Loading...
HomeMy WebLinkAboutPermit M06-132 - BOEING #9-08.2BOEING #9 -08.2 9725 EAST MARGINAL WY S M06 -132 Parcel No.: Address: Suite No: City car' Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us 0003400018 9725 EAST MARGINAL WY S TUKW Tenant: Name: BOEING #9 -08.2 Address: 9725 EAST MARGINAL WY S, TUKWILA WA Owner: Name: THE BOEING COMPANY Address: PO BOX 3703 M/S #1F -09, SEATTLE WA Contact Person: Name: RAYNEE HALE Address: 1221 2 AV N, KENT WA Contractor: Name: HERMANSON COMPANY LLP Address' 1221 2ND AV N, KENT, WA Contractor License No: HERMACL005B3 DESCRIPTION OF WORK: RELOCATE EXISTING HEAT PUMP WITH ASSOCIATED DUCT WORK. Value of Mechanical: $2,500.00 Type of Fire Protection: SPRINKLERS Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended /Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System Air Handling Unit <10,000 CFM 1 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System O Hood and Duct 0 Incinerator: Domestic 0 Commerclal /Industrial 0 doc: IMC- Permit MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M06 -132 Phone: Phone: 206 -575 -9700 Phone: 206 -575 -9700 Expiration Date:08 /25/2006 Steven M. Mullet, Mayor Steve Lancaster, Director M06 -132 06/26/2006 12/23/2006 Fees Collected: $191.18 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 3 Thermostat 1 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment... 0 Printed: 06 -26 -2006 Permit Center Authorized Signature: doc: IMC- Permit City & Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: cttukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -132 Issue Date: 06/26/2006 Permit Expires On: 12/23/2006 Date: G — Zfa-b I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. sl Signatureg L a i-0 0 A Date: 4 1 a,0) Olo Print Name: h Qti This permit shall become null and void if the work Is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M06 -132 Printed: 06 -26 -2006 City drTukwila Parcel No.: 0003400018 Address: 9725 EAST MARGINAL WY S TUKW Suite No: Tenant: BOEING #9 - 08.2 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Conditions Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us PERMIT CONDITIONS * *continued on next page ** Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -132 Status: ISSUED Applied Date: 06/16/2006 Issue Date: 06/26/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 7: All electrical work shall be Inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. M06 -132 Printed: 06 -26 -2006 City car Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: cttukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any regulating construction or the performance of work. Signature: Print Name: Rai Ifet. - c doc: Conditions Steven M. Mullet, Mayor Steve Lancaster, Director of law and ordinances other work or local laws Date: lo r7 In [ p(0 M06 -132 Printed: 06 -26 -2006 Site Address: ,�^�_ � Tenant Name: Y't-t - a Property Owners Name: Mailing Address: `1. CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto: //www. ci. tukwila. wa. us Company Name: T LQ Qrbtip Mailing Address: °t en 1 44- 4 `et. p Mailing Address: Building Permit No. Mechanical Permit No. M 0 32— Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print *S SITE LOCATION ..t4 L et S. CONTACT PERSON Name: Retiree., T"(eat- Day Telephone: Q.CAD — 515 — 0 17130 Mailing Address: \ aA\ W'd Y C N . VQ at 1. I WW Q to a' City sta te , Zi E -Mail Address: �� ( P 1er YYIQYIbm • C—' - Om Fax Number: ra' ODD — 5 ` `/��l tco GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg S) ) _tut at Company Name: Mailing Address: \'aak Y' d Contact Person: 5CPne_. a `b o_br c ✓ E -Mail Address: Contractor Registration Number: Nr-gyr4Acu3o B Company Name: SQxne n ` m Q2 N e- Contact Person: E -Mail Address: o:Uppawion$Wmau- Applicefioes On Un vaaa6- Permit Applicatioe.dec Revised: 42006 bh King Co Assessor's Tax No.:f ria4akiDePlq. 0 tr b . Suite Number: eto 0 -� New Tenant: ❑ Yes Z.No 4Ze ni City State Zip cisict q to3a- State Zip City Day Telephone: Fax Number: Expiration Date: SI Qb1eA0 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Sects 412. l th.1\ Q MCc9 -F City State Zip Contact Person: Day Telephone:atil) — 1 - (o(1)0 E -Mail Address: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record State Zip City Day Telephone: 'Fax Number: Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM F Fire Damper 0-3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3-15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15-30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment MECHANICAL PERMIT INFORMATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMAT TIIO� ( N Company Name: t -P.i itla- ' &W) 1S 1 Mailing Address: 1 a ^ , ■ D. 1 - ,. t✓ IPriv - Contact Person: flPL Y 1 � �te E -Mail Address: YIYt IQ,e\ n� . 0 -Or r\ Contractor Registration Number: T F -nnei os aT Valuation of Project (contractor's bid price): S , y , M y Scope of Work (please provide detailed information): Q-CI oCC12It r jsH no f Ect Purr) t)\4% \ fl SSD60 clac; ioyl . 11,m Residential: New .... Replacement.... Commercial: New Replacement.... Fuel Type: Electric ❑ Gas....❑ Other: Indicate type of mechanical work being installed and the quantity below: Q1Applic.Oo .WPmme- Appliunane On IineU- 2006 -Permit Applice0on.doc Revised: 42006 bb Very+ vi P 4tosa- Day Telephone: 2t3.o 1 - § - L-0 CO !0 -< Fax Number: 10 15— G F )w Expiration Date: -**6 1 at 10 Page 4 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review— Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103,4.3 Uniform Plumbing code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN9nNER OR AUTHORIZED AGENT: Signature: Cl AA - o 0 o Print Name: e Mailing Address: t 1 an d • Date Application Expires: /1- /1.-c' b Date Application Accepted:, Q 1AppliwioMForm.•Applications On LinO3 -2006 • Pamit Application.doc Revised 4-2006 .. bb Date: b t o I t)(1) Day Telephone: — 51 5 - q-j 60 dent c SO '3 - City State Zip Staff Initials: Page 6 of 6 1 ACCOUNT ITEM LIST: Description City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0003400018 Permit Number: M06 -132 Address: 9725 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 06/16/2006 Applicant: BOEING #9 -08.2 Issue Date: Receipt No.: R06 -00930 Payment Amount: 191.18 Initials: BLH Payment Date: 06/26/2006 01:16 PM User ID: ADMIN Balance: $0.00 Payee: HERMANSON COMPANY TRANSACTION LIST: Type Method Description Amount Payment Check 1623 191.18 MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Account Code Current Pmts 000/322.100 158.94 000/345.830 32.24 Total: 191.18 6919 06/26 9716 TOTAL 191.19 doc: Receipt Printed: 06 -26 -2006 P giect: /3 7 - is -z Type of Inspection: A-,,,. / Address: 9" 72 r £ / 4/ Date Called: Special Instructions: Date Wflnte : o - G (. a.m: p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION COMMENTS: PERMIT 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 1aApproved per applicable codes. E1 Corrections required prior to approval. 58.00 REINSPE9TION FEE RF,QUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Bl , Suite 100. Call to sechedule reinspection. Receipt No.: 'Date: Pr ect: �- !seiwVL 9 -os - 7_ Type of Inspection: RA" AI- •kv Address: 92725 5 /11440 .17/8/ Date Called: Special Instructions: _ Z hi 4 /r)2 l F/ Date Wanted: ze-UG a.m P.m. eg uester: Phone No: / 9 06 6/7 - &27o 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: o 2y 4 - kfiv ��>�r•� -/M G — 43/4 aa• — Lo—� .00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: ACTIVITY NUMBER: M06 -132 DATE: 06 -16 -06 PROJECT NAME: BOEING #9.08 -2 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: I�G Iv Boritng uivision Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete M Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 2 Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2-28-02 PLAN REVIEW /ROUTING SLIP oe d PERMIT COORD COPY Structural Incomplete Approved with Conditions 010 auk- (ta Fire Prevention ❑ Permit Coordinator No further Review Required DATE: DATE: Planning Division C DUE DATE: 06 -20-06 Not Applicable ❑ DUE DATE: 07 -18-06 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License HERMACL005BJ Licensee Name HERMANSON COMPANY LLP Licensee Type CONSTRUCTION CONTRACTOR UBI 602004844 Ind. Ins. Account Id PARTNER/MEMBER Business Type LIMITED LIABILITY COMPANY Address 1 1221 2ND AVE N Address 2 City KENT County ICING State WA Zip 980322945 Phone 2065759700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/11/2000 Expiration Date 8/25/2006 Suspend Date Separation Date Parent Company Previous License HERMAC•217NT Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HERMANSON, RICHARD L PARTNER/MEMBER 01/01/1980 ALMON, KEVIN PARTNER/MEMBER 01/01/1980 MACDONALD, JAMES PARTNER/MEMBER 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= HERMACL005BJ 06/26/2006 24/16 24/12 —, 20/16 2725 SECOND FLOOR HVAC PLAN - E SCALE: 1 f8 f -0 COFFEE NOOK 1 224 JA OFFIC 2239 \ 14110 2725 1010 V/ . 400 20/16 20/16 24/12 (21C8) 2 10 EXIT CORRIDOR 24'10 FD2 16x12 9O*ELBOW W/ OPEN TOP 24,,E 5/4 2750\ 22/16 SG 5 x a 2750 40 22/16 20/16 20/16 24 12 . X1 0 4 , 400 H�2FI > :E (GENERAL) 14i OFF1C 24/16 24/12 400 .v, • L, T -1-2- S_ - -- -- 1F2 F� \HP1J 400 • • No changes shall is min to the amps cf work without Ate' approval of Tukwila Building Milos. NOTE: Revisions will require a new plan subs and may include additional pion review SEPARATE REQUIRED lIORb Citsftwiall Ireectikal gwla O ins Ipq �r d li/� BUILDING DIVISION dq► of Woo.. oNNISIMINImimm mac MINIM OP =MB ....•.. ONO MI el UMW I ' 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: ---- EQUIPMENT NUMBER FOR MAINTENANCE & LABEL. EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. 