HomeMy WebLinkAboutPermit M06-151 - FLOORING STOREFlooring Store
17600 West Valley Hwy
M06 -0151
City t' Tukwila
Parcel No.: 2523049017
Address: 17600 WEST VALLEY HY TUKW
Suite No:
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: ci.tukwila.wa.us
Tenant:
Name: FLOORING STORE
Address: 17600 WEST VALLEY HY, TUKWILA WA
Owner:
Name: BROMEL DAVID K
Address: 3409 S LAURELHURST DR NE, SEATTLE WA
Contact Person:
Name: MIKE OSBORNE
Address: 8816 152 AV NE, REDMOND WA
Contractor:
Name: T E C MECHANICAL SERVICE CO.
Address: P.O. BOX 3550, REDMOND, WA
Contractor License No: TECMESC143BA
DESCRIPTION OF WORK:
CHANGE OUT ROOFTOP HVAC PACKAGE UNIT.
Value of Mechanical: $6,859.00
Type of Fire Protection:
Furnace: <100K BTU
>100K BTU
Floor Fumace
Suspended/Wall /Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat/Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
doc: IMC- Permit
MECHANICAL PERMIT
EQUIPMENT TYPE AND QUANTITY
0
0
0
0
0
1
0
0
0
0
0
0
0
0
* *continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 425 - 881 -3247
Phone: 206 881 -3247
Exp iration' Date: 02/01 /2007
Steven M. Mullet, Mayor
Steve Lancaster, Director
MO6 -151
08/03/2006
01/30/2007
Fees Collected: $235.00
International Mechanical Code Edition: 2003
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU 0
30 -50 HP/1,750,000 BTU 0
50+ HP/1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 0
Wood /Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment 0
M06 -151 Printed: 08 -03 -2006
Permit Center Authorized Signature:
doc: IMC- Permit
City oiri Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: ci.tukwila.wa.us
Print Name: ,t 44 / Oslo, n ?/
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Number: MO6 -151
Issue Date: 08/03/2006
Permit Expires On: 01/30/2007
Date: g -3-0
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction - orr the performance of w rk. I am authorized to sign and obtain this mechanical permit.
Signature: ¢_/� Date: CQ / ? �
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
M06 -151 Printed: 08 -03 -2006
i
CITY OF TUKWItA
1DEPT. OF COMMUNflY DEVELOPMENT
6300 SOUTHCEKIER BLVD.
TUKVV1LA, WA 98188
98188
1: ** *BUILDING DEPARTMENT CONDITIONS * **
PERMIT CONDITIONS
4: Readily accessible access to roof mounted equipment is required.
6: Manufacturers installation instructions shall be available on the job site at the time of inspection.
10: ** *FIRE DEPARTMENT CONDITIONS * **
14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051)
doc: Conditions
PERMIT CENTER
Parcel No.: 2523049017 Permit Number: M06 -151
Address' 17600 WEST VALLEY HY TUKW Status: ISSUED
Suite No: Applied Date: 07/14/2006
Tenant: FLOORING STORE Issue Date: 08/03/2006
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
8: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department
of Labor and Industries (206/248- 6630).
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned
in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051)
13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be
equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the
air - moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors
shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the
manufacturer's installation instructions. (IMC 606.1, 606.2.1)
15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051)
M06 -151 Printed: 08 -03 -2006
16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051)
17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
18: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: Conditions
* *continued on next page **
M06 -151 Printed: 08 -03 -2006
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work.
Signature:
Print Name:
doc: Conditions
0576 )rwei
Date:
M06 -151 Printed: 08 -03 -2006
CITY OF TUKWILA
Community Developmerrepartment
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
"Please Print"
SITE LOCATION
y � King Co Assessor's Tax No.: Z57,2 50490/ 7
Site Address: / 7C 00 4t Paley A t � eel it Suite Number: Floor:
Tenant Name: P /oe ,. t /nQ ort. — West Pine) New Tenant: ....Yes ❑..No
Property Owners Name: D 4+ v 9,■ en me, l r
Mailing Address: 3'/O1 0 rt . Lecv ao r<7'Vrgo / Se-ail LM 9 sy0S
City State Zip
Name: Mt Ice, 05 r n e ' TL C
Mailing Address: tt /C / 4 e, -ea"
E -Mail Address: In 0 5 r It & a Ct e.Ci ?7 t C l u, to
Company Name:
.VA
Building Pe.-,r,'o. ` rr
Mechanical Penult No. ter
Public Works Permit No
Project No.
(For once use only)
Day Telephone: YZS 8R/ _.S 2-''� 7
,C �.e✓rstt a,J • AM 98OSz
City State Zip
rcttcoIzFax Number: 42C Q 8.2- O2..2 6
GENERAL CONTRACTOR
ORMATION - (Mechanical Contractor information on back page)
Company Name: TEci 40-1 °ed Cher, ,oca ,5eri7IG Co,
Mailing Address: 6 W6 /S2'?' aag' K-G I77on4 L(JA 98o5.2,
J .. City State Zip
Contact Person: lithe. / Cs O or fled / Day Telephone: 'Sr ZS S'8I J2dl "I
E -Mail Address: tooStb rite) D1'-GJn y,o.2c Fax Number: Y25' P12 ozz6
Contractor Registration Number: 7E•f'CSC b€13 IA Expiration Date: o z /o,/ 7
"An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance"
ARCHITECT OF RECORD -All plans must be wet stamped by Architect of Record
Mailing Address:
State
Contact Person:
E -Mail Address:
our
Day Telephone:
Fax Number:
ENGINEER OF. RECORD —All plans must be wet stamped by Engineer of Record
Company Name: .2/,Q
Mailing Address:
State
Zip
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
tpennks pludicc changes tpermit application (7-2004)
Page 1
13UILIJIIY(r llr4rundue% LUba4.31- Jb
Valuation of Project (contractor's bid prick$ (I ( Existing Bt4fa"mg Valuation: $
ei 9
Scope of Work (please provide detailed information): ( fl d 0 v r 0 0 P al o p /7/1/4(
Will there be new rack storage? ❑ ..Yes ❑.. No If "yes ", see Handout No. for requirements.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq R): Floor area of principal dwelling: Floor area for accessory dwelling:
'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? . ❑ .... Yes ❑ ..No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
0.. Sprinklers ❑..Automatic Fire Alarm ❑..None
❑ . Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑.. Yes O.. No
If "yes ", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
%permits pka icc dunes\ permit application (MOM)
Page 2
Existing
Interior
Remodel
Addition to
Existing
Structure
New
Type of
Construction
per IBC
Type of
Occupancy per
IBC
I Floor
2" Floor
3' Floor
Floors - thru
Basement
Accessory Structure*
Attached Garage -
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
13UILIJIIY(r llr4rundue% LUba4.31- Jb
Valuation of Project (contractor's bid prick$ (I ( Existing Bt4fa"mg Valuation: $
ei 9
Scope of Work (please provide detailed information): ( fl d 0 v r 0 0 P al o p /7/1/4(
Will there be new rack storage? ❑ ..Yes ❑.. No If "yes ", see Handout No. for requirements.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq R): Floor area of principal dwelling: Floor area for accessory dwelling:
'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? . ❑ .... Yes ❑ ..No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
0.. Sprinklers ❑..Automatic Fire Alarm ❑..None
❑ . Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑.. Yes O.. No
If "yes ", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
%permits pka icc dunes\ permit application (MOM)
Page 2
I PUBLIC 'WORKS PERMIT INFORMATION — 206- 433 -0179
Scope of Work (please provide detailed in ormation):
❑...Total Cut
❑...Total Fill
1pamiu phn\icc change \pemk application (7-2004)
Call before you Dig: 1 -800- 424 -5555
Please refer to Public Works Bulletin q1 for fees and estimate sheet.
