Loading...
HomeMy WebLinkAboutPermit M06-204 - BOEING #9-101BOEING #9 -101 9725 EAST MARGINAL WY S M06 -204 Parcel No.: Address: Suite No: City ori Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us 0003400018 9725 EAST MARGINAL WY S TUKW MECHANICAL PERMIT Tenant: Name: BOEING #9 -101 Address: 9725 EAST MARGINAL WY S, TUKW ILA WA Owner: Name: THE BOEING COMPANY Address: PO BOX 3703 M/S #1 F-09, SEATTLE WA Contact Person: Name: DANI MEYERS Address: 1221 2 AV N, KENT WA Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N, KENT, WA Contractor License No: HERMACLOO5BJ DESCRIPTION OF WORK: INSTALL (1) NEW ROOFTOP AIR HANDLING UNIT AND ASSOCIATED DUCT WORK TO PAINT HOOD. Value of Mechanical: $60,000.00 Type of Fire Protection: SPRINKLERS Furnace' <100K BTU >100K BTU Floor Furnace Suspended/Wall /Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial /Industrial doc: IMC- Permit EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 1 0 0 0 0 1 0 0 **continued on next page ** M06 -204 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 575 -9700 Phone: 206 - 575 -9700 Expiration Date: 08/25/2008 Steven M. Mullet, Mayor Steve Lancaster, Director M06 -204 10/04/2006 04/02/2007 Fees Collected: $638.50 International Mechanical Code Edition: 2003 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU 30 -50 HP/1,750,000 BTU 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 10 -04 -2006 Permit Center Authorized Signature: I hereby certify that I have read and ordinances governing this work will b Print Name: doc: IMC- Permit City b? Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: cttukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: MO6 -204 Issue Date: 10/04/2006 Permit Expires On: 04/02/2007 Date: 10 1(1 k is permit and know the same to be true and correct. All provisions of law and with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. / Signature: Date: (p/ `f / D(p A ny This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M06 -204 Printed: 10 -04 -2006 City &Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: cttukwila.wa.us Parcel No.: 0003400018 Address* 9725 EAST MARGINAL WY S TUKW Suite No: Tenant: BOEING #9 -101 1: ** *BUILDING DEPARTMENT CONDITIONS*** PERMIT CONDITIONS Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -204 Status: ISSUED Applied Date: 09/25/2006 Issue Date: 10/04/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***FIRE DEPARTMENT CONDITIONS*** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concems: 11: The total number of fire extinguishers required for an extra hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (4A 40 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 12: A notice of construction permit must be obtained from the Puget Sound Clean Air Agency prior to the installation of the spray booth. The permit shall be posted at the jobsite. 13: Spray booths and spray rooms shall be protected by an approved fire extinguishing system complying with Chapter 9 of the International Fire Code which shall also protect exhaust plenums, exhaust ducts and both sides of dry filters when such filters are used. (IFC 1504.6)(Extend sprinkler protection.) 14: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to doc: Conditions M06 -204 Printed: 10-04-2006 doc: Conditions City or Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ct.tukwila.wa.us * *continued on next page ** Steven M. Mullet, Mayor Steve Lancaster, Director the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 15: Mechanical centilation of spraying areas shall be in accordance with section 510 of the International Mechanical Code. 16: Spraying equipment shall be interlocked with the ventilation such that spraying operations cannot be conducted unless the ventilation system is in operation. 17: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 18: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 19: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 20: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23 These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. M06 -204 Printed: 10-04 -2006 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us ktisi Steven M. Mullet, Mayor Steve Lancaster, Director I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances goveming this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Print Name: L /�A a , S Signature: Date: doc: Conditions M06 -204 Printed: 10- 04-2006 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hrtp: / /www.ci.tukleila.wa. Site Address: g 7.2 5 E. A4( l( Tenant Name: L4 4 Il _ � () i - 4 Property Owners Name: � I r • . Mailing Address: •I so. ata Name: Mailing Address._ �... V(. E -Mail Address: Company Name: Mailing Address: Contact Person: n i ( e../ S E - Mail Address: crn ej PX5 @Nerrr visoh' COf'Y N .- Contractor Registration Number: F t R MA C 1-00 0 Company Name: doe sari ' 1 Mailing Address: Pt> X aJ I C57 Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print ** SITE LOCATION King Co Assessor's Tax No.: 10 1.(.^ • W W_ Rh c, Suite Number: Floor: New Tenant: ❑ Yes ..No city Expiration Date: State CONTACT PERSON — who do we contact when your permit is ready to be issued Day Telephone: -2U0 5 70 - a 7 2 .11 .'. CP1 • .. • L / .• 1 • • • city S Zip Fax Number: zx ` ` 75 GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) - 1. City state q Z ip CO Day Telephone: � 575 q ] � Fax Number: r 7�6& 675 9 <Cc° FSiaSJo 7 ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record die. l_sSA Q %1a4 City State Zip 1 (n� Contact Person: Day Telephone: o�ClO - # -`-t - 1 E -Mail Address: Fax Number: ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: QMwlicatasmsrums- Applicariau On Liite3 -2006 - Permit Applicaiim Aoc Revised 9 -2006 M State Zip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM f Fire Damper 0-3 HP /100,000 BTU Fumace>IOOK BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Pan Connected to Single Duct Themtostat 15 -30 HP /1,000,000 BTU Suspended/WaWFloor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct I Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator – Comm/Ind 1 . MECHANICAL PERMIT INFORMATION - 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: '� -k'!