Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M06-198 - BOEING #9-98
BOEING #9 -98 9725 EAST MARGINAL WAY S M06 -198 Parcel No.: Address: Suite No: Owner: Name: Address: Contact Person: Name: Address: doc: IMC- Permit City W Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: cttukwila.wa.us 0003400018 9725 EAST MARGINAL WY S TUKW Tenant: Name: BOEING #9 -98 Address: 9725 EAST MARGINAL WY S, TUKWILA WA THE BOEING COMPANY PO BOX 3703 M/S #1F -09, SEATTLE WA STEVE FLINK - MACDONALD MILLER PO BOX 47983, SEATTLE WA Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983, SEATTLE, WA Contractor License No: MACDOFS980RU Value of Mechanical: 034,675.00 Type of Fire Protection: MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: DESCRIPTION OF WORK: COMPLETE MECHANICAL RENOVATION OF TWO -STORY OFFICE BUILDING. REPLACE (4) AIR HANDLERS WITH CHILLED WATER AND STEAM COILS. DUAL DUCT SYSTEM WITH VAV'S. TYPICAL BATHROOM EXHAUST SYSTEM FOR (4) BATHROOMS. Fumace: <100K BTU >100K BTU Floor Furnace Suspended/Wall /Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial /Industrial EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 4 4 0 3 0 0 0 0 "continued on next page** M06 -198 Phone: Phone: 206 396 -8657 Phone: 206- 763 -9400 Expiration Date: 12/31/2006 Steven M. Mullet, Mayor Steve Lancaster, Director M06 -198 10/04/2006 04/02/2007 Fees Collected: $20,469.13 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU 30 -50 HP/1,750,000 BTU 50+ HP/1,750,000 BTU 0 Fire Damper 1 Diffuser 675 Thermostat 137 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 10 -04 -2006 Permit Center Authorized Signature: /A/1 Vl Signature: Print Name: doc: IMC- Permit City Or" Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Fax: 206431 -3665 Web site: ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -198 Issue Date: 10/04/2006 Permit Expires On: 04/02/2007 Date: 101 1.1-1 1( 6 1 hereby certify that 1 have read and in d t is permit and know the same to be true and correct. All provisions of law and ordinances goveming this work will b mp with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction he performary:e of work. I am authorized to sign and obtain this mechanical permit. Date: 4 044 c kvc F /;nA This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M06 -198 Printed: 10- 04-2006 Parcel No.: 0003400018 Address 9725 EAST MARGINAL WY S TUKW Suite No: Tenant: BOEING #9 -98 1: ***BUILDING DEPARTMENT CONDITIONS * ** 4: Readily accessible access to roof mounted equipment is required. 12: ** *FIRE DEPARTMENT CONDITIONS*** doc: Conditions City thsTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Fax: 206431 -3665 Web site: et.tukwila.wa.us PERMIT CONDITIONS Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number M06 -198 Status: ISSUED Applied Date: 09/13/2006 Issue Date: 10/04/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) M06 -198 Printed: 10-04 -2006 doc: Conditions City &Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206431 -3665 Web site: ci.tukwila.wa.us **continued on next page" Steven M. Mullet, Mayor Steve Lancaster, Director 15: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 16: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 17: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 18: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 19: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 20: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 21: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 22: An electrical permit from the Washington State Department of Labor and Industries is required for this project. 23: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 24: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25' These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. M06 -198 Punted: 10-04-2006 City de Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Conditions Stasi Sieve. F n i& Date: /o/V/00 M06 -198 Printed: 10-04 -2006 Var CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.cltukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print** SITE LOCATION Ai �"" Mai Way n King Co Assessor's Tax No.: U Site Address: 9725 Gaa/ Flai oied WAy c�ptaM 11/(1? Suite Number: Floor: Tenant Name: aft n el �( n ' I New Tenant: ❑ Yes ;CND Property Owners Name: Meiit� Iii �t( rer'Gk /SS 1! S cGvt Mailing Address: 92,9A- Yom! t� P/a Uf M / . / WA1 hsili / 4489 921n �./ / City State Zip CONTACT PERSON Name: c 17CVPr Plink - Mac Qtna 101 - M ier � Day Telephone: (2060 3% -n57 Mailing Address: PO Box N7983 cJ Arne WA 98/e/6 ( Ciry State Zip E -Mail Address: 8 }eVe thk € Mat, loin ICY !?OM Fax Number: (zoc Re- V2R7 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) ) Company Name: Mailing Address: City Contact Person: Day Telephone: E - Mail Address: Fax Number: Expiration Date: Contractor Registration Number. ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number. ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q` pica iwskFonus aPaSaa ws On IiaeU -3006 - Pumit Appl'medan.dac Revised: 43006 M Building Permit No. Mechanical Permit No. A/LCt2 1 Plumbing/Gas Permit No. Pfraf - H Public Works Permit No. Project No. (For office use only) Sue State State Zip Zip Page 1 of Unit Type: Qty_ Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<10OK BTU Air Handling Unit >10,000 CFM Fire Damper l 0 -3 HP /100,000 BTU Fumace>IOOK BTU Evaporator Cooler Diffuser (0l' 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat /37 15 -30 HP /1,000,000 BTU - Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /I,750,000 BTU Repair or Addition to Heat/Refriy/Cooling System 1 I Incinerator - Domestic Emergency Generator Air Handling Unit <10,000CFM �/ 7 Incinerator — ComnJlnd Other Mechanical Equipment 42 (l„de � s . p '[fi k •sat MECHANICAL PERMIT INFORMATION — 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company : Mac Dona ld- Miller ritcile ci/u//ont Mailing Address: . t 0. Fox 97 983 Contact Person: C\ ` eve- F An k E -Mail Address: tC .v e.• '1" 1 f h k @ MAC N1; tom Contractor Registration Number MAC PO FS 9SO Ru se: Residential: New .... Replacement New....❑ Replacement...,® / Fuel Type: Electric CZ Gas ....❑ Other: cS t C�r 11¢01 tatier Indicate type of mechanical work being installed and the quantity below: p nppliwoes`rorm•MW+wiwa Linen -2006 • hank Application/Mx Revised: 4-2016 bb c e a /e WA 98/n/!0 City State Zip Day Telephone: 000340 '8(eS7 Fax Number: (2010 7408'V287 Expiration Date: / /311010 Valuation of Project (contractor's bid price): $ 3 03 7S. 00 scope of Work (please provide detailed information): (that'll / r&ndYa- Of-Pee LIkl;nn�� Replaces. e l A ;rhanx� /e,-s OA Milled t)a er Coils and cc aan Col • Dua dolt- SyB G/iill V*Vi. "Ty pits / La Aron. Qxlt4w4f 31ST - `/ l room, Par 4 of Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) g 8 Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain /6 Sinks S Dental unit, cuspidor Shower, single head trap 2, Urinals 12. Dishwasher, domestic, with independent drain Lavatory zy Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) 12- Water heater and/or vent Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Additional medical gas inlets/outlets — six or more 5Ainthff gild LJ �7 - PLUMBING AND GAS PIPING PERMIT INFORMATION — 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Matbotnmtld- Mfli,Gr- FacJk.j Sokkovrc Mailing Address: Po. Box N7983 $eaft City Contact Person: cSTevE f Ithk E -Mail Address: &eve R k Q mac Nt r fief . PA»t Contractor Registration Number P 98o Rte awpi io treaaa- Appt On Una..206• /Wait App+K aeratdd 44406 bh Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quan ity below: State Zip Day Telephone: (2a0) 396 46.5 7 Fax Number: (20 7(of -1/2-1r7 Expiration Date: / /d1a Valuation of Project (contractor's bid price): $ 7 8 { � 2.8. 00 )) p Qp Scope of Work (please provide detailed information): 8141 id Y &tout4 bn Ot 7 L 1✓0 .S #Ovy O/f't L btu;Id; • Wask /Amer 'tics into e4s�,N. a,�'l,l;es. raw &//rina .nc, Waller .r ev- ^Slew :r •, tJa 4J4_ Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. }3t ildi • and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHOO AGENT: Signature: E Sit �fLL �-41 'I M Date: 9 //3/0(0 Print Name: ti vee. FEY/ k - MAC bo►'r, �cl - Matti Telephone: ( 3%' g(o,S7 Mailing Address: n 80 X LI79R3 ScaH WA 9819(o cit I Date Application Accepted: 01 ( + Q:Nppliemima Po ns- Appnr+noaa On LinU-2006 - Permit Ap$iaado dae Reviled: 41006 M Date Application Expires: State Zip Staff Initials: Page 6 orb City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0003400018 Permit Number: M06 -198 Address' 9725 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 09/13/2006 Applicant: BOEING #9 -98 Issue Date: Receipt No.: R06 -01563 Payment Amount: 20,469.13 Initials: JEM Payment Date: 10/04/2006 01:12 PM User ID: 1165 Balance' 50.00 Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. TRANSACTION LIST: Type Method Description Amount RECEIPT Payment Check 1034 20,469.13 ACCOUNT ITEM LIST: Description Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES Account Code 000/322.100 16,381.30 000/345.830 4,087.83 Total: 20,469.13 0404 10/05 9710 TOTAL 20469.13 doc: Receipt Printed: 10-04-2006 Project: ir Type of Inspection: Address: y7 At- Date Calle' - Special Instru ons: / _ /CN ((7 i 7397-(2) Date Wanted: � a.m m. . 3-13 .Q Cr11) Requester: - 3 - „ - ,, ny Phone No: J zCZ ' rAr1 7 Si' .? INSPECTIOiI. Inspector: INSPECTION RECORD Retain a copy with permit Date: PE CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 206)431 -3670 rrections required prior to approval. ri $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Project: ed '✓6 5 -)- 5 t Type of Ins ection: /I /.j Address: 72 5 t o ii7A2, ,, V a / Date Called: eeeee T Ap*'t $ /? tivl(S .3 S - Special Instructions: Date Wanted: a.m. Requester: Phone No: 04 -73d - 255 y Approved per applicable codes. Jj Corrections required prior to approval. COMMENTS: p .. 0 J 4,9 4 -,c' oo- ,..,p le- -r eeeee T Ap*'t $ /? tivl(S .3 S - spec &IAA? )'lt .4 4WrM9 Date: 2 -2 3_07 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 58.00 REINSPECTIONIEE REQUIRF Prior to inspection, fee must be aid at 6300 Southcent r Blvd., Su a 100. Call to sechedule reinspection. Receipt No.: Date: Project: Project: 5 Type of Ins ection: ...07,4" "C )-, Address: Date ailed: Special Instructions: Date Wanted: ? ,� f /� V' ..m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPEOTION NO. CITY OF TUKWILA BUILDING DIVISION PERMIT 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: la s /- � — / -i 91- .17 %( 4-7 -1-7 /3/e#7/ / / /J] / / //'l /J! 42 7/Z 0 $58.00 0 $58.00 REINSPECTION ItE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: /1 Project: ///��� /J /&) ..v, S . S Type of Inspection: d 'I'4v✓# 1 ' v A ress: /7 5 Pis rr���Gs ate CBNed: . Special Instructions: Date Wanted: /- .7/ - U -7 Clip.. P.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 Approved per applicable codes. COMMENTS: C/ Se ?ter in/ fir/ lM /e/c/ t7 4AUV rr ,'7r /N rAvs /a /4/1/ Q , Ite. -wrf L 1 S LOr: i e' ' Date: .00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be id at 6300 Southcenter DI d., Suite 100. Call to sechedule reinspection. (Receipt No.: (Date: ter s Corrections required prior to approval. Project: p(31rin/rS 9-5� T of Inspection: � z,prFr / a �or�/YOs Address: 9 7? 5 P P14001v/.!/ Date Caile Special Instructions: Date Wanted: / -2 —O7 (Sm:. P.m. Requester: Phone No: -9,e7 6 -230 - Z "5 t/ INSPEOrION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. R %) L Li \ m /Ai 71 -S /140✓i COMMENTS: nspecyor: /act ( J 5 00 REINSPECTION FEE EQUIRED Prior to inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. INSPECTION RECORD Retain a copy with permit !Receipt No.: !Date: (206)43 -36 /2) O 6 /5 e PERM Date: / — Z "7 NO. Projecx /` /5ot/Nce `7 -ge Type of Inspection: - izaty 11 - / Ytl V Address: 9725 &s4 yNA1iAm Date Iled: Special Instructions: Date Wanted: / — / - U7 Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: e i L ti,if P W s-- o L ro C&FQ ecto ceipt No.: INSPECTION RECORD Retain a copy with permit 'Date: PE ( 06)431 -36 El Approved per applicable codes. ❑ Corrections required prior to approval. 7 - 07 JS8.00 REINSPECTION FF REQUIRED Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Project: /25Of /NI 7 -5, Type of Inspection: ,?di /y h - ,-- �/ V Address: ?7.25 C /r1A2C.n04/ Date Called: Special Instructions: Date Wanted: X02 - G- OC • a.m. Requester: Phone No: INSPECTION NO. El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 20. )431 -3 El Corrections required prior to approval. COMMENTS: , � 4 _% ,VS1ic,9 .f t r/ %✓��✓ 4,o-i1 n/7. Inspect • : Date: 2 -G —D $ .00 REINSPECTION FEE EQUI . Prior to inspection, fee must be aid at 6300 Southcenter al d., Suite 100. Call to sechedule reinspection. Re¢f!ipt No.: !Date: COMMENTS: / J 1, Floe e . 1-/-142 NT10 - 1 '4 /9/ 6 ^ ✓ 1 1 A 1 1 t C . Y i S + % I n/ L1 i t t1 n/ PC (/ get t r 'n^t'l - ,14 ► - 0 e r(sttVc),/G.rfc ifpa 4 beni(J )ntr A/ fDS t5Le / ar )2 ewtev,d z ,t/ ria y rvl -J& t1 � P..Ks�v 1 L1 4 r4 c / �tMyr - 4 7 A � , � s 14 iir- a Requester: Phone No r-,2o‘ 92 3 -5570 Project: - Type o Inspection: 60,94 Address: 9 r Ts-1 17175,h4/ Date Calle : Special Instructions: Date Wanted: .//— 8 a G la;irr �frrtT Requester: Phone No r-,2o‘ 92 3 -5570 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- 0 Approved per applicable codes. Inspector: !Date: El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. (Receipt No.: INSPECTION RECORD Retain a copy with permit 0 Corrections required prior to approval. Date: Proje _ '—% Type of Inspectio : 7 /�� \J Ad ss: Date Ca led: Sp I Instructions: J v t!.,9 co 1 Date Wanted: /��' / - ) ( ■ v � p ' m . Requester: D In Phone No: INSPECTION NO. El Approved per applicable codes. iteillallaidaglaaaaaat INSPECTION RECORD Retain a copy with permit PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)4 670 Corrections required prior to approval. COMMENTS: a A s AL:( . If, ea4 mita .41 .sta• $58.0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: 'Date: Pro' ct: f3oF /n/b 9 - 9� Type of Ins ction: Neo,h- At Address: 9 7a5 P40///7 Date Called: ' Special Instructions: /Si T /oo C Date Wanted: /Q -/7 O G a.m. P .m. , Requester: Phone No: - Qoa- q?_ 3 -,55 7,, • INSPECTION RECORD Retain a copy with permit INSPECT! N NO. "•. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. PERMIT NO. (206)431 -367 Corrections required prior to approval. R4 1 COMMENTS: 1 0fl,/ un-..../ s i: I — 7/ , fir, � CZ** /2. / / c gise �J / /ee !t/7 t aly%-n- ! n $58.00 R INSPECTION FtE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: 'Date: MAYES TESTING ENGINEERS, INC. February 28, 2007 City of Tukwila Building Department 6200 South Center Blvd Tukwila, WA 98188 -8188 Attn.: Building Official Re: Boeing Seattle Bldg 9 -98 Renovation Development Center Tukwila, WA MTE Project No. E6421 Gentlemen, Special inspection was provided for: Reinforced Concrete Soils Compaction Epoxy Anchors and Dowels Structural Steel Erection (Welding and Bolting) Sincerely, MAYES TESTING ENGINEERS, INC. Timothy G. ckerle, P.E. Branch Manager cc: Gayle White — Boeing Commercial Airplane Group Greg Abell — Boeing Commercial Airplane Group Greg Farrar — Boeing Commercial Airplane Group FINAL LETTER Permit #-Mci6 -498 Everett Office 917 -134th Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503 281 7515 fax 503.281.7579 This is to inform you that registered special inspections have been completed for this project as per our reports, copies of which have been sent to you. To the best of our knowledge, all work inspected was either performed in accordance with, or corrected to conform to, the city approved drawings, or engineer approved changes. We trust that this provides you with the information which you require. Should you have any questions give us a call. MAYES TESTING ENGINEERS, INC 1111111=11111111:=w2:172, , MTE No.: Project: Address: Permit No.: Bldg Dept.: Owner: Architect: Engineer: Contractor: Page 13 Date: Weather: Inspection: Sample(s): REVIEWED BY: E6421 BOEING SEATTLE BLDG 9 -98 RENOVATION Development Center, Tukwila, WA M06 -198 City of Tukwila Boeing Commercial Airplane Group Lease Crutcher Lewis 3/30/07 Clear - -- Project Management N/A cc: Greg Abell, Greg Farrar — Boeing Commercial Airplane Group Rec eiver) MAY 0 9 2001, COI Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 251584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 Project management during the month of March including coordination of personnel and report review for compliance with project documents. Preparation of final letter of compliance INSPECTOR: Tim Beckerle E- MAILED APR 30 2007 Lynnwood Office 20225 Cedar Valley Road Suite 110 Lynnwood, WA 98036 ph 425.742.9360 fax 425.745.1737 MAYES TESTING ENGINEERS, INC. ,.