Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M01-138 - SEGALE #981 - SHOP
M01438 Segale #981 Shop 5811 Segale Park Dr C EX 'RED APR 22 2002 : ' - • 1 ... City of TUkvvZIc1 (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M01 -138 Type: B -MECH Category: NRES Address: 5811 SEGALE PARK DR C Location: Parcel #: 352304 -9018 Contractor License No: FIVESM *010JT TENANT SEGALE #981 SHOP Phone: 5811 SEGALE PARK DR C, TUKWILA, WA 98188 OWNER LA PIANTA LTD PARTNERSHIP Phone: (206) 575 -3200 PO BOX 88050, TUKWILA WA 98138 CONTACT RICHARD R. GARCIA Phone: 206 - 786 -8894 3901 WEST VALLEY HY N #200, AUBURN WA 98001 CONTRACTOR FIVE STAR MECHANICAL Phone: 253 -833 -8284 3902 W VALLEY HY STE 200, AUBURN WA 98001 * ***** pit ** *•*********•k * * *** *** * * *** sir** * *** k* ** k k *** k•k•k k k** k* *** k k k k* k* k* *•k* ** Permit Description: INSTALL 48K BTU FURNACE AND AIR DISTRIBUTION CONSISTING OF 4 SUPPLY GRILLS AND 1 RETURN GRILL. UMC Edition: 1997 Valuation: Total Permit Fee: * * ** k 1 ***i************************************ k * * * * *•k * * * * * *•k * * * *k * *•k * * * * ** Permit g nter Authorized Signature MECHANICAL PERMIT Date Status: ISSUED Issued: 08/21/2001 Expires: 02/17/2002 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied ith, whether specified herein or not The granti of this permit ••es not •resume to give authority to violate or cancel the p o s on •f any other state or local laws regulating construction c e it an of wo'k. I am authorized to sign for and obtain this Signature ' • Date: _/Z—CO b I Print Name:T irLt› Title: 3,800.00 56.94 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Address: 5811 SEGALE PARK DR C Suite: •Tenant: SEGALE *981 SHOP ! Type: B-MECH Parcel #: 352304-9018 ignature: rint Name: 642-1 .CITY OF TUKWILA Permit No: M01-138 Status: ISSUED Applied: 08/15/2001 Issued: 08/21/2001 :..-.4**********************4*************************************************** t ts tt!.i. t Conditions: f. :Plumbing permits shall be obt e aind_through the Seattle-King l''SCOunty Department of F'Ukr,1 w i l l be . - . • inspected by that :ageny4•--including a 11-, gas ..', (296-4722) . .Electrical per41:4"' Sha 1 1 be obtained through the T;Washington :' wi 1 1 be ' by that agency (248-6630) .1, : State Di visionSf ;Labor and', tnd,ust,rieS, and al 1 e l'eptri ca 1 • . ...,. No change wi 1 1 made to the plans ' unless approved bY., the i„ , , E n g 1 p e e g r n c l tl)Pau kw it B u i l d i n g D i v i s i o n . _ .,.'1':;':',.' :,,,•!-',',,,, 4.. Al l , pepoqts e ynifie,o101..),,re,cOrds, ,,,, and approved plans shall be i'a i 1 ali1 at the job 'Site prior to the start of, any con - ''',,': •:,...: ,::., structlon.. These " are to be maintained and ayOl aii 1 e4Oiti'f'.' inspection approval is granted. 5. :1A11 tei vi ti conformance with th aPprOVed ::ir..;.,*: - ; i ' : , : : , . • :.,: p 1 ails andtreciul remen,ts orm : Bu i 1 d i ng Code (19, :::'.i, . . : - . : ' , • : - E i d f i t : y e i ) • as a lie n d ed ;'...14,0,Troriii , Pod e, 1997 ' E d i t i o n ) ! ”:4. andNastilngtoli State Energy. Code (1997 Edition). 6.'".Validity of :Permi t. The issuance ofa ,peitinft .- br., approva ', . f;Speeifloat ions ,., and:,.comPtitatiOnS?: nOts be con- .. L-;:strItf,ed :t9 '-be ,a permit for, ,..or ,an apprtiVa 1 Of, ," .any,-v 1 . , , • of any . 