Loading...
HomeMy WebLinkAboutPermit M06-005 - KING COUNTY METRO - SOUTH BASEMETRO SOUTH BASE 12100 EAST MARGINAL WAY S M06 -005 Parcel No.: Address: Suite No: Tenant: Name: Address: City & Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us 7340600421 12100 EAST MARGINAL WY S TUKW METRO SOUTH BASE 12100 EAST MARGINAL WY 5, TUKWILA WA Owner: Name: KING COUNTY Address: 500 K C ADMIN BLDG, SEATTLE WA MECHANICAL PERMIT Contact Person: Name: GERRIE JACKSON Address: 201 5 JACKSON ST KSC -TR -0431, SEATTLE WA Contractor: Name: DESIGN AIR, LTD. Address: 8657 SOUTH 190TH ST, KENT, WA Contractor License No: DESIGL *212DG Value of Mechanical: $51,000.00 Type of Fire Protection: Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 2 Ventilation System 2 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 doc: IMC -Permit * *continued on next page ** Permit Number: Issue Date: Permit Expires On: EQUIPMENT TYPE AND QUANTITY MO6 -005 04/18/2006 10/15/2006 Phone: Phone: 206 684 -1334 Phone: (253) 854-2770 Expiration Date:03 /07/2008 DESCRIPTION OF WORK: CUT TWO NEW ROOF PENETRATIOSN OVER PAINT BOOTH AND DUST COLLECTOR. INSTALL NEW EXHAUST FANS ON ROOF. INSTALL NECESSARY DUCTING AND ELECTRICAL POWER TO FANS. Fees Collected: $557.61 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 3 -15 HP /500,000 BTU 15 -30 HP /1,000,000 BTU.. 30-50 HP /1,750,000 BTU.. 50+ HP /1,750,000 BTU Fire Damper Diffuser Thermostat Wood /Gas Stove Water Heater Emergency Generator Other Mechanical Equipment Steven M. Mullet, Mayor Steve Lancaster, Director M06 -005 Printed: 04 -16 -2006 Permit Center Authorized Signature: Print Name: doc: IMC- Permit City Or' Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: cttukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -005 Issue Date: 04/18/2006 Permit Expires On: 10/15/2006 Date: 011/4/1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction - the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: • C / I /—_ Date: y / /sd �P This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M06 -005 Printed: 04 -18 -2006 tukwila City of Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 7340600421 Permit Number: M06-OO5 Address: 12100 EAST MARGINAL WY S TUKW Status: ISSUED Suite No: Applied Date: 01/18/2006 Tenant: METRO SOUTH BASE Issue Date: 04/18/2006 1: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS 2: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 3: An approved automatic fire sprinkler extinguishing system Is required for this project. (City Ordinance #2050) Extend sprinkler protection to spray booth duct. 4: Extend sprinkler protection to dust collector duct unless the largest cross- sectional diameter of the duct is less than 10 inches per 2003 International Mechanical Code section 510.7. 5: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to Installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 6: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 7: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 8: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Conditions M06 -005 Printed: 04 -18 -2006 City of Tukwila Print Name: afl'& Jstc rYo pJ Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 - 3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: y - o doc: Conditions M06-005 Printed: 04 -18 -2006 Nier CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Site Address: 12In0 Fast Ma Way q Tenant Name: Metro South Base Property Owners Name: King County Metro Building Permit No. �f Mechanical Permit No. Mai -'I � C� Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print** SITE LOCATION King Co Assessor's Tax No.: 7340600421 Suite Number: Floor: New Tenant: ❑ Yes ®..No Mailing Address: 201 S. Jackson St KSC -TR -0431 Seattle, WA 98104 State CONTACT PERSON Name: Gerrie Jackson Day Telephone: ( 206) 684 -1334 Zip Mailing Address: 201 S Jackson St. KSC-TR -0431 Seattle, WA 98104 City State Zip E - Mail Address: gerrie.jackson @metrokc.gov Fax Number: ( 684 -1900 GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page) Company Name: to be bid Mailing Address: state Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: State Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: ENGINEER OF RECORD - AMI plans must be wet stamped by Engineer of Record Company Name: Mailing Address: State City Contact Person: Day Telephone: E -Mail Address: Fax Number: q:Openniis plebs dunaetpennit application (7-2004) Revised 6-8-05 b6 Page I Unit Type: Qty Unit Type: Qty Unit Type: OW Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU. Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 2 Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Command Other Mechanical Equipment MECHANICAL PERMIT INFORMATION — 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: to he hi Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ 51, 0 0 0 Scope of Work (please provide detailed information): Cut two new roof penetrations over paint booth and dust collector. Install new exhaust fans on roof. Install necessary ducting and electrical power to fans. Viz. Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... ❑ Fuel Tvne: Electric ❑ Gas .... ❑ Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CER AT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PE BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: GPrrie darken'''. Mailing Address: KS C— TR— 0 4 3 1 2 01 S. Jackson St. Seattle WA 98104 city State BUILDING 0 AUTHORIZED j r Signature- C Lc Date Application Expires: I Date Application Accepted: 01/0 11 q: \`penniu pluc\icc clunrcc'pennil .pplicuion (7 -2 4) Revucd 6-8-0S bb Page 4 Date: VI 3 / n to Day Telephone:(206) 6 84 - 1334 Staff Initials: Zip Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: TRANSACTION LIST: Type Method Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 7340600421 12100 EAST MARGINAL WY S TUKW METRO SOUTH BASE R06 -00519 LAW 1630 KING COUNTY Payment Check 4403 RECEIPT ACCOUNT ITEM LIST: Description Account Code MECHANICAL - NONRES 000/322.100 Permit Number: Status: Applied Date: Issue Date: Payment Amount: 452.09 Payment Date: 04/18/2006 08:32 AM Balance: $0.00 Amount 452.09 Current Pmts 452.09 Total: 452.09 M06 -005 APPROVED 01/18/2006 4665 04/18 9716 TOTAL 452.09 Punted: 04 -18 -2006 Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: doc: Receipt City of Tukwila TRANSACTION LIST: Type Method 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 7340600421 12100 EAST MARGINAL WY S TUKW METRO SOUTH BASE R06 -00065 3EM 1165 KING COUNTY Payment Check Description 4387 RECEIPT ACCOUNT ITEM LIST: Description Account Code PLAN CHECK - NONRES 000/345.830 Permit Number: Status: Applied Date: Issue Date: Payment Amount: 105.52 Payment Date: 01/18/2006 02:14 PM Balance: $452.09 Amount 105.52 Current Pmts 105.52 Total: 105.52 M06 -005 PENDING 01/18/2006 1375 01/18 9716 TOTAL 105.52 Printed: 01- 18-2006 Projectp: ��//e� ,// /J Wl $ c/44p s T Type of I�ection: /� / �•Gf l i Address: - pate Called: Special n tructions: /O ((VVVV// Requester� Wanted: �.m —7 /O-3 �/ � Phone 74 -.Z 7 e2 t i—, Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 s PERMIT NO. g (206)431 -3670 Corrections required prior to approval. COMMENTS: /90 e1-1,711Mi S58.60R INSPECTION REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cali the schedule reinspection. 'Receipt No.: 'Date: Project: » /rd -SA/ /A (i,Se- Type of Inspection: V /2d>/5 h -in. Address: / 2 / OU - Pas# /tl1>,),n / Date Called: J.. Special Instructions: Date � ,C/— /o (P.m. Requester: Phone No a 0,6 -sy7 - 075 - L 'Palk i ❑ Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 /n0 -60 IT P 0. (206)431 - 3 7 Corrections required prior to approval. COMMENTS: / �T7t/1 CZ/ri iV>, ✓/ t / #/@ /7:1 r S . /L .n j � / // d�, / / } <Lh ( S / "of / a r An S/d/ /// /is79 Gt-7 If o i 74 (j4 Inspector: Date g ri ❑ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspectlon. Receipt No.: 'Date: 1s.A !,- #:.l.. n' Y {• . COMMENTS: 4 1-I c �?r,3-, i yrP!-� v•;. .�ro -14 ,C.,,,, fl iN. gr.. s in / o e." y____ ,0%;1c .b ev6--7-> 4 - Special nstructions: 7 .cv// /5 n,4 ����/ 1 /�' kett"' / 267/' �� a CA. / L: 322 /%0 n7c-o/ /t�r -ttn/,r.t 19 r , & 1,2_ 4--..- /,,c:-.,.L. / L .7i) land-4 El // S e CP- Len' et. A 71 Col 44,1-6, J < < n S :7 fl,�4.o � _ . ' n-' y / Li.,nc,/ zie// '.n At .l / / R - .07-no L ie n s e/ I 7 �.✓� / iI f rle0lC 1—n �s .4-7m056.9.4,„ a#s.,■ dl� , l� G>, X 4 /IA Jim f7A A,O / %A.I Project: n- Ale77m 42 /jy Type of Inspection�: 7CPt/ . �a'�� i� , / /. Address: 1 ?tie F //�eV Date Called: Special nstructions: 7 .cv// /5 n,4 ����/ 1 /�' kett"' / 267/' �� a CA. / L: 322 /%0 n7c-o/ Date Wanted: m' /,7 / /-tx P,m Requester: ._ T f'4/✓ Phone No: 2/,Y ^9'97 - 0754 INSPECTIO NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Inspector: INSPECTION RECORD Retain a copy with permit 6)431 -3 (2 Corrections required prior to approval. Date: ri ❑ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: (Date: Project: K A /I (A: AA n2o Hood & Duct: Monitor: Type of Inspection: SPR lMK JRR e CaAi. Address: a wt.) Suite #: L . 10A-72-& 1I`1 5. Contact Person: .rcRit -t VJ% tLtA NA5 Special Instructions: Phone No.: (7a0) -03sCo Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT MOB -CnS PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 COMMENTS: } c RNA VJOT 0V &iN1L -- L V. PrOu ZLt g`t Copt Inspector: (f w J s i Z/ PM / S 1 Date: ►of l� )n(,, Firs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from N / /k th) City of Tukwila Finance Department. Call to schedule a reinspection. <- 0 per applicable codes. n Corrections required prior to approval. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 File: M06- 0005 35mm Drawing #1 -14- 08 -30 -2007 GERRIE JACKSON 201 S JACKSON ST KSC -TR -0431 SEATTLE WA 98104 RE: Permit No. M06 -005 12100 EAST MARGINAL WY S TUKW Dear Permit Holder: City of Tukwila la Steven Al. Mullet, Mayor Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206-431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be to wri ting and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 10/07/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, r Wk' fer Marshall, Permit Technician xc: Permit File No. M06-005 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206 - 431 -3665 03-01 -2007 GERRIE JACKSON 201 S JACKSON ST KSC -TR -0431 SEATTLE WA 98104 RE: Permit No. M06 -005 12100 EAST MARGINAL WY S TUKW Dear Permit Holder: City of Tukwila Steven Al. Mullet, Mayor Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writinx and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 04/10/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ll, Permit Technician ikom xc: Permit File No. M06-005 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 09 -05 -2006 GERRIE JACKSON 201 S JACKSON ST KSC -TR -0431 SEATTLE WA 98104 RE: Permit No. M06 -005 12100 EAST MARGINAL WY S TUKW Dear Permit Holder: Thank you for your cooperation in this matter. Sincerely, XC: Permit File