HomeMy WebLinkAboutPermit M01-165 - BOEING #9-102M01-165 Boeing 9-102 9725 E Marginal Wy S EXPIRED APR 1 8 20132 City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: MO1 -165 Type: B -MECH Category: NRES Address: 9725 EAST MARGINAL WY Location: Parcel #: 000340 -0018 Contractor License No: TENANT BOEING #9 -102 9725 EAST MARGINAL WY S, TUKWILA WA 98188 OWNER BOEING PO BOX 3707 - M/S 1F -09, SEATTLE WA 98124 CONTACT RICK FORD P.O. BOX 3707 M/S 1W -08, SEATTLE, WA 98124 * * * * ** * * * * * * * * * * * * * 'A * * k * * * A * * * * k k * * * * * * * * A * * A *• * * * * k A A A k k k * * k * k * A• * * * * A k * * * A Permit Description: REPLACE 500 TON COOLING TOWER ON ROOF OF 9 -102 BUILDING UMC Edition: 1997 Valuation: 8,000.00 . Total Permit Fee: 73.13 *****,*;** A*** k************************: A* ***A*•k* *k * ** **•** * ** ** ** * ****A • PerMi t ?r'nter Authorized Signature MECHANICAL PERMIT Date Phone: (206) 431 -3670 Status. ISSUED Issued: 10/18/2001 Expires: 04/16/2002 Phone: 206 655 -9888 I hereby certify. that I have read and examined this permit and know the same',-to be true and correct. All provisions of law and ordinances governing this work will be, complied with, whether specified herein or not The`granting'.:of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Signature: � �� =-- Date: Le,,,liko t Print Name: Title: This permit shall.-become null and void if the work is not commenced within 180 days from "the -date of issuance, or if the work is suspended or abandoned for a period of,180 days from the last inspection. PERM!T cc ar ;D crn PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PROJECT NAME: BOEING 9 -102 - COOLING TOWER SITE ADDRESS: 9725 E MARGINAL WAY SOUTH Original Plan Submittal Response to Correction Letter # M01 -165 DATE: 10 -10 -01 XX Response to Incomplete Letter #1 Revision # After Permit Is Issued DEPARTMENTS: Build n Division Ib - I1 ci Public Works n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete \PRROUTE.DOC 5/99 TUES /THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Fire Prevention f 'w L 10-11.-6( Structural Approved n Approved with Conditions CORRECTION DETERMINATION: Approved ri Approved with Conditions Fl Planning Division n Permit Coordinator Y DUE DATE: 10-11-01 Incomplete ri Not Applicable Comments: No further Review Required DATE: DUE DATE 11 -08 -01 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: DUE DATE .::�(ii:.; tai., ..... %;t.:s;%:,1:.w:iti;:L:.i'si i�)iiF✓?a1y:�,ui; :' n,.' :: i' iix'�� >It�:y.r,'.'*n�;s «:6.:: c�: tr• YlJi: �;` d`. revr5: e" rti"` Y . " iS: YkI,'+p. 4Vv: Sif' fr, n" SI' r': September 27, 2001 Mr. Rick Ford P.O. Box 3707, M/S 1W-08 Seattle, Washington 98124 City of Tukwila Department of Community Development Steve Lancaster, Director RE: Letter of Incomplete Application #1 Development Permit Application Number M01 -165 Boeing 9 -102 — R & R Cooling Tower 9725 East Marginal Way South Dear Mr. Ford: This letter is to inform you that your permit application received at the City of Tukwila Permit Center on September 24, 2001, is determined to be incomplete. Before your permit application can begin the plan review process the following items need to be addressed. Building Division: Ken Nelson Plans Examiner at (206)431 -3670, if you have any questions regarding the following: Separate building permit required with structural calculations. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. If your revision does not require revised plans but requires additional reports or other documentation, please submit four (4) copies of each document. In order to better expedite your resubmittal a `Revision Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 433 -7165. Sincerely, e c- G Stefania Spencer Permit Technician encl File: Permit File No. M01 -165 / M Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: PROJECT NAME: BOEING 9 -102 - COOLING TOWER SITE ADDRESS: 9725 E MARGINAL WAY SOUTH Response to Correction Letter # M01-165 DATE: 10 -10 -01 Original Plan Submittal XX Response to Incomplete Letter #1 Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Please Route n TUES /THURS ROUTING: REVIEWER'S INITIALS: \PRROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete Structural Review Required REVIEWER'S INITIALS: V' APPROVALS OR CORRECTIONS: (ten days) Approved I I Approved with nditions p - ert,„ 4- - b() CORRECTION DETERMINATION: Approved Approved with Conditions n n n Planning Division Permit Coordinator [ DUE DATE: 10-1 1-01 Not Applicable No further Review Required DATE: ( v (c (d DUE DATE 11 -08 -01 Not Approved (attach comments) DATE: t0. 17 -Z(il n DUE DATE Not Approved (attach comments) REVIEWER'S INITIALS: DATE: II l 2 ¢..V.INO *. 0 1 4 4 +c7iu7:.K:az.�ic.sr;:� "+r.`'i'P t$ V%s ° �:,4iv<(•'i PERMIT NO.: Mo - 45 MECHANICAL PERMIT APPLICATIONS INSPECTIO ❑ 00002 Pre - construction ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation/Indoor AQC ❑ 00610 Chimney Installation/All Types ❑ 00700 Framing ❑ 01080 Woodstove ❑ 01090 Smoke Detector Shut Off ❑ 01100 Rough -in Mechanical ❑ 01 101 Mechanical Equipment/Controls ❑ 01102 Mechanical Pip/Duct Insul • ❑ 01105 Underground Mech Rough -in ❑ 01115 Motor Inspection ❑ 1400 Fire Final 01800 Final Mechanical ❑ • 04015 Special -Smoke Control System CONDITIONS 000 No changes to plans unless approved by Bldg Div 0014 Readily accessible access to roof mounted equipment ❑ 0016 Exposed insulation backing material 0019 All construction to be done in conformance w /approved plans 0002 Plumbing permits shall be obtained through King Co 0 027 Validity of Permit 003 Electrical permits obtained through L & I ❑ 0036 Manufacturers installation instructions required on site ❑ "BTU maximum allowed per 1997 WA State Energy Code" ❑ 0041 Ventilation is required for all new rooms & spaces ❑ . "Fuel burning appliances ❑ . "Appliances, which generate...." ❑ "Water heater shall be anchored...." Additional Conditions: FEES ,z Basic Fee (Y /N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace/Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor- mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qry) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qry) to 50 HP /1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qry) Air Handling Unit to 10,000 cfrn (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qry) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm/Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter SS) Add'! Fees — Work w/o Permit (Y/N) [nsp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'l Plan Review (hrs) Plan Reviewe Permit Tech: Date: Date: iO 17- Zool ACTIVITY NUMBER: M01 -165 DATE: 9 -24 -01 PROJECT NAME: BOEING 9 -102 — R &R COOLING TOWER SITE ADDRESS: 9725 EAST MARGINAL WAY SOUTH XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: ui ding Division • Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES /THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE 10 -23 -01 Approved n Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved Approved with Conditions n REVIEWER'S INITIALS: \PRROUTE.DOC 5/99 PERMIT C COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Planning Division J6 % 7 Permit Coordinator Ar DUE DATE: 9-25-01 Incomplete Fr Not Applicable n No further Review Required I I DATE: DUE DATE Not Approved (attach comments) Li DATE: ^ �....� �`i.S:a ° Sl »XZ:h�Mti:a n. ..l iVt.r ACTIVITY NUMBER: M01 -165 DATE: 9 -24 -01 PROJECT NAME: BOEING 9 -102 - R &R COOLING TOWER SITE ADDRESS: 9725 EAST MARGINAL WAY SOUTH XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions Not Approved (attach comments) Ti DATE: l p O / REVIEWER'S INITIALS: DUE DATE Not Approved (attach comments) REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: Approved r i Approved with Conditions \PRROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP n n Fire Prevention Structural Incomplete n Structural Review Required [I Planning Division Permit Coordinator DUE DATE: 9-25-01 Not Applicable No further Review Required DUE DATE 10 -23 -01 n J Yx.' `iI3`a7'.�':Ilhir.l;i4i;:3k•r ACTIVITY NUMBER: M01 - 165 DATE: 9 -24 -01 PROJECT NAME: BOEING 9 -102 - R &R COOLING TOWER SITE ADDRESS: 9725 EAST MARGINAL WAY SOUTH XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Incomplete Comments: w t S'IYV LA-a c c u, [ - TUES /THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: Approved \PRROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Approved with Conditions n Permit Coordinator II REVIEWER'S INITIALS: Planning Division DUE DATE: 9-25-01 Not Applicable DUE DATE 10 -23 -01 No further Review quired DATE: i S� (� I DUE DATE Not Approved (attach comments) DATE: - o*A%wv,+. sma :rF'�iiV,:,t •P+, 1 0 :iC :.t46 =! :G3`r;51 Project Name/Tenant• X. e 9- 5Y7) 7 Di-) Z?4017 L /X i 4 7 X".2 Value o Construction: A DZ).9 Site Address : City State/Zip: 9 .C. 1410 2I.,/,-/ft a L 4v if' y Tax Parcel Number: aec.34etao18 Phone: ( ) Property Owner: Fi iv 1 e . Street Address: City State/Zip: Fax #: ( ) City /Sta e/Zip: Contractor: -. £7 23e a - i rcte 214 wt L Phone: ( ) Street Address: City State/Zip: Fax #: ( 1 Architect: Phone: ( ) Street Address: City State/Zip: Fax #: ( ) Engineer: Phone: ( ) Street Address: City State/Zip: Fax #: ( ) Contact I /1, � . 