Permit Description:
REMOVE AND RELOCATE, INSTALL ADDITIONAL DUST
COLLECTION SYSTEMS
REMOVE AND RELOCATE UNIT HEATER
UMC Edition: 1997 Valuation:
Total Permit Fee:
*****,** k• k******** k*****' k*****A*** k******** k**' k*' kA* * * *'k** * * *'k*** *'k **'k * * * *A*
Permit er;Author.ized. Signature
I hereby., certify that I have read and examined this permit and know the
same ,to be and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified 'Herein or not
Signature:
Print Name:
MECHANICAL_ PERMIT
Date
Status: ISSUED
Issued: 09/25/2001
Expires: 03/24/2002
Phone:
�L Date: °f- Z -5-
(206) 431 -3670
Phone: 253 773 -0444
92,000.00
82.63
The granting of this permit does not presume to give authority to violate
or canc el . the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign for and
obtain this building permit.
£ jzO i2 Title:
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or
abandoned for a period of 180 days from the last inspection.
ACTIVITY NUMBER: M01 -151
DATE: 8 -29 -01
PROJECT NAME: BOEING 9 -99 J.S.F. MODEL AREA
SITE ADDRESS: 9725 EAST MARGINAL WAY SOUTH
XX Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter. # Revision # After Permit Is Issued
DEPARTMENTS:
Bu'Ic iv'sion 1 Fire PraSVention
Public Works I I Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
TUES /THURS ROUTING:
Please Route
REVIEWER'S INITIALS:
\PRROUTE.DOC
5/99
PLAN R EVI E WI � VU1 � NG SLIP
Incomplete
Structural Review Required
APPROVALS OR CORRECTIONS: (ten days)
Approved n Approved with Conditions
REVIEWER'S INITIALS:
Planning Division
Permit Coordinator
DUE DATE: 8-30-01
Not Applicable n
No further Review Required
DATE:
DUE DATE 09 -27 -01
Not Approved (attach comments)
I I
DATE:
CORRECTION DETERMINATION: DUE DATE
Approved n Approved with Conditions n Not Approved (attach comments)
REVIEWER'S INITIALS: DATE:
.. r�r. m•. �,+.. c +wrsrr.uxa.a,.nrvgo-w:x•,:c,•no �n� +�:
August 30, 2001
Mr. John Murdoch
The Boeing Company
P.O. Box 39999
M/C 89 -15
Seattle, WA 98124 -2499
Dear Mr. Murdoch:
Th
City of Tukwila
Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
RE: Letter of Incomplete Application #1
Development Permit Application Number MO1 -151
Boeing 9 -99 Building JSF Model Area
9725 East Marginal Way So.
This letter is to inform you that your permit application received at the City of Tukwila Permit Center on
August 29, 2001, is determined to be incomplete. Before your permit application can begin the plan
review process the following items need to be addressed.
Building Division: Bob Benedicto, Plans Examiner, at (206) 431 -3670, if you have any
questions regarding the following:
1. Contaminated air shall not be recirculated to occupied areas unless contaminants have been
removed. UMC 505.3. Provide the "listing" for the Sternvent sawdust collector, shown on sheet
IMIO.
The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision
block. If your revision does not require revised plans but requires additional reports or other
documentation, please submit four (4) copies of each document.
In order to better expedite your resubmittal a `Revision Sheet' must accompany every resubmittal. I
have enclosed one for your convenience. Revisions must be made in person and will not be accepted
through the mail or by a messenger service.
If you have any questions, please contact me at the Permit Center at (206) 431 - 3684.
Sincerely,
Kathryn A. Stetson
Permit Technician
encl
File: Permit File No. MO1 -151
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206- 43/ -3b65
Sent by: DLR Group 1 GION 2064616049; 09/20/012:29PM;J #444;Page 1
SE'P -14 -01 FRI 08 :52 A!i INDUSTRIAL AIR SYSTEMS FAX NO 2063630653 P.01
� i 43l -36bS
I NDUJSTRAL . AIlt SYSTEMS, INC.
17739 -1S"t AVENUE NB • SHORELINE, WA 98155.006) 3C 511S • FAX C206)3634653
Custom Air >asndlini Units. Cabinet Helms. Galls, Gat Fired Air klaadliaj Vain, fatrj, Recovery Symms,
E apormive Cooler Smog, Computes Imam Ale Cdoditionimg Unt. Commeteid and ladurttial Osamu. Arno and
Weld Exhaust Symms. Pima and atast Aamhi. Duo Collezioa Symms. Marisa Rama ' Syttatas, WA-1W Hume
To: City of Tacoma
Prow 206-431.3685
nom
Iloi fleeing 1}499
O Ytlawt 'For Illovlow
• Attention: lob lienklictie
• Comment=
i*
JI9/*
Fax Transmittal
Fran: Jim Bradley
paves 8
t;te$at September 14, 2001
CG File
SEP 2 0 2001
DEVELOP C OMMUNITY ENT
A COPY OF THIS DOCUMENT
H AS BEEN FILED
O Please Comment 0 Pteae. Bepty sq Meese Re yyet•
See attached correspondence regarding 'Stenwent dust collector from previous project which Wayne W16ams at
DLR Group asked me to fax to you. Please call with any questions
,sajne•m
Jim Bradley Foret0A146•fp:
6040 RlP%fde4)
Q +•s ? ri vs • Etuvas
4L( Qu 4t1cY.V C,t �Tk,�:�
,.�t s1E T die 430, :K� M4G 1�'wCU' " H,Ier4tc t.
Sent by: DLR Group 2064616049; 09/20/ 2 :30PM;,fX #444;Page 2/8
R.00lvod; O/14/ 1 D :OOAM; 2O63e30e53 -r DLR Group: lupe 2
SEP -14 -01 FRI 08:52 AM INDUSTRIAL AIR SYSTEMS FAX N0, 2063830653 P.02
S aria a ctio item
- FUX 3001 type spark detector is highly sensitive and reacting without delay upon detection of
any infrared radiation for temperature up to 176 degrees F
- Single sparks or showers of sparks are detected immediately and transmits an electrical signal to
the control panel to shut down entire system
▪ Manual reset is then required for system operation .
- For use only in dark, closed environments where no ambient light can reach the detector z
- Two (2) detectors located 180 degrees apart are required ,
- Detectors provided with quick release mounting brackets for ease of cleaning and inspection 211'.
Fle 3000 control panel
U;
- 120 volt dedicated circuit provided by others c Q:
COW
Fire Ahnrr Damper 9
- Discharge hood for aborted air, co u .
wo
- Heavy duty spring assisted dampers with seals in both positions, open or abort for immediate 2 :
action upon detection of a spark or fire g a
- Automatic reset w <,
- Access door with safety switch for power cut -off w :
-120 volt dedicated circuit provided by others z
o
Retzum--AieZiltediank 111 w
- Farr Model 31. Glide Pack with Itiea Flo 200 final filters and 2" preflters 2 D `
- Housing dimensions: " H x " W x " 17 ' o
- 99% efficient on one micron particles as required by King County Fire Marshall a t.
- Dwyer 3000 Series water gaug&pressure switch provided to be installed on filter bank, shuts to u;
down the system when reaches set zraximeun pressure drop in o
-130 volt dedicated circuit provided by others fu z:
U co,
Miacellanenue Du etwor� 4e nnnr c i a
- Style HG blast gates for connection cut-offs z
- Type CWC flex hose for equipment connections where required (two feet per connection)
" diameter Pike explosion vent for installation in ductwork .
- Style FS floorsweeps for pickup
Du t1 nllectnr Noise ( l_
- Provide manufacturer- standard inlet and discharge silencers at each dust collector fan
- Fan sound power levels are tested in accordance to the latest revision of AMCA 300 in an
approved laboratory
- The silencer dynamic inaction loss is tested in accordance to the latest revision of ASTM E477
- Inlet tubular silencer to be manufacturer supplied, with blunt inlet cone removed
- Fan power levels, less silencer insertion loss, at the inlet do not exceed the following levels:
Power Level (dB re: 1 picowatt)
Frequency, Hz.: , 63 125 250 500 1K 2K 4K 8K
For non - recirculating dust collection systems, provide manufacturer- standard discharge silencer to
reduce exterior noise levels to Si dBA az 20 feet from the end of the silencer
For recirculating dust collection systems, provide manufacturer-standard discharge silencer to
reduce interior noise levels to 65 dBA in the classr000m
•.� ..,.i':.�...;5.� .r H�.t:x �i�..?:rlrs'. a:.i•k +i ; ; +i ';i;;: k'; .... .. - itir..:i:3.,':5L t.;.... .....i i'
2064616049; 09/20/0 12:30PM;,kf x #444;Page 3/8
Rt7o•lv•O: 9/14/ 1 •:00AM; 2093030003 •a DLA Group; as 3
SEP -14 -01 FRI 08;52 AM INDUSTRIAL AIR SYSTEMS FAX NO. 2063630653
Sent by: DLR Group
INDUSTRYAL AIR SYSTEMS, INC.
17739 - AVENUE NE • MOULIN& OVA90155 • (206) 3674115 • FAX (2O6) 3630653
Cuwom tic Wandlioa Units. Cabmac li ows. Cods. Gas Fired air Haaatiag that, Ee:$+ iteeavezy Systeats,
Eveputadve Cooling Sparc Cempese Boom Ali Caadiafodai Units, Cameastat and reaumziat Siirae•es. Aum aaa
Wild Exhaust Systems, Pain and Blast Booths, Dust Caawtioa Symms, lGitt:hss Saimaa as Sysosms, Itha4ta t Hearers
Tae City of Same
!°sort 206233 -7902
Phan
CC: DIR Group - Doug Halton
• . C] ument lleor Review O P eave Ca un•at ❑ Pteae Reply ❑ Flaw Recycle
• Attends= Robby Limn
• Coeovatnts PI•ssese• *timbal'.
Fax Transmittal
now Darryl Torgerson
Pagers: 6
Dotes July 3, 2001
P,_03
h
Sent by: DLR Group 2064616049; 09/20/0.-- 42:30PM;,J ax #444;Page 4/8
R.oaiv.a. 9/14/ 1 OtOOAM; 2003630863 -a OLR Group ,.404 4
SEP -14 -01 FRI 08:53 AM INDUSTRIAL AIR SYSTEMS FAX N0. 2063830653 P. 04
- Average dust loading with woodworking equipment is 5 grains/cubic foot of air (assuming all
woodworking equipment is in operation)
- Duct velocity is 3,500 FPM
- 11,520 CFM total airflow
Total Sawdust Ter Hour Day;
• 11,520 CFM x 5 grains/7,000 grains per # = 8.22 x 60 min. x 5 hours (assumes 5 hrs. operation
per day) is 2,466# per day /I5# per cu. Ft. = 164.4 cu. ft. per day.
- For this application, we can safely assume a maximum of 33% of the units running at a. given
time. Therefore, 164.4 x .33 a l 54.2 maximum cu. ft. of sawdust per day.
Total C4yttued Sawdust;
• With well designed hoods and woodworking equipment designed for a collector system, we can
assume 98% capture efficiency.
Total Amount of Sawdust Within the Ductwork at a Gives Time:
- Assuming 75 feet of ductwork /3,500 ft. per minute = .0214 minute transport time.
- At 8.22* per minute of sawdust x .02I4 transport time - . 1759# of dust in the ductwork.
Assumc .1 759# of dust in the ductwork with the dust collector capture efficiency of 99.95%
overall efficiency.
• The dust collector has an overall efficiency of 99.95% but 100% efficiency on dust particles
over 10 microns in size. (see attached from Sternvent)
- 1759# x 0.05 = .0087# of dust after the dust collector and prior to the 95% final filter.
- The 95% final Filter is virtually 100% effective on dust 1 micron and above. (See attached
chart —page 3)
- The attached chart (page 2) shows dust particles in the range of 3 microns to 150 microns. If
that were the case, the 95% final filter would capture 100% of the wood dust. However, for this
project, let's assume 5% of the product is below 1 micron.
Assume as Follows:
- .0087# x .0545 .000430 below 1 micron and 0# below .3 micron, therefore, an average
Sent by: DLR Group 2064616049; 09/20/0,i_42:31PM;J@t #444;Page 5/8
N•Oetvad1 O /14/ 1 • O1AUp 2063630663 -r OLP Group; , age S
SEP-14-01 FRI 08:53 AN INDUSTRIAL A I R' SYSTEPIS FAX O. 2063630653 P. 05
efficiency of 90% may apply.
- .00043 x .1 = .000043# of dust per minute after the final fIter.
- Total airflow - 11,520 C.FDvi = 326.24 cu. meters per minute.
• .000043# of dust = .0195 grams.
- .0195 grams/326.24 cu. meters = .000059 grams/cu. meter.
•
- .
........--_____ . C
CI
IAIQ[B
N M{
OWN. 1
CWK .
iCAi!
STERNVENY CO. INC.
26 CARROLL STUKOT
BROOKLYN, N. Y. 11531
FACTIONAL EFFICIENCY CURYK
No. 109070
•
FRACTIONAL COLLECTION EFFICIENCY
VS
PARTICLE SIZE
FOIL ENVELOPE TYPE /URIC FILTERS
•
I
NII1tit INC - MORON
NOTICE: IF THE DOCUMENT IN THIS. FRAME IS LESS CLEAR THAN
THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT.
I -
0
ao
a)
D 7
• e+
n
th • a
m P- ` C
" •
.-.
t �
O o
:° ▪ � - U
0
is
o
V]
.-r
O A
O
O
tra
N O I
Oh
•
„ Y
O
r
x n
O O
N 0
• C
Of
O w
fy
a1
(A) O •
w
Sent by: DLR Group "1 2064616049;
Received: 2 /14/ 1 0 0IAM; 2063030663
• SEP -14 -01 FRI 08:53 AM INDUSTRIAL AIR SYSTEMS
/
PARTICLE SLZE zinaENC.Y
DIMENSIONS & PERFORMANCE DATA
far Owai sN&saast as pages Coat
09/20/02 --1 2:31 PM;Jgx r#444;Pege 7/8
-> DLA Groi ; ap. 7
FAX NO. 2063630653
2
PARTICLE S0E (MfCA0K$)
142731' frai washar taaisa laa s 150•F 3C) catu laaaa a a SOQV 4900 WerloSOM82
3
5 6
1MFti11C CONVERSIONFORKULAS
hciscs to :r;ctt .... Inches x 25..i
:bs. m 44 Lbs. x .4536
Itches %. . to 1:1)3 Inches •v S. x .2488
tc m /11 - CFM x 1.6992
Ft= to ta= Ft x -0929
20x20
13 x 24
11.38
20320
20 834
24Y24 ' 2333
12 :24
20220 • 19.38
• 20x2
• .12
• 20 •
20S24
19.38
29.38
12.38
1938
1138
19.38
19,35
23.38
19.38
33.38
23.38
23.38
23.38
23.38
19.31
2338
F
1+10 .25
1.5
39
1400
1000
.29
2.5
28
1400
.29
2.3
39
]000
19.38
1400
1111
ZOO
1000
2400
.50
1.5 28
.50
.50
.50
.68
1.5 f 47
1 -5 51
1.5
1.5
1.5
1.S
28
39
47
1660
2000
750
1050
1245
1500
600
840
'
1200 •
600
$40
995
.30
.30
.30
32
32
.41
.41
.56 '
.56
,56
56
1S
13
1S
1.5
1.5
1.5 •
INEENI
1.5 •
1.5
1.5
25
19
24
19
24
1 4
24. •
• 29
• i4
19
24
29
P. 07
8 10
Sent by: DLR Group
i.t1i( ICll>t(\.__
tied i &I srr% ice 1 i � C
1116 f r7 o
Reel. ea: 9/14/ 1 0:01AM; 2003030S53 -' OLR GrOup; ape 8
SEP -I4 -01 FRI 08:54 AM INDUSTRIAL AIR SYSTEMS FAX N0. 2083630653
0.01
Totally Rigid, Disposable Air Filter
RIGA -FLO FILTERS are available in a range of
a ltrazion efficiencies to match each application's
needs Although a disposable 5ker. the RIGA -FLO
is completely rigid in conduction, assuring
strut u L and performance integrity throughout
its entire service life. RUGA.PL0 filters arc ideally
suited to variable volume Syste:as. Being totally
rigid, performance is net affected by changes in
air velocity or fan shutdown, and thdr cauCgctira-
don is not altered by accumulation of dirt.
