Loading...
HomeMy WebLinkAboutPermit M06-224 - MAJESTIC BUILDERSMAJESTIC BUILDERS 4028 S 126 ST M06 -224 Parcel No.: 7945200045 Address: Suite No: Tenant: Name: Address: Owner: Name: .Address: 4028 $128 ST TUA'W Contractor: Name: Address: Contractor License No: City r.sf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MAJESTIC BUILDERS 4028 S 126 ST , TUKWILA WA Contact Person: Name: JONATHAN M.HARKOVICH Address: 1201 MONSTER RD SW, STE 320 , RENTON WA DESCRIPTION 01' WORK: MECHANICAL FOR NEW 2536 SF SFR DAVIS & ROBINSON INC 1201 MONSTER RD S , RENTON WA Value of Mechanical: $4,200.00 Fees Collected: Type of Fire Protection: NONE International Mechanical Code Edition: 2003 Furnace: <100 %BTU >1001C BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duc Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY 1 0 0 0 1 0 0 0 0 4 1 1 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: Phone: Expiration Date: M06 -224 07/12/2007 01/08/2008 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU 0 30-50 HP /1,750,000 BTU 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 1 Wood/Gas Stove 1 Water Heater 1 Emergency Generator 0 Other Mechanical Equipment 0 $211.95 doc: IMC -10/06 M06 -224 Printed: 07 -12 -2007 Permit Center Authorized Signature: sws City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: htip: / /www.ci.tukwila.wa.us Permit Number: M06 -224 Issue Date: 07/12/2007 Permit Expires On: 01/08/2008 Date: 7 U_ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or e performance of work. I : • authorized to sign and obtain this mechanical permit. Signature: �e: I.jo isai ems. ==. ./ .:. GAIL / 7 5/ /�'- 6 /L/�F�� Date: ‘27/107 Print : SV ,w. /��a1�i i This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10 /06 M06 -224 Printed: 07-12-2007 Parcel No.: 7945200045 Address: Suite No: Tenant: 4028 S 126 ST TUKW MAJESTIC BUILDERS 1: ** *BUILDING DEPARTMENT CONDITIONS *** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 -3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 10: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 11: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor - fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 12: AB plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 -3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 M06 -224 ISSUED 10/06/2006 07/12/2007 M06 -224 Printed: 07 -12 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 7 7 M06 -224 Printed: 07 -12 -2007 Company Name: Mailing Address: E-Mail Address: CITY OF TUKWILA L) Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print" Saud/ /26a 714e-e /LA wA Site Address:_ Tenant Name: Property Owners Name: 414TE577L gd/Loce S King Co Assessor's Tax No.: 794520 -006 Suite Number: Floor: New Tenant: 0 .... Yes 0 ..No Mailing Address: /2o/ /7wszrt ,4090 SA/- 514/manlj0 ArnovMJ k/4 57 State Tip City Name: JiNa$31/ AV orne-tw1C.4' Day Telephone: (2 53) 3 /S 3/70 Mailing Address: /2a/ "wing_ ,2o4j) S4 32o RQ'ivrzN u// OYeri / cit state Tip E-Mail Address: via Metir-/L &ate' /S/ • CC.W Fax Number: 025) 226— 9227 L AL r gIN RAS - ?R c 1<TQN ptira Irifornfatfpi2}�gt �FYec�ieni'�s (p 4i*.%). umb ng, gd 6aal'iping'(`Pg Company Name: "Voirj5 1 /G € &/LDE,cs Mailing Address: /10/ own 57Z�,t ,¢OA/) Slt/ - so "rE Contact Person: /17th /Qd&'A/Sd / E-Mail Address: ' A/ b% -_he» Beers, //el Contractor Registration Number: aa 4t tSE*75y//1E 330 ,eE' I tuft 9trOS7 City Day Telephone: l -V25) 255 Fax Number: 6925. 2 Expiration Date: 0 7 / ?S 67 Company Name: Ca#OF /PE/77»L ,Ocs /64V Mailing Address: /OZ Sat TH Z6a cr. 77LO//14- !.t/A City t State Zip Contact Person: Day Telephone: (2'53) ZSi/-3 /70 E-Mail Address: Fax Number. ( 543 cfrz n tonsil fl 9Z VE5 /6W /02 Sean/ Z Contact Person: ,%*€,,t ,e. 411y,6,t5 Q:Wpienie.grom a- App0eatio0. On Linev•2006 • Pe,ma Appticadoe.doe Revised: 4•2006 eA 7X Avg froYZ City State Zip Day Telephone: (2S3) 28'V 3/74 Fax Number: (•3) fl'/ l3 Page 1 of 6 / Valuation of Project (contractor's bid price): $ / GlC'CI Existing Building Valuation: $ Scope of Work (please provide detailed information): r4 /V4V S/Nlre E -GAJJr /Gr fl.0t/V E 4 Ge-ieb & fa.2- laNDJF?