2. N GENERAL NOTES SYMBOL FOR.,:;,, TYPICAL. 3. DUCTWORK SWAY BRACING NO. 18 GA. DUCTILE WIRE. MINIMUM ONE BRACE PER DUCT BRANCH. MAXIMUM SPACING 40 FEET. CONSTRUCTION NOTES RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY CHANGES FROM THE DESIGN. MOON WONG, 655 -8428, M/C 46-87 IOW FABRICATE AND INSTALL SE,Cl,IBIIY GRILLE WITH ACCESS DOOR ON THE EXISTING DUCTWORK. ,SEE DRAWING M527 FOR THE DETAIL. (2 PLACES). FABRICATION AND INSTALLATION OF THE SHEET METAL DUCTWORK SHALL CONFORM TO THE SMACNA STANDARD. CONNECT TO EXISTING DIFFUSER. RELOCATE EXISTING DUCT AND DIFFUSER. PROVIDE PRIMARY AIR CONNECTION TO HEAT PUMP. 6 RELOCATE THERMOSTAT. CAP EXISTING DUCT. go■ R.> EXTEND 20x16 BY 2' AND CONNECT TO EXISTING. imps" Rimit No. No -13 itouval coribudion dooming due not adheres d approved Field Coq at mtllas b adraAlfi1t ate /al ciSgIc City of "UAW BUILDING OINjSi011 LOCATE TO CLEAR DIAGONAL BRACING SECTION �1 1/tr=1'-0' �Y11 LEGEND: RECEIVED NAY 1 8 2006 ODERA1. CONSTRuL Ti' i CO BOBI a SCUM OFFS 1S EXISTING WALLS NEW FULL - HEIGHT PARTITION DEMOUNTABLE PARTITION FURNISHED AND INSTALLED BY OWNER PROGRAM PERIMETERS AND STC 45 PARTITION STC 45 PARTITION STC 50 PARTITION SECURITY BAR WITH 8X8 ACCESS DOOR. ■ 111 tvlou - �3z SCALE 1; 8' =1 -0' DLR Group 8' 4' 0 4' 8' 16' Architecture Engineering Planning loaners 7 SECURE E ..411_ LOCATE TO CLEAR WAIN irwIN COW. Now 175 OFFIC 14 10 10 10 24/16 AFSD 24/12 20 /16 20/16 24/10 FD2 725 400 280 280 T CORRIDOR 16x12 90'ELBOW w/ OPEN TOP 415FERENCE CD 400 2750 L L ENCE 200 ir ERENCE or B z PJ 2000 22/16 20/16 24/12 400 2000 24/16 AFSD 120 SCALE: 1 j8= 1 = -0: COFFEE NOOK 1 224 SECOND FLOOR HVAC PLAN — 5 JA • 400 24/16 24/12 10/10 O 400 '4/10 \ HP1 / N 2 W2-7 } • c9) SECTION ,nr -r-o• DIAGONAL BRACING F-22 E7tPN0M B ULDING 9- 1 SECOND FIOOR HVAC PLMI LEGEND: EXISTING WALLS NEW FULL — HEIGHT PARTITION DEMOUNTABLE PARTITION FURNISHED AND INSTALLED BY OWNER PROGRAM PERIMETERS AID STC 45 PARTITION STC 45 PARTITION STC 50 PARTITION SECURITY BAR WITH 8X8 ACCESS DOOR. _. III _.WIN - MI ....O 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: :II: EQUIPMENT NUMBER FOR MAINTENANCE & LABEL. EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. 2. E SYMBOL FOR GENERAL NOTES 3. DUCTWORK SWAY BRACING NO. 18 GA. DUCTILE WIRE. MINIMUM ONE BRACE PER DUCT BRANCH. MAXIMUM SPACING 40 FEET. REMOVAL NOTES RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY CHANGES FROM THE DESIGN. MOON WONG, 655-8428, M/C 46-87 REMOVE DIFFUSER AND DUCT TO THIS LOCATION, RETAIN FOR REINSTALLATION 2' TO THE NORTH. REMOVE HEAT PUMP, RETAIN FOR REINSTALLATION. I> REMOVE DUCTWORK. °EV. D FLOOR D FLOOR REMOVAL TYPICAL. • JOB ND. MC WI 0 . KEY PLAN No SCALE RECEIVED war i s 4/06 MEOWED CITY OF TucvMaa► JUN { s zoo jSS77O4OO SNIT DLR Group Mchisecure Engineering mss B 2M11R 1 9—(e -2111 COUP IND. 05.12.06 0 ; ji • Mk 0 6 vv , j" - - � 816 WAIN irwIN COW. Now 175 OFFIC 14 10 10 10 24/16 AFSD 24/12 20 /16 20/16 24/10 FD2 725 400 280 280 T CORRIDOR 16x12 90'ELBOW w/ OPEN TOP 415FERENCE CD 400 2750 L L ENCE 200 ir ERENCE or B z PJ 2000 22/16 20/16 24/12 400 2000 24/16 AFSD 120 SCALE: 1 j8= 1 = -0: COFFEE NOOK 1 224 SECOND FLOOR HVAC PLAN — 5 JA • 