HomeMy WebLinkAboutPermit M06-133 - QDOBA MEXICAN GRILLQDOBA MEXICAN GRILL 150 ANDOVER. PK W M06 -133 Parcel No.: Address Suite No: doc: IMC- Permit City G.? Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us 0223000020 100 ANDOVER PK W TUKW Owner: Name: MUSTANG L L C Address: P O BOX 88162, SEATTLE WA Contractor: Name: CFM HEATING AND COOLING INC Address: PO BOX 82360, KENMORE WA Contractor License No: CFMHEHC969CD Value of Mechanical: $27,568.00 Type of Fire Protection: SPRINKLERS Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall /Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig/Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial /Industrial MECHANICAL PERMIT Tenant: Name: QDOBA MEXICAN GRILL Address' 100 ANDOVER PK W, SUITE 130, TUKWILA WA Contact Person: Name: BRAD DUVALL Address: 4865 WARD RD, SUITE 500, WHEATRIDGE CO DESCRIPTION OF WORK: INSTALL DUCT WORKS, HVAC UNITS FOR NEW RESTAURANT, ADD IN ONE TYPE -1 HOOD AND ANSUL SYSTEM AND WALK -IN- COOLER. EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 2 0 0 0 3 0 1 0 0 **continued on next page** M06 -133 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 720 -898 -2360 Phone: 425 -481 -6239 Expiration Date:02 /04/2008 Boiler Compressor: 0 -3 HP /100,000 BTU 3 -15 HP /500,000 BTU 15 -30 HP /1,000,000 BTU 30 -50 HP/1,750,000 BTU 50+ HP/1,750,000 BTU Fire Damper Diffuser Thermostat Wood /Gas Stove Water Heater Emergency Generator Other Mechanical Equipment Steven M. Mullet, Mayor Steve Lancaster, Director MO6 -133 08/04/2006 03/19/2007 Fees Collected: $477.03 International Mechanical Code Edition: 2003 4 Printed: 09 -27 -2006 Permit Center Authorized Signature I hereby certify that I have read and x ordinances governing this work will governing this work will b Signatur Print Name: doe: IMC- Permit City alp Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: cttukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -133 Issue Date: 08/04/2006 Permit Expires On: 03/19/2007 Date: m f ` t ait inedlthis permit and know the same to be true and correct. All provisions of law and i d with, whether specified herein or not. The granting of this permi • • es not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construct' • performance of work. I am authorized to sign and obtain this mechanical permit. Date: This permit shall become nu and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M06 -133 Printed: 09 -27 -2006 Parcel No.: Address: Suite No: CITY OF TUKWILA DEPT. OF Co!.,1,UIITY DEVELOPMENT 6300 CGUTH :ENTER CLVD. TUKWILA, WA 98188 0223100010 150 ANDOVER PK W TUKW Tenant: Name: QDOBA MEXICAN GRILL Address: 150 ANDOVER PK W, TUKWILA WA Owner: Name: GIBSON PROPERTIES LLC Address: 401 ANDOVER PARK E, TUKWILA WA Contractor: Name: CFM HEATING AND COOLING INC Address: PO BOX 82360, KENMORE WA Contractor License No: CFMHEHC969CD Value of Mechanical: $25,568.00 Type of Fire Protection: SPRINKLERS Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall /Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT Contact Person: Name: BRAD DUVALL Address: 4865 WARD RD, SUITE 500, WHEATRIDGE CO DESCRIPTION OF WORK: INSTALL DUCT WORKS, HVAC UNITS FOR NEW RESTAURANT, ADD IN ONE TYPE -1 HOOD AND ANSUL SYSTEM. EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 2 0 0 0 3 0 1 0 0 * *continued on next page ** doc: IMC- Permit M06 -133 PERMIT CENTER Permit Number: Issue Date: Permit Expires On: Phone: Phone: 720 - 898 -2360 Phone: 425 -481 -6239 Expiration Date:02 /04/2008 M06 -133 08/04/2006 01/31/2007 Fees Collected: $453.98 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU 30 -50 HP /1,750,000 BTU 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 24 Thermostat 1 Wood /Gas Stove 0 Water Heater 1 Emergency Generator 0 Other Mechanical Equipment Printed: 08-04 -2006 Permit Center Authorized Signature: Permit Number M06-133 Issue Date: 08/04/2006 Permit Expires On: 01/31/2007 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws This permit shall become null an void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. regulating construction or t • -- •'•rmanc - tr•rk. I am authorized to sign and obtain this mechanical permit. Signature: -t _ Date: U 1p `q-0(e, Print a X` irtly doc: IMC-Permit M06-133 Printed: 08 -04 -2006 red DEFT CF C.........1: 1 1." ' l.:-NT 691 ,J �U i'r N LR GLVD. TUKWILA, WA 98188 PERMIT CONDITIONS P i�thva Y i,Sfl tij Parcel No.: 0223100010 Permit Number: M06 -133 Address' 150 ANDOVER PK W TUKW Status: ISSUED Suite No: Applied Date: 06/16/2006 Tenant: QDOBA MEXICAN GRILL Issue Date: 08/04/2006 1: ***FIRE DEPARTMENT CONDITIONS "` 2: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 3: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire- extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) 4: An approved automatic fire- extinguishing system is required for this project. 5: All new automatic fire- extinguishing systems and all modifications to existing automatic fire- extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 6: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 7: "'FIRE ALARM SYSTEMS*** - City Ordinance #1900 - NFPA 72 8: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 9: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main retum -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 10: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 11: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 12: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 13: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 14: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #2051) 15: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) doc: Conditions M06 -133 Printed: 08- 04-2006 16: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 17: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Conditions **continued on next page** M06 -133 Printed: 08 -04 -2006 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Conditions Date: 8 —q ev::, M06 -133 Printed: 08 -04 -2006 SITE LOCATION Site Address: 160 ANDDt/S(t PARK tl.t)€6T Tenant Name: fvo$A 'hoc re A n/ `aigT" / Property Owners Name: Mailing Address: CONTACT PERSON Name: BRAD Thsv l r t_ Day Telephone:_72 - frig-23 C f0 Mailing Address: 1 41 1 5(2s - IA) A RD RED Ab Stint SDo IAA H EAr I'D &.F CO Roo City State Zip Fax Number: 120 - S9/3 -2 1&, E -Mail Address: KDyeni_r Q add, . f./1 GENERAL CONTRACTOR INFORMATION — (Contractor information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) ) Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWILA,.; Community Developmen Department Publk Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: /hvww. cr tkwila. wa. us LA) t c- 1 or- l SC 23'-1 cr1 R S 'o✓rH 6o nta W$ City State Day Telephone: 20 6 _a 11 Fax Number: 4 is 7 7 q MATT Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print" Le-5s ftaffee -o[ 1 -oCC to. scf- ue1ioed .lgr.7 Contractor Registration Number: Vs.)) L C° t # l9 1-1 QO ARCHITECT OF RECORD - All plans must be wet stamped by Architect otRecord Company Name: L- rient.E btst6N &ttou i 1No• Mailing Address: MSa. Lott- M 4 Ley ST' Contact Person: RAI & A R L E- E -Mail Address: t`A.ve,aWPJ Lin &p tSn - LDM ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: RV E 4GTIyr E R.TN4 t TNG 2t3& . !' ! r+ Mailing Address: ! VV LT,TE( AA.. g Jr'( '-/ sr/1ir/j Contact Person: V +J: E -Mail Address: Q tApplicationsTonns- Applicafions On line \3 -2006 - Permit Application.doc Revised 4 -2006 bh Building Perin�tt` j7 - 2%. Mechanical Permit No. MO t2- !33 Plumbin Permit No. P - cob Public Works Permit No. Project No. }ROO- o&6 (For office use only) W TUKWILA W King Co Assessor's Tax No.: 830711.0 Suite Number: Floor: New Tenant: Q Yes ❑..No City FAbt City Day Telephone: Fax Number: State Expiration Date: / / O/ Zip 9sa2D Zip 11 2c C/oSIB State Zip etc-a:449 -car SIS 169 g4q9C W � 7 State Zip City Day Telephone: at* - 704 - 9'4 44_ Fax Number: 206. 706- [RR(' Page 1 of 6 BUILDING PERMIT INFORM ION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ r /t0 2 ,56 p Existing Building Valuation: $ Scope of Work (please provide detailed information): acg- Will there be new rack storage? ❑ .. Yes 2...No (If yes, a separate permit and plan submittal will be required) Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ .... Yes ❑ ..No If eyes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0.. Automatic Fire Alarm ❑..None ❑ -Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes 14.. No !f "yes", attach list of materials and storage locations on a separate 8 -1/2 x !1 paper indicating quantities and Material Safety Data Sheets. SEPTIC SYSTEM: 0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q AApplicationsWmms- Applications On Line\3.2006 - Permit Application.doc Revised'. 4-2006 bh Compact: Handicap: Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC t °Floor 2.170 2" Floor 3r Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORM ION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ r /t0 2 ,56 p Existing Building Valuation: $ Scope of Work (please provide detailed information): acg- Will there be new rack storage? ❑ .. Yes 2...No (If yes, a separate permit and plan submittal will be required) Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ .... Yes ❑ ..No If eyes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0.. Automatic Fire Alarm ❑..None ❑ -Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes 14.. No !f "yes", attach list of materials and storage locations on a separate 8 -1/2 x !1 paper indicating quantities and Material Safety Data Sheets. SEPTIC SYSTEM: 0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q AApplicationsWmms- Applications On Line\3.2006 - Permit Application.doc Revised'. 4-2006 bh Compact: Handicap: Page 2 of 6 (PUBLIC WORKS PERMIT IN1/4 — 206 - 433 -0179 Scope of Work (please provide detailed information): Water District ...Tukwila 0... Water District #125 ❑...Water Availability Provided Sewer District ❑ ...Tukwila ❑...Sewer Use Certificate ❑ ...Total Cut ❑ ...Total Fill Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑... ValVue 0... Sewer Availability Provided Eubmitted with Application (mark boxes which apply): ...Civil Plans (Maximum Paper Size -22 "x34 ") ❑...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Pro sed Activities mark boxes that a 1 : ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way cubic yards cubic yards ❑...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ ...Traffic Control ❑ .. Looped Fire Line ❑...Backfow Prevention - Fire Protection Irrigation Domestic Water ❑...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size o ...Sewer Main Extension Public Private ❑ ...Water Main Extension Public Private Q:\ApplicationsWmsns- Applications On IineV -2006 - Permit Application doc Revised 0.2006 bh Call before you Dig: 1- 800 -424 -5555 ❑ .. Highline ❑ .. Renton ❑ .. Seattle ❑ .. Approved Septic Plans Provided ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ .. Renton ❑ .. Right -of -way Use - Profit for Tess than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size ❑...Traffic Impact Analysis ❑...Hold Harmless — (SAO) ❑...Hold Harmless — (ROW) FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑...Water ❑...Sewer ❑...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Day Telephone: Mailing Address: City State Zip Page 3 of 6 Unit Type: Qty Unit Typ Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU .. Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater ` 50+HP /1,750,000BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM n v Incinerator - Comm/Ind Other Mechanical Equipment MECHANICAL PERMIT INFORMATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ 25 5 (. Scope of Work (please provide detailed information): ay,- r )101 - •-.) tJ - \ - W f f P e V-QiS 144- R-4a —r t 1 A - OD 1 J k '1 CR- \-1C" O V Pr 1-1•0 A-tJ Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ....V Replacement .... ❑ Fuel Type: Electric V Gas.... Other: Indicate type of mechanical work being installed and the quantity below: Q ApplicationsWorm,- Applications On Line \3 -2006 - Permit Application doc Revised 4-2006 bh Page4of6 1 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Q 8 Bidet Food -waste grinder, commercial Receptor, indirect waste _�MEW11S S Ntie –Tim re Njf.KEP FLOD2 s to/ I L L D Clothes washer, domestic Floor drain 3 Sinks Dental unit, cuspidor Shower, single head trap Urinals 1 Dishwasher, domestic, with independent drain Lavatory Water Closet Z /l� &t AAt&.rnTEPt4$Tt Building sewer or trailer park sewer Rain water system – per drain (inside building) Water heater and/or vent Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Additional medical gas inlets/outlets – six or more PLUMBING AND GAS PIPIN Q'Upplicetiau \Forms - Applications On LineV -2006 - Permit Applicamn.doc Revised. 