W W' — O. ai = . O H z . NOTICE IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE %T IS DUE TO THE QUALITY OF THE DOCUMENT. ELECTRICAL FIXTURE SCHEDULE TYPE SYMBOL ITEM MANUFACTURER MODEL ORDERING INFORMATION COMMENTS L -1 Formica, " #892 -68 Folketane Celesta' 2 X 4 UTHONIA 230' PARABOLIC TROFFER 2PM9N Q B 3 32 18LS 120 GEB1G LAMP: 32 W13 (487 �` ❑' 2 X 2 UTHONIA 272 PARABOUC TROFFER 2PM3N G B 3 17 9L.S 120 GEBIO LAMP: 32 WTB (241 B ® 2 X 4 LITHONIA 231.4' PARABOLIC TROFFER 2PM3N G B 332 18LS 120 GEBIO EL LAMP: 32 WTB (481 BB IN 2 X 2 LTTHONIA 2'(2PARABOUC TROFFER 2PM3N 0 B 317 BLS 120 GEB10 EL LAMP: 32 WTB (241 C ® 2 X 4 LTTHONIA ACRYUC 2'X 4' 2SP3 332 FW Al2 120 GEBIO LAMP: 32 WTB (4W) CC' 0 2 X 2 WHOM ACRYLIC 2' X 2' 2SPG 317 FW Al2 120 GEB1O TAMP: 92 WTB (48 D ®'.,. 2 X 4 UTHONIA ACRYLIC 2'X 4' 2SPG 3 92 FW Al2 120 GEB1O EL LAMP:92 WT8 (481 DD 0 2 X 2 U1HON1A ACRYLIC 2 X 2 2SPG 3 17 FW 112 120 38810 EL LAMP 32 WTB #1r) E'... 0 4" RECESSED LRHONIA DLV SERIES DLV WSH MRI8 4AC 120 LAMP: 75W MR16 FL F O. 4' RECFRRFTY LfiHONIA DLV SERIES DIV DWN MRIB 4AC 120 LAMP:75W MRI8 FL G' ®' EXIT SIGN LIIHONIA OIJANTUM LED QUICK MWM LELM SW IR 120277 EW ARROW DENOTES DIRECTIONAL H BR FIXTURE L13.46'- VB4PAI2XYBK :. SUPPUhD BY VERIZON WIRELESS INSTALLED BY CONTRACTOR FIXTURE PWGS INTO 1" HI OUTLETS IN RETAIL SALES I I K - G- EXIT SIGN (FngF 1 TO MONK PRECISE FWORESCENT SERIES F2RP 1 RC 120277 0. N N TRACK FIXTURE HALO HEADS: L1738 MB TRACK 650 SERIES MB HEADS: L1738 MB TRACK 850. SERIES MB (SEE GEN. NOTES) LAMP: 75W PAR38; (# DENOTES LENGTH OF ,TRACK) P A A TRACK FIXTURE BRUCK LIGHTING HEADS: TAKATO 330 TRACK: FLEX -UNE HEADS: TAKATO 330 TRACK: FLp( -UNE (SEE GEN. NOTES) LAMP: 50W MR16; (# DENOTES LENGTH OF TRACK) Q 0 8' MOBBED HALO C8528•.8551 C8526 IE 8551 Li FLOORING _ WALLS 8 CEILING FINISHES MISCELLANEOUS - 11‘ plans do Ddoptod 0-1 Milliken Carpet Tile - 38" x 38" Blue Thatch- Paitem# 546117 Color #6; DR# E3138340 -00. Supplied by Vedwrr Wireless; C4xxdlneted end Installed by Contractor P-2 ShenvIn-WMIams #SW1003 'First Star', Satln For use on door only: Pro- Classic Interior Alkyd Seml -Gloss 834 Series L -1 Formica, " #892 -68 Folketane Celesta' tractor's L-3 Formic8'299 -58 Ebony Oxide" - 0 -1 0(088 le Ceramics, Cross Colors Series. 5.12' x Finish: Unglazed Supplied end Installed by Contactor , P-9 Sherwin -Mems, 'V - In Blue, Eggshell' Sherwhi-'MWarn Nlm,R er Red' L-4 L-4 : Formica. •#909 Black" , FormIca� #1782 -58 Stardust' try •R4 Sher in- WlWams BSW1008 'Slihoud[8'. SemFGto88 'Fe use on door only? , ' Interlorakyd Semi-Glose B34 series L-8 ABETi M829 SEI DatE T-2 American Man 'SeagullGrayl #43',4 V4" x 4 V4", Glazed - Ceramb C o v e Base the ' Supplied and Installed by Contractor � 7 l Formica. '4851-68 Spectrum Blue" Perr P -6 Sherwle-wstams #SWI007 '131�k T H' , Rat '.. All cabinet nterlora to be white melamine, except at;Sales and Service Desks, which shell be as noted on all F drawings. All cabinets shall have 4'vrire pull hardware with brush chrome flnleh. T-3 American Olean "Sterling Sliver #132", 2' x 2", Unglazed Ceramic Mosaic Supplied and Installed by Contractor wc=i KorpsealVyalkx>tadngs Pattern - Mocha LaBe; Die# L315; Pattern Color 580 Supplied by Verizon Wireless; Installed by Contractor. Contact Stephanie 818W{93- 0412 'Black Galaxy (Black with silver mica fleck appearance) Supplied land Installed by Contractor. GR-1. Floor grout shall be Laticrete, sanded floor grout #45 French Gray with #1776 (1-1) Grout Admbwre and Miracle Sealer #511 or Equal. Supplied and Install ed by Contractor AT -1 °e ne; C olo( 1Y A Flo appearance; Haze Lodi #1780 Huh 24' x 48' X 3'4' Gdd: 15 Prelude Exposed Tee; eolorto match tlle. VT-1 Tadmd, #2020 Refined White Multi . Supplied and. Installed by Contractor. C le altar on. aIVactOr efle8 seal aand wax all new Mnyltl a _ .... ... �gy9g ®I2O����° REVISION d SHALL .LL E - MAC TO . ' O r A C V, ti K WITHOUT Pr ` A C' TJICWILA BUILDING DIVI ° L..�7 PTV iT :CLUD �:RS wNLL EA00f R A Now P E A1. PLAN R` - LAN FEE., r:) Y AT-2 " + x 5 Armstrong " Cortege #769 White, 24 x 48 Color White. Grid:15.1W Prelude Exposed Tee; color to match tile. Johns0nite #40 Biadk,4' cove. B-2 JOhnsonite #37 Fog.4" . owe. MTL-1 18 GA 'PRE-VANDALIZED', PRISMATIC #304 STAINLESS STEEL REFERENCE SYMBOLS SCOPE OF WORK TENANT IMPROVEMENT WORK IN AN EXISTING ONE STORY COVERED MALL BUILDING INCWDES THE INSTALLATION OF NON - STRUCTURAL PAR3830N WALLS, UGHT FIXTURES AND FINISHES. GENERAL NOTES 1. DO NOT SCALE THE DRAWINGS. 2. VERIFY FIELD CONDTRONS PRIOR TO COMMENCEMENT OF EACH PORTION OF THE WORK 3. THE CONTRACT DOCUMENTS ARE'COMPUMENTARY, AND WHAT IS REQUIRED BY ONE SHALL BE BINDING AS IF REQUIRED BY ALL; THE CONTRACTOR. SHALL COORDINATE TO COMPLETE THE WORK NOTIFY THE ARCHITECT FOR RESOLUTION OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. PROJECT DIRECTORY ABBREVIATIONS A ANGLE AT a 8 CENTERLINE L CHANNEL 0 PENNY PERPE NDICULAR 4 POUND OR NUMBER 0 DIAMETER 11 SQUARE FEET A.B. ANCHOR BOLT A/C AIR CONDITIONING ACOUS. ACOUSTICAL AC.T. ACOUSTIC TILE A.D. AREA DRAN ADD. ADDENDUM ADJ. ADJACENT ADJUS. ADJUSTABLE A.F.F. - ABOVE FNSN FLOOR AGGR. AGGREGATE ALT. ALTERNATE AL.. ALUM. ALUMINUM ANOD. ANODIZED APPROX. APPROXIMATE ARCH. ARCHITECT ASPH. ASPHALT 8D. BET. BLDG. BLK. BLKG. BM. B.M. BOO. BR. BRZ. B.U. CAB. C.B. OEM. CER. C.G. CHAIMF. C.I. C.I.P. CRC. C.JT. CLG. CLR. C.M.U. CNTR. C.O. COL. CONC. CONN. CONST. CONT. CONTR. CORR. CPT. CSMT. C.T. CTR. CSK. CU. FT. CU. YD. DEMO. DBL. D.L. GET. D.F. D.H. DIAL. DRAM. DIM. DIV. DN. DP. DPR. DR. DS. D.T. DWG. DAR. (E) E. E.JT. EL. ELEC. ELEV. EN EQUIP. ESC. EST. EXCAV. EXH. EXIST. EXP. EXT. F.B.O.I.C. F.0.1.0. F.D. FDN. F.E. F.E.C. F.F. FIN. FLR. FLASH. FLUOR. F.O.S. F.O.C. F.O.F. F.O.S. M. F.O. fP. FT, FTG. FURR. FUT. F.R.G. F.W.C. GA