HomeMy WebLinkAboutPermit M01-141 - BOEING #9-96M01-141 Boeing 9-96 9725 East Marginal Wy S City of Tukwila Community Development / Public Works • 0300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: MO1 -141 Type: B -MECH Category: NRES Address: 9725 EAST MARGINAL WY S Location: PHASE IV Parcel #: 000340 -0018 Contractor License No: BOEINC*294ML TENANT BOEING #9 -96 9725 EAST MARGINAL WY Si, TUKWILA WA 98188 OWNER BOEING PO BOX 3707 - M/S 1F -09, SEATTLE WA 98124 CONTACT JOHN MURDOCH PO BOX 3999 M/C 89 -15, SEATTLE WA 98124 CONTRACTOR BOEING COMPANY PO BOX 3707, M/S IF -09, SEATTLE, WA 98124 ****k **** **** ** * **** Mfr *kkk* * * * ** * *k* k*** kk• k * *kk * *kkkk *k *•k *k *k *•k k* Permit Description: EARTHQUAKE REPAIR /TENANT IMPROVEMENT /FLEX DUCT NEW GRILLS /THERMOSTATS /SMOKE DAMPERS IN CEILING GRID UMC Edition: 1997 Valuation: 95,000.00 Total Permit Fee: 115.00 * * **. **' * * * * * * * * * * * * * * * * ** ***• kk*************** * * * * * * * * ** * *:k **k **•k ** *** * * * ** ;,,, m it C er Authori ed Per Signature Date I hereby certify that I have read and examined this permit and know the same'to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction •r the performance of work. I am authorized to sign for and obtain 'thi �i l • n• per 'i , i ,/ gf ��j; r COM P7 Date: al w"'` Signature Print Name: MECHANICAL PERMIT �- 56d/ Status: ISSUED Issued: 09/04/2001 Expires: 03/03/2002 Phone: (206) 431 -3670 Phone: 253 773 -0444 • *ION Title: t4r*Coi 00 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. ! CITY OF TUKWILA Address: 9725 EAST MARGINAL WY S Permit No: M01-141 Suite' Tenant: BOEING #9!-96 Status: ISSUED Type: B-MECH , Applied: 08/22/2001 Parcel #: 000340-0018 Issued: 09/04/2001 *A**********************4.*k**4.**Ak*A*A*******A*AA*AAA*A***A********A*****k* Permit Conditions: I. Any exposed insulations backing material shall have a Flame ;Spread Rating of 25 or less,,and shall bear identi- - lication showing the fire perforMance rating thereof. 2. Electrical permlts be obtained through the Washington State Divisiope6f,T and Industries and all -electrical work will be. inspected by that,agency,(248-6630). .., .No change . s4iii ) be made to the plans unless approved. by the - i Engineer.andtheTukwi1a.Bul1d1ng Dlvisiori. , All perm4;tS, inspection °records, and approved plans shall be , 'availabOeP at tfie job'Sie to , ,the start of any con- 'struo0i)fi. These,dOcuMentsyare to be maintained and avail-, able .'until final,AnOectiOn approval is granted. 1 5. All CO'nseuction'tobe'done in conformance with approved • plannCrequt Unlform Building Code (1997 t , .. i . ., • :Edit460,,aiamended, Uniform.:,Mechanical Code (1997 ,Edition); andryashinjton StatelEner (1997 Edition). 6. Yali4ditof Permit. The issuance of a permit or approval of )10'41 :Pqci-Ocations,.tand coMpdtatiofis, shall not be con strued :tti be •a permit *or, oran'aptiroval of, any viOlation ofariy of.' provisions ofitfiebuildifigcode or of any . , , , othek:', ordinance of the .;No permit presuming to, , giO‘‘author,it to violate .or' cancel the provisions of this • code,Shal1,4be , _.." a Manu installation instructions required on site . . , • for the thlAding,i.nspectors review.. hereby certlfy that I read these conditions and will OpM0ly wlth , :them asoutttned: All provislofis:of,laW and ordinances governing this - rk will COMIAled'with, whether specified • • •• • The granting , o# s Orin l does riot - presume to ',..g fy,e1:, authority to violate or cancel prtivils'ifins :' of any ner work 'or local laws reitilating.liPtrt Per Of:is ,.„ .,- •.: ••„,,..., .,..• • .. A l - . .,, Cr ,--,.. In.'au1. 1 . - _.- Date 0 AL5EPrzot Project Name /Tenan im //I� i /a fi fe D G tr l r1 taG ►TIC/ r1 U i e.eY Value of Me ianicaquiffnl: ...-. Site Address : q w ,,,�,r Affee /V4 £ w., lily State /Z Tax Parcel Number: Property Owner'��,"r,� i` D647 4 , & P Phone: (Z 7 7,7,3 �etti S ee _ t i T mic 87' ! r a -r to '��(( `� Fax 11: (?f3) Re/go Contractor: Phone: ( ) Street Address: City State/Zip: Fax II: ( ) Cimtact Perszle ` 5 /f am // Q tm& 60 Phone: () 2- .,oge /J Sge d O V q- i 1 MA. vi _ s. itytet i_i ;:, Fax 11: (Z ) U`fr� G BUILDI r . i R O AUTHORIZED AGENT: Signat I� , v ! w, es ter% c #4r» y Date:gdatkee ZOO Print .n I • • 1 » a 6 . e Phone: (x43) Fax if: ( ) 2 - ��'- Address:p . QJ1X Q? X41 $9' f City /State/Zip '' UM, g t.* 0-4 4 7 1 ? ! I I/2/99 MCCil perodl.doc CITY OF - 'JKWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 • R STAFF SE ONLY Project Number. Permit Number. Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of wr todg (pleas i�ecifi4) G�l1�.a ,r'f1,./ otor .?t.teo teueur .Dui -7. Netu sieiu, / "T 1 / ors'' l/ 'eS i) ee ,rn r' Current copy of: Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license willbe required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PER JURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: Application taken (initials) ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify. individual equipment'and the location.of `each installation (Uniform Mechanical. Code 504 (e)) ' Details and elevations (for roof mounted equipment) and proposed screening ' Heat LossCalculations or Washington State Energy Code Form #H -7 ' ' . . I-I.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). \ Specifications must be provided to show that replacement equipment complies with the efficiency ratings `and other applicable requirements of tiietWashington State.Nonresidential Code..., .Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing`400 pounds and greate0Uniform Building Code ,1632.1),I Structural; documentation -shall be, stamped by a Washington State licensed Structural Engineer. Mechanical Permits rua!') u,J.vcpui1.doc COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. New Single Family Residence Installation of Gas Fireplace Change -out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. RESIDENTIAL: Two complete sets of attachments: required with application submittal Submittal Requirements Heat loss calculations or Form H -6. Equipment specifications. 'Narrative with specification of equipment and chimney type.. If usin existin chimney, rovide.a letter by a certified cliiriiney "swee statin that the'cliimne . is safe g g y,p y y a g v .condition. ,t\'' , • NOTE:. Water heaters: v are included in the Uniform Mechani Code - please include any heaters:or vents being installed or replaced. * A * ** *k*4* **A *kA * *Ak* t *****A* * *4 * * * *k *:k *AA * * *A*k OF;;'TUKWIL(.),.: 42A 1'RANSMlT *'* A*; 4 !******** *.*A *A* ***:k*A*AAA *•k * *A *A**A *AAA *A *• *AAA* *:k * *A•A * * *A* ANSMIT Number: Amount: 115.00 09/04/01 10:,38 ym nent Method: CHECK Notation: a01iw MURDOCH :[nit; S1( Permit; No: M01 -141. Type: H• -MECH MECHANICAL PERMIT ar ce.l `. No: 000340-0018 e : 9725 EAST MARGINAL WY S oca PHASE IV Total Feee L 115.00 ayment 11 Total ALL Purls: 115.00 ,..,.w >, Balance: .00 **** t{** xF****** A** **** 42A• k***** it***** AAdofir of**A *4A•0****it*4**A•k*i Aci ouint Code De.cr i pt'.i on Amount "/34"3° PLAN .:CHECK - NONRES 23.00 0'00/322 .100 MECHANICAL - . NONRES 92.00 Project. Type of Inspects >n"' Address: :". .:,..:. P Date cal led . 5 .-t9 2— Special instructions: 5 Date wanted: ,5 a.m. P.m. Requester: Phone: 11 • 4 • ; •••: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING. DIVISION 6300 Southcenter Blvd, #106 Tukwila, WA 98188 Approved per applicable codes. A, (206)431-3670 COMMENTS: 04 To cr›idt/ 0 Corrections required prior to approval. El $47.00 REINSPECTION FEE QUIR D. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: .4=f,; INSPECTION RECORD Retain a copy with permit .. itiSF'EGTION NO. OfTUKWILA BUILDING DIVISION SOutficeriier'Blviii #100, Tukwila WA 98188 tSPec!alinstrUctions: Typg4 Inspection: *in.Y.11 Date called: ' Date wanted: Requester: Sccri4-- Phone: APpiavedfiei-`apiilicable codes. Ei Corrections required prior to approval. loor- M-e-e-rt ioiGn , • • •:!:.•!••••*:::."- "4 . :1'%: .. -' . ..;:::' F`,:"••• 4 :::', , ,•.;" . "; - •••."- "; .„.• • ';•7• /VA MO t- 1 PEWIT NO. (206)431-3670 Date: $47,00:REINsptcpoN gE REQUIRED. Prior to inspection, fee must be paid 4C6'300Soiitl'iCentei- Suite 100. Call to schedule reinspection. Receipt No: ' Date: 7 • Project: 9 -910 Type of inspection: r ...., t--%y\ex I Address: CrD:5 I Mot . W Date called: 10—r)- -30 ( Special instructions: • I Date wanted: )0 . . Requester: s-DC 611 Phone: d-66- . 7c1•- Viog • • „ . • • ,, , ,, , (C) INSPECTION NO. INSPECTION RECORD Retain .a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. 3 (206)431-3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 11 sw-kolk Ar.tvA rs. C atr-e \\I lnspecto RCQAJer Date: 10 ...19.10...0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Landeas*Z4Savii.0444k.A. r4 § to us 0' 2 g < ( 12 11 4 3 F F2 LU uj 2 a D u), a 1- LU uj X f 0 Z W (�) (0_2 0 Proj . ■ ' n 1 -1 i Type of Inspection: ( • Address: 1 /Intl Date called: lo-te-01 •Special instructions: I Date wanted: .., Requester: , (-5COik Phone: • - . . . -•,.. ' , '• • .• • - 0= INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. PERMIT NO. (206)431-3670 COMMENTS: "f F kor A-i-O c,v,A I t o 13 NI_ 1-r, Cover F 'c re - Act vy‘ r r lec v roverk El Corrections required prior to approval. IiiSPector: ("" Date: f 0 / :.$47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 000 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: -iratiostiataRiiittatUsSi Project :,. Ty _ of Inspe) ion: dress:,' . X �j M me{ ` V Date call is S. t'7/ / Spec al. instructions ✓ Date wanted:! Q q �n� p. m. Reque tiu y Su /ft 1Va..t Date: 1( 1 ) (tJ _ g_ 54 7.00 REII NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid J ' at Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 4 INSPECTION RECORD Retain a copy with permit INSPECTIO N O. OF TUKWILA BUILDING DIVISION 63O0_So.uthce`nte�:B #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Approvedper applicable codes. Corrections required prior` to approval. COMMENTS: a IA rr CnUe INSPECTION RECORD r „. Retain a copy with permit INSPECTION NO. CITY OF,TUKWIIA BUILDING DIVISION 6300,Southcenter Blvd, #100, Tukwila, WA 98188.: prge& % dress: E Thart9 Special instructions: • Approved per applicable codes. Phonfti Ite • . ;'.- ' ' ' Corrections required prior to approval. COMMENTS:' 'iv a .• • . . ' 1 El $47.00 REINSPECTIO EE REQUIRED. Prior to inspection, fee Must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.: Receipt No: Date: PERMIT NO. (206)431•-3670 - euallettZi•iise.21. - li4zorcore.4-4tVgteaiezkid' , .. , ,-.4:Lti..tti: - 4.4' • . • , Project: ' . Txpg of Inspeftion: .,,..., Address: .-- q1 (96 ..F..... 7i4tirelirtt. • hi Date7Ile : , c - i , 7 / -Special instructions:" -/ , D anted: 1 1/75 - 70/ P• m. • Re_s Phone: 2-C10 — 7 9 3 - 3i35 . - INSPECTION RECORD otai0 a copy with permit INSPECTION NcV: T1'.OFT6141/11.A BUILDING DIVISION 300 B vd, #100, Tukwila, WA 98188 Approved per applicable codes. E] Corrections required prior to approval. Date: $47.00 REINSPECTION E REQUIRED. Prior to inspection, fee-must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: 2 , (h. j" /./1 I .-. L/P7 1. S, * -1 -1,-;1 4 t o , ,S 40,67 Receipt No: Date: 4 ' s ' .\wegi§s4tiattattAJrall8W642:At; P • ec : A et, Type of nspection: . . r e s s : 0 Date cane, 0 410P A tio . S.ecia instructions: • Date wanted. / /_ q II 3f ° ..m. . . Reque_t Phone: r oc -- pg —if-? • „ • • X " :7" ' • 0777. .-..-:;INSPECTION RECORD Retain a col* with permit ir.,11,c-riorl NO. ; • ;:':/.,';.• • • OX-TUKWIIA ,BUILDING DIVISION ODS.oUthenter Blvd, #100, Tukwila, WA 98188 isosousatiltatatkrawitoivigwae,imittittfiCtVmP!z - 17 7.717 7. • • ' , 1\ i PERMIT NO.. (206)431-3670 .'r. Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: tkvei c loc,+- ok_ -hp lAsutcv4 • GL I +0 10 C L 3 -Fa A) cwf I Id /0 Plror (c; 4 c%J L tAiD 1 +6 13 " 0° .■titY Aftr3 D a t e:9-- 13-01 $47.00 REINSPECTION FIE REQUIRED, Prior to inspection, fee must be paid 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: May 6, 2002 Mr. John Murdoch P.O. Box 3999 M/C 98 -15 Seattle, WA 98124 Dear Permit Holder: Sincerely, K. 6. ,00K) Kathryn A. Stetson Permit Technician City of Tukwila RE: Permit Application No. M01 -141 Location: Boeing 9 -96 9725 East Marginal Wy S Based on the above, you are hereby advised to: Thank you for your cooperation in this matter. Xc: Permit File No;M01 -141 ; i Bob Benedicto, Acting Building Official In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. • Call the City Of Tukwila Permit Center at (206) 431 -3670 to schedule a progress or a final inspection A progress inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one - time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicant's control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to June 9, 2002, your permit will become null and void and any further work on the project will require a new permit and associated fees. Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431.3665 t�otit enedicto -O Eerthquake Repa � ............... :: Luuuuuu.0 From: "Murdoch, John S" <john.s.murdoch @Boeing.com> To: "Miller, Geoffrey M" < geoffrey.m.miller @Boeing.com... Date: 8/30/01 3:17PM Subject: 9 -96 Earthquake Repair I had a lengthy discussion with Mr. Bob Benedicto, Senior Plans Examiner for The City of Tukwila this morning to discuss the problem of the NON RATED material in the return air plenum in the 9 -96 Earthquake repair job. We had two options: (1) Produce a Certificate of Occupancy which was issued by the King County, the jurisdiction which oversaw the construction of these buildings in the 1960's. or; (2) Find absolute proof that in the 1961 Uniform Building Code the contractor and designer of the project could allow non rated material in a return air plenum. We are unable to produce or prove either option. Thus our only recourse is to abide by current 1997 Uniform Building Code and take out ALL non plenum rated material in the plenum. I confirmed our decision with Mr. Bob Benddicto on the phone this afternoon and he informed me that he would talk to his inspectors concerning our decision. This will help free up a tent pole that has been slowing this project. John S. Murdoch The Boeing Company Code Compliance and Permits Kent Space Center /D.C. /Plant II /Spares Distribution P.O. Box 3999 M/S 89 -15 Seattle WA 98124 -2499 (253) 773 -0444 (253) 773 -2432 FAX john.s.murdoch @boeing.com Pager (206) 906 -0792 Cell (253) 951 -7668 «...OLE_Obj...» CC: "Morvice, Mark D" <mark.d.morvice @Boeing.com >, "Cr... • .m3.L:..531�. -'a .�.:L�'13h• yw.. tam: km... v..c.L.._.....��41�{L.ia.S•.li.i BUILDING DIVISION REVEIW Date: Aug. 28, 2001 Project Name: Boeing #9 -96 Phase 3 and 4 Mechanical Permit Applications Application #: M01 -140 and M01 -141 Plan Review: Ken Nelsen, Plans Examiner A general Building Division plan review has been completed for the subject projects. However before the permits can be issued, the discussion with Bob Benedicto, Senior Plans Examiner regarding the existing duct materials acceptability to remain within the plenum ceiling must be resolved. Please provide the appropriate flame spread and smoke development documentation on the exiting flex duct or revise the design to include new plenum duct materials. No further comments at this time. 61.i) kit \P‘ Tukwila Building Division 6300 SouthCenter Blvd. Tukwila, WA 98188 206 -431 -3670 ACTIVITY NUMBER: M01 - 141 DATE: 8 -22 -01 PROJECT NAME: 9 -96 EARTHQUAKE RECV'Y IV SITE ADDRESS: 9725 EAST MARGINAL WAY SOUTH XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Bu i Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES /THURS ROUTING: Please Route \PRROUTE.DOC 5/99 Incomplete n Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved n Approved with Conditions REVIEWER'S INITIALS: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP C6 � Fire Prevention iv] Structural n Planning Division Permit Coordinator DUE DATE: 8-23-01 Not Applicable No further Review Required DUE DATE 09 -20 -01 DATE: Not Approved (attach comments) DATE: DUE DATE Not Approved (attach comments) DATE: �oD o • 7-127 FROM SEATTLE - TACOMA AIRPORT FROM DOWNTOWN SEATTLE EAST MARGINAL WAY CORPORATE PARK DEVELOPMENTAL CENTER nn t►EI BOEING ACCESS RD Ni Dar 157 Exr 157 599 TUKWILA LI UILDI FROM KENT & AUBURN 117 17 111 NO SCALE 900 REVISION -96 TE PROJECT SITE 9 -96 BUILDING LOCATION ANT AREA MAP SYM PROJECT SITE REVISION A BUILDING 9 -98 STRUCTURAL UPGRADE VICINITY MAP OXBOW LOT B BUILDING 9 -96 T.I. #1 4715225 -00 C BUILDING 9 -96 T.I. #2 J #715225 -00 703445 -03 BY APPROVED DLR GROUP GM DLR GROUP DLR GROUP 04 24 01 06.29.01 07.13.0 BUILDING ADDRESS: 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON APPROVED DATE NO SCALE en dicta - _.. Bob � one icfo - 9 -96 Earthquake Repair "MOrvice, Mark D" <mark.d.morvice @Boemg.com >, "Cr._ OEIN o' PROVEMENT #4 MECH BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1 VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK 2 NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WLIN OTHER CRAFTS. 4. RETURN THIS SAME SET TO GARY TALLER AT BLDG. 9 -51 COL N /1, AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT CHECKLIST CHECK BOX THESE DRAWINGS CONFORM TO THE U.B.C. - U.F.C., U.P.C., AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10 -A. BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. ® ' NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. TENANT IMPROVEMENT (STRUCTURAL): ❑ 5 SETS OF ARCHITECTURAL DRAWINGS ❑ 5 SETS OF STRUCTURAL DRAWINGS ❑ 5 SETS OF STANDARD DETAILS ❑ 5 SETS OF ENGINEERING CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS 0 5 SETS OF CONSTRUCTION SPECIFICATIONS ® 2. TENANT IMPROVEMENT (NON- STRUCTURAL): El 4 SETS OF ARCHITECTURAL DRAWINGS ❑ 4 SETS OF STANDARD DETAILS ❑ 4 SETS OF ENERGY CALCULATIONS ❑ 4 SETS OF CONSTRUCTION SPECIFICATIONS ® MECHANICAL, 4 COMPLETE SETS ® FIRE PROTECTION /SPRINKLERS, 8 COMPLETE SETS ® BRIEF PROJECT NARRATIVE: INTERIOR DEMOLITION OF 66,300 SF OF INTERIOR SPACE AND CONSTRUCTION OF GROUP B OCCUPANCY OFFICE. ACCEPTABILITY Tr11S DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CHECKED ENGINEER CHECKED APPROVED Ic DATE CODE SUMMARY LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: TOTAL BUILDING FOOTPRINT TOTAL BUILDING GROSS FIRST FLOOR SECOND FLOOR PENTHOUSE BUILDING HEIGHT STORIES HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE 3 OCCUPANT LOAD: (BASED ON USE) From: Murdoch, John S" cjohn.s:murdoch @Boeing.conv To 'Miller, Geoffrey M" <geoffrey.m.miller @Boeing.com... Date: 8/30/01 3:17PM Subject: ': 9 -96 Earthquake Repair I had a lengthy discussion with Mr Bob Benedlcto, Senior Plans Examiner for The City of Tukwila this eeoming to discuss the problem of the NON RATED material in The return air plenum in the 9 -96 Earthquake repair job We had two options: (1) Produce a Certificate of Occupancy which was issued by the King County, the jurisdiction which oversaw the construction of these buildings in the 1960'V or (2). Find absolute proof that in the 1961 Uniform Building Code the contractor and designer of the project could allow non rated material in a return air plenum. We are unable to produce or prove either option. Thus our only recourse is to abide by current 1997 Uniform Building Code and take out ALL non plenum rated material in.the plenum_ I confirmed our decision with Mr Bob Benddicto on the phone this afternoon and he informed me that he would talk to his Inspectors concerning our decision. This will help free up a tent pole that has been slowing this ...project. "John S. Murdoch. The Boeing Company Code Compliance and Permits Kent Space Center/D.C./Plant II /Spares Distribution P.O. Box 3999' - "'M /S 89 -15. Seattle WA 981242499 (253) 773-0444 (253) 773 -2432 FAX johh.s.murdodh ©boeing.corn Pager (206) 906 -0792 Cell (253) 951 -7668 «...OLE_Obj:.». CITY OF TUKWILA �j�v1 U.B.C., U.F.C., U.P.C., AND THE WAC 51 -20 AS -1 11 / A OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. GROUP B TYPE II, NON - RATED F,,,_ COPY I understand that the Flan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans ackncwiedgal 101,717 S.F. 218,847 S.F. 101,717 S.F. 101,717 S.F. 15,413 S.F. 2 44 FT. BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT 1st FLOOR 930 2nd FLOOR 972 RATED CORRIDORS REQUIRED FROM 2nd FLOOR LIMITED ACCESS SECURE OFFICE AREAS DUE TO OCCUPANCY LOAD EXITING THROUGH INTERVENING ROOMS PER UBC 1004.2.2., EXCEPTIONS 2 & 4. STAIRS INCLUDED IN AND OPEN TO CORRIDORS WHERE INDICATED. MAX DISTANCE TO EXIT OR EXIT DISCHARGE ALLOWED: 350 FT IF EXIT LENGTH IN EXCESS OF 250 FT IS IN CORRIDOR (UBC 1004.2.5.2.2 AND 1004.2.5.2.3 FOR SPRINKLERED BUILDINGS) FIRE EXTINGUISHERS: TYPE: 3A -40 B:C, 6 POUND CAPACITY, SPECIFIED FOR USE ON THIS PROJECT. MAXIMUM TRAVEL DISTANCE TO REACH EXTINGUISHER = 75 FEET ORDINARY (LIGHT) HAZARD CLASSIFICATION MAXIMUM FLOOR AREA PER EXTINGUISHER = ,ALLOWABLE AREA 9,060 SF ACTUAL AREA: 6,057 SF SUBTITLE MAX DISTANCE TO EXIT DISCHARGE POINT: 336' (<350') ALL NEW OPEN OFFICE AREAS, ON EITHER FLOOR, ARE WITHIN 250 ISCHARGE POINT. TrAE BUILDING 9-96 TENANT IMPROVEMENT #4:..' BUILDING 9-96 By �J Date Permit No NO CHAJ'a3os 751E SCOPE OF k APPROVAL OF TUK?'71 NaTE: REVISIONS WILL AND MAY INCLUDE ACt4'a0: 4I. JOB NO. CURRENT REVISION J #7 1 5225, -00 IONS can 7A E"TO SEPARATE PERMIT REOU?RED FOR: D �� E IRICAL LUMBING DI GAS PIPING CITY OF TUKWILA BUILDING DIVISION SYMBOL SHEET T1 ,47150 7 5 -00 C.1 N!� DATE E 08.10.01 COMP NO. DRAWING INDEX - v v v v INCLUDED IN SET DRAWING N0. SHEET N0. SHEET TITLE RE DATE MECHANICAL REMOVAL * 9-96-1M11OR 1M11OR PLUMBING REMOVAL PLAN A 08.10.01 * 9- 96- 1M111R 1M111R PLUMBING REMOVAL PLAN A 08.10.01 * 9-96-1M112R 1M112R PLUMBING REMOVAL PLAN A 08.10.01 * 9-96-1M113R 1 M 113R PLUMBING REMOVAL PLAN A 08.10.01 *' 9- 96- 1M114R 1M114R PLUMBING REMOVAL PLAN E 08.10.01 * 9- 96- 1M115R 1M115R PLUMBING REMOVAL PLAN H 08.10.01 * 9- 96- 2M11OR 2M11OR PLUMBING REMOVAL PLAN A 08.10.01 * 9-96-2M111R 2M111R PLUMBING REMOVAL PLAN A 08.10.01 9-96-2M1 2R 2M112R PLUMBING REMOVAL PLAN A 08.10.01 9- 96- 2M113R 2M113R PLUMBING REMOVAL PLAN A 08.10.01 9- 96- 2M114R 2M114R PLUMBING REMOVAL PLAN C 08.10.01 * 9- 96- 2M115R 2M115R PLUMBING REMOVAL PLAN C 08.10.01 9- 96 -1A13R Al 3R REMOVAL PARTIAL FLOOR PLAN 0 08.10.01 9- 96 -1A14R 1A14R ELECTRICAL REMOVAL K 08.10.01 9- 96 -1E10R ' 1E1OR PARTIAL LIGHTING REMOVAL PLAN p 08.10.01 9 -96 -1 E11 R 1 E11 R PARTIAL LIGHTING REMOVAL PLAN G 08.10.01 9-96-1E12R 1E12R PARTIAL LIGHTING REMOVAL PLAN G 08.10.01 9 -96 1 E13R 1E13R PARTIAL LIGHTING REMOVAL PLAN I 08 10.01 9-96-1E14R 1E14R PARTIAL LIGHTING REMOVAL PLAN I 08.10.01 9-96-1E15R 1E15R PARTIAL LIGHTING REMOVAL PLAN H 08.10.01 9- 96 -2E1OR 2E1OR PARTIAL LIGHTING REMOVAL PLAN D 08.10.01 9- 96 -2E11 R 2E11 R PARTIAL LIGHTING REMOVAL PLAN E 08.10.01 9- 96 -2E12R 2E12R PARTIAL LIGHTING REMOVAL PLAN F 08.10.01 9- 96 -2E13R 2E13R PARTIAL LIGHTING REMOVAL PLAN I 08.10.01 9- 96 -2E14R 2E14R PARTIAL LIGHTING REMOVAL PLAN I 08.10.01 9- 96 -1E6OR 1E6OR PARTIAL 208Y/120V POWER REMOVAL PLAN F 08.10.01 9- 96 -1E61R 1E61R PARTIAL 208Y/120V POWER REMOVAL PLAN F 08.10.01 9- 96 -1E62R 1E62R PARTIAL 208Y /120V POWER REMOVAL PLAN M 08:10.01 9- 96 -1E63R 1E63R PARTIAL 208Y/120V POWER REMOVAL PLAN M 08.10.01 9- 96 -2E60R 2E60R PARTIAL 208Y/120V POWER REMOVAL PLAN L 08.10.01 9-96-2E61R 2E61R PARTIAL 208Y/120V POWER REMOVAL PLAN K 08.10.01 9- 96 -2E62R 2E62R PARTIAL 208Y/120V POWER REMOVAL PLAN J 08.10.01 * 9- 96- 2A285R 2A285R REMOVAL REFLECTED CEILING PLAN G 08.10.01 * 9- 96 -IM11 1M11 ARCHITECTURAL F 08.10.01 9- 96 -1A10 1A10 PARTIAL FLOOR PLAN G 08.10.01 * 9- 96 -1A11 1A11 PARTIAL FLOOR PLAN E 08.10.01 * 9- 96 -1Al2 1Al2 PARTIAL FLOOR PLAN D 08.10.01 9- 96 -1A13 1A13 PARTIAL FLOOR PLAN L 08.10.01 * 9- 96 -1A14 1A14 PARTIAL FLOOR PLAN J 08.10.01 * 9- 96 -1A15 1A15 PARTIAL FLOOR PLAN H 08.10.01 * 9- 96 -2A10 2A10 PARTIAL FLOOR PLAN F 08.10.01 A 9- 96 -2A11 2A11 PARTIAL FLOOR PLAN 0 08.10.01 * 9- 96 -2Al2 2Al2 PARTIAL FLOOR PLAN D 08.10.01 9- 96 -2A13 2A13 PARTIAL FLOOR PLAN N 08.10.01 9- 96 -2A14 2A14 PARTIAL FLOOR PLAN K 08.10.01 9- 96 -2A15 2A15 PARTIAL FLOOR PLAN K 08.10.01 DRAWING INDEX INCLUDED IN SET DRAWING N0. SHEET N0. SHEET TITLE REV NO DATE GENERAL * 9- 96 -.AO Ti TITLE SHEET E 08.10.01 * 9- 96 -G1.1 G1.1 SHEET INDEX E 08.10.01 * 9- 96 -G1.2 G1.2 SHEET INDEX E 08.10.01 * 9 -96 -G2 G2 ABBREVIATIONS AND SYMBOLS A 08.10.01 9-96-1A284 1A284 REFLECTED CEILING PLAN G 08.10.01 9 -96 -1.x01 1A01 1ST FLOOR EXITING PLAN L 08.10.01 9- 96 -2A01 2A01 2ND FLOOR EXITING PLAN B 08.10.01 9- 96 -2A281 2A281 REFLECTED CEILING PLAN C 08.10.01 9- 96 -2A282 2A282 ARCHITECTURAL REMOVAL C 08. 10.01 9-96-1A OR Al OR REMOVAL PARTIAL FLOOR PLAN H 08.10.01 9- 96 -1A11R 1A11R REMOVAL PARTIAL FLOOR PLAN G 08.10.01 9- 96 -1Al2R 1Al2R REMOVAL PARTIAL FLOOR PLAN G 08.10.01 9- 96 -1A13R Al 3R REMOVAL PARTIAL FLOOR PLAN 0 08.10.01 9- 96 -1A14R 1A14R REMOVAL PARTIAL FLOOR PLAN K 08.10.01 9- 96 -1A15R 1A15R REMOVAL PARTIAL FLOOR PLAN I 08.10.01 9- 96 -2A1GR 2A10R REMOVAL PARTIAL FLOOR PLAN G 08.10.01 9- 96 -2A11R 2A11R REMOVAL PARTIAL FLOOR PLAN F 08.10.01 9- 96 -2Al2R 2Al2R REMOVAL PARTIAL FLOOR PLAN F 08.10.01 9- 96 -2A13R 2A13R REMOVAL PARTIAL FLOOR PLAN J 08.10.01 9- 96- 2A145 2A14R REMOVAL PARTIAL FLOOR PLAN M 08.10.01 9- 96 -2A15R 2A15R REMOVAL PARTIAL FLOOR PLAN H 08.10.01 9- 96- 1A280R 1A280R REMOVAL REFLECTED CEILING PLAN D 08.10.01 9- 96- 1A281R 1A281R REMOVAL REFLECTED CEILING PLAN G 08.10.01 9- 96- 1A282R 1A282R REMOVAL REFLECTED CEILING PLAN F 08.10.01 9- 96- 1A283R 1A283R REMOVAL REFLECTED CEILING PLAN G 08.10.01 9- 96- 1A284R 1A284R REMOVAL REFLECTED CEILING PLAN F 08.10.01 9- 96- 1A285R 1A285R REMOVAL REFLECTED CEILING PLAN G 08.10.01 9- 96- 2A280R 2A280R REMOVAL REFLECTED CEILING PLAN F 08.10.01 9- 96 -2A281 R 2A281R REMOVAL REFLECTED CEILING PLAN E 08.10.01 9- 96- 2A282R 2A282R REMOVAL REFLECTED CEILING PLAN E 08.10.01 9- 96- 2A283R 2A283R REMOVAL REFLECTED CEILING PLAN F 08.10.01 9- 96- 2A284R 2A284R REMOVAL REFLECTED CEILING PLAN H 08.10.01 * 9- 96- 2A285R 2A285R REMOVAL REFLECTED CEILING PLAN G 08.10.01 * 9- 96 -IM11 1M11 PAR11AL HVAC PLAN F 08.10.01 9- 96 -1M12 1M12 MECHANICAL REMOVAL D 08.10.01 * 9- 96 -1M10R 1M10R HVAC REMOVAL PLAN C 08.10.01 * 9- 96 -1M11R 1M11R HVAC REMOVAL PLAN H 08.10.01 9- 96 -1M12R 1M12R HVAC REMOVAL PAN E 08.10.01 * 9- 96 -lM13R M1 3R HVAC REMOVAL PLAN I 08.10.01 * 9- 96 -1M15R 1M15R HVAC REMOVAL PLAN H 08.10.01 * 9- 96 -2M10R 2M1OR HVAC REMOVAL PLAN D 08.10.01 A 9- 96 -2M11R 2M11R HVAC REMOVAL PLAN D 08.10.01 * 9- 96 -2M12R 2M 2R HVAC REMOVAL PLAN D 08.10.01 9- 96 -2M13R 2M13R HVAC REMOVAL PLAN D 08.10.01 9- 96 -2M14R 2M14R HVAC REMOVAL PLAN E 08.10.01 DRAWING INDEX INCLUDED IN SET DRAWING N0. SHEET NO. SHEET TI LE RE/ N0. DATE ARCHITECTURAL 9- 96 -1A280 1A280 REFLECTED CEILING PLAN', B 08.10.01 9- 96 -1A281 1A281 REFLECTED CEILING PLAN : E 0810.01 9- 96 -1A282 1A282 REFLECTED CEILING PLAN D 08.10.01 9- 96 -1A283 1A283 REFLECTED CEILING PLAN F 08.10.01 9-96-1A284 1A284 REFLECTED CEILING PLAN G 08.10.01 9- 96 -1A285 1A285 REFLECTED CEILING PLAN F 08.10.01 9- .96 -2A280 2A280 REFLECTED CEILING PLAN D 08.10.01 9- 96 -2A281 2A281 REFLECTED CEILING PLAN C 08.10.01 9- 96 -2A282 2A282 REFLECTED CEILING PLAN C 08. 