Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M06-003 - CROZIER RESIDENCE
CROZIER RESIDENCE 1510251 AV EXPIRED 07 -05 -06 M06 -003 Parcel No.: 9844400045 Address: 15102 51 AV S TUKW Suite No: City hi Tukwila Tenant: Name: CROZIER RESIDENCE Address: 15102 51 AV S, TUKWILA WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: cttukwila.wa.us Owner: Name: SNIDER MICHAEL T +3ENNIFER K Address: 15102 51ST AVE 5, TUKWILA WA Contact Person: Name: PHILLIPE CROZIER Address: 15102 51 AV S, TUKWILA WA Contractor: Name: PERFORMANCE HEATING Address: 7649 5 180 ST, KENT WA Contractor License No: PERFOHA15ORT MECHANICAL PERMIT DESCRIPTION OF WORK: CHANGE OUT EXISTING GAS FURNACE WITH NEW LIKE FOR LIKE Value of Mechanical: $2,000.00 Type of Fire Protection: Furnace: <100K BTU 1 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 Permit Number: Issue Date: Permit Expires On: Fees Collected: $150.63 International Mechanical Code Edition: 2003 EQUIPMENT TYPE AND QUANTITY * *continued on next page ** Phone: Phone: 206 755 -3605 Phone: 425 251 -0356 Expiration Date: 04/29/2007 Steven M. Mullet, Mayor Steve Lancaster, Director MO6 -003 01/06/2006 07/05/2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment... 0 doc: IMC- Permit M06 -003 Printed: 01 -06 -2006 Permit Center Authorized Signature: Signature: doe: IMC- Permit City b? Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Ain I hereby certify that I have read and e*adhined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatin• ,• i It • • • ance of work. I am authorized to sign and obtain this mechanical permit. Steve Lancaster, Director Permit Number: M06 -003 Issue Date: 01/06/2006 Permit Expires On: 07/05/2006 Date: Cl'C P• Date: Steven M. Mullet, Mayor This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M06.003 Printed: 01 -06 -2006 City of tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 9844400045 Address: 15102 51 AV S TUKW Suite No: Tenant: CROZIER RESIDENCE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS * *continued on next page ** Permit Number: M06 -003 Status: ISSUED Applied Date: 01/06/2006 Issue Date: 01/06/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction These documents shall be maintained and made available until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located In, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition Is not less than 18 Inches above the floor surface on which the equipment or appliance rests. 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- Inches shall be maintained above the controls with the strapping. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of Public Health - Seattle and King County (206/296 - 4932). 9: All electrical work shall be inspected and approved under a separate permit Issued by the Washington State Department of Labor and Industries (206/248- 6630). 10: VALIDITY OF PERMIT: The Issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The Issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions M06 -003 Printed: 01-06 -2006 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: • °� Print Name: G �c doc: Conditions Date: t ( ( (A M06 -003 Printed: 01 -06 -2006 CITY OF TUKI&4 Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 **Please Print** Building Permit No Mechanical Permlt.No.: MO U Public Works Permit No Project No Site Address. I s/ d 2 51 Sr A S t Tenant Name: Phi t. C fao2.1 64.