Loading...
HomeMy WebLinkAboutPermit M01-193 - US COURTSCity of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PEPMIT Permit No: M01 -193 Type: B -MECH Category: NRES Address: 14240 INTERURBAN AV S Location: Parcel #: 336590 -1881 Contractor License No: MERITMI163CM _,tatus. ISSUED Issued: 10/17/2001 Er.pires: 04/15/2002 TENANT US COURTS Phone: 14240 INTERURBAN AV S, TUKWILA, WA 98168 .OWNER FAIRWAY CENTER ASSOCIATES C/0 HALLISSEY RJ CO INC, 12835 BEL -RED RD, #140, BELLEVUE WA 980 CONTACT DOUG FROHARDT Phone: 425 602 -3242 9630 153 AV NE, REDMOND WA 98052 CONTRACTOR MERIT MECHANICAL INC. Phone: 206 883 -9224 9630 153RD AVENUE N.E., REDMOND, WA 98052 * * * * * * * k * * * * * k * * * * * * * * * * * * * * k * * * * * * * k k * k k k * * * * * * * * * * * * * * * * k * * * k * * * * * * * k * k k Permit Description: MOVE.3 SUPPLY DIFFUSERS; MOVE 2 RETURNS; ADD 1 CROSSOVER RETURN UMC Edition: 1997 Valuation: Total Permit Fee: 200.00 46.50 ****•**'******************************** k*** k * * * *k ** * * ** * ** * * * * * * * * * * * * * **k* /b -l? -D/ Periir:ii CeNt'er Authorized Signature Date I. hereby `'certify that I have read and examined this permit and know the salW`to be, true and correct. All provisions of law and ordinances governing this work will be complied with whether specified herein or not The granting of this permit does not presume to give authority to violate or can'ce,1 the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Signature: Date: /CI /7 / Print Name: OL?_ rrokq.tcI Title: T -AI This permit shall be.cume,null and void if the work is not commenced within 180 days from the date o.f issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. ACTIVITY NUMBER: M01 -193 DATE: 10 -15 -01 PROJECT NAME: U.S. COURTS EXPANSION SITE ADDRESS: 14240 INTERURBAN AVENUE SOUTH XX Original Plan Submittal Response to Incomplete Letter # Response to`Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Build Division 10 '140-191 Public Works n PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP c Fire Prevention ?re 6 (o7(ob� Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-1 6-01 Complete \PRROUTE.DOC 5/99 APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved n Approved with Conditions REVIEWER'S INITIALS: Incomplete ri Not Applicable TUES /THURS ROU NG: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DUE DATE 11 -13 -01 Not Approved (attach comments) ;It 11 Comments: DATE: DATE: DUE DATE Not Approved (attach comments) ri DATE: ACTIVITY NUMBER: M01 -193 DATE: 10 -15 -01 PROJECT NAME: U.S. COURTS EXPANSION SITE ADDRESS: 14240 INTERURBAN AVENUE SOUTH X ,Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-1 6-01 Complete Incomplete n Not Applicable Comments: TUES /THURS ROUTING: Please Route PLAN REVIEW /ROUTING SLIP n REVIEWER'S INITIALS: Structural Struct ral, Review Required APPROVALS OR CORRECTIONS: (ten days) Fire Prevention Approved Approved with Conditions' Not Approved (attac co ' ments) REVIEWER'S INITIALS: DATE: 'a 1 6 0 CORRECTION DETERMINATION: Approved n Approved with Conditions \PRROUTE.DOC 5/99 n DATE: Planning Division n Permit Coordinator n No further Review Required DUE DATE 11 -13 -01 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: DUE DATE k -f.i iHveak,, `i v"P•,.Ntdektlire4 s ;�itirztm'2 PERMITNO,: MO1 `� 93 ..