HomeMy WebLinkAboutPermit M06-007 - KHAN RESIDENCE - LOT 1KHAN RESIDENCE
LOT 1
13821 MACADAM RD S
EXPIRED
M06 -007
City end Tukwila
Parcel No.: 3229200010
Address: 13821 MACADAM RD S TUKW
Suite No:
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206- 431 -3665
Web site: ci.tukwila.wa.us
Tenant:
Name: KHAN RESIDENCE - LOT 1
Address: 13821 MACADAM RD 5, TUKWILA WA
Owner:
Name: AIA INTERNATIONAL VENTURES
Address: 24719 43RD AVE SOUTH, KENT WA
Contact Person:
Name: SUKHCHAIN SANDHU
Address: 306 N 1 AV, KENT WA
Contractor:
Name: MIDLAND MECHANICAL LLC
Address: 11212 SE 179 ST, RENTON WA
Contractor License No: MIDLAML9796T
DESCRIPTION OF WORK:
NEW HEATING SYSTEM FOR NEW SFR
Value of Mechanical: $5,275.00
Type of Fire Protection:
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended /Wall /Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat/Refrig /Cooling System
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial /Industrial
doc: IMC- Permit
MECHANICAL PERMIT
Permit Number:
Issue Date:
Permit Expires On:
gQUIPMENT TYPE AND QUANTITY
* *continued on next page **
M06 -007
Phone:
Phone: 425 766 -9867
Phone: 425 228 -4715
Expiration Date:09 /30/2007
Steven M. Mullet, Mayor
Steve Lancaster, Director
M06 -007
01/26/2006
07/25/2006
Fees Collected: $223.48
International Mechanical Code Edition: 2003
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 1
Wood /Gas Stove 1
Water Heater 1
Emergency Generator 0
Other Mechanical Equipment... 0
Printed: 01 -26 -2006
doc: IMC- Permit
City & Tukwila
Permit Center Authorized Signature: k1/Ai/Ip1.l
Signature: A
Print Name: �(t h \ 1 \ L A
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206.431 -3670
Fax: 206 - 431 -3665
Web site: ct.tukwila.wa.us
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Number: M06 -007
Issue Date: 01/26/2006
Permit Expires On: 07/25/2006
Date: 0112(s/a,
I hereby certify that I have read and ems. amined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or th- • - rformance of work. I am authorized to sign and obtain this mechanical permit.
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
M06 -007 Printed: 01 -26 -2006
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 3229200010
Address: 13821 MACADAM RD S TUKW
Suite No:
Tenant: KHAN RESIDENCE - LOT 1
1: ** *BUILDING DEPARTMENT CONDmONS * **
PERMIT CONDITIONS
%Nx
Permit Number: M06-007
Status: ISSUED
Applied Date: 01/19/2006
Issue Date: 01/26/2006
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: Manufacturers installation instructions shall be available on the Job site at the time of inspection.
6: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
7: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances
shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms,
bathrooms, toilet rooms, storage closets, surgical rooms.
8: Equipment and appliances having an Ignition source and located in hazardous locations and public garages, PRIVATE
GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that
the source of ignition Is not less than 18 Inches above the floor surface on which the equipment or appliance rests.
9: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall
be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum
distance of 4- inches shall be maintained above the controls with the strapping.
10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of
Public Health - Seattle and King County (206/296 - 4932).
11: All electrical work shall be Inspected and approved under a separate permit issued by the Washington State Department
of Labor and Industries (206/248- 6630).
12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The Issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors In the construction documents and other data.
* *continued on next page **
doe: Conditions M06 -007 Printed: 01 -26 -2006
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work.