No. M06 -005 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director In reviewing out current records •the above noted permit has not received a final inspection by the City. of Tukwila Building Division. • Penile International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit; or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City of Tukwila Inspection. Request Line at 206431 -2451 to schedule for the next or final inspection. • This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the, Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be In writine and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 10/15/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206- 431 -3665 ACTIVITY NUMBER: M06 -005 DATE: 01 -18 -06 PROJECT NAME: METRO SOUTH BASE SITE ADDRESS: 12100 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bui ing Division _ Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [7 Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS ROUT NG: Please Route Structural Review Required ❑ No further Review Required Li REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2-28-02 QERMIT COORD copy PLAN REVIEW /ROUTING SLIP Structural Approved with Conditions 51( 4W9 lad Fire Prevention DATE: DATE: Planning Division ❑ Permit Coordinator ❑ DUE DATE: 01 -19-06 Not Applicable ❑ DUE DATE: 02-16-06 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License DESIG12212DG Licensee Name DESIGN AIR LTD Licensee Type CONSTRUCTION CONTRACTOR UBI 600314241 Verify Workers Comp Premium Status Ind. Ins. Account Id Business Type CORPORATION Address 1 8657 SOUTH 190TH ST Address 2 City KENT County KING State WA Zip 98031 Phone 2538542770 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/7/1979 Expiration Date 3/7/2008 Suspend Date Separation Date Parent Company Previous License Next License MRCCOL'981JB Associated License Look Up a Contractor, Electrician or Plumber License Detail Search Topic Index t Contact Info Page 1 of 4 Home f Safety Claims $ Insurance Workplace Rights Wades a Licensing 1 Find a Law or Rule Get a Form or Publication Look Up a Contractor, Electrician or Plumber Printer Friendly Version [General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment lof account and carry general liability insurance. 1 https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= DESIGL *212DG 04/18/2006 DES MOINE AUBURN / ALGONA VICINITY MAP NOT TO SCALE BELLEVUE •.. PROJECT SITE • r•� WAN I' it 1 LAKE WASHINGTON ' IEIVU m .,n X111 �.i a i wi .�.m i_ ntit: 11/ uIIIuI Iii_ L _ , o � � '��i� ll �~ ..�Yl.e �....I.III �..„ SHEET NO. DWG NO. LOCATION MAP • SEPARATE PERM ; • REQUIRED FOR: Cl Mechanical N Electrical • O Plumbing 0 Gas Pip?rig City Of.Tuk ; G BUILDING DIVISION B HAMBUN - B. ISLER AS SHOWN TYPICAL SECTION AND DETAIL REFERENCING SYSTEM (1) THE SECTION IS ON DRAWING A1.01: SECTION LETTER ELEVATION LETTER .� Lsi 0 C5.0, A/S1.01 DRAWING ON WHICH SECTION /ELEVATION APPEARS. (2) ON DRAWING A105 THIS SECTION IS IDENTIFIED: SECTION LETTER SECTION - DRAWING ON WHICH SECTION SCALE: 1'a1' -0" • C1.Olr WAS TAKEN. (3) DETAILS ARE CROSS - REFERENCED IN A SIMILAR MANNER, • EXCEPT THAT DETAILS ARE IDENTIFIED BY NUMBERS RATHER THAN BY LETTERS. • REVISION CODE COMPLIANCE aoconuFO JAN 3 0 2006 of �Ufi�� NP l• TON GENERAL 1. G0.01 2. .. G0.02 ARCHITECTURAL 3. A1.01 4. A5.01 5. A5.02 MECHANICAL 6. M1.01 7. M1.02 • 8. M3.01 •9. M3.02 10. M5.01 11. M6.01 ELECTRICAL 12. • E1.01 13. E2.01 14. E6.01 INDEX TO DRAWINGS VICINfY MAP, 'SiTE PLAN AND DRAWING INDEX ABBREVIATIONS PARTIAL ROOF PLAN DETAILS DETAILS PARTIAL ROOF & 1ST FLOOR DEMO PLANS PARTIAL ROOF & FIRST FLOOR PLANS SECTIONS SECTIONS PARTIAL PLAN & SECTIONS 'MECHANICAL EQUIPMENT SCHEDULE ELECTRICAL PLAN, DIAGRAM & SECTION EXISTING ELECTRICAL ELEVATIONS • PANEL SCHEDULE cit e! c i stud! be made to the smpe c : :tottt prior approval a' i .. "- s :a E3e2;:dinj Division. 1:.`.i71: •r .: J ::or:a will require a new plan su )mittai .an:i r- :ude additional plan review t S. •ua CON it N0. - - t t+e Iew approval Is subject to emrs and omIssItaKEND ApOlilt of construction dots does not the Nation of any accepted code or ordinance. of *proved Field Co and conditions is aduwwledga poet loran t+h/ OW of � BUILDING DIVISION : J TURNER REOOWDgFD: D. CRIPPEN IBI NO 432691 sopa Imo. 047 -32 CONTRACT NO: C45153C I IiIl11I IIIj111 1111'11 I I11111111I11111I11ilIIII 1l.!.Il� Inch 1/16 ;2 3.. 4 5 6 4. . • 9• a bII• l- L L. 0 b , � �..,w`.,...., I y'"�`L`yi 6 w .11 1111111111111111 I .LIII III.III.11. 1111. UIIIIILI .IIIIIIIIIi 111111 111.I I. IiIJIII11111J 111 p IIIIIIJI1I .II11_I1111I 1I SOUTH BASE 1161WENNICE BUILDINQ OPERATIONS BUILDING CONTRACTOR'S ENTRANCE FUEL & WASH BUILDING ONE INCH AT FULL SIZE 5. 