02 1 Phone: ) ` G _ g egB Street Address: P. p. ,6 o r 3707 // � City State /Zip: 7 /5 /tv OS S e r w 4.4.4 Fax #: ( ) MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specific): .. R e/0 I ac a 9 Ccd� 1 P_..p- o M. rc 4 a4' 9 -/D2 & 'l /d S Tou /v 1 Will there be storage of flammable/combustible hazardous material in the building? ❑ yes ❑ no Attach list of materials and story a location on separate 8 1/2 X 1 aper indicating quantities & Material Safety Data Sheets ❑ Above Ground Tanks Antennas /Satellite Dishes El Bulkhead/Docks ❑ Commercial Reroof ❑ Demolition ❑ Fence ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /Sta e/Zip: 0 Water 0 Sewer 0 Metro 0 Standby CITY OF TUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Number. Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. mo i- 14.6 Miscellaneous Permit Application APPLICANT REQUEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelization /Striping ❑ Flood Control Zone Landscape Irrigation Storm Drainage Water Meter /Exempt # Water Meter /Permanent # Water Meter Temp # Miscellaneous ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 _sq. ft.grading/clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public Size(s): 0 Deduct 0 Water Only Size(s): Size(s): 0 Moving Oversized Load/Hauling Est. quantity: gal Schedule: WATER METER DEPOSIT/REFUND BILLING: Name: I Phone: Address: City /Sta e/Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date applicatexpire Date application acce ted: IP ri-0/ 9/9/99 miscpsu.doc and is subject to by limitation. The applicant as defined Application taken ._._....__.,..._..- �..u..c.......�.........a... .:�mw.w�:, «. >, 1111... BUILDING:O OR AUTHORIZEDAGENT: PIRMII RIVIFW Submit checklist No: M -9 r Signature: Submit checklist No: M - 1 / J g/ Bulkhead/Dock: Date: Print name:. /Lr e F.- - ,912_D � Phone. ( a a(a sS - 69S46 Fax #: ( ) Submit checklist No: M -9 Address:: ,Land Altering/Grading/Preloads Submit checklist No: M -2 ,City /State/Zip: Miscellaneous Public Works Permits Submit checklist No: H -9 ALI MISCELLANIEOVS P IT APPLICA MUST BE SWIM! WITH THE FOLLOWING: • ALL DRAWINGS SHALL BE Al" A LEGIBLE SCALE AND NEATLY DRAWN D 'B011.DING SITE PL»Nq AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT > STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER > CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) 0 Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Buildig,Owner/AuthoriedAgent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the ,State of Washington, a notarised letter f rom: . the property owner authorizing the agent to submit this permitaapplication:and obtain;the permit will be required as partof this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 9/9/99 r �y ' � •}'"; miscpml.doc nom.. 4 41,4 SUBMIT APPI I( AIION AND RI (21MIROI) ( Ill( KI ISIS IOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PIRMII RIVIFW Submit checklist No: M -9 r Antennas /Satellite . Submit checklist No: M - 1 Bulkhead/Dock: Submit checklist No: M -10 Commercial Retoof Submit checklist No: M -6 0 Demolition Submit checklist No: M -3 Fences - Over 6 feet in Height Submit checklist No: M -9 r ,Land Altering/Grading/Preloads Submit checklist No: M -2 O Miscellaneous Public Works Permits Submit checklist No: H -9 0 ; Manufactured Housing (RED INSIGNIA ONLY) Submit checklist No: M - 5 Moving Oversized Load /Hauling ''" " °' Submit checklist No: M - 5 0 :Parkin Lots. "'h : Submit checklist No: M-4 O Retaining Walls - Over 4 feet in height Submit checklist No M -1 Temporary Facilities Submit checklist No M - 7 Tr ee'Cutting Submit checklist No M - 2 ALI MISCELLANIEOVS P IT APPLICA MUST BE SWIM! WITH THE FOLLOWING: • ALL DRAWINGS SHALL BE Al" A LEGIBLE SCALE AND NEATLY DRAWN D 'B011.DING SITE PL»Nq AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT > STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER > CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) 0 Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Buildig,Owner/AuthoriedAgent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the ,State of Washington, a notarised letter f rom: . the property owner authorizing the agent to submit this permitaapplication:and obtain;the permit will be required as partof this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 9/9/99 r �y ' � •}'"; miscpml.doc nom.. 4 41,4 •,::utia:'di.'ti ;iJ.•;z..i' i:.!: tl,. ii?.Y.:'- �i::;cN.::,;: ?= %ZSxa2� t: .. Address: 9725 EAST MARGINAL WY S Suite: Tenant: BOEING #9 -102 Type: B-MECH Parcel #: 000340 -0018 CITY OF TUKWILA l j Permit No: MO1 -165 Status: ISSUED Applied: 09/24/2001 Issued: 10/18/2001 * l***• k*• k****• k kk*• Ak• k• k***• A A*** A*A A k kA*** kA• AA k• k* A*• Ak * **A* *kA * * *A;@ * *•k•k *A *AA Permit Conditions: 1. Readily accessible access to roof mounted equipment is required. . 2. Plumbing permits s hall ;be. obtained _ :through the Seattle -King County Department of Public Health Plumbing will be inspected by,that' agency, 'including all gas piping (296 -4722) Electrical 'permits,shall be obtained through the Washington ;State Division Of and, Industries and al) electr.ical wort; wi4:l`' be i nspected - by that agency (248 - 6630) No changes •:-"wi 1 1'' be made to 'the, plans un l ess approved by the Engineer. and the Tukwila Building Division. Al 1 r.Nernr'i ts, Inspect ion `.re,cords, ` and approved plans shall '. be avai;-lable'at the jobsite` "prior to the start of any con struct i on These .documents :are to be maintained and avail - a until 1, final inspection` approval is granted. A construction to done'. in conformance with approved pions and requirements of ; the Uniform Building Code (1997 Ed :ition) as. amended, Unisform;Mechanical Code (1997. Edition) an' d: Washington State Code •(1997 Edition) . UalidiWot Permit.: The Issuance of a permit or approval of . pl' ans,; specifications, and computations shall not be con - st`rued to be a Permit for, or . an approval of, any violation of :any of I the provisions of the building code or of any other'''ordinance of the jurisdiction. No permit presuming:'to gi_ve, autlority to violate or cancel the provisions of this coder e st a,ll be valid. . Manufacturers installation instructions required on site, forjye buil.ding' review: * * *FIRE CONDITIONS *•k The at- tached t'set of plans have been reviewed y, ewed l' -The Fire Prevention t:.Bu"reau and are acceptable with the following concerns: H: V. A. C, uni:.t at greater than 2,000 cfm. require auto- shutdon `devices. These devices shall be separately ' w zoned in the alarm, and' local U.L. central station supervision is required d : (City • #1900) H V. A C, systems supplying ' air _ in_'excess• of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 13'.' Duct smoke detectors shall be capable for being reset from the alarm panel. (City Ordinance #1900) 14. Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance #1900) 15. In areas that are not continuously occupied, automatic smoke detection shell be provided at each control unit(s) location to provide notification of fire at that location. (NFPA 1 -5.6) 16. The installation of wiring and equipment shall be in accordance with N.F,P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72 -1- 5.5.4) 17,When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #1900) • ,Dedicated fire alarm system circuit breaker(s) shall be :._equipped with a, mechan ical lockout device. (NFPA 72 , (1- 5.2.5.2)) All new fire alarm, systems' or modif ications to existing systems shill have;. the', • written approval ''of ;ithe Tukwila Fire Prevent,tOn :'Bu,reau'. :, No worn shall 1 commence .urit i l a fire e department permit has, obtained.. (City Ordinance # 1900;) -tip l UFC : 1001.3) "' • Contact the Tukwila Fire Prevention Bureau to witness al . requi;riedyinspections,and tests. (UFC 10.503) CCity Ordi rance/ #1900 and #19'01) • Du;ci" detectors shall 'send a . . supery i sory signal o n l y upon at a v at i o n • Any overlooked hazardous condition..and /or violation of the da pted Fire or Building Codes . does not imply approval of ;su:ch condition or- violation. • The plans were reviewed by 511. 'If' you have any questions, ease . call the Tukwila Fire Prevention Bureau at (2,06) - 575 -4407. !rint.Name gna.tl.lre,: T hereby„ cent i'fy-that I ` have read 'these . cond.it i ons and will comply with th"ej as: outl'ined. All provisions of law and ordinances governing this work, will 1` be , complied with, whether specified herein • or not ti :The gran.t;i ng of this',: does not presume to give authority to v iolate c4, the provisions of any other work or local laws regulating;c or the performance of work.. .. �e. , <i;SS�..ra�Y•s :n+.'�ne; : :•F2'� fa,�,". = :�i ::,..inn. : �f { r 't ^;u�:aP � �^:tr�.`i'.,R:b S 1('= .tn ! '':'ri k �'t� "J " n �l`1 ; �i a y;�r, ' !V ♦r`� •a �.;�r;lS�.,.,k. %1 }�e::�.� ��.�;;:,;� <F.i�:�;.$;lyj e .14 A ik • 4: 4 ** , A hA•** k*•-**hk hoF kth *A *•A:lhk•Jk•!t4 *'**h *.t *A** .44.*Akk *AA4.kA. %*Ak C TY OF TUKWILA, WA TRANSMIT ANSMIT J r hq4h Ark** * *A'*AkAAlicA** *h** *,4 *<t*A** *:**Ak ***A*Akh*•kk* *N ***A *,%A*A TRANSMIT = Number 80101350 Amount: 73.13 10/1,61. 01 11:03. Payment Method TRUST Notation: BOEING Init.: b$(`3 er^mit No 1101.165 Type: B• -MECH MECHANICAL PERMIT Parcel •No: 000340 -0010 Vte Addrrssa..9725 EAST MARGINAL WY S Total i•eee: 73.13 73. "13 Total AL.L Pmts: 73.13 Balance: .00 r4 ' A,: t• A' *.