Signature: ( Ir Date: I \,c �\ C
1
Print Name: S UY1C
doc: Conditions M06 -007 Printed: 01 -26 -2006
CITY OF TUKWILA
Community Development artment
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print'
QQ King Co Assessor's Tax No.: ? '2,2,c1 Zc9b010
Site Address: O l Mt; ' Yr) CLD S Suite Number: Floor:
Tenant Name: � � 1/4.0.\ New Tenant: ❑ .... Yes ❑ -No
Property Owners Name: cri � r k ca
Mailing Address: 3 6 t1 / 4t1 L
Name: LJ
Mailing Address: a
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
"An original or notarized copy of current Washington Sta
A vq
E -Mail Address:
GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor'iafoemation on back page
Company Name:
Mailing Address:
ARCHITECT OF RECORD - All plans must b • wet stamped by Architect of Record
ENGINEER OF RECORD -Al • sans must be wet stamped by Engineer otRecord
Company Name: / -
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: / Fax Number
Operant pblirc duna`paad appliutue (7.2004)
tie 644$
tie
Page 1
Building Penn .yso,.`
Mechanical Permit N
Public Works Permit
Project No
111
State
'as-
D� Telephone:
t
City
Fax Number:
C d 1 z
State Zip
City
Day Telephone:
Fax Number:
Expiration Date:
Contractor License must be presented at the time of permit issuance**
City
Day Telephone:
Fax Number.
Slate
. Slate
c S
Zip
�b b
Zip
Zip
Zia
Valuation of Project (contractor's bid price): S Existing Building Valuation: S
Scope of Work (please provide detailed information):
Will there be n• rack storage? ❑..Yes ❑.. No If "yes ", see Handout No. for requirements.
Provide All Building Areas in Square Footage Below
1" Floor
Z Floor
3" Floor
Floors
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
fisting
PLANNING DIVISION:
Single - family building footprint (area of the foun
Interior
Remodel
FIRE PROTECTION/HAZA OUS MATERIALS:
Addition to
Existing
Stmcture
oristrtiction
New per IBC
n of all structures, plus any decks . or 18 inches and overhangs greater than 18 inches)
Type of
Occupancy pei
IBC
For an Accessory dwelling, provide the foil ing:
Lot Area (sq ft): Fl. ' area of principal dwelling: Floor area for accessory dwelling:
'Provide documentation that shows t the principal owner lives in one of the d ° lings as his or her primary residence.
Number of Parking Stalls Provided: tandard: Compact: Handicap:
Will there be a change in use? ❑ ..Yes ❑ ..No If "yes ", explain:
❑.. Sprinklers ❑. • utomatic Fire Alarm ❑..None ❑ . Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑..Yes ❑..No
If "yes ", attach list of materials cold storage locations on a separate 8 -1/2 x II paper indicating quantities and Material Safety Data Sheets.
9 :Wpamits *skim changes pe n it application (7-2004)
Revised: 6SOS
bh
Page 2
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Fumace<100K BTU
1
Air Handling Unit >10,000
CFM
Fire Damper
0-3 HP /100,000 BTU
Fumace>100K BTU
96
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /I,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Water Heater
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig/Cooling
System
Incinerator - Domestic
-
Emergency
Generator
Air Handling Unit
<10,000 CFM
Incinerator — Comm/Ind
Other Mechanical
Equipment
MECHANICAL PERMIT INFO1 tTION 206-431 -3670
MECHANICAL CONTRACTOR INFORMATION
Company Name: M(b LO PI ° rrieck G h ( C
Mailing Address: \\ a L .S E - 7- q'Ch
City Slate Zip
Day Telephone: 1 j ^ �a �— U �)
q Fax Number:
Contractor Registration Number: P1 I l7 1 - et YY L ¥ 1 T Expiration Date:
**An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance**
Valuation of Project (contractor's bid price): $
a 7S' VI)
Scope of Work (please provide detailed information): f -{ P C t, \ t" h
Contact Person: elt L_
E -Mail Address:
Use: Residential: New ....Pic Replacement ❑
Commercial: New .... ❑ Replacement ❑
Fuel Type: Electric ❑ Gas ....0 Other:
Indicate type of mechanical work being installed and the quantity below:
PERMIT AFFLICATION NOTES Applicable to alt permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 1110 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested
in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT + 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THI? PERMIT.