HIGH LOFT MEDIA is laminated to a nonwoven
synthetic backing, which provides positive
support, optimize' dust dust holding capacity, and
precludes fiber emission. as compared to flat glass
at media.
DURABLE AND RELIABLE all :metal contour
stabilizers. diagonal support bracing. galvanized
steel enclosing flame and welded wire me
support grid provide rigidity, durability, consistent
integrity and pesfotmwcc reliability through=
the filter's life. The RIGA -FLO is capable of
EFFECTIVE FILTRATION RANGE
NOT NASIDIX To THE EYE
.1 t
F
FUMES
FOG
MOLDS
BACTERIA
POLLEN
OESCENDINO IMPURRIES
OUST
FLY
MISTS
RAIN
HEAVY INDUSTRIAL OUST
TOBACCO GNOKS
OIL SMOKES
•
t .
SUSPENDED IMPURITIES
0.1
2064616049;
10
MICRONS
09/20/01.d #444;Page 8/8
withstanding 10" w.g. pressure drop without
noticeable diawrcori of the media pack.
LONG SERVICE LIFE - The lofted media and
Fur's exclusive tapered radial pleats provide a
high dust holding capability, =tending the life of
the filter. As a result, the system will require less
downtime and maiatcnance.
ENERGY CONSERVATION - The RIGA FLO
will operate at air volumes considerably below
rated velocity (500 fprn) and capacity. Initial
resistance is reduced and performance is
iniproved..;a -vice life is cmtmdcd and energy
savings can be sizable.
INSTALLATION EASE - RIGA -FLO filters are well
suited to tither built -up banks or Farr side access
systems. RIGA -FLO filters are available standard
with no header or with 7/8" or 1 1/S" headers.
(See BIGAFLO/PH Bulletin No. A-1306-4-)
RIGA-FLO is adaptable to both competitive and
OEM housings.
VISCIaLS To THE ENS
100
•
1.000
ar
P. 08
10,003
'yfia.'.b. r''!�� }uf.69Y�; '•x:'4- ,�''.` .`�"sd'i£W�Sh'�.6dr".�A'�
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M01 -151 DATE: 8 -29 -01
PROJECT NAME: BOEING 9 -99 J.S.F. MODEL AREA
SITE ADDRESS: 9725 EAST MARGINAL WAY SOUTH
XX Original Plan Submittal Response to Incomplete Letter #
Response. to Correction Letter # Revision # After Permit Is Issued
DEPARTMENTS:
Building Division
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 8-30-01
Complete n Incomplete Not Applicable
Comments: 5CC C:owA44AetA41 Ot& ‘reOctrse sKir o 4-t SLe e*.
TUES /THURS ROUTIN :
Please Route Structural Rev Required n No further Review Required
REVIEWER'S INITIALS: ' I DATE: S /O,ZOO/
APPROVALS OR CORRECTIONS: (ten days)
Approved n Approved wit Con �iti• s Not Approved (attach comments)
REVIEWER'S INITIALS: � r DATE: 6 1
CORRECTION DETERMINATION:
Approved n
\PRROUTE.DOC
5/99
DUE DATE 09 -27 -01
Approved with Conditions n Not Approved (attach comments)
REVIEWER'S INITIALS:
DUE DATE
DATE:
ui'.f , ?.:U4 0ri, »n.,
•
t.oK-V am%IA a +cd air sInca a A e . r'e w� o 1 cd
tay.tesS C O K4Ct tv\gv�,
TIroutde --kc 'iLV�- 4'o11 +1AC. StcrK.ie. t4
.514.0u.0% oK Sketh IMtO/
- occupied G ircas
UMC SOS .3 ,
So dust Cot Iec*o
•
F
W O
J
z
2 Mt
m p
ON
`D F-t
;W W�
Z
UI
O '
z
PERMIT NO.:
MECHANICAL PERMIT APPLICATIONS''
INSPECTIONS
Mot-II ,.
❑ 00002 Pre - construction
❑ 00050 WSEC Residential
❑ 00060 WA Ventilation/Indoor AQC
❑ 00610 Chimney Installation/All Types
❑ 00700 Framing
❑ 01080 Woodstove
❑ 01090 Smoke Detector Shut Off
❑ 01100 Rough -in Mechanical
❑ 01101 Mechanical Equipment/Controls
❑ 01102 Mechanical Pip/Duct Insul
❑ 01105 Underground Mech Rough -in
❑ 01115 Motor Inspection
❑ 1400 Fire Final
O 01800 Final Mechanical
O 04015 Special -Smoke Control System
CONDITIONS
0001 No changes to plans unless approved by Bldg
Div
❑ 0014 Readily accessible access to roof mounted
equipment
❑ 0016 Exposed insulation backing material
O 0019 All construction to be done in conformance
w /approved plans
❑ 02 Plumbing permits shall be obtained through King
Co
0 27 Validity of Permit
003 Electrical permits obtained through L & I
0036 Manufacturers installation instructions required
on site
❑ "BTU maximum allowed per 1997 WA State Energy Code"
❑ 041 Ventilation is required for all new rooms &
spaces
0005 All permits, insp records & approved plans
available
• "Fuel burning appliances
❑ "Appliances, which generate...."
O "Water heater shall be anchored...."
Additional Conditions:
TENANT NAME:
FEES
Basic Fee (Y/N)
Supplemental Fee (Y/N)
Plan Check Fee (Y/N)
FurnaceBumer
to 100,000 BTU (qty)
Over 100,000 BTU (qty)
Floor Furnace (qty)
Suspended/Wall/Floor - mounted Heater (qty)
Appliance Vent (qty)
Heating/Refrig/Cooling Unit/System (qty)
Boiler /Compressor
to 3 HP /100,000 BTU (qty)
to 15 HP /500,000 BTU (qty)
to 30 HP /1,000,000 BTU (qty)
to 50 HP /1,750,000 BTU (qty)
over 50 HP /1,750,000 BTU (qty)
Air Handling Unit
to 10,000 cfm (qty)
over 10,000 cfm (qty)
Evaporative Cooler (qty)
Ventilation Fan (qty)
Ventilation System (qty)
Hood (qty)
Incinerator — Domestic (qty)
Incinerator — Comm /Ind (qty)
Other Mechanical Equipment (qty)
Other Mechanical Fee (enter $$)
Add' 1 Fees — Work w/o Permit (Y/N)
Insp Outside Normal Hours (hrs)
Reinspections (hrs)
Miscellaneous Inspections (hrs)
Add'l Plan Review (hrs)
Plan Reviewer.
Permit Tech:
,F evin 5 c i
acai
2
Date: qr Z
Date: '" — 2446(
ACTIVITY NUMBER: M01 -151 DATE: 8 -29 -01
PROJECT NAME: BOEING 9 -99 J.S.F. MODEL AREA
SITE ADDRESS: 9725 EAST MARGINAL WAY SOUTH
XX Original Plan Submittal
Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Is Issued
DEPARTMENTS:
Building Division
Public Works
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
TUES /THURS ROUTING:
Please Route I I Structural Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS: (ten days)
Approved
REVIEWER'S INITIALS:
CORRECTION DETERMINATION:
Approved Approved with Conditions
REVIEWER'S INITIALS:
\PRROUTE.DOC
5/99
PLAN REVIEW /ROUTING SLIP
Fire Prevention
Structural
Incomplete
A rove with Conditions
Planning Division
Permit Coordinator
DUE DATE: 8-30-01
Not Applicable
No further Review Required
DUE DATE 09 -27 -01
Not Approved (attach corn ents)
DATE: 910 d! 1
n
Comments:
DATE:
DUE DATE
Not Approved (attach comments)
DATE:
Project Name/Tenant: 9 .. Qo/ A ?5 mow, _ g alue
of Mechan4Dtment:
Tax Parcel Number:
Site Address :qz9 a ... Z / e , i t y Stat O p ; ws
Property Owner:vie Nem& &mow
Phone: (266) /15 ..
Se. ddd ICJ/` mil `l
N/c gills d ayfriteityliOip:
Fax #: (/�L' )
1 7 j
7
.. �r LJ{''( '3�1 _
V
Contractor:
Gl y iv' j
Phone: ( ( � v 1
Street Address:
City State /Zip:
Fax #: ( )
C ct r
P s; o
g m
• # e R6( ` o ,, y
j'� V
Phone: ()
14
v
wgic
39 Q9 MIc- Ise lame y a Z ip:
Fax #: )
` 25 3 3
44
4
CITY OF T . KWILA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
' STAFF 41SE ONLY
Project Number:
Permit Number:
MD I• X51
Mechanical Permit Application
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT)
Descr of work to i doe (please cific)_ vgi , w s rri _ „ _ Du 2
a T9M
W e ' RaDcare c)bI r
Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of
application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor
Registration ".
Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the
State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the
permit will be required as part of this submittal.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDIN � - ER i R AUTH RIZE AGENT:
Signature %� AA� / -r1 ROM& C01 / V
l� DON . MOM 1� Phone: (M) 4 i
Wit 1
Print na
A` eb • Box 319/ M C81 IC
Date/r0( MJI z0Dj
Fax #: (%3) /151:7132
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written
request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be
extended more than once.
Date application accepted:
Bad O/
Date application expires:
Application (initials)
11/2/99
reel; penult doe
✓
Submittal Requirements
Floor plan and system layout
Roof plan required to identify individual equipment and the location of each installation (Uniform
•Mechanical Code 504 (e)) , ,
Details and elevations (for roof mounted equipment) and proposed screening
Heat Loss Calculations or Washington State Energy Code Form . #H -7 ,
H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut-
off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical
Code 1009).
Specifications must be provided to show, that replacement equipment complies with the efficiency ratings
and other applicable requirements of the Washington State Nonresidential Energy Code.
Structural engineer's analysis is required for,new and the.replacement.of existing roof equipment
weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be
stamped by a Washington State licensed Structural Engineer.
Mechanical Permits
COMMERCIAL: Two complete sets of drawings and attachments required with application submittal
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced..
RESIDENTIAL: Two complete sets of attachments required with application submittal
11/2/99 .
nslscnun.duc
Submittal Requirements
New Single Family Residence
Heat loss calculations or Form H-6.
Equipment specifications.
Change - out or replacement of existing mechanical equipment
I Narrative of work to be done, including modification to duct work.
Installation of Gas Fireplace
`.Narrative with specification of equipment and chimney.type:
If using existing chimney, provide a letter by "a certified chimney sweep stating that the chimney is in safe
• condition.` •
NOTE:' Water heaters and vents are included in the Uniform Mechanical Code = please include any water
heaters or vents being installed or replaced.
UREAU .AT (!206)575-4407.
CITY OF TUKWILA
'Address: 9725 EAST MARGINAL WY S Permit No: M01-151
Suite:
Tenant: BOEING #9-99 Status: ISSUED
B-MECH Applied: 08/29/2001
#: 000340-0018 Issued: 09/25/2001
:******************************•A********W*******Al:************ k********
Permit Conditions:
1. No changes will be made to the plans unless approved by the
Engineer and the Tukwila Building Division.
• All permits, inspectitinrecordsand approved plans shall be
available at the •lObsite,prior to tWe'start.of any con-
struction. Tbesse'documents to be maintained and avail-
, .
able until :final inspection approval is granted.
•
All constr:Uction'to be done in conformnce, with approved
'. - 4
,plans andrequlreMents of the Uniform Building Code , 09.7
EditioWas„!amended, Uniform Mechanical Code ,1997 Edition),
and WasnTn4ton'State'EnergyCode (1997 Edition).
.-
• Vali di•ty of Permit. The iSSuancp, of a permit or approval of
. t ,
'plans:4, , i specificationh. apd. computations shall 'be con-
stiled Wbe a,ipermit'•for ,
,.',.or a approval of, any.violatiOn
offily of the of the building code or of any
other ordinance of.. the jurisdiction. No permit - presuming'. to
OVe authority to yiol cancel - the provisions of this
tode shall be valid.
5. Manufacturers,cnstaliatfon instructions required on Site
for' theAJuild'frig review. " •
6. 4 4 1 ,iFIREDEPARTMENT coNbiTIoNs*.k* * ,
. , .
7. Et,odu6t;conveying/duOt Systems ,shall comply with UMC 1997
COapter 6, SectiOn'609'
THESEU REVIEWED BY INSPECTOR 510. IF YOU HAVE
ANYi PLEASE CALL THE TUKWILA FIRE PREVENTION
, •
•
• . A:v
herebkOrtify that I have read these conditions and will comply
them\as All provisions of lavand,OrdipanceS
this work *S11 be,..,compiled with, Whether specified herein or not
.•
he grantinT0f,this-permit does not presume to give authority to
-
.violate or cancel, the provisions of any other work or loc laws
• ,.
regulating constrliction or theRarfc0"maii,ce of work.
': ' ,' ,, .• ,
'',',, .`; _ •", : 4 , „
ignat6re: -
.:- ..:::„, Date: _29:2,74.2.....:7.L2/
1printAaMe
Cr:4TYOFTI-J
*
jwANPmIt "M
PaY4Oit Met
in it
Parcel
1!3 Pytoen
,
vc:;
1100unt Cad
000/345A30
.000/32420
TRANSMIT
C%-*********A-:c******4*t.1**4*.A*****.A
be'r: 80101253 Amount: 82.63 09/25/01 14:06
NOtationt'BOEING Init: KAS
No: M01-151 Type: B-MECH MECHANICAL PERMIT
No: 000340-0018
eq 972' EAST MARGINAL WY S
Total Fees: 82.63
t 82.63 Total ALL •Pints: 82.63
Balance: .00
•
Descriptlon Amount
-PLAN CHECK NONRES 1
MECHANICAL - NONRES • 66.10
8o-eit>yiod, JA,b(A-t Oco
000, qq,S8b. q0S
'lig" 09126 9716 TOTAL.