12N! ST. AREA OF WOW F NOT ONE INCH, SCALE ACCORDINGLY SIN LOCATION N0: King County Department of 7Yaneportation srr8 PLAN - U 20Q . .co • u u RECEIVED CITY OF TUKWILA JAN 1 8 akd • PERMIT CENTER SOUTH BASE • ST COLLECTION SYSTEM UPGRADE CONTRACT NO C45153C A METRO TRANSIT DIVISION SOUTH BASE MAINTENANCE BUILDING DUST COLLECTION SYSTEM UPGRADE VICINITY MAP, SITE PLAN AND DRAWING INDEX OCT 2005 OMYI* G NO: G0.01 SHIT NO: OF 1 14 V I I I LI ri1.1" I �� � ry l Inch 1116 1 91. JIILI 46 IIIIIIILIif tIIlIiILIIiIIi•IIILILIIIIIILIII i ABBREVIATIONS (ALL MAY NOT APPLY) AFF AFC AFS ATF BLDG CA CB CONC CFM CW DET DIA DFS DFR ON DWG DI DIP EFF : EC EL EO ESP F FLEX FD FLR FF GAL GA GALV GE HT HP HZ IN IE IW KW LBS • LO. MH ,MAX No. • REVISION ABOVE FINISHED FLOOR ANTIFREEZE. CONCENTRATE ANTIFREEZE SUPPLY AUTOMATIC TRANSMISSION FLUID BUILDING • • COMPRESSED AIR • CATCH BASIN CONCRETE CUBIC FEET PER MINUTE COLD WATER DETAIL DIAMETER DIESEL FUEL SUPPLY DIESEL FUEL RETURN DOWN • DRAWING DUCTILE IRON DUCTILE IRON PIPE EFFICIENCY ELECTRICAL CONDUIT ELEVATION ENGINE OIL EXTERNAL STATIC PRESSURE FIRE MAIN 'FLEXIBLE FLOOR DRAIN FILTER, LUBRICATOR AND REGULATOR FINISH FLOOR GALLON GAUGE GALVANIZED GROUND ELEVATION HEIGHT HORSEPOWER HERTZ INCH INVERT ELEVATION INDUSTRIAL WASTE KILOWATT POUNDS LUBE OIL MANHOLE MAXIMUM BY APP'D DATE MBH 1000 BRITISH THERMAL UNITS /HR MIN MINIMUM OC ON CENTER OD , OUTSIDE DIAMETER OFD OVERFLOW DRAIN . • PH PHASE POC POINT OF CONNECTION PRV • PRESSURE REGULATOR VALVE RD • ROOF DRAIN REINF REINFORCED SS STAINLESS STEEL SC SOAP CONCENTRATE . SCH SCHEDULE . SL SLOPE SP STATIC PRESSURE SCFM STANDARD CUBIC FEET PER MINUTE STM STEAM SD STORM DRAIN TK • TANK TYP TYPICAL UGE UNDERGROUND ELECTRICAL V VOLTS WC WATER COLUMN WF WASHER FLUID WNP WATER, NON— POTABLC WP WATER, POTABLE W/ WITH • YD YARD DRAIN lamp II / DESC EII•. R NICHOLS DRAM7C , B HAMBUN CHECKED J TURNER RECONUOIDEDe D. CRIPPEN PROJECT YAINCER K MADDEN APPROVEDe B. ISLER SCALD AS SHOWN ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LODVION NO: !6 Noe 432691 ow icawe 04T-32 CONTRACT NO: • C45153C King County Department of Transportation REVIEWED FOR CODE COMPLIANCE toon! "I ) • . JAN 3 0 2006 atyOfTukwila BUTLOT I nik'TSTON • CITY OF TUKWIL.A • JAN 18 200.6 PERMIT CENTER METRO TRANSIT DIVISION SOUTH BASE MAINTENANCE BUILDING •DUST COLLECTION SYSTEM UPGRADE • ABBREVIATIONS DOE: OCT 2005 G0.02 SNEET 110: Or 2 14 ti ...111 11 *I711I I 11 5I 1 ` I ` I I IL �I I � I I I � I I JII 111J.1I I I LIL! I.1I11.1111 1111 (10 110 0 L NEW PAINT BOOTH � EXHAUST FAN EF -1I `1 A A A No. REVISION O BY AP DATE NEW DUST COLLECTO EXHAUST FAN EF -2 V 1 NEW EXHAUST STACK ► f° ► Y FOR DETAIL IN THIS AREA SEE DWGS M111 & M1.02 PARTIAL ROOF PLAN SCALE: 1/B " =1' -0" V O • 314 REGISTERED' IOUS, !WC Cf rw TEN DCDCNEEt R NICHOLS • DRANK B HAMBUN coconlk Y FARJO RECONAInJOm D CRIPPEN PROJECT NAPPOCt K MADDEN CONTRACT NO C45153C KEY PLAN SCALE: . AS NOTED N'FROYEDI ONE INCH AT . FULL SIZE B ISLER Las NO h- -I 432691 IF NOT ONE INCH. vas Karns o4T SCALE ACCORDINGLY S TE LOCATION I King County Department of Transportation CREVIEWED-FOR E O E COMPLIANCE .f! oemn�►cgy JAN 3 0 2006' City Of Tukwila I3UTI_f TIW nT' TOIV METRO TRANSIT DIVISION SOUTH BASE MAINTENANCE BUILDING DUST COLLECTION SYSTEM UPGRADE PARTIAL . • .ROOF PLAN CITY OF RECEIVED JAN 1 8 2006 PERMIT CENTER DATE: OCT 2005 DRAVIINO SHEET NR Or 3 14 I I II I . . l . l . l . . I . I . I I I il, I I, Inch 1116. .. 1I s� I • et at . I111111IIIII1.Iliiiji i1I111 IIIII11I1111 ill l`Ii.011 '. . I. WO 1.(11!1 111 11.1iI 1 1111111l1111.1111ll1.11 ►IILI�II IliU I, l llllllil�llll ►.. . Inr IMI III FOR CURBING DETAIL SEE COLD MASTIC FINISH BELOW WOOD (TYP) WOOD CANT WOOD NAILERS STAINLESS STEEL BOLTS,1 /2 "0 X 4" LG. NUTS AND WASHERS SET MECH EQUIPMENT ON NEOPRENE GASKET ROOFING MATERIAL FASTENER PRESSURE TREATED CURBS 8" MIN. ABOVE TGP OF ROOF COLD MASTIC FINISH UNDER WOOD (TYP) • REFER TO DWG. E1.01 • FOR DISCONNECT DETAILS 3 "0 GALV. SCH. 40 PIPE FASTEN 2X6 DOWN TO CONCRETE WITH . 1/2 X 5 -1/2" LG. STAINLESS STEEL BOLTS /NUTS/WASHERS (2 PER SIDE) STANTION SUPPORT DETAIL SCALE: 3 " =1' -0" STAINLESS STEEL GASKFTED FASTENERS 0 16" O.C. • MIN TWO FASTENERS PER 'SIDE ROOFING CALLOUTS INTEGRAL FLASHING LIP OF MECH EQUIP TWO PART COUNTERFLASING REGLET HPR MODIFIED MEMBRANE BASE FLASHING 12" MIN. HT SHEETING BOND • SEE DETAIL "2" FOR ROOFING CALLOUTS • 1' —O" 1r • EXIST ROOF SYSTEM CONCRETE DECK STANDARD CURB DETAIL • ( SCALE: 3 "= i' -0" M1.02 M5.01 A5.02 M3.02 (11 SEALANT ALL AROUND 1" x 16 GA 5S CLAMP WITH SS BOLT NUT AND WASHER ALUMINUM STORM COLLAR FLASHING LAP AND SEAL 0 JOINT • ALUMINUM DUCT FLASHING LAP •1" RIVET AND SEAL STAINLESS STEEL GASKETED FASTENERS 0 16" 0.C. MIN TWO FASTENERS PER SIDE SEE DET • "2 FOR CALLOUTS 1' -0" 8" MIN. ABOVE TOP OF ROOFING (EXIST) E1.01 • M1.02 'CONDUIT OR PIPE THRU ROOF SIZES LESS THAN 4" 1 "x 16 GA' SS CLAMP W/ SS BOLT NUT AND WASHER 4 LB LEAD FLASH'G COLLAR SET IN ROOF CEMENT COLD APPUED "BURMASTIC" 3 PLY ROOF SYSTEM TO MATCH EXIST PIPE SUPPORT ROOF CURB HEIGHT 12" MIN. 8" CONCRETE ROOF DECKING MIN: SEALANT 6" NEW PREP AND LAP OOFING 1/2" CUT HOLE 1 "LARGER CONDUIT THAN PIPE (5" MAX) WATERTIGHT SHEET METAL RAIN COLLAR OVERLAPPING FLASHING COLLAR BY 3 -4 INCHES • PENETRATION • • OVER EXIST • ROOF CEMENT OR SEALANT DETAIL SCALE: 3"=V-0" E1.01 ROOFING (EXIST) NEW VAPOR RETARDER CONC• DECKING (EXIST) 6" 2' -0" REMOVE EMBEDDED GRANULES /DEBRIS & PRIME • CAST NEW GRANULES 1' -6" OVERLAP AND PRIME EXIST ROOF MEMBRANE FEATHER GRANULATED COVER SHEET 5 COURSE REINFORCEMENTP) GARLAND LYY OOF SYSTEM NEW MATCH EXIST ROOFING • I REMOVE EXIST HVAC EQUIP AND CURB . OR NEW CURBING INSTALLATION L.� EXIST ROOF PENETRATION TO BE FILLED ROOFING • (EXIST) ' • 3 PLY BURMASTIC —POLY ISO INSULATION TYPE • N VAPOR RETARDER CONC DECKING (EXIST) EXIST ROOF EXIST ROOFING EXISTING ROOFING /INSULATION FEATHER GRANULATED COVER SHEET WITH 5 COURSE REINF.