HomeMy WebLinkAboutPermit M01-193 - US COURTSCity of Tukwila (206) 431 -3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
MECHANICAL PEPMIT
Permit No: M01 -193
Type: B -MECH
Category: NRES
Address: 14240 INTERURBAN AV S
Location:
Parcel #: 336590 -1881
Contractor License No: MERITMI163CM
_,tatus. ISSUED
Issued: 10/17/2001
Er.pires: 04/15/2002
TENANT US COURTS Phone:
14240 INTERURBAN AV S, TUKWILA, WA 98168
.OWNER FAIRWAY CENTER ASSOCIATES
C/0 HALLISSEY RJ CO INC, 12835 BEL -RED RD, #140, BELLEVUE WA 980
CONTACT DOUG FROHARDT Phone: 425 602 -3242
9630 153 AV NE, REDMOND WA 98052
CONTRACTOR MERIT MECHANICAL INC. Phone: 206 883 -9224
9630 153RD AVENUE N.E., REDMOND, WA 98052
* * * * * * * k * * * * * k * * * * * * * * * * * * * * k * * * * * * * k k * k k k * * * * * * * * * * * * * * * * k * * * k * * * * * * * k * k k
Permit Description:
MOVE.3 SUPPLY DIFFUSERS; MOVE 2 RETURNS; ADD 1
CROSSOVER RETURN
UMC Edition: 1997 Valuation:
Total Permit Fee:
200.00
46.50
****•**'******************************** k*** k * * * *k ** * * ** * ** * * * * * * * * * * * * * **k*
/b -l? -D/
Periir:ii CeNt'er Authorized Signature Date
I. hereby `'certify that I have read and examined this permit and know the
salW`to be, true and correct. All provisions of law and ordinances
governing this work will be complied with whether specified herein or not
The granting of this permit does not presume to give authority to violate
or can'ce,1 the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign for and
obtain this building permit.
Signature: Date: /CI /7 /
Print Name: OL?_ rrokq.tcI Title: T -AI
This permit shall be.cume,null and void if the work is not commenced within
180 days from the date o.f issuance, or if the work is suspended or
abandoned for a period of 180 days from the last inspection.
ACTIVITY NUMBER: M01 -193 DATE: 10 -15 -01
PROJECT NAME: U.S. COURTS EXPANSION
SITE ADDRESS: 14240 INTERURBAN AVENUE SOUTH
XX Original Plan Submittal Response to Incomplete Letter #
Response to`Correction Letter # Revision # After Permit Is Issued
DEPARTMENTS:
Build Division
10 '140-191
Public Works n
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
c
Fire Prevention ?re
6 (o7(ob�
Structural
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-1 6-01
Complete
\PRROUTE.DOC
5/99
APPROVALS OR CORRECTIONS: (ten days)
Approved n Approved with Conditions
REVIEWER'S INITIALS:
CORRECTION DETERMINATION:
Approved n Approved with Conditions
REVIEWER'S INITIALS:
Incomplete ri Not Applicable
TUES /THURS ROU NG:
Please Route Structural Review Required n No further Review Required
REVIEWER'S INITIALS:
DUE DATE 11 -13 -01
Not Approved (attach comments)
;It
11
Comments:
DATE:
DATE:
DUE DATE
Not Approved (attach comments) ri
DATE:
ACTIVITY NUMBER: M01 -193 DATE: 10 -15 -01
PROJECT NAME: U.S. COURTS EXPANSION
SITE ADDRESS: 14240 INTERURBAN AVENUE SOUTH
X ,Original Plan Submittal
Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Is Issued
DEPARTMENTS:
Building Division
Public Works
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-1 6-01
Complete Incomplete n Not Applicable
Comments:
TUES /THURS ROUTING:
Please Route
PLAN REVIEW /ROUTING SLIP
n
REVIEWER'S INITIALS:
Structural
Struct ral, Review Required
APPROVALS OR CORRECTIONS: (ten days)
Fire Prevention
Approved Approved with Conditions' Not Approved (attac co ' ments)
REVIEWER'S INITIALS: DATE: 'a 1 6 0
CORRECTION DETERMINATION:
Approved n Approved with Conditions
\PRROUTE.DOC
5/99
n
DATE:
Planning Division n
Permit Coordinator n
No further Review Required
DUE DATE 11 -13 -01
Not Approved (attach comments)
REVIEWER'S INITIALS: DATE:
DUE DATE
k -f.i iHveak,, `i v"P•,.Ntdektlire4 s ;�itirztm'2
PERMITNO,: MO1 `� 93 ..�
MECHANICAL PERMIT APPLICATIONS
INSPECTIONS
00002 Pre- construction
00050 WSEC Residential
00060 WA Ventilation /Indoor AQC
00610 Chimney Installation /All Types
00700 Framing
01080 Woodstove
01090 Smoke Detector Shut Off
01100 Rough -in Mechanical
01101 Mechanical Equipment/Controls
O 01102 Mechanical Pip /Duct Insul
• 01105 Underground Mech Rough -in
O 01 115 Motor Inspection
0/ 1400 Fire Final
1800 Final Mechanical
04015 Special -Smoke Control System
CONDITIONS
0001 No changes to plans unless approved by Bldg
Div
• 0014 Readily accessible access to roof mounted
equipment
• 0016 Exposed insulation backing material
0019 All construction to be done in conformance
w /approved plans
O 0002 Plumbing permits shall be obtained through King
Co
0027 Validity of Permit
0003 Electrical permits obtained through L & I
O 0036 Manufacturers installation instructions required
on site
O "BTU maximum allowed per 1997 WA State Energy Code"
O 0041 Ventilation is required for all new rooms &
spaces
0005 All permits, insp records & approved plans
available
O "Fuel burning appliances
O "Appliances, which generate...."