(r iY2r\Sffl l tiv\ pn(1( Mailing Address: ) 1 (-9,--221 5, kh In'V 01R'O3 �_ �� City State zi Contact Person. —/ , I a , J E� , rs Day Telephone: 2O(o 5 7E5 -Q7 E -Mail Address: a meyers ) hPfOS2OLIFYIri HTh Fax Number. Y . — `J Expiration Date: 07 Contractor Registration Number: 1--1 E 12M .Q CL(XOF, P)J Valuation of Mechanical work (contractor's bid price): $ $ c$b Scope of Work (please provide detailed information): \' ■5 t. 1 , re.3.33 Use: Residential: New .... ❑ Replacement.... Commercial: New .... Replacement Tyne: Electric ❑ Gas....®, Other: Indicate type of mechanical work being installed and the quantity below: Q: npp4ratiwwmm- Applications On Iim13-2006 - Permit Applicatipndpc Revised 9-2U06 M V • r al Y hart& ► ng Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entred by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumhinv Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Print Name: J aff I He 1,S Mailing Address: t ac9 l alh A ve. rot ER OR AUTHORIZED AGENT: I Date Application Accepted: t q alt I Qt ApplicaimMama- Applications On Lint 3 -2®06 - Pamit Application&¢ Revise: 9.2006 nn Yr n Date: WA °I ell 53 l State Day Telephone: ao O -515 - Staff Initials: Zip Page 6 af 6 1 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0003400018 Permit Number: M06.204 Address: 9725 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 09/25/2006 Applicant: BOEING #9 -101 Issue Date: Receipt No.: R06 -01565 Payment Amount: 638.50 Initials: JEM Payment Date: 10/04/2006 01:56 PM User ID: 1165 Balance: $0.00 Payee: HERMANSON CO. LLP TRANSACTION LIST: Type Method Description Amount RECEIPT Payment Check 1657 638.50 ACCOUNT ITEM LIST: Description Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES Account Code 000/322.100 516.80 000/345.830 121.70 Total: 638.50 0402 10/05 9710 TOTAL 638.50 doc: Receipt Printed: 1044 -2006 Project: „i 7- /O/ Type N. e of Inspection: �9J7 , * 4' /�4 Addr s: ! �� / Ve Date ailed: Special Instructions: ^� /� ,(� qzx 4 " GG�� 0.06962 79/ Date Wanted: a•� ' 721797 P.m. Request //� -, rte/ Phon o: 1 Approved per applicable codes. D Corrections required prior to approval. COMMENTS: a /7 l - h/ Inspector al .r Date I 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ri $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: (206)431 -3 Projec ' t , y - /(9/ Type of Inspection: �J(D /4,4 ,c »/ Address ; , 2;s E? f I y�Il (� Da a Called: Special Instructions: Q Date Wanted: ltn 9 Requester: Phone No: _� 7� INSPECTION RECORD Retain a copy with permit INSPECTION N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. Corrections required prior to approval. COMMENTS: gdlk k-) r Ai /r, i 4 41— , 4i/ fl - '% - h 1 t 4/9/1/2 ct c Inspector: Date l . - 2 7 ri $58.00 REINSPECTION EE RECUIRED. Prior to inspection, fee must be paid at 6300 Southcent r Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: f Date: ilia._ .. i _ --' fd t?a lasca•S.MP.s m , toy.. ._tsa r.. Project: ., 4ai/N4 /o/ Type of /loci — h w \• Address: - •' 5 225 /45 T;92926oucJ/ ,•[ Date Called: Special Instructions: /uate Wanted: /o? - 9— o G a.m. Requester: Phone No: 020 CI 4 /7 —G20f; Retain a copy with permit ,., l.i 1 INSPECTION RECORD mo- of INSPECTIQN NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 0 Approved per applicable codes. COMMENTS: PA 0 Ej Corrections required prior to approval. 0 - 7 4 ° r?-7 Salle - $581AelREINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: +,q. N 'r l seca'x!! •.1' r r• ,rr., 3r Project: /hoc' Sprinklers: F_; Fire Alarm: Type of Inspection: F..�. ,.., t Address: Suite #: , ; , / ,, - .. f w , , Contact Pers " r .41"x A& Special Instructions: Phone No.: U U 6 � 1 -_ ry L �7 ". Needs Shift Inspection: Sprinklers: F_; Fire Alarm: Hood & Duct: Monitor: p=ly f Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa: 98188 206 -575 -4407 f I 13 1 Approved per applicable codes. n Corrections required prior to approval. COMMENTS: mil • Inspector: 5'( 5) 5 Date: 2))21o7 Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection., Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 ACTIVITY NUMBER: M06 -204 DATE: 09 -25 -06 PROJECT NAME: BOEING #9 -101 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 4•0 a Bui ing Divi ision Public Works Complete Comments: Documents/routing slip.doc 2 -28-02 ,,,,,PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Ji✓ (0 -2. Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DATE: Planning Division ❑ Permit Coordinator ❑ DUE DATE: 09-26-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTJNG: Please Route u Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DUE DATE: 10-24-06 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License HERMACL005BJ Licensee Name HERMANSON COMPANY LLP Licensee Type CONSTRUCTION CONTRACTOR UBI 602004844 Ind. Ins. Account Id PARTNER/MEMBER Business Type LIMITED LIABILITY COMPANY Address 1 1221 2ND AVE N Address 2 City KENT County KING State WA Zip 980322945 Phone 2065759700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/11/2000 Expiration Date 8/25/2008 Suspend Date Separation Date Parent Company Previous License HERMAC'217NT Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HERMANSON, RICHARD L PARTNER/MEMBER 01/01/1980 ALMON, KEVIN PARTNER/MEMBER 01/01/1980 MACDONALD, JAMES PARTNER/MEMBER 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 ir' `v Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Expiration Date Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= HERMACL005BJ 10/04/2006 DRAWING INDEX DRAWING NUMBER 9- 101 -A1 9- 101 -RFS4 _ - - - _ 9- 101 RfS503 --- - - - - -- - ----- -- - _ - - ------ - - - - -- - - - -_ -- - ' .. _.. - ..._ - - ....... -' - -' - - - -. . - -.- - .-- - - - - -- -- - - ' - - - -- - - - -. _..- ---- -..... - - - _ _---- _-__ _ ______.______ _____ SHEET Al RFS4 _ RFS503 - - - .._.. . _ . _ - -- - ---- - -- - - - -- - . -- - __ ____ - --- - - - -. REV A E '08.09.06 D - -' . _ - DAZE 08.09.06 18.09.06 TITLE TITLE SHEET ' ARTIAL PLAN . ECTIONS & DETAILS • Non ' - - - P4t1 irsvlew approval Is sobiott to atom acid orabdoni of oort on doa n does trot atAltorfr fhb tllotation of arry aocaed node or pglrwtroer, «approved Reid copy and had owbd I V 0 ,_-. tabs , / MD= DIVISION • i .. , • ' _ - - . - ( e • . . • I 1 It iaRAT PERMIT QuIRED ! ;Mechanical ■ P[Ytrl'Ibing O QsPiping City of Tukwila WIN DIVISION • _ . . .. 