Loading...
HomeMy WebLinkAboutPermit M06-009 - WASHINGTON MUTUALWASHINGTON MUTUAL 3355 S 120 PL M06 -009 Parcel No.: Address: Suite No: Tenant: Name: WASHINGTON MUTUAL Address: 3355 S 120 PL, TUKWILA WA Value of Mechanical: 538,108.00 Type of Fire Protection: City to Tukwila Contact Person: Name: MAX HARSHMAN Address: 1161149 PL W, MUKILTEO WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us 1023049069 3355 S 120 PL TUKW Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 MECHANICAL PERMIT Owner: Name: SABEY CORPORATION Address' 12201 TUKWILA INTL BLVD 4THFL, SEATTLE WA Contractor: Name: UNIVERSITY MECHANICAL CONTRACTOR Address: 1300 N 130, PO BOX 33723 Contractor License No: UNIVMC *343N9 DESCRIPTION OF WORK: PROVIDE ROOF DUCTWORK AND ISOLATION DAMPERS FOR FM -200 SYSTEM Permit Number: Issue Date: Permit Expires On: EQUIPMENT TYPE AND QUANTITY * *continued on next page ** Phone: Phone: 206 368 -6242 Phone: 206 - 364 -9900 Expiration Date:10 /03/2006 Steven M. Mullet, Mayor Steve Lancaster, Director M06 -009 02/17/2006 08/16/2006 Fees Collected: $4,712.51 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 80 Thermostat 1 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment... 133 doe: IMC- Permit M06 -009 Printed: 02-17-2006 Permit Center Authorized Signature: City & Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -009 Issue Date: 02/17/2006 Permit Expires On: 08/16/2006 Date: 024n-tip I hereby certify that I have read and in is permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constrt ctjon or the perforppnce of work. I am authorized to sign and obtain this mechanical permit. Signature: �.7(/R ./ Date: 2 10 Print Name: DOm //7t �/% e loser trr This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doe: IMC- Permit M06 -009 Printed: 02-17-2006 a City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1023049069 Address' 3355 S 120 PL TUKW Suite No: Tenant: WASHINGTON MUTUAL 1: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: M06 -009 Status: ISSUED Applied Date: 01/20/2006 Issue Date: 02/17/2006 2: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 3: Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. (IFC 901.4) 4: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 5: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to Installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 6: All new automatic fire- extinguishing systems and all modifications to existing automatic fire- extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. (Installation of the FM 200 supression system requires a separate fire department permit). 7: Local U.L. central station supervision is required. (City Ordinance #2051) 8: Maintain fire alarm system audible /visual notification. Addition /relocation of walls or partitions may require relocation and /or addition of audible /visual notification devices. (City Ordinance #2051) 9: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code (NFPA 70) 10: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 11: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not Imply approval of such condition or violation. 12: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Conditions * *continued on next page ** M06 -009 Printed: 02 -17 -2006 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: /a-f4.42% — Date: 03/47 /Mo Print Name: D /l7vl ft7 /7aF jfn or,s- doc: Conditions MO6 -009 Printed: 02 -17 -2006 (1 ipp6ecct - f l'orN Only SITE LOCATION Site Address: - 120 P2-- Tenant Name: 111/1 king n MU/va l New Tenant: Property Owners Name: y Mailing Address: Zip CONTACT PERSON Name: filmy /Jotnh» ctr.- ,�ll Day ,2n(O- 3(oe - (0,24.2_ Mailing Address: /1 6 7 11 -41 PL (A) 47(44h-to Ui/F c7R n ff City State Zip E-Mail Address: (r)GVC 1/2 i'51)ma✓I ( F71CLCO✓'— Fax Number: GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page) Company Name: Mailing Address: Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: **An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance** ARCHITECT OF RECORD - Mi plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: haf CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ry(batnit. plusbcc chata®b.nnitappl icauoa (7.2004) Raised 64-05 bh Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** UYI ive r� if ( /}?2c`la n Ica Page I Building Permit No. 004e-45 A Mechanical Permit No. �(/. ` tom Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: 1 0 2 - ki4 - `tnt' 1 Suite Number: City Floor: 2 ❑ Yes .No State State state Zip 11(011 4 V F! id/ Makithen UDR `'e0 -75 City Day Telephone: Fax Number: ' I II� City state Zip �' / nXSY1ifl r Day Telephone: 0 2o62 - 5& el -to 24 a y oxhav5hmari (IrnCit, - Fax Number: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<100K BTU AEA Air Handling Unit CFM 8 NI A' $ireDam r 4rnoKe. n MIA 0-3 HP /100 BTU N l Fumace>100K BTU /V /fr Evaporator Cooler d/ /4 Diffuser u a. 3 -15 HP /500,000 BTU A/ /4 Floor Furnace /U//t Ventilation Fan Connected to Single Duct 44 Thermostat �/� 15 -30 HP /1,0(10,000 BTU N ot Suspended/Wall/Floor Mounted Heater N/A Ventilation System w Wood/Gas Stove NgR 30-50 HP /1,750,000 BTU WA. Appliance Vent /V/A' Hood and Duct ^/JA- Water Heater A![+ 50+ HP /1,750,000 BTU 4/IA- Repair or Addition to Heat/Refrig/Cooling System NIA Incinerator • Domestic A/44- Emergency Generator �/� Cnn +JO t 1 0110212 2 Air Handling Unit <10,000 CFM A/h Incinerator- Comm/Ind v/A Other Mechanical Equipment N/ 4 , - t MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL CONTRACTOR M INFORMATION Company Name: 011 ilk 1r51 , /� leriir link I L ,//� Mailing Address: ( R (0 I I 4 Q+" Pt- (.V /n! Jki'I feel Cii 1 27 5- ��//�� ll t'T LI� CA (r City state Zip Contact Person: ///ate VSVIWIGV'. Day Telephone: 2D Co- 3 4 - Cow -42. E -Mail Address: VY1OW h a ✓syl vY n N 01 0 e , Co r- Fax Number: Contractor Registration Number: 0A /111M G * 34 3 A/ 9 Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ ¶3R, /n3 Scope of Work (please provide detailed information): f u (d 2 Pon-P du c{ua np it 4' rto /a "how da mpg 13 -4v r. Fin -2n0 - sys4rn'I • jJcg Residential: New .... Replacement .... ❑ Commercial: New... Replacement.... Fuel Type: Electric ❑ Gas....