HomeMy WebLinkAboutPermit M01-135 - HOWAT RESIDENCEM01435
Howat Residence
14714 58 Av S
City of Tukwila
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
Permit No: M01 -135
Type: B -MECH
Category: RES
Address: 14714 58 AV S
Location:
Parcel #: 868780 -0110
Contractor License No:
TENANT MRS. JOHN HOWAT Phone: 206- 242 -8407
14714 58 AV S, TUKWILA, WA 98168
OWNER HOWAT J B
14714 - 58TH SO, SEATTLE WA 98188
********************• k****** ** ** * ****** ** * ***** * *•k****** ** k* *•k ** k***** * *** k*
:Permit Description:
UMC Edition: 1997 Valuation:
Total Permit Fee:
*************• k*****************•***• k******** ** *•k * * * * * * ** * * * *•k * * ** * * * * *•k*
Signat
MECHANICAL PERMIT
REPLACE OIL FURNACE W /OIL FURNACE
Print Name :
r Authorized Signature Date
/ "2
-. _ .gez z.
(206) 431 -3670
Status: ISSUED
Issued: 08/09/2001
Expires: 02/05/2002
3,142.00
65.00
I hereby; certify that ,I have read and examined this permit and know the
same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not
The granting °'of this permit does not presume to give authority to violate
or cancel the provisions of any other state or local laws regulating
construction ;.or the performance of work. I am authorized to sign for and
obtain this:; building perm't.
Date: _2)
Title:
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or
abandoned for a.period of 180 days from the last inspection.
; . .
1 .
' • • • • •
• •• •
, CITY OF TUKWILA
"••••...
e .
Addr~e'ss: 14714 513 AV S
-Suite:
Tenant: MRS. JOHN HOWAT Status: ISSUED
Type: Ei-MECH Applied: 08/09/2001
Parcel it: 868780-0110 Issued: 08/09/2001
***".********************4******************************************4:********
Permit Conditions:
. : P. * s No changes w i l l be made to the plans unless approved by the
Engineer and the Tukwila la Building .,':.:DiviSfon:
. .
' , .
)%11 permi ts inspection records and ' approved plans shall be
available at the job site1;k1 or to the start of any con-
:struct ion. These ',documents are .:t be maintained and avail-
able until final inspection apprOVal:.:ii"i4rented.
:A11 :conttrUctiory.%0The done in conformance with approved
plans and requirements of the ,Uniford,`Building Code (1997 '
Edition) as amended ',; ifork(Mechan i ca 1 Code . (1997 Ed:IOon) ,'K
and Washington:yState - ''EnergyCode., (1997....Edi t ion) . ',, '''- ,„ '.':: •::,
:Validity : t; The::,:isSiince:-.of a., permit or approval of
plans,' 'sPe61ri cat i;ons,,, ionS! shall not be - con- .
S.iitUed a '.15eypii.;..forz, oP,i, an\ approval of , any violation
3Of' any ..ofat'fie ,:pfaixi Sfons>ots,:thebull di ng code or of any
other . Ordnheneel: 4 , - of the jurisdiction. ,, No permit presuming tOH"
giVe CY' Co violate `*.-:- the provisions of this
code Shall belhvalid. :,,,..
.-Manufacturers installation instructions required on site
;•-fi?r ibuilding Viispectors,:'revieW.;
,:•-:..,........., ..4 .z. _, :4.-.' . ".,..z,
,: hereb cprtzt.t*Si t hat I,,,, read these conditions and will comply
Witii:Sthem. OWifnetf.. Al l provisions p 'ordinances governing tiOis [r ' 1 c 1 iVii'e ;.polii with, whether:: herein or hot?;
Permit No:
M01-135
, • '
i;!- ' - ,• ', .... .. ,,, , ,,,,,,,, —.
:1 q..r 1....oki0 does not presuifie give :,iauthority 'ItO
i/10A0:,!...:it' t16 of any other Work or local law ,,,,•:.','
i3O or 010 performantp, of wpoic.s•:., •
•.•• . /,,,,..
•• • ':,. :• • J., „:,,, 0 I`
rv, :.i. ■ •'.'r '''(''
• ,, •,..,
D ate
V.77 • ,• •
1'11! •
• „ • •
• : „0:7,
• , • •7,
• •
Project Name /Tenant:
Signature: gECA,4 VL---
Valusof Mechanical E Wpment:
� X --
Site Address :
Cit State /Zip:
Tax Parcel Number: �� a /io
Property Owner:
ir1 it s . d oil A) / {o i'l/ T
y /S
CitgzZip:
i 4 m 9 e , ,
Phone: ( )
af z.,a - goo 7
Street AddressS, ,
City State /Zip:
Fax II: ( )
Contractor 0 /'' R.6 J s ys
Pho ne: `( o6 ) 7,3. ....'
