Loading...
HomeMy WebLinkAboutPermit M06-011 - ELLIOTT BAY SERVICE TRANSFERELLIOTT BAY SERVICE TRANSFER 349 UPLAND DR M06 -011 Parcel No.: 8836500060 Address: 349 UPLAND DR TUKW Suite No: City & Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ct.tukwila.wa.us Tenant: Name: ELLIOTT BAY SERVICE TRANSFER Address: 349 UPLAND DR, TUKWILA WA Owner: Name: BOEING OREGON MASABI TRUST Address: 1325 4T1-1 AVE SUITE 1940, SEATTLE WA Contact Person: Name: JOHN ANDERSON Address: PO BOX 1108, WOODINVILLE WA Contractor: Name: R MILLER CONSTRUCTION Address: 146 THIRD AVENUE SOUTH, EDMONDS WA Contractor License No: RMILLCI190L5 DESCRIPTION OF WORK: INSTALLATION OF A NEW GAS /ELECTRIC ROOF -TOP UNIT WITH NEW DUCT SYSTEM. Value of Mechanical: $10,000.00 Type of Fire Protection: Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 doc: IMC- Permit MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M06 -011 Phone: Phone: 425 -487 -2359 Phone: 206 583 -0238 Expiration Date:01 /02/2008 Steven M. Mullet, Mayor Steve Lancaster, Director M06 -011 02/06/2006 08/05/2006 Fees Collected: $269.58 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 16 Thermostat 1 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment... 0 Printed: 02 -06 -2006 Permit Center Authorized Signature: a ZeZ-c Q . (.72./—A-( Signature: City b& Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ct.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06-011 Issue Date: 02/06/2006 Permit Expires On: 08/05/2006 Date: 02./0670 (o I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constryftion or the o ance of rk. I am authorized to sign and obtain this mechanical permit. 7 — Date: z — 6 - O 6 Print Name: t /C7Zgy 6o7� This permit shall become null and void if the work Is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC- Permit M06 -011 Printed: 02 -06 -2006 City of Tukwila 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS 4: Readily accessible access to roof mounted equipment is required. * *continued on next page ** Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 8836500060 Permit Number: M06 -011 Address: 349 UPLAND DR TUKW Status: ISSUED Suite No: Applied Date: 01/23/2006 Tenant: ELLIOTT BAY SERVICE TRANSFER Issue Date: 02/06/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 8: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of Public Health - Seattle and King County (206/296 - 4932). 10: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The Issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions M06 -011 Printed: 02 -06 -2006 Signature: C/ Print Name City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. 06 K. G e Date: Z —' doc: Conditions M06 -011 Printed: 02 -06 -2006 CITY OF TUKW& Community Development Department Public Works Department Permit Center 8300 Southcenter 8lvd., Suite 100 Tukwila, WA 98188 t-pT &O PERM IT#4 DOS -y07 Building Permit No. Mechanical PemtitNo. Moo -4 Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. ' pl King Co Assessor's Tax No.: 88 .3/, 5oOO/oO Site Address: . V4 9 I 1p L A IJ17 DRIVE Suite Number: Floor: Tenant Nanie: E LL.I OTT BAY S c Ft./ t r r' TR ft ASP New Tenant: ❑ Yes [ No Property Owners Name: Roe t1JGs OR E.GOLJ H ASARZ TRu.3Si Mailing Address: 13 25 NTH AvL 5T€ 1940 5 EATTI C cit SITE LOCATION 43 A State zip CONTACT PERSON Name: SOHIA R Aiarx=RSn1.3 Day Telephone: (N 2. ) 467-2 I.h - 9 Mailing Address: • J + . • y • • 8072 - to stain zip E-Mail Address: S A t ) D E R S o � a j,n`.g.1,3 H C C iirigiFax Number: ( Li25) 486, GENERAL CONTRACTOR INFORMATION - ( Mechanical Contractor information on back page) Company Name: R. MI LLER Co i3STRUCTIOL) Mailing Address: 14 f Tit RO Ao c SouTH I D t+ clans told er 8020 City State TAP Day Telephone: (2 o(0) SRI " 02?, E-Mail Address: 3COARRNW.sRCoi TRutTtot.3 eonii Fax Number: (204) 58S -030x, Contact Person: Sec-124 Co tr Contractor Registration Number: R M 1 LL el. 1 R O L 5 Expiration Date: 01/02 / 2008 etAn original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance" 1 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Zap Contact Person: E-Mail Address: 1 ENGINEER OF RECORD -All plans must be wet stamped by Engineer of Record Company Name: Romtfio)3 Gt,. 