0.0i)
Project: , , Yv ,'
Type of Inspection:
0
Address: ' .
Date called:
Special instructions:
Date wanted:
Requester:
Phone:
INSPECTION RECORE
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter B I vd, #100;: Tukwila WA 98188
COMMENTS:
. •
•
ynspettOr
Date: (......
r-• • • I . •
, - • • • "•17' • •
• • ,..• „
PER
(206)431-3670
Approved per applicable codes. El Corrections required prior to approval.
• ;$47.00 REINSPECTIO E REQUIRED. Prior to inspection, fee must be paid
t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
ReeeiPt No:
Date:
' • ,
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila WA 98188
Address:
Special instructions:
Type of Ins ection;
Date called:
Date wanted: ;.
Requester:
Phone:
COMMENTS: // � /
) 41
3 An.. r l � -ms
Approved per applicable codes.
jJ S47 EINSPECTION (E REQUIRED. Prior to.in•spection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No:
Date:
,viyk^h.1�';�(fi:rr*4
INSPECTION RECORQ
Retain a copy with permit
L5
PERMIT NO.
(206)431- 3670
Corrections required prior to approval.
,Eroject:
150elrYi
c i- 91
Type of Inspection:
-K og 0 - I v
Address: ,../ . . i ,
f //Mr ltrt 1 /-:::), _3
Date Mica
L lc — C ) •
Special'instructions:
Date wanted:
I CO ' 0 2-
0.m.
p. --- w --
Requester:
Phone:
SPECTION RECORD
• Retain a copy with permit'
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 98188
746 /
PERMIT NO.
(206)431-3670
Approved per applicable codes. Corrections required prior to a'pproval.
COMMENTS:
\Inc dowl .51 -c
ck0A-
Ck.p? rn0e61
Ci 11 )0P IL_ 41 e
),N1'001rvlif rt \f\ -PcA4--Pr t cr C
o
o■)e
c.vol v "cl
f ; e 6,--vt1
•
Date:
* / to' 02
$47.00 REINSPECTION FIE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.'
Receipt No:
Date:
4„ '
1
1
:7 , Z:1 „ . .r , . : s r • . 7. ”. •
s•■• , T• • • *I ` 40 ' •-• , r14,1-17. 4 ( ;,,, A. \,$1.4,4 , • .'r. , 4• ,0 1 , P • ' rtr4i . 0"r•t7.)% '‘
• .• •
f
• ; •
Needs shift inspection
• Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre-Fire
Permits:
Author-ited Signature
FINALAPP.FRM
• City of Mkwila
Fire Department
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Project Name B(W (:>) ‘' 30
■rs
- Address c3- Z._ 5 E (irsL s
Retain current inspection schedule
Approved without correction notice
Approved with correction notice issued
Thomas P. Keefe, The Chief
Permit No. 0 k
1 0
Date
T.F.D. Form F.P. 85
John W. Rants, Mayor
Suite #
ft
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 375-4404 • Fax (206) 575-4439
•",
4 7:7, '7 .‘ ;•:„ Avg.".4
—
City of Tukwila
Department of Community Development
March 18, 2002
Mr. John Murdoch
PO Box 3999
M/C 85 -15
Seattle, WA 98124
RE: Permit Application No. M01 -151
Location: Boeing 9 -99
9725 East Marginal Wy S
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of
Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit
issued by the Building Official under the provisions of this code shall expire by limitation and become null
and void if the building or work authorized by such permit is not commenced within 180 days from the date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time
after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
• Call the City Of Tukwila Permit Center at (206) 431 -3670 to schedule a
progress or a final inspection
A progress inspection is intended to determine if substantial work has been accomplished since issuance of
the permit or last inspection; or if the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve a one -time
extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why
circumstances beyond the applicant's control have prevented action from being taken.
In the event you do not call for the above inspection or request and receive an extension prior to March 24,
2002, your permit will become null and void and any further work on the project will require a new permit and
associated fees.
Thank you for your cooperation in this matter.
Sincerely,
gat h,
�tkiyu ct , C O34) u
Kathryn A. Stetson
Permit Technician
Xc: ;Perrt it File. No:M01-151
'Duane Griffin, Building Official
Steven M. Mullet, Mayor
Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665
I
ABLATIVE COATING FACILITY
BIB LAB (PERMIT PACKAGE)
REVISION
�:r MODEL AREA. Ina # 19002c OG
VJ vi•JVII VvV LJ -
PF. -CT
SI
\cxeoo, B? C'GE
OXBOW LCT
VICINITr MAE
FROM DOWNTOWN SEATTLE
(---,,:/,
FROM SEATLE- TACOMA AIRPORT
DEVI=LOPV
I L L /i
I'
I EAST MARGINAL WAY
CORPORATE PARK
99
J #757566 -07
J #180015 -06
B18 LAB (PERM T /CONSTRUCTION PACKAGE) 0180138-00
RELOCATE R &. E STORAGE 21 -03 TO 9 -99 J #180138 -00
BCE
S Pt)
�l
EXIT
ENTAL_ CENTER
900
157-
DATE
APPROVED
NG INPORN4ATON, SPACE & 3FPHNSE SYSTEMS
9 99 BL, LD \G - JS= V OD -L AIPPA
0
D
\
✓ \ \ \ \
\
FROM KENT 90
& .AUBI_ RN \
\5
12.18.96
11.03.98
1 98
04.07.99
07 0c 99
V / .VV. J
- EXIT
NO SCALE
157
AREA MA
REVISION
9 -99 MODEL SHOP - PHASE 1 & 2
BUILDING ADDRES
9725 EAST MARt3I \AL WA' SOUTH
TUKWILA, WASH: N GTO N
MECHANICAL PERMIT /CONSTRUCTION PACKAGE
BOEING DEVELOPMENTAL CENTER
9725 EAST MARGINAL WAY SOUTH
TUKWILA, WASHINGTON 98108
J #1 -0 0
BY
DLR GROUP
APPROVED
R. GWINN
BUILDI \G 9 -99 LOCATIO
M 0 I ■•■ 5 1
DATE
7 -31 -01
NO SCALE
GENERAL NOTES
A
**
el.isrderEvrAvAg
CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA, MUST
BE ON SITE DURING CONSTRUCTION. 2 NOT PROCEED WITH CONSTRUCTION WITHOUT
ABOVE MENTIONED SET OF DOCUMENTS.
1 CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDIT'ONS BEFORE COMMENCING WORK.
2. NOTIFY CARSON HORNOR, CONST. MGR. (206)544 -2668, IF EXISTING CONDITIONS PEQUIPE
DESIGN REVISIONS.
3. COORDINATE WORK WITH OTHER CRAFTS.
4. RETURN THIS SAME SET 7- 2 JOHN MURDOCK AT BUILDING 9 -51.2 COLUMN N /1,
AFTER COMPLETION OF THIS CONSTRUCTION.
5. RETURN COMPLETE CONSTRUCTION "AS- BUILT" REDLINED DRAWINGS TO
CARSON HORNOR, CONSTRUCTION MGR. AFTER COMPLETION OF THIS CONSTRUCTION.
6. CONTRACTOR TO MAINTAIN CONSTRUCTION AREAS CLEAN, ORGANIZED SAFE CONDITON.
MAINTAIN "CONSTRUCTION ZONE" THAT ALLOWS ACCESS TO OTHER OPERATING AREAS
KEEP DUST & DEBRIS CONFINED WITHIN THE CONSTRUCTION SITE.
7. CONTRACTOR TO NOTIFY CONST. MGR. OF ANY "ENVIRONMENTALLY HAZARDOUS" MATERIALS
FOUND MAINTAIN "CONSTRUCTION ZONE" THAT ALLOWS ACCESS TO OTHER OPERATING
AREAS.
8. ENERGY CALCS. NOT INCLULDED. UNINSULATED TRANSPORTATION DOORS REPLACED WITH
INSULATED DOORS. NO CHANGE IN ENERGY USAGE FOR HEATING & COOLING EQUIPMENT.
9. CONSTRUCTION MAILS. CALLED OUT OR SPECIFIED ON DRAWINGS.
CHECK
BOX
PROJECT C H EC
< L ST
® THESE DRAWINGS CONFORM TO THE 1997 U.B.C., U.F.C., U.P.C.,
AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES,
AND COMPLIANCE WITH CITY OF TUKWILA ZONING
ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10 -A
BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION.
NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE:
® 1. TENANT IMPROVEMENT (STRUCTURAL):
® 5 SETS OF ARCHITECTURAL DRAWINGS
5 SETS OF STRUCTURAL DRAWINGS
5 SETS OF STANDARD DETAILS
❑ 5 SETS OF ENGINEERING CALCULATIONS
A ❑ 5 SETS OF ENERC ' CALCULATIONS (* SEE GEN. NOTES ABOVE)
** S 5 SETS OF CONST. SPECIFICATIONS (A* SEE GEN. NOTES ABOVE)
❑ 2. TENANT IMPROVEMENT (NON- STRUCTURAL):
❑ 4 SETS 9F ARCHITECTURAL DRAWINGS
❑ 4 SETS OF STANDARD DETAILS
❑ 4 SETS OF ENERGY CALCULATIONS
❑ 4 SETS OF CONSTRUCTION SPECIFICATIONS
❑ 3. TENANT IMPROVEMENT (REVISION), 2 SETS.
• 4. MECHANICAL, 4 COMPLETE SETS.
® 5. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS.
BRIEF PROJECT NARRATIVE:
1. REMOVE RELOCATE INSTALL ADDITIONAL DUST COLLECTION SYSTEMS.
2. REMOVE & RELOCATE UNIT HEATER
ACCEPTABILITY
THIS DESIGN AND /OR
SPECIFICATION IS APPROVED
DRAWN
E.DUARTE
CHECKED
D ATE
09.16.93
DEPT.
DATE
ENGINEER
PP ROVED
APPROVED BY
APPROVED
09.16.93
SUBTITLE
T ITLE
SHT.h
U1
1A0 1
- Y
- I 1 A i C
1A1'C
A60F
1A10
1A11
A5' C
A50
; --
I Cl
1
C -1
C -5
C -6
C \ 4
C - -s6
• it`:.-)R
0 1M1'R
1 M2F:R
1'M2G1R
1 M6GR
1M6iR
• 1M1C
• 1Mli
4 1 M260
1M261
• 1 M6C
1M6':
M52
M522
• M52.:
ARCHITECTURAL MAS'::
By f <-�! -
J 'C6
j •
i
pate
Permits No.
ARCHITECTURAL
T T LE SHEET / INDEX - REV. D
EXIT'NG PLAN - REV. D
LAND SE CODE
BUILDING CODES
OCCUPANCY GROUP
CONSTRUCTION TYPE
FLOOR AREAS:
BUILDING FOOTPRINT
BUILDING GROSS
rin_r FLOOR
SECOND FLOOR
PENTHOUSE
BUILDING HEIGHT
STORIES
OCCUPANT LOAD:
HANDICAPPED REQUIREMENTS
FIRE I 'ROTECTION
SEISM' ZONE
TITLE SHEET
9 -99 MODEL SHOP - PHASE I & 2
BUILDING 9 -99
COL. A -G/1 -4
unders:aric'rat t'•e F C'e , p 3ia:s a:e
iut1,@Ct !J efacyc aro ctr!ss or'S a,M acif ro ;'aI
plans does r.ot a.., i - ze tr.e viciaLor ar
adopted code 'o( oii_:.`a ^Te. Rer;e'lri! ' CQ,r,.
*-ratm e's copy ;,f a;,,, 3r&c ; ' arA
SHEET TITLE
FLOOR PLAN, DEMOLITION
FLOOR PLAN, DEMOLITION
EXTERIOR ELEVATION, DEMOLITION
FLOOR PLAN - REV. 9
FLOOR PLAN - REV. I
MISC. SECTIONS & DETAILS - ORIG
EXTERIOR ELEVATION - REV. B
DRAWING INDE,x
1-
PAR (IAL YARD PLAN - ORIG.
CANOPY LAYOUT PLAN - ORIG. —
GRAD'G - REFERENCE - 109 -000 -1129
GRAD - REFERENCE - 109 -OOC -1129
C'V!L DETS. REFERENCE - 109 -000 -1157
CIVIL DETS. REFEREN SE - 1C9 -000 -1157
DETAILS - REFERENCE - 1CC- 000 -1103
• DETAILS - REFERENCE - 1;.19- 000 -1103
DETAILS - REFERENCE - 109 -000 -1103
MECHANJOAL
PLAN - HVAC DUCT - REMOVAL
PLAN - HVAC DUCT - REMOVAL
FIRE PROTECTION - REMOVAL
FIRE PROTECTION - REMOVAL
PIPING - REMOVAL
PIPING - REMOVAL
PLAN - HVAC DUCT
PLAN - HVA_; DUCT
FIRE PROTECTION
FIRE PROTECTION
PIPING
PIPING
SRE•IFICAT ONS
DETAILS - DUST COLLECTION
DETA.,LS - DUST COLLECTION
CODE S
Jv
DC
SHT. NC.
S1 I ABBREVIATIONS, LE=END & DWG LIST
• S20 ' Cr NERAL NOTES
S2b GENERAL NOTE
S21CR N. & 'A WALL REMOVAL ELE.
-- _f-
S210 N & W WALL FRAMING _ EI_EVA T',S
S516 INT. WALL FPAM'G SETS. & SECTS.
i ! MISC. SECTIONS & DETAIL
S518 L MISC. SECTS ,DETS & S'OFAOE PA.C� :S'
S519 MISC. SECTIONS & DETAILS
. S520 T_P. LIGHT GA. STL =P DETS
S52 TY . LIGHT GA. ST'_. FIRL,M'G DETS.
5 522 INT. NON -STRUCT LIGHT GA. RFAM G
S4 . CANOP'' OF—c. ROE. 1 09-000-1157
S5 CANOPY 25 FEE. 109 -000 -1157
VARY
JOB NO.
ELECTRICAL
E1 /� I ...
