Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M06-201 - WESTFIELD SOUTHCENTER MALL - GUESS
GUESS 321 SOUTHCENTER MALL EXPIRED 08 -11 -07 M06 -201 Parcel No.: Address: Suite No: City 6i' Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 - 3670 Fax: 206 - 431 - 3665 Web site: ci.tukwila.wa.us 2623049004 321 SOUTHCENTER MALL TUKW Tenant: Name: GUESS Address: 321 SOUTHCENTER MALL, TUKWILA WA Owner: Name: WESTFIELD CORPORATION LLC Address: 11601 WILSHIRE BL, LOS ANGELES CA Contact Person: Name: GREG WINCHESTER Address: 1950 CRAIG RD, STE 300, ST LOUIS MO Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N, KENT, WA Contractor License No: HERMACLOO5BJ Value of Mechanical: $15,000.00 Type of Fire Protection: SPRINKLER Furnace: <100K BTU >100K BTU Floor Fumace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig/Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial /Industrial doc: IMC- Permit MECHANICAL PERMIT DESCRIPTION OF WORK: RELOCATION OF EXISTING UNIT, DUCTWORK, ETC. ONLY A FEW SECTIONS OF DUCT SHOULD BE NEW, EVERYTHING WILL BE RELOCATED. EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 1 0 0 0 0 0 0 0 "continued on next page** M06 -201 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 314 415 -2400 Phone: 206- 575 -9700 Expiration Date:08 /25/2008 Steven M. Mullet, Mayor Steve Lancaster, Director M06 -201 10/19/2006 04/17/2007 Fees Collected: $327.20 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU 30 -50 HP/1,750,000 BTU 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 5 Thermostat 1 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 10 -19 -2006 Permit Center Authorized Signature: I hereby certify that I have read and ordinances governing this work will b Signature: Print Name: doc: IMC- Permit City t Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: cttukwila.wa.us v t� /r 44°it Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -201 Issue Date: 10/19/2006 Permit Expires On: 04/17/2007 Date: to( Vt to. is permit and know the same to be true and correct. All provisions of law and with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th performance of work. I am authorized to sign and obtain this mechanical permit. Date: /d7p- d This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M06 -201 Printed: 10 -19 -2006 City oie Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Parcel No.: 2623049004 Address: 321 SOUTHCENTER MALL TUKW Suite No: Tenant: GUESS 1: "'BUILDING DEPARTMENT CONDITIONS*** PERMIT CONDITIONS Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -201 Status: ISSUED Applied Date: 09/21/2006 Issue Date: 10/19/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ***FIRE DEPARTMENT CONDITIONS*** 11: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct Installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 13: Fire alarm systems shall be maintained in an operative condition at all times. Fire alarm systems and their component parts shall be inspected and tested per manufacturer's specifications and N.F.P.A. 72 at a minimum frequency of every twelve months. A copy of inspection, test and maintenance records shall be forwarded to the Tukwila Fire Prevention Bureau. (NFPA 72 (10.2.1.1)) (City Ordinance #2051) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) doc: Conditions M06 -201 Printed: 10 -19 -2006 City ori Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: cL.tukwila.wa.us 15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) Steven M Mullet, Mayor Steve Lancaster, Director 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the Washington State Department of Labor and Industries is required for this project. 19: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Conditions **continued on next page** M06 -201 Printed: 10 -19 -2006 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doe: Conditions City or Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Peve 44. tic Steven Al Mullet, Mayor Steve Lancaster, Director Date: /;/pseL M06 -201 Printed: 10-19 -2006 CITY OF TUKWI Community DevelopnlTht Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hitp: / /www.cttukwila.wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** AA'' King Co Assessor's Tax No.: 'Lll4 �V'L 1 Site Address: V Sovcs-N c.ENWEE. Mph ti , Tenant Name: C, 1r,.E55 Property Owners Name: WEST F/e ) Mailing Address: 1/6 O / t..,) t fA M it( /3L ✓E. Flt. 9 GDS 4f), -.EGGS , CM 'rocas City state CONTACT PERSON — who do we contact when your permit is ready Name: at (Ii (.3f&UtESrE& Mailing Address: !?SSCRft/P, LI) Aire 30o 57; Cows ° $10 G 3, y (✓ City Stan Zip E -Mail Address: CZ/9lccwEsr&e-& 4Pc1. r".0 en. Fax Number. Atd - tflf -. GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) hr Plumbing and Gm Piping (pg 5)) Company Name: Mailing Address: Ts b Contact Person: E-Mail Address: Contractor Registration Number: ARCHITECT OF RECORD - Alt plans must be wet stamped by Architect of Record Company Name: Ae .VI ISIeA.1 - Z,3c. — rtterr .eirt' Y t� orr, 7 615 Mailing Address: 1960 Cs€IMr, £0 . Fi sto re Soo SE Lou is el&-t) (o31tile Ciy State Zip Contact Person: ea e-Era f i t N c- -tE-enT Et Day Telephone: - 3 H 4-1)5 ,a.rfoo Fax Number. 3 yi5 a3o E -Mail Address: ( t's, HFs1 Aec1. r.. ..... Company Name: Mailing Address: Contact Person: E -Mail Address: Q:'Appfieadem\Femu-AppIieadenn On IineV -2006 -Permit Appliendm doe Raised: 9.2006 bb Building Pern Mechanical Permit No. Plumbing/Gas, Permit No, Public Works Permit No. Project No. : a(o Q -` i(Forofticevse on Suite Number Floor: New Tenant: ❑ Yes El -No Day Telephone: 31q- co 5 • Ago 0 State State Tap Zip City Day Telephone: Fax Number: Expiration Date: I ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Zip Ciy Day Telephone: Fax Number: Page I of 6 UII:UING PERMIT INFO ' jION = 206-431 -36 Valuation of Project (contractor's bid price): S 517. 0v0 Existing Building Valuation: S Scope of Work (please provide detailed information): 1%.i s# (Zsvt a t - Pt - C r ` tt -;4 . I H o r � 2.�.isf :+� L-.) 4 - �nna�r ' ;,, £- AJe.6+� 1215 { r,AiiI.•% P SA $ .fie „J 1 ow��f tt\ . 4 — dF ¢x1SI:ft. P.t Will there be new rack storage? I Yes 9.. No If yes, a separate permit and plan submittal will be required. ProvtdeAlL Bolding Area§ i t Square F ootage Below 3l? Pr Addition to Extsbng : truettue ,* Construction per <- - SPr,�al<re61 Oceupabcy per " '7 CO: elteco- ,.1414. PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 113 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes J' No if "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: E Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 181 No If `yes', attach list of materials and storage locations on a separate 8 - 1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. QUpplicmm.sWouus- Applications On Line13-2006 - Permit APPac.canAne Revised: 93006 Page 2 of 6 t Fixture Type:. Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas I PLUMBING AND GAS PIPINERMIT INFORMATION 206 -431 -' (�y Lo• PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number. Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q: Appricanme'Fotm.Applications On Line U3006 -Pent Appliuton cinc Rated: 9-2006 bb State Tip Page 5 of 6 • ski PERMIT APPLICATION: NOTES; Ap plicable to.all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Gr l 1 .. ")1n..J4.r. Print Name: Oaf?FGa lJ I Date Application Accepted: M 1ija e q: Applications \Forms-Appliations On Line \3 -2006 - Permit Appliatie0.doc Revised. 9-2006 6n Day Telephone: City Date: l -20-0€7 304 Kip .2goo Mailing Address: I CK 041t� P1� 5c-Ire 3oc> E.T, WtotS vl/l(� (.3tMfy State Zip Date Application Expires: m 1 103._ Staff Initials: - I Page 6 of 6 RECEIPT NO: R06 -01673 Initials: JEM Payment Date: 10/19/2006 User ID: 1165 Total Payment: 1,131.00 Payee: BNBUILDERS, INC. SET ID: 1019 SET NAME: GUESS SET TRANSACTIONS: Set Member Amount D06 -349 M06 -201 TOTAL: TRANSACTION LIST: Type Method Description Payment Check 22440 1,131.00 TOTAL: 1,131.00 ACCOUNT ITEM LIST: Description 863.24 267.76 863.24 BUILDING - NONRES MECHANICAL - NONRES STATE BUILDING SURCHARGE SET RECEIPT Account Code Current Pmts 000/322.100 858.74 000/322.100 267.76 000/386.904 4.50 TOTAL: 1,131.00 Amount .0/19 9716 TOTAL 1131.00 Copy Reprinted on 09 -21 -2006 at 12:00:49 09/21/2006 RECEIPT NO: R06 -01480 Initials: JEM User ID: 1165 Payee: ARCVISION INC. SET ID: 0921 SET TRANSACTIONS: Set Member D06 -349 M06 -201 TOTAL: 4v' � City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Amount 558.18 59.44 617.62 SET RECEIPT Payment Date: 09/21/2006 Total Payment: 617.62 SET NAME: Temporary Set TRANSACTION LIST: Type Method Description Amount Payment Check 13438 617.62 TOTAL: 617.62 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES Account Code Current Pmts 000/345.830 TOTAL: 617.62 617.62 9973 09/21 9716 TOTAL 617.62 Steven M Mullet, Mawr Steve Lancaster, Director COMMENTS: Type of Inspection: EA / IWAG ILIME* LT 0 Eta (.T= Dtt> NoT +1J(.o. i FT /C 7 = Nct0 A.u✓LC 1AC,ti I*Lp0 (a (I N INt D K - 4-\■f Ac, o tt Phone No.: - FAX SItN (lb CFIIT. Occupancy Type: 0 SP2tNK - OELn P Q(,I � Si 71k(2DJ OAT t)T Project: G „ E55 Type of Inspection: EA / IWAG ILIME* LT Address: 3z I SCI- 1-06 C /41- n 2- MI-- Suite #: Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: - Permits: Occupancy Type: 2 INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS --I 1 f Corrections required prior to approval. Date: 2/12 /D 7 Hrs.: Inspector: a w 5 /2. , I P n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 07-02 -2007 GREG WINCHESTER 1950 CRAIG RD, STE 300 ST LOUIS MO 63143 Dear Permit Holder: City of Tukwila RE: Permit No. M06 -201 321 SOUTHCENTER MALL TUKW Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted permit has not received a foal inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be In writini and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 08/11/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Ter Marshall, Permit Technician xc: Permit File No. M06 -201 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M06 -201 DATE: 09 -21 -06 PROJECT NAME: GUESS SITE ADDRESS: 321 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Apt* ui Ling Division Olt Public Works Complete Comments: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 7 -28 -02 +.) PERMIT COORD COPY ‘.,. Approved with Conditions al mw/ ia .0 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ ❑ Permit Coordinator ❑ Planning Division DUE DATE: 09-26-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required DATE: DUE DATE: 10-24 -06 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License HERMACL005BJ Licensee Name HERMANSON COMPANY LLP Licensee Type CONSTRUCTION CONTRACTOR UBI 602004844 Ind. Ins. Account Id PARTNER/MEMBER Business Type LIMITED LIABILITY COMPANY Address 1 1221 2ND AVE N Address 2 City KENT County KING State WA Zip 980322945 Phone 2065759700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/11/2000 Expiration Date 8/25/2008 Suspend Date Separation Date Parent Company Previous License HERMAC'217NT Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HERMANSON, RICHARD L PARTNER/MEMBER 01/01/1980 ALMON, KEVIN PARTNER/MEMBER 01/01/1980 MACDONALD, JAMES PARTNER/MEMBER 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Page 1 of 2 https: // fort ress.wa.gov /lni/bbip /printer.aspx ?License= HERMACL005BJ 10/19/2006 GUE WESTFIELD SOUTHCENTER SEATTLE, WA SPACE #116 STORE #5089 By Date : Jay. aty of BUILDING ON Plan review approval Is subject to ems and o Approval of c nstrudion documents does not authorise the %elation of any accepted coda or ordnance. Reedt of approved Field Copy conditions b adQ o gedped: No changes shall be made to the scope c? work without prior approval of Tu::Yr113 Building Division. require a new plan submittal and r r.y include cdditional plan review fees. 518 TUKWILA PKWY STRAND©R BLVD_ WESTFIE D'S SOUTHCENTER EXI AUC-i 1 1 [flu mraimuraireallzimminvInliraml •IUIRIIIIIUIIE 'A 3Tl �� C.TF.