Loading...
HomeMy WebLinkAboutPermit M06-220 - BLUE DOGBLUE DOG 530 INDUSTRY DR M06 -220 CITY OF TUI:\'':I; A DEPT OF CO? C: 1U; ;1Y DEV: '_4f i CENT 6300 SCUTH3LN I LR DLID. TUKWILA, WA 93188 Parcel No.: 0223400020 Permit Number: M06 -220 Address: 530 INDUSTRY DR TUKW Issue Date: 10/12/2006 Suite No: Permit Expires On:04/10/2007 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address' BLUE DOG 530 INDUSTRY DR, TUKWILA WA SBP GENERAL PARTNERSHIP Phone: 617 INDUSTRY DR, TUKWILA WA MARK SMELTZER Phone: 425 251 -0356 25500 74 AV S, KENT WA Contractor: Name: PERFORMANCE HEATING Address' 7649 S 180 ST, KENT WA Contractor License No: PERFOHA15ORT Expiration Date: MECHANICAL PERMIT Phone: 425 251 -0356 04/29/2007 DESCRIPTION OF WORK: INSTALL REPLACEMENT 4 -TON PACKAGE HEAT PUMP ROOFTOP UNIT; SAME SIZE AND SAME LOCATION. Value of Mechanical: $8,200.00 Type of Fire Protection: <100K BTU Furnace: >100K BTU 0 Floor Furnace Suspended/Wall /Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial /Industrial 0 doc: IMC- Permit M06 -220 Printed: 10 -12 -2006 Fees Collected: $258.05 International Mechanical Code Edition: 2003 EQUIPMENT TYPE AND QUANTITY 0 Boiler Compressor: 0 -3 HP /100,000 BTU 0 0 3 -15 HP /500,000 BTU 0 0 15 -30 HP /1,000,000 BTU 0 30 -50 HP/1,750,000 BTU 1 50+ HP/1,750,000 BTU 0 0 Fire Damper 0 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment * *continued on next page ** w PERMIT CENTEF 0 0 0 0 0 0 CITY OF TUKWILA DEPT. OF CO`.LMU ?.ITY DEVHOPM3NT 6300 CCUTHCENTER CLVD. TUKWILA, WA 93188 Permit Center Authorized Signature: I hereby certify that I have read and ordinances governing this work will be Permit Number: M06 -220 Issue Date: 10/12/2006 Permit Expires On:04/10/2007 AtAk4 is permit and know the same to be true and correct. All provisions of law and mplied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatin• c= the p- of work. I am authorized to sign and obtain this mechanical permit. Signature: � 1�1 .r Date: t d 1210E Print Name: ( PrAr; C\ �t asS PFPglIT CFINTER Date: 1/1)[ (LIMP This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doe: IMC- Permit M06 -220 Printed: 10-12-2006 DEPT CF 63W c":J11 , .l .i.;, TUKWILA, v!A £ "1183 Parcel No.: 0223400020 Permit Number: M06 -220 Address' 530 INDUSTRY DR TUKW Status: ISSUED Suite No: Applied Date: 10/05/2006 Tenant: BLUE DOG Issue Date: 10/12/2006 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 8: VALIDITY OF PERMIT: The Issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the doc: Conditions M06 -220 Printed: 10 -12 -2006 PERMIT CENTEF PERMIT CONDITIONS CITY OF TtIK`: " I A DEr T. OF CC'.':.'.L ::. i "`; G :'': ' r: • £300 J3. TUKLViLA, VIA 9j 1 63 Building Official from requiring the correction of errors in the construction documents and other data. **continued on next page ** doc: Conditions M06 -220 Printed: 10 -12 -2006 `' PERMIT CENTER (',rfY DEPT. OF CC'.'.':.:i; :.. ( C_. . . NT 6300 E.- UfF{,;,;J: ..;[ J. TUKwitA,WA £Jibd I hereby certify that I have read these conditions and will comply with them governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or regulating construction or the performance of work. - ■��7.