Loading...
HomeMy WebLinkAboutPermit M06-187 - REHABITAT NORTHWESTREHABITAT NW 13330 32 AV S EXPIRED M06 -187 Parcel No.: 1523049101 Address* 13330 32 AV S TUKW Suite No: City W Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: cttukwila.wa.us Tenant: Name: REHABITAT NORTHWEST INC. Address' 13330 32 AV S, TUKWILA WA Owner: Name: MALINAK DOLORES Address' 13330 32ND AVE S, SEATTLE WA MECHANICAL PERMIT Contact Person: Name: OLIVER PROCK Address: 3601 WEST MARGINAL WY SW, SEATTLE WA Contractor: Name: CASTLE HEATING & A/C INC Address: PO BOX 620, SOUTH PRAIRIE WA Contractor License No: CASTLHA055DH Permit Number: Issue Date: Permit Expires On: DESCRIPTION OF WORK: REPLACE EXISTING FORCED AIR FURNACE WITH NEW CARRIER, STA 0990 -16, 80 %. Value of Mechanical: $750.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall /Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC- Permit EQUIPMENT TYPE AND QUANTITY 1 0 0 0 0 0 0 0 0 0 0 0 0 0 **continued on next page** MO6 -187 biesi Phone: Phone: 206 931 -9891 Phone: Expiration Date:02 /05/2008 Steven M. Mullet, Mayor Steve Lancaster, Director M06 -187 08/22/2006 02/18/2007 Fees Collected: $127.34 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU 30-50 HP/1,750,000 BTU 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 08 -22 -2006 Permit Center Authorized Signature I hereby certify that I have read and City bw Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Fax: 206431 -3665 Web site: cttukwila.wa.us ll II t x•mi ed ,„Jtk ordinances governing this work will b: om with, whether specified herein or not. doc: IMC- Permit Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -187 Issue Date: 08/22/2006 Permit Expires On: 02/18/2007 Date: Inl hi0 his permit and know the same to be true and correct. All provisions of law and The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: ( --_ Date: SI2216Co Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M06 -187 Printed: 08-22-2006 Parcel No.: 1523049101 Permit Number M06 -187 Address: 13330 32 AV S TUKW Status: ISSUED Suite No: Applied Date: 08/22/2006 Tenant: REHABITAT NORTHWEST INC. Issue Date: 08/22/2006 1: ***BUILDING DEPARTMENT CONDITIONS*** 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. doc: Conditions CITY Olt Tlq. ,I A DEPT CF. CC:11C: I 63C3 S' U " ti f.;.::J I L , ; ; .. D. TUKWILA, WA PERMIT CONDITIONS "continued on next page** PERMIT CENTS 1 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248 - 6630). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. M06 -187 Printed: 08 -22 -2006 CITY OF TUK` V' A DEPT. OF CO` ,:,a i, fY Cw`.. `. C C:..NT 6300 SC,UTFIC.L.NILiu1LL''O TUKWILA, WA 9■733 I hereby certify that I have read these conditions and will comply with them governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or regulating construction or the performance of work. Signature: (Th b — C)LwU Print Name: doc: Conditions PERMIT CENTER as outlined. All provisions of law and ordinances cancel the provision of any other work or local laws Date: $1221A M06 -187 Printed: 08 -22 -2006 CITY OF TUKWILA Community Developmenpartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. c i. t ukwila. wa. us SITE LOCATION Site Address: 1 5330 ,320b (-V1'E S Tenant Name: Property Owners Name: ?