�u'�Cb.r'SIM���1��R'.'J'' L'' uIr" rT' s�'. F��n��CC� ^.TZ�u'�7��Ei��'��AIIIIINM17S� ■■■■■■■ ��■■■ ����' .. r3�? c�7�■■■ �Lr]" ur[ �u�L��.' r. ��C��� ^_3��9 ■ ■ ■ ■■C!l::G�Sti'�' �7�L�iC ■ ■�i1�� sinuniumumarizzi'm=mianinumrsimilmmunumnracimmounniimmunniummummormum minsmammuummmornmmnrimmumunnmammiummanniumammErmrnmasimmEssasommimmmmummirmeni SHEET DIME DETAIL IS SHOWN SECTION CUT CROSS SECTION ELEVATION ROOM NUMBER KEY NOTE PARTRION TYPE DOOR NUMBER MUSH ITEMS FIGURE TYPE ELEVATION BENCHMARK REVISION NUMMI GRAPHC SYMBOLS MIME 100 4 llil I1- .11. i i F■A ROUGH WOOD MASHED WOOD ® MOO BOARD RIGID NSI ATION BATT INSULATION GYPSUM BOARD i i EARTH STEEL • GRAMII`AR ALL POURED CONCRETE CONCREIE BLOCK i Rif ACE CK METAL CERAMIC ILE ISPHAULT PPNING CODE REVIEW CODES: BUILDING 2003 INTERNATIONAL BUILDING CODE PLUMBING: 2003 UNIFORM PLUMBING CODE MECHANICAL: 2003 INTERNATIONAL MECHANICAL CODE FIRE: 2003 INTERNATIONAL FIRE CODE ELECTRICAL: 2005 NATIONAL ELECTRIC CODE CONSTRUCTION TYPE: TYPE ii — SPRINKLERED USE GROUP CLASSIFICATION: MERCANTILE OCCUPANCY LOADS: SALES FLOOR 2,461 SQ. FT. DMDED BY 30 = 82 FITTING ROOM 326 SQ. FT. DIVIDED BY 30 = 11 STOCK ROOM 934 SO. FT. DMDED BY 300 = 3 TOTAL OCCUPANTS = 96 TOTAL SQ. FT. = 3,721 FIRE SUPPRESSION SYSTEM: TE'SW NO CI SITE LOCATION PLAN • GUESS SPACE 1116 NORDSTROM SPACE LOCATION PLAN MACY'S LEVEL. 1 OF 1 • F CC SEPARATE PERM REQUIRED FOR: 7=`" o Robing o Gus rgo tY of 1fdcwNa DING DIVISION MERVYN'S I L_ JC PENNEY AO .0 TITLE SHEET DRAWING INDEX AO .1 RESPONSIBILITY LEGEND AO.2 ARCHITECTURAL SPECIFICATIONS AO.3 DEMOLITION FLOOR PLAN AO.4 DEMOLITION CEILING PLAN A1.0 FLOOR PLAN Al .1 REFLECTED CEILING PLAN Al .2 FIXTURE PLAN A4.0 SALES AREA ELEVATIONS A4.1 STOCKROOM ELEVATIONS A5.0 WALL PARTITION & FLR. TRANS. DTLS. A5.1 TYPICAL FITTING ROOM DETAILS M1.0 MECHANICAL PLAN El .0 POWER PLAN E1.1 UGHTING PLAN E2.0 ELECTRICAL SCHEDULES E3.0 ELECT.L SPECS & ENERGY FORMS • REV DATE LU cn 00 0 cc 0 co w 0 amp cp cc a w U O O J W W ari--2_0( - - - urowis4 V I) • • • • /Ail AB F84 I I t.11. I I ( ~ �r I — Iw ardef4 , .t • 1 L.__ _J 0 Io 1 :I; I ' I: 0 ®0 0000 0 0 0 0 I ni IP ?: If R iM N i;i :g We' / M P le! g kr! 11 10 fi Jisfik 1 R4 p J Pi4 a 08 4 igg 1 go 2 2 ,1 a I 113 h hil 1108 Ip lig p § 8b1:; 0 I b P ki gg !g II I @NI! 1E2 16 4 I! gm 4112 1 i g e sal:1*oz 1 'IP, 11 101Abo II 1 6440111bbilTig 11 pi! sifiliiligiqhh .m§ ; 18 0'4 1 , pr! I 11 1 1 q $ 1.1 11111 M A 0 n ID ■ 0 8 ■ 0 00 ■ O CO N z w at : o 0 8 c/ U' ■ 0 C N N C In W 0 44 C N 8 m me Ti o m . N2m co o c e s in gm �O m C 0 Ii boor. r... „w 0 : N { 1r, N,. oo dler 1 \a __r•. _V:r �=__....__ r_...•. r. r_....__ rrrr. rr. rrw. rrr_._ wr. w.. rr.w rw_ w. .w..r.r..r.._r�-- ..— ..rrr —._.w� 0 1 !I N I A .-.. Io • l� r.� 1 / / I \ / ".' C7 ../ ) t,4 1. 1 • • •• IK� 0 CJ .0 1J b rnm !III Ip z� 4 104 M g-ARMI O Ogfilh 4 Z I 400 mtnv P 29 5rn tie w oPm v 0 • i i L.....1 I \ 1 ►�. 0 \./ A Iti <. / i • r•, w 0 ..... ,r .. S: .. V V ♦ I• • • • 1m MECHANICAL PLAN 1-131N10 IIVIIEd 3onvo s 91 'ON vvm > N •► Q1Y. 1 F] 10 300 -RI ;TITUS MODEL I 1 24'x24" 24 "x24' 24 "x24' N/A MODULE SIZE 1 [ERN UME DAMPER GH -IN OPENING -'x24" 1 t'x18" i" "x18' 1. .1 .. ACE NECK I FLEX 1ZE SIZE SIZE TYPE 122 ~ x22' 10" RD. 12" RD. 12'x6" I N/A 10" RD. 12" RD. N/A 1 I R.G. RIFF. DIFF. DIFF. A 1,3,4 1,3,4 1 1,2,3 NOTES I • • • • /Ail AB F84 I I t.11. I I ( ~ �r I — Iw ardef4 , .t • 1 L.__ _J 0 Io 1 :I; I ' I: 0 ®0 0000 0 0 0 0 I ni IP ?: If R iM N i;i :g We' / M P le! g kr! 11 10 fi Jisfik 1 R4 p J Pi4 a 08 4 igg 1 go 2 2 ,1 a I 113 h hil 1108 Ip lig p § 8b1:; 0 I b P ki gg !g II I @NI! 1E2 16 4 I! gm 4112 1 i g e sal:1*oz 1 'IP, 11 101Abo II 1 6440111bbilTig 11 pi! sifiliiligiqhh .m§ ; 18 0'4 1 , pr! I 11 1 1 q $ 1.1 11111 M A 0 n ID ■ 0 8 ■ 0 00 ■ O CO N z w at : o 0 8 c/ U' ■ 0 C N N C In W 0 44 C N 8 m me Ti o m . N2m co o c e s in gm �O m C 0 Ii boor. r... „w 0 : N { 1r, N,. oo dler 1 \a __r•. _V:r �=__....__ r_...•. r. r_....__ rrrr. rr. rrw. rrr_._ wr. w.. rr.w rw_ w. .w..r.r..r.._r�-- ..— ..rrr —._.w� 0 1 !I N I A .-.. Io • l� r.� 1 / / I \ / ".' C7 ../ ) t,4 1. 1 • • •• IK� 0 CJ .0 1J b rnm !III Ip z� 4 104 M g-ARMI O Ogfilh 4 Z I 400 mtnv P 29 5rn tie w oPm v 0 • i i L.....1 I \ 1 ►�. 0 \./ A Iti <. / i • r•, w 0 ..... ,r .. S: .. V V ♦ I• • • • 1m MECHANICAL PLAN 1-131N10 IIVIIEd 3onvo s 91 'ON • 0 0 0 0 0 0 c> 0 15 19 POWER NOTES RELOCATED CASHWRAP. RE —USE EXISTING POWER AND DATA. 20A RATED 0 +42" FOR MICROWAVE, COORDINATE EXACT LOCATION. 20A RATED U +15" FOR REFRIGERATOR, COORDINATE EXACT LOCATION. EXISTING ELECTRICAL IN RESTROOM TO REMAIN. NEW RECEPTACLE MOUNT AT 18" A.F.F. LOW VOLTAGE CHIME MOUNTED IN STOCKROOM CEIUNG, ACTIVATED BY A PUSH BUTTON SWITCH MOUNTED IN CASHWRAP (MOTHER STATION), SEE DETAIL ON SHEET E2.0 EDWARDS "725 LOW VOLTAGE DIXIE BUZZER MOUNTED I STO KROOM CEIUNG AND ANOTHER BUZZER LOCATED IN CAHSWRAP MOTHER STATION) TO BE ACTIVATED BY A PUSH BUTTON SWITCH AT BACK . SEE DETAILS ON SHEET E2.0. PROVIDE PUSH — BUTTON FOR BUZZER AT BACK DOOR AND PROVIDE PUSH — BUTTON FOR CHIME AT CASHWRAP SEE DETAILS ON SHEET E2.0 E.C. SHALL SUPPLY AND INSTALL THE FOLLOWING SERVICE BELL SYSTEM: o EDWARDS 52 PUSHBUTTON b EDWARDS 188-50 TRANSFORMER c EDWARDS 1340A—G5 BUZZER X8 d) EDWARDS I338 —G5 CHIME EXISTING SENSORMATIC SYSTEM TO REMAIN. Co PROVIDE 20AMP /110VOLT J —BOX AND DEDICATED DUPLEX RECEPTACLE (WITH ISOLATED GROUND) FOR ANTENNA DIRECTLY ABOVE THE DOOR. J —BOX NEEDS 1" CONDUIT WITH A PULL STRING TO RUN TO THE COMM. STRUCTURE. COORDINATE EXACT LOCATION AND SEE DETAIL ON SHEET E3.0. 11 FLUSH "J" BOX AT +42" WITH 3/4 "C. WITH PULL STRING TO CEIUNG SPACE FOR ROBBERY ALARM PAD. COORDINATE EXACT LOCATION AND OTHER RELATED ELECTRICAL REQUIREMENTS. RELOCATED COMM. STRUCTURE FIELD COORDINATE LOCATION WITH EXISTING EQUIPMENT IN ELECTRICAL ROOM. EXISTING DISCONNECT SWITCH FOR RTU TO REMAIN. EMBEDDED DOOR CONTACTS AND DOOR ALARM CONTACT MOUNTED IN HEAD OF DOOR FRAME WRH MAGNET MOUNTED IN TOP OF DOOR AT BACK OF HOUSE. PROVIDE JUNCTION BOX ABOVE CEIUNG WITH 1/2" CONDUIT STUBBED INTO HEAD OF DOOR FRAME. EXISTING DISC. SWITCH FOR DUCT HEATER TO REMAIN. EXISTING TIMECLOCK TO REMAIN. EXISTING PANEL 'A'. TRENCH FLOOR FOR INSTALLATION OF IN —FLOOR CONDUITS TO CASHWRAPS AND SENSORMATIC. PATCH FLOOR TO MATCH SURROUNDING FLOOR AREA. PRIOR TO TRENCHING, OBTAIN LANDLORD APPROVAL CONFIRM WITH LANDLORD FLOOR TRENCHING LOCATIONS DO NOT CROSS EXISTING UNDERGROUND UTILITIES. EXISTING PANEL 'B'. ® RELOCATED CU -1 RE —USE EXISTING DISC. SWITCH. PROVIDE NEW CONDUIT AND CONDUCTORS AS REQUIRED. FIELD VERIFY. O E.C. SHALL FIELD VERIFY EXACT REQUIREMENTS FOR SMOKE /FIRE ALARM SYSTEM. REUSE ANY EXISTING DETECTION SYSTEM. REPLACE ANY DEFECTIVE DEVICES. IF THERE IS NOT AN EXISTING SYSTEM, E.C. SHALL SUPPLY AND INSTALL ALL NECESSARY EQUIPMENT (SMOKE DETECTORS. AUDIO /VISUAL. ALARMS, FIRE ALARM PANEL, CONDUIT, WIRE, ET FOR A • SYSTEM AS MAY BE REQUIRED BY LANDLORD AND /OR LOCAL FIRE MARSHALL. INSTALL SMOKE DETECTORS IN SUPPLY OR RETURN DUCTWORK AS REQUIRED BY LOCAL AUTHORITY. FIELD VERIFY AND COORDINATE. EXISTING SHOW WINDOW RECEPTACLE LOCATED IN CEILING ABOVE WINDOW. PROVIDE POWER FOR FRONT CASHWRAP RECEPTACLES AND LIGHTS ROUTED FROM J —BOX CASHWRAP STUB UP. J —BOXES TO BE SURFACE MOUNTED ON STOCK ROOM SIDE. PROVIDE FIRE STOPPING AROUND CONDUIT PENETRATIONS TO MAINTAIN WALL FIRE RATING. RECEPTACLE AND SWITCHED LIGHT PROVIDED BY E.C. TO BE INSTALLED PER N.E.C. CIRCUITING INDICATED FOR EXISTING DEVICES IS FOR LOAD REQUIREMENTS. E.C. SHALL MAINTAIN EXISTING aRCURING WHERE POSSIBLE. FIELD VERIFY. DUSTING PHONEBOARD TO REMAIN. EXISTING FIRE ALARM PANEL TO REMAIN. EXISTING ALARM PANEL TO REMAIN. RELOCATED AHU -1 RE —USE EXISTING DISC. SWITCH. PROVIDE NEW CONDUIT AND CONDUCTORS AS REQUIRED. FIELD VERIFY. RELOCATED DUCT HEATER RE —USE EXISTING DISC. SWITCH. PROVIDE NEW CONDUIT AND CONDUCTORS AS REQUIRED. FIELD VERIFY. EXISTING RECEPTACLE TO REMAIN. ) PROVIDE (2) 1"C. TO COMM. STRUCTURE A -4 j'` DA I S V0 = 1 i vi B -1.11 SBUZZER /CHIM ANTENNA TO CAS • \ • 8 -22 TO EXIST. DISC. SW. 8-12 8 -12 B -14 I POWER PLAN I SCALE Ifir 1-0° B -22 0 8- 2527.29 4 • Powe PLAN SCALD VW - 1-0 TO J —BOXES IN STOCK ROOM • TO EXIST. DISC. SW. - T 7/-1/2,7 j7T� - Y.?2 TO EXIST. COMM. STRUCTURE 1 !w.3 r —7;7;772_ co S co s—e; IL S REVIEWED ��O CODE COM 7.. A0000%10 OCT 1 2 MI anycfTa W1oI1i G WASION ; A • AUG 1 1 [001 EXPIRED El E1.0 II III. 4,91,1 . I ___J 1 ‘1--- i 1 imi g. _ 1 �! ;Wrt Q 40 3 � Q I 1 I E - I • icos Q� ' 13 1 � j j t t I j ' J LP 1 1 1 • f E • i = { I E 1 I I • 0 0 0 0 0 0 c> 0 15 19 POWER NOTES RELOCATED CASHWRAP. RE —USE EXISTING POWER AND DATA. 20A RATED 0 +42" FOR MICROWAVE, COORDINATE EXACT LOCATION. 20A RATED U +15" FOR REFRIGERATOR, COORDINATE EXACT LOCATION. EXISTING ELECTRICAL IN RESTROOM TO REMAIN. NEW RECEPTACLE MOUNT AT 18" A.F.F. LOW VOLTAGE CHIME MOUNTED IN STOCKROOM CEIUNG, ACTIVATED BY A PUSH BUTTON SWITCH MOUNTED IN CASHWRAP (MOTHER STATION), SEE DETAIL ON SHEET E2.0 EDWARDS "725 LOW VOLTAGE DIXIE BUZZER MOUNTED I STO KROOM CEIUNG AND ANOTHER BUZZER LOCATED IN CAHSWRAP MOTHER STATION) TO BE ACTIVATED BY A PUSH BUTTON SWITCH AT BACK . SEE DETAILS ON SHEET E2.0. PROVIDE PUSH — BUTTON FOR BUZZER AT BACK DOOR AND PROVIDE PUSH — BUTTON FOR CHIME AT CASHWRAP SEE DETAILS ON SHEET E2.0 E.C. SHALL SUPPLY AND INSTALL THE FOLLOWING SERVICE BELL SYSTEM: o EDWARDS 52 PUSHBUTTON b EDWARDS 188-50 TRANSFORMER c EDWARDS 1340A—G5 BUZZER X8 d) EDWARDS I338 —G5 CHIME EXISTING SENSORMATIC SYSTEM TO REMAIN. Co PROVIDE 20AMP /110VOLT J —BOX AND DEDICATED DUPLEX RECEPTACLE (WITH ISOLATED GROUND) FOR ANTENNA DIRECTLY ABOVE THE DOOR. J —BOX NEEDS 1" CONDUIT WITH A PULL STRING TO RUN TO THE COMM. STRUCTURE. COORDINATE EXACT LOCATION AND SEE DETAIL ON SHEET E3.0. 