Loading...
HomeMy WebLinkAboutPermit M06-107 - HOUHAKNAMM / STEIGER RESIDENCEHOUHAKNAMM /STEEGER RESIDENCE 4822 S 164 ST IPIRED 12 - 02 - 06 M06 -107 • • • Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: DESCRIPTION OF WORK: REPLACING GAS FURNACE. Value of Mechanical: $2,984.83 Type of Fire Protection: doe: IMC- Permit City stvi Tukwila Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall /Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct. Ventilation System Hood and Duct Incinerator: Domestic Commercial /Industrial Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us 8849700010 4822 S 164 ST TUKW HOUHAKNAMM /STEIGER RESIDENCE 4822 S 164 ST, TUKWILA WA KOV HOUHAKNAMM 4822 S 164TH ST, TUKWILA WA Contact Person: Name: GLENDALE HEATING, RITA WALTERS Address: 12462 DES MOINES MEMORIAL DR, SEATTLE WA Contractor: Name: GLENDALE HEATING & A/C Address: 12462 DES MOINES WY S, SEATTLE, WA Contractor License No: GLENDHA053Q2 gauiP MECHANICAL PERMIT ENT TYPE AND QUANTITY * *continued on next page ** M06 -107 v Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 243 -7700 Phone: 206- 243 -7700 Expiration Date: 11/02/2007 M06 -107 06/05/2006 12/02/2006 Fees Collected: $158.94 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 3 -15 HP /500,000 BTU 15 -30 HP /1,000,000 BTU., 30 -50 HP /1,750,000 BTU.. 50+ HP /1,750,000 BTU Fire Damper Diffuser Thermostat Wood/Gas Stove Water Heater Emergency Generator Other Mechanical Equipment... Steven M. Mullet, Mayor Steve Lancaster, Director Printed: 06 -05 -2006 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this regulating constru Signature: doc: IMC- Permit City b& Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -107 Issue Date: 06/05/2006 Permit Expires On: 12/02/2006 i t Ut1 Date: 5 trJi mit does not presum to give authority to violate or cancel the provisions of any other state or local laws or th-_g -, ormanc f rk. I am authorized to sign and obtain this mechanical permit. Date: 6- 3 6 € Print Name: 60em-,o A 7F This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M06 -107 Printed: 06 -05 -2006 City @Pi Tukwila 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Conditions Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206- 431 -3665 Web site: cttukwila.wa.us PERMIT CONDITIONS 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. * *continued on next page ** Steven M. Mullet, Mayor Steve Lancaster, Director Parcel No.: 8849700010 Permit Number: M06 -107 Address. 4822 S 164 ST TUKW Status: ISSUED Suite No: Applied Date: 06/02/2006 Tenant: HOUHAKNAMM /STEIGER RESIDENCE Issue Date: 06/05/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an Ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4 inches shall be maintained above the controls with the strapping. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit Issued by the Washington State Department of Labor and Industries (206/248 - 6630). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The Issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors In the construction documents and other data. M06 -107 Printed: 06 -05 -2006 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction of the performance of work. Signature: Print Name: doc: Conditions City th Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us a Steven M. Mullet, Mayor Steve Lancaster, Director Date: e-.c- 06 M06 -107 Printed: 06 -05 -2006 SITE LOCATION Site Address: CITY OF TUKWIL Community Development Department Public Works Department Permit Center 8300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 W 22_ s /rotes Tenant Name: Name: Pled ef0I 14PQi1o1 Contact Person: ?"