• Signature: •••17 9 o: \ \ AL. \7r Print Name: doc: Conditions M06 -220 Printed: 10-12-2006 PERMIT CENTER as outlined. All provisions of law and ordinances cancel the provision of any other work or local laws Date: �c� CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htip://www.ci.tukwila.wa.us Site Address: 530 Industry Drive Newton City Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 0223400010 Suite Number: Floor: Tenant Name: New Tenant: ❑ Yes ❑..No Property Owners Name: Blue Doe Properties Trust Mailing Address: 400 Centre St MA State 02458 Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Mark Smeltzer Mailing Address:25500 74th Ave S E -Mail Address: mark(a�performanceheating.com Company Name: Performance Heating & Air Conditioning Mailing Address: 25500 74th Ave S Contact Person: Mark Smeltzer E -Mail Address: mark&performanceheatinig.com Contractor Registration Number: PERFOHA15ORT Contact Person: E -Mail Address: Contact Person: E -Mail Address: Q: Applications\Pmms- Applications On Linc\3 -2006 - Permit Application :doe Revised: 9 -2006 b0 Day Telephone: Kent, City Fax Number:253- 867 -5775 425 -251 -0356 WA State Kent, City Day Telephone: 425- 251 -0356 Fax Number: 253 867 - 5775 Expiration Date: 4/29/07 WA State State State 98032 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) 98032 Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Zip City Day Telephone: Fax Number: Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <IOOK BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat I 15 -30 HP /I ,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP/1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50 +HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM I Incinerator - Comm /Ind ye MECHANICAL PERMIT INFORMATION — 206 - 431 - 3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Performance Heating and Air Conditioning Mailing Address: 25500 74th Ave S Contact Person: Mark Smeltzer 1 E -Mail Address: mark(performanceheating.com Contractor Registration Number:PERFOHA150RT Valuation of Mechanical work (contractor's bid price): $ 8,200 Scope of Work (please provide detailed information): Install replacement 4 ton package heat pump rooftop unit, same size, same location. Use: Residential: New ....0 Replacement .... ❑ Commercial: New .... ❑ Replacement ....Er Fuel Tyne: Electric ❑ Gas ....0 Other: R -22 Indicate type of mechanical work being installed and the quantity below: Kent WA 98032 City State Zip Day Telephone: 425- 2581 -0356 Fax Number: 253- 867 -5775 Expiration Date: 4/29/07 Q pplicationsLLorms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bit Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHOB(ZEDAGEN Signature: Print Name: Mark Smeltzer Mailing Address: 25500 74th Ave S I Date Application Accepted IOlosl Q:UpplicationstFonns- Applications On LincU -2006 - Permit Applicationdoc Revised: 9 -2006 bb Date Application Expires Day Telephone: Kent City Date: /a-9 -oA 425- 251 -0356 WA State Staff Initials: 98032 Zip Page 6 of 6 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223400020 Permit Number: M06 -220 Address' 530 INDUSTRY DR TUKW Status: PENDING Suite No: Applied Date: 10/05/2006 Applicant: CITY OF TUKWILA FIRE STATION #52 Issue Date: Receipt No.: R06 -01575 Payment Amount: 258.05 Initials: JEM Payment Date: 10/05/2006 01:55 PM User ID: 1165 Balance: $0.00 Payee: PERFORMANCE HEATING & AIR CONDITIONING, INC. TRANSACTION LIST: Type Method Description Amount RECEIPT Payment Check 50101 258.05 ACCOUNT ITEM LIST: Description Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES Account Code 000/322.100 212.44 000/345.830 45.61 Total: 258.05 0444 10/05 9716 TOTAL 258.05 doc: Receipt Printed: 10 -05 -2006 Project: n / ' � {, . Type of-Inspection: ^�../ �// Address: /� /✓r.G Date Called: 7 1(. /i�/i .5 C) Specia Instructions: —Date Wanted: J—S-4 t Reques[e Jett 0/ { Phone No V24 _LS/ -n7 .5"4. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: (206)431 -3 Inspector: 'Date: S` El Corrections required prior to approval. ri $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Project: , � / v�� lb Type of Inspection: ,' ', ,c ate,, i, Address: Date Called: sio Special Instructions: /i_ a /hr J 474egefi( Date Wanted: �/� ,��/ 12-- !/� / -e ci+A' p.m. Requester: Phone N 7. €6-557- sf] CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. C Corrections required prior to approval. INSPECTION NO. INSPECTION RECORD Retain a copy with permit (2061431 -367 COMMENTS: AL i. / S58. % INSPECTION F ' 7 EQUIR r . Prior to inspection, fee must be pald at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: BTL ENGINEERING Structural Calculations October 5, 2006 MIRES 0943.08 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Fax: (425) 821 -2120 for as- M echanidfl--t • REIT 560 Unit Support REVIEWED FOR CODE COMPLIANCE p ono MW C0 OCT 1 2 2006 ktAA City Of Tukwila BUILDING DIVISION aE CITY of TUKWtA OCT 0 5 2006 PERMIT CENTER MO(r2W BTL ENGIN ERRING 17924 —140* Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Fax: (425) 821 -2120 Calculations BTL ENGINEERING 17924 — 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Fax: (425) 821 -2120 Gravity Support BTL ENGINEERING eAPACI t( 2,41,2 z.i. O. +I '1;'o 01- p- 92‘? Irra.41) /is _A— „tt-4-04 \e1/41k nook? • 1./C /edo 7 s, z,_61 4.1- ( goa r/ '04 • AI 710' )7& I g • I? T s I, to 1_1_ 3-1-- E 4/ 4 , e .-- O.dqq it? k I k _L. l o ,rik - Sg-.53. an /k I LI, ( l eIrsi' Ok. Rola pi Project: 4L) 51/ 0 Project Number: Client Designed By - FP Scale: 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072-4315 Phone: 425-814-8448 Fax: 425-821-2120 Datt ti-3 Page: BTL ENGINEERING 17924 — 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Fax: (425) 821 -2120 Seismic Support Brit E NGINEERIN C Project Name: REIT 560 Mech. Unit Project Number: 06- 199 -02 Criteria Seimic Design Method: Occupancy Category: Site Class: Seismic Use Group: I lE = 1.00 1 = 1.00 / = 1.00 S s = = IBC IBC 2003 /ASCE 7 -02 11- Other Structures D (Seismic Factor) (Snow Factor) (Wind Factor) Revision Date: F. = 1.00 ASCE Table 9.4.1.2.4a F = 1.52 ASCE Table 9.41.2.46 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: 425- 814 -8448 Fax: 425- 821 -2120 10/5/2006 IBC Table 1604.5 ASCE Table 9.4.1.2 Date: 10/5/2006 S - Page: 6-111 E NGI NEERIN C Project Name: REIT 560 Mech. Unit Project Number: 06- 199 -02 Design Base Shear Sus = FaSs = 1.41 Sos = 3 S MS = 0.94 SM1 =F,S1 = 0.73 Sol= %SM1 = 0.49 Revision Date: 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: 425 -814 -8448 Fax: 425- 821 -2120 10/5/2006 Date: 10/5/2006 S z Page: lti 2002 Lat/Lon Lookup Output! 