6Favo , Mailing Address: 2O21O0 IclaAvt= 130 SHOREti 0E WA 98155 tat Day Telephone: c2&&) 3 -334 3 E-Mail Address: S TtrHsitag2nCiY,Dn3Fn'Ata )&ERlLY .OWVI Fax Number: (a0&) 33 iat - 3363 Contact Person: ;Cot -►w' TOPAv4&) eppeSto plaits timpe'p®itap w(7•SaN) frond: 64103 a 5/ Page I Qty Day Telephone: Fax Number: State State rap Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<I00K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove •30.50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP/1,750,000 BTU Repair or Addition to Heat/RcMg/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator - Comm/Ind Other Mechanical Equipment volt 1 MECHANICAL PERMIT INFORMATION - 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: GRSI.ItaC MaP.HRt. >t(r1gL,IL3' - Mailing Address: PD RoX OS Woonit3VILt1: t A 9'807 110i-3 City State tip Contact Person: •TO14 la 2. AIJO&RSOU Day Telephone: 042;0 R7 -2359 E-Mail Address: 3 At.sn inla& IISUNCNECWANteAt. -Cr.oM Fax Number: (405) Licit, -451 Contractor Registration Number: GRSL.TMT 061-e n Expiration Date: 0 5/10/ '2 007 •'An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance" Valuation of Project (contractor's bid price): S IQ 000 Scope of Work (please provide detailed information): T vat n ,1 OP A i )E v. GW5 /E UE - ROpFroP tf1.7I u")1TN Utel.♦ nt,r.T S4STcrt • Uggi Residential: New.... ❑ Replacement.... ❑ Commercial: New .... e' Replacement .... ❑ Fuel Tyne: Electric ❑ Gas....[" Other: Indicate type of mechanical work being Stalled and the quantity below: PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.32 International Building Code (current edition). I HEREBY CERTIFY T11AT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE TATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O Signature: J Print Name: Kt=1_L d CRW L.> FOR C7 Mailing Address: PF) Ao i I f1P Date: 1 /23 /O(o Day Telephone:14266) 4F37 - 2 SS" G3 t)nfta >t11L LOA Q$ City State Date Application Expires: - 23-0 I Date Application Accepted: 1 - 23 -Oe, q: \yweio OSdix ahepp ®tapp&te 3004) Revd: 6405 be Page 4 Staff hripnL 1 Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: V►' City of Tukwila 8836500060 349 UPLAND DR TUKW R06 -00094 BLH ADMIN GASLINE MECHANICAL INC TRANSACTION LIST: Type Method 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 ELLIOTT BAY SERVICE TRANSFER Payment Check Description 7327 PLAN CHECK - NONRES 000/345.830 RECEIPT ACCOUNT ITEM LIST: Description Account Code Permit Number: Status: Applied Date: Issue Date: Payment Amount: 47.92 Payment Date: 01/23/2006 01:11 PM Balance: $221.66 Amount 47.92 Current Pmts 47.92 Total: 47.92 M06 -011 PENDING 01/23/2006 1532 01/24 9716 TOTAL 47.92 doc: Receipt - - -- - Printed: 01 -23 -2006 Project: et.,. / Orr 34 %SeRty. Type of Inspection: f7A/9 7 A ress y 7J.�LA�/� Date Called - o? — / 3 -O 4 Special Instructions: Date Wanted: a - i y —Og P.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit 1 ' ECTI' 0 CIT OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 T/ I Approved per applicable codes. Corrections required prior to approval. REINSPECTION FEE RE. UIRED. Prior t Inspection, fee must be at 6300 Southcenter Blvd., uite 100. Ca to sechedute reinspection. (Receipt No.: (Date: Pro ect: -- £ LL18TT f;At IQ. Type of Inspection: ri "QaL- A d;eis- Date Called: Special Instructions: Date Wanted: m. Cn /3 — O L Requester: Phone e N9: v s - 6 G.Sb t pproved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERM CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) -3670 Corrections required prior to approval. CO MENTS: 1(c 7;1162; , =fte 0 ge4e+ C' S7 !)O1 i al I Inspect Date: 0. )14 (...4.4.(x4 d 1 / 8.00 REINSPECTION FEE SQUIRED. Prio to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. all to sechedule reinspection. ceipt No.: 'Date: Project: P7/91 /fit, Type of Inspecti n: 70� /�// "iii Address: ` � y lJ4.