O "Water heater shall be anchored...."
Additional Conditions:
TENANT NAME: V 5,,_... C 4- 5ifecosiao
FEES
Basic Fee (Y/N)
Supplemental Fee (Y/N)
Plan Check Fee (Y/N)
Furnace /Burner
to 100,000 BTU (qty)
Over 100,000 BTU (qty)
Floor Furnace (qty)
Suspended /Wall /Floor- mounted Heater (qty)
Appliance Vent (qty)
Heating/Refrig/Cooling Unit/System (qty)
Boiler /Compressor
to 3 HP /100,000 BTU (qty)
to 15 HP /500,000 BTU (qty)
to 30 HP /1,000,000 BTU (qty)
to 50 HP/1,750,000 BTU (qty)
over 50 HP /1,750,000 BTU (qty)
Air Handling Unit
to 10,000 cfm (qty)
over 10,000 din (qty)
Evaporative Cooler (qty)
Ventilation Fan (qty)
Ventilation System (qty)
Hood (qty)
Incinerator — Domestic (qty)
Incinerator — Comm /Ind (qty)
Other Mechanical Equipment (qty)
Other Mechanical Fee (enter $$)
Add'I Fees — Work w/o Permit (Y/N)
Insp Outside Normal Hours (hrs)
Reinspections (hrs)
Miscellaneous Inspections (hrs)
Add'I Plan Review (hrs)
Plan Reviewe
Permit Tech:
Date:
Date:
TUES /THURS ROUTING:
Please Route
Approved
CORRECTION DETERMINATION:
Approved I I
\PRROUTE.DOC
5/99
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M01 - 193 DATE: 10 -15 -01
PROJECT NAME: -U.S. COURTS EXPANSION
SITE ADDRESS: 14240 INTERURBAN AVENUE SOUTH
XX Original Plan Submittal Response to Incomplete Letter #
Response to Correction. Letter # Revision # After Permit Is Issued
DEPARTMENTS:
Building Division n Fire Prevention le
Public Works Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete n Incomplete n
Structural Review Required
REVIEWER'S INITIALS: G
APPROVALS OR CORRECTIONS: (ten days)
REVIEWER'S INITIALS:
Approved with Conditions
REVIEWER'S INITIALS:
Planning Division
Permit Coordinator
DUE DATE: 10-16-01
Not Applicable \ IA .
Comments:
No further Review Required n
/0--fi, DATE:
DUE DATE 11 -13 -01
Approved with Conditions n Not Approved (attach comments)
n
DATE:
DUE DATE
Not Approved (attach comments) n
DATE:
Project Name/jena •
,C�P44A,5)0/ I..1.5. C,ouI' - 1 - S
_
„ . I f • 1 , 1 .. f 1 4
i�,l�� �.. � 4�,...Y
�a,� r,.
c sfr t, I ti � ;:",
1 � ,�J, 1 ,
t�r�r.. ,. '..
Value of Mechanical Equipment:
Site Address : , 1
19 '2- Z� e O r ct A) AA So .
City State/Zip:
;�,&. -;l4
Tax Parcel Number:
3T3 'O- M(( -0 Van ATO- cool-r
Prope y O wn e ' C---°
,O I1 4 / /)
_ 0
Print name: rn to
Phone: ( ►fig ) 4/55-12q 2
Str je� : &/ r- Re _I Rd /
DI •
0
/
)� evti
C_ ity State2ip:
(.v2 gSooS
Fax #: ( )
Contractor: e ; Cr / W t )C � /
N l
Address: 9 ��d
r S
Phone: (y25) g b'3 • qZZ
Street Addre s r d
q 3v X 53 Ate, N
n _ _ City State/Zip
f0N , 12& '1905 L
Fax #: (IiZ5 ) g95-909•2_
ContactPerson: J / .
l _ vl /
-
Phone: (L/25) (,p2 -3V z
Street Address: MGr 1 ' /144c A. ) Gtr )
City State/Zip:
Fax #: ( )
, T i l
;�BU1L` DING „OWNER�'OR.AUTHORIZED.A'GENT � -� •`
. .. �. . ,1, �I . � .... w
..1 , 1. , t
,.. .�.
„ . I f • 1 , 1 .. f 1 4
i�,l�� �.. � 4�,...Y
�a,� r,.
c sfr t, I ti � ;:",
1 � ,�J, 1 ,
t�r�r.. ,. '..
Signature:
Date: / 1
_ 0
Print name: rn to
1/
Iu
i l
S
Phone: (��
_
Fax Fax #: (
)
Address: 9 ��d
r S
`
'� p
city/state/zip:
f1 n fi tt ,.. a ( i ) A-
Mechanical Permit Application
ai,MECHANICAL', AND "APPROVAL REQUESTED: (TO BEF /LLED,' "OUT`B1�' APPLICANT), :'il:'.i'"t �,',.,i'
Description of work to be done (please be specific):
4\0, t- 2-efv t iA s
crossov-fr Rofinet
Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of
application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor
Registration ".
Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the
State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the
permit will be required as part of this submittal.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
11/2/99
meth pern s,doc
)cal 2 3
CITY OF TI WILA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
Project Number:
Permit Number.
