Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M06-180 - RREEF MANAGEMENT - BUILDING 32
RREEF - BUILDING 32 1034 INDUSTRY DR M06 -180 f rl 1,/yo, A DEPT. OF CG..::. :::• i Y L .. _ '.f 6300 TUKWILA, WA' vD. 98188 Parcel No.: 2523049071 Address: 1034 INDUSTRY DR TUKW Suite No: Tenant: Name: RREEF, BUILDING 32 Address: 1034 INDUSTRY DR, TUKWILA WA Owner: Name: CALWEST INDUSTRIAL PROP Address: C/O DELOITTE & TOUCHE LLP, 2235 FARADAY AVE #O Contact Person: Name: PETER CRELLEY Address: PO BOX 33370, SEATTLE WA Contractor: Name: PRO STAFF MECHANICAL INC Address PO BOX 33370, SEATTLE WA Contractor License No: PROSTMI072NG DESCRIPTION OF WORK: CHANGE OUT: REPLACE EXISTING 4 -TON AC UNIT WITH A NEW TRANE 4 -TON UNIT Value of Mechanical: $7,600.00 Type of Fire Protection: Furnace <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 **continued on next page** Permit Number: Issue Date: Permit Expires On: ^"'^TER Phone: Phone: 206 361 -0071 Phone: 206 - 361 -0071 Expiration Date:06 /30/2008 M06 -180 08/24/2006 02/20/2007 Fees Collected: $246.53 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 1 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU 0 30 -50 HP/1,750,000 BTU 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 doc: IMC- Permit M06 -180 Printed: 08-24 -2006 (; ITY (V Tt I!n ^IA DEPT. C CC. :, +r' C_.'_ . 6300 CL.UTfitCL :NiL UV TUKWILA, WA 96168 Permit Center Authorized Signature: I hereby certify that I have read and Signature: ordinances governing this work will be mp ith, whether specified herein or not. PERMIT CENTER Permit Number: M06 -180 Issue Date: 08/24/2006 Permit Expires On: 02/20/2007 40k040 Dater('µ/, k s permit and know the same to be true and correct. All provisions of law and The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the, perf yyrynance of work. I am authorized to sign and obtain this mechanical permit. Date: e/I2-11 /06 v S p c LPIV ) Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: 'MC- Permit M06 -180 Printed: 08 -24 -2006 Parcel No.: 2523049071 Address: 1034 INDUSTRY DR TUKW Suite No: Tenant: RREEF, BUILDING 32 City ckeTukwila 1: ***BUILDING DEPARTMENT CONDITIONS*** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us PERMIT CONDITIONS 4: Readily accessible access to roof mounted equipment is required. doe: Conditions **continued on next page" Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -180 Status: ISSUED Applied Date: 08/17/2006 Issue Date: 08/24/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. M06 -180 Printed: 08-24 -2006 Signature: Print Name: S doc: Conditions City dr'Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: 2- f Z 4 /06 M06 -180 Printed: 08 -24 -2006 { SITE LOCATION King Co Assessor's Tax No.: 25 049071 Site Address: 1031 LL INDI .S1Rti DRIVE BU'd 3Z Nu suite m 103 f t Floor Tenant Name: KREE1- - V4CANT Property Owners Name: RRE E F mailing Address: 631 ST12PttDtR BL STE G CONTACT PERSON Name: P6 CQELL 1 Day Telephone: 206- 361 ^0071 MaaingAddress: R 0• Safe 33370 SEA-ME WA 9g/33 E-Mail Address: 47 0 1 1 0 / 1 4 9 - 57 F M O C H / W i a l L _ Ni ) FaxNumber 206 3 6 1- 0 4 2 - GE ] iERAL CONTRACTOR INFORMATION (Mechanical Contractor information on back page) Company Name: Mailing Address: Contractor Registration Number. "An original or notarized AR : t CT OF RECORD —All plans mast be wet stamped by Architect of Record ENGINEER OF RECORD —All puns mu wet stamped by E -.,. r of Record Company Name: Mailing