GA.V. G.B. GEN. GL. GND. GR. C.W.B. GYP. GFRC. H.B. H.C. HD. HDBD. HDCP. HER. HDWR. H.M. HOR2. HR. HT. HTG. H.V.A.C. H.W.H. D. P.S. NCL. NSUL. T. V. BOARD BETWEEN BUILDING BLOCK BLOCKING BEAM BENCH MARK BOTTOM 8E44400 BRONZE BASEMENT BUILT UP CABINET CATCH BASIN CEMENT CERAMIC CORNER GUARD CHAMFER CAST IRON CAST- IN- PLACE(CONCRETE) CIRCLE CONTROL JOINT CEILING CLEARLANCE) CONCRETE MASONRYUNIT COUNTER CLEAN OUT COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CONTRACTOR CORRIDOR CARPET CASEMENT CERAMIC TILE CENTER COUNTER SINK CUBIC FOOT CUBIC YARD DEMOLITION DOUBLE DEAD LOAD DETAIL DRINKING FOUNTAIN DOUBLE HUNG DIAGONAL DIAMETER DIMENSION DIVISION DOWN DAMPPROOFING DISPENSER DOOR DOWNSPOUT DRAIN TILE DRAWING DRAWER EXISTING EACH EXPANSION JOINT ELEVATION ELECTRIC(AL>. ELEVATOR ENCLOSE(URE) EQUAL EQUIPMENT ESCALATOR ESTIMATE EXCAVATE EXHAUST EXISTING EXPANSION EXTERIOR FURNISHED BY OWNER INSTALLED BYCONTRACTOR FURNISHED BY OWNE INSTALLED BY OWNER FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTNGUISHERCABINET FACTORY FLASH FINISH(ED) FLOOR FLASHING FLUORESCENT FACE OF STUDS FACE OF CONCRETE FACE OF FINISH FACE OF BRICK FACE OF MASONRY FIREPROOF FOOT. FEET FOOTING FURRED, FURRING FUTURE FIBERGLASS REINF. GYPSUM FABRIC WALLCOVERING GAGE GALVANIZED GRAB BAR GENERAL GLASS, GLAZING GROUND GRADE, GRADING GYPSUM WALL BOARD GYPSUM G. ASS FIBER REEF. CONC. HOSE 81BB HOLLOW CORE HE HARDBOARD HANDICAPPED HEADER HARDWOOD HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING HEATING /VENTILATING/ AIR CONDITIONING HOT WATER HEATER INSIDE DIAMETER INSIDE PIPE SIZE INCLUDING INSULATION INTERIOR INVERT JAN. JST. JT. KIT. K0. KPL. O.A. 0.C. 0.0. O.F.R.D. OH. OPP.H. OPNG. OPP. 0.T.S. PASS. P.B. P.BD. PERF. PERI. PL. P.L. P. LAM. PLAS. PLO. PNL. PR. P.S.F. P.S.I. PT. P.T. P0. PTN. PVMT. P.T.D. P.T.R. Q.T. R. R.A. RAD. R.B. R.T. R.D. REF. REFL. REFR. REG. REINF. REQ. REV. R.H. RM. R.O. R.O.W. RCP. S. S.C. SCH. S.O. SEAL. SECT. S.F. SH, SHT. SHTG. SIN. SL. 53110.0. SPEC. SQ. S.S. S.STL. STD. STL. STIR. STR. STRUCT. SUSP. T. T.B. TEL. TEMP. TERR. TEX. 3.40. THK. THRESH. T.JT. TKBD. 1.0.8. TV. TYP. TOS. T.T. DPR. UNFIN. U.O.N. VAR. VEN. VERT. VEST. V.G. V.W.C. W. W/ W.C. WD. W.H. W/O WP. W.R. W5CT. WT. WAR JANITOR JOIST JOINT KITCHEN KNOCKOUT KICKPLATE LAM. LAMINATE(0) LAV. LAVATORY L.H. LEFT HAND LENGTH LONG L. L. LIVE LdAD LT. LIGHT LPL. LINTEL LVR. LOUVER RE MRS.. MASONRY MAX. MAXIMUM M.C. MEDICINE CABINET MECH. MECHANICAL) MED. MEDIUM MEMB. MEMBRANE MET. METAL MEZZ. MEZZANINE MFR. MANUFACTURER) M.F.B. MINERAL FIBER BD. MH. MANHOLE MIN. MINIMUM MISC. MISCELLANEOUS 910. MOUNTED MTL. MATERIAL MULL. MULLION N. N.I.C. NOT T !N CONTRACT NO. N NOM. NOMINAL N.T.S. NOT TO SCALE OVERALL ON CENTER OUTSIDE DIAMETER OVERFLOW ROOF ORAN OVERHEAD OPPOSITE HAND OPENING OPPOSITE OPEN TO STRUCTURE PASSENGER PANIC BAR PARTICLE BOARD PERFORATE(D1 PERIMETER PLATE PROPERTY LINE PLASTIC LAMINATE PLASTER PLYWOOD PANEL POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POINT PRESSURE TREATED PLANTER DRAIN PARTITION PAVEMENT PAPER TOWEL DISPENSER PAPER TOWEL RECEPTICAL QUARRY TILE RISER RETURN AR RADIUS RESILIENT BASE RESILIENT 11LE ROOF DRAIN REFERENCE REFLECTED REFRIGERATOR REGISTER REINFORCING REQUIRED REVISION RIGHT HAND ROOM ROUGH OPENING RIGHT OF WAY REFLECTED CLG. PLAN SOUTH SOLID CORE SCHEDULE STORM DRAIN SEALANT SECTION SQUARE FEET SHELF SHEET SHEATHING SIMILAR SLOPE START OF CURVE STAND PIPE SPECIFICATION SQUARE SERVICE SINK STANLESS STEEL STANDARD STEEL STORAGE STRUCTURAL STRUCTURAL SUSPENDED TREAD TOWEL BAR TELEPHONE TEMPERED TERRAZZO TEXTURE(D) TONGUE AND GROOVE THICKNESS) THRESHOLD TOOLED JOINT TACKBOARD TOP OF BRICK TELEVISION TYPICAL TOP OF SLAB TOILET TISSUE DISPENSER UNFINISHED UNLESS OTHERWISE NOTED VARNISH VENEER VERTICAL VESTIBULE VISION GRILLE VINYL WALL COVERING WEST , WIDE WITH WATER CLOSE1 WATER HYDRANT WITHOUT WATERPROOFING) WATER RESISTANT WAINSCOT WEIGHT WELDED WIRE FABRIC STRUCTURAL GRID UNE DETAIL NUMBER (OR LETTER) DETAIL �J� DRAWING SHEET NUMBER SECTION NUMBER (OR LETTER) WALL SECTION DRAWING SHEET NUMBER SECTION DESIGNATION (OR LETTER) BUILDING SECTION • DRAWING SHEET NUMBER DATUM ELEVATION FLOOR PLANS PARrmON TYPES DOOR NUMBER -- `LJaJ' HC DOOR TYPE SPECIR110NB PEgFlCATI0N5 SEE DOOR 10PES. SHEET A0.00 ROOM NEW PARTITIONS INIEROR ELEVATOR FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET SPRINIO.ER 04L88 0.008 DRAIN REVISION NORTH MATCH UNE ROOM NAME 1 202 REFERENCE TO DIM POINT REFLECTED CEILING PLANS 9 FEO DRAWING NUMBER ELEVATION NAME UMBER. 2 x 2 2 x 4 x FLUOR 3CM' Q ®. fTR(TURE WALL MOUNTED FLORESCENT PCC LIRE OOWNUGHT r 0 WALL WASHER e WALL MOUNTED 2 CEILING MNTD. WALL MNTD. FLUORESCENT Gimp FIXTURE IN LIGHT COVE EXIT SIGN HVAC SUPPLY RETURN EXHNIST WEAR DIFFUSER SPRINKLER HEAD X SMOKE DETECTOR 11.11 ROWER STRIP 1FD SEE TITLE BLOCK FOR REVISION. MOST RECENT REVISION SHOWN CLOUDED..' POWEWCOMMUNICATION PLANS OUP101 ELECTRICAL ouREr DUPLEX ELECTRICAL oXILET, DESIGNATED. .m-r-oES CIRCUIT - COMPUTERS, ORANGE OUTLET. SEE COMPUre5 EQUIPMENT SCHEDULE � SIMPLER( ELECTRICAL OUTLET, DESIGNATED 0 8 CIRCUIT -1 COMPUTERS. ORANGE OUTLE1.. SEE q, comm. EOIPMEN1 SCHEDULE, eF DUPLEX ELECTRICAL OUTLET Wlili TIMER. pp PLUG -81R1P 084 DEWCA1ED OUTLETS 7Y DH RPLF0 EIF ED CIRICRL 005ET, DEDICATED fir .:IRCUIT WITH ISOLATED GROUND. Ee DUPLEX ELECTRICAL OUTLET, DEDICATED CIRCUIT. /jT1 ( g4 , ED 9 PLUG STRIP YU4 DEDICATE OUTLETS FOURPLEX ELECTRICAL RET, DESIGNATED aE CIRCUIT - COM PUTE T O0 OH EDXI OUnETS. SEE 8 COMPUTER EQUIPMENT SCHEDULE. TELEPHONE MUDNNG AND PULL- SIRING. a - COMPUTER MUDRING AND PULL-STRING. 