L~ •.J IC'AL
HP CANOPY ILIUM NATION PLAN
E 10AR LIGHT'G & POWER "STORAGE SHEDS"
1 E I FOR PARTIAL LIGHTING PLAN
1 E1 1 R PARTIAL LIGHTING PLAN
1E6OR PARTIAL 208/120 VOLT POWER PLAN
1 E61 R PARTIAL 208/120 VOLT POWER PLAN
1E1 10R PARTIAL 480/277 VOLT POWER PLAN
1E1 11 P PARTIAL 480/277 VOLT POWER PLAN
1E161R 400 Hz &DC POWER PLAN
1E4' 1 R PARTIAL FIBER OPTIC PLAN
1E412R PARTIAL GIBER OPTIC PLAN
E3 4 80/277V &208/120V PWR MAIN FDRS
E4 SINGLE LINE DIAGRAM
E8 CANOPY ILLUMINATION PLAN
E9 — GROUNDING PLAN
1 1E10 PARTIAL LIGHTING PLAN
1E1 1 PARTIAL LIGHTING PLAN
TUKWILA
1997 U 8.C., ').F.C., U.P.C., AND THE WA.0 51 -2 ,A NO"'
ADAPTED OR AMENDED BY LOCAL ORDINANCES, o!`''F-
AND COMPLIANCE WITH CITY OF TUKWILA ZONING.
GROUPS B AND F -2 (OFFICE AND FACTORY) SEP 2 4 20
-
TYPE II, NON-COMBUSTIBLE
59,292
67,799
59,292
4,082
4,425
44 FT.
3
NO CHANGES
BARRIER FREE
FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT
3
LIRPENT REVISION
1000 - 00
SHEET
PERMIT SET
M 1
100O
rlI 'SiF'.I
U I �,iA/�
s; MBOL n
L_!
` 1
SHEET TTY
001
PEWIT CENTER
COMP NO.
1 E C PARTIAL 208/120 VOLT POWER CLAM
1E6 PARTIAL 208/12C VOLT POWER Poi- N
1 E 1 10 PARTIAL 480/277 VOLT POWER PLAN
1 E1 11 PARTIAL 480/277 VOLT POWER PLAN
1 E41 1 PARTIAL FIBER OPTIC PLAN
_ 1E412 PARTIAL FIBER OPTIC PLAN 1E501 f DUST COLLECT INTERLOCK 4 MACHINE
E502 + LIGHTING CONROL DETAILS
DATE
7 -31 -01
c
C,
C,
DWG NO. AA A i /gi [ `
,'M
REVISION
BY
APPROVED
DATE
_ rM
REVISION
By
APPROVED
DATE
A
P �9
STRUCTURE LAB UPGRADES
KGP
-99 MODEL SHOP - PHASE 1 AND 2
J# 100015 -01
DLR GROUP
RP
07.31.01
1
L__
(\EF )
A '
10,00C CFM
3 HP 480V 3 -PHASE
10,000 CFM
3 HP 480'v 3 -PHASE
KEF
C
-
r
I-
IN_► AENTATlION
~AILc1
1
I C J
500 !KIP
e ) i2B4!7ALL7A/G
T-
24 "0 DIFFUSER
2500 CFM
ACCEPTABILITY
THIS DESIGN AND /OR
SPECIFICATION IS APPROVED
Mu (•1
DATE
ENGINEER
DAWN
PENROD
CHFCI ED
CHECKED
Ae0POVEA
DA E
8 -15 -93
24"o DIFFUSER
2500 CFM
SUBTITLE
TITLE
EXISTING
MECHANICAL MASTER
J
MA.TCHLINE
PLAN - HVAC DUCT
g MODEL SHOP - PHASE 1 AND 2
BUILDING 9 -99.1
COL. A -C/ 1 - -4
REMOVAL
• ASKSTCk NCTIF::Ai
A 9c-)1 'cr- -°`..^ Sar,oei •ne fcn. area •'GS Dee" conducted '3"?' osbestC
contc'*r g '-•oter *as not 1.scc trot .ec.Id ae involve! t the
canst.:.ct,:z T•i =s pro _t Do not rerr:we. damage ®r
.Sbestc's rnORE -j OdyXe T •r' the If4Y1 ' 4Y1, area. Please = Dr,1 • 9,
Focht es eC 'men.' _ ;estas -_-Jettorrg motend os 'rye: :r
d ;scovereT !ha'. :s reaueec to be remove. , 1 to support iork
NOTF GI* 0 w1i to be rernorM has tested negct'.e. Pr .t hos test resuit'
The foci i'; mater: is in the , reos adjacent to '.is jot are assumed
+o be Cos for C5b'stcs
. HLnD F' TItiG: Cr O'BEFe :T ASS PIPE
FLOG TILE LAD mASPC 4 1 L ,' _ W-$TE BROvAi ;
FIFE X'DRS
kiDDEt FIBEaG.1.SS TAM INSUiA ON
OATINC Oh BALI' SDE OF EXTE?OP METAi NA` PANELS
DC
LEGEND:
GENERAL NOTES:
EQUIPMENT NOTES:
CONSTRUCTION NOTES:
RE;A .'vt E.XiS'!NC UNIT HEATER DUCT
_ APL :Di,�
TO AVOID CRANE RAILS
REMOVE £XiSTING UNIT HEATER & 1 DNTROLS
REMOVE EXISTINC UNIT 4 NND
WALL '1 '=Rlv1: STAT AND
REINSTALLAT;'CN.
SHEET
JOB NO
DW(i NO,
EXISTING TO REMAIN
(4
— l
KEY PLAN
SCALE NONE
PERMIT SET
CURRENT REVISION SYMBOL
100015 -011
IM1OR
B
9- 99.1 -1M1OR
SEP 2 4 2401
o
nn r=
PERMIT C
DATE
100015 -01 COMP NO
07.31 01
ATPCTJPELBJP(RADE ES
M
•
MODIFY HVAC SYSTEM
REVISION
E RCS MODEL SHOP MACHINE
9-99 morn SHOP - PHASE AND 2
BY
KGP
KGP
411'0024-04 HARRAH
J# DLR GROUP
APPROVED DATE
i •
•
RP 07.31.01
R;YDF7OP
UNIT HEATEP
ii
REVISION
BY
---
APPROVED DATE
F i
ASFISPIEZAW
24 DIFFUSEP
250o
: k;4
-"///,',";
350 CFM
•
M /
ROC' 1
, •
4"0
700 CR
,
40 7.
APPROVED BY
24 INFFUSEP
4 \
DEPT
\
3"X 90' ELL
Ia)
.i;
1M11R M523 r!
1
di
• •a
I
11
ACCEPTABILITY
THIS DESIGN AND/OR
SPECIFICATION IS APPROVED
I
CPAWN
PENROD
CHECkED
-ENGINEER
DATE
CHECKED
APPROVED
APPROVED
_
DATE
9-27-93
< 1 i
1 '
TOP' COLLECTOR
V ) — FRONT COLLECTOR
SUBTITLE
TITL
MA L INE
1M11RIM523
REMOVAL
PLAN - HVAC DUCT
9--9MODEL SHOP — PHASE 1 AND 2
BUILDING 9-99.1
MECHANICAL MASTER COL A—C/1-4
LEGEND:
GENERAL NOTES:
I Aa3EE 7 0S PC MCA 7X
A 90.x s.irt,e) ,. tt-e• *A Tel hf beer' t:cateucteri and asbestos
coht:rirg Titer was hot fist(Arefec that •),,:a be rveired in tne
tet;s cf:jec :k lot rerr, acenage or a
C1St est.:s trIteria atjxerr. t: the ice. a.-e cOrt3:t eoeir;
Foclitors Drtrner.t otsbestos contNwg rnaterial s oioged
stsethere not ,5 requ , 3 Support
NOTE: GIVE 11 tiro) to be removed 'es tested negative. Pr4 hos test reT.Ats.
The foilowir materials r* the areas adjacent to ttm: job are assumed
to be oosit;re for asbestos_
KARS P7T ON FIBERGLASS PPE Rt!NS
2. VA-0 77 E tiSULK-Dti
3. ;1•0P - ;LE ANC 144STC 112412 4147E/BPD4A,
4. r9E DOORS
5. VI.ICk\D FlegsGiAS TLY
5. 004740 O BACFS'H ErERIOR METAL WALL Rehas
EQUIPMENT NOTES:
TORIT DUST COLLECTOR ivi,C 9 W1 HOPPER AND
SILENCER. 8" ND:" ON BAL SIDE 180C CFM @ .3"
EXTERNAL STA r.=RESSUP;- 5 — 3745 RPM,
460V / 3 PH MOTOR
CONSTRUCTION NOTES:
REMOVE TORIT DUST r'aLr- SYSTEM FROM 9-99
REMCV;: JUST COLLECTION DUCTWORK
1> - REMOVE DUC TWOPv..
REMOVE DUCTWORK AND RETAIN FOR RDNSTALLATION.
D.C.
CURRENT REV
1000
SHEET
JOR NO.
DWG NO.
KEY PLAN
SCALE NONE
PERMIT SET
SYMBOL
1M11R
100015-01
q—QC1 1 -1A/111P
11J6 2 9 ,C
PERMITCENTEH
DATE
07.31.01
COMP NO.
V REVISION
4 STPU( TURE LA8 UPGRADES
13 PROVIDE AIR OUTLET
C 9-92 MODEL SHOP - PHASE 1 AND 2
4
4100015-01
BY
KGP
DMV
DLR GROUP
APPROVED
DATE
— I.E. 11.4C
-:"
' ;
NSTPtiMEI`:iT.ATiON
h
•i HPLJ
el - AL'; e
I j
M01-1 51
7-31-00
RP 07 31 01
REVISION
APPROVED
SYMBOL
THEFT
1M6OR
JOB NO
100015-01
DATE
07..51.01
COMP NO
ACCEPTABILITY
THIS DESIGN AND/OR
SPECIFICATION IS APPROVED
APPROVED B
DEPT
DATE
AWN
K PENROD
CHECKED
ENGINEER"
CHECKED
APPROVED
APPROVED
REMOVAL
SUBTITLE
TITLE
A * *lr r .:410,11
A 30od 'citr S C tbe wort area ,71s beer :cinduc!.ea and ast,e-.:tiois
contcrieg mci discoNefet thcit i. c riolve--,1 r
...orri tris .-ef"ose. iiorloer
asbestos rnateria' *:4 :rec. P1ese contact
Decortrnert f cont3-7:rg .rioter4 is danCre:
21 t'a! is reitii to be removed tD si.4. ioi
NOTE: GYit 0 id :o be rernored has tested negate. ?raj. has test results.
The following mcterids in the cirecs adOcent to this job are assumed
to be D;s;t fcr ostestos
7. tAPC Oi FIBEVAASS PPE P0PIS
2. mAG Pp .r:
3. FLOOR TILE , tNE MASTIC (122 /frirTE/BROWN)
4. F:RE DOOPS
5- muDDET: =IFERG,ASS TANI tNSULATY.:1,1
5. COATING ON BACKSIDE OF EXTERIOR METAL WALi PANELS.
-
MECHANICAL MASTER
PIPING
(
9-9 MODEL SHOP - PHASE 1 AND 2
BUILDING 9-99.1
COL A-C/1-4
REMOVF_ HOSE 3IBBS AND PIPiNG. CAP ABOVF_
CRANE ELEVATal
REMOVE STORM LEADER OAP AND ABANLYN EYST1Nf:
4" SD IN PLACE
REMOVE CONDENSOR SUFPL AND RE
LNE'S AND !DAP AT VALVES AT NAL.. ALL PIPING
BELOW CRANE LINE TO BE REMOVr.iD
REMOVE STEAM PIPING AND VALv'ES. JNIT
HEATER TO BE RE-USED
REMOVE AL. :. SUPPLY AND RETURN
LINES NSir.T ENCLOSURE
ok 00* l
GI eiz i-vi,i)
4 20‘
SY 2 ,
KD PLAN
I PERMIT SET I
D C
LEGEND:
GENERAL NOTES:
EQUIPMENT NCTES:
CONSTRUCTION NOTES:
DWG NO
SCALE: NONE
C1_0(1 kicnn
AUG
•thmii CENI ER
R
"7)TRUCTURE LAB UPGRADES
MODIFY HvAC SYSTEM
ff. RELOCATE EQUIPMENT FO IASL
INSTALL BYPASS LOOP
_
REVISION
9-99. MODEL SHOP PHSE 2
BY
KGP
4175 KGP
J#765412—LO KGP
j#l(or o DLP '3P0UP
L
•
• r
0
150 KIP
to
APPROVED Err
DEPT.
ACCEPTABILITY
THIS DESIGN AND/OR
SPECIFICATION IS APPROVED
DATE
PRAWN
PENROD
CHECKED
FNGINEER
CHECKEb
AN
mr
2 1 ./2" UP DRY
SFIR!NKLER t-k TO DP'
SPRINKLER VALV
M01-15 I
9-13-93
SUBTITLE
TITLE
I
MATCHLIV
4" DS DN TO 6" C.I.
2" VIP.
c
v?
••#' \‘ \ -3/4" cvv
- - 3" CS
3" CR
4" DS UP TO 4" RD
MECHANICAL MASTER
PIPING
4
REMOVAL
g- -9 MODEL SHOP — PHASE 1 AND 2
BUILDING 9-99.1
COL. C—E/1-4 D.0
LEGEND:
GENERAL NOTES:
"
s/vey the or area •es teen et: ascestr_s
contort; inater oos not discovered r" the
corstracticr st •r.•s pr. Do not re-rove 1-ornage or st-At ori
ostestos nrwiter:di ad5xert • 11.7 3reO Dime Corzce. Boerg
Fockeities - -;e0ort - rient mest :ortarrg moterol - 1 dor c;ed
div:overeO tl3t is reqe D be re!roviec to 54ppr:r *y
NOTE: G*E § dI t be removed hos tested negative Pr hcs test results.
The followild rnater:zis rr the areas u to this jot ore aSSOrTler:
* tc b t),.!tive tor astes;.
1. HAP:), cr FCERGI.A.SS PIPE R%A.S
2 W' FlPE. IIISkiLANN
3. FLOOP. - ILE ANC STIC (12 11/
4. Frlw D')ORS.
5. !Air: 0E2 FIBER.SLASS TM?" INSULATO4
5. OCATING ON BACOE OE DCF_PiOR kiETk. WALL PANS.S.
EQUIPMENT NOTES:
CONSTRUCTION NOTES:
[2:2> DEMO . SPRINKLER IALIE AND CESOF:ES.
CAP L;NES AS REQUIRED
REMCvE ALL CONDENSOR SUPPLY AND TURN
L:NES
--- REMO vr AL CONDENSOR SUPPLY RETURN
UNES BELOW EXISTING VALVES 2C AFF. CAP
PIPING AS REOLRED
REMOVE ;2) COMPRESSED .AP LINES BACK TO
MAIN BRANCH AND CAP OF
40
ri \‘
U4 ' 't,e4
so 2
-‘',/ PLAN
17 E. NONE
CURRENT REVISION
1 00 1 '15 - 01
SHEET
1M61R
!OE NO.
DWG NO.
SYMBOL
100015-01
9--99 1-1M61R
Am a
PEI-vvr ‘,..EN
PERMIT SET
DATE
07.31 01
COMP NO.