11 FLUSH "J" BOX AT +42" WITH 3/4 "C. WITH PULL STRING TO CEIUNG SPACE FOR ROBBERY ALARM PAD. COORDINATE EXACT LOCATION AND OTHER RELATED ELECTRICAL REQUIREMENTS. RELOCATED COMM. STRUCTURE FIELD COORDINATE LOCATION WITH EXISTING EQUIPMENT IN ELECTRICAL ROOM. EXISTING DISCONNECT SWITCH FOR RTU TO REMAIN. EMBEDDED DOOR CONTACTS AND DOOR ALARM CONTACT MOUNTED IN HEAD OF DOOR FRAME WRH MAGNET MOUNTED IN TOP OF DOOR AT BACK OF HOUSE. PROVIDE JUNCTION BOX ABOVE CEIUNG WITH 1/2" CONDUIT STUBBED INTO HEAD OF DOOR FRAME. EXISTING DISC. SWITCH FOR DUCT HEATER TO REMAIN. EXISTING TIMECLOCK TO REMAIN. EXISTING PANEL 'A'. TRENCH FLOOR FOR INSTALLATION OF IN —FLOOR CONDUITS TO CASHWRAPS AND SENSORMATIC. PATCH FLOOR TO MATCH SURROUNDING FLOOR AREA. PRIOR TO TRENCHING, OBTAIN LANDLORD APPROVAL CONFIRM WITH LANDLORD FLOOR TRENCHING LOCATIONS DO NOT CROSS EXISTING UNDERGROUND UTILITIES. EXISTING PANEL 'B'. ® RELOCATED CU -1 RE —USE EXISTING DISC. SWITCH. PROVIDE NEW CONDUIT AND CONDUCTORS AS REQUIRED. FIELD VERIFY. O E.C. SHALL FIELD VERIFY EXACT REQUIREMENTS FOR SMOKE /FIRE ALARM SYSTEM. REUSE ANY EXISTING DETECTION SYSTEM. REPLACE ANY DEFECTIVE DEVICES. IF THERE IS NOT AN EXISTING SYSTEM, E.C. SHALL SUPPLY AND INSTALL ALL NECESSARY EQUIPMENT (SMOKE DETECTORS. AUDIO /VISUAL. ALARMS, FIRE ALARM PANEL, CONDUIT, WIRE, ET FOR A • SYSTEM AS MAY BE REQUIRED BY LANDLORD AND /OR LOCAL FIRE MARSHALL. INSTALL SMOKE DETECTORS IN SUPPLY OR RETURN DUCTWORK AS REQUIRED BY LOCAL AUTHORITY. FIELD VERIFY AND COORDINATE. EXISTING SHOW WINDOW RECEPTACLE LOCATED IN CEILING ABOVE WINDOW. PROVIDE POWER FOR FRONT CASHWRAP RECEPTACLES AND LIGHTS ROUTED FROM J —BOX CASHWRAP STUB UP. J —BOXES TO BE SURFACE MOUNTED ON STOCK ROOM SIDE. PROVIDE FIRE STOPPING AROUND CONDUIT PENETRATIONS TO MAINTAIN WALL FIRE RATING. RECEPTACLE AND SWITCHED LIGHT PROVIDED BY E.C. TO BE INSTALLED PER N.E.C. CIRCUITING INDICATED FOR EXISTING DEVICES IS FOR LOAD REQUIREMENTS. E.C. SHALL MAINTAIN EXISTING aRCURING WHERE POSSIBLE. FIELD VERIFY. DUSTING PHONEBOARD TO REMAIN. EXISTING FIRE ALARM PANEL TO REMAIN. EXISTING ALARM PANEL TO REMAIN. RELOCATED AHU -1 RE —USE EXISTING DISC. SWITCH. PROVIDE NEW CONDUIT AND CONDUCTORS AS REQUIRED. FIELD VERIFY. RELOCATED DUCT HEATER RE —USE EXISTING DISC. SWITCH. PROVIDE NEW CONDUIT AND CONDUCTORS AS REQUIRED. FIELD VERIFY. EXISTING RECEPTACLE TO REMAIN. ) PROVIDE (2) 1"C. TO COMM. STRUCTURE A -4 j'` DA I S V0 = 1 i vi B -1.11 SBUZZER /CHIM ANTENNA TO CAS • \ • 8 -22 TO EXIST. DISC. SW. 8-12 8 -12 B -14 I POWER PLAN I SCALE Ifir 1-0° B -22 0 8- 2527.29 4 • Powe PLAN SCALD VW - 1-0 TO J —BOXES IN STOCK ROOM • TO EXIST. DISC. SW. - T 7/-1/2,7 j7T� - Y.?2 TO EXIST. COMM. STRUCTURE 1 !w.3 r —7;7;772_ co S co s—e; IL S REVIEWED ��O CODE COM 7.. A0000%10 OCT 1 2 MI anycfTa W1oI1i G WASION ; A • AUG 1 1 [001 EXPIRED El E1.0 °E1 411 cEll gli f 1 1C1 e 11 P11 la y 1 A1 u° °E ticIPII cEj V I ap ld - °411 e 11 P11 la 411 u° °E ticIPII V MEEL. 1 -: a r a—U ■ ireNammul III MIME ■ Ue8w6 T INAW MIMI= a S 03:;._. t. , 00c 2JTS `C101:1 01A10 � I • • • • Ogil2 U ELL1 4 111 07 � 07S 1 1 1111 111 1 " " a III , aAle HIRIE0 5b --- Ittti ___ _ ___.___ _.__..___ ._*f. r.rrir wr•...rw._.rm.. rrrrr Ntl'Id DN1LHOfl 90/0 Z/6 wwwrww ..r_I :isms { s3 woofs - .._ S3 WNW , _ -- - I r W 1 , I ' .,.1, 1 2 w a a n a a a a a W w w W W W W W W V 'f Ui MUM 3N11 Hal.W4 N C7 Hui W W W W W W W W. ,gil I ,I► ■ I�1 I I ? 1 . 04, L•; w M O , Ult .' N 03:g LT, uJ t; v v .1 • i+ � ®t h ; 1 0 1 g E 1 811 II II h c.1 kei 4c; higNi gpsp o! *14 • • • I • • • • 4V UGHT FDMME ECF EDULE LAMP 9CieDULE QTY SYMBOL TYPE MANUFACTURER CATALOG NO. DESCRIPTION NOTES VOLTS REC SUR PEN WAL MANUFACTURER/ FlIXT LAMP/ FIXTURE TTS CATALOG NO. CKT. DESCRIPTION WATTS EXISTING EXISTING PENDANT FIXTURE 120 lit WATTS X CKT. 1 125 125 11 0 B JUNO - c enAsr 6� ROUND HIO 1111 120 X ■�■ --- SPARE 1 70 95 MHC7O/C /U /MP /4X - 0 D EXISTING EXISTING RECESSED MID FIXTURE 12 120 X ■ ■ ■ 1 125 LTG - FITTING ROOM 1045 - V E EXISTING EXISTING TRACK FIXTURE AND TRACK REC - REFRIGERATOR 120 M ■ ■ 1 75 75 - - 0 F EXISTING EXISTING RECESSED INCAND. FIXTURE 120 X ■ ■ ■ i 75 75 9 8 1125 L MEfALUX 81SS232 UNV -E881 (2) 4' NARROW STRIP MOUNTED IN TANDEM 1 120 Mal X - - 4 32 114 SYLVANIA F32T8/11.835 /ALTO 1 1===1 - ME►ALUX X232-- UNV -E881 48 FLUORESCENT CfM OPEN LAMP 1 120 X -- SPARE 14 2 32 62 -- 12 1327 H1 EXISTING EXISTING S�" ilBPUGHTFLUORESCENT OPEN LAMP - 120 X SPARE 16 15 2 32 62 SYLVANIA F3 13 REC - GENERAL 1 - -{ I UGHTOUER TCU4 LIGHT WITH SWITCH STRIP 1 120 X 17 EXIST LTG -TRACK 900 2 32 62 SYLVANIA F3218/R835 /ALTO 100 1■■P Da SUREUTE AP2SQ WALL PACK EN WITH LiGFR 1 120 19 X -- - 2 -- 10 -_ 4 6i EM2 EXISTING COSTING WALL E LIGHT 900 120 22 X EXIST LTG -TRACK 1800 2 -- 10 __ 1 EM3 L EEU- U- R -W -£M COMBO LED EXIT EMERGENCY ICY UGHT w/ LEAD/ BATTERY i 120 EXIST ST LTG -TRACK X 1 19 2 -- 10 -- 3 ® Xi PATHWAY LTEXICRC LED Nom/ SIGN. CAD 1 120 EXIST LTG -TRACK X 25 EXIST LTG - TRACT( -- -_ 3 INCLUDED -- ® X2 EXISTING DOS RIG W1iTH FACE EOT B L _500� 120 - X SPARE 28 __ __ 10 INCLUDED 1 . LAMPS AND FIXTURES E.S SUPPLIED BY GUESS AND "STALLED BY ELECTRICAL CONTRACTOR MESS OTHERWISE NOTED. 2. FIXTURES SWAM WITH CROSS -HATCH ME TO BE NIGHT UGHTS. FIXTURES USED FOR EXIT, EMERGENCY, OR NIGHT LIGHTING TO BE ON LOCKOUT CIRCUIT. 3. BATHROOM UGHT FIXTURE TO BE 120/ TO ALLOW CONNECTION TO DA sT FAN. PANELBOARD DESIGNATION A NEW EXIST X RELOCATED 120/208 VOLTS 4 WIRE, SOLID NEUTRAL MOUNTED: FLUSH SURFACE X 3 PHASE 4 00 AMPERE BUS ' AMPERE MAIN L008 FED FROM: TOP BOTTOM .AM PERE CKT. DESCRIPTION WATTS L am , gg A Vg lit WATTS DESCRIPTION CKT. i !' 0 740 1220 - SPARE 2 1 1 LTG -EXIT EM N. L. 706 1 12 12 EXIST- -ALARM PANEL 2 --- SPARE 4 3 LTG -STOCK 740 L NM a = 3 REC- MICROWAVE 900 M 12 12 - - -- SPARE 6 5 LTG - FITTING ROOM 1045 L 12 12 1125 104 REC - REFRIGERATOR 720 M 12 M 7 EXIST LTG-DOWN 1125 L - - -- SPARE 8 500 7 - - -- SPARE 10 9 EXIST LTG -DOWN 1125 L 12 - M `� ■�� Mal M - - -- SPARE 12 11 SPARE -- - = 10 O - - -- SPARE 14 13 EXIST LTG- PENDANT 1325 L 12 1327 12 �500_ 1200 REC - PHONEBOARD - - -- SPARE 16 15 EXIST LTG -TRACK 1500 1 12 13 REC - GENERAL R 12 12 L 1125 DUST LTG -TRACK 18 17 EXIST LTG -TRACK 900 L 12 - 12 12 WOO - 100 202 15 12 L 900 EXIST LTG -TRACK 20 19 SPARE -- - illm 2700 920 12 L 900 EXIST LTG -TRACK 22 21 EXIST LTG -TRACK 1800 1 r 18 j 12 L 900 EXIST LTG -TRACK 24 EXIST ST LTG -TRACK 900 1 19 SPARE -- - 202 --- SPARE 20 12 L 900 EXIST LTG -TRACK 26 25 EXIST LTG - TRACT( 1125 L 12 12 R 180 EXIST -RTU RECEPT 22 _500� - - -- SPARE 28 27 EXIST LTG - STOREFRONT 1500 L 12 12 I -- 29 EXIST LTG - STOREFRONT 500 L � r M - - -- SPARE 30 672 H - ` -- - - -- SPARE 32 31 EXIST LTG - STOREFRONT 900 L 12 00_ r75 - - -- 33 EXIST LTG - STOREFRONT 375 L 12 12 - -- 12 L 625 EXIST LTG - PENDANT 34 0 017 29 672 35 EXIST LTG - STOREFRONT 900 L - - -- SPARE 36 � 900 � � 31 SPACE - - _- SPACE 38 37 SPARE -- - ANN Mil - - -- SPACE 40 39 SPACE -- - - -- `� � _ Wili - - -- SPACE 42 41 SPACE -- -- -- - - - -- 36 i 1 37 25% LC.L 4922 SUB TOTALS 1 6981116440116270 I - CONNECTED LOAD 19691 DEMAND LOAD 24813 DEMAND AMPERES 08.4 __ PANELBOARD DESIGNATION 9 NEW EXIST X RELOCATED 120/208 VOLTS 4 WIRE, SOUD NEUTRAL MOUNTED: FLUSH SURFACE X .PHASE BUS 400 AMPERE MAIN L0 FED FROM: TOP BOTTOM .AM PERE CKT. DESCRIPTION WATTS LOAD TwE li A B I WC WATTS DESCRIPTION CKT. 1220 1 REC- MANAGER'S DESK 720 R 12 12 M 500 EXIST- -ALARM PANEL 2 4 PORTS, (2) DATA (2) VOICE TO COMM STRUCTURE 6' -0" 3 REC- MICROWAVE 900 M 12 12 M 500 REC -I.G. ANTENNA 4 4400 7 20 5 REC - REFRIGERATOR 720 M 12 - - -- SPARE 6 500 7 BUZZER 500 M 12 -- SPARE 8 midi 950 9 EXIST -WATER HEATER 750 M 12 12 12 M 200 EXIST -SENSORMATIC 10 O 1560 will 11 REC- MANAGER'S DESK 360 R 12 M 1200 REC - PHONEBOARD 12 1320 13 REC - GENERAL 720 R 12 12 M 600 EAST -UPS 14 100 15 EXIST -DUCT DETECTORS 100 M 12 12 - -- SPARE 16 illm 920 17 REC- GENERAL 720 R 12 H 200 EXIST-DAMPERS 18 19 SPARE -- - --- SPARE 20 r80 21 SPARE -- - - -� 12 - 12 R 180 EXIST -RTU RECEPT 22 23 SPARE -- - - - -- SPACE 24 r M 25 EXIST -AHU 672 H - - -- 26 67 r 7 � 27 672 -- - - -- 28 672 29 672 — - - -- 30 _ ' � 31 SPACE --- - -- - - -- 32 33 -- - - - - -- 34 35 -- - - - - -- 36 i 37 -- - - - __ � 38 39 -- - - -- - -- SPARE 40 41 i -- - - - - -- SPARE 42 SUB TOTALS 1 37121133021 3872 CONNECTED LOAD 10886 DEMAND LOAD 10886 DEMAND AMPERES 30.2 () QUAD RECEPTACLE O DEDICATED DBL DUPLEX FOR P.C. 4 • RETP MANAGERS DESKIACCESS POINT SCALE WE 0 NOT USED. 20 RUN 1" CONDUIT W /PULL SIRING FROM J -BOX ABOVE SALES /STOCK DOOR TO COMMUNICATIONS STRUCTURE 0 NOT USED. O NOT USED. 0 CASHWRAP DATA RUN 1" CONDUIT W /PULL STRING FROM COMM. STRUCT. TO MGRS DESK ALL CAT 3 AND CAT 5 WIRING, JACKS AND CONNECTIONS BY GUESS VENDORS. SEE CASHWRAP ELEVATION DETAIL SHEET E3.1. O GENERAL CONTRACTOR TO PROVIDE AND INSTALL 20A DOUBLE DUPLEX RECEPTACLE ISOLATED GROUND, ON DEDICATED CIRCUIT- ORANGE COLOR- FOR BACK OOICE PC (BOPC). 0 ACCESS POINT: GENERAL CONTRACTOR TO PROVIDE AND INSTALL DEDICATED CIRCUIT 20AMP /110VOLT J -BOX & DUPLEX RECEPTACLE FOR ACCESS POINT DIRECTLY ABOVE THE DOOR FROM CORRIDOR TO RETAIL FLOOR ON THE CORRIDOR SIDE (SEE POWER PLAN). RUN 1' CONDUIT TO DOMM. STRUCTURE. 0 UPS UNIT FOR COMPUTER. (BY OTHERS) 0 RUN 1" CONDUIT W /PULL STING FROM MANAGERS DESK TO TELEPHONE BOARD FOR FAX AND PHONE. USING SAME CONDUIT AS (PHONE JACK AT 42 ".) 10 UNDER COUNTER FLUORESCENT UGHT FIXTURE WITH SWITCH, SEE LIGHTING FIXTURE SCHEDULE PROVIDE FLEX CONDUIT TO HARD WIRE FIXTURE IN WALL BEHIND UPPER CABINET. 0 QUAD RECEPTACLE. EXIST 208V. 30, 100AS..100A.F. FOR RELOC. ROOFTOP UNIT TIMECLOCK FOR STOREFRONT NEW 3 p, 1 -1 /4,C TO TELEPHONE TERMINAL BOARD LOCATED IN COMM. STRUCTURE. - LOCATED IN STOCKROOM CEILING s / FLUORESCENT UGHT 0 FAX UNE / PHONE UNE O QUAD RECEPTACLE 0 NO TE ` RECEPTACLES SHOULD BE A MINIMUM OF 12" A.F.F. PANEL EXIST 208V. 30, 100A.S.,100A.F FOR RELOC. ROOFTOP UNIT • EXIST 2081. 