4 -2006 bh ERMIT INFORMATION — 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: State Contact Person: E -Mail Address: Contractor Registration Number: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quan ity below: City Day Telephone: Fax Number: Expiration Date: Zip Valuation of Project (contractor's bid price): $ 2 8 (1C,5 Scope of Work (please provide detailed information): eArt4 PLC) > t a 6 n 1--- C-6 r\M u- e— I A r o-N I N c, l . A tS )4 .�A-V N ,u2 . G (4:4_6.- 5 r1z It e 7_ re- -b ^ S G f R C - o a t &J1-PM Page 5 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Perini( The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).. Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A AGENT: Signature: / �^ � Date: a Print Name: b-4 ?" t-r ' L'- C'S A Mailing Address: 2 'S - I Datc Application � t S Q:UpplimtionsWmmn•Appliudmu ee LSd3•2006 • Mmit Appliwion.doc Revixd: 4-2006 bh Day Telephone: !� EbMa r City W ft sate Date Application Expires: Page 6 of 6 City of Tukwila Parcel No.: 0223000020 Permit Number: M06 -133 Address' 100 ANDOVER PK W TUKW Status: ISSUED Suite No: Applied Date: 06/16/2006 Applicant: QDOBA MEXICAN GRILL Issue Date: 08/04/2006 Receipt No.: R06 -01517 Payment Amount: 23.05 Initials: JEM Payment Date: 09/27/2006 08:52 AM User ID: 1165 Balance' $0.00 Payee: GARY WIRTA 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 TRANSACTION LIST: Type Method Description Amount RECEIPT Payment Cash 23.05 ACCOUNT ITEM LIST: Description Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES Account Code 000/322.100 18.44 000/345.830 4.61 Total: 23.05 0170 09/27 9716 TOTAL 23.05 doc: Receipt Printed: 09 -27 -2006 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223100010 Permit Number: M06 -133 Address: 150 ANDOVER PK W TUKW Status: APPROVED Suite No: Applied Date: 06/16/2006 Applicant: QDOBA MEXICAN GRILL Issue Date: Receipt No.: R06 -01186 Payment Amount: 369.18 Initials: BLH Payment Date: 08/04/2006 10:45 AM User ID: ADMIN Balance: 80.00 Payee: EXPRESS CONSTRUCTION TRANSACTION LIST: Type Method Description Amount Payment Check 029024 369.18 ACCOUNT ITEM LIST: Description Current Pmts MECHANICAL - NONRES RECEIPT Account Code 000/322.100 369.18 Total: 369.18 E 51 08/04 0716 TOTAL 669:68 doc: Receipt Printed: 08-04 -2006 �U� RECEIPT NO: R06 -00883 Initials: BLH Payee: WILCOX CONSTRUCTION INC SET TRANSACTIONS: Set Member Amount ,D06 -232 1,084.98 M06 -133 ' 84.80 PG06 -068 54.50 TOTAL: 1,224.28 city of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 SET RECEIPT Payment Date: 06/16/2006 User ID: ADMIN Total Payment: 1,224.28 SET ID: 5000000506 SET NAME: Tmp set/Inidalized Activities TRANSACTION LIST: Type Method Description Amount Payment Check 63102 1,224.28 TOTAL: 1,224.28 ACCOUNT ITEM LIST: Description Account code Current Pmts PLAN CHECK - NONRES 000/345.830 1,224.28 TOTAL: 1,224.28 6374 36/1? ?"'16 TOTAL 1224.28 Steven M. Mullet, Mayor Steve Lancaster, Director P II Project: (J�ol )�l Type of Ins ection: p Ok'i V Address: Date Called: 0 Special Instructions: Date Wanted: 072112 p.m. Requester: Phone No: G J INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 ®Approved per applicable codes. COMMENTS: P er _/ ( le to /�� riev Date: 03 0 Receipt No.: !Date: INSPECTION RECORD Retain a copy with permit Corrections required prior to approval. 8.00 REINSPECTION F REQUIR . Prior to inspection, fee must be paid at 6300 Southcenter :hid., Suite 100. Call to sechedule reinspection. Project:: // 'MIN LL (7 Type of Inspection: 774../ /a Address: /UC.> !fin derVerPte lti Date Called: Special Instructions: Date Wanted: j = 2 7 O ( `p.m Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITE OF TUKWILA BUILDING DIVISION 6300 Southcenter 8Ivd., #100, Tukwila, WA 98188 (206)431 -3620 Approved per applicable codes. • Corrections required prior to approval. COMMENTS: p , 4 c t oil Pottf-/ Oen/ /ey -- gopladvte /Dew F /t Ali 0/+/ F A50 / IOa r a9 -01 8.00 REINSPECTION FEE REQUIR Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: 'Date: COMMENTS: e,.Ae o + 1j 20 ; A, - II Type of In� on: / n/ i t Y Du 1 k1C4 C �"y to r t. V �� ` (� 1. /y 7.., u.p..,.f..a MQo*J4 - 60,.., f 1E-1! L J w.a1i -e 4L ber.nJ — Cw.. t c i t f l ,L, G e WI' 000(k cr in \A (— Ng.1.131 � Special Instructions: V" Q 2 V C-, r e yen" Date Wanted: Za -ot ate. Requester: Proje�,t� Z S 4,4 J CI Y'i Type of In� on: / n/ Address: An JVr, �� 1� l ,L, Date Called: Special Instructions: V" Q 2 V C-, r e yen" Date Wanted: Za -ot ate. Requester: Phone CIte 1 9 - 2, N Approved per applicable codes. Ins ..motor: (Receipt No.:\ INSPECTION RECORD Retain a copy with permit INSPE' ION NO. CITY • F TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 !Date: Corrections required prior to approval. ! 9 (a (24. .00 REINSPECTION F REQUIRED. Pri¢ to inspection, fee must be id at 6300 Southcenter : vd., Suite 100. all to sechedule reinspection. Project: m 7/5 -71/1A1 Le 1 COMMENTS: / n !- / / / e I A �s d /l�•� T� iesihstur . Address: /O p »N ,,.,z P /-r 7Ln on/ / "is , isn O n- z/ev. 74 Special Instructions: Date Wanted: � /fr-# k.. � tt4ri4 ✓ / "rev (G- Requester: Avs-e 7 9e.s7 Aaoc/ Phone No: z/ 5 r Skt,fAw,t. tea-/ S /2.0.3 ,r.- .07104/ /�T -- A/ f ' / ,) -- ,R1- ,` x a-7 Project: m 7/5 -71/1A1 Le Type of Inspection: " / Address: /O p »N Date Called: �'''' Special Instructions: Date Wanted: la,tti: Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPE ON NO. PE CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 06)43 b3 El Approved per applicable codes. R ceipt No.: Date: 00 REINSPECTION FEE R; • U!RED. to inspection, fee must be td at 6300 Southcenter Blvd Suite 1 0 .. Call to sechedule reinspection. Corrections required prior to approval. Project: 021/s /44 L L C Type of Inspection: \ hie-1 .1_vs Address: /00 s94/O01/t: a r' 4 41 Date Called: Special Instructions: Date Wanted: CJ -Z s 06 P.m. Requester: Phone No: a -,570 -/2 C INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 CNksisplkoved per applicable codes. INSPECTION RECORD Retain a copy with permit (206)431 -367 Corrections required prior to approval. " COMMENTS: / r 4 . der et 14/14 -- Ala a cV Ins p S5 pa I Recei t No.: H 'Oat, Z 0 REINSPECTION FEE EQUIRED. Pri to inspection, fee must be at 6300 Southcenter Blvd., Suite 100 Call to sechedule reinspection. Date: Projec ' '�-- /��� Type of Inspect on: �� d).-7 Address: /a* A- 10V6.) Date d Special Instructions: Date Wanted: Requester: Phone No: -1.5 - 1 /7T.4 INSP[CTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 D Approved per applicable codes. INSPECTION RECORD Retain a copy with permit 0 • )431 -3¢7 Corrections required prior to approval. COMMENTS: p A _ 4 V - ` $58.00 REINSPECT! dSl FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedute reinspection. Receipt No.: 'Date: 02 -02 -2007 BRAD DUVALL 4865 WARD RD, SUITE 500 WHEATRIDGE CO 80033 RE: Permit No. M06 -133 100 ANDOVER PK W TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writine and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 03/28/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: Permit File No. M06 -133 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 June 20, 2006 Brad Duvall 4865 Ward Rd, Ste 500 Wheatridge, CO 80033 RE: Letter of Incomplete Application # 1 Mechanical Permit Application M06 -133 Qdoba Mexican Grill —150 Andover Pk W Dear Mr. Duvall: This letter is to inform you that your application received at the City of Tukwila Permit Center on June 16, 2006 is determined to be incomplete. Before your application can continue the plan review process the follwoing items from the following department(s) need to be addressed: Building Department: Ken Nelsen, at 206 431 -3677, if you have any questions concerning the following comment. 1. Separate plans required for mechanical scope of work Please address the above comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail. If you have any questions, please contact me at the Permit Center at (206) 433 -7165. Sincerely, arshall unit`fethnician Enclosures File: Permit M06 -133 City of Tukwila Department of Community Development Steve Lancaster, Director 0,4ao P:Uenniferincomplete Letters \2006\ivt06 -133 Incomplete Ltr #1.DOC Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite 11100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 `� PERMIT COORD COPY `- PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M06 -133 DATE: 07 -13 -06 PROJECT NAME: QDOBA MEXICAN GRILL SITE ADDRESS: 150 ANDOVER PK W Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEP RTMENTS: 41190 Build' Di ision Public Works REVIEWER'S INITIALS: REVIEWER'S INITIALS: Documentshouting slip.doc 2-28-02 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete d Incomplete ❑ Comments: DATE: DATE: Planning Division Permit Coordinator TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required DUE DATE: 07-18-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 08-15-06 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: beis PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M06 -133 DATE: 06 -16 -06 PROJECT NAME: QDOBA MEXICAN GRILL SITE ADDRESS: 150 ANDOVER PK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: / � B i ding ivision f 4 `p gf Public Works ❑ Complete ❑ Comments: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2-28-02 Fi re Prevention I Structural DETERMINATION OF COMPLETENESS: (Tues., Thuys.) Incomplete TUES/THURS ROUTING: Please Route El Structural Review Required REVIEWER'S INITIALS: Approved with Conditions❑ flu �L teem- F Planning Division ❑ Permit Coordinator No further Review Required DATE: DATE: C DUE DATE: 06-20-06 Not Applicable ❑ Permit Center Use Only ( INCOMPLETE LETTER MAILED: W (U 6 di LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: n DUE DATE: 07-18-06 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ? Z7- o, ❑ Response to Incomplete Letter # Tr Response to Correction Letter # V vision # after Permit is Issued vision requested by a City Building Inspector or Plans Examiner Project Name: Vb$A Protect Address: %Op Anaouou- «PCfr W Contact Person: Phone Number: 1 5` Yet - .W71 Summary of Revision: W41' M rodeJr' tick ai ;ea I Vat ZioW _cc) Created: 8 -13 -2004 Revised: raw City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Fax: 206431 -3665 Web site: http: //www.ci.tukwilawa.us Received at the City of Tukwila Permit Center by: IS Entered in Permits Plus on \applications\ forms - applications on line revision submittal Steven M. Mullet, Mayor Steve Lancaster, Director Plan Check/Permit Number: Mob -13? t)11b orrummut SEP 2 7 2006 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision Including date of revisit) Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7 -13 -06 City of Tukwila V Response to Incomplete Letter # _ ❑ Response to Correction Letter # ❑ Revision # ^ after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Odoba Mexican Grill Project Address: 150 Andover Park West Tukwila, WA 98188 Contact Person: Jim Marlow Summary of Revision: Mechanical Re- Submittal Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: /�I�OV19nBW� Entered in Permits Plus on 1 7 4a7 pplications orris- applications 011 line\revision submittal Created: 8 -13 -2004 • Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Plan Check/Permit Number: M06-133 Phone Number: (720) 898 -2367 Steven M. Mullet, Mayor Steve Lancaster, Director RFCPIWIN CITY OF TUKWILA JUL 1 3 2006 PERMIT CENTER License Informatlon License CFMHEHC969CD Licensee Name C F M HEATING AND COOLING INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602361244 Ind. Ins. Account Id #1 Business Type CORPORATION Address 1 PO BOX 82360 Address 2 City KENMORE County KING State WA Zip 98028 Phone 4254816239 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/4 /2004 Expiration Date 2/4 /2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Bond Informatlon Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #1 RLI INS CO 5RS1008639 02/04/2004 Until Cancelled 512,000.00 02/04/2004 Business Owner Information Name Role Effective Date Expiration Date CLANCY, SHAUN PRESIDENT 02/04/2004 Look Up a Contractor, Electric; an or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Savings Information https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= CFMHEHC969CD 08/04/2006 • MECHANICAL CRITERIA' 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS FOR A COMPLETE MECHANICAL SYSTEM AS INDICATED ON AND DESCRIBED N THE CONTRACT DOCUMENTS. CONTRACTOR SHALL BID AND INSTALL ALL WORK N ACCORDANCE SETH THE LANDLORD'S CRITERIA AND CONSTRUCTION STANDARDS. SUI3NIISSICN OF A BD ACKNOWLEDGES THIS CONTRACTOR HAS OBTAINED AND REVIEWED ALL OF THE LANDLORD'S REQUIREMENTS N THE PROPOSAL. FOR WORK. VERIFY ALL OF THE 04S1NG CONDITIONS AT THE SITE PRIOR TO SUBMITTING A BID. REVIEW ALL ARCHITECTURAL, STRUCTURAL, ELECTRICAL AND PLUMBING DRAWINGS. REVIEW ALL INSTRUCTIONS TO BIDDERS. GENERAL CONDITIONS AND PROJECT MANUAL SUBMISSION OF A BID MALL. ACKNOWLEDGE THAT THIS CONTRACTOR HAS VISITED THE PROJECT SITE MD COMPLETED A THOROUGH RENEW OF SHE CONTRACT DOCUMENTS. CONTRACTOR SHALL REQUEST CLARIFICATION TO ANY DISCREPANCIES WHICH MAY EXIST IN THE CONTRACT DOCUMENTS PRIOR TO BID. ABSENCE OF ANY REQUEST WALL ACKNOWLEDGE CONTRACTOR UNDERSTANDS ALL REQUIREMENTS OF THE DOCUMENTS, METHODS OF INSTALLATION AND MATERIALS TO BE USED. WHERE ITEMS HAVE NOT BEEN REQUESTED FOR CLARIFICATION PRIOR TO THE BID, THE MOST STRINGENT REQUIREMENTS MALL APPLY. 