BUILDING 0 O A
Signature:
GENT:
�U IS M tr "1
Print Nanie
Mailing Address: 1 O . A / ) SC i 4 '" e C
I Date ApplicationAccepted:O�`
6.0paaits pSa im a aNr•Vuaa "Oration ( g4)
Revised. 64-05
Page 4
I L
Kevi 1/4) Y) ciarb_fr
c4
Date: 1 n Day Telephone: ti a l' b 907-
City
State
Date Application Expires:
63--2o
- Staff Initial
I
VVIBLlemiat KSP;
Scope of Work (please provide detailed information):
Water District
❑ ...Tukwila
❑...Water Availability Prov ed
Sewer District
❑...Tukwila
❑...Sewer Use Certificate
❑...Septic System - For onsite sep
❑...Total Cut
❑ ...Total Fill
❑...Water District #I25
cubic yards
cubic yards
❑...Sanitary Side Sewer 0.. Abandon S •tic T
❑ ...Cap or Remove Utilities ❑ .. Curb Cu
❑ ...Frontage Improvements ❑ .. Pavem • t Cut
❑...Traffic Control .. Loo : Fire Line
❑...Backflow Prevention - Fire Protection
Irrigation
Domestic Water
Call before you Dig: 1- 800 - 424 -5555
Please refer to Public Works Bulletin #1 for fees a nd estimate sheet.
❑ .. Highline ❑ ...Renton
...ValVue ❑.. Renton ❑. .cattle
.. Sewer Availability Provided ❑ .. Approved Septic Plans Pro • ed
system, provide 2 copies of a current septic design approv by King County Health Department.
Submitted with Application (mark ho. s which apply):
❑...Civil Plans (Maximum Paper Size 22" x34 ")
❑...Technical Information Report (Storm nage) ❑ .. Geotechnical rt ❑...Traffic Impact Analysis
❑...Bond ❑..Insurance ■..Easement(s) ❑..Maintenanc ement(s) ❑...Hold Harmless
Proposed Activities (mark boxes that apply):
❑ ...Right -of -way Use - Nonprofit for less than 7 ours ❑ .. Righ . -way Use - Profit for less than 72 hours
❑ ...Right -of -way Use - No Disturbance ❑ .. Ri -of -way Use — Potential Disturbance
❑ ...Construction /Excavation/Fill - Right -of -way
Non Right -of -way
.. Work in Flood Zone
❑ .. Storm Drainage
❑ .. Grease Interceptor
❑ .. Channelization
CI.. Trench Excavation
❑ .. Utility Undergrounding
❑...Permanent Water Meter Size... WO#
❑...Temporary Water Meter Size .. WO#
❑...Water Only Meter Size - WO# ❑...Deduct Water Size
❑ ...Sewer Main Extension Pub Private
o ...Water Main Extension P . ic, Private
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
❑...Water
Monthly Service Billing to:
Name:
Mailing Address:
Water Meter Refund/Billing:
Name:
Mailing Address:.
❑...Sewer
q:itpamia *slice d angeo prank application (
aaanad: e•ws
ea
❑ ...Sewage Treatment
Page 3
Day Telephone:
city
City State
State Tip
Day Telephone:
RECEIPT NO: R06 -00116
Initials: JEM
User ID: 1165
Payee: AIA CONTRACTING INC.