- Owners Name- P 1111 r t C(O2s er Mailing Address / & D Z Si S t M- C S- Name: Pk.►ltpt Cro2rer Mailing Address. / S/ a 1- S/ s+ /! ` c S E -Mail Address; Company Name- Mailing Address. Lppiweonyw,mn appliation 11 -200g Page I King Co Assessor's Tax No.: 1 8 7 99 606 IS Suite Number. Floor. New Tenant•. El --Yes ❑..No kwa ►r► City WA 7: / r CONTACT P Zoe. 7S3 34 Day Telephone: 7vrva 1W City Fax Number. wVt State Zip State GENERAL :±CONTRACTOR INFORMATION:.:(Medawar dna ormatunt on baetc pt{Qe): ; l� City State Contact Person: Day Telephone: Telephone: E- hlailAddresa: Fax Number. Contractor Registration Number. Expiration Date: * *Anoriginal or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance** ARCEITECT OFRECORD— .Ulplan smuatbewet :stampedby Architect : arRecortf . Company Name- Mailing Address. City Contact Person: Day Telephone: E -Mail Address:. Fax Number. State ENGINEEROF RECORD w Ail pins must be.wetptamped by tngipeer of Record Company Name- Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number. State 10 T i - ' 8 9 Zip Zip Zip Zip YY TUKWI LA W Unit Type: Qty Unit Type: Qty Unit Type: Qty Boller /Compressor: Qty FurnaceQ00K BTU Y 1 Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace >100KBTU Evaporator Cooler Diffuser 3-15 HP /500,000 BTU Floor Furnace Ventilation Fan Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stave 30-50 HP /1,750,000 BTU Appliance Vent Hood Water Heater 50+ HP /1,750,000 BTU Heat/Reffig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 am Incinerator — Comm/Ind Other Mechanical Equipment 4. t 11lECHANICAL PERMIT IIVI.ORMATION ,r 206. 4313670 ................. MECHANICAL CONTRACTOR INFORMATION PerzfOgivtAkcE 6 Company Name: Mailing Address 762 5 % / %' o Tl Indicate type of mechanical work being Stalled and the quantity below: BUILDING OW AGENT: Signature: Sigmture: Print Name: 7fl b 6»u Mailing Address. S` yo 11 - I . Date Application Accepted: .ppliationatpemit applieetioe (7 -2004) Dt• Paw 4 /Z c r4' V✓ Yr fir City State Zip Contact Person: TObb Vfrgi Day Telephone: 91-f Zr(— 0331, E -Mail Address- PC-1 orat w..e.c. k < .t-1 Cdr Fax Number I ' 2 r 25 1 - olga Contractor Registration Number: 2 FD 1I14 /5 Expiration Date: 71 2 --4 /0 7 "An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance" Valuation of Project (contractor's bid price): S 2 °O C) Scope of Work (please provide detailed information): G if A w6 'C O Litt t?c/S it ^4 6 '1 ` 9 J Firm 4l ; a t1- — i' . W.c -c J t.Ai Lt k-c cvr L t (e 1,1q; Residential: New Replacement g Commercial: New.....❑ Replacement ❑ Fuel Electric ......D Gas....2' Other. PERMIT;APP .ICATIOAI NOTES — (kpplicable to all Permits fa ibis application Value of Construction —in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: hit f /O j Day Telephone: y2 2)' /-63S10 ktA City w k State 9 fa�L Zip - Date Application Expires: Off Staff tnitials V Parcel No.: 9844400045 Address: 15102 51 AV S TUKW Suite No: Applicant: CROZIER RESIDENCE ACCOUNT ITEM LIST: Description City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 