Permit M01-120 - BOEING #9-96
p M01-120 Boeing 9-96 9725 East Marginal Wy S City of Tukwila Permit No: M01 -120 Type: B -MECH Category: NRES (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 08188 MECHANICAL PERMIT Address: 9725 EAST MARGINAL WY S Location: Parcel #: 000340 -0018 Contractor License No: BOEINC*294ML TENANT BOEING #9 -96 9725 EAST MARGINAL WY S, TUKWILA WA 98188 OWNER BOEING PO BOX 3707 - M/S 1F -09, SEATTLE WA 98124 CONTACT JOHN MURDOCH PO BOX 3999 M/C 89 -15, SEATTLE WA 98124 CONTRACTOR BOEING COMPANY PO BOX 3707, M/S IF -09, SEATTLE, WA 98124 REMOVE AND REDO FLEX AND APPROXIMATELY 2 X 2 CEILING GRILLS. REDO OF BUILDING (PHASE I) DUE TO EARTHQUAKE DAMAGE. UMC Edition: 1997 Valuation: Total Permit Fee: Status: ISSUED Issued: 08/03/2001 Expires: 02/04/2002 Phone: Phone: 253- 773 -0444 *********** **** * **** ** * * * * ** * *kk9e*** * kit*** * *:k *k: **** ** *** * * * * -k ** * *** *k* Permit Description: 80,000.00 80.75 • ******** * ** * **** * * * * * * * * * ** * ** * * ** **-k* Permit, Center Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to''be`.true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this .`b� "ldi j;:: permit 775 s me 2 Signature: 4*--- //0605Tl Print Name:_ 0 6 A4U N Title:_ a7,e cohoupee This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. ACTIVITY NUMBER MO1 -120 DATE: 07 -12 -01 PROJECT NAME: 9 -96 TENANT IMPROVEMENT SITE ADDRESS: 9725 EAST MARGINAL WAY S SUITE NO: Original Plan Submittal Response. to Correction Letter # Response to Incomplete Letter # Revision # AFTER Permit Is Issued DEPARTMENTS: Bujld9i�i division E Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete PLAN REVIEW /ROUTING SLIP Incomplete n Comments: TUES /THURS ROUT G: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved ❑ Approved with Conditions , ROUIL.00C srri Fire Peention AGv 1 - 4)i Structural PERMIT COORD COPY Planning Division Permit Coordinator No further Review Required im DUE DATE: 07 -17 -01 Not Applicable ❑ n DATE: DUE DATE 08 -14 -01 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWER'S INITIALS: DATE: 1.`t + ?a:n�ac4.i ACTIVITY NUMBER M01 -120 DATE: 07 -12 -01 PROJECT NAME: 9 -96 TENANT IMPROVEMENT SITE ADDRESS: 9725 EAST MARGINAL WAY S SUITE NO X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Not Applicable n Commend! TUES /THURS ROUTING: REVIEWER'S INITIALS: Structural Review Required n No further Review equjred Ti Please Route \6ti DATE: APPROVALS OR CORRECTIONS: (ten days) Approved Approved , w' ,th Conditions REVIEWER'S INITIALS: VMINOUIL.000 vrl PLAN REVIEW /ROUTING SLIP Fire Prevention Structural n n Ck,i A s it c r'r i dz po J Planning Division Permit Coordinator n DUE DATE: 07 -17 -01 DUE DATE 08-14 -01 Not Approved (attach om ents) n DATE: 1, b to CORRECTION DETERMINATION: DUE DATE Approved Ti Approved with Conditions Ti Not Approved (attach comments) REVIEWER'S INITIALS: DATE: PERMIT NO.: AA 0 ( MECIIANICAL PERMIT APPLICATIONS INSPECTIONS 00002 Pre - construction 00050 WSEC Residential 00060 WA Ventilation /Indoor AQC 00610 Chimney Installation /All Types 00700 Framing 01080 Woodstove 01090 Smoke Detector Shut Off ..X 01100 Rough -in Mechanical 01 101 Mechanical Equipment /Controls (] 01 102 Mechanical Pip /Duct Instil ❑ 01 105 Underground Mech Rough -in ❑ 01 115 Motor Inspection ❑ 1400 Fire Final 01800 Final Mechanical 04015 Special -Smoke Control System CONDITIONS 0001 No changes to plans unless approved by Bldg Div ❑ 0014 Readily accessible access to roof mounted equipment 0016 Exposed insulation backing material 0019 All construction to be done in conformance w /approved plans 0002 Plumbing permits shall be obtained through King Co 0027 Validity of Permit 0003 Electrical permits obtained through L & I 0036 Manufacturers installation instructions required on site "BTU maximum allowed per 1997 WA State Energy Code" 0041 Ventilation is required for all new rooms & spaces 0005 All permits, insp records & approved plans • available "Fuel burning appliances ❑' "Appliances, which generate...." 0 • "Water heater shall be anchored...." Additional Conditions: TENANT NAME: FEES Basic Fee (Y /N) Supplemental Fee (Y /N) Plan Check Fee (Y /N) Furnace /Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended /Wall /Floor - mounted Heater (qty) Appliance Vent (qty) Heating /Retiig /Cooling Unit /System (qty) Boiler /Compressor to 3 1IP /100,000 BTU (qty) to 15 1-1P /500,000 BTU (qty) to 30 1IP /1,000,000 BTU (qty) to 50 1 -1P /1,750,000 BTU (qty) over 50 I -IP/ I ,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) I lood (qty) Incinerator — Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) Add'I Fees — Work w/o Permit (Y/N) !lisp Outside Normal I lours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'I Plan Review (hrs) Plan Reviewer: Permit Tech: Date: Date: 0 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER M01 -120 DATE: 07 -12 -01 PROJECT NAME: 9 -96 TENANT IMPROVEMENT • SITE•ADDRESS: 9725 EAST MARGINAL WAY S SUITE NO: X Original Plan Submittal Response to Incomplete Letter # . Response to Correction Letter # Revision # AFTER Permit Is Issued DEPARTMENTS: Building Division Public Works Please Route C Li Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Incomplete n Comments: TUES /THURS ROUTING: Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Fire Prevention Approved ❑ Approv with Conditions REVIEWER'S INITIALS: 17( Planning Division n Permit Coordinator No further Review Required n DUE DATE: 07-17-01 Not Applicable n DUE DATE, 08-14-01 Not Approved (attach comments) n DATE: fit - V i CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Project Name/Tenant: qq Value of Mec +,'i,a)uipment: Site Address : q e � ^ , , / t State/ Tax Parcel - 0 Property Owner: B^/m AweAi jr J Phone: ( G 2 .. e , L I Street A Pes . 8 s M / 2 g 9.. / �ale�Z t (� rG Fax #: ( 3 . , e Rt2a . Contractor: sb(:. IN 21 oftL q2121/ Phone: ( ) Street Address: v City State/Zip: Fax #: ( ) Contact Person / 2 , L / we - 2t Phone: 3 ).42 � e,/w rdd /C� X, R9 A gi-1 Qir it�� Fax #: ( ) 27 .a`.e a ;`BUILDING. ! .° �► f 4U ORIZE0 .AGENT : :... . ,.; .:. .. ,Signature: dV,Pied /771 -7-1_16- • Feria �� w Date / zL�v Print nam . S / ,/ U �� ~ , , ` "I ^, / , -./5 Phone: (3) ..��r / 9 7 � Fax #: ( ) � t.-r1�_e: E _ n,r 4/g r // [ Address:pe c aw City/State/Zip: CITY OF?UKWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 FOR STAFF UST ONI Y Project Nu, r: Permit Number: !vial - 11,0 Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsi►nik. MECHANICAL PERMIT REVIEW AND APPROVAL'REQUESTED: (TO , BE.FILLED OUT BY APPLICANT) Descri tion of work to be done (please be spe ' ' K vc s eDO t .9 z$z aett ij& ,e 0 /GU,Hb (p, doe 1 8 // J' a ap~,t5 Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF C RJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: 7 75 - 40/ Date application expires: /-/3 o2- Applic ' n taken by: (initials) 11/2/99 meth pemdl.doc ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Forni: #H '. H.V.A.C. over 2,000 CFM.