1',of the. provi s ions- he ; building code or , of, any ck l 1.er‘ or pAnce o .. e -3ur..,,. sdic,t ion. • ;tido'. permit presuming to ,,- ..g authority to ,violate b P , cancel the provisions f rpVisions,:oj? this -,., , codvshall, valid. ' ., , ._, 7:.i,Mailti.f4ttirerS installation istriidttons required on site ,. for the ObIlding' reyfew. 1 he 6 read . es . p„ .. ,..sondi t i op* and'....$y comply . )tir: Al ViRrovis oils of. law and ordinance 1 n g 6.i'''10',6i-1, w i 1, complied w ith, t,''!.!.1.,-110: .:..specified!-0erelbrnot '-'::,',. , :si:. , .:,':. ....- ' .,- . . - . ‘;:!..!,:,-;,!:,,, , ,,i,, . ...,:i' ,,..., 3, - ,, . :,... ,:: ,-, ,' • .„.- Ilie Orpliti ng :01$. .:perpt 416iate.."-orf.ca eel t6( -o regulating C. ' t ating s ct o ,-- • .„., oes not -presume to gt‘re authority to isions of , ny laws " work or '166a perf0 'mance of ' work. Date: 0 0 co 0 w w w 0 2 g < (1)21 w z uj RC] X CO - CI U. la w z 1= 0 " Project a 8 \ S t os Name/Tenant: , VT I—s ‘ d Value of Mechanical Equipment: 3 a • pd Site Address : City State/Zip: c TUK. Wd Tax Parcel Number: SeriPda VAie--1 P '-t r'e Property Owner: P1e441 -b. 1r1 04 vrelp P.142-' 1 P f Phone: ( 20,6 ) X15 2 a o C, Street Address: P. 0 . C$02.8 - Cu ■-, ■l` City State/Zip: 9s 13, Fax #: ( ) Date: $ / Contractor: ¶t s'rb4L• NECH k.ltt Cis- L- Print name: Phone: (215$) g3 • 8264 Street Address: City State/Zip: 3q0 '2- 4.1. N)►t -may tkwy a • 200 rTU�W ft.N. W A cii,o©1, Fax #: ( J Phone: (zt Contact Person: 'IZ -Lckl .41-r) Sa- -G-c-t. - • Phone: ( •ynt") -t e1-.lo $$4•ii- Street Address: • 3c102 W . YA►,.0 N w ( 200 ci I5o c I �B�ICD111i`Gt` NE r 4 A` f t �5 i'4;t Vic? �: .7� t I ...�, f, :1;'`-..? +Jti S I, . � �':. �., � � � ... t ! r n ,,,,,...�• �' + � ?� �'� � ! + ' !y .M t• � ri�r r +”' „ ' i:r +.*1 ... ! ae j. i� 1 � ,il'QENI�.Ii � { +. .� „'��i'h�:� ,,..�t Signature: A)------\. Date: $ / o - t Print name: Phone: (zt Fax #: (-----) Address:, 3`102 4 A -�wEy IWy ►•� Zoo City/ State/Zip: ....46u1244 knits t I ANIVINIONIMonsu Mechanical Permit Application i i � h;i � M ll 1F1 2 M# JMFtl k .li 1' T 1� "' .A� 4•ii lA ' ;u;:,:r..,yias;�y11Eil'j- , IdPEhINITtREVIEtAi.► ND: APhRQVAL' REQUES7fED ;(lOBEF /tLEL)OUTBYi/`PPL %CAN Description of work to be done (please be specific): k I- Vb.LL 48 VL 1--W .ill Lo IS4:. l Cs ©F A s t9 P f' `--`-1 tgru LLS ...1.4.1b 12.-- e- & 1 LI - • Current copy of Washington State Department of Labor and. Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AN MINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PER JURY BY THE LAWS OF T STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: a -is- v Application taken by: (initials) W2/99 meek pemb.doc CITY OF T 'KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. CITY OFETUKWILA AUG 15 2001 PERMIT CENTER r - ..—+1 ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -15 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. , a 'fit. ,� • Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal RESIDENTIAL: Two complete sets of attachments required with application submittal 9/21/99 • miscpnu.doc ;NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Submittal Requirements ew Single Family Residence Heat loss calculations with specifications or Fora H - 6. Change - out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition: NOTE :. Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. i ,: p .y roe rit 1 r +r�Y.j:1t A1*: E****• kA*A 0% A** 14***:**:. * * * * *kAhA * * *+**i * *** * * * * *** * * ** .IiY G TUKW1LA... WA. . ', ' TRANSMIT *-.4 4. *Ark'* r 1k *** *A *4:* *A *yl';4 *'k* k *A * *A * ** h * * * * * * * *A ** *k* * * * *A * * ** •f ` NaMIT' :,;Nu,mber : 80.1010£3.4 Amount: 56.94 OS/21/01 1E, :53 Pavrent Me.tbod. :: Natation: FIVE STAR MECH Init: SKS e00t` No 'M0t -1Si3 Type: B-MCCii MECHANICAL PERMIT. arc'e1 'Mo:. 3 2 iO4 -x.018 y -;be `.Address 811, ,"!GALE' PARK DR C • Total Fees: 56..94 Total ALL Pmts: 56.94 Balancer .00 .4!,* *** *. *w * * *' * * * * * *40i,( * ** * * * * * * * * **A* * * *A** • * ******* * * ** ccau.'nt :Code De4cri p t i on 'Amount ,0.0 / a;4j« : B aQ PLAN CHECK -- NOMRES 11.:39 t)0/3221'�00 MECHANICAL NONRES 45.55 0346 00/23 • 77i6 TOTAL 56.94 Project: Type of Inspection:,' Address: 5g 1 I Seu ; PkDr.� Date called: - 1 o•))-61 Special instruct ns: 3 Date wanted: /6 a.m. p.m. Requester: a4 6C) Pho e b 6 _ 786 - gg4 Z INSPECTION RECORD'"` . Retain a copy with permit` INSPECTION NO CITY OF TUKWILA BUILDINt! DIVISION 6300 Southcenter Blvd; #100, Tukwila, WA 9818 PERMIT NO. (206)431 -3670 Approved per applicable codes. gCorrections required prior to approval. 4. Date: Ei $47.00 EVEQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., ulte 100. Call to schedule reinspection. Receipt No Date: W , § ; 9 . r- O Z n 0 w o H' W t .. z , U tA: Z .Project: .. •e61e -# c8i' T e 'of Inspection: ' K 'TO .inr5u.L d ••: • c Iled: sp j1o1 D nted: � Z�ii � F::: . p.m. . Special instructions;,''• •• Register: 1 tj at a rd---- r.r \ ""Q"'^ .A * ,., T+7M �! ',.n'7 C 7 'p • T - '.a... —•?.. .-.y f S Q1 INSPECTION NO. / INSPECTION RECORL$ Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION ,,, 6300 Southcenter Blvd, #100, Tukwila, WA ;981 Approved per applicable codes. PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: 4 ' v C C+ Q _ +0 So144 Date: 8_ ) $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: c ...: J✓. v... . t 3 �x � : . � 'b..y r ". : :a .. •n!+:nY. a `14;ediet+,, + JM1�AIU' 1. Y�Yf4 .1t4f'.Z"«4 "�.�L.b.e'Rf1 "�- - ;� NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. C:::) • • • DEPART N11 I ;1 ( )1:1.ABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST COWT GENERAL dcol EFFECTT VV T$T# EXP..DATE c1 E DATE • -. 04/30/1999 FIVE STAR MECHANICAL 3902 W VALLEY HWY N STE 200 AUBURN WA 98001 NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. _ April 4, 2002 Dear Permit Holder: City of Tukwila Department of Community Development Mr. Richard Garcia 3901 West Valley Hy N. #200 Auburn, WA 98001 RE: Permit Application No. M01 -138; Location: - Segale 981 Shop 5811 Segale Pk Dr. C In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to schedule a progress or a final inspection A progress inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicant's control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to April 21. 