❑ Other: /t//A' Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction -In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AM) EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE UTHO E AGENT• Signature: `.i��t (( • , Max /ar'S n QV\- Aoki' 200» -3Coa -Co24 Mailing Address: .11.0 49 P�- U) //I!/ki'Ife_n I 44 cis 27r City State Zip Print Name: Date Application Expires: Date Application Accepted: e \pmnia pho4cc chanrretpe,mit application (7 -2001) Revised 65 -05 bit . 0(1 Page 4 Date: (/q /v& Staff Initials: i Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: City of Tukwila 1023049069 3355 S 120 PL TUKW WASHINGTON MUTUAL R06 -00721 3EM 1165 TRANSACTION LIST: Type Method Payment Check ACCOUNT ITEM LIST: Description doc: Receipt 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 UNIVERISTY MECHANICAL CONTRACTORS, INC. MECHANICAL - NONRES PLAN CHECK - NONRES Description 251142 Account Code 000/322.100 000/345.830 RECEIPT Permit Number: Status: Applied Date: Issue Date: Payment Amount: Payment Date: Balance: Amount 1,550.72 Current Pmts 1,240.57 310.15 Total: 1,550.72 M06 -009 ISSUED 01/20/2006 02/17/2006 3804 07/24 'c716 TOTAL 1.50.22 1,550.72 05/24/2006 11:01 AM $58.00 Printed: 05 -24 -2006 Payee: STEVEN H. AUTIO ACCOUNT ITEM LIST: Description City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 MECHANICAL - NONRES RECEIPT Parcel No.: 1023049069 Permit Number: M06 -009 Address: 3355 S 120 PL TUKW Status: ISSUED Suite No: Applied Date: 01/20/2006 Applicant: WASHINGTON MUTUAL Issue Date: 02/17/2006 Receipt No.: R06 -00639 Payment Amount: 957.00 Initials: 3EM Payment Date: 05/09/2006 04:14 PM User ID• 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 10419 957.00 Account Code Current Pmts 000/322.100 957.00 Total: 957.00 5296 05/10 9710 TOTAL 957.00 doe: Receipt Printed: 05-09 -2006 Payee: STEVEN H. AUTO ACCOUNT ITEM LIST: Description City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 MECHANICAL - NONRES RECEIPT Parcel No.: 1023049069 Permit Number: M06 -009 Address: 3355 S 120 PL TUKW Status: ISSUED Suite No: Applied Date: 01/20/2006 Applicant: WASHINGTON MUTUAL Issue Date: 02/17/2006 Receipt No.: R06 -00578 Payment Amount: 812.00 Initials: ]EM Payment Date: 04/27/2006 01:52 PM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 10414 812.00 Account Code Current Pmts 000/322.100 812.00 Total: 812.00 4917 04/27 9716 TOTAL 812.00 doc: Receipt Printed: 04 -27 -2006 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Applicant: WASHINGTON MUTUAL TRANSACTION LIST: Type Method Description Amount ACCOUNT ITEM LIST: Description Current Pmts MECHANICAL - NONRES RECEIPT Receipt No.: R06 -00228 Payment Amount: 3,787.61 Initials: JEM Payment Date: 02/17/2006 08:48 AM User ID: 1165 Balance: $0.00 Payee: UNIVERSITY MECHANICAL CONTRACTORS, INC. Payment Check 249228 3,787.61 Account Code 000/322.100 3,787.61 Permit Number M06 -009 Status: APPROVED Applied Date: 01/20/2006 Issue Date: Total: 3,787.61 2625 02/17 9716 TOTAL 3787.61 doc: Receipt Printed: 02 -17 -2006 Parcel No.: Address: Suite No: Applicant: Receipt No.: R06 -00086 Initials: User ID: Payee: ACCOUNT ITEM LIST: Description City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 1023049069 3355 S 120 PL TUKW WASHINGTON MUTUAL 3E14 1165 TRANSACTION LIST: Type Method UNIVERSITY MECHANICAL CONTRACTORS, INC. Payment Check PLAN CHECK - NONRES Description 248740 Account Code 000/345.830 RECEIPT Permit Number: Status: Applied Date: Issue Date: M06 -009 PENDING 01/20/2006 Payment Amount: 924.90 Payment Date: 01/20/2006 03:32 PM Balance: ;3,729.61 Amount 924.90 Current Pmts 924.90 Total: 924.90 1525 01124 9716 TOTAL 924.90 doc: Receipt -- - - Printed: 01 -20 -2006 Projec[ t l i /` /` / Type of Inspecti ! � :e( \ t Address: �) 33 v /y f ate Called. C_ Specia nstru s: • ( � Date Wanted: 2 777 / 9 �/y�'I ..."• Request Er: Phone No: �/ �/ / 2 - - 7,7- a/9 INSPEC IT ON NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: INSPECTION RECORD Retain a copy with permit (2 r 6)431.367(0 El Corrections required prior to approval. fr. Inspector: Date /? , ❑ $58.OD FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: intojYt Project: / 4 C / (/tte, / Type of \, /*t 1C » 1406i.1 Address: 15 S3` Si /2.° Al Date Called: Special Instructions: Date Wanted: / Requester: Phone No Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PE )431 -36 ' Corrections required prior to approval. COMMENTS: $58:DQ FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. (Receipt No.: !Date: Project Type of Inection: Add 3 35 . 5 3i ) P/ Date Called: Special Instructions: „• Date Wanted: — J 5 --a‘• / 4trtm p' TTCC Requester: PhoneEAla INSPERIOt NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. Ei Corrections required prior to approval. COMMENTS: p 61 �I / 2 Aif 1% -- Zs %'ti //— S t 8.00 REINSPECTION E REQUIRED •or to inspection, fee must be id at 630dSouthcenter Blvd., Suit 100. Call to sechedule reinspection. Receipt No.: 'Date: Project: 7 L A ` / WC/ G � / �1q Type of IfIrI eeccttion: .i Addre I `70 / GV Date Called: Special Instructions: T rY 5n S tic, 4. !, / _ _ , ,,! . /G f inn s _ Date Wanted., a / - "9- Requester: /� �/. P7 Phone No. g�'GGr 2024 M /Z-7/3 /C/ Y� Wi./ INSPEC ION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ' (2 El Approved per applicable codes. PERMIT N0. 431 -3670 I Jtl Corrections required prior to approval:" COMMENTS: ": . alih 441/44179,-.2 , 154217, iz ' O t GhA7t& COQ �i f - '4" corn. e . • � 1 0 $5$.06 REINSPECTION PEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: 'Date: Project: Type of Ins • ection: Address: oxes, • Sr Date Called: Special nstructions: Date Wanted:__ / ca.m� ��m. Requester: Phone No: 2-o6 X1/7. -43/Y INSPECTION NO. INSPECTION RECORD Retain a copy with permit tijels r ear PERM .." CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431.36 *Approved per applicable codes. jl Corrections required prior to approval. a t ( / � ' e .. 