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written
request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be
extended more than once.
Date application accepted:
Date application expires:
4 415.110 A
Application taken by: (initials)
�i�
✓
Submittal Requirements
Floor plan and system layout
Roof plan required to identify individual equipment and the location of each installation (Uniform
Mechanical Code 504 (e))
Details and elevations (for roof mounted equipment) and proposed screening
Heat Loss Calculations or Washington State Energy Code Form #H -7
H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut-
off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical
Code 1009).
Specifications must be provided to show that replacement equipment complies with the efficiency ratings
and other applicable requirements of the Washington State Nonresidential Energy Code.
Structural engineer's analysis is required for new and the replacement of existing roof equipment
weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be
stamped by a Washington State licensed Structural Engineer.
Mechanical Permits
COMMERCIAL: Two complete sets of drawings and attachments required with application submittal
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced.
RESIDENTIAL : Two complete sets of attachments required with application submittal
Submittal Requirements
New Single Family Residence
Heat loss calculations or Form H -6.
Equipment specifications.
Narrative with specification of equipment and chimney type.
If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe
condition.
11/2/99
miscpml.do•
Change -out or replacement of existing mechanical equipment
I Narrative of work to be done, including modification to duct work.
Installation of Gas Fireplace
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water.
heaters or vents being installed or replaced.
•
et 11
y T t .,1
Y t.
'
:d 1/41. '' t3' •.n
r •
CITY OF TUKWILA
Address: 14240 INTERURBAN AV S
Suite:
Tenant: US COURTS
Type: B-MECH
, Parcel W: 336590-1881
•.erpit Conditions:
Electrical permits shall be obtained through the Washington
State Division of Labor and and all electrical
''work will be inspectWbYtthat:agentkj248-6630).
2. ;No changes will.be, made to the plans unless approved by the
r 1
-Engineer and * the'jukwila Building Division.
3. All permitsi;,in'ipection,Ocords, and approved plans shall be
available.,:at-thejob site prior tO the start of anY_con-
struction.: Thesedocumentsare to be Maintained and avail-
,
able urft0 final inspection approval is granted.
,
'.. All cdnStructidn'to,be done in'conformance with approved
plan*,,aild requirements of the Uniform Building Code (1997
Edie10 amended, ,Uniform Mechanical Code (1997,Edition),
,
andfWashiqgton Energy Code (1997 Edition)
...,. .
5. Validity of PermitThe issuance of a permit or approval of
plans, specifications, and computations shall not he con-%;
0:45uedNtp perikit for, or an approval of, any violation,
dtoany of the provi-sions of the 'building code or of any
other ordinance of the Jurisdiction. No permit presuming to
give •uthority to ,violate or cancel the provisions of this
code shall be'valid.
Manufacturers installation ,instructions required on site ,
for the 'building 'Inspectors review.
I here that I have read these condition s and will comply
. -
with them as,,out,lined. All provisions of law and ordinances governing
this work willbe complied with, whether specified herein or not'.
•
Permit. No: M01-193
Status:
Applied:
Issued:
ISSUED
10/15/2001
10/17/2001
The granejng of this permit does not presume to give authority to
-
-
violate or'cancei' the provisions of any other work or local laws
. ,
regulatingponstri!ption or the performance of 'Work.'
ignature:
Date':
Pr'int Name:
. • . . ;$' ...........................
TITN
TRAUSMIT'Aamb
T4lyment:%Mth
iriu it:
Site uJcIre
t
0.00)
00.0)322. 100
r t • ■
7
V•
; .1t 4 1 .4 10 4 4.:4i 4, • •' :231 ' • f "
. .
, .% • • •
tiisk4c4.**44*4.*4 **.A*4
A. WA TRANSMIT
44.k4* *4•4**,44 Aic4),*4*11/4***4 *If 4 3kir*****47ir ktic/ri
er; R0101347 Amount: 46.50 10/17/01 1052
fad: CHECK Nutiltion: MERIT MECHAN3CAL In it. KAS
Not M01-193 Type: B-MECH MECHANICAL PE1Ml7
No: 336590-1861
ts: 1,4246 INIERURBAN AV S
fotal Foes: 4t).50
46.50 Tuf0 ALL. Pmts..: 46.50
Balance: .00
AA4 iti14411.**4 4)%A*4714A*4444***44****4441k#444444 IN.+44i44%
.Description
PLAN CHECK NONRES
MECHANICAL -- tODWRES _
01 la 10/19 9710 TOTAL 46050
• • • 7.• • . • . • .. • • . . • • „ .
, • ,,, • • .
Amount
9.30
37.20
' ‘... • - • ,,, - • .• • ' ' ••■.' • )■'•••• :a:- • •-‘,"3•4-4 t,••••• • ; ;•-r• 0-•
P9'ect: t _
c 1)01 -t-
6.0
.e of Irppectio
Ktt)C
r, n: Ft wt.
I /
dress
IL1, 1 --10 Snm+rkrin ichl -.
c ed: i
10 - 2-7/ 0 1
Special instructions:
Date w ted: /
3
1 ( : 1". .
Rei cu.te .ter,:,
V.,..t.
A A-4 4o t
Phm • 10 — I& ig
s
7-1 INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 98188
Approved per applicable codes.
COMMENTS:
Ocivo P I p-r
— / r‘i
GA/.5 2-
PERMIT NO.
(206)431-3670
Corrections required prior to approval.