� MECHANICAL PERMIT APPLICATIONS INSPECTIONS 00002 Pre- construction 00050 WSEC Residential 00060 WA Ventilation /Indoor AQC 00610 Chimney Installation /All Types 00700 Framing 01080 Woodstove 01090 Smoke Detector Shut Off 01100 Rough -in Mechanical 01101 Mechanical Equipment/Controls O 01102 Mechanical Pip /Duct Insul • 01105 Underground Mech Rough -in O 01 115 Motor Inspection 0/ 1400 Fire Final 1800 Final Mechanical 04015 Special -Smoke Control System CONDITIONS 0001 No changes to plans unless approved by Bldg Div • 0014 Readily accessible access to roof mounted equipment • 0016 Exposed insulation backing material 0019 All construction to be done in conformance w /approved plans O 0002 Plumbing permits shall be obtained through King Co 0027 Validity of Permit 0003 Electrical permits obtained through L & I O 0036 Manufacturers installation instructions required on site O "BTU maximum allowed per 1997 WA State Energy Code" O 0041 Ventilation is required for all new rooms & spaces 0005 All permits, insp records & approved plans available O "Fuel burning appliances O "Appliances, which generate...." O "Water heater shall be anchored...." Additional Conditions: TENANT NAME: V 5,,_... C 4- 5ifecosiao FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace /Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended /Wall /Floor- mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP/1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 din (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) Add'I Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'I Plan Review (hrs) Plan Reviewe Permit Tech: Date: Date: TUES /THURS ROUTING: Please Route Approved CORRECTION DETERMINATION: Approved I I \PRROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M01 - 193 DATE: 10 -15 -01 PROJECT NAME: -U.S. COURTS EXPANSION SITE ADDRESS: 14240 INTERURBAN AVENUE SOUTH XX Original Plan Submittal Response to Incomplete Letter # Response to Correction. Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division n Fire Prevention le Public Works Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Incomplete n Structural Review Required REVIEWER'S INITIALS: G APPROVALS OR CORRECTIONS: (ten days) REVIEWER'S INITIALS: Approved with Conditions REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 10-16-01 Not Applicable \ IA . Comments: No further Review Required n /0--fi, DATE: DUE DATE 11 -13 -01 Approved with Conditions n Not Approved (attach comments) n DATE: DUE DATE Not Approved (attach comments) n DATE: Project Name/jena • ,C�P44A,5)0/ I..1.5. C,ouI' - 1 - S _ „ . I f • 1 , 1 .. f 1 4 i�,l�� �.. � 4�,...Y �a,� r,. c sfr t, I ti � ;:", 1 � ,�J, 1 , t�r�r.. ,. '.. Value of Mechanical Equipment: Site Address : , 1 19 '2- Z� e O r ct A) AA So . City State/Zip: ;�,&. -;l4 Tax Parcel Number: 3T3 'O- M(( -0 Van ATO- cool-r Prope y O wn e ' C---° ,O I1 4 / /) _ 0 Print name: rn to Phone: ( ►fig ) 4/55-12q 2 Str je� : &/ r- Re _I Rd / DI • 0 / )� evti C_ ity State2ip: (.v2 gSooS Fax #: ( ) Contractor: e ; Cr / W t )C � / N l Address: 9 ��d r S Phone: (y25) g b'3 • qZZ Street Addre s r d q 3v X 53 Ate, N n _ _ City State/Zip f0N , 12& '1905 L Fax #: (IiZ5 ) g95-909•2_ ContactPerson: J / . l _ vl / - Phone: (L/25) (,p2 -3V z Street Address: MGr 1 ' /144c A. ) Gtr ) City State/Zip: Fax #: ( ) , T i l ;�BU1L` DING „OWNER�'OR.AUTHORIZED.A'GENT � -� •` . .. �. . ,1, �I . � .... w ..1 , 1. , t ,.. .