/ON Die wfvq ten9t -S, ,4r co 'Dn. Will there be new rack storage? ❑ ..Yes Di.. No (If yes, a separate permit and plan submittal will be required) All:��ilditlg A 1 Twegso " , .- Detached G ag: Attached.Caipott petached Carport •, Covered. Deck ; Uncovered Deck F isting me Adilitaotl lo" Existing . /O /156 '/6Z �yo V -8 Q -3 i 1 PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): de 95 Floor area of principal dwelling: Z534 Floor area for accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Z Compact: Handicap: Will there be a change in use? a ....Yes ❑ ..No If "yes ", explain: VkAvr L✓or Ntaa/ gf9/J,sig FIRE PROTECTION/HAZARDOUS MATERIALS: ❑.. Sprinklers ❑ ..Automatic Fire Alarm Egt None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑..Yes No Ij "yes attach list of materials and storage locations on a separate 8 -1/2 s 11 paper indicating quantities and Material ety Data Sheets. SEPTIC SYSTEM: ❑ On - site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. QiAPPiicaimuWams-Appli,atiau On Line\ -2006 - Pamir AppIiratbn.doc Roland: 4-2006 M Page 2 of 6 Scope of Work (please provide detailed information): /¢" NSW 5 /4I4-E -F f /4/ 4 S'ocwGE /A//1z/ /NW /O c/v e-- b,C# w6- yte ,& v )tint N .bacEa4V, wit/45, AND .� Dom. Water District ❑ ...Tukwila Z... Water District 8125 0... Water Availability Provided Sewer District ❑...Tukwila ❑...Sewer Use Certificate Please refer to Public Works Bulletin #I for fees and estimate sheet. Submitted with Application (mark boxes which apply): ❑...Civil Plans (Maximum Paper Size -22 "x ") ❑...Technical Information Report (Storm Drainage) ❑...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that sooty): ❑...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Rightof - way Use - No Disturbance ❑ ...Construction /Excavation/Fill - Right-of-way Non Right-of-way ❑...Total Cut 0 cubic yards ❑ ...Total Fill 0 cubic yards �... ValVue 0... Sewer Availability Provided ❑...Sanitary Side Sewer ❑ ❑...Cap or Remove Utilities ❑ ❑ ...Frontage Improvements ❑ ❑ ...Traffic Control ❑ . ❑...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑...Permanent Water Meter Size... 14 " O - Temporary Water Meter Size.. ❑...Water Only Meter Size ® ... Sewer Main Extension Public Private pa ...Water Main Extension Public Private FINANCE INFORMATION Fire Line Size at Property Line Water ®:..Sewer Monthly Service Billing tot Name: /lIATE5 PC /3'0/4 AE„25 Mailing Address: /20/ /7T0/t/SPEQ "ego Water Meter Rehm Name: S e M Atvir Mailing Address: Number of Public Fire Hydrant(s) ❑...Sewa Treatment Day Telephone: (7 2 35 G6e: / Stu 544/7F-.ie 330 RE/vr»N WA 90057 State Zip City Day Telephone: City State tip OMInnicano sWo.ID - *ppilcRplM On t.ineV 4006 • PR111a Application.dOc Reviled: 44106 66 Cali before you Dig: 1- 800 - 424-5555 . Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line ❑ .. Highline ❑ ...Renton ❑..Renton ❑...Seattle ❑ .. Approved Septic Plans Provided ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use - Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑... Traffic Impact Analysis ❑ ... Hold Harmless - (SAO) 0... Hold Harmless - (ROW) ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑...Deduct Water Meter Size Page 3 of 6 UuitType:: Qty" Unit Type: Qty ; UfitType: , Qty Boiler /Compressor: Qty Fumace<100K BTU / 1 Air Handling Unit >10,000 CFM Fire Damper - 0-3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3A5 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct / Water Heater / 50+ HP/1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment MECHANICAL CONTRACTOR INFORMATION Company Name: re Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Valuation of Project (contractor's bid price): $ s51 UO Scope of Work (please provide detailed information): %e 4*y .Art/O /4 99 SAC mgmfrvet. 'No pew" woLC Use: Residential: New ....0 Replacement .... ❑ Commercial: New .... ❑ Replacement .... ❑ Fuel Type: Electric ❑ Gas ....a Other: Indicate type of mechanical work being installed and the quantity below: QMppllattoatpame- Appliia6au On LIneU- 2006 - Permit Appliation.da Rased: 4 -2006 bb Expiration Date: Page y Fixture T'ype;. Qty Fixture Type; Qty Fixture Type: ' Qty Fixture Type: Qty Bathtub or combination bath/shower 2. Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets 2 Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks q Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory 2 ..J Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent I Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Additional medical gas inlets/outlets — six or more Company Name: Mailing Address: PLUMBING AND GAS PIPING CONTRACTOR INFORMATION 780 Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): S Vet, Scope of Work (please provide detailed information): la/Pax 1.460 ,'tflnotG friamear F .64VD G�5 ,o /p /N6 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q UppliutionVom.- Appllaiom Q, L166%34006 - Permit Appliaiondoc Raised: 42006 bh Page 5 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of' time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O ,, ER ' A 0 O t Signature: Print Name:. Ad2,'It c/✓ Day Telephone: (9Z5) 235 - 66cV Mailing Address: /ZO/ .06 01 QLI¢D 574/-514/TE,nego ,€SMVN w,4 9$oC7 City grate Zip Date Application Expires: V l de t I Date Application Accepted: I (t Q:Npplicalimuwame- Applications On LineV -2006- Permit Applicadon.doc Revised: 4 -2006 bb Date: ` It. y /Ze„► ( Staff Initials: Page 6 of 6 Receipt No.: R07 -01377 Payee: MAJESTIC BUILDERS ACCOUNT ITEM LIST: Description MECHANICAL - RES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 7945200045 Permit Number: MO6 -224 Address: 4028 5 126 ST TURW Status: APPROVED Suite No: Applied Date: 10/06/2006 Applicant: MAJESTIC BUILDERS Issue Date: Initials: WER Payment Date: 07/12/2007 02:49 PM User ID: 1655 Balance: 50.00 TRANSACTION LIST: Type Method Description Amount Payment Check 7212 175.56 Account Code Current Pmts 000/322.100 175.56 Total: $175.56 Payment Amount: 5175.56 0271 07/13 9710 TOTAL 4346.99 doc: Receipt -06 Printed: 07 -12 -2007 Copy Reprinted . on ID-06 -2006 AL 15:26:27 10/06/2006 RECEIPT NOV R06 =01589 Initials: JEM User ID: 1165 Payee: MAJESTIC BUILDERS SET ID: S000000581 SET TRANSACTIONS: Set Member . ..:' Sr06P375 ""P006 -178 TOTAL- TRANSACTION LIST: Type Method Description Payment ACCOUNT ITEM LIST- Description Amount .7,1.737.0:143 36:39 69.00 2,075.87 Check 6200 .rBLAN -.- : RES PW EASE APPLICATION FEE PW•PLAN REVIEW :City ofTt iti ila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 ,P.hoae: 4313670 " Tax:°206:431-3665 SET RECEIPT SET NAME: Tmp set/Initialized Activities M00/345-830 DOD/322.100 000/345.830 TOTAL: Payment Date: 10/06/2006 Total Payment 2,075.87 Amount 2,075.87 TOTAL: . ...:;2;075.87 Account Code Current Pmts. 1,500.87 250.00 225.00 2,875.87 Steven M. Mutter. Mavor Steve Lancaster, Director 0571 10/10 9710 TOTAL 2075.87 COMMENT 3k ' ' (1 I9-t r e_A -1, t7 ^{c%" MP 1 N NswetA l .ref Af f PJrl r 1-ti i ' t.tlkiiA Project: r Type of Inspection: , C-{ MA3i e - t Su: ( kir PrOA - I MCA MAt Addre i a Z S 126 �.._- Date Called: a.m. I Special Instructions: `� � Date Wanted: / / �� O � r ) 15:3(0 O J .0 Requester: I ' U /`` Pho ne No: 7S 3-26' 94S7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION '` 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431.347 Approved per applicable codes. Inspec :1 4486-Z?-4 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must b paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: (Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION '` 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431.347 Approved per applicable codes. Inspec :1 4486-Z?-4 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must b paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: (Date: Proect: A.'F Type AInspection: (/ Date Called: v V Add L I 6 2 ° 5 )7 ( Special Instructions: Date Wanted: 1 v / �J7 p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSP ` ION NO. PERMIT CI T OF TUKWILA BUILDING DIVISION ft! 6300 outhcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 6 0 *pproved per applicable codes. COMMENTS:_, ' / 3ti / (r7 spector�: REINSPECTION FEE REQUIRE . Prior o inspection. fee must be aid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: (Date: El Corrections required prior to approval. Proje t: f1.Jc-'ST( Type of I pection: /( 9h iv Address. 