- PP
mi.g7 Date:
specto :
• , 7
.00 REINSPECTION EE REQUIRED. P ior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100.. Call to schedule reinspection.
Receipt No:
Date:
■••,
e•••
, — • • ..■• :••
. .-. r ey.::'':r. w ± ,
Typg R4a
Date called:
-I - • 0 01'
-,,,,,,,, . ..., _......;,.
,-; • ::- , tf AI
0 —
4
Special instructions:
'':.•_.' ."..
; .='i'
<31
Date wanted: jo723
1
( P.m.
Requester: .,
0q*.e
Phone:
. • ,
• •
• " I .
• : „., „
• "
t •
INSPECTION RECORD
Retain a copy with permit
INSPECTION. NO.
CITY OF TUICWILA BUILDING DIVISION
000 Southcenter Blvd, #100, Tukwila, WA 98188
MMENTS: ,
`Ornivi.W )2619fre7 ..-z_i e70/
%
, .
i'S /1 f el --/— 6"
)
:Od PAA€
fr;fr 5 .. - oz...)e 1 tf-7 1, /2000 _ coec- etis
-i 9-. )/A 1 /1/ A /
Xpproveci per applicable codes. Corrections required prior to approval.
PERMIT NO.
(200
& P /1/ S
D A3 ate:
.99 REINSPECTION E REQUIRED. Pri to inspection, fee mZt be paid
it6300 SmithCenter Blvd., Suite 100. Cali o schedule reinspection.
ReCe1Pt
Date:
' • • '," - ■ -; - '
F625.052.000 (8191)
PARtMENTOFLABOWANDIt4DUSTRIES
. „
• . • .
REGISTERED AS PROVIDED .BY LAW.AS
/ CONT GENERAL
• .
..40: • .3. • •
• " • n ••• • ,
..;■• - • • • )
" r
MERIT MECHANICAL
P0130X - •
REDMOND WA 98073-2109 -
mePir MI I C JY
Notary Public in and for the State of
Washington residing in Redmond.
67/
I certify that this is a true and correct copy of an original license.
M01- 113
Balance Due: $
Need Current Contractor Registration Card:
Need to Enter. Contractor Information in Sierra:
Yes [) No
Yes ❑ No
rk��GQnta
krats
L GENERAL
A. VERIFY AND CONFIRM ALL DIMENSIONS AND EXISTING CONDITIONS.
NOTIFY OWNERS REPRESENTATIVE FERRARI DESIGN GROUP (FDG) OF ANY
DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN OR
PROGRESS OF WORK. PRIOR TO PROCEEDING WITH THE ITEM OF WORK
AFFECTED.
B. COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. LAWS AND
ORDINANCES GOVERN IN CASE OF CONFLICT BETWEEN METHODS OR
STANDARDS OF INSTALLATION OR MATERIAL QUALITY. NOTIFY (FDG) OF
ALL CONFLICTS. ALL WORK SHALL CONFORM WITH THE PM UBC AS
AMENDED AND ADOPTED BY THE CITY OF TUKWILA.
C. OBTAIN SEPARATE PERMITS FOR ALL ADDITIONS AND /OR
MODIFICATIONS TO:
I. MECHANICAL
2. ELECTRICAL
3. FIRE SPRINKLERS
4. FIRE ALARMS/PROTECTION
IN ACCORDANCE WITH AND AS REQUIRED BY ALL CODES AND
REGULATIONS.
D. COMPLY WITH REQUIREMENTS IN THESE SPECIFICATIONS FOR
STANDARD OF WORKMANSHIP, PERFORMANCE, AND QUALITY.
I. WHERE MATERIALS, FINISHES OR EQUIPMENT 15 NOT SPECIFICALLY
IDENTIFIED, THE CONTRACTOR WILL BE REQUIRED TO SUBMIT SAMPLES OR
INFORMATION DETERMINING QUALITY AND PERFORMANCE TO
OWNER/TENANT PRIOR TO ANY WORK.'.
E. COORDINATE SUPPLIERS AND SUBCONTRACTORS FOR PROPER
SEQUENCE OF OPERATIONS, PREVENT DUPLICATION OF EFFORT; PROVIDE
ORDERLY PROGRESS OF WORK;
F. MAINTAIN STRUCTURAL INTEGRITY OF BUILDING E +,/ELL. ANY SUPPORT
OF NEW EQUIPMENT BY SHELL STRUCTURE SHALL BE REVIEWED AND
APPROVED BY A WASHINGTON STATE LICENSED STRUCTURAL ENGINEER.
CALCULATIONS AND DETAILS SHALL BE PROVIDED FOR PERMIT
SUBMITTAL PURPOSES.
6. GLEAN UP.
I. DAILY SIT- CLEANUP: ALL RUBBISH MUST BE REMOVED AT THE END OF
EACH WEEKDAY AND, WHERE THE SPACE 15 CURRENTLY OCCUPIED,
VACUUMED IN THE IMMEDIATE WORK AREA.
2. FINAL CLEANUP: SCOPE OF CONTRACTOR'S WORK TO BE A COMPLETE
TURNKEY CLEANUP OF THE ENTIRE TENANT SPACE INCLUDING, BUT NOT
LIMITED TO, ALL FLOOR COVERINGS, INTERIOR WALLS AND GLAZING,
INSIDE SURFACE OF EXTERIOR GLAZING, AND DOORS. CLEANUP IS NOT
LIMITED TO THE IMMEDIATE WORK AREA.