(approximately 5 ton and larger) mustbe provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacem`e equipment complies with the efficiency ratings and other applicable requirements of the Washingtoni State'Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. ) { 11/2/99 ,nlscpnu.doc Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code - please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications. Change or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Address: 9725 EAST MARGINAL WY S Permit No: M01-120 Suite: Tenant: BOEING #9-96 Status: ISSUED Type: 8-MECH Applied: 07/13/2001 Parcel #: 000340-0018 Issued: 08/08/2001 ****************************4(**********kAA***A*******A***********kk****%Ak* Permit Conditions: I. Any exposed insulations backing material shall have a Flame ,Spread Rating of 25 'or less, and material shall bear identi- ficetion showing the fire performance rating thereof. 2. ,Plumbing permits shalllie,obtained through the Seattle-King County Department of Public Health. Plumbing will be inspected by thataency, including all gas piping (296-4722). 3. Electrical permits shall be obtained through the Washington State Division ci-"f Labor and Industries and all electrical' work will bekipSpected'by that. agency (248-6630)." No changes idlA be made,to unless approved by the Engineer arid (the Tukwila ,Building Division. • All permit,.' iniReption r'eco'rds, and approved plans shall be the'Sob;site-pritir'to the start of any con- istructio&d; These documents are tope 4 maintained and avail- able All donstructlowto be done in conformance with approved plans and of the Uniform Building Code (1997 amended, Uniform Mechanical Code (1997 Edition),. and Washington State Energy Edition). • 7. Validity, of Pehoit. The issuance :of or approval 0f ,-, plans, specifications, and computations shall not be con- ". strued to4e a,!permit for, or an approval,of,.any violation of any ofthe provisions of the building code or of any other ordi,nance,of jurisdiction. No permit presuming to give authority to 'Violate or cancel the provisions of this codeshallbe,valiA,-- , • , Manufacturers.'instellatiOn instructions required on site CITY OF TUKWILA for the building inspectors review. ***FIRE DEPARTMENT, CONDITIONS*** • • The attached set 'of plans have been reviewed by The Fire , Prevention Bureatiend are acceptable with the following 3concerns: k • Maint Jan sprinkler coverage per N.F:P.A. 13. Addition/relocation of ia1l c or partitions may require relocating and/or aAdin4 12"." ,Sprinkler protection shall be ekeehdedl.to'all'areas where required, including all enclosed areas, below obstructions and under overWangs greater than four feet wide. (NFPA 13-4-5.5.3.1) 11. All new sprinkler systems and - '611' modifications to existing sprinkler systems shall have fire department review and . approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written 'approval of the W.S.R.B., Factory Mutual, Industrial Risk insurers, Kemper or any other representative designated / ,and/or recorgnized by the City of Tukwila, prior to , submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) • Any overlooked hazardous condition and/or violation of the 'adopted Fire or Building Codes does not imply approval of such condition or violation. 16, THESE PLANS WERE REVIEWED BY INSPECTOR 511. IF YOU HAVE • ' ANY QUESTIONS, PLEASE CALL THE TUKWILA FIRE PREVENTION 'BUREAU AT (206)575-4407. hereby. certify that I have rea0,these will comply with them as outl ined. Al I provisions of law and Ordinances governing this work will be compliedwithi whether specified hereinlor not. The granting of this permit does not piesuMe,to authority ;to violate or cancel thaprovislons of any other work or local laws. regulating co tructlAn or,,4he performance of work. •••,- '••'•••• ,• • • e,• ILIC); ' 5PralMi,41.„.,A , ... • .4-. ,, ,. ;; , ,,, t lill *: R .1il a 1 0 ••••' : I; i' UJ a ,. .z MECHANICAL PERMIT r PE.r i ID 4 ' MARGINAL NY 8 X_ Total Fee's: 80.75 hTe•:j.:TaiMent- 80 75 Total ALL Pmts 80.75 Dalancei .0 .4.r ;./■• * 4 1.“ ;A; IA "ic ir * ,ir A * * A. ** Or -A *A 4-ir * *Iv *lc* * too * A ilc ii-* A * ***iv* A * * ** * A. * lelt-A * Ittlir * 1 , 1 CCpallgoCle::. .- f : Amount :. 00/34 830 PLAN CHECK - NONRES 16.15% MECHANICAL -. MONRES .64.60 ', .,. •!. , . i — 1 • 1 permit No: M01-120 Type: 8-MECH 2%. iv.k******tr4s*A***4 k•kle k4chic*A*A*,4 A k* 4ekh**A-ir A-kir kAkA .4**fr A *ir k A kit** k OITY OF TUKWILA. WA TRANSMIT ******4***AkA***A TRANSMIT Number: R0101019 Amount: 80.75 08/08/01 15:12 Payment Method: CHECK Notation: JOHN S.; MURDOCH In KAS iC 0/09 9/i� . 'TOTAL. '161.50" '0•Nizat 440 iii LU; r4 2 g 2 w •, .9 Project ; Type of Inspection: Addres "; • f '�'-� 4/ Date called3* rye . �7 / " Special instructions: _ Date wanted: / a.m. Requester: Phone: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100 ; :Tukwila, WA 98188 ( 06)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: off- 7:6 ,Z ,) / _ ,<< a $47.00 REINSPECTI sif FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter : vd., Suite 100. CaII to schedule reinspection. Receipt No: Date: • Project: q to Type of Inspection: i i •Adess: , MrAr .1 ) Date called: i0 -01 Special instructions: 1 Date wanted: / 0_0). raT)11. G Requester: Phone: INSPECTION RECORD Retain a copy with permit INSPECTION NO. • crry OF TUKWILA BUILDING DIVISION -„ 6300 Blvd, #100, Tukwila, WA 98188 Inspector. i if • PERMIT NO. Jc (206)431-3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: • Silnoktr, noAres, oj ‘ ‘4)nr\t corstecki 10 clone Date: II ._ 9 _ 1 Li) . .0:$47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I LISL4,4ftrafeadi Atibietag Receipt No: Date: " • • : • • • '•••• • . 7 .; '•,• • ••• • • • • , . • t• • •. • • - .••"; • ..• , • , . • • . • • • •:,•• :•; , • :• ; CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431-3670 INSPECTION RECORD Retain a copy with permit INSPECTION O. PERMIT NO Af Ins R l) dre Special instructions: LU S proved per applicable codes. Date ' Datg 10 At!" Requester Phone. El Corrections required .PHOi.to COMMENTS 4 rA cFr4 24,4 3 • ' . • Date: , . • Date: fl $47.00 REINSPECTION F REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinipection. 1Receipt No: 15. . . • .: .„ L. A.,=14 • ■ INSPECTION RECORD • Retain a copy with permit INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 COMMENTS: F Moo • - TO 4C4) -- < )l o_\ 'r) - pprOVe(J GL ;„2-h-4 32 0,"1 21)0F ZI 'Approved per applicable codes.. Corrections required prior to approval. InspedorraS, Date: 0 ) $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: • 0p02 Addres : / C rO s 5 - 6- fri / ai -- Date call . j /3 1 / 0 Special instructions: J J Date anted. 97 / Reg ester: , c r TV Phone: c-20(0 3135 • ■ INSPECTION RECORD • Retain a copy with permit INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 COMMENTS: F Moo • - TO 4C4) -- < )l o_\ 'r) - pprOVe(J GL ;„2-h-4 32 0,"1 21)0F ZI 'Approved per applicable codes.. Corrections required prior to approval. InspedorraS, Date: 0 ) $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: • Project: {�l Cl;,h._c�c, „.� T f In e n: < 7 ` �b oue ceiii ^ Address: ”! l 0.5 E AAA Rci 'NA L WY,c Date lIled: l 5 ! L) / 0 f Special instructions: Da w nted: a.m two �S l n I p.m. Requ ster: c o 7`T" Ph 2 oti, - 7 X1 3 - 3)3S Approved per applicable codes. .64 f11.0aCogito.0622.6,10632.410X1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: , ,_th — pprov��� T . % e U( - 3:.h�t)1ci - 1 inn " A P rovC1 Inspector: Date: M El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection; fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: 1�° r' orY;;; 21� 'k�"�.+�`.Y.:f�':`•�4h`t�.s.�. �i'.r`v+',�,-= :3?