5 / 2 6 . 5 1 Date Called: Special Instructions: Date Wanteed: _c Cal p.m. Requester: Phone No: - 2 66 6V 5 7 INSPECTION RECORD R etain a copy with permit INSPECTION NO. I CITY OF TUKWILA BUILDING DIVISION J 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -W6 Approved per applicable codes. COMMENTS: In pector: A.wi47 $q REINSPECTION FEE REQUIRED. rior o inspection. fee must be at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: I /3a /0 7 'Date: .. �.,_ --3. _..,.... ) 4 - MO6- 2y PERMIT NO. Corrections required prior to approval. Project: / / &! t°sf r Type 0 Inspection:. ..A .evSt /7 \/ Address: V Date Called: Special Instructions: Date Wanted: /6 %d /c l> ( m �p Requester: Phone No: "7 - 53 — z� _ ( " 5 7 INSPECTION RECORD Retain a copy with permit 4 27 / PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION '1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431.37 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Ass.r I. - -- $58.00 REIN ~ FEE ' • IR r . Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 00. Cal the schedule reinspection. 'Receipt No.: 'Date: COMMENTS: 6) 4 ei i 61-- -X - 4/1/ -. /.4711 (/c "4 /C; //44.1 ,s 5-i A. n r/r/ /(II 4- , ° 1 77 - 1-1- Gu j A/ ✓t / 4/ %9 7 - ( ) e , /1A - /- Date Called: Special Instructions: Date Wanted: / /Z ) /c'7 a.m. Project: /7 i> �‘5T / et Type of Inspection: ., Pe:M /t f / - / U \ Address: Z/(2 5 / ?G 5-1 Date Called: Special Instructions: Date Wanted: / /Z ) /c'7 a.m. Requester: Phone 2.)..3 Z67 5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431.36j0 Approved per applicable codes. Corrections required prior to approval. $58.00 REINSPECTION FEE REQUIRED. Pnd o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: .. itatlisiarrit■ ti Projec ' 2/Q / .v /(3 Type o ion: /N Adirgsy:2 S / G 7 e ST Date Called: Special Instructions: Date Wanted/ jr- Z z �l] 01z7 7 P.m. Requester: Phone No: 2S3 - 6 957 9 -1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 COMMENTS: es dlin f 7) ,ern D 1/i aKtyse° n' JE7'C hspect Approved per applicable codes. 048.00 REINSPECTIOI(1 FEE REQUIfIED. Prior o inspection. fee must be aid at 6300 Southcenter Blvd.. Suite 100. Cal the schedule reinspection. 'Receipt No.: 'Date: c orrections required prior to approval. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Permit Center/Building Division: 206 -431 -3670 Public Works Department: 206-433-0179 Planning Division: 206 -431 -3670 Project Name: �q ft N Site Address: O„ L . SOa7W /716 raier,4,4Mht/f r�++�ui r ' / WASHINGTON STATE ENERGY CODE HEATING DESIGN (select A, B or C below): c. A. • System Analysis - W.S.E.C. Chapter 4 (submit documentation) B. • Component Performance Approach - W.S.E.C. Chapter 5 (submit documentation) C. Prescriptive Option - W.S.E.C. Chapter 6 (for prescriptive, complete the following calculation): 25 3,;, 1. 2. 3. A. ❑ B. RESIDENTIAL HEATING AND VENTILATION COMPLIANCE FORM (Complete Sections I and II for Group R Occupancies 4 Stories or Less) 1I. WASHINGTON STATE V /11, 4Tf5 0.a/torte Pax copy House Square Footage (heated space): 2 Heating System Installed, (check system type be ❑ Electric Resistance ❑ Electric (forced air) El Other Fuels eat pump) Ventilation by Performance or Design Method - .S.V.I.A.Q. Section 302 (submit documentation). Prescriptive Ventilation Options - W.S.V.I.A.Q. Section 303 (select one of the following): 1. ®' Ventilation using Exhaust Fans (Section 303.4.1.) ❑ Exception for outdoor air inlets - Forced air heating system w /interior doors undercut 15' 2. ❑ Ventilation integrated with Forced Air System (Section 303.4.2.) 3. ❑ Ventilation using Supply Fan (Section 303.4.3.) 4. ❑ Ventilation using Heat Recovery System (Section 303.4.4.) ❑ Prescriptive Minimum/Maximum Outdoor Air Calculation specified in Table 3 -2 (see reverse side of form). 1. EffsdS:. 7/1102 4ppiic.tion•IM.1.p text ventilation .y.lwn -tam n4 (7 -2002) MECHANICAL PERMIT APPLICATION NO.: BUILDING PERMIT APPLICATION NO.: l/lx NA X 20 BTU/h • • 2••C P fA Ap VED 0- 11 CI" 4S' ' oi Tuk la • • si A �3t jt r • House Square Footage: 2656. 