2. HVAC WORK SHALL COMPLY WITH THE WEST EDITION OF THE BOCA MECHANICAL CODE AS WELL AS GOVERNING STATE AND LOCAL CODES. 3. PAY FOR ALL REQUIRED PERMITS AND INSPECTIONS AND PROVIDE A CERTIFICATE OF INSPECTION. 4. FIVE (5) COPIES OF ALL SHOP OR EQUIPMENT DRAWINGS SHALL BE SUBMITTED BY THIS CONTRACTOR THESE DRAW NGS SHALL BE CLEARLY MARKED INDICATING VIHK21 ITEMS ARE TO BE SUPPLIED AND SHALL STATE CAPACITIES, SIZES. REQUIRED INSPECTION LABELS AND GENERAL DESCRIPTIONS OF ALL EQUIPMENT AND FIXTURES 5. THIS CONTRACTOR SHALL GUARANTEE ALL EQUIPMENT AND MATERIAL INSTAIJ.ED UNDER THIS CONTRACT TO BE FREE FROM DEFECTS FOR A PERIOD OF ONE YEAR FROM DATE Of FINAL ACCEPTANCE AND SHALL REPAIR OR REPLACE NTHOUT COST TO THE OWNER MY EQUIPMENT WHCH IS DEFECTIVE. OR IMPROPERLY INSTALLED. IN ADDITION, THIS CONTRACTOR SHALL ASSUME FULL RESPONSIl31UTY FOR ANY DAMAGE TO THE BUILDING AND ITS CONTENTS OR OTHER EQUIPMENT CAUSED BY DEFECTS OR IMPROPER NSTALLAT1ON OF EQUIPMENT OR MATERIALS INSTALLED UNDER THIS SECTION OF THE SPECIFICATIONS. 6. FABRICATE AND INSTALL GALVANIZED SLEET METAL DUCTWORKC FOR VELOCITIES LESS THAN 2000 FEET PER MINUTE AND STATIC PRESSURES LESS THAN 2' WATER GAUGE IN ACCORDANCE WL1H THE LATEST EDITION OF SHE 'LOW VELOCITY DUCT CONSTRUCTION STANDARDS' POLISHED BY THE SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION. INC. (SMACNA). ALL ELBOWS AND BRANCHES FROM MAIN N ALL SUPPLY AND RETURN DUCTS SHALL BE PROVIDED WA1H IURNNG VAF.S. A. ALL RECTANGULAR SUPPLY AND RETURN AIR DUCTWORK SHAH BE INSULATED SETH 1/2' COATED FIBERGLASS DUCT UNER - 2 PCF DENSITY INSULATION. DUCT SIZES SHOWN ON DRAWINGS FOR THIS DUCTWORK ARE SHEET METAL SIZE AND INCLUDE INSULATION. B. MAKE -UP AIR AND ROUND SUPPLY AIR DUCTWORK SHALL BE INSULATED MATH 1 -1/2" MINERAL FILLER BLANKET - 1 PCF DENSITY INSULATION. DUCT SIZES SHOWN ON DRAWINGS FOR THIS DUCTWORK ARE SHEET METAL SIZE. C. WELDED GREASE EXHAUST DUCTS FROM TYPE 1 HOODS SHALL BE INSULATED SETH 2 LAYERS OF 1 -1/2' awl FIR MASTER FIRE WRAP. DUCT SIZES SHOWN ON DRAWINGS ARE SHEET METAL SIZE. D. INSULATED FUMBLE DUCT SHALL BE SHE RUAFLEX TYPE MK -E 7. TEST AND ADJUST ALL AIR HANDING EQUIPMENT TO PROVIDE THE REQUIRED AR VOLUME AGAINST THE SYSTEM STATIC PRESSURE. TEST AND SET ALL DAMPERS AND SUPPLY, RETURN AND EXHAUST DEVICES TO CFL SHOWN ON THE DRAWINGS. PROVIDE ALL REQUIRED SHEAVE AND BELT CHANGES REQUIRED TO OBTAIN CM QUANTITIES SHIOW1 ON THE DRAWINGS TESTING AND BALANCING SHALL BE W ACCORDANCE WITH PROCEDURES OUAJNED IN TESTING AND BALANCING MANUAL AS PUBUSHED BY SMACNA. 8. FURNISH AND INSTALL ALL MECHANICAL EQUIPMENT AND AIR DEVICES AS SCHEDULED ON THE ORAVNGS. PROPOSALS SHALL BE BASED ON THIS EQUIPMENT AND NO SUBSTITUTIONS WILL BE ACCEPTED. 9. REFRIGERANT IDES SHALL BE HARD DRAWN COPPER TUBE; TYPE 1 -ACR". WITH WROUGHT COPPER RUNGS. ALL JOINTS SHALL BE BRAZED VAIN SILFOS OR EQUAL. FURNISH AND INSTALL A UQUID UNE SIGHT GLASS AND DRIER - STRAINER AS MANUFACTURED BY SPORLAN OR EQUAL INSULATE CANT SUCTION LINES AND CONDENSATE LINES WITH r FOAM PLASTIC ARMAFLEX OR EQUAL ALL REFRIGERANT INSULATION INSTALLED ON OUTSIDE PIPING SHALL BE COATED WITH 2 COATS OF UV RATED WATERPROOFING COMPOUND. NO CONCEALED JOINTS WILL BE ACCEPTABLE. 10. NATURAL GAS PWNG SHALL BE SCHEDULE 40 BLACK STEEL WITH MALLEABLE RON SCREENED FITTNGS FOR PIPE SIZES SMALLER THAN 3' AND STANDARD VA3G HT WELD FITTINGS FOR PIPE SIZES 3" AND LARGER. INSTALL GAS COCK DIRT LEG, UNION AND POUNDS - RICHES REGULATOR (F REQUIRED) WHIN 6' -0' OF EACH EQUJIPIENT CONNECTION. ALL GAS PIPING LOCATED OUTDOORS SHALL BE PAINTED WITH RUST INHIBITOR PANT. SEISMIC RESTRAINTS SHALL BE REQUIRED IN ACCORDANCE VAIN THE 1996 BOCA NATIONAL CODE MATH THE NOTED EXCEPTIONS. GAS LINE SHALL BE TESTED AT TWICE THE OPERATING PRESSURE AND MUST HOW WIHOUT LOSS OF PRESSURE FOR 24 HOURS 11. CONDENSATE PIPING SHALL BE TYPE IC HARD DRAWING COPPER COPPER ANTS SHALL BE MADE WAIN 50-50 SOLDER PIPING SHALL BE PITCHED N THE DIRECTION OF FLOW W1H A PITCH OF 1' IN 10. ALL CONDENSATE PIPING SHALL BE INSU LAITD NTH 1/2' THICK CLOSED CELL ARMAFIFX IISUAITEON. 12 MECHANICAL CONTRACTOR SHALL PRO TOE TEMPERATURE CONTROL LIMNING AS PART OF THIS 1EIDRK. ALL SYSTEMS SHALL BE COMPLETE INCLUDING ALL REQUIRED EQUIPMENT, RELAYS, SNITCHES. CONTACTORS AND f .ECTRICAL WIRING EXPOSED N RETURN MR PLENUM SHALL BE PLENUM RATED CABLE 13. PACKAGED ROOFTOP UNIT WITH GAS HEATNG, SPACE THERMOSTAT SHALL ENERGIZE DE COOLING CRCUT TO SATISFY COOING DEMANDS AND SHE GAS VALVE IHROUGII ITS SAFETY CONTROLS TO SATISFY HEATING DEMANDS TIE O OWNER SHALL RUN CONTINUOUSLY AND SHE OUTSIDE MR DAMPER SHALL OPEN FOR A PRESET AMOUNT OF VENTILATION WIENN N OCCUPIED MODE SPACE THERMOSTAT SHALL BE A TYPE SILLAR TO HONEYWELL '17300 14_ EXHAUST FANS 1T -1 AND EF-2 SHALL BE INSERIOCIGFD W1H THE LHGHTMG CIRCUIT. EF -3 SHALL RUN CONTIMIOUSLY_ 15. DISABLE ECONOMISER N ORDER TO AOC RAIELY BMANCE SYSTEML • • GENERAL HVAC NOTES 1 SHE FOLLOWING NOTES APPLY TO ALL MECHANICAL DRAWINGS. ADDITIONAL MECHANICAL NOTES MAY BE INDICATED ON EACH MECHANICAL DRAYANG. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 2 REFER TO ARCHITECTURAL AND STRUCTURAL. DRAWINGS FOR GENERAL CONSTRUCTION INCLUDING LOUVERS, CONCRETE EQUIPMENT PADS, FLASHING DETAILS, ETC. 3 REFER TO ARCHITECTURAL DRAWING FOR ROOM ELEVATIONS LOCATE MECHANICAL DEVICES SUCH AS TEMPERATURE SENSORS. HUMIDISTATS, PANELS, ETC. SO THAT THEY DO NOT CONFUCT SETH GENERAL CONSTRUCTION (WAINSCOT. DOOR HARDWARE, ETC.) NOR VATH ELECTRICAL. SYSTEM (UGHT SNITCHES, SPEAKERS, OUTLET'S. ETC.). MOUNT THERMOSTATS 48' AFF UNO. 4 MECHANICAL DRAWINGS SHOW APPROXIMATE LOCATIONS FOR GRILLES AND DIFFUSERS. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF GRILLES, REGISTERS, DIFFUSERS. AND OTHER COUNG OR SURFACE MOUNTED DEVICES. INSTALL EQUIPMENT N CONFORMANCE WTH ARCHITECTURAL FEATURES IN SHE CENTER OF CEIUNG TIES. N 111E CENTER OF ROOMS. OR %INHERE INDICATED ON ARCHITECTURAL DRAAANGS. WHERE EQUIPMENT IS NOT INDICATED ON ARCHITECTURAL DRAWINGS. OBTAIN DIRECTION FROM ARCHITECT PRIOR TO INSTALLATION. 5 SEE ARCH. DRAWINGS FOR EXACT SIZE AND LOCATION OF LOUVERS. COORDINATE EXACT SIZE OF ATTACHED DUCT110RK/1tENUM AND /OR MOTORIZED DAMPERS WITH ARCH. DRAMNVGS. 6 GENERALLY DUCTWORK PLANNED TO BE TIGHT TO STRUCTURE WAIN PIPING BELOW DUCTWORK AND BETWEEN LIGHT FIXTURES. ADJUST AS NECESSARY. 7 COORDINATE LOCATIONS OF MECHANICAL EQUIPMENT AND DUCTWORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES FOR REMOVAL AND SERVICE ACCESS DUE TO EQUIPMENT MAINTENANCE. 8 ARRANGE HVAC EQUIPMENT SO THAT ACCESS CLEARANCES INDICATED BY DRAWINGS, REQUIRED BY CODES AND RECOMMENDED BY MANUFACTURER ARE PROVIDED. PROVIDE 42' CLEAR AT DISCONNECT SWITCH ON TERMINAL UNITS WITH ELECTRIC HEATING COIL 9 PROVIDE ACCESS PANELS/DOORS IN DUCTWORK AS INDICATED 111 DIVISION 15 FOR INSPECTION AND MAINTENANCE FOR ALL SMOKE/FIRE DAMPERS 10 GENERAL CONTRACTOR TO PROVIDE ACCESS TO FERE AND /OR COMBINATION FIRE/SMOKE DAMPERS THROUGH ACCESS DOORS N HARD COMICS AND WALLS. WHERE ACCESS DOORS PENETRATE FIRE RATED SYSTEMS THEY SHALL BE RATED N ACCORDANCE NTH IBC REQUIREMENTS. 11 REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL CHARACTERISTICS OF MECHANICAL EQUIPUENT (VOLTAGES. ETC). 12 DUCTWORK AND PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM ACCESS OF 6' IF RUNNING PARALLEL AND ABOVE CABLE TRAYS, AU.OW 18' TO THE SIDE OF CABLE TRAYS. 13 ELECTRICAL CHARACTERISTICS OF USED EQUIPMENT SHALL BE VERIFIED BY CONTRACTOR DURING SUBMITTAL PROCESS. ANY ELECTRICAL CHARACTERISTICS THAT DEVIATE FROM THOSE USED SHALL BE IDENTIFIED BY THE CONTRACTOR, SUBMITTED TO DE ENGINEER FOR APPROVAL AND COORDINATED WITH DIVISION 16 PRIOR TO INSTALLATION OF EQUIPMENT AS REQUIRED TO PROPERLY SERVE EQUIPMENT. 14 DRAWNGS ARE SCHEMA1)C N SOME AREAS AND MAY NOT SHOW OFFSETS M ICH MAY BE REQUIRED. PROVIDE OFFSETS AS REQUIRED AT NOT ADDITIONAL COST. 15 REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FH1NGS. VALVES, ETC. FLOOR PLANS AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND GENERAL PIPE ROUTING ONLY. 16 DUCTS AND PIPES INDICATED VATHOUT DIMENSIONS SHALL BE SIZED PER PRECEDING UPSTREAM DUCT AND PIPE SECTIONS. 17 DUCTWORK SIZES SHOWN ARE CLEAR INSIDE DIMENSION. 18 PROVIDE FABRICATED STEEL. MEMBER SUPPORTS AS REQUIRED BY MANUFACTURE R'S INSTALLATION INSTRUCTIONS, AS INDICATED ON DRAWINGS, OR N SPECIFICATIONS FOR INSTALLATION OF EQUWIENT. REQUIRED STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE w 1Ht AMEPJCAN INSTITUTE OF STEEL CONSTRUCTION (MSC) MANUAL 19 F REQUIRED FOR INSTALLATION OF PIPES, DUCTS, AND EQUIPMENT, PROVIDE ADEUONAL STRUCTURAL MEMBERS SEMEN COLUMNS, JOISTS, AND STRUCTURAL FRAME TO MEET SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. 20 00 NOT CORE DRILL OR DRILL THROUGH BEAMS. COLMAANS` AND SHEAR WALLS, UNLESS INDICATED ON STRUCTURAL DRAWNGS OR AS APPROVED BY THE STRUCTURAL ENGINEER. 21 PROAADE DUCT LNINNG FOR SHE FOLLOWNG DUC1WORIC: A. DGIAUST ouct 1DR1C FROM EACH OWAUIST GRILLE TO A PONT 10 FT UPSTREAM OF THE GRILLE (EXCEPT FOR KITCHEN AND SHOWER DGIAUST DUCT RTC). B. ALL MR TRANSFER DUCTS AND COUNG RELIEF GRILLES. C. ALL EXHAUST DUCTWORK WTHMV 15' OF A FAN (OCCEPT KITCHEN AND SHOWIER EXHAUST). D. ALL SUPPLY AND RETURN DUCTWORK WJ1IN 15' OF A FAN. E. ALL ENDED AN AND EXHAUST AR PLENUMS. DO NOT LINE OUTDOOR AIR PLENUMS F. PLENUMS UPSTREAM OF RETURN FANS. G. OTHER LOCATIONS WHERE NOTED ON ORAWNGS OR SPEC/RED 22 PROVIDE A VOLUME DAMPER FOR EACH SUPPLY BRANCH, RETURN BRANCH (DUCTED ONLY), & °M UST BRANCH VMERE THREE OR MORE OPENINGS ARE ASSOCIATED W1H SHE BRANCH, AND ELSEWHERE AS NOTED oN DRAWNGS OR N SPECIFICATIONS 23 PROVIDE OOMCAL SPIN-IN FITTINGS FOR ALL 90 DEGREE ROUND DUCT BRANCHES FROM RECTANGULAR SUPPLY DUCTWORK. DO NOT USE STRAIGHT TEE RUNGS. 24 DUCTWORK STATIC PRESSURE AND SEAL CLASS, BASED UPON SMACNA: 25 REFER TO WASHINGTON STATE NREC COMPLIANCE REQUMEMENTS ON CRAVING SCHEDULE SHEETS FOR ADDITIONAL MECHAMCAL PRO'AStONS 26 ECONOMIZERS SHALL MODULATE OUTSDE AIR FROM MMIMAUN TO 1002 PER WSEC 1413.1 27 SEAL DUCTWORK PER WSEC 1414.1 AND PER pISION 15 SPECIFICATIONS. 28 BALANCE HVAC SYSTEM PER WSEC 141&3 AND PER EVASION 15 SPECEfICATIONS 29 COMMISSON HVAC SYSTEM PER %MC 1416.4 AND PER OMSiONN 15 SPECIFICATIONS. 30 PROVIDE COMPLETION/RECORD DRAWINGS PER NSEC 1416 AND PER DIVISION 15 SPECIFICATIONS 31 DEM STATS SHALL BE INTERLOCKED TO PREVENT SIMULTANEOUS HEATING AND COOLING PER MSEC 1422, WISEC 1435. 32 INSULATE DUC1NORIC PER WSEC TABLE 14-5 AND PER DIVISION 15 SPECIFICATIONS (1MHIIC Ew R 6 GREATER). 33 RISIJLAE PEEING PER IIMC, TABLE 14-6 AND PER DIVISION 15 SPECIFICATIONS ( ECHE R IS GREATER). 34 PATCH ALL FLOOR. WAIL, CITING AND ROOF OPENINGS CREAMED/CAUSED BY THE OINOUTlON OF E SING DUCTS, PIPES, FIXTURES, ETC N ACCORDANCE N1H OMS10N 1 SPECIFICATIONS. 35 COORDINATE DEMOUIIOII NORK WA1H ARCHITECTURAL DEIOUIION AND PHASING GRATINGS 36 COORDINATE ALL IEQIAHIGIL WORK 1111TH AROITECTURAL PHASING C RMINGS 37 PATCH Ail FLOOR EVIL, CEILING AND ROOF OPENINGS CREATED/CAUSED BY THE OEMOU110N OF EXSTa1G OM% PIPES, FIXTURES, ETC N ACOCRDMICE WJH DEMON 1 OF THE SPEOFTCATIONS 38 REFER TO AR TEfRAIIMAL SCHEDULE FOR NET AND OUTLET DUCT SIZES UNLESS INDICATED ON FLOOR PEAL • ABBREVIATIONS AC AD AFC AFF AFG AHU AL BOO IWC BHP BI BOD EITU BTUH CO CFO CV CH CRD DIA DIM DIAPR DN DP DWG EX EAT EF EFF EG ELEC FH FARENNEIT FD FIRE DAMPER RR FLOOR FPM FEET PER MINUTE FSK FOIL SKRNM KRAFT LINED DUCT (SPUQSIRAND) FT FEET. FOOT G GAS GR atILLE HP HORSE POWER HR HOUR HTG HEALING HVAC HEATING, VENTILATION AND AIR CONDIIIONNG HW HOT WATER INFO NSUL JAN JANITOR MR CONDIAONNG ACCESS DOOR ABOVE FINISHED CEIUNG ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM BACK DRAFT DAMPER BELOW FINISHED CEILING BRAKE HORSE POWER BACKWARD INCJNED BOTTOM OF DUCT BRITISH THERMAL UNIT BRITSH THERMAL UNIT PER HOUR CUBIC FEET PER MINUTE CLEAN OUT CONSTANT VOLUME COLD WATER OE0.WG RADIATION DAMPER DIAMETER DIMENSION DAMPER DOWN DIFFERENTIA. PRESSURE ERASING OOSTING ENTERING ASR TEMPERATURE EXHAUST FAN EFFICIENT, EFFICIENCY EXHAUST GRILLE ELECTRICAL INSIDE DIMENSION INCH, INCHES INFORMATION INSULATE, MSULA110N KW KILOWATT KW 1 KILOWATT FLOUR LAT LF LVG MA MBH MAT MAX TECH MFG MED MIN MSC LEAVING ASR TEMPERATURE LINEAL FEET LEAVING MDED ASR THOUSAND BRITISH THERMAL UNITS PER HOUR MDED AIR TEMPERATURE MECHANICAL MANUFACTURER MEDIUM YiiI1lIY, MINUTE MISa LLANEOUS N NA NTS OSA OAT OD OPP OV PD PERT PF PH QTY RA REQD RET RG RPM SA SCHED SD SF SFD 5.1.0. SHT SP SPEC SR SS STAT TEMP 1D TEMP THIRD ISTAT TYP UL UV UMC UP V VAC w VAC VAV VEL VOL W/ W/O WB WIC WT NORTH NOT APPLICABLE NOT TO SCALE OUTSIDE NR OUTSIDE AIR TEMPERATURE OUTSIDE DIMENSION OPPOSE OUTLET VELOCITY PRESSURE DROP PERFORATED PRE FILTER PHASE QUANTITY RETURN MR REQUIRED RETURN RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SCHEDULE SMOKE DETECTOR SUPPLY FAN SMOKE/RRE DAMPER SUPPLED AND INSTALLED BY OWNER/ (OTHER) SHEET STATIC PRESSURE SPECIFICATION SUPPLY REGISTER STAINLESS STEEL THERMOSTAT TEMPERATURE TEMPERATURE DIFFERENTIAL TEMPORARY THROUGH THERMOSTAT TYPICAL UNDERWRITER'S LABORATORY UNIT VENTILATOR UNIFORM MECHANICAL CODE UNIFORM PLUMBING CODE UNIFORM BUILDING COOE VOLT voLIS AC VOLTS DC VOLUME DAMPER VACCUM VARIABLE AR VOLUME VELOCITY VOLUME WITH WITHOUT MET BULB WATER CLOSET WATER TANK WEIGHT • i SiaantaiS No changes shall be made to the scope of icrk without prier approval of Tukwila a Building Olviaion. NOTE: Revis cns w'.3 r iie a new plan subratt l and may Inckide additional plan review fees. SEPARATE PERSIST REQUIRED FOR: City of Tukviiia WILDING DIVISION • DRAWING SYMBOLS O NORTH ARROW SECTION IDENTIFICATION SHEET IDENTIFICATION GENERAL MECHANICAL NOSES NUMBER IDENTIFICATION FLAG MECHANICAL NOTES NUMBER IDEN11F1CATION SHEET INDEX I1.0 SYMBOLS, NOTES & ABBREEAATIONS M1.1 MECH. EQUIPMENT SCHEDULES 111.2 GAS PIPING ROOF DETAILS 112.0 MECHANICAL FLOOR PLAN M2.1 MECHANICAL ROOF PLAN M3.0 CAPTIVE AR HOOD DETAILS M3.1 CAPTIVE AIR HOOD DETAILS M3.2 CAPTIVE MR HOOD DETAILS oopr Pen* No. 3 Ulan rev*" approval Is abject to errors and a1at1 Applwa_ cf rarest: on documents does not aulmotda violaMi C.., appfc.z Dom: City of lirkwila BUILDING DIVISION HV Engineering, Inc. Consulting Engineers O 7100 Linden Ave. N. Suite O Seattle, Washington. 