1 ___ ______ _ ______ - -- - ----- - -'- -- - Stu ear Oat Rbes04 Br Awe i A IR g 51 FE w i l iV” • ACCEPTABitilY MS CtSX�i Awjc SPEfiFU1Tm 6 A a_ MOOR TE ' -A; -o_ TITLE SHEET 56628201 MU 01.01.06 - 1;e r � ' A PANT 600TH lJ Er SrE via BUILDING 9-1 Q1 D G APPROwED Err Can_ DATE J �- 566282-01 I 566282 -01 t I r I _ _ _ ; 9-101 -A i _ ARCHITECTURAL MISTER VICINITY MAP • 99 FROM SEATTLE - TACOMA AIRPORT FROM DOWNTOWN SEATTLE 1 5 - r \ \ \\ \\ \ \ \ ; \ `\ \:\ \ ggA , � t . _ s. Z 1 \ �' ' O c \ ■ ` , \ � I* •; ; to \ I. \;I y ) - - - ,______ f EAST VARIAN. SW CORPORATE PARK DEVELOPM CENTER • PROJECT SITE 900 NO SCALE 5 (x1 157 . \ \ FROM KENT \ % 900 & AUBURN t BOEING DEFENSE & SPACE GROUP BUILDING 9 -101 REPLACE PAINT BOOTH AHU J #566282 -01 BUILDING ADDRESS: 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 9- 7 9^ 78 35 9 -52 0 AREA MAP BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 9 -101 BUILDING LOCATION PROJECT SITE NO SCALE CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITII CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO JOHN MURDOCH AT BUILDING 9 -51.2 COLUMN C /3, AFTER COMPLETION OF THIS CONSTRUCTION. CHECK BOX • THESE DRAWINGS AND THE WAC 51 AND COMPLIANCE GENERAL NOTES PROJECT CHECKLIST _ CONFORM TO THE 2003 LB, I.F.C., I.P.C., I.M.C., U.P.C. -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES WITH CITY OF TUKWILA ZONING. • ROOMS LABELED PER OCCUPANCY PER I.B.C. O BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. O NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: O 1. GENERAL PERMIT (SHELL & CORE) p 4 SETS OF STRUCTUAL REPLACEMENT C] 2. TENANT IMPROVEMENT (NON- STRUCTURAL): • 3. TENANT IMPROVEMENT (REVISION), 2 SETS. C] 4. MECHANICAL, 4 COMPLETE SETS_ D 5. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS. II BRIEF PROJECT NARRATIVE: REPLACE EXISTING AHU FOR PAINT BOOTH. PROVIDE NEW ROOF MOUNTED UNIT. REMOVE EXISTING MONORAIL AND CHAIN HOIST AND ASSOCIATED STRUCTURE IN PAINT BOOTH AREA REMOVE EIOSING DOOR AND PROVIDE DUCT PENETRATION THROUGH EXTERIOR WALL a • DRAWINGS 1 LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS TUNNEL FIRST FLOOR MEZZANINE AFFECTED AREA BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE N o c h a nges shall be made to the scope c ; t without prior approval of .l:1 etaldIng DINIs_3n. N OTE: ftv : :.; vd : :I require a new plan submittal e m:y Inc,ida additional plan review tees. CODE SUMMARY TUKWILA 2003 I.B.C., I.F.C., I.P.C., I.M.C., U.P.C. AND THE WAC 51 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. GROUP B AND GROUP F, DIVISION 1 (OFFICE AND FACTORY) TYPE II, NON- COMBUSTIBLE SEPARATION 60 FEET (MINIMUM ALL SIDES) 713,829 1,116,306 50,910 713,829 55,689 295,878 1800 SF OF SHOP AREA & 200 SF ROOF AREA 1I1 FT. MAXIMUM 2 OVERALL (P40 CHANGES) BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT 3 • s C1TVnFT1 SFp 2 5/1106 PEVA ITCEMER AX0-9_01 i ° - " G1 -Ala , r 1 • TCF AEROVENT X14 BIA FAN RATED TO 1000 CFM-41--/WC— ESP WITH 3/4" HP, 460 V MOTOR & 500' F CONSTRUCTION TORIT MOD. VS -2400 S/N 10355532 460V / 3 PH 5 HP 2400 CFM 5.7 ESP CCOMMATION WADER UP STRUCTURAL PLATFORM SEE DWG 109 - 101 - 1656 -S1 1M10 4551 -M3 10 "0 STACK TO 25' CMG A iM10LM557 10' DIM. EXHAUST DUC 8 " HAMA WEATHER CAP PER DNS. KSC- STD -M ExST V.U. AFI1{ REV rAt 8 "O IZEVISON FAN /UUU CFM (A) ---- TORT 90 CAB S/N 1G077334 -3 3 HP 208/460 / 3 PHASE B 32- 008012 1425 CFM 5 [�j =i G n III' . owe EXHAUST FANS 7000 CFM EACH le-" ink 11410 4551 - 4 1 1. Da{ STACK 1. if TO 25' AFG _l1 1 1410 109 -101 -4553 5E6282 -OO er D 110> AIR FILTER 6,500 CFM OUTSIDE AIR 4551 -M3 M557 8"• DUCT Yr/ 11TS:AA ROUEN T SZE 22 BIA FAN SET RATED TO 3000 CFM O /2' ESP W : ' 3/4' HP, 460 V MOM OR AND HIGH TEMP 500' I: ` CONSTRUCI'.ON DE R'AS KVIF 08.08.06 sew ( AIIU 105 PAU. I / 2 A -18 6,500 CFM 0 3" SP, 7.5 HP STAIR "A" ism Nol Fi X50 CFM AHU j2 20,000 CFM 1M10 4551 -M4 B.O. DUCT EL - 18' -2' FLEX / CONN DISCONNECTED DUCTWORK 1M10 4551 -M4 pm sir 11410 4551 -M4 ric>EXH. FAN 6,500 CFM 24/22 I2D 1 124/1 dg 1124/8( 24/10 flrsrr T. I1 J .■ :1 I■ ,lsi,r[' ■ IF Ilrl Vi. AIR PUMP SCOTT 1605041 (3' -0" AFF) 1M10 45 INSPECTION DOOR ADJ. LOUVER PARCEL STORAGE AREA SEE 1M10 11.4501 1/2" CPLG AFF) r AH1D0 A PACE -20 FLEX CONN. FOR OVEN DUCTWORK SEE 11410 M595 L G INSTAL SP1NOLE SAIWER Z • 11 LGE- AUBURN 1)8 ON -LOADS ROAN F RE- WALL CO A.. OSC/BaT S&S(R J VD4TuTION 1AX6 FOR ETAT T K WEIL E leiTIATArN REVSON 32/24 UP TO ROOF 711791 -00 120129 -00 130198 -00 54742600 54742606 BY DWfRAS GIV HA RR WRR SECURITY : ARS SEE 130E1 STD 83 -B AC 0 m r 660 *MAD o�rc MM 04/02/01 RNS 03/06/02 R*S 09.30.03 MUM 04/06/05 RAS 09/09/05 (10) 36 "x18' GRILLES 0 2,000 CFM EA. 55/24 64/24 nt ra E /iY 0' 1 BAND SAW 600 CFM GRINDER 450 CFM 13.0. DUCT 5 110 EL - 1 ACCEPTABILITY n s r€ GN Ae /CR SPECEXATICN 6 *PRIMO IWPRoval F3': OEM DATE Dam CHU < HARM citcKED CHECKED APPOOYED NSW 1 M3 CURING ROOM 1M10 4551 -M2 PLATE EL. 17' -0" STRUCTURAL PLATFORMS SEE DWG 109 -101- 1656 -S1 0/A 62/46 SECURITY BARS SEE OYrG. 83- BMAC -1 TO AC -1 (REPLACED AHU 14) PLAN SCALE: 1/8.. = amnia T rx 0 MECHArNECAL MASTER i HVAC DUCTWORK - PARTIAL PLAN BUILDING 9 -101.7 COL A -E/1 -6 DESCRIPTION PACE M -20 PACE B 24 PACE A -18 ARAN. IN PLC PACE U30AF AAF124B AAF4H4B LOREN COOK 12W -17D BTU /HR 1,119,000 785,000 387,000 DC GENERAL NOTES: CFM 20,000 21,600 6500 6,500 21 ,600 6,500 1.500 • EXT. S.P 3/4 3/4 STM 1B /HR 785 SUPPLY GRILLE: TITUS 301 RS.SS, 24" X 12" STAINLESS. FIRE DAMPER: RUSKIN CFD -2W, 24" X 12" 25 40 EXHAUST GRILLE: SURFACE MOUNT PERF, 30" X 18" STAINLESS. FIRE DAMPER: RUSKIN D1BD2GV, 30" X 18" BACKDRAFT DAMPER, RUSKIN CBS7, 24" H X 18" W, 14 GA GALV STL FRAME, GALV STL BLADES, PLT'D STL AXLES, STD BEARINGS & UNKAGE, NO SEALS, BOLT HOLES BOTH FLANGES. CONSTRUCTION NOTES: REPAIR DUCT PENETRATION TO MATCH EXISTING WALL. REMOVE EXISTING 16 FT DOOR FOR WALL PENETRATION OF NEW DUCTOWRK. SEE SHEET 1M10. Ma i -2.0 c1T SEP 2 52E1.'S PEW CENTER a RRLNY REVeSeg JCO NO. DM NO. • 1 IMIOR HWS&R MOTOR GPM HP 3-;0ti KEY PI 9- 101.1 - TUTOR 10 25 7.5 1/3 RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY CHANGES FROM THE DESIGN. RALPH SQUIRES, 206- 947 -4706, M/C 46 -87 CLOSE VALVES AND INITIATE ACTION FOR BOEING TO SHUT OFF AND LOCK OUT ALL UTILITIES FEEDING EXISTING M.U. AIR HANDLER AH1 D03A (PACE B -20) AND ABANDONE UNIT IN PLACE. BOEING TO