MECHANICAL - RES RECEIPT Permit Number: M06 -003 Status: PENDING Applied Date: 01/06/2006 Issue Date: Receipt No.: R06 -00017 Payment Amount: 150.63 Initials: 3EM Payment Date: 01/06/2006 11:48 AM User ID: 1165 Balance: ;0.00 Payee: PERFORMANCE HEATING & AIR CONDITIONING, INC. TRANSACTION LIST: Type Method Description Amount Payment Check 80202 150.63 Account Code Current Pmts 000/322.100 150.63 Total: 150.63 1025 01 /06 9716 TOTAL 150.63 doc: Receipt Printed: 01 -06 -2006 MANE' FURN- PRC001 -EN UpfIOW/Horizon a! Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR80 t TUD040,060,080,100,120,140C Single -Stage Fan Assisted Combustion System 10011000000000 0000000000 0000000000 ®0009000110 0000000000 ®0000000000 11111 1111 11111 BREMEN ° e oc a cc 00 e o eo o o o e oc C o e 00= 11 0== cc o 0 = == CI 0 e c e In Q 9 ter'' st rukwu JAN - 6 2006 PERM T CENTER 0000000000 0011000000008 1 00000000000om 0111100000000m 00000000000000 g 0000000000 I I I 11 Fl I PUB. NO.22- 1640 -06 -0702 (EN) WANE' 0 2002 American Standard Inc. All Rights Reserved General Features Natural Gas Models Central Heating furnace designs are certified by the American and Canadian Gas Associations for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. Safe Operation The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. Quick Heating Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Burners Multi -port In -shot burners will give years of quiet and efficient service. All models can be converted to LP. gas. Integrated System Control Exclusively designed operational pro- gram provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connec- tion points for E.A.C. humidifier. 2 Air Delivery The 4- speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. Styling Heavy gauge steel and "wrap-around" cabinet construction is used in the cabinet with baked -on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Features And General Operation The XR 80 High Efficiency Gas Furnaces employ an adaptive Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter. b. Vent proving pressure switch. 22- 1640 - 06.0702 (EN) 0 TRANS' General Data Product Specifications 0 y MODEL TUD040C924K TUD040C930K TUD060C924K TUDOSOC936K TYPE Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal Upfiow / Horizontal RATINGS OO Input BTUN 40 ,000 40,000 60,000 60,000 Capacity BTUH (ICS) O 32,000 32,000 47,000 47,000 AFUE 80.0 80.0 80.0 80.0 Temp. rise (Min.-Max.) °F. 30.60 30.60• 35 - 65 30.60 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Diameter •Width(In.) 10x6 10x6 70x6 10x7 Eta No. Used 1 1 1 1 Speeds (No.) 4 4 4 4 a PINI CFM vein. w.g. See Fan Performance Table See Fan Performance Table See Fan Performance Table See Fan Performance Table Motor HP 1/5 1/3 1/5 1/3 R.P.M. 1080 1075 1080 1075 ME Volts / Ph / Hz 115/1/60 115/1/60 115/1/60 115/1/60 COMBUSTION FAN -Type Centrifugal Centrifugal Centrifugal Centrifugal Drive - Na Speeds Direct -1 Direct -1 Direct -1 Direct -1 Moor HP - RPM 1/50.3000 1/50 - 3000 1/50 - 3000 1/50.3000 Vohs / Ph / Hz 115/1/60 115/1/60 115/1/60 115/1/60 FLA 1.0 1.0 1.0 1.0 FILTER — Furnished? Yes Yes Yes Yes Type Recommended High Velocity High Velocity High Velocity High Velocity HI Vel. (No.Size-Thk.) 1 - 17x25.1 in. 1.17x25.10. 