Addresz Conrad Person: E-Mail Address Reamed: 6805 ta `art CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 einge?peolt+ - . —(7-a04) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted though the mail or by fax. "Please Print" Age 1 714104A ha New Tenant: ' WA- 91 © Yes City Day Telephone: Fax Num Day T Fax Number. Unit Type: Qty Unit Type: Qty Unit Type: Qtv IliK /Cem Qty Fmnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU I Fumace>100KBIU Evaporator Cooler Diffuser 3-15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15-30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventlation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ IIP /1,750,000 BTU Repair or Addition to HeaRefig/Coofing System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator - Comm/1nd Other Mechanical Equipment MECHANICAL PERMIT INFORMATION — 206.431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: PRO - STAFF M� CHANICRL INC, 5Farn- Contact Pawn: PET CQF LLF? Day Telephone: E-Mail Addaxes: (7 GTE ItQF%LD -Sf tFFMECHANI -Cb IA Fax Number Mailing Address: PO go)( 3 33 70 19/571N4 41- Ton/ At tinny (AC-32- 10 34 - ) -TUN At UNIT- 3 W 7e133 sore zW 2o6 -361 Oo-7I 2,06 -361 -o Contractor Registration Number PR05 / 0 72 Al 6 Expiration Date: 6 - 7,0 - 08 "An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance" Valuation of Project (contractor's bid pric $ '7 j 6oV . 00 Scope of Work (please provide detaiedinformation): 4 4 /lc - Fyn -LI CmaNaz -Out gniACE W it l+ A- New T12ANS Me Use: Residential: New_.❑ Replacement Commercial: New .... ❑ Replacement... Fuel Tvpe: Electric_...❑ Gas._a Other. Inrtirate type of mechanical work being installed and the quantity below: BUILDING O OR A r r' r • !ZED AGENT: Sigvanae: Print SPr 1 /� L Print mailing Address: PO Rol, 3VA 7o I Date Application Accepted: rfI I'k( an®• r.f=a.w- verst..o+embon (7-2004) PASS cam r Page 4 PERMIT APPLICATTON NOTES — Applicable to all permits in this application Value of C don - In all taws, • value of construction amount should be entered by the applicant This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 1E0 days following the date of application shall expire by f®dfion. The Bulling Official may grant one or more extensions oftime Sr additional periods uotexceedmg 90 days each The extension shall be requested in writing and justifiable cause demonstnited. Section 10532 International Bail&ng Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY t LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: R /)o/06 Day Telephone: 206 - 3 6 I -Dan StrA -tFt._ 1.4 LPG I33 np Date AppivamoaEtcprrex „ / (1-Iv1- City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2523049071 Permit Number: M06 -180 Address: 1034 INDUSTRY DR TUKW Status: PENDING Suite No: Applied Date: 08117/2006 Applicant: RREEF, BUILDING 32 Issue Date: Receipt No.: R06 -01285 Payment Amount: 246.53 Initials: JEM Payment Date: 0811712006 12:20 PM User ID: 1165 Balance: 50.00 Payee: PRO -STAFF MECHANICAL, INC. TRANSACTION LIST: Type Method Description Amount RECEIPT Payment Check 9771 246.53 ACCOUNT ITEM LIST: Description Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES Account Code 000/322.100 203.22 000/345.830 43.31 Total: 246.53 8733 08/17 9716 TOTAL 246.53 doc: Receipt - Printed: 08 -17 -2006 Proj{ect: /s £f r ez/. /d 32 Type of Inspection: V c.,va i Address: /031/ ___T Jv, Date Called: Special Instructions: Date Wanted: �d: /2-20 m. Requester: Phone No: o? o G - 383 - c 37 required prior to approval. Approved per applicable codes Corrections CO MINTS: J Pa /7 h - r,� - rablea # R P M . f 6,,,,p /die spector. '� ,N4/ aAi �� M..a� Date: ^ q Z Z 0 'U b INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ 8. REINSPECTION FEE ItEQUIRED.rior to inspection, fee must be aid t 6300 Southcenter Bl d., Suite 00. Call to sechedule reinspection. Date: Rec i No.: File: M06- /B0 35mm Drawing #1-' Packaged Cooling Gas /Electric Rooftops PrecedentTM 3 -10 Tons — 60 Hz April 2006 B LPt 3 ) O 3 =.w, ''sr tzy NEW REn- ActMr_►ir tit IIr" P kaged Cooling (T *C) i Packaged Gas /Electric (Y *C) Mae --IV nl►RT PRCO25- EN AUG 17 2006 PIFiMfTCENTER TRANS' Table 1. General Data — 3-4 Tons 16 General Data RT- PRCO25 -EN 3 Tons 4 Tons T /YSCO36A3,4,W T /YSC048A3,4,W Cooling Performance0) Gross Cooling Capacity SEER( Nominal CFM / ARI Rated CFM ARI Net Cooling Capacity Integrated Part Load Value(t) System Power (kW) 37,400 10.7 1,200/1,200 36,000 — 3.79 49,200 10.0 1,600 /1,600 47,000 — 5.40 Compressor Number/Type 1 /Hermetic 1 /Scroll Sound Outdoor Sound Rating (dB)pv) 83 82 Outdoor Coll type Tube Size (in.) Face Area (sq. ft.) Rows /FPI Lanced 0.3125 7.19 2/17 Lanced 0.3125 9.59 1/17 Indoor Coll Type Tube Size (In.) Face Area (sq. ft.) Rows /FPI Refrigerant Control Drain Connection Number /Size (In.) Lanced 0.3125 5.67 2/16 Short Orifice 1 NPT Lanced 0.3125 6.17 3/16 Short Orifice 13'. NPT Outdoor Fan Type Number Used /Diameter (In.) Drive Type /No. Speeds CFM Number Motors/HP Motor RPM Propeller 1/22 Direct/1 2,550 1/0.20 1,075 Propeller 1/22 Direct/1 3,610 1/033 1,075 Direct Drive Indoor Fan Type Number Used /Diameter (In.) Drive Type /Number Speeds Number Motors Motor HP (Standard /Oversized) Motor RPM( (Standard /Oversized) Motor Frame Size (Standard /Oversized) FC Centrifugal 1 /10x10 Direct/2 1 0.33/0.50 930/1,100 48/48 FC Centrifugal 1 /11x11 Direct/2 1 0.60/0.80 1,000 /1,100 48/48 Belt Drive Indoor Pan Type Number Used /Diameter (In.) Drive Type /Number Speeds Number Motors Motor HP (Standard /Oversized) Motor RPM (Standard /Oversized) Motor Frame Size (Standard /Oversized) FC Centrifugal 1 /ttxlt BeIt/Variable Sheave 1 1.00/— 1,750/— 56/— — 1/11x11 — 1 1.00/ — 1,750/ — 56/— Filters(vi) Type Furnished Number Size Recommendediva) Throwaway (2) 20x25x1 Throwaway (2) 20x25x1 Refrigerant Charge Ivlli) Pounds of R -22 3.8 3.8 TRANS' Table 1. General Data — 3-4 Tons 16 General Data RT- PRCO25 -EN TRANE Table 1. (continued) General Data — 3-4 Tons RT-PRCO25 -EN General Data (I) Cooling Performance Is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not Include the effect of fan motor heat. ARI capacity Is net and Includes the effect of fan motor heat. Units are suitable for operation to *20% of nominal cfm. Units are certified In accordance with the Unitary Air-Conditioner Equipment certification program, which Is based on ARI Standard 210/240 except AK (380V/60 Hz). (a) EER and /or SEER are rated at ARI conditions and In accordance with DOE test procedures. 0 Integrated Part Load Value Is rated In accordance with ARI Standard 210/240 or 360. Units are rated at 80 F ambient, 80° F entering dry bulb, and 67° F entering wet bulb at ARI rated cfm. (Iv) Outdoor Sound Rating shown Is tested in accordance with ARI Standard 270. For additional Infor- mation refer to Table 105. (•) T/YSCO36A,3,4,W motor RPM shown Is low speed. High speed RPM Is 1,060/1,145. (N) Optional 2' pleated Alters also available. (w) 20 x 25 filter on medium and low heat models. 