Street Address : / 3 7 a4/ A.)/ 6 Q 4 t)E G ,
City pi t /t)pe
Fax #: ( ) ,,
Contact Perso 56R /i3Aig /` S
J)
Phone :� 7 ,7 6 .. 7 55
Street Address:
City State/Zip:
Fax #: (
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: gECA,4 VL---
Date: ft/ / / ei /
J
. Print name:,
Phone:
Fax #: ( i )
Address:
936,7K4,>�/& -k - 5.
y /S
CitgzZip:
i 4 m 9 e , ,
CITY OF T''YWI LA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
Project Number:
Permit Number:
MO 1 -133
STAN USE ONIY
Mechanical Permit Application
Date application accepted:
11/1/99
ouch perr
o
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT)
Description of work to be done (tease be specific):
o A/ .51 oao ,d c/s
i/ .eNf1 e&
Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of
application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor
Registration ".
Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the
:State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the
permit will be required as part of this submittal.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
'Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by
.. limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written
request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be
extended more than once.
Date application expires:
Application taken by: (initials)
✓
Submittal Requirements
Floor plan and system layout
Roof plan required to identify individual equipment and the location of each installation (Uniform
Mechanical Code 504 (e))
Details and elevations (for roof mounted equipment) and proposed screening
Heat Loss Calculations or Washington State Energy Code Form #H -7
H,V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut-
off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical
Code 1009).
Specifications must be provided to show that replacement equipment complies with the efficiency ratings
and other applicable requirements of the Washington State Nonresidential Energy Code.
Structural engineer's analysis is required for new and the replacement of existing roof equipment
weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be
stamped by a Washington State licensed Structural Engineer.
6E1 .•i OM
. 11/2/99
nllsc,UHl.doc
Mechanical Permits
COMMERCIAL: Two complete sets of drawings and attachments required with application submittal
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced.
ESIDENTIAL: Two complete sets of attachments required with application submittal
Submittal Requirements
New Single Family Residence
Heat loss calculations or Form H -6.
Equipment specifications.
Change - out or r placement of existing mechanical equipment
to be done, including modification to duct work.
Installation of Gas Fireplace
Narrative with specification of equipment and chimney type.
If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe
condition:
NOTE:. Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced.
4,i,44'4.***44'.*4. *
, 07YOFT/i !MLA :WV' .: . TRANSMIT
:*,',koill *****
1,41ARSMX. 01010 A m ou n t : . 65.00 08/09/01 13:31
P00*ItNettiod r, -CHECV. ,Notation : ROSSOE In it: KAS
, .
• .,• , , .,
Pern it No: M01-135 Type: 13 -MECH MECHANICAL PERMIT
Parcel Na: 860780-0110
te Address: 1471 5V "" S
Total Fees: 65.00
s payment 65.00 Total ALL Pmts: 65.00
Pal ance: .00
*********************A**************o.******4*+*************
Ac Code Description Amount
000/aA5.83o PLAN CHECK - RES 13.00
000/32'2.100 MECHANICAL - RES 52.00
•-• - •
7OO6 08/10 9710 TOTAL 65.00
CITY OF TUKWILA BUILDING DIVISION y7- "sr- ^r^ *77 `
INSPECTION RECORD ' •
Retain a copy with permit
INSPECTION NO.
6300 Southcenter Blvd, #100, Tukwila WA 98188
Approved per applicable codes.
PERMIT NO.
',(206)431 -3670
Pr ject:
Ii
s '..
Special instructions:.
e of Inspection:: ..
D t 'Tel
Requester:
1•-t rs
a
14ou oL-k'
.Phone:
.90t9
Corrections required prior to approval.
COMMENTS:
6►
r r` a l f ro duff
n $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Inspector:t"
Date: f( i-- 0 )
Receipt No:
Date:
tt asitd ' '.24z .' -'BENS''♦`S b' "' k.r.S Ws ik +'f G`tin:t�aui:n'.µ'+ar.•t .•.Li+cs:
g
0
2 W;
W } o
J;
u- <
N D:
W.
2 ;
U
O co
0 I—
W WI
O
u
U E .