Water District
❑...Tukwila ❑... Water District #125
❑ ...Water Availability Provided
Sewer District
[]...Tukwila ❑...ValVue ❑..Renton ❑...Seattle
❑ ...Sewer Use Certificate ❑..- Sewer Availability Provided ❑ .. Approved Septic Plans Provided
❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department.
Submitted with Application (mark boxes which apply):
❑ ...Civil Plans (Maximum Paper Size -22" x 34 ")
❑...Technical Information Report (Storm Drainage)
❑ ...Bond ❑ .. Insurance ❑ .. Easement(s)
Proposed Activities (mark boxes that apply):
r] ...Right -of -way Use - Nonprofit for less than 72 hours
❑ ...Right -of -way Use - No Disturbance
❑ ...Construction/Excavation/Fill - Right -of -way
Non Right -of -way
cubic yards
cubic yards
❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank
❑ ...Cap or Remove Utilities ❑ .. Curb Cut
❑ ...Frontage Improvements ❑ .. Pavement Cut
❑...Traffic Control ❑ .. Looped Fire Line
❑ ...Backflow Prevention - Fire Protection ,,
Irrigation
Domestic Water "
❑...Permanent Water Meter Size... WO#
❑...Temporary Water Meter Size.. WON
o ...Water Only Meter Size WO#
❑...Sewer Main Extension Public Private
❑ ...Water Main Extension Public _ Private
Page 3
❑ .. Highline
❑ .. Geotechnical Report
CI ...Traffic Impact Analysis
❑ .. Maintenance Agreements) ❑...Hold Harmless
❑...Renton
❑ .. Right-of-way Use - Profit for less than 72 hours
❑ .. Right-of-way Use — Potential Disturbance
❑ .. Work in Flood Zone
❑ .. Storm Drainage
❑ .. Grease Interceptor
❑ .. Channelization
❑ .. Trench Excavation
❑ .. Utility Undergrounding
❑...Deduct Water Meter Size
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
❑ ...Water
❑ ...Sewer ❑ ...Sewage Treatment
Monthly Service Billine to:
Name: Day Telephone:
Mailing Address:
Ciry State Zip
Water Meter Refund/Billine:
Name: - Day Telephone:
Mailing Address:
City State Zip
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace<100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0-3 HP /100,000 BTU
Furnace>100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Water Heater
50+ HP /1,750,000 BTU
_
Repair or Addition to
Heat/Refrig/Cooling
System
Incinerator - Domestic
Emergency
Generator
Air Handling Unit
<10,000 CFM
Incinerator — Comm/lnd
Other Mechanical
Equipment
l
n /
Ro O.() 445 /? ci
MECHANICAL PERMIT TINFOR ATION -- 206- 431 -3670
MECHANICAL CONTRACTOR INFORMATION
Company Name: — rat. "lac A .2./z / Ceti /
Mailing Address: 88 a is- z eve stOC 2 eJnfon wA 9R0S"2
City State Zip
Contact Person: + 0.3 r' o t} L°J // Day Telephone: 4 125 -- ' 1t � t �2t( Z
E -Mail Address: /ne.S t�orne- , 0 &c0 mGdatdinca /. COfl Fax Number: 4•5 922 47226
Contractor Registration Number: TCC#1 &3 C. /4/38.4 Expiration Date: 0,220 0/2.0 O 7
• *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance**
q afro
Valuation of Project (contractor's bid price): $ 6559
Scope of Work (please provide detailed information): 64 a,n� p. o lit ro di' do t o I/ MC p die on it
Use: Residential: New -.0 Replacement ❑
Commercial: New ....0 Replacement.....