20 x 30 filter on high heat models. (w0 Refrigerant charge Is an approximate value. For a more precise value, see unit nameplate and ser- vice Instructions. (o') Heating Performance limit settings and rating data were established and approved under labora- tory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Applicable to Gas /Electric units only. (x) AFUE Is rated In accordance with DOE test procedures. (3,4 Tons Standard Efficiency) 17 3 Tons 4 Tons Heating Performance(") (Gas /Electric Only) Heating Input Low Heat Input (Btu) 60,000 *lid Heat Input (Btu) 80,000 80,00 High Heat Input (Btu) 120,000 4 , Heating Output Low Heat Input (Btu) 48,000 48,000 `Mid Heat Input (Btu) 64,000 64,000 High Heat Input (Btu) 96,000 96,000 AFUE %(x) Low Heat Input (Btu) 81 81 •4id Heat Input (Btu) 81 81 High Heat Input (Btu) 81 81 Steady State Efficiency% Low Heat Input (Btu) 81 81 °Mid Heat Input (Btu) 81 81 High Heat input (Btu) 81 81 No. Burners Low Heat Input (Btu) 2 2 'Mid Heat Input (Btu) 2 2 High Heat Input (Btu) 3 3 No. Stages Low Heat Input (Btu) 1 1 'Mid Heat Input (Btu) 1 1 High Heat Input (Btu) 1 1 Gas Supply Line Pressure Natural (minimum /maximum) 4.5/14.0 4.5/14.0 LP (minimum /maximum) 10.0/14.0 10.0/14.0 Gas Connection Pipe Size (In.) Low Heat 1/2 1/2 .Mid Heat 1/2 1/2 High Heat 1/2 1/2 TRANE Table 1. (continued) General Data — 3-4 Tons RT-PRCO25 -EN General Data (I) Cooling Performance Is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not Include the effect of fan motor heat. ARI capacity Is net and Includes the effect of fan motor heat. Units are suitable for operation to *20% of nominal cfm. Units are certified In accordance with the Unitary Air-Conditioner Equipment certification program, which Is based on ARI Standard 210/240 except AK (380V/60 Hz). (a) EER and /or SEER are rated at ARI conditions and In accordance with DOE test procedures. 0 Integrated Part Load Value Is rated In accordance with ARI Standard 210/240 or 360. Units are rated at 80 F ambient, 80° F entering dry bulb, and 67° F entering wet bulb at ARI rated cfm. (Iv) Outdoor Sound Rating shown Is tested in accordance with ARI Standard 270. For additional Infor- mation refer to Table 105. (•) T/YSCO36A,3,4,W motor RPM shown Is low speed. High speed RPM Is 1,060/1,145. (N) Optional 2' pleated Alters also available. (w) 20 x 25 filter on medium and low heat models. 20 x 30 filter on high heat models. (w0 Refrigerant charge Is an approximate value. For a more precise value, see unit nameplate and ser- vice Instructions. (o') Heating Performance limit settings and rating data were established and approved under labora- tory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Applicable to Gas /Electric units only. (x) AFUE Is rated In accordance with DOE test procedures. (3,4 Tons Standard Efficiency) 17 3 T/YSCO36A3 187 -253 17.9 25 T/YSCO36A4 414 -506 9.2 15 T/YSCO36AW 517 -633 7.7 15 C048A 187 -253 23.9 35 T/Y9C048A4 414 -506 12.8 20 T/YSC048AW 517 -633 9.8 15 TRANS' 5 T/Y5C060A3 187 -253 31.5 50 T/YSC060A4 414 -506 16.0 25 T /YSC060AW 517 -633 12.2 15 T/YSC060AK 342 -418 19.6 30 Electrical Data Table 113. Unit Wiring with Gas Heat or Cooling (No Electric Heat) Standard Indoor Fan Motor 20.3 10.4 8.3 Oversize Indoor Fan Motor Optional Belt Drive Indoor Fan Motorl0 Maximum Fuse Maximum Fuse Maximum Fuse Unit Model Unit Operating Minimum