7:- - rc A 6 -e .0-1—c f FSO k nct, —i - c )C / ci —.In s58.otRlF NSPECTION l(E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter BISd., Suite 100. Call to sechedule reinspection. Receipt No.: 'Date: Project: . C< rns/ /rn' 701.2 Min M t: Type of Inspection. R e,v - / A, Address: ??55 S /AO PL- Date Called: Special Instructions: Date Wanted: hl _ d p.m. Requester: Phone No: 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. COMMENTS: J .91 1� 5,. 02t (dr f ib!( 2`4 / Ili �4 . /LL $58.0 rEINSPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. (Receipt No.: 'Date: PER (206)431 -367 MAYES TESTING ENGINEERS, INC. MTE No.: Project: Address: Permit No.: Bldg Dept.: Owner: Architect: Engineer: Contractor: Page 1 Date: Weather: Inspection: Sample(s): E6304 SABEY DATA CENTER RETURN FAN 3355 S 120th Place, Tukwila, WA (onsite) — PIO6009 City of Tukwila University Mechanical Contractors, Inc. University Mechanical Contractors, Inc. 7126106 Inside Expansion Bolts N/A REVIEWED BY: e thy G. Beckerle, P.E. RECEIVED CJAN 2 6 2007 COMMUMTT INSPECTOR: Yavita K. cc: Max Harsliman, Rick Wiseman — University Mechanical Contractors, Inc.; Bldg Dept — City of Tukwila Everett Office 917-134th Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253 584 3720 fax 253.584.3707 Portland Office 7911 NE 33rd DrNe Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 Performed the embedment verification to the W diameter Hilti KWIK Bolt 3, which were used for the Simpson Strong LTT20 strap installation on the 5 Sound Trap support, as detailed in the submitted Engineers Northwest drawings, dated 5/25/06. The installed anchor bolts, do show adequate embedment into the existing concrete floor and to the manufacturer's instruction. Engineer of Record to review for approval. To the best of our knowledge, items inspected today are in conformance with approved plans and specifications. MAYES TESTING ENGINEERS, INC. MTE No.: Project: Address: Permit No.: Bldg Dept.: Owner: Architect: Engineer. Contractor: Page 2 Date: Weather: Inspection: Sample(s): REVIEWED BY: E6304 SABEY DATA CENTER RETURN FAN 3355 S 120th Place, Tukwila, WA (onsite) — T Od oO q City of Tukwila University Mechanical Contractors, Inc. University Mechanical Contractors, Inc. 7124106 Clear Expansion bolts N/A Arrived onsite and found out that the contractor wanted a pull test or tension test on wedge anchor supporting Simpson straps supporting frame work for ventilation fans. I was originally sent there to watch installation of anchor bolts, but that had already been completed. Waited to try to see if equipment was available for the pull test. Also got job foreman in touch with our special projects man, Stuart Carter. To the best of our knowledge, items inspected this date are in accordance with approved plans and specifications. INSPECTOR: Clyde Anderson Timot y G. Beckerle, P.E. cc: Max Hershman, Rick Wiseman — University Mechanical Contractors, Inc.; Bldg Dept — City of Tukwila Everett Office 917.134th Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 tax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503281.7515 fax 501281.7579 MAYES TESTING ENGINEERS, INC. September 20, 2006 September 20, 2006 Revised City of Tukwila Building Department 6200 South Center Blvd Tukwila, WA 98188 -8188 Attn.: Building Official Re: Sabey Data Center Return Fan 3355 South 120 Place Tukwila, WA MTE Project No. E6304 Gentlemen, This is to inform you that registered special inspections have been completed for this project as per our reports, copies of which have been sent to you. Special inspection was provided for: Expansion Anchors To the best of our knowledge, all work inspected was either performed in accordance with, or corrected to conform to, the city approved drawings, or engineer approved changes. We trust that this provides you with the information which you require. Should you have any questions give us a call. Sincerely, MAYES TESTING ENGINEERS, INC. Timothy G ckerle, P.E. Branch Manager TGB:rsm FINAL LETTER Permit # M06009 cc: Torn Parker — University Mechanical Contractors, Inc. RECEIVED 'SEP 21 2006 D EVELOPMENT Everett Office 917 -134th Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253 584 3720 fax 253 584 3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 MAYES TESTING ENGINEERS, INC. p September 11, 2006 City of Tukwila Building Department 6200 South Center Blvd Tukwila, WA 98188 -8188 Attn.: Building Official Re: Sabey Data Center Return Fan 3355 South 120 Place Tukwila, WA MTE Project No. E6304 Gentlemen, This is to inform you that registered special inspections have been completed for this project as per our reports, copies of which have been sent to you. Special inspection was provided for: Expansion Anchors To the best of our knowledge, all work inspected was either performed in accordance with, or corrected to conform to, the city approved drawings, or engineer approved changes. We trust that this provides you with the information which you require. Should you have any questions give us a call. Sincerely, MAYESJE ENGINEERS, INC. Timothy G CBh Timothy G ckerle, P.E. Branch Manager TGB:rsm FINAL LETTER Permit # Onsite cc: Rick Wiseman — University Mechanical Contractors, Inc. t CE:7 SEP 13 200 W COMMUNITY DEVELOPMENT mdrool Everett Office 917 -134th Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253 584 3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 Ken Nelsen - RE: Non combustible material ruling Pa • e 1 From: Ken Nelsen To: Max Harshman Date: 7/10/06 4:12PM Subject: RE: Non combustible material ruling Looks good to us. Appears to comply with IBC Section 602. Ken »> "Max Harshman" <maxharshman @umci.com> 07/10/06 04:O6PM »> Ken, The Mechanical permit number for this inquiry is M06 -009. Max From: Max Harshman Sent: Wednesday, July 05, 2006 4:35 PM To: 'knelsen(rDci.tukwila.wa.us' Cc: Tom Boysen; Rick Wiseman autio(ehswcc.com Subject: Non combustible material ruling Ken, Here is the technical data for the fire retardant wood we plan to use in a return air plenum. The smoke and flame spread index (paragraph 5) meets the code minimum and is tested in accordance with ASTM E 84. Please reply with confirmation that product is acceptable as a non combustible material. Let me know if you have any questions. Thx Max Max Harshman, P.E. Lead Engineer University Mechanical Contractors, Inc. We Build Value 11611 49th Place West Mukilteo, Washington 98275 -4255 (206) 364 -9900 (main) (206) 368 -6242 (direct) (206) 660 -2490 (mobile) (206) 365 -1580 (main fax) www.umci.com Dricon Fire Retardant Treated Wood - 1 -866- USE -FRTW - Fire Per... You r:= =G =u1d'e,fo F ;ire "R ar -dan'f r eatie a o'8' Introduction Product Specifics Properties Model Spec Warranties Standards & Building Codes Resources What's New Other Arch Products Search Home Fire Performance - Flamespread & Smoke Developed Values - Tests - Fire Resistance > Hourly Ratings > One Hour Wood Truss Assemblies Flame Spread & Smoke Developed Values Dricon FRT wood has been tested for fire performance by several independent laboratories and meets model code requirements. As a result of tunnel testing at Underwriters Laboratories (UL 723, ASTM E 84, and NFPA 255 are essentially Identical) an FR -S surface burning characteristic classification has been assigned to all softwood species of Dricon FRT wood, The tunnel test compares surface burning characteristics of tested materials to those of asbestos cement board and untreated red oak lumber. A rating of 0 is assigned to asbestos cement board and a rating of 100 is assigned to untreated red oak flooring. Flamespread ratings of various species of untreated lumber range from 60 to 230. A rating of 25 qualifies for Class 1 /Class A requirements. During this test, smoke emissions are also measured and ratings are assigned on the same scale. These Flamespread and smoke development ratings are established during the first 10 minutes. However, unlike for fire retardant coatings, building codes require that the test be extended from 10 minutes to 30 minutes and the flamespread not progress more than 10 1/2 feet beyond the burners and show no evidence of progressive combustion. Dricon FRT wood has a Flamespread and smoke developed index of 25 or less when tested in the E -84 tunnel test and shows no evidence of progressive combustion in 30 minutes. Dricon treatment reduces the flamespread of most species to less than 15 which is essentially the same as gypsum wallboard, Standard tests for surface burning characteristics of materials referenced in the model codes as a basis of acceptance of fire retardant treated wood are all essentially the same. Surface Burning Characteristics htt p:// www. dricon .com/fireperformance.shtml I of 3 6/22/2006 12:17 PM WoodTmisd Wet wet Dricon Fire Retardant Treated Wood - 1- 866 - USE -FRTW - Fire Per... • UL 723 - Standard Test Method for Surface Burning Characteristics of Building Materials was developed by Underwriters Laboratories Inc. and subsequently adopted by ASTM as Standard E 84. Tests Smoke Flamespread Development • ASTM E 84- Standard Test Method for Surface Burning Characteristics of Building Materials Is essentially the same as UL 723. It also has been adopted by ANSI. • NFPA 255- Method of Test for Surface Burning Characteristics of Building Materials is essentially the same as UL 723 and ASTM E 84. • UBC Standard 8 -1 Test Method for Surface- Burning Characteristics of Building Materials is based on Standard Test Method ASTM E 84. Factory Mutual Research has also evaluated Dricon FRT wood and found that it meets the requirements for a Class 1 Impregnated lumber deck. The ASTM E 162 radiant panel test and NFPA 258 smoke density test have been conducted by the Hardwood Plywood Manufacturers Association and have demonstrated the acceptability of Dricon FRT wood under Department of Transportation regulations for use In mass transit vehicles. Dricon FRT wood has been tested in accordance with the following procedures: • ASTM D 1413 • ASTM D 3201 • ASTM D 3345 • ASTM D 5516 • ASTM D 5664 • ASTM E 72 • ASTM E 84 • ASTM E 162 Fire Resistance http://www.dricon.comifireperformance.shtml • Boeing BSS 7239 • MIL -L -19140 • NFPA 255 • NFPA 258 • NFPA 259 • UL 723 Hourly Ratings Fire retardant treated wood has a surface burning classification and, by itself, does not have a resistance rating in hours any greater than untreated wood. Fire ratings in hours are assigned to door, wall, or deck assemblies following testing In accordance with ASTM E 119 and E 136. The references such as the Underwriter Laboratories "Fire Resistance Directory" specifically points out that FRT wood may be substituted for untreated wood in any related assembly. Dricon FRT wood can be used as a component of such assemblies In structures where the code does not permit the use of untreated wood. Descriptions of fire resistance rated assemblies incorporating structural lumber are listed in several publications, with the following being those generally referenced in model building codes: • Fire Resistance Directory, published by STET • Fire Resistance Ratings, published by Engineering and Safety Service of the American Insurance Service Group • Fire Resistance Design Manual, published by the Gypsum Association 2 of 3 6/22/2006 12:17 PM Dricon Eire Retardant Treated Wood - 1- 866- USE -FRTW - Fire Per... • • Uniform Building Code, Including a listing of fire resistance rated assemblies For example, the Gypsum Association's "Fire Resistance Design Manual" shows a one hour wall or partition assembly (WP 3605) that has wood studs covered by 5/8" Type X gypsum board with specified