Fuel Type: Electric ❑ Gas ....g. Other:
Indicate type of mechanical work being installed and the quantity below:
PERMIT APPLICATION NOTES
A pplicable ttf all pertnits istk! aPPiicarioa ,
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as
defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER O UTHORIZE GENT:
J
Signature: i 'LIt412 )
/ �I Q d
Print Name: t t°, S o Day Telephone: 1 7 1 06 . �
Mailing Address: .Q d
\permits phuUce changatpermi appliation (7 -2004)
Page 4
Date:
jdg A,o man WA
City state
I Date Application Accepted:
1 1 Z*
Date Application Expires:
Staff Inif
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 2523049017 Permit Number: M06 -151
Address: 17600 WEST VALLEY HY TUKW Status: PENDING
Suite No: Applied Date: 07/14/2006
Applicant: FLOORING STORE Issue Date:
Receipt No.: R06 -01041 Payment Amount: 41.00
Initials: BLH Payment Date: 07/14/2006 01:30 PM
User ID: ADMIN Balance: $194.00
Payee: TEC MECHANICAL SERVICE CO
TRANSACTION LIST:
Type Method Description
Amount
RECEIPT
Payment Check 6348 41.00
ACCOUNT ITEM LIST:
Description
Current Pmts
PLAN CHECK - NONRES
Account Code
000/345.830 41.00
Total: 41.00
7392 37/14 9716 TOTAL 41.00
doc: Receipt Printed: 07-14-2006
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http.•Ilwww.ci.tukwila.wa.us
Parcel No.: 2523049017 Permit Number: M06 -151
Address: 17600 WEST VALLEY RY TUKW Status: ISSUED
Suite No: Applied Date: 07/14/2006
Applicant: FLOORING STORE Issue Date: 08/03/2006
Receipt No.: R08 -00002
Initials: JEM Payment Date: 01/02/2008 11:37 AM
User ID: 1165 Balance: 50.00
Payee: TEC MECHANICAL SERVICE COMPANY
RECEIPT
TRANSACTION LIST:
Type Method Description Amount
Payment Check 09454 58.00
ACCOUNT ITEM LIST:
Description
MECHANICAL - NONRES
Account Code Current Pmts
000/322.100 58.00
Total: $58.00
Payment Amount: 558.00
6694 01/02 9710 TOTAL 58.00
doe: Receiot -06 Printed: 01-02-2008
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 2523049017 Permit Number: M06 -151
Address 17600 WEST VALLEY HY TUKW Status: APPROVED
Suite No: Applied Date: 07/14/2006
Applicant: FLOORING STORE Issue Date:
Receipt No.: R06 -01176 Payment Amount: 194.00
Initials: BLH Payment Date: 08/03/2006 12:56 PM
User ID: ADMIN Balance: 80.00
Payee: TEC MECHANICAL
TRANSACTION LIST:
Type Method Description
Amount
RECEIPT
Payment Check 6450 194.00
ACCOUNT ITEM LIST:
Description
Current Pmts
MECHANICAL - NONRES
Account Code
000/322.100 194.00
Total: 194.00
8091. 03/03 9716 TOTAL 19/ on
doe: Receipt Printed: 08-03 -2006
Parcel No.: 2523049017
Address: 17600 WEST VALLEY HY TUKW
Suite No:
Tenant: FLOORING STORE
doc: Inspections
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
PERMIT INSPECTIONS
Description: CHANGE OUT ROOFTOP HVAC PACKAGE UNIT.
Permit Number: M06 -151
Status: FINAL
Applied Date: 07/14/2006
Issue Date: 08/03/2006
Item: 00701 ROUGH -IN MECHANICAL
01/19/2007 By: JD Action: CO Comments: CORRECTIONS / #2
1) ELECTRICAL ROUGH -IN NEEDED
Item: 00702 SMOKE DETECTOR SHUT -OFF TEST
01/30/2007 By: DL Action: CO Comments: CORRECTIONS / #1
1) NEEDS MONITORING
2) PRESSURE DIFFERENTIAL EQUIPMENT NEED TO COMPLETE TEST
Item: 06010 FIRE ALARM
07/24/2007 By: 512 Action: CO Comments: Detector failed to operate. Detector needs to be made
operational.
Item: 01400 FINAL - FIRE
01/08/2008 By: 510 Action: AP Comments: APPROVED/ #3
OK TO FINAL
l Item'n1RrlfRA 1 AI _MFr
12/28/2006 By: DL Action: CO Comments: CORRECTIONS / #1
1) HVAC SHUTDOWN TEST REQUIRED BUILDING & FIRE DEPARTMENT
2) GAS PIPING PERMIT?
3) ELEC PERMIT & INSPECTION
12/28/2006 By: DL Action: CO Comments: CORRECTIONS / #1
1) HVAC SHUTDOWN TEST REQUIRED BUILDING & FIRE DEPARTMENT.
2) GAS PIPING PERMIT?
3) ELECTRICAL PERMIT & INSPECTION
4) FIRE FINAL
01/30/2007 By: 512 Action: CO Comments: CORRECTIONS / #1
1) NEED MONITORING OF HVAC SHUTDOWN EQUIP
2) SUPERVISORY SIGNAL ON FAP
07/20/2007 By: 9999 Action: CA Comments: IVRS - RI canceled
07/24/2007 By: 9999 Action: CA Comments: IVRS - RI canceled
07/24/2007 By: 9999 Action: CA Comments: IVRS - RI canceled
07/24/2007 By: JD Action: CO Comments: CORRECTIONS / #3
1) SMOKE DETECTOR - FAILED TRIP TEST
2) PRESSURE DIFFERENTIAL - FAILED
REINSPECTION FEE OF $ 58.00 ASSESSED
01/08/2008 By: DL Action: CO Comments: CORRECTIONS / #4
1) NOT READY FOR HVAC SHUTDOWN TEST.
2) DETECTOR NOT LOCATED IN AIR STREAM.
3) PICK UP TUBE TOO SHQBT
2008 By: CM Action: AP Comments: APPROVED / #4
OK PER CAROL (APPLICANT BROUGHT IN INSP CARD TO VERIFY)
M06 -151 Printed: 09 -30 -2008
Project:
Roorineo Sror0
Type of Inspection:
AAPOIN. F:NPAI
Address:
17 Si) kt-&- i
Date Called:
C—
Special Instructions:
r 1 re bo _p er -p-e"1 --
- 1 - % A r c g 5cLu tli on k ,
f !?,A 5
tu VASI T, / A'
Date Wanted: ' - .nr
, . .
Requester:
Phone No: in; I il-
2 ot,- 510 -8kloo -
- TTI - C-P- t/Jim u
INSPECTI ON NO. INSPECTION RECORD
Retain a copy with permit 11 1, -1 51
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION JR
6300 Southcenter Blvd., #100, Tukwila, WA 98188 - (206)431-3670
Approved per applicable codes. Corrections required prior to approval.
( 5 I" -14/
C MENTS:
,
5 -1 ti
. - -
$58. INSPE E REQUIRED. Prior o inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
r eceipt No.:
'Date:
Project: n
1 — /CO i,J '
Sioe
Type of Inspection:
Ti�, /
Address:
1 760 : ,-)0 tut-s-/ V4 HE'/
Date Called:
r-1 v
Special Instructions:
$41 U I- c .._, 1 c_(f
r
in i
Dale Wanted:
'7 ig - c7
tA;m:
p.m.
Requester:
Phone No -,
200 5 (
°CAD
INSPE ON NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
mI / /fP /" /] / / 44( (' T ✓i
s -/.