O~
z
MODELS
HIGHBOY
COUNTERFLOW
HORIZONTAL
MUUFL NO '
_ 111U PURIM INPUT
R1U PI R I IR OUTPUT AT
t10N r'
0H2 -56'
•; 70.000
56.000
52"
OH3 -72
90.000
72.000
56"
0115.85
106.250
85.000
56"
OH11 -105
. 126.000
101.000
59 -1 /2"
01116.125
OC2 -56'
70.000
56.000
57 -1/2"
005 -85
OT5.85'.
OT11 -105'
0716 -125'
en
'
156.250
125.000
66"
106.250
85.000
106.250
85.000
126.000
101.000
156.250
125.000
56"
_ 20 -1/2"
24"
26"
_ 111 it ;111 Of CASING
Y11I)III Of CASING
19"
22"
24"
24"
27"
19"
24"
_ 68"
74"
74"
(111'11101 CA`;ING
27"
30"
33"
34"
36 -1/2"
27"
33"
24 -1 /2"
24 -1 /2"
26"
WARM AIR OUTLET'
17" x 17"
16" x 16"
22" x 20"
22" x 20"
22" x 22"
17" x 17"
20" x 16"
18" x 16"
20" x 20"
22" x 20'
O
HI 1 URN AIR INLET
20" x 16"
20" x 16"
25" x 16"
25" x 16"
25" x 16"
17" x 17"
22" x 20"
18 x 16"
20" x 20"
22" x 20"
111n (11 f 1.0E OUTLET
1 1 ()Olt (. FNTER OF FLUE
i ANt LARD HORSEPOWER
I'
5"
TOP
1/3
1/2 - SP
6"
TOP
1/3
1/2 -4 SP
6"
TOP
113
1/2 - SP
6"
TOP
113
7"
TOP
112
3/4 -4 SP
5"
70P
1/3
6"
TOP
113
- _ 6"
6"
r
__ 8.1/2"
12'
13"
1/2 -4 SP
1/2.4 SP
1/2 -4 SP
1/2 -4 SP
1/2 - SP
3/4 - SP
�.. 1:111.1 g02&05WC
02
0.5
0.2
I'5
0.2
05
02
0.5
0.2
0.5
0.2
05
0.2
05
02
05
02
05
02
05
B
1050
850
1120
970
1157
970
1525
1150
1679
1358
1100
875
1210
1100
III SPEl r1
MII -SPE
MI .Sl'F Fl)
I O SPEED
El
130
DD
1371
1172
1113
876
1700
1500
1619
1385
2285
2077
1229
963
1504
1349
1504
1307
1596
1408
2237
2062
1120
992
997
770
1400
1262
1360
1181
1949
1768
1067
845
1207
1100
1295
1130
1329
1162
2020
1897
916
734
801
608
897
728
685
585
1118
891%
1025
777%
1122
89111
1022
81511
1641
1363
1535
1255
840
721
962
873
1064
1069
940
1877
1789
714
600
7710
6670
859
751
863
742
'
A/(: CAPACITY STANDARD
MOTOR
B
2 TON
2 TON
2 TON
2 112 TON
3 112 TON
2 TON
2 TON
UU
3 TON
2 TON
3 112 TON
3 112 TON
5 TON
2 1/2 ION
3 TON
3 112 TON
3 1/2 TON
5 TON
A /(. I:APACIT V WITH MOTOR
UPGRADE
B
2 112 TON
2 1/2 TON
4 TON
4 TON
5 TON
2 1/2 TON
4 TON
DD
4 TON
4TON
31/2 TON
4 TON
APPROX TEMPERATURE
RISE
B
70
70°
70
70
70
70
70
DD
70
70
70
70
70
70
70
70"
70
70
NC`' ?t E SIZE SPRAY ANGLE
PA TERN
11 =11()1 LOW
S =SOLID
UR
0.55
0.65
0.75
0.90
1.25
0.55
0.85
0 75
0.90
1 25
SW
0.50
70 ° H
0.65
80 ° H
0.75
80 H
0.90
800H
1.10
80
0.50
70,-,H
0.75
80 H
0 75
80
0 90
80
1 10
80 H
''O AND SIZE OF PERMANENT
FILTERS
ONE
16"x20"
ONE
16 "x20"
ONE
16 "x25"
ONE
16 "x25"
ONE
20 "x25"
TWO
10 "x 17"
TWO
12 " x20"
ONE
16 "x25"
ONE
20 "x25"
ONE
20 "x25"
FILTER RACK FLANGE
DIMENSIONS'
19 -1/2" x 15"
19 -1/2" x 15"
24 -112" x 15"
24 -1/2" x 15"
23 -1/2" x 19"
N/A
N/A
N/A
N/A
N/A
APPROX EFFECTIVE HEATING
SURFACE
APPROX. SHIPPING WGT.