98103 wow. w. hvengineering. biz Phone: (206) 706 -9669 Paz: (206) 71)d -I890 EF-9 MECHANICAL LEGEND SYMBOL DESCRIPTION N 0 0 40r ..." 12a + + I' vsFD cRo + m e? _.___RS tipti" TERMINALS RL REUSE OF DOOMS DOSING WORK OR BACKGROUND INFORMATION (LIGHT UNE) NEW WORK (HEAVY LINE) RELOCATE D05TIriG EQUIPMENT ITEM OR DEICE NDICAIED DOSING EQUIPMENT OR DUC110311K TO BE SELECTIVELY DEMOLISHED TYPICAL EQUIPMENT DESIGNATION (EXHAUST FAN SHOWN) CARBON MONOXIDE (CO) SENSOR CO2 SENSOR OCCUPANCY (CO2) SENSOR ROOM THERMOSTAT (I) DUCT (1ST FIGURE = S1OE SHOW+, 2ND FIGURE = SIDE NOT SH01W) FLDOB[E CONIEC110N ACOUSTIC DUCT VOLUME DAMPER 45' TAKE-OFF 1g; F ANGULAR TAKE -OFF WI111 FLEXIBLE DUCT War p �� p K1R TOWARD 00*1 O AWAY USI DUCT Mk WNW DUCT URNNG UP TOWARD � I DO T IMI OR AWAY INCLINE D CHIN E IOM► ( N tr •.% M 3.% PallEW ROUND DUCT OR PHASE INDICATOR BACKORAFT DAMPER MOTORIZED DAMPER COMBINATION SMOKE/FIRE DAMPER CEILING DIFFUSER OR GRILLE RADIATION DAMPER FIRE DAM (FD) SMOKE DAMPER (SD) 90' ELBOW, R/MM OR R/b = 1.5 WARE NI1H V AI�ES OW 90' CONICAL SPIN-t1 F ILM& 0 WYE FITTING 90' OIVERGIIG RECTANGULAR EIIMIER RAORNS CR IUR SIC WilES CITING MISER, TYPE SE BALANCE TO 350 CFY FLOW ARROWS WWI ONLY F AR ROW 6 NOT 5 M ILIIRICA1. BMAINCE TO 360 CfM� IONIZATION TYPE SMOKE DETECTOR UNDER CUT DOOR 3/4' REFRIGERANT SUCTION LIME REFRIGERANT LIQUID LINE C CONDENSATE PIPING AK OOOIJIDIT. • UE: >DEI1S NID t MOS OICORPORMED ICOR AS MIN l SOMENT OF PROITSSIONAL SERMCE. IS NC PROPERTY OF IN ONNIEERING, NC: MD IS PIOT TO EE USED. 11 moil OR MI MT. FOR NIT OVER PROJECT TMCUT AE w017EN WRIORIZA11011 OF WI OEIEDIies. O IMOIT, ITV 131011031111G. INC LTR )MP' ETE FIECIEWIED CITYOF JU! FPI PERMiT VERA' SCALE em MEASURES oIE RCM ON COMM. MAIM Cr 1� 1 noT CIE NCR CR a CRAM[,. PONST SAS ACCOICRIGLIC 152 W. Main 5t. Lena, 1L 61048 P: (81 5) 369 -9 155 f: (81 5) 369 -4495 J J f 2 U X w 2 Ptou. eeo.: 06W -055 I 05/ 1 6/06 I SHEET NCR M1.O 150 ANDOVER PARK WEST TUKWILA, WA 98188 REVISIONS DESCRIPTION ■ S, NOTES V1ATIONS I } N91 agoti 0 - I F9CJG 1 Gas • MECHANICAL CRITERIA' 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS FOR A COMPLETE MECHANICAL SYSTEM AS INDICATED ON AND DESCRIBED N THE CONTRACT DOCUMENTS. CONTRACTOR SHALL BID AND INSTALL ALL WORK N ACCORDANCE SETH THE LANDLORD'S CRITERIA AND CONSTRUCTION STANDARDS. SUI3NIISSICN OF A BD ACKNOWLEDGES THIS CONTRACTOR HAS OBTAINED AND REVIEWED ALL OF THE LANDLORD'S REQUIREMENTS N THE PROPOSAL. FOR WORK. VERIFY ALL OF THE 04S1NG CONDITIONS AT THE SITE PRIOR TO SUBMITTING A BID. REVIEW ALL ARCHITECTURAL, STRUCTURAL, ELECTRICAL AND PLUMBING DRAWINGS. REVIEW ALL INSTRUCTIONS TO BIDDERS. GENERAL CONDITIONS AND PROJECT MANUAL SUBMISSION OF A BID MALL. ACKNOWLEDGE THAT THIS CONTRACTOR HAS VISITED THE PROJECT SITE MD COMPLETED A THOROUGH RENEW OF SHE CONTRACT DOCUMENTS. CONTRACTOR SHALL REQUEST CLARIFICATION TO ANY DISCREPANCIES WHICH MAY EXIST IN THE CONTRACT DOCUMENTS PRIOR TO BID. ABSENCE OF ANY REQUEST WALL ACKNOWLEDGE CONTRACTOR UNDERSTANDS ALL REQUIREMENTS OF THE DOCUMENTS, METHODS OF INSTALLATION AND MATERIALS TO BE USED. WHERE ITEMS HAVE NOT BEEN REQUESTED FOR CLARIFICATION PRIOR TO THE BID, THE MOST STRINGENT REQUIREMENTS MALL APPLY. 2. HVAC WORK SHALL COMPLY WITH THE WEST EDITION OF THE BOCA MECHANICAL CODE AS WELL AS GOVERNING STATE AND LOCAL CODES. 3. PAY FOR ALL REQUIRED PERMITS AND INSPECTIONS AND PROVIDE A CERTIFICATE OF INSPECTION. 4. FIVE (5) COPIES OF ALL SHOP OR EQUIPMENT DRAWINGS SHALL BE SUBMITTED BY THIS CONTRACTOR THESE DRAW NGS SHALL BE CLEARLY MARKED INDICATING VIHK21 ITEMS ARE TO BE SUPPLIED AND SHALL STATE CAPACITIES, SIZES. REQUIRED INSPECTION LABELS AND GENERAL DESCRIPTIONS OF ALL EQUIPMENT AND FIXTURES 5. THIS CONTRACTOR SHALL GUARANTEE ALL EQUIPMENT AND MATERIAL INSTAIJ.ED UNDER THIS CONTRACT TO BE FREE FROM DEFECTS FOR A PERIOD OF ONE YEAR FROM DATE Of FINAL ACCEPTANCE AND SHALL REPAIR OR REPLACE NTHOUT COST TO THE OWNER MY EQUIPMENT WHCH IS DEFECTIVE. OR IMPROPERLY INSTALLED. IN ADDITION, THIS CONTRACTOR SHALL ASSUME FULL RESPONSIl31UTY FOR ANY DAMAGE TO THE BUILDING AND ITS CONTENTS OR OTHER EQUIPMENT CAUSED BY DEFECTS OR IMPROPER NSTALLAT1ON OF EQUIPMENT OR MATERIALS INSTALLED UNDER THIS SECTION OF THE SPECIFICATIONS. 6. FABRICATE AND INSTALL GALVANIZED SLEET METAL DUCTWORKC FOR VELOCITIES LESS THAN 2000 FEET PER MINUTE AND STATIC PRESSURES LESS THAN 2' WATER GAUGE IN ACCORDANCE WL1H THE LATEST EDITION OF SHE 'LOW VELOCITY DUCT CONSTRUCTION STANDARDS' POLISHED BY THE SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION. INC. (SMACNA). ALL ELBOWS AND BRANCHES FROM MAIN N ALL SUPPLY AND RETURN DUCTS SHALL BE PROVIDED WA1H IURNNG VAF.S. A. ALL RECTANGULAR SUPPLY AND RETURN AIR DUCTWORK SHAH BE INSULATED SETH 1/2' COATED FIBERGLASS DUCT UNER - 2 PCF DENSITY INSULATION. DUCT SIZES SHOWN ON DRAWINGS FOR THIS DUCTWORK ARE SHEET METAL SIZE AND INCLUDE INSULATION. B. MAKE -UP AIR AND ROUND SUPPLY AIR DUCTWORK SHALL BE INSULATED MATH 1 -1/2" MINERAL FILLER BLANKET - 1 PCF DENSITY INSULATION. DUCT SIZES SHOWN ON DRAWINGS FOR THIS DUCTWORK ARE SHEET METAL SIZE. C. WELDED GREASE EXHAUST DUCTS FROM TYPE 1 HOODS SHALL BE INSULATED SETH 2 LAYERS OF 1 -1/2' awl FIR MASTER FIRE WRAP. DUCT SIZES SHOWN ON DRAWINGS ARE SHEET METAL SIZE. D. INSULATED FUMBLE DUCT SHALL BE SHE RUAFLEX TYPE MK -E 7. TEST AND ADJUST ALL AIR HANDING EQUIPMENT TO PROVIDE THE REQUIRED AR VOLUME AGAINST THE SYSTEM STATIC PRESSURE. TEST AND SET ALL DAMPERS AND SUPPLY, RETURN AND EXHAUST DEVICES TO CFL SHOWN ON THE DRAWINGS. PROVIDE ALL REQUIRED SHEAVE AND BELT CHANGES REQUIRED TO OBTAIN CM QUANTITIES SHIOW1 ON THE DRAWINGS TESTING AND BALANCING SHALL BE W ACCORDANCE WITH PROCEDURES OUAJNED IN TESTING AND BALANCING MANUAL AS PUBUSHED BY SMACNA. 8. FURNISH AND INSTALL ALL MECHANICAL EQUIPMENT AND AIR DEVICES AS SCHEDULED ON THE ORAVNGS. PROPOSALS SHALL BE BASED ON THIS EQUIPMENT AND NO SUBSTITUTIONS WILL BE ACCEPTED. 9. REFRIGERANT IDES SHALL BE HARD DRAWN COPPER TUBE; TYPE 1 -ACR". WITH WROUGHT COPPER RUNGS. ALL JOINTS SHALL BE BRAZED VAIN SILFOS OR EQUAL. FURNISH AND INSTALL A UQUID UNE SIGHT GLASS AND DRIER - STRAINER AS MANUFACTURED BY SPORLAN OR EQUAL INSULATE CANT SUCTION LINES AND CONDENSATE LINES WITH r FOAM PLASTIC ARMAFLEX OR EQUAL ALL REFRIGERANT INSULATION INSTALLED ON OUTSIDE PIPING SHALL BE COATED WITH 2 COATS OF UV RATED WATERPROOFING COMPOUND. NO CONCEALED JOINTS WILL BE ACCEPTABLE. 10. NATURAL GAS PWNG SHALL BE SCHEDULE 40 BLACK STEEL WITH MALLEABLE RON SCREENED FITTNGS FOR PIPE SIZES SMALLER THAN 3' AND STANDARD VA3G HT WELD FITTINGS FOR PIPE SIZES 3" AND LARGER. INSTALL GAS COCK DIRT LEG, UNION AND POUNDS - RICHES REGULATOR (F REQUIRED) WHIN 6' -0' OF EACH EQUJIPIENT CONNECTION. ALL GAS PIPING LOCATED OUTDOORS SHALL BE PAINTED WITH RUST INHIBITOR PANT. SEISMIC RESTRAINTS SHALL BE REQUIRED IN ACCORDANCE VAIN THE 1996 BOCA NATIONAL CODE MATH THE NOTED EXCEPTIONS. GAS LINE SHALL BE TESTED AT TWICE THE OPERATING PRESSURE AND MUST HOW WIHOUT LOSS OF PRESSURE FOR 24 HOURS 11. CONDENSATE PIPING SHALL BE TYPE IC HARD DRAWING COPPER COPPER ANTS SHALL BE MADE WAIN 50-50 SOLDER PIPING SHALL BE PITCHED N THE DIRECTION OF FLOW W1H A PITCH OF 1' IN 10. ALL CONDENSATE PIPING SHALL BE INSU LAITD NTH 1/2' THICK CLOSED CELL ARMAFIFX IISUAITEON. 12 MECHANICAL CONTRACTOR SHALL PRO TOE TEMPERATURE CONTROL LIMNING AS PART OF THIS 1EIDRK. ALL SYSTEMS SHALL BE COMPLETE INCLUDING ALL REQUIRED EQUIPMENT, RELAYS, SNITCHES. CONTACTORS AND f .ECTRICAL WIRING EXPOSED N RETURN MR PLENUM SHALL BE PLENUM RATED CABLE 13. PACKAGED ROOFTOP UNIT WITH GAS HEATNG, SPACE THERMOSTAT SHALL ENERGIZE DE COOLING CRCUT TO SATISFY COOING DEMANDS AND SHE GAS VALVE IHROUGII ITS SAFETY CONTROLS TO SATISFY HEATING DEMANDS TIE O OWNER SHALL RUN CONTINUOUSLY AND SHE OUTSIDE MR DAMPER SHALL OPEN FOR A PRESET AMOUNT OF VENTILATION WIENN N OCCUPIED MODE SPACE THERMOSTAT SHALL BE A TYPE SILLAR TO HONEYWELL '17300 14_ EXHAUST FANS 1T -1 AND EF-2 SHALL BE INSERIOCIGFD W1H THE LHGHTMG CIRCUIT. EF -3 SHALL RUN CONTIMIOUSLY_ 15. DISABLE ECONOMISER N ORDER TO AOC RAIELY BMANCE SYSTEML • • GENERAL HVAC NOTES 1 SHE FOLLOWING NOTES APPLY TO ALL MECHANICAL DRAWINGS. ADDITIONAL MECHANICAL NOTES MAY BE INDICATED ON EACH MECHANICAL DRAYANG. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 2 REFER TO ARCHITECTURAL AND STRUCTURAL. DRAWINGS FOR GENERAL CONSTRUCTION INCLUDING LOUVERS, CONCRETE EQUIPMENT PADS, FLASHING DETAILS, ETC. 3 REFER TO ARCHITECTURAL DRAWING FOR ROOM ELEVATIONS LOCATE MECHANICAL DEVICES SUCH AS TEMPERATURE SENSORS. HUMIDISTATS, PANELS, ETC. SO THAT THEY DO NOT CONFUCT SETH GENERAL CONSTRUCTION (WAINSCOT. DOOR HARDWARE, ETC.) NOR VATH ELECTRICAL. SYSTEM (UGHT SNITCHES, SPEAKERS, OUTLET'S. ETC.). MOUNT THERMOSTATS 48' AFF UNO. 4 MECHANICAL DRAWINGS SHOW APPROXIMATE LOCATIONS FOR GRILLES AND DIFFUSERS. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF GRILLES, REGISTERS, DIFFUSERS. AND OTHER COUNG OR SURFACE MOUNTED DEVICES. INSTALL EQUIPMENT N CONFORMANCE WTH ARCHITECTURAL FEATURES IN SHE CENTER OF CEIUNG TIES. N 111E CENTER OF ROOMS. OR %INHERE INDICATED ON ARCHITECTURAL DRAAANGS. WHERE EQUIPMENT IS NOT INDICATED ON ARCHITECTURAL DRAWINGS. OBTAIN DIRECTION FROM ARCHITECT PRIOR TO INSTALLATION. 5 SEE ARCH. DRAWINGS FOR EXACT SIZE AND LOCATION OF LOUVERS. COORDINATE EXACT SIZE OF ATTACHED DUCT110RK/1tENUM AND /OR MOTORIZED DAMPERS WITH ARCH. DRAMNVGS. 6 GENERALLY DUCTWORK PLANNED TO BE TIGHT TO STRUCTURE WAIN PIPING BELOW DUCTWORK AND BETWEEN LIGHT FIXTURES. ADJUST AS NECESSARY. 7 COORDINATE LOCATIONS OF MECHANICAL EQUIPMENT AND DUCTWORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES FOR REMOVAL AND SERVICE ACCESS DUE TO EQUIPMENT MAINTENANCE. 8 ARRANGE HVAC EQUIPMENT SO THAT ACCESS CLEARANCES INDICATED BY DRAWINGS, REQUIRED BY CODES AND RECOMMENDED BY MANUFACTURER ARE PROVIDED. PROVIDE 42' CLEAR AT DISCONNECT SWITCH ON TERMINAL UNITS WITH ELECTRIC HEATING COIL 9 PROVIDE ACCESS PANELS/DOORS IN DUCTWORK AS INDICATED 111 DIVISION 15 FOR INSPECTION AND MAINTENANCE FOR ALL SMOKE/FIRE DAMPERS 10 GENERAL CONTRACTOR TO PROVIDE ACCESS TO FERE AND /OR COMBINATION FIRE/SMOKE DAMPERS THROUGH ACCESS DOORS N HARD COMICS AND WALLS. WHERE ACCESS DOORS PENETRATE FIRE RATED SYSTEMS THEY SHALL BE RATED N ACCORDANCE NTH IBC REQUIREMENTS. 11 REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL CHARACTERISTICS OF MECHANICAL EQUIPUENT (VOLTAGES. ETC). 12 DUCTWORK AND PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM ACCESS OF 6' IF RUNNING PARALLEL AND ABOVE CABLE TRAYS, AU.OW 18' TO THE SIDE OF CABLE TRAYS. 13 ELECTRICAL CHARACTERISTICS OF USED EQUIPMENT SHALL BE VERIFIED BY CONTRACTOR DURING SUBMITTAL PROCESS. ANY ELECTRICAL CHARACTERISTICS THAT DEVIATE FROM THOSE USED SHALL BE IDENTIFIED BY THE CONTRACTOR, SUBMITTED TO DE ENGINEER FOR APPROVAL AND COORDINATED WITH DIVISION 16 PRIOR TO INSTALLATION OF EQUIPMENT AS REQUIRED TO PROPERLY SERVE EQUIPMENT. 14 DRAWNGS ARE SCHEMA1)C N SOME AREAS AND MAY NOT SHOW OFFSETS M ICH MAY BE REQUIRED. PROVIDE OFFSETS AS REQUIRED AT NOT ADDITIONAL COST. 15 REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FH1NGS. VALVES, ETC. FLOOR PLANS AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND GENERAL PIPE ROUTING ONLY. 16 DUCTS AND PIPES INDICATED VATHOUT DIMENSIONS SHALL BE SIZED PER PRECEDING UPSTREAM DUCT AND PIPE SECTIONS. 