7 / 5 5 / A(/
`o/ - ,rCve /4'!%
nspe t r: Date,
.00 REINSPECTION REO.UI Prior o inspection. fee must
id at 6300 Southcente� Sui a 100. Call the schedule
reinspection.
be
i p ion.
'Receipt No.: (Date:
1
„_ ...1/4 „ �J,. - - `t R. N'R K/'.
(206)431 -3670
Project::
Type of spection: i
v
Address:
1 7l C O Oe3-4 Ocklicv
Date Called:
4(44 )
Special Instructions: (
yy1; /CP
- 510 _ &5 5'
vv
Date Waned:
(— I -7
a
P.m.
Requester:
P hone No:
47 -C3 S( -32.
4 1
7
7
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable codes.
COMMENTS:
I
tor:
INSPECTION RECORD
Retain a copy with permit
ceL
Date:
PER
(206)431-
12 .Corrections required prior to approval.
CD
$ 00 REINSPECTION FEE REQU RED. Prio - o inspection, fee must be
at 6300 Southcenter Blvd., Suite 100; all to sechedule reinspection.
67
Receipt No.:
'Date:
Project:
Type of Inspection/ Wtf- -- )
Address : - —
7 0 . A ay � ��JJJJ
Date Called
Special Instructions: j
/
Date Wanted:
p m
!/ -30-07 a
Requester:
Phone No:
INSPECTION RECORD"
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable codes.
)431.3
I}tl Corrections required prior to approval.
COMMENTS:
15 A /Are r nn �vY
fic' $ '<TM f / -u/
fl $58:d9.4EINSPECTIO EE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southce er Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
(Date:
Project:
"Vi /),/
CA
Type of IIn /-�
/go Ati i , f . - ",,
Date Called:
Ad ress:
/.. 6,e, 9_
/t //s
Special Instructions:
/
Date Want C.�(�/ id.
2 -245?-
RequesteY:
Phone No:
yzs- M91- ,32.4')
LI Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
206)431 -3
pU Corrections required prior to approval.
COMMENTS:
l� 17/VA C 5 datar 4d- cif
v O
-► r 2
C $58.00 REINSPECT! FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
Date:
.41. _ •
Project:
Type of Inspection:
Address: 17 boo w. ..\ Vw»-.� A'k
Suite #:
Contact Person:
-- re(- Nike.c�c,,,,, c, \
Special Instructions:
Phone No.:
a z5 $ss — 3 2z*- - )
Needs Shift Inspection: qa, 0
Sprinklers: y. s
Fire Alarm: --
Hood & Duct: v1,V IA t_
Monitor: \,,- >
,a\ -, ,,,,._
Pre -Fire: w 0
Permits: \--F
Occupancy Type: ,re.,
444 Andover Park East. Tukwila, Wa. 98188 206 - 575 -4407
COMMENTS:
Inspector:: ;, �;\ J t
Date: l `$l DS
Hrs.:
INSPECTION NUMBER
Approved per applicable codes.
NSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA FIRE DEPARTMENT
rvi - 15 1
PERMIT NUMBERS
U Corrections required prior to approval.
$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Word /Inspection Record Form.Doc 1/13/06
T.F.D. Form F.P. 113
COMMENTS:
Sprinklers:
Type of Inspection:
[A cH
Address: i'7 6 oo
Suite #:
w . Q.\ 1-Lc
Kr<k{
rNAl,
- � FtC-(O 2
RAiurh `ro
o Pc - I2A7E
Phone No.:
`-125 -881 -37'17
— ---1 Thrm= c- t o
NEE OS _ID
bf MIA C
Project:
I 002
Sprinklers:
Type of Inspection:
[A cH
Address: i'7 6 oo
Suite #:
w . Q.\ 1-Lc
%-k
Contact Person:
1 E.C. W' c HAncICJ., -c—
Special Instructions:
Phone No.:
`-125 -881 -37'17
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire: - -
Permits:
Occupancy Type:
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA FIRE DEPARTMENT
1 Mo(fl - (Si
PERMIT NUMBERS
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
I I Approved per applicable codes.
corrections required prior to approval.
Inspector:
Date: /z N i,o +
Hrs.: j
n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Word /Inspection Record Form.Doc 1/13/06
T.F.D. Form F.P, 113
Project: Hai FA JA <I.cti Rus. 41-12-,i_
Type of Inspection:
MECH Nock,
Address: 13 Goo vJ . VA Lit 4
Suite #:
Contact Person:
M „c E
Specii l Instructions:
Phone No.:
4zs 8e1 - L 3.
Needs Shift Inspection:
Sprinklers: /
Fire Alarm:
Hood & Duct:
Monitor:
Pre-Fire:
Permits:
Occupancy Type:
3. f
INSPECTION NUMBER
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
n Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA FIRE DEPARTMENT
Mob- ISI
PERMIT NUMBERS
Corrections required prior to approval.
7
COMMENTS:
C) bIEN) IvtoNi n_ 4G I +J c. S 11- 0rboviN E.&JIP
(7) Supt vi4rov4 S16NAc otici P•
l
I
Inspector: 4 I)
Date: / 30 / 0
Hrs.: I
$80.00 REINSPECTION FEE REQUIRED. You will rftceive an invoice from
e City of Tukwila Finance Department. Call to schedule a ?inspection.
1/13/06 / T.F.D. Form F.P. 113
Word /Inspection Record Form.Doc
ROMA NORTH VALLEY BLOCK LOAD
HVAC Load Analysis
p ....» r1. o
for
MR. DAVID BROMEL
17660 W VALLEY HWY
TUKWILA, WA 98188
FILE COPY
CHVAC COMMERCIAL
HVAC LOADS
I REVIEWED FOR
CODE COMPLIANCE
fr nay, A*,
JUL 2 , -
Of Tukwila
RI III Mir nil nTCTfTl
RECEIVED
CITY OF TUKWI A
JUL 1 4 2006
PERMIT CENTER
Prepared By:
Getinet Alewab
TEC Mechanical
8816 152nd Ave. NE
Redmond, WA 98052
425- 881 -3247
07/07/06
o rams r ' " oa s acuta4oriProgram
ecMechan
;. se I �" I :
fi
ill
fte ere reveoilmen
General Project Data Input
enera -ro ec1'; n or .bon
Project file name:
Project title:
Designed by:
Project date:
Project comment:
Project location:
Client name:
Client address'
Client city:
Client phone:
Client fax:
Client comment:
Company name:
Company representative:
Company address*
Company city:
Company phone:
Company fax:
Company comment:
Barometric pressure:
Altitude:
Latitude:
Mean daily temperature
Starting & ending
Floor heat loss
Number of unique
u drn. De
Calculations performed:
Lighting requirements:
Equipment requirements:
People sensible
People latent load
Zone sensible
Zone latent safety
Zone heating
People diversity
Lighting profile
Equipment profile
People profile
Building default
Building default
me na speratingEoa
range:
time for HVAC load calculations:
coefficient:
zones in this project:
au t a ues
load multiplier:
multiplier:
safety factor:
factor:
safety factor:
factor:
number:
number:
number:
ceiling height:
wall height:
raffles
P:AMy Documents \Project Archive\2006 Projects \Northvalley
Roma \Load calc\Zone Block Load.CHV
ROMA NORTH VALLEY BLOCK LOAD
Getinet Alewab
07/07/06
This is a heating and cooling block load to determine the
unit.