30, 200A.S., 110AW. FOR RELOC. DUCT HEATER - -EXIST 208V, 30, 200A.S., 110AlF f - - — . ;EXIST CONDUIT 1 1 BY LANDLORD NEW 3 12 1 -1/4 "C FOR RELOC. DUCT HEATER EXIST �-� 4 1500 MCM PANEL EXIST 4 1500 MCIrt 2. E.C. SMALL FURNISH ALL NEW ELECTRICAL EQUIP. (PANELS. TRANSFORIYIEIt. CONDUIT, ETC.) AS REQUIRED, MESS NOTED OTHER 1. ALL %mtE SHALL BE COPPER ONMLY, THWI, THAI. THAN, OR NEC APPROVED EQUAL OR BETTER ALL WIRING SHALL BE IN CONDUIT. WIRE AMPACRY BASED ON NEC 110-14c AND TABLE 310-16. 1" CONDUIT TO COMM. STRUCTURE. 2 OUTLET ACCESS POINT STOCK ROOM SIDE OF THE WALL TO SALES FLOOR 1 i i ©O T/C T/C T/C T/C T/C 11 I 1 -----LEASE UNE ELEC1BCAL ONE-UNE DIAAM NCNB NOM EXIST 4 1500 MCM NOTE: ALL BREAKERS SHALL BE 20A 1 POLE BOLT -ON WITH 112 WIRE, UNLESS OTHERWISE NOTED. • - INDICATES THIS CIRCUIT TO RECIEVE HANDLE LOCK -ON CUP T/C - INDICATES THIS CIRCUIT TO BE CONTROLED BY A TIMECLOCK ROOF LINE FIELD VERIFY EXACT METER REQUIREMENTS 400AS. WITH 400A.F SERVICE FROM LANDLORD 120/208V, 30, 4W ELEC. DISTRIBUTION EQUIPMENT 3. ALL ELECTRICAL EQUIPMENT (PANELS, LIGHTS. [DEVICES,, CONDUIT, WIRE, ETC_) NOT BONG USED SHALL BE REMOVED FROM THE SIZE. DO NOT ABANDON IN PLACE. 4. E.C. SHALL FIELD VERIFY ALL EXISTING ELECTRICAL EQUIPM ENT. ALSO FIELD VERIFY THAT ANY EXISTING ELEC. EQUIPMENT TO BE REUSED IS OF ADEQUATE SIZE MO CONDITION TO IMJNINN SAFE OPERATION. W DISCREPANCIES ARISE CONTACT PROJECT REP. FLOOR LINE • (BUZZER) IN STOCKROOM CEILING (CHIME) IN STOCKROOM CEILING PUSH BUTTON AT R DOOR FOR BUZZER PUSH BUTTON IN WRAP FOR CHIME 6V TAP 114 CU IN 3/4 "C. TYPICAL TO ELECTRICAL PANEL OR CONNECT TO THE NEAREST AVAILABLE POWER TRANSFORMER IN STOCKROOM (BUZZER) IN CASH WRAP 114 C IN 3/4 " TO ELECTRICAL PANEL OR CONNECT TO THE NEAREST AVAILABLE POWER TRANSFORMER • NOTE ALL BREAKERS SHALL BE 20A 1POLE BOLT -ON WITH 112 WIRE, UNLESS OTHERWISE NOTED. • - INDICATES THIS CIRCUIT TO RECIEVE HANDLE LOCK -ON CUP T/C - INDICATES THIS CIRCUIT TO BE CONTROLED BY A TIMECLOCK 1. BUZZER RINGS AT CASHWRAP AND IN STOCKROOM FROM REAR DOOR. CHIME RINGS IN STOCKROOM FROM CAHSWRAP. 2. REFER TO SHEET E1.0, FOR ITEM CALLOUTS. O 3. SEE CASHWRAP DETAIL AND PLAN NOTES ON SHEET E3.1. BUZZER AND CHIME SCHEMAIIC WALE NONE .AJ(i 1 1 L607 REVIEWED FOR CODE COMPLIANCE 1 , iinnofuCI) on' 12 2006 I City Of Tukwila BUILDING DIVISION • RECEIVED CITY OF Ism �- SEP 212006 PERMIT CENTER a 1 i i 3'0 CUT OUT BY G.C. 0 4 PORTS, (2) DATA (2) VOICE TO COMM STRUCTURE 6' -0" () QUAD RECEPTACLE O DEDICATED DBL DUPLEX FOR P.C. 4 • RETP MANAGERS DESKIACCESS POINT SCALE WE 0 NOT USED. 20 RUN 1" CONDUIT W /PULL SIRING FROM J -BOX ABOVE SALES /STOCK DOOR TO COMMUNICATIONS STRUCTURE 0 NOT USED. O NOT USED. 0 CASHWRAP DATA RUN 1" CONDUIT W /PULL STRING FROM COMM. STRUCT. TO MGRS DESK ALL CAT 3 AND CAT 5 WIRING, JACKS AND CONNECTIONS BY GUESS VENDORS. SEE CASHWRAP ELEVATION DETAIL SHEET E3.1. O GENERAL CONTRACTOR TO PROVIDE AND INSTALL 20A DOUBLE DUPLEX RECEPTACLE ISOLATED GROUND, ON DEDICATED CIRCUIT- ORANGE COLOR- FOR BACK OOICE PC (BOPC). 0 ACCESS POINT: GENERAL CONTRACTOR TO PROVIDE AND INSTALL DEDICATED CIRCUIT 20AMP /110VOLT J -BOX & DUPLEX RECEPTACLE FOR ACCESS POINT DIRECTLY ABOVE THE DOOR FROM CORRIDOR TO RETAIL FLOOR ON THE CORRIDOR SIDE (SEE POWER PLAN). RUN 1' CONDUIT TO DOMM. STRUCTURE. 0 UPS UNIT FOR COMPUTER. (BY OTHERS) 0 RUN 1" CONDUIT W /PULL STING FROM MANAGERS DESK TO TELEPHONE BOARD FOR FAX AND PHONE. USING SAME CONDUIT AS (PHONE JACK AT 42 ".) 10 UNDER COUNTER FLUORESCENT UGHT FIXTURE WITH SWITCH, SEE LIGHTING FIXTURE SCHEDULE PROVIDE FLEX CONDUIT TO HARD WIRE FIXTURE IN WALL BEHIND UPPER CABINET. 0 QUAD RECEPTACLE. EXIST 208V. 30, 100AS..100A.F. FOR RELOC. ROOFTOP UNIT TIMECLOCK FOR STOREFRONT NEW 3 p, 1 -1 /4,C TO TELEPHONE TERMINAL BOARD LOCATED IN COMM. STRUCTURE. - LOCATED IN STOCKROOM CEILING s / FLUORESCENT UGHT 0 FAX UNE / PHONE UNE O QUAD RECEPTACLE 0 NO TE ` RECEPTACLES SHOULD BE A MINIMUM OF 12" A.F.F. PANEL EXIST 208V. 30, 100A.S.,100A.F FOR RELOC. ROOFTOP UNIT • EXIST 2081. 30, 200A.S., 110AW. FOR RELOC. DUCT HEATER - -EXIST 208V, 30, 200A.S., 110AlF f - - — . ;EXIST CONDUIT 1 1 BY LANDLORD NEW 3 12 1 -1/4 "C FOR RELOC. DUCT HEATER EXIST �-� 4 1500 MCM PANEL EXIST 4 1500 MCIrt 2. E.C. SMALL FURNISH ALL NEW ELECTRICAL EQUIP. (PANELS. TRANSFORIYIEIt. CONDUIT, ETC.) AS REQUIRED, MESS NOTED OTHER 1. ALL %mtE SHALL BE COPPER ONMLY, THWI, THAI. THAN, OR NEC APPROVED EQUAL OR BETTER ALL WIRING SHALL BE IN CONDUIT. WIRE AMPACRY BASED ON NEC 110-14c AND TABLE 310-16. 1" CONDUIT TO COMM. STRUCTURE. 2 OUTLET ACCESS POINT STOCK ROOM SIDE OF THE WALL TO SALES FLOOR 1 i i ©O T/C T/C T/C T/C T/C 11 I 1 -----LEASE UNE ELEC1BCAL ONE-UNE DIAAM NCNB NOM EXIST 4 1500 MCM NOTE: ALL BREAKERS SHALL BE 20A 1 POLE BOLT -ON WITH 112 WIRE, UNLESS OTHERWISE NOTED. • - INDICATES THIS CIRCUIT TO RECIEVE HANDLE LOCK -ON CUP T/C - INDICATES THIS CIRCUIT TO BE CONTROLED BY A TIMECLOCK ROOF LINE FIELD VERIFY EXACT METER REQUIREMENTS 400AS. WITH 400A.F SERVICE FROM LANDLORD 120/208V, 30, 4W ELEC. DISTRIBUTION EQUIPMENT 3. ALL ELECTRICAL EQUIPMENT (PANELS, LIGHTS. [DEVICES,, CONDUIT, WIRE, ETC_) NOT BONG USED SHALL BE REMOVED FROM THE SIZE. DO NOT ABANDON IN PLACE. 4. E.C. SHALL FIELD VERIFY ALL EXISTING ELECTRICAL EQUIPM ENT. ALSO FIELD VERIFY THAT ANY EXISTING ELEC. EQUIPMENT TO BE REUSED IS OF ADEQUATE SIZE MO CONDITION TO IMJNINN SAFE OPERATION. W DISCREPANCIES ARISE CONTACT PROJECT REP. FLOOR LINE • (BUZZER) IN STOCKROOM CEILING (CHIME) IN STOCKROOM CEILING PUSH BUTTON AT R DOOR FOR BUZZER PUSH BUTTON IN WRAP FOR CHIME 6V TAP 114 CU IN 3/4 "C. TYPICAL TO ELECTRICAL PANEL OR CONNECT TO THE NEAREST AVAILABLE POWER TRANSFORMER IN STOCKROOM (BUZZER) IN CASH WRAP 114 C IN 3/4 " TO ELECTRICAL PANEL OR CONNECT TO THE NEAREST AVAILABLE POWER TRANSFORMER • NOTE ALL BREAKERS SHALL BE 20A 1POLE BOLT -ON WITH 112 WIRE, UNLESS OTHERWISE NOTED. • - INDICATES THIS CIRCUIT TO RECIEVE HANDLE LOCK -ON CUP T/C - INDICATES THIS CIRCUIT TO BE CONTROLED BY A TIMECLOCK 1. BUZZER RINGS AT CASHWRAP AND IN STOCKROOM FROM REAR DOOR. CHIME RINGS IN STOCKROOM FROM CAHSWRAP. 2. REFER TO SHEET E1.0, FOR ITEM CALLOUTS. O 3. SEE CASHWRAP DETAIL AND PLAN NOTES ON SHEET E3.1. BUZZER AND CHIME SCHEMAIIC WALE NONE .AJ(i 1 1 L607 REVIEWED FOR CODE COMPLIANCE 1 , iinnofuCI) on' 12 2006 I City Of Tukwila BUILDING DIVISION • RECEIVED CITY OF Ism �- SEP 212006 PERMIT CENTER a Pro jeCt Info ss aoess 9/19/2004 os swam= n¢:. DIM aus OReadegOerbrnentUse 7wRna. us suss _POiai nos comb apericat4Adees= sass sams b_ suss 70.. ,T_ ZOOM MD See Weed FM= emus-nos Ihoject Description 1ta aussap Q D > Qum biasses bWSECSousa t313 for oonevbarst= sxi%sup roar . IC Opdoi IOtoesaioc a Ot•4g Posy Mpranoe O rise otiaresetedislOwe) r e feslartetatsfsettMkspeoesde .Araisms) apprapl*bar.$e IIJ2.3 I❑ abdopesas 1 n om. was+ e ti�sssne" .: sta6ea .wpr d I9ed tecafos Olscoo rs Aassent Its Pe eel taeS Aete;m for it,ry....I.l Jambe bat 1 0 42 4 1 ES Cessiet Saws oraftsms pea mat El E eased Palm •sttea.e mei 2 31114 Otte Panay 22 MA - 0 a , 3 oei9forisse e i 02701s t r . aft flybad - 02511l ;i ow .,_f sssw 1. DMON 16 - ELECTRICAL SPEI9CA11ONS SECTION nao eECTwcni_ SPECIAL CONDITIONS BEM& A. APPLICABLE PROVISIONS OF NA DOCUMENT A201, "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION", AND DMSION 1 GENERAL CONDITIONS GOVERN WORK UNDER THIS SECTION AND ALL OTHER SECTIONS OF DMSION 16. B. APPLICABLE PROVISIONS OF THIS SECTION GOVERN WORK UNDER ALL OTHER SECTIONS OF DIVISION 16. WORK COVERED BY MIS SECTION SHALL CONSIST OF PROVIDING ALL MATERIAL, LABOR, EQUIPMENT AND SERVICES NECESSARY FOR A COMPLETE, TESTED AND ADJUSTABLE ELECTRICAL INSTAlATLON READY FOR OPERATION AS SPECIFIED HEREIN AND AS SHOWN ON THE DRAWINGS. C. THE TERM CONTRACTOR AS USED IN THIS SECTION SHALL MEAN ANY CONTRACTOR OR SUBCONTRACTOR WHO HAS CONTRACTED TO PERFORM WORK INCLUDED IN AND DEFINED BY 111IS SECTION AND ALL OTHER SECTIONS OF DMSION 16. 2. SIMBACIORIAESPINEKTI A PRIOR TO SUBMITTING HIS BID, CONTRACTOR SHALL CAREFULLY EXAMINE THESE CONSTRUCTION DOCUMENTS, THE DEVELOPER'S EXHIBITS, AND THE SITE, TO INQUIRE FULLY INTO DIFFICULTIES AND COSTS OF WORK, AND TO DETERMINE THE SCOPE AND CHARACTER OF WORK TO BE DONE. CONTRACTOR SHALL INCLUDE ALL NECESSARY COSTS TO LOCATE AND /OR EXTEND ALL UTILITIES INCLUDING UGHTiNG PANELS, POWER PANELS, ELECTRICAL SERVICE. PHONE SERVICE AID /OR MODIFY EQUIPMENT TO MEET THE INTENT OF THE CONTRACT DOCUMENTS. THE OWNER. OWNER'S AGENT, ARCHITECT, ENGINEER OR DESIGNER SHALL NOT BE RESPONSIBLE FOR FAILURE OF THE CONTRACTOR TO DETERMINE DIFFICULTIES AND COSTS IN THE PROJECT OR FOR HiS OVERLOOKING OF THE REQUIREMENTS. B. IF THIS CONTRACTOR DOES NOT CLEARLY UNDERSTAND THE PLANS AND SPECIFICATIONS, OR IF THERE ME ANY REQUIREMENTS WHICH ARE AMBIGUOUS IN THE CONTRACTOR'S OPINION. HE SHOULD CALL THiS TO THE ATTENTION OF THE ARCHITECT PRIOR TO BIDDING, SINCE THIS CONTRACTOR WILL BE HEW RIGIDLY TO THE INTERPRETATIONS OF THE ARCHITECT AND ENGINEER. C. CONTRACTOR SHALL SCHEDULE HIS WORK IN COOPERATION WITH OTHER TRADES INSTALLING INTERRELATED WORK. ALL WORK SHALL BE SCHEDULED TO MAINTAIN SERVICE TO ALL REQUIRED AREAS DURING THE COURSE OF THE CONSTRUCTION EXCEPT FOR SHORT TERM PLANNED SHUTDOWNS. ANY OF WHICH SHALL BE PRE - SCHEDULED WITH THE OWNERS AGENT AND THE LANDLORD. 3. NOBIONISILMOSUARAMIEE A. IN ENTERING INTO A CONTRACT COVERING THIS WORK, THE CONTRACTOR ACCEPTS THE SPECIFICATIONS. AND GUARANTEES THAT THE WORK WILL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. CONTRACTOR FURRIER GUARANTEES THAT THE WORKMANSHIP AND MATERIAL WILL BE OF THE BEST PROCURABLE AND THAT NONE BUT O(PERIENCED WORKMEN DXPERIENCED IN EACH PARTICULAR CLASS OF WORK WILL BE EMPLOYED. CONTRACTOR FURTHER GUARANTEES TO REPLACE AND MAKE G00D AT HIS OWN EXPENSE ANY DEFECTS DUE TO FAULTY WORKMANSHIP OR MATERIAL WHICH MAY DEVELOP WITHIN ONE (1) YEAR AFTER FINN. PAYMENT AND ACCEPTANCE BY THE ARCHITECT. 4. A. CONTRACTOR WILL COMPLY IN ALL RESPECTS WITH THE ADOPTED BUILDING CODES, APPLICABLE LAWS. ORDINANCES. AND REGULATIONS AS MAY APPLY ACCORDING TO THE RULING OF THE CONTROWNG PUBLIC OFFICIAL SHOULD THE CONTRACTOR PERFORM ANY WORK THAT DOES NOT COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE LAWS. ORDINANCES AND REGULATIONS, OR WHICH DOES NOT RECEIVE THE APPROVAL OF THE CONTROLLING PUBLIC OFFICIAL HE SHALL BEAR ALL COSTS ARISING IN CORRECTING THE DEFICIENCIES. ALL ELECTRICAL EQUIPMENT SHALL SHALL BEAR THE UNDERWRiTER''S LABORATORY LIBEL. 5. FEES aN PEAIAf1S A. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND MAKING PAYMENT FOR ALL FEES, PERMITS AND INSPECTIONS RELATING TO HIS WORK. a .IIMBEGLOBAImOS A. THE DRAWINGS SHOW THE GENERAL ARRANGEMENT AND INTENT OF THE DESIGN AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONDITIONS AND THE WORK OF OTHER TRADES WILL PERIiN. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS. IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS. ANO ACCESSORIES WHICH MAY BE REQUIRED. NOR IS IT IMPLIED THAT ALL CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE SYSTEMS OR BUILDING COMPONENTS HAVE BEEN INDICATED. THE CONTRACTOR SHALL INVESTIGATE ALL EXISTING CONDITIONS AFFECTING THE WORK AND ARRANGE HIS WORK ACCORDINGLY, PROVIDING SUCH FITTINGS. OFFSETS, ACCESSORIES AND DEVICES AS MAY BE REQUIRED. THE DRAWINGS AND SPECIFICATIONS ARE RITUALLY COMPLEMENTARY, AND ANY WORK REQUIRED BY ONE BUT NOT BY THE OTHER SHALL BE PERFORMED BY BOTH. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PRUNING ALL MATERIALS AND SERVICES REQUIRED FOR A COMPLETE AND WORKING PROJECT AT NO ADDITIONAL COST EVEN THOUGH EACH AND EVERY NECESSARY ELEMENT THEREOF IS NOT SPECIFICALLY IDENTIFIED HEREIN EACH AND EVERY NECESSARY ELEMENT THEREOF IS NOT SPECIFICALLY IDENTIFIED HEREIN. B. CONTRACTOR SHALL NOT SCALE FROM THE DRAWINGS BUT SHALL FOLLOW THE ARCHITECTURAL DRAWINGS OR DISHING BUILDING CONDITIONS WHERE APPLICABLE, IN ESTABLISHING DIMENSIONS AND LNIES OF RUN, SINCE DIMENSIONS ON THE FINAL ARCHITECTURAL DRAWINGS OR AT THE SHE MAY NOT COINCIDE ODE WiTH THOSE SHOWN ON THE ELECTRICAL DRAWINGS, THE CONTRACTORS SHALL VERRWY WITH THE DIMENSIONED ARCHITECTURAL DRAWINGS OR THE SITE CONDITIONS THE EXACT MATERIAL QUANTITIES AND LENGTHS NECESSARY_ C. SIGNIFICANT DEVIATIONS OR CHANGES FROM THE DRAWINGS WHICH ARE REQUIRED TO ACCOMPLISH THE INTENT OF THE CONTRACT DOCUMENTS MUST BE REVIEWED WITH THE ARCHITECT AND APPROVED BEFORE PROCEEDING. 7. SWUM= AMt A. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS. FOUR (4) COPIES MINIMUM, FOR ALL MANUFACTURED PRODU CTS. EACH SHOP DRAWING SHALL BE REVIEWED BY TIE CONTRACTOR PRIOR TO SUBMITTAL TO ASSURE THAT ALL DIMENSIONS. QUANTITIES,. CONNECTIONS, CAPACITATES AND ACCESSORIES SHOWN ARE N CONFORIUINCE WITH THE CONTRACT DOCUMENTS, AND SHAT BE MARKED OR STAMPED TO CONFIRM THAT SUCH REVIEW WAS MADE AND COMPLANCE WAS COED. B. APPROVAL OF SHOP OR/WINGS BY THE OWNER, OWNER'S AGENT, ARCHITECT, ENGINEER OR DESIGNER. WiLL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBIUTY OF COMPLYING WITH ML TERMS OF THE CONTRACT DOCUMENTS. TIE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR PERFORMANCE OF EQUIPMENT PURCHASED. FOR PROPER FIT. MID OTHER DIMENSIONAL REQUIREMENTS. b BEMBELEIBMEGS A. CONTRACTOR SHALL MARTIAN AT THE JOB SITE ONE SET OF DOCUMENTS AS 'RECORD DRAWINGS' FOR THE PURPOSE OF DAILY MARKING OF ILL SUBSTANTIAL REVISIONS TO THE COMMENTS INCLUDING BUT NOT LISTED TO ELECTRICAL CHANGES. ARID LOCATIONS OF UiRITES, PANELBOARDS. DISCONNECTS, STARTERS AD OTHER DEVICES REQUIRING PERIODIC OPERATIONAL ATTENTION, ADJUSTMENT. OR SERVICE INCLUDING ACCESS THERETO. AT THE COMPLETION OF THE PROJECT, THUS SET SHALL BE RETURNED TO THE ARCHITECT FOR THE PURPOSE OF MAKING NG FNN 'AS -BGCLT OWIWMINGS'. A A. SPECFiC MANUFACTURERS MD MODELS OF EQUPMENT HAVE BEEN USED N THE DEVELOPMENT OF THE ORAiI NGS MD DESIGNS. MI5 CONTRACTOR MUST SUBMIT TO TIE OWNER ANY CHANGES AM /OR SUBSTITUTIONS FOR APPROVAL PRIOR TO IISTALLAIION OR EXECUTION. ANY CHANGES WHICH DO NOT RECEIVE THE OWNERS APPROVAL MAY BE SUBJECT TO REMOVAL OR REPiJYCOIENT AS ORIGINALLY SPECIFIED. MD WILL BE AT THE CONTRACTOR'S EXPENSE. a B. IF THIS CONTRACTOR SUBSTITUTES FOR SPECIFIED EQUIPMENT ANY OTHER EQUIPMENT WHICH REQUIRES MY CHANGES TO THE DESIGN, ALL COST OF REDESIGN AND RECONFIGURATION RESULTING TING FROM SAiD SUBSTITUTION SHALL BE BORNE BY THE SUBMITTING CONTRACTOR. 10. A. CONTRACTOR SHALL SUPPORT PLUMB. RIGID AND TRUE TO -LNE ALL WORK AND EQUIPMENT INSTALLED. THIS CONTRACTOR SHALL DETERMINE HOW EQUIPMENT, FIXTURES. ETC.. ME TO BE SUPPORTED, MOUNTED, OR SUSPENDED MID SHALL PROVIDE ACCESSORIES REQUIRED FOR PROPER SUPPORT WHETHER SHOWN ON THE DRAWINGS OR NOT. IF SUPPORTS ARE REQUIRED. CONTRACTOR SHALL SUBMIT DRAWINGS TO THE ARCHITECT FOR APPROVAL B. PRODUCTS SHALL BE INSTALLED IN ACCORDANCE WiTH MANUFACTURERS PRINTED INSTALLATION AND MAINTENANCE LITERATURE. COMPONENTS REQUIRING PERIODIC MAINTENANCE OR ADJUSTMENTS SHALL BE LOCATED OR INSTALLED AS TO PERMIT ACCESS WITHOUT DAMAGE TO STRUCTURE, FINISHES OR OTHER EQUIPMENT. C. AU. CONDUIT CONNECTING TO SWITCHGEAR, PANELS, MOTORS, AND OTHER EQUIPMENT SHALL BE INSTALLED WITHOUT STRAIN AT THE CONNECTIONS. THE CONTRACTOR MAY BE REQUIRED, AS DIRECTED. TO DISCONNECT CONDUITS TO DEMONSTRATE THAT THEY HAVE BEEN SO CONNECTED 11. A. ALL CUTTING THAT MAY BE NECESSARY FOR THE INSTALLATION OF THE WORK OR ANY REQUIRED PATCHING THAT RESULTS THEREFROM SHALL BE DONE BY THE PROPER TRADE INVOLVED AND SWILL. BE INCLUDED AS PART OF THIS CONTRACT. PATCH TO DUPLICATE UNDISTURBED ADJACENT FINISHES. COLORS, TEXTURES AND PROFILES. COLUMNS. BEAMS, GIRDERS OR JOISTS SHALL NOT BE CUT. 8. ALL. WORK AFFECTING ROOF OR STRUCTURES SHALL BE PERFORMED BY LANDLORD'S CONTRACTOR AT TENANT'S CONTRACTOR EXPENSE. 12. .2E A. COMPLETION AS IT PERTAINS TO THE CONTRACT COMPLETION DATE iS DEFINED AS THE DAY THE PROJECT IS TURNED OVER TO THE OWNER IN THOROUGHLY CLEAN CONDITION. READY FOR THE OWNER TO TAKE POSSESSION. ALL FIXTURES. MOTORS, EQUIPMENT AND ALL OTHER ELECTRICAL EQUIPMENT FURNISHED OR INSTALLED BY THE CONTRACTOR SHALL BE THOROUGHLY CLEANED. 13. MIS A. PROVIDE THE TESTS AS OUTLINED HEREINAFTER AND OTHER TESTS NECESSARY TO ESTABLISH THE ADEQUACY, QUALITY, SAFETY, COMPLETED STATUS MD SUITABLE OPERATION OF EACH SYSTEM. CORRECT PROMPTLY ANY FAILURE OR DEFECTS REVEALED BY THESE TESTS AND RECONDUCT TEST ON THE CORRECTED ITEMS. B. TEST THE GROUNDS WITH A GROUND RESISTANCE DIRECT READING SINGLE -TEST MEGGER. C. INSULATION RESISTANCE BETWEEN PHASE CONDUCTORS MID GROUND NOT LESS THAN 1,000,000 OHMS. D. THE PANELBOARDS SHALL HAVE PHASE CURRENTS BALANCED TO WITHIN +/- 10X VARIATION BETWEEN AVERAGE PHASE CURRENT AND MEASURED INDIVIDUAL PHASE. E. AN OPERATIONAL TEST OF THE EMERGENCY LIGHTS AND THE EXIT LIGHTS SHALL BE PERFORMED FOR THE OWNER TO DDAONSiRATE CONFORMANCE TO THE SPECIFICATIONS. A. TEMPORARY EI EC1RiCAL SERVICE SHALL BE IN ACCORDANCE WITH THE BUILDING CODE TEMPORARY LIGHTING SHALL BE PROVIDED BY A LAMP LOCATED FOR EVERY 625 SQUARE FEET OF BUILDING AREA WITH A MINIMUM OF ONE PER ROOM. THE LAMP TO BE 100 WATT AND SHALL BE MAINTAINED BY THE GENERAL CONiRACiOR. B. TEMPORARY POWER DISTRIBUTION SHALL BE SUFFICIENT TO ACCOMMODATE THE TEMPORARY UGH TING AND CONSTRUCTION OPERATIONS, INCLUDING THE USE OF POWER TOOLS (BUT NOT INCLUDING HEAVY -DUTY ELECTRICAL WELDING UNITS). ELECTRICAL HEATING UNITS, AND START -UP OF SPECIFIED BUILDING EQUIPMENT, WHICH iS TO BE TESTED, STARTED OR PLACED INTO OUR USE PRIOR TO COMPLETION OF RS PERMANENT POWER CONNECTIONS. 15. EXCONIELNIILMBILL A. CONTRACTOR SHALL DO ALL EXCAVATION REQUIRED AS SHOWN ON PLANS OR REQUIRED FOR PROPER OPERATION. EXCESS EXCAVATION BELOW THE REQUIRED LEVEL SHALL BE BACKFIELD WITH EARTH AND THOROUGHLY TAMPED. UTILITY SERVICES, SHALL BE INSPECTED AND APPROVED BY THE PROPER INSPECTION AUTHORITY BEFORE BAcKFUJNG. SWIM 16200 ELECTRICAL POWEFT APD U01111NCi 1. numunaseas A. APPLiCJABLE PROVISIONS OF AA DOCUMENT A201, 'GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION'. DIVISION 1 GENERAL CONDITIONS MD SECTION 16100 ELECTRICAL SPEC2AL CONDITIONS GOVERN WORK UNDER THIS SECTION. B. REFER TO SECTION 16100 ELECTRICAAL SPECIAL. CONDITIONS REGARDING REGULATIONS AND REQUIREMENTS AFFECTING ALL WORK DESCRIBED IN THIS SECTION. 2. ZUMILSUBICE A. POWER SERVICE FOR THRS PROTECT SHALL BE PROVIDED FROM THE EXISTING MALL DISTRIBUTION SYSTEM. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MALL MANAGEMENT TO INSURE THAT ALL WORK AND MATERIALS ARE N CONFORIONCE WITH THE LANDLORD'S REQUIREMENTS. 3. A. ELECTRICAL EQUIPMENT, INCLUDING BUT NOT UNTIED TO. PANO.BIW S, DISCONNECTS CONTROLS, ETC., SHALL BE IDENTIFIED WITH THREE LAMINATED PLASTIC. THE OUTSIDE LAMINATIONS SHALL BE BLACK ENGRAVING SHALL EXTEND THROUGH THE FRONT LAI NATION SO THAT THE BLACK LETTERS APPEAR ON A WHITE BACKGROUND. NAMEPLATES SHALL BE PERMANENTLY ATTACHED WITH SCREAMS. D CIRCUIT DIRECTORY SHALL BE TYPEWRITTEN (HADNRRITTEN IS NOT ACCEPTABLE) AND SHALL D ENi1FY 1f NT AS TO TYPE AND LOCATION AS FOLLOWS: 'LTG' - FOR LIGHTING CIRCUIT FOLLOWED BYl AREA N WHICH MINT APPEARS, LE, 'STOGQROOMP. 'CASH WRAP; ETD "REC1Pr - FOR RECEPTACLE CIRCUIT FOLLOWED BY AREA N WHICH RECEPTACLE APPEARS, "STOREFRONT; 'CASH REGISTER, ETC. 'MOTOR.' - FOR MOTOR FOLLOWED BY THE EQUIPMENT DENTFICATiON AND AREA IN WHICH MOTOR IS LOCATED, I.E. "Dal FAN TOILET', 'AHU- ROOF', ETC. 4. Magi A. ALL SONG SHALL BE RUN N CONDUIT THAI WALL OfT COt'DU T SHALL BE USED SUES 1/2' THROUGH 2 -1 /2 ALL CONDUITS URGER THAN 2 -1/2" SHALL BE NEMMIML CONDUITS INSTALLED UNDERGROUND OR N CONCRETE SCABS SHALL BE RIC JACICETED FLEXIBLE STEEL CONDUIT (SEALTITE) SHALL BE USED N WET AREAS MD ON ML MOTORIZED EQUIPMENT. FUMBLE CONDUIT MAY ONLY BE USED FOR FINAL coreecnoes. AT A YA IN NUMN LENGTH OF 6 FEET. NO BX, ROAM ARMORED CABLE, ETC` SIMLL BE ALLOWED. • & WIRE AND CABLE A. ALL WIRE AND CABLE SHALL BE RUN N CONDUIT. ALL WIRE AND CABLE FEEDERS AND BRANCH CIRCUITS SHALL CONFORM TO THE LATEST REQUIREMENTS OF THE CURRENT EDITION OF THE N.E.C. AND SHALL MEET ALL ASTM SPECiFICATK INS. WIRE AND CABLE SHALL BE NEW, SHALL HAVE SIZE, GRADE OF INSULATION VOLTAGE AND MANUFACTURER'S NAME PERMANENTLY MARKED ON OUTER COVERING AT REGULAR INTERVAL AND SHALL BE DELIVERED IN COMPLETE COILS OR REELS WITH IDENTIFYING SiZE AND INSULATION TAGS. 6. =nun= A. A COLOR CODING SYSTEM AS LISTED BELOW SHALL BE FOLLOWED THROUGHOUT FOR FEEDERS MD BRANCH CRCUITS AND USED AS A BASIS FOR BALANCING LOAD. 9. B. ALL OPENINGS IN FIRE AND SMOKE WALLS, PARTITIONS, FLOORS AND OTHER SIMILAR PENETRATIONS FOR ELECTRICAL CONDUITS, CABLE OR EQUIPMENT, WHETHER CUT OR IN PLACE, SHALL BE CLOSED WiTH A UL APPROVED FIRE RESISTANT SILICONE FOAM SEALANT TO MAINTAIN THE FULL RATING AND INTEGRITY OF THE PARTITIONS, WALLS OR FLOOR. C. CONDUIT BENDS FOR POWER AND LIGHTING CIRCUITS SHALL NOT BE LESS THAN STANDARD RADIUS BENDS. CONDUIT BENDS FOR FEEDERS. TELEPHONE AND COMMUNICATION CIRCUITS SHALL NOT BE LESS THAN LONG RADIUS BENDS. D. 02. TYPE DX, TX, OR AX CONDUIT EXPANSION DEFLECTION FITTINGS ARE REQUIRED IN ALL CONDUIT RUNS WHERE MOVEMENT MAY BE ENCOUNTERED. ALL EMT COUPLINGS SHALL BE COMPRESSION TYPE. E. EXPOSED CONDUIT SHALL BE SECURELY SUPPORTED IN PLACE PER CODE BUT ON A MAXIMUM OF 10 FOOT INTERVALS, WUHN THREE FEET OF EACH BEND, AT EVERY OWLET OR JUNCTION BOX AND AT THE END OF EACH STRAIGHT RUN TERMNATNG AT A BOX OR CABINET. CONDUIT SHALL NOT BE SUPPORTED FROM DUCTWORK OR PIPE WORK. CONDUITS SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO THE BUILDING LINES. GENERALLY, CONDUIT SHALL BE RUN IN CONTACT WITH STRUCTURAL PARTS OF THE BUILDING SO AS TO AVOID SUSPENDED LENGTHS OF CONDUIT. CONDUIT SHALL BE INSTALLED AS TO BE ACCESSIBLE FOR REPLACEMENT AND MAINTENANCE AND GENERALLY CONDUIT SHALL BE INSTALLED TO PERMIT DRAINAGE. 