- ..,.. .. • MTE No.: Project: Address: Permit No. Bldg Dept. Owner: Architect: Engineer. Contractor: Page 12 Date: Weather: Inspection: Sample(s): REVIEWED BY: E6421 BOEING SEATTLE BLDG 9 -98 RENOVATION Development Center, Tukwila, WA M06 -198 City of Tukwila Boeing Commercial Airplane Group Lease Crutcher Lewis 2/28/07 Clear Project Management N/A thy G. Beckerle, P.E. cc: Greg Abell, Greg Farrar - Boeing Commercial Airplane Group RECEIVED k''N 1 2 2001 Everett Office 917 -134th Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 tax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584,3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 Project management during the month of February including coordination of personnel and report review for compliance with project documents. Preparation of final letter of compliance. INSPECTOR: Tim Beckerle E- MAILED MAR 282007 MAYES TESTING ENGINEERS, INC. MTE No.: Project: Address: Permit No. Bldg Dept. Owner: Architect: Engineer: Contractor: Page 10 Date: Weather: Inspection: Sample(s): E6421 BOEING SEATTLE BLDG 9 -98 RENOVATION Development Center, Tukwila, WA M06 -198 City of Tukwila Boeing Commercial Airplane Group Lease Crutcher Lewis 2/15107 (indoors) Epoxy N/A REVIEWED BY: / 4,�..�— ,'Tim b y G. Beckerle, P.E. cc: Greg Abell, Greg Farrar— Boeing Commercial Airplane Group RECEIVED MAR 13 2001 Deffson COMMU wir INSPECTOR: Tom Cain Everett Office 917.13411, Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Port /and Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 Inspected installation of epoxied bolts at new channels along three stairway landings (2nd floor) per RFI 047 SK -A1. Installation was according to this detail with Hilti HIT -ICE epoxy into well - cleaned holes. Embedment was predominantly 6" min. with some embedded 4 -5 ", which was Okayed by MKA via email. To the best of our knowledge, items inspected this date are in accordance with approved plans and specifications. E- MAILED FEB 191001 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 lax 253.584.3707 MAYES TESTING ENGINEERS, INC. MTE No.: Project: Address: Permit No. Bldg Dept. Owner: Architect: Engineer: Contractor: Page 11 Date: Weather: Inspection: Sample(s): REVIEWED BY• E6421 BOEING SEATTLE BLDG 9 -98 RENOVATION Development Center, Tukwila, WA M06 -198 City of Tukwila Boeing Commercial Airplane Group Lease Crutcher Lewis 2/19/07 Cloudy /Rain Structural Steel N/A W G. Beckerle, P.E. cc: Greg Abell, -reg Farrar— Boeing Commercial Airplane Group RECEIVED MAR 13 2007 COMMUNITY DEVELOPMENT INSPECTOR: Tom Cain E- MAILED MAR 0 2 2007 Everett Office 917 -134th Street SW Suite A•1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E•2 Tacoma, WA 98499 ph 253 584 3720 tax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 tax 503.281.7579 At operable wall /partition beams at 1st, 2nd and 3rd floors, contractor has added an angle brace parallel to beam, bracing off existing support beam — this per conversation with MKA — installation was inspected and acceptable. This closes out previous nonconformance report regarding operable wall /partition beam. To the best of our knowledge, items inspected this date are in accordance with approved plans and specifications. MAYES TESTING ENGINEERS, INC Project Name: Site Address: Client: Engineer: Contractor: Air Temperature: Weather: Product: Supplier: Ticket Number : MixDesign ID : Sample Temp. (ASTM C1064) Water /Cement Ratio: Y Date Made Sample # 1 01/10/07 1 1 01/10/07 1 01/10/07 1 1 01/10/07 Remarks: 61 °F 0.484 1 0004 1 1 0004 1 0004 1 1 0004 Boeing Seattle Bldg 9 -98 Renovation Development Center Tukwila, WA Boeing Commercial Airplane Group Lease Crutcher Lewis 43 °F Cloudy Concrete Glacier Northwest 894932 3210 1 0926 1 0927 I Initial Storage Temp. (ASTM C31) 0928 0929 1 CONCRETE LABORATORY TEST REPORT NR Slump (ASTM C143) 6" [Placement Location and Notes: Set 1 Slab -on -grade at East building entry. 1 01/17/07 1 02/07/07 1 02/07/07 1 1 02/07/07 1 17 1 28 1 28 28 Inspector(s): Cain, T. Tested by. Johnson, S. J. FIELD DATA ASTM C31 and C172 Entrained Air I (ASTM C231) 6.2% L Sample(s) Rec'd: 01/11/07 COMPRESSION TEST RESULTS (ASTM C39, C1231, and C617 when applicable) Lab # Date Tested Age Size (In) Load (Ibs) Dia (in) 1 4x8 4x8 4x8 1 1 4x8 1 Design 44360 1 1 59280' 1 1 59790 58250 1 Mix Proportions: Ingredient NE Admix Cement —Type I & II Coarse Aggregate 3/4" Fine Aggregate Water Required Strength: (fc) 3000 psi @ 28 days 1 4.00 1 4.00 1 4.01 1 1 4.00 1 E- MAILED FEB 0 91007 Project No: E6421 Issued on: 02/08/07 Sample Set ID: 31442 Permit # (s): M06 -198 Original: ° RECEIVED Revised: fl Surface Strength (psi) 1 12.57 1 12.57 1 12.63 1 1 12.57 1 Reviewed by: 1 3530 4720 1 4730 1 1 4640 1 NOTES: Break descriptions for samples tested with neoprene pads are not required per ASTM Std. All testing performed In accordance with applicable ASTM's except C-31, 10.1.2 - "recording field temperature' Intonation in this report applies otdy to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers. Inc. Everett 917 -134th Street SW Suite A -1 Everett WA 98204 ph 425.742.9360 tax 425.745.1737 FEB 1 6 2C COMMUNITY DEVELOPMENT Weight (per cu.yd) 4.0 517.0 1,930.0 1,300.0 250.0 oz Ibs Ibs Ibs Ibs Break Type NA NA NA NA imothy G. Beckerte, P.E. Branch Manager X IflE 1050.IC, Rev 2.10 MAYES TESTING ENGINEERS, INC. MTE No.: Project: Address: Permit No. Bldg Dept. Owner: Architect: Engineer: Contractor. Page 8 Date: Weather: Inspection: Sample(s): E6421 BOEING SEATTLE BLDG 9 -98 RENOVATION Development Center, Tukwila, WA M06 -198 City of Tukwila Boeing Commercial Airplane Group Lease Crutcher Lewis 1110/07 Cloudy Structural Steel N/A NONCONFORMING CONDITIONS REVIEWED BY: / t hy G. Beckerle, A.E. cc: Greg Abell, Greg Farrar— Boeing Commercial Airplane Group RECEIVED [JAN 2 6 2007 COMMUNITY DEVELOPMENT Everett Orrice 917 -134th Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 Inspected erection, welding, and bolting for two operable wall support beams and entry canopy at east side of building. Found work according to plan, except: (1) at operable wall beams contractor has substituted a single angle or plate for double angles shown at typical supports (3 locations per beam), ref. detail D /S5.05 — add #1; (2) contractor has not installed single brace in line with beam per partial plan 5/S110— add #1 (also at operable partition beams). INSPECTOR: Tom Cain E- MAILED A..�11 2:81 MAYES TESTING ENGINEERS, INC. MTE No.: Project: Address: Permit No. Bldg Dept. Owner: Architect: Engineer: Contractor: Page 9 Date: Weather: Inspection: Sample(s): E6421 BOEING SEATTLE BLDG 9 -98 RENOVATION Development Center, Tukwila, WA M06 -198 City of Tukwila Boeing Commercial Airplane Group Lease Crutcher Lewis 1/10/07 Cloudy Concrete (4) 4x8" cylinders Contractor placed approx. 20 cubic yards of Glacier mix #3210 into slab -on -grade at east building entry. Sampled first truck and cast (4) 4x8" test cylinders at 6" slump and 6.2% entrained air. To the best of our knowledge, items inspected this date are in accordance with approved plans and specifications. REVIEWED BY: / � Lt N / Timothy G. Beckerle, P.E. cc: Greg Abell, Greg Farrar — Boeing Commercial Airplane Group INSPECTOR: Tom Cain 1 Everett Office 917 -134th Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253 584 3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503 281 7579 MAYES TESTING ENGINEERS, INC Project Name: Site Address: Client: Engineer: Contractor: Air Temperature: Weather: Product: Supplier: Ticket Number : MixDesign ID : Sample Temp. I (ASTM C1064) `Water/Cement Ratio: Date Made Sample # 01/10/07 01/10/07 01/10/07 01/10/07 Remarks: 61 °F 0.484 0004 0004 0004 1 0004 1 MiS 3162251 = q— 71'" Boeing Seattle Bldg 9 -98 Renovation Development Center Tukwila, WA Boeing Commercial Airplane Group Lease Crutcher Lewis 43 °F Cloudy Concrete Glacier Northwest 894932 3210 0926 0927 Initial Storage Temp. (ASTM C31) 0928 1 0929 CONCRETE LABORATORY TEST REPORT NR Slump (ASTM C143)1 6" [Placement Location and Notes: 11 Set 1 Slab -on -grade at East building entry. COMPRESSION TEST RESULTS (ASTM C39, C1231, and C617 when applicable) Lab # Date Tested Age Size (in) Load (Ibs) Dia (in) 01/17/07 02/07/07 02/07/07 1 02/07/07 Inspector(s): Cain, T. Tested by Revilla, Z. Entrained Air (ASTM C231) 7 28 1281 28 FIELD DATA ASTM C31 and C172 6.2% Sample(s)Recd: 01/11/07 1 4x8 4x8 1 4x8 I 4x8 Design 1 44360 1 E-M AILED 1A1119 7 4.00 1 0.00 1 0.00 0.00 1 Everett 917 - 134th Street SW Suite A -1 Everett WA 98204 ph 425.742.9360 fax 425.745.1737 Project No: E6421 Issued on: 01/18/07 Sample Set ID: 31442 Permit # (s): M06 -198 Original: Q Revised: Mix Proportions: Ingredient NE Admix Cement - -Type I & II Coarse Aggregate 3/4" Fine Aggregate Water Required Strength: (f'c) 3000 psi @ 28 days Surface Strength (psi) 12.57 0.00 1 1 0.00 0.00 3530 NOTES: Break descriptions for samples tested with neoprene pads are not required per ASTM Std. All testing performed in accordance with applicable ASTM's except C -31, 10.1.2 - "recording field temperature" Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc. Weight (per cu.yd) 4.0 517.0 1,930.0 1,300.0 250.0 oz Ibs Ibs Ibs Ibs Break Type NA 1' IThTIA NA NA Reviewed by: Ti othy G. Beckerle, P.E. / Ti Branch Manager MTE 1050-1C. Rev 2. 10/18/ MAYES TESTING ENGINEERS, INC.RECENED 130 08 E6421 COMMUNIT MTE No.: Project: BOEING SEATTLE BLDG 9 -98 RENOVATION,EVEEO Address: Permit No.: Bldg Dept.: Owner: Architect: Engineer: Contractor: Page 7 Date: Weather: Inspection: Sample(s): 11/28/06 Cylinder pick -up Picked up cylinders at job site, and delivered to MTE Everett lab. Preliminary Inspection Development Center, Tukwila, WA M06 -198 City of Tukwila Boeing Commercial Airplane Group Lease Crutcher Lewis REVIEWED BY: cc: Greg AbelKGreg Farrar— Boeing Commercial Airplane Group thy G. Beckerle, P.E. INSPECTOR: Tom Cain E MAILED DEC 0 5 2006 Everett Office 917 -134th Street SW Suite A -1 Everett, WA 98204 ph 425.7429360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 MA ■ ES TESTING ENGINEERS, INC Project Name: Site Address* Client: Engineer: Contractor: Air Temperature: Weather: Product: Supplier: Ticket Number : MixDesign ID : Sample Temp. I (ASTM C1064) Water/Cement Ratio: Date Made Sample # Lab # 196611 1 19862 1 11/14/06 1 Remarks: 11/14/06 1 11/14/06 11/14/06 60 °F 0.502 1 0003 0003 0003 1 0003 1 Boeing Seattle Bldg 9 -98 Renovation Development Center Tukwila, WA Boeing Commercial Airplane Group Lease Crutcher Lewis 42 °F Clear Concrete Glacier Northwest 878543 3350 Initial Storage Temp. (ASTM C31) ti `Slump (ASTM C143) 1 1 19663 1 19664 1 CONCRETE LABORATORY TEST REPORT NR 4 -3/4" [Placement Location and Notes: II Set 1 New roof curbs for mechanical units. COMPRESSION TEST RESULTS (ASTM C39, C1231, and C617 when applicable) Date Tested Age Size (in) Load (Ibs) Dia (in) 1 11/29/06 1 12/12/06 12/12/06 1 1 12/12/06 1 Inspector(s): Cain, T. Tested by. VanderPol, A. Entrained Air (ASTM C231) I k Sample(s) Recd: 15 I 1281 1 28 1 128 FIELD DATA ASTM C31 and C172 5.1% 11/15/06 1 4x8 4x8 1 4x8 4x8 1 Design 1 60220 E- MAILED E C 0 41006 1 Mix Proportions: Ingredient Coarse Aggregate 3/8" Fine Aggregate Water Cement —Type I & II NE Admix Required Strength: (f c) 3000 psi @ 28 days 4.01 0.00 0.00 1 1 0.00 1 Project No: E6421 Issued on: 11/30/06 Sample Set ID: 30556 Permit # (s): M06 -198 Original: Revised: 0 Surface Strength (psi) Failure Code 12.63 1 0.00 0.00 1 1 0.00 Reviewed by: 4770 Branch Manager NOTES: Failure descdptions for samples tested with neoprene pads are not required per ASTM Std. All testing performed in accordance with applicable ASTM's except C-31, 10.1.2 - 'recording field temperature" Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers. Inc. Everett 917 - 1341h Street SW Suite A -1 Everett WA 98204 ph 425.742.9360 fax 425.745.1737 Weight (per cu.yd) 1,810.0 Ibs 1,255.0 lbs 283.0 lbs 564.0 lbs 4.0 oz NA NA NA 1 NA 1 y G. Beckerle, P.E. PATE 1050.1C. Rev 2, 10/18/ MAYES TESTING ENGINEERS, INC Project Name: Site Address: Client: Engineer: Contractor. Air Temperature: Weather. Product: Supplier: Ticket Number : MixDesign ID : Sample Temp. I (ASTM C1064) Water /Cement Ratio:` Date Made Sample # Lab # 1 11/14/06 1 1 11/14/06 1 1 11/14/06 1 11/14/06 1 Remarks: 60 °F 0.502 1 0003 1 0003 0003 1 1 0003 1 Boeing Seattle Bldg 9 -98 Renovation Development Center Tukwila, WA Boeing Commercial Airplane Group Lease Crutcher Lewis 42 °F Clear Concrete Glacier Northwest 878543 3350 Initial Storage Temp. (ASTM C31) Slump (ASTM C143) Y 1 19661 1 19662 1 19663 1 19664 1 CONCRETE LABORATORY TEST REPORT NR 4 -3/4" [Placement Location and Notes: Set 1 New roof curbs for mechanical units. 1 11/29/06 1 1 12/12/06 1 1 12/12/06 1 12/12/06 1 Inspector(s): Cain, T. Tested by Revilla, Z. 1 15 1 28 1 28 X281 FIELD DATA ASTM C31 and C172 Entrained Air I (ASTM C231) 5.1% Sample(s) Rec'd: 11/15/06 COMPRESSION TEST RESULTS (ASTM C39, C1231, and C617 when applicable) Date Tested Age Size (In) Load (Ibs) Dia (in) 4x8 4x8 4x8 4x8 1 Design 1 60220 1 66080 66600 1 63450 1 E- MAILED CLC 19 205 1 Mix Proportions Ingredient Coarse Aggregate 3/8" Fine Aggregate Water Cement —Type I & 11 A/E Admix Required Strength: (fc) 3000 psl @ 28 days 4.01 1 4.00 1 4.00 4.02 1 Reviewed by Project No: Issued on: Sample Set ID: Everett 917 - 134th Street SW Suite A -1 Everett WA 98204 ph 425.742.9360 fax 425.745.1737 E6421 12/13/06 30556 Permit # (s): M06 -198 Original: Revised: Weight (per cu.yd) 1,810.0 lbs 1,255.0 lbs 283.0 Ibs 564.0 Ibs 4.0 oz Surface Strength (psl) Break Type 1 12.63 1 1 12.57 1 12.57 1 1 12.69 1 1 4770 1 5260 1 5300 5000 1 NOTES: Break descriptions for samples tested with neoprene pads are not required per ASTM Std. All testing performed in accordance with applicable ASTM's except C-31, 10.1.2 - 'recording field temperature' Information In this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc. NA NA NA 1 NA 4 4€4 Q.{J err l • Timothy G. Beckerle, P.E. Branch Manager ° ARE 1050 -1G, Rev 2. 