17 DUCTWORK SIZES SHOWN ARE CLEAR INSIDE DIMENSION. 18 PROVIDE FABRICATED STEEL. MEMBER SUPPORTS AS REQUIRED BY MANUFACTURE R'S INSTALLATION INSTRUCTIONS, AS INDICATED ON DRAWINGS, OR N SPECIFICATIONS FOR INSTALLATION OF EQUWIENT. REQUIRED STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE w 1Ht AMEPJCAN INSTITUTE OF STEEL CONSTRUCTION (MSC) MANUAL 19 F REQUIRED FOR INSTALLATION OF PIPES, DUCTS, AND EQUIPMENT, PROVIDE ADEUONAL STRUCTURAL MEMBERS SEMEN COLUMNS, JOISTS, AND STRUCTURAL FRAME TO MEET SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. 20 00 NOT CORE DRILL OR DRILL THROUGH BEAMS. COLMAANS` AND SHEAR WALLS, UNLESS INDICATED ON STRUCTURAL DRAWNGS OR AS APPROVED BY THE STRUCTURAL ENGINEER. 21 PROAADE DUCT LNINNG FOR SHE FOLLOWNG DUC1WORIC: A. DGIAUST ouct 1DR1C FROM EACH OWAUIST GRILLE TO A PONT 10 FT UPSTREAM OF THE GRILLE (EXCEPT FOR KITCHEN AND SHOWER DGIAUST DUCT RTC). B. ALL MR TRANSFER DUCTS AND COUNG RELIEF GRILLES. C. ALL EXHAUST DUCTWORK WTHMV 15' OF A FAN (OCCEPT KITCHEN AND SHOWIER EXHAUST). D. ALL SUPPLY AND RETURN DUCTWORK WJ1IN 15' OF A FAN. E. ALL ENDED AN AND EXHAUST AR PLENUMS. DO NOT LINE OUTDOOR AIR PLENUMS F. PLENUMS UPSTREAM OF RETURN FANS. G. OTHER LOCATIONS WHERE NOTED ON ORAWNGS OR SPEC/RED 22 PROVIDE A VOLUME DAMPER FOR EACH SUPPLY BRANCH, RETURN BRANCH (DUCTED ONLY), & °M UST BRANCH VMERE THREE OR MORE OPENINGS ARE ASSOCIATED W1H SHE BRANCH, AND ELSEWHERE AS NOTED oN DRAWNGS OR N SPECIFICATIONS 23 PROVIDE OOMCAL SPIN-IN FITTINGS FOR ALL 90 DEGREE ROUND DUCT BRANCHES FROM RECTANGULAR SUPPLY DUCTWORK. DO NOT USE STRAIGHT TEE RUNGS. 24 DUCTWORK STATIC PRESSURE AND SEAL CLASS, BASED UPON SMACNA: 25 REFER TO WASHINGTON STATE NREC COMPLIANCE REQUMEMENTS ON CRAVING SCHEDULE SHEETS FOR ADDITIONAL MECHAMCAL PRO'AStONS 26 ECONOMIZERS SHALL MODULATE OUTSDE AIR FROM MMIMAUN TO 1002 PER WSEC 1413.1 27 SEAL DUCTWORK PER WSEC 1414.1 AND PER pISION 15 SPECIFICATIONS. 28 BALANCE HVAC SYSTEM PER WSEC 141&3 AND PER EVASION 15 SPECEfICATIONS 29 COMMISSON HVAC SYSTEM PER %MC 1416.4 AND PER OMSiONN 15 SPECIFICATIONS. 30 PROVIDE COMPLETION/RECORD DRAWINGS PER NSEC 1416 AND PER DIVISION 15 SPECIFICATIONS 31 DEM STATS SHALL BE INTERLOCKED TO PREVENT SIMULTANEOUS HEATING AND COOLING PER MSEC 1422, WISEC 1435. 32 INSULATE DUC1NORIC PER WSEC TABLE 14-5 AND PER DIVISION 15 SPECIFICATIONS (1MHIIC Ew R 6 GREATER). 33 RISIJLAE PEEING PER IIMC, TABLE 14-6 AND PER DIVISION 15 SPECIFICATIONS ( ECHE R IS GREATER). 34 PATCH ALL FLOOR. WAIL, CITING AND ROOF OPENINGS CREAMED/CAUSED BY THE OINOUTlON OF E SING DUCTS, PIPES, FIXTURES, ETC N ACCORDANCE N1H OMS10N 1 SPECIFICATIONS. 35 COORDINATE DEMOUIIOII NORK WA1H ARCHITECTURAL DEIOUIION AND PHASING GRATINGS 36 COORDINATE ALL IEQIAHIGIL WORK 1111TH AROITECTURAL PHASING C RMINGS 37 PATCH Ail FLOOR EVIL, CEILING AND ROOF OPENINGS CREATED/CAUSED BY THE OEMOU110N OF EXSTa1G OM% PIPES, FIXTURES, ETC N ACOCRDMICE WJH DEMON 1 OF THE SPEOFTCATIONS 38 REFER TO AR TEfRAIIMAL SCHEDULE FOR NET AND OUTLET DUCT SIZES UNLESS INDICATED ON FLOOR PEAL • ABBREVIATIONS AC AD AFC AFF AFG AHU AL BOO IWC BHP BI BOD EITU BTUH CO CFO CV CH CRD DIA DIM DIAPR DN DP DWG EX EAT EF EFF EG ELEC FH FARENNEIT FD FIRE DAMPER RR FLOOR FPM FEET PER MINUTE FSK FOIL SKRNM KRAFT LINED DUCT (SPUQSIRAND) FT FEET. FOOT G GAS GR atILLE HP HORSE POWER HR HOUR HTG HEALING HVAC HEATING, VENTILATION AND AIR CONDIIIONNG HW HOT WATER INFO NSUL JAN JANITOR MR CONDIAONNG ACCESS DOOR ABOVE FINISHED CEIUNG ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM BACK DRAFT DAMPER BELOW FINISHED CEILING BRAKE HORSE POWER BACKWARD INCJNED BOTTOM OF DUCT BRITISH THERMAL UNIT BRITSH THERMAL UNIT PER HOUR CUBIC FEET PER MINUTE CLEAN OUT CONSTANT VOLUME COLD WATER OE0.WG RADIATION DAMPER DIAMETER DIMENSION DAMPER DOWN DIFFERENTIA. PRESSURE ERASING OOSTING ENTERING ASR TEMPERATURE EXHAUST FAN EFFICIENT, EFFICIENCY EXHAUST GRILLE ELECTRICAL INSIDE DIMENSION INCH, INCHES INFORMATION INSULATE, MSULA110N KW KILOWATT KW 1 KILOWATT FLOUR LAT LF LVG MA MBH MAT MAX TECH MFG MED MIN MSC LEAVING ASR TEMPERATURE LINEAL FEET LEAVING MDED ASR THOUSAND BRITISH THERMAL UNITS PER HOUR MDED AIR TEMPERATURE MECHANICAL MANUFACTURER MEDIUM YiiI1lIY, MINUTE MISa LLANEOUS N NA NTS OSA OAT OD OPP OV PD PERT PF PH QTY RA REQD RET RG RPM SA SCHED SD SF SFD 5.1.0. SHT SP SPEC SR SS STAT TEMP 1D TEMP THIRD ISTAT TYP UL UV UMC UP V VAC w VAC VAV VEL VOL W/ W/O WB WIC WT NORTH NOT APPLICABLE NOT TO SCALE OUTSIDE NR OUTSIDE AIR TEMPERATURE OUTSIDE DIMENSION OPPOSE OUTLET VELOCITY PRESSURE DROP PERFORATED PRE FILTER PHASE QUANTITY RETURN MR REQUIRED RETURN RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SCHEDULE SMOKE DETECTOR SUPPLY FAN SMOKE/RRE DAMPER SUPPLED AND INSTALLED BY OWNER/ (OTHER) SHEET STATIC PRESSURE SPECIFICATION SUPPLY REGISTER STAINLESS STEEL THERMOSTAT TEMPERATURE TEMPERATURE DIFFERENTIAL TEMPORARY THROUGH THERMOSTAT TYPICAL UNDERWRITER'S LABORATORY UNIT VENTILATOR UNIFORM MECHANICAL CODE UNIFORM PLUMBING CODE UNIFORM BUILDING COOE VOLT voLIS AC VOLTS DC VOLUME DAMPER VACCUM VARIABLE AR VOLUME VELOCITY VOLUME WITH WITHOUT MET BULB WATER CLOSET WATER TANK WEIGHT • i SiaantaiS No changes shall be made to the scope of icrk without prier approval of Tukwila a Building Olviaion. NOTE: Revis cns w'.3 r iie a new plan subratt l and may Inckide additional plan review fees. SEPARATE PERSIST REQUIRED FOR: City of Tukviiia WILDING DIVISION • DRAWING SYMBOLS O NORTH ARROW SECTION IDENTIFICATION SHEET IDENTIFICATION GENERAL MECHANICAL NOSES NUMBER IDENTIFICATION FLAG MECHANICAL NOTES NUMBER IDEN11F1CATION SHEET INDEX I1.0 SYMBOLS, NOTES & ABBREEAATIONS M1.1 MECH. EQUIPMENT SCHEDULES 111.2 GAS PIPING ROOF DETAILS 112.0 MECHANICAL FLOOR PLAN M2.1 MECHANICAL ROOF PLAN M3.0 CAPTIVE AR HOOD DETAILS M3.1 CAPTIVE AIR HOOD DETAILS M3.2 CAPTIVE MR HOOD DETAILS oopr Pen* No. 3 Ulan rev*" approval Is abject to errors and a1at1 Applwa_ cf rarest: on documents does not aulmotda violaMi C.., appfc.z Dom: City of lirkwila BUILDING DIVISION HV Engineering, Inc. Consulting Engineers O 7100 Linden Ave. N. Suite O Seattle, Washington. 98103 wow. w. hvengineering. biz Phone: (206) 706 -9669 Paz: (206) 71)d -I890 EF-9 MECHANICAL LEGEND SYMBOL DESCRIPTION N 0 0 40r ..." 12a + + I' vsFD cRo + m e? _.___RS tipti" TERMINALS RL REUSE OF DOOMS DOSING WORK OR BACKGROUND INFORMATION (LIGHT UNE) NEW WORK (HEAVY LINE) RELOCATE D05TIriG EQUIPMENT ITEM OR DEICE NDICAIED DOSING EQUIPMENT OR DUC110311K TO BE SELECTIVELY DEMOLISHED TYPICAL EQUIPMENT DESIGNATION (EXHAUST FAN SHOWN) CARBON MONOXIDE (CO) SENSOR CO2 SENSOR OCCUPANCY (CO2) SENSOR ROOM THERMOSTAT (I) DUCT (1ST FIGURE = S1OE SHOW+, 2ND FIGURE = SIDE NOT SH01W) FLDOB[E CONIEC110N ACOUSTIC DUCT VOLUME DAMPER 45' TAKE-OFF 1g; F ANGULAR TAKE -OFF WI111 FLEXIBLE DUCT War p �� p K1R TOWARD 00*1 O AWAY USI DUCT Mk WNW DUCT URNNG UP TOWARD � I DO T IMI OR AWAY INCLINE D CHIN E IOM► ( N tr •.% M 3.% PallEW ROUND DUCT OR PHASE INDICATOR BACKORAFT DAMPER MOTORIZED DAMPER COMBINATION SMOKE/FIRE DAMPER CEILING DIFFUSER OR GRILLE RADIATION DAMPER FIRE DAM (FD) SMOKE DAMPER (SD) 90' ELBOW, R/MM OR R/b = 1.5 WARE NI1H V AI�ES OW 90' CONICAL SPIN-t1 F ILM& 0 WYE FITTING 90' OIVERGIIG RECTANGULAR EIIMIER RAORNS CR IUR SIC WilES CITING MISER, TYPE SE BALANCE TO 350 CFY FLOW ARROWS WWI ONLY F AR ROW 6 NOT 5 M ILIIRICA1. BMAINCE TO 360 CfM� IONIZATION TYPE SMOKE DETECTOR UNDER CUT DOOR 3/4' REFRIGERANT SUCTION LIME REFRIGERANT LIQUID LINE C CONDENSATE PIPING AK OOOIJIDIT. • UE: >DEI1S NID t MOS OICORPORMED ICOR AS MIN l SOMENT OF PROITSSIONAL SERMCE. IS NC PROPERTY OF IN ONNIEERING, NC: MD IS PIOT TO EE USED. 11 moil OR MI MT. FOR NIT OVER PROJECT TMCUT AE w017EN WRIORIZA11011 OF WI OEIEDIies. O IMOIT, ITV 131011031111G. INC LTR )MP' ETE FIECIEWIED CITYOF JU! FPI PERMiT VERA' SCALE em MEASURES oIE RCM ON COMM. MAIM Cr 1� 1 noT CIE NCR CR a CRAM[,. PONST SAS ACCOICRIGLIC 152 W. Main 5t. Lena, 1L 61048 P: (81 5) 369 -9 155 f: (81 5) 369 -4495 J J f 2 U X w 2 Ptou. eeo.: 06W -055 I 05/ 1 6/06 I SHEET NCR M1.O 150 ANDOVER PARK WEST TUKWILA, WA 98188 PACKAGED AIR CONDITIONING UNIT SCHEDULE APPUCATION SERVICE ' • I •', ,, v ► ., • • 1 - • 1 - TFUCK -NCR OF LAYERS 1 1 1 re • 1 1 1 K BTU.IN A D 1� H.SQ.FT.F F 1 ARE SERVED KITCHEN /SERVICE D NIN RES1ROOMS MINERAL - FIBER BLANKET (.26/1.0) N/A 1 - 1/2' (38mm) PACKAGED - PACKAGED j G. S • 1 . C A t .� COOLI MINERAL - FIBER BLANKET (.26/1.0) TOTAL NOMINAL CAPACITY -TONS 7.5 7.5 T/ 1• • . ' : E • , :T'1 • : 1 1 _ SENSIBLE CAPACITY -_ 81UH 67,536 67,536 UNER (.26/2.0) ENT AIR TEMP -DEG F DB 85 85 ONE ENT AIR TEMP -DEG F WIT 67 67 ANDPLENUM SYSTEM POWER -KW 8 8 VOA DEG -F DB 85 85 MINIMUM SEER NONE U v14 . ire •• y. 1• S 2 EER PLV 1 11.3 11.3 N/A 1 -1/2" (38mm) AIRFLOW - -CFM TOTAL 8000 8000 'IT :.1• i' - INTERIOR KITCHEN HOOD EXHAUST DUCTS RECTANGULAR/ROUND EXHAUST AIR DUCTS (EXPOSED) OTOR HORSEPOWER (EA) 1j {2) 3 1 -t 2" / (38mm) MOTOR DRIVE ECT DII C NO FAN TYPE PROPELLER PROPELLER CERAMIC FIBER (.25/6.0) _ HEATING TWO NONE ENERGY SOURCE GAS GAS 0.1 INPUT MOH 130 130 _ OUTPUT MBH 104 104 RGS -3 s. AFUE % 80% 809 480 NUMBER OF STAGES 2 2 2 -WAY EAT (DEG F) 50.7 50.7 - (DEG F) 83.9 83.9 ( LAT SUPPLY FAN 595 I AIRFLOW -CFM 2900 2900 MIN. OSA -CFM 1100 1100 ESP -IN BS [4J 0.75 0.75 MOTOR HORSEPOWER 3 3 MOTOR BLIP 1.85 1.85 MOTOR DRIVE BELT BELT FAN RPM 1120 1120 FAN TYPE FC FC 38'x16" 1745 FILTER TYPE 1 - TYPE PLEATED PLEATED RD EFFICIENCY -% 30 30 24'x24' THICKNESS- INCHES 2 2 TYPE 1 MAXIMUM VELOCITY (FPM) 360 360 2 SOUND RATING (DB) [5] 88 88 ELECTRICAL VOLTS- PHASE -HERTZ 460 3 60 460/3/60 MCA 46 46 MOCP 50 50 LRA 66 66 VY 1GHT (LBS,, W/O CURB) 1525 1525 MANU FACTURER- DESIGN BASIS LENNOX LENNOX 1 LGA090H28SIY LGA090H2BSIY [21 [31 [61 [7] [21 [31 [61 [7] REMARKS 1 AT ARI 210/240 CONDITIONS 2 PROVIDE BAROMETRIC RELIEF DAMPER/1•I000. s3 PROVIDE 100% OSA ECONOMIZER. 4 ESP = EXTERNAL STATIC PRESSURE (DOES NOT INCLUDE FAN CASE & FILTER LOSSES) 5 AT Al I 210/240 CONDITIONS [61 PROVIDE SMOKE DETECTOR SHUT- -DOWN OF RTU W/ RETURN DUCT MOUNTED SENSOR/DETECTOR. [7] INTERLOCK OA MOTORIZED DAMPER WITH GREASE HOOD CONTROLS SUCH THAT R1U IS ON & OA DAMPER IS OPEN TO THE mum AIR FLOW POSITION MENDER THE HOOD EXHAUST FAN EF-3 IS ENERGIZED DUCT INSULATION SCHEDULE APPUCATION SERVICE NECK SIZE FORM TFUCK -NCR OF LAYERS FIELD APPLIED JACKET VAPOR RETARDER REQUIRED K BTU.IN A D 1� H.SQ.FT.F F 1 INDOOR DUCT AND PLENUM OUND SUPP4 - A114 DUCTS ( (EASED ABOVE KITCHEN CEILING MINERAL - FIBER BLANKET (.26/1.0) N/A 1 - 1/2' (38mm) ONE FOIL do PAPER YE S INDOOR DUCT AND PLENUM RECTANGULAR MAKE -UP AIR DUCTS (CONCEALED) MINERAL - FIBER BLANKET (.26/1.0) N/A 1 -1/2" (38mm) ONE PAP ER YES INDOOR DUCT AND PLENUM RECTANGULAR SUPPLY AIR DUCTS (CONCEALED & EXPOSED) UNER (.26/2.0) N/A 1/2 " (12mm) ONE NONE YES ANDPLENUM RECTANGULAR RETURN AIR DUCTS (CONCEALED & EXPOSED) UNER ( 0 ) N/A 12mm ) ONE NONE YES INDOOR DUCT AND PLENUM RECTANGULAR & ROUND GENERAL ADD) R DUCTS MINERAL- FIBER (.26/1.0) N/A 1 -1/2" (38mm) ONE FOIL do PAPER YES INTERIOR KITCHEN HOOD EXHAUST DUCTS RECTANGULAR/ROUND EXHAUST AIR DUCTS (EXPOSED) GAMIC FIBER (,25/6.0 ) � 1 -t 2" / (38mm) T NONE NO INTERIOR KITCHEN H000 EXHAUST DUCTS RECTANGULAR/ROUND EXHAUST-AIR DUCTS (CONCEALED) CERAMIC FIBER (.25/6.0) _ 1-1/2- (38mm) TWO NONE NO GRILLE REGISTER AND DIFFUSER SCHEDULE • TICS ! ! ss LNDAB MARK MODEL NO. NECK SIZE FACE SIZE MAX P.D. BORDER PATTERN FINISH NOTES SA 300 RL * 12'x8' 14 "x10' 425 0.1 TYPE 1 2 -WAY #26 - 58 TDC A3 * 6'x6760 24 "x24" 100 0.1 TYPE 3 3-WAY #26 2 8 8 bi INS s 80 24'x24" RRR r r r O O O TYPE 3 3-WAY _ amt 2 TMS * 100 24'x24' TYPE 3 3-WAY 2 DAS s 100 24 "x24' TYPE 3 4-WAY 2 SF RGS -3 *' 17"x3' 20'x4' 240 0.1 SURFACE 2 -WAY - 3 SG RGS-3 .* 21'x3" 24'x4' 300 0.1 SURFACE 2 -WAY - 3 SH RGS -3 s. 33 36'x4' 480 0.1 SURFACE 2 -WAY - 3 - VOLT'S -PHASE -HERTZ 208/3/60 WEIGHT - IBS 595 FUELT TYPE GAS RB V. RL s 4 x12 44 x14 1 0.08 ' 1 - #2. 1 RC 355 RL s 36'x14" 38'x16" 1745 0.08 TYPE 1 - #26 1 RD 355 RL * 22"x22' 24'x24' 2100 0.08 TYPE 1 - #26 2 NOTES: 1. PROVIDE KITH OPPOSED BLADE BALANCING DAMPER. 2. FRAME TO FIT LAY -IN CEILING NO SCREW HOLES. 