�. „ . I f • 1 , 1 .. f 1 4 i�,l�� �.. � 4�,...Y �a,� r,. c sfr t, I ti � ;:", 1 � ,�J, 1 , t�r�r.. ,. '.. Signature: Date: / 1 _ 0 Print name: rn to 1/ Iu i l S Phone: (�� _ Fax Fax #: ( ) Address: 9 ��d r S ` '� p city/state/zip: f1 n fi tt ,.. a ( i ) A- Mechanical Permit Application ai,MECHANICAL', AND "APPROVAL REQUESTED: (TO BEF /LLED,' "OUT`B1�' APPLICANT), :'il:'.i'"t �,',.,i' Description of work to be done (please be specific): 4\0, t- 2-efv t iA s crossov-fr Rofinet Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 11/2/99 meth pern s,doc )cal 2 3 CITY OF TI WILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Number. Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: 4 415.110 A Application taken by: (initials) �i� ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL : Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat loss calculations or Form H -6. Equipment specifications. Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. 11/2/99 miscpml.do• Change -out or replacement of existing mechanical equipment I Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water. heaters or vents being installed or replaced. • et 11 y T t .,1 Y t. ' :d 1/41. '' t3' •.n r • CITY OF TUKWILA Address: 14240 INTERURBAN AV S Suite: Tenant: US COURTS Type: B-MECH , Parcel W: 336590-1881 •.erpit Conditions: Electrical permits shall be obtained through the Washington State Division of Labor and and all electrical ''work will be inspectWbYtthat:agentkj248-6630). 2. ;No changes will.be, made to the plans unless approved by the r 1 -Engineer and * the'jukwila Building Division. 3. All permitsi;,in'ipection,Ocords, and approved plans shall be available.,:at-thejob site prior tO the start of anY_con- struction.: Thesedocumentsare to be Maintained and avail- , able urft0 final inspection approval is granted. , '.. All cdnStructidn'to,be done in'conformance with approved plan*,,aild requirements of the Uniform Building Code (1997 Edie10 amended, ,Uniform Mechanical Code (1997,Edition), , andfWashiqgton Energy Code (1997 Edition) ...,. . 5. Validity of PermitThe issuance of a permit or approval of plans, specifications, and computations shall not he con-%; 0:45uedNtp perikit for, or an approval of, any violation, dtoany of the provi-sions of the 'building code or of any other ordinance of the Jurisdiction. No permit presuming to give •uthority to ,violate or cancel the provisions of this code shall be'valid. Manufacturers installation ,instructions required on site , for the 'building 'Inspectors review. I here that I have read these condition s and will comply . - with them as,,out,lined. All provisions of law and ordinances governing this work willbe complied with, whether specified herein or not'. • Permit. No: M01-193 Status: Applied: Issued: ISSUED 10/15/2001 10/17/2001 The granejng of this permit does not presume to give authority to - - violate or'cancei' the provisions of any other work or local laws . , regulatingponstri!ption or the performance of 'Work.' ignature: Date': Pr'int Name: . • . . ;$' ........................... TITN TRAUSMIT'Aamb T4lyment:%Mth iriu it: Site uJcIre t 0.00) 00.0)322. 100 r t • ■ 7 V• ; .1t 4 1 .4 10 4 4.:4i 4, • •' :231 ' • f " . . , .% • • • tiisk4c4.**44*4.