10/181 MAYES TESTING ENGINEERS, INC. MTE No.: Project: Address: Permit No.: Bldg Dept.: Owner: Architect: Engineer: Contractor: Page 4 Date: Weather: Inspection: Sample(s): REVIEWED BY: 11/13/06 Indoors Epoxy N/A E6421 BOEING SEATTLE BLDG 9 -98 RENOVATION Development Center, Tukwila, WA M06 -198 City of Tukwila Boeing Commercial Airplane Group Lease Crutcher Lewis by G. Beckerle, P.E. cc: Greg Abell, (Greg Farrar — Boeing Commercial Airplane Group RECEWE 'DEC ' 0 5 2006 z aOP+ur INSPECTOR: Mark McBride E- MAILED NOV 171006 Everett Office 917 -134th Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253 584 3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 Observed the installation of #4 "U" bands into the roof level slab at the east and west penthouses for curbs for new AHU units per detail C /S505. Holes were cleaned with brush and compressed air prior to installing dowels using Powers Fast Plus Adhesive by Powers Fasteners. Existing curbs at both penthouses are being utilized. Straight pieces of #4 bars were installed adjacent to and horizontally into the existing curbs. To the best of our knowledge, items inspected this date are in accordance with approved plans and specifications. MAYES TESTING ENGINEERS, INC. MTE No.: Project: Address: Permit No. Bldg Dept. Owner: Architect: Engineer: Contractor: Page 5 Date: Weather: Inspection: Sample(s): REVIEWED BY: E6421 BOEING SEATTLE BLDG 9 -98 RENOVATION Development Center, Tukwila, WA M06 -198 City of Tukwila Boeing Commercial Airplane Group Lease Crutcher Lewis 11/14/06 Clear Concrete (4) 4x8" cylinders Final rebar inspection and acceptance for new roof level mechanical unit curbs. Contractor pumped approximately 5 cubic yards of Glacier mix #3305 into curbs. Sampled concrete and cast (4) 4x8" test cylinders at 4 -3/4" slump. Also, contractor placed slab replacement and storefront curb. Dowels were epoxied into slab edge with 4 -1/2" embedment prior to pouring. To the best of our knowledge, items inspected this date are in accordance with approved plans and specifications. y G. Beckerle, P.E. cc: Greg Abell, Greg Farrar — Boeing Commercial Airplane Group INSPECTOR: Tom Cain E- MAILED NOV 172006 Everett Office 917 -1341h Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503281 7515 fax 503.281.7579 MAYES TESTING ENGINEERS, INC. MTE No.: Project: Address: Permit No. Bldg Dept. Owner: Architect: Engineer: Contractor: Page 6 Date: Weather: Inspection: Sample(s): E6421 BOEING SEATTLE BLDG 9 -98 RENOVATION Development Center, Tukwila, WA M06 -198 City of Tukwila Boeing Commercial Airplane Group Lease Crutcher Lewis 10/13/06 Clear Project management (1) soil sample for Proctor Visited site to review project requirements with Marc Schwarz, LCL. Obtained 1 sample of native soil excavated from utility trench for laboratory analysis. Reviewed curtain wall testing requirements with envelope testing sub - consultant, Mike Henry, QED. REVIEWED BY: Timothy G. Beckerle, P.E. cc: Greg Abele Greg Farrar Boeing Commercial Airplane Group INSPECTOR: Tim Beckerle E NOV 22P006 Everett Office 917 -134th Street SW Suite A -1 Everett. WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 fax 253 584 3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 MAYES TESTING ENGINEERS, INC Project Name: Site Address: Client: Engineer: Contractor: Air Temperature: Weather: Product: Supplier: Ticket Number : MixDesign ID : Sample Temp. I (ASTM C1064) Water /Cement Ratio: [Placement Location and Notes: Date Made Sample # Lab # 10/24/06 10/24/06 1 10/24/06 1 10/24/06 1 Remarks: 71 °F 0.502 1 0001 0001 1 0001 1 1 0001 1 Boeing Seattle Bldg 9 -98 Renovation Development Center Tukwila, WA Boeing Commercial Airplane Group Lease Crutcher Lewis 55 °F Rain Concrete Glacier Northwest 854290 3350 Initial Storage Temp. ` (ASTM C31) I Slump (ASTM C143) 1 18070 18071 1 18072 1 1 18073 1 CONCRETE LABORATORY TEST REPORT NR 6" 1 10/31/06 1 11/21/06 1 11/21/06 1 1 11/21/06 1 Inspector(s): Pratt, C. Tested by Revilla, Z. FIELD DATA ASTM C31 and C172 Design Entrained Air (ASTM C231) Sample(s) Rec'd: 7 1 28 1 28 1 28 1 NR 10/25/06 Set 1 Topping slabs on L2, Ef- HJ/9 -11, L1, Ef -HJ 9 -11 along with trenches in slab. Fiber mesh added but no quantity recorded. COMPRESSION TEST RESULTS (ASTM C39, C1231, and C617 when applicable) Date Tested Age Size (in) Load (Ibs) Dia (in) 4x8 4x8 4x8 1 4x8 E- MAILED 1 45770 1 57080 56680 1 56580 1 I Mix Proportions: Ingredient Coarse Aggregate 3/8" Fine Aggregate Water Cement —Type I & 11 A/E Admix Accel r:nr Required Strength: (fc) 4000 psi @ 28 days 4.00 4.00 4.00 1 4.00 1 Project No: E6421 Issued on: 11/22/06 Sample Set ID: 30204 Permit # (s): m o (o-- (g C Original: i] Revised: 0 Surface Strength (psi) Failure Code 12.57 12.57 12.57 1 1 12.57 1 3640 4540 1 4510 1 4500 Reviewed by: . j Timo yG. Beckerle, P.E. ( Branch Manager NOTES: Failure descriptions for samples tested with neoprene pads are not required per ASTM Std. All testing performed in accordance with applicable ASTM's except C -31, 10.1.2 - "recording field temperature Information In this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc. Everett 917 - 134th Street SW Suite A -1 Everett WA 98204 ph 425.742.9360 fax 425.745.1737 Weight (per cu.yd) 1,810.0 Ibs 1,255.0 Ibs 283.0 Ibs 564.0 Ibs 4.0 oz 120.0 oz 1 NA NA NA 1 NA 1 MTE 1050 -1C. Rev 2,10/18/ MAYES TESTING ENGINEERS, INC Project Name: Site Address: Client: Engineer: Contractor: Air Temperature: Weather: Product: Supplier: Ticket Number : MixDesign ID : Sample Temp. I (ASTM C1064) Water /Cement Ratio: Placement Location and Notes: Set 1 70 °F 0.502 Topping slab at L1, Ef- HJ/4.5 -6.5 and L2, Ef- HJ/4.5 -7. Fiber mesh added but no quantity recorded Date Made Sample # 1 10/25/06 1 1 10/25/06 1 10/25/06 1 10/25/06 Remarks: 0002 1 1 0002 0002 1 0002 1 Boeing Seattle Bldg 9 -98 Renovation Development Center Tukwila, WA Boeing Commercial Airplane Group Lease Crutcher Lewis 54 °F Clear Concrete Glacier Northwest 854378 3350 CONCRETE LABORATORY TEST REPORT I Initial Storage Temp. (ASTM C31) NR Slump (ASTM C143) I 5" Entrained Air I (ASTM C231) Sample(s) Rec'd: COMPRESSION TEST RESULTS (ASTM C39, C1231, and C817 when applicable) Lab # Date Tested Age Size (in) Load (Ibs) Dia (in) 18074 18075 18076 1 18077 11/01/06 11/22/06 11/22/06 11/22/06 1 Inspector(s): Pratt, C. Tested by. Veach, B. 171 1 28 28 1 28 1 FIELD DATA ASTM C31 and C172 NR 10/26/06 4x8 1 4x8J 4x8 1 4x8 1 Design E- MAfLE;1 t"" 2 42470 1 65000 64000 64000 Project No: E6421 Issued on: 11/27/06 Sample Set ID: 30205 Permit # (s): /Y) ( — iCjs' Original: Revised: I Mix Proportions: Ingredient Coarse Aggregate 3/8" Fine Aggregate Water Cement - -Type I & II NE Admix Accel Required Strength: (fc) 4000 psi @ 28 days 1 4.00 1 4.01 1 4.01 1 4.02 1 Surface Strength (psi) Failure Code 12.57 12.63 12.63 12.69 1 3380 5150 5070 1 5040 NOTES: Failure descriptions for samples tested with neoprene pads are not required per ASTM Std. All testing performed in accordance with applicable ASTM's except C -31, 10.1.2 - recording field temperature' Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc. Everett 917- 134th Street SW Suite A -1 Everett WA 98204 ph 425.742.9360 fax 425.745.1737 Weight (per cu.yd) 1,810.0 Ibs 1,255.0 Ibs 283.0 Ibs 564.0 Ibs 4.0 oz 120.0 oz NA NA NA NA 1 Reviewed by: � tt4._.tc , Ti. Beckerle, P.E. 7 Branch Manager MTE 1050 -1C, Rev 2, 101181 MAYES TESTING ENGINEERS, INC Project Name: Site Address: Client: Engineer: Contractor: Air Temperature: Weather: Product: Supplier: Ticket Number : MixDesign ID : r Sample Temp. I (ASTM C1064) 70 °F Water /Cement Ratio: 0.502 Placement Location and Notes: Set 1 Date Made 1 10/25/06 1 Pi 0/25106 10/25/06 1 10/25/06 1 Remarks: Sample # 0002 0002 0002 0002 54 °F Clear Concrete Glacier Northwest 854378 3350 18074 f 18075 ] 18076 18077 1 Inspector(s): Pratt, C. Tested by Bastian, N. CONCRETE LABORATORY TEST REPORT Boeing Seattle Bldg 9 -98 Renovation Development Center Tukwila, WA Boeing Commercial Airplane Group Lease Crutcher Lewis - Seattle Initial Storage Temp. (ASTM C31) NR Slump (ASTM C143) I 5" 1 11/01/06 11/22/06 11/22/06 1 11/22/06 FIELD DATA ASTM C31 and C172 Design Entrained Air (ASTM C231) I NR Sample(s) Rec'd: 10/26/06 COMPRESSION TEST RESULTS (ASTM C39, C1231, and C617 when applicable) Lab # Date Tested Age Size (in) Load (Ibs) Dia (in) 7 28 28 L2C 4x8 4x8 - 1r 4x8 4x8 J 42470 E- MAILED NOV 032006 4.00 0.00 0.00 1 0.00 1 Reviewed by: Everett 917 - 134th Street SW Suite A -1 Everett WA 98204 ph 425.742.9360 fax 425.745.1737 Project No: E6421 Issued on: 11/02/06 Sample Set ID: 30205 Permit # (s): Original: Revised: O Mix Proportions: Ingredient Coarse Aggregate 3/8" Fine Aggregate Water Cement - -Type I & II NE Admix Accel Required Strength: (f'c) 4000 psi @ 28 days Topping slab at L1, Ef- HJ/4.5 -6.5 and L2, Ef- HJ/4.5 -7. Fiber mesh added but no quantity recorded. Surface 12.57 1 0.00 J 0.00 1 0.00 1 Strength (psi) Failure Code 3380 Branch Manager NOTES: Failure descriptions for samples tested with neoprene pads are not required per ASTM Std. All testing performed in accordance with applicable ASTM's except C -31, 10.1.2 - - recording field temperature' Information In this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc. Weight (per cu.yd) 1,810.0 Ibs 1,255.0 Ibs 283.0 Ibs 564.0 Ibs 4.0 oz 120.0 oz NA NA NA t' NA — 1' y G. Beckerle, P.E. MTE 1050.1C, Rev 2,101181 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M06 -198 DATE: 09 -13 -06 PROJECT NAME: BOEING SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: RTMENTS: 6u d ng Divis n Public Works ❑ 51,1 - g- - Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2.2802 Incomplete ❑ Approved with Conditions ❑ Permit Coordinator ❑ DUE DATE: 09-14-06 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 10-12-06 Not Approved (attach comments) ❑ DATE: Planning Division Not Applicable ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License MACDOFS980RU Licensee Name MACDONALD/MILLER FAC SOL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602254260 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 PO BOX 47983 Address 2 City SEATTLE County KING State WA Zip 98106 Phone 2067684180 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/31/2002 Expiration Date 12/31/2006 Suspend Date Separation Date Parent Company Previous License DIVCOI•988RC Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SIGMUND, FREDRIC PRESIDENT 12/31/2002 KOPET, TYLER SECRETARY 12/31/2002 KOPET, TYLER TREASURER 12/31/2002 LOVELY, STEVE C VICE PRESIDENT 12/31/2002 Look Up a Contractor, Electrit*in or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must mamtain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress. wa. gov /1ni/bbip /printer.aspx ?License= MACDOFS980RU 10/04/2006 SIM MMID i VICINITY MAP FROM SEATTLE TACOMA AIRPORT DEVELOPMENTAL CENTER MOW WAS: 9-96 REIENK OFFICE MIR 'A' 41801&6 -O2 DaRS` 9-96 RE9oiilc OFFICE IKEA ! DIM OQ PROCNE ESIYI m MOW OFFICE MIMI 9-96 RENOW1oN 418046 --04 410005-00 41409-00 ChM MAIM D. RDD E3 OH\ 1214.96 02.11.99 01.15.06 NO SOU G M L1TA'Y AIRC VLSSHI SYSTEMS AREA MAP sri AMON I 9 - 98 RENOVATION (VOLUME 2 of 2) JOB #140799 --00 BOEING DEVELOPMENTAL CENTER 9725 E. MARGINAL WAY S. TUKWILA, WASHINGTON . 98108 BUILDING ADDRESS: 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 9 -98 BUILDING LOCATION MOM NO WM 1 GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO GARY TALLER AT BUILDING 9 -51.2 COLUMN N /1, AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT CHECKLIST CHECK BOX ET THESE DRAWINGS CONFORM TO THE I.B.C., I.F.C., I.M.C., U.P.C., N.E.C. AND THE WAC 51 -20 AS ADOPTED OR AMENDED BY LOCAL ORDINANCES AND COMPUA NCE WITH CITY OF TUKWILA, WASHINGTON ZONING. IR ROOMS LABELED PER OCCUPANCY PER I.B.C. TABLE 1004.1.2. ® BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. IR NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: O 1. TENANT IMPROVEMENT (STRUCTURAL): O 5 SETS OF ARCHITECTURAL. DRAWINGS O 5 SETS OF STRUCTURAL DRAWINGS O 5 SETS OF STANDARD DETAILS O 5 SETS OF ENGINEERING CALCULATIONS O 5 SETS OF ENERGY CALCULATIONS O 5 SETS OF CONSTRUCTION SPECIFICATIONS IN 2. TENANT IMPROVEMENT (NON— STRUCTURAL): O 4 SETS OF ARCHITECTURAL DRAWINGS O 4 SETS OF STANDARD DETAILS O 4 SETS OF ENERGY CALCULATIONS O 4 SET'S OF CONSTRUCTION SPECIFICATIONS O 3. MECHANICAL, 4 COMPLETE SETS. O 4. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS. BREF PROJECT NARRATNE: COMPLETE RENOVATION OF BOTH FLOORS OF THE 9 -98 BUILDING, UPGRADE OF ALL BLAMING SYSTEMS AND 11TERIOR GLAZING SYSTEM. p rIMMAIII5• • ACCEPTABILITY DIS OE= aN ?APPROVED Itt DINE OWL SEPARATE PERMIT REQUIRED FOR 0 Mechanical ' edrkal liPlumbing O Gas Piping City of ltkwila , _BUILDING DIVISION MUNN iME CALLER WOWED IIMME 12.14.96 MUMS No Changes shall be made to the scope of tort without poor approval of Tukwila Building DWis NOTE: Revisions will require a new plan submittal and may include additional plan review fees. . • ISSUED FOR CONSTRUCTION I SPANME TITLE SHEET ARCHITECTURAL MINSTER 9-98 RENOIOIDON BUILDING 988 DEN. CENTER, WA_ • Nan review Amami of cow does � � the violation cf cny occepied code or ordinance Repot of approved Fie :d 1 y d .. . i acknowladails By Date City of liakwle nozNG DIVISION CODE SUMMARY LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS FIRST FLOOR SECOND FLOOR PENTHOUSE BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE DESIGN LOADS: ROOF — SNOW /UVE FLOOR — OFFlCE (LIVE) FLOOR — DEAD FLOOR — MECHANICAL & STORAGE FLOOR — STAIRS AND CORRIDORS WIND LOADING FIRE EXTINGUISHERS: CITY OF TUKWILA, WASHINGTON 2003 INTERNATIONAL. BUILDING- CODE (IBC) 2003 INTERNATIONAL FIRE CODE -(IFC) 2003 INTERNATIONAL MECHANICAL CODE (IMC) 2005 NATIONAL ELECTRICAL CODE (NEC) 2005 UNIFORM PLUMBING CODE (UPC) 2005 STATE OF WASHINGTON ENERGY CODE STATE OF WASHINGTON BARRIER FREE CODE WITH CITY OF TUKWILA,. WA. AMENDMENTS GROUP B, OFFICE TYPE 11 -6, NON — COMBUSTABLE 67,351 145,382 67,351 67,351 10,680 44 FT. 2 NO CHANGES BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT DESIGN CATEGORY D 25 PSF 50 PSF 20 PSF (PARTITION) 125 PSF 100 PSF 80 MPH, EXPOSURE C Mat-1 TYPE: AMEREX MODEL 461, RATED 3A:408:C, 6 12 CAPACITY. MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER = 75 FEET, MAXIMUM FLOOR AREA PER EXTINGUISHER = 11,250 SF RECEVED CITY OF TI Win t SEP 13 %066 PERMITCENTEH • OM N0. RECEIVED AUG 16 zoos LEWIS-MAIN OFFICE ACV I1S DLR Group a A siga GO 09- 098—GO 08.15.06 i • • • • 3 8 1 EXHAUST FAN (EF) SCHEDULE . NUMBER LOCATION AREA SERVED (ROOM NO.) FAN DIA SIZE ARRNGMT. NUMBER CLASS CFM TOTAL STATIC PRESS. INCHES WG MAX. OUTLET VELOCITY FPM RPM X. S INLET GUIDE VANES BHP MOTOR 1 g w BASIS OF DESIGN SERVICE DATE HP VOLTS PH HZ EF -1 WEST PENTHOUSE WEST BATHROOMS 18 9 I 5,720 0.75 1658 1432 RGHT NO 1.41 1-1/2 460 3 60 260 GREENHECK MODEL Q0-18 -I 212 EF -2 EAST PENTHOUSE EAST BATHROOMS 18 9 I 4,720 0.75 1368 1245 RIGHT NO 0.99 1 -1/2 460 3 60 260 GREENHECK MODEL QEI -18 -I 40" EF -3 EAST PENTHOUSE 1ST FIR MECH RMS 15 9 I 1,800 0.75 776 .. 1123 RIGHT NO 0.34 3/4 460 3 60 190 GREENHECK MODEL QEI -15 -I 10 PRESSURE POWERED CONDENSATE PUMP PACKAGES • MARK LOCATION SERVICE CONDENSATE TEMP T RECEIVER STORAGE CAPACITY LBS /HR MAX HEAD pm MOTIVE STEAM PRESS PSI SPIRAX SARCO PUMP BASIS OF DESIGN SERVICE DATE • CAPACITY GALS SIZE CPP -1A MECH RM 11V7 BUILDING STEAM 212 12 10"DIAx36" 3,600 20 60 TWO 1 -1/2" PPEC SPIRAX SARCO 1488 CPP -1B MECH RM 11J6 BUILDING STEAM 212 65 20 "DIAx48" 20,000 30 60 TWO 3"X2" PTC PIVOTROL . SPIRAX SARCO NOTE: PROVIDE STEAM SEPARATOR FOR EACH PRV CPP -PA WEST PENTHOUSE HC -3 STEAM COIL 212 1.6 6"DIAx 12" 1500 10 15 APT -14 SPIRAX SARCO 7.5 CPP -PB WEST PENTHOUSE HC -4 STEAM COIL 212 1.6 6"D1Ax12" 1000 10 15 APT -14 SPIRAX SARCO 40" CPP -PC EAST PENTHOUSE HC -1 STEAM COIL 212 1.6 6" D1Ax12" 1500 10 15 APT-14 SPIRAX SARCO WEST SIDE CPP -PD EAST PENTHOUSE HC -2 STEAM COIL 212 1.6 6'D1Ax12 1000 10 15 - APT -14 SPIRAX SARCO 3 NOTE: CPP-1A & CPP-1B SHALL BE PROVIDED IN TWO SPLITS IN ORDER TO BE INSTALLED IN MECHANICAL ROOMS • YES RETURN FANS (EXISTING) SYSTEM AREA SERVED MARK CFM S.P. " H2O OUTLET VEL WHELL DIA WIDTH CLASS RPM BRAKE HP MOTOR* VFD ** BASIS OF DESIGN SERVICE DATE - HP VOLTS PH HZ AHU-1&2 EAST SIDE R -13 28,000 5/8" 1488 40" DWDI 1 420 4 7.5 460 3 60 YES AMERICAN STANDARD IND DMSION, DETROIT SIZE 402 NOTE: PROVIDE STEAM SEPARATOR FOR EACH PRV AHU -1 &2 EAST SIDE R -14 , 28,000 5/8" 1488 40" DWDI I 420 4 7.5 460 3 60 YES AHU -3&4 WEST SIDE R -11 28,E 5/8" 1488 40" DWDI I 420 4 7,5 460 3 60 YES AHU -3 &4 WEST SIDE R -12 28,000 5/8" 1 488 40" DWDI I 420 4 7.5 460 3 60 YES *: PROVIDE NEW 7.5 HP MOTOR * ELECTRICAL CONTRACTOR TO PROVIDE NEW VFD STEAM PRESSURE REDUCING VALVE SCHEDULE MARK LOCATION CAPACITY (LBS/HR) VALVE SIZE (IN) INLET PRESS (PSI) D PRESS (PSI) STRAINER SIZE (111) SARCO DATE OF SERVICE PR1/ -1 WEST PENTHOUSE 1300 3/4 125 15 1-1/2 25P (PILOT OPER) PRV-2 WEST PENTHOUSE 3900 1 -1/2 125 15 3 25P (PILOT OPER) PRV-3 MECH ROOM 11V7 50 1/2 125 60 3/4 i 251YIP (DIRECT OPER) NOTE: PROVIDE STEAM SEPARATOR FOR EACH PRV t i s■ AIR HANDLING UNIT SCHEDULE SYSTEM AHU -1 AHU -2 MU-3 AHU -4 AREA SERVED 9 -98, EAST SIDE 9 -98 EAST SIDE 9 -98, WEST SIDE 9 -98, WEST SIDE Qt 2 1 2 1 MARK S -IA & SIB CFM 30,000 3.3 ESP TSP (IN) (IN) S -2 35,000 2.9 s -3A & 30,000 3.3 S38 6 5 6 SUPPLY FANS TYPE RPM PLENUM PLENUM PLENUM 1067 899 1067 S 35,000 2.9 I 5 IPLENUM1 899 VFD YES YES YES YES MOTOR HP 50 each 50 50 each 50 BRAKE HP 43 42.25 43 42.25 MARK CC -1 CC -2 * LEAVING AIR TEMPERATURE SHALL BE 54F AFTER SUPPLY FAN. * * STEAM COIL SHALL BE SIZED FOR 20,000 CFM FROM 25F TO 60F AND WTTH A MAXIMUM PRESSURE DROP OF 0.2" AT 60,000 CFM. NOTE: TOTAL ELECTRICAL LOADS: MU-1 & AHU -3: MCA= 146.25, MOCP =200 AHU -2 & AHU -4: MCA= 81.25, MOCP =125 CFM 60,000 60,000 D 80 'f 80'F ENT AIR 3 WB 63'F 63'F LVG AIR* DB WB 52T 51T 52T 51'F MAX 0.6 0.6 COOLING COILS AP } (1 CHILLED WATER N ENT GPM 316 316 42T 42'F LVG 54T 54'F ROWS 6 6 PRESS. DROP 10 FT 10 FT COIL SIZE 4054 "x83" 4054 "x 83" MARK HC -1 HC -2 HC -3 HC -4 CFM 20.000 (60,000) 35.000 20,000 (60,000) 35,000 ENT AIR 25T 60'F 25'F 60'F LVG ** AIR 60'F 95'F 60'F 95F APD (IN) 0.2 0.15 0.2 0.15 HEATING COILS STEAM MBH 756 1323. LBS /HR 787 1378 756 I 787 1323 137 1378 ROWS 1 1 1 1 PRESS. DROP 0.3 FT 0.3 FT 0.3 FT 0.3 FT COIL SIZE 2048X120" 30 30 30 2 0 45 "x106" 30 2 0 45 "x106" 2 0 48 "x120" . EFF PRE ALTERS SIZE 2 "x24x24 2 "x24x24 2 "x24x24 2 "x24x24 FINAL FILTERS EFF 85 85 85 85 SIZE 12 "x24x24 12 x24x24 12 x24x24 12 x24x24 BASIS OF DESIGN TEMTROL TEMTROL TEMTROL TEMTROL REMARKS COLD DECK HOT DECK COLD DECK HOT DECK DATE OF SERVICE 9- 98I1ION IMMIX 4140799 -00 er aaE 08.15.06 sr • 1141514EZAV* VAIN ACCEPTABILITY yip titan US DEIGN N . a SPECfICA10 1 irmwY APPROVED 8r OWL ISSUED FOR CONSTRUCTION I OAIE CHECKID 07.25.06 07.2506 MECHANICAL MASTER 14106,-.1q8 FMAN R61�EERS 1601 fl h ,venue Sage 900 Seattle, Iloshivten 98101 -1625 206 623 0717 For 206 624 3715 MECHANICAL SCHEDULES 9-98 RENOVATION BUILDING 996 • DEV. CENTER,WA OMMONNOWN 4140799 -00 M2A '06 "0` 140799 -00 MG 9-- 98 -M2A Ct � P . PE RMIT CE 4 COP NO- 1 08.15.06 O- 08.15.06 t •1 • 6 / //A MINI/ 411114111.1,1 AI• SEMI - INSTANTANEOUS W ATER H EATER SCHEDULE TAG SERVES LOCATION MWP (PSIG) CAPACITY (GPM) INLET TEMP F OUTLET TEMP F CONNECTIONS (IN.) STEAM COND. PSIG UNIT POWER REQUIREMENTS UNIT WEIGHT FULL (LBS.) BASIS OF DESIGN SERVICE DATE REMARKS cw HW LB /HR PSIG VOLTS PHASE AMPS WHPIR5A DOMESTIC PENTHOUSE 1500300'F 18 40 120 1.25 1.25 720 15 2 115 1 2 50 PATTERSON -KELLY PK 18D DIRECT DOUBLE WALL HEAT EXCHANGER PROVIDE W/ F &T TRAP. ASME (SECTION 8) VESSEL 115 PUMP (PU) SCHEDULE MARK NUMBER SERVICE FLUID TEMP •p CAPACITY SIZE (IN) CONSTRUCTION PERFORMANCE MOTOR AMP TYPE BASIS OF DEIGN � DATE REMARKS GPM TDH SUCT DISCH BODY FITTINGS � NPSHR ORI4E TYPE HP YOLTS PH HZ RPM PUPIP5A DOMESTIC HOT RECIRC WATER 120 5.0 25 1 1 BRONZE BRONZE 50 - DIRECT 0.25 115 1 60 1750 INUNE KOHLER INVITATION K -2098 START-STOP AS PROGRAMMED BY BUILDING DDC SYSTEM BELL & SERIES 60 P -4 LAVATORY 1-1/2 1 1/2 1/2 • WALL HUNG I KOHLER CHESAPEAKE K -1728 (4 "CENTERS) SLOAN ETF -600 TRANSFORMER ELF -342 P -5 SHOWER 2 1 -1/2 1/2 1/2 GG RAB ELCOAT STALL W/ SEAT BARS & SET STALL, ON FULL BED GROUT STALL: LASCO 1603 RISC COLOR: BONE PLUMBING FIXTURE SCHEDULE MARK NUMBER DECRIPITION CONNECTION (INCHES) TYPE REMARKS BASIS OF DESIGN SAN VENT HW CW FIXTURE FAUCET /FLUSH VA. {MIXING VA) SPOUT FOR ACCESSORY DRAIN TYPE P -1 WATER CLOSET 4 2 - 1 -1 /4 WALL-HUNG KOHLER KINGSTON K -4330 SLOAN OPTIMA ROYAL NO. 111 ES SEAT: OLSONITE 95SSC • P -2 URINAL - 2 1 -1/2 - 3/4 WALL -HUNG FLUSH VALVE (H) HANDICAP K-4960 BARDON K -4960 ET SLOAN SP- S186- 10.ES -S -BOE W /EL 518 A -BOE P -3 LAVATORY 1 - 1/2 1 - 1/2 1/2 1/2 COUNTERTOP ELEC. SENSOR (120V TO COMMON TRANSFORMER) KOHLER INVITATION K -2098 SLOAN ETF -600 TRANSFORMER ELF- 342(ONE PER 3 LAVATORIES) P -4 LAVATORY 1-1/2 1 1/2 1/2 • WALL HUNG DEDICATED TRANSFORMER KOHLER CHESAPEAKE K -1728 (4 "CENTERS) SLOAN ETF -600 TRANSFORMER ELF -342 P -5 SHOWER 2 1 -1/2 1/2 1/2 GG RAB ELCOAT STALL W/ SEAT BARS & SET STALL, ON FULL BED GROUT STALL: LASCO 1603 RISC COLOR: BONE CHICAGO 17621S BRASS BODY W /STAINLESS STEEL GRID P -6 ELECTRIC WATER COOLER 1-1/2 1 1/2 - 1/2 WALL HUNG PROVIDE WATER FILTER 120 120 V -10 ELKAY EROM28RAC _ ALTER: EVERPURE 9-1/2" H54 SERIES W / - HE AD P -7 SINK 2 1 -1 /2 1 /2 1 /2 SINGE COMPARTMENT COUNTERTOP, STAINLESS STEEL ELKAY MAD-1919 CHICAGO 201 AHA -8 GRID P -7.1 SINK 2 1 -1 /2 1 /2 1 /2 SINGE COMPARTMENT COUNTERTOP, STAINLESS STEEL ELKAY LRAD -1716 CHICAGO 2302 GRID P -8 SERVICE SINK 3 2 1/2 1/2 FLOOR MOUNTED KOHLER WHITBY 6710 W /GUARD CHICAGO 956R -369 P -9 NOT USED P -9A NOT USED P -9B NOT USED P -10 NOT USED FD -1 FLOOR DRAIN VARIES VARIES - - 1/21 PRIMER (SAN ONLY) SEE PLAN FOR SIZE SMITH 2010 -13 . STRAINER:SQUARE NICKLE- BRONZE FD -2 FLOOR DRAIN VARIES VARIES - - 1 /2"TRAP PRIMER SEE PLAN FOR SIZE SMITH 2630 FFD_1 FLOOR DRAIN VARIES VARIES _ _ 1 /21RAP PRIMER SEE PLAN FOR SIZE SMITH 3510 -F19 SYS COMPUTER ROOM COOLING UNIT (AC) SCHEDULE MARK LOCATION NUMBER (ROOM NUMBER) ACT J7 DCN RM 11K6 UEBERT MINI -MATE2 ACT K8 AC2J7 AC2P7 ELEV EQ 121(7 DNC RM 21J6 NCO LAB 22N6 MAKE UEBERT MINI -MATE2 UEBERT MINI -MATE2 UEBERT SYSTEM 3 MODEL MMD40C 3 MMD23C 1.5 MMD40C UH376C NOMINAL CAPACITY TONS • 3 20 DRNE TYPE DIRECT DIRECT DIRECT DIRECT FAN CAPACITY 1250 750 1250 9100 ESP INWG 0.3 0.3 0.3 0.35 FAN MOTOR HP 0.5 0.2 0.5 CAPACITY MBH SENSIBLE 27305 14,900 27305 7 1/2 205,800 COIL COOLING CAPACITY TOTAL 30085 15,700 30085 236,900 ROOM TOP ( F) DB 75 75 75 75 FLOW GPM 6 3.1 6 CHNJ ED WATER Ewr 45 45 45 MAXPDOMAX FLOW FT H2O 5.7 4.2 5.7 46.8 45 I 7.4 TYPE & DEPTH 2 2 2 4 AIR FILTER EFFICIENCY PER ASHRAE 52 -76 30% 30% 30% 60% MAX FINAL SP WG VOLTS 208 208 208 460 ELECTRICAL PHASE 3 3 3 3 FLA 2.8 1.4 2.8 56.6 WSA 3.5 1.8 3.5 70.8 OPD 15 15 15 80 REMARKS FACTORY FILTER BOX, FILTER CLOG SWITCH, 2 WAY VALVE, CONDENSATE PUMP, LIQUI - TECT LEAK DETECTION SENSOR WITH A 6' LONG WIRE TO UNIT, DISCONNECT FACTORY FILTER BOX, FILTER CLOG SWITCH, 2 WAY VALVE, CONDENSATE PUMP, UQUI -TECT LEAK DETECTION SENSOR WITH A 6' LONG WIRE TO UNIT, DISCONNECT (1) 7.5 HP FAN MOTOR, 2 WAY VALVE, 46.2 CV, UP FLOW MODEL WITH FACTORY RETURN GRILLE, CONDENSATE PUMP, INFRARED HUMMER, ELECTRIC HEAT 98.1 MBH, IJQUI -TECT WATER DETECTION, HIGH EFFEICENGY FILTERS, SMOKE DETECTOR, DISCONNECT A 9-98 RENOK1fll4 • 14140799.00 comma • 11.501116% OW m 08.15.06 • AWAREZAKM° • 1 1 10 M ACCEP`fABtthY comivi 111S Mei HOAR ellERE1) 07.25.06 APPROVED SY • DEP. ISSUED FOR CONSTRUCTION ORE 0725.06 NILE LEpwMcK wAsifle Oi FACTORY FILTER BOX, FILTER CLOG SWITCH, 2 WAY VALVE, CONDENSATE PUMP, UQUI -TECT 410 POINT LEAK DETECTION SENSOR WITH A 6' LONG WIRE TO UNIT, DISCONNECT AFPF FM AN IGINEERS 1601 Fib Moue Sub 900 Seo10k Ilbstibgton 98101 -1625 206 623 0717 Fax 206 624 3775 MECHANICAL SCHEDULES 9-98 IEIpAl11RN BUILDING 9.96 • DEV. CENTER.WA CMOS BENSON J 140799 -00 M26 JOS "°` 140799 - 00 ONO NO. 9- 98 -M28 :ECtiED ;nvnFr. r. v e'_t cc? 1 `i PE;411 i CENTER ORE COP NOL 08.15.06 1 DIFFUSER AND GRILLE SCHEDULE MARK TYPE NECK SIZE NC MAXIMUM DESIGN CFM DUCT CONN`_CTION SIZE BASIS OF DESIGN B REMARKS ROUND SQUARE CD1 24x24 SQUARE CEIUNG DIFFUSER 60 25 100 — — TITUS TMSA LAY —IN CELING CD2 24x24 SQUARE CEIUNG DIFFUSER 80 25 210 — — TffUS TMSA LAY —IN CELING CD3 24x24 SQUARE CEIUNG DIFFUSER 100 25 380 — — TITUS TMSA LAY —IN CELING CD4 NOT USED C 150 700 8 SEE NOTE 6 SEE NOTE 6 CD5 24x24 SQUARE CEIUNG DIFFUSER 140 25 750 — — TITUS TMSA LAY —IN CEUNG CD6 LINEAR SLOT CEIUNG DIFFUSER 100 25 235 — 1 — TITUS 180I -30 4' -0" LONG (3) 1" SLOTS C07 UNEAR SLOT CEILING DIFFUSER 120 25 i 280 — — TITUS TBDI -30 4' -0" LONG (3) 1" SLOTS CD8 NOT USED F 450 2000 14 SEE NOTE 6 SEE NOTE 6 20x16 CD9 OUND R ROUND 80 25 210 — — TITUS TMRA 16 CD10 ROUND DIFFUSER 100 25 380 — — TITUS TMRA CD11 12x12 SQ CEILING DIFFUSER 80 25 210 TITUS TMSA SURFACE MOUNT CD12 12x12 SQ CEILING DIFFUSER 101ti 25 380 TITUS TMSA SURFACE MOUNT CD13 UNEAR SLOT DIFFUSER 80 25 250 TITUS FLOW BAR 4' -0" LONG (1) 1.5' SLOT SG1 HIGH WALL SUPPLY GRILLE SEE PLANS 25 SEE PLANS — — TITUS 300R1 RG1 NOT USED RG2 NOT USED RG3 NOT USED RG4 NOT USED RG5 NOT USED RG6 NOT USED RG7 CEIUNG RETURN GRILLE 22x10 25 • 450 120 22x6 TITUS 350RL RG8 CEIUNG RETURN GRILLE 22x16 25 1100 80 22x8 TITUS 350RL RG9 CEIUNG RETURN GRILLE 22x22 25 1650 80 22x12 TITUS 350RL RG10 NOT USED RG11 NOT USED RG12 SIDE WALL RETURN GRILLE 18x16 33 1250 — — TITUS 350RL RG13 SIDE WALL RETURN GRILLE 14x18 29 750 — — TITUS 350RL EG1 CEILING EXHAUST GRILLE 8x8 25 200 80 8x6 TITUS 35ORL EG2 CEILING EXHAUST GRILLE 10x10 25 350 100 12x6 TITUS 350RL EG3 NOT USED 25 500 120 14x8 TITUS 35ORL EG4 NOT USED EG5 NOT USED EG6 NOT USED 1 EG7 COLING EXHAUST 22x10 25 700 120 22x6 TITUS 35ORL EG8 NOT USED EG9 NOT USED EG10 NOT USED EG11 NOT USED EG12 H WALL EXHAUST GRILLE SEE PLANS 25 SEE PLANS — — TITUS 350RL TG1 HIGH WALL TRANSFER SEE PLANS 25 SEE PLANS — — TITUS 350RL_ DUAL , DUCT TERMINAL UNIT SCHEDULE MARK COLD DUCT HOT DUCT OUTLET DUCT SOUND POWER ADDITIONAL SOUND ATTENUATION REMARKS TYPICAL SETPOINT RANGE COLD DUCT INLET SIZE MAXIMUM HOT DUCT CFM (PER PLANS) HOT DUCT INLET SIZE 2 4 6 LOWEST MIN. ' HIGHEST MAX. A 50 170 4 SEE NOTE 6 SEE NOTE 6 12x8 64 56 56 NOT REQUIRED B 80 340 6 SEE NOTE 6 SEE NOTE 6 12x8 62 59 56 NOT REQUIRED C 150 700 8 SEE NOTE 6 SEE NOTE 6 12x10 65 60 58 NOT REQUIRED D 230 1000 10 SEE NOTE 6 SEE NOTE 6 14x14 72 3 3 59 NOT REQUIRED E 330 1400 12 SEE NOTE 6 SEE NOTE 6 16x14 72 59 NOT REQUIRED F 450 2000 14 SEE NOTE 6 SEE NOTE 6 20x16 73 61 61 NOT REQUIRED G 580 2600 16 SEE NOTE 6 SEE NOTE 6 24x16 73 61 61 NOT REQUIRED • SAS A 1. REFER TO FLOOR PLANS FOR SIZES OF WALL AND DUCT — MOUNTED GRATES AND REGISTERS. 2. DIFFUSERS SHALL NOT EXCEED NOISE CRITERIA (NC) PER THE SPECIFIED BASIS OF DESIGN MANUFACTURER'S TESTING STANDARDS, EXCEPT N MECH RMS., ELEC RMS., & ELEV EQUIP RMS. 3. REFER TO ARCHITECTURAL REFLECTED CEILING PUNS FOR COORDINATION OF DIFFUSERS AND GRADES WITH OTHER (SING EWAEHTS. CONTRACTOR SHALL VERIFY CE1U NG TYPES AV ALL AREAS AHD CONFIRM BORDER STYLES PRIOR TO ORDERING (SUES, REGISTERS AND DIFFUSERS. 9-98 RENCNAHON 4140799 -00 Cofftiw • • OP E 0115.06 • 1. DESIGN BASED ON TITUS DEDV SERIES TERMINALS WITH FACTORY— INSTALLED CONTROLS FURNISHED BY CONTROLS SUBCONTRACTOR. 2. TERMINAL UNIT ASSEMBLY INCLUDES AIR VALVES, CONTROLLERS AND MIXING — ATTENUATOR SECTION. TERMINAL UNIT COLD AIR VALVES SHALL BE ABLE TO OPERATE AT ANY POINT WITHIN THE SETPOINT RANGE INDICATED IN THE SCHEDULE. INITIALLY SET MAXIMUM AND MINIMUM CFM'S AT VALUES INDICATED ON THE PLANS FOR EACH INDMDUAL TERMINAL. 3. SOUND POWER VALUES SCHEDULED ARE THE MAXIMUM ALLOWED DISCHARGE SOUND POWER AT THE "MIXER—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x14 SOUND POWER 2 72 4 60 6 59 ADDfT10NAL SOUND ATTENUATION NOT REQUIRED REMARKS SOUND ATTENUATOR (SA) SCHEDULE MARK NUMBER AIR HANDLER UNIT ATTENUATOR LENGTH BANK SIZE FEET FT x FT UNIT WIDTH x HEIGHT INCHES MAXIMUM AIR MINIMUM DYNAMIC INSERTION LOSS RATING, dB PD FY FPM QUAY OCTAVE BAND CENTER FREQUENCY HERTZ IN /H20 CFM RATING 63 125 250 500 1000 2000 4000 8000 BASIS OF DESIGN SA-1 SA-2 SA-4 AHU -1 AHU -2 AHU -3 AHU -4 96X96 72X72 96X96 72X72 5 5 5 5 48X48 (4) 48X36 2 36X24 2 48X48 (4) 0.25 0.25 0.25 481(36 (2) 0.25 36X24 (2) 1150 1150 1150 1150 60,000 35,000 60,000 35,000 10 10 10 12 12 12 21 21 21 23 23 23 10 12 I 21 23 22 22 22 22 16 16 16 16 12 12 12 12 10 10 10 10 LAC MODEL 'CLEAN FLOW' TYPE HLFM VC MODEL "CLEAN FLOW" TYPE HLFM IAC MODEL 'CLEAN FLOW" TYPE HLFM LAC MODEL "CLEAN FLOW" TYPE HLFM +?;LArOE av"• • ACCEPTABIL.IIY WAS RiVOR 1! Br • OUT ISSUED FOR CONSTRUCTION I ORE COMPS MEM IISOTURA 07.25.06 MECHANICAL WASTER AMPF FMAN IGHIEEKS 1601 Ala liwenve Say 900 soak Washigtat 96101 -1625 206 623 0717 For 206 624 3775 MECHANICAL SCHEDULES 9-98 RENOVATION BUILDING 9-98 DEV. CENTER,WA • UMW 4140799 -00 cos NO. 140799 -00 ONG NO. M2C 9- 98 —V2C RECEIVEG 13 PER-WI CEJTE#s COMP NO. 08.15.06 1 4 H -0 550 C -230 810 H -0 745 C -705 1410 H -0 700 C -670 1335 H -0 1000 C -450 1465 • M ■■■■t 11111011 !C ' C -115 2 120 OF ICE RELOCA1E BUSINESS/ON 4 RUING E 9-98 SlitUCTURPL UPGRPCJE 43703445 -05 H -0 700 C -600 1230 H -0 715 C -230 925 H -0 2000 C -450 2000 12x12 PRIVACY H -025 C-235 •00 H -0 70 C -65 130 H- I 715 C -2 1 + 925 H -0 430 C -150 600 H -0 980 C -815 1645 H -0 910 C -235 730 FIRST FLOOR DUCTWORK PLAN LEGEND SQUARE CEILING DIFFUSER LINEAR SLOT DIFFUSER ROUND CEILING DIFFUSER CEILING GRILLE • RETURN OR EXHAUST THERMOSTAT - WALL MOUNTED DUAL -DUCT VAV TERMINAL UNIT VOLUME DAMPER CO2 SENSOR TEMPERATURE CONTROL PANEL PRESSURE TRANSMITTER DIFFUSER /GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. H -0/510 VARIABLE VOLUME TERMINAL UNIT C- 80/925 TAG. HOT AND COLD DUCT MINIMUM AND MAXIMUM CFM 5 VALUES INDICATED. SEE DETAIL FOR ADDITIONAL INFORMATION. GENERAL NOTES 1 1 RETURN AIR PATH ABOVE MECHANICAL ROOM 11C7 TO RETURN AIR SHAFT AT SECOND FLOOR. r2> COLD DUCT INLET SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT INLET SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOLING AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAW COOLING AIRFLOW. REFERENCE DRAWINGS M2C, MECHANICAL SCHEDULES M505, HVAC DETAILS CONSTRUCTION NOTES TRANSFER GRILLE MOUNTED IN WALL ABOVE CElLNG, WITH SWNDLINED BOOT. SEE DETAIL /� ' 1 M506 (3) TEMPERATURE CONTROL PANELS STACKED ON TOP OF EACH OTHER BY CONTROLS CONTRACTOR. [:=-CONNECT TO O(IS11NG 24x10 DUCT SERVING CONNECTING LINK. EXISTING DUCT SUPPLIES CONNECTING LINK FROM SECOND FLOOR CQUNG. 13 O nnor 1M1 1 KEY PLAN SOLE NONE 8' 4' 0 4' SCALE: 1/8` =1' -0' J1140799 - 0o 08.15.06 04.24.01 11.1&02 081506 BOE /NO • ARE 1 MEcHwacx MASTER 9 -98 REIIONATION BUILDING 9-98.1 COL A-q. -u • DEV. CENTER.WA ONG NO. 9 -98 -1[10 • t IN ID .� n ►� i��������.►��,�_�� i . AWED WV BODE AT 1-3 H -0 1000 C -330 1390 N NIM ttelln P.01MRE 4.5 01 SWORE FIRST FLOOR DUCTVMORIC PLAN 9-98 RENOVA110N BUILDING 9-98.1 MEGIAlRGY. VASTER OOI. F- 1/1 -13 NNE DEV. CENTER,WA °'s "a MUM ROMPS S11e011. J # 140799 -00 SHEET JOB nal 1M11 703445 -15 J 9 -98 -11111 DATE 08.15.06 COUP NM C AOOED vAv BOx AT G-3 0 i RELOCIOE Bid / fR& E RELOCATE I1t/OONTRAC1SfRO cEv 4774011 -10 4790773 -LO 4190034 -00 4190097 -00 SR KGP KGP 1 H -0 1 SYv MOON 01.1597 F MOM 9-98 SIR1Efl M. 184INE 08.1997 G COMM RECORD OWING 4703445 -06 03.1997 04.15.99 1 9-98 RENOVADON 062599 1 N B 1 r O _ . , . si 11 I' mac. - a. III amm11 4111Ct ° 7 -' , 11X DUCT NOISE H -0 05 C -13 330 90 H C-1.230 ••- ■•-■•e -- _.. -Nib. 4703445 --15 4140799 -00 FIRST FLOOR DUCTWORK PLAN tar D[R GROUP DER GROUP RUM comma IPPRNED oiaE RP 04.24.01 MA 11.18402 R SQURES 04.30:03 Ms0R8A 08.15.06 UP Q• H -0 160 105 ACCEPTAB1UiY Is oESSx A� 6 er 2 195 i5 ISSUED FOR CONSTRUCTION H -0 945 C -900 1805 H -0 1075 C -230 860 H -0 465 C -450 895 0191 Ai:F* FMAN 161 E E R f 1601 Fillo Naive Sate 900 Sealed, 1, 98101 - 1625 206 623 0787 Fox 206 624 3715 • LEGEND 1 H -0/510 C- 80/925 8' SQUARE CEILING DIFFUSER LINEAR SLOT DIFFUSER Qo ROUND CEILING DIFFUSER CEILING GRILLE RETURN OR EXHAUST O THERMOSTAT — WALL MOUNTED DUAL —DUCT VAV TERMINAL UNIT VOLUME DAMPER CO2 SENSOR PRESSURE TRANSMITTER DIFFUSER /GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. VARIABLE VOLUME TERMINAL UNIT TAG. HOT AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL FOR ADDITIONAL INFORMATION. M GENERAL NOTES 1 1 RETURN AIR PATH ABOVE TO RETURN AIR SHAFT AT SECOND FLOOR. 1 COLD DUCT INLET SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT INLET SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOLING AIRFLOW AND HOT MR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAN COOLING AIRFLOW. REFERENCE DRAWINGS M2C, MECHANICAL SCHEDULES M505, HVAC DETAILS CONSTRUCTION NOTES TRANSFER GRILLE MOUNTED IN WALL ABOVE CEILING, WITH SOUNDUNED BOOT. SEE UETAIL� I ' M506 CONNECT DUCT TO EXISTING AIR CELLS AT BUILDING STRUCTURE TO SERVE SCIF ROOMS (TYPICAL). TRANSFER GRILLE MOUNTED IN WALL ABOVE (HUNG WITH SOUNOUNED DUCT TO CEILING TRANSFER GRILLE. ADJUST DIFFUSER FOR VERTICAL AIRFLOW PRIOR TO AIR BALANCING. CONNECT NEW 80 TO EXISTING. TRANSITION AS NECESSARY. CONTROLS FOR THIS UNIT SHALL BE PNEUMATIC. THERMOSTAT FOR VAV BOX IS INSIDE SCIF ROOM 13 Q1 Q Q 11113 KEY PLAN SCALE . NONE 4 0 4 ' SCALE: 1/8' =1'-0• 8 ' 5 REcGvEL• CITY nFrtinvt c S`2 1 PERMIT CENTEi 16' • • d -?� ■ .--i>. � i I L ,th. 11,■•■!.......: ,.:•������� l�� ��i� i lk). r i;;;;;;;;;•;.;•:•;• k-00441..,, Ni. I L. z ila ilk V, •,•_•,4 s's i R N, 4 ,, ,. `'.' •'. 73,. ; . ' . ' . ' . ' .' 