(TYP) SHEET METAL COLLAR SEAL TIGHT SHEET METAL FLASHING RECEIVER 12 AND 18 PLY SH ETS ADHERED IN SPEC D MASTIC EXIST FRAMING VERIFY TYPICAL ROOF PATCH • DETAIL SCALE: 3 " =1' —O" • VAR VAPOR RETARDER TO OVERLAP EXIST VAPOR RETARDER C ONCRETE ROOF DECKING Ti EilST BE • • • Ten ' . i >t EW � COMPL IAN C aaa' I : ij JAN 3 0 2006 City (*Tukwila SHEET METAL EIJp O6UFtE qT+ J' V TIBET REMOVJIBLE TOP — OAK OR SLOPE FOR DRAINAGE INSULATE ALL OF E UOSURE SIDES AND TOP TO PREVENT CONDENSATION I SLOPE DUCTING DOWN AWAY FROM ENCLOSURE SEE ROOF DECK CITY OF TUKWILA SECTION n JAN 1 8 2008 SCALE:. NONE • M1.02 M5•01 PERMIT CENTER A A A A A A No. . REVISION APP'D DATE N N.' REGISTERED' SWEE O wAssems DES CRER R NICHOLS DRAM/C B HMABUN CMCKEIR Y FARJO RECOAM EMCIR D CRIPPEN PROJECT MANAGER: K MADDEN APPROVER B ISLER 1313 RCA 432691 "aNM IMMKin 04T - COmRACT Noc C45153C SCALE: • AS NOTED ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SRE LocAnOR NO: King County Department of Transportation METRO TRANSIT DIVISION SOUTH BASE MAINTENANCE BUILDING DUST COLLECTION SYSTEM UPGRADE DETAILS • DMZ: OCT 2005 ORONO NR A5.01 SIMIT NQ CI 4 14 l l•IIIIII IIIIIIII IIII III � I I I ..3 Inch 1/16 1 i% .111 .1 91• 46 £4 ,� Z6 II 0I' 0 8M- 1. _ IIIIIIIIIJII�IIILIIIII�IIii ►IIIIIIIIILIlliIIIULII I JIIIIIIIIIIIIIIIiIIIIII !IJIIIIIIIiI111J i '111 I 11 I I l I�1I III, I'I1 i�I Ii 4I � I 5I I I 6 • JilIIIIII . IAVIV.I•IIIIIIIILIII!IijJUII ii�IIIIIIIII.IIIII A A A A SEE NOTE 1. �. ❖.• eeeeee � .e❖.•.00•.O❖.❖.❖.❖..; . 3/16 SEE NOTE 1> 3/16 V • 1" X 16 GA SS CLAMP /SS BOLT NUT AND. WASHER SEE NOTE 1 > 3/16 V NEW INSULATION IN MASTIC MATCH EXISTING WIRE CABLE (3/16" *VINYL JACKETED GALVANIZED CABLE SPOOL) CUP & THIMBLE KR (3/16" CLAMPS AND. 1 THIMBLE (TYP) TURNBUCKLE (EYE TO EYE, HOT DIPPED. GALVANIZED, 500 POUND LOAD, 1/4" THREADED DIAMETER) CLIP & THIMBLE KIT (3/16" CLAMPS AND 1 THIMBLE) 4" -- REVISION 12" EXIST. CONC. 1 1/2" • 6" BY ROOF DECK NOTE: MAX LOAD IS 300 lb AT 45' ANGLE. GUY WIRE ANCHOR DETAIL . SCALE: NONE M1.02 M5.01 APP'D 1 1/2" DATE 6" FORGED STEEL EYEBOLT W/ SHOULDER 3'4" DIA. SHANK—.THREAD INTO TOP PLATE & WELD IN PLACE STEEL PIPE (3 "0 SCH. 40 GALVANIZED) STORM COLLAR URETHANE "TUI•t51UFF" SEALANT CLAMP LEAD FLASHING FLASHING BOND URETHANE SEALANT / 2 PLY STRIPPING FELTS' 1. HBR TRIBASE 2. STRESS PLY "E" MINERAL (TOP) 4 2 PLY TRIBASE SEE NOTE 2 EXIST. TRIBASE (TOP) EAST. POLYISO INSULATION )Tt "x13 "x12" STAINLESS STEEL PLATE BOLTS, NUTS AND WASHERS 1 1/2 "0 X 4" LG. STAINLESS STEEL • I II 1 1 1 11 iIi1'i IIIIIIILIII1II LI Inch 1/16 l l I •,::�►� EXIST. VAPOR RETARDER 91. b £I. ZL I - .IIIIIIIIIIIl _Ii1tIIIIIIIIIIliiIllllllIi.ILI SEE NOTE 1 atw REGISTERED ARCHRECT TOM MO STATE OF.WA9WIOION I ; 1.1:p; III I(III1 FOR CURBING DETAIL SEE • A5.01 2' -4" x 2' -4' x 1/2; ALUM PL -3003 ALLOY WI (8) 1/2 "0 316 STAINLESS BOLTS WI WASHERS & NUTS. (3 PER SIDE) COLD MASTIC FINISH BETWEEN ALUM. PLATE & CONC. DECK 1/8" THICK BOTTOM CLOSURE PLATE .SLOPE TO DRAIN • R NICHOLS K MADDEN DRAWIR APPROVER NOTES: DkSICIER PROJECT LUNAG'ER B HMIBUN B ISLER C EOaR BS NR 432691 Y FARGO Aas lams ENT-32 RECOMMENDED: CONTRACT NR D CRIPPEN C45153C I a I. wo 1 LII�IlW. 11.Ia�llilll�J��Ilii iti11 l{1,111.I1I1tii iii��L 1111LI�1a lill lIlii I ► 1/16 DISCHARGE DUCT MOUNTING DETAIL • SCALE: 3"0' -0" 1y 111, 111111111111111 SCALE: AS NOTED ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SRC LOCATION NR M5.01 M1.02' SEAL WELD 1. BRUSH, WELD, CLEAN, PRIME AND PAINT. ' 2. HEIGHT AROUND GUY WIRE ANCHOR SHALL BE HIGHER THEN EXISTING ROOFING SYSTEM. • King County Department of 7ransportaUon 2 1/2" (TYP) STAINLESS STEEL BOLT, NUT AND WASHER 1/2 "0 X 4" LONG. CODE ED FOR M P 1 IAIVCE Qnon1114 • • JAN 3 0 2008 ' Cit Of T ukwila DISCHARGE DUCT SEE NOTE 1 1'0 DRAIN HOLE SEALANT Au. AROUND 1' X 16 GA SS CLAMP WITH SS BOLT NUT AND WASHER ALUMINUM STORM COLLAR •FLASHING LAP AND SEAL 0 JOINT ALUUIN111' DUCT FLASHING LAP 1" RIVET AND SEAL 3" WIDE X 3/16" TH. ALUM COLLAR — 3003 ALLOY 1/ (� 4 "• STAN. STEEL. METRO TRANSIT DIVISION SOUTH BASE MAINTENANCE BUILDING DUST COLLECTION SYSTEM UPGRADE DETAILS RECEIVED CITY OF TUKWILA JAN 18 2005 PERMIT CENTER CAIE: OCT 2005 ORAWNO 8' MIN. NOT A5.02 STET NR OF 5 14 M3.01 BRIDGE CRANE 4 _ .11 AHU -107 LT DUST COLLECTION j DUCT ROOF I f ' PENETRATION . PAINT BOOTH . FAN SUPPORT CURBING LOCATION L —I .r r� A A A A No REVISION PARTIAL ROOF PLAN ' SCALE: 1 /4 " -1' -0" BY APP'D DATE FAN SUPPORT CURBING LOCATION I r 1 • __J J. LOCATIONS OF NEW ROOF MODIFICATIONS REMOVE DUCTING AND CURBING INSTALL 16 GAUGE SHEET METAL COVER OVER OPENING IN ROOF WITH (4) CONCRETE FASTENERS (HrLTI 1/4" X 3" LG. QUICK BOLT) AT EACH CORNER. FINISH ROOFING PER DETAIL rTh .. A5.01 REMOVE THE DUCTING FROM THE PAINT BOOTH AND THE DUST COLLECTOR DISCHARGE TO THE ROOF. REMOVE ALL SUPPORTS AND ATTACHMENTS. • -SHOP 27 Icon it/e/ DESIGNED: R NICHOLS DRADIR B HAMBLIN CHECKED: J TURNER RECOHIENOED: 0 CRIPPEN PROJECT TNNAOER: K MADDEN APPROVme B ISLER PARTIAL FLOOR PLAN SCALE: 1/4 " -1' -0" ' 1/4 " =1' -0" ONE INCH AT FULL SIZE 1"'" - 66 NOe 432691 .no mum 04T CONTRACT N0: • C45153C F NOT ONE INCH. SCALE ACCORDINGLY sir[ LOCAnON Noe King County Department of Transportation MONO CRANE BRA <E '� GROOM . er- Y S CODE REVIEWED N C E a Q®v)e'nT fCfl • JAN 302006 City Of. Tilkvt' e BUTf_I T 1( ETON LEGEND AREA OF DEMO )4 METRO TRANSIT DIVISION SOUTH BASE MAINTENANCE BUILDING DUST COLLECTION SYSTEM UPGRADE PARTIAL ROOF & FIRST FLOOR DEMO PLANS CITYROF TUINVII_A• .JAN 1 a 2UO3 • PERMIT CENTER DAZE: OCT 2005 DRAWNO NQ . M1.01 SHEET NR OF 6 14 Inch 1/16 I_� N...