nailing and positioning of the panels. This assembly could be used for interior, non - bearing partitions, requiring a one hour rating in a noncombustible structure if the studs were Dricon FRT wood. In a similar manner, by substituting Dricon FRT wood for untreated wood, other one and two hour wall and ceiling assemblies can be used in noncombustible type buildings. The model codes also permit use of ceiling assemblies with the top membrane omitted where only unused attic space Is above. Some model codes and local building officials will accept the Component Additive Method (CAM) for calculating fire resistance In lieu of actual assembly testing. The CAM concept entails adding the resistance rating of individual components to qualify the resistance rating of the assembly. The lumber and plywood used In rated assemblies or CAM listings are usually not Identified as being untreated or FRT wood, but the model codes generally do require that any wood used In noncombustible types of construction be fire retardant treated. Also, due to wood's natural ability to Insulate, wood may be more acceptable than unprotected steel In fire resistant assemblies. For more Information on CAM, see the American Wood Council web site at www.awc.org /Publ ications /dca /dca4 /DCA4.pdf or contact Arch Wood Protection. One Hour Wood Truss Assemblies Arch Wood Protection, Inc. Copyright © 2004 -2006. All rights reserved. http://www.dricon.com/ftreperformance.shtml Recent testing has provided effective and competitive designs for one hour rated floor /ceiling and roof /ceiling metal plate connected wood trusses. Unlike earlier designs, the one hour rating can now be achieved with only one layer of 5/8" Type X gypsum wallboard applied directly to the bottom chord of the truss. Dricon FRT wood can be used In place of untreated wood In many of these designs and will enable the use of these assemblies in many building construction types that do not permit untreated wood. These new construction assemblies provide greater savings than ever before when Dricon wood construction is substituting for hourly rated steel or concrete construction. Home 3 of 3 6/22/2006 12:17 PM Howard S. Wright Construction Co. 501 Eastlake Avenue E, Suite 100 (98109-5451) PO Box 3764, Seattle, WA 98124 -2264 USA 206 - 447 -7654 phone 206 - 447 -7727 fax www. howardswright. co City of Tukwila Department of Community Development Bob Benedict, On May 6, 2006, Cochran Electric and Howard S. Wright Construction Co attempted to conduct an EPO test for Washington Mutual Bank at the Sabey Data Center located at 3355 S. 120 place. During the course of the test, one of the Power Modules experienced a failure in a circuit board and the test had to be aborted to prevent loss of technology that was being powered by that particular unit. We have re- scheduled the test to be conducted on Saturday night, May 20, 2006 starting at 11:00 PM. We feel we will be able to complete the test in an 8 hour period barring any more problems with hardware. This work is covered under the Mechanical Permit # M06 -009. Thank you for your consideration with this matter. Sincerely, Steven Autio Project Superintendent Howard S. Wright Construction Co E -mail. autio@hswcc.com Phone: 206-812-1314 Cell Phone: 206 - 612 -9572 May 8, 2006 o<l de r a tee y ra seattle portland • sacramento • san Francisco los angeles • phoenix RECEIVED CITY OF TUKWILA MAY 0 8 2006 PERMIT CENTER ACCOUNT ITEM UST: Description City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1023049069 Permit Number: M06-009 Address: 3355 S 120 PL TUKW Status: ISSUED Suite No: Applied Date: 01/20/2006 Applicant: WASHINGTON MUTUAL Issue Date: 02/17/2006 Receipt No.: R06 -00639 Payment Amount: 957.00 Initials: 7EM Payment Date: 05/09/2006 04:14 PM User ID: 1165 Balance: $0.00 Payee: STEVEN H. AUTIO TRANSACTION UST: Type Method Description Payment Check 10419 957.00 MECHANICAL - NONRES RECEIPT Amount Account Code Current Pmts 000/322.100 957.00 Total: 957.00 doc: Receipt Printed: 05-09-2006 ,, PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M06 -009 PROJECT NAME WASHINGTON MUTUAL SITE ADDRESS: 3355 S 120 PL Original Plan Submittal Response to Correction Letter # DATE: 05 -17 -06 Response to Incomplete Letter # X Revision # 3 After Permit Issued DEPARTMENTS: n B uildi g Division Public Works Complete Comments: Documenls/rouring slip.doc 2 -28-02 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) APPROVALS CORRECTIONS: Fire Prevention Structural Incomplete ❑ DUE DATE: 05-18-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU NG: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 06-15-06 Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Planning Division Permit Coordinator Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M06 -009 DATE: 04 -24 -06 PROJECT NAME: WASHINGTON MUTUAL SITE ADDRESS: 355 S 120 PL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 2 After Permit Issued DEPARTMENTS Bull in -- n Public Works b PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ' 4r Fire 1 11 revention -2 Structural DETERMINATIQN OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS 0 Documents/routing slip.doc 2 -2602 /CORRECTIONS: Incomplete TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: DATE: Planning Division ❑ Permit Coordinator ❑ DUE DATE: 04-25-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 05 -23 -06 Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: t4o-O 1 Bull ng Public Works Complete Comments: Approved Notation: Documents/routing slip.doc 2 -28 -02 APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: si PERMIT COORD COPY, . PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M06 -009 DATE: 02 -07 -06 PROJECT NAME: WASHINGTON MUTUAL SITE ADDRESS: 3355 S 120 PL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 After Permit Issued El 91 4 V1-09 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Approved with Conditions