*4 **.A*4 A. WA TRANSMIT 44.k4* *4•4**,44 Aic4),*4*11/4***4 *If 4 3kir*****47ir ktic/ri er; R0101347 Amount: 46.50 10/17/01 1052 fad: CHECK Nutiltion: MERIT MECHAN3CAL In it. KAS Not M01-193 Type: B-MECH MECHANICAL PE1Ml7 No: 336590-1861 ts: 1,4246 INIERURBAN AV S fotal Foes: 4t).50 46.50 Tuf0 ALL. Pmts..: 46.50 Balance: .00 AA4 iti14411.**4 4)%A*4714A*4444***44****4441k#444444 IN.+44i44% .Description PLAN CHECK NONRES MECHANICAL -- tODWRES _ 01 la 10/19 9710 TOTAL 46050 • • • 7.• • . • . • .. • • . . • • „ . , • ,,, • • . Amount 9.30 37.20 ' ‘... • - • ,,, - • .• • ' ' ••■.' • )■'•••• :a:- • •-‘,"3•4-4 t,••••• • ; ;•-r• 0-• P9'ect: t _ c 1)01 -t- 6.0 .e of Irppectio Ktt)C r, n: Ft wt. I / dress IL1, 1 --10 Snm+rkrin ichl -. c ed: i 10 - 2-7/ 0 1 Special instructions: Date w ted: / 3 1 ( : 1". . Rei cu.te .ter,:, V.,..t. A A-4 4o t Phm • 10 — I& ig s 7-1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Ocivo P I p-r — / r‘i GA/.5 2- PERMIT NO. (206)431-3670 Corrections required prior to approval. - PP mi.g7 Date: specto : • , 7 .00 REINSPECTION EE REQUIRED. P ior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100.. Call to schedule reinspection. Receipt No: Date: ■••, e••• , — • • ..■• :•• . .-. r ey.::'':r. w ± , Typg R4a Date called: -I - • 0 01' -,,,,,,,, . ..., _......;,. ,-; • ::- , tf AI 0 — 4 Special instructions: '':.•_.' .".. ; .='i' <31 Date wanted: jo723 1 ( P.m. Requester: ., 0q*.e Phone: . • , • • • " I . • : „., „ • " t • INSPECTION RECORD Retain a copy with permit INSPECTION. NO. CITY OF TUICWILA BUILDING DIVISION 000 Southcenter Blvd, #100, Tukwila, WA 98188 MMENTS: , `Ornivi.W )2619fre7 ..-z_i e70/ % , . i'S /1 f el --/— 6" ) :Od PAA€ fr;fr 5 .. - oz...)e 1 tf-7 1, /2000 _ coec- etis -i 9-. )/A 1 /1/ A / Xpproveci per applicable codes. Corrections required prior to approval. PERMIT NO. (200 & P /1/ S D A3 ate: .99 REINSPECTION E REQUIRED. Pri to inspection, fee mZt be paid it6300 SmithCenter Blvd., Suite 100. Cali o schedule reinspection. ReCe1Pt Date: ' • • '," - ■ -; - ' F625.052.000 (8191) PARtMENTOFLABOWANDIt4DUSTRIES . „ • . • . REGISTERED AS PROVIDED .BY LAW.AS / CONT GENERAL • . ..40: • .3. • • • " • n ••• • , ..;■• - • • • ) " r MERIT MECHANICAL P0130X - • REDMOND WA 98073-2109 - mePir MI I C JY Notary Public in and for the State of Washington residing in Redmond. 67/ I certify that this is a true and correct copy of an original license. M01- 113 Balance Due: $ Need Current Contractor Registration Card: Need to Enter. Contractor Information in Sierra: Yes [) No Yes ❑ No rk��GQnta krats L GENERAL A. VERIFY AND CONFIRM ALL DIMENSIONS AND EXISTING CONDITIONS. NOTIFY OWNERS REPRESENTATIVE FERRARI DESIGN GROUP (FDG) OF ANY DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN OR PROGRESS OF WORK. PRIOR TO PROCEEDING WITH THE ITEM OF WORK AFFECTED. B. COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. LAWS AND ORDINANCES GOVERN IN CASE OF CONFLICT BETWEEN METHODS OR STANDARDS OF INSTALLATION OR MATERIAL QUALITY. NOTIFY (FDG) OF ALL CONFLICTS. ALL WORK SHALL CONFORM WITH THE PM UBC AS AMENDED AND ADOPTED BY THE CITY OF TUKWILA. C. OBTAIN SEPARATE PERMITS FOR ALL ADDITIONS AND /OR MODIFICATIONS TO: I. MECHANICAL 2. ELECTRICAL 3. FIRE SPRINKLERS 4. FIRE ALARMS/PROTECTION IN ACCORDANCE WITH AND AS REQUIRED BY ALL CODES AND REGULATIONS. D. COMPLY WITH REQUIREMENTS IN THESE SPECIFICATIONS FOR STANDARD OF WORKMANSHIP, PERFORMANCE, AND QUALITY. I. WHERE MATERIALS, FINISHES OR EQUIPMENT 15 NOT SPECIFICALLY IDENTIFIED, THE CONTRACTOR WILL BE REQUIRED TO SUBMIT SAMPLES OR INFORMATION DETERMINING QUALITY AND PERFORMANCE TO OWNER/TENANT PRIOR TO ANY WORK.'