TUKWILA
MR. DAVID BROMEL
17660 W VALLEY HWY
TUKWILA, WA 98188
TEC Mechanical
Getinet Alewab
8816 152nd Ave. NE
Redmond, WA 98052
425 - 881 -3247
425 -882 -0226
29.867 in.wg.
50 feet
47 Degrees
26 Degrees
8am - 9pm
0.64 Btuh per foot of slab
1
Both heating and cooling loads
1.90 Watts per square foot
1.00 Watts per square foot
250 Btuh per person
200 Btuh per person
10 %
10 %
10 %
100 %
1
1
1
8.3 feet
10.0 feet
-
correct AC
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
hr
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
1
2
3
4
5
6
7
8
9
10
C
C
C
C
C
C
C
c
C
C
C
C
C
C
C
C
C
c
C
C
C
C
C
C
C
C
C
c
C
C
C
C
C
C
C
C
C
c
cm
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
c
C
C
C
C
C
c
C
C
C
C
c
C
C
C
C
C
C
C
C
C
c
C
C
C
C
C
C
C
C
c
c
C
C
C
C
C
C
C
C
c
c
C
C
C
C
C
C
C
C
c
c
C
C
C
C
C
C
C
C
c
c
c
C
C
C
C
C
C
C
C
c
c
C
C
C
C
C
C
C
c
c
c
C
C
C
C
C
C
C
c
cm
c
C
C
C
C
C
C
C
C
c
C
C
C
C
C
C
C
C
C
c
C
C
C
C
C
C
C
c
C
C
C
C
C
C
C
C
C
C
c
C
C
C
C
C
C
C
C
c
c
c
C
C
C
C
C
C
C
c
c
c
C
C
C
C
C
C
C
C
c
C
Friday, July 07, 2006
' on Program
NORTWVAILL
Afir/Priristit•Pr'
:47:61.0
Az*
General Project Data Input (cont'd)
.ettit.in.. eve' iest.n
"'".4;.,'$
Design
Month
August
June
July
September
January
February
Winter
1, - •
Roof
No.
1
arrtnAli.ta..
Wall
No.
1
MMt4 PMti
Partition
No.
1
Shade
No.
Dist
Horiz
Overh
Projects
4.00
4.00
Outdoor
Dry Bulb
86
88
89
80
54
59
24
Dist
Beyond
Right
W.Edge
5.00
1.00
ASHRAE
Roof#
4
ASHRAE
Group
B
Outdoor
Wet Bulb
68
66
69
65
48
50
Indoor
Rel.Hum
50%
50%
50%
50%
50%
50%
Roof
U-Fac
0.060
Wall
U-Fac
0.075
Glass Summer Winter Glass Interior
No. U-Factor U-Factor Shd.Coef. Shading
1 0.430 0.360 1.000 1
2 0.430 0.360 1.000 1
3 0.430 0.360 1.000 1
4 0.430 0.360 1.000 1
Interior
Shd.Coef
0.530
0.530
0.530
0.530
Indoor
Dry Bulb
78
78
78
78
75
75
70
Dark
Color
No
Wall
Color
M
Room Glass
Const Width
M 9.580
M 3.000
M 4.000
M 3.500
- f aster a• in • :vices
Dist Dist Dist
Beyond Overh Right
Left Above Fin
W.Edge Wind Proj
1.00 0.50 4 00
12.00 0.50 4.00
Dist
fl-Fin
Beyond
W.Edge
5.00
0.50
Ht
Of
Right
Fin
2.83
9.00
Dist
Left
Fin
Proj
4.00
4.00
Grains
Diff
2.23
-11.15
2.65
-3.23
-24.70
-25.59
Susp.
Cell
Dist
L-Fin
Beyond
W.Edge
1.00
12.00
In/Outdoor
Correction
-12
-10
-9
-18
-41
-36
No
Glass
Height
2.830
9.000
6.000
5.000
Ht
Of
Left
Fin
2.83
9.00
Friday, July 07, 2006
Friday, July 07, 2006
AC cults ommer6fat kVAC Coach Cstoutat program
'Tec Mechanlcaf - .z;;
edmand,INA $8052.3863° . . .: ., . _ _
...
re L7 eiop attt, lrkc
.: t ftotrtactuo t t~ ^ Bt�„OCtfi br g
_ . •r e.,„ '',v%v '.�- iw =. '° t. `w' ' e` `'r
Zone Input
24 s. - .eGt'i .=
Air Handler number: 1
Zone length: (feet) 2,450.00
Lighting Watts: 4,655
Number of people in zone: 10
Lighting profile number: 1
Ceiling height (feet): 9
Sensible safety factor ( %): 10
Sensible heat per person (Btuh): 250
Cooling ventilation method: CFM /Pr
Cooling infiltration method: AC /Hr
Heating ventilation method: CFM /Pr
Heating infiltration method: AC /Hr
Winter exhaust air CFM: 50
Minimum supply CFM: 0
Ceil. exposed to plenum (sq.ft): 2,450
Both heating and cooling loads are calculated for this zone.