2. House Number of Bedrooms: 6 3. Required Outdoor Air Table 3 -2: Minimum - /ZO cfm Maximum - 1,0 cfm gap -2 4 of Heatiog Output RECEVED CITYOFTUKWILP OCl 06 ?OR PERMITCENTER r B below): TABLE 3 -2 VENTILATION RATES FOR ALL GROUP R OCCUPANCIES FOUR STORIES OR LESS Minimum and Maximum Ventilation Rates: Cubic Feet Per Minute (CFM) Floor Area k2 <500 1001 -1500 ZIMPI 2001 -2500 3001 -3500 4001 -5000 e lf itr'R1J ttxidi'. 6001 -7000 �s pl� 8001 -9000 prei) Bedrooms 2 or Tess Min 50 60 70 80 95 115 135 Max 75 90 105 20 143 173 203 3 Min 65 75 85 95 110 130 150 UFO a` Max 98 113 128 143 165 195 225 P - 4 Min 80 90 100 110 145 165 Max 120 TFYts 135 AKKIRTIT 150 rITIZTEA 165 218 248 5 Min 95 105 115 125 160 180 Max 143 158 173 188 240 270 6 Min 110 120 130 140 175 195 Max 165 180 195 210 263 293 7 Min 125 135 ra: 145 155 190 210 n his rrligt ai Max 1 203 218 233 4'21 285 315 8 Min 140 150 160 170 Max 210 225 240 255 205 225 308 338 For residences that exceed 8 bedrooms, Increase the minimum requirement listed for 8 bedrooms by an additional 15 CFM per bedroom. The maximum CFM is equal to 1.5 times the minimum. 1. For each additional elbow subtract 10 feet from length. 2. Flex ducts of this diameter are not permitted with fans of this size. Effective: 711102 1.PPrceoum0nehq and ventilation system - form b4 (7 -2002) TABLE 3 -3 PRESCRIPTIVE EXHAUST DUCT SIZING Fan Tested CFM 0.25' W.G. 50 50 80 100 125 Minimum Flex Diameter 4 inch lt 6 inch 5 inch tit 5 inch' 6 inch Maximum Length Feet 25 No Limit 15 NA 15 Minimum Smooth Diameter 4 hich 6 Inch z 5 inch 5 Inch 6 Inch Maximum Length Feet 70 No Limit 100 J 50 r14 No Limit Maximum Elbows' 3 3 3 3 June 25, 2007 Jonathan Harkovich 1201 Monster Rd SW, Ste 320 Renton WA 98057 City of Tukwila Department of Community Development Steve Lancaster, Director RE: Request for Permit Application Extension #2 Development Permit Application No. D06 -378 Mechanical Permits Application No. M06 -224 Plumbing/Gas Piping Application No. PG06 -178 Majestic Homes — 4028 S 126 St Dear Mr. Harkovich: This letter is in response to your written request for an extension to Permit Application Nos. D06 -378, M06 -224, and PG06 -178. The Building Official has reviewed your letter and considered your request to extend the above referenced permit applications. The City of Tukwila Building Division will be extending the expiration date of your permit application for an additional 90 days (through October 1, 2007). If you should have any questions, please contact our office at (206) 431 -3670. File: Permit No. D06 -378, M06 -224, & PG06 -178 P:\Pemdt CenteAExtension Leners\Penmt App &ations006 - 378+ Application Extension P2.doc jem • Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206- 431 -3665 dit Davis &Kurth°' Extension Request for M06 -224: I am writing in regards to my current permit application applied for on 10.06.07, and requesting an extension to the 07.03.07 expiration date. There was not just a building permit that was being dealt with on this lot but also a BLA that has just previously recorded. I was also just informed that I have yet another (FOURTH) comment letter coming from Building and Planning. There is a lot of slope and some critical areas that need to be dealt with and it has slowed the process down quite substantially Thank you for giving me this chance to explain my circumstances to the lengthy process that has taken place. I hope to receive the extension. Thank you. Regards, than M. Harkovich 253- 315 -3170 RECENED CITY op m itwiLA JUN 21 2007 PERMIT CENTER cito d • 0,!207 tie Akio;. (A 1201 Monster Rd. SW #320 • Renton, WA 98057 Office: (425) 228 -5959 • Fax: (425) 226 -9227 www.davis- kurth.com 06-04 -2007 JONATHAN M. HARKOVICH 1201 MONSTER RD SW, STE 320 RENTON WA 98057 RE: Permit Application No. M06 -224 4028 S 126 ST TUICW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 10/06/2006 , has not been issued by the City of Tukwila Permit Center. Per the International Building Code and/or the International Mechanical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 07/03/2007 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 07/03/2007. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marshall Pew ' t Technician xc: Pent File No. M06 -224 V City of Tukwila Steven M Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206- 431 -3665 March 14, 2007 Jonathan Harkovich 1201 Monster Rd SW, Ste 320 Renton WA 98057 RE: Request for Permit Application Extension Development Permit Application No. D06 -378 Mechanical Permits Application No. M06 -224 Plumbing/Gas Piping Application No. PG06 -178 Majestic Homes — 4028 S 126 St Dear Mr. Harkovich: This letter is in response to your written request for an extension to Permit Application Nos. D06 -378, M06 -224, and PG06 -178. The Building Official has reviewed your letter and considered your request to extend the above referenced permit applications. The City of Tukwila Building Division will be extending the expiration date of your permit application for an additional 90 days (through July 3, 2007). If you should have any questions, please contact our office at (206) 431 -3670. City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director File: Permit No. D06 -378, M06 -224, & PG06 -178 P:Vennifet,Extension Lettera\Perit Applications \D06-378 +Application Extension.doc jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206-431-3665 March 8, 2007 To Whom It May Concern: I was writing in regards to Application # D06 -378. This is for Jennifer Marshall. I would like to have an extension granted for this file due to extensive comment letters sent by the Planners, Public Works, and building department. Jill Mosqueda in Public Works, who no longer works for your Jurisdiction, had me get a signed WET- STAMPED site plan that I found out was not necessary. This slowed down my process of issuance of the building permit. Please consider this statement and grant me an extension. I love working with the City of Tukwila, especially Jennifer. She is consistently nice, kind and professional every time I deal with her. This is much appreciated. Sincerely, athan M. Harkovich 4 ; 917378 Moe - 2z4 417 49 -1 ors , - T t Q3 -13 -07 'e t0101- cee 0 : 1 1 1 0 4 51- kteeiv QFir' atA MAR 08 20 " 07 rE ,uir cevrem 03 -01 -2007 JONATHAN M. HARKOVICH 1201 MONSTER RD SW, STE 320 RENTON WA 98057 RE: Permit Application No. M06 -224 4028 S 126 ST TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 10/06/2006 , has not been issued by the City of Tukwila Permit Center. Per the International Building Code and/or the International Mechanical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your pennit application expires on 04/04/2007 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 04/04/2007. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event you do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, XC: Permit File No. M06-224 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 DEPARTMENTS: Bwl g Division ICJ Public Works Complete �t Comments: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 �` PERMIT COORD COPY" PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M06 -224 PROJECT NAME: MAJESTIC BUILDERS SITE ADDRESS: 407,€ S 126 ST DATE: 10 -06 -06 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued �l l M6- ID-U-649 Fire Prevention ft Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Approved with Conditions Planning Division ❑ Permit Coordinator TUES/THURS ROUTING: Please Route C✓ Structural Review Required ❑ No further Review Required DATE: DATE: DUE DATE: 10-10-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 11 -07-06 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License BOBSNNC977OB Licensee Name BOB'S NEW CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602320559 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 2800 THORNDYKE AVE W Address 2 City SEATTLE County KING State WA Zip 98199 Phone 4258899345 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 9/2/2003 Expiration Date 9/2/2007 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date DAN, FREIDBURG AGENT 09/02/2003 OLSON, CRAIG PRESIDENT 09 /02/2003 RANDY, HEAGLE SECRETARY 09 /02/2003 STEVE, CHRISTIANSON TREASURER 09 /02/2003 OLSON, VERN VICE PRESIDENT 09/02/2003 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= BOBSNNC977OB 07/12/2007