* k:t *-kAFA•,l• * *khhk *kkAk. *Ak•k* *A *A'• *:t *A•k **•h ** * ** *kk ** *•k:4* .ACL oUn • G, a_de . 0es.cription ' Amount 0 ) 0, 3 :10 PLAN CHECK •- NONRES 14..63 000/322..'100 • :MECHANICAL -• NONRES 51:3,.50 • o-3 April 4, 2002 Mr. Rick Ford P.O. Box 3707 M/S 1W-08 Seattle, WA 98124 Department of Community Development Steve Lancaster, Director Dear Permit Holder: City of Tukwila RE: Permit Application No. M01 -165:, Location: Boeing 9 -102 9725 E. Marginal Wy S In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to schedule a progress or a final inspection A progress inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicant's control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to April 16, 2002, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Cell 141 Kathryn A. Stetson Permit Technician Xc: Permit File No.M01 -165 Bob Benedicto, Acting Building Official EXPIRED APR 18 2002 Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 - 3665 r z:x:l.8urinf?c, z W UJ V 0 N 0, N UJ g J; e o . Z �.. O co' W ▪ W '. u . Z ' 0 N • •'••• •: ,.'• Balance Due: Due: $ 13, / 3 Need Current Contractor Registration Card: jJ Yes Need to Enter Contractor Information in Sierra: El Yes Inib • • , , • •.• • • *,•4 DRAWING INDEX SHEET N0. DRAWING N0. SHEET TITLE SHEET N0. DRAWING NO. SHEET TITLE Al 9- 102 —Al TITLE SHEET S260 9- 102 —S260 STEEL SCHEDULE M1a 9- 102 —M1a EQUIPMENT SCHEDULE S502 9- 102 -3502 SECTIONS AND DETAILS M450 9- 102 —M450 ENLARGED PLAN M507 9- 102 —M507 SECTIONS AND DIAGRAM M508 9- 102 —M508 PARTIAL PLANS, SECTION, & DIAG. M509 9- 102 —M509 DIAGRAM AND DETAILS E -130 109- 102 -2003 CLG. THU . #3 CONTROL DIAGRAM E -131 109 - 102 -2001 CONTROL SCHEMATICS & DE TAILS E -132 109 - 102 -200^ CHILLER POWER PLAN E -135 109 - 102 -2002 CHILLER MTR CONTROL CENTER E502 9- 102 —E502 PTL PLANS, SECTION, & DIAGRAM 5160 9- 102 --T60 ROOF FRAMING PLAN SYM VICINITY MAP x201 PROJECT SITE 99 FROM SEATTLE— TACOMA AIRPORT FROM IOWNTOWN SEATTLE tN BOEING ACCESS RD \, \ \\ \ �Y is , \.` I n \ \,� ^ \\ \ N � ` - -, ,„, T ' \ \ ---' �/ � � � , 599 / j, i f EAST MARONAL WAY ' TUKWILA ' L; CORPORATE PARK lfi DEVELOPMENTAL CENTER REVISION BY INSTALL COOLING TOWER J#793722 -00 CFH AHPROVED DA E S'YM 09.12.01 BOEING DEFENSE & SPACE GROUP REPLACE COOLING TOWER J #703542 -00 ■ Y d '�- Q FROM KENT & AUBURN E T i 57 900 NO SCALE REVISION BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 AREA MAP BLDG. ADDRESS: 9725 E. MARGINAL WAY S. TUKWILA,WASHINUTON 9 -101 BUILDING LOCATION APPROVED DATE I I�4 III NO SCALE Off ,Iw FACILITIES DEPARTMENT GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO CHUCK HARRAH AT BLDG. 9 -51 COL L /2, AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT CHECKLIST CHECK BOX • THESE DRAWINGS CONFORM TO THE 1997 U B C, U.F.C., U.P.C., AND THE BARRIER FREE CODE AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ❑ ENGINEERING CALCULATIONS ( IF APPLICABLE ) ® ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10 —A. ® BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. GENERAL PERMIT (SHELL & CORE) 4 SETS OF ENERGY CALCULATIONS 2 SETS OF CIVIL DRAWINGS WITH UTILITIES 2 SETS SOILS REPORTS, STAMPED BY GEOTECHNICAL ENGINEER 2 SETS STRUCTURAL CALCULATIONS 5 SETS PROJECT CONSTRUCTION SPECIFICATIONS 5 SETS TOPOGRAPHICAL SURVEY 5 COPIES OF LEGAL DESCRIPTION 5 SETS OF WORKING DRAWINGS ❑ 2. TENANT IMPROVEMENTS, (NON — STRUCTURAL) —4 COMPLETE SETS ® 3. MECHANICAL, 3 COMPLETE SETS ❑ 4. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS ❑ 5. TENANT IMPROVEMENTS, (REVISIONS), 2 COMPLETE SETS. • BRIEF PROJECT NARRATIVE REMOVE AN EXISTING 500 TON COOLING TOWER AND REPLACE WITH A NEW 500 TON TOWER. ❑ AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 ■ SEATTLE, WA. 98124 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVE APPROVED B DEP DA DRAWN BY D.R. CHESTERFIELD CHECKED CHECKED APPROVED APPROVED CODE SUMMARY LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS TUNNEL FIRST FLOOR MEZZANINE BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQLIREMENTS FIRE PROTECTION SEISMIC ZONE 4/1 SUBTITLE TIE BLDG 9 -101 FILE COPY M I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. By Date /p Xef G Permit No. REVISIONS CK =J SHALL BE K :J 6L4Y ID:_I�t]c - 3 TITLE SHEET ARCHITECTURAL MASTER TUKWILA 1997 UBC, WASHINGTON STATE ENERGY CODE, WASHINGTON STATE BARRIER FREE CODE AND ADDITIONS PER CITY OF TUKWILA GROUP B (OFFICE) AND GROUP F, DIVISION 1 (AIRCRAFT) TYPE II, NON— COMBUSTIBLE SEPARATION 60 FEET (MINIMUM ALL SIDES) MO1 -165 BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL ELECTF.ICAL fitPLUMBING If GAS PIPING CITY OF TU BUILDING D. D.0 SHEET JOB NO DWG N0. Pi APR i a 2002 Clay Cr �UKN:::; PE,SI Y CRNTE: LAST REVSION I SYMB Al 9- 102 —Al DATE Or II I s PUMP SCHEDULE MARK NUMBER SERVICE FLUID TEMP F CAPACITY SIZE PERFORMACE MOTOR PUMP TYPE REMARKS GPM TDH SUCT DISC EFF NPSHR DRIVE HP RPM VOLTS PHASE HERTZ P -1 SECONDARY CHILLED WTR WATER 38 512 35 3 2 1 / 2 - - FLEX CPLG 7 1 / 22 1,750 480 3 60 CENTRIFUGAL PACT LER 30 MODEL 90 640 -7 NZE FI IYP L, END SUCTION SIZE 4x5x7' IMP , TTE PACT MQDEL 8q4070 -7 ZE FITTED TYPE L, END SUCTION SIZE 4x5x7 PELLER 309b, BRON PALO RONZE FITT MODEL E6 $6095 - 1 TYPE LF, END SUCTION SIZE 6x8x9.5 B P -2 SECONDARY CHILLED WTR WATER 38 512 42' 3 2 1/2 / 2 - - FLEX CPLG 7 1 / 1,750 480 3 60 CENTRIFUGAL P -3 SECONDARY CHILLED WTR WATER 38 1221 42' 3 2 - - FLEX CPLG 20 1,750 480 3 60 CENTRIFUGAL P -4 CONDENSER WATER WATER 92 600 46' 3 2 - - FLEX CPLG 10 1,750 480 3 60 CENTRIFUGAL RECIPROCATING P -5 CONDENSER WATER WATER 92 600 46 4 3 - - FLEX CPLG 10 1,750 480 3 '60 CENTRIFUGAL P -6 CONDENSER WATER WATER 92 1500 46' 4 3 - FLEX CPLG 25 1,750 480 3 60 CENTRIFUGAL PALO ONZE DEL D 6095 - 1 T YPE LF, END SUCTION SIZE 6x8x9.5 BR P -7A &B PRIMARY CHILLED WTR WATER 38 1536 90' 4 3 - - FLEX CPLG 50 1,750 480 3 60 CENTRIFUGAL P -9 SECONDARY CHILLED WTR WATER 11 1221 42' - 4 - - FLEX CPLG 20 1,750 480 3 60 CENTRIFUGAL MODEL #6095 -1 TYPE LF, END SUCTION SIZE 6x8x9.5 BROPALO NZE FITTED P -10 CONDENSER WATER WATER 92 1500 46' - 4 - FLEX CPLG 25 1,750 480 3 60 CENTRIFUGAL P MODELEf3AO95 -1 TYPE LF, END SUCTION SIZE 6x8x9.5 CHILLER (CH) SCHEDULE MARK NUMBER TYPE CAPACPL TONS EVAPORATOR CONDENSER POWER CONSUMPTION KW /TON COMPRESSOR MOTORS MAXIMUM OPERATING WEIGHT (LBS) REMARKS FLOW GPM EWT 'F LWT 'F NO. PASS MAX PD 0 FLOW FT WTR FOULING FACTOR REFRIG. FLOW GPM EWT 'F LWT 'F MAX PD @ FLOW FT WTR FOULING FACTOR % CAPACITY POWER CARACTERISTICS 5 10 20 40 60 80 100 MAX. KW VOLTS PHASE HZ CH -1 RECIPROCATING 200 512 47.9 38 1 23.1 .0005 R -22 600 82 91.9 18.7 .0005 60 460 60 1 .89 159 480 3 60 TRANS CENTRAVAC MODEL #CVHE 20 CH -2 RECIPROCATING 200 512 47.9 38 1 23.1 .0005 R -22 600 82 91.9 18.7 .0005 ON 159 480 3 60 TRANE CENTRAVAC MODEL #CVHE 20 CH -3 RECIPROCATING 500 1221 48 .38 1 29.9 .0005 R -22 1500 82 92 24.2 .0005 361 480 3 60 TRANE CENTRAVAC MODEL #CVHE 50 COOLING TOWER (CT) SCHEDULE MARK NUMBER GPM EAT •F LWT °F AMBIENT AIR FANS SUMP HEATER REMARKS °F DB 'F WB NO. HP VOLTS PHASE HERTZ NO. KW VOLTS PHASE HERTZ CT -1 CT-2 600 60� 92 9 8 82 - 72 1 30 30 480 480 3 60 •0 2 3 460 3 60 FURN. W /FAN DISCH. DAMPER, ELECTRIC DAMPER CONTROLS AND DISCH. HOOD 2 3 44Jw3 ~ 60 I • • ° "' ` 1. - ' 1 ' P CT D: P ' 0 ' • " . k D CT - 3 1500 92 82 60 460 60 1 7 460 3 60 BAC MOOED VT1 -N395- X• 0. N 1W • WI H BAL I:O't CORROSION O ., EL_ . A T2, ELEC. WTR LEVEL CONTROL PKG, AND VARIABLE FREQUENCY DRIVE ��"..-_ /,--,__ J` CHEMICAL FEED POT (CFP) SCHEDULE MARK NUMBER LOCATION SERVICE CAPACITY GALLONS MAX. WORKING PRESS. (PSIG) INLET/ OUTLET OVERALL DIMENSION (INCHES) APPROX. WEIGHT LBS. (OPERATING) REMARKS DESIGN WORK ET -1 CHILLED WTR 120 GAL 120 GAL 125 30 ASME BELL & GOSSETT, OR APPROVED . PRESSURIZED TANK VESSEL COMPRESSION (CPT) TANK SCHEDULE MARK NUMBER SERVICE CAPACITY GALLONS DIAMETER xLENGTH PRESS. PSIG CODE STAMP REMARKS TANK VOL. ACCEPTANCE VOL. DESIGN WORK ET -1 CHILLED WTR 120 GAL 120 GAL 125 30 ASME BELL & GOSSETT, OR APPROVED . PRESSURIZED TANK SYM A INSTALL COOLING TOWER REVISION J #703542 - 00 BY CH APPROVED DATE 8.13.01 SYM REVISION APPROVED DATE ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CH CHECKED N HECKED APPROVED APPROVED DATE 07.20.01 SUBTITLE TITLE MECHANICAL MASTER EQUIPMENT LIST SCHEDULE BUILDING 9 -102 M01 -165 D.0 CURRENT REVISION SHEET APR 18 2002 SYMBOL M1a RECENEO CrtV OF NKWI�A PERMIT CENTER DATE JOB ND. J #703542 -00 COMP NO. DWG No. 9 -1U2 -IMO 8.13.01 @I /NLET ®46" AFF DUCT CLOSE REVISION BY ' APPROVED I DATE SYM CHILLED WATER ENLARGE PLAN SCALE: 1/4 " =1'- REVISION BY APPROVED DATE ® O DEL #120SQN -B 60 /60 20.4 NT FAN THRU WALL 45 W /BIRD SCREEN 20.65 -UP CHWR CHWS 9 -101 ANNEX. PIPE AIL M450 M509 20.9 HAWING ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CHECKED LNO CHECKED APPROVED APPROVED DATE SUBTITLE TITLE ENLARGE PLAN BUILDING 9-102 MO1 -165 MECHANICAL MASTER COL. Aa -Bb %20.4 -20.9 D.0 LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES E X131 CURRENT REVISION SHEET M450 JOB NO DWG NO APR 8 2002 SYMBOL T -102 -0450 PERMIT CENTER DATE COMP N0. . (TYP) 2' -7" 1O' -2" _.:� 2" •.L1L1YV COOK FAN M 1 -1/2 HP, 4 1650 CRM, 1 1 -1/2" TO 2ND FLR C1 n Al I I 3'_2" I n 1 II ■ w 5 M45 MEW V . II 1 -1/z" ill w `; CHILLER — O A R TFAB E — - L � i— CHILLER lUilUUU ®I.]