DO LOCK -OUT TAG - TRY -OUT PROCEEDURE. DISCONNECT AND REMOVE DUCTWORK FROM AIR HANDLER AH 1 D03A (PACE B -20). REMOVE EXISTING CHAIN HOIST, COMPLETE WITH OVERHEAD MONORAIL AND SUPPORT STRUCTURE. TRANSFER TO BOEING FOR RELOCATION. CONTACT ART WHITSON (206- 930 -0645) FOR REMOVAL. - EVOVAL 3PAW\ Gi 3 ILA 1 HEATER FOR EMERGENCY SHINIER 54742604 WAR RIIS asE 08/19%06 SAT I I+t1ISIoT1 L 1 EMERGENCY SHOWER FOR MUM 54742602 MONO RIIS N 1 TEST. 3 PAIR. STD DUPLEX WC OUTLETS REMOVE JOGGLE AND PUNCH PRESSES 17580781 RRS 1 RIPS 56554(00 RAMS RIIS 5561290001 WAR RWS P 1 COMP AIR FOR TPAIK J 09/08/05 01.12.06 021306 03.16.06 sv 0 R J I STIALL BREATHING I1R 4566313 -00 REVISE A & C* FOR NEW M.U. AHU 566282 -01' RELOCATE AUTOCLAVE & TANKS 140735 -04 M .w IIG CI TO A DINE TANKIN4E 54742600 M. 1J11C WPRIAUT RMS RIPS RWSPRAW RATS oat 04.26.06 07.18.06 04/06/05 05.31.05 �BOE /Na' `CHIECTIED WPROVED ACCEPTABILITY THS OE S/04 NO/011 SPECIFICATION 6 APPROVED APPRONEO BY OEF1. OA1E Mum 8/3/92 a,ennf CONSTRUCTION NOTES RETURN REDLINED PRINT BACK TO ENGINEER WITH ANY CHANGES FROM THE DESIGN. RALPH SQUIRES, 206 - 947 -4706, M/S 46 -87 RAISE APPROXIMATELY 20 LF OF 2" COMPRESSED AIR PIPING TO CEILING LEVEL TO AVOID INTERFERENCE WITH NEW DUCTWORK. RAISE APPROXIMATELY 20 IF OF Y" CW PIPING TO CEILING LEVEL TO AVOID INTERFERENCE WffH NEW DUCTWORK. REMOVE EXISTING 4" CW DOWNSTREAM OF EXISTING VALVE. INSTALL BLIND FLANGE AND PATCH WALL. DISCONNECT CW PIPING FED FROM REMOVED 4" CW AND RECONNECT TO NEW 2" PIPING AS PER INSTALL NEW 2" COPPER CW PIPING FROM EXISTING 4" CAPPED VALVE AND RECONNECT EXISTING PIPING WHERE SHOWN. RUN NEW PIPING IN PAINT SPRAY ROOM AT CEILING LEVEL TO AVOID INTERFERENCE WITH NEW DUCTWORK. PROVIDE 2" V1CTALIC CLEARFLOW DIELECTRIC FITTING AT PIPING CONNECTION. RECONNECT PIPING THAT WAS PREVIOUSLY CONNECTED TO THE OLD 4" LINE TO THE NEW 2" CW PIPING PROVIDE 2' PLUGGED BALI. VALVE AT THE END OF THE NEW 2' CW PIPING RUN. REMOVE AND DO NOT REPLACE 4" CAPPED CW RISER. REMOVE ABANDONED PIPING TO SPRAY BOOTH. PROVIDE PLUGGED 3/4 BALL VALVE FOR FUTURE OFF OF NEW 2" CW PIPING. 10. INSTALL PIPING LABELS. REFERENCE DRAWINGS f7, 0 0. 0 9 0 0 PLUMBING FIRST FLOOR PLAN BUILDING 9 -101.1 MECHANICAL MASTER COL A -E /1-6 d REMISI iN 'SYMBOL 1M110 JOS NO. D.C. c."°- 9- 101 -11110 !caw No. NR OUTLET VALVE uP POINTING DOWN KOLD -DRAFT ICE MAKER GATE VA. & CHECK VA IN RISER 2" VENT " CAPPED RISER X "CA H WITH 4" CAPPED TEE A X=� cw --�- X" DN. TO PRESS. REGULATOR AND EXTEND BREATHING AIR OUTLETS INSIDE THE PAINT BOOTH CHILLER PLANT BOX (2) BREATHING AIR OUTLETS TO INSIDE THE PAINT BOOTH • M5 3/4" CW TO HYGIENE LAB - SEE DWG 101 -103 a I 2" AIR VENT, S01-40 8~.K. STEEL OVEN 1/2" 1"COPPER . PUMP .. SPD5OH GPM Ulf FT HEAD 1 AIR • DUPLEX AIR OUTLET 1/2" 111110 ER c IMEGEMANN COORDINATOR 1" BALL VALVE & DN. TO PUMP FOR AMINE TANKUNE BENCH 6 EACH VACUUM OUTLETS. SEE MULTIPLE VACUUM OUTLET DETAIL f AIR FILTER (TO SERVE 11110 M532 1'COPPER A 1' 1M1 M518 1 • VALVE W/ VALVE W/ K PLUG PLUG X" CA DN. TO 50 SCFM BREATHING SYSTEM, GRADE -0 MARTECH MODEL 50, PART 175502 ' DUPLD( (TYP. OF 3) 4:i A Y" CW DOWN TO PLUGGED VALVE ON WALL • " cWUPTO 2N0 FLOOR 6" AIR 4" CW �- 6'A LOOP Ct. "-- 4 "CW LOOP STAIR 110 APPED CW RISER CW I F i i VALVE W/ PLUG A VAC 3 /4 "CW & 3/4 "A ON TO VALVES 7' -0" AFT 1 1M110 M515 t 2" • c1" VAC t ok-ivt FIRST FLOOR PLAN SCALE: 1/8 " =1' -0" RteV CM Of 111KM SEP 2 5 LL' FE11T CS T • LL LIVL) - A - BA - CW - - HW- - PW - - IWP- --- V — RWL COMPRESSED AIR BREATHING MR DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY PROCESS WATER INDUSTRIAL WASTE PUMPED VENT RAIN WATER LEADER SANITARY WASTE GENERAL NOTES 11> > REDUCED PRESSURE BACKFLOW PREVENTER: 3/4" WAITS SERIES 909 EMERGENCY SHOWER /EYEWASH: HAWS 8300CRP ET> ELECTRIC TANKLESS WATER HEATER, 72 KW, 2 -STAGE FOR SHOWER /EYEWASH, NEMA 4 ENCL., 480 /3/60; EEMAX 11 EX720T12 -EFD /COMBO -NEMA 4 111116 111122 111123 111128 111129 111130 111131 111134 111135 111136 111139 114112 111113 111118 111124 111119 111125 111140 111141 111114 111120 114126 111132 111137 114142 111145 111115 111121 111127 111133 111138 111143 111146 9-101.1 KEY PLAN SCALE: N TS 0 0 0 • SAC A ROOM INSTALL PAW BOOTH MU PHU 566282 -01 BY s *Ken RMS 1 DUE 06.01.06 SYM RENS= sr APPRO4D DUE Q�BOE /Na• ACCEPTABILITY DS (ISM PMD/OR SPEC/1GAT M 6 APPROWD APPROVED BY DEPT. CATE WAIN D. HOME MEM DER O VILA out 12/2/98 12/2/98 APPROVED SvB�r13tF RRE 1ST RR. PROCESS PIPING PLAN - GAS BUILDING 9-101.1 MECHANICAL VASTER COL A -E /1 -6 D.C. CONSTRUCTION NOTES: REMOVE PIPE CAP AT EXISTING 2' GAS BRANCH VALVE AND RUN NEW 2" GAS PIPING TO NEW AHU ON ROOF. CONTACT SITE SERVICES MAINTENANCE TO REMOVE LOCK —OUT AND TAG FROM VALVE. SUPPORT PIPING 10' -0" O.C. (MINIMUM) CONTACT SITE SERVICES MAINTENANCE TO REMOVE LOCK —OUT AND TAG FROM VALVE. CONTACT SITE SERVICES MAINTENANCE TO PROVIDE NEW LOCK AND TAG FOR EXISTING CLOSED VALVE. 010 143117 REIND R 566282 -01 swat 1M210 J08 NO. ONG »a 9- 101 -114210 08.01.06 carp NO_ STAIR "A" FROMDE BOTTOM OF O'ITINUATION ' 6" AIR (REF) 114210 9432 HPS (REF) VALVE CLOSED AND TAGGED OUT � 2 . GAS TOMU AHU 04 UP • • El 1 El L El El El 4" NATURAL GAS (VALVE 7 FT AFT) 2" GAS TO MU AHU ON ROOF. 2"X1' -0" CAPPED DIRT LEG Al RISER. SEE DWG RFM10 FOR ( STAIR • 110 UTILITIES FROM TUNNEL 12 BELOW 1 • 1. 1‘1 -�o� MEASURED GAS PRESSURE AT CONNECTION POINT IS 28 PSI. HEO8'itu GUY OF71114'tlLA 2 52 9-- 01.1 KEY PLAN Pahlif CENTEF SOLE: NI S. • LEGEND: GENERAL NOTES: s ASBESTOS NO1IRCATIOIt A good (alb survey of the work oreo hos been conducted and osbestos containing material wos not discovered thot would be involved in the construction of this project. Do not remove, domoge cc disturb any asbestos material adjacent to the work area Please contoct Boeing Facities Department if asbestos contoi g material is domoged or dscovered thot is required to be removed to support work. The following moterids in the areas odjocent to this job ore assumed to be positive for asbestos: FLOORmES dr Pp( lisutooN T5 11421 114216 111222 114228 114229 1M2.3 114239 114211 1M212 114217 114223 114218 11421.1 114214 111224 11422 111226 114230 11423 114232 114235 1M2 111237 111240 11424 111242 11424 111245 11421 114220 114215 114221 114227 114233 114238 111243 1 14246 \\- TOI\;W22o s mums 8/3/1%2 & D JUL 23 i • STAIR "A" m A SET UP PAINT MOW AREA 6 P1WT BOOTH WU P U SPINDLE SANDER 4566508 -O 566282 -01 9 -91/2 ` 9 -91/2 9-9 1/2 2 -1/2 9 -9 1/2 9 -9 1/2 2 -1/2 07.30.06 •P.00. 