SET TRANSACTIONS:
Set Member Amount
1406 -006 184.78
M06 -007 184.78
1406 -008 184.78
TOTAL: 554.34
ACCOUNT ITEM LIST:
Description
MECHANICAL - RES
C of Tukw Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
SET RECEIPT
Copy Reprinted on 01 -26 -2006 at 14:09:03 01/26/2006
Payment Date: 01/26/2006
Total Payment:554.34
SET ID: 11206 SET NAME: KHAN DEVELOPMENT
TRANSACTION LIST:
Type Method Description Amount
Payment Check 3345 554.34
TOTAL: 554.34
Account Code Current Pmts
000/322.100 554.34
TOTAL: 554.34
1669 01/26 9710 TOTAL 554.34
RECEIPT NO: R06 -00077
Initials: JEM
User ID: 1165
Payee: RUPINDER KAUR
SET ID: 5000000426
SET TRANSACTIONS:
Set Member Amount
M06 -006 38.70
M06 -007 38.70
M06 -008 38.70
TOTAL: 116.10
r ji r of Ti'kw
TRANSACTION LIST:
Type Method Description
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
SET RECEIPT
Payment Date: 01/19/2006
Total Payment:116.10
SET NAME: Tmp set/Inftialized Activities
A moun t
Payment check 632 116.10
TOTAL: 116.10
ACCOUNT ITEM LIST;
Description Account Code Current Pmts
PLAN CHECK - RES 000/345.830 116.10
TOTAL: 116.10
1398 01/19 9710 TOTAL 116.10
Steven M. Mullet. Mayor
Steve Lancaster, Director
Project 4 4 Lei 4 A--
Type of I ;e
n: � �C/ N.-
Addreessss:
/22-2 3 A
Date Called:
Special Instructions:
Date Wanted:
� :m;
Requester:
Phone No:
INSPECTION NO.
El Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
✓14os- 7
'Corrections required prior to approval.
A G, 77-4 �t
COMMENTS )
- fns /I✓7 L T
7a 4- yei� /- fi��?� ‘1 in ,9/�
7 / y/ r.1 , : ^ 3 .5 y i 4-, . J L 7 4 it*
,;1 (j /
Inspectors
tit .t !
(Date: " ,,,/
pi $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
Date:
..
Project:
KNAIv Red• Lost
Type of Ins c t'on: ria
0/ h i
Address:
)3 &a1 rn M r MSA+tn P-S
Date Called:
' -- 1y -OC,
Special Instructions:
Date Wanted: a.m.
2 . — f 5 --o ()p.m.
Requester:
Phone No:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
time -
PE l N .
CITY OF TUKWILA BUILDING DIVISIO
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367
COMMENTS:
Nt h —2:1 — 4pri/g
Date: ,,r
�— ��t0
.00 REINSPECTION FEE RgUIRED. Prior p6 inspection, fee must be
d at 6300 Southcenter Blvd. Suite 100. 11 to sechedule reinspection.
Re ; pt No.:
Date:
Approved per applicable codes. ['Corrections required prior to approval.
•
SEPARA
as
,REQUIRED FOR:
Q/
mech ) bm
����'' pl
p Plumbing
City Of 1bkw'
L ttfMeP
c'
I. WASHINGTON STATE ENERGY CODE HEATING DESIGN METHOD (select A, Br Igt
Site Address: ) 3 S 2 ) 11"\ f Cp‘1)
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd.; Suite 100
Tukwila, WA 9 188
N
Component Performance Approach - W.S.E.C. Chapter 5
Prescriptive Option — W.S.E.C. Chapter 6 (for prescriptive
House Square Footage (heated space): a 2 Z%
X 20 BTU/h
v g �� MaxiRlt7t5r
Heating System Installed, (check system type below):
1. ❑ Electric Resistance
2. ❑ Electric (forced air)
Other Fuels (gas, heat pump)
A.
B.
c.
if
r i
i
iffy
5
'6 E
1 11
System Analysis — W.S.E.C. Chapter 4 (submit documental/Si
ON STATE VENTILATION AND INDOOR AIR OUAI ITY CODE (select A or B below):
Ventilation by Performance or Design Method - W.S.V.I.A.Q. Section 302 (submit documentation).
Prescriptive Ventilation Options - W.S.V.I.A.Q. Section 303 (select one of the following):
❑ Ventilation using Exhaust Fans (Section 303.4.1.)