M
REVISION
EIY
APPROVED
DATE
A
STRUCTURE LAB UPGRADE'=
KGP
06.30.99
B
9 -99 MODEL SHOP - PHASE 1 AND 2 J # -01
DLR GROUP
KR
07.31.01
/DC
\2
STERNVENT
SAW DJS
__EEOR
�E' Q DROP
TC FLOOR E
65C CFM
/ I I MAY CMS.:
SANDER 3r
—i 350 CFM
II
(1
f
— 4% 10.0 CFM \ {i
— 6 "m 3 HP 4-80V 3 -PHASE l
It
BAND
SAM OG OEM
I II
1
_ Et c II
I �
Ili
ii
SURFACE TABLE ! ~- ._- -
—6"0
;r - ,N1 SAM 350 CFM
1M11 M523
=1ELD FABRICATE
ON DISCHARGE 45'
r OF 2
MFG. AREA
r 36X48 LOUVER
MAN -BARS
ALL AROUND
MAN -BARS
ALL AROUND
TABLE 94 350 T M MAINTAIN CLEARANCE
ABOVE CRANE RAILS
10,000 OEM
3 HP 480V ' -PHASE
I VD VD
/
EXISTING
MRLNG
MACHINE
REVISION
BY
APPROVED
DATE
i._ = , 1 _L i i i I L
0
>00 G KI! �j -
1 L_
- -
Hub pi 0 1
r
I/
elfirzterzAw
-_/
-H
{ E
•
FYI . TiNG
> J
L
IIFF I.ISER
2.50( CFM
APPROvFD BY
11 I
MFG. AREA
ACCEPTABIL
THIS DESIGN AND /OR
SPECIFICATION IS APPROVED
DEPT.
DATE
1M10 M523
01451
DRAWN
M DITTMAR
CHECKED
'ENGINEER
T HANSON
DECKED
APPROVED
, 0UROVEC
DAT
09.09.93
09.09.93
6" 0 DROP
TO FLOOR SWEEP
usc
GROW
350 CFM
350 CFM
.FM
BA*
SAW
DRILL
PR ESS
8 "X 90' ELL
SUBTITLE
TI TLE
8 "0-
TABU
SAW �!
MINIMUM DUCT
VELOCITIES 3500 FPM
/ I
I
MECHANICAL MASTER
REL CATS
CABNE' pus - Yn.LECToe \, ( fir'
\1 /
I TORiT )UST COLLECTOR ` 1
1
`) rRON` OF COLLECTOR
I �
r1
1M10 M523
PLAN -HVAC DUCT
BUILDING 9 -99.1
I
I 0 00
I PERMIT SET I
9 -99 MODEL SHOP — PHASE 1 AND 2
COL. A -C/1 -4 D.0
LEGEND:
GENERAL NOTES:
A !IOTICKATF'_s,
A :r `. :• spy e r o+ the ,. areo * :ovc ted astest l.s
eat. ; ma'F(Ys soS TiOt 3:s_ow- -ee ;hr: re.A.> be .!ss,.ra the
car strv :Kt of - s prc e.ct ao • *e - i€ do 13IJe Y d=stat am
osbest.s , :jp:e^rt to trf a.ms ye,. % -a =se corr.t::.t Boeing
Fxir-ees Deportment ;se?st:.,s rontor'rS meter►of s i°-noged or
d=se3vefed that is recu t; ie remo*: support sr
NJTE: G113 0 > to be remcvey nos tested react ve Fro; h as test :esv1•;.
The folloEnc Toterl:ots it the oreas odjocent t: Ely's pb are assured
to be positive for asbestos:
I. HMO crmr4GS ON neERGLASS PIE RUNS
2. MA; o•PE ? &LAT,ON
F_OOR TILE AND MASTIC (12%12 MIHTE /BROM I
4 :lit DOOPS
5. MUOOEC riKS TA1:K •NSU:.ATK!.
5. COATING ON BACKSIDE )F DTER1OP METAL WALL PANELS
EQU'PMENT NOTES:
TORT DUST C' MODEL 90 VAT: LC PEF AND
SILENCER. E 'NLET ON PACK SIDE, FHT: CFM
EXTERNAL. STAT _ P 5 HP. 3745 RFY. 4 673 MOTOR.
CONSTRUCTION NOTES:
INSTALL DUST COL LEA 1O! 'S iE4! FROM SUILD NG 21 -03
liFROCUREF.) AND DE_ E =1E NS
r �� r
.O.vn D[ I n. FOR TABLE YAW, DRILL PRESS. DISC
GRINDER BANDc,AW AN: PANEL SAW EXHAUST THP
COLLECTOR AND CIRCULATE BAD INTO BU!!DING SF .■,E
MODIFY DUCTWORK FROM EXISTING UNIT HEATER
RE!NSTA'-L IJNIT HEATER !N H`7PAULIC. TEST AREA
AND RI_OCATE ASSOCIATED THERMOSTAT AND CONTROLS
PRC JIDE MANBARS IN DUCT PENETRATIONS OVER 96 SQ INCHES
WITH 1/2" STEEL BARS WELDED ON Es' CENTE!<
INSTALL RELOCATED T(RIT DUST COLLECTION SYSTEM FROM 9 -99
BUILDING
PROVIDE DUST EXHAUST FOR TABLE SAW, DRILL PRESS, DISC
GRINDER, AND BANDSAW. EXHAUST THR'J DUST
COLLECTOR AND EXHAUST TO OUTDOORS
FLOOR MOUNTED PARTICULATE COLLECTORS RELOCATED
21 -03. INSTALL AS REQUIRED.
NEW DUCTWORK.
<EY PLAN
SCALE: NONE
CURRENT REVISION SYMBOL
100015 -00
SHEET
JOB NO.
DWG NO.
1
100015 -00
A
9-99-1M10
FROM
DATE
07.31.01
COMP NO
2
2
REVISION
STRUCTURE LAB UPGRADES
MODIFY HVAC SYSTEM
RCS ND :DEL SHOP MACHINE
9 -99 MODEL SHOP - PHASE 1 AND 2
TRANSKQRTATICN AISLE
KGP
J# 7 D024 -04 HARRAH
J4100015 -01 DLR GROUP
8'i
KGP
MFG. AREA
H
j MS MS Ms MS MS
•
r j:3f L
(� U
10 I c4°in
i
14.7; MS MS MS
mo
2
O
r --
MS MS MS MS
- - --
MS MS MS MS
TRANSPORTATION AISLE
:*1
H
0
- 24 i 5 R
25 LEM t
- -4 - --
- 4- .... ._
APPROVED BY
MFG. AREA
26x14
DEPT.
ACCEPTABILITY
THIS DESIGN AND/ ')R
SPECIFICATION IS APPROVED
24'• D*PJSEP
-25+00 C FM
TRANSPORTATION AISLE
DATE
APPROVED
A
DRAWN DATE
M. DITTMAR 09.09.93
CHEC
N I
T HANSON 09.09.93
CHECKE6
•
- t
A401-I5I
TITLE
SUBTITLE
I PERMIT SET I
MECHANICAL MASTER
INr
LEG ND:
GENERAL NOTES:
PLAN-HVAC DUCT
g — :9 MODEL SHOP — PHASE 1 AND 2
BUILDING 9 -99.1
COL. A —C/1 -4
• 4.. - - /6 NORCICA Ot■
A : )C ell St • :'4t s7r. - yet) Gen - onl,.ctee aM osbest
contxs -; A*►a'mra L= xt trsc: -ee >'.4.Q3vet r tht
lcst et :f '* s ;,r:lect nc. 't"tarrF 33mofye ,,r .stsrD a^y
ost:-strs mc:?•: *t Vic. • ►e a l ee Please : :rtott Boeing
F3: its s _£1 ':^P? ;f Cst 5t:.5 t'ar'.'?- r•y moter!j i3r�e: �!
e *SC0v°e' -T ' ^ct •S regjr `.: be ''y'^ ✓ied to aapporto ucf
NOTE: GAS 0 k :. to E renovec has taste,! regctive Pre} has test resits.
The foeswing r" teridS t^ ,r,c , Yeas od ocer• : this ob are assumed
to be positive 'Of csbest's:
1. eAPD E"T!NGS 01'` ' F'E?:4ASS PIPE PIAS
2. ',AG P ='E INS - LLT .
RCIOP TIE 4!C. ST;r (12 veTE/W:foi,
4. cPE DOCPS
5. MLD^1E^. FIBE?c�SS r*. °NSI;LAT031-,
5. COItT' +O Ch 9ACwSITE OF E.POP SAL *A . PANELS_
EQUIPMENT NOTES:
CONSTRUCTION NOTES:
APPROXIMATE LOC=:TiI_''J -. SHOWN. NS RE_C;CATED
BRANCH DUCT, COORDINATE W! T r EX,STING PIPING
MAINS ANA;' CLEARANCE'S REGU RED B'1 5 TON CRANE.
2-
�pp1
/ fir'
D.0
SHEET
JOB NO.
DWG NO .
KEY PLAN
SCALE: NONE
CURRENT REVISION TSYMBOL
1 00015 -00
1M11
100015 -00
9- 99 -1M11
•
H .
—∎ ,A
RECe4'. C
CCTVor TI)b(V A
AUr
DATE
C OMA' NO.
- nl
07 '' 01
A STRUCTURE LAB UPGRADE
B PROVIDE AIR OUTLET
P.EiP:ATM
CABINET DUST TOLLEF:TCP
REVISION
9 -99 MODEL SHOP - PHASE 1 AND 2
I.E. 11.53
I �1
—
'E STAE
TOKEN
DUP:_EX A •R OUTLET
48 AFF
I
MA3 Da
SANVEa 3C
BA(`
SAW
— 4"
_ -
DUPLEX AIP OUTLET
48" AP
TABLE SAW
'ANES SAW
DUPLEX AIR OUTLET
48' AFF
■
J #702096 -00
J#100015 -01
2 -1/2" UP DRY
SPRINKLER VALVE
(E) 2" A
BY
KGP
DMV
DLR GROUP
APPROVED
KP
DATE
06.30.99
07.31.00
07.31.01
( M
MFG. AREA
[EXISTING AREA
1 6018 OF 6494 Sh
33 OCCUP
200 SF/ OCCUPANT
.PANT
SD
- 3' • DS DN TO 4 C.i.
POC
DUPLEX AIR DUTLET�
48" AFF
(E) 1 X4 „ S _ V
(E) 1" COND --\\
RUN AIR LINE
96" AFF
TIGHT TO
DUPLEX Al
48" AFT
MIWNG
MA)4WE
DUPLEX AIR OUTLET
48' VT
REVISION
SURFACE TABLE
- - - - -- DUPLEX AIR OUTLET
48 AFF
GRILL
PRESS
..L
3 „ OS UP - ' RD
iIl
L
F
I.E. 11.40
1" COND
All Ac
�I+
BY
l
APPROVED
t
ICI
DATE
/ UH
1M60 M523
FIN FLR ELEV 15.5'
2" A—
500
KIP'
r --
o �—
b
_ _ f _
,
elfinsE /NG
ill
C> 11 :
•
A1IAS
APPROVED BY
ACCEPTABILITY
THIS DESIGN AND /OR
SPECIFICAT'nN :s APPROVED
DEPT
MFG. AREA
EXIST!1`11i MFG. SRi A
5992 OF 6580 S:
33 OCCUPANT':. A I
200
M01 -151
DATE
DRAWN
M. DITTMAR
CHECKED
ENGINEER
T. HANSON
CHECKED
ArPROq
A,nnonVEt
'
CIAMMT
DUPLEX AIR OUTLET
48' AFF
1/2" AIR TO DRY
SPRINKLER VALVE
DUPLEX AIR OUTLET
48" AFF
(E) 2" A
DATE
09.09.93
09 09.93
TAB,`
SAW
BAND
SAW
PRESS
SUBTITLE
TITLE
MECHANICAL MASTER
RELOCATED
CABINET DUST MLLECON
I PERMIT SET I
PIPING
9 -19 MODEL SHOP - PHASE 1 AND 2
BUILDING 9 -99.1
COL. A -C /1 -4
LEGEND:
GENERAL NOTES:
A '.itf 3re^_ "-3S Deer '.0n&: 3$ "06
CCrItO.Tr1 'refer,/ •ss '?Ot fiscyvere.t s:4ATC cloctoel c tare
c nstr _ '.^s DrC :: ur3 "5: !�'r IE � }r JE 35=.A:1%. any
lroestCS :•.tr:?rt P. -.2, c ts. Boers;
3G`
:vr't41f:f i mA7'.G!ool '$
2 that es 'eairei t ae rer*?D4'1 'S su.^VOrt ■:,r+.
NOTt: C 6 • to be , ernoved nos tested negotive Pro} hos test rest... s.
ne fi!osin -hater = t•,.e areas odjx t to this pt ore assume
to be positive `or ostest•i_
I HARD F!" 'Au.;S ) F, IERG,/SSS PIPE RA.NlS
2. wAG INSULATION
3. y TILE MD MASTIC (12%12' iffTE /EROI V
4. P E Dtf/RS
1luo: FieEPo .ss -:NM '►.'SULADON
5. C3L 1' O Gtr ?ACKSff_ OF E('EzCP META_ N.Ai, PANELS.
EQLIPMENT NOTES:
CONSTRUCTION NOTES:
FPOVIDE STANDARE Lo_,PLEX AIR RECEPTACLE
SEE DETAIL 'x=23
PP0J DE 3" STORM DRAWN
CUT A "Ji RA AS REOUIRED
PROVICE STJPai SEA 1'CE AND CONNECT TO EXISTING
PROMDE SEAM PIPIND AND AC ,ESCRIES FOF. PE,NSTALLATIOI.
OF UNIT HEATER. FE'L SE EXISTING VALVES
01'4
n c
' A
1 3'
b 10 Z
•
5
KEY PLAN
SCALE: NONE
C URRENT REVISION SYMBOL
100r15 - -00
SHEET
1M60
!DB NO
1 0001 5 -00
DWG NO. _..
9- 99 -1M60
•
� T Y nFEitV� W'( A
1 -1! „. 001
ENTER
DATE
O 31.01
COMP NO.
A
f:5
STPUr.iuRE LAB UPGRADES
MODIFY HVAC SYSTEM
RELOCATE EOUIP TO IASL
INSTALL BYPASS LOOP
REVISION
2-99 MODEL SHOP - PH Ai i AND 2
'- "r
-/
DUPLEX A P CUTLET
48 AFF
TRANSPORTATION AISLE
475 KGP
J#7€5412-LO KGP
J#5;0015-01 DL P GROUP
BY APPROVE
KGP
KGP
EJC
EJC
RP
DATE
06.30.99
03.09.95
11 07.9f
07.31.01
/M
,
1 7 =
•
, I
I •
714
4-1 "."