1' LOW P01NT 0 1' ON TO AUX DRAIN VALUE 2 1/2' 2 1/2' &&& 111111 1111J•''ll 1111 :�' ■71■ 17!/ s1Z1■ ■_ 7 11•1v 111111&" 11 1 t!111,' •' n1 1:rr .� 111117-',A.; 11/17!•' FIRE PROTECTION - PLAN V1EW 1M260 B I 32- 008012 145CF14 e tS • • 1.500 SP, RE MAIN RISER 120W VA1_W SV-908 lig I I I I I I I EFET• riliN Mil 5 mill - i1 ■ 1142 I � 0 0 0 BOE /NC' STAIR 0 1 2. 0(9 - 7011 MECHANICAL MASTER BUILDING 9.101 COL. A-E/1-6 LEGEND: - (EXIST) STANDARD SPRINKLER, PENDANT (165' • UNLESS OTHERWISE NOTED) ---0-- (NEW) STANDARD SPRINKLER, PENDANT (165' UNLESS OTHERWISE NOTED) -0•- (EXIST) STANDARD SPRINKLER, UPRIGHT (165' UNLESS OTHERWISE NOTED) -0-- (NEW) STANDARD SPRINKLER, UPRIGHT (165' UNLESS OTHERWISE NOTED) 6 T'5)"( SPRINKLER PIPING, SIZE AND SLOPE TO LOW POINT DRAIN SPRINKLER RISER (ALARM VALVE OR UPPER FLOORS WATER MOTOR GONG PIPE HANGER 2 -WAY EARTHQUAKE BRACING 4 -WAY EARTHQUAKE BRACING CONSTRUCTION NOTES: RETURN REDLINED PRINT BACK TO ENGINEER WITH ANY CHANGES FROM THE DESIGN. RALPH SQUIRES, 947 -4706, M/C 46 -87 INSTALL NEW 1142" FIRE SPRINKLER BRANCH TAP INTO THE 6" SUBMWN AND RUN 114" PIPING TO (5) NEW SPRINKLER HEADS UNDER PAINT BOOTH MU DUCTWORK IN SPRAY ROOM. INSTALL (5) NEW UPRRIGHT 155 DEGREE FIRE SPRINKLER HEADS WITH SPRINKLER GUARDS BELOW NEW MAKE -UP SUPPLY DUCTWORK AND DISCHARGE PLENUM. INSTALL 12"X12" 18 GA GALV. STEEL HEAT COLLECTORS CENTERED ABOVE (4) SPRINKLER HEADS AT DISCHARGE PLENUM. HEAT COLLECTORS SHALL NOT INTERFERE WITH PLENUM FILTER REPLACEMENT. INSTALL AND LABEL 1" PLUGGED AUX. DRAIN VALVE 5'6" AFF. 5. FABRICATION AND INSTALLATION OF THE FIRE PROTECTION PIPING SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN NFPA CHAP. 13 AND FM CHAP. 2, SECTION 8. JOINT COMPOUND OR TAPE (NOT BOTH) SHALL BE APPLIED ONLY TO MALE THREADS. 6. NOTIFY BOEING FIRE DEPARTMENT 24 HOURS IN ADVANCE OF DOING WORK (206)655 -7700. USE NEW FIRE SPRINKLER HEAD, 155'F RATED, VIKING MICROMATIC MODEL "M ", 1 /2 "NPT, 1/2" ORIFICE, 5.6 K- FACTOR UPRIGHT HEADS. THE SHUT -OFF VALVE SV1908 IS LOCATED AT COL. B/1. 7. LABEL ALL NEW SPRINKLER PIPING REFRANCE DRAWINGS: 109 - 101 - 4576 -M1 FIRE PROTECTION (ORIGINAL MYLAR) 9- 101- -1 M260A DRY SPRINKLER PIPING 9- 101 -14514 FIRE PROTECTION DETAILS Y q Y 111266 114261 114267 1M262 114268 111272 114273 114289 11+1274 114278 114279 114280 114290 114263 114269 114275 114281 114291 G k 9 -101.1 KEY PLAN 114264 114270 114276 114282 114292 114265 114271 114277 114283 14284 114285 114286 114287 ,114288 Tin L ©s //ill ER 1 1 BEV. CENTER, i A DOG NO. 9- 101 - 114260 COW NO. 07.30.06 1 a i L Y N STAIR " 1N1 0 0580 MACRO BRAKE 80 TON PRESS 1 1/4', 1 /2'CW ON TO THE OVEN 1 1 /2' CWDNTO 4 -- (2) BREATHING AIR OUTLETS TO INSIDE THE PAINT BOOTH CHILLER PAINT BOX • ON TO 3' -0 AFF ERMERGENCY EYEWASH '- EL +31.75' EL +31.75' 2" CW 11111E1111111 4' 1, ■ i / I I I M iW1/ii�, - - - -- - +��+ 2 A , 74fr Y2 H1 CW © X" ON. TO PRESS. REGULATOR AND EXTEND a BREATHING AIR OUTLETS ' ) I _ INSIDE THE PAINT BOOTH .+1/74/71/2976/ • .. 6 EACH VACUUM OUTLETS. SEE MULTIPLE VACUUM OUTLET DETAIL AIR FILTER (TO SERVE 111110 M532 EN' AI RTC LATOR VIA J X CA ON. TO 50 1041 I] M518 SCFM BREATHING SYSTEM, GRADE -0 MARTECH MODEL 50, PART 175502 PROPRESS FITTINGS M1 0 M518 VALVE VALVE W/ PLUG PLUG . Y4. AIR OUTLET VALVE UP POINTING DOWN KOLD -DRAFT ICE MAKER GATE VA. & CHECK VA. N RISER 2' VENT CO NP AR FOR AMN& ENERGEICY SKATER FOR TANQANE HEATER FOR EVERGENCY SHOMER MST_ 3 PAIR STD DUPLEX VAC OUTLETS REMOVE ,OGLE AND PUNCH PRESSES • 2' AIR VENT. sctl - 40 8LK_ STEEL 54742602 54742604 1758078 5655so00 55612900 PUMP SP0501I GPM FT HEAD HARR HARR RWS RAS WRR • Apps RWS RWS RNS RWS t 08/19/06 09 /O8 /O6 01.12.06 02.13.06 03.16.06 1M110 au VALVE do r ON TO PUMP SAM 0 NSTIIIL BREATHING AIR CW TO NOOK 10181INE MOON I RELOCATE NTOCUNE & TANKS FOR ALODINE TANKUNE 4566313 -00 REVISE A & CW FOR NEW KU. NU 566282 -01 54742600 140795 -04 $r Y.1e% RWS IVRR UMW • RIIS RWS RIPSAW 04.26.06 07.18.06 04/06/05 05.31.051 1 2 t EL +3304' Q�BOE /N6' '- • Y "CWUPTO 2ND FLOOR 6" AIR 4" CW � - 6'A LOOP -- 4'CW LOOP N. 4 z ca- STAIR 110 APPED CW RISER CW v- VALVE W/ PLUG + VPC 3 /4 & 3/4"A ON TO VALVES 7' -0' AFF 1 1M1 ACCEPTABILRY 1E9GN AND/OR SPECFECUION 15 APPROVED PPPROYED BY • T06'AFF OEpT_ VAC M515 CW --t --t 6' A � 1' VAC e t OrITE grommoN M. DODOS CHE MED APPROPmED MPPROCID 4xTE 8/3/92 Nto19.1.0 FIRST FLOOR PLAN SCALE: 1/8' =1' -0' BUILDING 9 -101.1 MECHANICAL MASIER COL A -E /1-6 LLULIVU CONSTRUCTION NOTES RETURN REDUNED PRINT BACK TO ENGINEER WITH ANY CHANGES FROM THE DESIGN. RALPH SQUIRES, 206 - 947 -4706, M/S 46 -87 RAISE APPROXIMATELY 20 LF OF 2" COMPRESSED AIR PIPING TO CEILING LEVEL TO AVOID INTERFERENCE WITH NEW DUCTWORK. RAISE APPROXIMATELY 20 15 OF Y" CW PIPING TO CEILING LEVEL TO AVOID INTERFERENCE WITH NEW DUCTWORK. REMOVE EXISTING 4" CW DOWNSTREAM OF EXISTING VALVE. INSTALL BLIND FLANGE AND PATCH WALL. DISCONNECT CW PIPING FED FROM REMOVED 4" CW AND RECONNECT TO NEW 2" PIPING AS PER INSTALL NEW 2" COPPER CW PIPING FROM EXISTING 4" CAPPED VALVE AND RECONNECT EXISTING PIPING WHERE SHOWN. RUN NEW PIPING IN PAINT SPRAY ROOM AT CEILING LEVEL TO AVOID INTERFERENCE WITH NEW DUCTWORK. PROVIDE 2 VICTALIC CLEARFLOW DIELECTRIC FITTING AT PIPING CONNECTION. RECONNECT PIPING THAT WAS PREVIOUSLY CONNECTED TO THE OLD 4" LINE TO THE NEW 2 CW PIPING PROVIDE 2 PLUGGED BALL VALVE AT THE END OF THE NEW 2 CW PIPING RUN. REMOVE AND DO NOT REPLACE 4' CAPPED CW RISER. REMOVE ABANDONED PIPING TO SPRAY BOOTH. PROVIDE PLUGGED 3 BALL VALVE FOR FUTURE OFF OF NEW 2" CW PIPING. 