. E. COORDINATE SUPPLIERS AND SUBCONTRACTORS FOR PROPER SEQUENCE OF OPERATIONS, PREVENT DUPLICATION OF EFFORT; PROVIDE ORDERLY PROGRESS OF WORK; F. MAINTAIN STRUCTURAL INTEGRITY OF BUILDING E +,/ELL. ANY SUPPORT OF NEW EQUIPMENT BY SHELL STRUCTURE SHALL BE REVIEWED AND APPROVED BY A WASHINGTON STATE LICENSED STRUCTURAL ENGINEER. CALCULATIONS AND DETAILS SHALL BE PROVIDED FOR PERMIT SUBMITTAL PURPOSES. 6. GLEAN UP. I. DAILY SIT- CLEANUP: ALL RUBBISH MUST BE REMOVED AT THE END OF EACH WEEKDAY AND, WHERE THE SPACE 15 CURRENTLY OCCUPIED, VACUUMED IN THE IMMEDIATE WORK AREA. 2. FINAL CLEANUP: SCOPE OF CONTRACTOR'S WORK TO BE A COMPLETE TURNKEY CLEANUP OF THE ENTIRE TENANT SPACE INCLUDING, BUT NOT LIMITED TO, ALL FLOOR COVERINGS, INTERIOR WALLS AND GLAZING, INSIDE SURFACE OF EXTERIOR GLAZING, AND DOORS. CLEANUP IS NOT LIMITED TO THE IMMEDIATE WORK AREA. DUMPSTERS: CONTRACTOR TO PROTECT ASPHALT SURFACES WITH WOOD BLOCKING OR SKIDS TO PREVENT DAMAGE TO THE PAVED SURFACES. 2. SITE WORK. NONE REQUIRED 5. CONCRETE, NONE REQUIRED 4, MASONRY, NONE REQUIRED S. METALS A. FRAMING. "GRABBER' OR EQUIVALENT, AS DETAILED ON DRAWINGS, WITH FIRE BLOCKING AS REQUIRED BY GODS. BOTTOM PLATE CONNECTION AT 24" O.G., INTO EXISTING WOOD DECK. B. FURRING: "GRABBER OR EQUIVALENT, AS DETAILED ON DRAWINGS. FUR OUT RAIN LEADERS, CONCRETE PILASTERS AND COLUMNS AND SHIM CONNECTOR PLATES, ETC. A5 REQUIRES TO COVER. G PROVIDE GALVANIC. INSULATION BETWEEN DISSIMILAR METALS WHERE IN CONTACT. 6. CARPENTRY A. GENERAL: PROVIDE BLOCKING AS REQUIRED FOR FIXTURES, ACCESSORIES, GRAB BARS, ETC. B. CABINETRY, NONE REQUIRED C. DRAFTSTOPS: EXIST516 -NO NEW WORK 7. THERMAL AND MOISTURE PROTECTION A. INWLATION: EXISTING NO NEW WORK REQUIRED B. ROOFING: I. FLASH AND COUNTERFLASH ANY AND ALL PENETRATIONS OF ROOFING. ROOF PAT,f4ING MUST BE ASPHALT BASE MATERIAL COMPATIBLE WITH EXISTING ROOFING. 2. PLACE ROOF MOUNTED EQUIPMENT ON CURBS WITH SLOPES AS REQUIRED FOR PROPER DRAINAGE. GANT SIDES OF CURBS, APPLY ROOFING MATERIAL AND MOP OVER. GAP CURB TOP AND CAULK OVER ALL NAILS AS REQUIRED TO ENSURE WEATHERPROOFING. 3. VERIFY CONDITIONS OF BUILDING SHELLPROOF WARRANTY. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH TERMS OF THE WARRANTY TO INSURE THAT CURRENT WARRANTY REMAINS IN FORGE. 6. DOORS, WINDOWS, HARDWARE A. DOORS: 3' -0" BY T' -O ", I -3/4" THICK SOLID GORE, UNLESS NOTED OTHERWISE MATCH EXISTING BUILDING STANDARD I. AL EXIT SHALL BE OPENABLE FROM THE INSIDE WITHOUT USE OF KE. OR ANY SPECIAL KNOWLEDGE OR EFFORT. MATCH EXISTING BUILDING STANDARD. 2. FURNISH RATED ASSEMBLIES WHERE NOTED ON DRAINING A2 FLOOR PLAN. B. FRAMES: MATCH EXISTING BUILDING STANDARD. C. HARDWARE: MATCH EXISTING BUILCING STANDARD I. ALL HARDWARE- BY SCHLAGE LOCK COMPANY. OR EQUA, AS APPROVED. 6Y OWNER AND TENANT AS TO FINISH, LOCK FUNCTION, ETC. MATCH EXISTING BUILDING STANDARD. 