�: rt Project: 13 rIP,11) * 9" ' T e of Inspection: 01 II ^ in Address: __ _ , ' :ivt.. I - P-5 --- ,E. Mk 1 AAj b de call , ey.9 n) ,Special instructions: ' 49 • Date wanted: a.m wi i ' i /ORD/ p.m: Requ ster: SCO-14- Phone: 2C r 9 „ • . INSPECTION RECORD Retain a copy with permit INSPECTION NO. ..CITY OF TUKWILA BUILDING,DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA. 9818 , . PERMIT NO. (206)431-3670 ID Approved per applicable codes. El Corrections required prior to approval. $47.00 REINSPECTION EEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: ( Floor GL +6 a2 A- --11) F 0 ) 411 /1 A rcl u • 9 Inspector: RN°4r?ltr:. Date 8'10 Receipt No: Date: gusenl#4,44141,4EiltittOgriaiii4olk..,:tettlgaWr4its.&,:attkatt,„4-1=14 Address Sprinklers: Fire Alarm: Hood &.Duct: Halon: Monitor: Pre =Fire Permits City of Thk$!ia Fire Department - n b4VO4,t:.+Y ' ��tiyr.t!; :i '. °dV�:� a� :�.�, ,Z�"X.,; , 5 Project. Name -eNv c1 -c )(0 Authorized Signature TURWILA.FIRE FINAL APPROVAL FORM Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Permit No. fl')O 1 - ‘21.) FINALAPP.FRM T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Suite # Date Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575 - 4430 Sprinklers: Fire Alarm: Hood & Duct Halon• Monitor: Pre -Fire: Permits: Headquarters Station; 444 Andover Park East • Tukwila, Washington 98188 . Phone: (206) 575-4404 • Fax (206) 5754439 ' n-- �• . ; 10,141,4. L }. l r i f'��r. 4, i�,•y. �y , `�n4;, ∎ :'a »_... � '1 7.7,777 4it e..'ti iJi�t "; � d "`k1'� " +'it•r:�:�0 , :. t'1.11q+'�";'. i �Y` Jvi'�+( j �' �� �I� tZ'` r < a +'S Ra �% �+� ��... 7 7.7 roj ect Name City of ? crkwfa Fire Department TURWILA FIRE DEPARTMENT FINAL APPROVAL FORM Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued 56 John W Rants, Mayor Thomas P. Keefe, Fie Chief Permit No. fr7( 2i) Date FINALAPP.FRM T.F.D. Form F.P. 85 April 11, 2002 Mr. John Murdoch P.O. Box 3999 M/C 89 -15 Seattle, WA 98124 Department of Community Development Steve Lancaster, Director RE: Permit Application No. M01 -120 Location: Boeing 9 -96 9725 East Marginal Way S. Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to schedule a progress or a final inspection A progress inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicant's control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to May 8, 2002, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Ajj iM Kathi A) Kathryn A. Stetson Permit Technician Xc: Permit File No.M01 -120 Bob Benedicto, Acting Building Official Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 SYM PROJECT SITE 14 -01 • 7 -127 REVISION U`+ 99 FROM SEATTLE TACOMA AIRPORT A BUILDING 9 -98 STRUCTURAL UPGRADE EAST MARGINAL WAY CORPORATE PARK DEVELOPMENTAL CENTER 703445 -03'' B BUILDING 9 -96 T.I. #1 J #715225 00', 599 TUKWILA BY DLR GROUP DLR GROUP APPROVED GM G.M FROM KENT & AUBURN DATE 04 24; 01 06.29.0' 90 SCALE SY Its • ( .0 REVISION PROJECT SITE 9-D4 s -77 it 00 9 -101 " 9- 120./j 9 -140 9 -98 B UILDING LOCATION BY 9 -110 MFC NO SCALE 13 -01 CHECK BOX El THESE DRAWINGS CONFORM TO THE 1994 U.B_C., U.F.C., U_P.C., AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. El ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10 —A. ® BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. ® NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE ❑ 1. TENANT IMPROVEMENT (STRUCTURAL) ❑ 5 SETS OF ARCHITECTURAL DRAWINGS ❑ 5 SETS OF STRUCTURAL DRAWINGS ❑ 5 SETS OF STANDARD DETAILS ❑ 5 SETS OF ENGINEERING CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS ❑ 5 SETS OF CONSTRUCTION SPECIFICATIONS El 2. TENANT IMPROVEMENT (NON— STRUCTURAL): ® 4 SETS OF ARCHITECTURAL DRAWINGS ❑ 4 SETS OF STANDARD DETAILS ❑ 4 SETS OF ENERGY CALCULATIONS ❑ 4 SETS OF CONSTRUCTION SPECIFICATIONS MECHANICAL, 4 COMPLETE SETS ❑ FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS El BRIEF PROJECT NARRATIVE: INTERIOR DEMOLITION OF 14,780 SF OF INTERIOR SPACE AND CONSTRUCTION OF GROUP B OCCUPANCY OFFICE. B®E7iW ® PROJECT CHECKLIST DATE CODE SUMMARY LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: TOTAL BUILDING FOOTPRINT TOTAL BUILDING GROSS FIRST FLOOR SECOND FLOOR PENTHOUSE BUILDING HEIGHT STORIES CITY OF TUKWILA 1994 U.B.C. ', U.F.C., U.P.C., AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. GROUP B TYPE II, N 101,717 S.F. 218,847 S.F. 101,717 S.F. 101,717 S.F. 15,413 S.F. 44 FT. 2 7 1-/zo HANDICAPPED REQUIREMENTS BARRIER FREE FIRE 1RROTECTION FULLY AUTOMATIC, F/S ,CLASS 1 SPRINKLERS THROUGHOUT SEISMIC' °ZONE 3 SUBTITLE T E BUILDING 9 -96 TENANT IMPROVEMENT #1 BUILDING 9 -96 CURRENT REVISION J #715225 -00 SHEET SYMBOL DATE 06.29.01 VICINITY MAP FROM DOWNTOWN SEATTLE 900 EXIT, 157 900 UIL AREA MAP BUILDING ADDRESS: 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON APPROVED DATE ANT IMPROVEMENT #1 BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2_ NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3., COORDINATE WORK WITH OTHER CRAFTS. I 4. RETURN THIS SAME SET TO GARY TALLER AT BLDG. 9 -51 COL N/1, AFTER COMPLETION, OF THIS CONSTRUCTION. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED'. DEP DATE DRAWN NECKED NGINEER CHECKED APPROVED APPROVED APCAIT V YTI 190 14ACTEP FILE COPY I understand that the Plan' Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. s acknowledged. a Receipt tractors copy of approved plan 44 Permit No. f .1 Zo 10A15 szO No oNpAoss 1�1�J B� tv 1P pR 0` h�P YIO L7 33of a� SEPARATE PERNUT REQUIRED FOR: 0 FFECHANICAL ELECTRICAL d [J GAS PIPING CITY OF TUKWILA BUILDING DIVISION G1 Ti JOB 'NO 4715225 -00' DWG NO fi0IUEU + . U TUKWILA c099 ;g1 Q — QF. i "T11n417GENTEFI '., 2/20 36/12 42/20 D -1 10 "0 320 CFM 24X24 D -1 10 "0 320 CFM 36/12 L ilakE IS ©I r 'I 1 FlIEVENEWIMESIIIMINIMAIIIMEMIEN • irillIWIZI --11FL?415°0° aril 42/20 EVIE1111113rwa■N 0 , litiiik ill Er a dB)" 800 An . 120 CFM n ii 60 UP TO AIR CELL 150 150 APPROVED 01 26.01 G BUILDING 9 -96 TI #1 REVISIO F BLDG 9 -96 STRUCTURAL UPGRADE 6CALE: 1/8 = 1 ` - 0" 703445 -05 J3715225 -00 DATE 03.08 01_ 06.2901 D -1 0" 200 CF 4 TY COLD DECK AIR CELLS 8-8-96 SUBTITLE BUILDING'S 96 TENANT IMPROVEMENT BUILDING 9 -96.1 ENERAL 100 Of.150i11. 5 ' :547011100 !AUG SYM A B C D RELOCATE DIFFUSERS ADD DIFFUSER ® G -20 REVISION J# 167010 -10 JOB #180177 ADD VAV BOX JOB 100097 -00 BUILDING 9 -96 T.I. PROGRESS PRINT J #703445 5 RAD DMV DLR GROUP APPROVED RP BY DLR GROUP DLR GROUP No WORK TT ACCEPTABILITY' THIS DESIGN AND /OR SPECIFICATION. IS APPROVED, DEPT. DATE 85INELR HECKEO APPROVED APPROVED D -1 10" 4 50 CFM 3 TYP) LEGEND: 1-1 0 1 L VD i FCO AL-C- C 4L I N6i CaR \LL S, I DIFGUS S, i T etZMos o1 » ciltotz '+WAC. EQUIPMENT I N C 4 t KG lb 8E R$ 1 Vp, By p4 1 Mar s9ct FtcA LL_•( NDIGATMD• {z''CA1 N Aw TH FRMcSrAI fez .PUTURZ 12>r L OCAT1 pt.!. DUCT, SINGLE LINE CEILING DIFFUSER, ARROW INDICATE AIR THROW LINEAR DIFFUSER AND CFM AIR FLOW WALL OR DUCT MOUNTED GRILLE OR REGISTER VOLUME DAMPER ZONE & BYPASS DAMPER; VVT SYSTEM DUCT LINER; SOUND CONTROL FLOOR CLEAN -OUT PRESSURE REGULATOR THERMOSTAT; ELECTRIC RELOCATE CEILING. DIFFUSER OR GRILLE JOB NO. nwn ES: CONSTRUCTION NOTES: REMOVE CEILING DIFFUSER. 3� PRESSURE TEST EACH AIR CELL AT SUPPLY TAPS SERVING MIXING BOX. EXIST. DIFFUSERS OR MIXING BOX WILL INTERFERE WITH NEW X -BRACE LOCATION. REMOVE AND RETAIN FOR REINSTALLATION PER 1M10. EXIST. DUCTWORK CONFLICTS WITH NEW X -BRACE LOCATION. REMOVE DUCTS MINIMUM OF 7' -0" BOTH NORTH AND SOUTH OF GRIDLINE. 