11 \ NIN k lb 1 1■1 kli. „...:., FIRST FLOOR DUCTWORK PLAN SCALE: ,fie 1*-0 H -0/510 VARIABLE VOLUME TERMINAL UNIT TAG. HOT C- 80/925 AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL /r aunmorAL INFORMATION. M505 RETURN AIR PATH ABOVE MECHANICAL ROOM 11V7 TO RETURN AIR SHAFT AT SECOND FLOOR. COLD DUCT INLET SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT INLET SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOLING AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAN COOLING AIRFLOW. REFERENCE DRAWINGS M2C, MECHANICAL SCHEDULES M505, HVAC DETAILS CONSTRUCTION NOTES TRANSFER GRILLE MOUNTED IN WAIL ABOVE CEIUNG, WITH SOUNDUNED BOOT. SEE DETAIL ROUND CEILING DIFFUSER CEIUNG GRILLE RETURN OR EXHAUST THERMOSTAT - WALL MOUNTED PRESSURE TRANSMITTER DIFFUSER /GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. • HUDDLE 11S11 ..IIMIIIIIII■ WORK ' 001 18x12 UP STAIR i H-0 1000 1 C-380 1380 LOBBY 1tORMINI11r) IEmiI d 1 RN t• •A! t• H -0 580 C -500 990 I. I1 (?)II H -0/475 C -450 /900 H -0 1200 C -450 1650 IC -280 665 0FIkIC r ` -1 r - -1 l I OI 12x12 C -135 330 CT280 660 NUDDI 11W2 H -0 1000 C -450 1490 H -0 490 C -465 910 H -0 690 C -665 1330 H -0 500 C -230 765 20/16 a CONTRACT RECORD 061W MG .71034 -06 • a CP./KB • H -0 C -150 305 INIE RIS 0104.99 RIS 09.01.99 MIS 019.14.99 RP 0424.01 SM 0 s-9a RENCNABON 295 4 TYP) C -230 4140799 -00 /C.: 135 330 H -0 160 36/16 UP COF1r+w OM IMP errt 114' r COE 08.1506 MI J 1 a 900 14.14 } FIRST FLOOR DUCTWORK PLA sum Ve'= r-rc H-0 p rAPEAl211W* C -230 900 H -0 160 H-0 305 C -150 470 ACCEPTABILITY 111S NID/OR Br CCM OM • 0 295 ICE yam.. /.MMMMM DDI MECHAN1CAL MASTER H -0 910 C -230 730 I ISSUED FOR CONSTRUCTION H -0 430 C- 150 555 apt te AF FMAN IR 1601 Fifth laame Sole 900 Seth, Weslingten 90101 -1625 206 623 0717 Fax 206 624 3775 FIRST FLOOR DUCTWORK PLAN 9 -98 RENOVATION BUILDING 9-98.1 • LEGEND ILICJ 25 25 C0L S- Y /1 -13 DEV- CENTER.WA AO MG Mt SQUARE CEILING DIFFUSER LINEAR SLOT DIFFUSER ROUND CEILING DIFFUSER CEILING GRILLE RETURN OR EXHAUST THERMOSTAT - WALL MOUNTED DUAL -DUCT VAV TERMINAL UNIT VOLUME DAMPER CO2 SENSOR TEMPERATURE CONTROL PANEL PRESSURE TRANSMITTER DIFFUSER /GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. H -0/510 VARIABLE VOLUME TERMINAL UNIT TAG. HOT C- 80/925 AND COLD DUCT MINIMUM AND MAXIMUM CM VALUES INDICATED. SEE DETNL FOR AODfIIONAL INFORMATION. M505 GENERAL NOTES [' 1 > RETURN AIR PATH ABOVE MECHANICAL ROOM 11C7 TO RETURN MR SHAFT AT SECOND FLOOR. r7 COLD DUCT INLET SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT INLET SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOLING AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SUGHTLY HIGHER THAN COOLING AIRFLOW. REFERENCE DRAWINGS M2C, MECHANICAL SCHEDULES M505, HVAC DETAILS CONSTRUCTION NOTES TRANSFER GRILLE MOUNTED IN WALL ABOVE CEIUNG, WITH SOUNDUNED BOOT. SEE DETAIL M506 (3) TEMPERATURE CONTROL PANELS STACKED ON TOP OF EACH OTHER ITV CONTROLS CONTRACTOR. E:::: TRANSFER GRILLE MOUNTED IN WALL ABOVE CEILING WITH SOlMOUNED DUCT TO CEILING TRANSFER (MLLE. ADJUST DIFFUSER FOR VERTICAL AIRFLOW PRIOR TO AIR BALANCING. 11110 • 1�11 � i/ L 1 KEY PLAN sate NONE SCALE: 1/8' =1 -0 1M13 703445 -05 9 -98 -11113 RECEi TEL C ncrr;r�• . SEP i - PERMil GENIE COMP N0. 08.1506 e e c t a • H -0 595 C -230 825 H -0 1015 C -450 1465 •i =1 _1l • HUDDLE L2,A„ H -0 960 C -330 1290 H -0 630 C -600 1190 H -0 285 C -260 595 C -95 320 QRR 0 0 24C6 18 "0 ALUM H -( /300 C- 220/1020 PRIVAC H -0 960 C -330 129 F UDDL 21A2 H -0 450 C -150 600 H -0 760 C -720 1440 H -0 615 C- 335 885 OPE OFFI( H -0 910 C -130 730 SECOND FLOOR DUCTWORK PLAN LEGEND SQUARE CEILING DIFFUSER LINEAR SLOT DIFFUSER QO ROUND CEILING DIFFUSER CEILING GRILLE 0 RETURN OR EXHAUST 0 THERMOSTAT - WALL MOUNTED VOLUME DAMPER H -0 510 VARIABLE VOLUME TERMINAL UNff TAG. HOT C -80 925 AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL FOR ADDRIONAI. INF0RMA710N. GENERAL NOTES 1 1 > OgS11NG RETURN AIR OPENING BETWEEN FIRST AND SECOND FLOOR. 12> COLD DUCT INLET SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT INLET SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOUNG AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAN COOUNG AIRFLOW. REFERENCE DRAWINGS M2C, MECHANICAL SCHEDULES M505, FIVAC DETAILS CONSTRUCTION NOTES TRANSFER GRILLE MOUNTED IN WALL ABOVE CEILING, WITH SOUNDUNED BOOT. SEE DETAIL M506 SMOKE DETECTOR BY ELECTRICAL. CONTRACTOR. (3) TEMPERATURE CONTROL PANELS STACKED ON TOP OF EACH OTHER BY CONTROLS CONTRACTOR. ADJUST DIFFUSER FOR VERTICAL AIRFLOW PRIOR TO AIR BALANCING. A RRINT AMNON J4140799 -00 ET DUAL-DUCT VAV TERMINAL UNIT CO2 SENSOR TEMPERATURE CONTROL PANEL PRESSURE TRANSMITTER DUCT SMOKE DEFECTOR DIFFUSER /GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. 757904 -00 9 -98 -21110 0815.06 • • • • 9 -98 RENOVATION BUILDING 9 -98.2 MEptIU4fGI! A0lS1ER C04 A- F/1 -13 • DEV CENTER,WA c • s • et 1 li 1 11 1 a 12/12 ®► 1U 0 j -� - - -- T H6 '�i�i !930 ) WW1 I i 1 1f 111 i s lA t ima u c∎IN I.1<I l'; ll• sma p ...... M II II �,aT aTT i,., MUM MEW r f wow ■w Ini ulf•� ►u utr •; t 1 1 O I Fi aTa m il If 0 210 M f I • ; .{ ,. • : , ► I m il Ii - •ie 72/14 �• I .a_ — i - ------ --- -- -- H -0 1810 C -580 239 4180014 -00 H -0 1250 1 C-1140 2400 OPEN I FI ICE ) - 211K8 a 1 f I H -0,120 i J10 C -9 ; 1950 o�aE SYM 01.15.97 E 12.04.88 r 06.26.99 120 36 16 UP H -0 150 C -90 310 Ii11111111111�►111111 u Ipu!H _ 18 16 k • _�'} 1 STAIR L i■■e - 7w,..rs a — — 1 j� � � i 21K6 �, iii. '' ' `' stg mama ! H -0/215 C- 250/540 H -0800 C -760 150 H -0 100 C -90 190 WORK ROO i E3 X2 H -0 '15 C -86► 1720 H -0 A 15 C -200 630 OFFICE H -0 180 C -260 405 1.15.97 H -0 975 C -140 780 SECOND FLOOR DUCTWORK PLAN H -0/510 C- 80/925 LEGEND SMOKE DETECTOR TRANSFER GRILLE WITH SOUNDUNED TRANSFER GRILLE SQUARE CEILING DIFFUSER LINEAR SLOT DIFFUSER El CEILING GRILLE RETURN OR EXHAUST OT THERMOSTAT — WALL MOUNTED VOLUME DAMPER CO2 SENSOR DUCT SMOKE DETECTOR DIFFUSER /GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. VARIABLE VOLUME TERMINAL. UNIT TAG. HOT AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL FOR ADDITIONAL INFORMATION. PRESSURE TRANSMITTER GENERAL NOTES I > COLD DUCT INLET SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT INLET SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOLING AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SUGHTLY HIGHER THAN COOLING AIRFLOW. REFERENCE DRAWINGS M2C, MECHANICAL SCHEDULES M505, HVAC DETAILS CONSTRUCTION NOTES 2M10 i% 21J,2 KEY PLAN SOLE: NONE 8' 4' 0 4' 08.15.06 D BUILDING 9-98 s1Rlxm J M. UPGRM3( • DER GROUP • 01.05.00 01.24.01 ArategrAW* • APPROVED 9-98 RENUIIAiION BUILDING 9-9 MECHANICAL MASTER OOL. F —I /1 -13 • KEV. CENTER,WA JOB NO. 703445 -15 9- 98 -2M11 1 8 REDRAW 9-98 RENOM MN H -0 945 C-450 139 H -0 985 C -450 1435 CONIRJrCT RECORD ORAWIG 05 05 0 55 _.-_.._.._ ERILDDIG 9-90 SiRUCRIiM. UPGRADE 1 4140799-00 Mola HUDDLE OFFIC OIL* 01.1597 RP 04 ( 24A1 lilt 11.1802 081506 H -0 C -535 1215 H -0 1 ' 0 C -90 10 (2)36/14 U • STAIR LOBBY J ORAGE- -- 18'0 UP (2)44 0 UP 140 DN (2)36 4 UP H -0 150 C -95 320 H -0 185 C -175 615 1WI ME Kill H-0 285 1 C- 260 555 WORK ROOM C -925 184 RENCE K4 16/14 H -0/705 C- 665/1325 SECOND FLOOR DUCTWORK PLAN SCALE: iro r -o C -220 1120 12/16 150 350 H-0 390 C -365 1410 �p �r 32/14 ACCEPTABIUW In 060/06 • OPE OFFICE 1t awn 38/14 28/14 ■.. •■•• ISSUED FOR CONSTRUCTION 1.15.97 i - 0/1025 - 160/850 MECHANICAL MASTER U H -0 705 C -665 1320 Igo AKP F iWEERS 1601 RS Maw Sake 900 UM, Washington 96101 -1625 206 623 0717 For 206 624 3715 SECOND FLOOR DUCTWORK PLAN 9-98 RENOVATION BUILDING 9 -98.2 COL L-S/1-13 • LEGEND H -0/510 C- 80/925 OEV. CENTER,WA 8 ' ONG NO. SQUARE CEILING DIFFUSER LINEAR SLOT DIFFUSER ROUND CEILING DIFFUSER CEILING GRILLE RETURN OR EXHAUST THERMOSTAT - WALL MOUNTED DUAL -DUCT VAV TERMINAL UNIT VOLUME DAMPER CO2 SENSOR DUCT SMOKE DETECTOR DIFFUSER /GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. VARIABLE VOLUME-TERMINAL UNIT TAG. HOT AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL c FOR ADDITIONAL INFORMATION. PRESSURE TRANSMITTER GENERAL NOTES 1 1 > RETURN AIR PATH TO MECHANICAL PENTHOUSE ABOVE. (2 > COLD DUCT INLET SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT INLET SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOLING AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAN COOLING AIRFLOW. REFERENCE DRAWINGS M2C, MECHANICAL SCHEDULES M505, HVAC DETAILS CONSTRUCTION NOTES TRANSFER GRILLE MOUNTED IN WALL ABOVE cauNC, WITH SOUNDUNED soot. SEE DETAIL l 1 M506 SMOKE DETECTOR BY ELECTRICAL CONTRACTOR. 13 O1 21.110 21.111 21113 0 KEY PLAN SOLE NODE 4' aw MOON J 1140799 -00 SKET 0 4' SCALE: 1/8' =1' -0' 2M12 JDe N°` 1000757904 8 9-98 -2M12 M505 RECE EL/ CCTV r7 Ti : CEP 1 j PERMIT CENTEr 16' 08.15.06 e a C -55 1085 E' EN OFFIC 0 310 12 18 H -0 625 0 99 unmet III1I1II11 H -0 1885 -200 755C-840 170 OFFIC 21U4 20 16 MIIKON ■t• N�i r H -0 1405 C -450 1855 H -0 500 C -550 1120 H -0 510 C- 150 660 01.15497 042501 11.18,02 O&15406 C -205 440 ?; LAVAPPEIVAIW* � H -0 150 C -90 310 HUDDLE H -0 1040 C-150 865 H -0 350 C -100 450 SECOND FLOOR DUCTWORK PLAN 9-98 RENOVATION BUILDING 9-98.2 IEpNtll('I{L WASTER COL S-Y/1-13 LEGEND SQUARE CEILING DIFFUSER LINEAR SLOT DIFFUSER H -0/510 C- 80/925 ROUND CEILING DIFFUSER CEILING GRILLE RETURN OR EXHAUST THERMOSTAT - WALL MOUNTED DUAL -DUCT VAV TERMINAL UNIT VOLUME DAMPER CO2 SENSOR TEMPERATURE CONTROL PANEL PRESSURE TRANSMITTER DUCT SMOKE DETECTOR DIFFUSER /GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. VARIABLE VOLUME TERMINAL UNIT TAG. HOT AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL FOR ADDITIONAL INFORMATION. GENERAL NOTES r7 EXISTING RETURN AIR OPENING BETWEEN FIRST AND SECOND FLOOR. COLD DUCT INLET SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT INLET SIZE SWILL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BNANGNG SHALL BE DONE WITH MAXIMUM COOLING AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAN COOLING AIRFLOW. REFERENCE DRAWINGS M2C, MECHANICAL SCHEDULES M505, HVAC DETAILS CONSTRUCTION NOTES M506 SMOKE DETECTOR BY ELECTRICAL CONTRACTOR. (3) TEMPERATURE CONTROL PANELS STACKED ON TOP OF EACH OTHER BY CONTROLS CONTRACTOR. TRANSFER GRILLE MOUNTED IN WALL ABOVE CEILING WITH SOUNDUNED DUCT TO CEILING MOUNTED TRANSFER GRILLE. @ O1 / ® 2M10 2Y11 0 2U12 9- 98 -2M13 08.15.06 • • • • • • • a euRaw; 9-98 sTRUCTORM UPGRADE oaemacr RECORD OWNING t -J� HUDDLE' HUDDLE 437'03445-05 4140799 -00 mr Ke RR GROUP RR GROUP' caws • PRIVACY 1110101 PRIVACY 111F10 AVE 01.1597 RP 0424.01 IN 11.18.02 N%R A 041.15106 OPEN OFFICE 1 12010 I MAIM SMALL OFFICE 1 12C9 SMALL OFFICE 9 C RRIDOR 12V7 I et MECH. 11C7 0 1 CONFERENCE 1186 I STAIR CAFE 111D6I CORRIDOR 11TE FIRST FLOOR HVAC PIPING PLAN SCALE: 1/8 r-o 1 Q�BOE /NO• v - PRIVACY � 12C4 J PRIVACY 1 1104 13> A CEP A8U WAN I caw ORD/OR • • OPEN OFFICE 1 11E5 1 COT NOE MOM WOE A ISSUED FOR CONSTRUCTION MECHANICAL MASTER 9 -98 RENOVATION BUILDING 9 -98.1 OOL. A- F /1 -13 APF FMAN IGINEERS 1601 FRI% Awe See 900 Wasliitglon 90101 -1625 206 623 0717 fn 206 624 3715 FIRST FLOOR HVAC PIPING PLAN OEV. CENTER,INA LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES NO WORK ON THIS SHEET 114 l 1M61 1462 8 ' SCALE: 1/8 -O" CURREM RL11OIOH AWOL 4140799 -00 JOB Na 703445 -05 ONG Mk KEY PLAN WM: NONE 4' 0 4' 1M60 8 9-98-11460 COUP PM ECEi• • E • `.EP 1 ' J J1_ PERMiT CENTF:!.: 16' 08.15.06 • • t 0 • 1 01.15.97 04.24.01 11.1&02 0&1506 OPEN OFFICE 11F8 M�..�■IMMF..I■..∎.. -..1■10W N -N .rw+.OIMQEE. MIS.. s DCN 11K6 • 1M452 ' t1NI _ TIM 0 °W ) Ci 3 "CHWS & CHWR INTERACT CENTER CQNfERENCE 1 12E4 SMALL OFFIC 2 SMALL OFFIC 111H4I WORK ROOM OFFICE PUMPED CONDENSATE FROM BUILDING 9 -99 FFICE - 1G5 OPEN OFFICE SMALL OFFICE 1.15.97 FIRST FLOOR HVAC PIPING PLAN 9-98 RENOVATION BUILDING 9 -98.1 MECHANICAL MASTER COL F - 111 - LEGEND -pc --- MPC --- CHWS CHWR CONDENSATE RETURN (PUMPED) LOW PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM CHILLED WATER SUPPLY CHILLED WATER RETURN SHUT -OFF VALVE CAP PIPE TURNING UP PIPE TURNING DOWN GENERAL NOTES COMPUTER ROOM COOLING UNIT f /FLR, BOTTOM UNE INDICATES LOCATION REFERENCE DRAWINGS 1M452, ENLARGED MECH RM PLANS M312, STEAM SYSTEM DIAGRAM CONSTRUCTION NOTES � PROVIDE CHILLED WATER SUPPLY AND RETURN � PROVIDE 1-1/2 ISOLATION VALVES (emu). INSULATE EXISTING CONDENSATE RETURN FROM BUILDING 9 -99. NEW CEILING MOUNTED A/C UNIT FOR ELEVATOR MACHINE ROOM. NEW CEILING MOUNTED A/C UNIT FOR DCN ROOM. 6 NEW 2 -1/2' CONDENSATE RETURN (PUMPED). NEW 4" LOW PRESSURE STEAM CONDENSATE FROM PENTHOUSE. 8 NEW 4' VENT TO PENTHOUSE. 9 NEW 3/4" MEDIUM PRESSURE CONDENSATE FROM SECOND BOOR. D> NEW 1' 60 PSG STEAM PIPE. 9 --98 -1 M61 GEN 08.15.06 • • REDRAW 4-98 RENOIADON - - 6 CONIRAI.'T RECORD MAKING IMIND WPM VEST BMW 9-98 MOURN. UPGRADE 5 4140799-W KB DM GROUP RR GROW • RP 1111 USOTUIA I OPEN OFFICE i OWE 01.1597 0114.01 11.1&.012 051506 3 "CHWS & CHWR ! 11R9 • =MO MD -- CORRIDOR ( 12T5 1 -1/2" MID FIRST FLOOR HVAC PIPING PLAN 1 3 "CHWS & CHWR ArarAE'FAV* RECYCLE 1 11L3 APPROND IN • OPEN ► FF10E OFIROAD 4WD =MI -- 1.1597 VEST ISSUED FOR CONSTRUCTION I &IECHANICAL MASTER ASC)F FMAN IGINEEts 1601 Fith ,woe Sale 900 Seattle, Wodingtoa 96101 -1625 206 623 0717 Fax 206 624 3775 FIRST FLOOR HVAC PIPING PLAN 9 -98 RENOVADON BUILDING 9.98.1 COL L— s /1-13 • DEV. CENTER,WA LEGEND CHWS CHWR - MPS --- ---PC c' GENERAL NOTES CHILLED WATER SUPPLY CHILLED WATER RETURN MEDIUM PRESSURE STEAM SHUT —OFF VALVE CONDENSATE RETURN (PUMPED) CAP PIPE TURNING UP PIPE TURNING DOWN REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE CHILLED WATER SUPPLY AND RETURN LOOP. PROVIDE 1 -1/2" ISOI.ATION VALVES (TYPICAL). 1= NEW 2 -1/2' CONDENSATE RETURN (PUMPED) PROVIDE 1', 60 PSI STEAM KEY PLAN sem: NONE 8' 4' 0 SCALE: 1/8' =1' -0' COMO REV4 = J4140799 - 1M62 cos as 703445 -05 an NO. 4 ' 8' 9 -98 -11.162 i CONP NO. 16' 08.15.06 • I A 8 REDRMIN COP[ti M;r RECORD OR1118 9-98 RENOWN OFItICE CONFERENCE CORRI » MOTHER F11T7 STORAGE L1 1T6 3 "CHWS & CHWR 1-1/2" - . 1 • L. f I HUDDLE 1 1 S" i BOLCOM 9-98 SIRUCRO . uPGRP E I3703445 -05 4140799 -00 MO IMMI HUDDLE ! 2MI12 1 4 . 1 a OPEN ) FF ICE 11 ORE 01.15.97 0124.01 11.18.02 08.15.06 WORK ROOM [i 251 0 • _o- 111R9I 3 "CHWS & CHWR UP 1 -1/2" f 1 1 1 1 MIN 2 114452 LOBBY f OS ELECT. �,. 11 S6 -0 0 C DO_ R 172 A 4 FIRST FLOOR HVAC PIPING PLAN SCALE: yr- 1.-0• dONFERENCE I [i2�i j J CONFERENCE 11W41 o ------ - - - - -- - - - -;: Q�BOE /NO• � OFFI 11R eaves 1/t E a . WORK ROOM APPROVED Of -- u ACCEPTABIU1Y �6 • OEM ..r.IM...r.r.10. ■.. SMALL OFFICE I PRIVACY 1 [ 11T2 1 APPROVID HUD IE it 1.15.97 HUDDLE 11 4. 1 a ISSUED FOR CONSTRUCTION I MIMICu_ MASTER AR IEEis F 1601 Fitt ?Nes a Sale 900 Soak Wadi/Igloo 98101 -1625 206 623 0717 Fat 206 624 3T/5 FIRST FLOOR HVAC PIPING PLAN 9-98 RENOVATION BUILDING 996.7 • Mob tib LEGEND --- CHWR --- CHILLED WATER RETURN MPS MEDIUM PRESSURE STEAM PC CONDENSATE RETURN (PUMPED) SHUT—OFF VALVE CAP PIPE TURNING UP PIPE TURNING DOWN GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE CHILLED WATER SUPPLY AND RETURN LOOP. PROVIDE i -1/2 ISOLATION VALVES (TYPICAL). NEW 2 - 1/2" CONDENSATE RETURN (PUMPED). PROVIDE 1", 60 PSI STEAM COL. S Y/1 -13 DEV. CENTER A 0e-- c-}-- 13 0 0 1460 11460 11461 1 M62 43 KEY PLAN SOU: NONE 8' 4' SCALE: 1/8' = 10 " an fifve am 4140799 -00 0 4' swr 1M63 ""s N0` 703445 -05 RIG Na 8' 9 -98 -11463 t �vr1 icL T COMP N0. 16' 08.15.06 1 1 i 1 • MOM 9-98 STRUCTi1M MRS( 8 , OONIRM T RECORD OR*1VG c 19-96 RENICNATION 4140799-00 HUDDLE HUDDLE 1 220111 • OPEN OFFICE 1 218 1 21010 I SMALL OFFlC SMALL OFFIC CQRRIDO 24C6 X ameswasimiesszo I21F6I N STAIR 1 22C6 I CAFE i 1 SECOND FLOOR HVAC PIPING PLAN SCALE: , row= r-o • PRIVACY I21B4I PRIVACY 1 2284 1 SM OFFICE 1 2364 SMALL. OFFIC I21C4I SMALL - OFFIC 1 2104 I SMALL OFFIC 1 2204 I ems 1 APPROVED HY • I ACCEPTABIUlY �S OEPL 1 I ONE MED HUDDLE 1 21A2 I 1 i ISSUED FOR CONSTRUCTION I 1.1597 MECHANICAL MASIER 1\110(0-ilo � AP 1601 Fah keen Solve 900 Seattle, 11adingba 96101 -1625 206 623 0717 F®[ 206 624 3775 SECOND FLOOR HVAC PIPING PLAN 9 -98 RENOVAI1ON BUILDING 9-98.2 (kV. cENTER,WA • LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES No WORK an THIS SHEET as Mt ONG NIX 21162 8 ' 4' 1/16f Est 21463 KEY PLAN SGRE: NONE Q1RRE11i• MOM 4140799 -00 0 0 4 ' SCALE 1/8' =1'-0' 2M60 0 8' 16' 703445 -05 9 -98 -21160 O 1 08.15.06 c c _ s 0 BUILDING 9-98 STRUCTURAL UPGRADE 8 CONTRACT RECORD CRANING PRIVACY I 23G9 SMALI. OFFICE SMALL OFFICE SMALL OFRCE PRIVACY IIIIIIIIIIIIIIIIIM IIIIIIIIIUIIIIIIIIII 1ihI wimp INTERACT 1- 1 /2 "CHWS & CHWR STORAGE CENTER 11/'CHWS & CHWR 3"CHWS & CHWR SMALL OFFICE PRIVACY 1 23G1 1 OFFICE 21E2 I KB GROUP CROUP lit OPEN OFFICE ONE 01.1597 04.24.01 11.1&02 1 22G9 I I OFFlC 21J9 I 121J9 I 3 "CHWS & CHWR— ar c21 F7 CWOMEN'S 1 -1 SECOND FLOOR HVAC PIPING PLAN SCALE ./e'— r-o" •3"CHWS & CHWR 3/4" MPC DN 3 " LPCUP& 4 DN Q• 1 (VTR WORK ROOM 1 21 E3 I APPROVED BY Maw am OPE OFFICE 1 21G5 AOCEPTA8IU1Y cesas NO/OR SPONEANON OEM OM NIB HUDDLE 22E27 ISSUED FOR CONSTRUCTION I 1.15.97 AMP WEaNtICAL WASTER fitfi M I C I F I F 11 E E 1601 FiVi kat= Sate 900 Seattle. 