1 of1 USGS science lora changing world LOCATION 47.454206 Lat. - 122.248475 Long. The interpolated Probabilistic ground motion values, in %g, at the requested point are: 10 %PE in 50 yr 2 %PE in 50 yr PGA 32.65 62.51 0.2 sec SA 71.89 141.28 1.0 sec SA 23.64 48.31 SEISMIC HAZARD: Hazard by Lat/Lon, 2002 http: //e pint. cr. usg s. gov /e q- men /cgi- bin/find -11- 2002- interp -06. cg i S-3 BTL ENGINEERING 5e7siutc e re 0,q (a?) (1/25)6.0( I 4 2 1 ) F P --- ' OvearvAra Lio Z .5 S QM 1 1‘. leo V 3,431 uP/ ipr 4440 ( ,D54 0.10 (4,J,) ( 1 4 " z = 4sps) (Tp)(t40 0 IA) - 2_02 2 ( + Inv( s4) /cogs FS T io 5,8 131- 41/4 D,3 (0,54 zoz 2.2. 5 / - 0 6(0 4 q)( 1 1.0)( w f ok W e s . - 491. C 104.0 .1•S (imy) 0,2.82_ (it) 33 k` (FPKA. (tt.>) Project: an- C40D Atm, Ow Project Number: Designed By: lac Client Scale. 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072-4315 Phone: 425-814-8448 Fax: 425-821-2120 Date. Page: BTL ENGINEERING U yr AN et-taake.ii.; cr.) V' tk s p5z. 1 57rArrs Ptraz, SiPt 2-ot. 41 IL SCakv tit Project: Ile-) 9E Mn 4 UM-r Project Number: Client Designed By: IN Date. Scale: 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072-4315 Phone: 425-814-8448 Fax: 425-821-2120 BTL ENGINEERING 17924 — 140 Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Fax: (425) 821 -2120 Details INSTALLATION / SERVICE CLEARANCE APPROX. CORNER WTS LBS. TOTAL MODEL WEIGHT W1 W2 W3 W4 LBS. WCH048F 128 128 97 97 447 WCHO6OF 115 115 114 114 457 INSTALLATION / SERVICE CLEARANCE BACK 48.0" LEFT SIDE 24.0" RIGHT SIDE TOP 36.0' • INANE / u3 a SYRP1' .O*CR COURT WCH048 -060F OUTLINE DRAWING NOTE: ALL DIMENSIONS ARE IN MM (INCHES) I R4 U/U n. Dimensions Y , } � 9/1 }1 NOTE 3/4" SUPPORT RAILS LOCATED UNDERNEATH BASE OF MIT 18 34,3 . I3/ I '4431! SZ3LII 1 A O PVC PIPE ) /'1 / MT a 0 / °LSS . xu ,,-20202 113[11 COIL 114.63 COVNECTION3 1 33/321 UNIT POWER 314103 ONIPOL WIRING N 4:001; te..(--; 4- Av.., It. tz" r.{h)1 k.E 1 CLEARANCE 3•" (940 MM) 1 253 1.0.4 • ' 9ASFfN gTU 1zcolt Lc:jigs 5 G r ( * 150.2ttA.3 , Tit C ( C0e1--teg. 5 CLEARANCE a HORIZONTAL FLOW - 18" (457 MM) DOWNFLOW 36" (914 MM) ACTIVITY NUMBER: M06 -220 DATE: 10 -05 -06 PROJECT NAME: BLUE DOG SITE ADDRESS: 530 INDUSTRY DR X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Buifdfhk Ditl n Public Works ❑ Complete Comments: Approved ❑ Notation: APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28.02 PERMIT COORO7 COPY PLAN REVIEW /ROUTING SLIP Fire venn o I �fr Structural DETERMINATIQN OF COMPLETENESS: (Tues., Thurs.) Incomplete Planning Division ❑ Permit Coordinator ❑ DUE DATE: 10-10-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Approved with Conditions ❑ No further Review Required ❑ DATE: DUE DATE: 11-07 -06 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License PERFOHA 1 5ORT Licensee Name PERFORMANCE HEATING & A/C INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600601386 Ind. Ins. Account Id 49459900 Business Type CORPORATION Address 1 7649 S 180TH Address 2 City KENT County KING State WA Zip 98032 Phone 4252510356 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/30/1985 Expiration Date 4/29/2007 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date GOWIN, RICHARD L 01/01/1980 GOWIN, CONSTANCE F 01/01/1980 Look Up a Contractor, Electririan or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must mamtain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond tt9 Bond Company Name DEVELOPERS SURETY & INDEM CO Bond Account Number 853803C