7 TO FACILITATE REISTALLATION PER 1M10. © EXIST. MIXING BOX AND DISTRIBUTION SYSTEM (DUCTWORK & DIFFUSERS) WILL BE IN THE WAY OF CONSTRUCTING X- BRACE. REMOVE AND RETAIN FOR REINSTALLATION IN SAME LOCATIONS. CURRENT REVISION ISYMBOL J #715225 -00I SHEET 1M13R J #715225 -00 REMOVE ALL LIGHT- TROFFER STYLE DIFFUSERS AND ASSOCIATED BRANCH DUCTS FOR THIS ZONE. EXISTING MIXING BOX AND PLENUM TO REMAIN. EXIST. DIFFUSER CONFLICTS WITH NEW X -BRACE CONSTRUCTION. REMOVE AND RETAIN FOR REINSTALLATION IN SAME LOCA11ON. REMOVE EXISTING THERMOSTAT FROM WALLS BEING REMOVED. HANG STAT ON ZONE MIXING BOX FOR FUTURE DATE 06.28.01 RECEIVED CITY P U ILA JUL 01 COMP N0. PERMIT CENTER 1 SY A B k r _ J All 200 200 —may � — — _ - i III , rt1• .iii ®r l71t� alli � • �� 1 1®1a®lima • ILm•4 ag 1®71 , 1 11 :I IF �®C ®1 �auEllIp r� r dpi iliiol®o■=Mul1� s FLiiwi�Y ∎-•■•• A 4 ...w .1 titogifilimaig or gEirlimIt _ 1W®`1 it -N, / 1 ®: = 11 . "� 1f ® 1sc ltukav 1 Ir f , �1 ®11eu,1® -iH II IlliMIIINSIMEWIEIEU llyraisllE■1N1vlrMi irli grai111 s 1.�AIMitil r I ®®•411■1S 11 11 ®1 II 1® X0):1 ■11�1� WEIlii 11 _ tli1of11�1 �I:�! 1 ®I I/® ®111: 111 ® ® ®I 1 1 MIIIIIS1111111 ®11111A:1 115 �1 ti1 1®1/11 'elgl nea;a 1'0' 1111111F ® was ai it :— C g ■�i■i� 1 �(• ®tea ®6 ®Fp ®11� ®' ism® 1 II� 70 l:�o.�3i ..mew teg , YIIY IFll!!I� ES ��� 114 _10®III 1 t , i`� Ilg9z!sz It cifI ,4i►i ►L �,e® ®®"r 'EMI I r 2217.4 I-. �Id11•I . ®laripJrlwr %' II � &j �I/ 1 O DUCT ``�, ° i`er i MN.. Lit ` ® gi■Id I v ®� l r r e- 1 f _ 1 f� / /e.L ®L 1'I IN ® TOILET IT =MN ii Q Scope of TI I FLOOR PLAN SCALE: 1 /8 " =1' -0 0110' No KO- 6 Y1pols ® 8 A -AIt0 CELL D L 265 CFM L r 3 Tl'P ,e� x24 RAG-1 7 4, 0 CFM 1��..I TYP ®.mss 36/14 90 90 '� urwri 70 D -1 10 "0 D -1 10 "0 o IHl 320 CF 320 CFM� D-1 10"0 326w5 P C 10 0 w,: ICI I 24x24 RAG -1 700 CFM 22 24 j13 IIIiIII L ®i 2112 ®( I I I 111111111 %� ■:III y yak IC 24X10 (E) 1M10 1M11 1M12 1M13 0 0 0 0 r e 1M15 KEY PLAN SCALE NONE RE— ARRANGE VENTILATION BLDG 9 -96 T.I. REVISIO PROVIDE VENTILATION TO CONF ROOM BLDG 9 -96 T.I. — PROGRESS PRINT J#167010 -12 J #167010 -14, 4703445-05 J #703445 -05 BY DMV DMV DLR GROUP DLR GROUP APPROVED RP DA1 0126.01 02:23.01 SYM BLDG 9 - 96 TI REM O J #715225 -00 BY DLR GROUP APPROVED RP DATE 06.29.01 r1C A!il'Irl'EAVAr ER I ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION, APPROVED, ROVED 60 DEPT. DATE ® ® DRAWN K.BUN CHECKED D.M.VILLA ' ENGINEER D.M.VILLA CHECKED PPROVED AP,PROVM DATE 8 - 8 -96 SUBTITLE Trr HVAC - PLAN BUILDING 9 96 TENANT IMPROVEMENT #1 BUILDING 9 -96.1 /on on LEGEND: 1 2 O I i 1 L t FCO ig 0 ALL C 1LIR & GR-IU.Vs, 1:IFFUs!I2s, TtIF -1 o5FRT5 oR- C7RIV -. ftVAc- gip• ItL' ILIIMG - tb 13? P. 4ov -p , V N 1F PDT S ?KIFIGALL"( 11 RETAIN PQ L T}161¢MOsrAt`S tzvuxAT1o1.L. N101 -12d GENERAL NOTES: REMOVE CEILING DIFFUSER. 3� PRESSURE TEST EACH AIR CELL AT SUPPLY TAPS SERVING MIXING BOX. ® EXIST. DIFFUSERS OR MIXING BOX VOLL INTERFERE WITH NEW X -BRACE LOCATION. REMOVE AND RETAIN FOR REINSTALLATION 4 PER 1M10. EXIST. DUCTWORK CONFLICTS WITH NEW X-BRACE LOCATION. REMOVE DUCTS MINIMUM OF 7' -0" BOTH NORTH AND SOUTH OF GRIDLINE. 7 TO FACILITATE REISTALLATION PER 1M10. © EXIST. MIXING BOX AND DISTRIBUTION SYSTEM (DUCTWORK & DIFFUSERS) WILL BE IN THE WAY OF CONSTRUCTING X- BRACE. REMOVE AND RETAIN FOR REINSTALLATION IN SAME LOCATIONS. CURRENT REVISION J #715225 SHEET DUCT, SINGLE LINE CEILING DIFFUSER, ARROW INDICATE AIR THROW LINEAR, DIFFUSER, AND CFM AIR FLOW WALL OR DUCT MOUNTED GRILLE OR REGISTER VOLUME DAMPER ZONE & BYPASS DAMPER; VVF SYSTEM DUCT LINER; SOUND CONTROL FLOOR CLEAN -OUT PRESSURE REGULATOR THERMOSTAT; ELECTRIC RELOCATE EXISTING DIFFUSER AS INDICATED BY ARROW HEAD CONSTRUCTION NOTES: EXIST. DIFFUSER CONFLICTS WITH NEW X-BRACE CONSTRUCTION. REMOVE AND RETAIN FOR REINSTALLATION IN SAME LOCATION. SYMBOL 1M14R JOB P0. J #715225 -00 DW.O NO n c REMOVE ALL LIGHT TROFFER STYLE DIFFUSERS AND ASSOCIATED BRANCH DUCTS FOR THIS ZONE. EXISTING MIXING BOX AND PLENUM TO REMAIN. REMOVE EXISTING THERMOSTAT FROM WALLS BEING REMOVED. HANG STA ON ZONE MIXING BOX FOR FUTURE DATE tl6 ," TU 0 06.28.01 ILA 1' 3 9001 COMPINO. II trf SYM AEVISION BY. APPROVED DATE SYM REVISION BY APPROVED DATE A RE ARRANGE VENTILATION J#167010 DMV F BUILDING 9 -96 TI #1 4715225-00 DLR GROUP RP 06.29.01 B EXTEND DUCT PER J #770448L0 DMV C BLDG 9 - 96 T.1. PROGRESS PRINT J #703445 05 DLR GROUP 01:26.01 D BUILDING 9 -96 T.I. J #703445 --15 DIY GROUP RP 02.23.01 1's � 6 "FIRE UNE ABOVE 19 eJ 000oD0000 "18x 2 REHEAT COI RH -11 4, .?'. ®fE1fLOINIII Y {.i No 1,20KK 12x6 REHEAT 4 500 CFM 1p" COIL R -5 i 2 ROUNCD� R \, DIFFUSER 2 320 CFM ® 400 D -1 10 " "0' 350 CFM 400 D 1 i'0 "0 350 CFM 1 10 "0 350 CFM 0 CFMFT D-1 10 "0 240 CFM D -1 10 "0 320 CFM 31TYP 300 CFM RAG -1 300 CFM 0 CFM 100 F� D -1 10 "0 265 CFM 3 TYP D -1 10 "0 350 CFM O ® () 6 FLOOR PLAN SCALE: 1/8"=1'-0" O (J) (K) D -1 10 "0 sown 350 CFM 2 TYP as D -1 1 I 265 CF ■51 LL ` 3 TYP '/ 4 14 ° — � 11 El w ACCEPTABILITY THIS DESIGN AND /OR SPECIEICATION IS APPROVED, DEPT. DATE DRAWN K.BUN CHECKED ENGINEER' CHECKED APPROVED, APPROVED DATE 8 -8 -96 UBTITLE' TITLE HVAC - PLAN LEGEND: 2 1 0 P101-120 BUILDING 9-96 - TENANT IMPROVEMENT #1 BUILDING 9 -96.1 2 DUCT, SINGLE LINE CEILING DIFFUSER, ARROW INDICATE AIR THROW LINEAR DIFFUSER AND CFM AIR FLOW WALL OR DUCT MOUNTED GRILLE OR REGISTER 2 LVD 2 VOLUME DAMPER ZONE & BYPASS DAMPER; WI SYSTEM DUCT LINER; SOUND CONTROL 1 FCO FLOOR CLEAN -OUT 2 2 PRESSURE REGULATOR 0 GENERAL NUILS: CONSTRUCTION NOTES: REMOVE ALL LIGHT - TROFFER STYLE DIFFUSERS AND ASSOCIATED BRANCH DUCTS FOR THIS ZONE. EXISTING MIXING BOX AND PLENUM TO REMAIN. ALL CguLI td& 2� REMOVE CEILING DIFFUSER. �RILL.(S� �1FFVS RST PRESSURE TEST EACH AIR CU_ AT - N SUPPLY TAPS SERVING MIXING BOX. OP- 188108 ® EXIST. DIFFUSERS OR MIXING BOX oVAC- WILL INTERFERE WITH NEW IN MLA t`10i X -BRACE LOCATION. REMOVE 6E AND RETAIN FOR REINSTALLATION T tb MOVt� PER 1M10. VVP 4 IF MO T SPCC C FICALa EXIST. DUCTWORK CONFLICTS M TH 11 tDIc NEW X -BRACE LOCATION. rAl - ALL._ REMOVE DUCTS MINIMUM OF 7 -0" BOTH NORTH AND SOUTH 0» lItrog.mostATS GRIDLINE. 7 TO FACILITATE 2=U+. Fu REISTALLATION PER 1M10. I LocATlot t © EXIST. MIXING BOX AND DISTRIBUTION SYSTEM ( DUCTWORK & DIFFUSERS) WILL BE IN TF WAY OF CONSTRUCTING X -B CE. REMOVE AND RETAIN FOR REINSTALLATION IN SAME LOCATIONS. THERMOSTAT; ELECTRIC RELOCATE EXISTING DIFFUSER AS INDICATED . RY ARROWHEAD EXIST. DIFFUSER CONFLICTS yr 6 NEW X -BRACE CONSTRUCTION REMOVE AND RETAIN FOR REINSTALLATION IN SAME LOCATION. ® REMOVE EXISTING THERMOSTAT FROM WALLS BEING REMOVED. HANG STAT ON ZONE MIXING BOX FOR FUTURE CURRENT' REVISION I SYMBOL [[ J #715225 -00j SHEET 1 M15R DATE, 06.28.1 U L " JOB N0: COMP NO J #715 225 - , itittVr CENTER__ SYM A RE- ARRANGES VENTILATION EXTEND DUCT PER BLDG 9 -96 T.I. PROGRESS PRINT BUILDING 9 -96 El. REVISION BLDG 9 -96 STRUCTURAL UPGRADE J #167010 -12 J #770448L0 J #703445 -05 J #703445 -05 J#703445 -05 BY DMV DMV DLR GROUP DLR GROUP DLR GROUP APPROVED RP RP 1.26.01 02.23.01 3.08.01 A®yksnrc® BLDG 9 -96 TI #1 FLOOR PLAN SCALE: 1/8 " =1' -0" J #715225 -00 BY DLR GROUP APPROVED RP 06.29 .0 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. 'DATE DRAWN K.BUN CHECKED NECKED APPROVED APPROVED DATE 8 - 8- SUBTITLE BUILDING 9 -TENANT IMPROVEMENT #1 BUILDING 9 -96.1 MECHANICAL MASTER COL A- N/27 -32 GENERAL NOTES: CONSTRUCTION NOTES: REMOVE DRINKING FOUNTAIN. TEMPORARILY CAP W, V, & CW SUPPLY. DC CURRENT' REVISION J #715225 -00 SHEEP 1M 115R JOB N0. J #7155225 -00 DWG N0. 