Planning Division ❑ Permit Coordinator ❑ DUE DATE: 02 -09 -06 Not Applicable ❑ ❑ No further Review Required DATE: DUE DATE: 03-09-06 Not Approved (attach comments) ❑ DATE: u Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: F il�����` t' B Division Public Works ❑ Complete Comments: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 338-02 tom PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M06 -009 DATE: 01 -20 -06 PROJECT NAME: WASHINGTON MUTUAL SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued a ' 5q Fire Prevention Structural DETERMINATIQN OF COMPLETENESS: (Tues., Thurs.) Incomplete TUES/THURS ROL TING: Please Route Structural Review Required REVIEWER'S INITIALS: Approved with Conditions ❑ Permit Coordinator ❑ DUE DATE: 01 -24-06 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required DATE: DUE DATE: 02-21 -06 Not Approved (attach comments) ❑ DATE: Planning Division Not Applicable ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Revision No. Date Received I Staff Initials Date I Issued Staff I Initials , Summary of Revision: 2 ( Iil Received By: Revision No. Date Received I Staff Initials I Staff Initials Date Issued Staff Initials 2 ( Iil • it. Received By: I c rrcr_Itirt Received By: 'Mr Pmrke*-- ` i�' Is Summary of Revision: ) s i 1 ) is, ►9 �� I � � os- D`l L t."1•faJ�rl'luim rt5m VIM Irk 'IS Received By: ��.• I Revision No. Date Received I Staff Initials I Date Issued I Staff Initials I OS Imo• Ote 1 ° 1 rE1144 taff ! Summary of Revision: in4- (I (so (P -hA t (►n -tnc, at, d °et7W1•i A4ctvIv(i4 < Received By: -{ OOhAvol � lit(IAi Ift_ p c rrcr_Itirt Received By: 'Mr Pmrke*-- Revision No. Date Received Staff i Date I Initials j Issued I Staff Initials I 02• cr - •cAo Mr ! Of- 11- ru Summary of Revision: Summary of Revision: ' Ih(NJG1S( S!'ro Received By: Received By: ix, Revision No. I Date Received I Staff Initials I Date Staff Issued i Initials I Summary of Revision: Received By: PROJECT NAME: Site Address: PERM: NO:. AAao- Qa 120 PI — OriginSVIssue Date: REVISION LOG (please print) (please print) ' (please print) pt ease print (please print) Date: 5-11 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: hap: / /www.ci.tukwila.wa.us Steven M. Mullet, Mayor Plan Check/Permit Number: r l Ott 0 Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # 3 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner erry MAY 17 2006 WIT CENTER Project Name: SA I3 EV Phase 2 (W nuismti .Mvrxu) Project Address: Ir) if5- ( d Fast Camp lets 1 iass $ . /?Oth PL •Tukwlla 9ig 1i� Contact Person: Mme HeA rS h man Phone Number: ZO(o 3(oR - l0142- Summary of Revision: I n sta l I (SO) 120 fans and ' `I And &1-k n u D nrS i o n { i (ou i l di n5 pitSSIm Vftt-litirtmot,1 j 4lko ,2 4 g . CO Sheet Number(s): M n. t H 2 2A M3. I "Cloud" or highlight all areas of revision inclu date 0)revision p Received at the City of Tukwila Permit Center by: ( I A ✓ IA,Q� Entered in Permits Plus on CS "(*I (if !applications\ ones- applications on linarevision submittal Created: 8 -13 -2004 Revised: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.cttukwrla.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: I+ 14-o& ❑ Response to Incomplete Letter # _ ❑ Response to Correction Letter # Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner t b 5D % ChfiA4 tot Sheet Number(s): Iv l k • 0 $ M 2 • ZA "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: t iti Entered in Permits Plus on t - 24-0 to \applicadonsWorms- app lmations on line4evrsron submittal Created: 8 -13 -2004 Revised: Plan Check/Permit Number: M D(I - 00g Project Name: C!S 'f0✓1 MV Gu )cs� � ,2-c ivv lJ Y/� • 1:10C/2- Project Address: 355 S- fvt P(a c. � Contact Person: Max karski la.c/1 Phone Number: Z0 Co 'Rob • (o2-L1 Z Summary of Revision: el/blila-P . Ot/lk (I) V HV &,X - v t l - (3) -Fl y.-/ 3 4oKe Dam rs i a vDol O (2) AC -b nc i s - h ( crs - 5ccee DC wort-is a d fi ovto} weft- 3° nefA fray/It) r M,t_ol oA ea s � "� TUKWILA APR 2 , 21111 "7 Mme• a 61A -n(4 Date: Gi• ° Sheet Number(s): Mt' it City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: M O (0 '001 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # _ Revision # ( after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Lon Si/14In9 /) IUMVOU SKGt tie . 20 10vio,( pCat( O EiC%2 Project Address: 33 S5 S• I 20 4 PI • �'�L Contact Person: MA)c Hd t bffiftf/1 Phone Number: 7o c , - t AIL( 91 d Summary of Revision: AdOtAV Ourn 4 Or I1Iry Per -{- Plcw15 erz de si CA/1oA S- "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ` hL'tiu.c q1 Entered in Permits Plus on �" - O�p \apptications\forms- applications on line submittal Created: 8 - - 2004 Revised: Steven M. Mullet, Mayor Steve Lancaster, Director RECEIVED FEB 0 r zoo6 k'iRMtTCENTER License Information License UNIVMC *343N9 Licensee Name UNIV MECHANCL CONTRS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 578025176 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 11611 49TH PL W Address 2 City MUKILTEO County SNOHOMISH State WA Zip 982754255 Phone 2063649900 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/29/1966 Expiration Date 10/3/2006 Suspend Date Separation Date Parent Company Previous License Next License GRANSML9B2R3 Associated License Business Owner Information Name Role Effective Date Expiration Date BUSH, GERALD D PRESIDENT 03/13/2002 GRANSTON, EDWARD B SECRETARY 03/13/2002 PETTERSON, DEAN M TREASURER 03/13/2002 SMITH, DOUG VICE PRESIDENT 03/18/2002 KOMMERS, EDWARD D VICE PRESIDENT 03/13/2002 09/13/2004 VICE Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 4 laws tar Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https:// fortress. wa. gov /Ini/bbip /printer.aspx ?License= UNIVMC *343N9 02/17/2006 1 v 0 :1 CM w ow gQOeor° § @i pilaw e11„ pulp 1 I I iII �� � i Rill 1 i ; I I 44 FHH'WOH""'M ;!!!! 