� I N Date Called: qr( Special Instructi s: Date Wanted: 2r7-z24 a.m. S Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECT •N NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 n(IApproved per applicable codes. COMMENTS: El Corrections required prior to approval. $58.00 Rt1N5t FE t REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. (Receipt No.: Date: January 24, 2006 John R. Anderson PO Box 108 Woodinville, WA 98072 -1108 RE: Letter of Incomplete Application # 1 Mechanical Permit Application M06 -011 Elliot Bay Service Transfer — 649 Upland Dr Dear Mr. Anderson: This letter is to inform you that your application received at the City of Tukwila Permit Center on January 23, 2006 is determined to be incomplete. Before your application can continue the plan review process the attached items from the following department(s) need to be addressed: Building Department: Allen Johannessen, at 206 433 -7163, if you have any questions concerning the attached memo. Please address the above comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail pr by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 433 - 7165. Sincerely, ifer Marshall Permit Technician Enclosures File: Permit M06 -011 City of Tukwila Department of Community Development Steve Lancaster, Director P:Uennitir Incomplete Letters U006Ut06-011 Incomplete Ltr N I.DOC Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206- 431 -3665 Determination of Completeness Memo Date: January 24, 2006 Project Name: Elliott Bay Service Transfer Remit #: M06-011 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner A Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). 1 Provide a building site plan. Site plan shall show location of roof access for roof mounted mechanical equipment. Roof access shall meet requirements of the mechanical code for equipment and appliances installed on roof or elevated structures. (IMO 106.3.1 & 306.5) 2 Provide details to show how equipment shall be secured to the roof, roof curb details and where roof framing shah be sufficient to support the new equipment Should there be questions concerning the above requirements, contact the Building Division at 206-431- 3670. No further comments at this time. DEPARTMENTS: g Division Public Works Complete Comments: ''PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M06 -011 DATE: 01 -31 -06 PROJECT NAME: ELLIOTT BAY SERVICE TRANSFER SITE ADDRESS: 349 UPLAND DR Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Planning Division Permit Coordinator o o DUE DATE: 02-02-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT NG: Please Route d Structural Review Required REVIEWER'S INITIALS: Approved ❑ Notation: Documents/routing slip.doc 2-28-02 APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: Approved with Conditions No further Review Required DATE: DUE DATE: 03-02-06 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Public Works ACTIVITY NUMBER: M06 -011 DATE: 01 -23 -06 PROJECT NAME: ELLIOTT BAY SERVICE TRANSFER SITE ADDRESS: 349 UPLAND DR X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bui i ing Iwsion j F ire reve ion PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Comments: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 Incomplete ❑ Permit Coordinator DUE DATE: 01-24-06 Permit Center Use Only INCOMPLETE LETTER MAILED: DI ail di LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required DATE: Planning Division C Not Applicable ❑ DUE DATE: 02-21-06 Approved with Conditions Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: I REVISION SUBMITTAL 1 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: I— 31 -0(0 Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Plan Check/Permit Number: ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Biuilding Inspector or Plans Examiner ELLIOTT BAY SERVICE TRANSFER Project Address: 349 UPLAND DR Contact Person: tiDhv1 11rkAe - Phone Number: • Summary of Revision: 6 tk Lit ( ; -L SI1c V h r7-C Lo c_L. W . v Sheet Number(s): in — 7 "Cloud" or highlight all areas of revision Including date of revision Received at the City of Tukwila Permit Center by/ Entered in Permits Plus on a*M•aP \applications \fomu - applications on line\revision submittal Created: 8-13-2004 Revised: M06 -011 t` f 1MW- „;14,t,. 