❑ Exception for outdoor air inlets — Forced air heating system w/interior doors undercut Va'
❑ Ventilation integrated with Forced Air System (Section 303.4.2.)
❑ Ventilation using Supply Fan (Section 303.4.3.)
❑ Ventilation using Heat Recovery System (Section 303.4.4.)
1.
2.
3.
4.
Prescriptive Minimum/Maximum Outdoor Air Calculation specified in Table 3 -2 (see reverse side of form).
1. House Square Footage: cz. ,1 2Z
2. House Number of Bedrooms:
3. Required Outdoor Air Table 3 -2: Minimum - r tre) cfm
Maximum - / S cfm
Effective: THAN
1ppNcalionse bq .m ventilation "Own - ram h4 (7-20M)
IAL HEATING AND VENTILATION COMPLIANCE FO ZM
e Sections I and II for Group R Occupancies 4 Stories or Lem
MECHANICAL PERMIT APPLICATION NO.: )LX(.t ON" BI III
BUILDING PERMIT APPLICATION NO : p d' 1 S
•
h ` gees; D-on W 1
Permit Center/Building Division:
206 -431 -3670 RE �I
Public Works Department: CODEOOMPl1AN
206-433-0179
Planning Division: somata /WM
206.431 -3670
kb, S kw A -
rr�..
JAN 2 4 2006
o�kw E
DTN( flMS
Nat la entire aXI MINI
if i r eindtbre A Kb
S tern Output
aPdL meigageb n
JAN 2
a
PERMIT CENTER
A
V-J
tas
—In
TABLE 3-2
VENTILATION RATES FOR ALL GROUP R OCCUPANCIES FOUR STORIES OR LESS
Minimum and Maximum Ventilation Rates: Cubic Feet Per Minute (OM)
1001 -1500
2001 -2500
twimo
bLivint
nn"; 145
s ir":• 165 2b8 .180 270 195 293 21
LIN •ma. mpg
-- -- -- - -- -- 190
rani} faitiktrgtS:Egt
2 or less
Min " Max
50 75
3 4 5 6 7
Min Max Min Max Min Max Min Max Min ax Min
65 98 80 '120 95 143 110 165 125 8 140
DT ?fl r 1 :fit
Floor
,Area, ft2
MOWN
t • rooms, in ase the minimum requirement listed for 8 bedrooms by an additional 15 CFM per
room. The maximum CPA is equal t5 times the minimum.
<500
Max
:t10
Fan Tested CFM
0.25" W.G.
50
50
80
100
125
Minimum Flex
Diameter
4 inch
p
6 inch
5 inch
et
5 inch'
6 inch
Maximum Length
Feet
25
No Limit
15
NA
15
Minimum Smooth
Diameter
4 inch
lit
6 inch
5 inch
5 inch
6 Inch
Maximum Length
• Feet
70
No Limit
100
50
rzr
No Limit
Maximum
Elbows'
3
3
3
3
1. For each additional e bow subtract 10 feet from length.
2. Flex ducts of this diameter are not permitted with fans of this size.
Bedrooms
TABLE 3 -3
PRESCRIPTIVE EXHAUST DUCT SIZING
01-02 -2007
SUKHCHAIN SANDHI]
306 N 1 AV
KENT WA 98032
RE: Permit No. M06-007
13821 MACADAM RD S TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for
additional periods not exceeding 90 days each. Extension requests must be in writing and orov setsfacton reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 02/07/2007 , your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
xc:
City of Tukwila Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
Permit File No. M06-007
•
•
•
•
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 -431 -3665
July 28, 2006
Sabir Khan
306 N 1 Ave
Kent WA 98032
City of L uktvila Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
RE: Request for Extension
Mechanical Permit No. M06 -006 & 007
Khan Development, Lots 1 & 2
Dear Mr. Khan:
This letter is in response to your written request for an extension to Permit No. M06 -006 & 007. The
Building Official has reviewed your letter and considered your request to extend the above referenced
permit. The City of Tukwila Building Division will be extending your permit through February 10, 2007
as requested.