2. ALL HARDWARE USED IN ACCESSIBLE BUILDINGS AND FACILITIES SHALL CONFORM TO THE REQUIREMENTS' PER "WASHINGTON STATE RULES AND REGULATIONS FOR BARRIER FREE DESIGN (WAG- 3I -30) CHAPTER II. 3. VERIFY KEYING REQUIREMENTS. SPECIALTY ITEMS AND QUANTITIES REQUIRED FOR COMPLETE INSTALLATION PRIOR TO ANY WORK. TENANT IMPROVEMENTS FOR: US COURTS EXPANSION FAIRWAY CENTER BUILDING 'B' 14240 INTERURBAN AVENUE SOUTH, TUKWILA, WASHINGTON 98168 CITY OF TUKWILA GENERAL NOTES D. GLAZING I. PROJECT GLAZING SUBJECT TO FEDERAL GLAZING STANDARDS AND GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS OF CHAPTER 24 UGC. 2. ANY MODIFICATION OR ADDITION TO STOREFRONT FRAMING AND GLAZING SHALL MATCH EXISTING STOREFRONT SYSTEM. 9. PINISFEB A. FLOORING (REFER TO PLAN ON DRAWING A21 I. CONTRACTOR WILL BE REQUIRED TO FIELD VERIFY EXISTING SLAB/SUBLOOR CONDITIONS. ANY SLAB/SUBPLOOR PREPARATION REQUIRED PRIOR TO INSTALLATION OF FINISH FLOOR MATERIAL 15 WITHIN THE SCOPE OF WORK. 2. CARPETING: MATCH EXISTING CARPETING IN AREAS WHERE NEW CARPETING IS INSTALLED. 3. VINYL COMPOSITION TILE: NONE REQUIRED 4. SHEET VINYL: NONE REQUIRED 5. BASE: 4" ROPPE VINYL: BASE IN COLOR COORDINATED WITH FLOORING. SEE PLAN ON DRAWING A2 FOR ADDITIONAL' INFORMATION. B. GYPSUM WALLBOARD: I. 5/8" GYPSUM BOARD, TAPED AND READY FOR PAINT.:. 2. ATTACH TO FRAMING/FURRING WITH I GAB. SCREWS AT 8" D.G. AT PANEL EDGES AND 12" O.C. AT INTERIOR SUPPORTS. B. 5/6" TYPE 'X' GYP BOARD AT ALL RATED ASSEMBLIES IDENTIFIED ON DRAWINGS. C. PAINT: KELLY MOORE OR APPROVED EQUAL. I. GENERAL WALLS: ONE GOAT LATEX PRIMER AND TWO GOATS•INTERIOR LATEX EGGSHELL ENAMEL. 2. DOORS AND FRAMES, STAIN AND VARNISH ALL WOOD DOORS AND FRAMES TO MATCH EXISTING BUILDING STANDARD. SUSPENDED CEILINGS. (EXISTING TO BE REPAIRED AND TILES REPLACED AS NECESSARY) I. LAY -IN ACOUSTICAL BOARD: ARMSTRONG "MINABOARD ": 2'X4'X5/8" FISSURED PATTERN. VERIFY/MATCH WITH EXISTING BUILDING STANDARD. 2. SUSPENDED SYSTEM: 2'X4' HEAVY -DUTY COMMERCIAL 11/2" MAIN AND INTERMEDIATE TEES. NO. 12 GAUGE HANGERS AT 4 ON CENTER EACH WAY PER USG STANDARD, CAPABLE OF SUPPORTING 160 POUNDS. ATTACH HANGERS TO STRUCTURAL FRAMING MEMBERS WITH 1/4" SCREWS PENETRATING 11/4" INTO STRUCTURE. MATCH EXISTING EUILDIN6 STANDARD. 3. SUPPORT LIGHT FIXTURES WITH TWO NO. 12 CAUSE HANGERS FROM FIXTURE TO STRUCTURE ABOVE. LIGHT FIXTURES WEIGHING MORE THAN 56 POUNDS SUPPORTED BY 4 HANGERS, ONE IN EACH CORNER. 4. CEILINGS HORIZONTAL TO A TOLERANCE OF I /6" IN 10'-0" MEASURED EACH WAY. GRID TO REMAIN A CONTINUOUS PATTERN THROUGHOUT. 5. SEISMIC BRACING AS AS REQUIRED BY MC. 15 EXISTING TO REMAIN. 10. SPECIALTIES A. FIRE EXTINGUISHERS. (EXISTING) PROVIDED. PER CODE. 1 PER 5000 5F. OF FLOOR AREA, WITHIN A MAXIMUM T5' TRAVEL DISTANCE FROM ANY POINT. II. EQUIPMENT NONE REQUIRED 12. FURNISHINGS, NONE REQUIRED 15. SPECIAL CONSTRUCTION. NONE REQUIRED 14. CONVEYING SYSTEMS. NONE REQUIRED 15. MECHANICAL (BY SEPARATE PERMIT) A. PLUMBING: NONE REQUIRED B. 6A5 PIPING, NONE REQUIRED G. HEATING, VENTING AND AIR CONDITIONING: ROOF TOP UNITS - GAS HEATING ELECTRIC AIR CONDITIONING. MODIFICATION OF EXISTING SYSTEM AND INSTALLATION OF NEW EQUIPMENT AS NECESSARY TO BE DONE UNDER SEPARATE MECHANICAL PERMIT. i6. ELECTRICAL. (BY SEPARATE PERMIT) EXISTING. OUTLETS, SWITCHES, SERVICE, TO REMAIN - ADDITIONS/MODIFICATIONS UNDER SEPARATE PERMIT AS DIRECTED BY TENANT /OWNER AND AS NOTED ON PLAN. A. POWER PANEL: VERIFY LOCATION, SIZE AND CONFIGURATION OF EXISTING SERVICE B. OUTLETS AND WIRING INSTALL NEW OUTLETS AS DIRECTED BY TENANT IN ACCORDANCE WITH ALL APPLICABLE CODES. VERIFY DEDICATED CIRCUIT LOCATIONS WITH TENANT. ALL CONDUCTORS SMALLER IN SIZE THAN A 46 SHALL BE COPPER TERMINATE ALUMINUM CONDUCTORS WITH GABLE TERMINATORS/DURESS ALARM SYSTEM. G. TELEPHONES: INSTALL NEW PULL WIRES IN WALLS TO NEW LOCATIONS AS DIRECTED BY TENANT AND AS NOTED ON PLAN. ALL WIRING AND INSTALLATION OF TELEPHONE AND ALARM SYSTEM IS N.I.G. (BY TENANT) D. COMPUTER DATA LINE: TO BE COORDINATED AND INSTALLED BY TENANT UNDER SEPARATE CONTRACT. E. POWER POLES: NONE REQUIRED. F. LIGHTING: EXISTING TO REMAIN OR BE RELOCATED PER PLANS. I. GENERAL. 