414 81NGLE GANG BOX W/4 001488ONE JACKS DUPLIX ELECTRICAL OUn.ET, GROUND FAULT oes D.F. C.IOIROUIT I NfER RUP IEIL xi UNDER FLOOR DUCT FLUSH WITH CONCRETE FLOOR 1 SLAB. OUTLETS SPACED AS SHOWN. PROVIDE POWER INDICATE.TYP. COMMUNICATIONS CABLE AND JACK BY OWNER. L 1� EIECTmCAL JUNCTION BOX - SEE exam. FLUSH mM858. 4 p FLUSH MOUNTED FLOOR MONUMENT W1H �'C7 SERVICE INDICATED OWNER'1ENANr: VERIZON WIRELESS CORPORATE PROPERTIES GROUP 3600 136TH' PLACE SE BELLEVUE,WA 98008 ARCHITECT: ORISON ARCHITECTURE INC. 1420 FIFTH AVENUE SURE #2400 SEATTLE, WA 98101 (206)623.4818 CONTACT: MARTIN HILL MECHANICAL CONTRACTOR: PROJECT ADDRESS: DALE SCHNACKSL COMPANY CONSULTING ENGINEERS OF OMAHA 3035 SOUTH 72ND STREET SURE 101 OMAHA, NEBRASKA 68124-3584 CONTACT: GREG SCHNACKEL PACIFIC CONSTRUCTION SYSTEMS, INC. 2275 116TH AV NE #100 BEL EAUE WA 98004 -3084 VERRON - SOUTH CENTER MALL 622 SOUTH CENTER MALL #F-620 TUCKWILIA, WA 88188 FINISH SCHEDULE VICINITY MAP PROJECT SRE DOOR SCHEDULE TYPE Al -1 3/4'XS'-0"AT -0' 5000 CORE WOOD DOOR WITH HOLLOW METAL FRAME PAINT P-2 TYPE Cl 5 "DX7'- O1HX3 -0'W GYPSUM OPENING. NORTH DRAWING N.T.S. TYPE 81 12 7 THICK, CLEAR, TEMPERED' SLIDING GLASS DOORS IN BRUSHED CHROME FRAME AT TOP AN0BOTTOM W(TH'BRUSHED CHROME FLUSH PULLS. 5EE', ELEVATION KEY PLAN SEARS PROJECT SRE BUILDING USE: COMMERCIAL OCCUPANCY GROUP: M CONSTRUCTION TYPE: TYPE V-N RATE RAINFOREST TUPPERWARE I I MALL CONCOURSE BUILDING CLASSIFICATION APPUCABLE CODE: 1997 UBC TENANT IMPROVEMENT AREA AND OCCUPANT LOAD, CALCULATIONS: TENTAN1 IMPROVEMENT AREA:2203 SF /30 SF PER 'OCCUPANT = 74 OCCUPANTS TOTAL 2200 SF 74 OCCUPANTS EXITS REQUIRED:'' TWO EXITS WHEN OCCUPANT LOAD IS GREATER THAN 50 OCCUPANTS (TABLE 10-P( EXITS PROVIDED:' TWO EXITS (TWO. ACCESSIBLE EXITS) 1 INDEX OF DRAWINGS A0.00. A2.00 A2.01 A2.02 A2.03 A3.01 A8.01 A8.02 A8.03 MI .5 00'3.0 1 El•oc e2-.01 ARCHITECTURAL: CALUSON GENERAL INFORMATION FLOOR DEMOLITION PLAN AND REFLECTED CEIUNG DEMOLITION PLAN FLOOR PLAN AND POWER. & COMMUNICATIONS PLAN REFLECTED CEIUNG PLAN AND .SOFFIT PLAN FINISH PLAN AND FURNITURE' -. & EQUIPMENT PLAN SEC1I08 AND ELEVATIONS CASEWORK DETAILS SALES POD DETAILS DETAILS AR.E1NAh;L kL DLA/J5 0101 0/A21 %`� SoIHe1)1L0 C -LEc IC Ac 0.41- Ux SWITCHPLATE ''DIAGRAM I 3 1 101 1 VISION A SUNGLASS HUT 1 1 BIAGIO SWITCHES TYPE OF UGHT ,�.i 00000 Valia FILE COPY NORTH DRAWING N.T.S. DIMMER SWITCHES TYPE OF UGHT CIRCUIT I understand that the Plan Check approvals are subject to errors and omissions and approval of s not authorize the violation of any ode or ordinance. Receipt of can- opy of approved plans acknowledged SEPARATE PERMIT REQUIRED FOR: 0 MECHANICAL KELECTRICAL PLUMi3iM0 d GAS 1 CITY of „ TUIfiNIL.A BUIL-044d L`NI$10N • ISSUED I REVISED PERMIT ISSUE PERMIT ISSUE APRIL 23, 2001 az z O W N CO 0 U- (0 -J -I Q F- W W F W Z W z U W U I- I- 0 0 DATE 4/23/01 GENERAL INFORMATION APR 2 5 NO] A ^PERMIT CENTER LEGEND EXISTING NEW WORK NEW TO EXISTING CONNEC77ON is !MEWL AD7ES 1. EXISTING commons ARE BASED LIMITED FIELD VERIFICATION. CONTRACTOR SHALL AD.A,$T TO ACTUAL FIELD CONDITIONS AT NO ACOITIOVAL &GREASE 70 771E OWNER. 2. LYWTRACTO4 SHALL FAMILIARIZE HIMSELF WI7H DEMOLITION YERK PRIOR TO BIDDING AND START OF MON. 'CONTRACTOR IS IESPCRSIBLE TO DEMOLISH ALL EXISTING AS REWIRED FOR INSTALLATION/CONSTRUCTION OF AEW WORK. 3. AECHANICAL aWTRAC77)R SHALL FIELD COORDINATE 17771 ELECTRICAL OCN71ACTOR FOR ALL POWER IEc1QREAENIS. 4. COORDINATE DLCT RCXIIIAC AAD !EIGHTS tI7H GL'-TERAL CONTRACTOR. VERIFY ALL CXEARAAKES BEFORE STARTING WORK. 5. 17E CONTRACTOR SHALL OBTAIN A COPY OF 77E LAADLO4°'S 7ENANT CRITERIA A1AAId4L. TENANT ORIIERIA MANUAL REOUIRgENTS SHALL BE INXLC D IN 71115 CONTRACT. CONTRACT STALL BE RESPONSIBLE FOR COPLYIAG 17771 LAA47LORD REOUIREVENTS AT NO EXORA COST TO 77E 7ENAN7: 6. COV7RACICR STALL RESPONSIBLE FOR FIELD VERIFICATION CF ALL EXISTING 4YAIDITIOVS PRIOR TO SUBAHTTING HIS BID. NO ADDITIONAL COIPEASATIOV WILL BE MADE FOR ANY EXTRAS DIE TO CONTRACTOR'S FAILUE TO VISIT 77E ,.Y.BSI7E AAD /OR HREDEJERMIAE ALL EXISTING OOIDITIONS 85 SUBMITTING HIS BID. ANY DISCREPANCIES STALL BE IM ONA7ELY REPORTED 70 77E ETGIAE7R FUR RESOLUTION. 7. ALL WORK ShALL BE OCMPLETED IN ACCOFDAACE IVI7H ALL APPLICABLE COVER/ VT AAD LOCAL OODES. H. V. A.C. AD7E3: 1. EXISTING BLOND? COIL AAD FEAT PLOP ON ROOF TO REMAIN. BALAACE 7O 2000 LFM. 2. EXISTING DUCT /EATER TO REMAIN. 2 H.V.A.C. PLAN SCALE: 1/4" = 1' - MANAGER 106 0 PLUMBING PLAN SCALE 1 /e = 1' -O" PLLIBIAG AD7E2 1. 1/2' VALVED COLD WATER DOWN TO IC.EMAKER AT REFRIGRAla4. 2. CO ECT AEW PIPING TO EXISTING PIPING OF EQUAL 0? CREAM? SIZES. VERIFY LOCATION OF EXISTING PIPING PRIOR TO COA57ROCTIOV 3 SPACE RESERVED FOR ELECTRICAL EQUIPMENT. NO IEJY PIPIAC SHALL CROSS THIS AREA WITHIN THE BUILDIAG 4. WATER /EATER (H1 1). AN7 EXPANSION TAM' (ET-1) MOUWED H ILT/ IN CLILIAC SPACE. PROVIDE DRIP PAN FOR WATER hEA7ER.4AD EXPANSION TAN( (ET -1). PIPE RELIEF 4D DRAIN FROM DRIP PAN 70 EXISTING LALICRY TLS. MAINTAIN A 2' MINIMA/ AIR CAP. 2' 4 8' INVENTORY 1 109 HALLWAY 1 105 L EX /STING LAUNDRY 77/8 70 REMAIN. SANITARY RISER DIAGRAM NO SCALE rvi 0 fr�T7 7 NOTE 2 1/2- 1 108 1/2' ET-1 1/2 r - 3/4 L ;2NOTE NOTE 3 r1 HWH -1 NOTE 4 1 1/2' -4 NOTE 2 I CCI�p W DYED PR 2 7 'L � NO fED skikt COPYRIGHT 72000 CALLISON ARCHITECTURE, INC. z O 411. — CO w w CC Z 0 N CC w oIL co Q Q 70 LL < LLI Lr Z Z H u) CO CV CO ISSUED / REVISED DATE PERMIT ISSUE 04-23-01 PERMIT ISSUE APRIL 23, 2001 MECHANICAL PLANS RECEN =U M 1.00 APP, 2 5 2.001 FERN, CENTER ORY Iii •';KROOM _um - i ! I ► i. 4 .. { MANAGER 1NVEN ■■ ■ ■■ ■ ■■■ f ■ I !' I ! I NOTE 1 ! L I / ■■■ g U ■ 1 L �; �■ RIM I / : ■■ 1 ' • ■ ■■ ■■ 111111 I I 11111111174.211219. . ■ 406 illi Z It1�✓1��1�11i�'+' ga ai�1111 rra � /i� �i►:i � i =i � a IIIN - ��t 1 -x :. ��e �C: i A sm :�C: �° 1 ■� /, _ 2 O _ II I '��� It a i ll, �Ivsnm )•)•u11 >�° tt11 it I 11.11111.9,101 �i • _ I ! s ' �■ i 1 1 11111111111111111 ■■ � �� ' 1 ' 4m 9y +- Elm _,___.