If you should have any questions, please contact our office at (206) 431 -3670.
Sincerely,
arshall
chnician
File: Permit No. M06 -006 & 007
P:Vennifer\Extension Letters \Pemuts\M06 -006 & 007 Permit Extension4oc Page I of 1
jem
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206-431-3665
07/26/2006 00:55 2538547027
6300 Southcentre Blvd suite #100
Tukwila WA 98188
Dear Jennifer:
I am writiog this later regarding permit #404- 255 /d04256/d04257 and permit #m06-006 /mo6 -007 and
mo6- 008. as you are aware of we had a no work order on the property and had to file for a revision on the site
and now we are currently working on the property,I would like to kindly request an extension on the above
mention permits and would really appreciate your help in this matter. If you have any questions please call me
at 253 -261 -9716
e .P11/l4AArd pea SabirKhan
Nor(c• 2-Th E,1C-�—
0 1)0 4 -2555 GVo3 /0 ot/13V0
boo - 2S10 0 /0b 0
bog- 257 ,e( &Vto /o7
MoG -bLb v7 /U /u4 007/0
Mo& -007 0 -7/U344, del 1/0
AMERICAN CANADIAN RE PAGE 02/03
July 17, 2006
Sincerely,
CITY
JUL 26 2006
PERMITcENT
40,K.4) iscreht4 l8
�i��l -3 D2- II
07 -03 -2006
SUKHCHAIN SANDHU
306 N 1 AV
KENT WA 98032
RE: Permit No. M06 -007
13821 MACADAM RD S TUKW
Dear Permit Holder:
City of Tukwila
Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for
additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 08/14/2006, your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
M. rshall,
P�'mit Tec 'cian
XC:
Permit File No. M06 -007
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431.3665
ACTIVITY NUMBER: M06 -007 DATE: 01 -20 -06
PROJECT NAME: KHAN RESIDENCE
SITE ADDRESS: 13821 MACADAM RD S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Issued
DEPARTMENTS:
L ( �
Bui idnig Division
Public Works
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUT NG:
Please Route Structural Review Required ❑ No further Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Notation:
REVIEWER'S INITIALS:
Documemshouting slip.doc
2 -28-02
pis PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
Structural
Incomplete ❑
Approved with Conditions
� I Rt6- fr I_J
Fire Prevention
❑ Permit Coordinator ❑
DUE DATE: 01 -24-06
Not Applicable ❑
DATE:
DUE DATE: 02-21-06
Not Approved (attach comments) ❑
DATE:
Planning Division
n
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
MIDLAML9796T
Licensee Name
MIDLAND MECHANICAL LLC
Licensee Type
ELECTRICAL CONTRACTOR
UBI
602318064
Ind. Ins. Account Id
PARTNER/MEMBER
Business Type
LIMITED LIABILITY COMPANY
Address I
11212 SE 179Th ST
Address 2
City
RENTON
County
KING
State
WA
Zip
98055
Phone
4252284715
Status
ACTIVE
Specialty I
HVAC/RFRG- RESTRICTED
Specialty 2
UNUSED
Effective Date
9/30/2003
Expiration Date
9/30/2007
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
MERCIJ•967PM
Business Owner Information
Name
Role
Effective
Date
Expiration
Date
SCELLATO, STEVE
PARTNER/MEMBER
09 /30/2003
MERCIER, JEAN -
PAUL
PARTNER/MEMBER
09/30/2003
Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2
Washington State Department of Labor and Industries
Electrical Contractor
A business licensed by L &I to contract electrical work within the scope of
its specialty. Electrical Contractors must maintain a surety bond or
assignment of savings account. They also must have a designated
Electrical Administrator or Master Electrician who is a member of the
firm or a full -time supervisory employee.
Electrical Administrator Information
License
Name
Status
MERCIJ•967PM
MERCIER, JEAN -PAUL
ACTIVE
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= MIDLAML9796T 01/25/2006