9- 96- 1M115R' DATE 06.28.01 I I , COMP ' NO� 3 ' PEIRM1T CENTER, PART 1 - GENERAL SUMMARY A. A BOEING 9 -96 T.I. REVISION B BLDG 9 -96 STRUCTURAL UPGRADE'. J #703445 -05 J #703445 -05 DLR GROUP APPROVED 02.23.01 03.08.01 REVISION Wall Inserts: 1 Unistruts P -3200 series inserts for concrete walls. 2. Unistruts P -1800 series inserts for brick walls. 3. Unistrut P -1000 channels with P -1045 and P -1047 fittings for frame and block walls. ACCEPTABILITY THIS DESIGN AND /OR S'ECIF1CATION IS APPROVED. APPROVED BY DEP, DATE R. PETERS CHECKED APPROVED APPROVED 02.23.01 02.23.01 02.23.01 CITY 0 1.2 REGULATORY AGENCIES A. All work shall be in conformance with the requirements of the applicable codes. 1.3 SEISMIC ZONE 1.4. SUBMITTALS A. General: PART 2 - PRODUCTS C. Included in this Section are pipe hangers, pipe supports, piping expansion devices, pipe guides, and seismic restraints, and structural attachments for piping, ductwork and equipment. A. This project is located in Seismic Zone 3 Importance Factor 1.0. 2. 3. 4. B. Shop Drawings: C. Product Data: 2.1 PIPE ATTACHMENTS A. 1. Ceiling hanger attachments. 2. Equipment shop drawings, for coordination of seismic restraints. 1. Pipe hangers and supports. 2. Structural attachments. 3. Seismic restraints. 4. Sway bracing. General 1 B. Materials 2. PIPE SUPPORTS, ANCHORS, AND SEISMIC RESTRAINTS Size 1. Mechanical equipment shall include the following items to the extent required on plans or in other sections of these specifications: a. HVAC Equipment (includes only equip in ceiling, no rooftop) b. HVAC Ductwork c. HVAC Piping Detail drawings along with catalog cuts, templates, and erection and installation details for sway bracing shall be submitted. Submittals shall be complete in detail. Submittals shall indicate thickness, type, grade, class of metal, and dimensions. Submittals shall show construction details, reinforcement, anchorage, and installation with relation to the building construction. Products shall be in accordance with MSS SP 58 and MSS SP 69. Hunger material: Match piping material at point of contact with piping. a. Black steel pipe - Carbon steel, cast iron or malleable iron. b. Galvanized steel pipe - Carbon steel, cast iron or malleable with zinc coating. c. Copper tubing - Carbon steel or malleable iron, plastic coated. d. Cast iron pipe Carbon steel, cast iron or malleable iron. e. Plastic pipe - PVC coated, carbon steel. Hangers shall be sized to suit the pipe. Hangers on insulated pipe shall be sized to fit over the insulation. Manufacturer Hangers shall be Grinnell, model numbers as listed; B -Line, Michigan Hanger, PHD; Grabler; or equal. A. D. E. F. G. Manufacturer H.! 2.2 INTERMEDIATE SUPPORTS A. 2.3 STRUCTURAL ATTACHMENTS 1. Hangers shall be Grinnell, model numbers as listed; B -Line, Michigan Hanger, PHD; Grabler; or equal. Pipe Rings 1. Steel Pipe: Adjustable wrought clevis, Grinnell Fig. 260. 2. Copper Pipe: Light weight adjustable wrought clevis copper plated Grinnell Fig. CT -65. 3. Application: Use only on piping systems where axial movement from thermal expansion is less than 1 /2 ". Pipe Clomps 1. Vertical Piping: Unistrut P -1000 channel and Unistrut P -1100 series pipe clamps or equal. Copper pipe clamps for copper pipe. 2. Horizontal Racked Piping: Unistrut P -2024 series clamps for Unistrut channel pipe racks or equal. 3. Grinnell Fig. 127 U -bolts or Grinnell Fig. CT -124 Tube Straps for structural steel pipe. Pipe Rolls 1. Suspended Pipe: Adjustable swivel pipe rolls, Grinnell Fig. 174. 2. Racked Pipe: Pipe roll stand, Grinnell Fig. 271. Application: Use on piping systems where axial movement from thermal expansion is 1/2" or greater. Insulation Saddles and Inserts Hanger Rods Rod Diameter (Inches) 3/8 1/2, 5/8 3/4 7/8 1 1 -1/4 1 -1/2 Trapeze Pipe Racks Saddles: Grinnell Figure 186 -188, size to match insulation thickness. Inserts: Factory fabricated ',split type shield with galvanized steel jacket and calcium silicate insert: Mechanical Pipe, Shields, Thermal Pipe Shields, or, equal. 1. Continuous threaded rod shall be used except where otherwise noted. No chain, wire or perforated strap shall be used 2. Hot rolled steel rod, ASTM A 36; size to "Code for Pressure ,Piping ", ANSI B31.1, with safety factor' of 5. 3. Hanger Rod Size and Maximum Load: Pipe Size Load at 650 F (Inches) (Pounds) 2 and smaller 610 2 -1/2 and 3-1/2 1,130 4 and 5 1,810 6 2,710 8 to 12 3,770 14 and 16 4,960 20 8,000 24 11,630 Fabricate' from structural angles or channels or Unistrut channels to suit weight of piping to be supported. Size for minimum safety factor of 5. Steel Structure Clamps: Beam clamps, channel clamps and bar joist clips, Grinnell or equivalent. Select to suit structural system and meet loading recommendations of manufacturer. Ceiling Inserts: 1. 3" and smaller pipe, Grinnell Fig. 285. 2. 3 -1/2" and larger pipe, Grinnell Fig. 281. 3. Multiple pipes on trapeze, Grinnell Fig. 285 or Fig. 281, selected for maximum weight of 1 piping. 2.5 C. D. Where Unistrut model numbers are listed, equivalent products of Powerstrut, Superstrut or Ostrut, or equal, may be used. 2.4 PIPE ANCHORS A. B. NOT USED 2.6 SEISMIC RESTRAINTS A. B. Wall Inserts: 1. Unistruts P -3200 series inserts for concrete walls. 2. Unistruts P -1800 series inserts for brick walls. 3. Unistrut P -1000 channels with P -1045 and P -1047 fittings for frame and block walls. Except as otherwise shown on the drawings, pipe anchors shall be constructed of structural steel with all welded joints and connections. Anchor members and weld areas shall be designed to constrain all axial and rotational stresses in the piping, at the test temperatures and test pressures specified. Anchorage And Bracing of Mechanical Systems: Provide complete seismic anchorage and bracing for the lateral and vertical support of piping, ductwork and mechanical equipment as required by UBC Chapter 16 and SMACNA "Seismic Restraint Manual ", for Seismic Hazard Level (SHL) B. Coordinate seismic restraints with other 'work. Seismic restraints for suspended piping which is suspended from spring hangers shall be cable type; to avoid short circuiting the vibration mounts. Cable connector brackets shall have l neoprene', grommets. ! Connectors shall be Mason, Amber -Booth or equal. All piping, ductwork and suspended equipment shall have seismic' restraints as follows (see Sections 3.2 & 3.3 of SMACNA manual for complete text): 1. Ductwork: brace all ducts with cross sectional areas of 6 square feet and larger (oval similar), except duct on hangers within 12" of structure 2 Brace all pipes 2 -1/2 inches' nominal diameter and larger, except pipes suspended by individual hangers within 12" of structure Materials and Equipment 1. Bolts and Nuts: Squarehead bolts and heavy hexagon. nuts, ASME B18.2.1 and 'ASME 818.2.2, and ASTM A 307 or ASTM A576. 