Circuit Size or Maximum Minimum Circuit Size or Maximum Minimum Circuit Size or Maximum Tons Number Voltage Range Ampaclty Circuit Breakertll> Ampaclty Circuit Breaker Ampaclty Circuit Breaker 26.0 40 14.4 2 10.6 15 30 20.6 15 10.6 15 8.3 30 15 15 25.3 35 13.6 20 10.0 15 33.2 50 30.3 45 16.3 25 15.6 - 25 12.8 20 11.8 15 6 T/YSC072A3 187 -253 32.7 50 34.0 50 - - 1/Y5C072A4 414 -506 17.6 25 18.2 25 - - T/YSC072AW 517 -633 12.8 20 13.6 20 - - T(YSC072AK 342 -418 23.2 35 - - - - 71/2 T/YSC090A3 187 -253 42.7 60 45.8 60 - - T/YSC090A4 414 -506 22.6 35 24.1 35 - - T/YSC090AW 517 -633 17,6 25 18.8 25 - - T/YSC090AK 342 -418 28.4 40 29.9 45 - - T/YSC092A3 187 -253 38,9 50 42.0 50 - - T/VSC092A4 414 -506 20.5 25 22.0 25 - - T/YSC092AW 517 -633 15.5 20 16.7 20 - - 81 T/YSC102A3 187 -253 45.1 60 48.2 60 - - T/YSC102A4 414 -506 24.0 30 25.5 35 - - T/YSC102AW 517 -633 19,5 25 20.7 25 - - T/YSC102AK 342 -418 32.6 40 35.6 45 - - 10 T/YSC120A3 187 -253 52,6 60 56.6 70 - - T/YSC120A4 414 -506 26.9 35 28.9 35 - - T/YSC120AW 517 -633 21.8 25 23.5 30 - - T/YSC120AK 342 -418 32.6 40 35.6 45 - - (I) For standard and oversized motors, HACR breaker per NEC. ml optional Belt Drive motor applies to 3-5 ton models only. The Standard Motor for 3 -5 ton models Is Direct olive. The Standard Motor for 6 -10 ton models Is Belt Drive. RT- PRCO25 -EN 91 TRANS' 102 meow*" *00181 ACCESS RUM ECM Mon DatAle SON OEM W 14 NET DEMME R SECTION MEM ALTERNATE CONDEM NT 01 DE NI •14 NET EA HOLE 1N LIT 11/11 Figure 3. Coolin N WPM@ °meama Dimensional Data 1Q N AYL sz oi. AND OOMPASSIOR TOP rum CONDENSER MN DONDENSER 00• VR CONTROL ME NE WWI OA HOU SISM E NNW PORT ACCESS 1 W OWE NOME UNIT POWER WIRE r@MAE IMMDLa Figure 2. tow -and Medium Heat * All dimensions are In Inchesfmillimeters. * *1/2 NPT Gas Connection - (Y_C Models only); 2" Electrical Connection: Single Point Power When Heat Installed (T_C Models only.) Gas /Electric Models • 3 -5 Tons Standard Efficiency TOE PANEL CONDENSER MN CONDENSER COIL UNIT CaTIOL WIRE NC WINO DK HOLE SERVICE GAUGE PORT ACCESS SIT P8 Wr& r tIMI DON= Efficiency High s ons are In Inches /mlllImeters. * *1/2 NPT Gas Connections (Y_C Models only); 2" Electrical Connection: Single Point Power When Heat Installed (T_C Models only.) RT-PRCO25 -EN TRANS' RT- PRCO25 -EN Dimensional Data 691 MM THROUGH THROUGH INC BASE GAS THE BASE ELELIRICAL IY MODELS ONLYI UM Figure 4. Cooling with Optional Electric Heat and Gas /Electric Models 3 -5 Tons - Downflow Airflow Supply /Retum - Through the Base Utilities • All dimensions are In Inches /millimeters. (1739 MM CLEARANCE MP 11916 MMI W4.14 NIT O•MmmmcnON CLEARANCE 99' (640 MM) (Standard and High Efficiency) CLEARANCE a HORIZONTAL FLOW - 19' (457 MM) OOWNFLOW M' 1614 MIA) Figu r .. Cooling with Optional Electric Heat and Gas /Electric Models ons - Horizontal Airflow Supply /Retum dlmenslons are In Inches /millimeters. \TYPICAL ROOF OPENING 39- / (MO MM) 44 11? - 11130 MMI lit CLEARANCE 36' (914 MM) Figure 6. Cooling with Optional Electric Heat and Gas /Electric Models 3 - Tons - Unit Clearance and Roof Opening • All dlmenslons are In inches/millimeters. 