2002, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Kai L 4 6 , z - nCW Kathryn A. Stetson Permit Technician Xc: Permit File No.M01 -138 Bob Benedicto, Acting Building Official Steven M. Mullet, Mayor Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 - 3670 • Fax: 206 431 - 3665 It • W } o [ • IL Q : . rn � lauf • t-r V t] w — 01— W O1 I .. Z : N •O i DEPARTMENTS: Building Division C ' e' I b-or Public Works Complete TUES /THURS ROUTING: Please Route \PRROUTE.DOC 5/99 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M01 -138 DATE: 8 -15 -01 PROJECT NAME: 981 SHOP SITE. ADDRESS: 5811 Segale Pk Drive C SUITE # Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DETERMINATION OF COMPLETENESS: (Tues., Thurs.) APPROVALS OR CORRECTIONS: (4 weeks) j /C s Fire Prevention Zi'1 -o Stru rural Approved n Approved with Conditions Incomplete n Not Applicable Comments: Structural Review Required REVIEWER'S INITIALS: DATE: REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved Approved with Conditions Li REVIEWER'S INITIALS: Planning Division Permit Coordinator Kj DUE DATE: 116-01 No further Review Required DUE DATE 9 -13 -01 I I Not Approved (attach comments) DATE: DUE DATE Not Approved (attach comments) DATE: `4 ( File: 0 I ---- I 3 35mm Drawing# • / FIL _ E COPY I understtand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt . con - tr>a ctpr's, c. y of, r d p By Date e' Permit No. . 140 1 5Ib EVIS PRI HO CHANGES O';' CF ',:CORK � ®0RI '� ®� axe @ �,AY 11i �o � OF It) 11 WONG �� � �� I� FEES. wSEPARJT : a :.RI' IT REQUIRED FOR: 0 MECHANICAL OKLECTRICAL PLUMBING GAS PIPING CITY OF TUKWILA BUILDING DIVISION 4t'pRo\ t:D p,u N 1 e i! i t.- 91• hl. Cl. Zi. XE 80 XE 80 TUEJTDE :• _. .'vil OEN ;'EC, TPANE `, r ; Ui' . I L. Unit Model No. TDD04OC924E TDD060C924E TDD060C936E TDD080C936E TDD08OC945E TDD100C945E TDD1000948E TDD1000954E TDD120C954E TDD120C960E TDD140C960E Table 36 - A - Unit Model No. TUD040C924J TUD040C930J TUD060C924J TUD060C936J TUDO80C924J TUD080C936J TUD080C948J TUD100C936J TUD100C945J TUD100C948J TUD100C960J TUD100C972J TUD120C954J TUD120C960J TUD140C960J Table 36 -B - Table 36 -C - Unit Model No. TUE040A924K TUE060A936K TUE080A936K TUE080A948K TUE100A936K TUE100A948K TUE100A960K TUE120A960K TUE140A960K r l I I - I r - I I . I , i . - I I1 -,. i11 111 1 I l i111 0 INCH CHINA I�I�I 1I I11j jI�1 -1fI� . I iTIT i, 1111 11111 6 l 11i111111 JEHI11 th i II i1111111111 XE 80, Electronic Ignition Convertible Gas Furnaces XE 80 Single Stage, Upflow /Horizontal Left or Right Induced Draft Gas Furnace (115/1/60) Airflow Nominal Flue Uncrated Shipping In Output ICS® Size Ignition. Dimensions (in.) Weight Max Filter Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes 2 32,000 . 80.0 4 Silicon Nitride 40 x 14 x 28 119 15 17 x 25 x 1 2 32,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 122 15 17 x 25 x 1 2 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 124 15 17 x 25 x 1 3 47,000 80.0 4 Silicon Nftride 40 x 14'/2 x 28 127 15 17 x 25 x 1 2 64,000 80.0 4 Silicon Nitride 40`x 17 x 28 139 15 17 x 25 x 1 3 63,000 80.0 4 Silicon Nitride 40 x 17 x 28 142 15 17 x 25 x 1 4 64,000 80.0 4 Silicon Nitride 40 x 17'/2 x 28 142 15 17 x 25 x 1 3 79,000 80.0 4 Silicon Nitride 40 x 17 x 28 151 15 17 x 25 x 1 4 80,000 80.0 4 Silicon Nitride 40 x 17 x 28 153 15 17 x 25 x 1 4 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1 5 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1 6 80,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 175 20 24 x 25 x 1 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1 5 111,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1 