2. Sway Brace: Material used for members listed in "SCHEDULES" of this specification, except for pipes, shall be structural steel conforming with ASTM A 36. Steel pipes shall conform to ASTM A 501. Sway Bracing Cable: Galvanized steel 7 z 19 strand aircraft cable; with 'electro- galvanized steel 'swivel anchor fittings and galvanized steel cable clamps. PPROVED A. TITLE PART 3 - EXECUTION 3.1 INSTALLATION B. D. E. F. G. H. SEISMIC BRACING SPECIFICATIONS BUILDING 9 -96 T.I. BUILDING 9 -96.1 MECHANICAL MASTER All piping supports and hangers shall provide a means of adjustment for leveling, grading of piping and cold spring movements. All hanger rod lengths shall be sufficient to limit rod displacement from thermal expansion to 4 degrees from vertical Pipe rings and clamps shall be sized to pass around the outside of the piping insulation. Install vertical piping supports to allow for pipe movement due to thermal expansion and contraction. Piping shall not be hung from other piping. All elements of the support system shall be suitable for the system and shall have a safety factor of not less than 4.0 Supporting elements not specifically specified shall be provided in accordance with SMACNA and NFPA standards. Piping and heavy equipment supports, not otherwise detailed, shall conform to applicable provision of MSS SP- 58 and MSS SP -69. Where it is necessary to frame structural members between existing members or where structural members are used in lieu of commercially manufactured supports, such supplementary steel shall be provided in accordance with the AISC Specification for the Design, Fabrication and Erection of Structural Steel for Buildings. Welding of structural members, where approved, shall be in accordance with AWS D.1.1. ' HANGER SPACING FOR HORIZONTAL PIPING A. Steel Pipe: Maximum hanger spacing and minimum hanger rod diameters as follows: B. 1/2", 3/4" 1 ", 1 -1/4" 1 -1/2" 2" 2-1/2", 3" 4" pipe 6 ft. span 3/8" rod pipe 7 ft. span 3/8" rod pipe 9 ft. span 3/8" rod pipe 10 ft. span 3/8" rod pipe 12 ft. span 1/2" rod pipe 14 ft. span 5/8" rod Copper Pipe: Maximum hanger spacing and minimum hanger rod diameters as follows: 1/2 ", 3/4" pipe 5 ft. span 1" pipe 7 ft. span 1 -1/4 ", 1 -1/2" pipe 8 ft. span 2 ", 2 -1/2" pipe 9 ft. span 3 ", 4" pipe 10 ft. span Plastic Pipe: Maximum hanger spacing the manufacturer or as follows; hanger 1/2", 3/4" pipe 1 ", 1 -1/2" pipe 2 ", 2 -1/2" pipe 3" pipe 4" pipe 6" pipe 8" pipe 1 Continuous support troughs may individual hangers. as recommended by rod diameters 3/8 ". be used instead of 2. Piping shall not sag between hangers. Install additional hangers or supports at concentrated loads such as valves, when required. D.C. CURRENT REVISION J #715225 -00 SHEET M1 3 ft. span 4 ft. span 5 ft. span 5 -1/2 ft. span 6 ft. span 7 ft. span 7 -1/2 ft span h DATE 3/8" rod 3/8" rod 3/8" rod 1/2" rod 1/2" rod 5000 O JOB NO. r, 0 P NO. J #715225 -00 1 UL 1 3 2001 DWG' N0. 9 -96 -M lrrnrDTMOA SY A B C RELOCATE DIFFUSERS ADD DIFFUSER ® G -20 ADD VAV BOX BUILDING 9 -96 T.I.; — PROGRESS ,PRINT BUILDING 9 -96 T.I. REVISION J# 167010 -10 JOB #180177 JOB 100097 -00 J #703445 -05 J #703445.05 DMV RAD DMV DLR GROUP DLR GROUP APPROVED RP DATE 0x,26.01 02.23.01 SYM REVISION BLDG 9 -96 STRUCTURAL UPGRADE BUILDING 9 -96, T.I. #1 FLOOR PLAN SCALE: 1/8 ° =1' -O" J #703445 -05 J #715225 -00 BY DLR GROUP DLR GROUP APPROVED RP RP 03.08: 06.29.01 Agrawnsw ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED ROVED BY DEPT. DATE CHECKED APPROVED APPROVED TITLE MECHANICAL', MASTER 20 21 22 HVAC!L PLAN BUILDING 9-96 TENANT IMPROVEMENT # BUILDING 9 -96.1 LEGEND: 2 2 DUCT, SINGLE LINE O CEILING DIFFUSER, ARROW INDICATE AIR THROW LINEAR DIFFUSER AND CFM AIR FLOW WALL OR DUCT MOUNTED GRILLE OR REGISTER 2 LVD 2 VOLUME DAMPER ZONE & BYPASS DAMPER; VVT SYSTEM _ - -- i { DUCT LINER; SOUND CONTROL 2 0 FCO 2 FLOOR CLEAN -OUT 0 1 COL. A- N/17 -22 DC 2 AI 2 PRESSURE REGULATOR TQ THERMOSTAT; ELECTRIC y RELOCATE CEILING DIFFUSER OR GRILLE GENERAL NOTES: 1. D -1 = TITUS TMS AA, 24X24 LAY IN OR EQUAL. D-2 = TITUS MP 30 (4) 1 SLOT' 36" L RAG -1 = TITUS PAR 24''''X24" LAY -IN OR EQUAL CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING DUCTWORK IS NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MIXING BOXES ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. BRACE EQUIPMENT PER 1M13 M521 NEW DIFFUSER AND RUNOUT DUCTWORK. CAP EXISTING DUCTWORK. . NEW RETURN AIR GRILLE RELOCATE EXIST. THERMOSTAT TO THIS LOCATION. © NEW THERMOSTAT CURRENT REVISION SYMBOL J #715225 -00 SHEEP 1 J #715225 -00 JOB NO: DWG NO 9- 96 -1M13 06.29.01 COMP' N0. 2/20 36/12 ^IJ' • 18001 • E E z i/ c t l -4 D -1 10"0 3 0 ) M 27/12 27/12 I 0 ., 36/12 J i 104 ° �° '' — �, 12 1 10 ° 4 CFM ® LELi�139 ° D 1 10 " F ; n ° ,r , • 320 350 CFM 2 TYP 37/1 42/20 - _ I • /20 "':I .th mss■ Z i 12° 42 E ! ' 1 I °SI 1 � 7 O CFM j / ,. V.D. �� 320 r g 1800 1 1 i \ % v + �--^ . 11 0 " D 1 10 0 OOTYPM CFM v P �` 24A24 RAG -1 z zt /9� Li E Q 7M � y hl �2I S 0� j 1. 1 II � (_ (7) �■3 � ® 10" Di 32 GF 0 "4 .20 +'AG -1 10.0 D 1 10 "4 30TYF) I C - o /tiz i t /t 0 D -1 200 j, 1 Zl /9l 1 I I I* _ 'I 00, 0 ", CF s • 24X24 5 TYP III I NCI I L .k7±1 Z Z / ly 400 / 4 TY' 10 4 DJ1 400 CFM ©II • W • 1 ~ ^ " A MEM ZI F Ol Zq • 320 CFM � , C I' 10 °4 D -1, 390 CFM u < -- T I 74 / 10 "4 D 1, .e■ ∎� 10 ° 4 1 II un �� � i I mil■ 00 — ICI 0L 10 "4 D -1, 350 CFM r-' 0 � ? 4 0 n �� e i/ �°P� !� ci��Tl 2 �j 3/P - s1 ,.� D i -1 2 8 4 -1 7 P) / � , % 9 C . a 250 , fi ■ II II - e © � 1 35 M i I � �� 0 CFM 4 Q C__ ' ! � C M C ,, 44 IH * I 20-0 1 Ffv} CI I ' I , e'4 1� nail my pr e ; El 25 , 1 � .. e` 1 4 — n , i6 ' sw . 99® i® I I + T 1 { z (' � I f Ja ; . I ,' I a I I !� I I — � 4 1 1 L50, M I' 3,..t„-- ®3 1 e I IIF I I k I °o J�b � ���olr , ,, • 11. I ! ----1 = I � II I ® L� L _ I , , — 6EU - j % COLD ECK nEr_ n ®G�ii AIR CELLS 8'I4 - 1 I �l � 6 0 C 1 QIR Ej C M 1 ! 8 k ::JL t I I ° 5 M r SY A B C RELOCATE DIFFUSERS ADD DIFFUSER ® G -20 ADD VAV BOX BUILDING 9 -96 T.I.; — PROGRESS ,PRINT BUILDING 9 -96 T.I. REVISION J# 167010 -10 JOB #180177 JOB 100097 -00 J #703445 -05 J #703445.05 DMV RAD DMV DLR GROUP DLR GROUP APPROVED RP DATE 0x,26.01 02.23.01 SYM REVISION BLDG 9 -96 STRUCTURAL UPGRADE BUILDING 9 -96, T.I. #1 FLOOR PLAN SCALE: 1/8 ° =1' -O" J #703445 -05 J #715225 -00 BY DLR GROUP DLR GROUP APPROVED RP RP 03.08: 06.29.01 Agrawnsw ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED ROVED BY DEPT. DATE CHECKED APPROVED APPROVED TITLE MECHANICAL', MASTER 20 21 22 HVAC!L PLAN BUILDING 9-96 TENANT IMPROVEMENT # BUILDING 9 -96.1 LEGEND: 2 2 DUCT, SINGLE LINE O CEILING DIFFUSER, ARROW INDICATE AIR THROW LINEAR DIFFUSER AND CFM AIR FLOW WALL OR DUCT MOUNTED GRILLE OR REGISTER 2 LVD 2 VOLUME DAMPER ZONE & BYPASS DAMPER; VVT SYSTEM _ - -- i { DUCT LINER; SOUND CONTROL 2 0 FCO 2 FLOOR CLEAN -OUT 0 1 COL. A- N/17 -22 DC 2 AI 2 PRESSURE REGULATOR TQ THERMOSTAT; ELECTRIC y RELOCATE CEILING DIFFUSER OR GRILLE GENERAL NOTES: 1. D -1 = TITUS TMS AA, 24X24 LAY IN OR EQUAL. D-2 = TITUS MP 30 (4) 1 SLOT' 36" L RAG -1 = TITUS PAR 24''''X24" LAY -IN OR EQUAL CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING DUCTWORK IS NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MIXING BOXES ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. BRACE EQUIPMENT PER 1M13 M521 NEW DIFFUSER AND RUNOUT DUCTWORK. CAP EXISTING DUCTWORK. . NEW RETURN AIR GRILLE RELOCATE EXIST. THERMOSTAT TO THIS LOCATION. © NEW THERMOSTAT CURRENT REVISION SYMBOL J #715225 -00 SHEEP 1 J #715225 -00 JOB NO: DWG NO 9- 96 -1M13 06.29.01 COMP' N0. SYM A 8' 0 3 5 FM (10 RIOT DUCT 300 100 COLD DUCT. ■ 810 8 "0 111300 300 104 (TYP) 300 -100 (TYP) 300 D -1 10 "0 320', CFM A112 CELL 265 CFM 3 TYP 24x24 RAG -1 1' 800 CFM 2 TYP 1 800 �- 1 10 "0 . 24x24 RAG -1 700 CFM GENERAL NOTES: 1. DUCTING FROM MAN SUPPLY DUCTS TO CEILING STRUCTURAL DUCTING DOES NOT MATCH LOCATIONS FOR DUCTING FROM CEILING STRUCTURAL DUCTS TO MIXING BOXES. 