3. PROVIDE RATH VOLUME DAMPER. MAKE UP AIR UNIT SCHEDULE EQUIPMENT EXHAUST CFM MAKE -UP AIR CFM EQUIPMENT NUMBER MUA - -1 - KEF-2 750 - AREA SERVED KITCHEN - MAU-1 - 2220 TYPE - DIRECT FIRED 1100 R1U -2 - 1100 SERNCE CONDITIONS 75 - _ EF-2 AIRFLOW CFM 2280 EF-3 100 TSP N WG TOTALS 4225 4420 OCT SP N BC [1] 0.5 POSITIVE % 5% SPEED-RPU 1121 BRAKE HORSE GIVER -MAX _ - INPUT MOTOR NIP 1 CAPACITY !HUH 275,000 ALIITUOE -FT SEA tall FAN SOUND POSER INLET SODS MBA FILTER 2' 30% ' ELECTRIC& MAX FULL LOAD AW S-FLA MCA - VOLT'S -PHASE -HERTZ 208/3/60 WEIGHT - IBS 595 FUELT TYPE GAS MANUFACTURER-DESIGN BASIS CAPTIIIEAMRE A1-0.250 -C1O `REMANRKS [11 ESP 15 EXTERNAL TO (MT MD DOES NOT INCLUDE ANY INTERNAL LOSSES (.E.. FILTERS. HX. COILS, DAMPERS, H1OOQ ET4 [2) PROVIDE 4:1 MODULATING BURNER CONTROL_ [3] PROVIDE 316 SS HEAT EXCHANGER _AIR BALANCE SUMMARY EQUIPMENT EXHAUST CFM MAKE -UP AIR CFM KEF-1 2775 - KEF-2 750 - KEF- 3 450 - MAU-1 - 2220 RTU -1 - 1100 R1U -2 - 1100 EF 1 75 - _ EF-2 75 - EF-3 100 - TOTALS 4225 4420 SPACE AIR BALANCE NEGATIVE X POSITIVE % 5% AIR BALANCE SUMMARY - KITCHEN EQUIPMENT EXHAUST CFM MAKE -UP AIR CFM KEF-1 2775 - KEF-2 759 - KEF-3 450 - MAU -1 - 2220 EF -3 100 - RTU -1 - 1100 SPACE AIR BALANCE NEGATIVE % POSITIVE % 86.4% _TOTALS 4075 3320 SPACE AIR BALANCE NEGATIVE % 23% POSITIVE % AIR BALANCE SUMMARY - DINING EQUIPMENT EXHAUST CFM MAKE -UP AIR CFM WATER VAPOR PERM PERM -IN. THICKNESS NUM R OF LAYERS R7U -2 - 1100 EF -1 75 - EF -2 75 - YES RICE COOIC R 35 TOTALS 150 1100 SPACE AIR BALANCE NEGATIVE % POSITIVE % 86.4% REFRIGERANT SUCTION AND HOT •CHAS PIPING (-40p TO 220'. >) APPLICATION SERVICE K B1U.INAT 75 y . D . l 3 H.SQ.FT.F / r �" WATER VAPOR PERM PERM -IN. THICKNESS NUM R OF LAYERS FIELD APPLIED JACKET VAPOR RETARDER REQUIRED INDOOR & OUTDOOR (EXPOSED /CONCEALED) CONDENSING UNIT TO OX COIL CELL(.26 /2.0) .10 " ( 19mm ) ONE NONE YES GAS SCHEDULE NARK COI R1U1 130 RIU2 130 IRM1 215 WJR H1R 199 FRYER 110 RANGE 215 (1NiE 106 RICE COOIC R 35 TOTAL LOAD 1202 GAS NATURAL INLET PRESSURE P1 -14. H N W C 6 . W.C. P DROP DELTA H) 0.5 IN. W.C. DOINS1REAM PRESSURE (P2 -14.7) 5.5 N. W.C. SPECIFIC GRAVITY 0.60 • 2,4:i a. 5/ 0 • • .1 1 ''3* 1 ►5 y:� ; I Ka.:r �V� �.� i;� >♦ ta l ►5 �t �i>♦ s'1,1., �I �:?T.F���Ti�� 1�•9i :1� �Fi711�[eT•�i li .� ► • mi i ce+ i Dl .' ',;. - �1i • a' /'•lr 1 �- 11►.� E.' X SIT ► 1 �: M�. { wr •;,1". Y FAN MOTOR WATTS a .• NOTES 1 ACIES BD BACKDRAFT DAMPER, DS- DISCONNECT SWITCH, RC- FACTORY FABRICATED ROOF CURB. NO BACK DRAFT DAMPER OK EF -3. NOTES: (9 ACCEPTABLE ALTERNATE MANUFACTURERS INCLUDE CAPTIVE-AIR, HECK, AND BR1EDERT. 1 1 1, 2 1. 2 .•;4 s' , ■ 1 •i 208 kat= =Y 7j Mil MI = ' 7 Y 1 j r 1`T 9 1 ■T1`' 55 1 ore I •'1'111•. 50 W 100 0.5 60 W EXHAUST AND VENTILATION FAN SCHEDULE DAMPER, ISOLATOR Kt1 AND WHITE PLASTIC GRILLE. 5/11/2006 • LOW PRESSURE NATURAL GAS PIPE SIZING CALCULATIONS GAS PIPE SIZING FOR THIS PROJECT IS BASED ON 2003 INTERNATIONAL IUD_ GAS CODE, SECTION 402.4. UfiJZNG EQUATION 4-1 AS ALLOWED THIS TABLE APPLES ONLY TO LOW PRESSURE GAS LESS THAN 1.5 PS1G N SCHEDULE 40 METALLIC PIPE OF PIPE SIZES SHOW. NOMINAL D INCHES ACTUAL ID EQUIVALENT LENGTH (FT) 10 20 MOPE SIZE MAXIMUM CAPACITY N CUBIC FEET PER HOUR 173 362 119 ' 249 30 40 82 171 50 72 152 75 100 125 150 58 122 229 50 104 196 _ 44 - 92 1 174 40 84 158 200 34 72 250 300 350 30 28 25 64 58 53 400 L 24 49 450 22 46 682 1.401 469 963 377 774 322 662 500 550 600 21 44 20 41 19 40 471 403 358 324 135 277 120 108 100 246 223 205 93 87 191 179 169 160 153 _ Z100 4.046 6,450 11.407 23,276 1,443 2.781 4,434 7,841 16.001 _ 1.159 2.2M 3.561 6,298 12,851 992 1,912 3,048 - 5,391 11,000 880 1,695 2.702 4,778 9,750 706 1,361 605 1 536 I 1 ,033 486 416 368 334 307 82 75 253 241 229 _ 2,170 3,837 ' 7,830 .165 ' 1,857 3,285 6,702 1.646 2,911 5,941 936 1,492 Z638 5,383 801 1,277 2258 4.608 710 1.132 2,001 4,084 643 1.025 1,813 3,700 592 943 1.668 ' 3,405 551 878 1.552 3,167 517 824 1.456 2,972 488 778 1.376 2.807 463 739 1.307 2.666 442 _ 705 _ 1.247 " 2,544 _ 42,126 68 28,959 46.906 23,258 37,672 19.908 32.245 17.645 28,581 14.172 22.954 12,130 19.648 10,752 - 17,415 9,742 15.780 8.339 13.507 7,391 ' 11,972 6.697 10.848 6.162 9.980 5.732 9.285 5.379 8,712 56081 , 8,230 4,86 ` 7,816 4.604 _ 7.457 0= INSIDE DIAMETER OF PIPE (RICHES) Q= INPUT RATE PH, 60 DEG. F. 30-NCH MERCURY COLUMN) P1 = UPSTREAM PRESSURE N PSIA P2 = IX ISTREAM PARE PSIA L = EQUIVALENT LENGTH OF PIPE N FEET DELTA H = PRESSIME DROP N RICHES W.C. THIS TABLE COPYWRIT1EI BY HV ENGINEERING • THIS IS PRESSURE DELIVERED TO THE BUILDING GAS PIPING SYSTEM THIS IS MINIMUM PRESSURE DELIVERED AT MOST REMOTE APPLIANCE 1 PSIG = 27.7 N. W.C. CR = FOR NATURAL GAS Y FOR NATURAL GAS 016094 0.9992 (EQUATION 4 -1 IN 2003 IFGC)I D= (00.381) /((19.17(0ELTA H/{CR'L)T0.206) NV Engineering, Inc. '-- Consulting Engineers • 7100 Linden Ave. N. Suite 1 Seattle. Washington. 98103 ww -. b•engineering_ biz GO Mown (2d6) '006 -9669 Par_ (2019106-18X0 REVIEINED FOR CODE COMPLIANCE A nnQOVIO dUt 2 7 2406 pity Of fiul� �!o . BUSING DIVISION Mop -133 RECEIVED CITY OFBIKW4) ,AN. 13"W PERMIT C&NTEI 1 152 W. Main 5t. Lena, IL 61048 P: (815) 369 -9155 F: (8 15) 369 - 4495 r rRoi. NO.: 06W -055 05! 1 6106 I SHEET NUMBER M1.1 STEEL PIPE, NOMINAL SIZE OF PIPE (IN.) SPACING OF SUPPORTS (FT-) /2 — 14 6 OR 1 8 114 OR LARGER (HORIZONTAL) 10 t 1 GAS COCK G 1 CAP DIRT LEG 6" MIN ArporieW FROM GAS METER SIZE PER PLANS T PRESSURE TAPS MIN. 10 PIPE DIAMETERS --1 LBS. TO INCHES GAS PRESSURE REGULATOR. SEE PLAN FOR CAPACITY REQUIRED. VENT AS REQUIRED. GAS PIPING CONNECTION DETAIL NO SCALE REMOVEABLE CAP NOTES:_ 1. LOCATE TRAPS SO AS TO BE ACCESSIBLE FOR aEANING. 2. HEIGHT SHALL BE EQUAL TO FAN FLOW STATIC PRESSURE, PLUS 1. ungfRanfillrWEARLVIsROOrDRA111. REMOVABLE CAP 4. VERIFY MFR. REQUIREMINT FOR P-TRAP, UNIT MAY CONTAIN INTERNAL TRAP. PIPE FULL SIZE OF AIR UNIT DRAIN CONNECTION (0 ROOF JACK DETAIL 111.2 NO SCALE NOW VALVES & FITTINGS TO BE LOCATED YAWN 6 OF EQUIPMENT CONNECTION. TO EQUIPMENT CONNECTION SIZE PER MANUFACTURERS DATA RIU CASING ROOF PAD BY MECHANICAL CONTRACTOR ROOF Ai RTU CONDENSATE DRAIN TRAP NO SCALE UNION 1 ROOF CURB 1 LJ CAP ROOF JOIST r FROM GAS METER 10" - 12" SIZED PER PLANS 1• NEOPRENE/CORK ISOLATION PADS (4) ROOFING TO 9E LAPPED UP SUPPORT UNDER CAP SHUT OFF' VALVE DIRT LEG 6" MIN. 0 . GAS PIPING CONNECTION DETAIL M12 NO SCALE 20 GUAGE SHEET METAL CAP ATTACHED WITH SHEET METAL. SCREWS OVERLAP ROOFING UP & INTO BOX 2. MIN. PITCH CANT ROOF exar TREATED TIMBER ACROSS UNIT SUPPORTS 1. ; • lairri s. / III_ Pie ;11: I .1 4.1104: 4111■A IV; 11 !!! A ROOF INSULA1KN VERIFIY THICKNESS (WHERE APPUCABLE) UNION —1 1 G TO EQUIPMENT CONNECTION. SIZE PER MANUFACTURER'S DATA NO SCALE • 1 ROL VALVES & FITTINGS TO BE LOCATED VATHIN 6'-0" OF EQUIPMENT CONN. 2X4 BLOCKING CONDENSING UNIT :N \._... - 2-HOLE ANGLE ' BRACKET SECURED . - TO TIMBER AND • - EQUIP- SUPPORT . YAM IAG SCREW I S. 3X3"X1/4 STEEL ANGLE NEEDED BETWEEN JOISTS BY HVAC CONTRACTOR \ SILCONE CAULK BEFORE ROOFING IS APPUED. ALL AROUND RPM) - ••••-:/ - .1.s.....-e. -\ .,...• - - ------ ----- -------- --..• 1--_;.. .-..... . . iii ! i 11:'i MULTIPLE PIPES THRU ROOF DETAIL 3 STEEL ANGLE %ELM - SEMEN ANGLES BELOW SUPPORT r—oir 1 1 NN i •; ROOF DECK (CORE DRILL) ( 3._ GAS PIPING DETAIL M1.2 NO SCALE \ 8' OVERHANG 18 GAUGE FLASHING GALV. SHEETMETA! CAP OVER ROOFING TACKED TO MOD NAILER 'MICRO NEIL" TYPE MM475 EQUIPMENT SUPPORT FURNISHED AM INSTALLED BY HVAC CONTRACTOR. (TYP OF 2) OR 'PATE" EQUAL ROOF INSULATION MOTE APPUCABLE) ROOFING 0 CONDENSING MIT SUPPORT DETAIL M1.2 NO SCALE PIPE OR CONDUIT ROOF STRUCTURE ROOF JOIST COORDINATE WORK REQUIREMENTS W/ STRUCTURAL ENGINEER. M.C. SHALL PROVIDE FLEXIBLE CONNECTION NTH QUICK DISCONNECT AT EACH EQUIPMENT CONNECTION. NEOPRENE BOOT ROOF MEMBRANE ROOF INSULATION — (WHERE APPUCABLE) UNIT GASKET UMT DUCT SUPPORT INSTALL SUPPORTS ACCORDING TO NATIONAL FUEL GAS CODE 1999 EDITION U-CLAMP ONE SIZE - N N LARGER THAN PIPE SIZE GALV. LAG BOLTS - N or, SINGLE PIPE THRU ROOFNOETAIL NO SCALE FLEX CONNECTION BY M.C. DUCT (BY 1LC.) 4' SOUND BAIT INSULATION "U.S.G.' UPE 1HERMAFIBER OR EQUAL BY MECH. CONTR. UNDER COMPRESSOR DAD OF UMT NM CONTRACTOR SHALL SHIM aNB DEAD LEVEL AS REQUIRED. 1 H V Engineering, Inc. Consulting Engineers 420 7100 linden Ave. N. Suite 1 430 Seattle, Washington, 98103 www. hvengineering. biz 4211 Pholw (206) 706-9660 ribiz (206) I6-Isse V' ROOF PAD BY tiC. PIPE SUPPORT DETAIL 140 SCALE ROOF CURB DETAIL NO SCALE PIPE CLAMP OTHERS GAS PIPE PIPE SET ON WOOD BLOCK SHALL MOW FREELY UNDER CLAMP 12" LONG 4X4 CEDAR OR TREATED WOOD et.ock SET IN MASTIC ON PAD GALV. STEEL OR ALUMINUM BASE BUILT UP ROOF METAL DECK (VMERE APPUCABLE) ROOF CONTRACTOR SHALL SHIM CURB DEAD LEVEL AS REQUIRED. HOLD DOWN (AS REQ WOOD NARDI RIGID INSULATION APPUED BY mEat CONTR. ROOFING MATERIAL (8Y SEE ARCHITECTURAL AM STRUCTURAL PLANS FOR FRAMING SUPPORT TH6 0001AIDST.. AND RE WS AMID 0E9GRS INOORPCRAIED HEM. AS AR INSTRUVERT OF PROFESSIONAL %MX. 6 THE PROPERTY OF NV EXIONEIERDSG, NEC. APO IS NOT TO DE USED. If MOUE OR Of PPM. FOR ART OSIER PROJECT MOW aE laniza OUlliOSIZATIOR OF NV ENONEERING. CCPIROTTL ITV OTTROZERING. OTC. •••■■• OODECOMPLIAN REVIEWED fOR PranoOV JUL 277.006 Ot Tukviiia . BUILDING °MON CANT BY MINING CCAlit VI tiEC8lEt., CITY OF AA. 13 PMii Ce.tiiEh MEE OF DOCUMENIS VEIIFY SCALE eM ITEA91613 CRIE NOT ON Mena CRANING 0 ' F NOT OW iioi Of DOS CRA1RGG 00■RAST SCMIS ACCODERIGLY. 152 W. Ivtasn 5t. Lena, IL G 1048 I 5) 369-9 I 55 f: (8 1 5) 369-4495 'MIRES 8/1/2 1 • klak MEXICAN GRILL 150 ANDOVER PARK WEST TUKWILA, WA 98188 REVISIONS _ DESCRIPTION Permit Re— $ul?mittoI ..... GAS PIPING ROOF DETAILS a, =1J ;V 0E a41. Iaasl I PROI NO.: I OGW-055 I DATE: 05/ i G/OG SHEET NUMBER M 1 .2 t 1 GAS COCK G 1 CAP DIRT LEG 6" MIN ArporieW FROM GAS METER SIZE PER PLANS T PRESSURE TAPS MIN. 10 PIPE DIAMETERS --1 LBS. TO INCHES GAS PRESSURE REGULATOR. SEE PLAN FOR CAPACITY REQUIRED. VENT AS REQUIRED. GAS PIPING CONNECTION DETAIL NO SCALE REMOVEABLE CAP NOTES:_ 1. LOCATE TRAPS SO AS TO BE ACCESSIBLE FOR aEANING. 2. HEIGHT SHALL BE EQUAL TO FAN FLOW STATIC PRESSURE, PLUS 1. ungfRanfillrWEARLVIsROOrDRA111. REMOVABLE CAP 4. VERIFY MFR. REQUIREMINT FOR P-TRAP, UNIT MAY CONTAIN INTERNAL TRAP. PIPE FULL SIZE OF AIR UNIT DRAIN CONNECTION (0 ROOF JACK DETAIL 111.2 NO SCALE NOW VALVES & FITTINGS TO BE LOCATED YAWN 6 OF EQUIPMENT CONNECTION. TO EQUIPMENT CONNECTION SIZE PER MANUFACTURERS DATA RIU CASING ROOF PAD BY MECHANICAL CONTRACTOR ROOF Ai RTU CONDENSATE DRAIN TRAP NO SCALE UNION 1 ROOF CURB 1 LJ CAP ROOF JOIST r FROM GAS METER 10" - 12" SIZED PER PLANS 1• NEOPRENE/CORK ISOLATION PADS (4) ROOFING TO 9E LAPPED UP SUPPORT UNDER CAP SHUT OFF' VALVE DIRT LEG 6" MIN. 0 . GAS PIPING CONNECTION DETAIL M12 NO SCALE 20 GUAGE SHEET METAL CAP ATTACHED WITH SHEET METAL. SCREWS OVERLAP ROOFING UP & INTO BOX 2. MIN. PITCH CANT ROOF exar TREATED TIMBER ACROSS UNIT SUPPORTS 1. ; • lairri s. / III_ Pie ;11: I .1 4.1104: 4111■A IV; 11 !!! A ROOF INSULA1KN VERIFIY THICKNESS (WHERE APPUCABLE) UNION —1 1 G TO EQUIPMENT CONNECTION. SIZE PER MANUFACTURER'S DATA NO SCALE • 1 ROL VALVES & FITTINGS TO BE LOCATED VATHIN 6'-0" OF EQUIPMENT CONN. 2X4 BLOCKING CONDENSING UNIT :N \._... - 2-HOLE ANGLE ' BRACKET SECURED . - TO TIMBER AND • - EQUIP- SUPPORT . YAM IAG SCREW I S. 3X3"X1/4 STEEL ANGLE NEEDED BETWEEN JOISTS BY HVAC CONTRACTOR \ SILCONE CAULK BEFORE ROOFING IS APPUED. ALL AROUND RPM) - ••••-:/ - .1.s.....-e. -\ .,...• - - ------ ----- -------- --..• 1--_;.. .-..... . . iii ! i 11:'i MULTIPLE PIPES THRU ROOF DETAIL 3 STEEL ANGLE %ELM - SEMEN ANGLES BELOW SUPPORT r—oir 1 1 NN i •; ROOF DECK (CORE DRILL) ( 3._ GAS PIPING DETAIL M1.2 NO SCALE \ 8' OVERHANG 18 GAUGE FLASHING GALV. SHEETMETA! CAP OVER ROOFING TACKED TO MOD NAILER 'MICRO NEIL" TYPE MM475 EQUIPMENT SUPPORT FURNISHED AM INSTALLED BY HVAC CONTRACTOR. (TYP OF 2) OR 'PATE" EQUAL ROOF INSULATION MOTE APPUCABLE) ROOFING 0 CONDENSING MIT SUPPORT DETAIL M1.2 NO SCALE PIPE OR CONDUIT ROOF STRUCTURE ROOF JOIST COORDINATE WORK REQUIREMENTS W/ STRUCTURAL ENGINEER. M.C. SHALL PROVIDE FLEXIBLE CONNECTION NTH QUICK DISCONNECT AT EACH EQUIPMENT CONNECTION. NEOPRENE BOOT ROOF MEMBRANE ROOF INSULATION — (WHERE APPUCABLE) UNIT GASKET UMT DUCT SUPPORT INSTALL SUPPORTS ACCORDING TO NATIONAL FUEL GAS CODE 1999 EDITION U-CLAMP ONE SIZE - N N LARGER THAN PIPE SIZE GALV. LAG BOLTS - N or, SINGLE PIPE THRU ROOFNOETAIL NO SCALE FLEX CONNECTION BY M.C. DUCT (BY 1LC.) 4' SOUND BAIT INSULATION "U.S.G.' UPE 1HERMAFIBER OR EQUAL BY MECH. CONTR. UNDER COMPRESSOR DAD OF UMT NM CONTRACTOR SHALL SHIM aNB DEAD LEVEL AS REQUIRED. 1 H V Engineering, Inc. Consulting Engineers 420 7100 linden Ave. N. Suite 1 430 Seattle, Washington, 98103 www. hvengineering. biz 4211 Pholw (206) 706-9660 ribiz (206) I6-Isse V' ROOF PAD BY tiC. PIPE SUPPORT DETAIL 140 SCALE ROOF CURB DETAIL NO SCALE PIPE CLAMP OTHERS GAS PIPE PIPE SET ON WOOD BLOCK SHALL MOW FREELY UNDER CLAMP 12" LONG 4X4 CEDAR OR TREATED WOOD et.ock SET IN MASTIC ON PAD GALV. STEEL OR ALUMINUM BASE BUILT UP ROOF METAL DECK (VMERE APPUCABLE) ROOF CONTRACTOR SHALL SHIM CURB DEAD LEVEL AS REQUIRED. HOLD DOWN (AS REQ WOOD NARDI RIGID INSULATION APPUED BY mEat CONTR. ROOFING MATERIAL (8Y SEE ARCHITECTURAL AM STRUCTURAL PLANS FOR FRAMING SUPPORT TH6 0001AIDST.. AND RE WS AMID 0E9GRS INOORPCRAIED HEM. AS AR INSTRUVERT OF PROFESSIONAL %MX. 6 THE PROPERTY OF NV EXIONEIERDSG, NEC. APO IS NOT TO DE USED. If MOUE OR Of PPM. FOR ART OSIER PROJECT MOW aE laniza OUlliOSIZATIOR OF NV ENONEERING. CCPIROTTL ITV OTTROZERING. OTC. •••■■• OODECOMPLIAN REVIEWED fOR PranoOV JUL 277.006 Ot Tukviiia . BUILDING °MON CANT BY MINING CCAlit VI tiEC8lEt., CITY OF AA. 13 PMii Ce.tiiEh MEE OF DOCUMENIS VEIIFY SCALE eM ITEA91613 CRIE NOT ON Mena CRANING 0 ' F NOT OW iioi Of DOS CRA1RGG 00■RAST SCMIS ACCODERIGLY. 