8. THE ELECTRICAL CONTRACTOR SHALL CALCULATE VOLTAGE DROP ON CONDUCTORS WITH LENGTHS GREATER THAN 75 FEET FROM THE PANELBOARD AND PROPERLY SIZE THE CONDUCTORS PER N.E.C. C. POWER CONDUCTORS: NO WIRE LESS THAN NO. 12 SHALL BE USED EXCEPT FOR CONTROL CIRCUITS OR LOW VOLTAGE WIRING. WIRE SIZES NO. 12 TO NO. 10 SHALL BE SOLID EXCEPT WHERE OTHERWISE INDICATED. WIRE SUES NO. 8 AND LARGER SHALL BE STRANDED. ALL WIRE SIZES SHOWN ARE AMERICAN WIRE GAUGE SIZES. SIZES NO. 12 AWG THROUGH NO. S AWG SHALL BE 'THEW." SIZE 4 AWG AND LARGER SHALL BE 'T HW.' D. CONTINUITY: ALL WIRES SHALL BE CONTINUOUS FROM OUTLET TO OUTLET. E. ACCEPTABLE MANUFACTURERS: CABLE AND WIRE SHAT BE STANDARD TYPE AS MANUFACTURED BY GENERAL CABLE COMPANY, CAROL, ANACONDA, ROM OR ITT ROYAL --- 120 /206V: PHASE A-- BLACK, PHASE B- -RED. PHASE C- -BLUE, NEUTRAL -- WHITE. GROUND--GREEN -- 277 /480V: PHASE A-- BROWN. PHASE B-- ORANGE, PHASE C-- YELLOW, NEUTRAL- -GRAY, GROUND- -GREEN 7. A. ALL OUTLETS SHALL BE PROVIDED WITH GALVANIZED OR SHERARDiZLD BOXES SUITABLE IN DESIGN TO THE SPACE THEY OCCUPY AND THE PURPOSE THEY SERVE. WALL MOUNTED OUTLET BOXES, EXCEPT FOR 2' PARTITIONS SHALL BE AT LEAST 1 1/2' DEEP AND/OR DEEPER IF REQUIRED BY THE DEVICE THEY HOLD OR THE NATIONAL ELECTRICAL CODE. B. ALL PULLBOXES SHALL BE MADE OF GALVANIZED STEEL, OF METAL GAUGE AND PHYSICAL SUE AS REQUIRED BY THE NEC FOR THE NUMBER AND SIZE OF RACEWAYS AND CONDUCTORS INVOLVED. C. FIXTURE OUTLET BOXES IN OR ON CEILINGS SHALL NOT BE LESS MAN 1 -1/2' DEEP OR LESS THAN 4' SQUARE. ALL OUTLET BOXES INTENDED TO SUPPORT FIXTURES SHALL BE EQUIPPED WITH 3/8' FIXTURE STUDS FASTENED THROUGH THE 80170M OF THE BOX WITH FOUR BOLTS. 8. LICIILINIFIEEILPAELOMS A. PANELS SHALL BE DEAD FRONT, SAFETY TYPE, FURNISHED WITH BRANCH CIRCUIT PROTECTING DEVICES, EQUIPMENT GROUNDING BOX, MAIN BUS AND CABLE LUGS FACTORY ASSEMBLED. WITH ALL COMPONENTS IN PLACE, READY FOR INSTALLATION. PROVIDE 20% SPARE BREAKER CAPACITY AND 25% EXCESS AMPACiTY IN EACH PANEL B. CURRENT CARRYING CONTACT SURFACES SHALL BE SILVER OR TIN PLATED. THE CIRCUIT BREAKERS SHALL BE OF THE MOLDED CASE, BOLT -ON TYPE SUITABLE FOR VOLTAGE AND AMPERE RATINGS INDICATED ON DRAWINGS AND IN SCHEDULES AND SHALL HAVE A MINIMUM INTERRUPTING CAPACITY OF 10.000 AMPERES FOR 120 /206V AND 14.000 AMPERES AT 277/48011. C. MAIN BUSES AND CONNECTORS SHALL BE HARD DRAWN COPPER OF 98% CONDUCTMiY, WITH CURRENT CARRYING CAPACITY TO MAINTAIN ESTABLISHED RISE TESTS AS DEFINED IN UL STANDARD UL 67. D. CABINET SAES ARE BASED UPON A 20' WIDE BY 6' DEEP PANEL UNLESS OTHERWISE NOTED. PMNELBOARDS SHALL BE EQUIPPED WITH FLUSH TYPE LOCK AND CATCH. ALL LOCKS SHALL BE KEYED ALIKE, AND TWO KEYS ARE TO BE SUPPLIED WITH EACH LOCK. E. PANELBOARDS TO BE BY SQUARE D CORPORATION, GENERAL ELECTRIC, OR SIEMENS. BffigiagaBS A. DRY -TYPE TRANSFORMERS SHALL BE OF THE ENCLOSED VENTILATED TYPE WITH KVA MD VOLTAGE RATING AS CALLED FOR ON THE DRAWINGS AND WITH 150' CLASS H INSULATION AND MINIMUM OF SIX STANDARD FULL CAPACITY TAPS. SOUND LEVEL SHALL BE LOW AND INSTALLATION SHALL INCLUDE KORFUND OR EQUAL VIBRATION DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY. (MOUNT TRANSFORMER ON VIBRATION ISOLATORS). LOCATE TRANSFORMER AS NOT TO CAUSE SERVICING OR CLEARANCE DIFFICULTIES OF VIOLATIONS WITH OTHER EQUIPMENT. • COMPARABLE EQUIPMENT AS MANUFACTURED BY SQUARE CORPORATION OR GENERAL ELECTRIC 10. infitaLSMOIS A. TOGGLE SWITCHES SHALL BE WHITE AND SHALL BE RATED 20 AMPERES 120 /277 VOLT AC TYPE AS MANUFACTURED BY HUBBELL AND SHALL BE AS FOLLOWS: SINGLE POLE -- 1221 - -1 THREE WAY -- 1223 - -1 B. TOGGLE SWITCHES SHALL BE MOUNTED 4'-0' ABOVE FINISHED FLOOR TO MOUNTING PLATE AND, AT DOORS, mu m° ADJACENT TO THE TRIM ON THE STRIKING SIDE OF THE DOOR, REGARDLESS OF THE LOCATION NDICATED ON THE DRAWINGS; THEREFORE, CHECK ALL DOOR SWINGS BEFORE INSTALLATION OF CONDUIT OUTLETS. C. COMPARABLE EQUIPMENT AS MAMUFACRURED BY RATER, LEVITON, AND BRYANT WILL BE ACCEPTABLE 11. A. RECEPTACLES SHALL BE WHITE AS MMFJFACTURED BY HUBBEL AND SHALL BE AS FOLLOWS: DUPLEX RECEPTACLE --20A-120 VOLT 5362 -1 EL RECEPTACLES SHALL BE MOUNTED 12' ABOVE THE FNStED FLOOR UNLESS OTHERWISE NOTED. C. COIRAiABLE EQUIPMENT AS MAMIFACRIRED BY SERRA ELECTRIC CORPORAiIONN, SLATER BRYANT AHD LEMTON WILL BE ACCEPTABLE. • 12. DEMSLELMES A. DEVICE PLATES SHALL BE WHITE UNLESS OTHERWISE NOTED. COMPARABLE EQUIPMENT AS MANUFACTURED BY SIERRA ELECTRIC CORPORATION, HARVEY HUDDLE INC., BRYAiNT AND LEVITON WiI.L BE ACCEPTABLE. PANT MATCH ADJACENT FINISH COLOR. 13. DISMERIECUMGES A. FURNISH AND INSTALL DISCONNECT SWITCHES AS REQUIRED BY CODE. DISCONNECT SWITCHES SHALL BE NEMA HEAVY DUTY TYPE AND UNDERWRITERS LABORATORIES LISTED. MANUFACTURED BY SQUARE D CORPORATION, ITE, GENERAL ELECTRIC, OR WESTINGHOUSE. 14. MAIM A. CONTRACTOR SHALL INSTALL A SYSTEM GROUNDING SYSTEM AND AN EQUIPMENT GROUNDING SYSTEM AND SHALL USE ONLY APPROVED GROUNDING CLAMPS AND CONNECTORS AS MANUFACTURED BY PENN -UNION, BURNDY, OR 0-Z MFG. COMPANY. B. THE SYSTEM GROUNDING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND THE UTILITY COMPANY REGULATIONS. CONTRACTOR SHALL CONNECT THE GROUNDING ELECTRODE CONDUCTORS TO THE NEUTRAL BAR INSIDE THE MAIN PANEL WHEN TRANSFORMERS ARE USED TO PROVIDE A SEPARATELY DERIVED SYSTEM, THE CONTRACTOR SHALL CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE NEUTRAL BAR INSIDE THE SECONDARY SYSTEM PANEL OR SERVICE RATED DISCONNECT SWITCH, DO NOT CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE NEUTRAL LUG INSIDE THE TRANSFORMER. 18. C. THE EQUIPMENT GROUNDING SYSTEM SHALL CONSIST OF A CONTINUOUS CONDUIT INSTALLATION AND A GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR. THIS GROUNDING CONDUCTOR SHA 1. BE INSTALLED IN EVERY CONDUIT OR RACEWAY WITH THE FEEDER OR BRANCH CIRCUIT CONDUCTORS. THIS GROUNDING SHALL BE EXTENDED FROM THE HOUSING OF EVERY ELECTRICAL LOAD, THROUGH PANELBOARD STATIC GROUNDING BUSSES, TO THE STATIC GROUNDING BUS N THE MAIN PANEL. THE GROUNDING BUS SHALL BE BONDED TO THE GROUNDING NEUTRAL BAR INSIDE THE MAIN PANEL 15. LIMMIGIDMIMB A. ALL LIGHTING FIXTURES AND LAMPS SHALL BE FURNISHED BY OWNER, UNLESS NOTED OTHERWISE. THIS CONTRACTOR Stall INSTALL LIGHTING FIXTURES AND LAMPS AS INDICATED ON THE DRAWINGS AND AS SPECIFIED BELOW, COMPLETE WITH HANGERS. PLASTER FRAMES AND ALL OTHER NECESSARY ACCESSORIES. B. ALL BALLAST. STARTERS AND LAMPHOLDERS IN FLUORESCENT LIGHTING EQUIPMENT ARE TO BE ELECTRICAL TESTING LABORATORIES, UNDERWRITERS LABORATORIES AND CERTIFIED BALLAST MANUFACTURERS APPROVED. ALL BALLAST FOR FLUORESCENT RXRIRES SHALL BE OF THE HIGH POWER FACTOR TYPE AND SHALL BE GENERAL ELECTRIC 'MAXI -MISER II' OR ADVANCED MARK III. WHERE OCTRON LAMPS ME SPECIFIED PROVIDE APPROPRIATE BALLASTS. C. THIS CONTRACTOR SHALL VERIFY THE FINAL CEILING AND FiNISH SCHEDULES TO INSURE THE PROPER INSTALLATION AND MOUNTING OF FIXTURES AND SHALL COORDINATE BEFORE MAKING SUBMITTALS. 16. A. TIMECLOCKS SHALL BE 24 HOUR. 7 DAY , DAY SKIPPER TYPE AS MANUFACTURED BY TORK, INTERNATIC, OR PARAGON. 17. ELEIMILSEIMCE A. THIS CONTRACTOR SHALL INSTALL A TELEPHONE SERVICE CONDUIT AS SHOWN ON THE DRAWINGS AND FURNISH AND INSTALL (1) 2' X 2' X 3/4' PLYWOOD PANEL MOUNTED ON THE WALL AT LOCATION SHOWN ON PLANS. IMACEALEMJECEMAY A. SURFACE METAL RACEWAY SHALL BE TWO PIECE 12100 AS MANUFACTURED BY WIREMOLD. ALL NECESSARY ACCESSORIES REQUIRED TO FIT THE CONFIGURATION SHOWN SHALL BE PROVIDED. RECEPTACLES SHALL BE 120 VAC, 23 APUS, CATALOG NUMBER #2127GT. Lighting Summary LTG -SUh1 Zoo. •I_ ss rr.4 rade .atiw IFs=s Lastat Abed poodooeaan) Oroeaaectetasateas was pee41 Pass is at - nee rat* ift4 s)- dowsed ai ea[ctkos *Ann L1G(PA TagtMossd Allowed it Hess Maximum as . use sasiac lersIsk4sebusi+ptamasa,* FaH ws0saws wag WedelvAteleet S*KC Tecb altaetresebanalets lea,eesal Wes unless rssst atS nab pee Ease pr 1 gI *ngwattage(Nntedor) s tig• bins. For e.wepWay.aate.ceasonanetes.e :sw s 2004 Lighting Wattage Maenad a - sassO.e a - WIT= :es Gt.. -..T C a - etassae 10:1€1 FIB END OF DMSION 16 t eseOecsPfoa Maximum Allowed Waetate (Edwin!) ass orere "Wear rinse. Se -st Son State Sioresielertial . - •, Cob Conga= Foss TW Psposei teaas set seemed T.SaiMzederab b irassat ek,eeerel U 11 is 100 IS 0 4 1 1 Tat asset Mc1& Omer. Nis SOS EXPIRED • !REVIEWED FOR = COMPLIANCE annuctl Of Tukwila NG DIVISION 12 2006 Cr11ff _T ; ;v) ft SEP 2 1 ..t11 PERM'. GG -iith . M co W i O. 0 U J 01 i t W _ T E3.O i { El E -' -w ;WE - 0 a , 3 ,,sassj I e i t r . f ;i ACA RGY I V [ i_ iI � 1. DMON 16 - ELECTRICAL SPEI9CA11ONS SECTION nao eECTwcni_ SPECIAL CONDITIONS BEM& A. APPLICABLE PROVISIONS OF NA DOCUMENT A201, "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION", AND DMSION 1 GENERAL CONDITIONS GOVERN WORK UNDER THIS SECTION AND ALL OTHER SECTIONS OF DMSION 16. B. APPLICABLE PROVISIONS OF THIS SECTION GOVERN WORK UNDER ALL OTHER SECTIONS OF DIVISION 16. WORK COVERED BY MIS SECTION SHALL CONSIST OF PROVIDING ALL MATERIAL, LABOR, EQUIPMENT AND SERVICES NECESSARY FOR A COMPLETE, TESTED AND ADJUSTABLE ELECTRICAL INSTAlATLON READY FOR OPERATION AS SPECIFIED HEREIN AND AS SHOWN ON THE DRAWINGS. C. THE TERM CONTRACTOR AS USED IN THIS SECTION SHALL MEAN ANY CONTRACTOR OR SUBCONTRACTOR WHO HAS CONTRACTED TO PERFORM WORK INCLUDED IN AND DEFINED BY 111IS SECTION AND ALL OTHER SECTIONS OF DMSION 16. 2. SIMBACIORIAESPINEKTI A PRIOR TO SUBMITTING HIS BID, CONTRACTOR SHALL CAREFULLY EXAMINE THESE CONSTRUCTION DOCUMENTS, THE DEVELOPER'S EXHIBITS, AND THE SITE, TO INQUIRE FULLY INTO DIFFICULTIES AND COSTS OF WORK, AND TO DETERMINE THE SCOPE AND CHARACTER OF WORK TO BE DONE. CONTRACTOR SHALL INCLUDE ALL NECESSARY COSTS TO LOCATE AND /OR EXTEND ALL UTILITIES INCLUDING UGHTiNG PANELS, POWER PANELS, ELECTRICAL SERVICE. PHONE SERVICE AID /OR MODIFY EQUIPMENT TO MEET THE INTENT OF THE CONTRACT DOCUMENTS. THE OWNER. OWNER'S AGENT, ARCHITECT, ENGINEER OR DESIGNER SHALL NOT BE RESPONSIBLE FOR FAILURE OF THE CONTRACTOR TO DETERMINE DIFFICULTIES AND COSTS IN THE PROJECT OR FOR HiS OVERLOOKING OF THE REQUIREMENTS. B. IF THIS CONTRACTOR DOES NOT CLEARLY UNDERSTAND THE PLANS AND SPECIFICATIONS, OR IF THERE ME ANY REQUIREMENTS WHICH ARE AMBIGUOUS IN THE CONTRACTOR'S OPINION. HE SHOULD CALL THiS TO THE ATTENTION OF THE ARCHITECT PRIOR TO BIDDING, SINCE THIS CONTRACTOR WILL BE HEW RIGIDLY TO THE INTERPRETATIONS OF THE ARCHITECT AND ENGINEER. C. CONTRACTOR SHALL SCHEDULE HIS WORK IN COOPERATION WITH OTHER TRADES INSTALLING INTERRELATED WORK. ALL WORK SHALL BE SCHEDULED TO MAINTAIN SERVICE TO ALL REQUIRED AREAS DURING THE COURSE OF THE CONSTRUCTION EXCEPT FOR SHORT TERM PLANNED SHUTDOWNS. ANY OF WHICH SHALL BE PRE - SCHEDULED WITH THE OWNERS AGENT AND THE LANDLORD. 