2. D -1 = TITUS TMS -AA; 24"524 "LAY -IN OR EQUAL D -2 = TITUS MP-30, (4) 1" SLOT, 36" L RAG -1 = TITUS PAR 24""024" LAY -IN OR EQUAL. CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING DUCTWORK IS NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MIXING BOXES ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. - BRACE EQUIPMENT PER 1 1M14 M521 NEW DIFFUSER AND RUNOUT DUCTWORK. CAP EXISTING DUCTWORK. ® BRACE PER OR OR (�� 1M14 M521 1M14 M521 1M141M52 OR ( " 1M14 M521 1M14IM521 NEW STRUCTURAL X -BRACE IN THIS LOCATION. REROUTE EXISTING DUCTWORK AS SHOWN. ALL CELL CONNECTIONS SHOW IN NEW DUCTWORK ARE NEW. RELOCATE EXISTING DIFFUSER OR MIXING BOX © TO THIS LOCATION. INSTALL NEW DUCTWORK AS REQUIRED. (ORIGINATED FROK® ON 1M1OR.) CONNECT NEW 24 "510" AT GRIDLINE A OF 9 -90 BLDG. EXTEND TO NEW CHASE. CONT. UP. EXTEND DUCTWORK TO - NEW MIXING BOX LOCATION. NEW RETURN AIR GRILLE. REINSTALL EXIST 10 THERMOSTAT AT THIS LOCATION. CITY 1M15 KEY PLAN SOLE NONE REVISION BLDG 9 -96 STRUCTURAL UPGRADE J #703445 -05 BY APPROVED DATE FLOOR PLAN SCALE: 1/8 " =1' -0 RE— ARRANGE VENTILATION PROVIDE VENTILATION TO CONF ROOM J #167010 -14 BLDG 9 -96 T.I. — PROGRESS PRINT BLDG 9 -96 T.I. J #167010 -12 J #703445 -05 J #703445 -05 DLR'GROUP DLR GROUP DLR.GROUP 01.26.01', 02.23.01' 03.08.01 BUILDING 9 -96 T.I #1 REVISION J #715225 -00 DLR'GROUP 06.29.01 BY APPROVED DATE ACCEPTABILITY DRAWN B THIS DESIGN AND /OR CHECKED SPECIOCATION'1 IS APPROVED D.M.VILLA Nci APPROVED BY DEPT. DATE D.M.VILLA CHECKED at APPROVED APPROVED DATE 8 -8 -96 SUBTITLE` TITL cD HVAC - PLAN BUILDING 9-96 TENANT IMPROVEMENT #1 BUILDING 9 -96.1 MECHANICAL MASTER COL A-N/22-27 LEGEND: O CEILING DIFFUSER, ARROW INDICATE AIR THROW LINEAR DIFFUSER AND CFM AIR FLOW WALL OR DUCT MOUNTED GRILLE OR REGISTER 2 LV 1 VOLUME DAMPER ZONE & BYPASS DAMPER; WI SYSTEM 2 FCO 0 2 FLOOR CLEAN -OUT C CURRENT REVISION J #715 -00 SHEET JOB NO 2 DUCT, SINGLE LINE DUCT LINER; SOUND CONTROL PRESSURE REGULATOR THERMOSTAT; ELECTRIC RELOCATE EXISTING DIFFUSER AS INDICATED BY ARROW HEAD SYMBOL 1M14 EV1Y0 COMP N0. JUL 1 3 2001 J #715225 -00 DWG NO 9 econerrpnrea A REVISION RE- ARRANGE VENTILATION (A' J #167010 -12 EXTEND DUCT PER J #770448L0 BLDG 9 -96 T.1 - PROGRESS PRINT J #703445 -05 BUILDING 9 -96 T.I. BLDG 9 -96 STRUCTURAL UPGRADE J #703445 -05 J #703445 -05 BY' DMV DMV ' DLR GROUP DLR 'GROUP DLR GROUP APPROVED RP RP 01.26.01 02.23.01 03.08.01 YM , BUILDING 9-96 T.I.#1 REVISION J #71522500. FLOOR PLAN SCALE: 1/8"=1'-0" BY DLR GROUP APPROVED RP DATE 06.9.01 el__AgroAsrAw ACCEPTABILITY THIS DESIGN AND /0R SPECIFICATION IS APPROVED BY DEPT. DRAWN ' K.BUN CHECKED BUILDING 9 -96 TENANT IMPROVEMENT #1 GENERAL NOTES: 1. D -1 = TITUS TMS-AA, 24 "X24 "LAY IN OR EQUAL. D-2 = TITUS MP 30, (4) 1" SLOT, 36" L RAG -1 = TITUS PAR 24" "X24" LAY-IN OR EQUAL. DABANDON IN PLACE. CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING DUCTWORK IS NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MIXING BOXES ARE NOTED FOR BRACING, BUT VERIFY THAT. NO OTHERS EXIST. BRACE EQUIPMENT PER NEW DIFFUSER AND RUNOUT DUCTWORK. CAP EXISTING DUCTWORK. NEW RETURN AIR GRILLE INSTALL EXISTING THERMOSTAT AT THIS LOCATION. NEW THERMOSTAT. JOB N0. 1M15 M521 KEY PLAN. 0008 Y OF OOMP 1N 06.29.01 DATE - ENGINEEK CHECKED APPROVED APPROVED ATE SU BTITLE MECHANICAL MASTER, LEGEND: 2 0 2 L 2 2 a FCO 0 0 COL. A -N/27 32 DC 2 DUCT, SINGLE LINE O CEILING DIFFUSER, ARROW INDICATE AIR THROW LINEAR DIFFUSER AND CFM AIR FLOW 1 2 WALL OR DUCT MOUNTED GRILLE OR REGISTER VOLUME DAMPER ZONE & BYPASS DAMPER; VVF SYSTEM DUCT LINER; SOUND CONTROL FLOOR CLEAN -OUT 2 2 PRESSURE REGULATOR THERMOSTAT; ELECTRIC RELOCATE EXISTING DIFFUSER AS INDICATED BY ARROW HEAD CITY(±L_ CURRENT REVISION J #715225 -0O SYMBOL J#715225 -00! ATE 9- 96 -1M16'ERMITCENTtR .At - - D 7 3' 2 D 1 10 I 2 65 CkM a !DELL ' 3 TYP�'°y "0 n 0 1 T'li r 15 CF 3 M TIP) 0 D .1 I ' ��, g ; N i — .. _ a S y it Zl /SE Zt/ 1 • � ' � 0 I II � .��' - �i . �.•i }c � . � , alai _ I (6 IL_ 11 D / rV�l.e ( .1 1 •® L : t�l •� N ' 800 CFM 24x12 REG 11I 1 8 0 D 1 O1/9Z" • a ; AIR CELL ■■I�t • M � r� ICI .r s J i I n 60 gFk II t4ET Ti f C; II { I j I ' it � , —= I ; _ • 1 1J 1 � ' � u I r l I ' L - I+ $ • 11 �d� � [ � 10/ 0 �' P. - ® RAG1 I ow, i .� �T 4 . k i \ (6 TYP) �1 - / e ( I 0 D -1 10' O, v_ . E �' 24 / 7 p i /' I D, 1 10 " 0 3 C FM 17y i r11i I 1 350 CFM � ; Try gle I. I l I I . i I _ " — 12, ��, ®I ` C , fr I I 1 3 TYP i l l L it tai ,G 1 • 32Q CFM „_ I 8 1 3 0`'QF 1 .�� ` 1 ` D-1 10 "01 265 CFM 1 - u � Zl /cZ zl /tia - • " 0 0 C3 O C C ' ' 17 % - \ � NI `J 1 �� 3! T 3 P i D 1 10 "0: 3 320 C�F.b( - D r-1 10 „ 0 ` i • N t 1 T CE Q o u�10 II L � : i�® $ " � D71 ,, CFM e2 3 7� ; F cri�iiiiii 85 oin r \ . • D -? 1.0.:"0 400 \ 350 CFM"-, ._ `i 2 yI1 - 2¢5 CFM 31TYP I � N.LI p . - ri _ �., , 0 ,0 - _ 5� �G s ' , .c I © I ' I I I ' n I 11111 i 1 . I I _ II _ 1 201 i ull . �� i11 ®ID QQ CF i Al _ N - � 7 f .. ` I I ' r. I IBLANK © 1 � 4 I �v 0110111 �.�e.-.`<...�a. S ' >'; �i ' > , u 5,, 1 1 - U oo •• . ,rxn �- M I ! IUIM _:A a_ 1 . --- 7 _ IR�G 1 C FM O 1 Li L FM; I . ' 100 F -' . i f C ,R�I Z l, ® I -1 , � 0' D -1, 18x12 REHEAT COIL RH 11 ■ 1— w Ncf, WT ® M LJ � I® 2 101 - � � 1 ` 6 "1RE I I ! LINE A QVE ! � ' ! Q300 CFM ® D -1 10 "4 h; Is 90 90 A I � � �_�, X731 u 8 D 1 — i' . E /, I . 1- n 2 O =QFM f � a D Y `� 50 -1 10 "0 350 CFM CFM I' - 110 I�-�I j �- _- rl II � •�„ M � 90 1� OR a 1 3/10 I ® I ( 1 1 500 CFM 10" 1/2 ROUND 50 _ 1i 0 10 i ' • '-7o _ 33M D-1 8 j ©o r � sagra 091;4 'RAG C Q 17, II is , 27 3 a : i _ 12 f� = ', I 1 I� , I , 10 `- 11 a g , 1 1 FM f � 240 (2 GFM TYP) ;( . -12x6 R HEAT, COIL R 5 _ CF O /OZ z RAG 1 300 C � 11 RAG -1 300 CFM D -1 10 "0 - g,CFM - J IIII Y I Ii n I� 41 gl" ., �� I Fq •` of at .ya- ,':.J • 1 `G1 p FM PI � : I® ) at N -IL I � ` �� r j ��LJ _ M� [ ' ( Jf -- i - o % �i g l . DIFFUSER R',, 2'`I o 2 TYP ��`. 3 0 I� 1 11 I � . G l � ° 11 I ' :l I 1 I + �� ". i % ® i 6 " D -1 �' G ® ® G i I D 1 10 "0 240 CFM 300 CFM 300 CFM u RAG -1 300 CFM, 90 s 7 13 C'M` 1 — - - - - - � 1 KAMMIN ����tt�i� RAG ' '�- I 11 1 TYP - -1-50-GE-M - - � =0 ' J �� _ A REVISION RE- ARRANGE VENTILATION (A' J #167010 -12 EXTEND DUCT PER J #770448L0 BLDG 9 -96 T.1 - PROGRESS PRINT J #703445 -05 BUILDING 9 -96 T.I. BLDG 9 -96 STRUCTURAL UPGRADE J #703445 -05 J #703445 -05 BY' DMV DMV ' DLR GROUP DLR 'GROUP DLR GROUP APPROVED RP RP 01.26.01 02.23.01 03.08.01 YM , BUILDING 9-96 T.I.#1 REVISION J #71522500. FLOOR PLAN SCALE: 1/8"=1'-0" BY DLR GROUP APPROVED RP DATE 06.9.01 el__AgroAsrAw ACCEPTABILITY THIS DESIGN AND /0R SPECIFICATION IS APPROVED BY DEPT. DRAWN ' K.BUN CHECKED BUILDING 9 -96 TENANT IMPROVEMENT #1 GENERAL NOTES: 1. D -1 = TITUS TMS-AA, 24 "X24 "LAY IN OR EQUAL. D-2 = TITUS MP 30, (4) 1" SLOT, 36" L RAG -1 = TITUS PAR 24" "X24" LAY-IN OR EQUAL. DABANDON IN PLACE. CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING DUCTWORK IS NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MIXING BOXES ARE NOTED FOR BRACING, BUT VERIFY THAT. NO OTHERS EXIST. BRACE EQUIPMENT PER NEW DIFFUSER AND RUNOUT DUCTWORK. CAP EXISTING DUCTWORK. NEW RETURN AIR GRILLE INSTALL EXISTING THERMOSTAT AT THIS LOCATION. NEW THERMOSTAT. JOB N0. 