DUMPSTERS: CONTRACTOR TO PROTECT ASPHALT SURFACES WITH
WOOD BLOCKING OR SKIDS TO PREVENT DAMAGE TO THE PAVED
SURFACES.
2. SITE WORK. NONE REQUIRED
5. CONCRETE, NONE REQUIRED
4, MASONRY, NONE REQUIRED
S. METALS
A. FRAMING. "GRABBER' OR EQUIVALENT, AS DETAILED ON DRAWINGS,
WITH FIRE BLOCKING AS REQUIRED BY GODS. BOTTOM PLATE
CONNECTION AT 24" O.G., INTO EXISTING WOOD DECK.
B. FURRING: "GRABBER OR EQUIVALENT, AS DETAILED ON DRAWINGS.
FUR OUT RAIN LEADERS, CONCRETE PILASTERS AND COLUMNS AND SHIM
CONNECTOR PLATES, ETC. A5 REQUIRES TO COVER.
G PROVIDE GALVANIC. INSULATION BETWEEN DISSIMILAR METALS WHERE
IN CONTACT.
6. CARPENTRY
A. GENERAL: PROVIDE BLOCKING AS REQUIRED FOR FIXTURES,
ACCESSORIES, GRAB BARS, ETC.
B. CABINETRY, NONE REQUIRED
C. DRAFTSTOPS: EXIST516 -NO NEW WORK
7. THERMAL AND MOISTURE PROTECTION
A. INWLATION: EXISTING NO NEW WORK REQUIRED
B. ROOFING:
I. FLASH AND COUNTERFLASH ANY AND ALL PENETRATIONS OF ROOFING.
ROOF PAT,f4ING MUST BE ASPHALT BASE MATERIAL COMPATIBLE WITH
EXISTING ROOFING.
2. PLACE ROOF MOUNTED EQUIPMENT ON CURBS WITH SLOPES AS
REQUIRED FOR PROPER DRAINAGE. GANT SIDES OF CURBS, APPLY
ROOFING MATERIAL AND MOP OVER. GAP CURB TOP AND CAULK OVER
ALL NAILS AS REQUIRED TO ENSURE WEATHERPROOFING.
3. VERIFY CONDITIONS OF BUILDING SHELLPROOF WARRANTY. ALL WORK
SHALL BE PERFORMED IN ACCORDANCE WITH TERMS OF THE WARRANTY
TO INSURE THAT CURRENT WARRANTY REMAINS IN FORGE.
6. DOORS, WINDOWS, HARDWARE
A. DOORS: 3' -0" BY T' -O ", I -3/4" THICK SOLID GORE, UNLESS NOTED
OTHERWISE MATCH EXISTING BUILDING STANDARD
I. AL EXIT SHALL BE OPENABLE FROM THE INSIDE WITHOUT USE
OF KE. OR ANY SPECIAL KNOWLEDGE OR EFFORT. MATCH EXISTING
BUILDING STANDARD.
2. FURNISH RATED ASSEMBLIES WHERE NOTED ON DRAINING A2 FLOOR
PLAN.
B. FRAMES: MATCH EXISTING BUILDING STANDARD.
C. HARDWARE: MATCH EXISTING BUILCING STANDARD
I. ALL HARDWARE- BY SCHLAGE LOCK COMPANY. OR EQUA, AS
APPROVED. 6Y OWNER AND TENANT AS TO FINISH, LOCK FUNCTION, ETC.
MATCH EXISTING BUILDING STANDARD.
2. ALL HARDWARE USED IN ACCESSIBLE BUILDINGS AND FACILITIES
SHALL CONFORM TO THE REQUIREMENTS' PER "WASHINGTON STATE RULES
AND REGULATIONS FOR BARRIER FREE DESIGN (WAG- 3I -30) CHAPTER II.
3. VERIFY KEYING REQUIREMENTS. SPECIALTY ITEMS AND QUANTITIES
REQUIRED FOR COMPLETE INSTALLATION PRIOR TO ANY WORK.
TENANT IMPROVEMENTS FOR:
US COURTS EXPANSION
FAIRWAY CENTER BUILDING 'B'
14240 INTERURBAN AVENUE SOUTH, TUKWILA, WASHINGTON 98168
CITY OF TUKWILA
GENERAL NOTES
D. GLAZING
I. PROJECT GLAZING SUBJECT TO FEDERAL GLAZING STANDARDS AND
GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO
THE REQUIREMENTS OF CHAPTER 24 UGC.
2. ANY MODIFICATION OR ADDITION TO STOREFRONT FRAMING AND
GLAZING SHALL MATCH EXISTING STOREFRONT SYSTEM.
9. PINISFEB
A. FLOORING (REFER TO PLAN ON DRAWING A21
I. CONTRACTOR WILL BE REQUIRED TO FIELD VERIFY EXISTING
SLAB/SUBLOOR CONDITIONS. ANY SLAB/SUBPLOOR PREPARATION
REQUIRED PRIOR TO INSTALLATION OF FINISH FLOOR MATERIAL 15 WITHIN
THE SCOPE OF WORK.
2. CARPETING: MATCH EXISTING CARPETING IN AREAS WHERE NEW
CARPETING IS INSTALLED.
3. VINYL COMPOSITION TILE: NONE REQUIRED
4. SHEET VINYL: NONE REQUIRED
5. BASE: 4" ROPPE VINYL: BASE IN COLOR COORDINATED WITH FLOORING.
SEE PLAN ON DRAWING A2 FOR ADDITIONAL' INFORMATION.