- ..a....:r. _i • I 8 • NEW ROOF PAD IN FRONT OF MOTOR ASSEMBLY X PAINT BOOTH EXHAUST FAN EF -1 FOR CURBING DETAIL SEE AHU -107 A5.01 FOR DISCHARGE DUCT ' SUPPORT SEE DETAIL SEE NOTE 2 . A5.02 GUY WIRE SUPPORT_SEE DETAIL / 1 (NP) A5.02 • AHU -108. SEE DETAIL rTh A5.01 AS 1 SEE NOTE 1 • SCALE: 1 /4 " =1' -0" PARTIAL ROOF PLAN NEW ROOF PADS AHU -106 SEE DETAIL A5.01 • FOR EXHAUST FAN EF -2 INSTALLATION SEE PARTIAL PLAN SHOWN ON M5.01 FOR CURBING SEE DETAIL A5.01 X NOTES: 1. EXHAUST STACKS SHALL BE INSTALLED 10' -6" AWAY. FROM ALL OUTSIDE AIR INTAKES 2. DUCTING TO BE ROUTED. CLOSE TO WALL. AREA HAS AN OVERHEAD CRANE. 3. FOR FAN SCHEDULE SEE DWG M6.01. EXISTING PAINT BOOTH NEW 14 "0 DISCHARGE n DUCT FROM PAINT BOOTH —.. . M3.02 M3.02 EXISTING DUST COLLECTOR n9 J 1 21 r 7 SEE NOTE 2 NEW 14 "0 DISCHARGE DUCT FROM DUST COLLECTOR Albs II (L O BRA< PARTIAL 1 ST FLOOR �"„PIAN I M I OFOR CODE COMPLIANCE JAN 3 0 2006 City Of Tukwilri 3Iuitnirkin r r1 --F —F— ROOM R A •I 11 CITY OF TUKWILA JAN 18 2006 PERMIT CENTER No. REVISION BY APP'D DATE I ommo »/o/ DESIGNED: R NICHOLS DRAWN: B HAMBLIN CHECKED: J TURNER RECOMMENDER D CRIPPEN PROJECT MMMGER K MADDEN APPROVED: B ISLER IBIS NO: 432691 raw =um 04T - 32 CONTRACT NO: C45153C SCALE: 1/4 " =1 — O " ONE INCH AT FULL SIZE I IF NOT ONE INCH. SCALE ACCORDINGLY SnE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION SOUTH BASE MAINTENANCE BUILDING DUST COLLECTION SYSTEM UPGRADE PARTIAL ROOF AND 1ST FLOOR PLANS DATE OCT 2005 DRAWING NO: M1.02 SKEET NO: of 7 14 I II1 1 IIlrii1.lil.l. Inch 1116 • .' SI. H. CI. �' Z6 .II IllllpillIIIILliii Ia � : ,, b r } I Nayn .. L' , y • ( 5� V C l I., WO L��:I�II11 III �IIII1 .11111111! � II:IIIII IIII I !IIIl�111111I�IIIII�II)I� s . • ri • 38 c'> 0 REMOVE FAN FROM DUST COLLECTOR. REMOVE DISCHARGE DUCTING. P.O.C. • NORTH WALL TIRE SHOP SECTION • SCALE: 3/8 " =1' -0" M1.01 No. I• et 0 APP'D DATE PATCH CINDER BLX1K OPENING WITH LIKE MATERIAL PRIME & PAINT TO MATCH SOUTH WALL BRAKE SHOP SECTION SCALE: 3/8 • =1' -0' M1.01 • Imm3 1 REMOVE DUCTING FROM PAINT BOOTH Tx R NICHOLS REMOVE DUCTING TO WORK TABLE EXHAUST DTM RR B HAMBUN CNETJ®c .1 TURNER D CRIPPEN PROJECT MNNX/t K MADDEN APP110NDk B ISLER IBIS NR 432691 .a.: imar 047 CONTRACT N� C54153C WEST WALL ' ' BRAKE SHOP SECTION SCALE: 3/8"=1'-0" M1.01 SCALE: AS NOTED ONE INCH AT ' FULL SIZE MICR, SCALE IF NOT ACCORDINONE GLY SITE LOCATION NO: 1' CA Ting County Department of Transportation JAN 18 2006 PERMIT CENTER DISCONNECT FAN FROM BOOTH AND REMOVE REMOVE DUCTING. PANT BOOTH 70 RDAANJ Qty Of Tai MIT t. f)TIv Ar ... TABLE TO BE REPLACED WITH NEW DOWNDRAFT TABLE. RECEIVED CITY OF TUKWILA • . LEGEND METRO TRANSIT DIVISION SOUTH BASE MAINTENANCE BUILDING . DUST COLLECTOR SYSTEM UPGRADE SECTIONS CODE COMPLIANCE F - JAN 3 0 2006 • AREA OF DEMO DATES OCT 2005 DOOMING 301 SNILT NO; or 8 14 aii I I` uu101lI III I1.0 I II I�II~ IVI , rr II IIIIII!IIIIII IILIIIiIII 1 Inch 5L 44 EI ZI. L ii jiill:I. 1 111111! �iil. � .il.ii,lluuiiallli lii�llll l I. NO• ALIT IIIi_ IIII III (IIIIIII 1111111111.. FOR ROOF CURBING SEE 14 "0 DUCTIN FILL VOID WITH INSULATION AND SANDWICH WITH AN 18GA. WALL COVER. PAINT TO MATCH EXISTING WALL. (2 PLACES EACH SIDE) 9"0 TO NEW DOWNDRAFT BENCH. PROVIDE A HOLE IN THE CMU .WALL FOR THE NEW ROUTING OF THE EXHAUST DUCTING, FINISH WALL OPENING WITH RING AND PAINT TO MATCH WALL COLOR. A No. REVISION NORTH WALL TIRE SHOP . SECTION rioT SCALE: 3/r=1'-0' 111.02 BY APP'D DATE CORE DRILL CONCRETE PENETRATION (15 "0). (DO NOT SAW CUT). SEE NQIE.L, OFFSET DUCTING SO PENETRATION IS LOCATED EXACTLY 1/2 DISTANCE • BETWEEN THE CONCRETE STRUCTURAL SUPPORTS FOR ROOF CURBING SEE DETAIL A5.01 • PROVIDE A TRANSITION TO DUCTWORK FROM EXISTING ACOUSTIC BOX. GF INDEX TA3LE 0 • PATCHED AREA . 3 . 0 LOWER SUPPORT BRACKETS INSTALL EXTENSION ON EXISTING EXHAUST DUCT. POC . 4 "0 .ROC — T' DRUM LATHE I 4 SOUTH WALL BRAKE SHOP . SECTION SCALE: 3/8'=1' -0' M1.02 0 loaves nh/ / TABKE. MOVE DRUM LATHE 2' -0" , LAG . TO FLOOR WITH 1/4'0 X ' J ,.... 4" LONG HILTI BOLTS AT• (4) ' LOCATION C D GO� • R D C O� p 60130 on � n 206 0 DESIGNECA R NICHOLS OR IC B HAMBUN CMCIMM • J TURNER D CRIPPEN 5'0 '9"es—\ qt y Or wila‘l VILVO FRO= IMAGER K MADDEN APPROVECe B ISLER us NR 432691 van Komi; off CONTRACT PT* C45153C FOR ROOF CURBING SEE I .01 7"X10" DUCT ' ADAPT TO 9 "0. • WEST WALL BRAKE SHOP ECTION _ :3/8 "=1' -0' M1.02 1' CA SCALD AS NOTED ONE INCH AT FULL SIZE IF NOT ONE INCH. SCALE ACCORDINGLY SIZE LocAnON NO King County Deportment of Transportation 18 GA. WALL SUPPORT RING. FASTEN RING TO CINDER BLOCK•AND TO NEW DUCTWORK. (BOTH SIDES) PROMDE A 9"0 BLAST GATE TO NEW DOWNDRAFT BENCH. • NOTES: • SPLIT RING SUPPORT POINT NEAR ELBOW. 14'0 DUCTING TO ROOF CITY RECEIVE TUKWILA • . . JAN i 8 2006 . PERMIT CENTER 1. PRIOR TO ROOF CORE, CERTIFIED ROOF CONTRACTOR • TO PREPARE "CORE AREA'. REMOVE ALL ROOF MATERIALS TO ROOF DECK. SEAL. ALL ADJACENT & EXPOSED ROOF SYSTEM MATERIALS TO MAKE WATER • TIGHT. WORK TO BE APPROVED BY THE PROJECT REPRESENTATIVE. • METRO TRANSIT DIVISION SOUTH BASE MAINTENANCE BUILDING' DUST COLLECTOR SYSTEM UPGRADE SECTIONS OpUE OCT 2005 DRAINNO Noe M3.02 SKIT NOT or 9 . 14 Inch 1116 I11111 1 11 111I11111 111 1 56 ". 