„ 111.1.110111 i..... I , 1 1- N f ■■ ■■ ' �� 105 I + - r I S ■i ■■ • I D I I i i i I 1.-Lit 1 I I N I ■1 00-2 .. 4 0 — -�- --- f T- i _T I g l -« , T ! � I C%A N �t'� f i 18/72 ,,, • j" I- I LEGEND EXISTING NEW WORK NEW TO EXISTING CONNEC77ON is !MEWL AD7ES 1. EXISTING commons ARE BASED LIMITED FIELD VERIFICATION. CONTRACTOR SHALL AD.A,$T TO ACTUAL FIELD CONDITIONS AT NO ACOITIOVAL &GREASE 70 771E OWNER. 2. LYWTRACTO4 SHALL FAMILIARIZE HIMSELF WI7H DEMOLITION YERK PRIOR TO BIDDING AND START OF MON. 'CONTRACTOR IS IESPCRSIBLE TO DEMOLISH ALL EXISTING AS REWIRED FOR INSTALLATION/CONSTRUCTION OF AEW WORK. 3. AECHANICAL aWTRAC77)R SHALL FIELD COORDINATE 17771 ELECTRICAL OCN71ACTOR FOR ALL POWER IEc1QREAENIS. 4. COORDINATE DLCT RCXIIIAC AAD !EIGHTS tI7H GL'-TERAL CONTRACTOR. VERIFY ALL CXEARAAKES BEFORE STARTING WORK. 5. 17E CONTRACTOR SHALL OBTAIN A COPY OF 77E LAADLO4°'S 7ENANT CRITERIA A1AAId4L. TENANT ORIIERIA MANUAL REOUIRgENTS SHALL BE INXLC D IN 71115 CONTRACT. CONTRACT STALL BE RESPONSIBLE FOR COPLYIAG 17771 LAA47LORD REOUIREVENTS AT NO EXORA COST TO 77E 7ENAN7: 6. COV7RACICR STALL RESPONSIBLE FOR FIELD VERIFICATION CF ALL EXISTING 4YAIDITIOVS PRIOR TO SUBAHTTING HIS BID. NO ADDITIONAL COIPEASATIOV WILL BE MADE FOR ANY EXTRAS DIE TO CONTRACTOR'S FAILUE TO VISIT 77E ,.Y.BSI7E AAD /OR HREDEJERMIAE ALL EXISTING OOIDITIONS 85 SUBMITTING HIS BID. ANY DISCREPANCIES STALL BE IM ONA7ELY REPORTED 70 77E ETGIAE7R FUR RESOLUTION. 7. ALL WORK ShALL BE OCMPLETED IN ACCOFDAACE IVI7H ALL APPLICABLE COVER/ VT AAD LOCAL OODES. H. V. A.C. AD7E3: 1. EXISTING BLOND? COIL AAD FEAT PLOP ON ROOF TO REMAIN. BALAACE 7O 2000 LFM. 2. EXISTING DUCT /EATER TO REMAIN. 2 H.V.A.C. PLAN SCALE: 1/4" = 1' - MANAGER 106 0 PLUMBING PLAN SCALE 1 /e = 1' -O" PLLIBIAG AD7E2 1. 1/2' VALVED COLD WATER DOWN TO IC.EMAKER AT REFRIGRAla4. 2. CO ECT AEW PIPING TO EXISTING PIPING OF EQUAL 0? CREAM? SIZES. VERIFY LOCATION OF EXISTING PIPING PRIOR TO COA57ROCTIOV 3 SPACE RESERVED FOR ELECTRICAL EQUIPMENT. NO IEJY PIPIAC SHALL CROSS THIS AREA WITHIN THE BUILDIAG 4. WATER /EATER (H1 1). AN7 EXPANSION TAM' (ET-1) MOUWED H ILT/ IN CLILIAC SPACE. PROVIDE DRIP PAN FOR WATER hEA7ER.4AD EXPANSION TAN( (ET -1). PIPE RELIEF 4D DRAIN FROM DRIP PAN 70 EXISTING LALICRY TLS. MAINTAIN A 2' MINIMA/ AIR CAP. 2' 4 8' INVENTORY 1 109 HALLWAY 1 105 L EX /STING LAUNDRY 77/8 70 REMAIN. SANITARY RISER DIAGRAM NO SCALE rvi 0 fr�T7 7 NOTE 2 1/2- 1 108 1/2' ET-1 1/2 r - 3/4 L ;2NOTE NOTE 3 r1 HWH -1 NOTE 4 1 1/2' -4 NOTE 2 I CCI�p W DYED PR 2 7 'L � NO fED skikt COPYRIGHT 72000 CALLISON ARCHITECTURE, INC. z O 411. — CO w w CC Z 0 N CC w oIL co Q Q 70 LL < LLI Lr Z Z H u) CO CV CO ISSUED / REVISED DATE PERMIT ISSUE 04-23-01 PERMIT ISSUE APRIL 23, 2001 MECHANICAL PLANS RECEN =U M 1.00 APP, 2 5 2.001 FERN, CENTER SYMBOLS P L U M B I N G SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION 02 SANITARY DRAIN ABOVEGROUND —4D— GAS COCK 0.013E VALVE pQWC WATER CLOSET (TANK TYPO ♦' SANITARY DRAW. BELOWGROUND VENT LINE — ICI — CHECK VALVE IcC) WC WATER CLOSET (FLUSH VALVE/ —S— STORM DRAIN ABOVEGROUND Q PRESSURE RELIEF VALVE 0 UR URINAL Sx. STORM DRAIN BELOWGROUND " STOP AND WASTE VALVE AND WASTE VALVE ON RISD 10 LAV LAVATORY — - -- COLD WATER (CV) HOT WATER OM nRI STOP MIXING VALVE KS KITCHEN SIKK ----- —C— HOT WATER CIRCULATING (RING) GAS LIf� SQUARE CEILING DIFFUSER PRESSURE REGULATING VALVE (PR, SS SERVICE SINK +H— UNION FINHB HOSE al. rl DF DRINKING FOUNTAIN tiJ — 0 - -. STRAINER BALANCING COCK I- (;TEN WALL HYDRANT FIRE HYDRANT t ID EWC ELECTRIC WATER COELER —0-0 -- el RUNNING TRAP 0 M MANHOLE 1:>— COLUMN NUMBER W CLEAN OUT GRADE CLEAN OUT +-R.0 CID -1 VALVE IN RISE DRAIN AND MARK PLUMBING RISER NUMBER NLT.L NOT IN THIS CONTRACT ORD ROOF DRAW VTR VENT THROUGH ROOF ODS DOWN SPOUT - - ICJ -- 1>4 VACUUM BREAKER BALL VALVE V.CP. LI. VITRIFIED CLAY PIPE CAST IRON IE. INVERT ELEVATION SYMBOLS HEATING-VENTILATING-AIR CONDITIONING SYMBOL DESCRIPTION T �y THERMOSTAT QS REMOTE SENSOR 02 SUPPLY DIFFUSER CEILING RETURN OR EXHAUST GRILLE TITUS SUPPLY OR FRESH AIR DUCT ♦' (SA OR FA) SUPPLY RETURN OR EXHAUST AIR DUCT AC TILE (RA OR EA ) RECTANGULAR DUCT FIRST FIG IS SIDE SHOWN �. 5-1 ROUND DUCT A 51E A � 2 °m EL q VOLUME DAMPER (ELEV AND PLAN) 50F X X 1 26 B TURNING VANES CFE SUPPLY REGISTER OR GRILLE (R OR 5) SSE RE URN REGISTER OR GRILLE (R OR 5) I SIZE SIZE ZE AIR INTAKE SIZE FRESH (FA) (.. ( SQUARE CEILING DIFFUSER -- t 1 � + \ (SUPPLY) DIFFUSERS, GRILLES AND REGISTERS MARK SERVICE LOCATION CLG. TYPE MANUFAC. CATALOG NUMBER REMARKS D -1 SUPPLY CEILING AC TILE TITUS TMSA XX 24x24 3 26 D -75 SEE PLANS FOR NECK SIZE D -2 SUPPLY CEILING AC TILE TITUS TMSA XX 12x12 1 26 5 -75 SEE PLANS FOR NECK SIZE 5-1 RETURN CEILING AC TILE TUTUS 50F X X 1 26 B SEE PLANS FOR SIZE ELECTRICAL HOT WATER HEATERS MARK LOCATION KW GAL/HR ® 90 DEGREE RISE ELECTRICAL STORAGE CAP MANUFACTURER REMARKS VOLTS PHASE HWH -1 CEILING 3 13.5 208 SINGLE 20 GALLONS A.O. SMITH MODEL NO, DEL -20 EXPANSION TANKS MARK LOCATION SERVES CAPACITY (GALLONS) WORKING PRESS (PSI) SIZE (APPROX) MANUFACTURER REMARKS ET -1 CEILING DOM. HW 2.1 150 10 "Mx10 3/8" AMTROL MODEL ST -5 -C FIRE PROTECTION SPECIFICATIONS 1. THE GENERAL CONTRACTOR SHALL SECURE THE SERVICES OF A LICENSED SPRINKLER CONTRACTOR FOR THE PURPOSE OF INSTALLING A COMPLETE AND FULLY AUTOMATIC AND OPERATIONAL SPRINKLER SYSTEM. 2. THE SPRINKLER CONTRACTOR SHALL USE A STATE LICENSED ENGINEER FOR THE PREPARATION OF SPRINKLER SHOP DRAWINGS. ENGINEER SHALL DESIGN A SYSTEM, WHICH SHALL CONFORM TO ALL LOCH:,, STATE, AND NATIONAL CODES, ALL LANDLORD CRITERIA AND ALL REGULATIONS OF ANY AGENCY HAVING JURISDICTION. 