10.01 9- 96 -2A283 2A283 REFLECTED CEILING PLAN E 08.10.01 9- 96 -2A284 2A284 REFLECTED CEILING PLAN G 08.10.01 9- 96 -2A285 2A285 REFLECTED CEILING PLAN G 08.10.01 9- 96 -1A452 1A452 PLAN DETAILS g 08.10.01 9- 96 -1A453 1A453 PLAN DETAILS - TOILET ROOMS A 08.10.01 9- 96 -1A454 1A454 PLAN AND ELEVATION DETAILS - TOILET ROOMS - 08.10.01 9- 96 -A350 A350 DOOR SCHEDULE D 08.10.01 9-96-A351 A351 DOOR SCHEDULE p 08,10.01 9- 96 -A352 A352 HARDWARE SCHEDULE AND DOOR DETAILS D 08.10.01 9-96-A353 A353 ROOM FINISH SCHEDULE A 08.10.01 9-96-A354 A354 OUTLINE SPECIFICATION INFORMATION - 08.10.01 9- 96 -A370 A370 INTERIOR ELEVATIONS C 08.10.01 9- 96 -A371 A371 INTERIOR ELEVATIONS - STOREFRONT A 08.10.01. 9- 96 -A500 A500 SECTIONS AND DETAILS N 08.10.01 9- 96 -A501 A501 SECTIONS AND DETAILS G 08.10.01 9- 96 -A502 A502 SECTIONS AND DETAILS C 08.10.01 9- 96 -A503 A503 SECTIONS AND DETAILS A 08.10.01 9- 96 -A504 A504 STAIR SECTIONS AND DETAILS A 08.10.01 9-96-A559 A559 BRACING SECTIONS AND DETAILS g 08.10.01 9- 96 -A561 I A561 DETAILS AND SECTIONS A 08.10.01 MECHANICAL * 9- 96 -1M10 1M10 PARTIAL HVAC! PLAN g 08.10.01 * 9- 96 -IM11 1M11 PAR11AL HVAC PLAN F 08.10.01 9- 96 -1M12 1M12 PARTIAL HVAC PLAN D 08.10.01 9- 96 -1M13 1M13 PARTIAL HVAC PLAN I 08.10.01 9- 96 -1M14 1M14 PARTIAL HVAC PLAN H 08.10.01 9- 96 -1M15 1M15 PARTIAL HVAC PLAN H 08.10.01 * 9- 96 -2M10 2M10 PARTIAL HVAC PLAN C 08.10.01 * 9- 96 -2M11 2M11 PARTIAL HVAC PLAN C 08.10.01 * 9- 96 -2M12 2M12 PARTIAL HVAC PLAN C 08.10.01 9- 96 -2M13 2M13 PAR11AL HVAC PLAN C 08.10.01 9- 96 -2M14 2M14 PAR11AL HVAC PLAN D 08.10.01 9- 96 -2M15 2M15 PAR11AL HVAC PLAN D 08.10 90 SYM A REVISION BUILDING 9 -98 STRUCTURAL UPGRADE BUILDING 9 -96 T.I. # BUILDING 9 -96 T.I. #2 703445 -03 J #715225 -00 J #715225 -00 BY DLR GROUP DLR GROUP DLR GROUP APPROVED GM G.M. G.M. DATE 04 24 01 06.29.01 07.27.01 SYM REVISION APPROVED DATE iSLAritistrAw. ECHANICA ACCEPTABILITY THS, DESIGN'. AND /OR SPECIRCATION IS. APPROVED APPROVED BY DEPT. DATE DRAWN CHECKED EN R CHECKED DATE SUBTITLE SHEET INDEX TIT LE BUILDING 9 -96 TENANT IMPROVEMENT #4 R1I11 flIN( a_QR CURRENT REVISION J #715225 - 00 SHE JOB N0. SYMBOL G1.1 DATE 08.10.01 COMP Na , DRIWIGINDX v w INCLUDED IN SET DRAWING N0. SHEET N0. SHEET TITLE REV N0. DATE MECHANICAL * 9 -96 -114110 1 PARTIAL PLUMBING PLAN A 08.10.01 A 9 -96 -114111 1M111 PARTIAL PLUMBING PLAN A 08.10.01 A 9- 96 -1M112 1M112 PARTIAL PLUMBING PLAN B 08.10.01 A 9 -96 -1 M114 1M114 PARTIAL PLUMBING PLAN E 08.10.01 * 9 96 114115 1M115 PARTIAL PLUMBING PLAN p 08.10.01 A 9- 96 -2M110 2M110 PARTIAL PLUMBING PLAN A 08.10.01 A 9- 96 -2M111 2M111 PARTIAL PLUMBING PLAN A 08.10.01 9 96 214112 214112 PARTIAL PLUMBING PLAN A 08.10.01 * 9 96 211114 214114 PARTIAL PLUMBING PLAN C 08.10.01 A 9- 96 -2M115 2M115 PARTIAL PLUMBING PLAN g 08.10.01 9 96- 1141260 1M260 PARTIAL FIRE PROTECTION PLAN g 08.10.01 9 96 114261 1M261 PARTIAL FIRE PROTECTION PLAN D 08.10.01 9 96 1 14262 1M262 PARTIAL FIRE PROTECTION PLAN C 08.10.01 9 96 114263 1M263 PARTIAL FIRE PROTECTION PLAN E 08.10.01 9 96 114264 1M264 PARTIAL FIRE PROTECTION PLAN G 08.10.01 9 96 114265 114265 PARTIAL FIRE PROTECTION PLAN E 08.10.01 9 - 96 - 214260 214260 PARTIAL FIRE PROTECTION PLAN D 08 . 10 . 01 9 96 214261 214261 PARTIAL FIRE PROTECTION PLAN C 08.10.01 9 96- 2:4262 214262 PARTIAL FIRE PROTECTION PLAN C 08.10.01 9 96 214263 214263 PARTIAL FIRE PROTECTION PLAN D 08.10.01 9 96 214264 21426; PARTIAL FIRE PROTECTION PLAN F 08.10.01 9 96 214265 214265 PARTIAL FIRE PROTECTION PLAN F 08.10.01 . * 9- 96 -M523 M523 PLUMBING SCHEDULE A 08.10.01 ELECTRICAL 9 96 1 E1 D 1 E10 PARTIAL LIGHTING PLAN E 08.10.01 9 96 1 E1 1 1 E1 1 PARTIAL LIGHTING PLAN I 08.10.01 9 96 1 E12 1 E12 PARTIAL LIGHTING PLAN G 08.10.01 9 96 1 E13 1 E13 PARTIAL LIGHTING PLAN I 08.10.01 9 96 1 E14 1 E14 PARTIAL LIGHTING PLAN J 08.10.01 9 96 1E15 E15 PARTIAL LIGHTING PLAN H 08.10.01 9 96 2E10 2E10 PARTIAL LIGHTING PLAN E 08.10.01 9 96 2E11 2E11 PARTIAL LIGHTING PLAN 0 08.10.01 9 96 2EI2 2E12 PARTIAL LIGHTING PLAN E 08.10.01 9- 96 -2E13 2E13 PARTIAL LIGHTING PLAN H 08.10.01 9- 96 -2E14 2E14 PARTIAL LIGHTING PLAN J 08.10.01 9- 96 -2E15 2E15 PARTIAL LIGHTING PLAN F 08.10.01 9- 96 -1E60 1E60 PARTIAL 208Y/120V POWER PLAN E 08.10.01 9- 96 -1E61 1E61 PARTIAL 208Y/120V POWER PLAN F 08.10.01 9- 96 -1E62 1E62 PARTIAL 208Y/120V POWER PLAN N 08.10.01 9- 96 -1E63 1E63 PARTIAL 208Y/120V POWER PLAN P 08.10.01 9- 96 -1E64 1E64 PARTIAL 208Y/120V POWER PLAN F 08.10.01 9-96-1E65 1E65 PARTIAL 208Y/120V POWER PLAN p 08.10.01 9- 96 -2E60 2E60 PARTIAL 208Y/ 120v POWER PLAN E 08.10.01 9- 96 -2E61 2E61 PARTIAL 208Y/120V POWER PLAN F 08.10.01 9- 96 -2E62 2E62 PARTIAL 208Y/120V POWER PLAN J 08.10.01 9- 96 -2E63 2E63 PARTIAL 208Y/120V POWER PLAN N 08.10.01 9- 96 -2E64 2E64 PARTIAL 208Y/120V POWER PLAN K 08.10.01 Z 9- 96 -2E65 2E65 PARTIAL 208Y/120V POWER PLAN U 08.10.01 - N/ v v v v v v v v v v v V V v v v v v v v- DRAWING INDEX INCLUDED IN SET DRAWING NO SHEET N0. SHEET TITLE REV N0. DATE ELECTRICAL 9-96-1E360 1E360 PARTIAL TELEPHONE /DATA PLAN E 08.10.01 9- 96 -1E361 1E361 PARTIAL TELEPHONE /DATA PLAN F 08.10.01 9- 96 -1E362 1E362 PARTIAL TELEPHONE /DATA PLAN N 08.10.01 9 96 -1E363 1E363 PARTIAL TELEPHONE /DATA PLAN I 08.10.01 9- 96 -1E364 1E364 PARTIAL TELEPHONE /DATA PLAN H 08.10.01 9- 96 -1E365 1E365 PARTIAL TELEPHONE /DATA PLAN H 08.10.01 9- 96 -2E360 2E360 PARTIAL TELEPHONE /DATA PLAN E 08.10.01 9- 96 -2E361 2E361 PARTIAL TELEPHONE /DATA PLAN D 08.10.01 9- 96 -2E362 2E362 PARTIAL TELEPHONE /DATA PLAN J 08.10.01 9- 96 -2E363 2E363 PARTIAL TELEPHONE /DATA PLAN G 08.10.01 9- 96 -2E364 2E364 PARTIAL TELEPHONE/DATA PLAN K 08.10.01 9- 96 -2E365 2E365 PARTIAL TELEPHONE /DATA PLAN U 08.10.01 9-96-E4 E4 r SINGLE LINE DIAGRAM C 08.10.01 9- 96 -E500 E500 LIGHTING FIXTURE SCHEDULE E 08.10.01 A REVISION BUILDING 9 -98 STRUCTURAL UPGRADE BUILDING 9 -96 T.I. #1 BUILDING 9 -96 T.I. #2 703445 -03 J #715225 - 00 J #715225 -00 BY DLR GROUP DLR GROUP DLR GROUP APPROVED GM G.M. G.M. DATE 04 24 01 06.29.01 07.27.01 SYM REVISION APPROVED DATE ? ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED B DEPT DATE DRAWN CHECKED ENGINEER CHECKED NICAL PERMI SET DATE SUBTBLE" M01-141 SHEET INDEX TITLE BUILDING 9-96 TENANT IMPROVEMENT #4 RAIL min A -AA CURRENT REVISION J #715225 -00 SHEET JOB ND. coo* 1.0 CITY t oo SYMBOL G1.2 DATE COMP NO: 08.10.01 SY A ABBREVIATIONS A/C Air Condilioning(er) A AMP Ampere Compressed Air AAP Area Alarm Panel AAV Automatic Air Vent AB .Anchor Bolt ABS Acry lonilr.le Butadiene Styrene AC Acoustical Ceiling AC Attempting Current ACC Air Cooled Condenser ACLU Air Cooled Condensing Unit ACP Acoust.cal Ceiling Panel ACST Acoustid ACT Acoustic Ceiling The (Panels) AD Access Door AD Area Drain ADDN Additiar or Additional ADJ Adjustotde ADJT Adjacent ADMIN Administration AF Air Filter AFF Above Firish Floor AHU Air Handing Unit AI Area Intent ALT Alternate ALUM Aluminum AMB Ambient ANCH Anchor AP Access Panel APPROX Approximate AR Acid Resisting ARCH Architectural ASB Asbestos ASPH Asphalt AUTO Automatic AV Acid Vent AV Air Vent AV Average AW Acid Waste AWP Acoustical Wall Panel AWPA American Wood Preservers Association B to BBO BC BCMU BD BDD BET BFR BE BFV BHP BIT BL BLDG BLK BLKG BLKHD BM BM B.O. BOF BOTT BRDG BRG BRKi BSMT BT BTU BTUH BUR BV CA CAB CANT CAP CAS CBD CD COX CCTV CE CEM CENT CER CERTILE CF CFH CFM CG CH CI CI CIP CIP CIRC CJ CJA CL CL CLG CLOS CLR CMP CMU CO CO COL COM COMB COMM COMP COMP COMPR CONC CONE CONFIG CONN CONN CONS' CONT CONTA CONE CORR CP CPT CR CR CS CS CS CSK COP CSTJ CSWK CT CT CTR CU BUILDING 9 - 96 T.I. #4 Back to Bark Boiler Boiler Blow off Balancing Cock Burnished CMU Board Bock Draft Damper Between Beiow Floor Boiler Feed Butterfly Valve Break Horse Power Bitumen Bolding Line Building Block Blocking Bulkhead Beam Bench Mork Bottom of Bottom of Footing Bottom Bridging Bearing Bracket Basement Bath AND British Thermal Unit BTU Per Hour Built Up Roofing Ball Valve Condenser Water Combustion Air Cabinet Cantilever Capacity Casing Chalkboard Condensate Drain Grade C —D Exterior Plywood Closed Circuit Television Cover Elevation Cement Centrifugal Ceramic Ceramic Tile Cubic Feet Cubic Feet Per Hour Cubic Feet Per Minute Corner Guard Channel Cast Iron Curb Inlet Cost In Place Cast Iron Pipe Circulating Control Joint Control Joint Above Centerline Circuit Line Ceiling Closet Clear Corrugated Metal Pipe Concrete Masonry Unit Cleanout Conduit Only Column Common Combination Communications Composite Compressor Unit Compressible Concrete Conference Configuration Connect(ion) Connection Construction Continuous Contractor or Contract Convector Corridor Condenser Pump Carpet Condenser Water Return Corrosion Resistant Countersink Combination Sewer Condenser Water Supply Countersunk Combination Standpipe Construction Joint Casework Cooling Tower Ceramic file Center Copper REVISION J #715225 - 00 CU CU CU CUM CW CV CWR CWS CY CYL B BL DC DCJ DO DEG DEPR DEPT GET DF DER DFS BEV DG DH DI DI DIA DIAL DIFF DIM DISCH DISTR DL DM DMPR DN DN DO OR DPFG DPS DR DR DS DS DSP DTL DTR DW DWG DWL DWR DXS EA EA EAT EH EDH EE EER EEW SEWS EF EF EFF EH EIFS EJ EL OAS ELEC ELEV EM ENCL EGAD EP ERF GO EQUIP ER ES ES ESP EST ET EW EWC EWA EViff EXC EXH EXIST EXP EXP EXPL EXT A AB FB FBOIC FC FCMU FCC ECU FD FD FDC FDN FOR FE EEC FF FH FH FHC FIG AN FIX FL FLASH FLEX FLOOR FLG FM FM FME BY DLR GROUP Condensing Unit Cubic Combination Unit Cabinet Unit Heater Cold Water Condom Vendor Chilled Water Return Chilled Water Supply Cubic Yard Cylinder Drain Depth Data Dryer (Residential Appliance) Dry Bulb Deformed Bar Anchor Double Dust Collector Dummy Control Joint Penny (as nail 10d) Direct Digital Degree Depress(ion)(ed) Department Detention Drinking Fountain Diesel Fuel Return Diesel Fuel Supply Diesel Fuel Vent Door Griile Duct Heater Deionized Water Ductile Iron Diameter Diagonal Diffuser Dimension Discharge Distribution Dead Load Damper Motor Damper Down Downspout Nozzle Ditto Compared o Diff. Pressure Switch Door Drain Downspout Dist ned water Dry Standpipe Detail Duct Thru Roof Dishwasher (Residential Appliance) Drawing Dowel Drawer Double Extra Strong East Existing Each Exhaust Air Entering Air Temperature Expansion Bolt Electric Duct Heater Each End Energy Efficiency Ratio Emergency Eyewash Emergency Eyewash /Shower Each Face Exhaust Fan Efficiency Electrical Heater Exterior Insulation And Finish System Expansion Joint Elevation Elastomeric Electric(al) Elevator Emergency EnclosureENTR Entrance End of Main Drip Eectro— Pneumatic Epoxy Resin Flooring Equal Equipment Exhaust Register Emergency Shower Extra Strong External Static Pressure Estimate Expansion Tank Each Way Electric Water Cooler Electric Water Heater Entering Water Temperature Excavate Exhaust Existing Expansion Exposed Explosion Exterior Fahrenheit Fire tine Furnace Fire Alarm Fresh Air Fabricated Face Back, Furnished By Owner, Installed Foot Candle Fluted CMU Floor Clean Out Fan Coif U. Fire Floor Drain Damper Fire Deportment Connection Foundation Feeder Fire Extinguisher Fire Extinguisher Cabinet Finish Floor Filter Housing Fire Hydrant Fire Hose Cabinet Figure Enish Fixture Floor Flashing Flexible Fluorescent Flooring Factory Mutual Fire Main Flow Measuring Equipment APPROVED C.M. DATE 08.1 FO FO FOC FOF FOF FOM FOR FOS FOS FOV FOW FP FPD FPM FR FR FS FS FSD FSS FT FT Fi FTG FUT FVC FWC GA GAL GALA GB GCO GCMU GD GEN GEN GFA GFl GFRC GHR GHS GI GL GL GMU GND COW GPH GPM GR GR GR GRC GRC GRGP GRS GS GV GW GWB GYP H TE HB HC HC HD HD HOBO HDR HDWD HDWR HEV HID HM HOA HORS HP HP HP HPR HPS HPSS HR HR HS HSTR HTG HTR HUM HV HVAC HW HWC HWR HWS HX HZ 18 ES IJ DS MC IN NC By Contractor lNSUL SYM JAN JB JCT JT KCJ KCP KD KH KHE KHS KIT KO KS KV KVA KVAR KW KWH Face of Finish Opening Face of Concrete Face of Finish Fuel Oil Fill Face of Masonry Fuel Oil Return Face of Stud Fuel Oil Supply Fuel Oil Vent