1M15 M521 KEY PLAN. 0008 Y OF OOMP 1N 06.29.01 DATE - ENGINEEK CHECKED APPROVED APPROVED ATE SU BTITLE MECHANICAL MASTER, LEGEND: 2 0 2 L 2 2 a FCO 0 0 COL. A -N/27 32 DC 2 DUCT, SINGLE LINE O CEILING DIFFUSER, ARROW INDICATE AIR THROW LINEAR DIFFUSER AND CFM AIR FLOW 1 2 WALL OR DUCT MOUNTED GRILLE OR REGISTER VOLUME DAMPER ZONE & BYPASS DAMPER; VVF SYSTEM DUCT LINER; SOUND CONTROL FLOOR CLEAN -OUT 2 2 PRESSURE REGULATOR THERMOSTAT; ELECTRIC RELOCATE EXISTING DIFFUSER AS INDICATED BY ARROW HEAD CITY(±L_ CURRENT REVISION J #715225 -0O SYMBOL J#715225 -00! ATE 9- 96 -1M16'ERMITCENTtR SYM A REDRAWN BUILDING 9-96 T.I. #1 7-6" 8'-0" BLDG 9-96 STRUCTURAL UPGRADE ® PA hij 8 REVISION 1 300 SF OFFICE J# 4715225-00 BY KB DLR GROUP pLR GROUP 14 I7 S[144 SF OFFICE OFFICE (1 if APPROVED RP RP 7 3/4 DATE 8.8.96 03.08.01 06.29.01 2" HWS 3/8" COPPER TO DRAIN SYM V'FF 2"CONDS 2"HWS WEST ZONE ;T !! 2"HWS EAST ZONE- REVISION 3/4" HIGH PRESSURE ENDS i_j1 A ---2 CONDS 2- PUMPED CONDENSATE 0 'APPROVED FLOOR PLAN SCALE: 1/8=1-0" 14413F OFFICE 4 Yr1111 3/8" COPPER DRAIN 001"oRpNgR DRAIN (IN ITEUMr, 5"CONDS DATE r 11 Airt7EZAW ® HWS 3/8" COPPER TO DRAIN 4 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICA110N IS APPROVED , APP VED BY PERMIT SET DATE ict 1"HWR ABOVE CEUNG DRAWN 1 K. BUN CHECKED R. SQUIRES HECKED PROVED APPROVED - PA 8'-0" 05,10 SUBTITLE 8-8-96 8-8-96 TITLE 7-6" r-6- 1"HWR DN COL S-0" 1"HWR IN, ENCLOSURE TO 1"HWR AT COL FOR SIMILAR PIPING 3/8" COPPER TO DRAIN ,--1"HWR DN COL 1"HWR UP THRU SECOND FLOOR 8'-0" PIPING - PLAN BUILDING 9-96 TENANT IMPROVEMENT #1 BUILDING 9-96.1 MECHANICAL MASTER ' COL. A-N/17-22 D.0 LEGEND: CHWS CHILLED WATER SUPPLY CHWR CHILLED WATER RETURN CWS COOLING WATER SUPPLY CWR COOLING WATER RETURN HWS HOT WATER SUPPLY HWR HOT WATER RETURN STM STEAM COND CONDENSATE PMP COND PUMPED CONDENSATE A COMPRESSED AIR DW DOMESTIC WATER CGLYS CONDENSATE GLYCOL SUPPLY CGLYR CONDENSATE GLYCOL RETURN X PIPE ANCHOR PIPE ANCHOR PIPE ANCHOR RADIATOR GENERAL NOTES: 0 CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS-BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING PIPES ARE NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. BRACE PER 8 1 M 6aNL521 1M631 M521 9 10 1 M631M521 1M631M521 1M64 _ ,(2) 1M65 _ KEY PLAN, CURRENT REVISION SYMBOL ATE 1M60 h 0 1M61 1M62 M63/ J#715225-00 06.29.01 SHEET M 6 3 JOB NO. J#703445-05 1111 1 « 70111 DWG 9 ' 9-96 1 M63, REDRAWN 1 "HWS BUILDING 9 - 96 T.I. #1 CAPPED 1 "CHS CAPPED 1 "CHR 2 "HWS WEST ZONE 2"1-IWS SOUTH ZONE Fl 2 "HWS EAST ZONE 4 "CW LINE 1 "CHWR & CHWR TO FLOOR DRAIt� MEETING 3"CONDS 3/4 "HIGH PRSSURE CONDS 1 1 /2 "CONDS 3 "PUMPED CONDS 14' -0" 7' -6" SECOND FLOOR : PA 1 "HWS DN COL CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT N ORMATION. UNLESS NOTED FOR BRACING, C4 TO VERIFY EXISTING PIPES ARE NOT OF S FICIENT SIZE TO REQUIRE BRACING. BRACE PER 7 I 8 1M64 M521 1M64k1521 2 FIELD MODIFY RADIATOR HOUSING TO AVOID INTERFEREN WITH NEW X -BRACE 1M65 8' -0" 7' -6" 7' -6 7' -6' 7' -0" 7' -0" 7' -0" PA REVISION BLDG 9 -96 STRUCTURAL UPGRADE R 2" BY P L- KB J #703445 -05 DLR GROUP J #715225- OO.DLR GROUP HWS APPROVED RP RP DATE 03.08.01 06.29.01 J SYM - �I 4 "VENT 3 "PUMPED CONDS 458 SF EET1t'1G 0 . REVISION TT T I APPROVED eL ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION.. IS APPROVED DEPT. DATE DRAWN 6.• BUN CHECKED R. NGINEER CH <ED. APPROVED APPROVED • TT 8 -8 -96 8 -8 -96 ITILE 8' -0" 7' -6" 7' -6" MECHANICAL MASTER PIPING PLAN BUILDING 9-96 TENANT IMPROVEMENT #1 BUILDING 9 -96.1 COL. A- N/22 -27 LEGEND: CHWS CHILLED WATER SUPPLY CHWR CHILLED WATER RETURN CWS COOLING WATER SUPPLY CWR COOLING WATER RETURN HWS HOT WATER SUPPLY HWR HOT WATER RETURN STM STEAM COND CONDENSATE PMP COND PUMPED CONDENSATE A COMPRESSED AIR DW DOMESTIC WATER CGLYS CONDENSATE GLYCOL SUPPLY CGLYR CONDENSATE GLYCOL RETURN X PIPE ANCHOR / PIPE ANCHOR PIPE ANCHOR D.0 J. DWG N0. RADIATOR GENERAL NOTES: CURRENT REVISION J #715225 -00 SHEET 1M64 :>-40M u ATE 06.29.01 B O. J #715225 -00 far 19 NM 9 -96 -1 M64'ERMIT CENTER' SYM A REDRAWN BLDG 9 -96 STRUCTURAL UPGRADE, BUILDING 9-96 T.I. #1 REVISION 4703445 -05 J #715225 00 BY KB DLR GROUP DLR GROUP 0 ® APPROVED RP RP 03.08.01 06.29.01 SYM REVISION APPROVED DATE T T T ACCEPTABILITY THIS DESIGN AND /0R SPECIFlCAOON IS. APPROVED APPROVED BY PT. DATE DRAWN K. BUN CHECKED R. SQUIRES ENGINEER CHECKED'; APPROVED APPROVED 'DATE 8 -8 -9 8 -8 -96 BTRLE MFeHANICAI MACT012 PLUMBING`- PLAN BUILDING 9-96 TENANT IMPROVEMENT #1 BUILDING 9 -96.1 LEGEND: GENERAL NOTES: CONSTRUCTION NOTES: rnl A- N /29 -97 0 NEW 1/2 CW UNE TO COFFEE MAKER. CURRENT REVISION SYMBOL J #715225 -00 SHEEP 1M114 TE 06.29.01 JOB NO. COMP: NO. J #715225 -00 RIL 1 3 70131 DWG N0. 6 0 -0F, -1 6,1110 - REDRAWN REVISION A BLDG 9 -95 STRUCTURAL''. UPGRADE J #703445 -05 B BUILDING 9 -96 T.I. #1 4715225 -00 DLR GROUP DLR GROUP APPROVED 03.08.01 06.29.01 REVISION APPROVED ACCEPTABILITY THIS DESIGN .AND /OR SPECIFICA11ON' IS APPROVED DRAWN K. BUN CHECKED, R. SQUIRES UNGINLUK CHEC ED APPROVED 8 -8 -96 8- 8 -96 MECHANICAL MASTER PLUMBING PLAN BUILDING 9-96 TENANT IMPROVEMENT #1 COL. A- N/22 -27' D.0 JOB NO. J #715225 -00 1M114 1M115 E°:'P1 N9. 2(101 O �31 32 LEGEND: GENERAL NOTES: EWC -1 = ELKAY ERHP2 -8 WITH CORD. CONSTRUCTION NOTES: NEW ELECTRIC WATER COOLER. CONNECT TO EXIST. CW,W, &V. LONGITUDINAL BRACE NOTE: INSTALL BRACES SHOWN WIINN 4" OF HVNGER CONSRN UCIMEMBERS ED PER 5 /SI.I OR 6/S1.1 WITHOUT BRAC ROD VERTICAL HANGER LIMIT STOP EQUIPMENT EQUIPMENT ELEVATION SLACK CABLE FOR VIBRATION ISOLATED EQUIPMENT (TIP.) PLAN EQUIPMENT limpr EQUIP_ Will TOP SUPPORT POINTS ELEVATION SUSPENDED EQUIPMENT SEISMIC BRACING DETAIL SCALE: NONE 1M11,2,3,4,5, 2M11,2,3,4,5 M521 PIPE SEE UP TO 1 -1/2' 2' TO 6' BOLT SEE DOA A 1/8' S /4" 1/4 QUIP. FRAME OR / SUPPORT POINT V_iSMIC CABLE SPACE (TYP.) SCALE: NONE NOTE I. SEE SI M . BRACE. SONG TARE. FOR VFRTIGL OM; HANGERS, OWL E 8 NN EfMCES. BOLT S COECTION TO SUPPORT.* STRUCTURdE. SIDE BRACING FOR RECTANGULAR DUCTS SCALE: NONE 1M10,4;2M10,34 M521 CENTER 'BRACING FOR RECTANGULAR DUCTS 2 5 1M10,4;2M10,3,4 M521 NOTE SEE SMMN4 TABLED FOR VERIICA HANGERS. OM,UNN. BPMES, BOLT SQE, PNO CONNECTION T0 STRUCNPAL $IIPPoAT. CABLE SIDE BRACING FOR RECTANGULAR DUCTS 3 SCALE: NONE 1M10,4;2M10,3 CABLE CENTER BRACING RECTANGULAR DUCTS SCALE: NONE SCALE: NONE STRUT BRACING FOR PIPE TRAPEZE PPROVED FOR 11 1M10,4;2M10,3,4 M521 -IM521 6 BUILDING 9 -96.1 W/ TRAPEZE w /TIDE NUTS SIDE BRACING FOR RECTANGULAR DUCTS SCALE: NONE 1M10,4;2M10,3,41M521 SCALE: NONE /7O BUILDING 9-96 TENANT IMPROVEMENT # CONNC➢ON TO SUPPC SIHUCNRAL MENDER 2 M) (25.4 - 610 MM) ADD VERT. HANGERS FROM SCHEDULE WHEN 'L' IS GREATER THAN MAX. LENGTH TABLE TRANSVERSE IDNCINOMM BRACE BRACE ONE pier. SIOE OF WGT. BEM PATE CONNECTION TYPE A HRU D Yx1 /4' (75mmX6.4mm) CON ME E THRI H 443/8' (100.1mX9.5Tmm) 1 -5/8' X 1 -5/8' x 14 GA (41.3x41.31,2.0 MM) ANGLE 1/2' (12.7 MM) MACHINE BOLT TO TRAPEZE: x '10 SELF TAPPING SCREW TO DUCT. TNANSNEASE BRACE. MP% NIN ADDVERIICAL HANGERS ANGLE FROM TARE WHEN L'. GREATER THAN NUMMI LENGTH PER TPBIE SECU WfIH SON ,'SRC CVAIPS.RE 3 MA CABLE BRACING FOR PIPE TRAPEZE 4 xoTe I. BEE r BRACE smnG TABU: FoR MATCAL .ANGERS: *MGONAL BRACE, BOLT SQE @ CONNECTION TO SWPORIMG SRUCTURE TYPICAL RIGID TRANSVERSE BRACE AT PIPE HANGER n SCALE: NONE )M63,4; 2M60,1,3,4; 1M260,1,2,3,4,5 M521 2M260,1,2,3,4,5 REVISION A BUILDING 9-96 T.I. J #703445 -05 8 BLDG 9 -96 STRUCTURAL UPGRADE J #703445 -05 SCALE: NONE 1M63,4; 2M60;1,3,4; 1M260,1,2,3,4,5 M521 2M260,1,2,3,4,5 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN K. PAULSON DLR GROUP RP 02.23.01 03.08.01 TYPICAL CABLE TRAN TYPICAL CABLE BRACE' AT 1M63,4; PIPE MS A 1 2,34 1 LONGITUDINAL 63 ' BRACE 1M260 1,2,3,4,5 2M260;,1,2,3,4,5 2M260,1,2,3,4,5 REVISION elLArdwArage 02.23.01 02.23.01 SEISMIC BRACING DETAILS SYMBOL RECEIVED COMP N0. 12 1 M521 CI1Y !, U BOLT