1.17x25. lin. 1 - 17x25.1 in. VENT — Size (In.) 4 Round 4 Round 4 Round 4 Round HEAT EXCHANGER Type -Fired Aluminized Steel - Type I Aluminized Steel - Type I Aluminized Steel • Type I Aluminized Steel - Type I - Unfired Gauge (Fired) 20 20 20 20 ORIFICES — Main Nat. Gas. Oty. —Drill Size 2 -45 2 -45 3 -45 3 -45 LP. Gas Oty.— DrillSize 2 -56 2 -56 3 -56 3 -56 GAS VALVE Redundant - Single Stage Redundant - Single Stage Redundant - Single Stage Redundant - Single Stage PLOT SAFETY DEVICE Type Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition BURNERS —Type Multi-port In-shot Multi-port In -slot Multi-port In -shot Multi-port In -shot Number 2 2 3 3 POWER CONN. —V / Ph / Hz 0 115/1/60 115/1/60 115/1/60 115/1/60 Ampacity (In Amps) 63 6.3 10.4 10.4 Max. Overcurrent Protection (Amps) 15 15 15 15 P1PE CONN. SDP (IN.) 172 172 112 1/2 DIMENSIONS HxWxD HxWxD HxWxD HxWxD Crated (In.) 41.3/4x16. 12x30.1/2 41- 3/4x16- 12x30 -1)2 41.3/4x 16-1/2 x 30-1/2 413/4x16. 1/2x30 -1/2 WEIGHT Shipping (Lbs.) / Net (Los) 119 / 110 122 / 113 124 / 115 127 / 118 OO Central Furnace heating designs are certified by AGA and CSA. ® For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. O Based on U.S. government standard tests. O The above wiring specifications are in accordance with National Electrical Code; however, Installations must comply with local codes. 6 22-1640-06-0702 (EN) FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (Ins. w.g.) MODEL SPEED TAP 0.10 I 0.20 I 0.30 I 0.40 I 0.50 I' 0.60 I 0.70 I 0.80 I 0.90 4 - HIGH - Black 1018 1004 982 950 910 860 - 802 763 660 TUD040C924K 3 - MED.-HIGH - Blue 2 - MED. -LOW - Yellow 847 716 832 701 809 678 779 648 742 610 697 585 644 512 585 452 517 384 1 - LOW - Red 617 599 575 544 • 507 463 413 357 294 4 - HIGH - Black 1307 1262 • 1211 1164 1092 1023 949 869 783 TUD040C930K 3 - MED: HIGH - Blue 2 - MED. -LOW - Yellow 1172 1030 1140 1007 1100 976 1053 938 996 893 937 840 867 779 791 712 707 636 1 - LOW - Red 892 876 856 893 789 744 691 630 561 4 - HIGH - Black 1013 997 973 941 901 852 796 731 659 TU DO60C92 4K 3 - MED.-HIGH - Blue 2 - MED. -LOW - Yellow 835 712 821 702 800 683 771 655 734 617 689 571 636 516 575 452 506 379 1 - LOW - Red 611 596 573 543 505 459 406 345 277 4 - HIGH - Black 1426 1389 1345 1298 1236 1171 1099 1020 934 TUD060C936K 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 1243 1042 1225 1039 1197 1027 1160 1005 1113 973 1057 931 991 879 916 817 831 745 1 - LOW - Red 900 903 895 877 848 809 760 700 629 4 - HIGH - Black 1115 1094 1060 1014 956 886 803 708 600 TUD080C924K 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 919 772 912 - 767 891 750 857 722 809 681 747 629 671 565 582 489 478 401 1 - LOW - Red 643 655 648 622 577 512 428 325 203 4 - HIGH - Black 1393 1384 1364 1335 1296 1247 1189 1120 1042 3 - MED.-HIGH - Blue 1210 1209 1198 1177 1147 1107 4058 999 930 TUD080C936K 2 - MED: LOW - Yellow 1046 1052 1047 1033 1008 963 928 873 808 1 - LOW - Red 900 903 895 888 869 842 808 766 717 4- HIGH - Black 1839 1821 1796 1756 1710 1641 1573 1480 1392 TUD080C948K 3 - MED HIGH - Blue 2 - MED- LOW - Yellow 1323 1092 1325 1090 1329 1091 1319 1083 1308 1078 1275 1059 1246 1040 1201 1005 1165 970 1 - LOW - Red 788 783 780 768 758 737 719 647 630 4- HIGH -Black 2308 2281 2254 2209 2163 2095 2026 1950 1873 3 - MED.