® ` /► M450.0 CHILLER =__ •,' II �1 • 2" CW FROM 6" RISER FOR TYP WATER PIPE SUPPORT SEE DETAIL © 01- - I 1111 � �!, _ TO 1 -i R /FD 2 UP " I III ' '� _ COOLING I J ■ M450 M509 1 -1/2" PW UP FROM COOLING TOWER MAKE - UP 9 RISER SUPPORTS SEE DETAILQ 0_ II ■ • 1 -1/2" I 1111111111 , pr • • ' � III -I� I�'J\ ' HI L . 1/2" CHWS —mi _ --IY• � �1 AIR VENT SEE DETAIL 10 6" CCS ∎ 2 1/2" I DN TO 3/ RV AND WTR R E FOR CHW UP, . SEE FLOW .RAM M450 v1507 6" CCS M450 M507 FLOW SWITCH m 4 S�1CG �Z � � 1 , - - -- :v;� 1 SEE DETAIL M450 M507 u,.. _� � i �i�� of _ , u1= r ` �S- - 11R nr -iv �E 1�_ ►1_ l.�p� 1I � II f : � i=r° •_ M455OR 6" CHW AUTO AIR VENT o = y N R �� i n i OI „ 1 r SEE DETAIL Q ' (4 PUMPS) M450 M507 P -9 IN P -10 NEW BEAM FOR PIPE SE (TYP 3' DRAIN LINE TRENCH I SZ 4©1:41A W. ► V i fi �37 > =s • �i' 11ICCHrrik• IliIiil�p • =no � I� _ � i N 1 =C nimmnann, , ==: CGS° =n - N n nim 3/4" CHW P 4 g 600 GPM SO R - _ _ JL- - - - - -- �_ SEE E DETAIL ____ t. 1500 GPM 600 GPM MAKE -UP ET Tim A = n 10" BYPASS M450 M509 1_1/2" IW .� s 9 •-1" 1 -1 /4 " i � FLR DRN 3 CHEMICAL - 1 " E EXP. TANK �N f AIR I SEPARATOR I r 1 10 I BIOCIDE & INHIBITOR ��J �� FEED STORAGE DRUMS p p/ SEE DETAIL ® P -7A ®� � 1 i gi � 1 MD 10 TO - FOR TYP. CHWS &R SUPPORTS SEE DE M450 M507 1 536 GPM �_I `� I F ". To I L — OR DRYER l ot.. _ ilk* Ld I 11M • � O J 0 52 0 O + P -7B STD -BE 77 O - � 2 0 I 1536 GPM M I) 1 I IX �c ORROSION COUPON BASKET M450 M517 RACK, 2' -9" _ — _ -- - TEST SEE DETAIL ® STRAINER, TYP. M450 M507 - 6' -7" r 6 . -7 " 6 ' -7 ,. _ REF REF REF .. � - 'Q OF MEZZ. FLR F @I /NLET ®46" AFF DUCT CLOSE REVISION BY ' APPROVED I DATE SYM CHILLED WATER ENLARGE PLAN SCALE: 1/4 " =1'- REVISION BY APPROVED DATE ® O DEL #120SQN -B 60 /60 20.4 NT FAN THRU WALL 45 W /BIRD SCREEN 20.65 -UP CHWR CHWS 9 -101 ANNEX. PIPE AIL M450 M509 20.9 HAWING ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CHECKED LNO CHECKED APPROVED APPROVED DATE SUBTITLE TITLE ENLARGE PLAN BUILDING 9-102 MO1 -165 MECHANICAL MASTER COL. Aa -Bb %20.4 -20.9 D.0 LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES E X131 CURRENT REVISION SHEET M450 JOB NO DWG NO APR 8 2002 SYMBOL T -102 -0450 PERMIT CENTER DATE COMP N0. 10' CHWS B.O.P. EL 27' -3" 27' -3" B.O.P STRAINER REMOVAL BUTTERFLY VALVE(TYP) NON -SLAM CHECK VALVE(TYP) P -7B (STANDBY) 10" CCS 3/4" CHEM. 4 FEED (SEE DIAL. THIS SAT.) 6" CCR B.O.P. EL 45-3" FOR FASTENING PIPING SUPPORTS TO BEAMS USE GRINNELL FIG. 87 "C" CLAMP W /RETAINING CLIP (PIPING. 6" OR LESS) FOR TYPICAL CONDENSER 1' -0" WATER PIPING SUPPORT SEE DETAIL M507 M509 ' I II/ 27' -3" 2" VENT AIR SEPARATOR "7= %10111DMIA. ' -3" B.O.P. OZfiZM M d 2.5=9" C B nn 6 "CCR 2 VENT VENT SUPPOR � 6 "CCS SEE DETAIL MME STARTER PANEL F.F. EL 32' -6" F.F. EL 15 -6 5-6" P -7A 1" GRISWOLD BLEED VALVE MDL 416 -S1' 3/4" SCH 80 PVC REVSION PIPE BRACE SEE SECTION FOR PIPING N 2ND LEVEL SEE DWG M -2 - EXPANSION TANK SECTION SCALE: 1/4 " =1' -0" M507 10" CCU COMBINATION FLOW SWITCH FLOW SIGHT AND BACK CHECK VALVE 1/4' BALLCOCK CHEMICAL FEED PUMPS 3/8" PLASTIC TUBING / FLR. BY APPROVED 20.65 M450 M507 DATE 1" CAPPED BLEED OFF LINE rl 3' FUNNEL FLR DRAIN N RUPTURE DIS _ NT SEE DETAIL ( 4\ SEE DETAIL M5C77IM509 5;M BIOCIDE & INHIBITOR STORAGE DRUMS CHEMICAL FEED PIPING DIAGRAM 13 REVISION SCALE: NONE M450 14507 M507 CORROSION COUPON TEST RACK (TYP) BY 20.4 APPROVED 6" CCR 1" TO FUNNEL FLOOR DRAIN DATE 30" TO 240" THERMOMETER W /8" STEM 3/4" EXTENSIO THERMOWEL 1/4" PETE'S PLUG 1/4" THREADOLEi x 10" HD GROOVED PIPE COUPLING 10 "0 RISER 10" BUTTERFLY VALVE W /GEAR OPERATOR VICTAULIC 0 -100 PSI GAUGE 1/4' GAUGE COCK Ni 1/4" THREDOLET x 10" HDR 10 "EXPANSION JOINT iiisirezzEzArda. BELL & GOSSETT SUCTION. DIFFUSER 10" SYSTEM SIDE, 8" P SIDE SUPPORT UMP LEG W/ PUMP INSTALLATION DETAIL SCALE: NONE M450 M5 707 3/4" THREADOLET x 10" HDR INSULATION 10" CHWS /CHWR 60" AFF 54" AFF CHWS /CHWR RISER DET SCALE: 1 1/2"-=1' -0" 1 -1/4" THREADOLET z 10" HDR PLUG UNUSED OUTLETS 45" AFF 41" AFF 37" AFF M507 BEAM CLAMP, GRINNELL FIG. 229 3/4 "0 THD ROD L 3x3x1/4 7/8"0 3 HOLES ON 1 -3/4" GAGE EYE NUT 5/8 "4 BOLT & NUT 3/4"% HOLE RISER CLAMP RISER SUPPORT DETAIL n SCALE: 1"H ' -0" 5O 1 M4507 APPROVED BY 10" TRIPLE DUTY VALVE BELL & GOSSETT 0 -100 PSI GAUGE 1/4" GAUGE COCK 1/4" THREDOLET x 10" HDR 10" EXPANSION JOINT 10 "x6" CONC. REDUCER DRAIN 1- 1/4"x3/4" BUSHING 3/4 NIPPLE 3/4" 900 ELL 3/4" NIPPLE 3/4" BALL VALVE 3/4" MNPTx3 /4 "MALE HOSE THD 3/4" FEMALE HOSE THD CAP 1 PUMP MOUNTING PAD- SEE STRUCT DWG 30" TO 240" THERMOMETER W /8" STEM 3/4" EXTENSION THERMOWELL 1/4" PETE'S PLUG 1/4" THREAD x 10" HDR ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. 10 "CCR 10 "CHWS SECTION DATE DRAWN CHECKED CHECKED APPROVED APPROVED DATE CHILLER SUBTITLE TITLE 3/4" THREADOLET x 10" HDR 10" CHWS /CHWR 60" AFF 54" AFF 45" AFF 37" AFF CCS /CCR RISER DET SCALE: 1 1/2 " =1' -0" M507 10 "CCS SEE DET B SCALE: 1/4 " =1' -0" M450 M507 POWER STRUT PIPE SUPPORT BRIDGE RO I GE A�� TviANS AND ATTACH TO FLOOR W/ 1/2 HILTI KWIK BOLT SEE VET M450 M507 RUPTURE DISK 1 -1/4" THREADOLET x 10" HDR PLUG UNUSED OUTLETS 2ND FLR EL. 32' -6" 10'CHWR SEE DET M507 10" FLOW CONTROL VALVE 1ST FLR EL 15' - MAKE UP NIPPLE TO THREADED FLANGE HAND TIGHT Oi'I Y NOTE: INSTALL AS SHOWN ABOVE ON ONE NEW 500 TON CHILLER AND RETRO FIT TWO EXISTING CHILLERS. 10 "x8" CONC. REDUCER (TYP OF 4) SECTIONS AND DIAGRAM BUILDING 9- 102 -M507 MECHANICAL MASTER COL. 20.65 -20.1 FLOW SWITCH UNION EXPANSION JOINT 2" TEE 1/4" 0.D. COPPER CONDENSATE DRAIN AWAY FROM MACHINE DANGER DO NOT REWORK RUPTURE DISK CONNECTIONS WHILE MACHINE IS OPERATING. RUPTURE DISK VENT DETAIL SCALE: 1 1/2 " =1' -0" M507 AIR VENT - I 1 /2 Y 10 "0 VALVE E AUTO AIR VENT DET. SCALE: NONE 2 "x1" BUSHING M450 M507 FLOW SWITCH DETAIL 1,1 SCALE: NONE M450 M507 DISK VENT CHANNEL STRUT - EXFiRED APR 18 2002 I VENT SUPPORT DET. 12 SCALE: NONE M507 M01-165 D.0 CURRENT REVISION SYMBOL SHEET JOB ND. M507 DWG NO. CO OF TOilLik APRCPED OCT 18 211 ,S EU PIPE CHANNEL U" FITTING WING FITTING HILTI KWIK -BOLT 9- 102 -M507 REC�rvEo ;:ITY OF TL'K�vtA DATE PERMIT CENTER COMP NO. 1" CAPPED BLE D LINE 10' CHWS B.O.P. EL 27' -3" 27' -3" B.O.P STRAINER REMOVAL BUTTERFLY VALVE(TYP) NON -SLAM CHECK VALVE(TYP) P -7B (STANDBY) 10" CCS 3/4" CHEM. 4 FEED (SEE DIAL. THIS SAT.) 6" CCR B.O.P. EL 45-3" FOR FASTENING PIPING SUPPORTS TO BEAMS USE GRINNELL FIG. 87 "C" CLAMP W /RETAINING CLIP (PIPING. 6" OR LESS) FOR TYPICAL CONDENSER 1' -0" WATER PIPING SUPPORT SEE DETAIL M507 M509 ' I II/ 27' -3" 2" VENT AIR SEPARATOR "7= %10111DMIA. ' -3" B.O.P. OZfiZM M d 2.5=9" C B nn 6 "CCR 2 VENT VENT SUPPOR � 6 "CCS SEE DETAIL MME STARTER PANEL F.F. EL 32' -6" F.F. EL 15 -6 5-6" P -7A 1" GRISWOLD BLEED VALVE MDL 416 -S1' 3/4" SCH 80 PVC REVSION PIPE BRACE SEE SECTION FOR PIPING N 2ND LEVEL SEE DWG M -2 - EXPANSION TANK SECTION SCALE: 1/4 " =1' -0" M507 10" CCU COMBINATION FLOW SWITCH FLOW SIGHT AND BACK CHECK VALVE 1/4' BALLCOCK CHEMICAL FEED PUMPS 3/8" PLASTIC TUBING / FLR. BY APPROVED 20.65 M450 M507 DATE 1" CAPPED BLEED OFF LINE rl 3' FUNNEL FLR DRAIN N RUPTURE DIS _ NT SEE DETAIL ( 4\ SEE DETAIL M5C77IM509 5;M BIOCIDE & INHIBITOR STORAGE DRUMS CHEMICAL FEED PIPING DIAGRAM 13 REVISION SCALE: NONE M450 14507 M507 CORROSION COUPON TEST RACK (TYP) BY 20.4 APPROVED 6" CCR 1" TO FUNNEL FLOOR DRAIN DATE 30" TO 240" THERMOMETER W /8" STEM 3/4" EXTENSIO THERMOWEL 1/4" PETE'S PLUG 1/4" THREADOLEi x 10" HD GROOVED PIPE COUPLING 10 "0 RISER 10" BUTTERFLY VALVE W /GEAR OPERATOR VICTAULIC 0 -100 PSI GAUGE 1/4' GAUGE COCK Ni 1/4" THREDOLET x 10" HDR 10 "EXPANSION JOINT iiisirezzEzArda. BELL & GOSSETT SUCTION. DIFFUSER 10" SYSTEM SIDE, 8" P SIDE SUPPORT UMP LEG W/ PUMP INSTALLATION DETAIL SCALE: NONE M450 M5 707 3/4" THREADOLET x 10" HDR INSULATION 10" CHWS /CHWR 60" AFF 54" AFF CHWS /CHWR RISER DET SCALE: 1 1/2"-=1' -0" 1 -1/4" THREADOLET z 10" HDR PLUG UNUSED OUTLETS 45" AFF 41" AFF 37" AFF M507 BEAM CLAMP, GRINNELL FIG. 229 3/4 "0 THD ROD L 3x3x1/4 7/8"0 3 HOLES ON 1 -3/4" GAGE EYE NUT 5/8 "4 BOLT & NUT 3/4"% HOLE RISER CLAMP RISER SUPPORT DETAIL n SCALE: 1"H ' -0" 5O 1 M4507 APPROVED BY 10" TRIPLE DUTY VALVE BELL & GOSSETT 0 -100 PSI GAUGE 1/4" GAUGE COCK 1/4" THREDOLET x 10" HDR 10" EXPANSION JOINT 10 "x6" CONC. REDUCER DRAIN 1- 1/4"x3/4" BUSHING 3/4 NIPPLE 3/4" 900 ELL 3/4" NIPPLE 3/4" BALL VALVE 3/4" MNPTx3 /4 "MALE HOSE THD 3/4" FEMALE HOSE THD CAP 1 PUMP MOUNTING PAD- SEE STRUCT DWG 30" TO 240" THERMOMETER W /8" STEM 3/4" EXTENSION THERMOWELL 1/4" PETE'S PLUG 1/4" THREAD x 10" HDR ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. 10 "CCR 10 "CHWS SECTION DATE DRAWN CHECKED CHECKED APPROVED APPROVED DATE CHILLER SUBTITLE TITLE 3/4" THREADOLET x 10" HDR 10" CHWS /CHWR 60" AFF 54" AFF 45" AFF 37" AFF CCS /CCR RISER DET SCALE: 1 1/2 " =1' -0" M507 10 "CCS SEE DET B SCALE: 1/4 " =1' -0" M450 M507 POWER STRUT PIPE SUPPORT BRIDGE RO I GE A�� TviANS AND ATTACH TO FLOOR W/ 1/2 HILTI KWIK BOLT SEE VET M450 M507 RUPTURE DISK 1 -1/4" THREADOLET x 10" HDR PLUG UNUSED OUTLETS 2ND FLR EL. 32' -6" 10'CHWR SEE DET M507 10" FLOW CONTROL VALVE 1ST FLR EL 15' - MAKE UP NIPPLE TO THREADED FLANGE HAND TIGHT Oi'I Y NOTE: INSTALL AS SHOWN ABOVE ON ONE NEW 500 TON CHILLER AND RETRO FIT TWO EXISTING CHILLERS. 