Roof Type ASHRAE# U- Factor
Zone occurrences:
Zone width (feet):
Equipment Watts:
People profile number:
Equipment profile number:
Heating safety factor ( %):
Latent safety factor ( %):
Latent heat per person (Btuh):
Cooling ventilation value:
Cooling infiltration value:
Heating ventilation value:
Heating infiltration value:
Summer exhaust air CFM:
Latent Btuh equipment load:
Exposed floor slab perimeter (sq.ft):
Dark Length Width Area
1
1.00
2,450
1
1
10
10
200
20.000
0.850
20.000
0.850
50
0
31
Susp.Ceil
1 1 4 0.060
Part Type U- Factor Cool TD
No 2,450.00 1.00 2,450.0
Heat TD Height Width
No
Area
2 1 0.42 12.000
3 2 0.07 10.000
Wall Type ASHRAE# U- Factor
15.000 12.00 100.00
1 5.000 36.00 31.33
Color Height Width Area
1,200.0
1,1 27.9
Direction
1 1 B 0.075
4 1 B 0.075
Glass Type S.0 -F. Shd C. Height
M 12.00 31.33 376.0
M 10.00 65.00 650.0
Width Quan Area Shade Tilt
N
W
Ref
1 1 0.430 1.000 2.83
2 2 0.430 1.000 9.00
3 3 0.430 1.000 6.00
4 4 0.430 1.000 5.00
9.58 3.000 81.3 1
3.00 1.000 27.0 2
4.00 5.000 120.0 0
3.50 5.000 87.5 0
90
90
90
90
1
1
4
4
Friday, July 07, 2006
' H *• - y�� u � oai nrerc AG oa•s aicutaftorr rogram
ec tY,evhan cal , w vF'. 3
ed ond 'ONA, 88521663.
d ' i s
� OTNa
fa mare uetcp� c
i 2 A t
ktV .:,fir
Building Summary Loads
Building peaks in July at 4pm.
e .g'toag ea" , err %Tot Lat
t
p � L�te� a
1Desc lt:47o s � : Quart �:. _, _,bass,., ..� Loss
Roof 2,450 7,438
12.95 0 3,891
3,891
4.88
Wall 710 2,695
4.69 0 137
137
0.17
Glass 316 5,753
10.02 0 23,728
23,728
29.76
Floor Slab 31 1,015
1.77 0 0
0
0.00
Skin Loads 16,901
29.42 0 27,756
27,756
34.81
Lighting 4,655 0
0.00 0 17,472
17,472
21.91
Equipment 2,450 0
0.00 0 9,196
9,196
11.53
People 10 0
0.00 2,200 2,750
4,950
6.21
Partition 2,328 9,619
16.75 0 7,521
7,521
9.43
Cool. Pret. 0 0
0.00 0 0
0
0.00
Heat. Pret. 0 0
0.00 0 0
0
0.00
Cool. Vent. 200 0
0.00 580 2,196
2,776
3.48
Heat. Vent, 200 9,918
17.27 0 0
0
0.00
Cool. !nth. 312 0
0.00 912 3,856
4,768
5.98
Heat Infil. 312 17,040
29.67 0 0
0
0.00
Draw -Thru Fan 0 0
0.00 0 0
0
0.00
Blow -Thru Fan 0 0
0.00 0 786
786
0.99
Reserve Cap. 0 0
0.00 0 0
0
0.00
Reheat Cap. 0 0
0.00 0 0
0
0.00
Supply Duct 0 2,640
4.60 0 3,609
3,609
4.53
Return Duct 0 1,320
2.30 0 902
902
1.13
Building Totals 57,438
100.00 3,692 76,044
79,736
100.00
ui . ng Seaso
Lat ., as f
et
xa
et
umma Loss i_
oss
Gain ,
Ventilation 9,918
17.27
580 2,196
2,776
3.48
Infiltration 17,040
29.67
912 3,856
4,768
5.98
Pretreated Air 0
0.00
0 0
0
0.00
Zone Loads 26,520
46.17
2,200 64,695
66,895
83.89
Plenum Loads 0
0.00
0 0
0
0.00
Fan & Duct Loads 3,960
6.89
0 5,298
5,298
6.64
Building Totals 57,438
100.00
3,692 76,044
79,736
100.00
c
Total Building Supply Air (based on a 20° TD):
3,287 CFM
Total Building Vent. Air (6.08% of Supply):
200 CFM
Total Conditioned Air Space:
2,450 Sq.ft
Supply Air CFM /Sq.ft Of Conditioned Space:
1.3417 CFM /Sq.ft
Sq.ft Of Conditioned Air Space Per Ton:
368.7154 Sq.ft/Ton
Tonnage Per Sq.ft Of Conditioned Air Space:
0.0027 Tons / Sq.ft
Total Heating Required With Outside Air:
57,438 Btuh
Total Cooling Required With Outside Air:
6.64 Tons
Friday, July 07, 2006
Air Handler #1 Summary Loads
1
Office Spaces
4pm June
2,450
10
22,050
43,560
1,224
0.50
68,577
3,287
1.34
-108
50
50
20 /P
200
200
20 /P
200
200
Zone Peak Totals: 2,450 43,560 68,577 -108
Total Zones: 1 10 1,224 3,287 50 200 200
Unique Zones: 1 22,050 0.50 1.34 50 200 200
Friday, July 07, 2006
"' • ; d ° oM meratat 'T r oath a c ort rognun , � f 3 v
re Re ot7
ec?:d echank2l . F z' a ( rsk14M KIQRT1k,C.�
t;...JUS.x A ..- :.2:.BB:t >,r... ^ a ' .. ,, ' a ; .
dH
Air Handler #1 Total Load Summary
Air Handler Description: AC -1 Office Spaces Constant Volume - Proportion
Supply Air Fan: Blow -Thru with program estimated horsepower of 0.31 HP
Fan Input: 0% motor and fan efficiency with 0 in. water across the fan
Sensible Heat Ratio: 0.96 - -- This system occurs
Air System Peak Time: 4pm in July.
Outdoor Conditions: 88° DB, 69° WB, 75.57 grains
Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in
the total system peak time, hence the air system CFM was computed using a zone sensible
Summer: Ventilation controls outside air, Winter: Ventilation controls outside air.