1nt0„,rdr.a Qco ' Dx3 N/( - 2 Steven M. Mullet, Mayor Steve Lancaster, Director pRVy JAN 3 1 1000 CENTER PX /S7'soK License RMILLCI190L5 Licensee Name R MILLER CONSTRUCTION CO INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600389405 Verify Workers Cnmp Premium Status Ind. Ins. Account Id 40867100 Business Type CORPORATION Address 1 146 3RD AVE 5 Address 2 City EDMONDS County SNOHOMISH State WA Zip 98020 Phone 2065830238 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 6/25/1981 Expiration Date 1/2/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Look Up a Contractor, Electrir+an or Plumber License Detail %ow Printer Friendly Version General /Specialty Contractor License Information Page 1 of 3 Topic Index I Contact Info . 1 Search I Home Safety Claims & Insurance Workplace Rights Trades ft Licensing Look Up a Contractor, Electrician or Plumber Find a Law or Rule Get a Form or Publication A business registered as a construction contractor with L8:1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: / /fortress .wa.gov /lni/bbip/Detail.aspx ?License= RMILLCI190L5 02/06/2006 . GRILLES, .DIFFUSERS SCHEDULE , CALLOUT 1 t SCRP11111 , A MIN CFII FAKE N BASIS 01 DESIGN CD-1 aim 01FRIS3t 0-360 241124 SHODAPACER MA SDKS t3I-2 CERl16 OFRISER :0-150 10114 91 101NI R 950 SOWS - I. , - - '0N • 10-1 - MILE 10-400 MA SHODIMER 106 SEWS -1 "ERAMI MLLE 1 0-20110 2k24 1910EWITER SOS SEES I EQUIP NO. RTU -1 I tit A 4 DISCHARGE VERTICAL 1950 AIRFLOW, CFM i (TG- -1 fRTU -1 (ON ROOF) (18x18 i _ i TG -1 Y = 1 AlimaimmiimMulmmIr 0. • f SCALE: 1/4 = 1' -0• ESP, IN WG (1) FLOOR PLAN S1 is fit+ shell be marz c; ttricr.r. SUPPLY FAN MINIMUM OSA 250 arommammormass. a oo normsamposar mama mom imiftwils wawa= N A A 18x18 MOTOR HP 1 • T - .1 a c 1 COOUNG CAPACITY, SEER MBH 58 120 NOTE: EXISTING RESTROOM EXHAUST \SYSTEM TO REMAIN. 90 INPUT. MBH f tl RG-1 II j 70 NOTES: (1) ESP IS EXTERNAL TO UNIT CASING; DOES NOT INCLUDE CASING, CLEAN FILTER, NET COIL. OR AUX HEAT LOSSES. (2) PROVIDE ECONOMIZER AND POOR EXHAUST OPTION. SCHEDULES HEATING CAP, STAGES MBH 1 e HVAC UNIT SCHEDULE(ELEC COOL /GAS HEAT) AFUE X 78.6 it 1 t/ POurmb:n J (� CZS p r City Or �"� G DIVISION VOLTAGE I ELECTRICAL MCA MOCP i i • C BASIS OF DESIGN -- CARRIER 4eac060090 THIS AREA IS EXISTIN AND IS NOT INCLUDED IN THE SCOPE OF WORK. !,-ocR.4 E rases. w�MO,/�LOrP -OI � J PINI NOM apptowi idesd d etas end wham ftproe1 of c nlllucUOA doomeasis doffs not a>itlimmlui the violation Of anlr =IOW W c or mamma flesiet of domed • Copy and ,Carbons ads City of Aiwa IllUILDiDIS DIVISION Rc :card draw ih;c of ncc actual lrstailaxon shall he ' i ini to the !ru dim owner a Nth m aft day of the Jalc cN c■•cm a:ccptattcc per SC.attc ' n c s ; ; : C .ldc s St & 1 Srctirn ! 4 I c► MECHANICAL Completion of Commimeiosiog for Meeba .ical Sriteno Art •.i+er mama! awl marnievaance ma al cha :i t ;vv., &'J k' TN: t‘a w3wc . ncr per a: C Section !4 i = Alf 11' \c :•' cvn Juit he 1•4ancc-d sad .a r► rxtcn !uiatnc rcro t 41.t#► he prw kk-d to ler twiner trot STA. sectww t: i t For +achoa`c-. sernibeased Amon, Jib,' * «046c11Itc kart ,kfiakNJ art SIC Section t412 H% cosvark c ∎ c shag he tested. cae*+ratcd aa.1 a&ICCacd_ wmpies crk .44 oraltacit shoe he lewd w co% re chat tip operate rR ,*: I.! R rtA reCNiratwisek and arscoved rFarm, and a comelier "emit last rer.ce ionr4 Jed resarits 41sail !re f i l e d .► aA tic mow, ref sit' stomas 1 . 1 t . . 4 For AR caMct .I AC orriorr! , sycaeavri he less td, sweated arad adorned gcgacscrt rplevatnow t' weed tr erecter dear *sr ("woe as ancioal Nall aptocl6C11100006 a vd apnr►ced p Fer ( ('C *+r ; 416 4 Z. 11naMs1 Rte Allotci he kiestairst per 'cf ( ems 1.14. _ 4 5gtimmaae % 0011111110MMINIK nest of t�^ct �rnc+d G� aad moilb Asa be Rol / war » imensoc of a Swat ceitaiwate ot* tocemmrs •cr SIC Same 1411•4 2 i 1110. 