103 • MANE' Tab l - 8. Maximum Unit & Corner Weights (Lbs) and Center of Gravity Dimensions (in.) Cooling with Optional Electric Heat Units on Tons Mo. o. Shipping Net A B C D Lengt Width 501 409 132 104 79 94 19 518 426 139 108 84 95 32 19 434 140 110 91 33 19 560 468 146 113 97 111 31 20 5 TSC060A 543 - 149 114 - 99 31 18 THCO6DA 610 518 165 124 105 124 31 19 6 TSC072A 824 681 - 119 150 38 21 THC072A 861 718 235 182 128 173 38 22 71 TSC090A 897 754 2 129 180 37 22 TSC092A 899 756 61 20 131 162 39 21 THC092A 1000 857 289 222 148 197 38 21 81 TSC102A 978 281 223 181 40 21 THC102A - 1036 893 294 233 159 207 39 22 10 TSC120A r 880 298 238 158 :7 40 21 THC120A 125 982 323 253 178 2 39 22 3 TSCO3 THCO36A 4 TSC048A THC048A 0) Weights are ap. ate. (s) Weights do i c ude additional Factory or Field Installed options /accessories. For option /accessory additional weights, refere . b le 130 to be added to unit I Co. eights are given for Information only. C1HTEa or GRAVITY WIDTH A .--- L[NOTH Table 129. Maximum Unit and Comer Weights (Lbs) and Center of Gravity Dimensions (In.) Gas /Electric Units only Unit Model Basic Model Weights (Lbs)( ),00 Corner Weights (lbs)( 11 0 Tons Number Shipping Net 3 YSCO36A Basic Model Weights , Corner Weights 572 Weights A B C D Center of G Center of Gravity (In.) Length Width 480 151 124 96 109 32 19 159 130 108 109 33 19 169 134 105 114 32 18 735 249 193 132 161 39 21 772 249 198 141 184 39 22 820 273 208 146 193 38 22 822 277 222 147 175 40 21 923 306 243 165 210 39 22 899 297 243 165 194 40 21 957 310 252 175 220 40 22 958 317 261 177 202 41 21 1060 342 277 197 245 40 22 YSC060A 614 6 YSC072A THC072A 71 YSC090A 963 YSC092A 965 THC092A 1066 81/2 YSC102A 1042 THC102A 1100 10 YSC120A 1063 YHC120A 1203 (I) Weights are approximate. 00 Same as above. (I11) Comer weights are given for Information only. 110 878 915 RT-PRCO25 -EN • • TRANE° Weights • Table 130. Factory Installed Options (FIOPS) /Accesso t Weights (Lbs) Net Weight Accessory 3 -5 Tons 6 -10 Tons Barometric Relief �7 10 Belt Drive Motor 38 — Coll Guards 12 20 Dehumidification (Hot Gas Reheat) Coll 15 25 Economizer 26 36 Electric Heaterstslt 15 Hinged Doors 10 12 Motorized Outside Air Damper 20 30 Manual Outside Air Damper 16 26 Novar Control 8 8 Oversized Motor 0 8 Powered Convenience Outlet 38 38 Powered Exhaust — 80 Roof Curb 70 115 Smoke Detector, Return 7 7 Smoke Detector, Supply 5 5 Stainless Steel Heat Exchanger(] 4 6 Through the Base Electrical 8 13 Through the Base Gas 5 5 Unit Mounted Circuit Breaker 5 5 Unit Mounted Disconnect 5 1p Weights for options not listed are <5 lbs. 00 Net weight should be added to unit weight when order) 0s) Applicable to Cooling with Electric Heat Units only. 0 Applicable to Gas /Electric Units only, N- fa o in led accessories. RT•PRCO25 -EN 111 C � 2 ID34' ExI - sIwr� I on Vl4 T d'k. )..4e,�,_ 4rx, kn ".r. iymo, ..di5ra J.k,� ;fit,m rt�,,l40,,,,,, ! 1 ✓. .: i gn.,l'.lt .- v'- r;l- w,.'Iik.,- eggffg OPTIONAL • ROB POWER SAVER BASIC-— - a < NIT • .v4 • CHA8- 651.653 (With optional POWER SAVERT•M• , electric heat and roof mounting frame) Three Air Patterns Possible Basic unit is horizontal with end delivery of conditioned air. Use of optional RTB duct enclosu e or RDB POWER SAVER allows bottom handling of conditioned air. L� Downdlo (Extended duct distribution system) RT8 or RD8 required Installation Flexibility Featured In Single package concept and optional roof mounting frame are Lennox exclusive features and give Lennox rooftop equipment a big edge over competition both in appearance and installation procedures. Primarily designed for in- stallation on a rooftop with the optional RT8 duct en- closure or RD8 POWER SAVERt.M•, it can also be installed on a slab at grade level with end handling of conditioned