XE 80 Single Stage, Downflow /Horizontal Left or Right Induced Draft Gas Furnace (115/1/60) Airflow Nominal Flue Uncrated Shipping In Output ICSO Size Ignition Dimensions (in.) Weight Max Filter Tons (Btuh) AFUE (in.) Device H x W x D lbs. Fuse* Sizes 2 31,000 78.0 4 Silicon Nitride 40 x 141/2 x 28 2 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 3 48,000 80.0 4 Silicon Nitride 40 x 14'/2 x 28 3 64,000 80.0 4 Silicon Nitride 40 x 17 x 28 4 64,000 80.0 4 Silicon Nitride 40 x 17'/2 x 28 4 80,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 4 80,000 80.0 4 Silicon Nitride 40 x 21 x 28 5 81,000 80.0 4 Silicon Nitride 40 x 21 x 28 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 5 113,000 80.0 4 Silicon Nitride 40 x 24'/2 x 28 TUE Single Stage, Upflow/Horizontal Left or Right Electronic Ignition Ga Airflow Nominal Flue Uncrated Shipping In Output ICS® Size Ignition Dimensions (in.) Weight Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) 2 31,000 80.0 4 Hot Surface 40 x 14'/2 x 28 119 3 47,000 80.0 4 Hot Surface 40 x 14 x 28 127 3 63,000 80.0 4 Hot Surface 40 x 17'/2 x 28 142 4 64,000 80.0 4 Hot Surface 40 x 17'/2 x 28 142 4 79,000 80.0 4 Hot Surface 40 x 17 x 28 151 4 79,000 80.0 4 Hot Surface 40 x 21 x 28 162 5 79,000 80.0 4 Hot Surface 40 x 21 x 28 162 5 96,000 80.0 4 Hot Surface 40 x 24'/2 x 28 5 111,000 80.0 4 Hot Surface 40 x 241/2 x 28 Table 36 - TDE Single Stage, Downflow/Horizontal Left Unit Model No. TDE060A936L TDE080A945L TDE100A945L TDE 100A960L TDE120A960L 0 Isolated Combustion Airflow Nominal In Output Tons (Btuh) 3 4 4 5 5 System. 48,000 64,000 80,000 81,000 96,000 ICS® Size AFUE (in.) 80.0 4 80.0 80.0 80.0 80.0 4 4 4 4 36 119 129 129 146 146 156 166 167 177 189 196 15 15 15 15 15 15 15 186 20 193 20 15 (2)14x20x1 15 (2)14x20x1 15 (2) 14 x x 1 15 (2) 14 x 20 x 1 15 (2)16x20x1 15 (2)16x20x1 15 (2)16x20x1 15 (2)16x20x1 15 (2)16x20x1 15 (2)16x20x1 15 (2)16x20x1 s Furnace (115/1/60) Max Filter Fuse' Sizes (1)16x25x1 (1)16x25 x1 (1)17x25x1 (1)17x25x1 (1)17x25x1 (1)20x25x1 (1)20x25x1 (1)24x25x1 (1)24x25x1 or Right Electronic Ignition Gas Furnace (115/1/60) Uncrated Shipping Ignition Dimensions (in.) 'Weight , Max Filter Device H x W x D (lbs.) Fuse* Sizes Hot Surface 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1 Hot Surface 40 x 17 x 28 146 15 (2)14 x 20 x 1 Hot Surface , 40 x 17 x 28 156 15 (2) 14 x 20 x 1 Hot Surface 40 x 21 x 28 167 20 (2) 16 x 20 x 1 Hot Surface 40 x 24 x 28 189 20 (2) 16 x 20 x 1 . Informations e o c confer Product Dat f lease lease fact ■ *5811 Sega le park Drive C, Seattle, WA 1st VEST "" S 200t eett czt S 204fn t S .06.4' 02000 Map/Quests:cm, Inc.; 02000 Navigation Technoloogsaj 17,,ruy• anat.:sm. •011.M 0 F111 1 lilt I_ 11 semi twit Sa (4)- ,e 245 c-F4i 'EA) PP L."1 G* I t. LS ( t06,E1 14-12, .€ ?vooiDe._ GT GE-Aer oge- - Tempe_64-77.42e. etwrlea, - Dawca -pEk, Ze>die -s T*E. t s-■"/ • 4210 f melli.a-rE 121/676 POE 1 / - roieez /4-6 R-7 /Mgr • Aa)/Pa '' roe_ 17a-/t Pr.& emorw- -0. 1)/}46 ' 303 I /I 3 PRIM PMEtiT cc t-I-tat 14P6 A T=CANAE. eGNEetass 61:›AP-4 Oe. USES A CptoWl laNIT/oN 6oviecE °pap TO Nor ee 11451 / J 6/2001 'H _ o C/141-sivit>"-irleidq446-0a:47°141-Polistiv"epfl I ow t r--4/",cze_j_fre"1-846' f."-(fr-cisrve maepreietae6 RECEIVED CITY OF TUKWILA AUG 1 5 2001 PERMIT CENTER NtOt- 138