10 "x8" CONC. REDUCER (TYP OF 4) SECTIONS AND DIAGRAM BUILDING 9- 102 -M507 MECHANICAL MASTER COL. 20.65 -20.1 FLOW SWITCH UNION EXPANSION JOINT 2" TEE 1/4" 0.D. COPPER CONDENSATE DRAIN AWAY FROM MACHINE DANGER DO NOT REWORK RUPTURE DISK CONNECTIONS WHILE MACHINE IS OPERATING. RUPTURE DISK VENT DETAIL SCALE: 1 1/2 " =1' -0" M507 AIR VENT - I 1 /2 Y 10 "0 VALVE E AUTO AIR VENT DET. SCALE: NONE 2 "x1" BUSHING M450 M507 FLOW SWITCH DETAIL 1,1 SCALE: NONE M450 M507 DISK VENT CHANNEL STRUT - EXFiRED APR 18 2002 I VENT SUPPORT DET. 12 SCALE: NONE M507 M01-165 D.0 CURRENT REVISION SYMBOL SHEET JOB ND. M507 DWG NO. CO OF TOilLik APRCPED OCT 18 211 ,S EU PIPE CHANNEL U" FITTING WING FITTING HILTI KWIK -BOLT 9- 102 -M507 REC�rvEo ;:ITY OF TL'K�vtA DATE PERMIT CENTER COMP NO. v LNVLJ - - -.. .. -. -_ MOU'2.1_19UY 19' -9." ROOF M508 M50 _ 1 OLD 3 3' - 4" H ROOF R r l m � l 3' - 4° 9 9' -10" 9' -10" a I 4 � a 0 ' A I 4 AIM M m _om: � ��----- + +- - - - -- H VEL PIES % DRAIN (TYP. - .� 19' - 9" 9 FROM ) _ 3' -4" SULATED 3' - 4" ER o w I I D' COOLING TOWERS 309 4 D I ON ROOF -�� GT v Ai 1 � 3 I U I 6" CCR TF F i D THRU ROOF r 1 1 I I o t 1" CW I 1 ti -UP TO i 1" MAKE -UP . 11__1, i I .1 _ , ti :R CT 3 WATER TO* T I - +�� COOLING I I I ty , . • I TOWER, TYP. P ! 4 ' -0 „ j t N 2' - s" 3' DRAIN = I ROOF TYP. OF 2/ '= I THRU ROOF I I II I- FOR TYPICAL CONDENSER I N © THRU FLR WATER PIPE SUPPORT SEE DET m i7 6" CCS CS JPPORT DET. M508 M509 V MAIM n j SYM A 1 -1/2" CN 1ST FLR IN TYP CW PIPE 08 MI DEDET. 3 M50 / 18 PA` 1-1/2" MAI<I COOLING TOW 10" CCS THRU ROOF 10" CCS /R I SEE RISER S INSTALL COOLING TOWER M50 509 N (2) 7/8" 0 HOLES FOR U- BOLTS? SECTION 22 REDRAWN TO ACRD FROM 109- 102 - 4107 -MB SCALE: 1/2"= 1' -0" M508 REVISION J4703542 - 00 BY KB CH PARTIAL 2ND FLOOR PLAN SCALE: 1/4 " =1' -0" (2) 16 GA. GALV. SHIELDS 180 EA ROLLED TO RADIOS TO FIT 0.D. OF PIPE APPROVED CH (2) 1/2" S.S BANDS DATE 7.25.01 8.13.01 ly 11 SECTION SCALE: 1 /2 " =1' -0" 1/2' 6 "CCS '-W6x15.5 \\- INSULATION & ROOFING METAL DECK M507/M5081M508 REVISION COOLING TOWER ROOF(ELEV. VARIES) THRU 2ND FLR TO j FUNNEL FLR DRAIN BY Bb APPROVED DATE 20.4 20 NOTE ALL WATER PIPING ABOVE ROOF TO BE INSULATED HEAT TRACED AND COVERED WITH 20 MIL PVC JACKET INCLUDING DRAI BETWEEN TOWEL DRAIN VALVES, 65 FL LE ( 10" CCS DI THRU ROOF 1" SOLENOID 1 VALVE, HEAT TRACE 1 -1/2" BYPASS - -H1 1 -1 cw 1 -1/2" MAKE -UP WTI" TO COOLING TOWERS • 10" CCS 10" FLOW CONTROL VALVE 1500 GPM 10" CHWR 10" CHWS P -10 ' 1 -1/2" ET r - EZB%I I HiF P-6 1500 GP I' Ct CT -2 10" CCR P -3 SEC. 1221GPM 0 CONDENSER EVAPORATOR] v 10" CCR UP THRU ROOF, BR E RISER SIMILAR TO SECTION t� (2) -8" TO TWR 3/4: SOLENOID 1" BYPASS - 3" DRAIN 1 -1/2" 1;(1- � P -9 SECONDARY 1221GPM vI 10 6" CCR —�� k n n: 6" CCS- - 9 - - FLOW SWITCH 0 } PP5 600 GPM PARTIAL ROOF PLAN SCALE: 1 /4 " =1' -0" CT -2 6" CHWR 6" CHWS P -2 SECONDARY 512 GPM 0 TRACED & WEATER -PROOF METAL JACKETED ABOVE ROOF, TYP. OF 2 0 CHWR CHWS 3/4" SOLENOID 1" BYPASS . '9 v 6" CCR —�� 6" CGS- CHILLED WATER PIPING DIAGRAM 22 SCALE: NONE APPROVED M450 M508 PP4 600 GPM 0 WATER TREATMENT WATER, INSULATED, HEAT TRACED AND WEATER -PROOF METAL .!ACKETiEDD ABOVE ROOF TYP.' OF 2 6x5 REDUCER TYP @ COND &EVAP CONDENSER v EVAPORATOR I 6" CHWR �6 "- CHWS P -1 SECONDARY 512 GPM 10" 10" AIR SEPARATOR �T RO T �. SEE PARTIAL DIAGRAM ON M -507 FOR MAKE -UP & PURGE CONDENSER COOLING SYSTEM ROOF �.4 DRAIN (REF.) R, INSULATED HEAT D & WEATER -PROOF JACKETED ABOVE ROOF SIMILAR TO IN "A" THIS DWG. COMPRESSI TANK FROM MAKE -UP SYSTEM \- -3/4" ASS BY -P I� I (� l p� 9 } P- 7A (PRIMARY) 1536 GPM T I CHWR - B CHWS TO PURGE CONDENSER CONSTRUCTION NOTES C> INSTALL EXISTING 10" CCS TO NEW COOLING TOWER. USE VIC. CONCENTRIC REDUCERS TO ATTACH TO 8" OUTLET ON NEW TOWER. INSTALL EXISTING 10" CCR TO NEW COOLING TOWR. USE VIC. CONCENTRIC REDUCER TO ATTACH TO 8" OUTLET ON NEW TOWER. INSTALL EXISTING 1" MAKE -UP WATER LINE TO NEW TOWER. REMOVE EXISTING SOLINOID VALVE AND INSTALL NEW SOLINOID VALVE SUPPLY WITH TOWER. ® INSTALL OVERFLOW DRAIN AND DRAIN FROM NEW TOWER TO EXISTING DRAIN REPLACE ALL PVC DRAIN PIPING BACK TO TOWER 2 TEE. INSTALL LEVEL SENSOR AND LEVEL SENSOR CONTROL BOX SUPPLIED WITH TOWER. P -7B (STANDBY) 1536 GPM MO1 -165 EXP IRED APR 182002 REQIVED ::IT,'nF TUtN ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS .APPROVED APPROVED BY DEP, DATE DRAWN K.BUN CHECKED APPROVED DATE CHECKED C.HARRAH SUBTITLE PARTIAL PLANS, SECTION, AND DIAGRAM TITLE BUILDING 9- 102 -M508 CURRENT REVISION 1 SYMBOL A SHEET M508 JOB NO J #703542 -00 DATE 8.13.01 COMP N0. SYM A 1 -1/2" CN 1ST FLR IN TYP CW PIPE 08 MI DEDET. 3 M50 / 18 PA` 1-1/2" MAI<I COOLING TOW 10" CCS THRU ROOF 10" CCS /R I SEE RISER S INSTALL COOLING TOWER M50 509 N (2) 7/8" 0 HOLES FOR U- BOLTS? SECTION 22 REDRAWN TO ACRD FROM 109- 102 - 4107 -MB SCALE: 1/2"= 1' -0" M508 REVISION J4703542 - 00 BY KB CH PARTIAL 2ND FLOOR PLAN SCALE: 1/4 " =1' -0" (2) 16 GA. GALV. SHIELDS 180 EA ROLLED TO RADIOS TO FIT 0.D. OF PIPE APPROVED CH (2) 1/2" S.S BANDS DATE 7.25.01 8.13.01 ly 11 SECTION SCALE: 1 /2 " =1' -0" 1/2' 6 "CCS '-W6x15.5 \\- INSULATION & ROOFING METAL DECK M507/M5081M508 REVISION COOLING TOWER ROOF(ELEV. VARIES) THRU 2ND FLR TO j FUNNEL FLR DRAIN BY Bb APPROVED DATE 20.4 20 NOTE ALL WATER PIPING ABOVE ROOF TO BE INSULATED HEAT TRACED AND COVERED WITH 20 MIL PVC JACKET INCLUDING DRAI BETWEEN TOWEL DRAIN VALVES, 65 FL LE ( 10" CCS DI THRU ROOF 1" SOLENOID 1 VALVE, HEAT TRACE 1 -1/2" BYPASS - -H1 1 -1 cw 1 -1/2" MAKE -UP WTI" TO COOLING TOWERS • 10" CCS 10" FLOW CONTROL VALVE 1500 GPM 10" CHWR 10" CHWS P -10 ' 1 -1/2" ET r - EZB%I I HiF P-6 1500 GP I' Ct CT -2 10" CCR P -3 SEC. 1221GPM 0 CONDENSER EVAPORATOR] v 10" CCR UP THRU ROOF, BR E RISER SIMILAR TO SECTION t� (2) -8" TO TWR 3/4: SOLENOID 1" BYPASS - 3" DRAIN 1 -1/2" 1;(1- � P -9 SECONDARY 1221GPM vI 10 6" CCR —�� k n n: 6" CCS- - 9 - - FLOW SWITCH 0 } PP5 600 GPM PARTIAL ROOF PLAN SCALE: 1 /4 " =1' -0" CT -2 6" CHWR 6" CHWS P -2 SECONDARY 512 GPM 0 TRACED & WEATER -PROOF METAL JACKETED ABOVE ROOF, TYP. OF 2 0 CHWR CHWS 3/4" SOLENOID 1" BYPASS . '9 v 6" CCR —�� 6" CGS- CHILLED WATER PIPING DIAGRAM 22 SCALE: NONE APPROVED M450 M508 PP4 600 GPM 0 WATER TREATMENT WATER, INSULATED, HEAT TRACED AND WEATER -PROOF METAL .!ACKETiEDD ABOVE ROOF TYP.' OF 2 6x5 REDUCER TYP @ COND &EVAP CONDENSER v EVAPORATOR I 6" CHWR �6 "- CHWS P -1 SECONDARY 512 GPM 10" 10" AIR SEPARATOR �T RO T �. SEE PARTIAL DIAGRAM ON M -507 FOR MAKE -UP & PURGE CONDENSER COOLING SYSTEM ROOF �.4 DRAIN (REF.) R, INSULATED HEAT D & WEATER -PROOF JACKETED ABOVE ROOF SIMILAR TO IN "A" THIS DWG. COMPRESSI TANK FROM MAKE -UP SYSTEM \- -3/4" ASS BY -P I� I (� l p� 9 } P- 7A (PRIMARY) 1536 GPM T I CHWR - B CHWS TO PURGE CONDENSER CONSTRUCTION NOTES C> INSTALL EXISTING 10" CCS TO NEW COOLING TOWER. USE VIC. CONCENTRIC REDUCERS TO ATTACH TO 8" OUTLET ON NEW TOWER. INSTALL EXISTING 10" CCR TO NEW COOLING TOWR. USE VIC. CONCENTRIC REDUCER TO ATTACH TO 8" OUTLET ON NEW TOWER. INSTALL EXISTING 1" MAKE -UP WATER LINE TO NEW TOWER. REMOVE EXISTING SOLINOID VALVE AND INSTALL NEW SOLINOID VALVE SUPPLY WITH TOWER. ® INSTALL OVERFLOW DRAIN AND DRAIN FROM NEW TOWER TO EXISTING DRAIN REPLACE ALL PVC DRAIN PIPING BACK TO TOWER 2 TEE. INSTALL LEVEL SENSOR AND LEVEL SENSOR CONTROL BOX SUPPLIED WITH TOWER. P -7B (STANDBY) 1536 GPM MO1 -165 EXP IRED APR 182002 REQIVED ::IT,'nF TUtN ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS .APPROVED APPROVED BY DEP, DATE DRAWN K.BUN CHECKED APPROVED DATE CHECKED C.HARRAH SUBTITLE PARTIAL PLANS, SECTION, AND DIAGRAM TITLE BUILDING 9- 102 -M508 CURRENT REVISION 1 SYMBOL A SHEET M508 JOB NO J #703542 -00 DATE 8.13.01 COMP N0. A CHILLED WATER PIPING SUPPORT 2" SUMP DRAIN ON SIDE INSTALL COOLING TOWER DETAIL SCALE: NONE J\ 1/4" E DETAIL SCALE: NONE REVISION PROTECTION SADDLE / GRINNELL FIG.162 / OR EQUAL W /STEEL BANDING TO PIPE EACH END OF SADDLE BAND -IT OR EQUAL REDRAWN TO ACAD FROM 109 -102- 4101 -M13 /FOR 10" CHWS /R USE / GRINNELL FIG 292 SIZE 2 BEAM CLAMPS SEE DET M509 GRINNELL FIG. 181 PIPE ROLL & YOKE CHWR /CHWS C3x4.1 OR PS -200 POWER STRUT ACdESS VERFLOW 1. v 3 "DRAIN • 2ND FLOOR OR ROOF 3" MPT OVERFLOW SOUTH ELEVATION n SCALE: 1/2 " =1' -0" M508 M509 I J #703542 -00 ALTERNATE CHWS /R SUPPORT 1" FPT MAKE UP GRINNELL FIG. 261 /RISER PIPE CLAMP x.1 1 /4 V < TYP 2ND FLOOR BY KB CH — GRINNELL FIG. 175 ROLLER CHAIR M450 M509 12" BLACK STEEL PIPE 10 "CWS /R 4\ M508 M509 APPROVED CA PROTECTION SADDLE GRINNELL FIG.162 OR EQUAL W /STEEL BANDING TO PIPE EACH END OF SADDLE BAND -IT OR EQUAL ��- OLD COOLING TOWER NEW COOLING TOWER DATE 7.25.01 8.13!01 1/4 1/4 GRINNELL FIG. 137 U -BOLT C6x 1 D.5 10" SHORT RADIUS 90' ELBOW SECTION SCALE: 1 " =1' -0" 3/16 7/8" THRD ROD DN TO 10" PIPE GRINNELL FIG. 260 ADJ. CLEVI S DETAIL SCALE: NONE REVISION r ak h ii 6 DETAIL SCALE: NONE 10" 7/8" ROD UP TO GRINNELL FIG. 292, SIZE 2 BEAM CLAMP SPANNING BETWEEN ST'UCTURAL BEAMS, SEE DETAIL Li i C CONDENSATE WATER PIPING SUPPORT M508 M509 BY BEAM W8x10 M509 2 M08M09 L3x3x5 /16x0 -5 ONE SIZE ONLY 3/16 3/16 5 M450 M509 APPROVED GRINNELL FIG. 269 ADJ. RING DATE OIL COOLER & FILTER DETAIL SCALE: NONE CHILLED WTR PIPING TO OIL COOLER & PURGE CONDENSER FROM VALVED STUB -OUTS 1/2" PURGE ANDENSER CH -3 COLD WATER PIPING SUPPORT EXPANSION TANK (REF) 1" AIRTROL TANK FITTING, B &G "ATFL" BECOUPLER BY -PASS (REF) AIR SEPARATOR (REF) SEE ALSO CHILLED WATER