H
I
—H
M Ns 1 MS 1
i MS
Ll 1,
1
I-- I
11.:•':
1 kit
L
REASION
MS MS kl
1 Mt 1 ms I Mt:
H 4,
L
BY
1 1 ;
APPROVED
DATE
• '
I
I i
I
• r t
•
I j
I I
1
1 1 I
• ;
L II ; 1 1 ; ;
TRANSPORTATION AISLE TRANSPORTATION AISLE
H
1
,_, 0
Arzter.va
A
H
MACHINF
Lii
M I-- I 5
; P
'q STE 1 ' v
C>
MFG. AREA
ACCEPTABILITY
THIS DESIGN AND/OR
SPECIFICATION IS APPROVED
APPROVED BY
DEPT.
(E) 2"
DRAwN DATE
M DITTMAR 09 09 93
cHEcKE6
ENGINEER
DATE T HANSON
CHCKED
APPROVEb
APPROVED
1
09.09.93
t
Er
SUBTITLE
TITLE
MECHANICAL MASTER
MA
1 PERMIT SET 1
PIPING
9--A MODEL SHOP — PHASE 1 AND 2
BUILDING 9-99.1
COL. A—C/1-4
LE3END:
GENERAL NOTES:
• ASEESTX
A pod the Waro T NIS beer. "andu.:tet bstest)s
contairto; rflter sas •,t coi t be r rol*c #
COnit tr pr.oject rct damage or *stun: or/
ost;eST :r • oe!:::er PleaSe cont.xt %erg
70c; lies De " :sbest rioterd s .1-7ed , 7A"
rece..,red t be terr-ciel t: support
NOTE GING 0 *041 to be rerno.eci has testes nertme :" hos ter resot
folovirg "natet"s ir tt; 5-e3s odjocer." to this yob or as9Jmed
to be posftnie for oshest)s:
1. NAF,C FITTINGS ON FIBERGLASS PIPE RU'S
2. YA-3 PIK ?UT(-
3 , FLOOR TILE JC kosno 212 viTE/Brkv.w.
RPE DOOPS
5_ isuDDE: R8E TAN.- =NSULATOi
5. COAThr, ON BACKSIDE r:ri E META_ ALL. PANELS.
EQUIPMENT NOTES:
CONSTRUCTION NOTES:
PEOV1DE STANDAR i jTHLEX AF P,ECEPTL'CLE
D,C
SHEET
JOB NO.
DWG NO.
KEY PLAN
SCALE NONE
CURRENT REVISION 1 LIMBOL
100015
1M61
100015-00
0-00-1LAR1
DATE
COMP NO.
0731.01
re'1e 3 L"kc S
illecreventv 5':wrr•; Ye oagranwil 2'•: Gad Ordkoltie tine ?eve i arr'ager-*ert :t sin -tees and equp°nent. a eeD- wee spiecificary
cirnw s:nat: Qs' "!•e: Forty; :,D-s+ an! 91: :'w r s.ans a harems,: sews sae. capacity. aptrairmate ;ocateor;
W -neeti's- stic . nter re:tont* of ovule • :v 1 tc J19ofter. t -t rot tie eioct (let+' , air anrainge hen
A ?As rive ", . srowrgs are cal �� scale n n•a! ptinbie !. lido neces-sary offsets. fittr.gs. er.d tee >riei
bowie •entr -:' nerstrantion. vet- ?"-cal, anti Oct -. :4 nfircivirqs. st'tcr enact iocatiens. measurements. revels. etc.: the s'te
ar- 'range systems ac : are at er addrt,oe:a exoeese to *_^_: avid knish fttie±gs, offsets_ and ss.:ries as require
iE rroi Sep;: r: _, c1•Ydiir :te and erntegrate `^e naus elements of rrie.hanicd systems, materials. and equprtnerit Can Vly
wile. the teito4' _ regarean.rrts
1. Wee ma rrt'rrg - 9 is are not jet :tic.' :r dihersiaraed, nstaG systems, rate- r`ars. and equpment to ptz .ide the mailman
heater
2 C,s •�� _'e :vi r-e :noon of mechanic:. systems aiti extef -x umdergrc -.rid and overhead unities c'd services Comply mite
reg_ +'r-•erlts of eove-nsng regsee .or s f•anchised service companies and controlling ogencies. Provide required Corvine: -t r for e^ :r
seance
3. t-star meeho icd eanyeneet t'_c `tote se'i: erg, reietercree and rxior or r?Yen!trent of e4.1pment components. As much
Cs crac'.'ca, cOnredt equt^t .: ease of 3 sccrne:t •C. with ^lirtirure rf inter -ence with ether installations.
STORM Di NOTES
A. Provide cast -ear - _b'?ss pipe and fittings wit ieea +. -anty. Type 301, Stai_n ess -Steer Couplings: AS'►d A 666 Type 301,
stainless -stee. 5t: stemless -steel bands, ara sleeve_
1. Instdi cost -nor. sag P.P. ng according to asPr's 'Cost iron Soi Pipe and Fittings Handbook.' 31apter IV, 'Instdlotion of Cost Iron
Soi Pipe anz
2 Charges ' dee_t c' for storm cipng using epo'opriate branches. herds, and Icng -sweep bends. Do not change direction of fow
more :ear 90 deg'ees. Use proper size of standard increasers and reces ers if pipes of different sizes are connected Redunrg
size of c'crcce aping it drect on c` flow is prohibited_
3. Horizorta Steve 2rai'.age Piping- 2 percent downward it direction of flow.
B. Do not enclose, cove'. or put piping into operation ern; it is inspected and approved by authorities having jurisdiction..
1_ Hubiess Joints, Woke with rubber gasket and sleeve or clomp.
C. Support devices. nsta °I the 'o!:r.wina
1. Ve ^.rcc Piping- MS` Type 8 or Type 42. :lamps
2. Indieioec:, Strciget, - +orizontdl Piping Rums Accordinc t: the following:
e. 1G0 Feet 30 mn and Less: MSS `re• cdiustat e, steel clevis hangers.
b. Longer T ^an 1C: Feet 30 m): MSS Type t3, cdjustaale roller hangers.
D. Pod diameter moo •e 'educed I size for double -rod - .angers, with 3/8 -inch (10 -mm) minimum rods.
E. Connect interior stn"' drainage piping to existing storm droinoge piping.
E Connect storm Craircge ciping to roof drains and storm drainage specialties
COMPREcc,r' - AIR PIPING
A. Provide Low- Press_'e, Compressed -Air Piping: ASME B31.9, "Bui ding Services Piping," for piping operating at pressure of 125 psiq
'860 kPo) or less iced at temperature of 200 deg F (93.3 deg C; or less.
B. Hose, .Icmcs, :-: :oupergs: Provide compatible hese hose clomps, and hose couplings. suitable for compressed -air service, of
nominal diamete' are' rated for 300 -psig (2C 7 0 -kPa) minimum working pressure, except where otherwise indicated.
1. Quick Conre :t,'C iscoer.ect Hose :.ou0!ings: Or e -way. automatic snutoff, cross body, wit' 0 -ring or gasket seal and
stoirless -sr° ''c?• el- plated steel operating parts. Select socket end with threaded 'let that is considered the fixed end and
has one -way vd!ve.
a. Plug End: Flow- se ^sor bleeder. check -valve type, with serrated outlet for nose.
2. Hose: reinforced, male- or double - braid, neoprene- covered hose for compressed -air service.
3 Hose Clamps Staff^ ess steer, clomps. bands, or wire.
4 2 -inch NPS (DN5C1 and Sma'le`: Galvanized steel pipe; galvanized, threaded.
C. Drawings indicate valve toles to be used. Where specific valve types are not indicated, the following requirements apply.
1 Shuts` Duty- Use :en valves.
2. Throttling Dity ess globe valves.
3. Compressed -Air Sur: y to Equipment: Locking- hondle, safety- exhaust boll valves.
D. Install air and drain pipi_; with ore percent slope downward in direction of airflow.
E. Instal' eccentric reducers where pipe is reduced in size in direction of airflow, with bottoms of both pipes and reducer flush.
F. Connect branch air oioirg to mains from top of main. Frovide drain leg and drain trap at end of each main, branch, and !ow
point in piping.
G. Install supports and ancr:^s 12 feet (3.6 m) horizontal and 15 feet (4.5 m) vertical.
H. Instal pip era next to equipment and accessories to allow service and maintenance.
I. Connect air pipi =c to equipment and accessories with unions and shutoff valves. Insta. with strainers where indicated.
METAL DUCTS
PART 1 - GENERAL
1.1 Duct system desia'. as irdicated, has been used to select size and type of air - moving and - distribution equipment and ether air
system components. Changes to layout or configuration of duct system must be specifically approved in writing by Architect.
Accompany requests for iovout modifications with celcuictions showing that proposed ' ayout will provide original design results without
increasing system total pressure.
1.2 SHEET METAL MATERIALS
A. Comply with SMACNA's "HVAC Duct Construction Standards - -Metal and Flexible" for acceptable materials. material thicknesses, and
duct construction methods, unless otherwise indicated. Sheet metal materials shall be free of pitting, seam marks, roller marks, stairs,
discolorations, and other imperfections.
B. Galvanized Sheet Steel: Lock - forming quality, complying with ASTM A 653/A 653M and having G60 (Z180) coating designation; ducts
shall have mill- ph•asphatized finish for surfaces exposed to view.
1.3 HANGERS AND SUPPORTS
A. Building Attachmerts: Structural -steel fasteners appropriat:= for construction materials to which hangers are being attached.
B. Hanger Materia's: Gclvcnized sheet steel or threaded stee' rod.
C. Duct Attachments: Sheet metal screws, blind rivets, or self- tapping metal screws; compatible with duct materials.
D. Fabricated buildouts (meta' hat sections) Or other buildout means are optional; when used, secure buildouts to duct walls with bolts,
screws. rivets, or welds.
1.4 ROUND DUCT AND FITTING FABRICATION
A. Diameter as app.ed tc flat ducts in this Article is the diameter of a round duct with a circumference equal to the perimeter of
giver size of flat -oval duct.
F. Pound Ducts: Faoricate supply ducts of galvanized steel according to SMACNA's "HVAC Duct Construction Standards - -Metal and
Flexible. Riveted and Soldered.
C. 90- Degree Tees and Laterals and Conical Tees: Fabricate to comply with SMACNA's "HVAC Duct Construction Standards - -Metal and
Flexible," with metal thicknesses specified for longitudinal -seam straight ducts.
PART 2 - EXECUTION
2.1 DUTT APPLICATIONS
A. Static- Pressure Classes: Unless otherwise indicated, construct ducts according to the following:
1. Supp'y Ducts: 1 -inch wg (250 Pa) 4nsert pressure class>.
2. Exhaust Ducts (Ne ;ative Pressure): SEE SAWDUST COLLECTOR DUCT
B. All ducts shall be galvanized steel.
PART 3 - EXECUTION
3.1 DUCT INSTALLATION
A. Construct and Install ducts according to SMACNA's "HVAC Duct Construction Standards - -Metal and Flexible," unless otherwise
indicated.
B. Install round ducts in lengths not less than 12 feet (3.7 m) unless interrupted by fittings.
C. Install ducts with fewest possible joints.
D. Install fabricated fittirgs for changes in directions, size, and shape and for connections.
E. Install ducts, unless otherwise indicated, vertically and horizontally and parallel and perpendicular to building lines; avoid diagonal runs.
F. Install ducts close to wolfs, overhead construction. columns, ari other structural and permanent enclosure elements of building
G. Coordinate layout with suspended ceiling, fire- and smoke -cont of dampers, lighting 'payouts. and similar finished work
H. Electrical Coordination: Route ducts to ovoid passing through transformer vaults and electrical equipment spaces and enclosures and
avoid passing over any e'ectricol panels.
I. !nFteli ducts w'tr hangers and braces desicned to withstand, without damage to equipment, seismic force required by applicable
building codes. Refer to •..MAGNA "Seismic Pestroint Manner nonielinps for Mechanical Systems.'
J, Protect duct interiors from the elements and foreign materials until building is enclosed. Follow SMACNA's "Duct Cleanliness for New
Construction "
3.2 HANGING AND CUPPORTING
A Support horizontal ducts *thin 24 inches (60C mm) of each elbow and within 48 inches (1200 mm) of each branch intersection.
B. Install upper attoruments to structures with an allowable load not exceeding one - fourth of failure (proof -test) load.
FIRE- SUP= PEfSION SPRINKLERS
PAR' 1 - GENES.
11. 9,1AMAIR •
A Prom.de •e' c+6e ent-sierneressne, soriiers, educing pot , yal*S 4 it it,es acrd automatic sprinklers as reQres f*' NI TA to serve
Sat. M311,10 -•..r Are,: and Mort. Minu'xbseirq Awe's Existing wet scer;w"er .dives
6. Pro+wde err fire su*ctesss,o*1 sceireaexs fndudi.g ac°eg. valuers. specialties, atonnotrc sprinkees. or carrapressc.. and accessories
Demo e. ash er y Nort o.i n Dr , Srr ► v s tie Esterri new ar y sprirdrier the tc re-x ate? air, Sao.,.. st note ce at Norte Side c•
8uidin3 and ^ew 4 391Tel Saoa.st 0doctor st Soute Side of Binding.
C. Division 16 relented t: novae any modifications to "Fie Alarm Systems" for drown dewces.
D. Provide Poor- : Pears Requrea foe Fre Marshall Pewse. Documents. indudkn; dra.r ;s, cdcutatans.
prepared occarding t: 474 1• for obtaining app -oval horn authorities having jur.sartdn
E. Design sprinkles on: *tar. approval from authorities having jnri54ictiorr.
F. Design sprinkler pipir; according to the 'allowing and obtain approval from authorities having jurisdiction
1 Include tru pence' many..^ of safety for decd ie 'vetee flow and pressure
2. I nclude ;a tf sugh water - serv p ri valves. a d bac.if4cr preventers
3. Sprinkle- netaipc' _ Hczard Clossfcenons: As foticws
a Shop A. eos Sr disary 'ozar Group 2
4. minimum Density 'x Auto etic- Sprinkler Piperg Design As fot'or<_
a. Ordinary HOz:•?, Group 2 Occupancy 0.20 gp!n over 1500 -so ft area
G. Components Cr a Installation. Capable of producing piping systems with 175 -prig ('200 -kPa) minimum worming- pressure rating,
unless otherwise inc rated.
1.2 SUBMITTALS
A_ Product Date: For the following:
1. Pipe and `tti^a mote'iels and methods of joining for sprinkler piping
2. Pipe hangers :nd supports.
Pipir. , seismic 'estra:nts.
4. Valves• irciud " speciarty valves, accessories, and devices.
5. Alarm devices Include electrical data.
E. Sprinkiers esc tchecrs, and guards include sprinkler flow charocteristics. mourning, finish, and other pertinent data.
B. Fire - Hydras• Flow Test Data will be provided by Owner
C. Approved Seeekler Piping Drawings: Working pions, prepared occording to NFPA 13, that have been approved by authorities
having jurisd:ctior. Include hydraulic calculations, if applicable.