3. THE SPRINKLER CONTRACTOR SHALL SUBMIT THREE (3) SETS OF SPRINKLER SHOP DRAWINGS TO THE LANDLORD AND /OR HIS INSURANCE AGENCY FOR REVIEW AND APPROVAL PRIOR TO THE START OF ANY WORK. ONE 0) SET OF CITY AND LANDLORD APPROVED DRAWINGS SHALL BE FORWARDED TO THE TENANT PLANNING DEPARTMENT FOR RECORD. THESE SHOP DRAWINGS SHALL INCLUDE ALL NECESSARY HYDRAULIC CALCULATIONS OR PIPE SCHEDULES AS REQUIRED AND SHALL BEAR THE ENGINEER'S STAMP. CALCULATIONS SHALL INCLUDE THE FOLLOWING INFORMATION: A. RESIDUAL PRESSURE IN PSI AT POINT OF CONNECTION. B. SPRINKLER DENSITY FACTOR: (IN GPM /SQ. FT. PER 1500 SQ. FT. OF SPACE). C.) PROTECTION: ORDINARY HAZARD GROUP 2. D. GPM E. STATIC PRESSURE: (IN P51). 4. THE CONTRACTOR SHALL COORDINATE ALL SPRINKLER / FIRE PROTECTION WORK WITH THE LANDLORD AND /OR THE MALL MANAGEMENT STAFF IN ORDER TO ENSURE CONTINUOUS OPERATION OF EXISTING SYSTEMS. 5. THE CONTRACTOR SHALL VERIFY THE LOCATION OF THE LANDLORD'S MAIN FIRE PROTECTION WATER TAP AND COORDINATE CONNECTION THERETO LANDLORD AND SPRINKLER CONTRACTOR. 6. IF ANY PORTION OF THE EXISTING SPRINKLER OR FIRE PROTECTION SYSTEMS 15 TO BE REUSED, THE CONTRACTOR SHALL VERIFY THAT THE PLANS AND THE FIELD CONDITIONS ARE IN AGREEMENT. ANY DEVIATIONS SHALL BE REPORTED TO THE ARCHITECT AND THE TENANT. 7. THE GENERAL CONTRACTOR SHALL ENSURE THE COORDINATION OF ALL FIRE PROTECTION AND SPRINKLER HEADS WITH ALL OTHER EQUIPMENT AND TRADES. 8. SPRINKLER HEADS SHALL BE INSTALLED IN THE TOILET ROOMS, MANAGERS OFFICE, AND FIRE CORRIDOR CEILINGS AT THE CEILING HEIGHT SPECIFIED. SPRINKLER HEADS SHALL ALSO BE PROVIDED ABOVE THESE AREAS TO PROVIDE ADEQUATE COVERAGE PER CODE. 9. IF SPRINKLER SYSTEM IS EXISTING, THE SPRINKLER CONTRACTOR SHALL PERFORM ALL WORK NECESSARY FOR COMPLIANCE WITH THE NEW DESIGN. EXISTING SPRINKLER HEADS, BRANCH ONES, ESCUTCHEONS. ETC. SHALL BE REUSED WITH TENANT'S APPROVAL SUPPLEMENT EXISTING EQUIPMENT WITH NEW WHERE NECESSARY. 10. UPON COMPLETION OF THE ARE PROTECTION / SPRINKLER INSTALLATION, THE ENTIRE SYSTEM SHALL BE ACTIVATED AND TESTED IN ACCORDANCE WITH ALL CODES AND AUTHORITIES HAVING JURISDICTION INCLUDING LANDLORDS INSURANCE COMPANY. ALL TESTING REPORTS AND CERTIFICATES SHALL BE SUBMITTED TO THE LANDLORD WITH A COPY TO THE TENANT. 11. THE STORE SHALL BE PROVIDED WITH FIRE EXTINGUISHERS. THEY SHALL BE MOUNTED IN AN ACCESSIBLE LOCATION WITH THE TOP OF THE EXTINGUISHER 3.5 TO 5 FEET FROM FLOOR LEVEL (SECTION 10.504 UFC) 12. IF SURFACE UGHT FIXTURES IN ROOMS ARE LESS THAN 2' -0" WIDE. PLEASE NOTE, SPECIAL CLEARANCE REQUIREMENTS PER TABLE 4- 4.3.3.2.1 NFPA 13 15 REQUIRED WHEN OBSTRUCTIONS LOCATED BENEATH SPRINKLER HEADS WHEN THE OBSTRUCTIONS EXCEED TWO FEET IN WIDTH. ALSO REFER TO TABLE 4- 4.1.3.1,2 NFPA FOR PROXIMITY OF THE SPRINKLER HEADS IN REGARDS TO THE DEPTH OF ANY FIXTURE. 13. THE CONTRACTOR SHALL SUBMIT PLANS AND DETAILS SHOWING PIPE SIZES, HANGER TYPES, BRACING, ETC. FIRE DEPARTMENT WILL ISSUE SPRINKLER PERMIT UPON APPROVAL OF PLANS. IF THE JOB ONLY REQUIRES THE RELOCATION OF HEADS, AN INSPECTION 15 REQUIRED AND IF OVER 6 HEADS ARE ALTERED OR ADDED, A HYDROSTATIC TEST OF 50 PSI OVER STATIC (140 PSI) FOR TWO HOURS NEEDS TO BE CONDUCTED AND WITNESSED BY FIRE DEPARTMENT. 90 SECTION ELBOW 90 BRANCH TAKE -OFF NOT TO SCALE 45 ° THREE SECTION ELBOW 45 BRANCH TAKE -OFF TYPICAL ROUND DUCT FITTINGS P/MAITRIN; FIXTTRF SPFDIFICATIONS. SINK (S -1): FIXTLWE ELKAY AR- 2219, "LUSTERTONE" LR SERIES, SINGLE COMPARTMENT, 18 GAUGE, 302 (18 -8) NICKEL BEARING STAINLESS STEEL, WITH 1 -3/4" RADIUS COVED CORNERS, SELF RIAGTING, EXPOSED SURFACES ARE HAND BLENDED TO A HIC7iLICHSO SATIN FINISH, 7505RSIDE IS UNDERCOATED, • COMPARTMENT .4NTD FAUCET DECK ARE RECESSED 3/16" BELOW OUTSIDE EDGE OF SING 3-1/2" DRAIN DEERING, 22" X 79 1/2" OVERALL, X 7 -1/2" DEEP BOWL, 3 -HOLES ON 4" CENTERS. TRIAL• ELKAY ,K- 2423 -8H DUAL 4" BADE HANDLE SWING GOOSENECK FAUCET, DECK MOUNTED ESCUTCHEON, BRASS Ci7NS77?DCTION, 0507E PLATED, GOOSENECK SWING SPOUT EQUIPPED WITH AERATOR, REQUIRES 3 FAUCET HOLES. SIFPLIES 1/2" CHROME PLATED ANGLE STOPS WITH LOOSE KEY HANDLE, 1/2" CHROME PLATED FLEXIBLE BRASS RISER. WASTE ELXAY AK -35, STANDARD DUO STRAINER, FITS 3 -1/2" OPENING (4 -1/2" TOP DIAMETER), O/E PIECE STAINLESS CONICAL STRAINER BASKET WITH NEOPRENE STOPPER, CHROME PLATED BRASS TAILPIECE 1 -f/2" 17 GAUGE CHROME PLATED ADJUSTABLE BRASS P -TRAP WITH CLEANOUT PLUG, 1 -1/2" CY97OM/E PLATED BRASS WASTE TO WALL. TRANSFORMATION 90' ELBOW SUPPLY OR RETURN WYE (RECTANGULAR DUCT) I4 3/4 D RETURN AIR BRANCH FITTING' NOT TO SCALE NOT TO SCALE 7HREE TURNING VANES 45' ELBOW SIMILAR NO THROAT RADIUS TURNING VANES EXPANSION ROUND R/G1D DUCTWORK BRANCH SUSPENDED CELL /NG DUCT HANGER (TYP,) SHORT RADIUS 90' ELBOW TAKE —OFF USE ONLY IN AREAS WHERE SPACE IS LIMITED DUCTWORK DETAILS CONTRACTION FULL RADIUS ELBOW TAKE —OFF IN OF 8" HIGH STRAIGHT MERDCAL DUCT AT DIFFUSER CONNEC7ON DIFFUSER, SEE DRAWING FULL RADIUS DUCT CONNECTION TO CEILING DIFFUSER DETAIL ✓UNCDON BOX GA75 VALVE D /ELEC7R /C UN /ON WATER HEATER NOT TO SCALE GA5 5 METAL PAN 57771 DRAIN, SOLDER JOINTS AND CORNERS moko 77 POWER SUPPL Y METAL DECK // BAR 10 /ST TEMP. AND PRESS. RELIEF VALVE SUPPORT ANGLE 007/55770 WATER SUPPLY EXPANSION TANK SUPPORT ROD DRAIN VALVE —DRAIN LINE TO TENANT'S PLUMBING SYSTEM ELECTRIC HOT WATER HEATER DETAIL COPYRIGHT ©2000 CALUSON ARCHITECTURE, INC. w 1 w CC z 0 N CC w PERMIT ISSUE APRIL 23, 2001 ISSUED /REVISED DATE PERMIT ISSUE 0423-01 MECHANICAL SCHEDULES AND DETAILS NOTEV \ +48" MANAGER NOTE 1 (TYPICAL) A -39,41 A -2 57, 14A CONTACTOR yff A -21,23 INVENTORY HALLWAY x105 1 B -2,4,6 NOTE 9 A -16, NA 77902 #1 NOTE 1 A -3, 14A (TYPICAL) CONTACTOR H H 1 low (ID 411, Jie�i� RETAIL SALES 10 A -17 A -3,5, VIA CONTACTOR #1 (-0" POWER & SYSTEMS PLAN SCALE: 1/4" = r-0" 2' 4 8' GOER& ELECTRICAL NOTES 1. EXISTING CONDITIONS .SHOWN ARE BASED ON AS BUILT DRAWINGS PROVIDED BY'1TE OWNER AAD LIMITED FIELD IERIFICATIOV. COV7RACT0R SHALL ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE' TO THE 01/A R. 2. CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH DEMOLITION WORK PRIOR TO BIDDING AND' START OF WOW. CONTRACTOR IS RESPONSIBLE TO DEMOLISH ALL EXISTING AS REQUIRED FOR INSTALLATION /CONS7RWTION NEW WOW. 3. MAINTAIN CONTINUITY OF CIRCUITS AS AEEOED TO PROVIDE POWER 70 REMAINING DEVICES NOT BEING REMOVED L111R 77E DEMOLITION PLAN. 4. LIGHTING FIXTURES MARKED E" ARE EXISTING FIXTURES THAT ARE TO REMAIN IN PLACE. LIGHTING FIXTURES 171AT ARE MARRED "R" ARE EXISTING FIXTURES THAT HAVE BEEN RELOCATED. 5. RECD FLUORESCENT FIXTURES MAY BE REUSED AT THE CONTRACTOR'S OPTION. RELOCATED FIXTURES SHALL BE CLEANED, RELAADtD MO HAVE BALLASTS REPLACED AS NEEDED. NEW AAD RELOCATED FIXTURES SHALL NOT BE MIXE0 IN 77E SAME ROOM. 6. DISPOSE CF ALL EQUIPMENT NOT REUSED AS PART OF THE AE11 WORK AS DIRECTED BY 111E OWNER. 0 _ LIGHTING PLAN - it07 SCALE: 1/4" = 1' - 0" o ��_� , � - a' e . A- 21,2225 NEW PANEL "B B "� BREAKROOM I 10 B- 8, EX/S77NG PANEL A A - 18, L WH -1 (20/2) 301/2 N B -8 L3 -30P B -8,10 B -11, (30/1, 10 WORE) ELECTRICAL NOTES 1. RECEPTACLES AT SLATWALL MUST BE LOCATEIO AS SHOWN ON PLAN. MOUNT AT +1" A.F.F. HORIZONTALLY, SWITCH TO ALLOW OPERATION OF LIGHT FIXTURES ,¢'5 AND ,6. SUFFIX 1" DENOTES HORIZONTAL MOUNTING, ELEVATION TO CENTER OF DEVICE. SEE DETAIL 1/7201. 2. POWER FOR RECESSED LIGHTBOX, SEE DETAIL 3/7201. 3. POWER FOR SECURITY EQUIPMENT, SEE DETAIL 5/7201. 4. DATA TO BE INSTALLED BY VERIZON WIRELESS, TYPICAL. 5. SEE DETAIL 2/7201 FOR POWER FEED INFORMATION AT SALES DESK, TYPICAL. 6. POWER FOR PLUGSTRIP, SEE DETAIL 4/7201. 7. JUNCTION BOXES FOR POWER AND DATA IN CEILING SPACE. COORDINATE WITH VERIZON PROJECT MANAGER FOR FINAL PLACEMENT PRIOR 70 ROUGH -IN. 8. SEE SWITCHPLATE ELEVATION, 7/72.01, FOR SWITCHING SCHEME TO SALES LIGHTING. LOWER CASE LL / /1795, SHOWN ON PLAN, FROM LIGHTING CIRCUITS CORRESPOND TO SWITCHES ON ELEVATION. 9 J-BOX FOR EXTERIOR SIGNAGE SHALL CONTAIN 120120 AAP CIRCUITS. ALL PRIMARY WIRING BY ELECTRICAL CONTRACTOR TO 77E SIGN MUST BE PER UL2161 FOR CFI SIGN TRANSFORMERS. 012161 REQUIRES THAT ALL CIRCUITS MUST HAVE .4 DEDICATED HOT, NEUTRAL AAD GROUND TERMINATING AT RE ELECTRICAL PANEL. COORDINATE WITH VERIZON PROJECT MANAGER. 10. PROVIDE JUNCTION BOX IN CEILING SPACE FOR SICNAGE, PROVIDE TWIST -LOCK RECEPTACLE. COORDINATE WITH VERIZON PROJECT MANAGER. 11. ELECTRICAL CONTRACTOR TO PROVIDE 1100 LUNEN EMERGENCY BATTERY PACK ON RELOCATED FIXTURES EM ". 1,P ROV D PR 2 7 2001 N 93109 D1W6 D1/ LEGEND EX/S17NG -NEW WORK NEW TO EXIS77NG CONNECTION COPYRIGHT ©2000 CALLISON ARCHITECTURE, INC. L >" Z it 13 ^ U 0 4 m r Y E eLP PERMIT ISSUE APRIL 23, 2001 E1.00 E O U M wC 06 J O) 0 N 111060) moo 3 0 0 Z o j N 3 M ° o �M0] U z M fr 1 N U I]J 0 < C CCO 9) L O ° z N 6 # 0 Q .L M M 9 0) 46 N N E J v - 6co.° 0, _JO �O O Q 7 O N N 0 IL Q 2 co E 'Z W W J OZUJ CC D CO o (9 ELECTRICAL PLANS ISSUED / REVISED DATE PERMIT ISSUE 0423-01 PERW CENTER APR 2 5 2001 : ) J s I I MANAGER i.._. r / t � /� V ii 1 N ®!!l����'�} h i ::: E s ( ���� L :. : � �. ice - �� aqa _� • t� I NVENTORY - � r i 49 !!!!! Fk►. �! � � .:-. - I .1111111.1M ! !!. ! .! !_ L . I .: 1 �r =� �C �!"�� \ ' � :`' J.' I I ,� IM ►�! ��� k � I I !! � •!! 1 . .irimI mum, EAKROOM . M� / !l., 1 lO8 !!I MI MN= !!!!rte ■M !! 1 EX /SnNG A . PANEL '" �!� !!, � II __ _,_ _ 11111111•1111 �� kw � ;! : ; 1 111 1 lilili 1 \�! ■!!1� ■!��!!!r!i Nil 1111 rAm Emg -- !!!! ■ `' I !! ©. � I • • r !fir �t'0• 1 : u MUM= !!! ! E —•! © 1 1 - jug �• ' _ II n ��,� -� • - �r 11 / 1 � ��f((f�� \� -� ® OA .9 b o ___ ►�. !!■■!�!! !!.i!!�!!!•!! OP_ . • .. •uM�■•••_•■ ®M ir , I 1�1 ° ar 6 w © Elk ■ ii!lbiamilim biii i i �bli lfE " s '�° I NOTE 11 NOTE 1'-/ HALLWAY , �� � NOTE 11- NOTEV \ +48" MANAGER NOTE 1 (TYPICAL) A -39,41 A -2 57, 14A CONTACTOR yff A -21,23 INVENTORY HALLWAY x105 1 B -2,4,6 NOTE 9 A -16, NA 77902 #1 NOTE 1 A -3, 14A (TYPICAL) CONTACTOR H H 1 low (ID 411, Jie�i� RETAIL SALES 10 A -17 A -3,5, VIA CONTACTOR #1 (-0" POWER & SYSTEMS PLAN SCALE: 1/4" = r-0" 2' 4 8' GOER& ELECTRICAL NOTES 1. EXISTING CONDITIONS .SHOWN ARE BASED ON AS BUILT DRAWINGS PROVIDED BY'1TE OWNER AAD LIMITED FIELD IERIFICATIOV. COV7RACT0R SHALL ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE' TO THE 01/A R. 2. CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH DEMOLITION WORK PRIOR TO BIDDING AND' START OF WOW. CONTRACTOR IS RESPONSIBLE TO DEMOLISH ALL EXISTING AS REQUIRED FOR INSTALLATION /CONS7RWTION NEW WOW. 3. MAINTAIN CONTINUITY OF CIRCUITS AS AEEOED TO PROVIDE POWER 70 REMAINING DEVICES NOT BEING REMOVED L111R 77E DEMOLITION PLAN. 4. LIGHTING FIXTURES MARKED E" ARE EXISTING FIXTURES THAT ARE TO REMAIN IN PLACE. LIGHTING FIXTURES 171AT ARE MARRED "R" ARE EXISTING FIXTURES THAT HAVE BEEN RELOCATED. 5. RECD FLUORESCENT FIXTURES MAY BE REUSED AT THE CONTRACTOR'S OPTION. RELOCATED FIXTURES SHALL BE CLEANED, RELAADtD MO HAVE BALLASTS REPLACED AS NEEDED. NEW AAD RELOCATED FIXTURES SHALL NOT BE MIXE0 IN 77E SAME ROOM. 6. DISPOSE CF ALL EQUIPMENT NOT REUSED AS PART OF THE AE11 WORK AS DIRECTED BY 111E OWNER. 0 _ LIGHTING PLAN - it07 SCALE: 1/4" = 1' - 0" o ��_� , � - a' e . A- 21,2225 NEW PANEL "B B "� BREAKROOM I 10 B- 8, EX/S77NG PANEL A A - 18, L WH -1 (20/2) 301/2 N B -8 L3 -30P B -8,10 B -11, (30/1, 10 WORE) ELECTRICAL NOTES 1. RECEPTACLES AT SLATWALL MUST BE LOCATEIO AS SHOWN ON PLAN. MOUNT AT +1" A.F.F. HORIZONTALLY, SWITCH TO ALLOW OPERATION OF LIGHT FIXTURES ,¢'5 AND ,6. SUFFIX 1" DENOTES HORIZONTAL MOUNTING, ELEVATION TO CENTER OF DEVICE. SEE DETAIL 1/7201. 