'It ieston 96101 -1625 206 623 0717 Fax 206 624 3775 SECOND FLOOR HVAC PIPING PLAN 9-98 RENOVATION BUILDING 9-98.2 COL. F-111 -13 DEV. CENTER,WA LEGEND CHWS CHWR m pc P4 GENERAL NOTES CHILLED WATER SUPPLY CHILLED WATER RETURN LOW PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE SHUT —OFF VALVE CAP PIPE TURNING UP PIPE TURNING DOWN COMPUTER ROOM COOUNG UNIT f /FLR, BOTTOM LINE INDICATES LOCATION REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE CHILLED WATER SUPPLY AND RETURN LOOP. PROVIDE 1-1/2" ISOLATION VALVES (TYPICAL). NEW CEILING MOUNTED A/C UNIT FOR DCN ROOM. PROVIDE NEW 1 -1/2" CONDENSATE RETURN PROVIDE 4" STEAM CONDENSATE RISER TO PENTHOUSE. PROVIDE NEW 4" VENT TO ROOF. PROVIDE 3/4" MEDIUM PRESSURE CONDENSATE. CONNECT TO EXITING 4"VER. OM KEY PLAN SCALE: NONE 0 4' 8 ' 4' 8' 16' SCALE: 1/13 CURRENT REMO! 4140799 - 00 g 2M61 .1013 703445 -05 9 -98 -2161 ECE!'rE PERMIT UN' 001P ND. 08.15.06 • 1NADNG 9-98 SIRUCfl1RA1. (i GRAOf 5 8 coma RECORD ORIt1M HUDDLE 1 22K11 er ME 01.15.97 04.24.01 11.1&O2 08155.06 WORK ROOM [21K10 -- • SMALL OFFICE L21N9 • SECOND FLOOR HVAC PIPING PLAN SCALE: 1/e r-rc CONFERENCE E2 I -Iw OPEN OFFICE 1YOCEPTA81uTY 1NIS OBEN Alum PR ND ear OEM a IE • - w MEM 1 21R5 I MED -- ISSUED FOR CON STUCTION I 1.15.97 4. MECHAN1C.AL MASTER AS °F IGINEEis 1601 Filth Anne Sob 900 Sest0e, Wadi gton 90101 -1625 206 623 0717 Fax 206 624 3715 SECOND FLOOR HVAC PIPING PLAN 9-98 RENOVATION BUILDING 9 -98.2 COL L- s/1-13 DM cater; LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE CHILLED WATER SUPPLY AND RETURN LOOP. PROVIDE 1-1/2* ISOLATION VALVES TYPICAL). ©PROVIDE NEW 4" STEAM RISER PROVIDE NEW 3" LOW PRESSURE STEAM CONDENSATE. E:;:;i PROVIDE NEW 3/4" MEDIUM PRESSURE CONDENSATE. PROVIDE NEW INSULATION FOR EXISTING 4" STEAM PIPE. LPC --- MPC---- - MPS CHWS CHWR D4 2M60 21161 21162 8' SCALE: 1/8 " =1'-0' CURRENT ROOM Sneeoe ,140799 -00 JOS NO- 703445-06 ONG ND. 4' LOW PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM CHILLED WATER SUPPLY CHILLED WATER RETURN SHUT-OFF VALVE CAP PIPE TURNING UP PIPE TURNING DOWN STEAM TRAP KEY PLAN SCALE NONE COMPUTER ROOM COOUNG UNIT fl /FLR, BOTTOM UNE INDICATES LOCATION 0 4' 2M62 C 8 9 -98 -21162 COP ND. RECt; c 1 ecT1;!!'. crP pAMe i CE�iTEF 16' 08.15.06 1 e t 3 SUMO 9-98 snwc1URAL UPGRADE HUDDLE 122S11I HUDDLE 22W12 1 OOMPH OFFICE 1 21S11 -I- E 1 OIgE 01.15.97 04.24.01 11.1802 0815.06 WORK ROOM 1 21S10 .. 1 4 "UP 3 "D• PRIVACY 1 21U9 I SMALL OFFIC L22V9 SMALL OFFIC 1 21W SMALL OFFICE .1' 1 1 CO RIDOR 4C6 IN MI —1/2 • CHWR " "• CAFE L 21S6 1 r STEAM UP & DN \ c oa�ae� � 2ix7 1 t' STEAM mt UP & oN O 3 "CHWS & CHWR 1 _ 1 / 2 "• STAIR 21V6 CONFERENCE— I21X6I f .. .. C FERENCE j 22R4j e ( , k _. _. ._ 1 1 1 SECOND FLOOR HVAC PIPING PLAN PRIVAC 21R4 PRIVAC 23T4 �l 1 O OMMMMMMMOMMWMOO 1 22R3 I APPROWD er T - OPEN OFFICE' 121T5I 21R2 I ACCEPT/OM SPEOFICARON 1s ip CEPL WOE MEM HUDDLE 1 22R2 I 1.15.97 ISSUED FOR CONSTRUCTION I 9-98 RENOVATION BUILDING 9 -98.2 AIECFIFMGIL W1S7Qt COl. S- Y /1-13 ACCIF IGINFERS FMAN 1601 Fdth Avenue Sole 900 Settle, Washington 96101 -1625 206 623 0717 Fax 206 624 3775 SECOND FLOOR HVAC PIPING PLAN • DEV. CENTER,WA LEGEND LPC FA pc OwlawaNiM■e --- MPS - -- CHWS CHWR GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE CHILLED WATER SUPPLY AND RETURN LOOP. PROVIDE 1 -1/2" ISOLATION VALVES (IYPICAL). ©PROVIDE INSULATION FOR EXISTING 4" STEAM PIPES. 8 ' OM 0 O1 21160 21161 21162 KEY PLAN SOU: NONE CLUMP REvE/ow 414099 -00 4 LOW PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM CHILLED WATER SUPPLY CHILLED WATER RETURN SHUT -OFF VALVE CAP PIPE TURNING UP PIPE TURNING DOWN 0 4' SCALE 1/8 " =1' - O" 2M63 JOB re. 703445-05 8' 9- 98- 211163 COMP NO. 16' 08.15.06 1 • COLD � DECK SMOKE DAMPER sYv �* A 9 -98 RENOY ON 3 f 140799 -00 TO FIRE ALARM & HARWIRED TO FANS HOT COLD Q HOT DECK SMOKE DAMPER SUPPLY TERMINAL is] b *: FOR CONFERENCE ROOMS AS NOTED ON DRAWINGS COFFWZ4 CHILLED WATER COIL. APPLIQUED M. 901116% CHILLED WATER OCD l e 0 SUPPLY FANS O VFD TO FIRE ALARM & HARWIRED TO FANS CAE 08.15.06 VFD O SA 0 * CHILLED WATER COOUNG G HEATING COIL COLD DECK (AHU -1& AHU -3) 0 ** *: ONLY FOR AC2P7 COMPUTER ROOM COOLING U SCAM: NONE ,Liwo Om O SUPPLY FAN HOT DECK (AHU -2& AHU -4) STEAM — oho--•+ STEAM HEATING COIL i F: m COLD VAV DUAL DUCT TERMINAL UNITS n SCALE NONE � SCALE: NONE 0'm O SUPPLY UNIT TERMINAL or 0 Li W CE 0 OA LOUVER (TYP) 10(3 DAMPERS) 2 DAMPERS) TO PENTHOUSE 00 Flo I 1 RETURN FANS 2 DAMPERS) AIR HANDLING UNIT CONTROL DIAGRAM (AHu-1 & —3 AND AHU -2 & —4 AND RETURN FANS) /i SCALE: NONE co Do • 0 ** VAV SINGLE DUCT TERMINAL U J9 EXHAUST FAN EF -1 & EF -2 n SCALE: NONE Jio AIRFLOW MAX. HOT DECK MIN. COW DECK 0.4 CFM /SQ. FT. UNOCCU. COLD DECK 0.2 CFM /SQ. FT. ACCEPTABILITY 06EN ROAR PPPROAD B OEM ORE SCALE: NONE HEATING COOLING ROOM TEMPERATURE INCREASE _ DUAL DUCT AIRFLOW DIAGRAM � NONE Jio IP 0o N EXHAUST FAN EF-3 Ali310 ISSUED FOR CONSTRUCTION 072106 07.2506 BDD • MAX. COOUNG AIRFLOW APF FMAN IGiNEEKS 1801 FAA heave Sob 900 Seo# 16:51 ioa 98101 -1625 2206 623 0717 Fox 206 624 3715 CONTROL DIAGRAMS LEGEND m D D O O D I VFD 1 O k FAN p � ELECTRIC MOTORIZED CONTROL VALVE mf'v'-sc ELECTRIC MOTORIZED DAMPER WITH END SWITCH E:: EA AIRFLOW DIRECTION REFERENCES ONG NO. TEMPERATURE TRANSMITTER ROOM TEMPERATURE SENSOR PRESSURE TRANSMITTER AIRFLOW TRANSMITTER VIBRATION TRANSMITTER CURRENT SENSOR FREEZE STAT HUMIDITY TRANSMITTER CARBON DIOXYDE TRANSMITTER MOTOR SMOKE DETECTOR (BY ELECTRICAL) VARIABLE FREQUENCY DRIVE WITH FAN START /STOP, FAN RPM OUTPUT AND FEED BACK M311, SEQUENCES OF OPERATION MOIRENT RENSoo, J # 140799 -00 sim M310 AO NO. 140799 -00 9- 98 -M310 MOP ha. SEP 1 :4: ' • +� ;tiv i Ef; 08.15.06 p rIZEFAA a• MECHAMCAL MASTER 9-98 RENOVATION BUILDING ass DU. CENTER,WA 0 2 s SEQUENCES OF OPERATION GENERAL FUNCTIONAL REQUIRMENTS A. CONTROL OF EQUIPMENT AS DESCRIBED IN THE SEQUENCE OF OPERATIONS SHALL INCLUDE: 1. TIME AND HOLIDAY SCHEDULES 2. OPTIMUM START CONTROL AS PER WASHINGTON ENERGY CODE 1412.4.2 3. ALARM WAITS AND HISTORIES 4. SUMMARY OF DATA FOR EACH ZONE 5. TREND LOGS AND HISTORICAL DATA 6. ALL SETPOINTS 7. MASTER MENU 8. DYNAMIC COLOR GRAPHIC INTERFACE B. THE FOLLOWING POINTS DESCRIPTIONS AND SEQUENCES OF OPERATION SHALL BE ENHANCED AS NECESSARY AND INCLUDED AS PART OF THE CONTROL DRAWINGS TO EXPAND AND CLARIFY INFORMATION SHOWN ON THE DRAWINGS. 1. POINTS INFORMATION SHALL BE DISPLAYED AND ORGANIZED BY SYSTEM IN DYNAMIC GRAPHIC FORM AT THE OPERATOR STATIONS. 2. IT SHALL BE POSSIBLE TO "DISCONNECT" ANY OUTPUT OR SETPOINT FROM THE AUTOMATIC CONTROL LOGIC AND ENTER A MANUAL OR STATE FROM ANY OPERATOR STATION. 3. IT SHALL BE POSSIBLE TO REPLACE ANY INPUT WITH A MANUAL VALUE FROM ANY OPERATOR STATION. 4. ALL CONTROL LOOP PARAMETERS FOR EACH LOOP SHALL BE DISPLAYED ON ONE DISPLAY. C. THE FOLLOWING COMMANDS, DISPLAY AND DATA SHALL BE AVAILABLE AT THE OPERATOR STATION: 1. AIR HANDLING UNIT A. FANS STATUS (CURRENT SENSOR PROOF) B. OUTSIDE AIR TEMPERATURE C. MIXED AIR TEMPERATURE D. SUPPLY AIR TEMPERATURE E. RETURN AIR TEMPERATURE F. COLDEST AND WARMEST ZONE, ALL ZONES SAMPLED G. DUCT STATIC PRESSURE (AVERAGING 2 SENSORS) H. ALARMS (TEMPERATURE, AIRFLOW, PRESSURE, FILTER) D. THE FOLLOWING POINTS ARE REQUIRED IF NEEDED BY CONTROL STRATEGY: 1. DIRECTLY MEASURED TOTAL SUPPLY AIRFLOW (CFM) 2. DIRECTLY MEASURED TOTAL RETURN AIRFLOW (CFM) 3. DIRECTLY MEASURED TOTAL OUTSIDE AIRFLOW (CFM) E. THE FOLLOWING POINTS SHALL BE DISPLAYED USING CALCULATED VALUES BASED UPON COMMAND POSITION UNLESS EXACT VALUES, AS INDICATED BY A FEEDBACK SIGNAL, ARE REQUIRED BY CONTROL STRATEGY: 1. FAN SPEED (PERCENT OF FELL SPEED) 2. DAMPER POSITIONS (PERCENT OF FUUL OPEN) F. AIR TERMINALS 1. CURRENT SPACE TEMPERATURE 2. OCCUPIED HEATING /COOLING SEPOINT 3. UNOCCUPIED HEATING /COOUNG SETPOINTS 4. CURRENT STATUS (HEATING /COOLING) 5. CURRENT MODE (DAY /NIGHT) 6. MINIMUM AND MAXIMUM AIRFLOW SETTING (CFM) 7. COLD DECK AIRFLOW READING (CFM) 8. HOT DECK AIRFLOW READING (CFM) 9. DISCHARGE AIR TEMPERATURE READING 10. HIGH /LOW TEMPERATURE ALARM AIR HANDUNG UNITS AHU -1. AHU -2. AHU -3 & AHU -4 A. START -STOP AND FAN SAFETIES: 1. SAFETY FEATURES: THE FOLLOWING SHALL PREVENT FAN OPERATION UNDER ANY MANUAL, BY -PASS. THESE SAFETIES SHALL BE HARD -WIRED AND SHALL NOT RELY ON DDC CONTROL B. A. DMSION 26 FIRE ALARM OUTPUT. HIGH PRESSURE CUTOUT PRESSURE SWITCH PT1 OR PT6. C. COLD DECK FREEZESTAT (FREEZE PROTECTION). D. DISCHARGE DUCT - MOUNTED SMOKE DETECTORS WILL BE PROVIDED BY DMSION 28. THE DETECTORS WILL COMMUNICATE WITH THE DMSION 26 FIRE ALARM SYSTEM. AN OUTPUT MODULE WILL BE PROVIDED UNDER DMSION 26 (IN THE GENERAL VICINITY OF THE VFD), WHICH WILL PROVIDE FIRE ALARM CONTROL OUTPUT FOR THE AIR HANDLER. DDC CONTROL SHALL REPORT SMOKE DETECTORS STATUS. 3. ACTION - NORMAL OPERATION: A. IF THE VFD CONTROL SWITCH IS IN "AUTO" AND THE EMCS IS SET TO ALLOW OPERATION OR IF THE VFD CONTROL SWITCH IS IN ON POSITION; THEN RETURN AIR DAMPERS, OUTSIDE AIR DAMPERS AND EXHAUST AIR DAMPERS SHALL START OPENING; DAMPERS SHALL MODULATE ACCORDING TO SUPPLY AND OUTSIDE AIRFLOW REQUIRED IN THE BUILDING. IF SAFETIES ALLOW OPERATION; THEN START THE SUPPLY AND RETURN FANS. THE FANS SHALL RAMP UP TO AND OPERATE AT THE COMMANDED SPEED (SEE BELOW). IF ANY OF THE ABOVE CONDITIONS CH.ANGE, THEN THE FANS SHALL STOP OPERATING. 4. ACTION - SUPPLY FANS SPEED CONTROL: A- SUPPLY FAN SHALL OPERATE AT THE SPEED COMMANDED BY THE STATIC PRESSURE SENSORS (TWO PER AIR HANDLER) LOCATED IN THE AIR DISTRIBUTION SYSTEM, EXCEPT, THE FANS SHALL NOT BE ALLOWED TO MOVE MORE THAN 1059E OF THE 'DESIGN CFM THROUGH THE UNIT AS MEASURED AT FT1, FT2 & FT3. 5. ACTION - RETURN FANS SPEED CONTROL: A. RETURN FANS SHALL OPERATE AT THE SPEED COMMANDED BY THE SUPPLY AIR FANS, EXCEPT THE FANS SHALL NOT BE ALLOWED TO MOVE - MORE THAN 105% OF THE 'DESIGN' CFM AS MEASURED AT FT4 AND FTS. THE RETURN FANS CFM SHALL BE EQUAL TO THE SUPPLY CFM MINUS EXHAUST FANS EF-1, EF 2 & EF-3 CM. THE BUILDING SHALL BE PRESSURIZED SLIGHTLY POSITIVELY/ 6. ACTION - FAN SHUTDOWN: 7. SPECIAL ALARMS: 1. A. IF THE HIGH PRESSURE CUTOUT PRESSURE SWITCH PT1 OR PT6 ACTIVATES, THE EMCS SHALL COMMAND THE UNIT TO SHUT DOWN UNTIL RESET THROUGH THE EMCS. IF THE SMOKE DETECTORS ARE ENERGIZED THE UNIT SHALL SHUT DOWN AND THE SMOKE DAMPERS SHALL CLOSE. THE FANS SHALL DECREASE IN SPEED AND STOP. ALL DAMPERS SHALL CLOSE. DAMPERS END SWITCHES SHALL CONFIRM THAT THE DAMPERS ARE CLOSED. A. FAILURE OF AHU TO PRODUCE PROPER AIRFLOW AT FT1, FT2 & FT3 FOR MORE THAN 5 MINUTES. B. DAMPERS NOT IN FULL CLOSED POSITION WHEN UNIT IS OFF. C. PROVIDE DIRECT READOUT OF FINAL FILTER PRESSURE DROP USING ANALOG SENSORS (PT). PROVIDE WARNING ALARM WHEN AT CHANGEOUT PRESSURE. D. VIBRATION TRANSMITTERS (VT) OF ALL AHU FANS SHALL SEND A WARNING ALARM TO THE DDC SYEEM WHEN VIBRATION LEVEL IS HIGHER THAN THAN SETPOINT. B. DISCHARGE TEMPERATURE CONTROL: SPECIAL INPUTS (IN ADDITION TO DEVICES SHOWN ON DIAGRAM): A. DISCHARGE TEMPERATURE SETPOINTS TT3 AND TT5. B. OUTSIDE AIR TEMPERATURE. AN OUTDOOR SENSOR SHALL PROVIDE INPUT FOR ALL AIR HANDLER CONTROLS. 2. ACTION - OUTSIDE TEMPERATURE BELOW 50 DEG.: A. AHU -1 & AHU -3: ENERGIZE THE STEAM HEATING COIL TO MAINTAIN COLD DECK DISCHARGE TEMPERATURE AT 58 DEG AS MEASURED BY TT2. B. AHU -2 & AHU -4: ENERGIZE THE STEAM HEATING COIL TO MAINTAIN HOT DECK DISCHARGE TEMPERATURE AT BETWEEN 85 TO 95 DEG AS MEASURED BY TT4. 3. ACTION - OUTSIDE TEMPERATURE BETWEEN 50 AND 75 DEG.: A. AHU -1 & AHU -3: ENERGIZE THE COLD DECK AIR ECONOMIZER AS REQUIRED FOR COOLING. MIXED AIR TEMPERATURE IS MEASURED BY TT1. IF AIR ECONOMIZER CANNOT SATISFY THE COLD DECK DISCHARGE SETPOINT, ENERGIZE THE CHILLED WATER COOUNG COIL IN ADDITION TO THE ECONOMIZER AS REQUIRED FOR COOLING. B. AHU -2 & AHU -4: ENERGIZE THE STEAM HEATING COIL TO MAINTAIN HOT DECK DISCHARGE TEMPERATURE AT BETWEEN 75 TO 85 DEG. AS MEASURED BY TT4. 4. ACTION - OUTSIDE TEMPERATURE ABOVE 75 DEG.: A. AHU -1 & AHU -3: OUTDOOR AIR DAMPER IS AT MINIMUM POSITION TO PROVIDE OUTSIDE AIRFLOW AS MEASURED BY FT6. ENERGIZE CHIVIED WATER COOLING COIL TO SATISFY COOLING SETPOINT. B. AHU -2 & AHU -4: STEAM COIL IS NOT ENERGIZED. HOT DECK TEMPERATURE SHALL BE BETWEEN 70 AND 80 DEG. 5. SPECIAL ALARMS: A. TT3 AND TT5 LEAVING . AIR TEMPERATURES 3 DEG. OR MORE ABOVE OR BELOW SETPOINT FOR MORE THAN 5 MINUTES. DUAL DUCT VARIABLE AIR VOLUME TERMINAL UNITS A. THE DUAL DUCT VAV TERMINAL UNIT SHALL OPERATE VIA THE DDC CONTROLLER. TERMINAL UNIT AIR VALVES SHALL MODULATE TO SATISFY ZONE OCCUPIED HEATING AND COOLING SETPOINTS, INITIALLY SET FOR 70 DEG. F HEATING AND 75 DEG. F COOLING (60TH SETPOINTS SHALL BE OPERATOR ADJUSTABLE). B. WHEN ZONE TEMPERATURE IS LESS THAN OR EQUAL TO HEATING SETPOINT, THE COLD DECK AIR VALVE SHALL CLOSE TO MINIMUM POSTION AND THE HOT DECK AIR VALVE SHALL MODULATE OPEN TO SATISFY ZONE OCCUPIED HEATING SETPOINT. C. WHEN ZONE TEMPERATURE IS GREATER THAN OR EQUAL TO COOUNG SETPOINT, THE HOT DECK VALVE SHALL CLOSE AND THE COLD DECK AIR VALVE SHALL MODULATE OPEN TO SATISFY ZONE OCCUPIED COOLING SETPOINT. D. EACH ZONE SHALL HAVE THE (OPERATOR- SELECTABLE) CAPACITY TO HAVE A DIFFERENT MINIMUM COOUNG AIRFLOW SETPOINT. E. THE FOLLOWING POINTS LISTED BELOW SHALL BE MONITORED FOR DISPLAY AND ALARMING THROUGH OPERATOR'S STATION. ALL POINTS SHALL BE DISPLAYED AT STATION, ALARM FUNCTIONS SHALL BE GIVEN. 1. TERMINAL UNIT ZONE TEMPERATURE (LOW AND HIGH TEMPERATURE ALARM). 2. TERMINAL UNIT AIRFLOWS (LOW AND HIGH FLOW ALARM). 3. TERMINAL UNIT DISCHARGE AIR TEMPERATURE. F. CARBON DIOXIDE SENSOR (CO2) IN CONFERENCE ROOMS SHALL MODULATE COLD DECK AIRFLOW TO MAINTAIN CO2 LEVEL BELOW SETPOINT (INCREASE AIRFLOW WHEN ROOM CO2 LEVEL INCREASE). HOT DECK AIRFLOW SHALL MODULATE ACCORDINGLY TO MAINTAIN TEMPERATURE SETPOINT. CO2 ROOM SETPOINT IS CO2 OUTDOOR LEVEL (IN PPM) PLUS 1,000 PPM ACCORDING TO ASHRAE STANDARD 62.1 -2004 USER MANUAL, APPENDIX A. NO RESET OF THE AHU'S OUTDOOR AIRFLOW IS REQUIRED. G. DURING UNOCCUPIED TIME COLD DECK GOES TO A LOWER MINIMUM AIRFLOW THAN DURING OCCUPIED TIME( 0.2 CFM /SQFT INSTEAD OF 0.4 CFM /SQFT). SINGLE DUCT VAV TERMINAL UNITS( ELECTRICAL ROOMS) A. THE SINGLE DUCT VAV TERMINAL UNIT SHALL OPERATE VIA THE DDC CONTROLLER. TERMINAL UNIT AIR VALVE SHALL MODULATE TO SATISFY ZONE OCCUPIED COOUNG SETPOINT, INITIALLY SET FOR 78 DEG. F COOUNG (OPERATOR ADJUSTABLE). B. WHEN ZONE TEMPERATURE IS GREATER THAN OR EQUAL TO COOLING SETPOINT, THE COLD DECK AIR VALVE SHALL MODULATE OPEN TO SATISFY ZONE OCCUPIED COOLING SETPOINT. C. WHEN ZONE TEMPERATURE IS LESS THAN COOUNG SETPOINT, THE COLD DECK AIR VALVE SHALL CLOSE TO MINIMUM POSITION. D. THE FOLLOWING POINTS USTED BELOW SHALL BE MONITORED FOR DISPLAY AND ALARMING THROUGH OPERATOR'S STATION. ALL POINTS SHALL BE DISPLAYED AT STATION, ALARM FUNCTIONS SHALL BE GIVEN. 1 • TERMINAL UNIT ZONE TEMPERATURE (HIGH TEMPERATURE ALARM). 2. TERMINAL UNIT AIRFLOWS (LOW AND HIGH FLOW ALARM). MISCELLANEOUS EXHAUST FANS AND SUPPLY FANS A. EXHAUST FANS (EF-1, EF -2): EXHAUST FANS SHALL BE COMMANDED ON THROUGH THE DDC AND SHALL 8E INTERLOCKED TO RUN WITH AHU -1 & AHU -2 AND AHU -3 & AHU -4. PROOF OF OPERATION SHALL BE REPORTED TO OPERATOR'S STATION. FAN FAILURE SHALL ALARM AT THE OPERATOR'S STATION. B. MECHANICAL ROOM EXHAUST FAN (EF -3): WALL MOUNTED ROOM TEMPERATURE SENSOR START FAN WHEN ROOM TEMPERATURE IS ABOVE 80 DEG. F (ADJUSTABLE SETPOINT). FAN SHALL START ONLY AFTER THE TWO MOTORIZED DAMPERS ARE PROVEN OPEN BY THOR END SWITCHES. PROVIDE ALARM TO DOC CONTROL W ROOM TEMPERATURE IS HIGHER THAN 85 DEG. F. ISSUED FOR CON STUCTION I 07.25.06 07.2506 SEQUENCES OF OPERATION 9-98 RENOVATION BUILDING 9 -98 MECHANICAL uuI[x Igo F AP 1601 Fa heave Sege 900 Sedge, lloskingtaa 90101 -1625 206 623 0717 Fat 206 624 3775 CHILLED WATER COOLI UNI AC J7 AC1K8. AC2J7 & AC2P7 A. CHILLED WATER MR CONDITIONING UNITS SHALL SERVE THE COOLING NEEDS OF THE NOTED ROOMS. THE UNITS SHALL BE COMMANDED THROUGH THE ROOM DEDICATED THERMOSTAT. B. THE DDC SYSTEM SHALL MONITOR ROOM TEMPERATURE AND PROVIDE ALARM IF ROOM TEMPERATURE IS HIGHER THAN 76 DEG. F (ADJUSTABLE) AND LOWER THAN 65 DEG. F. (ADJUSTABLE). C. SMOKE DETECTOR MOUNTED IN UNIT SHALL STOP UNIT (BY UNIT CONTROLLER). ALARM SHALL BE REPORTED TO FIRE ALARM PANEL AND TO DDC SYSTEM. DOMESTIC HOT WATER A. ALL OPERATING AND SAFETY CONTROLS FOR THE DOMESTIC HOT WATER HEATER WHP1R5A SHALL BE FACTORY FURNISHED AND WIRED. B. DOMESTIC HOT WATER CIRCULATION PUMP PUP1P5A START /STOP AS SCHEDULED BY DDC SYSTEM. STEAM METER DDC CONNECTION A. PROVIDE AN ANALOG INPUT TO THE STEAM METER. UGHTING CONTROL DDC CONNECTION A. PROVIDE DIGITAL OUTPUTS TO THE LIGHTING CONTROL SYSTEM. (EIGHT LIGHTING PANELS WITH FOUR OUTPUTS EACH). DEL/_ CENTER. WA an swum J# 140799 -00 OM M311 i 140799 -00 9- 98 -M311 Cr: 1 ?ER!.F; Anti' Er. COW 08.15.06 • a rn a 1-1/2" LPC STEAM HEATING COIL (TYP) 4" - 151 CPP -PB 9-98 RENOVATION HC -3 3/4" j PUMP TRAP (TYP) PC 1 CPP -PA 1 4140799 -00 COMM • 1 Ills SOMA 1 6"-15i STM HEADER 010E 08.1506 a STEAM METER 5:I F&T TRAP LPC 1 1 3" 5" PRV -1 1300 LBS /15fl 3/4" 1 RV iBS /1 .61 1 H HH —1— iji ear HI ti_ SCALE: NONE • a LPC LPC LPS 1 CPP -PC 1 4 DIRT LEG & THERMODYNAMIC TRAP 250 LBS/HR LPC 4"VTR 3" SEE �j 5/509 -� CPP -PD SLEEVE (TYP) I I 3/4" STEAM SYSTEM DIAGRAM n 2 -1/2" -151 CONDENSATE RECEIVER CPP -1 B 1 t 1 1 p lAVEZAW • 3" U CONDENSATE PUMPS U °..3 F&T TRAP 1 MPS 2" DIRT LEG & THERMODYNAMIC TRAP 60 LBS /HR 2 1/2" PC DUPLEX PRESSURE POWERED CONDENSATE PUMP AND RECEIVER LOCATED IN PUMP ROOM 11J6 ON FIRST FLOOR THERMODYNAMIC TRAP 0 1 ACCEPTABIUTY SE COIGN AO/OR SPEOF1f RION 6 NPSOND IFFROVED OV 1-r 2 1 PC C 1- CONDENSATE RECENER 3/4 CPP -1A Ak PRV-3 50LBS/60/ 60 1 _ I I 1 l l e r- - -3" VENT 1" ow- PC CONDENSATE PUMPS OffE Virinto 11.90111101 LA 07.25.06 07.25.06 3/4" 1 CA MPS uEawaau. MASTER NEW DRAIN VALVE DIRT LEG & THERMODYNAMIC TRAP 3600 TITS/HR I ISSUED FOR I CONSTRUCTION PENTHOUSE 2ND FLOOR 1ST FLOOR C 4"1251 PSI 3" I PC STEAM SYSTEM DIAGRAM 9-98 RENOVATION BUILDING 998 LEGEND _• . 