Effective Date 04/28/2002 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount $ 12,000.00 Received Date 04/23/2002 https: // fortress. wa. gov /lni/bbip/ printer .aspx?License= PERFOHA15ORT 10/12/2006 HVAC EQUIPMENT SCHEDULE TAG MANUFACTURER DESCRIPTION MODEL NO. NOMINAL TONS CAPACITY .STUN - SE&P� HSPF CHI E.S.P. FAN HP uMrarcTRrca. HEATER ELECTRICAL SOUND dB(A) wem,► (mil ���� REMARKS HEATING COOLING VOLTS PHASE MCA ApCP VOLTS PH�{SE MCA MOCP Rill iR/NE ROOFTOP PAf.KAGE ;VAT R1hP 4FC.G3048A3 4D *woo 47500 135/12A 8.0 1600 Ob IA 209 340 23.6 35.0 209 31 ZbA 30A 84 449 400 N7N ECONOMIZER t SMOKE DEi6GT0 t INDUSTRY DRIVE SCALE: 118' =1'-O' a NORTMI SOU11-1 R 1 1 1 1 1 1 1 1 1 1 1 1 i i 1 II 1 1 i 1 1 1 PARTIAL ROOF HVAC PLAN 1 r 1 AREA 1 OF WORK 1 11111 1 1111111111111 t ! s / 1 ! i 1 1 1 1 1 i 1 1 111 1 III11 1 1 1 1 1 1 1 1 ! I I 1 1 1 1 t 1 / 1 ! 1 111111111E 111 11 1 i 1 1 1 i 1 1 r r 1 t ! r 1 1 1111111 11 11 i r 1 1 / t 1 1 1 i 1 ! 1 ! ! I i 1 - - I s It s - ! 1 I t - HrHri- / . 1 1 . I11 1 1111111 1 11111E1 1111111111111111111 1 I t ! 1 ! ! 1 1 ! 1 ! i ! ! 1 I 1 1 ! ! r 1 1 1 t �I11 11111111111111111111111111111111111. 1 r t 1 ! t 1 ! I 1 I 1 t 1 i ! ! ! 1 ! I. ! ! t 11111111111111 I11111111111111111111111 JJ_ LiJ_ L1J_ L1J_L iJ_ LiJ_ L1J_LiJ_LiJ_LiJ_L1J_L1J_Lii___� 1 1 I I 1 RTU -I: 4.0 d1(A) PROVIDE 4 INSTALL lUl 4-T014 ROOFTOP PACKAGE FEAT PUMP TO REPLACE EXISTING FAILED 4-TON ROOFTOP PACKAGE TEAT PUMP NEW UNIT TO BE INSTALLED IN SANE LOCATION AS EXISTING. FASTEN UNIT TO EXISTING ROOF SLEEPERS. SEE ATTACHED STRUCTURAL AND SEISMIC CALCULATIONS FOR RECOMMENDED FASTENING METHODS. CON 1C NEW UNIT TO EXISTING LINE VOLTAGE 4 LOW VOLTAGE UTILITIES. CONNECT NEN UNIT TO EXISTING SUPPLY 4 RETURN DUCTWORK. • ■ MOM e,a_^. ges shall be mods to the mops - - .: l out peior approve of Dtyes: t. 0 1NGLWES ECONOMIZER 1 BARO TRIG REUEF DAMPER • REVIEWED FOR 1 CODE COMPLIANCE anonym A OCT T 2206 r j ,--0 QtyOf villa BUILDING QMSTn SEPARATE PERMIT REQUIRED FOR; e 0 Piloting 0GasPOlg City of Tt k': 'a BUILDING DIVISION VICINITY MAP NO SCALE KIN& COUNTY PARCEL NO.: 0223400010 LEGA DESCRIPTION: 1 -2 4 3 ANDOVER INDUSTRIAL PARK #5 LESS UP RR OPER R/W • SCOPE OE WORK:: PROVIDE 4 INSTALL NEW 4-TON ROOFTOP PACKAGE FEAT RH' TO REPLACE EXISTING FAILED 4-TON ROOFTOP PACKAGE TEAT PUNS'. NEW UNIT TO BE INSTALLED IN SANE LOCATION AS EXISTING. FASTEN UNIT TO FXUST1N6 ROOF SLEE'&5. SEE ATTACHED STRUCTURAL AID SEISMIG CALCULATIONS FOR REGON4IENDEP FASTENING METHODS. CONNECT IAN UNIT TO EXISTING LINE VOLTAGE 4 LOW VOLTAGE UTILITIES. COt1€ T NEN UNIT TO EXISTING SUPPLY t RETURN DUCGTWORI:. CODE NOTES:: I) SEAL DUCTS PER W.SLG. SECTION 1414.1. 2) INSULATE DUCTWORK PER W.S.E.G. TABLE 14-6. 3) PROVIDE ECONOMIZER REQUIRED PER W S.EG. SECTION 1433. 4) NO SMOKE DETECTOR REWIRED PER I.M.C. SECTION 60621. 5) A 110V CONVENIENGE OUTLET SHALL BE WITHIN 25 -0' OF OUTDOOR EQUIPMENT PER I.M.C. SECTION 306.4.1 6) ROOF ACCESS TO EGTAPNENT TO COMPLY WITH I.M.G. SECTION 306.5. •1! ... 6 rehaff epreovai is subject b anus and ambit,* Approval azz-edion the 1f�rG.'1 t:` u does fipt �j�i at a�prar� r.__ �� a°° Z ., , �a�".�r�ar�. S aomasiedant FILE BUILDING NEON • FISCEIVED f; 5 2006 DATE: 1012106 DRAWN: SPS ENGR: SPS APPVD: JOB NUMBER: 069lann -06 M 1 g i i 1 viii 1 i 4I 1 4 • lit Ira ' t i r w SHEET 1 OF CO CO 1 •