10. INSTALL PIPING LABELS. REFERENCE DRAWINGS 4 0 9 0 0 PLUMBING FIRST FLOOR PLAN - A - BA — CW - - PW - --- IWP - - RWL- - SAN GENERAL NOTES n REDUCED PRESSURE BACKFLOW PREVENTER: 3/4" WATTS SERIES 909 1 2 > EMERGENCY SHOWER /EYEWASH: HAWS 8300CRP F 3 > ELECTRIC TANKLESS WATER HEATER, 72 KW, 2 -STAGE FOR SHOWER /EYEWASH, NEMA 4 ENCL., 480/3/60; EEMAX 1 EX720T12 -EFD /COMBO -NEMA 4 c ojED rlivncTiONV 5206 Walt 111116 111117 1M1221 111123 111128 111139 1M112 111118 111124 111129 111130 111134 111135 111140 111113 111119 111125 111141 111114 104120 104126 111142 11+1145 111115 111121 114127 111131 1M132 104133 111137 111138 111143 111146 D.C. 9 -101.1 KEY PLAN WALE N TS_ CURRENT REVISION JOS RO. MGM. 1. • COMPRESSED AR BREATHING AIR DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY PROCESS WATER INDUSTRIAL WASTE PUMPED VENT RAIN WATER LEADER SANITARY WASTE 1M110 a1t 9- 101 - 14110 COMP NO. • 4 ..most■ REVISION BY WOMB VW SYM REV610N 811 ~AD OM I RELOCATE S EEI /OEM /OEM J4180148 -02 KGP RMS/OOT 12.4.98 1 8 CE TS/'SW REARR IGE 006 4140797-06 KNOW RNS 11.02_06 C DRY PIPE TO SOLVENT 800TH DUCT SPK1R 13024004 WIRR 12/06/06 0 PPM 600TH MU NJ 566282 -01 RC R11S 07.30.66 2' DRY SPRINKLER UNE 2w DRY SPRINKLER LINE TO SKYBRIDGE SEE DWG. 000 - 4017 -M1 UP STAIR 1 . . NMI IN : 1• crf I • 1 LOW POINT DRAI LOW POINT DRAIN DESPATCH OVEN 2' DRY INKIER 1's LINE 1, _ TO OVENS AT COL. D/3 1 AUX_ DRAM BELOW w7650T GRNEL ISSUE D 4' DRY VAL TYCO MODE v -1 1M2� ►AIM514 i 1 A Ei P.O.0 FOR NEW 1" SPRINKLER TO MU AHU ON ROOF TO BE AT 2" PIPING ABOVE 4 "X2" REDUCER ON DRY RISER 3 1 1" UP TO PAINT BOOTH MAKE -UP AHU ON ROOF )4" NM ■ • • r FIRE MAIN RISER VALVE SV -908 i • 1 M260A 111532 1 DN. TO OVEN/2 w/ ONE VICTAUUC STYLE 77 FLEX COUPLER TO ISOLATE OVEN FROM THE BUILDING DN Q;LBOE /NO• STAIR 110 OVEN 112 OVEN 11 1 DN. TO OVEN /1 W/ ONE VICTAULIC STYLE 77 FLEX COUPLER TO ISOLATE OVEN FROM THE BUILDING PLUGGED TEES 1 1 1 AUX. DRAINS ACCEPTAQIUTY MIS DESIGN 110/02 SPECF1GI110N IS 11PF'i U D APPROWED BY DEPT_ GATE 2 1M2605' 4 n CHECKED rwPRObEO fr1019- PLAN SCALE: 1 /8" = 1' — O' 6 2. LABEL NEW PIPING T,‘ FIRRE PROTECTION — PARTIAL PLAN BUILDING 5 -901 MEf.FfAMCAL VASTER COL. A -E /1 -6 LEGEND: --�-- (EXIST) STANDARD SPRINKLER, PENDANT (165' • UNLESS OTHERWISE NOTED) --0-- (NEW) STANDARD SPRINKLER, PENDANT (165' UNLESS OTHERWISE NOTED) -0- (EXIST) STANDARD SPRINKLER, UPRIGHT (165' UNLESS OTHERWISE NOTED) -0-- (NEW) STANDARD SPRINKLER, UPRIGHT (165' UNLESS OTHERWISE NOTED) SPRINKLER PIPING, SIZE AND SLOPE TO LOW POINT DRAIN SPRINKLER RISER (ALARM VALVE OR UPPER FLOORS WATER MOTOR GONG PIPE HANGER 2 -WAY EARTHQUAKE BRACING WA ' AR GENERAL NOTES DEV. CENTER, WA AKE : RACING 1. FABRICATION AND INSTAUATION OF THE FIRE PROTECTION PIPING SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN NFPA CHAP. 13 AND FM CHAP. 2, SECTION 8. JOINT COMPOUND OR TAPE (NOT BOTH) SHALL BE APPLIED ONLY TO MALE THREADS. 2. DRY SPRINKLER PIPING SHALL BE GALV. STEEL SCHEDULE 40 ASTM A53B. 2. NOTIFY BOEING ARE DEPARTMENT 24 HOURS IN ADVANCE OF DOING WORK (206)655-7700. THE SHUT -OFF VALVE SVI908 IS LOCATED AT COL. B /1. CONSTRUCTION NOTES: INSTALL 1" SCH 40 GALV STL SPRINKLER PIPING TO SPRINKLER HEAD IN NEW MU AHU ON ROOF. HORIZONTAL RUNS SHALL HAVE MINIMUM OF X" PER 10 FEET TOWARD DRY VALVE. SEE 1M260 AND RFM10. 9 -101.1 KEY PLAN 4 4 4 CURRENT RE SPON 566282 -01 XXI Pa COG ND_ • 1M260A 1M266 114272 111261 1M262 114267 111273 114278 114279 111280 11284 111289 111268 111274 114263 111269 111275 111285 111285 111290 111291 111294 1 114264 114270 114276 111282 111287 111292 111295 114265 111271 111277 111281 114283 111288 111293 1!1296 9- 101- 1II1260A BEGE►'VEu Zll: ^ :T1IKE�= SEP 2 5 20(16 PER 1111( TER COW NO_ 07.30.06 9 SOUIRESR: 7/30/2006 1:3911 P0.4 • sTu A WALL t EN4 OOW REMOVE .IOGCLE PRESS 4 HPS 6 1 32- -008012 14 5 CFM 1. 1 R. y am 1 w ru r L LiEVE MN ~ ; :1J w ■1Jiel 4 1 s',ii 1 SPINDLE 1 SANDER 1- 0 PUMPED COM) 140795 -01 565546 -O RIIS RIS C DOE 1 06.28.05 02.13.06 Cr U 2" HPS �- - 1 -1 /4" COND 2 -1/2 - 1/2' CAPPED CkNNS&R SIMON 4" -3" PUMPED COND 1 1/2' • El CHWS ! � - 1" CHWR 1 1/2' 3 3 4" HPS AND FROM TUNNE BELOW 3" PUMPED COND 4" HPS 3 "P 12 - r TO AUTOCLAVEI f TT ° TT - T T �TT = TT TT - T T TT I TT = = TT 1 1 4" HPS • 1 1 p rAPEZAW* 3" HPS TO AHU 11'— 6" HPS FRO ,, TUNNEL 112 TO 2ND FLR 4" GAS (RE 6" AIR (REF 4" HPS FRO TUNNEL # 12 CONDEN ! TE RECEIVE AI 16 u u " HPS 3 /4" COND " HPS 1 1 1 1 1 1 3* PUMPED COND ? NDENSATE .. ..1..`!., 1. ..,.. 1 1 1 1 c ACCEPTAMUTY HWS 2" HWS 2" HWR 1 -3 3' -0" HPS _• i /MIMI NIWOR CHEMED SPECFICOON 6 APPROVED yes sf DEPT. DATE a acm APPROVED — 1" PUMPED CONDENSATE FROM 9 -103 PC 1 1 /2" COND 2" HWR 3 "HWS P COND 4" HPS l�J 3" PUMPED COND Mbbw1-04 MECHANtCAM MASTER HVAC PIPING - PLAN VIEW TT‘ BUILDING 9 -101.1 COI. 1 -6 /A —E DIV. CENTER, WA • LEGEND HPC HPS - STM HWS-- - - HWR CHWR -- -- CHWS COND - - P COND— GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES RFTTRF o\ LY TT P 11166 111167 11172 11173 11178 11179 11162 11168 11174 11180 11163 11169 11175 11181 11186 1 1 11184 11185 11189 11190 11191 11194 9 -101.1 KEY PLAN 11164 11170 11176 11182 11187 11192 11195 11165 11171 11177 11183 11188 t CURRENT RIDASl01i/ 565546 -00 >a. c. CONDENSATE STEAM (HIGH PRESSURE) STEAM SUPPLY (HIGH PRESSURE 125, 250 PSIG) STEAM SUPPLY HEATING WATER SUPPLY HEATING WATER RETURN CHILLED WATER RETURN CHILLED WATER SUPPLY CONDENSATE PUMPED CONDENSATE 1M60 9 9- 101.1 -1M60 Ti1K4 RA 52006 (ENTER 02.13.06 0 a 1 0 de 1 • • A B C 0 RECORD I A1101; CE 1S/S11 REMWANGE GOENS DENSON REUSE CUTOFF sm I SOMRGE PANT 800TH YU MU 1 "0 UNLESS OTHERWISE NOTED ON PLANS DETAIL NTS 0 0 DC O aC • • PENDENT PENDENT SPRINKLER HEAD SPRINKLER HEAD SOLVENT SPRAY BOOTH AND CUTOFF SAW EXHAUST DUCTS n SCALE: 1/2' =1'-0• ps s�a � iW26� SR M140797 -06 AMONG SPRAY BOOTH & CUTOFF SAW DUCT 060L DTL 13024004 WAR 13024004 I*R 566282 -01 RNS 6FTMIN. GS KR RPS MIS RNS i DUE 0615.93 11.02.05 12/05/05 01/13/06 08.03.06 1) FAN Fr> UPRIGHT SPRINKLER HEAD CROSS —MAIN SUSPENDED CEILING 2M260,2M261,2M2661 M514 18" DIA GALV DUCT SOLVENT SPRAY BOOTH DBMS 4 "X2" VICTAULIC REDUCING ' LG 2" TO SKYBRIDGE a' DIA GALV DUCT FROM HOSE CUTOFF saw 1 - POINT OF CONNECTION FOR JAN 3 2006 CHANGE ORDER 1' 01" TO SOLVENT 4" TYCO MODEL DPV -1 DRY VALVE SCALE: 1/2 " =1' -0" L> NEW 1" TO PAINT BOOTH MU AHU MTh 2 "X11" VICTAULIC REDUCI \� OVENS P.O .0 FIRE PROTECTION RISER rA iuzsonjus,< APPAitElAlig* dor d• --- -- 8" ARE SPRINKLER 1 VALVE, SV -908 VICTAUUC c++ RIGID STYLE 07 COUPLING FINISH FLOOR ACCEPTAB1U Y MIS (DESIGN MAR SPECi1CA11ON 6 /EPROM) IPPROWED Of OWL NDRPAIN S. ROSSE V. CAMITIS CtirOCED G.G. 99TH MD K. RUM 1`0 IGOTE NIBCO KT65UL 2 "OX12" NIBCO KT65UL AUX. DRAIN /INSP. TEST SCALE: NONE iss 2. GENERAL NOTES VANE AXIAL FAN, NEW YORK BLOWER SIZE 18 ARR 9 -M, FOR FLAMMABLE SOLVENT FUME SERVICE, AMCA TYPE B SPARK RESISTANT CONSTRUCTION, 2626 RPM BELT DRIVE, EXTERNAL 3 HP PREMIUM EFFICIENCY 480V/3/60 TEFC MOTOR. 