400 24/16 24/12 10/10 O 400 '4/10 \ HP1 / N 2 W2-7 } • c9) SECTION ,nr -r-o• DIAGONAL BRACING F-22 E7tPN0M B ULDING 9- 1 SECOND FIOOR HVAC PLMI LEGEND: EXISTING WALLS NEW FULL — HEIGHT PARTITION DEMOUNTABLE PARTITION FURNISHED AND INSTALLED BY OWNER PROGRAM PERIMETERS AID STC 45 PARTITION STC 45 PARTITION STC 50 PARTITION SECURITY BAR WITH 8X8 ACCESS DOOR. _. III _.WIN - MI ....O 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: :II: EQUIPMENT NUMBER FOR MAINTENANCE & LABEL. EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. 2. E SYMBOL FOR GENERAL NOTES 3. DUCTWORK SWAY BRACING NO. 18 GA. DUCTILE WIRE. MINIMUM ONE BRACE PER DUCT BRANCH. MAXIMUM SPACING 40 FEET. REMOVAL NOTES RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY CHANGES FROM THE DESIGN. MOON WONG, 655-8428, M/C 46-87 REMOVE DIFFUSER AND DUCT TO THIS LOCATION, RETAIN FOR REINSTALLATION 2' TO THE NORTH. REMOVE HEAT PUMP, RETAIN FOR REINSTALLATION. I> REMOVE DUCTWORK. °EV. D FLOOR D FLOOR REMOVAL TYPICAL. • JOB ND. MC WI 0 . KEY PLAN No SCALE RECEIVED war i s 4/06 MEOWED CITY OF TucvMaa► JUN { s zoo jSS77O4OO SNIT DLR Group Mchisecure Engineering mss B 2M11R 1 9—(e -2111 COUP IND. 05.12.06 0 ; ji • OFFICE CO CO y 3" HPWS " 3 HPWR ktI tE2, CO 1 "ID CO HFR3 t U12 ■ of2, I OPEN I I II OPEN « co y 2ei Q Upl 4 1 ".ID HPWR HPWS 2" HPWR 2" HPWS H 1" ID 3" HPWR 3" HPWS " ID OR/1M 101105 1001.,90 07.14.04 CROUP ER 0512.011 3 3'HPWR NIMES SSE sTr SEE DETAIL 2M62 M523 Co COI 2. CO 2"HPWS 2'HPWR 2 2 1/2' ID HPWS HPWR /2" ID ID <22e1, WS 12 COFFEE N WOK HPWR ON 224 1 1/ w O CL w @NdtPwR R00r HPWS co I 22C8 r .L HPWR HPWS EXIT CORRIDOR T T ■ __ CONFLRENCE 1 1/4" HPWR 1 1/4" HPWS 11 WOMEN CORRIDOR CO I 22811 CO 1 1/4" HPWR 1 1/4' HPWS JAN STOR T 8" HPWS UP & 6 ON 12" HPWS UP J 6 HPWR 6" HPWS � r 22C10> CTWS a , WOMEN SHETI • ELECTRICAL RM —if WOMEN 1 21D13 111 SECOND FLOOR PIPING PLAN - B ---gatm-A-7176. 22VATCH LINE (FOR CONTINUATION SEE 2" ID (21D13) 1"ID TO S. SINK N COI=F H 2�D9 1 1 /4" H PWR 1 1 /4 HPWS CO CO 2" HPWS 2" HPWR CO 4" HPWR 1" ID 1 " ID 4" HPWS OPEN OFFICE I Cj j � 1" ID 1 1/2" ID OPEN OFFICE rAh:€ } ,/2' !D 3" HPWR 3" HPWS 3" HPWS 3" HPWR 3'HPWS 3 "HPWR O HEET 2M63) l H H }- OLAIPArE7Allir tiFY9. 1P2, HP2E13 i I 22E9 I 21E10 J 21E11 CONFERENCE 21E12 tiP2 CONFERENCE I 22E12 I4CCEP'*IIBU1'Y 114 X901 ZIT SPE�11 6 IEO APPROVED R TOWL ir nom 4" RWL DN. - wpm 1 F. MOM IL WNW E'er Mom W. HEMEL - krWEy 12 REMOVAL NOTES D:::;:3P REMOVE HEAT PUMP, CAP ID, HPWR AND HPWS. STORE AND MAINTAIN FOR RELOCATION AND REINSTALLATION AS INDICATED ON SHEET 2M61. • 4 REMOVAL SECOND FLOOR PING PLNI r -n EXPANSION BULDING 9.082 Von r. LEGEND: EXISTING WALLS NEW FULL - HEIGHT PARTITION DEMOUNTABLE PARTITION FURNISHED AND INSTALLED BY OWNER PROGRAM PERIMETERS AND STC 45 PARTITION STC 45 PARTITION STC 50 PARTITION GENERAL NOTES 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: EQUIPMENT NUMBER FOR MAINTENANCE & LABEL. EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. ( 't a • Receive) ow 18 se ett._colisTRuc,_ro t co NumE scup' wiz AA 0(0 - ice .. KEY PLAN MO SCALE 8' 4' G 4' 8' SCALE: 1/8"=1 RECEIVED cn'v OF TUKWILA } U M i S 200 PER , : CFkr -; i ■ DLR Group Architecture 45577W-OG 05.12.06 2M61R � - - - - _ •► -.