air. The single package unit contains all refrigeration com- ponents (evaporator and condenser units) air movers, air filters, and optional electrical heat in one complete package. The optional RT8 or RD8 duct enclosure and SINGLE PACKAGE AIR CONDITIONER CHAS- 511 -513 AND CHAS- 651 -653 HORIZONTAL AND DOWN -FLO *49,000 to 59,000 Btuh Total Cooling Capacity 21,000 to 112,500 Btuh Optional Electric Heat *API Certified Ratings OPTIONAL ROOF MOUNTING FRAME Horizontal (Basic unit) NOTE — Specifications, ratings and dimensions subject to change without notice, EPL4 um 12 t;)t/ttiiiit}^.i.1 ENGIN II COOL, P P P DATA g01 NOINITS KA age 1) Febn ' 1970 Super +,1 - 16 - 69 Optional Roof Mounting Frame Detail Weatherproof frame (RMF3-65) is used whenever RTB duct enclosure or RDB POWER SAVER T.M. is used. The frame extends around the entire perimeter of the CHA8 and RT8 or RD8. Duct connection and entry into the conditioned area are accomplished within the confines of the frame. Down -flo (Combination ceiling supply and return) RT8 or RD8 required Single Package Alr Conditioning Unit RMF3 mounting frame easily adapt to the CHA8 unit. The mounting frame mates to the bottom of the CHA8 and duct enclosure and when flashed into the roof per- mits weatherproof duct connection and entry to the conditioned area. No additional roof curbing or flashing is required —the RMF3 frame does the entire job. Option- al POWER SAVER and controls (RD8) reduce cooling costa and satisfy any local code fresh air requirements. Externally mounted optional minimum fresh air damper (manual) is also available. Choice of 230V single phase or 208V thru 550V three phase models is available. Model No. 1 1 CHA8- 511 -513 C CH H - .. ,.,. .. ..: Outdoor Air rem a ure Entering Condenser (F) ) .... , . „ • p- , Evapo ator Air 85 95 105 116 80F Dy Bulb Entering Total Total Sensible Comp. Total Sensible Comp. Total Sensible Comp, Total Sensible Comp. Bulb Alt Cooling To Total Motor Cooling To Total Motor Cooling To Total Motor Cooling To Total Motor Volume Capacity Redo Input Capacity Ratio Input Capacity Ratio Input Capacity Ratio Input Oegreat (Cfm) IBtuh) (S/T) Watts (Stull) (S/T) Watts (Btuh) (S/T) Watts (Btuh) IS /T) Watts (F) 1600 51,200 .87 5430 46,800 .91 5690 43,000 .94 6100 38,900 .97 6430 63 1800 52,700 .88 5510 48,700 .92 5820 44,800 .96 6230 40,400 .99 6560 2000 54,000 .89 5590 - 49,800 .94 6890 46,000 .98 6320 41,500 1.00 6650 1600 -300 .69 5600 50,200 - .73 5920 46,100 .78 6330 41,600 .84 6650 67 1800 65,500 .72 5670 51,300 .76 5990 47,200 .79 6420 42,500 .85 6750 2000 56,600 .76 6730 52,300 .79 6060 48,000 .82 6480 43,500 .86 6820 1600 67,800 .54 6800 64,000 .56 "6170 50,500 .67 6660 46,500 .59 7080 71 1800 68,900 .65 6860 55,100 .57 6250 51,500 .69 6740 47,500 .61 7160. 2000 59,800 .56 5910 56.400 .59 6330 52,800 .61 " 6830 48,400 .63 7240 2000 58,500 .85 6570 55,000 .88 6950 49,800 .92 7240 44,200 .96 7670 63 2250 60,300 .87 6670 57,200 .90 7080 52,000 .94 7380 46,500 .98 7830 2500 61,700 .90 6740 58,700 .92 7170 64,100 .96 7520 48,800 1.00 8000 =, 2000 61,800 .71 6750 59,100 .73 7190 54,200 ,75 7520 48,900 .78 8000 67 2250 63,500 .72 8830 60,800 .74 7290 56,100 .77 7660 61,100 .79 8170 ; - 2500 64,700 .73 6900 62,200 .75 7370 57,700 ,78 7760 52,800 .81 8300 •' 2000 64,800 .53 6900 62,200 .54 7370 57,600 .56 7760 52,800 .57 8300 71 2250 66,100 .56 6970 63,500 ,56 7450 59,200 .57 7860 54,300 .58 8410 2500 67,300 .56 7040 