PIPING DIAGRAM, SHT M507 T1 F— CHWR 1" /2" r GRINNELL FIG. 260 ADJ. CLEVIS lI T T U r CH -2 TAPE WRAP 1' -0" OC. GRINNELL FIG. 167 PROTECTION SHIELD e M450/M5O81M509 TO PURGE CONDENSER 1" 1/2" 3 PURGE • PURGE CONDENSER ,.,�, CONDENSER IW —1 (PI • IM 1 " 3/4" HOSE BIBBS 1.,, TO COOLING TOWERS FOR INITIAL �' WATER FILL 1 _ — M I—• 3/4 "CHILLED WATER 9 1 MAKE -UP LINE P -78 (STANDBY) CH- 3/4" HOSE BIBB (TYP) 10" PIPE -PITCH = 7" 8" PIPE -PITCH = 5 1/2" 1 1/2" PIPE - STRAIGHT PITCH HEAT TRACE DETAIL n SCALE: NONE M508 M509 / II..., 2 "x2 "x1/4" ANGLE H 1/4" THK. STL. / 3" FLR. PLATE SECURE r DRAIN W/ W/4 - 3/8 "0 U. FUNNEL EXP. BOLTS 1 4 TYP. CHWR B CHWS DETAIL SCALE: NONE PULSE WATER METER INSTALLATION 15WS (STAND -BY COOLING) 3/4" IWS PARTIAL DIAGRAM, MAKE - UP ASSEMBLY AND PURGE CONDENSER COOLING SYSTEM SCALE: NONE 3" COOLING TOWER DRAIN UP TO ROOF CHILLED WATER LOOP MAKE -UP INSTALLATION ® COL D/2 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K.BUN CHECKED C.HARRAH NOINEEH CHECKED APPROVED DATE SUBTITLE TITLE DIAGRAM AND DEATILS BUILDING 9 -102 CURRENT REVISION SHEET M509 JOB NO 703542 -00 SYMBOL A DATE 8.13.01 COMP NO. APPROVED PIPE CLAMP \--FLR. 4 M507 M509 IH— (PHI IH PRESSURE REGULATOR VALVE SET ® 50 PSI LEGEND GENERAL NOTES CONSTRUCTION NOTES INSTALL EXISTING 10" CCS TO NEW COOLING TOWER. USE CONCENTRIC REDUCER TO ATTACH TO 8" OUTLET ON NEW COOLING TOWER. INSTALL EXISTING 1" MAKE -UP WATER LINE TO NEW TOWER. REMOVE EXISTING SOLINOID VALVE AND INSTALL NEW SOLINOID VALVE SUPPLIED WITH TOWER. INSTALL OVERFLOW DRAIN FROM TOWER TO EXISTING DRIAN. REPLACE ALL PVC DRAIN PIPING BACK TO TOWER 2 TEE. ® INSTALL DRAIN FROM TOWER TO EXISTING DRIAN. REPLACE ALL PVC DRAIN PIPING AND VALVE. HEAT TRACE CCS &R PIPING AND 1 -1/2 MAKE -UP WATER PIPING ABOVE ROOF. SEE DETAIL M508 M509 11.7•41 APR 1 8 2002 101 -16 CO Rem Cm CFTU ARA PERMIT CENTER SEQUENCE OF OPERATION DAMPER OPEN 5TARTER ENERGIZED STARTER NOT ENERGIZE aS FS I F52, F53, F54 S O FS], F53 FS 2, F54 - 7 5 F52, F53 F5 I, P54 100 F52, F54 Fs 1, FS 3 SYM INTEP,NAL WIP 51 wN FOPS F+EF. ONLY. 1 —� G Q NTP, OL.t =,'C PENN A5OA5A-3 REVISION — A -}- 6_0_ HI HZ F rnE c c „ GONTRUL 7C )<I 12Dv - ><Z PEVILE PHL. (REAP - VIEW) ✓ 1 I 3 z5 pjP,OWN (7,4MPSP A.G'TUA.TOF°i "AI" 17A.MPEP "A.Z° : PENN MSOJAC ORLUIT G156oNNECT DEvIGLa _ 5 - 7 q 11 L TR Z TL T • D — io L. J Io R11T0 1 1 fug H.O.P. 5W I ,ND W 17A W I A. SIZE 3 STa.FRT�P, F=OR 40 HP' FAN MGG -4 / CDC W7A GOO LIN( TOWERR, GOI.TTP -DL. POWcA 480V ROOM= °a 0UDDO— Dp,AN6re Z4`<, Az. O 0- 0 0— f52 I - / at. Ti of 0 51�K. w / Pi51 BY AP►ROYED v�1c. w /am 5 JE REV 5 K- w/YuL�I I bI-K. ,V5LUE - - 1 SYM A J SOUTH SECTION w5A. W4A. 1 WqA >. FOR ES S W10A- WISA GOOLIN In TOWER SECTION " A:I GoOLIN6, TOWET, —_._. SECT1O61 - "E G.00L.IkI(sl TOW - 1= 1 .) SEaUENGE CONTROL- PIfi &IP)AM- REVISION 130 >_ FOR PS I PLACJ3 C OLIN(- 1vwl'2 "3 a 7e3$ z -tv TIMEt'. II.L SIZE 3 STARTER 'IS SE'. MIN. pSLtY To Gw ) RISE X1 HOLDER C==. Gol.rlP,ol -- RGUIT -� DEYIGE PNLkEAR view) LIRGl11'L - =- DScoNNEST W 14A_ w1 SA. WV, A BY 4/sac4 0 II 7 SIZE 1 STARTED rOR'IU HP PAN MGG - 47be , APPROVED y bw1 N. o.A 5W - ZQ HAND DATE 4 jsju At 4 1, fzi M SOUTH SECTION NORTI-I SECTION 0 4 H.P. F52 T AI 45 aL 96 o,pl'd D W13H O SRI F51 0 10 H.P. F5 3 AZ PLAN VI N.T.S. 0 4 H.P. 1 NOTE. is 5ECOND MINIMUM DELAY FOR HIGH SPEED TO LOW SPEED. N CITE 0= GUSTOMEP, CONNECTION POINT 4i= PEMUTE vEVICE F5 F I, F : FAN MOTOR STARTER HO LDING COIL LOWN SPEED. , O= (SEE MOO LEA,l7 SHLET} F5 2, F5 4 : RAN MOTOR STARTER HOLDING COIL HIGH SPEED. 51 , 53 : AUXILIARY SWITCH TO CONTROL LOW SPEED rAN f4 oTOR S.(FACTORY SE I) RATED FOR PILOT DUTY OF I25vA AT 24 ro 300 52, 54 : AUXILIARY SWITCH TO CONTROL 1-11014 SPEED FAN PAO (FACTORY SET) RATED FOR PILOT DUTY OF 125vA AT 24 To 100 VAC. 1 U ,r—F54 El AUBURN, WA. 98002 EVERETT, WA. 98201 B®E 11110 ❑ KENT, WA. 98031 FACILITIES DEPARTMENT o PORTLAND, OR. 97220 A 93 ) _ CIRCUIT 6 of )t 4 P8LbNNECr FUSE HOLDER a X1 a * XZ 4 r DEYICE PNL (PSA VIEW) 1 I tNTEP,NAL wIRIN6, - - - - I — — — SI fowN =ooS REF: 5 7 OhlLY Df f� f� fR S To 5 5 I r- 5& 10 ti IS 13 CONTROL CIRCUIT I�EI O.A � ` -- I b SW F I HAND 0 M GC - 4 / C9E APPROVED BY DEPT. ACCEPTABILITY THIS DESIGN ANDIOR SPECIFICATION IS APPROVED Z wzwA. WZIA. WZZA SI 3 STARTER POP - 4a HP FA .K SIZEJI STAR,TEi - FOR 10 1P _-.:FaN DATE 5 NORTH SECTION I GATE b• 1°1.85 En",/,,7 CHECKED "f o � � TIMCF IN SIZES . STAFti'TSP,.- (15 5 E6. MIN. DELAY 1 CLOS.5) FU 5E HOLDER X N I CONTROL XZ /` CIRCUIT X� e E TC. Nt t7EVICE P1JL -REA.R VIIE,w w18A. . W 14A.. - REmovt SUBTITLE ISGONNEGT TIMEtS PP•,oM 5128 .3 STK�iTi;R & - C�G6 C.; 10 5 - E I STA.PI,T0Ii A.% SH 6 N1 . GONN*cT CONTROL WIF�N� f11 THP,UUAAH 4 - PULE SAFETY swiTGH_ I © REMOV iRiNV DETWEEN 1t El2mINAL XI AND I . a _ p5', r OL — TIC A QS� � GIP,LU,T o , I ro 6 (6)= D15OANNEGT =ri I ° - -- DEALS — .^.-4, o lobo}— oa+o_ -- 0 i 4 r 8 10 MGG - 4/L97 NSTAA. /I¢II♦(Gi Acv SHOWt♦L s CONSTP,LJTION. NOTES REWIRE H.A.O. SW AS SHOWN. REt- OI�/Lu ' �L''M OY✓% REPL A Cc: COOLING TOWER NO. 3 CONTROL DIAGRAM FII Fr AI Nil ACTRR AZ 4 y OuD 'SeE Expig MO1 -165 tar- C" S07. O Q P ..n eF r�r LAST REVISION SHEET 1E -13 0 JOB NO. DATE 311/0 0£961 uN OMO 'ON 801' II" ■ in ._ 133HS 1...1 NOISIn3a 1SVl ZETA =10 201 -601 __._: hMfl__ %em. `J31 N 3 0 1iNa3e pry �i V11MNft1 i0 CF `3n 03 8(1', - o ' J' ? (1 i J V G3:�J ,� p OVA c Ar-nl LS N I - -)o-1 - 1.0S 3 . ' 7 .; S910N NOI1Jf ' LSNO Oid- dWflc! 1";1VM �JN I"IOU� �I�SN�dNO W l3NVd 10211NOJ 21311IHO 70=_1016 nozl zx� ix (^b% b - 7J1/1)AoG HT1 - 11H0 NO1 00C S�Idl�a S011VW3H5S 10211-NO0 311118nS S9I D1.-14 -1 3W5 b T - 0 Gd -dwnd X1111 -I�. _I- 31111 8z -2 $0-1 Z -2 31tl0 10 1010 10 7010 31VO '1430 A9 03A0add1/ O3AO11d4V SI NOI1VDId103dS a01ONV N'JISSO SIHI A1111@H1d533V \ ra 0Zi (a 571, JD w) Ao$b' 2d -dWfld ZI3 LVM. aB111HO 2i31b9H 1 I 1 n 091' -- I iM1 e L_- 41; ® —I. S:W_, 9 SJI.J A021 2X IX ( a2,4 J i) A09f S dM VG LOU V /V1 7 IJ (- - ® 99086 'VM 'NOIN3H OZZL6 'HO 'GNVlll Od ❑ L£086 'VM IN3J1 ❑ 1OZ86 'VM '113I:13n3 ❑ Z0086 'VM 'NI:InenV )d- cllNfld I3_1_`c./M 213GNSCNOO H I-I •)100'1) GN2 NO •77 NI j. qyI /Id 1Nd A071 boz lH - 10 - N LL N OD . ?1B.127/ H - 6N ZI�MO L �JN 11O00 (1I Nn NOS d�0 -ln0 219 1t//i/M MOI� °) 21H M01- bN11000 ! 1V1S, d 1f/ 32I ns01 - 0N3 VV N NI z Wdx 1021iHoD I nozl 21010b d6 /Oz h .: :1-* Q.1-9 c;k_— 1N3 ® V,134 S3I11110Vd 9VNancas 4Ja'11IH7 �NV'd1 9) A08b d 3.7 /ts DEW 1t/ j "a1Xa l)ID • 7/Oz (z 17VINO) J21dnIXnd s1 4704 rut 31. 03ACIadd1/ - a - DW NI a 1o1gn'J �141V1S dHOt NI Wax 1N0 - 10YINm Z do 41.1 4-M01 1V H711M f - i 1. dM. 1 - t — 'y17 W>d- __(z d0 - d g) -- ' O1.1al N I J O 1011NU3 NVV 23M01 �JN! I -0"0 1 0 is V15 ' NIHSf1Q 10 - ?> 13 - 11IH - J (ST11Vd NI 6321f1 -L OON'HVI O 1D2`d fl #l z w oInb ^1�N .N I - 1 9 n'1d T�1 0117anas �f�'1 - 1IH7 - a 17V1da7�4i 2 # 1d311IHJ ' - b -77W _- Zl .1-V __ . n • 5/ ■ 0 -1V mama Et= — — M y - �Y 2 L 1• oI NIHSfQ 34141'45 asdvds M ® -1/ MIll1�\I11 M - 3 VdS M ill 2 S_ 2'ON 01 -109„ brMl - 00'1 'IN dal IA 2R - d2A IA 2A 2A N .171 1A 2A ^,2A (E'4o _ _-_14141 1S .Wncl - - 4Ja M- QT1'11H'_ - _ N 4!a'I IIHO a7 9c* 1 (A 3kr) - z O - 9L 2 :I - 3H/IJ# • CW PUMPS PI, P21' P3 STARTER CKTS IIJ • MCC4 /I13,IE 2D . OLI Zuo REVISION MGG -4- Ci- IILLF MCC LOCATE) ON - 2ND - PLR... MD STATE COfIROL DOMO NEM 4 EIMOIR INSTALL .SOOT _CHILLER )'849630 ) 2 12 PIJL PV15b IN MCC ON 2N17 FLOOP, EIh2 (z)'S"AL, 3' 350 M EA . To SU13.,TA. 6G/ FS C.omPENSER FLOW SENSOR, CHILLE4 WATER PUMP (P9) - Y4 cOND, COOLIN4 WATP.R PUMP (Flo) OO 2SHP 3 /4'C, 3 _ _MCC 4/q CONTROL POWER SUPPLY T20rAC G f�cr✓ovc Pulv,r P -S 7'74-7I2S -QO Mellen I k INSTALL FILO LEVEL R 4:MIIFS 7L No3 -66 LzIUC�JIJ( 1,� CT Pia nTr_ 4n0V DerywisF 7 T 7Si/,- t -1 C) OARC✓ I. ei 2 Ph ;• /z c, 2' { ( 3/2"c,5 14 ..HIL.L WATER PUKP (P3) _*4 3 6 -MCC 4/4B SONIP. CODLI1.161 , NATEP, PUMP(PYD; C- T 1� `- 1 D15L fCWUA)G TIJK I -L Or.ILY ) ELECTRODE FITTING MAKE UP VALVE c4 F MANE UP VALVE ON LOW LEVEL HEATER CUTOUT GRCOND CHILLER Ns 3 ADD POMP, P -7 L3_ CMCS PANELS I'C 2YaC -3 -36 MCC 4 A I /2G,4 # 14 I]I L V I iwl I 1 ., - ' /2G -2YEla 1:VAPOKATOR FLOW SENSOR CHILLED WATER f„ PUMP P2 ■ - 3 /4 3 M GG 4/ /4,5 e M LG 4/5D ADDE D. CHEM- FEED CONTROLLERS . I car, cr-v c,.Ir,T roc 4 CHILLF_R. N' Z • '/e c 1� _ CONO N-• SW �a EVAP FiATOR . FLOW_ SENSOR w I. o I /2 "C, 4' TO SOLENOID BLEED VALVES I'c- 3 # 4 MC'G 4 /SC. MC1�1�V 2Vat- 3 -3E0_M CM / Mc'C 3A C 27Z (3) 35DMCNI '2G -4414- { f2�C 3412 MC. 4 /IE ED COOLING ATER PUMP PS CND LI TRANSFORMER ucO Ers ".■ c:a INN WATER LEVEL .TROLLER SCHEMATIC ( A E CIE I l;J W 5 -8 A • R b kb P. 7 DATE SY C O REVISION 155UE_ eoz. REVIEW 4 PURCHASI145 ISSUE FOR CONSTRICTION APPROVED DATE 3.29.83 5 -C 8 -2 - 83 1 0.28 -88 2."c CC4 /2E-: Yac - 3 4 1 2 MCC4 /2B_ UP UNIT MOUNTE STARTER (6Y CHILLER MFR TYP. 72 "c EVAPOPNATOR FLOW SENSOR C CHILLER N21 I ' C- 3#4 MCC 47IC CONTROL _PANEL (T`(P) 2. 4# 14- 0IS CONNEGT(TY - P) CoV, 400A, N 2414 MAIN C IRCULATING POME P - 7 501-1P MAIN CIRCULATING PUMP P - 7A CHILLED.. WATER RUMP P V2C -3 #12' . ;_mGC 4/113 _COND. COOLING 1W AT ER PUMP P. GP,OL_!ND FLOOR.. PLAN CALE - 1 /4- " =■' BOE /A/0 FACILITIES DEPARTMENT ! I L - -- EVAPORATOR. FLOW SEAISOR r 20.4 CHEMICAL FEED CONTROLLERS..