Face of Wail Fireproofing Ere Pump Discharge Feet Per Minute Fire Resistive Frame Floor Sink Flow Switch Fire /Smoke Damper Folding Shower Seat Feet (Foot) Fn Tube Flow Transmitter Footing Future Rre Valve Cabinet Fabric Wall Covering GROIN Natural Gas Gauge Gallon Galvanized Grab Bar Grade Clean Out Glazed CMU Garbage Disposal General Generator Gross Floor Area Ground Fault Interrupter Glass Fiber Reinforced Concrete Glycol —water Heating Return Glycol —water Heating Supply Galvanized Iron Glue Laminated Glass Glass Masonry Unit Ground Government al Glos Hour Gallo P Per er Mmute Guard Roil Grade Grille GaNanzed Rigid Conduit Gloss Reinforced Concrete Glass Reinforced Gypsum Plaster Galvanized Rigid Steel Gasoline Gate Valve Grease Waste Gypsum Wall Board Gypsum Height Hook One End Hose Bibb Handicap Hollow Cone Head Hand Dryer or Hair Dryer Hardboard Header Hardwood Hardware Hose End Valve High Intensity Discharge Hollow Metal Hand off Automatic Horizontal Heat Pump High Pressure Horsepower High Pressure Steam Return High Pressure Sodium High Pressure Steam Supply Handrail Hour Headstud High Strength Height Heating Heater Humidifier Heating Ventilating Unit Heating Ventilating and Air Conditioning Domestic Hot Water Domestic Hot Water Circulation Heating Hot Water Return Heating Hot Water Supply Heat Exchanger Hertz nfrared Burner ntercom nside Diameter overt Elevation Iluminating Eng. Society nside Face soloted Ground make Hood Isolation Joint In Joist Space Interco. Metal Conduit rich Include (trig) Insulation nterior on Pipe Indirect Waste Janitor Junction Box JunctionJST Joist Joint Keyed Construction Joint Keene's Cement Plaster Knockdown Kitchen Hood Kitchen Hood Exhaust Fan Kitchen Hood Supply Fan Kitchen Knock — out Kitchen Sink Kilovolt Kilovolt Amperes Kilovolt Amperes Reactive Kilowatt Kilowatt Hour An Lavator REVISION IAN LAM !AT LAV LB LBR IBS LD LDG LF LG IJN LINO LKR LL LLN LLA LOC LONG LPG LPR LPS LR LS LT LTG LV LW LWT MISC ML MLDG MLO MLWK MO MNT MPG MPR MPS MR MS MID MTG MTL MUL MV N/A NC NC NEC NUMB NEUT NIC NO NO NO NOM NS NTS to 0 BSC FC FCI FF FOI HP HT PG PP; OH S &Y TCS VHD X A AN D AR BS CD rF DI Laboratory Laminate(d) Leaving Air Temperature Lavatory Pound Lumber Pounds Load Loading Linear Foot (Feet) Length (Long) Unear Linoleum Locker Ave Load Long Leg Horizontal Long Leg Vertical Location Longitudinal Liquified Petroleum Gas Low Pressure Steam Return Low Pressure Steam Supply Living Room Lawn Sprinkler light Lighting Lower Long Way Leaving Water Temp. Minute MA Mixed Air MAC Machine MAG Magnetic MAG Magazine MAINT Maintenance MAN Manual Marker; Morkerbd Marker board MAS Masonry MAIL Material MAU Makeup Air Unit MAV Manual Air Vent MAX Maximum MB Machine Bolt MB Mop Basin MB; MBD Marker Board MBH /MBTUH Thousand BTU Per Hour MC Mechanical Comroctor MC Medicine Cabinet MCA Minimum Circuit Amps MCB Main Circuit Breaker MCM Thousand Circular Mans MD Manual Volume Damper MDF Medium Density Fiberboard MDO Medium Density Overlay MECH Mechanical MED CAB Medicine Cabinet MEMB Membrane MET Metal MEZZ Mezzanine MFR Manufacturer MARC Manufacturing MG Motor Generator MH Manhole MR. Metal Halide MH Mop Holder MEW Med Temp Heating Water Return MHWS Med Temp Heating Water Supply RH MIC;MICRO Microwave Oven (Residential Appliance) RN MIN Minimum RHC RH RHG RI &C RIDS RL RM RND RO RPBFP RPM RS RWL SA SA SAN OBS SC Sc SC SCD SCH SCHED SCR SCT SCUT SCW SD SD SO Out to Out SD Overall SE Outside Air SEC Obscure SECT On Center SECT Outside Diameter SENS Overflow Drain SEC/ Outside Face SF Overflow SF Owner Famished Contractor Installed SFCMU Owner Furnished Contractor Installed SFU Office SGL Owner Furnished Owner Installed OH Overhead Power SHEATH Overhead Telephone SHM Opening OHO Opposite; Opposite Hand SHW Outside Screw and Yoke SIM Open to Ceiling Space SL Overhead SLNT Oxygen SM Miscellaneous Motorized Louver Molding Main Lugs Only Millwork Masonry Opening Mount Medium Pressure Gas Medium Pressure Steam Return Medium Pressure Steam Supply Mirror Magnetic Starter Mounted Mounting Metal Mullion Mercury Vapor Nitrogen North Not Applicable New Normally Closed Nurse Call National Electric Code National Electrical Manufacturers Assn. Neutral Not In Contract Normally Open Number Nitrous Oxide Nominal Neutral Sensor Not To Scale Paint SM Pole SND Pressure /Temp. Test Port SNV Pump SP Public Address SP Panic Bolt SP Parallel SPEC Particle Board SPK Pull Box SPL Push Button Push Button Station Precast Pumped Condensate Paper Cup Dispenser Pounds Per Cubic Foot Pressure Drop Pump Discharge Plumbing & Drainage Institute BY APPROVED PENT Penthouse PERF Perforated PERP Perpendicular PF Power Factor PG Pressure Gage PH Phase PI Point of Intersection PI Pressure Indicator PIC Portable Instrument Connection PIV Post Indicator Valve PL Place(s) PL Plate P(AM;PL Plastic Laminate PLAS Plaster PLBG Plumbing. PLYWD Plywood PNEU Pneumatic PNL Panel PDC 'Point of Connection T Tempered PORC 'Porcelain T Thermostat PR Pair 'T & B Top &Bottom PREFAB Prefabricated T & G Tongue & Groove PROJ Projection T Tread PRV Pressure Reducing ANNA Tack; Tackbd Tack Board PS Pipe Support TAN Tangent PS .Projection Screen TB Terminal Box PSF Pounds Per OR Ft. TB Towel Bar PSI. Pounds per Sq. Inch TB,TBD Tack Board PST Pressure Safety Valve TC Temperature Control PT Paint TC Time Clock PT Pressure Treated TD Trench DrAN PT Point TDH Total Dynamic Head PT Potential Transformer TEL Telephone PTD Paper Towel Dispenser TEMP Tempered — Temporary PTD /R Combination Towel Dispenser /Recptacle TEMP Temperature PTN Partition TERR Terrazzo PVC Polyvinyl Chloride TEXT Textured PVI Point of Vertical Intersection TGL Toggle PVT Point of Vertical Tangency TH Threshold PWR Power. TH .Towel Hook THK Thick(riess) DT Quarry Tile TMR Olt Mirror Unit OTR RND Quarter Round T.O. Top of TOB Tap of Beam TOC Top of Concrete TOE Top of Footing TOIL Toilet TOP Top of Paving T0S Top of Steel Tap. of WaIBTR Trip Transverse Riser RA Return Air RAD Radiator RAD or R Radius RB. Rubber Base RC Remove Control RCP Reflected Ceiling Pion RCP Reinforced Concrete Pipe' RCU Reciprocating Chiller Joint RD Roof Drain RECP Receptacle REF Reference REEL Reflected REFR Refrigerant REFR;REF..' Refrigerator REG ' Register ROHE Reinforcement REM .Removable RED(D) Require(d) RESIL Resilient RET Retaining (wall) REV Revisions RF Return Fon Relative Humidity Relief Hood 'ReHeat Coil Robe Hook Refrigerant Hot Gas Rough In and Connect Rise in Joist Space Refrigerant Liquid Room Round Rough Opening Reduced Pressure Backflow. Preventer Revolutions Per Minute Refrigerant Suction Rain Water LeaaerS Sensor S Sink S Sanitary Sewer S Soap Dish South S Sprinkler tine Shock Absorber Supply Air Sanitary Waste Styrene. Butadiene Stryrene Security Solid Core Shower Curtain Seat Cover Dispenser Shower Curtain Hooks Schedule.' Shower Curtain Rod' Structural Clay Tile Scuttle Soft Cold Water Domestic Soap Dispenser. Smoke Damper Smoke Detector Storm Drain Steam Exhaust Vent Secondary Section Secretary Sensible Sequential Square Foot Supply Fan Split —Faced CMU Structural Facing Unit Single Shower Sheathing Security Hollow Metal Sheet Soft Hot Water Domestic Similar Short Leg Sealant Sheet Metal Sprinkler Main Sanitary Napkin Disposal Sanitary Napkin Vendor Static Pressure (H20) Stand Pipe Static Pressure Specifications Sprinkler Sound. Pressure Level SPL Special SPL BLK Splash Block. SO Square SS Stainless Steel SS Service Sink ST Stair ST Storm Sewer STAG'D Staggered STC Sound Transmission Class DATE STD STE STGR STL STOR STR SUB SUBFL SURF SUSP SV SV SW SW SWBD SWP SYM TRANS TRD Tseatl TS Temperature Sensor TS Tube Steel TOP Total Static Pressure TT Temperature Transmitter ITT Terrazzo Tile TTD Toilet Tissue Dispenser TV Television 1W Tack Wall IYP Typical UBC UC DG UGE UGT UH UL ONES UNFlN UNO UR URD US. Utility Shelf UBL Utilty UV Unit Ventilator ✓ VeAB Volt ✓ Vacuum VA Valve VAV Variable Air Volume VB Vapor Barrier VB Vinyl Base VCP Vitrified Clay Pipe VCT Vinyl Composition Tile VD Volume Damper — Manual VEL Velocity VENT Ventilation VENT Ventilator VERT Vertical VEST Vestibule VFD Variable Frequency Drive VIE erify In Feld W/0 WB WC WC WC WCC WCL WCO WD WDW WF WH WFMD WH WHM WI WLR WLS WMG WNSCT WP WPB WPF WPFG WR WR WSP WT WW Standard Single Tapered End Stringer Steel Storage Structural — Structure Substation Subfloor Surface Suspended Sheet Vinyl Solenoid Valve Short Way Switch Switch. Board Steam Working Pressure Symmetrical Urinal Uniform Building Code Unit Cooler Underground Underground Efectdcal Underground Telephone Unit Heater Underwriters Laboratories GAAARNvated Unfinished Unless Noted. Otherwise Urinal Underground Residential Distribution. Veneer. Plaster. Vacuum Pump Variable Speed Motor Controller Vinyl Tile Vent Through Roof Vinyl Wullcovering Vinyl Wall Protection p rawrivegg. Water Service Wide; Width Waste (Plug) Watt West Wide Range Washer (Residential Appliance) With Without Wet Bulb Wall Covering Water Column Water Closet Water Cooled Condenser Water Closet /Lavatory CorrSination Wall Clean Out Wood Window Wash Fountain Wall Hydrant Water Flow Measuring Device Water Heater Watt Hour Meter Wrought Iron Water Loop Return Water Loop Supply Water Motor. Gong' Wainscot Weatherproof Whidpaol Bath Waterproof Waterproofing Water Resistant Waste Receptacle Wet Standpipe Weight Warm White WINE Welded Wire Fabric XFMR Transformer XMTR Transmitter YD Yard YH Yard Hydrant Z Impedance ZCV Zone Control Valve ZVB Zone Valve Box • And ® At e. That is Number The following abbreviations are used with glazing: CG Clear Float. Glass CIS Clear Insulating Glass CTG Clear Tempered Float Glass COB Clear Tempered Insulating Glass LG Laminated Glass LOG Laminated Security Glazing SG Spandrel,Glass TG Tinted Float Glass O W Tinted Insulating Glass TUG Tinted Tempered Float Glass TWA Tinted Tempered Insulating Gloss WG Polished Wire Glass ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION I5 APPROVED APPROVED BY DEPT. DATE DRAWN CHECKED ENGINEER CHECKED APPROVED DATE GENERAL SYMBOLS NUMBER CROSS RE E FENCE ELEVATION ^ 0 `'! — LEGEND /KEY NOTE O COLUMN ENE INTERIOR ELEVATION ROOM NUMBER O DOOR NUMBER SHEET ON WHICH DRAWN SHEET ON WHICH REFERENCED Y— BUILDING CRO55 SECTION'., \ SECTION DETAIL SECTION SOIL GRAVEL SAND CONCRETE WOOD ( FRAMING / BLOCKING ® LARGE ( S CALE) I LARGE SCALE) ONTINUOUS BLOCKING WOOD (TRIM /FINISH) ME1T1i1 RIO MASONRY "'I OR BRICK VENEER METAL STUDS TEEL LSARGE SCALE) PLYWOOD LARGE SCALE GYPSUM WALL BOARD LARGE SCALE BATT INSULATION RIGID INSULATION �p�yylIIlll� lilli. URGE ACOUSTICAL TILE W -LLLVJ LARGE SCALE ® LARGE SC SUBTITLE TITLE ABBREVIATIONS AND SYMBOLS BUILDING 9-96 TENANT IMPROVEMENT #4 BUILDING 9 -96 CURRENT REVISION J #715225 -00 SHEET JOB ''N0 SYMBOL G2 J #715225 -00 DATE 08.10.01 COMP NO. SAM A BLDG 9 -96 STRUCTURAL UPGRADE BLDG 9 -96 EARTHQUAKE REPAIR BUILDING 9 -96 T.I. #4 REVISION __12x12 RAG (TYP) • AIR CELL 125 • CFM /12 T GRILLE 13/12 23/12 36/14'1 L1`.f 44/20 BLANK OF THIS INLET 12 6 �c a 23/12 100 12/ PRESSURE TEST EACH AIR CELL AT SUPPLY TAPS SERVING MIXING BO REMOVE EXISTING THERMOSTAT FROM WALLS BEING REMOVED. HANG STAT ON ZONE MIXING BOX FOR FUTURE 1M15 J #715225 -00 J #715225 -00 J#715225 -00 BY DLR GROUP DLR GROUP DLR GROUP APPROVED RP RP RP DATE 03.08.01 06.28.01 08.10.01 SYM REVISION BY APPROVED FLOOR PLAN SCALE: 1/8 " =1' -0" DATE i r�n7_1A- I. L� 1161 -I- ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT.' DATE DRAWN K:BUN CHECKED A NOINE88 CHECKED APPROVED DATE 8 - 8 - 96 51 REMOVAL HVAC - PLAN BUILDING 9-96 T.I. #4 BUILDING 9 -96.1 LEGEND: 2 2 DUCT, SINGLE UNE 0 2- [V 2 CI - DUCT LINER; SOUND CONTROL Q THERMOSTAT; ELECTRIC GENERAL NOTES: CEILING DIFFUSER, ARROW INDICATE AIR THROW LINEAR DIFFUSER AND CFM AIR FLOW WALL OR DUCT MOUNTED GRILLE OR REGISTER VOLUME DAMPER ZONE & BYPASS DAMPER; WT SYSTEM CONSTRUCTION NOTES: REMOVE ALL LIGHT - TROFFER STYLE DIFFUSERS AND ASSOCIATED BRANCH DUCTS FOR THIS ZONE. EXISTING MIXING BOX AND PLENUM TO REMAIN. EXIST. DIFFUSERS OR MIXING BOX WLL INTERFERE WITH NEW X -BRACE LOCATION. REMOVE AND RETAIN FOR REINSTALLATION PER 1M10. EXIST. DUCTWORK CONFLICTS WITH NEW X -BRACE LOCATION. REMOVE DUCTS MINIMUM OF 7 - BOTH NORTH AND SOUTH OF GRIDUNE. 7 TO FACILITATE REISTALLA110N PER 1M10. EXIST. MIXING BOX AND DISTRIBUTION SYSTEM (DUCTWORK & DIFFUSERS) WILL BE IN THE WAY OF CONSTRUCTING X- BRACE. REMOVE AND RETAIN FOR REINSTALLATION IN SAME LOCATIONS. EXIST. DIFFUSER CONFLICTS WITH NEW X -BRACE CONSTRUCTION_ REMOVE AND RETAIN FOR REINSTALLATION IN SAME KEY' PLAN SCALE NONE ... CURRENT REVISION. 'SYMBOL 4715225 -001 SHEEP JOB NO. 1 1 O R .,417199—nn 0 COMP NO. 08.10.01 SYM A ADD VAV BOX FPI A yew AP i a i°g rs l�i I� IIIr�1i�� '/ S GfiJli.'L:9 ►/�0�►. G �hvo, i 0 _,., 12x12 100 1 • ati, w D 1 10 "✓ e+�� " 220(CF A A 2.il Etz, 320 0 4 M (2 TYP) 19/12 17/12 110 350 CFM D -1 10'4 1x121 135 RAG '13 IIIMEUMN s 1 3 ►. 