4 _ aid 1 a ciffew et foal eassaysswarg meet ot tts Fes' c edire% and remalt‘ilimill k Sled vivik ti c aver per SFC Swam APPROX WEIGHT LBS 475 1 SAL NOTE — M ECHANICAL 1. REFERENCE TO RELATED WORK: 'REF' INDICATIONS DENOTE WORK COVERED ELSEWHERE (ARCHITECTURAL. STRUCTURAL, CINL. ELECTRICAL. LANDSCAPE, OR KITCHEN), OR ITEM BASED ON A SPECIFIC MANUFACTURER'S DIMENSIONS (VERIFY). 2. ELECTRICAL CHARACTERISTICS: REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS (VOLTAGES, ETC.) OF MECHANICAL EQUIPMENT, UNLESS OTHERWISE INDICATED. . CODES: COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL. BE PER THE APPUCABLE BUILDING, MECHANICAL, ENERGY, PLUMBING, F1RE, AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL AHJ. 4. MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF ALL MECHANICAL EQUIPMENT WITHIN THE STRUCTURE. RATED PENETRATION: DUCT PENETRATIONS THROUGH RATED ENCLOSURES SHALL BE FIRE /SMOKE DAMPERED PER THE LATEST EDITION OF THE UNDERWRITERS LABORATORIES(UL) ARE RESISTANCE WITH HOURLY RATINGS FOR THROUGH — PENETRATION ARE STOPS SYSTEM VOLUME 02. OR SHALL BE INSTALLED IN STRICT ACCORDANCE MAIN THE MANUFACTURER'S UL USTINGS (3M OR EQUIVALENT). • EXPOSED PIPING: PROVIDE CHROME PLATING FOR EXPOSED PIPING IN FINISHED ROOMS. 8. SHAFT AND PLENUM CONNECTIONS: SEAL CONNECTIONS TO AIR SHAFTS AIRTIGHT. PROVIDE AIRTIGHT SEAL AROUND IISULUENILIEMAQIES 1. ENERGY CODE: AS A MINIMUM, COMPLY WITH THICKNESSES AND TYPES USTED IN ENERGY CODE ENFORCED BY AHJ. 2. EXTENT OF INTERNAL DUCT UNING: A. GRILLE AND DIFFUSER BOXES AND BOOTS. B. TRANSFER DUCTS. 3. MISCE.ANEOUS DUCT FITTINGS (CONICAL TAKEOFFS, ETC.): WRAP WITH INSULATION FOR CONDENSATION CONTROL S 1EET METAL NOTES 1. REFERENCE: SMACNA HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE, CURRENT EDITION (SMACNA HVACDCS). 2. CLEARANCE: COORDINATE DUCTWORK WITH MISCELLANEOUS OBSTRUCTIONS IN CEIUNG SPACE. 3. DUCTWORK SIZES: SIZES INDICATED ARE INSIDE CLEAR DIMENSIONS. 4. ROUND ELBOWS AND OFFSETS: FULL RADIUS (R/b = 1.5). 5 —PIECE SEGMENTED OR STAMPED. REFER TO SMACNA HVACDCS FIG 2 -7, 3-3. DO NOT USE ANGLED OFFSET (TYPE 1). MITERED OFFSET (TYPE 2) MAY BE USED UP TO 30 DEGREE OFFSET ANGLE. 5. ROUND TEES AND LATERALS: CONICAL WEE PER SMACNA HVACDCS FIG 3-5; DO NOT USE STRAIGHT TEE; DO NOT USE CONICAL SADDLE TAP FOR EXPOSED DUCTWORK IN FINISHED SPACES. 90-- DEGREE TEE VAIN OVAL TO ROUND TAP, LATERAL, AND 45— DEGREE RECTANGULAR LEAD —IN PER SMACNA HVACDCS FIG 3-4. 6. RECTANGULAR ELBOWS AND OFFSET'S: FULL RADIUS WHERE SPACE PERMITS, R/W = 1.5; OTHERWISE USE SQUARE CORNER ELBOW WITH TURNING VANES. 7. RECTANGULAR DIVIDED FLOW ATTNGS: USE GENERALLY, EXCEPT BRANCHES TO TERMINALS; SMACNA HVACOCS FIG 2 -5, 349 UPLA4D Oi'lIE . PENETRATIONS: PROVIDE ESCUTCHEON PLATES F. R EXPOSED PIPING PENETRATIONS AND SHEET METAL FLASHING FOR EXPOSED DUCTWORK PENETRATIONS. • GENERAL NOTES EXTENT OF EXTERNAL DUCT INSULATION: A. SUPPLY AND RETURN AIR IN UNCONDITIONED SPACES, MECHANICAL ROOMS, ELECTRICAL ROOMS, AND EQUIPMENT ROOMS NOT SPECIFIED TO BE INTERNALLY UNED. B. SUPPLY AIR ABOVE CEIUNGS. C. OUTDOOR AiR INTAKE. VICINITY MAP • • 2 UP UP [ UP UP UP 1%1 FSD Fo T -12:D=21- CD- -12x12 400 18x12 0 i==1 DOWN DOWN VI DOWN UP FSD FD - < izmoiroP ARCHITECTURAL BACKGROUND (THIN LINE) NEW MECHANICAL WORK (HEAVY UNE) MATCHUNE OR PROPERTY UNE TYPICAL EQUIPMENT DESIGNATION (EXHAUST FAN SHOWN) ROOM THERMOSTAT OR TEMPERATURE TRANSMITTER DUCT SMOKE DETECTOR DUCT (1ST FIGURE = SIDE SHOWN, 2ND FIGURE = SIDE NOT SHOWN) DUCT SECTION, POSITIVE PRESSURE DUCT SECTION, NEGATIVE PRESSURE ROUND DUCT SECTION DUCT PENETRATION THRU FLOOR OR ROOF FIRE /SMOKE DAMPER ( -4= HORIZ DUCT, —♦►= VERT DUCT), 2 -HR RATED, UON FIRE DAMPER 90' ELBOW, R/D OR R/W=1.5 SQUARE CORNER ELBOW WITH TURNING VANES 90' TAKE -OFF OR TEE 45' LATERAL TAKE -OFF LEGEND TRANSITION OR REDUCER (FOT= FLAT ON TOP, FOB =FLIT ON BOTTOM) 90' RECTANGULAR TAKE -OFF WITH 45' TAPER 90' DIVERGING RECTANGULAR TEE, EITHER RADIUS OR TURNING VANES ROUND DUCT INDICATOR DIFFUSER /GRILLE TYPE, AND NUMBER OR SIZE 400 �10R DESIGN CFM (WHERE ) CEIUNG DIFFUSER (FLOW ARROWS SHOWN ONLY F AIRFLOW NOT SYMMETRICAL) CEIUNG RETURN/EXHAUST GRILLE WALL SUPPLY GRIU E (SG) WALL RETURN/EXHAUST GRILLE (RG, EG) TRANSFER GRILLE (TG), DUCT CONNECTED, WALL MOUNTED