SEASONAL EFFICIENCY
2721.6 SQ.IN.
300 LBS.
80.7%
3320 SO. IN
365 LBS.
78.1%
4650 SO. IN.
410 LBS.
80.6%
5300 SO IN
490 LBS.
80.0%
7400 SO IN
2712 SQ. IN.
4650 SO. IN
4570 SO. IN
365 LBS.
82.1%
5500 SO. IN
7400 SQ. IN
500 LBS.
78 0%
546 LBS.
81.2%
305 LBS.
81.0%
420 LBS.
83.3%
445 LBS
78 2%
1A11 sI MODELS HAVE EXPOSED BURNERS T.UNITS NOT FOR ATTIC INSTALLATION
ON All O(ITL F T AND INLET DIMENSIONS. THE FIRST DIMENSION IS WIDTH
' 1((1 ::E UNITS ARE EQUIPPED WITH A HIGH MICRON FILTER AND CANISTER FOR OIL LINE FILTRATION
MAX CAM USING STANDAR( iUPPLIED -FOR HIGHER STATIC RESISTANCE IN DUCT SYSTEM. A LARGER
MOIOR MAY BE REQUIRED
• NOT RI (.I NmMENDED FOR LOW SPEED
' SPF E C`YIOT RECOMMENDED FOR HEATING
OIL FIRED FURNACE SPECIFICATIONS
` SUBSTITUTION OF A LARGER MOTOR AND /OR ALTERING nit I'Ut LEY RATIO WILL RESULT IN HIGHER CFMAND PERMIT
LARGER AIR CONDITIONING CAPACITY
BTU OUTPUT BASED ON E0': EFFICIENCY, PATE BY UANUFACTUPFP All SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
SEASONAL EFFICIENCY (ALSO CALLED ATUE- ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS
FOLLOWING U S DEPARTMENT OF ENERGY TEST PROCEDURES
' ALL MODELS IN CHART ARE U L LISTED
- UR = UL RATED "' SW = SHIPPED WITH
NOTICE: IF THE DOCUMENT IN THIS. FRAME IS LESS CLEAR THAN
THIS NOTICE IT TO THE QUALITY OF THE DOCUMENT.
MO105B
140.MI 8/99
MODELS
LOWBOY
MODEL NO.
012 -56'
015 -85
0111 -105
0116 -125
0120 -151
0133 -200'
0137 -250'
' 0139320'
BTU PER HR. INPUT
70.000
106.250
126.000
156,250
185.000
250.000
312.500
400.000
BTU PER HR. OUTPUT AT
BONNET
56.000
85.000
101.000
125.000
151,000
200.000
250.000
320.000
HEIGHT OF CASING
34 -3/4"
43 -1/4"
46 -1/2"
46 -1/2"
50 -1/2"
60 -3/4'
67 -3/4'
67 -3/4"
WIDTH OF CASING
19"
25"
25"
27"
27"
34'
38"
38"
DEPTH OF CASING
48"
50 -1/4'
54 -1/2"
58 -1/2"
58 -1/2"
72"
85 -1/2'
85 -1/2"
WARM AIR OUTLET
17" x 17'
20" x 20'
20' x 20'
22" x 22"
22" x 22'
28" x 28"
32" x 32'
32' x 32'
RETURN AIR INLET 2
17" x 17"
20" x 14"
20" x 16"
22" x 18"
22" x 18"
28" x 24"
32" x 28"
32" x 28"
DIA. OF FLUE OUTLET
5"
6'
6"
7"
7"
9"
9"
9"
FLOOR- CENTER OF FLUE
29 -1/4"
36"
38 -1/2"
40"
44"
51 -3/4"
59"
59"
STANDARD HORSEPOWER
B
1/3
1/3
1/3
1/2
1/2
1/2
3/4
1
DD
1/2 -4 SP
1/2 -4SP
1/2 -4SP
3/4 -4 SP
3/4 -4 SP
CFM @ 0.2 & 0.5 W.C.'