2'X4' 3 -TUBE LAY -IN ENERGY EFFICIENT FLUORESCENT FIXTURES. WITH ELECTRONIC BALLASTS. REFER TO REFLECTED CEILING PLAN. 2. LAMPS: F32T8/SP41 OR APPROVED EQUAL. WASHINGTON STATE NREG INFORMATION - 1 EDITION ALL WORK OF THIS PERMIT 15 BEING PERFORMED WITHIN AN EXISTING, FULLY HEATED, INSULATED BUILDING. NO MODIFICATION 15 PROPOSED TO BUILDING ENVELOPE. OkEER, TENANT. PROJECT CONTACTS RJ. HALL155EY COMPANY 12835 BEL -RED ROAD. SUITE 4 ,40 BELLEVUE. WASHINGTON 96005 PHONE. (425) 455 -9292 FAX: (425) 455 -2016 CONTACT, LEE SHEPHARD U5 COURTS 14240 INTERURBAN AVENUE SOUTH TUKWILA, WASHINGTON 96168 PRO.I.T A.DDI., 14240 INTERURBAN AVENUE SOUTH, TUKWILA, WA 96168 TAX PARGEL NOa •536590- 1811-06 /00280- OOOI -00 TENANT AREA, APPROX. Sp30 S.F. TOTAL ENDO. AREA. APPROX. 51;122 S.F. (BUILDING 'B') AONSTRUGTIONI TYPE. TYPE VN SPRINKLERED SITE ION.. MI OGGI,PA AY, B, OFFICE Al A2 WORK UNDER THIS PERMIT WORK OF THIS PERMIT WILL BE LIMITED TO THE DEMOLITION OF 16 LIN. FT. OF EXIST.. OFFICE PARTITION CONSTRUCTION OF 1100 LIN. FT. OF NEW OFFICE PARTITION AND INSTALLATION OF FOUR NEW 3'-0"X7' -0" DOORS AND THREE FULL HEIGHT SIDE LIGHTS AT NEW DOORS. SHEET INDEX COVER SHEET FLOOR PLANS AND DETAILS. ARCHITECT, FERRARI DESIGN CROUP 1227 154TH COURT NE, SUITE 203 REDMOND, WASHINGTON 96052 PHONE: (425) 621 - 3383 FAX: (425) 821 -3213 EMAIL. NerrarldcelynoearthllnKnet CONTACT. FRANK HEFFERNAN, AIA GENERAL CONTRACTOR, PROJECT DATA MMI SERVICES INC. 245 EAST ONSET WAY ISSAQUAH, WASHINGTON 96027 PHONE, (425) 369 -8655 FAX. (425) 369 -6656 LICENSE NO: MMISCIA094P5 CONTACT, BRYAN MOORMAN D(iq3 VICINITY MAP SCALE, NO SCALE Date Permit No VICINITY MAP SCALE, NO SCALE LEGAL DESCRIPTION LO - 1.1 - ,13L'DCRTFFEttlL t Rj T SEATTLE CARD N TRACTS. understand that the Plan Check approvals are subject A errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged -7 7.3 Stint. BE MADE TO 3Tio WY101 A NEw ltlyuFFE9,u SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL g ELECTRICAL IS� LUMBING 'GAS PIPING CITY OF TUKWILA BUILDING DIVISION RECENED amoPTUNwlu PERMIT CENTER ARCHITECT: PROJECT: 00Z'` : t 3 FERRARI D ESIGN G ROUP ARCHITECTS, PS 12277 134TH COURT NE SUITE 3203 REDMOND, WASHINGTON 98052 -2433 (OFFlCEI 625821 3383 (FAX) 625.821.3213 (EMAIL) feneriE04ip.�enM14nk net US COURTS EXPANSION Fairway Center Bldg. 'B' 14240 Interurban Ave. South Tukwila, Washington 98168 SHEET INFORMATION: PLANS; DETAILS OWNER: R.J. HALLISSEY COMPANY 12835 Bel -Red Road Suite #140 Bellevue, Washington 98004 TENANT: US COURTS 14240 Interurban Ave. South Seattle, Washington 98168 REVISIONS: ott c: aVnm»s\ .R015, GA NA. F.HEFFERNAN Mum By. H. YAMANUTO RNA AUGUST 31.2001 Sheol No.: PERMIT DRAWINGS Al LEGEND EXISTING WALL TO REMAIN. EXIST.N6 WALL TO BE REMOVED. NEW WALL PARTITION PER DETAIL 1 /A2. BUILDING GRIDLINE. CEILING GRID. EXISTING 2x4 (3) TUBE RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN. EXISTING 