24 x'2 RAG -1 2 TYP RELOCATE DIFFUSER 0 0 REVISION BUILDING 9 -96 T.I. - PROGRESS PRINT J #160163 -08 J #771971 -L0 J #703445 -05 BY DMV HARRAH DLR GROUP 0 °0 ® 0 APPROVED 01.26.01 SYM BUILDING 9 -96 T.I. #3 BUILDING 9 -96 T.I. #4 REVISION BUILDING 9 -96 EARTHQUAKE REPAIR FLOOR PLAN SCALE: 1/8 i' -0" J #715225 -00 4715225 -00 J #715225 -00 10/8 - BY DLR GROUP DLR GROUP DLR GROUP CAP APPROVED RP RP RP DATE 06.28.01 07.27.01 08.10.01 0 0 elArizezAv. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K.BUN TNECKED ENGINEER CHECKED APPROVED 0 0 o" co M DATE 8 -8 - 96 DLE HVAC - PLAN TITL BUILDING 9-96 , TENANT IMPROVEMENT # BUILDING 9 -96.1 LEGEND: 2 2 DUCT, SINGLE LINE REMOVAL L 2 2 FC0 2 0 1 FLOOR CLEAN —OUT 2 D1 2 PRESSURE REGULATOR �} THERMOSTAT; ELECTRIC GENERAL NOTES: CURRENT REVISION J #715225 -00 SHEET JOB NO. PRESSURE TEST EACH AIR CELL AT SUPPLY TAPS SERVING MIXING BOX. CEILING DIFFUSER, ARROW INDICATE AIR THROW LINEAR DIFFUSER AND CFM AIR FLOW WALL OR DUCT MOUNTED GRILLE OR REGISTER VOLUME DAMPER ZONE & BYPASS DAMPER; WT SYSTEM DUCT LINER; SOUND CONTROL CONSTRUCTION NOTES: 1:>- ALL LIGHT- TROFFER STYLE DIFFUSERS AND ASSOCIATED BRANCH DUCTS FOR THIS ZONE EXISTING MIXING BOX AND PLENUM TO REMAIN_ .7 nn WILL INTERFERE WITH NEW X— BRACE LOCATION. REMOVE AND RETAIN FOR REINSTALLATION PER 1M10. EXIST. DUCTWORK CONFLICTS WITH NEW X —BRACE LOCATION_ REMOVE DUCTS MINIMUM OF 7' -0" BOTH NORTH AND SOUTH OF GRIDLINE. 7 TO FACILITATE REISTALLATION PER 1MI0_ EXIST. MIXING BOX AND DISTRIBUTION SYSTEM (DUCTWORK & DIFFUSERS) WILL BE IN THE WAY OF CONSTRUCTING X— BRACE. REMOVE, AND RETAIN FOR REINSTALLATION IN SAME LOCATIONS_ EXIST. DIFFUSER CONFLICTS WITH NEW X —BRACE CONSTRUCTION. REMOVE AND RETAIN FOR N IN SAME LOCATION REMOVE EXISTING THERMOSTAT FROM WALLS BEING REMOVED. HANG STAT ON ZONE MIXING BOX FOR FUTURE SYMBOL 11R DATE COMP NO. 08.10.01 REMOVE CEILING DIFFUSER- PRESSURE TEST EACH AIR CELL AT SUPPLY TAPS SERVING MIXING BOX SYM A B2 CONSOLIDATION 12 10� B+ ZI _ mac: - 12/10 12 1/2/12 Rs� 13/12 23/12 araiortree 0 CFM /12 T GRILLE g � �� '��� ►7� 36/14 �35// Aot u 48/ 0 I�� ' I '''L -' = `'' —I■®�'��l � K A - o J 80 0 1 E��. . �. ler £•? Ilium, — Ei � 144 © l� 36/14 100 135 21 12 13 FE' ' CHECKED CHECKED 0 0 2M14 DATE 08.10.01 REVISION BLDG 9 -96 STRUCTURAL UPGRADE BLDG 0 -96 EARTHQUAKE REPAIR O O J #157117 -00 J #703445 - 05 41715225 -00 BY DMV DLR GROUP DLR GROUP O APPROVED RP RP 03.08.01 06.28.01 YM O " Q REVISION APPROVED DATE si,LArOE /NG° ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. BUN PROVED TIRE HVAC -'PLAN BUILDING 9 -96? TENANT IMPROVEMENT #4 R1111 min 9 -AA 9 LEGEND: 0 t 2 O CEILING DIFFUSER, ARROW INDICATE AIR THROW LVD DUCT, SINGLE LINE LINEAR DIFFUSER AND CFM AIR FLOW WALL OR DUCT MOUNTED GRILLE OR REGISTER VOLUME DAMPER ZONE & BYPASS DAMPER; WE SYSTEM DUCT UNER; SOUND CONTROL FCO 0 t FLOOR CLEAN -OUT L' t PRESSURE REGULATOR Q THERMOSTAT; ELECTRIC GENERAL NOTES: JOB NO. CONSTRUCTION NOTES: REMOVE ALL UGHT- TROFFER STYLE DIFFUSERS AND ASSOCIATED BRANCH DUCTS FOR THIS NE EXISTING MIXING BOX CI CURRENT REVISION SYMBOL J #7.15225 -00 SHEEP 2M1OR XING BOX WILL INTERFERE WITH NEW X -BRACE LOCATION. REMOVE AND RETAIN FOR REINSTALLATION PER 1M10. EXIST. DUCTWORK CONFLICTS WITH NEW X -BRACE LOCATION. REMOVE DUCTS MINIMUM OF 7-0' BOTH NORTH AND SOUTH OF GRIDLINE. 7 TO FACILITATE REISTALLA110N PER 1M10. EXIST. MIXING BOX AND DISTRIBUTION SYSTEM (DUCTWORK & DIFFUSERS) WILL BE IN THE WAY OF CONSTRUCTING X- BRACE. REMOVE AND RETAIN FOR REINSTALLATION IN SAME LOCATIONS. EXIST. DIFFUSER CONFLICTS WITH NEW X -BRACE CONSTRUCTION. REMOVE AND RETAIN FOR REINSTALLATION IN SAME LOCATION. REMOVE EXISTING THERMOSTAT FROM WALLS BEING REMOVED. HANG STAT ON ZONE MIXING BOX FOR FUTURE 26115 KEY PLAN 0 SCAM NONE N COMP NO. SY A INSTALL VAV BOXES BLDG 9 -96 STRUCTURAL UPGRADE BLDG 9 -96 EARTHQUAKE REMOVAL REVISION J #701888 -00 J #703445 - 05 41715225 -00 BY DMV DLR GROUP OUR GROUP APPROVED RP RP DATE 07.25.00 03.08.01 06.28.01 SYM REVISION FLOOR PLAN SCALE: 1/8 " =1' -0" BY APPROVED p riterAc - Iriaw. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN K. BUN CHECKED ENGINEER CHECKED APPROVED DATE 8 - 8 - 96 SUBTITLE HVAC - PLAN TDL BUILDING 9 -96 TENANT IMPROVEMENT # BUILDING 9 -96.2 LEGEND: 1 LV D o FCO 0 PRESSURE TEST EACH AIR CELL A SUPPLY TAPS SERVING MIXING BOX. EXIST. MIXING BOX AND DISTRIBUTION SYSTEM (DUCTWORK & DIFFUSERS) WILL BE IN THE WAY OF CONSTRUCTING X— BRACE. REMOVE AND RETAIN FOR REINSTALLATION IN SAME LOCATIONS. 2 I" 2 PRESSURE REGULATOR CO THERMOSTAT; ELECTRIC GENERAL NOTES: CURRENT REVISION J#71 5225 -00 SHEET JOB N DUCT, SINGLE LINE CEILING DIFFUSER, ARROW INDICATE AIR THROW LINEAR' DIFFUSER AND CFM AIR FLOW WALL OR DUCT MOUNTED GRILLE OR REGISTER VOLUME DAMPER ZONE & BYPASS DAMPER; WE SYSTEM DUCT LINER; SOUND CONTROL FLOOR CLEAN —OUT CONSTRUCTION NOTES: REMOVE ALL LIGHT—TROFFER STYLE' DIFFUSERS AND ASSOCIATED BRANCH DUCTS FOR THIS ZONE. EXISTING MIXING BOX AND PLENUM TO REMAIN. VE LING FFUSER E T. 1 S WILL INTERFERE 4NTH NEW X —BRACE LOCATION. REMOVE AND RETAIN FOR REINSTALLATION PER 1M10. EXIST. DUCTWORK CONFLICTS WITH NEW X —BRACE LOCATION. REMOVE DUCTS MINIMUM OF 7' -0" BOTH NORTH AND SOUTH OF GRIDUNE. 7 TO FACILITATE 1M10 S ONFUCTS WITH NEW X -BRACE CONSTRUCTION. REMOVE AND RETAIN FOR REINSTALLATION IN SAME 0 ® REMOVE EXISTING THERMOSTAT FRO WALLS BEING REMOVED. HANG STAT ON ZONE MIXING BOX FOR FUTURE SYMBOL 1ll7151ST_nn DATE 08.10.01 COMP N0. SAM A BLDG 9 -96 STRUCTURAL UPGRADE BLDG 9 -96 EARTHQUAKE REPAIR BUILDING 9 -96 T.I. # °111111111 i■illlll Ogi 2 TON ° LIEBER MINI -MATE 885 CFM 208V, 1 PH, 60N AC2K13 1ST WriP CEILING DIFFUSER TUTTLE & BAILEY CTL4 -2408 (TYP) 250 CFM SEE NOTE 3 SEE NOTE 1 NOTE 2 6 "x12" EXHAUST AIR WAVE GUIDE AIR VENT. SS DETAIL 750 CFM 24x12' REG CAD B REVISION FM RETURN GRILLE (24x24) CTRL4- 2422 TUTTLE & BAILEY (TYP) J #703445 -05 J #715225 - 00 J #715225 -00 50 CFM 60 BY DLR GROUP DLR GROUP DLR GROUP APPROVED 03.08.01 RP RP DATE 06.28.01 07.27.01 SYM SEE NOTE 3 REVISION 36/16 FLOOR PLAN SCALE: 1/8"=1 -0' APPROVED DATE Zi.trizEirAr.G. ACCEPTABILITY THIS DESIGN AND /OR. SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE CHECKED REM OVAL HVAC - PLAN BUILDING 9 -96 TENANT IMPROVEMENT #4 RIIII fIN(4 A -AA 9 LEGEND: r } DUCT, SINGLE LINE Q CEILING DIFFUSER, ARROW INDICATE AIR THROW LINEAR DIFFUSER AND CFM AIR FLOW WALL OR DUCT MOUNTED GRILLE OR REGISTER i [ VOLUME DAMPER ZONE & BYPASS DAMPER; WT SYSTEM 0 I-J Fl DUCT LINER; SOUND CONTROL FCO 1 o 1 FLOOR CLEAN -OUT 1 l" r PRESSURE REGULATOR 0 THERMOSTAT; ELECTRIC GENERAL NOTES: CURRENT REVISION. J #715225 -00 SHEEP' CONSTRUCTION NOTES: REMOVE ALL UGHT-TROFFER STYLE DIFFUSERS AND ASSOCIATED BRANCH DUCTS FOR THIS ZONE. EXISTING MIXING BOX AND PLENUM TO REMAIN_ REMOVE CEILING DIFFUSER. PRESSURE TEST EACH AIR CELL AT SUPPLY TAPS SERVING MIXING BOX. ® EXIST. DIFFUSERS OR MIXING BOX WILL INTERFERE WITH NEW X -BRACE LOCATION. REMOVE AND RETAIN FOR REINSTALLATION PER 1M10. EXIST. DUCTWORK CONFLICTS WITH NEW X -BRACE LOCATION. REMOVE DUCTS MINIMUM OF 7 - BOTH NORTH AND SOUTH OF GRIDLINE. 7 TO FACILITATE REISTALLATION PER 1M10. © EXIST. MIXING BOX AND DISTRIBUTION SYSTEM (DUCTWORK & DIFFUSERS) WILL BE IN THE WAY OF CONSTRUCTING X- BRACE. REMOVE AND RETAIN FOR REINSTALLATION IN SAME LOCATIONS. EXIST. DIFFUSER CONFLICTS WITH NEW X -BRACE CONSTRUCTION. REMOVE AND RETAIN FOR REINSTALLATION IN SAME LOCATION. ' REMOVE EXISTING THERMOSTAT FROIu WALLS BEING REMOVED. HANG STA ON ZONE MIXING BOX FOR FUTURE SYMBOL D 2T R JOB NO. „�,.���� KEY PLAN SCALE NONE DATE 08.10.01 COMP N0. L_ AN op II ZILArate ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DATE (, iv(} % IN ) CONSTRUCTION NOTES: REMOVE DRINKING FOUNTAIN. TEMPORARILY CAP W, V, & CW SUPPLY. DEPT. ENGINEER CHECKED I ui REVISION A BUILDING 9 -96 T.I. #4 J #715225 -00 DLR GROUP APPROVED 08.10.01 RENSIGN APPROVED DRAWN HHE' CHECKED, DATE 08.08.01 1M112 1M113 1M115 1ST FLOOR PLUMBING REMOVAL PLAN BUILDING 9 -96 TENANT IMPROVEMENT #4 PIIII nlnln a_OA 1 CURRENT REVISION J #715225 -00 SHEET JOB N0. 1M11OR DATE 08.10.01 COMP NO. SYM A BUILDING 9-96 T.I. #4 !T, 1- REVISION 4715225-00 BY DLR GROUP APPROVED RP DATE 08.10.0 SYM L REVISION I d BY APPROVED 7 ABL DEMO. ROOM DATE e ACCEPTABILITY HIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN FINE CHECKED ENGINEER CHECKED APPROVED DATE 08.08.01 OVAIJ moi-141 s'T'E FLOOR PLUMBING REMOVAL PLAN BUILDING 9-96 TENANT IMPROVEMENT #4 BUILDING 9-96.1 [>- REMOVE DRINKING FOUNTAIN. TEMPORARILY CAP W, V. SUPPLY. 0zAv‘ 0.1 1.0 CURRENT REVISION SYMBOL A J#715225-00 SHEET 1M111R j°B ND ATE 08.10.01 COMP NO SY A REDRAWN BLDG 9 -96 STRUCTURAL UPGRADE BUILDING 9 -96 T.I. #1 REVISION J #703445 -05 J #715225 -90 BY KB LR GROUP LR GROUP APPROVED RP RP DATE 03.08.01 06.29.01 SYM TT 1) BUILDING 9 -96 T.I. #4 REVISION SCALE: 1/8 " =1' -0" FLOOR PLAN J #715225 -00 BY 1 ' DLR GROUP APPROVED RP DATE 08.10.01 AFATIFAriVig® i T DEPT.' DATE CHECKED APPROVED ACCEPTABILITY 11 BUN DATE THIS DESIGN AND /OR CHECKED SPECIFICATION IS APPROVED R. SQUIRES 8 -8 -96. ENGINEER EMOVAL 141 PLUMBING - PLAN TITS BUILDING 9 -96 TENANT IMPROVEMENT #4 BUILDING 9-96.1 LEGEND: GENERAL NOTES: CONSTRUCTION NOTES: REMOVE EXISTING WALL -HUNG LAVATORY. i V/i-eof CITY CURRENT REVISION J #715225 - 00 SHEET 1M114R JOB NO.. 11171 nn COMP NO. SYM A REDRAWN REVISION BLDG 9 -96 STRUCTURAL UPGRADE BUILDING 9 -96 T.I. #1 J #703445 -05 J #715225 -00 BY KB DLR GROUP DLR GROUP APPROVED RP RP DATE 03.08.01 06.29.01 SYM REVISION SCALE: 1/8 " =1' -0" FLOOR PLAN BY APPROVED DATE gLAriarAtErAw APPROVED BY ACCEPTABILITY THIS DESIGN AND /OR SPECIRCATION IS APPROVED DEPT: DATE DRAWN K. BUN CHECKED R. SQUIRES 1.NUINEER CHECKED APPROVED DATE 8 -8 -96 8 -8 -96 SUE..E MO1 -141 PLUMBING - PLAN OLE BUILDING 9-96 TENANT IMPROVEMENT #4 BUILDING 9 -96.1 LEGEND: GENERAL NOTES: CONSTRUCTION NOTES: REMOVE DRINKING FOUNTAIN. TEMPORARILY CAP W, V, &CWSUPPY. REMOVE AND RETAIN EXISTING URINAL FOR REINSTALLATION' APPROXIMATELY 7" LOWER THAN CURRENTLY. EXISTING CW & W CONNECTION Rift REQUIRE MODIFICATION TO MATCH NEW LOCATION. REMOVE WALL -HUNG LAVATORY. CURRENT REVISION J #715225 -00 SHEET 1Ni115R JOB NO. OMP NO. SYMBOL DATE D 08.10.01 (K) Z ® lJ 35039 ACCEPTABILITY 1MS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY 'DEPT. (Lb 1 11 CONSTRUCTION NOTES: REMOVE DRINKING FOUNTAIN. TEMPORARILY CAP W, V, & CW SUPPLY. REMOVE URINAL. CAP W & CW SUPPLY REMOVE WATER CLOSET. CAP W & CW SUPPLY. REMOVE LAVATORY. CAP W & CW SUPPLY. z all I11j 1 3 LEGEND: GENERAL NOTES: ASBESTOS NOTIFICATION A BUILDING 9 -96 T.I. #4 REVISION J #715225 -00 DLR GROUP 08.10.01 REVISION APPROVED DRAWN DATE S HHE 08.08.01 CHECKED CHECKED 2ND FLOOR PLUMBING REMOVAL PLAN CURRENT. REVISION J #715225 -00 SHEET JOB NO. 2M111 2M112 2M113 2M114 2M115 08.10.01 MO1_1 41 BUILDING 9-96 TENANT IMPROVEMENT #4 Rilil (11NC;' A —AR 9 KEY PLAN' SCALE; NO. COMP N0. SYM A BUILDING 9-96 T.I. 1/4 REVISION 4715225 BY DLR GROUP F APPROVED RP DATE 08.10.01 SYM 1 _ I REVISION 73 LAN BY : m APPROVED DATE 4LAGrar APPROVED BY DEPT. DATE (N ) -. . 1 .1 I As 0 1 a Ir nfi .. ACCEPTABILITY DRAWN HHE 08.10.01 THIS DESIGN AND/OR ZWCKED SPECIFICATION IS APPROVED I • CHECKED DATE 2ND FLOOR PLUMBING REMOVAL PLAN TITLE BUILDING 9-96 TENANT IMPROVEMENT #4 P1111 mint 0-0A 0 CONSTRUCTION NOTES: [I• REMOVE DRINKING FOUNTAIN. TEMPORARILY CAP W, & CW SUPPLY. CTf !! ' CURRENT REVISION SYMBOL 4715225-00 A SHEET JOB NO. 2 111R KEY PLAN 0 sc.: NONE DATE 08.10.01 COMP NO. SYM A c CD 0 BUILDING 9-96 T.I.#2 BUILDING 9-96 T.I.#3 BUILDING 9-96 T.I.#4 REWSION fL 4715225-00 4715225-00 4715225-00 BY DLR GROUP DLR GROUP DLR GROUP APPRO. RP RP RP DA. 07.13.01 07.27.01 08.10.01 SYM 00 ® 80 0 RP/ISION FLOOR PLAN SCALE: 1/8=1-0" BY APPRO. DATE e ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. 