6 gV.e.Zl r OI I b AT ¢g '*.w.L,,.. r--•v x 9 1 IIIIIIIIuIILIIUIul umit ' 11 W0 IIIIIIIII DISCHARGE DUCT AND STACK SEE A5.02 GUY WIRE ANCHOR SEE (TYP. OF 3) A5.02 15' -0" 6' 4' T n■-• 4 • 1 PARTIAL ROOF PLAN SCALE: 1/2 " -1' -0" • TYPICAL EXHAUST FAN AND DISCHARGE DUCT SECTION SCALE: 1/2 " ■1' - - -- FOR WIRE DETAIL SEE M A5.02 17 "11 0.D. OUTLET DUCTING ENCLOSURE FLEXIBLE CONNECTION DUST COLLECTOR • EXHAUST FAN SEE DETAIL A5.02 14 "0 DUCTING FROM DUST COLLECTOR A5.01 WELD TRANSmoN DUCT TO DISCHARGE DUCT TRANSmON DUCT ALUMINUM ALLOY 3003 —N -14 14"x11" TO 24 "x11" (14 GAUGE) FLEXIBLE CONNECTION (INLET & OUTLET) EXHAUST FAN. TYP VIBFikTKON ISOLATOR FOR ENCLOSURE DETAIL SEE SECTIONQ A5.01 FOR CURBING DETAIL SEE A5.01 DISCHARGE DUCT STACK HEAD 18" INSIDE DIA. iIQIE; DISCHARGE DUCT AND STACK HEAD. ALUMINUM ALLOY 3003 —H -14 14 GAUGE. • WELDED CONSTRUCTION. SECTION SCALE: 1- 1/2" -1 -0" - -- SOD E p F° R- �IPL a 000.11/470 JAN 3 0 2006 . Qty Of kwi a j tn�AA (Sit ti Tr; 77'7 5 /8"DIA. SS BOLT a WASHER 1 112"DIA. SP:w"R 1/2 THICK LOCK NUT & WASHER TACK WELDED TO DISCHARGE DUCT CITY RECEIVED TUKWILA JAN 8 2006 PERMIT CENTER A A A A No. REVISION BY APP DATE OESIONE01 R NICHOLS mom B HAMOUN CHECKED J TURNER NECOIRIDEEDI D CRIPPEN PROJECT lAWICERt K MADDEN APPROVED B ISLER me HD 432691 gm MONO\ OR-02 COMA. T Moe C45153C SCALD AS NOTED ONE INCH AT FLU. SI E F NOT ONE INCH. SCALE ACCORDINGLY 10»a County Department of Transportation SITE IDGOION NOR ME TRANSIT DMSION SOUTH BASE MAINTENANCE BUILDING • DUST COLLECTION SYSTEM UPGRADE PARTIAL ROOF PLAN & SECTIONS Awe OCT 2005 DIMINO Mt SHUT Nn Of 10 14 g AI. GI. '.°'. Z I• : YY' II 911, IIIIlI. 1 I. Lii111ii IIIIIIIIIiIIII UIlll111iiiIJU1 .ul J • . EXHAUST FAN SCHEDULE • . • • MARK NO. • MODEL . NOMINAL CAPACITY (SCFM) ESP (W.C.) MOTOR HP ELECT (V/PH /HZ) REMARKS . • • • EF -1 GREENHECK TCBRV -2 -10 1375 1" 1 480/3/60 SHALL INCLUDE: MOTOR, COVER FOR MOTOR AND DRIVE, SPARK RESISTANT CONSTRUCTION, GRAVITY OPERATED DAMPER, WELDED CURB CAP, COMPANION FLANGES, INSPECTION DOOR, ISOLATORS, BIRDSCREEN ON DISCHARGE, INSULATED ROOF CURB . EF -2 NORTHERN BLOWER DESIGN 5010 FAN SIZE 1350 2300 6 8 . 5 •480/3/60 SHALL INCLUDE: VIBRATION ISOLATORS, OUTLET SCREEN, DISCHARGE AT 45' OUTLET, SPARK RESISTANT CONSTRUCTION, ACCESS DOOR AND INSULATED ROOF CURB • i l REVIEWED FOR CODE COMPLIANCE .. isvl®ei.. icr) JAN 302006 • City Of Tukwila . R Q n ,f (ta. CITY 0 TUKWILA JAN 1 8 2006 PEHIVIIT CENTER A No. REVISION BY APP'D DATE I oa•an H/r/ PROJECT MANAGER: C. STRONKS • APPROVED: B. 1 SLFR DESIGNER R NICHOLS DRAN7k 8 HAMBUN CNECI(ER J TURNER RECOMMENDED: D. CRIPPEN SCALE: • NONE ONE INCH AT FULL SIZE I- T -► IF NOT ONE INCH. SCALE ACCORDINGLY ME LOCATION NO, OS MR 432691 ya., ,mon O4T -32 CONTRACT NR . C45153C King County Department of Transportation METRO TRANSIT DIVISION SOUTH BASE MAINTENANCE BUILDING DUST COLLECTION SYSTEM UPGRADE MECHANICAL EQUIPMENT SCHEDULE DATE: OCT 2005 DRUNK s o1 SHEET NO: OF 11 14 I'l Inch 1/16 1 v1 1411 ..I I5 L l ti L £ L Z L L �; O 6 r r"zh B,ia IIIIII IIIII IILI1 II.IIIIII( ILIIIiIIJILILI . 1111 �I11lIIIIIIIJIIIIIII�I . IiII!Ii!JII I IIII o1 La WIV A No. V SEE NOTE 3 PAINT BOOTH EXHAUST FAN TO EXISTING START /STOP DISCONNECT AND CONTROLS - BELOW. SEE ONE UNE DIAGRAM C -38 REVISION V V 0 TO EXISTING 1START/STOP DISCONNECT AND CO DIAGRAM P1 - 26 SEE NOTE 3 P82 -65 ED BELOW. SEE ONE -UNE ,_D41ST COLLECTOR WIHAUST FAN SEE NOTE 1 84 PARTIAL ROOF TOP PLAN SCALE NONE ' NOTES 1. ALL EQUIPMENT SHALL MATCH EXISTING EQUIPMENT 2. THE CONTRACTOR SHALL INSTALL A NEW NEMA 3R 30A DISCONNECT 3. THE CONTRACTOR SHALL INSTALL A NEW WEATHERPROOF GFCI RECEPTACLE. RECEPTACLE SHALL BE WEATHERPROOF WHILE IN USE. 4. SEE ROOF TOP DETAIL . • BY APP'D DATE V - o I l Il IIIII Inch 1/16 I - . i t, .t1T I 4I. iTI El. o Z ._III III1111ILL lll1IIIIIIi1 .11.111 ll111 PB2 TO ROOF DISCONNECT 71J-116 TIRE SHOP 127 $TORAGE EXISTING 30A 128 DISCONNECT SCALE: NONE DARES 3/T/ PARTS ROOM 124 I :u m to I 8 -00 WELD SHOP 1 121 P ® T EXISTING RAUNT BOOTH MOTOR ST�t�FtT /STOP DISCONNEI TT B -00 0 EXISTING DpUST COLLECTO MOTOR PB -`'T NO 30A START P DI DNNECT DESIGNED: DRAB D CRIPPEN m CO m CO CO • • ■ ■ ■ ■ ■ ■ ■ ■ ■ I_IUI : r.nl Ir I� I� Irara r ararara�lra ra ra ra ra ra ra rarar. I m 2 IC. WATIINS 0 (1 RECOMMENDED: 1h n 01 CO CO m m CO CO PASSAGE 121 • BRAKE ROOM 126 K. WATIWS/D. NARA= IS.ER CHECKED: IBIS No: C. REYNOLDS row mama eRa! �1'r it-VIEWED M FOR-- CODE JAN 3 0 20 CONDUITS —� THRRAU ROOF. BETWEEN TEES OF PRECAST ROOF BEAMS. ADJACENT TO PIPE STAND RECEPTACLE CIRCUIT. JClty Of Tukwila PROJECT MANAGER: IC MADDEN APPROVED: CONTRACT NO: IIf 11T 0IIl ii I ii III{ I.I1 Ill ljl ICI ' LI; I. S I 1 I 61 iiiiIi 11.111 (iiii 11111.111.1 1.11_11110 II 111.11111! Ili�riliIIIIIIiliuillilil SCALE: AS NOTED ONE INCH AT FULL SIZE IF NOT ONE INCH. SCALE ACCORDINGLY SITE EOCA71011 NO: LOCATE EQUIPMENT STAND PER EQUIPMENT REQUIRMENTS. (SUBJECT TO CODE COMPLIANCE) I I ,III i j t: E ii air MOTOR -- RECEPTACLE START /STOP CIRCUIT ROOF DISCONNECT ✓ CO King County Department of Transportation 120V RECEPTAC LES M') NEMA 3R — POWER DISCONNECT SWITCH GRS COND UIT () NEW PAINT BOOTH EXHAUST MOTOR 1/2 GRS (3) 110, (1) #12G 1' GRS (3) #10. (1) #12G OTOR CONTROLLER EXISTING 30A DISCONNECT BOO SCALE NONE • J EXISTING PLUG BUS 'B' (PB -2) NEW DUST COLLECTOR EXHAUST MOTOR NEW NEMA 3R DISCONNECTS ONE—UNE DIAGRAM SCALE: NONE GRS CONDUIT CIYP) METRO TRANSIT DIVISION SOUTH BASE MAINT DUST COLLECTOR SYSTEM UPGRADE ELECTRICAL PLAN DIAGRAM & SECTION EQUIPMENT STAND. 