__ (6Y MECHANICAL) Y2 G- 2 *12.. TO PANEL: P -I AT MCC # 2O.SQ5_. CONTROL CKT DISC sw(wP) t0 YILEN2ID VALVE 4. ELECTRODE FITTI/JG NEMA 4 WA1ER LEVEL CONTROL BOX CONDENSER. PLOW SENSOR. D AUBURN, WA. 98002 D EVERETT, WA. ' 98201 ❑ KENT, WA. 98031. ❑ PORTLAND, OR. 91220 ❑ RENTON, WA. 98055 ■ ■ EE • 1131. '14 AG SECTION 1 A. D 40 I'C 36 r"FCC4 /6D 14 3KW HTR "12 SEGTIO . W A �• JMW GAOL- N ei ToWEP, NO- 3 9 POLE, E0A NO FUSE W .p # 6A Io NP 10 %z'C 3: 1/68 T -STAT 40H V I C,3 #6 M /J 4 E132 _TERMINAL BLOCK AT CHILLER CONTROL PANEL '/z K5C -(3) BELDEN 1 '%7 ,I To ROBERTSASLJ PIJL ON 2 FLR NEXT To MCC-3 INSTALL CKT. TU MGL Pop, COOLINCT TOWER. INSTALLA POLE NO FUSE. WP SW TO ENABLE LOCKOUT OF COMPLETE SECTION OF COOLING TOWER. INSTALL HEATER_ BL GK. . INSTALL NEW STARTER CUE3ICLE IN MCC -4 AND EXTEND CKT TO NON FUSIBLE. SAFETY SW CON NEST TO EQUIP. MCC4/4E 'Iz "c -(2) BELDENA 4,761 '(z"RSC (1) BELDEN ¢1:17S,1 AB T HIS DESIG AND /O ILITY R SPECIFICATION IS APPROVED APPROVED. BY DEPT. DATE _o CONTACTOR IJ I FH CONTROL XFMR 4 /6E DRAWN BY DATE GNAP,UHAS CHECKED 3 CHECKED APPROVED APPROVED MCC4 /c,D START /STOP PB (117 of 4) COOLING TOWER NTROL. N =2 I RLat Cc THERMOS 4 POLE 30 A NO FUSE WP I • 1 POLE 3 08 NO FUSE. I P CONTROL I INTERLOCK OCT: 1 . 4 4 POLE 308 NO FUSE 0 WP Y2'C, 2N14 "P 0 1 CONTROL CKT. 30 NP .'.. i /bE NOTES CON STPEUC floN NdTt 1 /2" C, 2#14 CONTROL CKT NC- N1112 EIS E132 TITLE 14 AT DI G. SW. WP 3KW HTR GOIJTAGTOP - I/2 -3'12, 2'14 Asa _lib - 518 552 NICC G 3 # 8 14 MCC 4 /1.0 / vo DAMPEN CONTRO 1 /2."C.-z.14 I /2 "C -2 3 /4'C- 3.E I� RUN UNDER ROOF 3112 TO PNL P -I I GKTS 19. 21 NEM4 4 OJATEI LEVEL COM 1ROL PAX I W IT-I FLEX TO YTLE1.I0ID VALVE a- ELELTRODE FI rfI sJA PARTIAL ROOF PLAN SCALE 1 /4 " = I - O'i 1 _FURNISH AND INSTALL_ ICON TACTO12 ROOF H ATC H CQOLI NG . -'CELLO ER- N' 1. — THERMOSTAT OA NEM REFERENCE_ DP1AWINQS _ 109 -102- 2.001-5151' CONTROL SCHEMATICS 109 - 102 - 2O02 CHILLED, MOTOR CONTROL 109. - 102 - 2002-E 50 4150VI DISTRIBUTION NOTES I 4 ENCLOSURE.___ Tnov6 CCI5i rECT pL.I,J.D(� TDwL-1� 4 2EPC/}ee LAJLT1-1 1 6o hp VI b AASc Dux, IDI lOE 20.2, E /3S 3MD Us L L T I NSTE C Hs-0-. . *oLp r N4T 8KL'- F(c'TYTMC 1 NIL) ort.zok■Au >c, He.Thir T8AUE o2P•Lc , - , NIT 15 7KV./ I N S'1 THE AUSTIN COMPANY O<61ONRRS • INOINERRR • 7UILORRi SUBTITLE CHiLLEfR POWER PLAN 19 BUILDING '9 -102 - THE BOEING COMPANY '[�rElcl nrnnACkrrAII n�wETCa CC ATTI WA DISC. SW. WP. 20 8 4 3KW HTR s EE _NOTE 1 �2C- 3 #I2,2SIA. - DAMPER CONTROL SWP _%2•C -2 *14 Y2 C 24 A 20 AMP, 3 POLE, 48OV CENTER EXPIRED AN C $Q2 Mo1_165 CATY Pca2 555Iltif•'IS'tL52.cp sPei✓. RECEIVED aTr o= TuNwILA PERMIT CENTER THIS DW61, WAS AUSTIN N0. 101 - 105- ZOOZ - B21 LAST REVISION SHEET JOB NO: ISO. NO, SYMBOL T DATE n EVi Sion PUMP N° CT-I P -2 P4 I D IE 2A - 26- CH -2 P - 9 P -10 P -7 P -Co 5C 5D BY SY M A 7SSUE FOR S0 % REV 1E -'' ANC7. P C °vEC PURCHASE. - . Pc an E ISSUE_FOR PURCNASWL-G f ADiJ C,O Fi FaTR1'c -r O!� NOT I AT•1b PROVIDE 3 - BOO MCM LUGS PER PHASE FOR INCOMING SERVICE / 3 O NAMEPLATE_ DATA INCOMING LINE CHILLED WATER PUMP MAIN CIRCULATING PUMP COOLING TOW ER No. 1 CHILLED WATER PUMP INCOMING LINE COND. COOLING WATER PUMP COOLING TOWER N2 a GHIt -LED WA„ PUMP COND. COOLING CI- BILLER N WATER PUMP SPAP1= SPARE 5 pAP,E SPAPPE _CHILLER S12 2 CHILLED WATER .PUMP = . CON D: CJOLINC WATER PUMP PAN HEATER COOLING TOWER N° I _PAN HEAT ER COOLING TOWER N PAN _SPARE HEATCP GC OLINGU TOWEri N ° - 3 VACUUM PUMP VACUUM _RUMP MAIN CIRCULATING PUMP GUND GOOL WATER PUMP SP.P,E 406A -14441 ToWEP— 6, G GGOLI PUe - row ti 74,1,1 C - 699+4d- 6rT6WER i=�t.i APPROVED EmTE G, C . 12/9/82 3 -29 -S3 SYM F" G K MCC -4 GHIL_LER MOTOR CONTROL. CE.NTE.P_ MOTOR CI-AT. 6KR, HP 7 %2 5o 30 7 %2 I0 30 ZO 10 210 210 20 25 3KW 3 KW' 8Y 25 25 VOLTS 45,0 480 480 480 480 480 480 480 480 480 480 480 4 480 4 480 480 3 0 T kAM' � POLE FRAME RI P 3 50 -150 3 275 -lox 3 215 -IOOc S 50 -150 100.300 3 275 3 GO 3 100-3DO 3 . 350 100 -300 3 3 50 -150 50 -150 100-30C 3 350 3 GO 3 GO 3 Po 5. 2O 3 20 350 3 TO — SEE NOTE #C:. 3 3 3 3 3 3 SO 3 3 3 3 3 3 3 3 3 3 3 MCP MCP MCP MCP MCP MCP MCP MCP L5 MCP MCP MCP MCP LI3 MCP MCP FB F5 FB LS PS 3 Zo 3 P5 SIZE 3 3 3 3 2 2 MOTOR ST A RT E R COIL 120V I2OV I2OV 1205 I2OV I2OV 120V 120 120V 12.0V 120V 120V 120V 1201/ 1ND, ALIX. CONTACT LIGHT N.O. N.C. RED RED RED RED RED RED RED RED RED RED RED RED RED 6E0 H -O -A CONTROL 1-1-0 -A . IN COVER IN COVER L-1 -0 -A IN COVER 1-4-0 -A IN COVER N-o-A. IN COVER H -0-A IN COVER H O A 114 COVER I-1-0 -A IN COVER REMOTE 5 -0 -A I N COVER N -0 -A IN COVER H -O -A IN COVER H - O -4 IN COVER H - O - IN COVED ot 3 3 3 3 MOP 1VN MCP IZOV P8P I — I7 REb RED I PIED I — t — P,EI7 1 H -U -A IN COVER H -04- 11.1 COVER }-I -o -A IN coVEP, 55 ADJ. OVERLOAD RELAY SETTING AT Moron FLA 55 35 35 27 27 50 00 MOTOR CIRCUIT PROTECTOR SETTIIJC-, 320 320 430 400 H -o -A I N GOJEF H 0 A IN C.OV f�� - -' —I eD-- A-tt 14 H-a- l t�COiER I 50 4 025 �r ❑. AUBURN, WA. 98002 THE ii ®E7iV COMPANY ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 FACILITIES DEPARTMENT ❑ PORTLAND, OR. 91220 CRPACITOE SIW E PDVVE6 FRLTDE_ LOSE IS 1<056 7.5 17508 7,5KVNL 7.510E14 ISt1UAZ 7,5 KVA C 13K5Ak 13 05556 5. (c. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY kkOTES 1. MCC SHALL SE GRACED FOR. 42,000 .AMPS. SYM. 2. MCC WIRING SHALL__ NEMA CLASS I TYPE'. S. COMBINATION STARTERS __SHALL_ iE DRAW -OUT _T- Y_P_E. 4- EACH STARTER- SHALL E._.FURNI 4ED WITH ITS OWN CONTROL TRANSFORMER. 480/12_0 V WITH FUSED A.LSID GROUNDED - _SECOI 1DARY_ __ 1___._ -_ ALL- slAMEPLATES _ SHALL - ESE_ gL -f C4K AND E 1 ENOLIC__ WITH .SCRIBED WH1TE PROVIDE A -8° x 3" 6LACFc AND WI-I TE PHENOLIC MAIN NAMEPLATE WITH I V4" SCRIBED WHITE CHAIRACTETRS To READ- _" G1 -LILLF e MGG ". 7_ MAIN AND VEP.TICAL * CONTINUOUS - AMPERE RATING OF „ MCP' FRAME CIRCUIT 13REAI -REP- (MOTOR CI RCUIT PROTECTOR -) TYPE WITH ADJUSTAP,LE INSTANTANEOUS TRIP DRIP SETTINGS PER MANUFACTURES TAE,L -E AND $ECOMMENDATIONS C ONSTRUCTION NOTCS EEMOVE EX1511NCT CooLtr -a `tOLJSS- 'K3 3 stoO W P.% 847r`T .. p..zmov". co:) Power 654206 04P4C-tne$ Lst E Rocrc7r 01055 e 6D& DtaPo6in Om OP ol.o , 5•l S) :NSTpL MELD CoOUNfr TDVJE71C 4 vr'K�tOL.E TVCpIoL IHVEI rc2 Du ...I ANb V D RPLPT LI/ -IlT0 ��Lf3Lu' FQ.t;Q.uEj.t� pR.tve. P -EYLft� ' EKtSITIvCr MC Sk�h'Keil" AN CN WITH MC' 5D.4 (.65, 000/114) CD char F 2N2 -. SO-o3 Fov hassey F.Qc caN. Pc r-rs, lusTALL C0 0bul7 S W 1" DEPT DATE CHARACTERS. BUSSES SHALL FOE COPPER.. CKT 3D o RSoa °vE LAQI -" coo-HG- Tow ca- "3 CT 3 R.e_ I30L`* SPR,2_5 DRAWN BY A E SUBTITLE c Ec EDH�AJS 5 89 L1 L_LER MOT - CONTROL. CENTEI e s4 /s3 MGC-'4 CHECKED TITL APPROVED BUILDING 9 °10.2 .,-■ ■,- nnnutn AIADAAIV. Loc - FUTEO /4/Sove tnaTaK. EXPIRED M01 -165 AP R 1 82002 Me LAST REVISION SYMBOL SHEET JOB N0. i;W TOILA oc I s 1 1 1 7,'73 RECEED CI N TY OF NKWIL: FERSATCSroisp . is DATE INCOMING LINE A INCOMING LINE A 350 A CIRCUIT _BLtEAKER A 3SO A CIRCUIT BREAKER A 350 A CIRCUIT BREAKER 6PP-P+E _ A SIZE HP cHw -Wry PurA? P P ` SIZE I 71--1P 5 SIZE I 10 HP 5 • SIZE 1 -IVY SPAQ -E SIZE 5 5O HP C .SIZE 3 30 I-1P C SIZE I SP/'H A 13 SIZE 2 20HP 5 ToA TO _ I I 6L 15R SIZFl� — - DscoJNECT oil- Felt VFO 6o Hr 1 c.....Ntr - mum_ C. SIZE I SIZE Z SPARE 25 HP C C SIZE 3 50 HP C SIZE 3 50 I-I P D SIZE 3 2 0 N P D StEt=t I _La"t {P" SPAke b SIZE_ I 4 20A 20A I� U 4DR SPA.LP,E D.4DL SIZE 3 25 HP ■ D SIZE 3 - P — 1 E SIZE I __7) HP E SIZE I 10 HP E SIZE l 20A SF'AP a E E 'O" L 20" 20" I_ 20" I_ 20" ►4 20 4 T .N 10 -UII n EVi Sion PUMP N° CT-I P -2 P4 I D IE 2A - 26- CH -2 P - 9 P -10 P -7 P -Co 5C 5D BY SY M A 7SSUE FOR S0 % REV 1E -'' ANC7. P C °vEC PURCHASE. - . Pc an E ISSUE_FOR PURCNASWL-G f ADiJ C,O Fi FaTR1'c -r O!� NOT I AT•1b PROVIDE 3 - BOO MCM LUGS PER PHASE FOR INCOMING SERVICE / 3 O NAMEPLATE_ DATA INCOMING LINE CHILLED WATER PUMP MAIN CIRCULATING PUMP COOLING TOW ER No. 1 CHILLED WATER PUMP INCOMING LINE COND. COOLING WATER PUMP COOLING TOWER N2 a GHIt -LED WA„ PUMP COND. COOLING CI- BILLER N WATER PUMP SPAP1= SPARE 5 pAP,E SPAPPE _CHILLER S12 2 CHILLED WATER .PUMP = . CON D: CJOLINC WATER PUMP PAN HEATER COOLING TOWER N° I _PAN HEAT ER COOLING TOWER N PAN _SPARE HEATCP GC OLINGU TOWEri N ° - 3 VACUUM PUMP VACUUM _RUMP MAIN CIRCULATING PUMP GUND GOOL WATER PUMP SP.P,E 406A -14441 ToWEP— 6, G GGOLI PUe - row ti 74,1,1 C - 699+4d- 6rT6WER i=�t.i APPROVED EmTE G, C . 12/9/82 3 -29 -S3 SYM F" G K MCC -4 GHIL_LER MOTOR CONTROL. CE.NTE.P_ MOTOR CI-AT. 6KR, HP 7 %2 5o 30 7 %2 I0 30 ZO 10 210 210 20 25 3KW 3 KW' 8Y 25 25 VOLTS 45,0 480 480 480 480 480 480 480 480 480 480 480 4 480 4 480 480 3 0 T kAM' � POLE FRAME RI P 3 50 -150 3 275 -lox 3 215 -IOOc S 50 -150 100.300 3 275 3 GO 3 100-3DO 3 . 350 100 -300 3 3 50 -150 50 -150 100-30C 3 350 3 GO 3 GO 3 Po 5. 2O 3 20 350 3 TO — SEE NOTE #C:. 3 3 3 3 3 3 SO 3 3 3 3 3 3 3 3 3 3 3 MCP MCP MCP MCP MCP MCP MCP MCP L5 MCP MCP MCP MCP LI3 MCP MCP FB F5 FB LS PS 3 Zo 3 P5 SIZE 3 3 3 3 2 2 MOTOR ST A RT E R COIL 120V I2OV I2OV 1205 I2OV I2OV 120V 120 120V 12.0V 120V 120V 120V 1201/ 1ND, ALIX. CONTACT LIGHT N.O. N.C. RED RED RED RED RED RED RED RED RED RED RED RED RED 6E0 H -O -A CONTROL 1-1-0 -A . IN COVER IN COVER L-1 -0 -A IN COVER 1-4-0 -A IN COVER N-o-A. IN COVER H -0-A IN COVER H O A 114 COVER I-1-0 -A IN COVER REMOTE 5 -0 -A I N COVER N -0 -A IN COVER H -O -A IN COVER H - O -4 IN COVER H - O - IN COVED ot 3 3 3 3 MOP 1VN MCP IZOV P8P I — I7 REb RED I PIED I — t — P,EI7 1 H -U -A IN COVER H -04- 11.1 COVER }-I -o -A IN coVEP, 55 ADJ. OVERLOAD RELAY SETTING AT Moron FLA 55 35 35 27 27 50 00 MOTOR CIRCUIT PROTECTOR SETTIIJC-, 320 320 430 400 H -o -A I N GOJEF H 0 A IN C.OV f�� - -' —I eD-- A-tt 14 H-a- l t�COiER I 50 4 025 �r ❑. AUBURN, WA. 98002 THE ii ®E7iV COMPANY ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 FACILITIES DEPARTMENT ❑ PORTLAND, OR. 91220 CRPACITOE SIW E PDVVE6 FRLTDE_ LOSE IS 1<056 7.5 17508 7,5KVNL 7.510E14 ISt1UAZ 7,5 KVA C 13K5Ak 13 05556 5. (c. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY kkOTES 1. MCC SHALL SE GRACED FOR. 42,000 .AMPS. SYM. 2. MCC WIRING SHALL__ NEMA CLASS I TYPE'. S. COMBINATION STARTERS __SHALL_ iE DRAW -OUT _T- Y_P_E. 4- EACH STARTER- SHALL E._.FURNI 4ED WITH ITS OWN CONTROL TRANSFORMER. 480/12_0 V WITH FUSED A.LSID GROUNDED - _SECOI 1DARY_ __ 1___._ -_ ALL- slAMEPLATES _ SHALL - ESE_ gL -f C4K AND E 1 ENOLIC__ WITH .SCRIBED WH1TE PROVIDE A -8° x 3" 6LACFc AND WI-I TE PHENOLIC MAIN NAMEPLATE WITH I V4" SCRIBED WHITE CHAIRACTETRS To READ- _" G1 -LILLF e MGG ". 7_ MAIN AND VEP.TICAL * CONTINUOUS - AMPERE RATING OF „ MCP' FRAME CIRCUIT 13REAI -REP- (MOTOR CI RCUIT PROTECTOR -) TYPE WITH ADJUSTAP,LE INSTANTANEOUS TRIP DRIP SETTINGS PER MANUFACTURES TAE,L -E AND $ECOMMENDATIONS C ONSTRUCTION NOTCS EEMOVE EX1511NCT CooLtr -a `tOLJSS- 'K3 3 stoO W P.% 847r`T .. p..zmov". co:) Power 654206 04P4C-tne$ Lst E Rocrc7r 01055 e 6D& DtaPo6in Om OP ol.o , 5•l S) :NSTpL MELD CoOUNfr TDVJE71C 4 vr'K�tOL.E TVCpIoL IHVEI rc2 Du ...I ANb V D RPLPT LI/ -IlT0 ��Lf3Lu' FQ.t;Q.uEj.t� pR.tve. P -EYLft� ' EKtSITIvCr MC Sk�h'Keil" AN CN WITH MC' 5D.4 (.65, 000/114) CD char F 2N2 -. SO-o3 Fov hassey F.Qc caN. Pc r-rs, lusTALL C0 0bul7 S W 1" DEPT DATE CHARACTERS. BUSSES SHALL FOE COPPER.. CKT 3D o RSoa °vE LAQI -" coo-HG- Tow ca- "3 CT 3 R.e_ I30L`* SPR,2_5 DRAWN BY A E SUBTITLE c Ec EDH�AJS 5 89 L1 L_LER MOT - CONTROL. CENTEI e s4 /s3 MGC-'4 CHECKED TITL APPROVED BUILDING 9 °10.2 .,-■ ■,- nnnutn AIADAAIV. Loc - FUTEO /4/Sove tnaTaK. EXPIRED M01 -165 AP R 1 82002 Me LAST REVISION SYMBOL SHEET JOB N0. i;W TOILA oc I s 1 1 1 7,'73 RECEED CI N TY OF NKWIL: FERSATCSroisp . is DATE REVISION REPLACE COOLING TOWER #3 J #703542 -00 Install next to MCC # Breaker In MCC. 150 AMPS 1 emt 90 amp 60 MP, Inverter duty motor Orlveuency #2 XHHW, wire aFRS - R90 O O -® • I Cuttler- Nnnner n O ' • pSV9050nP- SMOA00 6...s'. ® O I L -- —J #2 XHHW, wire L GE BTH3363R j To CMCS. 3/4 =� On Of analog input (4 -20mA) analog output (4 -20mA) Install on roof S ervice Disconnect Ise pFRS -1215 24x24x8 Hoffman enclosure Outdoor rated BY R. Aisaka SCALE: no scale APPROVED DATE SAA J. Vavrek 9/5/01 C11 2 S TAT RaDF HEAT TRACE TAPE, 3 watts per ft. Install on roof • • • • • See BAC -9095 B drawing for manufacturer's instructions. .500 KVA transformer GE #9T51B0008 L Cooling, Tower #3 REVISION BY • Old Coolinig Tower #3 New Cooling Tower #3 7 KW Pan Heater APPROVED DATE 15 amp MCC4 /4E 90 amp MCC4 /6C QLAsrOElNG. S -4" v 7KW pan heater CHECKED 9 -10" 60 HP INVERTER DUTY MOTOR PARTIAL ROOF PLAN SCALE: 1/4"- 1'-0" ROOF HATCH v CONSTRUCTION NOTES Remove the existing Cooling Tower #3. Replace with new cooling tower #3. Hookup 60 hp inverter duty motor, VFD, 7KW pan- heater, T —stat, water level system, Heat trace tape. connection to CMCS. See drawings and manufacturer's instructions in 20.05 he installation Relabel all compartments of the MCC with proper identification. Call Roger Aisaka 655 -5303, if more information is required. e•S...r r1e•r4 n inn rr - nn GENERAL NOTES: 1.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL BARE TO BE #12 THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/4800 "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. 6.) 7.) DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. EXPIRED APR 1 82002 CIN CFE UKNi_c PERMIT CPO E, ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN R. AISAKA CHECKED - ENGINEER DATE SUBTITLE PARTIAL PLANS, SECTION, AND TITLE DIAGRAM CURRENT REVISION SHEET E502 SYMBOL DATE 9-04-0 SYM - I REDRAWN FROM 109- 102 - 1001 -S7 A ( REPLACE COOLING IOWLA NO.3 60 512 51601 S10 S160 S10 DIESEL MUFFLER SEE DWG N0. c , 109 - 102 -1004 SHEET S -1 5160 S4 RP -1 •• i RP -1 S160 S11 51601 S11 RG -2 51601 S12 S160 511 5160 011 I S160 S12 o_ RP -1 RP -1 RP -1 X RP -1 RP -1 / RP -1 19' -9" 4 s1 6Si1 S160 S12 7 02 I RG -1 5160 511 RP -1 RP- RP -1 SLOPE 1 /4 " /FT RG- RG -1 RG -1 RP -6 RG -1 RP -1 RP -1 RG -1 I C2 REVISION YA I 4'- I 15 -9" t 5' -5" ��� BY KB / MA 300 KB.MA 19' -9" G -2 5160 510 G - 2 APPROVED DATE 8.8.01 8.31.01 SYM SLOPE 1 /4 " /FT 14' -4" i Si6 51601512 79' -0" G -2 G -2 -4 21.8 . 219 REVISION RG -2 BY G -2 G -2 19' -9" ROOF FRAMING PLAN SCALE: 1/8 " =1' -0" APPROVED DATE Bb 1' -4 3/8" _I I GIRT LINE fI {20.65 21.3 20.4 6 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE C RAWN CH CKE ENGINEER NECKED DATE UBTITLE ITLE ROOF FRAMING PLAN 1 1 111 I11A1/'' ll LEGEND 1VI01 -165 GENERAL NOTES 1. FOR STRUCTURAL STEEL SCHEDULE, SEE DWG 9 -102 -S260. CONSTRUCTION NOTES EXPIRED CURRENT REVISION APR 1 8 ZOO? SHEET S160 As SYMBOL CITY OF TUKWII? RERM, CENTER DATE 8.31.01 STRUCTURAL STEEL SCHEDULE MARK MARK USED AS REMARKS C -1 Wi2x79 - COLUMN C -2 W12x53 COLUMN FB -1 W18x55 FLOOR BEAM FB -2 C10x15.3 FLOOR BEAM FB -3 C8x11.5 FLOOR BEAM FB -4 W18x60 FLOOR GIRDER FB -5 W18x97 FLOOR GIRDER FB -6 W18x55 FLOOR GIRDER G -1 C10x15.3 GIRT T 1 {- � G -2 W12x14 + C10x15.3 GIRT G -3 C10x15.3 OPENING FRAME G-4 (2) C10x15.3 +(1) L6x6x1/2 OPENING FRAME RG -1 W16x40 ROOF GIRDER RG -2 W27x94 ROOF GIRDER RG -3 W18x97 ROOF GIRDER RP -1 C10x15.3 OPENING FRAME A ROOF BRACE RP -2 W14x30 ROOF PURLIN RP -3 W14x34 ROOF PURLIN RP -4 W14x38 ROOF PURLIN RP -5 W14x48 ROOF PURLIN RP -6 W12x16 ROOF BRACING S -1 W14x30 STRUT A -1 (2) L4x3x1/4 VERTICAL WALL BRACING. A -2 (2) L6x4x3 /8 VERTICAL 2ND FLR. BRACING A -3 (2) L4x3x1/4 HORIZONTAL ROOF BRACING ,i A -5 • "- • .. SHEET S -14 L4x3x3 /8 HORIZONTAL ROOF BRACING SY REM O REDRAWN FROM 109 - 102 - 1001 -S7 REPLACE COOLING TOWER NO.3 JOB 70354200 BY KB /MA KB /MA APPROVED DATE 8 10.01 8.31.01 SYM REVISION BY APPROVED DATE A&0E7Jv ® SUBTITLE MO1-165 EXPIRED APR 1 8 2082 cZ % w rT+�e RECENEi- CIryOFTI!: ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CHECKED ENGINEER CHECKED DATE TITLE STEEL SCHEDULE Ili 111 111A1!'' A AA*" CURRENT REVISION SHEET S260 SYMBOL DATE A 8.31.01 SY A W12x16 W12x16 1 DETAIL SCALE: 1/4"= l' -0" 1 1/2" ROOF DECK SECTION SCALE: 1"= l' —0" REVISIO REDRAWN FROM 109 -102- 1001 - S7 REPLACE COOLING TOWER NO.3 5502 2" MA. INSULATION 3/8 "x3 1/2" FLAT BAR SECTION SCALE: 1 1/2 " =1' -0" 4x4 COL. COOLING TOWER NO.1 OR NO.2 (WT =11 K.) TYP S160 S502 - 2 "x1 /2" STIFFENER EACH SIDE W12x16 (4) 3/4 "0 H.S.B. FROM BAR 4x1/2x0-4 EA. SIDE TS 4x4 PITCH POCKET S502 BY KB /MA JOB#70354200 KB /MA f1/4 f 1/4 IH 3 "0 STD STEEL PIPE BEAM W12x16 S502 APPROVED DATE 8.8.01 8.31.01 W12x26 EXIST W12x16' EXIST W12x16 C-6 1/2" 7' -4 5/8" DETAIL SCALE: 1 " =1' -0" SECTION SCALE: 1 1/2"=1'-0" 12 EXIST 2" 3 INSULATION & 1 1/2" ROOF DECK 3 "0 STD FIPE TYP, 4 PLACES COOLING TOWER NO.3 (WT= 16,540 LBS) f , 1 516015502 Ml 2x16 5502 3/16 1/4" STIFF. R ,TYP BOTH SIDE. PROVIDE AT ALL BEAM CROSSINGS AND BELOW COOLING TOWER CONNECTION REVISION L3x3 1/2x5/16 EA SIDE. W /(2) 3/4 "0 M.B. A5 (L4x3x3/8, LLV) SECTION SCALE: 1 1/2 " =1' -0" BY (2)3/4 "0 A325 -SC BOLTS TYP TO RG -1 TOP •& BOT. FLANGES APPROVED S502 DATE 1/4 DETAIL SCALE: 1 1/2 " =1' -0" NEW W12x26 7/8 "0 MOUNTING BOLTS, TOTAL 8 (4)3/4 "0 A325- SC BOLT EXUDING WI2x16 L4x3x3/8, LLV 3/8 ". STIFF. IC TYI> 1/4 / EXIST 4 "11/2" STIFF IC EA SIDE; EXIST W12x16 BEAM PERPENDICULAR TO FRAMING NOT SHOWN FOR CLARITY - 3 "0 STD PIPE BRACE I. © A C SECTION SCALE: 1"= 1' —0" S502 RP3, EXISTING Z ) LA7417E7A1/0 EXISTING 4x3/8 GUSSET ft AND (3)7/8 "0 A325 BOLTS CP -RG -1, EXISTING .1/8 "x14 7/8" FLAT BAR 516015502 NOTE: FRAMINI BELOW NOT SHOWN FOR CLARITY. DETAIL SCALE: 1 1 /2"=1' -0" 1/4" STIFF BOTH SIDES 3/8 "x4 1/2" FLAT BAR L4x3x3/8, LLV 3/8x4 1/2" FLAT BAR, SEE DETAILS 5W6 ON THIS DWG W12x26 STIFF. IC ( " A325 -SC BOLTS IXIST Ml 2126, CUT OUT EXTRA LENGTH AT THE TWO ENDS 1/4 2 MIN 1/4 2 MIN EXIST 05414 W/ 411/211' -0" TOP FE & 41411/2 STIFF EA SIDE 5502 3/8" STIFF. IP. , SEE SECTION C/5502 6 S502 TYP 3/4" 2 3/4" DETAIL SCALE: 1 1/2 " =1' -0" APPROVED 012126 1/4" STIFF. R TYPICAL BOTH SIDES 1/4 TYP TYP 5502 `02 TYP EXIST W12x26 EXIST 4x1/2 STIFF. R EACH SIDE SECTION SCALE: 1"=1'-0" VVV 3/8" STIFF. fe SEE SECTION C/5502 1/4 3/16 DETAIL SCALE: 1 1/2"-1' 0 3' -0" C.P., \TYP EXISTING 1313x3/8 "x0 -5 1/2 EACH SIDE 3/16 EXISTING L4x4x 1 /2x0 -5 W/41411/2 STIFF. It ® C TYP EXISTING 00414 NEW 3 "0 STD PPE BRACING PERPENDICULAR TO FRAMING NOT SHOWN FOR CLARITY 5502 3/8"x4 1/2" FLAT BAR 1/4" STIFF. PL. W12x26 S502 EXISTING W12x16 Mo LEGEND GENERAL NOTES CONSTRUCTION NOTES E> VERIFY EXISTING TS4x4x3 /8 BASE CONNECTION TO THE ROOF BEAM FOR MIN. 1/4" FILLET WELD ALL AROUND. D. NOTIFY PUGET SOUND MAINTENANCE TO PROVIDE PITCH POCKET AND TO WATER TIGHT THE ROOF PENETRATION. 65 EXPIRED APR 1 8 0002 CITY UKK TO IK ILA. OCT 18 _.j!1 AS N,: ,;t:0 Jzl RECIVED CITY E OF TUKWIIJ PERMIT CENTER ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DATE CHECKED NUIN CHECKED SUBTITLE TITLE SECTIONS AND DETAILS UILDING 9 102 CURRENT REVISION SYMBOL A SHEET S502 JO B NO DATE 8.31.01 COMP N0.