1111 • sr 3 'zits] gi II 0584 f"101 mm 1 m; 0 <ori f l . � ± �!llT m!T��� 11 °a0 g I � ° a$ Eilama entO k 4tti;L:4 1 1 1 gag vi rgiggff Aasie rUgly Intl. MECHANICAL SYMBOLS AND ABBREVIATIONS III UNIVERSITY MECHANICAL CONTRACTORS, INC. we Build Value t.JIAM Q" I f J J 1 8 will 1 4.4% mind= L00m M dItIQ, P _ Phonr {Z 364 -9100 6 Fc� `�vo) 301 -2124 m 11 MI H i 1 3 0 IA 1 1 H 766 01HHOH00 5 1 A 1 e r f f isLiiL0F1 s 2129 IQ° wili111111 ig" ”IV 8 4P3ir 0 IONR i §ill PV 4 2a arilaa Mpg '911, 1121 114 11111 11 11 Olin; 11 ol s 11 '. hLAve • 2811•Ave..t co i a N ao.p m .. .gym. , a . Legal Twe DRAWING AND THE RJR NI1REW ARE THE PROPERTY OP UNIVERSITY 1411014ANIOAL CONTRACTORS, 110. FOR TIM USE IN CONSTRUCTION OF 7148 PROJECT. NO OnE a USE UNALL EE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY M OCHANICAL CONTRACTORS& 110. Zth- Ave:.:... 1 � 2 Wig A gill 1 i i "� ' I • ... ...qah- 'Ave :•s , Project/Owner Information 1 1 WASHINGTON MUTUAL SEATTLE REGIONAL DATA CENTER EDC2 Project Address: INTERGRATED EAST CAMPUS 866 8. 120TH PL TUKWILLA, WA 98168 Owner :WASHINGTON MUTUAL 1111 3RD AVE SEATTLE, WA 98101 A HP 1 IMMIPPIPP ei hi A B �� !I i r 14 mos rrimi 1 v H 1:ii, 6!! 9 I i I iiI I I 2 Ism: PERMIT / CONSTRUCTION DOCUMENTS Rev. flew. c m zg92§Pa§a" 4RWW9911P tN 1 z a 0 C m a rn rnmr" o P .4 p, ¢n : • !•• N :91 I qI4 0;11Wiileir 8 1 ; 11 I m° ON Illml g m A 151 P gPi z r 1 • e • IV. 4111111' 11 HIM! 1 i I 4 “• goo 21 Title ra —0101iolisigH d 1 1.4 T i 1 -1 i.. t.� � �11J T!TT!T!TTT 11 A I g 11 i9 6 )EiletiHiaza e i1L + 1O I 114 44 1 : k: anal mmininti 1 1 1 r UNIVERSITY MECHANICAL CONTRACTORS, INC. We BulWd Value 1 1 wIliggeo peeoptillipg118 11191' N'Wn ere' g 6i6 90l 448 1 wa 111P 11 ;1 I I I " 1/41111 P lig "Pi 1 A 1 1 1 NI 1 1 1 I — 9 FHHeHiOviweT I 1 1 1 1 1 1 H ' 1 11 WI 1 1 11 filo lift; ;1 %I a uN wQ .4§ a zg -0 4,1 EJ/4 _....„,_,Fri MECHANICAL SYMBOLS AND ABBREVIATIONS amiggigom t t61 t 4olh WasRno W Pnone: � 3 ae� -moo AIuWIlso, h 476 Fox: 361 -2126 SM MP Ilf 1 1 11 IL r t 1 § i NI HI 1 ili S2Rig 1$1 1111i:g !m 1 s 9mar §8R@ MN 11111 RSV' 4 ma AINAIsg= mil! 19:111 !!!! 111111: !I!! i 1: !1:111111 Legal THIS CRAMS NO THE MOON MEIN UNIVERSITY PROPERTY o� CONTRACTORS, N0. FOR THEIR USE N CONSTRUCTION OF THIS PROJECT, NO OTt#R USE SHALL ON PERMITTED YRTHOUT THE WRITTEN CONSENT OF 1SNVERSITY MECHANICAL CONTRACTORS, INC. Project/Owner Information SABEY A -0 1 1 Project Address: INTERGRATED EAST CAMPUS 366 8. 120TH PL TUKWLLA, WA 98168 Owner:WASHINGTON MUTUAL 1111 3RD AVE SEATTLE, WA 98101 3 1 1 1 A � A Nirl PPM !Pr goo 16 gill: 1 1° 11 Phir IR Eig eV an 11 !I al O r p I r g r K � b !b :Ol 11 1: is p g igoig cl- ! d rib 011 I Eli 5 41 € If 1111114 8 6 4 II f 01 1 11%ill r I 1 u F A a s I C I 8 I!! N t 1 1 1 1 011 1 11 1 11 11 11911 11; 11 Ell mm 1 :ewe: PERMIT DRAWINGS 3 Q pr WI : fo• 11 1 g m .1; Ri 1; I i A il rrl 5/15/06 r J 4 • • 1 era r UNIVERSITY MECHANICAL CONTRACTORS, INC. we Build Value SECOND FLOOR RAISED FLOOR HVAC PLAN - PHASE 2 Legal THIS DRAMS AND THE OMEN HERRN AM THE PROPERTY OF UNIVERSITY CON RS INC, FOR THUP USE N CONSTRUCTION OP THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN coma OF UNIVERSITY 11ECHANIOAL CONTRACTORS, NC. • 1 . CI . 1�.:..._. .. ... . Project /Owner Information • a: ■ WASHINGTON MUTUAL SEATTLE REGIONAL DATA CENTER EDC2 Project Address: INTERGRATED EAST CAMPUS 966 8. 120TH PL TUKWILLA, WA 98168 Owner :WASHINGTON MUTUAL 1111 8RD AVE SEATTLE, WA 98101 7.7 : _74t77r.V.1:ti;y-i!_1 a 1 ...... .... . ..;. I..._... .:....� • $,2 GYM b...0 .. ivt2 1 Sage _ /=1' 1 I Job Na 4104 1 . I OW1 Ime Ikle 5/12/06 I - gy m.. URN I fts It; 419 Y Jaz ,, 110 7;4‘1\ WNW ao1 T1tIe SECOND FLOOR HVAC PLAN — PHASE 2 Project/Owner Information Issue: PERMIT DRAWINGS 6/16/08 SIVI VCAL, m UNIVERSITY MECHANICAL CONTRACTORS, INC. COHT 384 -9900 381 -2 Legal a,,,,,, AND ,,�,,, "ER°'I ARE 1 Y UNIVIERSITY PROPY OR C ONTRACTORS FOR T aT TM ea WITHOUT TFe war= wow OP utavenerrY MECHANICAL CONTRACTOR& NO. SABEY Project Address: INTERGRATED EAST CAMPUS 355 8. 120TH PL TUKWILLA, WA 98188 Owner•WASHINGTON MUTUAL 1111 3RD AVE SEATTLE, WA 98101 Bo. AL �` D 0 0 We Build Value 11811 49th Plop %A. Phone 208 Muldlteo, Washington 90275 Fax (208; 0 • • e I • • f , 1 1 1 • • 1 N 1 1 1 1 1. 1 IM1tlBA18bN1tlbPlggMbU lliIllIllIllIllillIl 11111111111111111111 IIIIuhIuh11IIIflhI SilliiiialallialaSii CCCCCCCCCCCCCCCCCCCC alallaaaaaaaaaaaaaaa UUitM111111 ; M$UUM 11111111111111111111 11111111111111111111 It CMCCCri ViAVVVCCCCCMC'CC I I I I I I I I I I I I I I I I I I I I W W W 4 W WW M W M W M W W W W W W IA W t141114 41:1 000“..00fOgi Offff0f0 1 IN CICIttlq • • W W W la 4 PO r N.r 1+Ir uwWw.M 8 arias& tais a vial, • •1, 3 *i'2 aa.a'a &'18:13 4 4'44 1 • 1 4.4'4 XiWV a;aaa 3A 1Aaa aaaa *111 WIC n n n'n NISI MM 1 1 1 MrilIMIMMIlirrabrommft L!1 V JT 4 ' • [7777.77 0. L n • 9 • 9 N r•, 1' 1 • CJ nil i r Dj - L ;. • • Il i r^� r 111 1 E NUM no no rib 4D CI 1 . \ % . 1 1/411 . 11 .ttlslx. 111 !I :1 „gift, 0 • • IV ru ridNi 1 :... r ▪ i ./ 9• • 1•• r .+. . W . ;1 • 1: • • • Jr ' i i. . r —4 r.: I .. �. • A J.1 ' r i r te .. .... 1 1• .. i 'Jr 1.1 1 1. 1 1 t i .ti V;: 1 a e1 '1 n NM ro A CI fV 2 It 2 1 1 1 8 1 1 1 11 1 1 1 U UNIVERSITY MECHANICAL CONTRACTORS, INC. we 9uIId Velue • __ ._a••.•••1+• . • • . • • • . . • • 111 1.1 rtle THIRD FLOOR HVAC PLAN -- PHASE 2 • . ,. .. .,, .. 1 ' ... to • , • 1 .1 • 1 1 . . • .i. • t • i.• • • • I • • .• , , I •, • .. • , 1• , • • I. • • 1 • •• • 1. •. 1 ' :1 • I 1 .1 • ! 1 1 1 .1- 1• • • • I ' •b • 1 .•il . • 1 , ; • r is • ; •"' • • 1 . • 1 • i • •! I 1 4 • 1 • 11 • • -' 1 ! 1 , • 1..•• ... ' • .•.....•...1• • 1 I 1 �... ...... . ..1; n .. . • . • • • • ft I• l i .. .. . • ; 1 % '.•••• • ; 1 ,. .. L • Project/Owner Information l ••• . • j • • 1 • .•1" • • • 1•... 1 • i • I ' 1 • • � " • • .0.. r' I•...,.,,.. 