--0 ft ry 4I J 1 N C- Mailing Address: 73 („n \ 1/J, Yuck?.. 41 V`3pt& WY -SW S��'SCTI_ I ywk G8loC, Cit 'CONTACT PER80 who do we contact when your permit is ready to be Issued Name: CD sti I Mailing Address: SkMt= E -Mail Address: Company Name: Ch31 LE 1 Ekt Mailing Address 'P O .x G to MECHANICAL PERMIT APPLICATION Contact Person: W iJ E -Mail Address: Contractor Registration Number: (' A C L*4 A O 5 51)+1 Q:Uppllutiooflonnn- Applications On Line\ -2066 - Mechanical Permit Application.doe Revised: 4-2006 as Mechanical Project No or office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print ** King Co Assessor's Tax No.: IG2. - 1 D 1 Suite Number: Day Telephone: LO 6 3 R -9211 City Fax Number: New Tenant: S ?'t1R -1E wA 983$6 City State Day Telephone: 15 3 211 Fax Number: Floor: .... Yes State Zip State State Zip ROHS ..No Zip MECHANICAL CONTRACTOR INFORMATION Expiration Date: ARCHITECT O F RECORD - All plans must b y - Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Zap Page I of 2 Unit Type: ° ' Qty - Unit Type: Qty ,Unit Type: Qty Boiler /Compressor:. Qty Furnace<100K BTU 1. Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator— Comm/Ind Other Mechanical Equipment Valuation of Project (contractor's bid price): $ 1 CO Scope of Work (please provide detailed information):_2 'LACE CPt Use: Residential: New .... ❑ Replacement .... R Commercial: New .... 0 Replacement ....0 Fuel Type: Electric 0 Gas.... Other: Indicate type of mechanical work being installed and the quantity below: nnoDEL_ ��lE� 3i T - 0 go -lb to gat Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: R 2-1 ( Oro Day Telephone: Mailing Address: 92 )C n 1 W Cl A1Za ( NAM-- WOO SYN SCE l -iLE- W R - n 7' Ibco Cit BUILDING OWNER OR AU ZED AGENT: Signature:_( k - -� Print Name: t \ tl t £ I Date Application Accepted: Q1Application, Fanner- Applications On Line \3 -2006 - Mechanical Permit Application doe Revised. 4-2006 bh t Isl f= ¶off A4 696 -16 :01, State Zip Date Application Expires: Staff Initials: Page 2 of 2 RECEIPT NO: R06 -01312 Initials: JEM User ID: 1165 Payee: REHABITAT NORTHWEST, INC. SET TRANSACTIONS: Set Member Amount 4406 -187 PG06 -126 TOTAL: ACCOUNT ITEM LIST: Description MECHANICAL - RES PLUMBING - RES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 SET ID: S000000543 SET NAME: Tmp set/Initialized Activities 127.34 88.00 215.34 SET RECEIPT Payment Date: 08/22/2006 Total Payment: 215.34 TRANSACTION LIST: Type Method Descript Amount Payment Check 5938 215.34 TOTAL: 215.34 Account Code Current Pmts 000/322.100 127.34 000/322.100 88.00 TOTAL: 215.34 8913 08122 9710 TOTAL 215.34 Steven M. Mullet. Mayor Steve Lancaster, Director Turn to the Experts Willis Carrier invented air conditioning in 1902. Over 100 years later, we're proud to say Carrier systems are trusted In more homes than any other brand. Carrier continues to be on the forefront of Innovative engineering and unsurpassed standards of excellence. So when choosing a home comfort system, you'll want to turn to the experts. Your Carrier dealer will evaluate your home, such as window placement and size, ductwork, other structural specifics and lifestyle to provide a customized Indoor comfort plan designed specifically for you. And when you have an expert helping you make an educated decision, you're going to feel more comfortable. Turn to the Experts' www.carrler.com 1- 800 - CARRIER A member of the United Technologies Corporation feenily. Stock Symbol VOL c Caller Corporation 2004 868-436 IW14e0ea manes le Vito decants whinge aary are, erecfalaa Cr reevewithout Ste a aeu/ tang aeopwva IMPRINT AREA -NO VARNISH G ,a EN ER GUIDE rtiva.r.ra. m` at% tier an 01-02 -2007 OLIVER.PROCK 3601 WEST MARGINAL WY SW SEATTLE WA 98106 RE: Permit No. M06 -187 13330 32 AV S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Buiilling Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be In writing and :Provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 02/18/2007 , your permit will become null and void and any further work on the project will.require a new permit and associated fees. Thank you for your cooperation in this matter. xc: Permit File No. M06-1 87 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director • • 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206- 431 -3665