-HIGH - Blue 2006 1997 1987 1960 1933 1888 1842 1780 1718 TUD080C960K 2 - MED.-LOW - Yellow 1690 1691 1691 1683 1674 1651 1627 1556 1485 1 - LOW - Red 1437 1437 1437 1434 1431 1418 1404 1369 1334 4- HIGH - Bla k 1476 1464 1441 1408 1363 1307 1241 1163 1074 TUD100C938K 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 1249 1020 1257 1046 1252 1058 1234 1050 1203 1028 1158 990 1101 936 1030 866 946 780 1 - LAW - Red 873 887 890 883 864 834 794 742 680 4 - HIGH - Black 1771 1731 1355 1624 1556 1479 1392 1296 1191 TUD100C945K 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 1375 1127 1371 1141 1328 1124 1328 1124 1289 1094 1238 1049 1176 989 1102 914 1016 825 1 - LOW - Red 780 815 829 822 796 749 681 593 485 4 - HIGH - Black 1880 1846 1799 1740 1669 1595 1489 1381 1280 TUD100C948K 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 1662 1428 1635 1421 1598 1402 1551 1370 1493 1326 1424 1269 1345 1199 1256 1117 1157 1022 1 - LOW - Red 1208 1215 1210 1193 1164 1124 1073 1009 935 4 - HIGH - Black 2181 2143 2104 2053 2001 1929 1856 1766 1676 TUD100C960K 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 1908 1621 1888 1609 1868 1597 1834 1582 1800 1567 1745 1533 1690 1498 1631 1438 1572 1377 1 - LOW - Red 1443 1419 1395 1381 1367 1335 1302 1256 1209 TRANS° Performance Data 10 22- 1640-06-0702 (EN) CFM VS. TEMPERATURE RISE MODEL Cubic Feet Per Minute (CM) 500 SPEED TAP 700 '-' 1 0.30 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 BOTTOM AND 1 I 2400 TUD040C924K SEE 4 53 2- N_._OW -Yellow NOTE RETURN 1 - L.OW- Red 1 TUD040C930K 59 49 42 37 33 2356 23991 9 2173 2097 1994 1892 3 - N UGH - Blue 2097 2088 2079 2053 2028 1970 1912 1831 1750 T1A100(972K TUDO60C924K 750 B 56 4 S 1523 1- L Red 1459 1456 1453 1443 1434 1407 1380 1335 1289 4 - HIGH - Bled 2162 2133 TUDO6OC936K 2067 2037 1976 1914 1833 HJ I�l 3 - MFD. -HUGH - Blue 2 - % ED -LOW - T§Ilav 40 1843 34 SI 1776 1572 1746 1670 1538 1483 1593 1428 1619 1606 1 - LOW - Red 1427 1421 14M 1400 1386 TUD080C924K 1327 1285 1243 74 a3 69 54 2036 2005 1923 1840 1750 1659 3 - MED -HIGH - Blue 1906 18814 1856 1817 1777 1724 1671 1692 1533 TUD080C936K 2 - NED. -LOW- Yellow 1646 1632 1617 1596 1575 59 54 1360 48 42 1423 1415 1407 1391 1375 1338 1300 1246 1192 4- HIGH - Black 2462 TUD080C948K 2351 2284 2216 2143 2069 1989 1908 59 54 4 46 4 S 37 35 u 1•UD140C96C4( 2 - MED -LOW - Yellow 1755 1746 1736 1719 1702 TUD080C960K 1609 1564 1518 1- LOW - Red 1450 1446 54 49 46 HI 40 53 31 30 28 27 26 TUD1000936K 67 TUD100C945K 57 49 4 41 7U01000948K 67 62 57 53 49 46 4 41 39 37 TUD100C960K 57 3 41 37 35 32 31 TUD1000972K 57 49 S 41 37 35 34 32 31 TUD120C954K 59 56 47 44 42 40 TUD120C860K 59 56 4 47 44 42 TUD140C960K 69 61 52 49 47 45 FURNACE _....1 [7N /CFM VS. 3M11C PRESSURE (Int w .) MODEL SPEED TAP ° •- 1 '-' 1 0.30 I 0.40 I 0.50 ( 0.60 I 0.70 I 0.80 I 0.90 TUD1000972K 4- H 2484 2458 2432 2387 2342 2275 2208 2125 2041 BOTTOM AND 3 -MED.