00 DATE DRAWN DLit GROUP CHECKED eNGINEEK CHECKED APPROVED 07.13.01 UBTITLE J R MO 1 ' REM OVAL PLUMBING - PLAN BUILDING 9-96 TENANT IMPROVEMENT #4 P1111 DNA gl-flA 9 GENERAL NOTES: CONSTRUCTION NOTES: [I27= REMOVE WALL—HUNG LAVATORY. E:>- REMOVE AND RETAIN EXISTING URINAL FOR REINSTALLATION APPROXIMATELY 7" LOWER THAN CURRENTLY. EXISTING CW & W CONNECTION WILL REQUIRE MODIFICATION TO MATCH NEW LOCATION. CUR SYMBOL C SHEET 2M114R 0 — 0 0 0 0 KEY PLAN sULD NONE DATE COMP NO. 08.10.01 A BUILDING 9 -96 TI #2 BUILDING 9 -96 T.I. #3 BUILDING 9 -96 T.I. #3 0 REVISION J #715225 -00 J #715225 -00 J #715225 -00 BY DLR GROUP DLR GROUP DLR GROUP APPROVED RP RP RP DATE 07.13.01 07.27.01 08.10.01 SYM REVISION C �® FLOOR PLAN SCALE: 1 /8 " =1'- DN APPROVED DATE eifiroLsrArw. ACCEPTABILITY THIS DESIGN AND /OR SPECIFIGA11ON IS APPROVED DEPT DATE DRAWN DLR GROUP ORROKED ENGINEER CHECKED APPROVED DATE 07.13.01 (30 PLUMBING PLAN TITLE BLDG 9-96 TENANT IMPROVEMENT #4 BUILDING 9 -96.2 LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES REMOVE EXISTING DF AT THIS LOCATION. CAP W, V AND CW SERVICES. REMOVE WATER CLOSET AND ALL ACCESSORIES TO THE WALL. CAP CW AND W FLUSH TO WALL. REMOVE AND RETAIN EXISTING URINAL FOR REINSTALLATION APPROXIMATELY 7" LOWER THAN CURRENTLY. EXISTING CW & W CONNECTION WILL REQUIRE MODIFICATION TO MATCH NEW LOCATION. ® REMOVE WALL -HUNG LAVATORY. JOB NO. iJl -�a rnn CURRENTREVISION SYMBOL J #715225 - 00 SHEET 2M115R DATE 08.10.01 COMP N0. SYM A D- 200 CFM 10 "0 D -1 400 CFM (2 TYP) RAG -1 8 "0 D -1 � 320 CFM 8 "0 D -1 320 CFM 8 "0 D -1 200 CFM 0 8 "0 D -1 �N\ 360 CFM RAG- 10 "0 D- R 10 "0 400 IFM �© 800 (2 TY )� % 8 "0 D -1 U 8 "0 D -1 2 320 FM 10..0 35 FM / 1 8 "0 D -1 8 "0 200 CFM 200 C M 2 0 CFM :.i t0 "0 D -1 400 CFM • BLAN THIS I A 8 "0D 1 8 "0 D-1 320 CFM RAG -1 10'0 D -1 400 GEM 8 "0 D_1 10 "0 D -1 400 CF (2 TY RAG h 7 - _ 320 CFM • j 4 8 "0 D-1 *6"41 CFM RAG -1 10 "0 N OFD' 8 "0 D -1 315 CF 8 "0 D -i LT — 295 CFM � , DFr2;FTYP RAG �jc, :- I S g OlB 2 `, =i ! II r 10 0 10 "4 \ 1� ® 6Pl "0 D -1 10"0 15 CFM �� 2 TYP) 10 "0 iR© co u mmilm I• 12 10 390 CFM 10N x' y ' 10 "0 D- Ii00 CFM (2 TYPI 13/12 23/12 WOMEN'S 01G05 425 E1 2 RET e•ILLE.p E'>Vv y AOeeL 0 D -1 00 CF 80 rrimplr 1 320 CFM 44/20 =MI IMM El IllimaUNIM,11 11 10 "o V 10 "0 10 "0 350 D-1 11 111111111 (31YP) RAG 7 A C � 10 "0 a o 10 "0 D -1 CFM P) MS; 24'X2 E> ABANDON IN PLACE • BOX CFM TOTAL CFM 1. D -1, = TITUS D -2 = TITUS RAG- = I S OR ( 0 M521 1M10 D OR Ank 0 NEW STRUCTURAL X -BRACE IN THIS LOCATION. REROUTE EXISTING DUCTWORK, AND PROVIDE NEW DUCTWORK AS REQUIRED. NEW THERMOSTAT NEW RETURN AIR GRILLE BLDG 9 -96 STRUCTURAL UPGRADE BUILDING 9 -96 T.I. #4 REVISION J #703445 -05 J #715225 -00 BY DLR DLR GROUP APPROVED RP RP DATE 03.08.01 08.10.01 SY REVISION FLOOR PLAN SCALE: 1/8"=1'-0" APPROVED DATE Z ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K.BUN CHECKED CHECKED 8 -8 - 96 SUBTITLE HVAC - PLAN TIT BUILDING 9 -96 TENANT IMPROVEMENT # R1111 mIN( 4 -4R 1 LEGEND: 1 1 DUCT, SINGLE LINE O CEILING DIFFUSER, ARROW INDICATE AIR THROW 1 L 1 FS GENERAL N Co SST` lC !N NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING DUCTWORK IS NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MIXING BOXES ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST BRACE EQUIPMENT PER NEW DIFFUSER AND RUNOUT DUCTWORK CAP EXISTING DUCTWORK. BRACE PER 1M1 LOCATION NEW TAP. C 10 CUT & CAP EXISTING TAP. 11 CONNECT NEW 24 "X10" AT GRIDLINE A OF 9 -90 BLDG. EXTEND TO NEW CHASE. CONT. UP WALL OR DUCT MOUNTED GRILLE OR REGISTER VOLUME DAMPER DUCT LINER; SOUND CONTROL THERMOSTAT; PNEUMATIC WALL MOUNTED THERMOSTAT AIR CELL CONNECTION FIRE SMOKE DAMPER CURRENT REVISION SYMBOL J #715225 -00 SHEET JOB N 0. 1M 1 0 "LAY -IN OR EQUAL. 1" SLOT, 36" L 24" "X24" LAY -IN OR EQUAL 1M10 M521 NE IXING BOX Q 8 M521 lM10 DATE OR COMP' NO. 4 08.10.01 M521 YM A RELOCATE DIFFUSER ADD VAV BOX 10"4\ w r, 320 CFM RAG -1 10 "4 D -1 400 CFM (2 TYP)w 8 "4 D -1 10 "4 D- 400 CFM AIR CELL 1 „ � 8 "0 D -1 ^'CFM 10 "0 D -1 400 C 8 "0 D -1 320 CFM 8 "4 D -1 19/12 +1 CAP 320 CFM 320 CFM AIR CELL 10 °0 RAG- 8 "4 D- 350 CF (3 TYP) RA —1 r „ 8 "6 D- 237 CF (4 TYP) 2 � \ 4 1 \ r _ 4 D - 1 \ 6 ® © 180 - ®1 Ih'� N © ( TYP) 91 �R \� fr 22/74 8 0 D -1 o I! RAG -1!d k 200 CFM 8" m RAG - 1 CFM (2 TYP) y � l (1� _ -• 4 aF11_ W M 9' 150 ?gip A i bi. IP.0.-- BA' L E ' `.. ri 1 _IATE -S lJ RAG -? ©I s �. R AG 1 ii III -4114 11P--a 8 "0 D (3 TYP) rA 1 p "� �i- Q ili.r \G 6: D AN'�� - � '210 � FF; C= / � q �� � (2 GYP ��.A)u_t la !WI 3 ' 00 10"4 M� 8 "w D - 320 CFM iu S EETING ROOM CAP OUTLET$ (TYP 6) 7o c 18/12 11 "4 , CF 1�0 C :....'iii I 16t � AP (2 TYP (g�s 1 „imp V A 100 / r 90 N I 1 '1 8 "0 D -1 320 CFM "4D -1 150 CFM RA 320 CFM BUILDING 9 -96 T.I. - PROGRESS PRINT REVISION J #160163 -08 J #771971 -L0 J #703445 -05 8Y DMV HARRAH DLR APPROVED DATE 1 - 26 - 01 SYM BULDING 9 -96 T.I. #3 BUILDING 9 -96 T.I. #4 REVISION J #715225 -00 J #715225 -00 10/8 - BY DLR GROUP DLR GROUP APPROVED RP RP DATE 07.27.01 08.10.01 �BOE /NG° ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT DATE DRAWN K.BUN CHECKED E GiNEEER CHECKED APPROVED 8 - 8 - 96 01 -141 HVAC - PLAN TITLE BUILDING 9 -96 TENANT IMPROVEMENT #4 BUILDING 9 -96.1 GENERAL 1. D -1 = TIT D -2 = TITU RAG -1 = 11 LEGEND: 1 1 DUCT, SINGLE LINE L VD 1> ABANDON IN PLACE O CEILING DIFFUSER, ARROW INDICATE AIR THROW WALL OR DUCT MOUNTED GRILLE OR REGISTER VOLUME DAMPER ZONE & BYPASS DAMPER; VW SYSTEM DUCT LINER; SOUND CONTROL THERMOSTAT; ELECTRIC WALL wALL MOUNTED THERMOSTAT AIR CELL CONNECTION FIRE SMOKE DAMPER 4 "LAY -IN OR EQUAL_ ) 1" SLOT, 36" L 4” "X24" LAY -IN OR EQUAL CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING DUCTWORK IS NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MIXING BOXES ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. BRACE EQUIPMENT PER 1M111M521 NEW DIFFUSER AND RUNOUT DUCTWORK. CAP EXISTING DUCTWORK. EW : TU R NEW STRUCTURAL X -BRACE IN THIS LOCATION_ REROUTE EXISTING DUCTWORK PER RELOCATE EXISTING DIFFUSER OR MIXING BOX TO THIS LOCATION. INSTALL NEW DUCTWORK AS REQUIRED. (ORIGINATED FROM ON 1M11R.) NEW THERMOSTAT EXTEND DUCTWORK TO NEW MIXING BOX LOCATION. NEW FIRE SMOKE DETECTOR IN HORIZONTAL PLANE OF RATED CONSTRUCTION. PROVIDE SMOKE DETECTOR TO OPERATE SMOKE NI> RELOCATE MIXING BOX TO NOT WITHIN EXIT CORRIDOR. PROVIDE FIRE /SMOKE DAMPER AS INDICATED. PROVIDE SMOKE DETECTOR. [it FIELD VERIFY USEFULNESS. CONSULT WITH MECHANICAL ENGINEER. 1M12 1M15 0 0 1M10 1M13 1M14 op s tl roO k Au CURRENT REVISION J #715225 -00 SHEET JOB N0. KEY PLAN SYMBOL 1M11 DATE COMP NO. 08.10.01 A 10 "4 8 "4 D -1 110 270 CFM 0 "4 8 "0 D- 235 CFM (2 TYP) 48/20 8 "0 D -1 270 CFM 8 ",\D -1 320'cFM 8"0 D -1 10 "4 375 CFM 8"4 D -1 375 CFM RAG -1 8 "4 D -1 320 CFM 8 "0 D -1 270 CFM 8 "0 D -1 !,.EFFF .. FM RAG -1 10 "4 -1 400 C MD! 675 CFM 24/12 RET GRILLE., .N'3 13/12 _13/12 i 425 24/1 STAIF 10 "4 0- 235 CFM - TYP) 6 "4 D -1 60 160 CFM 6/14 8 "0 D -1 235 CFM (2 TYP) 8 "0 D -1 8 "0 D -1 0"0 8 "4 D -1 320 C 8' D -1 271 CFM ..RAG- '4i-,!\\ 10"0 D -1 401 M g ®% 8 "0 D -1 270 CFM 8''0 D -1 320 CFM AG -1 8 "0 D -i 270 C F j w eI.a11 '111 . 1 0CFM R:T GRILLFOME ' LEI O I i �� s�s "0 D -1 6 "0 D 1 550 FM 10 "0 al;o 11 0131 L fr i r 48/20 8 "0 D 8 "0 D -1 366 CFM ( IYP) 375 CFM 10 ' 4 D -2 B2 CONSOLIDATION BUILDING 9 -96 T.I. #4 REVISION BLDG 9 -96 STRUCTURAL UPGRADE J #157117 -00 J #703445 -05 4715225 -00 BY DMV DLR GROUP DLR GROUP APPROVED DATE RP RP 03.08.01 08.10.01 SYM REVISION 0 APPROVED DATE �BOE /A/G' ACCEPTABILITY THIS DESIGN. AND /0R SPECIFlCAi10N IS APPROVED APPROVED' BY DEPT. DATE DRAWN K. BUN CHECKED ENGINEER CHECKED ^ DATE 8 - 8 - 9 TITLE BTDLE 0 HVAC - PLAN BUILDING 9-96 TENANT IMPROVEMENT # P1111 nIKir o_OA 0 r id 2 0 LEGEND: WALL OR DUCT MOUNTED GRILLE OR REGISTER VOLUME DAMPER ZONE & BYPASS DAMPER; NW SYSTEM L VD i 2400 DN O CEIUNG DIFFUSER, ARROW INDICATE AIR THROW GENERAL N 1. D -1 = 11TU D -2 = 11TU RAG -1 = 11TU CURRENT REVISION J #715225 -00 SHEEP JOB NO DUCT, SINGLE UNE DUCT LINER; SOUND CONTROL THERMOSTAT; PNEUMATIC AIR CELL CONNECTION WALL MOUNTED THERMOSTAT ABANDON IN PLACE CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING DUCTWORK IS NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MIXING BOXES ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. 1� BRACE EQUIPMENT PER ( 1 2M10 M521 NEW DIFFUSER AND RUNOUT DUCTWORK. 3� CAP EXISTING DUCTWORK. BRACE PER OR r OR 2M10 M521 2M10 M521 OR 2M10 M521 2M 10 4-"LAY-IN OR EQUAL 1" SLOT, 36" L X24" LAY -IN OR EQUAL NEW STRUCTURAL X -BRACE IN THIS LOCATION_ REROUTE EXISTING DUCTWORK PER 2M101M522 2M101M522 RELOCATE EXISTING DIFFUSER OR MIXING BOX TO THIS LOCATION. INSTALL NEW DUCTWORK AS REQUIRED. (ORIGINATED FROM ® ON REINSTALL EXIST. LAY -IN GRILLE & SOUND BOOT DUCTWORK. SYMBOL KEY PLAN 0 SCAM: NONE N DATE 08.10.01 COMP NO. SYM A INSTALL VAV BOXES BUILDING 9 -96 T.I. #4 ws • O "8"0 D- 345 CF (2 TYP) RAG- 8 "0 5- 345 CF (2 TYP) •I 8 "0 D- 345 CFM (2 TYP 12/12 mrififf-Ei RIR © 80 D -1 320 CFM N A , 8 "0 D- 345 CFM (2 TYP 8 "0 D 1 11 375 FM la - N � N - ® a" '05 -1 `I ° 75 CFM muniumn. Y Y 1 ii T� N U ) e ! 0-6\ \ 8 "0 D -1 \ w � ' I1D 375 CFM • c di RG -1 10' "0 RAG -1 10 "0 8 0 0-1 1 375 CFM 10"0 rm_ N ® ' __, -• � __ - - -- Lim 11 0 .. N V � ( V Y 8 "0 D -1 2 8 0 5 -1 375 CFM T 230 CFM (3 TYP) iafr 8'0 D -1 8 "0 D -1 320 FM S •'G -1 27 1 CFM g 1 1111 - `ate© e 8 "0 D -1 320 CFM 8 "0 D -1 320 CFM PAN- 10 "0 8 "0 D -1 270 CFM RAG -1 3 \ I 1 ! z RAG -1 /I 270 CFM i e \. / 8 "0 5 -1 8 "0 D -1 ° Eimi 00 D -1 40) CFM RAG - CV 8 "0 D -1 2/0 CFM VI OD 8 "0 D-1 271 FM OD 60 60 WZS] d 80 80 TRAINING RM - 60 60 60 60 ' A g K,zu MEETING r d KY5J] t 15 'ING LIJI 0 8 "0 80 D1 20CFM u I� .t it riutaii, .. r I 1l0 "0 20 CFM 80 D 100 1 270 CFM .41 _ 10 0 - -s ._5e © 10 0 li 80D -1 3 6 CFM I - fr 1u1® ( TYP) ETif' � 1 1 E , 10, �% •� 10 /1r �= - -� _ . , _ 0. 5 OF5t / RAG -1i , I I 80 D -1 2 CF 400 "0 / 1 4 7 Q I A e fa ,v ll RAG - U � ) " 0 D 1 4 \ 410 CF f I �\ .. i \\ \ \\ 375 FM ■110 "0 RAG -1 \ 8 "0 D -1 \\ 375 CFM \, 10'0 8 "0 D -1 320 u 10 1 4 1 -1 © 375 CFM CAP HOLE 8 0 320 CFM -' CAP HOLE 80 0 -1 375 CFM 8 "0 D -1 366 CFM (3) tO 401 A r 1? y 7 0 CF l r 3 A ® 8" 366 D - CFM 8 (3 TYP) � ..0 h 11 A i 1, 447, CAP HOLE 75 D -1 RAG -1 RAG -1 10 °0 10 "0 10"0 8 32C ° . ■O®= o J, -1 CFM l ®� RAG-1 8 ° 0 D-1 ; a ; IOWA= 366 CFM o e I � (3 P)10WDI_I tii 1 II i REVISION BLDG 9 -96 STRUCTURAL UPGRADE J#701888 - 00 J #703445 -05 J #715225 -00 BY DMV DLR GROUP DLR GROUP APPROVED RP RP DATE 07.25.00 03.08.01 05.10.01 SYM REVISION 0 FLOOR PLAN SCALE: 1/8 " =1' -0" BY APPROVED DATE si /NG ACCEPTABILITY THIS DESIGN .AND /OR SPECIFICATION IS APPROVED PROVED BY DEPT., DATE DRAWN K. 8110 T711-CK o ENOINLE CHECKED 0 0 DATE 8 -8 -96 SUBTITLE TITLE LEGEND: 11 2 DUCT, SINGLE LINE 0 O CEILING DIFFUSER, ARROW INDICATE AIR THROW i WALL OR DUCT MOUNTED GRILLE OR REGISTER L 1 . VOLUME DAMPER DUCT LINER; SOUND CONTROL Q THERMOSTAT; PNEUMATIC 4 WALL MOUNTED THERMOSTAT ▪ AIR CELL CONNECTION • POINT OF CONNECTION FS i i FIRE SMOKE DAMPER ES: MS, 24 "524" - 30,'(4) 1" GENERAL N'i 1. D -1 = TITUS D -2 = TITUS RAG -1 = TITUS PA HVAC -'PLAN BUILDING 9 -96 TENANT IMPROVEMENT #4 Rllli min 4 -4R 2 Y -IN OR EQUAL SLOT, 36" L 24" LAY -IN OR EQUAL CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING DUCTWORK IS NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MIXING BOXES ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. I BRACE EQUIPMENT PER 2M11 M521 0 NEW DIFFUSER AND RUNOUT DUCTWORK. . BRACE PER 2M11 CAP EXISTING DUCTWORK. OR M521 2M11 LJ/ NEW STRUCTURAL X -BRACE IN THIS LOCATION. REROUTE EXISTING DUCTWORK. © NEW THERMOSTAT . NEW RETURN AIR GRILLE EXTEND TAP TO REROUTED DUCT. ® OR 2M11 M521 2M11 CURRENT REVISION 4715225 -00 SHEET JOB NO. 2M11 OR M521 2M11IM521 M521 SYMBOL 2M10 2M12 2813 2M14 2815 COMP'NO DATE 08.10.01 27 32 KEY PLAN Sr�E r� SY A BLDG 9 -96 STRUCTURAL UPGRADE J #715225 -00 BUILDING 9 -96 T.I. #3 BUILDING 9 -96 T.L 14 RAG_ .RAG- : II , CFM r m 10`0 D 1, \ CFM FS 171 C�1 100 CD 1 2/4 6"9I 170 CFM -S ® r- 1 8P, : 8 33 "0 0 0 - CFM 1 10 "4 100 CD SIN 1 • DO STAIR r F — JI_ CFM 1 riMg -T REG _L 750 CFM nab�NI'c 24x1 REGT 24/7 8 c3 "4 c� 1 M �,� U�N L-U 270 O OH o-r. rc % k 3s /1s w� f 0 0 0"0 � 320 CFM 10 "4 0 "0 10 10 "0 4D -1 320 CFM CAP i X11 8 6 "4 D -1 187 CFM (2 WY 10 / RAG 8 "4 -0 -1 270 CFM 10 "0 !! h� ®t ; � N T e 366 CFM ET1 '11 8 "4 D -1 21 10 1d � ,.w_ sl N U Cr. P to 1 4 10 1 1 10 "4 R �I I l � O REVISION O O O J #715225 -00 J #715225 -00 DLR GROUP DLR GROUP DLR GROUP APPROVED RP RP RP DATE 03.08.01 07.27.01 08.10.01 SY REVISIO FLOOR PLAN SCALE: 1/8 " =1' -0" APPROVED DATE 0 -i IV Itii NI W A&A ` fil ! 1 "4 D 1 El. , f QA 11 1 8 4 p ,1Q 11 370 CFM 1 I T 0 � RAG -1 320 tali RAG - 1� � � 1 10 "4 i � 8 "4 D 1 10 8 °8' 4 rill `L � �1�1 275 C y� 4 it 1 , ; 0 i k 1 i OF �E r r 1 187 1 L D 4 ei n ?� _ 6 4 it 2 iF l 1 , F i , � CFM =1 ` c2 rap) mum. © / re;LAramstrAw I I � OPEN I ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE DRAwN K. BUN CHECKED - ENGINEER CHECKED 8 - 8 - 96 BTDLE 17 HVAC — PLAN TITLE BUILDING 9-96 TENANT IMPROVEMENT, #4 P1 iii nim Q OP 9 4. D-1 = TITUS D -2 = THUS RAG —1 = 11TU LEGEND: 1 2 DUCT, SINGLE LINE O CEILING DIFFUSER, ARROW INDICATE AIR THROW 2 wD t 0 4 FS GENERAL NOTES: D. ABANDON IN PLACE WALL OR DUCT MOUNTED GRILLE OR REGISTER VOLUME DAMPER DUCT LINER; SOUND CONTROL THERMOSTAT; ELECTRIC AIR CELL CONNECTION POINT OF CONNECTION FIRE SMOKE DAMPER 1. SHEET METAL DUCT IS TO BE INSULATED WITH 1 1/2 BLANKET_ 2. MANBARS PER 83— BMAC -1. 3. AIR TRANSFER BOX PER 84— BMAC -7 YIN OR EQUAL SLOTS, 361L 24" LAY —IN OR EQUAL CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING DUCTWORK IS NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MIXING BOXES ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. BRACE EQUIPMENT PER 2M12 M521 2� NEW DIFFUSER AND RUNOUT DUCTWORK_ CAP EXIST. DUCTWORK. . BRACE FOR UPPING HAZARD. NEW STRUCTURAL X -BRACE IN THIS LOCATION. REROUTE EXISTING DUCTWORK PER NEW RETURN AIR GRILLE. NEW THERMOSTAT. — EXTEND DUCTWORK TO NEW MIXING BOX LOCATION. amENT REVISION J #715225 -00 SHEET 2M12 SYMBOL 2M12 M522 2M121M522 DATE COMP N0. 08.10.01 P -5 JII tP S (4 TY `;P 6 P); r- P -31 LS P -3 I P-2 P-2I P -1 L> P -3 P 1 vi $" , / P -1 MEN'` P -4I 101E05 P -2 MEETNG C MEETING L n \ ? 