Zone Space sensible loss: 26,520 Btuh
Infiltration sensible loss: 17,040 Btuh 312 CFM
Outside Air sensible loss: 9,918 Btuh 200 CFM
Supply Duct sensible loss: 2,640 Btuh
Return Duct sensible loss: 1,320 Btuh
Return Plenum sensible loss: 0 Btuh
Total System sensible loss:
Heating Supply Air 46,199 / (.998 X 1.08 X 35) = 1,224 CFM
Winter Vent Outside Air (16.3% of supply) = 200 CFM
Zone space sensible gain: 64,695 Btuh
Infiltration sensible gain: 3,856 Btuh
Draw -thru fan sensible gain. 0 Btuh
Supply duct sensible gain: 3,609 Btuh
Reserve sensible gain: 0 Btuh
Total sensible gain on supply side of coil:
Cooling Supply Air: 76,042 / (.998 X 1.1 X 20) = 3,287 CFM
Summer Vent Outside Air (6.1% of supply) = 200 CFM
Return duct sensible gain: 902 Btuh
Return plenum sensible gain: 0 Btuh
Outside air sensible gain: 2,196 Btuh 200 CFM
Blow -thru fan sensible gain: 786 Btuh
Total sensible gain on return side of coil:
Total sensible gain on air handling system:
1 time(s) in the building. - --
June at 4pm is different from
load of 68,577.
57,438 Btuh
72,160 Btuh
3,884 Btuh
76,044 Btuh
3,692 Btuh
79,736 Btuh
Zone space latent gain. 2,200 Btuh
Infiltration latent gain: 912 Btuh
Outside air latent gain: 580 Btuh
Total latent gain on air handling system:
Total system sensible and latent gain:
het pure
> . i
Total Air Handler Supply Air (based on a 20° TD): 3,287 CFM
Total Air Handler Vent. Air (6.08% of Supply): 200 CFM
Total Conditioned Air Space: 2,450 Sq.ft
Supply Air CFM /Sq.ft Of Conditioned Space: 1.3417 CFM /Sq.ft
Sq.ft Of Conditioned Air Space Per Ton: 368.7154 Sq.ft/Ton
Tonnage Per Sq.ft Of Conditioned Air Space: 0.0027 Tons /Sq.ft
Total Heating Required With Outside Air: 57,438 Btuh
Total Cooling Required With Outside Air: 6.64 Tons
Friday, July 07, 2006
06 -05 -2008
MIKE OSBORNE
8816 152 AV NE
REDMOND WA 98052
RE: Permit No. M06 -151
17600 WEST VALLEY IIY TUKW
Dear Permit Holder:
City of Tukwila Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for
additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 07/06/2008 , your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Cr Marshall,
Permit Technician
xc: Permit File No. M06 -151
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
12 -11 -2007
MIKE OSBORNE
8816 152 AV NE
REDMOND WA 98052
RE: Permit No. M06 -151
17600 WEST VALLEY HY TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for
additional periods not exceeding 90 days each. Extension requests must be In wrltin, and provide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 01/20/2008, your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
xc: Permit File No. M06-151
City of Tukwila
Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206-431-3665
06-04 -2007
MIKE OSBORNE
8816 152 AV NE
REDMOND WA 98052
RE: Permit No. M06 -151
17600 WEST VALLEY BY TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for
additional periods not exceeding 90 days each. Extension requests must be In writing and provide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 07/29/2007 , your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
er Marshall,
Permit Technician
we: Permit File No. M06.151
Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665
12 -06 -2006
MIKE OSBORNE
8816 152 AV NE
REDMOND WA 98052
RE: Permit No. M06 -151
17600 WEST VALLEY HY TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to
Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for
additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 01/30/2007 , your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Aka
r M rshall,
Permit ician
xc:
Permit File No. M06 -151
City of Tukwila
•
Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
•
•
•
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665
DEPARTMENTS:
sm
Bui 'i ng Division
Public Works ❑
Complete Ti
Comments:
PERMIT COORD COPY �g
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M06 -151 DATE: 07 -14 -06
PROJECT NAME: FLOORING STORE
SITE ADDRESS: 17600 WEST VALIeY HY
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
Sit *VC/ --
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete J
Planning Division
❑ Permit Coordinator
DUE DATE: 07 -18-06
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route Ni l Structural Review Required ❑ No further Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Notation:
REVIEWER'S INITIALS:
Documems/roming slip.doc
2 -28 -02
Approved with Conditions
DATE:
DATE:
n
DUE DATE: 0$-15-06
Not Approved (attach comments) ❑
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
TECMESC143BA
Licensee Name
T E C MECHANICAL SERVICE CO
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
600291892
Ind. Ins. Account Id
Business Type
CORPORATION
Address 1
PO BOX 3550
Address 2
City
REDMOND
County
KING
State
WA
Zip
980733550
Phone
4258813247
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
1/1/1986
Expiration Date
2/1 /2007
Suspend Date
Separation Date
Parent Company
Previous License
BBMECS* I 92MU
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
FRANCIS, CHARLES D
01/01/1980
BALDWIN, JOAN M
01/01/1980
Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Bond Information
Bond
#8
Bond
Company
Name
AMERICAN
STATES
INS CO
Bond Account
Number
6350122
Effective
Date
05/24/2005
Expiration
Date
Until
Cancelled
Cancel
Date
Impaired
Date
Bond
Amount
$12,000.00
Received
Date
05/23/2005
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= TECMESC 143BA 08/03/2006
MECHANICAL LEGEND
SYMBOL
ABREVIATION
DESCRIPTION
SYMBOL
ABREVIATION
DESCRIPTION
fliil
POC
POINT OF CONNECTION
)
N/A
DUCT /PIPE /STRUCTURE
DISCONTINUITY
;;. OR X
DEMO
DEMOLISH /DEMOLITION
IPLV
SA
SUPPLY AIR
-
TOTAL
MBH
RA
NEW RA DUCTING
--}'fir
RA
RETURN AIR
VOLTS /PH /HZ
MCA
SA
NEW SA DUCTING
--- Nr
O.A.I.
OUTSIDE AIR INTAKE
OFFICE SPACE
TRANE
N/A
(E) UNLINED DUCT ("RA". "SA" OR "OA ")
N/A
OA
OUTSIDE AIR
2.0
-
N/A
NEW CONDENSATE DRAIN LINE
N/A
GA,
GAUGE
--i
N/A
NATURAL GAS LINE W/ GAS BALLCOCK
N/A
DEMO
DEMOLISH
V l i
N/A
N.E.C. /SERVICE OR OPERATIONAL
CLEARANCE
N/A
EXIST. / (E)
EXISTING
N/A
MECHANICAL EQUIPMENT
N/A
DN
DOWN
1
VD
VOLUME DAMPER
N/A
EXH.
EXHAUST
N/A
ROUND DUCT OR PIPE UP
N/A
P.T.
PRESSURE TREATED
N/A
ROUND DUCT OR PIPE DN
N/A
T.V.