-HIGH - SEE LEFT SIDE 2- N_._OW -Yellow NOTE RETURN 1 - L.OW- Red 1 4 - H Back 2447 2401 2356 23991 9 2173 2097 1994 1892 3 - N UGH - Blue 2097 2088 2079 2053 2028 1970 1912 1831 1750 T1A100(972K 2- N C7W- v 750 B 1732 1716 1690 1665 1594 1523 1- L Red 1459 1456 1453 1443 1434 1407 1380 1335 1289 4 - HIGH - Bled 2162 2133 2097 2067 2037 1976 1914 1833 1752 T1D12,0(B54K 3 - MFD. -HUGH - Blue 2 - % ED -LOW - T§Ilav 188 1654 1843 1873 1631 1839 5 1776 1572 1746 1670 1538 1483 1593 1428 1619 1606 1 - LOW - Red 1427 1421 14M 1400 1386 1357 1327 1285 1243 4- HIGH -Black 2135 2101 2066 2036 2005 1923 1840 1750 1659 3 - MED -HIGH - Blue 1906 18814 1856 1817 1777 1724 1671 1692 1533 RAl20(96(M( 2 - NED. -LOW- Yellow 1646 1632 1617 1596 1575 1535 1494 1427 1360 1- LOW - Red 1423 1415 1407 1391 1375 1338 1300 1246 1192 4- HIGH - Black 2462 2407 2351 2284 2216 2143 2069 1989 1908 3- MED. -HIGH - Blue 2128 2112 2096 2054 2011 1949 1887 1797 1706 1•UD140C96C4( 2 - MED -LOW - Yellow 1755 1746 1736 1719 1702 1656 1609 1564 1518 1- LOW - Red 1450 1446 1442 1427 1411 1383 1354 12% 1241 22-1840-06-0702 (EN) Performance Data Nob 1: High speed CFM b based on bottom and left side realm option br4is improved albs with the addition of side alum. 11 . Mellon Pigh, Mew Low, and Low speed taps br this nodal do not have TRINE' Field Wiring NOTES I. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATEISI 2. LOW VOLTAGE (24V.) WIRING TO BE NO. 18 A.W.G. MIN. 3. GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 4. SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM. 5. 24V COMMON CONNECTION MAY BE REQUIRED FOR USE WITH ELECTRONIC THERMOSTATS. POWER HUMIDIFIER SAIL SWITCH (OPTIONAL HOOK -UP) HUMIDSTAT TO 115 VOLT POWER SUPPLY ELECTRONIC AIR CLEANER (OPTIONAL) RED OR p ! ;RED L• I I � WHITE ._.._._._._. ' - =HQL•- TO 115 VOLT }POWER SUPPLY LIME VOLTAGE SAIL SWITCH IMPORTED IN RETURN AGO DUEL REQUIRED EM AIR ELGNLAS rx ar urtGRAI AIR SLNSING FEMUR[.( Field Wiring Diagram For Heating Only INTER-COMPONENT WIRING 24 V. 1 FIELD ' -'-'-° LINE V. )WIRING 24 V. FACTORY LINE V. WIRING iwINIYIW {I I I THERMOS AT CONNECTIONS INTEGRATED FURNACE CONTROL HUM N i ! i 1 I i 1 I i HUM X EAC N EAC N OPTIONAL ACCESSORY CONNECTIONS HEATING ONLY THERMOSTAT HEATING ONLY THE MOSTAT TWIT E N SWITCH) S E NOTE 4 SEE NOTE 5 G v LX i ELECTRONIC !AIR CLEANER LN L L I 1 1 i 1 I ! 1 I E ALTERNATE NEURAL CONNEC GAOUX I I 1 SCREW ! ! - -- BLACK r -wxi E j j 1 i I I ii TO 115v., IPH., 60 H2., POWER SUPPLY PER LOCAL CODES POWER HUMIDIFIER r'!Ja LJ (OPTIONAL) f UA XACC� t ! � L � H ,� 1 � � LN JUNCTION — Y — FURNACE BOY From Meg. 218341437 Rev. 1 Field Wiring Diagram For Single Stage Heating/Cooling (Outdoor Section Without Transformer) NOTES I. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATEISI. 2. LOW VOLTAGE 124V.) WIRING TO BE NO. 18 A.W.G, MIN. 3. GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 4. SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM. 5. THE 'T• TERMINAL FROM THE THERMOSTAT MUST BE WIRED TO THE 'Y' TERMINAL OF THE FURNACE CONTROL FOR PROPER BLOWER OPERATION DURING COOLING. 24V COMMON CONNECTION MAY BE REQUIRED FOR USE WITH ELECTRONIC THERMOSTATS. POWER HUMIDIFIER SAIL SWITCH (OPTIONAL 1000 -UP) HUMIDSTAT EJ � TO 115 VOLT L " " " ""1IA(� LH POWER SUPPLY {NEUTRALA 1 LN RED OR I BLACK F^ ELECTRONIC AIR CLEANER (OPTIONAL) LINE VIH(A6( SAIL 511101 IIWNTED 1 RIUAI AIR MKT REOWRED FIN AIR CLEANERS 11Tx0UT iNTIERAL All RINSING ((CURL) L'1 F (WHITE i 11AL.. TO 115 VOLT POWER SUPPLY INTER-COMPONENT WIRING 24 V. 1 FIELD °'•"- LINE V. WIRING 24 V. FACTORY LINE V. WIRING POWER SUPPLY NOTE ib - 2j ,_ -- ! 