B. GYPSUM WALLBOARD:
I. 5/8" GYPSUM BOARD, TAPED AND READY FOR PAINT.:.
2. ATTACH TO FRAMING/FURRING WITH I GAB. SCREWS AT 8" D.G. AT
PANEL EDGES AND 12" O.C. AT INTERIOR SUPPORTS.
B. 5/6" TYPE 'X' GYP BOARD AT ALL RATED ASSEMBLIES IDENTIFIED ON
DRAWINGS.
C. PAINT: KELLY MOORE OR APPROVED EQUAL.
I. GENERAL WALLS: ONE GOAT LATEX PRIMER AND TWO GOATS•INTERIOR
LATEX EGGSHELL ENAMEL.
2. DOORS AND FRAMES, STAIN AND VARNISH ALL WOOD DOORS AND
FRAMES TO MATCH EXISTING BUILDING STANDARD.
SUSPENDED CEILINGS. (EXISTING TO BE REPAIRED AND TILES
REPLACED AS NECESSARY)
I. LAY -IN ACOUSTICAL BOARD: ARMSTRONG "MINABOARD ": 2'X4'X5/8"
FISSURED PATTERN. VERIFY/MATCH WITH EXISTING BUILDING STANDARD.
2. SUSPENDED SYSTEM: 2'X4' HEAVY -DUTY COMMERCIAL 11/2" MAIN AND
INTERMEDIATE TEES. NO. 12 GAUGE HANGERS AT 4 ON CENTER EACH
WAY PER USG STANDARD, CAPABLE OF SUPPORTING 160 POUNDS. ATTACH
HANGERS TO STRUCTURAL FRAMING MEMBERS WITH 1/4" SCREWS
PENETRATING 11/4" INTO STRUCTURE. MATCH EXISTING EUILDIN6
STANDARD.
3. SUPPORT LIGHT FIXTURES WITH TWO NO. 12 CAUSE HANGERS FROM
FIXTURE TO STRUCTURE ABOVE. LIGHT FIXTURES WEIGHING MORE THAN 56
POUNDS SUPPORTED BY 4 HANGERS, ONE IN EACH CORNER.
4. CEILINGS HORIZONTAL TO A TOLERANCE OF I /6" IN 10'-0" MEASURED
EACH WAY. GRID TO REMAIN A CONTINUOUS PATTERN THROUGHOUT.
5. SEISMIC BRACING AS AS REQUIRED BY MC. 15 EXISTING TO REMAIN.
10. SPECIALTIES
A. FIRE EXTINGUISHERS. (EXISTING) PROVIDED. PER CODE. 1 PER 5000
5F. OF FLOOR AREA, WITHIN A MAXIMUM T5' TRAVEL DISTANCE FROM ANY
POINT.
II. EQUIPMENT NONE REQUIRED
12. FURNISHINGS, NONE REQUIRED
15. SPECIAL CONSTRUCTION. NONE REQUIRED
14. CONVEYING SYSTEMS. NONE REQUIRED
15. MECHANICAL (BY SEPARATE PERMIT)
A. PLUMBING: NONE REQUIRED
B. 6A5 PIPING, NONE REQUIRED
G. HEATING, VENTING AND AIR CONDITIONING: ROOF TOP UNITS - GAS
HEATING ELECTRIC AIR CONDITIONING. MODIFICATION OF EXISTING SYSTEM
AND INSTALLATION OF NEW EQUIPMENT AS NECESSARY TO BE DONE UNDER
SEPARATE MECHANICAL PERMIT.
i6. ELECTRICAL. (BY SEPARATE PERMIT)
EXISTING. OUTLETS, SWITCHES, SERVICE, TO REMAIN -
ADDITIONS/MODIFICATIONS UNDER SEPARATE PERMIT AS DIRECTED BY
TENANT /OWNER AND AS NOTED ON PLAN.
A. POWER PANEL: VERIFY LOCATION, SIZE AND CONFIGURATION OF
EXISTING SERVICE
B. OUTLETS AND WIRING INSTALL NEW OUTLETS AS DIRECTED BY TENANT
IN ACCORDANCE WITH ALL APPLICABLE CODES.
VERIFY DEDICATED CIRCUIT LOCATIONS WITH TENANT. ALL CONDUCTORS
SMALLER IN SIZE THAN A 46 SHALL BE COPPER TERMINATE ALUMINUM
CONDUCTORS WITH GABLE TERMINATORS/DURESS ALARM SYSTEM.
G. TELEPHONES: INSTALL NEW PULL WIRES IN WALLS TO NEW LOCATIONS
AS DIRECTED BY TENANT AND AS NOTED ON PLAN. ALL WIRING AND
INSTALLATION OF TELEPHONE AND ALARM SYSTEM IS N.I.G. (BY TENANT)
D. COMPUTER DATA LINE: TO BE COORDINATED AND INSTALLED BY
TENANT UNDER SEPARATE CONTRACT.
E. POWER POLES: NONE REQUIRED.
F. LIGHTING: EXISTING TO REMAIN OR BE RELOCATED PER PLANS.
I. GENERAL. 2'X4' 3 -TUBE LAY -IN ENERGY EFFICIENT FLUORESCENT
FIXTURES. WITH ELECTRONIC BALLASTS. REFER TO REFLECTED CEILING
PLAN.