- 'apprraSoea'pamit applerooe (7 -2004) Building Permit No. Mechanical Permit No. /Y) O (o / 0 7 Public Works Permit No. Project14o. (Toro/Ike we only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print•• Wee I King Co Assessor's Tax No • g g y g7d00 id Floor: New Tenant: ❑ Yes Property Owners K Name Kov ROLJtt aJc nR r n / i 5 + UL Mailing Address: 4 tC 24 - ! (n Y t �S / Ii 4 4 ( a IkA. State Suite Number: City ❑..No 91W7 TUK VILA CONTACT PERSON t' or Day TelephoneX.6 ,Q Mailing Address: 1244 2 DOS 1 lw M 5 ton S D Y (,( k 9 $jinn City State E -Mail Address: Fax Number: .FJXr 3 13 '4 1 I GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor intormatlon on back page) Company Name: MO tP.t&n -tei _ Mailing Address: i�.yti2 1 tS f1ol run 1140-1 b City State Zip Day Telephone: 'No - a(ti 3 00 E -Mail Address: Fax Number: X (o - aq 3 -1344 Contractor Registration Number: CO . x.10 D RS p S 3QZ Expiration Date: 111131 ..An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance*• 1 ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record 1 Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number. State Zip I ENGINEER OF RECORD — All pons must be wet stamped by Engineer of Record 1 Company Name' Mailing Address: State City Contact Person: Day Telephone: E -Mail Address: Fax Number: Zip Unit Type: Qtv Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qtv Furnace- 100K BTU ( Air Handling Unit >10.000 CFM Fire Damper 0-3 HP /100.000 BTU Furnace - WOK BTU EvaporatorCooler Diffuser 3-15 HP /500.000 BTU Floor Furnace Ventilation Fan Thermostat 15-30 HP/ 1.000.000 BTU Suspended Vall,Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP 1.750.000 BTU Appliance Vent Hood Water Heater 50+ HP/ 1.750.000 BTU Heat RefrigCooling System Incinerator- Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator - Command Other Mechanical Equipment MECHANICAL PERMIT INFORMATION — 206- 431 -3670 MECHANICAL CONTRACTOR INFORMAT ON Company Name: `-� N2 A-L-K Mailing Address: f 2..-9 b 2 Dr A/1/1APES M ,z D Cal , APES 1D-r fad � WA- 4 t1 6 .e.- A-(-4-elf— _. City s6t Zip Contact Person: f W S Day Tel ne: 3 r700 E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: "An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance** Gj C �3 Valuation of Project (contractor's bid price): $ a I p y Scope of Work (please provide detailed information): Pc A - C--t 'i C.— G --A- -1 C c.r,,o..r Ilse: Residential: New .....0 Replacement 0 Commercial: New .... Replacement ❑ ): ueI Tyne: Electric ❑ Gas Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES — Applicable to all permits in this application Valve of Constriction -In all cases, • value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Pennit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILD . O R OR AUTHORIZED AGENT: Sianatu Print Name: \.wiicatwe. pemittppiwtim (7-2004) t - r G - L • Uja VI 5 Mailing Address: fAND- Dts,Nniws Mom .fie I Date Application Accepted: 0 WOe l / Pane 4 Day Telephone: -"Olt) ?k 3 -770 0 cirf-fic City Date: ,5'2LI I ht. State Zip Date Application Expires: / Staff lnitialq: 1 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 8849700010 Permit Number: M06-107 Address: 4822 S 164 ST TUKW Status: APPROVED Suite No: Applied Date: 06/02/2006 Applicant: HOUHAKNAMM /STEIGER RESIDENCE Issue Date: Receipt No.: R06 -00793 Payment Amount: 158.94 Initials: BLH Payment Date: 06/05/2006 02:20 PM User ID: ADMIN Balance: $0.00 Payee: GLENDALE HEATING AND AIR CONDITIONING RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 56785 158.94 ACCOUNT ITEM UST: Description MECHANICAL - RES Account Code Current Pmts 000/322.100 158.94 Total: 158.94 6094 06/05 9716 TOTAL 158.94 doc: Receipt Printed: 06 -05 -2006 LENNOX ENGINEERING DATA G a REGISTERED QUALITY SYSTEMS 0 Horizontal Configuration VERIFIED VERIFIE SureLighte