1 D4 GENERAL NOTES REFERENCE DRAWINGS 1M61, FIRST FLOOR FIVAC PIPING PLAN 1M62, FIRST FLOOR HVAC PIPING PLAN 1M63, FIRST FLOOR HVAC PIPING PLAN 2M61, SECOND FLOOR HVAC PIPING PLAN 2M62, SECOND FLOOR HVAC PIPING PLAN 2M63, SECOND FLOOR FIVAC PIPING PLAN P1M450, ENLARGED WEST PENTHOUSE PLAN P1 M451, ENLARGED EAST PENTHOUSE PLAN CONSTRUCTION NOTES 2" FROM BLDG 9-99 DUPLEX PRESSURE POWERED CONDENSATE PUMP AND RECEIVER LOCATED IN MECHANICAL ROOM 11V7 ON FIRST FLOOR ACP 1! E E R S 1601 !'ittl 1lrenue Sine 900 Seattle, Washington 96101 -1625 206 623 0717 Fax 206 624 3775 DEV: CENTER,WA • TO BOILER HOUSE CONDENSATE RETURN (PUMPED) CONDENSATE RETURN (GRAVITY) STEAM SUPPLY (MEDIUM PRESSURE) CONDENSATE, STEAM (LOW PRESSURE) STEAM TRAP 2 WAY CONTROL VALVE W /ELECTRICAL ACTUATOR PRESSURE REGULATING VALVE (SELF CONTAINED) PRESSURE RELIEF VALVE / SAFETY VALVE SWING CHECK VALVE WITH FLOW BALL VALVE, OPEN WYE STRAINER (WITH DRAIN VALVE) GLOBE VALVE, CLOSED GATE VALVE, OPEN LATERAL on MEVI ON 4140799 -00 ONO NOL M312 140799-00 9- 98 -M312 cr :; 1 , COMP MIL 08.15.06 a A 9-98 ROVAllON 4140799-00 COMPRESSED PLANT AIR, SEE FLOOR PLANS- COMIWO ALARM GONG 11.5011.1WI 011106 EXISTING DRY PIPE FIRE SPRINKLER ALARM VALVE ASSEMBLY TO REMAIN V .-77F PRESS SWITCH FASTING DRY PIPE FIRE SPRINKLER AIARM VALVE e - 3/4" EXTEND DRY SPRINKLER PIPING TO AREAS SUBJECT TO FREEZING, SEE FLOOR PLANS le QUICK DISCONNECT COUPLING (TOOL HOSE) 1 11 1 TO MECH 11V7 CONDENSATE 4c PUMP, SEE . 1 • M509) 4 0 1 -1 ‘ 1 PUMP PIT FLOOR END BALL VALVE 1 -1 3/4" r ALARM GONG • FLOAT SWITCH F PROVIDE NEW FLOW SWITCH, COORDINATE WIRING WITH ADT • se- -e• -• e. 1T1 ,T, ,T, ,T, ,T DRY SPRINKLER ALARM VALVE HOSE END BALL VALVE • TO AIR OURETS PENTHOUSE FIRE SPRINKLER DIAGRAM SCALE: NONE 1/2"A TO PNEUMATIC CONTROL AIR TO BE EXTENDED BY CONTROLS SUB-CONTRACTOR 3 p illIFEZAW• EXTEND DRY SPRINKLER PIPING TO AREAS SUBJECT TO FREEZING, SEE FLOOR PLANS ) • ALARM GONG-. FLOAT SWITCH dr 4 1 1 I f, LL I I fl 1 1 1 11 COORDINATE WIRING WM-I ADT PROVIDE NEW FLOW SWITCH, EXISTING DRY PIPE FIRE 1011- SPRINKLER ROOF ALARM VALVE 1 or -3/4" d915 TO CONDENSATE PUMP, SEE M509 COMPRESSED PLANT AIR DIAGRAM M SCALE: NONE PRESS SWITCH EXISTING DRY PIPE FIRE SPRINKLER ALARM VALVE ASSEMBLY TO REMAIN I f: 1 A 1 ACCEPTABILITY ms MEN 7= IuI COMPRESSED PtANT MR, SEE FLOOR PLANS (_ ALARM GONG 1/2"A TO PNEUMATIC CONTROL AIR TO BE EXTENDED BY CONTROLS SUB-CONTRACTOR A TO AIR OUTLETS PENTHOUSE DEPT. ONE APPRICIVID r -3/4" A 3/4" HOSE END ) 1-11 E--00 BALL VALVE MECH 11J6 07.25.06 0725.06 3 4" 10- -0s IN 0 4,8 I I T, I T, ,T, 4 ISSUED FOR CONSTRUCTION INAGRAPAS KL 9-98 RENOVATION BUILDING 9-98 MECHANICAL MASTER PENTHOUSE 2ND FLOOR 1ST FLOOR QUICK DISCONNECT COUPLING (TOOL HOSE) 90 PSI 1" FROM CENTRAL PLANT A -10-1 ROOF 2ND FLOOR 1ST FLOOR M t) ty‘ ei ACPFI GINEEis FMAN 1601 Rh Mom Sae 900 SeoWe, Washington 96101-1625 206 623 0717 Fez 206 624 3715 • 1 DEV • wawa Ream 41140799-00 M315 140799-00 9-98-11315 08.15.06 • *Ea P1M450 08.15.06 LEGEND FIRE DAMPER SMOKE DAMPER BACK DRAFT DAMPER P1M450 M504 TOILET EXHAUST MOTOR TEMPERATURE CONTROL PANEL MOTORIZED DAMPER TEMPERATURE SENSOR AIRFLOW & TEMPERATURE MEASURING DEVICE (ATMD) EXHAUST LOUVER 4' -0 "x5'_0 " VERIFY ALL EXISTING (E) DUCT AND PIPE SIZES AND LOCATIONS NOTED PRIOR TO FABRICATION OF NEW WORK CONDENSATE RETURN (PUMPED) 11> CONDENSATE, STEAM (LOW PRESSURE) LOW PRESSURE STEAM (15 PS1) CHILLED WATER SUPPLY CHILLED WATER RETURN POINT OF CONNECTION SMOKE DETECTOR 48x48 TRANSITION TO 42x45 (2 TYP) 40x32 DN TO 28x36 SOUND ATTENUATO 48/110 """'" GENERAL NOTES TEMPERATURE CONTROL PANEL 2 O 30 REFERENCE DRAWINGS M501, PENTHOUSE SECTION M504, PENTHOUSE SECTION cos, STEAM SYSTEM DETAILS M510A, MR FUWDLIN6 UNIT DETAILS INSTALL NEW AIR HANDLER UNITS, AHU -3 & AHU -4 PROVIDE NEW MOTOR, VFD DRIVE BY EC PROVIDE NEW 4'x6' OUTSIDE AR DAMPERS WITH ACTUATORS PROVIDE NEW 3'x8' RETURN AIR DAMPERS WITH ACTUATORS SEAL MIXED MR PLDIUM AROUND NR HANDLER UNITS AND GAP BETWEEN THEM 8 "CHWR 8 "CHWS SOUND ATTENUATOR FLEX 72/72 PROVIDE 1-1/4" COOLING COIL DRAIN 8 CLEAN EXHAUST AIR LOINER MESH SCREEN 9 NEW 24x18 DUCT B›.- REMOVE EXISTING OUTSIDE AIR DAMPER AND CAP OPENING SMOKE DETECTOR BY ELECTRICAL CONTRACTOR (TYPICAL) CONDENSATE PUMP TRAP PACKAGE, SEE 24x18 - DETAIL 5/509 1500 CFM () 5"LPS 3"LPC AIR ncM� SIDING 24 "x48 "DOOR P1M450 M501 1500 CFM 24x18 30 "x60"DOORS ENLARGED WEST PENTHOUSE HVAC PLAN 0.2:-> NEW LOW PRESSURE STEAM LINE 0.3:> INSULATE EXISTING CHILLED WATER D> PROVIDE SMOKE DAPPER R> INSTALL PUMP TRAP PACKAGE D PROVIDE 72x72 SOUND ATTENUATOR (60' LONG) _F d -- EXHAUST AIR LOUVERS 10'-- 0 "x5-0" EXHAUST AIR DAMPER MOTOR OPER 10'- 0 "x2' -6" MOTOR OPERATED RETURN AIR DAMPERS 3 0 3'-- 0 "x8' -0' (TYP k AIR t SMOKE DETECTOR O PENING IN FLOOR FOR RETURN AIR EXHAUST AIR DAMPER MOTOR OPER 10'- 0x2' -6' P1M450 M504 1 "COMP AIR lir> INSTALL row MEASURING STATION 1" PFG15 FIBERGLASS W /NEOPRENE COATING, 1 CEMENTED TO EAST WALL OF PLENUM P1M450 M504 EXHAUST AIR LOUVER ® PROVIDE 48x96x110 PLENUM WITH 48x48 TRANSITION TO (E) 42x45 DUCTS NEAR FLOOR I!:: PROVIDE 40x32 DN, TRANSITION TO (E)28x36 DUCT NEAR FLOOR ® PROVIDE 96x96 SOUND ATTENUATOR (60' LONG) VFD FOR RETURN FANS PIPE GUIDE Pr> PROVIDE NEW FIRE DAMPER PROVIDE NEW MOTORIZED DAMPER VI> PROVIDE TEMPERATURE SENSOR FOR PENTHOUSE RS> PROVIDE NEW STEAM PRESSURE REDUCING STATION W> PROVIDE STEAM METER PROVIDE SWAM RELIEF VENT AND TERMINATE 3FT ABOVE PENTHOUSE ROOF 9 -98 RENOVATION BUILDING 9 -98.P1 MECHANICAL MASTER coc. F - M/5 - s PIPE GUIDE - 6 "--125 PSI MPS STEAM METER, SEE DETAIL 7/509 STEAM PRV, SEE DETAIL 1/509 - ENLARGED WEST PENTHOUSE PLAN 8"CHWR 8 "CHWS KEY PLAN SOLE: NC NE t 6" STEAM STEAM REUEF VENT 1 SEE DETAIL 8/509 • • • • • e • NON AIR TIGHT SIDING EXHAUST AIR DUCT (OVER) 10'-- 0 "X2' -6" VFD FOR RETURN FANS AIR TIGHT SIDIND, SEE NOTE THIS DWG P1 M4511 M504 SUPPORT ANGLE FOR INCLINED PLENUM WALL P1M451 M504 EXHAUST AIR LOUVER PLENUM PIPE GUIDE EXHAUST AIR DAMPER MOTOR OPER 10'- 0 "x2' -6" MOTOR OPERATED RETURN AIR DAMPERS 3 0 3'- 0 "x8' -0" (TYP) CURB ALL AROUND EXHAUST AIR DAMPER MOTOR OPER 10 0x2' -6" OPP. HAND P1M451 LOW PRESSURE PLENUM WALL 24"x48 DOOR J EXISTING 1 CURB 1 -1 /2"LPC DN 3"LPC DN 24x18 ' 1500 CFM 8 "CHWR 8 "CHWS ENLARGED EAST PENTHOUSE HVAC PLAN g) LAPAPEFAW* 30"Wx24"H EXHAUST LOUVER MECH ROOM EXHAUST 18 "0 SOUND ATTENUATOR 72x72x60 SOUND ATTENUATOR 96x96x60 PROVIDE SMOKE DAMPER INSTALL PUMP TRAP PACE PROVIDE 72c72 SOUND ATTENUATOR (60' LONG) PROVIDE 48x96x110 PLENUM WITH 48x48 1RANSIfION TO (E) 42c45 DUCT NEAR FLOOR 0.> PROVIDE 4O02 ON. TRANSITION TO (E)28x36 DUCT NEAR FLOOR ta> PROVIDE 96x96 SOUND ATTENUATOR (60' LONG) 36/42 TRANSITION DN TO (E)28/36 AT FLOOR TOILET EXHAUST VERIFY ALL EXISTING (E) DUCT AND PIPE SIZES AND LOCATIONS NOTED PRIOR TO FABRICATION OF NEW WORK INSTALL FLOW MEASURING STATION igt>s NEW LOUVER BY GC PC=P PROVIDE NEW FIRE DAMPER W>. PROVIDE NEW MOTORIZED DAMPER � PROVIDE ,o+PERan saves FOR PENTHOUSE EXISTING 24X16 GRILLE. ENLARGED EAST PENTHOUSE PLAN 9-98 RENOVATION BUILDING 998.P1 H AIRFLOW & TEMPERATURE MEASURING DEVICE (ATMD) GENERAL NOTES r1 > TEMPERATURE CONTROL PANEL. 2 0 30 "x36 REFERENCE DRAWINGS M312, PLUMBING DIAGRAM M501, PENTHOUSE SECTION M504, PENTHOUSE SECTIONS 11510, AIR HANDLING UNIT DETAILS CONSTRUCTION NOTES EXTEND EXISTING CHILLED WATER SUPPLY AND RETURN INSTALL NEW AIR HANDLER UNITS, AFIU —t do AHU -2 PROVIDE NEW BLENDER IN MIXING AIR PLENUM PROVIDE NEW MOTOR, VFD DRIVE BY EC LEGEND PC— LPS— c:Hws —cHws mo KEY PLAN sou: NONE CONDENSATE RETURN (PUMPED) CONDENSATE, STEAM (LOW PRESSURE) LOW PRESSURE STEAM (15 PSI) CHILLED WATER SUPPLY CHILLED WATER RETURN POINT OF CONNECTION SMOKE DETECTOR MOTOR TEMPERATURE CONTROL PANEL FIRE DAMPER SMOKE DAMPER BACK DRAFT DAMPER MOTORIZED DAMPER Q TEMPERATURE SENSOR E:: PROVIDE NEW 4'x6' OUTSIDE AIR DAMPERS WITH ACTUATORS 6 PROVIDE NEW 3'x8' RETURN AIR DAMPERS WITH ACTUATORS SEAL MIXED AIR PLENUM AROUND AIR HANDLER UNITS AND GAP BETWEEN THEM 8 PROVIDE 1 -1/4" COOLING COIL DRAIN y CLEAN EXHAUST AIR LOUVER MESH SCREEN D> NEW 24x18 DUCT REMOVE EXISTING OUTSIDE MR DAMPER AND CAP OPENING lir> SMOKE DETECTOR BY ELECTRICAL CONTRACTOR (TYPICAL) PROVIDE NEW LOW PRESSURE STEAM UNE INSULATE EXISTING CHILLED WATER BETWEEN TWO PENTHOUSES PROVIDE NEW EXHAUST FANS & CONNECT TO EXISTING DUCTWORK FOR EF -2, TO NEW DUCTWORK FOR EF -3 08.15.06 • • • • A 9-98 RENOWiTION 4140799-00 COFTWN u. SOR1RA RETURN F FLEX C0117 - HP MOTOR OPERATED RETURN AIR DAMPER S-0"x8 O" OP' 9f EGRAL STEEL BASE I I 5 .<11 MOTOR OPERATED RETURN AIR D1PER 3 INCLINED LOW I 1 WALL 5 PLEII1UM 5 -.461 MOTOR OPERATED RETURN AIR DAMPER S-0"x8 ( 1111 An ki RETURN 1 II* INTEGRAL STEEL BASE a - C4 DOE 08.15.06 EXHAUST GRILLE WITH MANUAL & FIRE DAMPER 1500 CFM—' EXHAUST AIR DUCT 2'-6"x10 EXH AIR DAMPER LOW PRESSURE PLENUM WALL SUSPENDED CEILING SECTION SCALE: 1/4"=1'-0" WEST PENTHOUSE AS SHOWN EAST PENTHOUSE OPP. HAND A P1M4*501 t? ) LAPPISPWIAK g • NON-AIR TIGHT SIDING EXHAUST AIR LOUVERS 24"x24" ACCESS DOOR AIR TIGHT SIDING PENTHOUSE FIR EL 43'-10 1/2" 24x18 DUCT - WITH MOTORIZED AIR DAMPER ACCEPTABlUlY DNS Mal NO/OR SPIZIFINION B AWNED BY CEPT. ISSUED FOR CONSTRUCTION COMAN MEM IL SWUM 4110N112 suE 07.25.06 07.25.06 MECHAM% MASTER PENTHOUSE SECTION 9-98 RENO'VADON BUILDING 9-98 1601 rith karma Sole CO 9 Seattle, ltoshinslon 98101-1625 206 623 0717 For 206 624 3715 LEGEND GENERAL NOTES REFERENCE DRAWINGS P1M450, ENLARGED WEST PENTHOUSE PLAN P111451, ENLARGED EAST PENTHOUSE PLAN CONSTRUCTION NOTES KEEP EXISTING RETURN FAN PROVIDE NEW SEISMIC RESTRAIN FOR EXISTING RETURN FANS PROVIDE NEW 7.5 HP INVERTER DUTY MOTOR PROVIDE NEW FLEXIBLE CONNECTION PROVIDE NEW RETURN AIR DAMPERS AND NEW EXHAUST DAMPERS PROVIDE NEW 24X18 DUCT WITH MOTORIZED DAMPER AND FIRE DAMPER Mbwoligt3 CLIVIENi REVISION JI140799 SHEET MEI NO. 140799-00 M501 COUP lItk 08.15.06 • • A 9 -90 RENOIiAT10N F • RY PIPE VALVE ASSEMBLY 4140799 -00 8r WPR>?WED OAE o fMIW M.90A1R% • 4 0&15x06 1 OUTSIDE AIR INTAKE et • SECTION 01....BOE /Na• • A PiM260�M�2 et r-OUTSIDE AIR INTAKE ca2N us .SI C 6 M OIIEn • COMM 1tr90T19111 07.25.06 07.25.06 DRY PIPE VALVE ASSEMBLY uE VAsmR ISSUED FOR CONSTRUCTION I PENTHOUSE FLOOR q 1601 fWth knave Sine 900 Seat*, Wadi)** 96101 -1625 206 623 0717 Fax 206 624 3775 PENTHOUSE SECTIONS 9-98 RENOVATION BUILDING 9.98 t • CEV. CENlER,WA LEGEND • F ---- -- FIRE SPRINKLER PIPE POINT OF CONNECTION ® AUTOMATIC SPRINKLER RISER GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES MODIFY WET PIPE SPRINKLER SYSTEM FOR COORDINATION WITH NEW AIR HANDUNG UNIT, DUCTWORK, FANS & PIPING EXTEND DRY PIPE SPRINKLER PIPING TO UNHEATED AREAS OF PENTHOUSE INCLUDING AIR HANDLER INTAKE PLENUMS frt an RIEWSION 4140799 -00 JOB RD. DUG Nat M502 140199 -00 9- 98 -It502 I E M• :r- 08.15.06 1 OEM motto PPPRGAtt APPROVED COMP DO. • i t • PPE SUE OOIT W C A UP W 1-1/2 1/r 1/r rTO r 3/4 1/4 SIN A 9-98 RENOVATION EQUIPMENT KO FRAWC awMR et NOE IRO r 6 WATER nom sat Waal 91K OS NNW SERE PPE WNW SCALE: NONE 1 ELEVATION SLACK CABLE FOR ATION ISOLATED EQUIPMENT (TYP.) PLAN fir ELEVATION SUSPENDED EQUIPMENT SEISMIC BRACING DETAIL ail SCALE: NONE J5O3 f ORXE SEM POE CONE OPXOC SEE swan • • Rom 1. SEE SNOW WU SO4 1BL FOR WOOL NUM SPOOR BRIDE. WU SIDE t 0010' =10 AMMO 510CFI PE. POE MUER 1100 CPC O O. WE A 1N10 OWP /r E 1W • BENI lam' WS MI WOE WOW aim wow or mom 4140799 -00 comma QUIP. FRAME OR SUPPORT POINT NEQUIP. VAIN TOP SUPPORT POINTS SUIC CABLE BRACE (DP.) j5503 SCAM NONE II- 08.1506 WORM CAOIE tOXE 1010E 1D COW IEW IOW DOE war • - I OWONfi! BRACE r SCALE: NONE I' ROD AO IEROJ! RINGER IWO EOM MIMEO ONO ORE SEE RO O WEE FOR WIWI MOMS, MEW O RM WV SUE AO WNW= MOM OiP. TYPICAL CABLE TRANSVERSE TYPICAL CABLE Saw MOE w 3 N1901 SIC COPS SEE I O1 - 1 • `1f OM NIL 16001- WNW vr On 7 ma) SoF NUS F ONE DiIM! COMMON TO Wpm= m SINIIOOP& WINER 03.1 era) Ca WC romil mE. OWE OFEOWSIDEOF OWE (SNOW 00110 (OF SOUS & SOWS EOM 11,01 /16tE SIDE BRACING FOR RECTANGULAR DUCTS SCALE: NONE 1 MEOW A StNOR116 Sng1OOP& Ft1O01 OW E LOWNONL WAX ONE UM SCE Cf tan OM 0011E13 CENTER BRACING FOR RECTANGULAR DUCTS (� NVE.1MIEtE 9AIl OS 111/31 E S SEE M E. 04WMBOorMIER ORE set X7M EWMsuer ama• EE No Is VS Et ist sow tot wsio) MK= CEP 1601 di NO ISSEIL NOE 1101 SOMME 1 > °6°BZ WE EMU UN= tAA COMM N i�l■1Bt EMI t r+�r me E. SE SE= Unlit lIR IMO7ME IR MICE NNW EIESEEK # 1IESIONE. ! >•A OF l Ali 2 TIAN 1 , STRUT BRACING FOR BRACE AT PIPE HANGER ( LONGITUDINAL BRACE (ii PIPE TRAPEZE , Lii503 SCALE: NONE • ,0 I IG OIL 1• (SA III 1 k V, IN. CAPE OWICE ' NIOBI vas OF in 11EISEllE MBE 2 mil r SIMI SCALE: NONE APWAVA/4"• SORROW SITHOWL REIMER EIZItO (OF ANCtE 91E NI OWEN SEE SCALE: NONE CA 1E OWE LOWNWL ONE EACN SIDE SW O WL SEE SUM SEE sumw SUMO MOM MK FPM, NINIR FIG 9-3 OR 9-2 OR 9-4 1 2 UN VAX CABLE SIDE BRACING FOR RECTANGULAR DUCTS (.3- ,EA503 SCALE: NONE 2 VAX CABLE CENTER BRACING FOR RECTANGULAR DUCTS 6 • \w1 • 104 • INK SR EMIE NO NIECE MEMO owir w N ow i • WWI NW w IOW 1. BEE MOEl PRIX NICE 901a 1111 78 I•IR IE 18pBE 11111111111. en ix A IA IIRI O� WI ( OF MAE IROWISE aatE TRW CABLE BRACING FOR tt PIPE TRAPEZE ( :15 ACCEPTABIUTY �S mires ef =WW1 10 SWUM =CUR F>E1Net RESINS NUL OR 0-4 SEE S11OIN 21511C WWII YAWL On 9-2 M503 Ina RE situ OEM (L e NICER EL SW Cf WT. ONE MEM acoalb DEMO COW= TO SWUM STFpcINK IMMER litHWRSE BWICE • 2W1 1 1■1 1 PPE NNOR ROD COP WNQOOI Mt AA E MOM MOP 4Y3/11' SCALE: NONE s i VMS (OF AWE NOTE: 1. SEE SIOWN EWO1: saws PBIE FOR Waft MEW. WSOIML BRIE$ WIT RE Fr MECUM 10 SIWORT O MOM MECHANICAL MASTER MOORS WE TOR EXIIPIE WWII KO SERI0N. WOOERS ANTE FW11 Val WEN V MEOW NW WORN WINN Pet U p 11111 3 WSW NO ICE Slaw 1INT WS 111EIDE FOAM 1/4' 1 L1WOiR IR OMR WOOER OF BOIL DORM WE WAXER I FOR INFORMATION I ONLY SCAM C 111) f T OON. DEOX 1 X MOW (SFE FUN) r (150 I / l - MOD, of NEMOI. SEISMIC BRACING DETAILS 9-98 RENOVATION BUILDING 9-98 COMM 10 WINER 1/r 1' - 24' (3.18 WO (25.4 - 010 LW) ADD WRT. AMENS FROM SCHEDULE MEN t Is � TWIN Wu1. WIG1 I �`.• TRANSVERSE • -V 2 LUX SCE 0M BRACE ONE SIDE OF 11311 RATE o NNEWOR WE A 11N10 3111/4' (75w01.4nr) 4 OOI (11� TIP. WNW 11/OBL SCOWL SEE MBE FOR WE FOR BOLT SUE SEE 7w( �1,�5p3 SCALE: NONE 1- 5)"X1 -5/8'x 14 l 14 OA. (41.1e41.3212.0 501) NICIE. 1/2' (12.7 181) (MACHINE BOLT TO 1RAPUE:; /10 SELF TAPPR10 slcaEW TO DUCT. SIDE BRACING FOR RECTANGULAR DUCTS SCALE: NONE 0 LOWO OWE MACE NOE u6D61 was mom 11N114' Cr RANGER E1tlIClIB (Elm: W5L1 OR 6/51.1 IMF TYPICAL RIGID TRANSVERSE ALTERNATE RIGID BRACE AT PIPE HANGER ( TRANSVERE 2u260.1z,3 155°3 1 SIROCRI N. 8001 NUE PER SHOW WE BUM PER SUE= WE LUMP & \ 10E03 RC. 910 SUM. MVO TYPICAL SPRINKLER TYPICAL SPRINKLER RELOCATION ASSMEBLY SEISMIC BRACE ASSMEBLY riet SCALE: NONE ' d SCALE NONE KEV. CEMTER,WA All (Q r milt aaaf doe applicable codes sad desks sbodnds related is seismic protection of RVAC compoaeats and "stifled in design ofs micpaedioesaed midi berg dream shall be emposside foremotionofdee work herds. Shag be mood* for the °U sod fled inspection IfflIA seismic pmtdioss mired by appicable codes. CURPS/ff AMON 4140799 -00 SHEET WARM /WNW *MAD SPIT STUB RANGER '08 H0` 140799 -00 OM IRMO aw 1-5/r 2 NU 1 WNIT Somme OWCE FOR lltl SOE PPE UP 11 WU alma SWIM PPE OAP 1-W MOE MOM RN SWORE FIE 1'SCI40 A V-C 1T-r 11/4'SW40 1 SDI 40 r -vto -v r- r A1� -4'. W-4' 10111 M503 9- 98 —M503 COMP NO. 08.15.06 • • • • • TOILET EXHAUST LOUVER NON- AIR TIGHT SIDING LOW PRESSURE PLENUM CEILING EXHAUST AIR DUCT AIR TIGHT SIDING MR INTAKE HOOD OUTSIDE MR FLOW MEASURING STATION A � P1M450�M504 AHU -2 INTAKE DUCT BEYOND Si�E BASE PROVIDE NEW ISOLATION RESTRAK[TS CURB BALL AROUND SL +' : TO F1R �HAUSf AIR LOUVER OW E'RESSURE PLENL M CEIUNG EAST PENTHOUSE AS SHOWN WEST PENTHOUSE OPP. HAND SECTION SCALE: 1/4 RETURN AIR DAMPERS 3 3 , -0 .. -O . - EAST PENTHOUSE AS SHOWN WEST PENTHOUSE OPP. HAND SECTION 32/36 . SECURITY GRILL (TYP 5) ACCESS DOOR MP 5) EXHAUST AIR DAMPER, 10'x2' -6" PLENUM WALL ATTACH 96 "x48 "x36" AIR BLENDER TO CASING © REMOVE ALL FOUR EXISTING OUTSIDE AIR DAMPERS. PROVIDE 3 NEW DAMPERS SAME SIZE AS PREVIOUS. SHEET METAL TO BLOCK ONE OPENING. F1::::;a SEAL MIXED AIR PLENUM BETWEEN NEW AHU & PLENUM CEIUNG LEGEND CHWS CHWR --- - LPS - LPC GENERAL NOTES CHILLED WATER SUPPLY CHILLED WATER RETURN STEAM SUPPLY (LOW PRESS,0 --15 PSG) CONDENSATE, STEAM (LOW PRESSURE) POINT OF CONNECTION REFERENCE DRAWINGS P1M450, ENLARGED WEST PENTHOUSE PLAN P1M451, ENLARGED EAST PENTHOUSE PLAN CONSTRUCTION NOTES SEE DWG P1 M3 FOR NEW FLOOR DRAIN ti INSTALL NEW AHUS ON 4" HIGH x 12 WIDE CONCRETE CURB & ANCHOR AHUS TO EXISTING SLAB FY:::: PROVIDE NEW ISOLATION RESTRAINTS 8 PROVIDE NEW EXHAUST DAMPER 9 PROVIDE NEW MOTOR Iw›. PROVIDE NEW AIRFLOW MONITORING STATION CONNECT 28 "0 TO EXISTING 32x36 RISER Ig>.