WITH OPTIONAL CAMS OWN GRI.IE. CLING MOUNTED 'NTH FULL -S ZED LSD DUCT CONNECTION AIRFLOW THRU DOOR GRILLE OR UNDERCUT W/P11ONAL CM SHOWN FLEXIBLE DUCT ACU AIR CONDITIONING UNIT AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDUNG UNIT BDD BACKDRAFT DAMPER BTUH BRITISH THERMAL UNIT PER HOUR CBBDD COUNTERBALANCED BACKDRAFT DAMPER CC COOUNG COIL CD CEIUNG DIFFUSER CFM CUBIC FEET PER MINUTE CLG CEIUNG, COOUNG COMB COMBUSTION CONTR CONTRACTOR D DRAIN, DIAMETER DB DRY BULB, DECIBEL DISCH DISCHARGE DMPR DAMPER DN DOWN EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EFF EFFICIENCY EG EXHAUST GRILLE, ENGINE GENERATOR EL ELEVATION ELEC ELECTRIC EQUIV EQUIVALENT ESP EXTERNAL STATIC PRESSURE EXT EXTERIOR, EXTERNAL F FAHRENHEIT FCU FAN COIL UNIT FD FIRE DAMPER, FLOOR DRAIN FIR FLOOR FLTR FILTER FPM FEET PER MINUTE FPS FEET PER SECOND G GAS GWB GYPSUM WALLBOARD HORIZ HORIZONTAL HP HORSEPOWER HVAC HEATING, VENTILATING, AND AIR CONDITIONING HVACDCS HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE (SMACNA) KW KILOWATT L LONG, LENGTH MBH THOUSAND BTU PER HOUR MECH MECHANICAL MCA MINIMUM CIRCUIT AMPACITY MOCP MAXIMUM OVER CURRENT PROTECTIOP MTD MOUNTED OA OUTDOOR AIR OBD OPPOSED BLADE DAMPER 00 OUTSIDE DIMENSION OR DIAMETER OPNG OPENING PD PRESSURE DROP, PUMPED DRAIN POC POINT OF CONNECTION PRV PRESSURE REDUCING VALVE PSIG POUNDS PER SQUARE INCH GAUGE RA RETURN AIR REF REFERENCE RG RETURN GRILLE SA SUPPLY AIR SCH SCHEDULE SF SUPPLY FAN, SQUARE FOOT SENS SENSIBLE SG SUPPLY GRILLE SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASS01AT10N SO SCREENED OPENING SP STATIC PRESSURE TG TRANSFER GRILLE TYP TYPICAL UON UNLESS OTHERVASE NOTED VD VOLUME DAMPER DRAWING INDEX M-1 1ECEM. NOTES, SCHEDULES, VICINITY ru M -1 LEGEND, NOTES, SCHEDULES, VICINITY MAP, FLOOR PLAN, DRAIAANG INDEX Y -2 DETAILS M -2 DETAILS 1 CODE �..IN��CE RECEIVED anr OF TLPMAA AN z r� ,� -2r>al MOAT C',ENTETI • • - c • 0 • ♦ , • ;c w O ao • :t 8: O � c � r; E a c o -o • .c • C ° v 0 C c C v C< ; W D • jc o 0 • .o : • O p 0 • o ° to 0O c • V o o 3 a j 0 0 V V • • c c c • � tt - ii ° c • MM • 0 ° c c � 0 >+ �i< to. L • 4 ;F cMA0 - ' c • 0 • a • 0 cr 1 O 0 c C • • c C0 c W c 0 Cassano lalschenical illy. Si► Elliot Md. Snohomish WA WM ls 1 EXPIRES: 08/31/07 I 0 W 0 w W U W 0 0- DATE: 1/12/2006 1 SHEET TI TIE: LLCM NOTE'S, 9QELES. 1ACMTY now. ROM PUN. DI= OF ORASOCS W cr w (1) ry O M CO (0 z 0 0 co M 0 CV 0 L�. Z o O d U) p.m W � O Z � V Z W ■ SHEET NO. M-1 , I DESCRIPTION SNOISIA3b I Ada - I. , - - '0N • EQUIP NO. RTU -1 I tit A 4 DISCHARGE VERTICAL 1950 AIRFLOW, CFM i (TG- -1 fRTU -1 (ON ROOF) (18x18 i _ i TG -1 Y = 1 AlimaimmiimMulmmIr 0. • f SCALE: 1/4 = 1' -0• ESP, IN WG (1) FLOOR PLAN S1 is fit+ shell be marz c; ttricr.r. SUPPLY FAN MINIMUM OSA 250 arommammormass. a oo normsamposar mama mom imiftwils wawa= N A A 18x18 MOTOR HP 1 • T - .1 a c 1 COOUNG CAPACITY, SEER MBH 58 120 NOTE: EXISTING RESTROOM EXHAUST \SYSTEM TO REMAIN. 90 INPUT. MBH f tl RG-1 II j 70 NOTES: (1) ESP IS EXTERNAL TO UNIT CASING; DOES NOT INCLUDE CASING, CLEAN FILTER, NET COIL. OR AUX HEAT LOSSES. (2) PROVIDE ECONOMIZER AND POOR EXHAUST OPTION. SCHEDULES HEATING CAP, STAGES MBH 1 e HVAC UNIT SCHEDULE(ELEC COOL /GAS HEAT) AFUE X 78.6 it 1 t/ POurmb:n J (� CZS p r City Or �"� G DIVISION VOLTAGE I ELECTRICAL MCA MOCP i i • C BASIS OF DESIGN -- CARRIER 4eac060090 THIS AREA IS EXISTIN AND IS NOT INCLUDED IN THE SCOPE OF WORK. !,-ocR.4 E rases. w�MO,/�LOrP -OI � J PINI NOM apptowi idesd d etas end wham ftproe1 of c nlllucUOA doomeasis doffs not a>itlimmlui the violation Of anlr =IOW W c or mamma flesiet of domed • Copy and ,Carbons ads City of Aiwa IllUILDiDIS DIVISION Rc :card draw ih;c of ncc actual lrstailaxon shall he ' i ini to the !ru dim owner a Nth m aft day of the Jalc cN c■•cm a:ccptattcc per SC.attc ' n c s ; ; : C .ldc s St & 1 Srctirn ! 