1/2- GRS (3) #10. (1) #12G ROOF LEVEL 1' GRS (3) #10, (1) #124 EXISTING MOTOR CONTROLLER EXIS 3QA DISCONNECT RECEIVED CITY OF TUKWILA JAN 1 8 2005 PERMIT CENTER EQUIPMENT MOTOR DATE: OCT 2005 DRAWING NR E1.01 SHEET NO: OP 12 14 NORTH WALL TIRE SHOP ELEVATION SCALE: 3/13%.1 M1.02 No. I REVISION Bi APP'D DATE 1 - CA WEST WALL BRAKE SHOP ELEVATION SCALE: 3 /8' -1' -0 M1.02 SEE NOTE 1 EXISTING MOTOR: STA(T/STOP AND DISCONNECT Donn an -- I OEmONEL% L K. WATKINS K. WATKINS/D. C. REYNOLDS RE Ca�E� DEae D CRIPPEN GF INDTZ TABLE • PROJECT MNMCEVE K MADDEN //PROVED: ISUR BS NR 432691 wale Sam 04Ta2 CONMACT NR 0 DRUM LATHE SOUTH WALL BRAKE SHOP ELEVATION SCALE: 3/8 •1' -0 141.02 SCAM AS NOTED ONE INCH AT FULL WE I--L-1 F NOT ONE INCH. SCALE ACCORDINGLY SET[ IC JUl NR NOTES 1. THE CONTRACTOR SHALL REMOVE THE EXISTING CONDUCTORS FROM END TO END AND DISPOSE OF THEM. 2. THE CONTRACTOR SHALL INSTALL NEW CONDUCTORS FROM END TO END FOR THE NEW EQUIPMENT. 3 D(ISTING CONDUIT MAY. BE RE -USED FOR NEW CONDUIT RUNS. 4. UNUSEABLE CONDUIT SHALL BE REMOVED AND DISPOSED. 5, REMOVE AND PULL NEW WIRE. 6. REMOVE DOSTING AND REROUTE NEW CONDUIT. 1i LL0 r SEE NOTE 5 SEE NOTE 6 EXISTING DISCONNECT TO REMAIN. ' Ding Ccamty Department at Transportation TABLE CODE COMP COMPLIANCE CIAIDaeethli n JAN 3 0 ZOO6 City Of Tukwila ".I1T1 .., ,,,1 RECEIVED CITY OF TUKWILA JAN 1 8 2006 PERMIT CENTER METRO TRANSIT DMSION SOUTH BASE MAINT. OPS DUST COLLECTOR SYSTEM UPGRADE EXISTING ELECTRICAL ELEVATION OtlLt DCT 2005 MARRS i SW NR OF 13 14 IIII I .�. 1 .. Inch II 1111lnllrilithIIIiiuliilIliiilluii iiiiliul_IIia ill I 1 »--• 0 0 I / \ I I CA I I I I EXISTING I I SEE NOTE 1 I • .. . .. ' . EXISTING MOTOR CONTROLLER MOTOR START/STOP i 0 • I OM J BOX EXISTING 30A I DISCONNECT SEE NOTE 1 • I .. I NORTH WALL TIRE SHOP ELEVATION SCALE: 3/13%.1 M1.02 No. I REVISION Bi APP'D DATE 1 - CA WEST WALL BRAKE SHOP ELEVATION SCALE: 3 /8' -1' -0 M1.02 SEE NOTE 1 EXISTING MOTOR: STA(T/STOP AND DISCONNECT Donn an -- I OEmONEL% L K. WATKINS K. WATKINS/D. C. REYNOLDS RE Ca�E� DEae D CRIPPEN GF INDTZ TABLE • PROJECT MNMCEVE K MADDEN //PROVED: ISUR BS NR 432691 wale Sam 04Ta2 CONMACT NR 0 DRUM LATHE SOUTH WALL BRAKE SHOP ELEVATION SCALE: 3/8 •1' -0 141.02 SCAM AS NOTED ONE INCH AT FULL WE I--L-1 F NOT ONE INCH. SCALE ACCORDINGLY SET[ IC JUl NR NOTES 1. THE CONTRACTOR SHALL REMOVE THE EXISTING CONDUCTORS FROM END TO END AND DISPOSE OF THEM. 2. THE CONTRACTOR SHALL INSTALL NEW CONDUCTORS FROM END TO END FOR THE NEW EQUIPMENT. 3 D(ISTING CONDUIT MAY. BE RE -USED FOR NEW CONDUIT RUNS. 4. UNUSEABLE CONDUIT SHALL BE REMOVED AND DISPOSED. 5, REMOVE AND PULL NEW WIRE. 6. REMOVE DOSTING AND REROUTE NEW CONDUIT. 1i LL0 r SEE NOTE 5 SEE NOTE 6 EXISTING DISCONNECT TO REMAIN. ' Ding Ccamty Department at Transportation TABLE CODE COMP COMPLIANCE CIAIDaeethli n JAN 3 0 ZOO6 City Of Tukwila ".I1T1 .., ,,,1 RECEIVED CITY OF TUKWILA JAN 1 8 2006 PERMIT CENTER METRO TRANSIT DMSION SOUTH BASE MAINT. OPS DUST COLLECTOR SYSTEM UPGRADE EXISTING ELECTRICAL ELEVATION OtlLt DCT 2005 MARRS i SW NR OF 13 14 IIII I .�. 1 .. Inch II 1111lnllrilithIIIiiuliilIliiilluii iiiiliul_IIia ill ELECTRICAL PANEL SCHEDULE PANEL C BASE SOUTH DATE Oct-04 TYPE Sq. D, NOOB BLDG Maintenance SURFACE MOUNTED LOCATION Inspection Area, Cot B -3 MAIN BKR. 100A FEEDERS RATING 100A, 208Y/120V, 3PH, 4W FROM Panel A via 15KVA Transformer SHORT CKT. RTG Isym REF. DWGS. E105 REVISED CKT. REVISION(s) As Built DATE REVISED Jan -01 (CMS) ENGINEER CD REYNOLDS JOB NO. CIRCUIT 12 Receptacles 1a 3b 5c 7a 9b 11c 13a 15b 17c 19a 21b 23c 25a 27b 29c 31a 33b c 37a 39b 41c 2a 4b 6c 8a 10b 12c 14a 16b 18c 20a 22b 24c 26a 28b 30c 32a 34b 36c 38a 40b 42c FRAMES & AMPS 20A/1 P 20A/1 P 20A/1 P 20A/1 P 20A/1 P 20N1 P 20N1 P 20A/2P 20A/1 P 20A/1 P 20A/1 P 15A/1P 20A/3P 20A/1 P 20A/1 P 100A/3P 20A/1 P 20N1 P 20P11 20A/1 P 20N1 P 15A/1 P 20A/2P 20A/1 P 20A/1 P 15N1P 40A/2P 20A/1 P 2 0N1 1? 20A/1 P 20A/1 P 20A/1 P 20A/1 P WIRE SIZE LOAD DESCRIPTION HP 12 Lighting 12 12 12 (DL) 12 (DL) 12 (DL) 12 12 12 12 12 12 12 12 12 12 12 12 12 12 Receptacles (drop) Receptacles (drop) Receptacles Receptacles Receptacles Receptacles (drop) Receptacles (drop) Space Receptacles Receptacles Receptacles Spare Recept Shed Lt HW Tank 12 Receptacles eceptac es 6 Main Breaker 6 12 Receptacles S are 12 Fuel Management Spare 12 Fire Valve Pit Sump Pump 12 Hot Water Heater 12. I Space Roof Recpt Spare 1/4 MEF 12 Exhaust Fan .1/2 Spare MEF -101 Exhauxt Fan Recept Shed Lt HW Tank Receptacles Receptacles Receptacles Receptacles (Space DEMAND kVA- 1.0 CONNECTED kVA- 1 Ground - 0 Neutral - 25 AMPERES a b c 0.4 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.5 0.2 4 , 4.3 2 29.4 Neg 2.7 LOCATION Lube Utility Tunnel Inspection Pit 101 Inspection Pit.101 Inspection Pit 101 Inspection Pit101 Inspection Pit101 Chassis Shop 104 Chassis Shop 104 Chassis Shop 104 Chassis Shop 104 Chassis Shop 104 So. Wash Shed So. Wash Shed o. as e • Inspection Shop 101 Inspection Shop'101 Restroom. Insp Shop Roof Pit Root Col C -13 (Rm 103) Roof, Col B -10 No. Wash Shed No. Wash Shed No. Wash Shed Roof, Col B -13 Roof, Col B -12 TOTAL AMPS Measured Load A A BY APP'D GTE Dawn an/ cesKacce K. WATiONS K. WATKNS DIECKEIX C. REYNOLDS iacawoeEDe D CRIPPEN PlIOJECT 104040IQ K W100EN APP11o1EOe B ISLER Oi NR 432691 gm mum OST-31 COMACT Noe SCAM AS NOTED ONE INCti FULL SIZE AT F NOT ONE INCIL I ' I SCALE ACCORDINGLY NOTES 1. THE CONTRACTOR SHALL ADD RECEPTACLE CIRCUITS 38 & 40 TO ELECTRICAL PANEL C. CODE REVIEWED FOR A®ennvcro JAN 3 2O01 City Of Tukwila METRO TRANSIT DMSION SOUTH BASE MAINT. OPS DUST COLLECTOR SYSTEM UPGRADE PANEL SCHEDULE RECEIVED CITY OF TUKWILA JAN 18 2000 PERMIT CENTER ON6 OCT 2005 DIAMIMI 83.01 91ELT NOt ce 14 14 III II "ij1 I III II II1;1 Inch . 1/16 I ;:7" .II I Z :. II I I I , I I I I L I1� I I I 1I1•IFIII1IfjJI 1•II III . 6 WO LI 111111LI. I .IIILI1.111IIIII.I.IIIIli1.11), lllllll 111 .I1t !!lIIIIIIlJIIIIILLIIIIi�IW n iJlfLllllIiI IlIIIIIJI .