1 ..1 • • ..... .... • • 1 I ' , . ,- 1 ....._: ;. . . • .1 ....., ..... • • Legal WASHINGTON MUTUAL TM DRAWN# AND THE DS SN UMV!R IT/ C s SEATTLE REGIONAL DATA CENTER EDC2 CONTRACTORS, Na FOR THEIR PRINICIU81 N CP THIS Pro Addrae: . OTHM>A ust SHAU. IN TERORATEST CAMPUS SS PIRAITTE 0 WITHOUT THE S jec Rat PL EA wRITTON CONSORT OF ISNVITRefTY 11011 49th low Woe. f+ (200) m+.9000 mow n& CONTRAOTORI, NO. TUKWILLA, WA 98188 maul= 1101 bo, Washington Ho VOW 1 - 2120 Owner:WASHINGTON MUTUAL 1111 3RD AVE SEATTLE, WA 98101 t..• .............. . . ... .....•........... j • • • 1 •. • i .. i . • i i . , • 1 • . j 1 • . . .i • .-.:, • '1 . •• ;:•.- • • • 1. • • 1 • • • • I .4 4— • i T N , :••• (t4 s • • �. .. ... • _..._.___.�...— ...... 1 h • 1 . 11 ' • • • 'j ••• . L. ............. .............. • ••'11' . . .1 • • • • - . • .. _.••1 +1 -• .-. • e... 41 • • • I 1', _ •- . .. :T • • 11S• 1 , ,,. • I : . 1 • • • • • • , • -4 Issue: PERMIT / CONSTRUCTION DOCUMENTS 1_• — • '1 ' .f' • • 11 • •• 1 1 •1 1 „.. MI M s 1 Ij a 1 1 le Is 1 fi 1 1 1.• 1 M 1 1 M 1 1 1 1 m 1 1 1 1 1 1 40=116■IMMI• a 1 ■■••••••• - • •••••• •••■•• • • • • lir)! .4 .• ' • ••• • . Iv- • •• • 0.••••••• •••4•••• I' • 'I 1 . . • ..1 I .. I : . . 1 , i • • • • ••• , • .; 4. 44 1 1 I 1 11 I I • 1 • ••4 1j • fr , ••••• •• ••••■•••••••■ •• ••■••• 11 0 1 4M•• • •• ■•••■•••••••••••■• 1 . • 4. 116 • • • 1; I •••• ) • ' **/ • •:••1• . )(,) ;4' - • 1 1 1 • ••••• ■•••••••■•••••••••• ■•••• ••••■•••■•• I ■••••• • •••• ••• ••••••••••■••• •••■•••• •■••••••••40 •• 1 • ; •••• • • * *ON ••■• * cr' 1;01 •••• • • 1) l't 1 1 ■am• 1 •1••• - 7•• , • ••••••■■••11 ■■•••••ra.•••••••••• • ....4.:4.•:•••:•.1..o • 4 . • • r‘ I ot r • 4/4 111 •I• I• • /1 • • oJ I - , :-...: V ... . 1....i.‘.. 11. • 1 .•.„, , 1 , , 1 ••• ... ,; i • i ' " • l'n • 14 • .1 I • 1 . 1 ; I ' 4: 1• 1 • • •-• 11 ' • ' • 11 • • • 4 ' • I ntle FIRST FLOOR HVAC PLAN - PHASE 2 I 41 L: 2 N) 0 • • • ■•••••+:4 1 w LV I UNIVERSITY MECHANICAL CONTRACTORS, INC. We Build Value mingigue 11 4 14 1 st 112 Fax: (2 48 0' 5 el 2 S 6 6) 381-2128 • 1 I • r . •• 1) I .• • • • • ' 41.11111111 / I • 1•••• 0 1: . • I , ( / 1 •1 • 1.:•1 r • •-• „• 6 •■• 1 4 1 MICHANICAL CONTRACTOR% W4 • ■•••••••••••••■ • •• wril••■•■• Legal MS DRAWING AND THE DESIGN I_1 ARE TIM PROPERTY OF UNNERIEW MICHNOCAL CONTRACTORS. 110. FOR MIR USE N CONSTRUCTION OF MIS PROJECT. NO OTIOR USE MALL MI PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY 9.4)(J 1;01) IA C P . 1 . 1 , , ••••. ; . • • 1, ... , .4. -4--- ■• ‘,.......•;••■• _. , ..= 7 / 4 ,././.. I 1 4 .... / ; 11 • • '34 WI • ---• • I It I.6 4 4: . LI/ r:1 to t 4. CO 1 ,• • •I '7' •4; • I ••• 1 . - 11 " 1,1 •• Project/Owner Information 7 0' t 1.// • .7 -1 , 1 _:;71 . • : H- 44. t 4 1 1 ).• 1 1 4 • •:•■• cr) - 31 /I • ..;1=011*••••./.4•40. ••uu *Au**. •••■••...4.0**1•1.**1... frimmol N 1 i • • 1 • •■• [CI •• • / • 1 4 • : • ) ;1 q 11,1 :) • • • 4,0 ; • 4 ..1 • 0 .; .;1 ; • • IT17; : 1 :O.:, 1 " 4/1 • 1: l • •.,I•1 •/ • . Co 1 " r• • ' 1 -,"‘ ...... • • 1 A F ,Z 0 • gm. • 4. ••■• ' WASHINGTON MUTUAL SEATTLE REGIONAL DATA CENTER EDC2 ■•• •••■•••••■11.1 Project Address: dress: EAST CAMPUS 385 8. 120TH PL TUKWILLA, WA 98188 Owner:WASHINGTON MUTUAL 1111 3RD AVE SEATTLE, WA 98101 c. F . .. ,...' ..a....11-r- -. P ..- ...••••••r.- ..... ‘ - ._...._._... 7 , ..„..........*.........„. 4, • • 1/1 0) •• . .• ,:: .. I -':, 2....e .".7'''..--7'"rss' l_ ._. '7 : :-'::':':-F-4c':--a:z3"r" ""'" '' , ':' .' : :1 7 : Li : . ' .. .."' '.7- .: .. ! --s . --.,..:, - ...::. .. : . - ' : - :, <. ...„.. -- 'il ,._....•;.,_ .....••••••■•■•■I• -■••••• .• ... ••••■• ...••••■• * ! JO' • ..., ! ! C - 10 " 0 I ' ''.4 . ...,. ; .. 1 \ ‘ 1 ' "--- . (7 . ' ;•,..• / 1 1 .. • r - .;,. t'l 9 .. • 1 I 0 . c..• x ..•': %_. l'' !`), -7 _-- 1„.7.1._ lc ri :• I Aj • . 1 1 • • • • 1.1 •••••■•••••••• 01••••••■••• - • ' ss,„, r- 7 = 7 .1P.i....4=. • •1• 4 • I 71 7) 1 0 ;0 • ft 1 1 At< • •••• •••• • .■• ■■■■■• .■ • .01. A " 101■110 ..?" . .. • 0 r ' ; HI • -• ••••••■••■•••••■•••••••••••• • • • ■ • IP • ■••• • • ••• 1 q . • -40 • rn co MI • •• ■■■■■■■■■■ rz r• . rn. : ••••• “: ••••••••ft:•••••r a .1•••••■•.-ty...•••■••• issue: PERMIT / CONSTRUCTION DOCUMENTS ,......•••••••••••••••••••••■•••._ il Jr 1•1) 0 7) 7 0 11 / 2 c,_ L.r..__c4.. ( '-'. LI %, t .1 - rYl_ _ L . - i. .. 717 1 - . 2 . 1 . ! •:. , i .1- . .... 1 ..."4 > :1 rn ,111 it - ,_ rtt:; M A ''. 5 S1 • / 3 i • .:' : (.-- ?••.1. : T tt ' - '''''''-. e_- t .„..., .-,, . _ _ .. _ 4; 1 (.1) 1 so 1 i• - - 4 --- .1 1 t..) 1 ) 1 1/ r /- 1. L 1 1. 7 - . . 4. 0••••■•■• •■ • ••• • ..> t1 r'1 4J ••• 1 •■■•••■• co • ••• 111 ••• •••••• O.. • •■• ..•••••■ Ada • • • • • • • 1 1 • • Sow 46. • •1 1 r UNIVERSITY MECHANICAL. CONTRACTORS, INC. Wo wild Volt* • , r 11411 44th PloN Phone; ‘208) 3444900 mijoglaca MuIdltso, Washington 75 fox: 11218 341 -2120 E rnl• ROOF LEVEL HVAC PLAN - PHASE 2 dip • 4 I •'•Y4,: I • • • Legal THIS DRAWING AND THE DIIMON HEREIN AM THE PROPERTY OP UNIVERSITY MECHANOAL CONTRACTORS, Na FOR 11 MR USE N CONSTRUOTION OP THE PROJECT. NO OTHER USE MALL SE PERIATIM wIT'MOUT THE wRITTEN CONSENT OP UNIVERSITY MICHAMOAL CONTRACTOR% INC. t: •r Y. 1 • f• . '; . , '11 LI Project /Owner Information ••, •r , 1 1 :4/ `• ' • 4 ..._... • WASHINGTON MUTUAL SEATTLE REGIONAL DATA CENTER EDC2 Project Address: INTERGRATED EAST CAMPUS 366 8. 120TH PL TUKWILLA, WA 98188 Owner :WASHINGTON MUTUAL 1111 3RD AVE SEATTLE, WA 98101 •1: C • IV. • .•. • 1 ' • 1 •• " . I •• ! . ?` Q ' p • • j Issue: PERMIT / CONSTRUCTION DOCUMENTS Rev Deee. • • J • • • • • • • • • .•; Tltle DETALS AND SECTIONS tip UNIVERSITY MECHANICAL CONTRACTORS, INC. we Build Value 11011 40th. Plooe .IDOwnsfiS1m Muldlleot Washington va: C am ) 3 -�e Legal TIN DRAWING AND THE DESIGN HEREIN UNIVERSITY MECHANICAL oP CONTRACTORS, Na FOR THEM USE N CONSTRUCTION OP TNIS PROJECT. NO OTIER USE SHALL SE PERMITTED WITHOUT Tlls WRITTEN OONSDIT OR UNIVERSITY MECHANICAL CONTRACTORS, NO. SABEY Project/Owner Information d ,r",' -,o• 1 1 } 6 ' -9' 6 ' -2' Project Address: INTERGRATED EAST CAMPUS 855 8. 120TH PL TUKWILLA, WA 98168 Owner:WASHINGTON MUTUAL 1111 3RD AVE SEATTLE, WA 98101 Issue: PERMIT DRAWINGS 5/15/08