1 F mEc,H. 10iFG I PLAN 1/8" - 1' -0" rt MEETING OPEN OFFICE 1 101,103 I 102L01 APPROVED 0 LC; du1LU11V'l7' 27 =yn LEGEND: EXISTING FIRE PROTECTION SPRINKLER BEAD GENERAL NOTES: 1. SEE SHEET M523 FOR PLUMBING SCHEDULE. CONSTRUCTION NOTES: JOB NO. 1M261 12 1M262 I 17 PE �:�4�"`� 1M263 @,01 ti 1M264 ! 09 � 27 1M265 32 4 I I I SYM REVISION BUILDING 9 -96 T.I. #4 #715225 -00 DLR GROUP APPROVED RP DATE 08.10.01 SYM REVISION BY APPROVED DATE ?LiezrAseAw. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DATE DEPT: DRAWN K. PAULSON CHECKED ENGINEER HECKED DATE 02.28.01 1ST FLOOR FIRE PROTECTION PLAN BUILDING 9 -96 TENANT IMPROVEMENT #4 CURRENT REVISION J #715225 -00 SYMBOL A SHEET 1M 11 0 DATE COMP NO. 08.10.01 SYM A UILDING 9 -96 T.I. #4 OFFICE �i. 1 1 11 A09 1 1 1 REVISION C1 O9; 10 4715225 -00 BY DLR GROUP APPROVED RP DATE 08.10.01 SYM EXISTING 2'' CW MEETING L101007 REVISION II ( : 1A1110452 OFF- RM 1101C )7 APPROVED DATE Ci 01 J0 i : i MEETING 1 101009 OFFICE 101011 cA__Ansrk=zAhg. MEETING 101907 OF FICE UhI` OPEN - FIB 10 1 102009) PTO 2 , 1 t 1 00 100 OFFICE 1101 902 1 11o2J09 OFF ICE , 10%1111 �' 1 112, 1 \ `101 K1(102K.'K': ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. OFFICE 1102M091 DATE CHECKED NNOIAEER CHECKED DATE UBNTLE 01 1ST FLOOR PARTIAL', PLUMBING PLAN nn_E BUILDING 9 -96 TENANT IMPROVEMENT #4 P1 111 min a-QA 1 CONSTRUCTION NOTES: D- NEW 1/2" CW LINE TO COFFEE MAKER. JOB NO: CURRENT REVISION J #71 5225 -00 SYMBOL SHEEP 1 111 H �V1v 2.1 100 ?8 099988 08 DAT COMP N0: 08.10.01 S A BUILDING 9 -96 T.I. #3 BUILDING 9 -96 T.I. #4 REVISION 0 J #715225 -00 J #715225 -00 DLR GROUP DLR GROUP MFFTIN(= EXISTING 4" CW O'FE RM 1 -1/2 EX. 1/2 gvy STAIR F 1 -1 4 V ©I 1 2 "W 2" W CORRIDOR -EX. 2° V UP CLOSE( II \ p LX,2 ° 1-1/4° 1/2 CW V UP EX. 3" FCO CORRIDO EWC -1 1 1/2" TO E CONT EX. 1/2 CW MEETING MEETING APPROVED RP RP DATE 1FRCCE 07.27.01 08.10.01 SYM REVISION MEETING FLOOR PLAN SCALE: 1/8 " =1' -0" APPROVED DATE p rizsrivv. MEETING "PEN OFFICE it EN OFFi;E ACCEPTABILITY THIS DESIGN AND /0R SPECIFICATION 15 APPROVED DEPT. DATE DRAWN CHECKED ENGINEER CHECKED APPROVED M0 1 -141 TE SUBTITLE 17 PLUMBING - PLAN BUILDING 9 -96 TENANT IMPROVEMENT #4 BUILDING 9 -96.1 LEGEND GENERAL NOTES 1. EWC -1 = ELKAY ERHP2 -8 WITH PLUG CORD. REFERENCE DRAWINGS CONSTRUCTION NOTES i� EXTEND NEW CW UNE TO EX. 1/2 CW TO SERVE EWC -1. ' NEW 1/2" CW LINE TO COFFEE MAKER CURRENT REVISION J #715225 -00 SHEET 1M 112 JOB N SYMBOL cnnG nn KEY SCALE NONE LAN DATE 08510.01 COMP NO A EDRAWN LDG 9 -96 STRUCTURAL UPGRADE UILDING 9 -96 T.I. #1 REVISION J #703445 -05 J #715225 -00 BY KB DIP GROUP DUB GROUP APPROVED RP RP DATE 03.08.01 06.29.01 SYM UILDING 9 - 96 T.I. #4 REVISION J #71522 -00 BY DLR GROUP APPROVED RP DATE 08.10.01 ACCEPTABILITY K BU THIS DESIGN AND /OR C SPECIFICATION IS APPROVED R. SQUIRES APPROVED BY DEPT: DATE CHECKED APPROVED. DATE 8 -8 -96 8 -8 -96 UBTITLE PLUMBING - PLAN BUILDING 9 -96 TENANT IMPROVEMENT #4 BUILDING 9 -96.1 GENERAL NOTES: 1. SEE SHEET M523 FOR PLUMBING SCHEDULE. LEGEND: CONSTRUCTION NOTES: NEW 1/2" CW ONE TO COFFEE MAKER. CURRENT REVISION J #7 15225 - 00 SHEET SYMBOL 1M 114 ATE 08.10.01 OMP NO. I ,I 23 z II it MEETING it MEETING r 101J23 1 I. 1101K23I �_ i CU.K23 _ I 1=_NvFflCE j l I I'� , _ 4I01J23 is s >, I r. / 1/2" CW TO COFFEE MAK R COFFEE RA I ;O , f y I'102J2ti L.14. i ME I 2 , '% 110 F23 I ' ( 01J2L) MEETING IlO1J24j -4 -_ ?_ - ,, EXTEND 1 -1/4 W UP TO SECOND FLOOR F1' } ,''11" _ P -10. (� : CONNE T EWC TO EX. ..._ -._ � r� L 1 & V-LINES. N � • .. ,. \z ,..=„_ ...�. /SAW �� 1 ____ . ci I 1 ;j I �a 1/2 1 OW TO ME EXISTING ■ Ir'' I 1 -1/4" COF .E MAKER W & V IN 431 . WALL. 0 L am-- EXIST. 4" CW F \ A EDRAWN LDG 9 -96 STRUCTURAL UPGRADE UILDING 9 -96 T.I. #1 REVISION J #703445 -05 J #715225 -00 BY KB DIP GROUP DUB GROUP APPROVED RP RP DATE 03.08.01 06.29.01 SYM UILDING 9 - 96 T.I. #4 REVISION J #71522 -00 BY DLR GROUP APPROVED RP DATE 08.10.01 ACCEPTABILITY K BU THIS DESIGN AND /OR C SPECIFICATION IS APPROVED R. SQUIRES APPROVED BY DEPT: DATE CHECKED APPROVED. DATE 8 -8 -96 8 -8 -96 UBTITLE PLUMBING - PLAN BUILDING 9 -96 TENANT IMPROVEMENT #4 BUILDING 9 -96.1 GENERAL NOTES: 1. SEE SHEET M523 FOR PLUMBING SCHEDULE. LEGEND: CONSTRUCTION NOTES: NEW 1/2" CW ONE TO COFFEE MAKER. CURRENT REVISION J #7 15225 - 00 SHEET SYMBOL 1M 114 ATE 08.10.01 OMP NO. SY A B REDRAWN REVISION BLDG 9 -96 STRUCTURAL UPGRADE BUILDING 9 -96 T.I- #1 BUILDING 9 -96 TI# 2 O D J #703445 -05 J #715225 -00 J #715225 -00 BY KB DLR GROUP DLR GROUP DLR GROUP APPROVED RP RP RP DATE 03.08.01 06.29.01 07.13.01 SYM THIS AREA'S LAYOUT IS NOT SHOWN CORRECTLY. SEE 2/1A453 FOR CORRECT LAYOUT. P -* CALLOUTS ARE SHOWN IN APROXIMATE ONS. EZUEI P -7 WOMEN'S D r DATA 1101 628 EETIN !!1QiC2 =1 REVISION it MEET !Lo O O P APPROVED DATE LOADING 1 101630 1 1 1'�h STORAGE 1101H29 O - 1 4 1 LEGEND: GENERAL NOTES: CONSTRUCTION NOTES: CAP EXIST. CW, W, & V. (11 #1 HAD NEW EWC -1 AT THIS LOCATION_ THIS HAS BEEN CHANGED. SEE 1M114 FOR REVISED LOCATION.) 11,oV 2 2. i�Ul vo w cenlf" e 1Z /NG° ACCEPTABILITY THIS DESIGN AND /0R SPECIFICATION IS. APPROVED APPROVED By DEPT. DATE DRAWN K. BUN CH CKED R. SQUIRES LAIGINLEN CHECKED PPROVED DATE 8 -8 -96 8 -8 -96 SUBTITLE PLUMBING - PLAN nn-E BUILDING 9 -96 TENANT IMPROVEMENT #4 BUILDING 9 -96.1 CURRENT REVISION SYMBOL J#715225-00I SHEET SHEET 1 j ND. ,1471 5975 -nn DATE COMP NO. 08.10.01 BUILDING 9 -96 T.I. #4 REVISION J #715225 -00 C DLR GROUP APPROVED RP DATE 08.10.01 P _ 5 'GIviE^ 41YP fc I0f . /5' P -3 [Ls 1 P -3 \ el P -2 THIS AREA NOT SHOWNF� P -1c it---) P -1 CORRECTLY. SEE I P -4 ' 4/1A454 FOR CORRECT 1 i i O p-1 'P 1 LAYOUT F-1 [di P -6 STAIR J OFFICE MEETING OFFICE OPEN" OFFIy it SUM 0 MECH PENSION _s'O RM 'TRAINING FGr APPROVED DATE rt Z APPROVED BY 4—. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION; IS APPROVED DEPT. DATE 0 0 DRAWN K: PAULSON CHECKED CHECKED GENERAL NOTES: 1. SEE M523 FOR PLUMBING SCHEDULE. DATE' 02.28.01 SUBDTLE 2ND FLOOR PLUMBING PLAN BUILDING 9-96 TENANT IMPROVEMENT #4 RIIII h1N(, 9 -9 9 LEGEND: CONSTRUCTION !NOTES: CURRENT REVISION SYMBOL J #71 5225 00 SHEET' 2M 110 JOB NO 2M262 DATE COMP NO 17 08.10.01 YM A BUILDING 9 -96 T.I. #4 REVISION 1/2" CW TO COFFEE MAKER 1 /2" CW TO COFFEE M KER 01J08) MEETING 1! MEETING r201 J08 11 ;20108 OFFICE 201A11 J #715225 -00 BY DLR GROUP c1FEi: C=FICE .:7 OFFICE OFFICE 1201p11 202C11 I MEETING APPROVED RP DATE 8.10.01 I F 'I i ;I MEETING 201D08 I SYM REASON EXISTING 2" CW IN 1ST FL. CEILING APPROVED RAINING 00 [ O1F02J MEETING I201F10� O i'Lawrerlsva. OPEN OFFICE 1201J09 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION 15 APPROVED APPROVED BY DEPT. DATE DRAWN CHECKED ENGINEER CHECKED APPROVED ATE SUBTITLE 2ND FLOOR PARTIAL PLUMBING PLAN BUILDING 9-96 TENANT "IMPROVEMENT' #4 BUILDING 9 -96.2 CONSTRUCTION NOTES: NEW 1/2" CW UNE TO COFFEE MAKER. CURRENT REVISION J #71 5225 -00 SYMBOL SHEET 2M111 JOB N0. 71Roo, /In DATEI 08.10.01 COMP NO. A UILDING 9 -96 T.I. #2 UILDING 9 -96 T.L #3 UILDING 9 -96 T.I. #4 0 CD REVISION 1/2" CW T J #715225 -00 4715225 -00 J #715225 -00 BY DLR GROUP DLR GROUP DLR GROUP COFFEE MAKER APPROVED RP RP RP <201D25 CONNECT TO 1 -1/4" W EXTENDED UP FROM 1ST FLOOR. CONNECT EWC TO EX. CW & . , LINES. 2011'25 I IOI? DATE 07.13.01 07.27.01 08.10.01 4" EXISTING CW SYM REVISION 1 BY APPROVED DATE ? OPEN OFFICE 1 201,114 1 ACCEPTABILITY THIS DESIGN. AND /OR SPECIFICATION IS APPROVED, . DEPT. DATE DRAWN DLR GROUP cE I - CHECKED APPROVED Fd A TE 07.13.01 UBTITLE PLUMBING - PLAN T1i BUILDING 9-96 TENANT IMPROVEMENT #4 BUILDING 9 -96.2 n LEGEND: CONSTRUCTION NOTES: NEW 1/2" CW LINE TO COFFEE MAKER CURRENT REVISION J #715225 -00 SHEET JOB NO SYMBOL 2M114 .13317.1 5995 -M DATE COMP NO. 08.10.01 SYM A BUILDING 9 -96 T.I. #2 REVISION J #715225 -00 DLR GROUP APPROVED RP DATE 08.10.01 SYM REVISION E)( ) SCALE: 1/8 "= 1' -0 APPROVED PLUMBING PLAN DATE e lr�.) ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN DLR - 9. PAULSON CHECKED 'N- CHECKED APPROVED Ate, 08.09.01 BRRE 2ND FLOOR PLUMBING PLAN BUILDING 9-96 TENANT IMPROVEMENT #4 BUILDING 9 -96.2 LEGEND Effl GENERAL NOTES CONSTRUCTION NOTES KEY PLAN SCALE:. NONE CURRENT REVISION J #715225 -00 SHEET JOB NC). 12171 2M260 /j 2M261 2M262 2M263 2M264 r�� of %2M 5 ��� 21 � 0 /iii /// 32) e "` SYMBOL 2M 115 COMP N0. 08.10.01 SYM A REVISION BLDG 9 -96 STRUCTURAL UPGRADE BUILDING 9 -96 T.I. # J# 703445 -05 J #710225 -00 BY BUS GROUP OUR GROUP APPROVED RP RP DATE 03.08.01 08.10.01 SY RENSION BY APPROVED DATE zi_Arame-Ariv.w. (Ee ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT: DATE (N� DRAWN' K. PAULSON CHECKED €N FIER CHECKED DATE 02.28.01 01 -141 BTTRE LB A 1ST FLOOR FIRE PROTECTION PLAN TIDE BUILDING 9 -96 TENANT IMPROVEMENT #4 171 III 111A1^ !1 nn ._. LEGEND: • EXISTING FIRE PROTECTION SPRINKLER HEAD GENERAL NOTES: CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING FP MAINS ARE NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MAINS ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. NEW LINK CONSTRUCTION REQUIRES NEW FIRE PROTECTION SYSTEM LAYOUT. BRACE PER CURRENT REVISION J #715225 -00 1M2601M521 1M2601M521 FIRE PROTECTION MAIN SIZES WERE NOT PROVIDED IN THIS AREA. CONTRACTOR TO CONFIRM MAIN SIZES. SPRINKLER HEAD DROP INTERFERES WITH NEW LIGHT LI '01. :E I TE DROP. THIS AREA'S LAYOUT HAS CHANGED. PLEASE CONFIRM COVERAGE. © RELOCATE SPRI ' ER AINS & BRANCHES INTERFERING WITH NEW STRUCTURAL X- BRACING INSTALLATION & LOCATION. HELD COORDINATE. i e 1M260/ 1M262 1M263 I 1M264' 1M265 KEY PLAN SYMBOL SHEET 1 M521 1M2601M521 DATE 08.10.01 \ Y Y v O ' T: c > �. T s . — IN - :- — — — T ` -D J , r 1 ' '1 I 1 I- I 4 j ! 2 L , ;FIE I I • II __ r I ; I h I I i J INj ME TI. , ° 111111111b }/ 1 K I 1 1= 11 ILJ .h •-N I t 2JG 1 A j j • ? • j • 1 t 1Gj �t� - • •! I I ' 1�� I' ( I• ' / 1 • I Le 11 • _ - ) I \ \ 1 I' I + ! b I `' } I \ r J 11111.1 ! I � J I PI l ` ON MAINS 2 -1/2" & LARGER , _ax.- " ' 1 ' O - _#'�'" — .. ;I 4- t , \ . - - _– { – 5 - I _ . i-- - - •- ' a�I - - . 1 I • I • j I LJ e[ ! I 1 �� .I �. I � ! f ' �I � I I - i �L__ IL _J N1 � i I I Li I i I L' I \ 11 �: 1 _ j - T I L —, f J - I ll. ' _.-� - ! I ! . (7 1 I I� II LII I I ! • � 1 ' ilt r�l � a .. � Q I � J Ur te , , 5 11 111311 1111 t IP' I �1 r 1 :i • I H I` I I 9 I ` r 1 �� 1111_1111 ® I 1 E F I I I I 1 I I �I I. _ •1 j .. i■ • ► �I �. o '. In 1111 r III _111 ' r I I I , ..........c. ' . �, q . O i ii - -- • 1 rl [ I ( ' i ' I I (' S OOIYL STO 0-1J 1 J _ LJ I G ' j 1 I / I ' 1 1 �. — I I i t I 1. I ; I �....�....���a��., 1 ; III Ilr • 11111 I I I \ II I ! 10 JO I • I I ' I I I r I 1_ i P 1 10105 1 .j r I I I T . -i_e..v , i �� - i. -l-1m I II 1 1 1, I j� �. T- '., �\ 1 I • 1 �JI !f.l'] 1I 1 i� • ( I j ; - ..01 •i ' ' I 1 l E I :! L._ "r� 1" fr ` T,k• , 3 I ' i - T 'j. I II , ; . I - -�,� -' L 9 ' � .- �1 - L -1 1 l I i d i ll 1 : i / � � If _� � �' . !" li. rt Ir , , F - 1 \, II I • I 1 INI 1 I II - - - I ! I 1 I I I u i j O , _ . I I t 1 � . H L_ T : 1 \ I 1 i r I I I i I L � � I I I 1 _ __. 1 L -I b _ �., it am .,.. - 1 ...A. I `,1 I I 1 I_ I I i , , I �1 ' I I A 'I I U 11 I I , I i At. 1 1 ..® n�' i .. . \ �, J I ,,, 1 j �• .. ® ,TO +7-1 M EI � I, 1 •, i ' i 1 I I I �1 =�r1 (�6 r 1 I I: i � — - - _ X11 1 J , V +--_I - - , — _. \ r Fir , �` J SYM A REVISION BLDG 9 -96 STRUCTURAL UPGRADE BUILDING 9 -96 T.I. # J# 703445 -05 J #710225 -00 BY BUS GROUP OUR GROUP APPROVED RP RP DATE 03.08.01 08.10.01 SY RENSION BY APPROVED DATE zi_Arame-Ariv.w. (Ee ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT: DATE (N� DRAWN' K. PAULSON CHECKED €N FIER CHECKED DATE 02.28.01 01 -141 BTTRE LB A 1ST FLOOR FIRE PROTECTION PLAN TIDE BUILDING 9 -96 TENANT IMPROVEMENT #4 171 III 111A1^ !1 nn ._. LEGEND: • EXISTING FIRE PROTECTION SPRINKLER HEAD GENERAL NOTES: CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING FP MAINS ARE NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MAINS ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. NEW LINK CONSTRUCTION REQUIRES NEW FIRE PROTECTION SYSTEM LAYOUT. BRACE PER CURRENT REVISION J #715225 -00 1M2601M521 1M2601M521 FIRE PROTECTION MAIN SIZES WERE NOT PROVIDED IN THIS AREA. CONTRACTOR TO CONFIRM MAIN SIZES. SPRINKLER HEAD DROP INTERFERES WITH NEW LIGHT LI '01. :E I TE DROP. THIS AREA'S LAYOUT HAS CHANGED. PLEASE CONFIRM COVERAGE. © RELOCATE SPRI ' ER AINS & BRANCHES INTERFERING WITH NEW STRUCTURAL X- BRACING INSTALLATION & LOCATION. HELD COORDINATE. i e 1M260/ 1M262 1M263 I 1M264' 1M265 KEY PLAN SYMBOL SHEET 1 M521 1M2601M521 DATE 08.10.01 SYM BUILDING 9 -96 T.I. BLDG 9 -96 STRUCTURAL UPGRADE BUILDING 9 -96 T.I. #3 O O REVISION J #703445 -05 J #703445 -05 4715225 -00 BY DLR DLR GROUP DLR GROUP O O O 0 O ® ® O APPROVED RP RP RP DATE 02.23.01 03.08.01 07.27.01 SYM REVISION BY APPROVED DATE PLAN. 1/8" = 1 -0 gLararisisva. ACCEPTABILITY THIS DESIGN AND /0R SPECIP1CATION IS APPROVED APPROVED BY DEPT. DATE DRAWN H.CHURCH CZKED, ENGIN1 . CHECKED APPROVED O O DATE 01 -22 -01 ON MAINS 2 -1/2 Sc LARGER ON MAINS 2 -1/2 & LARGER SUBTITLE 12 MO1 -141 1ST FLOOR FIRE PROTECTION PLAN T : BUILDING 9 -96 TENANT IMPROVEMENT #4 BUILDING 9 -96.1 LEGEND: —r— GENERAL NOTES: CONSTRUCTION NOTES: SPRINKLER HEAD , P001DENT IN LINE SPRINKLER HEAD, UPRIGHT AUTOMATIC SPRINKLER RISER HALON SYSTEM AUTOMATIC DISCHARGE STATION SPRINKLER HEAD, SIDEWALL, UPRIGHT 1. THIS'. AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS —BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING FP MAINS ARE NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MAINS ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. THIS AREA'S LAYOUT HAS CHANGED_ PLEASE CONFIRM COVERAGE. BRACE PER 1M26 OR 1M261 M521 � M521 1M261 M521 1M261 M521 FIRE PROTECTION' MAIN SIZES WERE NOT PROVIDED IN THIS AREA. CONTRACTOR TO CONFIRM MAIN SIZES. — SPRINKLER HEAD DROP INTERFERES WITH NEW LIGHT LOCATION. RELOCATE DROP. SPRINKLER HEAD DROP INTERFERES WITH NEW CEILING COFFER. RELOCATE DROP_ © NOT USED. RELOCATE SPRINKLER MAINS & BRANCHES INTERFERING WITH NEW STRUCTURAL X— BRACING INSTALLATION & LOCATION. FIELD COORDINATE. CURRENT REVISION J #71 5225 -00 SHEET' SYMBOL D 1M261 JOB N0. cnn� nn DATE COMP N0. 