4 I c► MECHANICAL Completion of Commimeiosiog for Meeba .ical Sriteno Art •.i+er mama! awl marnievaance ma al cha :i t ;vv., &'J k' TN: t‘a w3wc . ncr per a: C Section !4 i = Alf 11' \c :•' cvn Juit he 1•4ancc-d sad .a r► rxtcn !uiatnc rcro t 41.t#► he prw kk-d to ler twiner trot STA. sectww t: i t For +achoa`c-. sernibeased Amon, Jib,' * «046c11Itc kart ,kfiakNJ art SIC Section t412 H% cosvark c ∎ c shag he tested. cae*+ratcd aa.1 a&ICCacd_ wmpies crk .44 oraltacit shoe he lewd w co% re chat tip operate rR ,*: I.! R rtA reCNiratwisek and arscoved rFarm, and a comelier "emit last rer.ce ionr4 Jed resarits 41sail !re f i l e d .► aA tic mow, ref sit' stomas 1 . 1 t . . 4 For AR caMct .I AC orriorr! , sycaeavri he less td, sweated arad adorned gcgacscrt rplevatnow t' weed tr erecter dear *sr ("woe as ancioal Nall aptocl6C11100006 a vd apnr►ced p Fer ( ('C *+r ; 416 4 Z. 11naMs1 Rte Allotci he kiestairst per 'cf ( ems 1.14. _ 4 5gtimmaae % 0011111110MMINIK nest of t�^ct �rnc+d G� aad moilb Asa be Rol / war » imensoc of a Swat ceitaiwate ot* tocemmrs •cr SIC Same 1411•4 2 i 1110. 4 _ aid 1 a ciffew et foal eassaysswarg meet ot tts Fes' c edire% and remalt‘ilimill k Sled vivik ti c aver per SFC Swam APPROX WEIGHT LBS 475 1 SAL NOTE — M ECHANICAL 1. REFERENCE TO RELATED WORK: 'REF' INDICATIONS DENOTE WORK COVERED ELSEWHERE (ARCHITECTURAL. STRUCTURAL, CINL. ELECTRICAL. LANDSCAPE, OR KITCHEN), OR ITEM BASED ON A SPECIFIC MANUFACTURER'S DIMENSIONS (VERIFY). 2. ELECTRICAL CHARACTERISTICS: REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS (VOLTAGES, ETC.) OF MECHANICAL EQUIPMENT, UNLESS OTHERWISE INDICATED. . CODES: COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL. BE PER THE APPUCABLE BUILDING, MECHANICAL, ENERGY, PLUMBING, F1RE, AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL AHJ. 4. MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF ALL MECHANICAL EQUIPMENT WITHIN THE STRUCTURE. RATED PENETRATION: DUCT PENETRATIONS THROUGH RATED ENCLOSURES SHALL BE FIRE /SMOKE DAMPERED PER THE LATEST EDITION OF THE UNDERWRITERS LABORATORIES(UL) ARE RESISTANCE WITH HOURLY RATINGS FOR THROUGH — PENETRATION ARE STOPS SYSTEM VOLUME 02. OR SHALL BE INSTALLED IN STRICT ACCORDANCE MAIN THE MANUFACTURER'S UL USTINGS (3M OR EQUIVALENT). • EXPOSED PIPING: PROVIDE CHROME PLATING FOR EXPOSED PIPING IN FINISHED ROOMS. 8. SHAFT AND PLENUM CONNECTIONS: SEAL CONNECTIONS TO AIR SHAFTS AIRTIGHT. PROVIDE AIRTIGHT SEAL AROUND IISULUENILIEMAQIES 1. ENERGY CODE: AS A MINIMUM, COMPLY WITH THICKNESSES AND TYPES USTED IN ENERGY CODE ENFORCED BY AHJ. 2. EXTENT OF INTERNAL DUCT UNING: A. GRILLE AND DIFFUSER BOXES AND BOOTS. B. TRANSFER DUCTS. 3. MISCE.ANEOUS DUCT FITTINGS (CONICAL TAKEOFFS, ETC.): WRAP WITH INSULATION FOR CONDENSATION CONTROL S 1EET METAL NOTES 1. REFERENCE: SMACNA HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE, CURRENT EDITION (SMACNA HVACDCS). 2. CLEARANCE: COORDINATE DUCTWORK WITH MISCELLANEOUS OBSTRUCTIONS IN CEIUNG SPACE. 3. DUCTWORK SIZES: SIZES INDICATED ARE INSIDE CLEAR DIMENSIONS. 4. ROUND ELBOWS AND OFFSETS: FULL RADIUS (R/b = 1.5). 5 —PIECE SEGMENTED OR STAMPED. REFER TO SMACNA HVACDCS FIG 2 -7, 3-3. DO NOT USE ANGLED OFFSET (TYPE 1). MITERED OFFSET (TYPE 2) MAY BE USED UP TO 30 DEGREE OFFSET ANGLE. 5. ROUND TEES AND LATERALS: CONICAL WEE PER SMACNA HVACDCS FIG 3-5; DO NOT USE STRAIGHT TEE; DO NOT USE CONICAL SADDLE TAP FOR EXPOSED DUCTWORK IN FINISHED SPACES. 90-- DEGREE TEE VAIN OVAL TO ROUND TAP, LATERAL, AND 45— DEGREE RECTANGULAR LEAD —IN PER SMACNA HVACDCS FIG 3-4. 6. RECTANGULAR ELBOWS AND OFFSET'S: FULL RADIUS WHERE SPACE PERMITS, R/W = 1.5; OTHERWISE USE SQUARE CORNER ELBOW WITH TURNING VANES. 7. RECTANGULAR DIVIDED FLOW ATTNGS: USE GENERALLY, EXCEPT BRANCHES TO TERMINALS; SMACNA HVACOCS FIG 2 -5, 349 UPLA4D Oi'lIE . PENETRATIONS: PROVIDE ESCUTCHEON PLATES F. R EXPOSED PIPING PENETRATIONS AND SHEET METAL FLASHING FOR EXPOSED DUCTWORK PENETRATIONS. • GENERAL NOTES EXTENT OF EXTERNAL DUCT INSULATION: A. SUPPLY AND RETURN AIR IN UNCONDITIONED SPACES, MECHANICAL ROOMS, ELECTRICAL ROOMS, AND EQUIPMENT ROOMS NOT SPECIFIED TO BE INTERNALLY UNED. B. SUPPLY AIR ABOVE CEIUNGS. C. OUTDOOR AiR INTAKE. VICINITY MAP • • 2 UP UP [ UP UP UP 1%1 FSD Fo T -12:D=21- CD- -12x12 400 18x12 0 i==1 DOWN DOWN VI DOWN UP FSD FD - < izmoiroP ARCHITECTURAL BACKGROUND (THIN