0.2
0.5
0.2
0.5
0.2
0.5
0.2
0.5
0.2
0.5
02
0.5
0.2
0.5
0.2
0.5
mgg
1040
750
1157
970
1525
1150
1702
1410
2073
1516
2315
1920
2893
2410
3700
3350
HI- SPEED
MH -SPEED
ML -SPEED
10-SPEED
1455
1241
1726
1493
1728
1506
2239
1962
2177
1885
1197
1049
1320
1213
1353
1249
1799
1606
1699
1516
DD
957
875
1066
983
10601
9881
1477
1346
1390
1269
DD
768
685
8481
7644
8451
7591
1178
1077
1117 1019
A/C CAPACITY STANDARD MOTOR
B
2 TON
2 TON
2 TON
31/2 TON
5 TON
5 TON
5 TON
8 TON
DD
3 TON
3 1/2 TON
3 1/2 TON
5 TON
5 TON -
NC CAPACITY WITH MOTOR
UPGRADE
B
2 1/2 TON
4 TON
4 TON
5 TON
10 TON
10 TON
10 TON
DD
4 TON
4 TON
APPROX. TEMPERATURE RISE
B
70
70
70
70
70
70
70
70
DD
70
70
70
70
70
NOZZLE SIZE SPRAY ANGLE
PATTERN
H= HOLLOW S =SOLID
UR"
0.55
0.75
0.90
1.25
1.35
2.00
2.50
3.00
SW"'
0.50
70 H
0.75
80 H
0.90
80° H
1.10
80 H
1.35
80 H
1.75
80° S
2.25
80° S
2.75
80° S
NO. AND SIZE OF PERMANENT
FILTERS
ONE
16" x 20"
ONE
20" x 20"
ONE
20" x 25"
TWO
14" x 25"
TWO
14" x 25'
"TWO
2 "x20 "x25"
"FOUR
2 "X16 "X20"
" FOUR
2 "X16 "X20"
APPROX. EFFECTIVE HEATING
SURFACE
3038.4
SQ.IN.
4850 '
SQ. IN.
5500
SQ.IN.
7400
SQ. IN.
7525
SO. IN.
12,000
SQ. IN.
16.000
SQ. IN.
16.000
SO. IN
APPROX. SHIPPING WGT.
315 LBS.
410 LBS. •
500 LBS.
560 LBS.
600 LBS.
1025 LBS.
1120 LBS.
1150 LBS.
SEASONAL EFFICIENCY
82.8%
82.0 %'
81.6 %'
80.0%
81.1%
N/A'
N /A'
N /A'
ON ALL OUTLET AND INLET DIMENSIONS. THE FIRST DIMENSION IS WIDTH
' THESE MODELS SHIPPED KNOCKED DOWN - ALL OTHER UNITS ASSEMBLED
• THESE UNITS ARE EQUIPPED WITH A HIGH MICRON FILTER AND CANISTER FOR OIL LINE FILTRATION
▪ SPEED NOT RECOMMEND EATING
. WHEN PROVIDED WITH OP .. RIELLO BURNER 015. 85M =860% AFUE. 0111 -105M =826 %AFUE
' MAX CFM USING STANDARD MOTOR SUPPLIED - FOR HIGHER STATIC RESISTANCE IN DUCT SYSTEM. A LARGER
MOTOR MAY BE REQUIRED
UR = UL RATED
- SW = SHIPPED WITH
OIL FIRED FURNACE SPECIFICATIONS
Thermo Pride
' SUBSTITUTION OF A LARGER MOTOR AND /OR ALTERING THE PULLEY RATIO WILL RESULT IN HIGHER CFM AND
PERMIT LARGER AIR CONDITIONING CAPACITY
'BTU OUTPUT BASED ON 80% EFFICIENCY RATED BY MANUFACTURER ALL SPECIFICATIONS SUBJECT TO
CHANGE WITHOUT NOTICE
' SEASONAL EFFICIENCY (ALSO CALLED AFUE- ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON
TESTS FOLLOWING U S DEPARTMENT OF ENERGY TEST PROCEDURES
' DEPARTMENT OF ENERGY TEST PROCEDURES DO NOT REQUIRE TESTING ON UNITS WITH 200 000 BTU INPUT
OR HIGHER
.$ ALL MODELS IN CHART ARE U L LISTED
OL33.37,39 HAVE DISPOSABLE FILTERS
NOTICE: IF THE DOCUMENT IN THIS. FRAME IS LESS CLEAR THAN
THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT.
M0105A
ECN 4110 -Mt 8199
F62 (81971
DEPARTMENT OF LABOR AND INDUSTRIES
REGISTERED AS PROVIDED BY LAW AS
CONST CONT GENERAL
REGIST.4- EXP. DATE
CCOi ROSSOES10111 09/30/2001
EFFECTIVEtDATE. 06/13/1990
ROSSOE ENERGY SYSTEMS INC
A l PO BOX 18259
SEATTLE WA 98118-0259
". • • • • • •
.
I