4320 CFM 0 1.5" WG SP. FABRICATION AND INSTALLATION OF THE FIRE PROTECTION PIPING SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN NFPA CHAP. 13 AND FM CHAP. 2, SECTION 8. JOINT COMPOUND OR TAPE (NOT BOTH) SHALL BE APPLIED ONLY TO MALE THREADS. 3. NOTIFY BOEING ARE DEPARTMENT 24 HOURS IN ADVANCE OF DOING WORK (206)655 -7700. CONSTRUCTION NOTES RETURN REDLINED PRINT BACK TO ENGINEER WITH ANY CHANGES FROM THE DESIGN. RALPH SQUIRES, 947 -4706, M/C 46 -87 INSTALL 1" SCH 40 THD'D GALV STL SPRINKLER PIPING TO SPRINKLER HEAD IN NEW MU AHU ON ROOF. HORIZONTAL RUNS SHAD. HAVE MINIMUM OF h PER 10 FEET TOWARD DRY VALVE. SEE 1M260A AND RFM 10. 1FA260A� M514 FIRE PROTECTION DETAILS BUILDING 9 -101 MECHANICAL MASTER LEGEND 7. LABEL ALL NEW SPRINKLER PIPING ammo ttEve.son sr�eo� 566282 -01 SOS ND_ DEV. CENTER, WA NIG e.u. • M514 9- 101 -M514 t3Ec &JEU CITY nr-Tt00 :01: SE? ..JLi PEaWI CST Efs DATE 08.03.06 WIMP Teo • a 1 4 !n l4SUiEt MIT BOOTH MU AHU 566282 -01 Or MS IPPROAD R S Mt 08.03.06 ign TE*90s Sr 11PPS OVID OM ME t • PROVIDE ANGLE BRACKETS ANCHORED TO PRECAST CONCRETE WALL SIMILAR TO EXISTING SUPPORTS ON ADJACENT DUCTWORK. (TYP) 90/35 FLEX CONNECTION 1 " DRY SPRINKLER 2" 60/42 1" DRY SPRINKLER SEE 1M260 • 1 286 DEGREE F DRY PENDENT SPRINKLER HEAD WITH SPRINKLER GUARD. PROVIDE SEALED FLANGE AT PIPE PENETRATION. 11 n 1 74/42 GAS SEE 1M210 L 60/42 r DRY SPRINKLER PERFORATED 16 GAUGE GALV. STEEL PLATE. 51% OPEN, STAGGERED 0.1875" DIAMETER HOLES SUPPORT DUC1WORK AND PLENUM FROM CEILING STRUCTURE IN MANNER SIMILAR TO EXISTING AREA DUCTORK. USE UNITSTRUT TRAPEZES 10' -0" 0.C. AND BRACE TO WALL. SECTION 1p =1'—o• ma7 ARNo AHRD1 WEATHER -RITE TOT 230 HH DIRECT FIRED MAKE -UP AHU 25 HP 460 v 3 PH, 60 Hz 42,000 CFM AT 1.4" TSP 3,250,000 BTU 12" W.C. - 5 PSI GAS PRESSURE SEE STRUCTURAL DRAWINGS FOR SUPPORT AND PLATFORM DETAILS FINISHED FLOOR ArmsrAvw REINFORCE BASE OF PLENUM AS REQUIRED TO SUPORT DUCTWORK AND (UL4IP ATE ANY DEFLECTION OF 1 UER RACK FILTER ACCESS TO BE UNOBSTRUCTED. BOTTOM OF PLENUM TO BE PUROLATOR HI -TRAK 3X20 FILTER RACK. (60 NOMINAL 2'X2'X2" PLEATED FILTERS). PERFORATED PLATE PLENNUM WALL 1 "x1 x16 GA. ANGLE AROUND PLENUM AND ACROSS PLENUM 4' -O" 0.C. SECURE TO PLENUM W /SHT MTL SCREW tvi o -rib 1. PATCH AND SEAL AROUND ALL WALL PENETRATIONS INTO THE PAINT SPRAY ROOM AND CAULK WITH FIRE RATED COMPOUND. LEGEND: GENERAL NOTES: CONSTRUCTION NOTES: RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY CHANGES FROM THE DESIGN. RALPH SQUIRES, 206 - 947 -4706, M/C 46 -87 INSTALL NEW 60 "X42" DUCTWORK FROM MAKE -UP AHU AHRD1 ON 9 -101 ROOF DOWN THE NORTH SIDE OF THE BUILDING AS SHOWN. SEE STRUCTURAL DRAWINGS FOR DUCT SUPPORTS. DUC1WORK TO CONFORM TO SMACNA STANDARD FOR 2" W.C. PRESSURE CLASS. PROVIDE OPENING IN PRE -CAST CONCRETE WALL AND PENETRATE WALL WITH NEW 60 "X42" DUCT. FINISH AND SEAL WALL AROUND DUCT PENETRATION. INSTALL 60'X42" DUCT TO NEW DISCHARGE PLENUM. TOP OF DUCT TO BE 19' -6" AFF. FABRICATE AND INSTALL NEW DISCHARGE PLENUM. BOTTOM OF PLENUM TO BE 16GA PERFORATED PLATE W/ STAGGERED HOLES AND HAVE PUROLATOR HI -TRAK FILTER RACK INSTALLED BENEATH. ALSO SEE DRAWING 9- 101 -11110. TOP OF PLENUM TO BE 19' -6" AFF. INSTALL NEW AHU ON ROOF. SEE STRUCTURAL DRAWINGS FOR SUPPORT. SUPPORT DUCT FROM AHU PLATFORM © BALANCE EXISTING PAINT BOOTH EXHAUST AND MU AHU TO 42.000 CFM. INSTALL NEW 2' GAS PIPING TO NEW AHU ON ROOF. SUPPORT PIPING 10' -0" O.C. (MINIMUM) INSTALL 1' SCH 40 THD'D GALV STL SPRINKLER PIPING TO SPRINKLER HEAD IN NEW MU AHU ON ROOF. HORIZONTAL RUNS SHALL HAVE MINIMUM SLOPE OF fit' PER 10 FEET TOWARD DRY VALVE. SEE 1M260A AND RFM10. REMil Eu $IN fr. i 0(%V i ri SEP 2 5 zeti. PEW! CaTEF: ACCEPTABILITY lids DESIGN m0/OR SPECwiCAION 6 IPPR MD DRIE IPPROJED BY COM °MN RaS a+EaCED ENCIKER RIPS aEoD PPPRMED OPJE 07.29.06 08:01.06 1 PPPROVED 1 SUEMRE SECTIONS AND DETAILS VIRE PAINT BOOTH WAKE -UP BUILDING 9 -101 MECHANICAL MASTER COL C -D /1 -3 DEV. CENTER, WA OMMMTROMMIN ISYNKL 566282 -01 A sicu JOB NO. ONG NO. 1M532 9 - 101 - 111532 DUE 08.03.06 CORP NO. sYy OUTUNE OF PARAPET WALL WORD DRAWING INSTALL PANT BOOTH MU AHU c1 111111111111111111111 111111111111111111111111111111 INNINInz MI6 1 I ill 1111 I III 11W. 211111111112 MI IN IIII me m - -1 MN MI If X III MI _ NM PM - / w MR If En MI If If 1 - -_3 - IN OD - If MN — MN MN 2" GAS UP FROM FIRST FLOOR. SEE DWG 1M260 1' DRY SPRINKLER UP FROM FIRST FLOOR. SEE DWG 1M260A XISTING ROOF STRUCTURAL SUPPORT BEAMS. SEE STRUCTURAL DRAWINGS -- 2" GAS CONNECTION TO AHU FM COMPLIANT REGULATOR AND GAS TRAIN. PROVIDE ISOLATION VALVE AND STRAINER AHEAD OF REGULATOR. (5 PSI). 2 1 /2 "CHWS & R 211111111112 mono • —gig G!l1711I111;: MO In IN NM 1111111111 2 "X1' -0" DIRT LEG AT LOTTOM OF RISER RFM10 1M532 PENTHOU (SERVES AH2C 3" DOWN TO AH2C5A N11111111111111111 11111111111111111111111111111 286 DEGREE F SPRINKLER HE SPRINKLER GU PROVIDE SEALE PIPE PENETRA 60/42 MAKE -UP AIR DUCT DOWN TO PAINT SPRAY ROOM. SEE DWG INTO SEE STRUCTURAL DRAWINGS FOR DETAILS OF AHU SUPPORT AND MAINTENANCE PLATFORM FLEX CONNECTION INSPECTION & ACCESS PANEL HINGED ACCESS DOOR (BOTH SIDES) lA 566282 -01 • HUED WATER 1 AMR HANDLING UNIT AH2C5A LINES OUTSIDE AIR PENTHOUSE, MEND PER DETAIL n RFM10 Ik51 el SR RRS PPPROAD • GS KR RUS HWS CHWR 062893 08.03.06 0 0 • 1 AIR HANDLING UNIT AH2B2A OUTSIDE AIR PENTHOUSE, EXTEND PER DETAIL ( RFM10 M511 CONCRETE PAVERS, PERIMETER OF STR. TOPPING, TYP 3" DOWN TO AHINBSA PENTHOUSE (SERVES A 1285A) MATCH LINE — FOR OONTINUAT10N S'EE RF1416 ftf • CAPPED OPENING CC V) 3 3 Z U U —p, BOE /N• v' • HWS HWR i ROOF GRAIN OVERFLOW DRAIN /I H1I 6" WPROVED er HWS CHWR 6 „ CHWS CHWR I'1 111 ACCEPTA6111TY INS CUM Jill► /oR snarl Anon 6 *PPRO t • elbow cw S.ROSSE DATE 823.91 0 CU 4 X1111111111! =11111111112 PARTIAL ROOF PLAN SCALE: 1/8" =1' -0" ROOF PLAN — HVAC AND PIPING BUILDING 9 -101 01SCIPUNE) MASTER COL_ A - /1 - OEV. CENTER, WA • LEGEND: VTR -- CHWS — — CHWR - -Da —►f- LIFT CHECK VALVE PIPE REDUCER BUTTERFLY VALVE GENERAL NOTES: VENT THROUGH ROOF CHILLED WATER SUPPLY CHILLED WATER RETURN GATE VALVE, OPEN /CLOSED 1. ALL CHILLED WATER PIPING IS COVERED WITH FIBERGLASS INSULATION AND ALUMINUM VAPOR BARRIER. CONSTRUCTION NOTES: RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY CHANGES FROM THE DESIGN. RALPH SQUIRES, 206 - 947 -4706, M/C 46 -87 INSTALL NEW 60"X42" DUCTWORK FROM MAKE -UP AHU AHRD1 ON 9 -101 ROOF DOWN THE NORTH SIDE OF THE BUILDING AS SHOWN. SEE STRUCTURAL DRAWINGS FOR DUCT SUPPORTS. DUCTWORK TO CONFORM TO SMACNA STANDARD FOR 2" W.C. PRESSURE CLASS. INSTALL NEW 2" GAS PIPING TO NEW AHU ON ROOF. PROVIDE ISOLATION VALVE AND STRAINER AHEAD OF CONNECTION TO AHU FM APPROVED GAS TRAIN. SUPPORT PIPING 10' -0" O.C. (MINIMUM) INSTALL 1" SCH 40 TWO GALV STL SPRINKLER PIPING TO SPRINKLER HEAD IN NEW MU AHU ON ROOF. HORIZONTAL RUNS SHALL HAVE MINIMUM SLOPE OF Y" PER 10 FEET TOWARD DRY VALVE. SEE 1M260A AND M532. ONG NO. KEYPLAN NO SCALE OT_ CHECKED APPROVED MA • CUSSVOT REM O( SYMBOL 566282 -01 RFM10 9 -1 O1 -READ RECEi iiEu C1OVOcT,Ikv ;1 t s: 2 5 mei PERMIT CETEf OME 08.03.06 • u %%%//// �I i IR"'2 1 1 ,, I 1 I 1 „N I flh1 1 prim I I ! ; = ;Tr.