1 • • THERMOSTAT CON OPTIONAL ACCESSORY CONNECTIONS INTEGRATED I NOTE N 1 HEA THERMOSTAT . r ._._._._._._._� LLA POWER © 1 HUN ID IF IfR 1 P_._�._. LN (OPTIONAL) :if -•L —_ J ! ! I SEE •� i ! r• ^ ^"� l X ! ELECTRONIC I ,/� i AIR CL EAXER " ' CCI LN �(OPTIONAI) ®o©000 SUE 1 1 I 1 1 CONNECTIONS ALTERNATE FURNACE CONTROL CONNECTIONS GL A[X� �Nl if I 1 I i l ! , LW 1 1 LN — V 1 FURNACE TO 16V., IPH . 60 HZ POWER. SUPPLY PER LOCAL CODES L___ - _J LO W VOLT AIR CONDIIIOMIN OUTDOOR SfCTIO WITHOUT TRANSFORMER H 1 FURNACE — JUNCTION BON GROUNI SCREW From Owg. 21 8341436 Rev. 1 12 22-1640-06-0702 (EN) M0013. DM 'A" DM F dM 'C OM 10" 1199040C924 NN •UD040C93Ou •UDO 6CC924•N NU6O60C93644 14 -1/2" 9 -5/8' 13 -1/4' 13' 196080C924 .4 NUD080C936 NN N00088C948NN NUDIO0C9368$ •UDIOOC945NN •UDIO0C9456N 17 -1 /2" 9 -5/8' 16 -1/4' 16' •uD080C960K 1UDIOOC9481N NUD10DC 960•• NOD120C954.* 21' 13 -1 /16' 19 -3/4' 19-1/2' NODIO0C972.* 4116120C960N0 NUD140C960N• 24 -1/2' 15 -5/16' 23-1/4" 23" m 3 5/8 07/8 HOME ELECTRICAL CONNECTION 1 -5/16 14-7/8 1.9/16 3- 15/16 23 3/4 28 1/2 • PREFIX LETTER MAY BE 'A' OR 'T' •• SUFFIX LETTERS MAY BE 'K' I0 THROUGH 91 954 DIAMETER FLUE CONNECT T DM it 951 -1 /2 HOLE — — GAS CONNECTION gggqqq 2 1 /16 — _ — _ - - T 2 -1/8 30 -5/8 28-1/4 22-1/2 I/2 e TUD-C Outline Drawing (All dimensions are In Inches) • 95718 KNOCK OUT ELECTRICAL CONNECTION (ALTERNATE) 2 -1 /I6 32 28-1/4 01-1/2 KNOCK OUT GAS CONNECTION (ALTERNATE) 2 �5 5/16 233/1 14-7/8 1-9/16 1 -5/16 WIIMILMEAMPELICLCOMINISTIELLMATIMALS LPTI OW CLOSET LEFT SIDE 0 IN. FRONT 3 IN. (SEE NOTE IL RIGHT SIDE •0 IN. BACK 0 N. RUE 66 IN. 10P I IN. 11ORI1ONWA1 BIOSET NEE NOTE 21 TOP •2 IN. BACK 3 IN. FLUE 66 N. SIDES I IN. FRONT IN IN. NEE NOTE II NORIZONIAI AIroVt (SEE NOTE 2) 10P 41 IM. BACK 0 IN. FLUE 16 N. SIDES 0 IN. FRONT IB IN. 6 - MAY BE I' WHEN TYPE 0-I VENT IS USED • - FOR 14-1/2' CABINETS 3' WHEN SINGLE WALL VENT PIPE IS USED. WHEN II -1/1" CABINETS (ALL •UD040C NUD040R -, NUD06UC -, AND •UD060R9361 ARE INSTALLED IN A HORIZONTAL POSITION AND A SINGLE WALL VENT PIPE IS USED, A 6 INCH CLEARANCE MUST BE SUPPLIED BETWEEN THE VENT PIPE AND COMBUSTIBLE FLOORING. WOTFS' II MINIMUM CLEARANCE TO FRONT ON NUD14(1961 AND •U0140C960 IS 6 INCHES. 21 MAY BE INSTALLED ON COMBUSTIBLE FLOOR WHEN TYPE 0 -1 VENT IS USED. 3/4 23 -1/2 Fes 3 -13/16 From Dwg.21C341699 Rev. 1 • • a TABLE A SPEED TAPS FOR I.D. FAN MOTOR MODELS MEAT PARK PAN 01004005241 TL RD el •MD0100104 N 4 el IL 1000A0024K BL RD IL •0006003PR YI RD IL •00NTC1244 Ill RD TI N00ROC3GK el RD Yl MRDOBOCRIBK BE RD IL ND0R00601 RD it 0 •UD I OKAN BI RD 0 •UD I OKUA el RD TI 40010004N BL RD IL 40100010K 11 el RD NDIDACRT2G RD IL el •UDI2K551N IL RD II •110120040R SI RD TL •UDIAKSOK BL RD IL III RED - LN 121 YELLOW - MED. LP 01 BLUE - MED. HIGH 111 BLACK . HIGH 22- 1540.05 -0702 (EN) LEGEND-EQUIPMENT DIAGRAM 1 {Jl —LN1 RFACTORI WIRING LIH R. MIME FIELD WIRING - EARTH GROUND 71/4 GROUND • JUNCTION p WIRE MUT N CORRECTOR -1—CNL -N-CAPACITOR TRARSFORMER CO CONNECTOR 0 t TEMP. ACTUATED SNITCH or NESS. ACTUATED SRITCM crl-w DOOR SWITCH +I IMEO Glli FUSIBLE LINN Q IERMNAL TERMYAL BOARD IXN Of TIRE SLACK TINE NUN I BLUE NH[I `CpOe N MARKER SK 'IACS N INANE TI YELLOW IL BLUE ID RED OR GREEN N COIN MI MATTE PR PURPLE 1O GS TAUS IN ND 6i011YT L OP 1 LOBO VOLTAGE TERMINAL BOARD MTN MOTOR I KO NA TCO RIGS TM5 TRANSFORMER IOM TUN[ LIMIT SWITCH eft CDN PS PRES. NITER All NIGH LIMIT INPUT MIO NIGH LIMIT OUTPUT VP FLAME SENSOR PROBE M GAS VISE 11 240 A[ TRANS COMMON SIDE Tl 240 AC RIMS. ROT SIDE A REDUNDANT NI INTERNAL THERMAL PROTECTION UD-C *MA1 BE PREFIX 'A' CO '1' Schematic Diagrams for Gas Furnaces VENT TR. a • • • • U • • U • GND BIM 111/1 RIO Mil FLAME SENSOR ONO Ml A AR AS N /4 REA PA PARK LIME 1K1 H HUN • • • • • • � ND MU Electrical Data ■ 1a; CF ABLE A 9-1(-9 p p Buo 15 ID ITS VOLT 10 R1 NH. POWER SUPPLY PER LOCAL CODES SEE *DIE S COAL ND TIM NON INi IAIESIATFO 1'1■ [MACE tCNTIOL GND DIP PITCH N ® OFF DIP SWITCH SETTINGS COXING FAN OFF DELAY ISECNDSI NI N 0•• NI OFF BO HEATING FAN OFF DELAY ISECON51 F !' • FACTORY SET IMPORRTNT: INTEGRATED FUIRACE COATI% REPLACEMENT MUST it AUTHORIZED O.E.M. PAC RNLI GND cur LNE -A FNGN LIMIT PRESSURE SW. SNITCH • TO CO r-0/1 —Cr IL r Il /2 A RNNSE FLOE HITCH TEDN 5 AMP I 5 1 FUSE :. 000 0 1-' SEE NOTES 2 AND 3 AOIIOUI SWITCAES OII ■/I MANE' GAS VALVE NOTES: I. IS ANT OF TIE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MST BE REPLACED. IT MUST Of REPLACED WITH WI11NG MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST OS 'C. 2. THERMOSTAT MEAT ANTICIPATOR SETIIN: .34 AMPS. 5. FM IRNEI KERATIN OF COOLIIIO FAN SPEED. - 1' TERMINAL MST BE CONNECTED TO DOOM THERMOSTAT. 4. THESE TERMINALS PROVIDE 1200 PORN FOR CORRECTION OF ELECTRONIC AIR CLEANER AND ANIDIPIEM. MAT. LOAD 1.0 AMPS EACH. S. EDEN TRIMMING TWO FURNACES. BOLA UNITS N51 BE CORRECTED TO TAE SAME I 15MAC PHASE. CONNECT THE TWO TI E. D 'TWIN' TERMINALS RITA CL 10 T2TRE. WOU. From ()wig. 21D341704 Rev. 1 06 -09 -2006 PHILLIPE CROZIER 1510251AVS TUKWILA WA 98188 RE: Permit No. M06 -003 15102 51 AV S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be In writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/05/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely rshall, Permit Technician xc: Permit File No. M06-003 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431.3670 • Fax: 206 - 431 -3665 License Information License PERFOHA150RT Licensee Name PERFORMANCE HEATING & A/C INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600601386 Ind. Ins. Account Id 49459900 Business Type CORPORATION Address 1 7649 S 180TH Address 2 City KENT County KING State WA Zip 98032 Phone 4252510356 Status ACTIVE Specialty I GENERAL Specialty 2 UNUSED Effective Date 12/30/1985 Expiration Date 4/29/2007 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date GOWIN, RICHARD L 01/01/1980 GOWIN, CONSTANCE F 01/01/1980 Look Up a Contractor, Electririan or Plumber License Detail Page 1 of 3 lam+ Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond 49 Bond Company Name DEVELOPERS SURETY & INDEM CO Bond Account Number 853803C Effective Date 04/28/2002 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount $12,000.00 Received Date 04/23/2002 https: / /fortress wa gov /lni/bbip /printer.aspx ?License= PERFOHA15ORT 01/06/2006