2. LAMPS: F32T8/SP41 OR APPROVED EQUAL.
WASHINGTON STATE NREG INFORMATION - 1 EDITION
ALL WORK OF THIS PERMIT 15 BEING PERFORMED WITHIN AN EXISTING,
FULLY HEATED, INSULATED BUILDING. NO MODIFICATION 15 PROPOSED TO
BUILDING ENVELOPE.
OkEER,
TENANT.
PROJECT CONTACTS
RJ. HALL155EY COMPANY
12835 BEL -RED ROAD. SUITE 4 ,40
BELLEVUE. WASHINGTON 96005
PHONE. (425) 455 -9292
FAX: (425) 455 -2016
CONTACT, LEE SHEPHARD
U5 COURTS
14240 INTERURBAN AVENUE SOUTH
TUKWILA, WASHINGTON 96168
PRO.I.T A.DDI., 14240 INTERURBAN AVENUE SOUTH, TUKWILA, WA 96168
TAX PARGEL NOa •536590- 1811-06 /00280- OOOI -00
TENANT AREA, APPROX. Sp30 S.F.
TOTAL ENDO. AREA. APPROX. 51;122 S.F. (BUILDING 'B')
AONSTRUGTIONI TYPE. TYPE VN SPRINKLERED
SITE ION.. MI
OGGI,PA AY, B, OFFICE
Al
A2
WORK UNDER THIS PERMIT
WORK OF THIS PERMIT WILL BE LIMITED TO THE DEMOLITION OF 16 LIN.
FT. OF EXIST.. OFFICE PARTITION CONSTRUCTION OF 1100 LIN. FT. OF
NEW OFFICE PARTITION AND INSTALLATION OF FOUR NEW 3'-0"X7' -0"
DOORS AND THREE FULL HEIGHT SIDE LIGHTS AT NEW DOORS.
SHEET INDEX
COVER SHEET
FLOOR PLANS AND DETAILS.
ARCHITECT,
FERRARI DESIGN CROUP
1227 154TH COURT NE, SUITE 203
REDMOND, WASHINGTON 96052
PHONE: (425) 621 - 3383
FAX: (425) 821 -3213
EMAIL. NerrarldcelynoearthllnKnet
CONTACT. FRANK HEFFERNAN, AIA
GENERAL CONTRACTOR,
PROJECT DATA
MMI SERVICES INC.
245 EAST ONSET WAY
ISSAQUAH, WASHINGTON 96027
PHONE, (425) 369 -8655
FAX. (425) 369 -6656
LICENSE NO: MMISCIA094P5
CONTACT, BRYAN MOORMAN
D(iq3
VICINITY MAP
SCALE, NO SCALE
Date
Permit No
VICINITY MAP
SCALE, NO SCALE
LEGAL DESCRIPTION
LO - 1.1 - ,13L'DCRTFFEttlL t Rj T SEATTLE CARD N TRACTS.
understand that the Plan Check approvals are
subject A errors and omissions and approval of
plans does not authorize the violation of any
adopted code or ordinance. Receipt of con-
tractor's copy of approved plans acknowledged
-7 7.3 Stint. BE MADE TO
3Tio WY101 A NEw ltlyuFFE9,u
SEPARATE PERMIT
REQUIRED FOR:
❑ MECHANICAL
g ELECTRICAL
IS� LUMBING
'GAS PIPING
CITY OF TUKWILA
BUILDING DIVISION
RECENED
amoPTUNwlu
PERMIT CENTER
ARCHITECT:
PROJECT:
00Z'` : t 3
FERRARI
D ESIGN
G ROUP
ARCHITECTS, PS
12277 134TH COURT NE
SUITE 3203
REDMOND, WASHINGTON
98052 -2433
(OFFlCEI 625821 3383
(FAX) 625.821.3213
(EMAIL) feneriE04ip.�enM14nk net
US COURTS
EXPANSION
Fairway Center Bldg. 'B'
14240 Interurban Ave. South
Tukwila, Washington 98168
SHEET INFORMATION:
PLANS;
DETAILS
OWNER:
R.J. HALLISSEY
COMPANY
12835 Bel -Red Road
Suite #140
Bellevue, Washington 98004
TENANT:
US COURTS
14240 Interurban Ave. South
Seattle, Washington 98168
REVISIONS:
ott c:
aVnm»s\
.R015,
GA NA. F.HEFFERNAN
Mum By. H. YAMANUTO
RNA AUGUST 31.2001
Sheol No.:
PERMIT DRAWINGS
Al
LEGEND
EXISTING WALL TO REMAIN.
EXIST.N6 WALL TO BE REMOVED.
NEW WALL PARTITION PER DETAIL 1 /A2.
BUILDING GRIDLINE.
CEILING GRID.
EXISTING 2x4 (3) TUBE RECESSED
FLUORESCENT LIGHT FIXTURE TO REMAIN.
EXISTING 2X4 (3) TUBE RECESSED
FLUORESCENT LIGHT FIXTURE TO BE
REMOVED/RELOCATED.
LOI EXISTING 2X4 (3) TUBE RECESSED
FLUORESCENT LIGHT FIXTURE NEW LOCATION.
DETAIL DESIGNATION.
<>—\ ® EXIT SIGN.
KEYNOTE DESIGNATION.