64,900 .67 7530 61,000 .58 7980 56,200 .60 8520 I 199 8Qdb/67W(1 eptry/Ing avePorator air YtCleanable pgliurathane filter 'Nq4 Vaaiq'ht ' , 't Figsh diffuser with adlgateblo baffle blades SPECIFICA OHS •; RATINGS -` -103 1 Y , F9Yec pent outdoor elr. fempe rpture an d ACTIVITY NUMBER: M06 - 180 PROJECT NAME: RREEF, BUILDING 32 SITE ADDRESS: 1034 INDUSTRY DR DATE: 08 -17 -06 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: A efri Building Division m Public Works C DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Comments: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2-28-02 QERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 0IA- o$llM9 Fire Prevention AL Structural Incomplete ❑ TUES/THURS ROUTING: Please Route ❑ Structural Review Required REVIEWER'S INITIALS: DATE: DATE: Planning Division ❑ Permit Coordinator No further Review Required DUE DATE: 081-22-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 09 -19 -06 Approved with Conditions ❑ Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License PROSTMI072NG Licensee Name PRO STAFF MECHANICAL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601038859 Ind. Ins. Account Id 52073600 Business Type CORPORATION Address 1 PO BOX 33370 Address 2 City SEATTLE County KING State WA Zip 98133 Phone 2063610071 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/7/1993 Expiration Date 6/30/2008 Suspend Date Separation Date Parent Company Previous License PROSTHA136NJ Next License Associated License Business Owner Information Name Role Effective Date Expiration Date ALMO, LEONARD L PRESIDENT 08/07/1993 Bond Amount ALMO, PENNY VICE PRESIDENT 08/07/1993 103645389 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #7 TRAVELERS CAS & SURETY CO 103645389 08/07/2001 Until Cancelled $12,000.00 07/30/2001 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https : / /fortress.wa.gov /lni/bbip/ printer .aspx?License= PROSTMI072NG 08/24/2006 TAG . MODEL # SIZE CFM MIN OSA COOLING (BTUH) COOLING SEER HEATING INPUT HEATING OUTPUT AFUE ELECTRICAL (3 phase) WEIGHT (LBS.) AC - 32 - 1034 TRANS Y8C048A3RMA 4-Ton Ton 1,500 ` 200 39,200 10.0 80,000 65,000 81% 208 230/$/60 MCA = 27.2 FUSE = 40 543 !Building #32 Building #34 ROOF PLAN AC -32 -1034: Replace the existing 4 -Ton AC unit with a new 4 -Ton AC unit. Permit No. Plan review approval Is Subject to errors and Approval of construction documents does not the violation of any accepi:ed code Of ord na •� . of approved Field Copy end conditions is D , City of Tukwila Phase 111 r81vd. 1NKt_G2 1 1 r: . • 11111 l� I� 1•1'a 11. 1 1 1 1 t h: 1111 :1:111:, 111 Phase IV REVISIONS • OF UKWIIA Job # 1149 AU . 17 2006 PERMITCENTER SHEET NUMBER M "Like -for- Like" EQUIPMENT REPLACENE EXISTING CONSTRUCTION EOUIPMENT NOTES: 1. Economizer and barometric relief air damper. 2. New 7 -day programmable thermostat. 3. New gas piping from a new gas meter. 4. Outside air intake to be 10' -0" from exhaust outlet, gas flues & plumbing vents. 5. Existing Unit being replaced: Lennox Model #CHA8 -511, Weight = 770 pounds. SCOPE OF WORK: "LIKE- FOR - LIKE" change -out. Replace existing 4 -Ton AC unit AC -32- 1034 with a new Trane 4 -Ton AC unit. u: . II I IIUIIIII IL IIIIt I lIIJI jI:J I.Llilu Strander Blvd. 11111111 , III� ►I llllilij�lIIIIljiliil:lil liliTi� ..il,.iilir : coon v16 • a 2 , w .3 ,...._. ,.. 4 .... .......... 5 6 v e ` : , l• o IIiIJt1IIIIIIII�1IIIIt ?I11. ;Ii liaillili:��II1I1III1III G OFFICE er Blvd. A, G