3. NOBIONISILMOSUARAMIEE A. IN ENTERING INTO A CONTRACT COVERING THIS WORK, THE CONTRACTOR ACCEPTS THE SPECIFICATIONS. AND GUARANTEES THAT THE WORK WILL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. CONTRACTOR FURRIER GUARANTEES THAT THE WORKMANSHIP AND MATERIAL WILL BE OF THE BEST PROCURABLE AND THAT NONE BUT O(PERIENCED WORKMEN DXPERIENCED IN EACH PARTICULAR CLASS OF WORK WILL BE EMPLOYED. CONTRACTOR FURTHER GUARANTEES TO REPLACE AND MAKE G00D AT HIS OWN EXPENSE ANY DEFECTS DUE TO FAULTY WORKMANSHIP OR MATERIAL WHICH MAY DEVELOP WITHIN ONE (1) YEAR AFTER FINN. PAYMENT AND ACCEPTANCE BY THE ARCHITECT. 4. A. CONTRACTOR WILL COMPLY IN ALL RESPECTS WITH THE ADOPTED BUILDING CODES, APPLICABLE LAWS. ORDINANCES. AND REGULATIONS AS MAY APPLY ACCORDING TO THE RULING OF THE CONTROWNG PUBLIC OFFICIAL SHOULD THE CONTRACTOR PERFORM ANY WORK THAT DOES NOT COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE LAWS. ORDINANCES AND REGULATIONS, OR WHICH DOES NOT RECEIVE THE APPROVAL OF THE CONTROLLING PUBLIC OFFICIAL HE SHALL BEAR ALL COSTS ARISING IN CORRECTING THE DEFICIENCIES. ALL ELECTRICAL EQUIPMENT SHALL SHALL BEAR THE UNDERWRiTER''S LABORATORY LIBEL. 5. FEES aN PEAIAf1S A. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND MAKING PAYMENT FOR ALL FEES, PERMITS AND INSPECTIONS RELATING TO HIS WORK. a .IIMBEGLOBAImOS A. THE DRAWINGS SHOW THE GENERAL ARRANGEMENT AND INTENT OF THE DESIGN AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONDITIONS AND THE WORK OF OTHER TRADES WILL PERIiN. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS. IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS. ANO ACCESSORIES WHICH MAY BE REQUIRED. NOR IS IT IMPLIED THAT ALL CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE SYSTEMS OR BUILDING COMPONENTS HAVE BEEN INDICATED. THE CONTRACTOR SHALL INVESTIGATE ALL EXISTING CONDITIONS AFFECTING THE WORK AND ARRANGE HIS WORK ACCORDINGLY, PROVIDING SUCH FITTINGS. OFFSETS, ACCESSORIES AND DEVICES AS MAY BE REQUIRED. THE DRAWINGS AND SPECIFICATIONS ARE RITUALLY COMPLEMENTARY, AND ANY WORK REQUIRED BY ONE BUT NOT BY THE OTHER SHALL BE PERFORMED BY BOTH. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PRUNING ALL MATERIALS AND SERVICES REQUIRED FOR A COMPLETE AND WORKING PROJECT AT NO ADDITIONAL COST EVEN THOUGH EACH AND EVERY NECESSARY ELEMENT THEREOF IS NOT SPECIFICALLY IDENTIFIED HEREIN EACH AND EVERY NECESSARY ELEMENT THEREOF IS NOT SPECIFICALLY IDENTIFIED HEREIN. B. CONTRACTOR SHALL NOT SCALE FROM THE DRAWINGS BUT SHALL FOLLOW THE ARCHITECTURAL DRAWINGS OR DISHING BUILDING CONDITIONS WHERE APPLICABLE, IN ESTABLISHING DIMENSIONS AND LNIES OF RUN, SINCE DIMENSIONS ON THE FINAL ARCHITECTURAL DRAWINGS OR AT THE SHE MAY NOT COINCIDE ODE WiTH THOSE SHOWN ON THE ELECTRICAL DRAWINGS, THE CONTRACTORS SHALL VERRWY WITH THE DIMENSIONED ARCHITECTURAL DRAWINGS OR THE SITE CONDITIONS THE EXACT MATERIAL QUANTITIES AND LENGTHS NECESSARY_ C. SIGNIFICANT DEVIATIONS OR CHANGES FROM THE DRAWINGS WHICH ARE REQUIRED TO ACCOMPLISH THE INTENT OF THE CONTRACT DOCUMENTS MUST BE REVIEWED WITH THE ARCHITECT AND APPROVED BEFORE PROCEEDING. 7. SWUM= AMt A. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS. FOUR (4) COPIES MINIMUM, FOR ALL MANUFACTURED PRODU CTS. EACH SHOP DRAWING SHALL BE REVIEWED BY TIE CONTRACTOR PRIOR TO SUBMITTAL TO ASSURE THAT ALL DIMENSIONS. QUANTITIES,. CONNECTIONS, CAPACITATES AND ACCESSORIES SHOWN ARE N CONFORIUINCE WITH THE CONTRACT DOCUMENTS, AND SHAT BE MARKED OR STAMPED TO CONFIRM THAT SUCH REVIEW WAS MADE AND COMPLANCE WAS COED. B. APPROVAL OF SHOP OR/WINGS BY THE OWNER, OWNER'S AGENT, ARCHITECT, ENGINEER OR DESIGNER. WiLL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBIUTY OF COMPLYING WITH ML TERMS OF THE CONTRACT DOCUMENTS. TIE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR PERFORMANCE OF EQUIPMENT PURCHASED. FOR PROPER FIT. MID OTHER DIMENSIONAL REQUIREMENTS. b BEMBELEIBMEGS A. CONTRACTOR SHALL MARTIAN AT THE JOB SITE ONE SET OF DOCUMENTS AS 'RECORD DRAWINGS' FOR THE PURPOSE OF DAILY MARKING OF ILL SUBSTANTIAL REVISIONS TO THE COMMENTS INCLUDING BUT NOT LISTED TO ELECTRICAL CHANGES. ARID LOCATIONS OF UiRITES, PANELBOARDS. DISCONNECTS, STARTERS AD OTHER DEVICES REQUIRING PERIODIC OPERATIONAL ATTENTION, ADJUSTMENT. OR SERVICE INCLUDING ACCESS THERETO. AT THE COMPLETION OF THE PROJECT, THUS SET SHALL BE RETURNED TO THE ARCHITECT FOR THE PURPOSE OF MAKING NG FNN 'AS -BGCLT OWIWMINGS'. A A. SPECFiC MANUFACTURERS MD MODELS OF EQUPMENT HAVE BEEN USED N THE DEVELOPMENT OF THE ORAiI NGS MD DESIGNS. MI5 CONTRACTOR MUST SUBMIT TO TIE OWNER ANY CHANGES AM /OR SUBSTITUTIONS FOR APPROVAL PRIOR TO IISTALLAIION OR EXECUTION. ANY CHANGES WHICH DO NOT RECEIVE THE OWNERS APPROVAL MAY BE SUBJECT TO REMOVAL OR REPiJYCOIENT AS ORIGINALLY SPECIFIED. MD WILL BE AT THE CONTRACTOR'S EXPENSE. a B. IF THIS CONTRACTOR SUBSTITUTES FOR SPECIFIED EQUIPMENT ANY OTHER EQUIPMENT WHICH REQUIRES MY CHANGES TO THE DESIGN, ALL COST OF REDESIGN AND RECONFIGURATION RESULTING TING FROM SAiD SUBSTITUTION SHALL BE BORNE BY THE SUBMITTING CONTRACTOR. 10. A. CONTRACTOR SHALL SUPPORT PLUMB. RIGID AND TRUE TO -LNE ALL WORK AND EQUIPMENT INSTALLED. THIS CONTRACTOR SHALL DETERMINE HOW EQUIPMENT, FIXTURES. ETC.. ME TO BE SUPPORTED, MOUNTED, OR SUSPENDED MID SHALL PROVIDE ACCESSORIES REQUIRED FOR PROPER SUPPORT WHETHER SHOWN ON THE DRAWINGS OR NOT. IF SUPPORTS ARE REQUIRED. CONTRACTOR SHALL SUBMIT DRAWINGS TO THE ARCHITECT FOR APPROVAL B. PRODUCTS SHALL BE INSTALLED IN ACCORDANCE WiTH MANUFACTURERS PRINTED INSTALLATION AND MAINTENANCE LITERATURE. COMPONENTS REQUIRING PERIODIC MAINTENANCE OR ADJUSTMENTS SHALL BE LOCATED OR INSTALLED AS TO PERMIT ACCESS WITHOUT DAMAGE TO STRUCTURE, FINISHES OR OTHER EQUIPMENT. C. AU. CONDUIT CONNECTING TO SWITCHGEAR, PANELS, MOTORS, AND OTHER EQUIPMENT SHALL BE INSTALLED WITHOUT STRAIN AT THE CONNECTIONS. THE CONTRACTOR MAY BE REQUIRED, AS DIRECTED. TO DISCONNECT CONDUITS TO DEMONSTRATE THAT THEY HAVE BEEN SO CONNECTED 11. A. ALL CUTTING THAT MAY BE NECESSARY FOR THE INSTALLATION OF THE WORK OR ANY REQUIRED PATCHING THAT RESULTS THEREFROM SHALL BE DONE BY THE PROPER TRADE INVOLVED AND SWILL. BE INCLUDED AS PART OF THIS CONTRACT. PATCH TO DUPLICATE UNDISTURBED ADJACENT FINISHES. COLORS, TEXTURES AND PROFILES. COLUMNS. BEAMS, GIRDERS OR JOISTS SHALL NOT BE CUT. 8. ALL. WORK AFFECTING ROOF OR STRUCTURES SHALL BE PERFORMED BY LANDLORD'S CONTRACTOR AT TENANT'S CONTRACTOR EXPENSE. 12. .2E A. COMPLETION AS IT PERTAINS TO THE CONTRACT COMPLETION DATE iS DEFINED AS THE DAY THE PROJECT IS TURNED OVER TO THE OWNER IN THOROUGHLY CLEAN CONDITION. READY FOR THE OWNER TO TAKE POSSESSION. ALL FIXTURES. MOTORS, EQUIPMENT AND ALL OTHER ELECTRICAL EQUIPMENT FURNISHED OR INSTALLED BY THE CONTRACTOR SHALL BE THOROUGHLY CLEANED. 13. MIS A. PROVIDE THE TESTS AS OUTLINED HEREINAFTER AND OTHER TESTS NECESSARY TO ESTABLISH THE ADEQUACY, QUALITY, SAFETY, COMPLETED STATUS MD SUITABLE OPERATION OF EACH SYSTEM. CORRECT PROMPTLY ANY FAILURE OR DEFECTS REVEALED BY THESE TESTS AND RECONDUCT TEST ON THE CORRECTED ITEMS. B. TEST THE GROUNDS WITH A GROUND RESISTANCE DIRECT READING SINGLE -TEST MEGGER. C. INSULATION RESISTANCE BETWEEN PHASE CONDUCTORS MID GROUND NOT LESS THAN 1,000,000 OHMS. D. THE PANELBOARDS SHALL HAVE PHASE CURRENTS BALANCED TO WITHIN +/- 10X VARIATION BETWEEN AVERAGE PHASE CURRENT AND MEASURED INDIVIDUAL PHASE. E. AN OPERATIONAL TEST OF THE EMERGENCY LIGHTS AND THE EXIT LIGHTS SHALL BE PERFORMED FOR THE OWNER TO DDAONSiRATE CONFORMANCE TO THE SPECIFICATIONS. A. TEMPORARY EI EC1RiCAL SERVICE SHALL BE IN ACCORDANCE WITH THE BUILDING CODE TEMPORARY LIGHTING SHALL BE PROVIDED BY A LAMP LOCATED FOR EVERY 625 SQUARE FEET OF BUILDING AREA WITH A MINIMUM OF ONE PER ROOM. THE LAMP TO BE 100 WATT AND SHALL BE MAINTAINED BY THE GENERAL CONiRACiOR. B. TEMPORARY POWER DISTRIBUTION SHALL BE SUFFICIENT TO ACCOMMODATE THE TEMPORARY UGH TING AND CONSTRUCTION OPERATIONS, INCLUDING THE USE OF POWER TOOLS (BUT NOT INCLUDING HEAVY -DUTY ELECTRICAL WELDING UNITS). ELECTRICAL HEATING UNITS, AND START -UP OF SPECIFIED BUILDING EQUIPMENT, WHICH iS TO BE TESTED, STARTED OR PLACED INTO OUR USE PRIOR TO COMPLETION OF RS PERMANENT POWER CONNECTIONS. 15. EXCONIELNIILMBILL A. CONTRACTOR SHALL DO ALL EXCAVATION REQUIRED AS SHOWN ON PLANS OR REQUIRED FOR PROPER OPERATION. EXCESS EXCAVATION BELOW THE REQUIRED LEVEL SHALL BE BACKFIELD WITH EARTH AND THOROUGHLY TAMPED. UTILITY SERVICES, SHALL BE INSPECTED AND APPROVED BY THE PROPER INSPECTION AUTHORITY BEFORE BAcKFUJNG. SWIM 16200 ELECTRICAL POWEFT APD U01111NCi 1. numunaseas A. APPLiCJABLE PROVISIONS OF AA DOCUMENT A201, 'GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION'. DIVISION 1 GENERAL CONDITIONS MD SECTION 16100 ELECTRICAL SPEC2AL CONDITIONS GOVERN WORK UNDER THIS SECTION. B. REFER TO SECTION 16100 ELECTRICAAL SPECIAL. CONDITIONS REGARDING REGULATIONS AND REQUIREMENTS AFFECTING ALL WORK DESCRIBED IN THIS SECTION. 2. ZUMILSUBICE A. POWER SERVICE FOR THRS PROTECT SHALL BE PROVIDED FROM THE EXISTING MALL DISTRIBUTION SYSTEM. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MALL MANAGEMENT TO INSURE THAT ALL WORK AND MATERIALS ARE N CONFORIONCE WITH THE LANDLORD'S REQUIREMENTS. 3. A. ELECTRICAL EQUIPMENT, INCLUDING BUT NOT UNTIED TO. PANO.BIW S, DISCONNECTS CONTROLS, ETC., SHALL BE IDENTIFIED WITH THREE LAMINATED PLASTIC. THE OUTSIDE LAMINATIONS SHALL BE BLACK ENGRAVING SHALL EXTEND THROUGH THE FRONT LAI NATION SO THAT THE BLACK LETTERS APPEAR ON A WHITE BACKGROUND. NAMEPLATES SHALL BE PERMANENTLY ATTACHED WITH SCREAMS. D CIRCUIT DIRECTORY SHALL BE TYPEWRITTEN (HADNRRITTEN IS NOT ACCEPTABLE) AND SHALL D ENi1FY 1f NT AS TO TYPE AND LOCATION AS FOLLOWS: 'LTG' - FOR LIGHTING CIRCUIT FOLLOWED BYl AREA N WHICH MINT APPEARS, LE, 'STOGQROOMP. 'CASH WRAP; ETD "REC1Pr - FOR RECEPTACLE CIRCUIT FOLLOWED BY AREA N WHICH RECEPTACLE APPEARS, "STOREFRONT; 'CASH REGISTER, ETC. 