LINE) NEW MECHANICAL WORK (HEAVY UNE) MATCHUNE OR PROPERTY UNE TYPICAL EQUIPMENT DESIGNATION (EXHAUST FAN SHOWN) ROOM THERMOSTAT OR TEMPERATURE TRANSMITTER DUCT SMOKE DETECTOR DUCT (1ST FIGURE = SIDE SHOWN, 2ND FIGURE = SIDE NOT SHOWN) DUCT SECTION, POSITIVE PRESSURE DUCT SECTION, NEGATIVE PRESSURE ROUND DUCT SECTION DUCT PENETRATION THRU FLOOR OR ROOF FIRE /SMOKE DAMPER ( -4= HORIZ DUCT, —♦►= VERT DUCT), 2 -HR RATED, UON FIRE DAMPER 90' ELBOW, R/D OR R/W=1.5 SQUARE CORNER ELBOW WITH TURNING VANES 90' TAKE -OFF OR TEE 45' LATERAL TAKE -OFF LEGEND TRANSITION OR REDUCER (FOT= FLAT ON TOP, FOB =FLIT ON BOTTOM) 90' RECTANGULAR TAKE -OFF WITH 45' TAPER 90' DIVERGING RECTANGULAR TEE, EITHER RADIUS OR TURNING VANES ROUND DUCT INDICATOR DIFFUSER /GRILLE TYPE, AND NUMBER OR SIZE 400 �10R DESIGN CFM (WHERE ) CEIUNG DIFFUSER (FLOW ARROWS SHOWN ONLY F AIRFLOW NOT SYMMETRICAL) CEIUNG RETURN/EXHAUST GRILLE WALL SUPPLY GRIU E (SG) WALL RETURN/EXHAUST GRILLE (RG, EG) TRANSFER GRILLE (TG), DUCT CONNECTED, WALL MOUNTED WITH OPTIONAL CAMS OWN GRI.IE. CLING MOUNTED 'NTH FULL -S ZED LSD DUCT CONNECTION AIRFLOW THRU DOOR GRILLE OR UNDERCUT W/P11ONAL CM SHOWN FLEXIBLE DUCT ACU AIR CONDITIONING UNIT AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDUNG UNIT BDD BACKDRAFT DAMPER BTUH BRITISH THERMAL UNIT PER HOUR CBBDD COUNTERBALANCED BACKDRAFT DAMPER CC COOUNG COIL CD CEIUNG DIFFUSER CFM CUBIC FEET PER MINUTE CLG CEIUNG, COOUNG COMB COMBUSTION CONTR CONTRACTOR D DRAIN, DIAMETER DB DRY BULB, DECIBEL DISCH DISCHARGE DMPR DAMPER DN DOWN EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EFF EFFICIENCY EG EXHAUST GRILLE, ENGINE GENERATOR EL ELEVATION ELEC ELECTRIC EQUIV EQUIVALENT ESP EXTERNAL STATIC PRESSURE EXT EXTERIOR, EXTERNAL F FAHRENHEIT FCU FAN COIL UNIT FD FIRE DAMPER, FLOOR DRAIN FIR FLOOR FLTR FILTER FPM FEET PER MINUTE FPS FEET PER SECOND G GAS GWB GYPSUM WALLBOARD HORIZ HORIZONTAL HP HORSEPOWER HVAC HEATING, VENTILATING, AND AIR CONDITIONING HVACDCS HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE (SMACNA) KW KILOWATT L LONG, LENGTH MBH THOUSAND BTU PER HOUR MECH MECHANICAL MCA MINIMUM CIRCUIT AMPACITY MOCP MAXIMUM OVER CURRENT PROTECTIOP MTD MOUNTED OA OUTDOOR AIR OBD OPPOSED BLADE DAMPER 00 OUTSIDE DIMENSION OR DIAMETER OPNG OPENING PD PRESSURE DROP, PUMPED DRAIN POC POINT OF CONNECTION PRV PRESSURE REDUCING VALVE PSIG POUNDS PER SQUARE INCH GAUGE RA RETURN AIR REF REFERENCE RG RETURN GRILLE SA SUPPLY AIR SCH SCHEDULE SF SUPPLY FAN, SQUARE FOOT SENS SENSIBLE SG SUPPLY GRILLE SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASS01AT10N SO SCREENED OPENING SP STATIC PRESSURE TG TRANSFER GRILLE TYP TYPICAL UON UNLESS OTHERVASE NOTED VD VOLUME DAMPER DRAWING INDEX M-1 1ECEM. NOTES, SCHEDULES, VICINITY ru M -1 LEGEND, NOTES, SCHEDULES, VICINITY MAP, FLOOR PLAN, DRAIAANG INDEX Y -2 DETAILS M -2 DETAILS 1 CODE �..IN��CE RECEIVED anr OF TLPMAA AN z r� ,� -2r>al MOAT C',ENTETI • • - c • 0 • ♦ , • ;c w O ao • :t 8: O � c � r; E a c o -o • .c • C ° v 0 C c C v C< ; W D • jc o 0 • .o : • O p 0 • o ° to 0O c • V o o 3 a j 0 0 V V • • c c c • � tt - ii ° c • MM • 0 ° c c � 0 >+ �i< to. L • 4 ;F cMA0 - ' c • 0 • a • 0 cr 1 O 0 c C • • c C0 c W c 0 Cassano lalschenical illy. Si► Elliot Md. Snohomish WA WM ls 1 EXPIRES: 08/31/07 I 0 W 0 w W U W 0 0- DATE: 1/12/2006 1 SHEET TI TIE: LLCM NOTE'S, 9QELES. 1ACMTY now. ROM PUN. DI= OF ORASOCS W cr w (1) ry O M CO (0 z 0 0 co M 0 CV 0 L�. Z o O d U) p.m W � O Z � V Z W ■ SHEET NO. M-1 • i 1 1 1 1 1 • r9, P 4 ' N%) • I0 1 allemmammh looiioo• uo{ ;Dr ;.uo3 34 •1I lots LS *ft =If4 !i Tel NOM lo0i /oE /10 Thee drawings were developed for the exclusive use by Collins Mechanical on a design /build concept. They ors to be used only with written permission of Collins Mechanical and Robison Engineering. Gosline Mechanical contact: John Anderson, President Robison Engineering contact: Mork Robison, President PROJECT: ELLIOTT BAY TRA \SFER ROBISON 20300 19th Ave. NE Shoreline, WA 98155 ENGINEERING, INC PHONE: (206)364 -3343 Fax:(206)364— 3363 DRAWN: DESIGNED: CHECKED: APPROVED: NO. DATE DESCRIPTION REVISIONS