2. POWER FOR RECESSED LIGHTBOX, SEE DETAIL 3/7201. 3. POWER FOR SECURITY EQUIPMENT, SEE DETAIL 5/7201. 4. DATA TO BE INSTALLED BY VERIZON WIRELESS, TYPICAL. 5. SEE DETAIL 2/7201 FOR POWER FEED INFORMATION AT SALES DESK, TYPICAL. 6. POWER FOR PLUGSTRIP, SEE DETAIL 4/7201. 7. JUNCTION BOXES FOR POWER AND DATA IN CEILING SPACE. COORDINATE WITH VERIZON PROJECT MANAGER FOR FINAL PLACEMENT PRIOR 70 ROUGH -IN. 8. SEE SWITCHPLATE ELEVATION, 7/72.01, FOR SWITCHING SCHEME TO SALES LIGHTING. LOWER CASE LL / /1795, SHOWN ON PLAN, FROM LIGHTING CIRCUITS CORRESPOND TO SWITCHES ON ELEVATION. 9 J-BOX FOR EXTERIOR SIGNAGE SHALL CONTAIN 120120 AAP CIRCUITS. ALL PRIMARY WIRING BY ELECTRICAL CONTRACTOR TO 77E SIGN MUST BE PER UL2161 FOR CFI SIGN TRANSFORMERS. 012161 REQUIRES THAT ALL CIRCUITS MUST HAVE .4 DEDICATED HOT, NEUTRAL AAD GROUND TERMINATING AT RE ELECTRICAL PANEL. COORDINATE WITH VERIZON PROJECT MANAGER. 10. PROVIDE JUNCTION BOX IN CEILING SPACE FOR SICNAGE, PROVIDE TWIST -LOCK RECEPTACLE. COORDINATE WITH VERIZON PROJECT MANAGER. 11. ELECTRICAL CONTRACTOR TO PROVIDE 1100 LUNEN EMERGENCY BATTERY PACK ON RELOCATED FIXTURES EM ". 1,P ROV D PR 2 7 2001 N 93109 D1W6 D1/ LEGEND EX/S17NG -NEW WORK NEW TO EXIS77NG CONNECTION COPYRIGHT ©2000 CALLISON ARCHITECTURE, INC. L >" Z it 13 ^ U 0 4 m r Y E eLP PERMIT ISSUE APRIL 23, 2001 E1.00 E O U M wC 06 J O) 0 N 111060) moo 3 0 0 Z o j N 3 M ° o �M0] U z M fr 1 N U I]J 0 < C CCO 9) L O ° z N 6 # 0 Q .L M M 9 0) 46 N N E J v - 6co.° 0, _JO �O O Q 7 O N N 0 IL Q 2 co E 'Z W W J OZUJ CC D CO o (9 ELECTRICAL PLANS ISSUED / REVISED DATE PERMIT ISSUE 0423-01 PERW CENTER APR 2 5 2001 G BOL_____. SYMBOL DESCRIPTION SYMBOL DESCRIPTION ® CEILING MOUNTED CONVENIENCE OUBET lD FIRE ALARM BREAK GLASS STATION DESCRIPTION DUPLE( CONVENIENCE OUTLET 1]F R FIRE ALARM MAGNETIC HO'W OPEN OR .t DOUBLE DUPLEX (4 -PLEX) CONVENIENCE OUTLET E l Fl RE ALARM CONTROL PANEL -e SINGLE CONVENIENCE OUTLET I> FIRE ALARM VISUAL INDICATOR -9 OR ® 20 A 250 V. WALL OR FLOOR OUTLET SERVICE AREA LTG EIRE ALARM HORN (11 OR ® 30 A 250 V. WALL OR FLOOR OUTLET p DI q 83 FIRE ALARM HORNCASUAL COMBINATION F032/841 50 A 250 V. OUTLET e- ARE ALARM AUTOMATIC HEAT DETECTOR HEAD CF FLOOR CONVENIENCE OUTLET $ fl RE ALARM AUTOMATIC SMOKE DETECTOR HEAD UTHONIA FLOOR 4 -PLE% CONVENIENCE OUTLET $ DUCT MOUNTED SMOKE ALARM ■ ULTI- OUTLET ASSEMBLY DEDICATED RECEPTACLE $ 0 CARBON MONOXIDE DETECTOR HEAD MOTOR I DEDICATED FLOOR RECEPTACLE a DISCONNECT SWITCH - NON -FUSE UNLESS OTHERWISE NOTED 0 POWER POLE $ FUSED SWTCH -0 OR -9- JUNCTION BOX WALL ® MAGNETIC CONTROLLER O JUNCTION BOX CHUNG � coMB MVP MRNEBC CMNTRa O MRM RON-EUSE DISCONNECT LINDEN OTUDrvnSE NOTED. O OR 0 JUNCTION BOX FLOOR R POWER RELAY 15 UGHTNG OR POWER PANEL � � V� ELECTRIC SOLENOID VALVE 6 MAIN DISTRIBUTION PANEL O THERMOSTAT 75W MR16 FL BRANCH CIRCUIT - EXPOSED ® CON TRANSFORMER �\ BRANCH CIRCUIT CONCEALED IN WALL OR CEILING B SINGLE PUSH - BUTTON BR FIXTURE DRANCH CIRCUIT CONCEALED IN FLOOR _ Q M OTOR CONTROL PUSH - BUTTON STATION 120 N OME RUN TO PANEL - NUMBER OF CIRCUITS INOICAIEU BY UMBER OF ARROWS - R TUTEES UNlE55 OTHFAMSE NOTED. a BUZZER - R TELEPHONE RACEWAY - 3/4' UNLESS OTHERWISE NOTED. d CHIME /S1 SOUND SYSTEM RACEWAY - 3/4" UN LESS OTHER SE NOTED. Do BELL /R\ ARE ALARM SYSTEM CIRCUIT 0 CEILING SPEAKER OUTLET /TV\ OTTER TELEVISION ANTENNA RACEWAY - 3/4' UNLESS ORR\RSE NOTED. ti WALL SPEAKER OUTLET /O''\ EMERGENCY ORCUIT ® FLOOR MICROPHONE OUTLET —. CIRCUIT DO NN -8 WALL MICROPHONE OUTLET �---, CIRCUIT UP CD SECURITY CAMERA $ SINGLE SWITCH -- SECURITY CAMERA WITH IRIS $ 3 -WAY 5',MTCH -El WALL TELEVISION ANTENN OUTLET $ 4 -WAY SWITCH IWN CRUNG MOUNTED TELEVISION ANTENNA OUTLET $D DIMM SNITCH -IEI ALL MOUNTED VOLUME CONTROL A 50/3 SUBSCRIPT FOR ALL RECEPTACLES & SWITCHES 'P' DENOTES SWITCH WITH PILOT LIGHT IN TOGGLE 'T' DENOTES SWITCH WITH TIMER 'WP' DENOTES WEATHERPROOF 'M" DENOTES MOTION DETECTOR • ALL SWITCHES SHALL BE MOUNTED AT +48' A.F.F. UNLESS NOTED El SECURITY ALARM CABINET j SECURITY DOOR CONTACTOR fC TELEPHONE OR CAN TERMINAL BOARD 4 TELEPHONE OUTLET o' FLUSH FLOOR TELEPHONE OUTLET 0� CAN CH UGHT FI XTURE, RECESSED OR SURFACE O FLOOR COMPUT OUTLE ER � 'V WALL MOUNTED UGHT FIXTURE, SCONCE -© WALL MOUNTED COMPUTER /DATA OUTLET L. WALL MOU NTED UGHT FIXTURE, FLUORESCENT O CHUNG MOUNTED COMPUTER /DATA OUTLET [�� = CEILING LIGHT FIXTURE, RECESSED OR SURFACE FLUORESCENT U COMBIN PHONE /DATA OUTLET F-�0� FLUORESCENT STRIP UGHT FIXTURE CE FLOOR ELECTRICAL ZONE "�'6 WALL MOUNTED EXIT UGHT RXNRE --Q DATA CONDUIT WALL BOX 41 CEIUNG MOUNTED EXIT UGHT FIXTURE W/ DIRECTIONAL ARROW I DATA CONDUIT FLOOR BOX t TRACK LIGHTING SPARE >KASTHERPHX NWADEIYDPEro4 OAR EIX IVIV pjiICATES NUME2AL IN OR NEPR LIGHT FIXTURE SYMBOL INDICATES FIXTURE TYPE CORRESPONDING TO A MARK NUMBER 0x1 THE LI GHTING : IXNRE SCHEDULE. GI SUBS r ?Sr APPVD) TO ANY SYMBOE INDICATES G+WND F A OLT CI IxIER P SUBSCRIPT "P" ADDED TO ANY SYMBOL INDICATES PILOT UGHT. K SUBSCRIPT 'K ADDED TO ANY SYMBOL INDICATES KEY OPERATED. LIGHTING FIXTURES MARK MANUFACTURER CATALOG NUMBER LAMP VOLTS MOUNTING REMARKS QUAN DESCRIPTION C W R P 1 UTHONIA 2PM3N- G- B- 3- 32 -18LS -120- GEBTORS 3 F032f841 120 20/1 B 20/1 X SERVICE AREA LTG 4 2 LITHOAIIA 2PM3N- G- B- 3- 32 -18L5 -120- GEBTORS-EL 3 F032/841 120 ENTRY TRACK LTG 6 X SALES RACK RECEPTS 900 3 UTHONIA 2SP- G- 3- 32- FW -Al2- 120 -GEB10 3 F032/841 120 SALES RACK RECEPTS 1080 X B 20/1 1500 4 UTHONIA 2SP- G-3-32-FW- Al2-120- GEB10 -EL 3 F032/841 120 C 20/1 1575 X 12 13 5 HALO C85261ECP- 8551 -LI 2 CF2610D /E/841 120 14 15 X 1000 20/1 6 UTHONIA DLV- WSH- MR16 -4AC -120 1 75W MR16 FL 120 360 20/1 X 200 UGHTING CONTACTOR 7 BR FIXTURE LL3-48"-WB-LP A-120- BK 500 20/1 120 1910 SUBFEED PANEL "B" 20 21 SEE NOTE 1 8 HALO L1738MB 1 75W PAR 38 120 X COPY /FAX 1000 20/1 : 650 NEXT B. PLAN SYMBOL TRACK LE 501 SERIES M TO TRACK 9 BRUCK LIGHTING TAKATO 330 1 50W MR16 120 X A 20/1 SPARE 26 10 UTHONIA F2RP -1 -RC- 120/277 -EL N -- SUPPLIED 120/277 X 28 29 SPARE 11 UTHONIA LQM- SW -1 -R- 120/277 -EL N -- SUPPLIED 120/277 X 1664 20/2 A 50/3 4800 12 UTHONIA 2PM3N- G- B- 3- U 31 -9LS -120 - GEB1ORS 3 F6031/841 120 8 - -- 4800 X 34 35 13 BR FIXTURE U_3- 24 " -WB- LPA - 120 -BK C - -- 4800 120 36 37 SPARE SEE NOTE 1 EXISTING PANEL A - - - 120/208 VOLT, 3 PHASE, 4 WIRE 225 A.M:L.O. SURFACE MOUNTED Na CKT LOAD SERVED V.A. C.B. P C.B. V.A. LOAD SERVED NOT 1 EXISTING FIRE ALARM 200 20/1 A 20/1 1010 SALES AREA LTG 2 3 SALES RACK RECEPTS 720 20/1 B 20/1 805 SERVICE AREA LTG 4 5 SALES RACK RECEPTS 720 20/1 C 20/1 450 ENTRY TRACK LTG 6 7 SALES RACK RECEPTS 900 20/1 A 20/1 1500 SALES TRACK LTG 8 9 SALES RACK RECEPTS 1080 20/1 B 20/1 1500 SALES TRACK LTG 10 11 LIGHTBOX 500 20/1 C 20/1 1575 SALES TRACK LTG 12 13 UGHTBOX 500 20/1 A 20/1 1212 BACKROOM LIGHTS 14 15 INTERIOR SIGNAGE 1000 20/1 8 20/1 1000 EXISTING SIGN CIRCUIT 16 17 SALES RECEPTACLES 360 20/1 C 20/1 200 UGHTING CONTACTOR 18 19 LIGHTBOX 500 20/1 A 35/3 1910 SUBFEED PANEL "B" 20 21 OFFICE RECEPTACLES 540 20/1 B - -- 1260 22 23 COPY /FAX 1000 20/1 C - -- 3280 24 25 BACKROOM RECEPTS 900 20/1 A 20/1 SPARE 26 27 INVENTORY RECEPTS 900 20/1 B 20/2 1498 WATER HEATER HWH -1 28 29 SPARE 20/1 C - -- 1498 30 31 EXISTING AHU 1664 20/2 A 50/3 4800 EXISTING AC COMPRSSR 32 33 1664 - -- 8 - -- 4800 34 35 SPARE 20/1 C - -- 4800 36 37 SPARE 20/1 A 60/2 4992 EXISTING DUCT HEATER 38 39 P.O.S.RECEPTACLES 720 20/1 B - -- 4992 40 41 P.O.S.RECEPTACLES 1080 20/1 C 20/1 SPARE 42 PANEL B 120/208 VOLT, 3 PHASE,: 4 WIRE 60 A.M.LO. SURFACE MOUNTED NO LOAD SERVED V.A. C.B. P C.B. V.A. LOAD SERVED NOT 1 SECURITY RECEPTACLE 180 20/1 A 20/1 830 REFRIGERATOR 2 3 ALARM RECEPTACLE 180 20/1 B - .20/1 180 BREAKROOM RECEPTS 4 5 INVENTORY PLUGSTRIP 540 20/1 C 20/1 180 BREAKROOM RECEPTS 6 7 INVENTORY PLUGSTRIP 540 20/1 A 20/1 360 DATA RACK 8 9 INVENTORY PLUGSTRIP 540 20/1 B 20/1 360 DATA RACK 10 11 U.P.S. 2200 30/1 C 20/1 360 PHONE BOARD 12 13 SPARE 0 20 /1 A LOAD TOTAL SPACE ONLY 14 15 SPARE 59332 20/1 B SPACE ONLY 16 17 SPACE ONLY C SPACE ONLY 18 LOADS BASED ON NATIONAL ELECTRIC CODE PANEL A CONNECTED LOAD BY PHASE TOTAL CONNECTED TOTAL W/ DIVERSITY 3 PHASE A B C UGHTING 1.25 4722 4305 2525 11552 14440 RECEPTACLES 3710 5220 4240 13170 11585 MOTORS 1 1664 1664 0 3328 3328 OTHER 1 200 1498 3898 5595 5595 KITCHEN 1 0 0 0 0 0 NON- SIMULTAN 0 0 0 0 0 0 HEATING ONLY 1 9792 9792 4800 24384 24384 COOUNG ONLY 0 0 0 0 0 0 EXIST. LOAD 1.25 0 0 0 0. 0 LOAD TOTAL 20088 22479 15463 58029 59332 TIMER SCHEDULE MARK SERVES PANEL POLES 1 ENTRANCE SIGNAGE (CIRCUIT A -16) A 1 2 LIGHTS BOX (CIRCUIT A- 1133) A 2 3 INTERIOR SIGN AGE (CIRCUIT A -15) A 1 4 UGHT BOX (CIRCUIT A -19) A 1 j l 8 NOTE: COORDINATE LOCATION WITH DMS FIXTURE MANUFACTURER FOR PRECISE LOCATION AND ELEVATION 1 OUTLET DIAGRAM NOT TO SCALE (3) 3=0" LONG PLUODS WTH OUTLETS ®6" O.C. GML TYP. 8 8 8 el 1 8 8 0 8 0 8 1 8 8 8 8 0 e l FLOOR SECTION PLUG S7R /P IN CABINET (DP. OF 5) LL7 121ID GROMMET IN CABINET OUTLETS (/N WALL) WITH (2) CIRCUITS FOR PLUG STRIPS FROM DESK r POWER FEED DIAGRAM@ 2 SALES & SERVICE DESKS NOT TO SCALE 9 SWITCH ON WALL p W771 PROTECTIVE COVER ON SWITCH SECTION THROUGH DESK ONDU /T TO r ABOVE 't s SUSPENDED CEIUNG u +� REMOVABLE TOE KICK SECURITY MONITOR F.O. /.O. VCR OCKBOX L �. �—�- F.O.I.O. OUTLET 0 PLUGMOLD ELEVATION DETAIL 0 SECURITY EQUIPMENT ELEVATION NOT TO SCALE NOT TO SCALE PHONE /DATA 61771 PULL R£ ALL EQUIPMENT PROVIDED BY VERIZON WIRELESS. (UNLESS OTHERWISE NOTED) HEAD BOTTOM FRONT OF UGHT BOX [NOTE: COORDINATE EXACT SIZE DIMENSIONS WITH VERIZON WIRELESS CD LIGHT BOX POWER DIAGRAM NOT TO SCALE 01 SECURITY CHEST AMERICAN SECURITY PRODUCTS CO. TOGGLE /SLIDE / 1 MODEL ,0 DSF2741 DIMMER SWITCH (FURNISHED AND INSTALLED (TYPICAL OF 4)- ( Y CONTRACTOR) t BOLT TO FLOOR POWER OUT or SIDE OF UGHT BOX LHALLWAY 105 L-CONTACTOR #1 (3 -WAY) CD SWITCHPLATE ELEVATION NOT TO SCALE NOTES: 1_ SUPPLIED BY VERIZON, INSTALLED BY ELECTRICAL CONTRACTOR. FIXTURE PLUGS IN TO +1" HORIZONTAL RECEPTACLES IN RETAIL SALES. TIMER NO= 1. TIME'? CAPACITY SMALL BE DETERMINED BY ELECTRICAL. CONTRACTOR AND STALL BE SIZED TO PROVIDE CONTROL. TO ALL. LIB THE DEVICES SHOWN. ACTUAL CIRCUIT CAPACITY SHALL BE TAKEN FROM ELECTRICAL PLANS. REPLACE IF REWIRED. CONTACTOR #2 F SWITCH CIRCUIT r I I .4-18 1 120 I — a FIELD WIRING I , NEUTRAL.. — -1 rn OfrO77 IXISIIN5 CONTACTOR CONTACTOR !2 EI :: LIGHTING CONTACTOR DIAGRAM NOT TO SCALE 4 - # #6 GROUND IN 2 1/2" CONDUIT 4 - # #10 GROUND IN 1" CONDUIT ONE -LINE DIAGRAM NOT TO SCALE ONE- -LINE AG7E.S• 7. REMOVE EXISTING METER SOCKET, IF NELSSARY, AAO REPLACE WITH AEW 200A MINIMUM METER SOCKET. 2. REMOVE EXISTING CIRCUIT BREAKER AND REPLACE WITH NEW 200/3 CIRCUIT BREAKER. A -3 'BR' FIXTURE A -5 'BR' FIXTURE A -7 'BR' FIXTURE A -9 'BR' FIXTURE SPARE SPARE A- SALES LIGHTING A -4 SERVICE LIGHTING SPARE PARE oil Of wikVE.0 APR 27 201 RS 6003) LEGEND EXISTING NEW WORK NEW TO EX/S77NG CONNECTION COPYRIGHT ©2000 CALLISON ARCHITECTURE, INC. 0 N N 07 CO 'D S m � p O) � L M M V E rn NN o < o o ° v O O U n 0 1- u. PERMIT ISSUE APRIL 23, 2001 E2.01 U z W P ;r 0 N s E lJjoO U o < C 0(06)0 1E f;i U Z <0K16 o O .0 P1 (6 0 _ � N N - : it 60 O V < O N N U T- co11-u. ISSUED / REVISED DATE PERMIT ISSUE 04-23-01 ELECTRICAL SCHEDULES AND DETAILS EGE + BD APR 252_00 PERMIT CENTER