D. Field Test Reports and iertifi.ctes. Indicate and interpret test results ne compliance with performance requirements and as
described ir 'lFF: 13. Include " ontrector's Material and Test Certificate for Aboveground Piping" and "Contractor's Material and
Test Certifc :te Undergrourd Pipi ^.g."
E. Maintenance Dot: For each type cf sprinkler specialty to include ie maintenance manuals specified in Division 1.
1.3 QUALITY ASSJPANCE
A. Installer Gualificc" ons: An experienced installer Who hos designed and instaliea ire - suppression piping similar to that indicated
for this Protect cad obtained design approval and inspection approval from authorities having jurisdiction.
B. Engineerir: Pesp : ^sibility. Preparation of working plans. calculations, and field test reports by o qualified professional engineer.
Bose calculation; on results of fire - hydrant flow test.
C. Manufacturer Qua 'ications: Firms whose equipment, specialties. and accessories ore listed by product name and manufacturer in
UL's "Fire Protection Equipment Directory" and FM's "Fire Protection Approval Guide" and that comply with other requirements
indicated.
D. Sprinkier Components: Listing /approval stamp, label. or other marking by a testing agency accectable tc authorities having
jurisdiction.
E. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, Article 100, by o testing agency
acceptable to a having jurisdiction.
F. NFPA. Standards: Equipment, piping, specialties. accessories, installation, and testing complying with the following:
1. NFPA 1 3, "Installation of Sprinkler Systems.'
PART 2 - PRODUCTS
2.1 MANUFACTLIPEPS
A. Available Marutc:turers: Subject to compliance with requirements, manufact 'ers offering products that may be incorporated
into the Work include, but are not limaed to, the following:
1. Specialty Valves and Devices:
a. Badger Fire Protection, inc.
b. Central Sp-inkier Corp.
c. Firematic .,prinkler Devices, Inc
d. Globe lire Sprinkler Corp.
e. Grinned Crc.
f. Reliable Ac:omatic Sprinkler Co., Inc.
g. Star Sprir.i er Corp.
h. Viking Cor :.
2. Water-flow Iriicators and Supervisory Switches:
a. Gamewell _o.
b. Grinneil Cc -p.
c. Pittway Con.; System Sensor Div.
d. Potter Ele:tric Signal Co.
e. Reliable A_tomatic Sprinkler Co., Inc
f. Viking Car_.
g. Watts Industries, Inc.; Water Products Div.
3. Sprinkler, Drc n and Alarm Test Fittings:
a. Central Sprinkler Corp.
b. Fire -End cnd Croker Corp.
c. Grirnell Co'p.
d. Victaulic _. of America.
4. Sprinkler, Brc- oh -Line Test Fittings:
a. Elkhart Brass Mfg. Co., Inc.
b. Fire -End ord Croker Corp.
c. Smith Industries, Inc.; Potter - Roemer Div.
5. Sprinkler. nsGector's Test Fittings:
a. Fire -End and Croker Corp.
b. G/ ;nno Inc.
c. Triple R S:eciolty of Ajax, Inc.
7. Sprinklers:
a. Ba Fire Protection, Inc.
b. Central S :. inkier Corp.
C. Firematic .prirkler Devices, Inc.
d. Globe Fire Sprinkler Corp.
e. Gri Carp.
f. Rel iable A tomat;c Sprinkler Co., Inc.
g. Star Spnn.ler Corp.
h. Viking Coro.
MOi1I
AC''CEPTABI LITY
THIS DESIGN AND /OR
SPECIFICATION IS APPROVED
APPROVED BY
DEPT
and material specificotions
DATE
DRAWN DATE
WTW - DLR GROUP 07 17.2001
.
ENGINEEP
RP
CHECKEb
A N
e. InlOnED
07.17.2001
SUBTITLE
TITLE
FIRE SUPPR 3 RtN1'. gS CONT_NVEE
23 PP(
A zone' AMA "51 t‘.s?'- line -point !11:e et- cement- miartar teiAng and seal coat aco rd nc 'a NAVA :104 tndude
to b.!r 9 t. - acs f . t �►111f11A ti * `
8. Steil Pipe s.°.'t1 d t 3` a5t. -3;dt -1 tnrct gt! 5-1 fDN •251 saes and NFPA '3 spec-fit: at tt' ckness tar 6-wich (ON ?SO!
through ref" :Ai 250 sizes wine eeicnr• ends. anal planned ter ccred rave yes
C., Stee Pipe t ry A "35. t!ireadable blocs are °Oka` aed `a use -..:•.d pints.
PART 3 -- EXECU "k3N
3.1 PIPING APPLY'') S, SEVERAL
A Do not use 'e; ;c<r is for gdvan:zed -steel p pe
8. Flanges, Ile-;e fittings. ,.nnor:s, nipples. and transition. and spec' fittings wee T rish and pressure
rct.ngs scn e as or higher than system's pressure rating moy ow .sed .n at-over-noel oppixat.ons, unless
ot herwise ':'toted
3.2 JOINT CONST" - ,_nON
A. Threaded -: rots Comps} . :t� !IPA 13 foe site th. :kness and treads Do not S'esd pipe serener
than NPS = 'DN 20O wear wa thickness les, than Schedule 40 ;,^'ass approvers by aithortes na.ing
jurisdret ar :rd threads ;`e the :,.ea !b v a ring gage ant :cv' ;'y w':^ *SUE 91.2C
B. Grooved Jets Assemble joints with fi=sted coupling and gasket. bncant. one baits.
1. Ductae - ' -n Pipe. Rodx,s - cot - groove ends of piping Use grooved - end f'tr+gs and grooved end - pipe
couplit:.
2. Dry -Piny Systems Use fittings ana gaskets listed for dry-pipe service.
3.3 PIPING INSTAL-'10N
A. Refer to D.• s:on 15 Section "Basic Mechanical Mcter Pis :nd Methods" for :,asrc piping instcnIction.
B. Locations Arrangements: Drawing plans, schematics, and diagrams indicate general ;xenon ono
arrongemer• of piping. install rioing as indicated as far as aracUta.
1. Deviation: from approved working plans for p•ci ^g 'equ'e writer. app'ovol from authorities havinc
jurisdiction ee written approva' with Arcnitect cefore ;evicting from =roved wVr,ng plans.
C. Install - Ins; = :toes Test Canrections" in sprinieer system c pirc, complete with shutoff .^lie sizes and
located ac :t'ding tc NFPA 13.
D. install sprier. e' piping with drains for compete system drainage.
E. Install spur- er zone oar :rol valves, test assemblies, and wain rrse'> aoiecent `^ standpipes her
sprinkler p: -; is conrected to standpipes
F. Install drair .:eves standpipes.
G. Install alarm :evices nn piping systems.
H. Hangers ar ::epee ts: =amply with " :F 11 fcr ^crier materials
1. :rstal! s:.- .k'.er syste" piping according to NFP" 1_T
I. Earthquake iz-ne_tior. install piping according t.. NFPA 17 to arotect fro^ ee _nqua•o .image.
J. Install pres_e_ gages or: riser or feed main, „tt each sprinkier test oonr:_ :or. and it t_„ c,f ec :`•
standpipe. -:ude pressure gages with connection not less 'ne^ 'vPS 1/4 (DN 8`• aril wite soft metal
seated glare .live. arranged for draining eipe oetween gage and ..dye- Install a.ge_ t- remit remove
and instal where they will not be s'•uject tc freezing.
K. Drain dr. -c se sprinkler piping.
L. Pressur ze c^ j check dry - pipe r,... it : :r system piping.
M. Fill wet- stc-dr. re :vain u:p:,ig with water.
N. Fill wet -pipe ssrink system piping with water
3.4 SPRINKLER AF= _,AT,'CNS
A Drawings ir: :ate sprikier types to be used. Where specific types are not indicated. use the following
sprinkler types
1. Rooms '5• Ceilings: Upright sprinkles.
2. Rooms .r to Suspended : eilings: =endent sprinkle
3. Wall Mot_ Sidewall sprinklers
4. Sprinkler ° nishes:
a. .Jprcrr Pendent, and Sidewoil Sprinklers: Chrome piater in finished ;paces exposed to view; rouge.
bror:e in unfinished spaces not exposed to view; wax oated where exposed to acids, chemicals, or other
corn: fumes.
b. Conce:ed Sprinklers: Rough brass, with fcctory- painted white cover plate
3 5 CONNECTIONS
A. Drawings .rsicate general arrangement of piping. fittings and specialties.
B. Connect dorm devices to fire alarm.
3.6 LABELING ANC IDEN IFiCATiON
A. Install lab dine and p pe markers on equipment and piping according to reauirements in NFPA 13 and ir
Division 15 Section "Mechanical Identification."
3.7 FIELD QUALITY CGeTROL
A. Perform the following field tests and inspectiors and prepare test reports:
1. Leak Test: After installation, charge system and test for leaks. Repair leaks and retest until no leaks
exist.
2. Test and adjust controls and safeties. Replace damaged and malfunctioning controls and equipment.
3. Flush, test, and inspect sprinkler systems according to NFPA 1 13, "Systems Acceptance" Chapter.
B. Report tent results promptly and in writing to Architect and author,ties having jurisdiction.
3.8 CLEANiNG ANE PROTECTION
A. Clean dirt and debris from new sprinklers
3.9 DFMONSTRATiCN
A. Engage a factory- authorized service representative to train Owner's maintenance pr sonnei to adjust,
operate, and maintain specialty , alves. END OF SECTION 13915
MECHANICAL MASTER
r ia- PERMIT SET
i
SPECIFICATIONS
- -( ;9 MODEL SHOP - PHASE 1 AND 2
BUILDING 9 -99.1
COL. A -C/1 -4 D.C.
CURRENT REVISION
100015 - - 00
SHEET
JOB NO.
DWG NO
SYMBOL
M521
100015 -00
9- 99 -M521
REC
Cr rV E
nar
l'ERMI T i :Es 7 c
"I
DATE
07. 31.01
COMP NO.
00
rM
REVISION
BY
APPROVED
DATE
REASION
;vM
BY
APPROVED
DATE
-1w DUST CCE.LECT:C i SYSTEM.
rsRT 1 GENEc
1' RELATED DOCUMENTS
A Drawings ar.: 3e^er7 pros :r!s of tie Centro::. Genera! anti S: ereentary n onclwtxar9s and
Division • Spec `":agar 5e :. apg+fl "o "niis Se c tko?+.
1._2 GENERA. SCOPE OF 1NC11
Relocate X -t et rortn side :' 9 -93 to loin
B. Retccote X-2 (frorn another Boeng facitty, and rstaM at south side cf 9 -99 BuiSmg
'.3 OUAJTY ASSJP& OE
A The dk.st collect s,sterr :rd components herein described are the bars of dessgn. These systems are being
:etee 'nano another 9,e'- r : cj r A uperade.s. modifitat -YS and/or fro' decision of any
r recited. to this syster w' be determined by Owner 'Er gneer only
PART 2 PROOJC'S
2.1 DUST Ca.LE c TOR
A. Dust :,oliecto- ; ?C -1 )
1. Tcrit Mode. 9C
0. Housing of 14 gauge hot -oiled steel supported by structure' steel base with legs
b. Cty. (1) 55 gal,on dust storage drums complete with flex hose and drum adopters
e. ^ccess doors n f, ter 'nxising are gasketed with 1 4 - turn knobs
d. Expos ion doe - ie 'Titer ^rousing
e. Heovy duty cotter, sotee" filters. with c f1ter pocket scoring minimum of 1 -1/2 " 99
e`*:c ency
f Fite- ^"^•cures shall have meta: insert separators to prevent collapse of filters and loss of the effective
filter area
g. Fot shaker fingers at tone bottom of the filter modules prevent adjoining pockets from touch;na one
another and bicr•hng ,"
`. 7 actory mounte.d end wired control panel with mocnetic starter are overload relays for blower
motor with siegie point connections, NEMA 4 enclosure UL label on entire panel. UL listen components alone
'inacceetoble
i. Al mechanical and elect'•_0l systems weatherized for outdoor installation
j. Belt drive heavy duty exriaust fan shall be AMCA -C, non - sparking type, dynamically balanced
k. Blower licensed and hear the AMCA seal and be tested ie accordance with AMCA Standard 21 0
I. Bearings are roted for minimum 75.000 hours average life and ore external to the airstreom
*dote. UMC Code requires interlocking all woodworking machinery with dust collector to start fan, start /stop
station to work independently
B. Dust Collector ( DC -2 )
;. "Stem.vent" DEH 515 -4
o. Housing cf 14 gauge hot rolled steel supported by structural steel base with legs
b. )ty. (4) 55 gallon dust storage drum(s) complete with flex hose and drum adapters
c. Access doors in filtf- housing are gasketed with 4" turn knobs
d. Explosion door it filter housing
e. Heavy duty cotton sateen filters, with = f' ter pocket spacing minimum of 1 -1/2 ", 99
efficiency
f. Flit ?" moaules shall have metal irsert separators to prevent collapse of filters and loss of the effective
filter area
g. Fie: shaker fingers at the bottom of the filter modules prevent adjoining pockets from touching one
another and blanking off
h. Factory mounted and wired control pone! witn magnetic starter end overload relays for blower and shaker
motor for single point connections. NEMA 4 enclosure, UL label on entire panel, UL listed components alone
unacceptable
i. Solid state adjustable controller octuates shaker at each fan shutdown (15 second delay) and continues for
2 to 180 seconds
j. Remote mounted start /stop station
k. All mechanical and electrical systems weatherized for outdoor installation
I. Belt drive heavy duty exhaust fan shall be AMCA -C, nor - sparking type, dynamically balanced
m. Blower licensed and bear the AMCA seal and be tested in accordance with AMCA Standard 210
n. Bearings are rated for minimum 75,000 hours average life and are external to the airstream
"Note UMC Code requires interlocking all woodworking machinery with dust collector to start fan, start /stop
station to work independently
C. Spark Detection System
1. FIlx 3001 type spark cetector is highly sensitive and reactira without delay upon detection of any infrared
radiation for temperature up to 176 degrees F
2. Single sparks or showers of sparks shot be detected immec ate', and transmit on electrical signal to the
control panel to shut down entire system.
3. Manual reset required for system operation
4. Two (2) detectors shall be located 180 degrees apart.
5. Detectors shall be provided with quick re ease mounting brackets for ease of cleaning and inspection
6. r e 3000 control panel
7. 120 volt dedicated circuit provided by others.
D. Fire Abort Damper
1. 14 Gouge galvanizes steel construction with (2) coats gray enamel finish
2. Exhaust usblast hood with birdscreen and drain.
3. Heavy duty spring assisted dampers with seals it both positions, open or abort for immediate action upon
detection of a spark or fire.