LIGHT SWITCH (E' NEXT TO SYMBOL
DESIGNATES EXISTING TO REMAIN)
TELEPHONE/DATA OUTLET (E'NEXT TO
SYMBOL DESIGNATES EXISTING TO REMAIN)
OUADPLEX OUTLET ('E' NEXT TO SYMBOL
DESIGNATES EXISTING TO REMAIN)
DUPLEX OUTLET ('E' NEXT TO SYMBOL
DESIGNATES EXISTING TO REMAIN)
DURESS ALARM OUTLET W/R)LL STRING
KEYNOTES k
I. EXISTING 3' -0 "X7' -0" SOLID GORE DOOR AND FRAME TO
REMAIN.
2. NEW 3' -0,1 -0' SOLID GORE DOOR AND FRAME TO MATCH
15UILDIN6 STANDARD.
S. EXISTING 5'-0"X1' -0" SOLID LORE DOOR AND FRAME TO
MATCH BUILDING STANDARD. 20 MIN. RATED ASSEMBLY FOR
ONE HOUR CORRIDOR. HARDWARE TO MATCH EXISTING ENTRY
DOOR AND PER TENANT DIRECTION.
4. NEW 2'-0'X1' -0" TEMPERED GLASS RECITE TO MATCH
BUILDING STANDARD.
5. EXISTING 2'- 0'XT-0" TEMPERED GLASS RECITE TO REMAIN.
6. EXISTING CARPET TO REMAIN. REPAIR/PATCH WHERE
NECESSARY. (OR NEW CARPETING PER TERMS OF LEASE
AGREEMENT)
T. INFILL OF WALL OF ONE HOUR CORRIDOR SHALL CONFORM TO
UBC TABLE TB, ITEM I6 -I.1 5/8" TYPE 'X' GYP 6D. EACH SIDE OF
0.018 (25 6A) STUDS 6 2' -0" O.G.
20 6A. 5 5/8" METAL SND BRAGIN6 TO
STRUCTURE AT 8' -0" O.G. 1.1/(2) 6 8 SHEET
METAL SCREWS AT EACH END. BRACING
TO BE PROVIDED WHERE DISTANCE
ETWEEN PERPENDIO'JLAR INTERSECTING
WALLS OR HORIZONTAL BRACING BETNEEN
WALLS EXCEEDS 8' -0' O.G.
EXISTING FIBERGLASS BATT TYPE
INSULATION HAS BEEN INSTALLED AT
UNDERSIDE OF ROOF STRUCTURE UNDER
PREVIOUS PERMITS.
— SUSPENDED ACOUSTICAL CEILING BOARD.
ATTACH TOP TRACK TO MAIN RUNNER OR
GROSS TEE • POINT OF INTERSECTION W/(I)
TYPE "S" SCREW.
5/8" 6W5 EACH SIDE ATTACH WT'PE
SCREWS a 8" PANEL EDGES 4 12' FIELD.
1/2 "x25 6A METAL SND a 24 0.C.
ATTACH 20 GA BOTTOM TRACK 6 24" . INTO
.
EXISTING WOOD DECK AT SECOND FLOOR
TYP. OFFICE WALL PARTITION
SCALE: I I /2' • I' 0"
0-
US CCUIRTS1, ADJACENT TENANT
LEASE SPACE LEASE SPACE
60+-0"
DEMOLITION FLOOR PLAN
SCALE: I /8' • I' -O"
WALL /MULLION DETAI L
O
OFFICE
Li
L
WORK RM.
OFFICE
OFFICE
CONFERENCE RM.
30'-0"
OFFICE
SUPPLY
RECORDS
OPEN OFFICE AREA
RECEPT
OFFICE
BUILDING COMMON CORRIDOR
OPEN OFFICEO 4
19'-4" VERIFY 14' -8 VERIFY
60T-0'
<5'
SECOND FLOOR PLAN
SCALE: I, • NO"
OFFICE
AR
WAITING G
I . 1 6
E >
hew Iocotevr5
SECOND FLR. REFLECTED CLG. PLAN
SCALE, I/D • I -0
US COURTS ADJACENT TENANT
LEASE SPAC LEASE SPACE
ADJACENT TENANT
ADJACENT TENANT
ONYX ENVIRONMENTAL
LEASE AREA
EUILDINS CO'rIMON CORRIDOR
1
FERRARI
DESIGN
GROUP
ARCHITECTS, PS
12277 136TH COURT NE
SURE e203
REDMOND, WASHINGTON
88062 -2433
IDFFICE) 426.821.3333
1FAXI426B21.3213
(EMAIL) fenmkeci8�lerthlink.nn
ARCNITECT:
PROJECT:
US COURTS
EXPANSION
Fairway Center Bldg. S'
14240 Interurban Ave. South
Tukwila, Washington 98168
SHEET INFORMATION:
PLANS;
DETAILS
OWNER
R.J. HALLISSEY
COMPANY
12835 Bel -Red Road
Suite #140
Bellevue, Washington 98004
TENANT
US COURTS
14240 Interurban Ave. South
Seat0e, Washington 98168
,re oc wxos Na >K
FCC) v
INrn
'newel O[Pte E0 vs. OD CD
we[x0IeoY
IN E0 MR ION n
.,anw
memo/ my Fm
a <xmto.
US ADJACENT TENANT
LE — ASE SPAGE' 9PAGE
CITY OF7UKWILA
y oe "li iwo PERMRCENTER
a Ch Fsdey. F.VEFFERNMI
8 16 2��t 68 8y itynk MOro
O N to' Deb: AUGUST 31.401
t N 5)G1d o
C tr
® LL
Sheet NO.:
PERWTORAWINOS
2
A2
3oDNo: 9404021