TURNING VANES
C
Zn
N/A
RECTANGULAR DUCT SA UP
N/A
CFH
CUBIC FEET PER HOUR
N/A
RECTANGULAR SA DUCT DOWN
N/A
W.C.
WATER COLUMN
N/A
RECTANGULAR RA DUCT UP
N/A
N.G.
NATURAL GAS
N/A
RECTANGULAR RA DUCT DOWN
N/A
GALV.
GALVANIZED
0
DIA.
DIAMETER
N/A
S. MTL
SHEET METAL
GAS HEATING ELECTRIC COOLING UNIT SCHEDULE
NUMBER
AREA SERVED
MAKE
MODEL
SUPPLY FAN
COOLING COIL
HEAT EXCHANGER
ELECTRICAL
MISCELLANEOUS DATA
CFM
MIN. OA
EXTERNAL S.P.
(IN. W.G.)
RPM
HP
EER
IPLV
EDB
EWB
SENS.
MBH
TOTAL
MBH
TOTAL
CFM
EDB
MBH
INPUT
MBH
OUTPUT
AFUE
( %)
VOLTS /PH /HZ
MCA
MOCP
SOUND (dB)
WEIGHT
REMARKS
GP -1
OFFICE SPACE
TRANE
YSC090A4RLA0001
3000
600
0.7
936
2.0
10,1
-
81.0
65.4
74.2
91.6
3000
59.4
120/84
97.2/68
81
460/3/60
22.6
35
90
820
1,2,3
APPROX. 125 FEET
/
1. PROVIDE WITH MANUFACTURER'S ROOF CURB.
2. ELECTRICAL DISCONNECT, POWER WHIP EXTENSION AND CONVENIENCE OUTLET TO BE PROVIDED BY OTHERS.
3. PROVIDE W/ MANUFACTURER FURNISHED 0% TO 100% ECONOMIZER,
LEGAL DESCRIPTION /PARCEL NUMBER
LEGAL DESCRIPTION: 252304 17S 329.85 FT OF GL 7 LY BET PST &P R/W & CO RD LESS ST HWY
PARCEL NUMBER: 2523049017
KING COUNTY ZONING DESIGNATION: C /L1
SCOPE STATEMENT
DEMOLISH (1) EXISTING 7.5 -TON HEAT PUMP UNIT AND INSTALL (1) NEW 7.5 -TON TRANE GAS /ELECTRIC UNIT W /ADAPTOR CURB, ECONOMIZER, AND
SMOKE DETECTOR. EXTEND EXISTING NATURAL GAS LINE TO RECONNECT TO NEW UNIT, CONDENSATE DRAIN LINE, CONTROLS AND POWER WIRING.
N APPROX. 130 FEET
l
VICINITY /SITE MAP
SCALE: 1" = 40' ^0"
\OTE(S):
PROPERTY /BUILDI
APPROX. 740 FEET
G LINES A
D
DI
V
ENSIO
BUILDING OUTLINE
S ARE TAKEN
FRO
V
KING COU
PIN 2523049017
UTY
51
VAP SATELITE PHOTO DATA & HELD
V
EASURE
VENTS
mow
S ° ARATIE PERMIT
gEQUZ D FOR:
Cl Mechanical
'
0 Plumbing
Cl Geis Piping
City of Tukwila
1ILDING DIVISION
RE \II`E' l \! D R
11II CODE COOPI ;At \1C r
e,11r ?a
FILE Coil
Permit No. M ' / + f• I
Plan review approval Is subject to errors and omission&
Approval cf can ::ruction documents does not authorize
the violation c �..:� ccpc; �cd code or ordinance. Receipt
of approved F;c : :; C.; y c.:-,) cond :tions i9jacknowledged:
By
y
City of lbkwila
BUILDING DIVISION
No changes shall b mad y to the sco > +r;
c c1 O! without prior approval of
Tz. °a.fisii � Building Division.
NOTE: F:evis cns w :;; require a new plan submittal
and may include additional plan review fees.
Mo tsi
C6
U
■11
C6
0
N
U
w
1—•
SHEET TITLE:
REVISION
# TITLE
LEGEND, SCHEDULE
NOTES, VICINITY
MAP, SCOPE
STATEMENT & LEGAL
DESCRIPTION
Q
a
N o
w z
z O��
i— co
D5zco
im T
�
00. Wa,
w J a
�� > IRS
0
MOSk
02Nmin
Zy�I-
DRAFTED: GBA
DESIGNED: GBA
CHECKED: GBA
PERMIT ISSUE
INITIALS
ti
0
00
rn
7
0
- 0
a�
M1 /2
DATE
07/07/06
ROOF PARAPET
HVAC PARTIAL ROOF DEMO PLAN
(E) ELECTRICAL
DISCONNECT TO REMAIN
DEMO (E) HEAT PUMP
UNIT
� GP-1 ON ROOF
SCALE1 1/8' =1' -0'
A -A HVAC PARTIAL ELEVATION
ROOF PARAPET
ROOF (BEYOND) —\
II
GP -1 ON ROOF
HVAC PARTIAL ROOF PLAN
SCALE' 1/8 " =1' -0'
29' -3"
EXTEND NEW 3/4" N. GAS
d TO NEW GP -1
L7
Q RECONNECT (E) ELECTRICAL
L7
TO NEW UNIT
0(0 5
KEY PLAN
SCALE
4r rt)
COD �. a10
KW
100TH CORPORATION
INITIALS
DRAFTED:
GBA
DESIGNED:
GBA
CHECKED:
GBA
REVISION
#
TITLE
DATE
PERMIT ISSUE
07/07/06
M2/2
ROOF PARAPET
HVAC PARTIAL ROOF DEMO PLAN
(E) ELECTRICAL
DISCONNECT TO REMAIN
DEMO (E) HEAT PUMP
UNIT
� GP-1 ON ROOF
SCALE1 1/8' =1' -0'
A -A HVAC PARTIAL ELEVATION
ROOF PARAPET
ROOF (BEYOND) —\
II
GP -1 ON ROOF
HVAC PARTIAL ROOF PLAN
SCALE' 1/8 " =1' -0'
29' -3"
EXTEND NEW 3/4" N. GAS
d TO NEW GP -1
L7
Q RECONNECT (E) ELECTRICAL
L7
TO NEW UNIT
0(0 5
KEY PLAN
SCALE
4r rt)
COD �. a10
KW