2X4 (3) TUBE RECESSED FLUORESCENT LIGHT FIXTURE TO BE REMOVED/RELOCATED. LOI EXISTING 2X4 (3) TUBE RECESSED FLUORESCENT LIGHT FIXTURE NEW LOCATION. DETAIL DESIGNATION. <>—\ ® EXIT SIGN. KEYNOTE DESIGNATION. LIGHT SWITCH (E' NEXT TO SYMBOL DESIGNATES EXISTING TO REMAIN) TELEPHONE/DATA OUTLET (E'NEXT TO SYMBOL DESIGNATES EXISTING TO REMAIN) OUADPLEX OUTLET ('E' NEXT TO SYMBOL DESIGNATES EXISTING TO REMAIN) DUPLEX OUTLET ('E' NEXT TO SYMBOL DESIGNATES EXISTING TO REMAIN) DURESS ALARM OUTLET W/R)LL STRING KEYNOTES k I. EXISTING 3' -0 "X7' -0" SOLID GORE DOOR AND FRAME TO REMAIN. 2. NEW 3' -0,1 -0' SOLID GORE DOOR AND FRAME TO MATCH 15UILDIN6 STANDARD. S. EXISTING 5'-0"X1' -0" SOLID LORE DOOR AND FRAME TO MATCH BUILDING STANDARD. 20 MIN. RATED ASSEMBLY FOR ONE HOUR CORRIDOR. HARDWARE TO MATCH EXISTING ENTRY DOOR AND PER TENANT DIRECTION. 4. NEW 2'-0'X1' -0" TEMPERED GLASS RECITE TO MATCH BUILDING STANDARD. 5. EXISTING 2'- 0'XT-0" TEMPERED GLASS RECITE TO REMAIN. 6. EXISTING CARPET TO REMAIN. REPAIR/PATCH WHERE NECESSARY. (OR NEW CARPETING PER TERMS OF LEASE AGREEMENT) T. INFILL OF WALL OF ONE HOUR CORRIDOR SHALL CONFORM TO UBC TABLE TB, ITEM I6 -I.1 5/8" TYPE 'X' GYP 6D. EACH SIDE OF 0.018 (25 6A) STUDS 6 2' -0" O.G. 20 6A. 5 5/8" METAL SND BRAGIN6 TO STRUCTURE AT 8' -0" O.G. 1.1/(2) 6 8 SHEET METAL SCREWS AT EACH END. BRACING TO BE PROVIDED WHERE DISTANCE ETWEEN PERPENDIO'JLAR INTERSECTING WALLS OR HORIZONTAL BRACING BETNEEN WALLS EXCEEDS 8' -0' O.G. EXISTING FIBERGLASS BATT TYPE INSULATION HAS BEEN INSTALLED AT UNDERSIDE OF ROOF STRUCTURE UNDER PREVIOUS PERMITS. — SUSPENDED ACOUSTICAL CEILING BOARD. ATTACH TOP TRACK TO MAIN RUNNER OR GROSS TEE • POINT OF INTERSECTION W/(I) TYPE "S" SCREW. 5/8" 6W5 EACH SIDE ATTACH WT'PE SCREWS a 8" PANEL EDGES 4 12' FIELD. 1/2 "x25 6A METAL SND a 24 0.C. ATTACH 20 GA BOTTOM TRACK 6 24" . INTO . EXISTING WOOD DECK AT SECOND FLOOR TYP. OFFICE WALL PARTITION SCALE: I I /2' • I' 0" 0- US CCUIRTS1, ADJACENT TENANT LEASE SPACE LEASE SPACE 60+-0" DEMOLITION FLOOR PLAN SCALE: I /8' • I' -O" WALL /MULLION DETAI L O OFFICE Li L WORK RM. OFFICE OFFICE CONFERENCE RM. 30'-0" OFFICE SUPPLY RECORDS OPEN OFFICE AREA RECEPT OFFICE BUILDING COMMON CORRIDOR OPEN OFFICEO 4 19'-4" VERIFY 14' -8 VERIFY 60T-0' <5' SECOND FLOOR PLAN SCALE: I, • NO" OFFICE AR WAITING G I . 1 6 E > hew Iocotevr5 SECOND FLR. REFLECTED CLG. PLAN SCALE, I/D • I -0 US COURTS ADJACENT TENANT LEASE SPAC LEASE SPACE ADJACENT TENANT ADJACENT TENANT ONYX ENVIRONMENTAL LEASE AREA EUILDINS CO'rIMON CORRIDOR 1 FERRARI DESIGN GROUP ARCHITECTS, PS 12277 136TH COURT NE SURE e203 REDMOND, WASHINGTON 88062 -2433 IDFFICE) 426.821.3333 1FAXI426B21.3213 (EMAIL) fenmkeci8�lerthlink.nn ARCNITECT: PROJECT: US COURTS EXPANSION Fairway Center Bldg. S' 14240 Interurban Ave. South Tukwila, Washington 98168 SHEET INFORMATION: PLANS; DETAILS OWNER R.J. HALLISSEY COMPANY 12835 Bel -Red Road Suite #140 Bellevue, Washington 98004 TENANT US COURTS 14240 Interurban Ave. South Seat0e, Washington 98168 ,re oc wxos Na >K FCC) v INrn 'newel O[Pte E0 vs. OD CD we[x0IeoY IN E0 MR ION n .,anw memo/ my Fm a <xmto. US ADJACENT TENANT LE — ASE SPAGE' 9PAGE CITY OF7UKWILA y oe "li iwo PERMRCENTER a Ch Fsdey. F.VEFFERNMI 8 16 2��t 68 8y itynk MOro O N to' Deb: AUGUST 31.401 t N 5)G1d o C tr ® LL Sheet NO.: PERWTORAWINOS 2 A2 3oDNo: 9404021