152 W. Ivtasn 5t. Lena, IL G 1048 I 5) 369-9 I 55 f: (8 1 5) 369-4495 'MIRES 8/1/2 1 • • • • • • 00. w o ' g e c g rr IP IG I D VMS ' %PR A PA . -.r.rr ■■■■e..... -. 5 1 1 co al )i GNI 0 A en a 11 ni 11 I i 0 14 Pi v 1.1: Eli el A �N i FR Fyri C R1 N r'N co i Iv A 4 a 0 g: g i m a�D II g 1 0 0 'a 1 z • z C) 30 1" 1 r..tJ�• 1 //777 /777/ -.; _ _ 1 w1�1 1 F:�_�.�K t .• 1••7/ Ii i � ��`Qr[' .a.::«.._ !. ,..Nr.1. ,. .4, I �;;;�11_ r hIle.••■ir 1• 'II; _ • :. • : U '• i ! t ;:}! • iCh N • . I • . • ,• . . • ... . .y • S' ' . ,. l •• ,-;- t• 'I J1 .I • o i .1 • • 1• • • • y • M. f. .' • • • ItY ��� �% •y �'.�''� � >�� %i �i'!� /.' %i I'� /I� / if / / % / /. /i ��Lr /•� �l.�.I 1(.1. ,; t A • • •, ...1.1 1 •• ,•... • •. ••,;' 1'.x,':1 /.f _, t ?.rtlil:i i N1 1 P • 2,o , RR r. m co rn 0 1 0 1, z v m -1 1 : "1 Z O g ;q I PA N i irigg 1 1: > p 2 g4 g g 'me 111 0 P1)4 ‘14° "12115 " ill. $ leg/ 11 g M I ig 1014 1 gal :II 1 MER 2 p 0 /1 411 : 41 111 Iliggi !Pig 1 P ! • C2 ! ti•ittr•' I • I r —.4.- .... 0 I r •'•r rr+ •••• • � . i ! i • • _...�......,._.... Igi N ' • J. or I • :911 , • r /. r n•- y„ , ,I fif �"'!' ' ,--.,...r.1/47.1 i ^\ 1 \ NI P t 1 I i ,I ,• 1 I ! 1 •R I 1 1 og z0 • O A z 2 ,° 410 sai 11 co NI o EMx 1 I • 1 i L_ _; O z O A 8 4 A r c m dui O 0 wri m -1 in ;r1g10 OgWg51 stcAsca WW2 i 14 Pf' Z�� iv 1012 m s crt � a ggin S Pol o 1 E $> r•Mg dII Vie, Z� t: o§ 8 me 41•011=01.11111 91■111■■ I RN 3 � z PIO D 1 C ZN O 1. Ig X18° Ping A 4 ;1'0 Ma dim; 1 • g Rog 21E g2& fl Q AAO 0 C 9 C sm f11 l � N E MP - ZAmz A4.752E2 M � G O' pZS + O Ov a S1 gcl m olg r4. q RI * ' P ` gy m g S0 z 0 El Igi °" %A. AoR • 00 ■ i, .,,,,,,....„ .. ,. t. ). ... CD, \ "°'''''. '0 al ''or.1.4.4Qf- . .I.I.-- 0 ...:„...."..,... 5...,_ .: i.e....noir. . . !C: : : :i . Pt 11'. .1, i i :. . " 7::::: 4.- .;:iii.1:i:3:1.- `44,,e•It.- ! 1 .. :. °Z. I 1 .: 1 . 1 .7 1 1 :. 1 .-..-;..i.l i i • . 07". r'1 1: "2":"AN• ' 4— :: 4. / : • 772 . 6 . :t ........ : 4 4;:-----i. , . ...te; m 7....24:i --3- o ,,,� g: 2 . Z © MECHANICAL FLOOR PLAN ,��__ 6::::::::::::::::::::::::: REVISIONS DESCRIPTION DATE doho klit MEXICAN GRILL 150 ANDOVER PARK WEST TUKWILA, WA 98188 OMAN Y KW Oita VP t C MCCKCD by Na APPKOVCD Y r� 1 --_� 5D5 5D8 TGh TGh • • • • • 00. w o ' g e c g rr IP IG I D VMS ' %PR A PA . -.r.rr ■■■■e..... -. 5 1 1 co al )i GNI 0 A en a 11 ni 11 I i 0 14 Pi v 1.1: Eli el A �N i FR Fyri C R1 N r'N co i Iv A 4 a 0 g: g i m a�D II g 1 0 0 'a 1 z • z C) 30 1" 1 r..tJ�• 1 //777 /777/ -.; _ _ 1 w1�1 1 F:�_�.�K t .• 1••7/ Ii i � ��`Qr[' .a.::«.._ !. ,..Nr.1. ,. .4, I �;;;�11_ r hIle.••■ir 1• 'II; _ • :. • : U '• i ! t ;:}! • iCh N • . I • . • ,• . . • ... . .y • S' ' . ,. l •• ,-;- t• 'I J1 .I • o i .1 • • 1• • • • y • M. f. .' • • • ItY ��� �% •y �'.�''� � >�� %i �i'!� /.' %i I'� /I� / if / / % / /. /i ��Lr /•� �l.�.I 1(.1. ,; t A • • •, ...1.1 1 •• ,•... • •. ••,;' 1'.x,':1 /.f _, t ?.rtlil:i i N1 1 P • 2,o , RR r. m co rn 0 1 0 1, z v m -1 1 : "1 Z O g ;q I PA N i irigg 1 1: > p 2 g4 g g 'me 111 0 P1)4 ‘14° "12115 " ill. $ leg/ 11 g M I ig 1014 1 gal :II 1 MER 2 p 0 /1 411 : 41 111 Iliggi !Pig 1 P ! • C2 ! ti•ittr•' I • I r —.4.- .... 0 I r •'•r rr+ •••• • � . i ! i • • _...�......,._.... Igi N ' • J. or I • :911 , • r /. r n•- y„ , ,I fif �"'!' ' ,--.,...r.1/47.1 i ^\ 1 \ NI P t 1 I i ,I ,• 1 I ! 1 •R I 1 1 og z0 • O A z 2 ,° 410 sai 11 co NI o EMx 1 I • 1 i L_ _; O z O A 8 4 A r c m dui O 0 wri m -1 in ;r1g10 OgWg51 stcAsca WW2 i 14 Pf' Z�� iv 1012 m s crt � a ggin S Pol o 1 E $> r•Mg dII Vie, Z� t: o§ 8 me 41•011=01.11111 91■111■■ I RN 3 � z PIO D 1 C ZN O 1. Ig X18° Ping A 4 ;1'0 Ma dim; 1 • g Rog 21E g2& fl Q AAO 0 C 9 C sm f11 l � N E MP - ZAmz A4.752E2 M � G O' pZS + O Ov a S1 gcl m olg r4. q RI * ' P ` gy m g S0 z 0 El Igi °" %A. AoR • 00 ■ i, .,,,,,,....„ .. ,. t. ). ... CD, \ "°'''''. '0 al ''or.1.4.4Qf- . .I.I.-- 0 ...:„...."..,... 5...,_ .: i.e....noir. . . !C: : : :i . Pt 11'. .1, i i :. . " 7::::: 4.- .;:iii.1:i:3:1.- `44,,e•It.- ! 1 .. :. °Z. I 1 .: 1 . 1 .7 1 1 :. 1 .-..-;..i.l i i • . 07". r'1 1: "2":"AN• ' 4— :: 4. / : • 772 . 6 . :t ........ : 4 4;:-----i. , . ...te; m 7....24:i W a . • 506.3.111 Termination above the roof. Exhaust outlets that terminate above the roof shall have the discharge opening located not less than 40 inches (1016 mm) above the roof surface. 506.5 UL 762 USTED FAN W/ HINGED BASE. MOUNT ON EXHAUST DUCT EXTENDED 18' ABOVE ROOF SURFACE. PROVIDE SAFETY DISCONNECT SWITCH AT FAN AND FLEXIBLE CONDUIT TO ALLOW REMOVAL FOR CLEANING THIS SHALL NOT TAKE THE PLACE OF THE SERVICE DISCONNECT PROVIDED BY DIV. 16 506.31 DUCTS: 16 GA. BLACK IRON OR 18 GA. STAINLESS STEEL - CONIRACTOR OP 2 LIQUID TIGHT EXTERNAL WELDED 506.3.4 AR VELOCITY IN DUCT NOT LESS THAN 1500 FPM AND NOT MORE THAN 2500 FPM. 9n TYPE 1 UL710 HOOD. 507.6 SUPPORT AT EACH CORNER TO STRUCTURE ABOVE NTH ALL THREAD RODS. 507.9 PROVIDE CLEARANCE COMBUSTIBLES PER REQUIREMENTS OF UL USING. 507.16 PROVIDE PERFORMANCE TEST AT COMPLETION OF INSTALLATION PLAN NOTES MECHANICAL, 11 PROVIDE GAS HEAT PACKAGED ROOFTOP UNIT AS SCHEDULED AND SPECIFIED. UNIT SHALL SET DEAD LEVEL, PROVIDE ALL SHIMS AND BUILD UP MATERIALS AS REQUIRED. PROVIDE LOW PRESSURE GAS PIPING CONNECTION PER DETAIL EXTEND 1 CONDENSATE DRAIN FROM UNIT CONNECTION TO NEAREST ROOF DRAIN. EXTEND VERTICALLY DISCHARGED SUPPLY AND RETURN DUCTS FROM FULL SIZE REMOTE CONNECTIONS AT UNIT CONNECTIONS AND TRANSITION TO DUCTS SIZED AS SHOWN. O 2 GAS HEAT MAKE -UP AIR UNIT PROVIDED BY FOOD SERVICES EQUIPMENT SUPPUERAS SCHEDULED AND SPECIFIED. UNIT SHALL SET DEAD LEVEL, PROVIDE ALL SHIMS AND BUILD UP MATERIALS AS REQUIRED. PROVIDE LOW PRESSURE GAS PIPING CONNECTION PER DETAIL EXTEND VERTICALLY DISCHARGED SUPPLY DUCT FROM FULL SIZE FLEXIBLE CONNECTION AT UNIT CONNECTION AND TRANSITION TO DUCT SIZED AS SHOWN. 40 ROOF MOUNTED EXHAUST FAN PROVIDED BY FOOD SERVICES EQUIPMENT SUPPLIER AS SCHEDULED AND SPECIFIED. UNIT SNAIL SET DEAD LEVEL, PROVIDE ALL SHIMS AND BUILD UP MATERIALS AS REQUIRED. EXTEND DUCT FROM UNIT CONNECTION SIZED AS SHOWN TO DUCT IN PLENUM SPACE. O 4 COOLER COMPRESSOR PROVIDED BY FOOD SERVICES EQUIPMENT SUPPLIER. UNIT SHALL SET DEAD LEVEL ON SUPPORT CURB. EXTEND REFRIGERANT PIPING TO CORRESPONDING EVAPORATOR COIL COAT REFRIGERANT PIPING INSULATION EXPOSED TO THE ELEMENTS MATH WEATHER PROOF UV RATED REFRIGERANT COATING. SUPPORT CURB TO EXTEND A MINIMUM OF 6' BEYOND EQUIPMENT. O PROVIDE PIPE BOX ON ROOF. FLASH AND SEAL WATER TIGHT. EXTEND REFRIGERANT PIPING SIZED AS SHOWN THROUGH PIPE BOX TO UNIT CONNECTION. SEE DETAIL 6/111.2. EXTEND GAS PIPING SIZED AS SHOWN THROUGH ROOF. FLASH AND SEAL ROOF PENETRATION WATER TINT. SEE DETAIL 7/111.2. O 7 WATER HEATER FLUX= FROM BELOW. SEE SHEET 142.0 FOR CONTINUATION. SEE FUZE TERMINATION DETAIL 1/142.0. INSTALL ROOF JACK PER DETAIL 8/111.2 EMEND EXHAUST AIR DUCT FROM ROOF JACK THROUGH ROOF TO CEILING MOUNTED EXHAUST FANS AS SHOWN ON SHEET M20. • 4 1 506.3.123 TERMINATION LOCATION FOR EXHAUST FAN SHALL BE LOCATED NOT LESS THAN 10 FEET HORIZONTALLY FROM PARTS OF THE SAME OR CONTIGUOUS BUILDINGS. ADJACENT PROPERTY LIMES AND AIR INTAKE OPENINGS INTO ANY RAMC AND SMALL BE LOCATED NOT LESS THAW 10 FEET ABOVE THE ADJOINING GRADE LEVEL 506.5.5 IERI NATION LOCATION EXCEPTION: THE MINIMUM HORIZONTAL DISTANCE BE IEEE N VERTICAL DISCHARGE FANS AND PARAPET -TYPE BUILDING STRUCTURES SHALL BE 2 FEET PROVIDED THAT SUCH STRUCTURES ARE NOT HIGHER THAI THE TOP OF DIE FAN DISCHARGE OPENING. INTERFACE HOOD CONTROLS AS FOLLOWIS. MIEN HOOD 6 ENERGIZED DE HOOD EXHAUST FAN AND THE MAKE UP AR HANDIER WALL BE STARTED. SEE SHEET 113.2 FOR DETANL MIEN FIRE IS SENSED BY HOOD FIRE CONTROL CABINET THE SOLENOID GAS VALVE TO THE APPUAICES BELOW THE HOOD ILL BE CLOSED. SECTION 9CML 1/4 = i'OO O6.3.Z3 FLARE AND GASKET DUCT TO MATCH FAN BASE. 506.3.3 BRACKET DUCT TO TOP OF CURB AT FOUR POINTS. MANUFACTURER'S VENTILATED CURB 506.3.1Q PROVIDE JOHNS MANSVALE SUPERDUCT FRE TEMP VAMP IN LIEU OF GREASE DUCT ENCLOSURE PER EXCEPTION NO 1. INSTALL PER 1HE REQUIREMENTS OF THE MANUFACTURER'S LISTING INSTRUCTIONS. 506.122 DUCT -TO -HOOD JOINTS SHALL BE EXTERNAL UQUD -TIGHT NEEDED APPROXIMATELY 200' FROM THIS POINT TO GAS METER c-� I R1U-1 '-C MPG htiI I N 1 I `;3 �vl I NI N I t • • . � ..�. • • . N a , S / • • • • • • N • N. • ♦ J 1wC 1'G i'G 10' GAS REG, 2PSI TO 7' WC, 1202 MBH, 400' EQUIV. LENGTH DOWNSTREAM • • • ♦ • • • ■ GAS REG VENT, TERMINATE MATH CODE REQUIRED SEPERATION FROM AIR INTAKES. TURN DOWN AND SCREEN oci. ' ROOF PLAN in MECHANICAL SCALE 1/4 = i 0 Ht' Engineering, Inc. Consulting Engineers 7100 linden Ave. N. Suite 1 O Seattle. Washington. 98103 www bv+engineering. biz ® Mowe (206) 701 -9669 Far: 1206) 'FOR -E630 ,_:NA tAi 1E • • 1 i 111 I„ T it Li its ::f I! II, 1:'i ' If MIt1IU11 CLEARANCE TOIOUTSIDE MR • • I : REUSE OF oocUMBns wn AS PH wswnrws a wsa PROPERTY a mr orate we w riac ae M PART. � ANY o RE AUTHORIZATION 6 M OOP ass DOCUMENT. - n Ws AND oE9(,1eS NCOtiPORAIED ME1I7� . ITS Iii INSIRIIII NT OF PROFESS ION& %M ACE. IS THE PR OPORTY OF till ENGI EERiuG. NC. #J IS NOT TO SE USED, w tttIOLE CR N PART. � ANY 01FER PROJECT MINIM INTIM AUTHORIZATION OF NV DI EEANG. COMMIT. HV OIC,IIEI sG I • ✓,....-- I nK REVIEWE C� CODE COIN fir• nnvcn MN- 133 yEU CITY OF Jilt 13 PERMIT GENTi R VERFY SCALE BAR MEASURES ONE RIM ON COMM CRANING F NOT ONE NCH ON HMS MOM ;. MOST 9GI&ES ACOOROINGLY P: (81 5) 369 -9155 F: (8 I 5) 369 - 4495 8/1/2007 l J J 0 Z 0 X W 2 0 as a. PROJ. NO.: 06W -055 5/i 6/06 I SHEET NUMBER M2.1 I- 0 N-- to m o 1 • • I REVISIONS �• DESCRIPTION DATE AU Permit - •m •I -? _ CAPTIVE AIR HOOD DETAILS APMOVCD N91 ZN Aq I4J I N IlQ �aGJ R A MVII V- 01 9aS PAGE 1 11403114•11. 30/7 HEN X 1141 t)!IG PAGE 2 1E7T OA STAFF 7 WE LEFT SIDESPiAfM (0110' WWI X 4•00• LING 300® w r� .. M II' I 2' HI(iI SUPPLY COLLAR COMECTIIN 27' TYP. usrf — C V.::DCT• ere w,.M5 Z iAC ; s W am! `U. k! v:.CiIL .W. Hood U t • s e . - e s 1 -- awl. ----- � III. Ltsted trrcavldascmt E� V' ZJ HOOD II RAN VIEW - 9'3.A0•LONG 4824MR -BR A Au ammo: ram - s 1 sAac*t* t 31)Ar NM X MAP UP EQUIPMENT BY OTHERS 570000 7 30011oi•19' 327U • RISER 100w 101PORPHOOF I CANDESCDn EIGHT IOW H0001155CDON VIEW - MODEL 4824 -AVVR • 0 VRAPPER 1110111 SO ilf ono' Item 48' NMK 24• cam 0 0 RDIOVAtLE, PE RiE RATED STAINLESS STEEL PANEL 091 as AMIN/ s , = = REV. 1.00 MI ELECTRIC,/ APO PLUNIDI CT>talOCTItl1S MST DE LOCATED DFLOV THE BAD( RETURN AIR FL OM FN. t UMW SVITOI ./00 ODOBA - TUKVILLA 1440118 LOCATION TUKVILLA, VA 12411E 4/28/20% OWGI JOB CAPTIVE -AIRE HOODS ARE BUILT IN COMPLIANCE V1TH NFPA 096 AND ARE RECOGNIZED BY ONE OR MORE I F THE FOLLOVINGc NSF INTERNATIONAL ETL LISTED FILED 3054804 -001 LOIGAIION TUKCVILLA, VA DATE 4/28/2006 C 140 ..01_440118 RE! LAO MIGHT WATER DO M L r JOD, 440118 DRAWN DY SCALE 8.5' x 11' QDOBA - TUKVILLA 1440118 J179, 440118 DRAIN DY 5011E 85'x11' PAGE 3 42.0000 Hood 02 3110000 5' OOO•Now./5 050'OD BACKSPLASH 80.00' HIGH X 60.00' LONG H0000I2 PLAN VIEW - 0.00' LONG 42241/111-G .0 am mamma ant — _ _ - - LAP' • PLFA5E VERIFY LENGTH OF WAIL . RIGHT SIDESPLASH 80.00' HIGH X 42.00' LONG .x QDOBA - TUKVILLA *440118 LOCATION TUKVILLA, VA TIME 4/28/2006 ./001 440118 DWG/ JOB_440118 DRAWN DY REV_ 1.00 SCALE a5' x 11' BACKSPLASH 80.00' HIGH X 60.00' LONG PAGE 4 . T $ RFCOVV:%YD V :`5T 11.1+.007Y D OTt ial: •••7:1% Tr.• (tZ MT CA VCA D c RAE RICCVVF.‘-reli. 5061.3.10 Grease duct enclosure. A grease duct seniag a Type I hood that penetrates a ceiling. wall or floor shall be enclosed from the point of penetration to the outlet seminal_.._ ...Clearance from the dna to the interior surface of aubsunes of combustible oo suuction shah be not less than 18 inches (457 min). Clearance from the duct to the insaior surface of enclosures of noacombasslbk construction or g}psais wall board attached se noncombustible stn cares shall be not less darn 6 inches (152 min). The duet a00611rae shall setie a single grease exhaust duct sysian and shall sot contain arty-other ducts, piping, wiring or extents. 004MIST RISER FULL LENG ANGLE S IM) ALEIW&U NESH FILTER VERDI SITTER ETUt EOIAPIENT DT OTHERS - -FIELD VIMPPae Stir HMI roan , lift ona SECTION VIEW - MOM 4224 -W11 WTRI MIL MUM? Gun= /1 As anthem.__ - r_ jip MD a s a►s�� -- _ • NM L60 CAPTIVE -AIRE HOODS ARE BUILT IN COMPLIANCE WITH NFPA 196 AND ARE RECOGNIZED BY ONE OR 1110E OF THE FOLLOWING* NSF INTERNATIONAL ETL LISTED FILES 3054804 -001 JOO QDOBA - TUDCVILLA 1440118 LOCADONf TUCVILL.A. VA DAM 4/28/2006 DWG / .01_440118 I JIOD• 440118 DRAWN Dr SCAI.f as x 11' • PAGE 5 BACKSPLASH 80.00' HIGH X 36.00' LONG ILII 0 0 0 HOOD 03 PLAN NEW- .7a00° LONG 36241/H1 4 an JOD QDOBA - TUKVILLA 1440118 LOCA7ON TUKVILLA, VA DATE 4/28/2006 JKOI 440118 DWG l JOB_440118 DRAWN BY REV. 1.00 SCALE 8.5' x 11' N* LG NOT TO XSTAZi -C '. PAGE 6 lIV Engineering, Inc. Consulting Engineers 7100 linden Ave_ N.. Suite O Seattle. Washington. 96103 hvengineerina_ biz Maw (2A6) 7 -9669 Far_ (216) :110 -1010 EXHAUST RISER f FULL LENGTH NIUE (TYPICAL.) ALUMNA! MESH FILTER FUI1 PERIMETER -\ GUTTER I (RAIN EQUIPMENT BY OTHERS 1 1 01As ms...