Patented Hot Surface Ignition System Two Stage Control Board with Dlagnostk LED's MODEL NUMBER IDENTIFICATION aww Peromunce rree„er &,sgmpw Durables Aluminized Steel Heat Exchanger Primary Limit Control Factory installed Field Wiring Make -Up Box can be installed on either side Tool -Less Entry Blower speed changes at control board Terminals for Accessory Connections (powered ale cleaners and humidifiers) Low Voltage Circuit Breaker U H - Unit type T G = Gas Fumace A Series 60 = Two-Stage Elite 80% Configuration UN = Up-Flow /Horizontal Nominal Add-On Cooling Capacity 24 = 2 tons (7.0 kW) 36 = 3 tons (10.6 kW) 48 = 4 tons (14.1 kW) 60 = 5 Tons (17.8 kW) I Evaporator coils with the same letter designation will physically match the fumace. GAS FURNACES G6OUH ELITE® SERIES Up -Flow / Horizontal Two-Stage Heat AFUE - 80% Input - 66,000 to 132,000 Btuh Nominal Add-on Cooling -1.5 to 5 tons Bulletin No. 210350 October 2004 Supersedes July 2003 Or X L Low NO, = Units meet Califomia Nitrogen Oxides standards 1 Cabinet Width A = 14 -1/2 in. (363 mm) B = 17-1/21n. (445 mm) C = 21 in. (533 mm) D = 24-1/2 in. (622 mm) Visit us at www.lennox.com. For the latest technical Information, www.lennoxdavenetcom. Pressure Switch Heavy -Duty Transformer Combustion Air Inducer Combination Gas Control Valve Gas and electrical connections from either side of cabinet Aluminized Steel Inshot Bumers Direct Drive Slide -Out Blower Fully Insulated Blower Compartment Nominal Gas Heat Input (High Fire) 070 = 66,000 Btuh (19.3 kW) 090 = 88,000 Btuh (25.8 kW) 110 = 110,000 Btuh (322 kW) 135 = 132,000 Btuh (38.7 kW) RECBVED CITY OF TUKWILA JUN 02 2006 PERMIT CENTER NOTE - Due to Lennox' ongoing committrnent to quality, Specifications, Ratings and Dimensions subject to change without notice and without incumng liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal Injury. 02004 Lennox Industries Inc. Installation and service must be performed by a qualified Installer and servicing agency. Gas Model No. Heating Low NOx Model No. Performance High Fire Input - Btuh (kW) Output - Btuh (kW) G6OUH- 24A-070 - - - 66,000 (19.3) 54,000 (15.8) G6OUH-36A-070 G6OUH36A -070X 66,000 (19.3) 54,000 (15.8) G6OUH- 36B -090 - - - 88,000 (25.8) 72,000 (21.1) G6OUH-48B -090 G6OUH-48B-090X 88,000 (25.8) 72,000 (21.1) Temperature rise range - °F ( °C) 40 - 70 (22 - 39) 40 - 70 (22 - 39) 40 - 70 (22 - 39) 35 - 65 (19 - 36) Low Fire Input - Btuh (kW) 45,000 (13.2) 45,000 (13.2) 60,000 (17.6) 60,000 (17.6) Output- Btuh (kW) 36,000 (10.6) 36,000 (10.6) 48,000 (14.1) 49,000 (14.4) Temperature rise range - °F ( °C) 20 - 50 (11 - 28) 20 - 50 (11 - 28) 20 - 50 (11 - 28) 15 - 45 (8 - 25) 1 AFUE 80.0% 80.0% 80.0% 80.0% California Seasonal Efficiency 74.2% 73.9% 73.8% 74.6% High static (CSA) - in. w.g. (Pa) .50 (124) .50 (124) .50 (124) .50 (124) Connections Flue connection - round 4 (102) 4 (102) 4 (102) 4 (102) In. (mm) Gas pipe size IPS 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) Indoor Wheel nom dia. xwidth -in. (mm) 10 x 7 (254 x 178) 10 x 8 (254 x 203) 10 x 8 (254 x 203) 10 x 10 (254 x 254) Blower Motor output - hp (W) 1/5 (149) 1/3 (249) 1/3 (249) 1/2 (373) Tons(kW) ofadd-on cooling 1.5- 2(5.3 -7.0) 1.5- 3(5.3 -10.6) 2- 3(7.0 -10.6) 3- 4(10.6 -14.1) Shipping Data Ibs. (kg) -1 package 127 (58) 132 (60) 146 (66) 153 (69) Electrical characteristics 120 volts - 60 hertz -1 phase (less than 12 amps) Gas Model No. Heating Low NOx Model No. Performancs High Fire Input- Btuh (kW) G6OUH-36C -110 - - - 110,000 (32.2) G60UH -08C -110 - - - 110.000 (32.2) - - - G6OUH430C -110X 110,000 (32.2) G6OUH -00D -135 - -- 132,000 (38.7) Output - Btuh (kW) 90,000 (26.4) 90,000 (26.4) 90,000 (26.4) 108,000 (31.6) Temperature rise range - °F ( °C) 50 - 80 (28 - 44) 40 - 70 (22 - 39) 35 - 65 (19 - 36) 45 - 75 (25 - 42) Low Fire Input - Btuh (kW) 75,000 (22.0) 75,000 (22.0) 75,000 (22.0) 90,000 (26.4) Output - Btuh (kW) 61,000 (17.9) 60,000 (17.6) 61,000 (17.9) 73,000 (21.4) Temperature rise range - °F (°C) 25 - 55 (14 - 31) 20 - 50 (11 - 28) 20 - 50 (11 - 28) 25 - 55 (14 - 31) 1 AFUE 80.0% 80.0% 80.0% 80.0% California Seasonal Effidency 74.2% 75.0% 73.9% 74.9% High static (CSA) - in. w.g. (Pa) .50 (124) .50 (124) .50 (124) .50 (124) Connections Flue connection - in. (mm) round 4 (102) 4 (102) 4 (102) 2 4 (102) Gas pipe size IPS - in. (mm) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) Indoor Wheel nominal diameter x width 10 x 8 10 x 10 11 -1/2 x 10 11 -1/2 x 10 Blower - in. (mm) (254 x 203) (254 x 254) (292 x 254) (292 x 254) Motor output - hp (W) 1/3 (249) 1/2 (373) 1 (746) 1 (746) Tons (kW)of add-on cooling 2 -3(7.0 -10.6) 2.5- 4(8.8 -14.1) 4- 5(14.0 -17.6) 4- 5(14.0 -17.6) Shipping Data Ibs. (kg) - 1 package 166 (75) 169 (77) 175 (79) 195 (89) Electrical characteristics 120 volts - 60 hertz - phase (less than 12 amps) • SPECIFICATIONS SPECIFICATIONS NOTE - Filters and provisions for mounting are not furnished and must be field provided. 1 Annual Fuel Utilization Ewdency based on DOE bet procedures and acmdhg to FTC labeling regulations. Isolated combustion system rang for nonweatlwxbad furnaces. 2 Flue connection on are unit 4 4 k. (102 mm) diameter. Most applications WI mourn 5 h. (127 mm) venting and Ileld suppled 4 x 5 h. (102 x 127 mm) adaptor. See Venting Tables h the Installation Insbtcfone for detailed information. G60UH / Page 4 11 -01 -2006 GLENDALE HEATING, RITA WALTERS 12462 DES MOINES MEMORIAL DR SEATTLE WA 98168 RE: Permit No. M06 -107 4822 S 164 ST TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of for additional periods not exceeding 90 days each. Extension requests must be In writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 12/02/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, rshall, Permit Technician City of l u•la Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director xc: Permit File No. M06 -107 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 -431 -3665 License Information License GLENDHA053Q2 Licensee Name GLENDALE HEATING & A/C INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600003167 Ind. Ins. Account Id Business Type CORPORATION Address 1 12462 DES MOINES WY S Address 2 City SEATTLE County KING State WA Zip 981682266 Phone 2062437700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 11/22/1995 Expiration Date 11/2/2007 Suspend Date Separation Date Parent Company Previous License GLENDHOI IOPU Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HOEFER, ARTHUR A 01/01/1980 HOEFER, GERALD A 01/01/1980 FULTON, DAVID C 01/01/1980 ATWOOD, STANLEY AGENT 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 4r' Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= GLENDHA053Q2 06/05/2006 ✓. ". _ _ . . 4 _ 1 , 1 / ' 1 r � ��� w j ao'v". ��ww- �Gla�:. I*air'�,'7Nllr/•fd� >pQ GLENDALE OIL CO, INC 12462 DES IGOINES WAY S Dtlnch And Display ('crtilic:✓ — F625-052 (A/97) DEPARTMENT OF LABOR AND INDUSTRIES LICENSED AS PROVIDED BY LAW AS ELEC CONTR HVAC /RFRG LICENSE # EXP DATE EC6A GLENDHA003CM 02/14/2008 EFFECTIVE DATE 02/14/2000 GLENDALE HEATING & A/C 12462 DES MOINES MEMORIAL DR SEATTLE WA 98168 -2266 Detach And Display Certilicat 1 E625-052-000 (8/97) DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONS; CONT GENERAL w . . _.�•:.... :.. ........ .. __. _ REGIST'. # ` - EXP'. - DATE` . . CCO1 HGLENDHA053Q2 11102/2007.° EFFECTIVE "DATE" * 11`/22/1995 GLENDALE HEATING & A/C INC 12462 DES MOINES WY S SEATTLE WA 98168 -2266 Detach And Display Certificate