} L 1! I' ! 1 1 ! ! I 1 1 I 1 sYy OUTUNE OF PARAPET WALL WORD DRAWING INSTALL PANT BOOTH MU AHU c1 111111111111111111111 111111111111111111111111111111 INNINInz MI6 1 I ill 1111 I III 11W. 211111111112 MI IN IIII me m - -1 MN MI If X III MI _ NM PM - / w MR If En MI If If 1 - -_3 - IN OD - If MN — MN MN 2" GAS UP FROM FIRST FLOOR. SEE DWG 1M260 1' DRY SPRINKLER UP FROM FIRST FLOOR. SEE DWG 1M260A XISTING ROOF STRUCTURAL SUPPORT BEAMS. SEE STRUCTURAL DRAWINGS -- 2" GAS CONNECTION TO AHU FM COMPLIANT REGULATOR AND GAS TRAIN. PROVIDE ISOLATION VALVE AND STRAINER AHEAD OF REGULATOR. (5 PSI). 2 1 /2 "CHWS & R 211111111112 mono • —gig G!l1711I111;: MO In IN NM 1111111111 2 "X1' -0" DIRT LEG AT LOTTOM OF RISER RFM10 1M532 PENTHOU (SERVES AH2C 3" DOWN TO AH2C5A N11111111111111111 11111111111111111111111111111 286 DEGREE F SPRINKLER HE SPRINKLER GU PROVIDE SEALE PIPE PENETRA 60/42 MAKE -UP AIR DUCT DOWN TO PAINT SPRAY ROOM. SEE DWG INTO SEE STRUCTURAL DRAWINGS FOR DETAILS OF AHU SUPPORT AND MAINTENANCE PLATFORM FLEX CONNECTION INSPECTION & ACCESS PANEL HINGED ACCESS DOOR (BOTH SIDES) lA 566282 -01 • HUED WATER 1 AMR HANDLING UNIT AH2C5A LINES OUTSIDE AIR PENTHOUSE, MEND PER DETAIL n RFM10 Ik51 el SR RRS PPPROAD • GS KR RUS HWS CHWR 062893 08.03.06 0 0 • 1 AIR HANDLING UNIT AH2B2A OUTSIDE AIR PENTHOUSE, EXTEND PER DETAIL ( RFM10 M511 CONCRETE PAVERS, PERIMETER OF STR. TOPPING, TYP 3" DOWN TO AHINBSA PENTHOUSE (SERVES A 1285A) MATCH LINE — FOR OONTINUAT10N S'EE RF1416 ftf • CAPPED OPENING CC V) 3 3 Z U U —p, BOE /N• v' • HWS HWR i ROOF GRAIN OVERFLOW DRAIN /I H1I 6" WPROVED er HWS CHWR 6 „ CHWS CHWR I'1 111 ACCEPTA6111TY INS CUM Jill► /oR snarl Anon 6 *PPRO t • elbow cw S.ROSSE DATE 823.91 0 CU 4 X1111111111! =11111111112 PARTIAL ROOF PLAN SCALE: 1/8" =1' -0" ROOF PLAN — HVAC AND PIPING BUILDING 9 -101 01SCIPUNE) MASTER COL_ A - /1 - OEV. CENTER, WA • LEGEND: VTR -- CHWS — — CHWR - -Da —►f- LIFT CHECK VALVE PIPE REDUCER BUTTERFLY VALVE GENERAL NOTES: VENT THROUGH ROOF CHILLED WATER SUPPLY CHILLED WATER RETURN GATE VALVE, OPEN /CLOSED 1. ALL CHILLED WATER PIPING IS COVERED WITH FIBERGLASS INSULATION AND ALUMINUM VAPOR BARRIER. CONSTRUCTION NOTES: RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY CHANGES FROM THE DESIGN. RALPH SQUIRES, 206 - 947 -4706, M/C 46 -87 INSTALL NEW 60"X42" DUCTWORK FROM MAKE -UP AHU AHRD1 ON 9 -101 ROOF DOWN THE NORTH SIDE OF THE BUILDING AS SHOWN. SEE STRUCTURAL DRAWINGS FOR DUCT SUPPORTS. DUCTWORK TO CONFORM TO SMACNA STANDARD FOR 2" W.C. PRESSURE CLASS. INSTALL NEW 2" GAS PIPING TO NEW AHU ON ROOF. PROVIDE ISOLATION VALVE AND STRAINER AHEAD OF CONNECTION TO AHU FM APPROVED GAS TRAIN. SUPPORT PIPING 10' -0" O.C. (MINIMUM) INSTALL 1" SCH 40 TWO GALV STL SPRINKLER PIPING TO SPRINKLER HEAD IN NEW MU AHU ON ROOF. HORIZONTAL RUNS SHALL HAVE MINIMUM SLOPE OF Y" PER 10 FEET TOWARD DRY VALVE. SEE 1M260A AND M532. ONG NO. KEYPLAN NO SCALE OT_ CHECKED APPROVED MA • CUSSVOT REM O( SYMBOL 566282 -01 RFM10 9 -1 O1 -READ RECEi iiEu C1OVOcT,Ikv ;1 t s: 2 5 mei PERMIT CETEf OME 08.03.06 • a • A 8 KNOW CURE OVEN 120VAC 000 PANT e30m MW HARMS HGN Ill I I I 120V /24VAC CONNI L a�lu • TRUNK SLAVE + - s + - C001 C002 POWER w ON OFF (LEDS)0 0 WDT 0 SLAV 1 ON AUTO OFF 2 OM LOAD OVERRIDE O 1/2 AIP SLO -8LO MICROSMART UNIT CONTROLLER MSC -U 1000 120VAC, 60 Watts, 50/60 Hz, 1 -PHASE DCM01 ADDRESS = SLAVE 01 CONTROLS AHU 84 421EA9B8B Uflfl • 01 4 U 4 1 U U ti f 0— in co cr. sciii 4 4 4 4 4 4 4 4 AA 0 CO 0 0 ■ Put 2/06 8/06 /3 FK B � B a 7 O O L1 O u a c i D f D M (6 02 — 05 M O es 03 04 CONSTRUCTION NOTES 1. EXISTING ROBERTSHAW SLAVE LOCATED AT COL C/3 2. PAINT BOOTH MAU FLAME FAILURE ALARM WILL CONNECT TO MAU CONTROL PANEL TERMINAL STRIP OR FIELD INSTALLED RELAY IN PARALLEL WITH THE ALARM LIGHT. ALARM WILL BE DRY CONTACT. 3. PAINT BOOTH MAU COLCCED FILTER ALARM WILL CONNECT TO MAU CONTROL PANEL TERMINAL STRIP OR FIELD INSTALLED RELAY IN PARALLEL WITH THE ALARM LIGHT. ALARM WILL BE DRY CONTACT 4. BOEING WILL PROGRAM ALARMS. • INCOMING 120VAC HGN III ! 1 I 120V /24VAC �I I TRANSFORMER r CONNI (LEDS)0 0 VDT 0 SLAV POWER ON iiii ON AUTO OFF 8 OFF LOAD OVERRIDE 1 2 NM 0 FUSE 1/2 AMP SLO -BLO MICROSMART UNIT CONTROLLER, MSC -UC 120VAC, 60 Watts, 50/60 Hz, 1 -PHASE DCM01 ADDRESS = SLAVE 02 CONTROLLS AHU 85 4F^A910114 811111111 TRUNK SLAVE + - s +- 4 w ce 0L N r 4 1 CONN2 C001 c002 120V /24VAC 1RANSFORMER iii .-. R! (h IA .O n 0) 0• 0 0 0 CO CO 0 CO 0 CO 0 .-. 4 4 .4 4 4 • 02 M 0 felA irmernewe - 1 D O a U 0 N CI 4 U I- D 0. r O O 0. 1 0 f E M I (T- 02 03 04 05 4 4 4 4 4 « N CI CO >- Q U J I— W 1-1 � 3 z W LL p t� p V) t'4o& ACCEPTABIUIY I11s COIGN MD 5 (1fW = 6 WOWED DEL oluE MUM MINIM 7 480 VAC DISCONNECT • r • MSC -UC -AV CARD TERMINALS A 480 VAC 120VI FUSE HH • i— RA 5.4 FZT OMS SD SD co AHU FAN WIRING DETAIL POLARITY OF TERMINATIONS IS NOT IMPORTANT CUT SHIELD VIRE AND FOIL BACK AND TAPE THE END OF THE VIRE TO PREVENT ACCIDENTAL GROUNDS SUP. & RET. SENSORS WIRING DETAIL TYPICAL TERI0M1TIONS FOR CONTACT MIT TYPE POINTS /0 TYPICAL ACTUATOR WIRING A MELD T GROUND CUT SHIELD VIVRE AND T OL BACK AND TAPE THE END OF THE VIRE TO PREVENT ACCIDENTAL GROUND'S STAR1ER COIL GREY VIRE MIT OR RED BUTT SPLICE CONNECTIONS TO 24VAC TRANSFORMER FURNISHED AND WIRED AT FACTORY ILK RED '0 RIME DEVICE IS POLARITY SENSETIVE, FOLLOW TERNMATIO1 DIAGR*N CURRENT RELAY WIRING DETAIL AHU84 &85DMS BUILDING 9 401 MEOW/CAL LUSTER COL C/3 • SITE OURREIR NERS+OM CM310 B 9-101— 041310 ffiCEivEu CfYfr T1I3c * *:'z fi SEP 2 5 C4 F !NCE:Nrh COMP NO. 8/06 1