08.10.01 O O O (H� f` RI Da Q -4R CTRI I!`.TI IRAI I IP(:RADF .47f 44 -n, DI R f:Rnip RP fl (1R.01 PLAN 1/8 1 ,_0., CHECKED LB MO1 -141 8 2M260 M521 2M26011_,,4521 O O LEGEND: . FIRE PROTECTION SPRINKLER HEAD GENERAL NOTES: CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING FP MAINS ARE NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MAINS ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. . NEW LINK CONSTRUCTION REQUIRES NEW FIRE PROTECTION SYSTEM LAYOUT. BRACE PER 2M260 M521 2M260 d 521 FIRE PROTECTION MAIN SIZES WERE NOT PROVIDED IN THIS AREA. CONTRACTOR TO CONFIRM MAIN SIZES. . SPRINKLER HEAD DROP INTERFERES WITH NEW LIGHT LOCATION. RELOCATE DROP. THIS AREA'S LAYOUT HAS CHANGED. PLEASE CONFIRM COVERAGE. SPRINKLER HEAD DROP INTERFERES WITH NEW 0 S" I LE AIRS & BRANCHES INTERFERING WITH NEW STRUCTURAL X- BRACING INSTALLATION & LOCATION. FIELD COORDINATE. O OM60O 2M261 I 2M262 � 17 2M263 2M264 67 gt�MN` 2M265 0 F . 0 1..P 4 ` — 32 : 0 : OoW0 KEY PLAN DATE TOM A REVISION EXTEND CEILING TO VOID B2 CONSOLIDATION J #157117 -00 BY DAB II MRM APPROVED DATE 8 -26 -97 SYM REVISION BY APPROVED DATE a_AraorEzow ACCEPTABILITY THIS DESIGN AND /OR.. SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. PAULSON CHECKED ENGINEER PA R 28.01 SUBTITLE 2ND FLOOR FIRE PROTECTION PLAN. TITLE. BUILDING 9 -96 TENANT IMPROVEMENT #4 CURRENT, REVISION J #715225. -00 SYMBOL D SHEEP 2M 6 08.10.01 12 22 I I O I I I I I 1 o I I I I ' � I, i I :, i' ICE ! ! i I 1 f OF ICI � 'I II I ��� �t� � � � IC E, I • , j r �I 0 FIC.E • , � Lr IC :grit. '' � O�� I ,1 ' �i1FFlc' • ' 'I r11F 'IC 1 3 • � I N ' : " I { 4 IRFh I • - rF FI�E �I i �� 1 i F ), F CE F I ' { • 0 FIIE I MAINS 2 & LARGE ON AI S 1/2" R 3 __J . L IL { AI I_—I • , ITS . O: . i I � 4 , It • _ , l Ti • i .�1 ► I ilIpiJ L I L� I • I 'I III J I ! I�I • � slim I _ / s l.i II i� '1 iii i Iiiiuii fl I f j 1?1I I II • I ' ' • I I I li 4 i O — l j • i:� 4 L • ;ice ( i O ,W -t . ..... 6. ..I�nee.. eI11I1�11i11111 ��i o I I � I I I i i I I i I 1 I ! .tl 1111111!11111 _ U II ;I I �I I I� i 11 • III II I ' � dill LA • 4 S ` � 'dI IIPi O CUSTQDI � i .�_ ill iii 111111 ' 11,1 T ; I r I ! -1 I t L O i • ', '_ L I i'l • 0 f � � 1111 - L-J f 1 I I ' � I r - ii Aril . P +i`! � FFI . ow2rd/d// p , ' (� — )UJ rr I - I�'Gc / / ddmd//. r1 d. W ORN• i $ 1 J - , • -r ' I • I ', r •, A. L I IP ,, iii t om • 0 --' �� �II • I l I � r III �� j • . ' • • F 4 1 s rI.. S � 'G ; � 0 J Q ) I r ::__ I I I 1 t - — kF I In I i �J I ' O I i j; ; I • I - NI I u I I j L— , �I! 1 4 t�1 j � / • i ' I I II'_•I II I CI L� !li; I Li • ;I 'r Do s 31 I '�® "� I I j I ` � •' O ©��, ; . 'T ����.�...i..c.� • I •i . 1 • f ( /.I 1 I if I e i j °_ . JI �� J j-1 ire u I El I j I O I • �� u ' t 1 r J g ' M E1'NG — �� I j -- { MI. I I I I - Pr gg I ,,I // /- 1 , 9 / 1 /� ®YdYd / /d / / ® I II I I II , a #:_,,,,, �.,.aaaa�. J I I IL 1 I • W i III I-I I I . . I � I . I I HO_ I i I I I -- t • I 1 r I I r ® - - - ice - � � T T - 7 O _ Mr 1 O O O (H� f` RI Da Q -4R CTRI I!`.TI IRAI I IP(:RADF .47f 44 -n, DI R f:Rnip RP fl (1R.01 PLAN 1/8 1 ,_0., CHECKED LB MO1 -141 8 2M260 M521 2M26011_,,4521 O O LEGEND: . FIRE PROTECTION SPRINKLER HEAD GENERAL NOTES: CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS -BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING FP MAINS ARE NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MAINS ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. . NEW LINK CONSTRUCTION REQUIRES NEW FIRE PROTECTION SYSTEM LAYOUT. BRACE PER 2M260 M521 2M260 d 521 FIRE PROTECTION MAIN SIZES WERE NOT PROVIDED IN THIS AREA. CONTRACTOR TO CONFIRM MAIN SIZES. . SPRINKLER HEAD DROP INTERFERES WITH NEW LIGHT LOCATION. RELOCATE DROP. THIS AREA'S LAYOUT HAS CHANGED. PLEASE CONFIRM COVERAGE. SPRINKLER HEAD DROP INTERFERES WITH NEW 0 S" I LE AIRS & BRANCHES INTERFERING WITH NEW STRUCTURAL X- BRACING INSTALLATION & LOCATION. FIELD COORDINATE. O OM60O 2M261 I 2M262 � 17 2M263 2M264 67 gt�MN` 2M265 0 F . 0 1..P 4 ` — 32 : 0 : OoW0 KEY PLAN DATE TOM A REVISION EXTEND CEILING TO VOID B2 CONSOLIDATION J #157117 -00 BY DAB II MRM APPROVED DATE 8 -26 -97 SYM REVISION BY APPROVED DATE a_AraorEzow ACCEPTABILITY THIS DESIGN AND /OR.. SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. PAULSON CHECKED ENGINEER PA R 28.01 SUBTITLE 2ND FLOOR FIRE PROTECTION PLAN. TITLE. BUILDING 9 -96 TENANT IMPROVEMENT #4 CURRENT, REVISION J #715225. -00 SYMBOL D SHEEP 2M 6 08.10.01 12 22 5 A REVISION O EXTEND CEILING DAB II BLDG 9 -96 STRUCTURAL UPGRADE DImnm, n._nc TI.A 4703445 -05 DLR GROUP n1 D l`Dni ID APPROVED RP DD DATE 03.08.01 SYM REVISION PLAN 1/8" = 1' -0' BY APPROVED DATE H OJ ACCEPTABILITY THIS DESIGN AND /OR. SPECIFICATION IS APPROVED APPROVED BY DEPT. 0 DATE K. PAULSON 02.28.01 CHECKED CHECKED O O ER 10 C MO 1 -141 SUBTRLE 2ND FLOOR FIRE PROTECTION PLAN BUILDING 9-96 TENANT IMPROVEMENT #4 LEGEND: • FIRE PROTECTION SPRINKLER HEAD GENERAL NOTES: CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING FP MAINS ARE NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MAINS ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. NOT USED. BRACE PER 2M261 M521 2M261 2M261IM521 2M2611M521 FIRE PROTECTION MAIN SIZES WERE NOT PROVIDED IN THIS AREA. CONTRACTOR TO CONFIRM MAIN SIZES. SPRINKLER HEAD DROP INTERFERES WITH NEW WALL. RELOCATE DROP. © THIS AREA'S LAYOUT HAS CHANGED. PLEASE ONFIRM COVERAGE. SPRINKLER HEAD DROP INTERFERES WITH NEW RE ' AT S & BRANCHES INTERFERING WITH NEW STRUCTURAL X- BRACING INSTALLATION & LOCATION. FIELD COORDINATE. C('('1 OP �KW11A NO 2 2 2001 mom' CURRENT. REVISION SYMBOL. J #715225 -00 SHEET' 2M261 Y - 2M260 2M262 2M263 © ' zz 2M264 27 2M265 L. . 32 KEY PLAN DATE I yl 08.10.01 I • � - . • , i ! IOW I �I C E • _ � i C ■ Mi I O I I 0 i 11 all 1 ®I I �if� II �� � liii• I � � y I L T ® 11 4, � • � 1 � I ' I ! 1 L.- ' ' i - I1 � � ,• I ! ' w ' � _ .. 1 VIII I I I! 1 I' I I I- 1� II Ili I .. I J ! • � i Iv! I iR _ G 1_ 1 II I I 1011 ► • I i . � , ! F I • • —I .....441------ ' � I I I I fill v1 I I • 4/ 1 1 � I : ,_.. � ®•I ®� ' • I i I ! I � E ! i ON MAI NS 2 -1/2 & LAR( IT I E i i ± • 1 ME!!, .' r I a1 n a . �� j • a MINIM 1110111 I I I I .. �_d i • ,!• I L ( • ma D " m 1 I I I L r • I • i i!!t I I' r -V ..� I 1 ■ 1 I f I I f �• I I i I I II I �' V• I • , ; r 1 I�_I�_ L- I �_l�_ `� 1 I ® I it I j I> 1 I II 1 i I 11 • ! I i I ij II I I' ©I Y ' I ( �( I El1 �I ! IIIiuIii . • I I I I i r i I I I l 1 I II MEET I I l_ �i I !I • , I I' • f !r I 1 � I ABM � � II I- I n I I• I I l I, I I • f ' II I - - I' N I� .J + �I i I 1 1 ! I CI ' I • -- u I - • r L� I I a • ..� • I I li !! • I ' �I n j I I - • I ®1 � ! ' I I � �I I L i �I I _ • '–' • I — I .. » _� rwc - s.. -- -I-- � I I• 1 I I II I i II `—I • iI T • -- I II I • I I I HL I - i f j• I' I I • I t I ( � I L i! J � I I ii ' r • -- --- T MA I S _ L ... 1 � i__1 Li v 1 ;• • `, Li LI I .I I _lI ! i s I �� Iil • 1 L I I ! I I �� I 4 �I i1 In '� i I I J I 1 — �- I. _ \ , I �� I ' ! I L _ OF a I! L. I E r 1 , MEF No 4 . I ; ' . L ��! ► II I ., '', 1 h.) ,i '1'1111' h • 1 7 • • � I II l• ' , 1 I I �I 1�1 1-- 1 _ I , F FEAT N I1 1 • I� . I I ! I I i i ( i 1 r 1 ! ` I i • • _ • t I t 7 I IC • I P i . T— -.• 1 5 A REVISION O EXTEND CEILING DAB II BLDG 9 -96 STRUCTURAL UPGRADE DImnm, n._nc TI.A 4703445 -05 DLR GROUP n1 D l`Dni ID APPROVED RP DD DATE 03.08.01 SYM REVISION PLAN 1/8" = 1' -0' BY APPROVED DATE H OJ ACCEPTABILITY THIS DESIGN AND /OR. SPECIFICATION IS APPROVED APPROVED BY DEPT. 0 DATE K. PAULSON 02.28.01 CHECKED CHECKED O O ER 10 C MO 1 -141 SUBTRLE 2ND FLOOR FIRE PROTECTION PLAN BUILDING 9-96 TENANT IMPROVEMENT #4 LEGEND: • FIRE PROTECTION SPRINKLER HEAD GENERAL NOTES: CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT WITH THE AS BUILT INFORMATION. UNLESS NOTED FOR BRACING, CONTRACTOR TO VERIFY EXISTING FP MAINS ARE NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MAINS ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. NOT USED. BRACE PER 2M261 M521 2M261 2M261IM521 2M2611M521 FIRE PROTECTION MAIN SIZES WERE NOT PROVIDED IN THIS AREA. CONTRACTOR TO CONFIRM MAIN SIZES. SPRINKLER HEAD DROP INTERFERES WITH NEW WALL. RELOCATE DROP. © THIS AREA'S LAYOUT HAS CHANGED. PLEASE ONFIRM COVERAGE. SPRINKLER HEAD DROP INTERFERES WITH NEW RE ' AT S & BRANCHES INTERFERING WITH NEW STRUCTURAL X- BRACING INSTALLATION & LOCATION. FIELD COORDINATE. C('('1 OP �KW11A NO 2 2 2001 mom' CURRENT. REVISION SYMBOL. J #715225 -00 SHEET' 2M261 Y - 2M260 2M262 2M263 © ' zz 2M264 27 2M265 L. . 32 KEY PLAN DATE I yl 08.10.01 C BUILDING 9-96 T.I.#4 J#715225-00 DLR GROUP RP I\ / /\ 1 11•1 I! v! II 1 J 1 - ' 1 A 1©! I 1 . 1 • ,,- , 4 ,...$) ">:' . Hsx''• '''',<1 '': 1 08.10.01 I 1 4 ! , I I I , PLAN 1/8" = 1-0" FOD MEN'S SYM A REVISION BLDG 9-96 STRUCTURAL UPGRADE J#703445-05 80 DLR GROUP B BUILDING 9-96 T.I. #3 4/715225-00 DLR GROUP APPROVED RP RP DATE 03.08.01 07.27.01 SYM REVISION BY APPROVED DATE c(Y ZLaraw,,E 'ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DRAWN CHECKED DEPT. CHECKED DATE DA TT 1iI111110110 loop s11111111111 Ijijidhlilpird gploomou -. Hill LLOS likell1111 1111.1 WOMEN'S . mgig LC SUBTITLE ON MAINS 2-1/2" & LARGER @ 0 BUILDING 9-96 TENANT IMPROVEMENT #4 ri iii mime ei rte. rt GENERAL NOTES: CONSTRUCTION NOTES: 1. THIS AREA HAS NOT BEEN VISUALLY SURVEYED FOR CONDITIONS INCONSISTENT Will THE AS—BUILT INFORMATION. UNLESS NOTED FOR BRACING; CONTRACTOR TO VERIFY EXISTING FP MAINS ARE NOT OF SUFFICIENT SIZE TO REQUIRE BRACING. ALL KNOWN MAINS ARE NOTED FOR BRACING, BUT VERIFY THAT NO OTHERS EXIST. [2:2, NOT USED. [2:>, BRACE PER 2M262 2ND FLOOR FIRE PROTECTION PLAN 2M262 M521 FIRE PROTECTION MAIN SIZES WERE NOT PROVIDED IN THIS AREA. CONTRACTOR TO CONFIRM MAIN SIZES. 4 SPRINKLER HEAD DROP INTERFERES WITH NEW LIGHT LOCATION. RELOCATE DROP. SPRINKLER HEAD DROP INTERFERES WITH NEW CEILING I - COFFER. RELOCATE DROP. U >. RELOCATE SPRINKLER MAINS & BRANCHES INTERFERING WITH NEW STRUCTURAL X-BRACE INSTALLATION & LOCATION. FIELD COORDINATE. CURRENT REVISION SYMBOL J#715225-00 - 2M262 0 I 2M260 0 2M261 4 2M263 0 I 2M264 0 I 2M265 I KEY PLAN 08.10.01 PLUMBING FIXTURE CONNECTION SCHEDULE MARK NUMBER DESCRIPTION CONNECTIONS (INCHES) TYPE BASIS OF DESIGN SAN VENT HW CW P -1 WATER CLOSET 4 2 - i' WALL -HUNG, SENSOR- OPERATED FLUSH VALVE KOHLER STRATTON (K-4450-C) BOWL WITH LUSTRA SEAT (K- 4666 -C) SLOAN OPTIMA 8110 -LH -MC FLUSHOMETER P -2 WATER CLOSET (ADA) 4 2 - 1 WALL- HUNG (ADA), SENSOR - OPERATED FLUSH VALVE KOHLER STRATTON (K 4450 -C) BOWL WITH LUSTRA SEAT (K- 4666 -C), SLOAN OPTIMA 8110 -LH -MC FLUSHOMETER P -3 URINAL 2 1 1/2 - 3/4 WALL -HUNG, SENSOR- OPERATED FLUSH VALVE KOHLER DEXTER (K- 5016 -ET) URINAL, SLOAN OPTIMA 8186 -LH -MC FLUSHOMETER P -4 URINAL (ADA) 2 1 1/2 - 3/4 WALL -HUNG (ADA), SENSOR - OPERATED FLUSH VALVE KOHLER DEXTER (K- 5016 -ET) URINAL, SLOAN OPTIMA 8186- LH -MC -BD (BEAM DEFLECTOR) FLUSHOMETER P -5 LAVATORY 1 1/2 1 1/2 1/2 1/2 WALL HUNG, SENSOR-OPERATED FAUCET KOHLER GREENWICH (K- 2032), SLOAN OPTIMA EBF -85 FAUCET W /MIX -75 -A. AS NECESSARY P -6 LAVATORY (ADA) 1 1/2 1 1/2 1/2 1/2 WALL HUNG, SENSOR- OPERATED FAUCET (ADA) KOHLER GREENWICH (K- 2032), SLOAN OPTIMA EBF -85 FAUCET W /MIX -75 -A; TRUEBRO LAVSHIELD P -7 LAVATORY (ADA) 1 1/2 1 1/2 1/2 1/2 WALL HUNG, SENSOR- OPERATED FAUCET (ADA) KOHLER ' GREENWICH_ -(K- 2032), SLOAN OPTIMA EBF -85 FAUCET W/MIX-60-A; TRUEBRO LAVSHIELD P -8 WATER CLOSET (ADA) EXISTING EXISTING WALL HUNG, ADD FLUSHOMETER AND SEAT SLOAN OP11MA (8110- LH -MC) FLUSHOMETER; ABLEWARE ELEVATED TOILET SEAT (F72571 -0005) P -9 URINAL (ADA) EXISTING EXISTING WALL HUNG TO BE LOWERED, ADD FLUSHOMETER. SLOAN OP11MA 8186- LH -MC -BD (BEAM DEFLECTOR) FLUSHOMETER P -10 ELEC. WATER COOLER 1 1/2 1 1/2- 1/2 WALL HUNG; ELECTRIC WATER COOLER ELKAY ERPH2-8 WITH PLUG CORD. REVISION APPROVED DATE SY REVISION BY APPROVED DATE ZLAtrizE ACCEPTABILITY This DESIGN AND /OR SPECIFICATION IS APPROVED 'APPROVED BY DEPT:' DATE DRAWN DLR GROUP - KP CHECKED ENGIN CHECKED BE 06:10.01 BTRLE PLUMBING SCHEDULE T BUILDING 9 -96 TENANT IMPROVEMENTS #4 r i nr rtiktrt rte. CURRENT REVISION J #715225' -00 SYMBOL SHEET M523 DATE 08.10.01'