4. Automatic reset
5. 120 volt dedicated circuit provided by others
E. Return Air Filter Bank
1. Model 3P Glide Pack with Riga -Flo 200 final filters
2. Housing dimensions: 48 "H x 72" W x 21" D
3. 99% efficient on one micron particles as required by King County Fire Marshall
4. Dwyer 3000 Series water gauge /pressure switch provided to be instailc i on filter bank, shuts down the
system when reaches set maximum pressure drop
5. 120 volt dedicated circuit provided by others
F. Miscellaneous Ductwork Accessories
1. Style HG blast gates for connection cut -off
2. Type CWC flex hose for equipment connections where reauired (two feet per connection)
3. 18" diameter Fike explosion vent for installation in ductwork
4. Style 6 FS floorsweeps for pickup
2.2 DUCTWOPK
A. Ducts shall be constructed of galvanized steel welded or brazed and held air tight with "hard cast." Bare
steel areas to be touched up with zincilate 810 C, zinc rich coating. Duct and fittings to be manufactured
by the Kirk & Blum Manufacturing Company.
E For the duct system the following minimum metal thickness shall be applied:
Diameter of Straignt DJct,Elbows & Fittings U.S. Standard Gouge ForSteel Duct Class It
to 8" 22 gauge
over 8" to 18" 20 gauge
C. Elbows and angles shall be all welded high pressure type. Large radius elbows
D. Flexible piping shall to used to connect exhaust drop pipes to machines Flexible pipe shall be kept to a
length not to exceed 3v". Flexible pipe shall be Automation Industries, Inc., flexible Tubing Division,
"Spir.atube TDS ": nylon :over, with vinyl scurf straps. galvanized spring steel helix, nylon liner; with operating
range' of 1Cr to 200'F: or approved equivalen` Use stainless steel clomps and other accessories as
required for a complete installation.
SAW )JST COLLE,10N S fSTEim CtDNT1!!1UED )
PO' 3 ESC_ opN
3.1 ExA1la*IA
A_ Prior to pew rg irstalW-on etonine areas tc rece•.e dust collector ver'.fy that crinc crimerceis are
correct. end test con&tions are acceptrle
1_ Do not prr _eed until unsatisfactory candit.ces hove been corrected
12 !NSTALLATlCx,
,k. Genera Instce existing dust collector according :c 'nonu•acturer s lost ^actions.
B. Set sawdust co`ector securely and occurately in place; plumb. leve and prcpee aligned. Anchor as
required 'u- sec.re operation.
C. Complete `eid assernb.;y w to pints as recommended ov manufacturer Grind we an smooth and restore
finish Comply with KECA Standords for electrical wank
D. Exhaust s stern shall be constructed with the material stated herew e. cod seal: to - ^stalled in c
permaner and workmar ike manner Interior of all ducts shall be smooth and 'ref: "ern obstruction with
pints wee d c' riveted and held air tight with "hare east" mines. impreg^a•,ec woven fiber tape.
E. Longitudiee joints shall be continuously brazed or welded. Each component shicll be fabricated 'or
maie /ferrc :e girth pints. Installer to field trim to allow 1 lapping in director. of air flow.
F. Girth joints o' ducts shall be made with lac in direction of O flow, with 1" lop for ducts with diameters
up to '9 ° . These joints shall be riveted and taped wit, ° hard cast."
G. Elbows, 3" dior�ter through '5 diameter. s+ be constructed in one piece with brazed /welded throat
seams. Cente' ne radii shall be 2- times the diameter up to 14" diameter. and 2 times the diameter
above 14 diameter, unless noted otherwise
H. Provide dead end caps with handle for visual inspection where indicated or the drawings.
I. Provide clecnou1s every It feet and near each elbow, angle. or duct !unction in horizontal section. Doors
to be 4" r 6" 'or pipe through 8 ". and 6" X 8" for pipe 9" through 14 ". Doors to be as manufactured by
Kirk & Blum Manufacturing Company of Cincinnati, Ohio. Note doors an drawing submitted to Owner for
approval. Door shall be gasketed to be air tight.
J. Hanger rings shell be 1/8" ( 1" minimum band iron with one shop coat of primer. Hanger rings shall be
furnishes for intervals on ducts up to 8" diameter, and on. 20' intervals for larger sizes. Strop iron or
hanger rods cry not furnished by Kirk & Blum.
K. Provide 6" mir -um clearance between ducts and ceiling, wall, or floors.
L All branches she enter the main at the large end of the transition at an angle not to exceed 45; 30' is
recommended. All ductwork (turns, transitions, hoods, etc.) shall be in accordance with American Conference
of Government: Industrial Hygienists "Principle of Duct Design."
M. Transition in mans and sub -mains shall be tapered; taper 8" long for each 1" change in diameter.
N. A cost a uminu- blast gate shall ne provided at each machine or floor sweep. Blast gates shall be Kirk
& Blum. They shall be mounted 6' -0" off of floor.
O. Provide Kirk & Blum or Car -Mon manufactured "floor sweeps" where shown er required. Floor sweeps shall
have 4" X 11 '2" hinged doors. and shall be constructed of '8 gauge galvanized steel. Duct connections
shall be 5" ant 6" in diameter. "Home made" type will not be acceptable.
M 0 I --- I 5 i
ACCEPTABILITY
THIS DESIGN AND /OR
SPECIFICATION IS APPROVED
APPROVED BY
DEPT.
I
DRAWN
VFW - DLR GROUP
TOED
ITNCINEER
DATE PP
'NECKED
APPROVED
^ " ROVLD
NN E
DATE
07.17.2001
07.17.2001
L
�DC
SAWDUS
COLLECTOR
STERNVENT
3000 PSI
CONCRETE
PAD
SUBTITLE
TITLE
7
ABORT
ELEVATION VIEW
DUST COLLECTO3 LETAIL
SCALE: 1 /4" = 1' - 0'
r3 4 a n 1 i
SECTON
SCALE: NONE
MECHANICAL MASTER
\- HOUSE KEEPING =AD
COOK W/ AFChi iRWGS
PLAN VIEW
PROVIDE GALV.
UNISTRUT DUCT
SUPPORTS -
HOUSEKEEP!NC PAD
COOK 'A, AiRCH DRAGS,
`- SPARK DETECTOR
44112)
M522
#4 @ 10 "
O.C. E.W.
BUILDING 9 -99.1
COL. A -C/ 1 -4
9 -99 MODEL SHOP - PHASE 1 AND 2
DETAILS - DUST COLLECTION
i
---OP- . -4..
PERMIT SET
/-- 72X48 RETURV ;mu
E'.»*; : f3.4
w - 35 rr511 16"-C"
1i`"�1 rY s. r F
24 #?L_'. /} MO n C 0 171.' iAMPE; DOSES
WHEN rLO M * :.!, :EMSE
FLOW I'd SPR!N• -r; P BRANCH oePE
TO DUST COLLECTOR DC-2
1
FINAL c TER AS7_14BL`
SPRINKLER UNE
M522
/-- EX _ST DUCT
WI' • BOTTOM 16' -0"
M" d +MUM A.F.F.
- - '2x48 RE =N GF E
lee
J
FINAL =ILTER ASSEMBLY
FINISHEL FLOOR
1
1M10 M522
D.
t
SHEET
SAWCLIT ASPHALT
z___________
ASPHALT
/ EXIST. 2" ASPHALT opj
i pPRie
COMPACT SUBGRADE
TO 95% MAX. DRY
DENSITY
CURRENT REVISION I S(MBOL
'00015 -00
M522
JOB NO.
100015 - 00
Dwc NO
9 - 99 -M522
cg 214 ` o%\
RECEiVEO
nine OF Ti IvH,'li 1
Al;I. %fit.
PERMIT '.;ENTER
DATE
07 31.01
COMP NO.
MARK
SENS
CAP
MBH
STEAM COIL
STYLE
MOTOR DATA
BASIS OF DESIGN
UNIT DATA
!BASIS OF DESIGN
NOTES
FLOW
LBS /HR
PRESS
PSI
TRAP
CAP
LBS /HR
CFM
NON/
E.A.T ;
F
LA T
=
I
HP V
AMPS.)
PH
THROW
DIRECT.
MOUNTING
HEIGHT
:-'
U H -1
80
80
50
240
1,420
68
120
1/20
120
1
24'
BELOW ROOF
RELOCATE ;XISTING TRANE 80 -P
1
UH -3
1,050
1,050
50
3,150
15,000
15 I
104
3
480
3
24'
BELOW ROOF
EX:ST1N., TO REMAIN
2
_
DUST COLLECTOR SCHEDULE
MARK
SERVES
STYLE
BLOWER MC. 'OP
BASIS OF DESIGN
NOTES
C, c M
E.E'
HP
RPM
VOLTS
PHASE
DC -1
NW WOODSHOP
NON RECIRCULATING
1,800
E'
5
1750
460
3
RELOCATE EXISTING TORIVENT MODEL 90
1,2
DC -2
SW WOODSHOP
RECIRCULATING
5,600
T.'?"
15
3450
460
3
RELOCATE EXISTING STERN VENT MODEL OEH 815- 4
1,2,3
STPI!CTURE LAB UPGRADES
Pf.vISION
R 9 - '49 MODEL SHOP - PHASE 1 AND 2 J0100015 -01
BY
KGP
DLR GROUP
APPROVED I DATE
06.30.99
RP 07 31.01
PIPING SHALL BE 'NSTAL_ED IN TRUSS SPACE TO ALLOW FOR DRAINING OF CONDENSATE.
RELOCATE EXiST'NG STEAM ;.IN.T HEAT FRCADE NEW1 -'%4" STM SUPPLY AND '" COND RETURN PIPE, CONTROL VALVE. TRAP. 'SOLATION
VALVES. BYPASS, STRAINER, UNIONS. ANC INSULATION.
REVISION
THRU BOLT , 12) WALL STUDS
USE (2) 18" UNISTRUT
AS BACKING PLATES
SCALE LEG
WITH
STEAM TRAP
Qr -PAS;
hTROL VALVE
AMP
- Ir D`•_t-
•- 66s E?°'(A EP
( ) I
STEAM COIL - LOW PRESSURE
1 M5 M522 !!T8
FINISHED FLOOR
BY
APPROVED
DATE
UNISTRUT P -1000 0 6' - OC.
SECURE TO (2) METAL WALL
STUDS WITH 3/8" DIA.
AHD. ROD (2 THD. ROD PER
STUD . 4 TOTAL)
6 " -16 GA METAL STUDS
® 16" O.C. W/ 5/8" G.W.B.
TRUE FLOOR TO CEILING WALL
WALL FASTENED TO OPEN - WEB TRUSS ..
18 GAx1 1/2" SHEET
METAL STRAP W /(2) P1010 1/2"
UNISTRUT NUTS & BOLTS
MAIN TRUNK (SIZE VARIES)
MAX SUPPORT
SPACING: 6' -8" OC
SLIDE GATE
40 LATERAL TAKE -OFF
(TYP AT 4 MACHINES)
""*.- 40
INICTRUT P -2514 BRACKET
SPACED W 6' -8" O.C.
ELEVATION VIEW
D UCT SUPPORT DETAIL n
T A,F• N(NE 1M10 M523
SEAM • • L •
14Lpe•
^JRL, VAIN
RELOCATED MACHINE
7 (SANDER, SAW OR GRINDER)
MOI151
UNISTRUT STAND
P2072 POST BASE W/ (2) 1/2"
A. BOLTS 2 1/2" MIN. EMBED.
P1000 UNISTRUT (HEIGHT AS REO'D)
W/ P1047 FITTING
EXPIRES: 1
DUCT SUPPORT
FINISHED FLOOR -
1
DUST COLLECTOR DETAIL
SCALE: NONE
ACCEPTABILITY
THIS DESIGN AND /OR
SPECIFICATION IS APPROVED
APPROVED BY
=ACE OF
EXTERIOR KDO WALL
AFF
I
REL OC.ATEE T 2IP!T
ELEVATION VIEW
NOTES: 1, RELOCATE EXISTING STEAM UNIT HEATER. PROVIDE NEW 1 -1,'4" STM SUPPLY AND 1" COND RETURN PIPE, CONTROL VALVE, TRAP, ISOLATION
VALVES, BYPASS, STRAINER, UNIONS, AND INSULATION.
2. REVISE DISCHARGE DUCT TO CLEAR CRANE RAILS
NOTES: 1. SINGLE POINT ELECTRICAL CONNECTION
2. U.L. LISTED WITH INTEGRAL STAND, MOTORS. SAFETIES
3. PROVIDE NEW SPARK DETECTOR. ABORT DAMPER AND FINAL FILTER FOR REDRCULATION OF AIR
AWN
M DITTMAR
CHECKED
ENGINEER
DEPT. DATE T. HANSON
Cr EC
APPROVED
APPROVED
-- TORIT DUST COLLECTOR.
EXPLOSION VENT
HOA SEE ELEC DRAW,NGS
PNL Cl CKT 26
0 " -8" MAGNAHEUC PRESSURE GAUGE
MANUAL LEVER
INSTALL (4)
1/2" DIA. HILT' KM< BOLT ii
A. BOLTS MIN. EMBED. 4
(1) A. BOLT PER BASEPLATF
PEP MANUFACTURE
A
(
1M11 M523
09.09.93
09.09.93
SUBTITLE
TITLE
MLUHANICAL MASTER
9 -9'? MODEL SHOP - PHASE 1 AND 2
BUILDING 9 -99.1
COL. A-C/1-4
EXTERIOR
Eta; WA_
PERMIT SET
DETAILS - DUST COLLECTION
INSTALL .8"'S x 14 "OG r 1 6 GA
SHEET METAL COLLAR ATTACH
TO SUPPORT FRAME WTTr 3 1
1
SELF-TAPPING SCREWS
STEAM UNIT HEATER SC HEDULE
SCALE: NONE
RELOCA T E; TORT
SHOW NIPPLE
STANDA ''UPLEX ,A R OUTLET l�
SCALE: NONE 1M602_1523
D.0
/ — 1/2" TEE
�- 1/2" STREET EL TYF
i
JOB NO.
DVVG NO.
�- L3 - K3 - 1/ F"> L GTH AS REO'C
(TYPICAL, ,EC 'RE TO EXTERIOR
BLDG WA_ N ' '4` 1/2' DIA
H!LTI WI( BOLT I! 3 1/2" MIN. EMBED.
r ' 1
M523
1/ BR')NZE R'SNG STEM GATE VAL■.=
�- 1/2 "x1,4' BUSHING TY?
Npl A
e pee
� — H ANSEN SERIES 400( 1/4"
OU!CK DISCONNECT
ONE WAY SHLTOFF
ORRENT REVISION
1 00015 -00
SHEET
/-- 1/2" GAL... PIPE
/-- 2" COMPGESSED ATP MAIN 1 E)
AIR OUTLETS 4E" AFF TYP
SYMBOL
M523
100015 -00
9 -99 -M523
cl,TnEaO A
ALT)
•rf
P IJ&N F,.
DATE
07.31.01
COMP NO.