- CLEAN DUCT RISER w:=. PROVIDE NEW RETURN AIR DAMPERS CLEAN OUTSIDE AIR LOUVER MESH SCREEN 07.25.06 CURROR s J #140799 -00 A 08.15.06 WEI M504 • • • • z WOOKK Y HOT DUCT UM (PER PUNS) HOT DUCT INLET SIZE 0-170 4 171-340 6 341 -700 8 701 --1000 10 - 1001 -1400 12 1401 --2000 14 s!u RECTANGULAR TO ROUND DUCT TRANSITION FLEXIBLE DUCT SEE PLANS OR DIFFUSER SCHEDULE FOR SIZES. SEE SPECIFICATIONS FOR MAXIMUM LENGTH PROVIDE 1/4" BEAD AROUND COLLAR FOR CLAMP CATCH SMACNA APPROVED CLAMP NOTE: 1. FLEXIBLE DUCT TO DIFFUSERS SHALL NOT BE USED ABOVE NON - REMOVALBE HARD CEIUNGS. USE RIGID DUCT CONNECTIONS. 2. ACOUSTIC LINING ONLY REQUIRED ELEVATION AT CONFERENCE ROOMS. MAIN TRUNK DUCTS AIR FLOW COLD SUPPLY DUCT, SEE FLOOR PLANS TYPICAL RESTRICTED CEILING HEIGHT DIFFUSER CONNECTION (i SCALE: NONE STRAIGHT GALV INSULATED ROUND DUCT, MIN DISTANCE OF 3 TIMES BOX INLET SIZE SHEET METAL TRANSITION AS REQUIRED, TYP. CONTROL BOX (TYPICAL) DUAL DUCT VAV TERMINAL UNIT (TYPICAL) — NOTE: FOR COLD DUCT SIZING, REFER DUAL -DUCT SCHEDULE ON SHEET M2C. FOR HOT DUCT SIZING REFER TO CHART BELOW. 9-98 RENO/ARON 4 PLAN J1140799 -00 0 COMMA HOT SUPPLY DUCT, SEE FLOOR PLANS SQUARE OR ROUND DIFFUSER NECK. REFER TO DRAWINGS/ SPECIFICATIONS FOR TYPE AND SIZES. DIFFUSER BOOT W/ 1" ACOUSTIC LINING MOUNTING RODS UP TO STRUCTURE W/ SPRING ISOLATORS _._ - - -t PER SPECIFICATIONS DUAL DUCT TERMINAL UNIT DETAIL (5 1 SUM NONE et /M OS DIFFUSER NECK SIZE 1/2 DIFFUSER NECK SIZE ALL SIDES STRAP HANGER WHERE REQUIRED DIFFUSER BOOT W/ 1" FIBER -FREE ACOUSTIC LINING SOIURk e ■- MINIMUM 1/2" DIFFUSER NECK SIZE PLUS 2" CEILING - DIFFUSER REFER TO DRAWINGS/ SPECIFICATIONS FOR TYPE AND SIZE dIA505 45 DUCT TAKE -OFF FITTING FLEX DUCT IF NEEDED, TYP. MINIMUM 24" SERVICE CLEARANCE, OR MORE AS REQUIRED PER LOCAL CODES, FOR EACH SIDE WITH CONTROL PANEL MIN 12" CLEARANCE FOR SIDE WITH NO CONTROL PANEL LOW VELOCITY SUPPLY -AIR DUCT, SEE FLOOR PLANS MINIMUM 3'--0" TO FIRST BRANCH OR ELBOW ■t i5C/5 DUE 0&15106 FLEXIBLE DUCT PROVIDE 1/4" BEAD AROUND COLLAR FOR CLAMP CATCH SMACNA APPROVED CLAMP NOTE: 1. FLEXIBLE DUCT TO DIFFUSERS SHALL NOT BE USED ABOVE NON- REMOVABLE HARD CEILINGS. USE RIGID DUCT CONNECTIONS. 2. ACOUSTIC LINING ONLY REQUIRED AT CONFERENCE ROOMS. TYPICAL DIFFUSER CONNECTION (-2 &A505 SCALE: NONE THE FOLLOWING DUCT FITTINGS ARE CONSIDERED ACCEPTABLE. THE CONTRACTOR SHALT.. OBTAIN ENGINEER'S APPROVAL FOR OTHER FITTINGS PRIOR TO FABRICATION. ONLY FITTINGS WITH EQUAL OR LOWER PRESSURE DROP WILL BE CONSIDERED. DUCT ELBOWS TRANSMoN DIFFUSER NECK SIZE +2 BOTH SIDES R =1 /2W DUCTS W/ AIR VELOCITY UNDER 1,500 FPM R =W DUCTS W/ AIR VELOCITY OVER 1,500 FPM AND ALL DUCTS UPSTREAM OF TERMINAL UNITS 12x12" ACCESS PANEL ON BOTTOM OF DUCT UPSTREAM OF TURNING VANES. REQUIRED FOR RETURN AND EXHAUST DUCTS TURNING VANES CHANGE OF DUCT SIZE ooNICAu. SPIN-IN OR TwwsMaN TO CONNECTION END TAP SIZE AT LEAST 542 GREATER THAN AREA OF SMALLER DUCT PLAN ELEVATION SQUARE OR ROUND DIFFUSER NECK. REFER TO DRAWINGS/ SPECIFICATIONS FOR TYPE AND SIZES. DIFFUSER BOOT W/ 1 ACOUSTIC LINING DIFFUSER STRAP HANGER WHERE REQUIRED DIFFUSER BOOT W/ 1" FIBER -FREE ACOUSTIC LINING DIMENSION TO SUIT CEILING PLENUM. MINIMUM TO BE DUCT CONNECTION SIZE +2 ". SHEETMETAL BAFFLE INSIDE CEILING DIFFUSER DIFFUSER NECK SIZE REFER TO DRAWINGS/ SPECIFICATIONS FOR TYPE AND SIZE OFFSETS NOTE OFFSETS (TO AVOID OBSTRUCTIONS) ARE REQUIRED BUT ARE NOT NECESSARILY SHOWN ON THE PLANS. MAX. 15' 45' OR 90' RADIUS ELBOWS OBTAIN PRIOR APPROVAL FOR ALL RETURN & EXHAUST LOCATIONS TURNING VANES ACCESS PANEL (TYPICAL REQUIRED FOR RETURN & EXHAUST DUCTS T LESS THAN TWICE THE DUCT AREA DUCT FITTING REQUIREMENTS SCALE: NONE FLEXIBLE DUCT 11111 flfrff STRAP HANGER 8" MINIMUM INSIDE RADIUS PROVIDE 1/4" BEAD BEAD AROUND COLLAR FOR CLAMP CATCH SMACNA APPROVED CLAMP EARTHQUAKE SUPPORT WIRES WHERE REQUIRED NOTE: DIRECT CONNECTION OF FLEXIBLE DUCT TO DIFFUSER (WITHOUT DIFFUSER PLENUM) WILL BE ALLOWED ONLY WHEN SUFFICIENT VERTICAL CLEARANCE IS AVAILABLE TO MEET THE REQUIREMENTS SHOWN. TYPICAL DIRECT DIFFUSER CONNECTION n dIp05 SCALE: NONE BRANCH DUCT TAKEOFFS W/ MINIMUM PRESSURE DROP 11111r' i 45 ROUND OR RECTANGULAR 1 D =1/2W, BUT NOT MORE THAN 12" ---I w I (1/3W OK IF UNDER 3,000 FPM) - -1WI -- R=1/2W DUCTS W/ AIR VELOCITY UNDER 1,500 FPM R =W DUCTS W/ AIR VELOCIIY OVER 1,500 FPM AND ALL DUCTS UPSTREAM OF TERMINAL UNITS p aZI EI21 g d i ■ 45°5 n OK ONLY UNDER 1,500 FPM OK ONLY UNDER 1,500 FPM RECTANGULAR DUCT CONICAL SPIN -IN ROUND DUCT RUNOUT TO SINGLE DIFFUSER OR GRILLE ONLY ACCESS PANEL AIR EXTRACTOR ADJUSTABLE FROM OUTSIDE DUCTWORK. OBTAIN PRIOR APPROVAL FOR ALL RETURN AND EXH. LOCATIONS NXEPTABUIY pis OM= JVIDAR s1I OEM OM for ` 12" MINIMUM STRAIGHT VERTICAL DUCT ADAPTER WHEN REQUIRED DIFFUSER REFER TO DRAWINGS, SCHEDULES SPECIFICATIONS FOR TYPE AND SIZE ISSUED FOR CONSTRUCTION I OMAN OURS penchtb mime 07.25.06 07.206 uEaurICIu_ MASTER CONICAL SPIN -IN (MIN. 2" LARGER) a� NOTE: DO NOT UTILIZE FLEXIBLE DUCT IF NOT INDICATED ON PLANS. PROVIDE SHEEIMETAL DUCT, RECTANGULAR IF NEEDED FOR SPACE CONSTRAINTS TYPICAL CONNECTING DUCT FOR DIFFUSERS AND GRILLES (�1 SCALE: NONE tk•knufriltet AFC)F FMAN iGiNEEKS 1601 FM Mime Sole 900 Seattle, WaShinglon 96101 -1625 206 623 0717 Fox 206 624 3775 HVAC DETAILS 9-98 RENOVATION BUILDING 998 r- TRUNK DUCT NOT LESS THAN ONE STRAP HANGER FOR EACH FLEX DUCT OW CENTER,WA an ANNE N J4140799 -00 JOB NO. 0110 NO. (3) ACCEPTABLE ROUND DUCT TAKE -OFFS PROVIDE A VOLUME A VOLUME DAMPER FOR EVERY DIFFUSER AND GRILLE. LOCATE DAMPER AS FAR AS PRACTICAL, AND WITH NOT LESS THAN 6 UNEAR FEET OF DUCT, FROM DIFFUSER OR GRILLE. LOCATE DAMPERS ON RECORD DRAWINGS AND COORDINATE WITH AIR BALANCER 6 FOOT MINIMUM, 8 FOOT MAXIMUM LENGTH AND 180' MAXIMUM CUMULATIVE CHANGE OF DIRECTION FOR FLEX DUCT. PROVIDE AT LEAST 90" CHANGE OF DIRECTION WHERE POSSIBLE FOR ACOUSTICAL CONSIDERATION DIFFUSER OR GRILLE (TYP). REFER TO ACCEPTABLE CONNECTION DETAILS SIEEE M505 140799 -00 9-98-M505 • 1 3 COMP NG. 08.15.06 c or c • 1/4" WIRE MESH SCREENED OPENING SCALE: NONE CEILING • " NOTES: 1. RETURN AIR BOOT SHALL BE CONSTRUCTED OF SHEET METAL WITH 1" RIGID FIBER -FREE SOUND LINING. DUCT DIMENSIONS SHALL EQUAL NOMINAL GRILLE DIMENSIONS. 2. DIMENSION "L" SHALL BE 2' -0" MINIMUM, OR MORE AS REQUIRED TO PREVENT "LINE OF SIGHT" NOISE PATH. DIMENSION "1" CAN BE MEASURED FROM EITHER LEG OF BOOT. 3. PAINT DUCT EXTERIOR WITH PAINT SELECTED BY ARCHITECT. TYPICAL RETURN /TRANSFER GRILLE W /BOOT n dkj506 12" UGHT CLEARANCE 62x16 42x16 COMPUTER ROOM COOLING UNIT 1 { - SUPPORT DUCT BOOT FROM STRUCTURE WITH STRAPS OR HANGERS i FACTORY RETURN 1.----NR GRILLE "W" COMPUTER ROOM COOLING UNIT DUCTING rAi SCALE: NONE WALL MOUNTED TRANSFER GRILLE, MOUNT BOTTOM OF GRILLE BETWEEN 9' -6" AFF AND 10' -0" AFF • - v VOLUME DAMPER ROUND DIFFUSER BEAM CLAMP W /RETAINING CUP, PER SMACNA DUCT CONSTRUCTION STD, FIGURE 4 -2 :i: SLOT DIFFUSER MOUNTING DETAIL SCALE: NONE CUSHION CHAMBER LENGTH EQUAL - TO BRANCH DUCT DIAMETER 1 //\/ ROUND BRANCH DUCT J ROUND DIFFUSER DETAIL SCALE: NONE THREADED ROD, 2 PER DIFFUSER 36" LONG CHANNEL. ATTACH TO SLOT DIFFUSER IN 4 PLACES OVAL INLET ` LAY -IN CEIUNG SLOT DIFFUSER AND PLENUM. MOUNT BOTTOM AT 9'6 "AFf WHERE NEAR CEIUNG TILE. MOUNT AS HIGH AS POSSIBLE WHERE IN AREAS WITHOUT CEIUNG BLANK OFF END OF DUCT ROUND DUCT DROP CONFIRM EXACT ELEVATION FROM ARCHITECTURAL DWG WHERE VISIBLE FROM BELOW, GALV SHT MTL DUCTWORK & SLOT DIFFUSER SHALL BE PAINTED AS PER ARCHITECT COLOR SELECTION. WHERE ABOVE CEIUNG, & NOT VISIBLE FROM BELOW, DUCTWORK SHALL BE EXTERNALLY INSULATED zLm506 • ISSUED FOR CONSTRUCTION I LEauMCU wear NON SECURE SIDE SECURE SIDE SCALE: NONE 11e) qN 1601 Nth ?moue sae 900 Sedge, 1bsh:glon 98101 -1625 206 623 0717 Fax 206 624 3775 9-98 RENOVATION BUILDING 998 • 16/36 34 DEV. CENTER,WA ## INSPECTION WINDOW 10/6 MANBAR DETAIL n JOB le_ OM ROL 140799 -00 MAN BAR BMAC STD 83 -1 9 -98 -11506 'COMP IQ. r • 9-98 tEaNArON PROTECTION SADDLE OVERLAPPING GALVANIZED SHEET METAL PROTECTION SHIELD INSULATION INSERTED IN SADDLE CAVRY SCALE: NONE CEILING CONDENSATE DRAIN UNE (INSULATED) - CW FOR HUMIDIFIER • STEAM SHUT —OFF VALVE DEATIL w508 DETAIL 'A' HOT PIPE " DIAMETER AND LARGER (60° F & HIGHER) PIPE HANGERS — INSULATED PIPE DETAIL ( 2 1 SCALE: NONE AUTOMATIC AIR VENT PETES PLUG (TYP) - 1 LOW POINT DRAIN W/ HOSE CONNECTION FLOOR MOUNTED CHILLED WATER COMPUTER ROOM COOLING UNIT PIPING DIAGRAM SCALE: NONE 41140799 -00 HANGER ROD W/ JAM NUT CLEVIS HANGER PIPE INSULATION CUT TO FIT AROUND PROTECTION SADDLE OVERLAPPING GALVANIZED SHEET METAL PROTECTION SHIELD DOUBLE THICKNESS JACKET BOTTOM • 6Y COFIWN TO PENTHOUSE THREAD -O -LET 2" BY -PASS F -- I 4 CH1NR CHWS - STRAINER COIL RUNOUT DRAIN W/ HOSE CONNECTION. LOCATE 0 LOW POINT CONNECTION OF RUNOUT PIPING COMPUTER ROOM COOUNG UNIT /NOM MSOIURA 001 08`15.06 HANGER ROD W/ JAM NUT CLEVIS HANGER PIPE INSULATION - UPPER HALF OF PIPE HIGH DENSITY INSULATION INSERT - LOWER HALF OF PIPE DETAIL 'B' HOT PIPE UNDER 4" DIAMETER COLD PIPE ALL SIZES BALL VALVE 011 1 d A5°13 d■ a568 et • DRAIN PANS (TYP.) TO AUXILARY DRAIN PAN THREADED CAP FOR PRIMING & CLEANOUT (TYP) " 3- 1r ¢ D4 j 1 SCALE: NONE PROVIDE OVERFLOW CONDENSATE DRAIN WITH TRAP WHERE CONNECTION IS PROVIDED WITH UNIT, PROVIDE DRAIN CONNECTION TO SEPARATE DRAIN PAN (WITHOUT TRAP) OTHERWISE INDIRECT DRAIN TO COLLECTOR PIPE OR APPROVED RECEPTOR, ONE PIPE SIZE LARGER THAN CONNECTION SIZE NOTES: 1. SLOPE ALL DRAIN PIPING PER CODE, BUT NEVER LESS THAN 1%. ?LiolizerAv4) • M 3 � 1 1 111 1>4 I DRAIN PAN PROVIDE GRAVITY CONDENSATE M') DRAIN WITH TRAP OR PUMPED CONDENSATE DRAIN AS APPLICABLE FOR UNIT. CHILLED WATER COIL PIPING DIAGRAM( AHU -1 Sc AHU -3) (� dLE r 1 PREFERRED TRAP LOCATION AT UNIT 2. TRAP DEPTH DIMENSION "A" SHALL BE THE MAXIMUM POSSIBLE NEGATIVE PRESSURE IN THE UNIT AT THE DRAIN OUTLET ON INCHES W.G.) PLUS ONE INCH. IF THE PRESSURE IS POSITIVE, "A" SHALL BE ONE INCH. 3. TRAP DEPTH DIMENSION "B' SHALL BE HALF OF "A' PLUS ONE INCH IF OUTLET IS UNDER NEGATIVE PRESSURE. IF THE PRESSURE IS POSITIVE, IT SHALL BE THE MAXIMUM POSSIBLE PRESSURE (IN INCHES W.G.) PLUS TWO INCHES. CEILING MOUNTED CHILLED WATER COMPUTER ROOM COOLING UNIT PIPING DIAGRAM � SCALE: xoT4E ACCEPTABILITY �6 AloPROWD Bv O FOR VENTING DRAIN PAN CONNECTION 1 1/2" TO FD - 'AUXILIARY AIR CONDEHONING EQUIPMENT CONDENSATE PUMP FURNISHED WITH SOME UNITS • OOGIE 3 " dam 1 MEM 5" k' BAL. VALVE (TYP) SAME SIZE AS HEADER CONN. (TYP) LOCATE RISERS SO AS TO NOT BLOCK COIL REMOVAL 07.2506 07.2506 TRAP W/ PRIMING PORT (4 "DEEP SEAL) 2 -WAY PRESSURE INDEPENDANT CONTROL VALVE (TYPICAL) MEN MASTER MEMORY STOP r � CHILLED WATER RETURN 1\_ CHILLED WATER SUPPLY 1/2" DRAIN AT LOWEST HEADER (FLOW OR RETURN) ISSUED FOR CONSTRUCTION I PIPING DETAILS 9-98 RENOVATION BUILDING 9-98 LEGEND WYE STRAINER (W/ DRAIN VALVE) l � THERMOMETER i� UNION AUTOMATIC MR VENT (WITH DRAIN) GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES 3/4 "AUXILIARY CONDENSTAE DRAIN 9' (MOUNTED ABOVE CEIUNC NOT MORE THAN 6' FROM AC UNIT) WA N ASTINEEIS 1601 Fah knave Sage 900 Scorn. 11351.11glon 98101 206 623 0717 Fax 206 624 3775 • DEV. CENTER,WA TEST PLUG BALL VALVE GATE VALVE 2 -WAY CONTROL VALVE BUTTERFLY VALVE GATE VALVE WITH HOSE CONNECTION AUTOMATIC FLOW CONTROL VALVE WATER SENSOR 9"x9 x2 "D 26 GAGE K K GALVANIZED SHEETMETAL WATER TIGHT PAN AUXILIARY DRAIN PAN DETAIL n ammo venom 4140799 -00 M508 140799 -00 ONG ND. 9- 98 -M508 ci7: 1:; %i.:; COMP NO. 0815.06 4" STEAM SEPARATOR 0 -200 PSI SHUT -OFF VALVE (TYPICAL) 4" 9-98 REHOVI1u1 LOW PRESSURE STEAM PRV DETAIL (PENTHOUSE) n PIW5�M509 SCALE: NONE T- -� THERMODYNAMIC TRAP 250 LBS /HR 4" VENT TO ATMOSPHERE FROM PRV o -sow OVERFLOW 1 -1/2" v THERMOSTATIC AIR VENT STEAM SEPARATOR SCALE: NONE PRESSURE POWERED PUMP STEAM TRAP 4140799 -00 RECENER COMM r MIN. 10 PIPE PRV -1 Si DIAMETERS OF 4 CONDENSATE 1I FLOAT & THERMOSTATIC APPROVED D4 14 v z p W MOM t 3/4" 4" CONDENSATE RETURN 1", 60 PSI MOTIVE STEAM DRAIN 1 2 "t . PRESSURE POWERED PUMP CONDENSATE 00.1506 1_ 2" 2 -1 2" TO CONDENSATE RETURN NOTE: PIPE SIZES ARE FOR PACKAGE CPP-1B. SEE DETAIL f2 ON 1M452 FOR CPP --1A PIPE SIZES STEAM CONDENSATE PUMP PACKAGE DETAIL (1 SCALE: NONE ,uau�iaov MIN. 15 FT OF STRAIGHT PIPE STEAM METER (1 L 1 1 PRESSURE GAGE, W/ PIGTAIL AND SHUT -OFF VALVE, TYPICAL 0 -60 PSI RELIEF VALVE, 6 VTR, 12,000 LB /HR DISCHARGE PIPE TO DRIP PAN ELBOW 15 PS1G REDUCED PRESSURE STEAM 12 PRESSURE REDUCING VALVE 3" INLET, 6" OUTLET COMP AIR 3/4" STEAM METER INSTALLATION D PIY15015509 MIN. 4 FT OF ( , 1 STRAJcHT PEE 6" STEAM SEPARATOR 0 -200 PSI SHUT -OFF VALVE (TYPICAL) 3/4" SCALE: NONE CONTROL VALVE 2" FOR HC -1 & HC -3 2-1/2" FOR HC -2 & HC -4 SCALE: NONE SCALE: NONE 3/4" THERMODYNAMIC TRAP 60 LBS /HR SEE SIZES ON PENTHOUSE DWGS STEAM SEPARATO PRV -3 CONDENSATE 15 PSI STEAM SAFETY RELIEF VALVE CONDENSATE . INLET J . v DIRT LEG p D4 1 r - TO PIPING MIN. 10 PIPE DIAMETERS OF STRAIGHT PIPE PUMP TRAP 1 " MEDIUM PRESSURE STEAM PRV DETA1L(MECH. RM. 11E7) (2 - 1 fzlusoe CHECK VALVE 3/4" m l e- VENT 1 /2 "STM - 1i D4 � f-- t�F-ca 1" CLEAR AIR GAP 15 PSI y MOTIVE STEAM SAFETY VALVE DISCHARGE ELBOW WASTE TO OPEN DRAIN PRESSURE GAGE, W/ PIGTAIL AND SHUT -OFF VALVE, 0 -100 PSI RELIEF VALVE, 1 "VTR, 1,000 L6 /HR DISCHARGE PIPE TO DRIP PAN ELBOW 60 PSIG REDUCED PRESSURE STEAM PRESSURE REDUCING VALVE 3/4" INLET, 1 OUTLET CONDENSATE v 1= RETURN UNE IH STEAM COIL WITH PUMP TRAP PACKAGE DETAIL ( PIY15oFtYU�M5a9 OAT & THERMOSTATIC STEAM TRAP STEAM SAFETY RELIEF VALVE (PSV) DISCHARGE DETAIL n IY130�IC09 A E IAB1 Y SPECIROMON nos ti aim S COMM oro SEIM awn Mb 07.2506 07.25.06 SWINK 0 CO ifEaurar,AL MASTER THREE TURN SWING JOINT DETAIL SCALE: NONE E SCALE: NONE I ISSUED FOR CONSTRUCTION • THERMOSTATIC AIR VENT AT rts � — END OF MAIN AND AT PRV STATIONS PROVIDE RILL sIzE r " \ / DRIP LEG AT END OF MAIN OR AT RISER ELEVATION MEDIUM PRESSURE DRIP LEG AND TRAP DETAIL n SCALE: NONE �- DRIP LEG TO BE LINE SIZE GATE VALVE lYP NC EQUIPMENT CONNECTION 3/4" FREE BLOW DRIP LEG MAIN STEAM LINE `( 1 UNION STRAINER TYP DRIP LEG �---� 1" SCH. 80 TO DRAIN 1" SCH. 80 UNION STRAINER GV t � 1/2 BLOWDOWN LOW PRESSURE DRIP LEG AND TRAP DETAIL (9 AFOFFIVIAN 6 1 1 EELS 1601 FS M pe Sale 900 Sedge, Washington 98101-1625 206 623 0717 fax 206 624 3775 STEAM SYSTEM DETAILS 9-98 RENOVATION BUILDING 9-98 TO EQUIPMENT CHECK SIZE AS INDICATED VALVE . ON PLANS PLAN -TEST VALVE NOTE: PIPING TO TURN IN TWO PLANES. OFFSETS TO BE 6X DIA., 6 MINIMUM DELI CENTER,WA TEST VALVE, SEE PLAN VIEW 1 ABM REVISION SY180! , 140799 -00 SHER 109N. 140799 -00 a1c NO. M509 CONNECT TO TOP OF CONDENSATE MAIN FLOAT & THERMOSTATIC STEAM TRAP TO COND. RETURN MAIN 9- 98 -M509 COMP ND. 1 08.15.06 ■ AIR PLAN VIEW i ii A/D A/D /D(3) /D(4) 24W X 66H 24W X 66H 24W X 66H . 30W X 66H DEMOUNT = 96 UNIT LENGTH = 295 2" 20ga Solid GaIv. = 295 DEMOUNT = 84 ' 1 - 36 —ad 24 36 --I 24 F---- 60 RIGHT ELEVATION VFD VFD *A /D TOSL(5) 30W X 66H MAIN DISCON. DEMOUNT = 115 ACCt55 DOOR 1" FLANGE nit A /D(1) A /0(2) A /D(3) A /D(4) 24W X 6• 24W X 6• 24W X 6• OW X 66H PLAN VIEW UNIT LENGTH = 236 2" 20ga Solid GaIv. = 236 9- NOM1K 4 4140799 --00 corms B• '. ��, AIR HANDLING UNIT DETAILS WNW& MASTER KV. CENTER,WA °Pc N0. 9- 98- 14510 DATE 08.15.06 I36 36 —4 24 1 '. 48 AHU -2 HOT DECK DETAIL M MAIN DISCON. A/0 TOSL(5) 30W X 66H FLANGE • • • • s