'MOTOR.' - FOR MOTOR FOLLOWED BY THE EQUIPMENT DENTFICATiON AND AREA IN WHICH MOTOR IS LOCATED, I.E. "Dal FAN TOILET', 'AHU- ROOF', ETC. 4. Magi A. ALL SONG SHALL BE RUN N CONDUIT THAI WALL OfT COt'DU T SHALL BE USED SUES 1/2' THROUGH 2 -1 /2 ALL CONDUITS URGER THAN 2 -1/2" SHALL BE NEMMIML CONDUITS INSTALLED UNDERGROUND OR N CONCRETE SCABS SHALL BE RIC JACICETED FLEXIBLE STEEL CONDUIT (SEALTITE) SHALL BE USED N WET AREAS MD ON ML MOTORIZED EQUIPMENT. FUMBLE CONDUIT MAY ONLY BE USED FOR FINAL coreecnoes. AT A YA IN NUMN LENGTH OF 6 FEET. NO BX, ROAM ARMORED CABLE, ETC` SIMLL BE ALLOWED. • & WIRE AND CABLE A. ALL WIRE AND CABLE SHALL BE RUN N CONDUIT. ALL WIRE AND CABLE FEEDERS AND BRANCH CIRCUITS SHALL CONFORM TO THE LATEST REQUIREMENTS OF THE CURRENT EDITION OF THE N.E.C. AND SHALL MEET ALL ASTM SPECiFICATK INS. WIRE AND CABLE SHALL BE NEW, SHALL HAVE SIZE, GRADE OF INSULATION VOLTAGE AND MANUFACTURER'S NAME PERMANENTLY MARKED ON OUTER COVERING AT REGULAR INTERVAL AND SHALL BE DELIVERED IN COMPLETE COILS OR REELS WITH IDENTIFYING SiZE AND INSULATION TAGS. 6. =nun= A. A COLOR CODING SYSTEM AS LISTED BELOW SHALL BE FOLLOWED THROUGHOUT FOR FEEDERS MD BRANCH CRCUITS AND USED AS A BASIS FOR BALANCING LOAD. 9. B. ALL OPENINGS IN FIRE AND SMOKE WALLS, PARTITIONS, FLOORS AND OTHER SIMILAR PENETRATIONS FOR ELECTRICAL CONDUITS, CABLE OR EQUIPMENT, WHETHER CUT OR IN PLACE, SHALL BE CLOSED WiTH A UL APPROVED FIRE RESISTANT SILICONE FOAM SEALANT TO MAINTAIN THE FULL RATING AND INTEGRITY OF THE PARTITIONS, WALLS OR FLOOR. C. CONDUIT BENDS FOR POWER AND LIGHTING CIRCUITS SHALL NOT BE LESS THAN STANDARD RADIUS BENDS. CONDUIT BENDS FOR FEEDERS. TELEPHONE AND COMMUNICATION CIRCUITS SHALL NOT BE LESS THAN LONG RADIUS BENDS. D. 02. TYPE DX, TX, OR AX CONDUIT EXPANSION DEFLECTION FITTINGS ARE REQUIRED IN ALL CONDUIT RUNS WHERE MOVEMENT MAY BE ENCOUNTERED. ALL EMT COUPLINGS SHALL BE COMPRESSION TYPE. E. EXPOSED CONDUIT SHALL BE SECURELY SUPPORTED IN PLACE PER CODE BUT ON A MAXIMUM OF 10 FOOT INTERVALS, WUHN THREE FEET OF EACH BEND, AT EVERY OWLET OR JUNCTION BOX AND AT THE END OF EACH STRAIGHT RUN TERMNATNG AT A BOX OR CABINET. CONDUIT SHALL NOT BE SUPPORTED FROM DUCTWORK OR PIPE WORK. CONDUITS SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO THE BUILDING LINES. GENERALLY, CONDUIT SHALL BE RUN IN CONTACT WITH STRUCTURAL PARTS OF THE BUILDING SO AS TO AVOID SUSPENDED LENGTHS OF CONDUIT. CONDUIT SHALL BE INSTALLED AS TO BE ACCESSIBLE FOR REPLACEMENT AND MAINTENANCE AND GENERALLY CONDUIT SHALL BE INSTALLED TO PERMIT DRAINAGE. 8. THE ELECTRICAL CONTRACTOR SHALL CALCULATE VOLTAGE DROP ON CONDUCTORS WITH LENGTHS GREATER THAN 75 FEET FROM THE PANELBOARD AND PROPERLY SIZE THE CONDUCTORS PER N.E.C. C. POWER CONDUCTORS: NO WIRE LESS THAN NO. 12 SHALL BE USED EXCEPT FOR CONTROL CIRCUITS OR LOW VOLTAGE WIRING. WIRE SIZES NO. 12 TO NO. 10 SHALL BE SOLID EXCEPT WHERE OTHERWISE INDICATED. WIRE SUES NO. 8 AND LARGER SHALL BE STRANDED. ALL WIRE SIZES SHOWN ARE AMERICAN WIRE GAUGE SIZES. SIZES NO. 12 AWG THROUGH NO. S AWG SHALL BE 'THEW." SIZE 4 AWG AND LARGER SHALL BE 'T HW.' D. CONTINUITY: ALL WIRES SHALL BE CONTINUOUS FROM OUTLET TO OUTLET. E. ACCEPTABLE MANUFACTURERS: CABLE AND WIRE SHAT BE STANDARD TYPE AS MANUFACTURED BY GENERAL CABLE COMPANY, CAROL, ANACONDA, ROM OR ITT ROYAL --- 120 /206V: PHASE A-- BLACK, PHASE B- -RED. PHASE C- -BLUE, NEUTRAL -- WHITE. GROUND--GREEN -- 277 /480V: PHASE A-- BROWN. PHASE B-- ORANGE, PHASE C-- YELLOW, NEUTRAL- -GRAY, GROUND- -GREEN 7. A. ALL OUTLETS SHALL BE PROVIDED WITH GALVANIZED OR SHERARDiZLD BOXES SUITABLE IN DESIGN TO THE SPACE THEY OCCUPY AND THE PURPOSE THEY SERVE. WALL MOUNTED OUTLET BOXES, EXCEPT FOR 2' PARTITIONS SHALL BE AT LEAST 1 1/2' DEEP AND/OR DEEPER IF REQUIRED BY THE DEVICE THEY HOLD OR THE NATIONAL ELECTRICAL CODE. B. ALL PULLBOXES SHALL BE MADE OF GALVANIZED STEEL, OF METAL GAUGE AND PHYSICAL SUE AS REQUIRED BY THE NEC FOR THE NUMBER AND SIZE OF RACEWAYS AND CONDUCTORS INVOLVED. C. FIXTURE OUTLET BOXES IN OR ON CEILINGS SHALL NOT BE LESS MAN 1 -1/2' DEEP OR LESS THAN 4' SQUARE. ALL OUTLET BOXES INTENDED TO SUPPORT FIXTURES SHALL BE EQUIPPED WITH 3/8' FIXTURE STUDS FASTENED THROUGH THE 80170M OF THE BOX WITH FOUR BOLTS. 8. LICIILINIFIEEILPAELOMS A. PANELS SHALL BE DEAD FRONT, SAFETY TYPE, FURNISHED WITH BRANCH CIRCUIT PROTECTING DEVICES, EQUIPMENT GROUNDING BOX, MAIN BUS AND CABLE LUGS FACTORY ASSEMBLED. WITH ALL COMPONENTS IN PLACE, READY FOR INSTALLATION. PROVIDE 20% SPARE BREAKER CAPACITY AND 25% EXCESS AMPACiTY IN EACH PANEL B. CURRENT CARRYING CONTACT SURFACES SHALL BE SILVER OR TIN PLATED. THE CIRCUIT BREAKERS SHALL BE OF THE MOLDED CASE, BOLT -ON TYPE SUITABLE FOR VOLTAGE AND AMPERE RATINGS INDICATED ON DRAWINGS AND IN SCHEDULES AND SHALL HAVE A MINIMUM INTERRUPTING CAPACITY OF 10.000 AMPERES FOR 120 /206V AND 14.000 AMPERES AT 277/48011. C. MAIN BUSES AND CONNECTORS SHALL BE HARD DRAWN COPPER OF 98% CONDUCTMiY, WITH CURRENT CARRYING CAPACITY TO MAINTAIN ESTABLISHED RISE TESTS AS DEFINED IN UL STANDARD UL 67. D. CABINET SAES ARE BASED UPON A 20' WIDE BY 6' DEEP PANEL UNLESS OTHERWISE NOTED. PMNELBOARDS SHALL BE EQUIPPED WITH FLUSH TYPE LOCK AND CATCH. ALL LOCKS SHALL BE KEYED ALIKE, AND TWO KEYS ARE TO BE SUPPLIED WITH EACH LOCK. E. PANELBOARDS TO BE BY SQUARE D CORPORATION, GENERAL ELECTRIC, OR SIEMENS. BffigiagaBS A. DRY -TYPE TRANSFORMERS SHALL BE OF THE ENCLOSED VENTILATED TYPE WITH KVA MD VOLTAGE RATING AS CALLED FOR ON THE DRAWINGS AND WITH 150' CLASS H INSULATION AND MINIMUM OF SIX STANDARD FULL CAPACITY TAPS. SOUND LEVEL SHALL BE LOW AND INSTALLATION SHALL INCLUDE KORFUND OR EQUAL VIBRATION DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY. (MOUNT TRANSFORMER ON VIBRATION ISOLATORS). LOCATE TRANSFORMER AS NOT TO CAUSE SERVICING OR CLEARANCE DIFFICULTIES OF VIOLATIONS WITH OTHER EQUIPMENT. • COMPARABLE EQUIPMENT AS MANUFACTURED BY SQUARE CORPORATION OR GENERAL ELECTRIC 10. infitaLSMOIS A. TOGGLE SWITCHES SHALL BE WHITE AND SHALL BE RATED 20 AMPERES 120 /277 VOLT AC TYPE AS MANUFACTURED BY HUBBELL AND SHALL BE AS FOLLOWS: SINGLE POLE -- 1221 - -1 THREE WAY -- 1223 - -1 B. TOGGLE SWITCHES SHALL BE MOUNTED 4'-0' ABOVE FINISHED FLOOR TO MOUNTING PLATE AND, AT DOORS, mu m° ADJACENT TO THE TRIM ON THE STRIKING SIDE OF THE DOOR, REGARDLESS OF THE LOCATION NDICATED ON THE DRAWINGS; THEREFORE, CHECK ALL DOOR SWINGS BEFORE INSTALLATION OF CONDUIT OUTLETS. C. COMPARABLE EQUIPMENT AS MAMUFACRURED BY RATER, LEVITON, AND BRYANT WILL BE ACCEPTABLE 11. A. RECEPTACLES SHALL BE WHITE AS MMFJFACTURED BY HUBBEL AND SHALL BE AS FOLLOWS: DUPLEX RECEPTACLE --20A-120 VOLT 5362 -1 EL RECEPTACLES SHALL BE MOUNTED 12' ABOVE THE FNStED FLOOR UNLESS OTHERWISE NOTED. C. COIRAiABLE EQUIPMENT AS MAMIFACRIRED BY SERRA ELECTRIC CORPORAiIONN, SLATER BRYANT AHD LEMTON WILL BE ACCEPTABLE. • 12. DEMSLELMES A. DEVICE PLATES SHALL BE WHITE UNLESS OTHERWISE NOTED. COMPARABLE EQUIPMENT AS MANUFACTURED BY SIERRA ELECTRIC CORPORATION, HARVEY HUDDLE INC., BRYAiNT AND LEVITON WiI.L BE ACCEPTABLE. PANT MATCH ADJACENT FINISH COLOR. 13. DISMERIECUMGES A. FURNISH AND INSTALL DISCONNECT SWITCHES AS REQUIRED BY CODE. DISCONNECT SWITCHES SHALL BE NEMA HEAVY DUTY TYPE AND UNDERWRITERS LABORATORIES LISTED. MANUFACTURED BY SQUARE D CORPORATION, ITE, GENERAL ELECTRIC, OR WESTINGHOUSE. 14. MAIM A. CONTRACTOR SHALL INSTALL A SYSTEM GROUNDING SYSTEM AND AN EQUIPMENT GROUNDING SYSTEM AND SHALL USE ONLY APPROVED GROUNDING CLAMPS AND CONNECTORS AS MANUFACTURED BY PENN -UNION, BURNDY, OR 0-Z MFG. COMPANY. B. THE SYSTEM GROUNDING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND THE UTILITY COMPANY REGULATIONS. CONTRACTOR SHALL CONNECT THE GROUNDING ELECTRODE CONDUCTORS TO THE NEUTRAL BAR INSIDE THE MAIN PANEL WHEN TRANSFORMERS ARE USED TO PROVIDE A SEPARATELY DERIVED SYSTEM, THE CONTRACTOR SHALL CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE NEUTRAL BAR INSIDE THE SECONDARY SYSTEM PANEL OR SERVICE RATED DISCONNECT SWITCH, DO NOT CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE NEUTRAL LUG INSIDE THE TRANSFORMER. 18. C. THE EQUIPMENT GROUNDING SYSTEM SHALL CONSIST OF A CONTINUOUS CONDUIT INSTALLATION AND A GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR. THIS GROUNDING CONDUCTOR SHA 1. BE INSTALLED IN EVERY CONDUIT OR RACEWAY WITH THE FEEDER OR BRANCH CIRCUIT CONDUCTORS. THIS GROUNDING SHALL BE EXTENDED FROM THE HOUSING OF EVERY ELECTRICAL LOAD, THROUGH PANELBOARD STATIC GROUNDING BUSSES, TO THE STATIC GROUNDING BUS N THE MAIN PANEL. THE GROUNDING BUS SHALL BE BONDED TO THE GROUNDING NEUTRAL BAR INSIDE THE MAIN PANEL 15. LIMMIGIDMIMB A. ALL LIGHTING FIXTURES AND LAMPS SHALL BE FURNISHED BY OWNER, UNLESS NOTED OTHERWISE. THIS CONTRACTOR Stall INSTALL LIGHTING FIXTURES AND LAMPS AS INDICATED ON THE DRAWINGS AND AS SPECIFIED BELOW, COMPLETE WITH HANGERS. PLASTER FRAMES AND ALL OTHER NECESSARY ACCESSORIES. B. ALL BALLAST. STARTERS AND LAMPHOLDERS IN FLUORESCENT LIGHTING EQUIPMENT ARE TO BE ELECTRICAL TESTING LABORATORIES, UNDERWRITERS LABORATORIES AND CERTIFIED BALLAST MANUFACTURERS APPROVED. ALL BALLAST FOR FLUORESCENT RXRIRES SHALL BE OF THE HIGH POWER FACTOR TYPE AND SHALL BE GENERAL ELECTRIC 'MAXI -MISER II' OR ADVANCED MARK III. WHERE OCTRON LAMPS ME SPECIFIED PROVIDE APPROPRIATE BALLASTS. C. THIS CONTRACTOR SHALL VERIFY THE FINAL CEILING AND FiNISH SCHEDULES TO INSURE THE PROPER INSTALLATION AND MOUNTING OF FIXTURES AND SHALL COORDINATE BEFORE MAKING SUBMITTALS. 16. A. TIMECLOCKS SHALL BE 24 HOUR. 7 DAY , DAY SKIPPER TYPE AS MANUFACTURED BY TORK, INTERNATIC, OR PARAGON. 17. ELEIMILSEIMCE A. THIS CONTRACTOR SHALL INSTALL A TELEPHONE SERVICE CONDUIT AS SHOWN ON THE DRAWINGS AND FURNISH AND INSTALL (1) 2' X 2' X 3/4' PLYWOOD PANEL MOUNTED ON THE WALL AT LOCATION SHOWN ON PLANS. IMACEALEMJECEMAY A. SURFACE METAL RACEWAY SHALL BE TWO PIECE 12100 AS MANUFACTURED BY WIREMOLD. ALL NECESSARY ACCESSORIES REQUIRED TO FIT THE CONFIGURATION SHOWN SHALL BE PROVIDED. RECEPTACLES SHALL BE 120 VAC, 23 APUS, CATALOG NUMBER #2127GT. Lighting Summary LTG -SUh1 Zoo. •I_ ss rr.4 rade .atiw IFs=s Lastat Abed poodooeaan) Oroeaaectetasateas was pee41 Pass is at - nee rat* ift4 s)- dowsed ai ea[ctkos *Ann L1G(PA TagtMossd Allowed it Hess Maximum as . use sasiac lersIsk4sebusi+ptamasa,* FaH ws0saws wag WedelvAteleet S*KC Tecb altaetresebanalets lea,eesal Wes unless rssst atS nab pee Ease pr 1 gI *ngwattage(Nntedor) s tig• bins. For e.wepWay.aate.ceasonanetes.e :sw s 2004 Lighting Wattage Maenad a - sassO.e a - WIT= :es Gt.. -..T C a - etassae 10:1€1 FIB END OF DMSION 16 t eseOecsPfoa Maximum Allowed Waetate (Edwin!) ass orere "Wear rinse. Se -st Son State Sioresielertial . - •, Cob Conga= Foss TW Psposei teaas set seemed T.SaiMzederab b irassat ek,eeerel U 11 is 100 IS 0 4 1 1 Tat asset Mc1& Omer. Nis SOS EXPIRED • !REVIEWED FOR = COMPLIANCE annuctl Of Tukwila NG DIVISION 12 2006 Cr11ff _T ; ;v) ft SEP 2 1 ..t11 PERM'. GG -iith . M co W i O. 0 U J 01 i t W _ T E3.O i {