•w R OWN _ 1201L 3 IIIIIZOISK llsl - 101Ha SRN WWI TERI PDOIETERGLITTER w _ LAP" MUSE OF DOCUMENTS REVIEWED CO CE CODE JUL 2 7 2006 (qty 4f Tukwila . [�N 8UILDIN , CAPTIVE -AWE HOODS ARE BUILT IN COMPLIANCE WITH 1*PA 1% AND ARE RECOGNIZED BY ONE ER MORE OF THE FOLLOVINGe NSF INTERNATIONAL ETL LISTED FILED 3054804 -001 QDOBA - TUKVRLA 1440118 io ii ON TIKVILIA, VA DMUE 4/28/2006 DiIG/ J03_440118 Iet1/_ LAO NS °CONDI . AND DIE IDEAS NO OE9R71S NCORI'ORA*ED HEM As NI EISTP NDIT OF PROFESSIONAL SEWA t:. IS RE PROPERTY OF NV eIGNEERRIC,. INC. 1104 IS NOT TO OE USED. N MOLE OR N PAST. FOt mr ONOT PROJECT 1EI01QIT A'E URtTIEN AUNORIZA11101. OF NV EIIP ED•R,. CCPITIA (L ill O • X09/ 440118 DRAWN DY SCALP 8S' x 11' Mo- C1T mcv li(4 I i ; t a REGEWED i 3 :wfi PERMIT GENTEF1 VEIRFY SCALE SIRKA9 S OE NCH Or CRIGa1AIL ORATING F NOT O11E NOT CPI itsS ORNINC,, ADJUST SCALES ACCY lingle design group, inc. 152 W. Main 5t. Lena, IL 61048 f': (81 5) 369 - F: (8 1 5) 369 - 4495 Illinois Professional Design Firm OAU. DRA * i MO MiTTCN UMT[•AI COBITAllle InStt• ARE Tie r40rfor or IAaae vegan occur. F .T erWY MOfeeICY.9CD. MVO. RR76CD. venom Ri MY V .Y M MR►UUT IMucN AUTrOWATION MOM TK MO1TECT. EXPIRES 8/1 /2 J J 0 z Q U X W z PROJ. No.: 06W -055 DATE 05/ 16/06 SHEET MAR M3.0 l FON iL FAN UM! MODEL I , EXHAUST FIN SUPPLY FIN IINEL. TAG CFN SP. RPM HR 0 VELT fl.A BLOWER MOUSING TAG CFN SP RCN HIP. 0 VILE FLA 1 01CA16FA M MU A RIGHT QUARTER DID PANEL 2r Top Width, V Bottom Width, 2775 ' LONG 1026 1.000 3 200 33 RIGHT SIDESPLASH 80.00' High X 4290' Long 304 SS 3 / LOB 208 33 FIELD VRAPPER 1fl00' 11gh Front, Left, Rlght, 2 AI- D250-1310 BACKSPLASH Mr High X 36.00' Lang 304 SS FIELD VRAPPER 1800' High Front. Left, RHgfnt, G10 A1-11250 2220 0.500' 1121 1000 3 203 33 3 DIJ54FA DUlSNfA 750 / 8600r 1058 0500 1 115 63 4 1911 11U251FA 450 11500' 1095 0250 1 115 3.4 NO OPTION MOIA[E I MATn4 SWITCHES I LEFT END STANDOFF 3' Vide FANS LOCATION GUMMY TYPE BACKSPLASH 3800' Nth X 114.00' Lana 430 SS HP. MOLT M 1 LEFT SIDEMAN' 8000' 08h X 40.00' Long 430 SS 2 : 7_'.• Valt Noma! rVar Nount Right Side Hood • I 1 .t 1 Fin FIELD WRAPPER 1500' HO Front, RJpht, Exhaust 1n Rte, is out M Fire Odtaust 3 MOOD RIGHT QUARTER DID PANEL 2r Top Width, V Bottom Width, 21.' Nigh 430 SS 2 BACKSPLASH 8090' Nigh X 6000' Long 304 SS RIGHT SIDESPLASH 80.00' High X 4290' Long 304 SS 3 / LOB 208 33 FIELD VRAPPER 1fl00' 11gh Front, Left, Rlght, 3 BACKSPLASH Mr High X 36.00' Lang 304 SS FIELD VRAPPER 1800' High Front. Left, RHgfnt, NO TAG MOIA[E I MATn4 SWITCHES ROOFTOP STARTERS 0 1 FANS LOCATION GUMMY TYPE • HP. MOLT M 1 • 3 2 : 7_'.• Valt Noma! rVar Nount Right Side Hood • I 1 .t 1 Fin 0 4 Exhaust 1n Rte, is out M Fire Odtaust 3 MOOD BM 33 SUp•ty 3 / LOB 208 33 MI I ITDI SUE c 1 0 1 Ctsb 263IG'V x 2f.50111. x 20I01PH Vented Hinged 2 1 2 Orb 2100ry x 71.00VL x MOWN hoisted 3 • 3 Curb 195WV x 145001. x 2000011 Vented iiiped 4 0 4 Curb I'LS00'V x 195001 x 2200091 Vented Hasped FAN NOBEL HT v B c i R 1.0 WIGHT- LB 111251FA 251/4 2512 2 21 161? 121/8 171? 50 FAO NOEL HT V B C BODES) F LDIGTH R R i Vt.[ LI 0U150HFA 27 1/4 28 7/8 2 21 21 1/2 13 1/4 17 1/2 55 A MEN (Qty. - Be5crJ TH C NELTE1t TS TOTAL SUPPLY CFI BODES) WIDTH LDIGTH ANGLE CFI SP I 1 6' 114' YES 1806 5' 36' Straight 902 0.067 36' Straight _ 902 0.069' FIIH H9 MEN (Qty. - Be5crJ 1 1 - Grease Boot FAN owl NT V B C F R RO NEIGH LB NGAI6F 33 3/4 39 3/8 2 28 23 1/2 16 1/2 24 190 !iv BTU's raIR RISE GAS TYPE I 2 196603 90 deg F Natural FAN MODEL D E DINOHrA 19112 20 INT 1100. B E MSc* 19 112 22 FAN IODEL I E NCAIGFA 26 1/2 20 HOOD INFORMATION MOOD HR 1 2 3 MODEL 4824 11D-BR 4224 VNH-G 3624 VHI-G EXMMUST PLENUM SUPPLY PLENUM FOOD CONSTRUCTION 304 SS BOX TODD COIfIG SVITCHES ON HOOD RISERS) ENG 26' 2775 *b17' 1806 i 750 VIBTI" LENGTH 9' =Non. 9' 325'® 5' 00011oia S' 0.50'0D 3' 0007NOoa 3' 0.50•00 MAX. COOKING MP. Deg 600 700 LS 700 Deg EXNL N 2775 750 450 10' I1• TaN 450 • 0264' 0180' 0 0 DiA. RISERS) LEM. CFI SP. ROV a1M1N11n I VIA 30E e d ALA FRONT I � ore RlgM 304 SS 101( END TO DID ALONE ALINE FRONT FRONT HOOD INFORMATION HOOD NO. I 2 3 FiLTER(S) TYPE OTT AHaninun Mesh 1 Nwi. Baffle r/ Handle 2 4 Madman Hesh 1 HEIGHT LENGTH 20' 20' 16' 20' 16' 12' 16' 12' on, MOOD TYPE 3 0 0 Incandescent Light UTILITY CAMEOS) V , ., TO FIR SYSTEM I ' MY NO nee PIPING YES NO To skieQII 591 LBS. 273 LBS. 163 LBS. PAGE 7 11000 OP110115 BACK RETURI1(5) A wi awls ims Ns o.an.___- - == — 1 1 I= `-= .1010 ODOBA - TUKVILLA 1440118 LN71C.A7 oti TUKVILLA, VA DATE 4/28/2006 JOB 440118 DWG I )08_440118 DRAWN BY 11!!9/. L00 SCAR 8.5' x 11' FAH INFO MATKO 1 FAiN OPTIC/Cs PAGE 8 CURB #65EMOUE5 M71E EXCESS SUPPLY CFA45 IWIL BEBROU 7/T THOROUGH COOLING Dlt l6t 5, f PROVIDED MOTHERS. GAS FIRED MN [ -1? MR Uini ELECTRICAL PACKAGES A � - - a -- � 'me LOCATION TUKVILIA, VA DATE 4/28/2006 CMGs ,(1B_440118 REV_ MI ODOBA - TUKVILLA 1440118 )1016/ 440118 I CRAM Iffr I SCALE 8$5 x 11' HCAFA SERIES UP8LA&T i`XHAUST FAITS (111.762) V PAGE 9 WIT DDIRNATIO . PAGE 10 NCAFA BELT IBtIVE CENTRW UGAL UP -BLAST OOWJST FANS DIIENSYDIAI. DATA MODULAR OUTDOOR DON41 DISCHARGE DIRECT ABED HEATER i i DIN 'B, T D IM 'N' I DINT J. 1 0 'R' DIN CUtB WALL OUTER-1 DIM 'P' DISCHARGE OPENING FLEX COMMIT FIR FIELD VIRING DIN 'F' AIRMEN 11111 'S' DIM 'C' 1 DIN ; 5 1- ' DUCTWtK BEM DN COMA RISER WI MOD ARID FAN (tY OTHERS) 40 ,_W ll rw = IfIV_ __ BLOWER/ MICR MEESS DE>di DIN 'H' FEATURES: - ROOF IMUNTED FANS - RESTAURANT IIEEI. - UL762 - AiIA SORW MO AiR CERTIFIED - VItING FRQI MOTOR TO DISCRDECT SVITCH - VEATIERPIOF DISCONNECT - HUGH HEAT OPER9ATHEBN 300'F (149•0 - GREASE CLASSIFICATION TESTING t w. TEMPERATURE TEST EXHAUST FIN MUST IFERATE CINTDNUO/SLY MILE EXIIMTSTBNG AiR AT 306'F (149'0 BOIL ALL FM PARTS HAVE REARED THE EQUILIBRIUM, AND WITHOUT NIT DETERIORATING EFFECTS TO THE FAN mum VOLD CAUSE UNSAFE O ERATDBI AIRNORIAL T I ARE-IP TEST EXHAUST FIN MUST OPERATE cI TINUO USLY %MILE E.)OIMJSTING BURNiING GREASE VAPORS AT 600'F (316'0 FOR APES OF 15 MOTES VITHWT THE FAN icaowiG DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE COOITQL OPTIONS: GREASE MC HQNCED FAN DIN 'A' SERVICE DISCIDRECT SVJ[TCH BIN 'T' DIRECT FRED E TO3 DIN 'K' ROOF IPENiNG 2' DIALLER 11E31 CMS BOENSI It /—LIFTING LUGS PLACES SLOPED FILTER INTAKE 20 IN MM EOU INIDIT CURB o k - A I -- _ IN a sAVOI∎ If VN.iIM* _ _ GIRD DDENSIOiAI DATA 3' FLANGE VENTED CURB 20 GAUGE STEEL CONSTRUCTION ROOF OPEMAG BDIENSIONS ..0010 ODOBA - TUKVILLA 11440118 LOCATION TUKVIILA, VA DATE 4/28/2006 DWG JO11_440118 REV. 1.00 - DIN IC' i,2,$ Ir.� � , : ,u CI\43, . I, U 1 IMFIM SWIM' -- - =1 MIME ----WAN © Mall MAN LallIMAM .�. � r ,: f?'FB'9 111 1 .% 7111 TL 1 TLi ti sI k' IriI• Ellti! [ rL1 LLIVAI I JOB ODOBA LOCATION T1J(V1UA, VA D6W 4/28/2006 a*G I J08_440118 REV. 1.00 JOB I 440118 DRAWN BY 5GiIf 8.5'x11' CURB/RAIL CORDiATiO N USED ON UNITS WITH 20' AND 25' BLOWERS 2D L sun EQUIPMENT DIN 'J' CURD t PAL - TUKVILLA 1440118 JOB/ 440118 DRAWN BY SCALE 8.5'x11' DUHFA SERIES IWCIAST EXHAUST FANS (UL7G2) V - ' I PAGE 11 G=R03' 2G DUN DIRECT DRIVE CENTRIFUGAL UP -BLAST EXHAUST FANS DDUFINS DAL DATA DUCTVINIC BETVEEIN E*IMUST RISER IN HOOD AND FIN (BY OTHERS) FEATURES: - ROOF MOUNTED FINS - RESTAURANT MODEL - UL762 - VAR1ABLE SPEED COMM_ - INTERNAL WIRING - VEATIERPROW DISCOBECT - THERMAL OVERLOAD PROTECTION (SINGLE PHASE) - HIGH HEAT O'ERATIRI 300'F (149'C) - GREASE CLASSWI:ATIO1 TESTING EXHAUST FAN MIST OPERATE CONTINUOUSLY VILE DOIiWSTING AiR AT 300'F 449'0 UNTIL ALL FM PARTS HAVE REAPED THERNN. EQUILINIUIL AND VTTIWT AHOY DETERBIRATITG EFFECTS TO THE FAN VIQCH VOLD CAUSE UNSAFE OPERATOR! ADDORDIL _f L :-Lp TEST EXHAUST FAN MIST OPERATE CONTO OUST.Y VILE ODAUSTDNG II R IMIG GREASE VAPORS AT 600'F MVO FOR A PERIOD OF 15 MINUTES VI1HWT TIE FAN DEMIQNG DAMAGED TO NIT EXTENT THAT CORD CAUSE AN UNSAFE aosonom. OPTIONS: GREASE 1m /MED FAN MI S —NHL- -- litionfitp = s mu II I/lV CURB DIEM SMU DATA .109 ODOBA - TUKVILLA 1440118 LOCATION TUKVILLA, VA DATE 4/28/2006 JOB I 440118 OM/ .108_440118 DRAWN BY RV. 1.0 Sour 8.5' DUHFA SERIES UPBIAST BCHNU`T FAITS (18762) V PAGE DUN DIRECT DRIVE COIIRIFLIGAL 11-BLAST EXHAUST FATS BIIENSEtDAL DATA r / voivotv. fG 1 41 -1'0 • DUCTWORK DEWED. o0UU14T RIiSER 1 1® NO FAN ay OTHERS) HV Engineering, Inc. Consulting Engineers 7100 linden Ave. N. Suite 1 G Seattle, Washington, 98103 www. Lvengineering. biz P1 atven (206) 7416 -966O Psr_ (2111) 71111-1130 FEATURES: - TRW MOUNTED FANS - RESTAURANT MODEL - 11.762 - VARIABLE SPEED COMM. - INTERNAL WIRDM - VEATHERPNEF MISDINECT - T1ERN AL OVERLOAD PROTECTION (SINGLE PHASE) - HEe, NEAT iPEERATiON 300T (149'0 - GREASE CLASSIFICATION TESTING IMMIJOI-IENDERDIMLIEBI EXHAUST FAN MIST OPERATE COJTRARIISLY VILE ODYUSTIL MR AT 300'F 04 UNTIL ALL FM PARTS HAVE REACHED TIE NAL E1mMBRIAN, NO VITHAUf ANY IEiEROtATDL EFFECTS TO THE FAN VFILTI VOULB CAUSE UNSAFE OPERAT®L RARLIA TEST ODWIST FM MAST APERATE C0i11MJIBBILY WHILE OGAUSIRL M I1IG GREASE VAPORS ATGOOF(316WOffERAPERIN - 15 MNRJTES VIDOtir THE FAIN DECIDING IMAGED AN E E COM THAT COULD CAUSE A 41111 a..MAI. ME-. -- - _ MEUSEcFOOaLErB PITCHED CURBS ARE AVAO.ABLJE FOR PITCHED ROOFS SPECIFY PITO, EXMHP1D 7/12 PiTCH = 30' S JWE CURB OOEI6NTIM. DATA JOB OIIOM JlOICAI WN TIBCVILLA, VA LNG I .AB 440118 DRAWN BY IHiS OOQJ1Ei01: me se IflWAS AND COIGNS INCORPORATED HEIRM. As AN IOSTRIDEIIT OF PROFESSIONAL SERAICE. IS THE PROFERTY OF WI EINGBNEEIBNI, , NC IVXD TS NOT TO 01 USED. E10 wIOIE OR N PART. FOR MY GRER PROJECT TIMM NE rL:FOlIO MINIMIZATION OF NV t7NQNEE1 CoPelG1L N0V ousaito t . UIOG - TUKVILLA 1440118 :m it 4/28/2006 1 JOB/ 440118 10.9/_ 1.00 SCALE 8S' x 11' RE si CITYOFTtI14'f1 t Ju t 13 P PtMT(ENTE.L 11BfY SCALE eAIR MEASURES ONE INCH ON ORIGINAL ORATING O' 1' F NOT ONE USD1 ON BANNS ORAMM MOAT SCALES AaooROINGLY. 152 W. Main St. Lena, IL 61048 P: (8 I 5) 369 -9155 F: (815) 369 -4495 J J EC 0 z U X W 2 'PROS. NO. 06W -O55 I 05/ I 610G I SHEET NUMBER M3.1 i • • BAR MFASORES ONE 1101 ON ORIGINAL SLUM F NOT ONE INCH ON NHS GRAMM ADJUST SCAMPS AoCOFOMNGiY Gns 1140 S r - • - -i24. FIRE SYSTEM - QDOBA - TUKWILLA 5/1/2006 7.5(000 -- PAGE 13 "Z-Z1; - 3:i E■ A.'Mp,MPL.. •tnaae =.e.i.u,si 3 SIM %x• c•• Se.• TS •a+S.W 116 ' c a •P* i -PGA; 3 is Se.%(c top rat =we Lq% • :T SCOW arox',g' fir. :► r s.b = C :os..v Got &oval M Aar ra S•ra 4...a.. >41.' -z uva6.ea G'o C ■v Gil c % UMX %Get p A°Mam SE soft al •01110. Maw =a lam! STINK 10003CL ]1O, f!3 AS !RAH RS WI L Sa ga. cots= AN - 10100. 531 5311 • I. RR WOOL Z•c54J..,e DRAWING NUMBER( C( \ACAD \FS PRPG \TXTFILES \QDOBATUKWILLAFIREFSD Job lb 440118 Job Nunes QDOBA - TUKVILLA 11440118 Drown ' System Size' 3.0/15 Total FP rewired( 14 Hood 11 1 9' Long x 48' Wide x 24' High Riser 1i 1 Sizes W x 26' DIES - FIELD PIPE DROPS AS SHOWN SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - MAXIMUM 9 ELBOWS IN SUPPLY LINE. - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE. - IF APPLICABLE, PRE -PIPED CHARBROILER DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6' ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS FACTORY PIPING FIELD PIPING G4Pf1VF NRE SYM MS ASSUMES RESPONSIBILITY FOR THE PRE -PIPING of IHE FIRE SYSTEM BASED UPON THE COOKING EQUIPMENT INFORMAITON WE R E C E I V E . I T I 5 THE CUSTOMERS RESPONSIBILITY T O 1 FY THE EQUIPMENT LOC 1T10N, 5PACMG, AND COOKING SURFACE DIMENSIONS. ItW CUSTOMER 15 RESPONSIBLE rog A DITI 1fAL CHARGES A5 A RESULT OF COOKING EQLNPMwrLAYOUT CHANGES AFlHR THE RELEASE OFAN moat UNION LABOR CHARGES, OR ADDITIONAL TRIPS MADE BY?WNW 5) 4 D15FRBUTOR CAUSED BYJOB SITE D13AY5. A.'1/4511L PM! STATION RrcTANL • LEGEND - WALL MOUNTED AHSUL SYSTEM IA 1.5 GALLON TANK I B 3.0 GALLON TANK 2 OEM AUTIIMAN RELEASE 3 3 GALLON TANK ENCLOSURE 3A 6 GALLON TANK ENCLOSURE 4 OEM REGULATED ACTUATOR 5 ANSULEX LIQUID AGENT (3 GAL.) 6 ANSULEX LIQUID AGENT (15 GAL.) 7 CARTRIDGE (101 -20) 8 CARTRIDGE (101 -10) 9 CARTRIDGE (101 -30) 9A CARTRIDGE (LT -A- 101 -30) 9B DOUBLE TANK CARTRIDGE 10 TEST LINK 11 DOUBLE MICROSWITCH 2W DUCT NOZZLE (419337) 1100 DUCT NOZZLE (430913) 1W NOZZLE ASSEMBLY (419336) 11 NOZZLE ASSEMBLY (419333) IN NOZZLE ASSEMBLY (419335) 1 /2N NOZZLE ASSEMBLY (419334) 3N NOZZLE ASSEMBLY (419338) 245 NOZZLE ASSEMBLY (419340) 230 NOZZLE ASSEMBLY (419339) 2120 NOZZLE ASSEMBLY (419343) 290 NOZZLE ASSEMBLY (419342) 260 NOZZLE ASSEMBLY (419341) 28 DETECTOR BRACKET 29 LOV TEMP FUSIBLE LINK 30 HIGH TEMP FUSIBLE LINK MGV MECHANICAL GAS VALVE EGV ELECTRICAL GAS VALVE 34 REMOTE MANUAL PULL STATION S SNIVEL ADAPTOR lIV Engineering, Inc. Consulting Engineers ® 7100 linden Ave_ N. Suite I O Seattle, Washington, 98103 ---- hcen ineerina biz Q' Powc: f 20 :OS - 91669 ray (206) 106 -i0 City REVIEWED FOR CODE COMPLIANCE A rt nr�ucf JUL 2 7 2006 qty' Of Tukwila I 9UILDiN(: nr►t5T(1N • • RECEIVE.) CAW (FTI WW1 tfl Jul 13 Pr PEWIT CENTEFI 152 W. Mann St. Lena, IL 6 1048 P: (81 5) 369 -9155 F: (8I 5) 369 -4495 poi. NO.: o6w -055 I !DATE os/ I G/a; • SHEET HUMBER M3.2