Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M06-227 - 7-ELEVEN
7- ELEVEN 14057 INTERURBAN AV S M06 -227 City or/Tukwila Parcel No.: 3365900865 Address: 14057 INTERURBAN AV S TUKW Suite No: Tenant: Name: 7- ELEVEN Address: 14057 INTERURBAN AV S, TUKWILA WA Owner: Name: THE SOUTHLAND CORPORATION Phone: Address: ATTN: AD VALOREM TAX DEPT, CITY PL CTR E / PO BOX 711 Contact Person: Name: PETER CRELLEY Address' PO BOX 33370, SEATTLE WA Contractor: Name: PRO STAFF MECHANICAL INC Address: PO BOX 33370, SEATTLE WA Contractor License No: PROSTMI072NG DESCRIPTION OF WORK: FREEZER REPLACEMENT: "LIKE FOR LIKE" Value of Mechanical: $12,200.00 Type of Fire Protection: Furnace' <100K BTU >100K BTU Floor Fumace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig/Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial /Industrial doc: IMC- Permit Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ct.tultwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 1 0 0 0 0 0 0 0 0 * *continued on next page** Permit Number: Issue Date: Permit Expires On: V Steven M. Mullet, Mayor Phone: 206 361 -0071 Phone: 206 -361 -0071 Expiration Date:06 /30/2008 Boiler Compressor: 0 -3 HP /100,000 BTU 3 -15 HP /500,000 BTU 15-30 HP /1,000,000 BTU 30 -50 HP/1,750,000 BTU 50+ HP/1,750,000 BTU Fire Damper Diffuser Thermostat Wood /Gas Stove Water Heater Emergency Generator Other Mechanical Equipment Steve Lancaster, Director M06 -227 10/16/2006 04/14/2007 Fees Collected: $304.15 International Mechanical Code Edition: 2003 M06 -227 Printed: 10 -16 -2006 doc: IMC-Permit City tw Tukwila Signature: 1 — ✓ ikeeZ: Print Name: 77ivl • ce,1 /y Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ettukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: MO6 -227 Issue Date: 10/16/2006 Permit Expires On: 04/14/2007 Permit Center Authorized Signature ,, ,1,1,... I I .!� c . Date: I hereby certify that I have read and -x -m e. this permit and know the same to be true and correct. All provisions of law and ordinances goveming this work will b; l om. '= d with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perforr rl9e of work. I am authorized to sign and obtain this mechanical permit. Date: to 7 ‘. 0 6, This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M06 -227 Printed: 10 -16 -2006 City chiTukwila Parcel No.: 3365900865 Address: 14057 INTERURBAN AV S TUKW Suite No: Tenant: 7- ELEVEN 1: "'BUILDING DEPARTMENT CONDITIONS*** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us PERMIT CONDITIONS Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -227 Status: ISSUED Applied Date: 10/11/2006 Issue Date: 10/16/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 7: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions * *continued on next page** M06.227 Printed: 10 -16 -2006 Signature: Print Name: doc: Conditions City Or'Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us 774' cMiefir Steven M. Mullet, Mayor Steve Lancaster, Director I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: / ' • b M06 -227 Printed: 10 -16 -2006 SITELOCATION /� V King Co Assessor's TaxNo.: 3 L57OO�65 ©B Site Address: I �f 5 I w T ER U RAN AVE Suite Number: Floor: Tenant Name:_ _ 7 - E LF eN New Tenant: ❑ Yes X.No Property Owners Name: IRS coval-41-1 C/GRPoa P4T1Ui�J Mailing Address: Zt343Iet —7Z AVFA1UE 5 { CONT ACTPEItSC1N .. d m .h Name: JEHn !'.l"P.11e M Day Telephone: 276 - 361 - 00 7 Mailing Address: ? 3c»e 3337(.7 S 4 --(de_ 1AlPh 9e133 I (. awn hp &Mail Address: Pterer n 4 rrWor_karl •CCW1 Fax Number: 7)6 — 36 % 04 09 GENERAL CONTR ACTOR INFORMATIO Contractor Information fm. M,.i anicd(pg 4) forPhunbiug and Can Piping tlws5» Comp: Name: Mailing Addr Contact Person: )-Mail Address: Contractor Registration Nlmlber. ARCffiTECT OF RECORD: - Alt _ ENGINE OF RECO Q bb CITY OF TUKWILA Community Development Department Pabllc Works Department Pend Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hnp: / /www.ci. tukwila.wit.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" bo: ..... ............. SutIding'Pennit To. Mechanical Per i it x PtumbingtGas Permit No .............................. ............................... ker.+ city y Ardtitcct ofReeord 9 eb32 Zip hp city Day Telephon Fax N xpiration Date: Company Name: Mailing Address: city She 7 W Contact Person: Day Telephone: E-Mail Address: :• umber: plans mast be• wetstamped bq Engiineer alRe Company Name: Mailing Address city Contact P. • : Day Telephone: 1- • ddress: Fax Number: Wmm- Application on La 0-2005 - PenutAppli stion.doc 9-006 .ge lof6 Unit Type: .::: Qty Unit: Type: : - Qty Unit Type: 'Qty: Boiler /Compressor. Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3-15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15-30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP/1,750,000 BTU Repair or Addition to Heat/Re&ig/Cooling System 1 Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator – Commf tnd (d MECHANtICAL PERMIT I[NIFORMATIOltt 4 206431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: F3lor STRF Mrc14AMICA-L 113C_• Mailing Address: PO. f3v)c - 4337n SEArrGe L41 98 133 /'� City State Zip Contact Person: PE TF2 EI.I.Ey Day Telephone: 7.6 — 361 - 0077 7 E- MailAddress :.ci -ter t^nPPO'S'iar -rei Ilan i(4I• 9.)6 - 36 1- 0 Contractor Registration Number: Pre--v Sr / 0 72-N 6 Expiration Date: 6, 3 0 - ce Valuation of Mechanical work (contractor's bid price): S )2, 2 00 � Scope of Work (please provide detailed information): Fitea DtE1Z step L ALM E W "Jr: "Jr: Lt K-E - FU2- U KE N Use: Residential: New.... ❑ Replacement .... Commercial: New.... ❑ Replacement ...X Fuel Type: Electric a Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: Q:wppicetioe.Wmes -nq8 to sOo nro0-2006- Permit A,$iaanw,.aoc Revised: 9-206 bb Page 4 of 6 PERMMIIT APPLICATION NOTES — Applicable to a Permits in lies application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Ran Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. puildina and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbic Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE AUTHO • e. t Signature: Print Name: Mailing Address: AGENT: AL to Date Application Expires: 04 (� 1 Date Application Accepted tO I" I Q'avett"&rla e-Appticmu On limn -2006 - Pe®tAppaoEmaoc Revised: 9-2006 m Date: Day Telephone: ZO 6 -361-007 1 Roc 3337n Sliccrn E WA 9 0133 Ca Stare Zip Page 6 of 6 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3365900865 Permit Number: M06 -227 Address: 14057 INTERURBAN AV S TUKW Status: PENDING Suite No: Applied Date: 10/11/2006 Applicant: 7- ELEVEN Issue Date: Receipt No.: R06-01606 Payment Amount: 304.15 Initials: JEM Payment Date: 10/11/2006 08:39 AM User ID: 1165 Balance: $0.00 Payee: PRO -STAFF MECHANICAL, INC. TRANSACTION LIST: Type Method Description Amount Payment Check 9883 304.15 ACCOUNT ITEM LIST: Description Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Account Code 000/322.100 249.32 000/345.830 54.83 Total: 304.15 0651 10/11 d9715 —TOTAL 304-1 doc: Receipt Printed: 10 -11 -2006 CITY OF TUKWILA 4ECEIPT PW DCD 304.15 CHECK 304.15 10/11/06 16 16:06 0097 0651 Project: 717 A Type of Inspect n: _ 7 / f r f- 1..1 , Date Called: Address: Special Instructions: Date Want // � a.m. P• Requester: Phone N2 o! — 5/O/59cS33 INSPECTION RECORD Retain a copy with permit SPERIONAO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. (Receipt No.: El Corrections required prior to approval. CO MENTS: //- o4L .471/1) (Date: /r //A ri $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Date: Projec : 7- / tae• -•., Type of Inspect on: 70/ d,. \ ,'g /11‘ 6. Address: - / 1/4 0 57 Ti.. A ,C Date Called: Special Instructions: ' Date Wanted: - �( "'/ m, p.m. Requester: / Phone No: 2o, -, / -ab7/ i INSPECTION RECORD Retain a copy with permit Z INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: (l�Y "�7/i del Crt/C.{12Q1 U Approved per applicable codes. Corrections required prior to approval. ri $58.00 REINSPECTIONl1'EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. !Receipt No.: Date: Project: 7 Fi1.e.4... Type of Inspecti . 7e / ,V r — 4 /Wi Address: / ;c / (14 -h✓I Date Caned: Special Instructions: Date Wanted: 7 ( Requester: Phone No: 7/,- / - -4'7/ COMMENTS: �� / Inspector v Date: 1 INSPECTION RECORD Retain a copy with permit INSPECTION N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (20 Approved per applicable codes. Corrections required prior to approval. $58.00 REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: (Date: File: M06- -V 7 35mm Drawing #1--Z Ptn c. FILE COPY Permit No ._ PO a* P.r PL- A C eM EN LP Low Profile Outdoor Condensing Units h, medium, and low temperature applications with 1/4 to 1 H.F. compressors and R -404A, R -134a, and R -22 refrigerants et-1 a 17438 4057 INty N A re S, uussrnnnne MIN 6,/1t -A Rr_PLACer aNt : Ll+cc -Fort= Lixe RECENED CITY OFTUKWILP OCT 112006 PERMITCENTER MO 224 Hussman Model Number LPL0055EPA Compressor - KAGB-005E-IAA H.P. --°- -„! 1/2+ Vols/Phase it t! 4 ' :' 115/1 MBH at 95 Ambient Tempt Suction Tempendum 96n a Afnpacis 11 Max.Over° s Hato a 15 Comedians (0 -E•) Receiver Oap(lhc.) BO% Fall 13 Approx. 19L(llu.) 270 I it 6 gq . L lie, m -"” 4 ar- ; -4; -4r 1H t- °. 1.2 Liquid f_ 1/4 Bodkin 12 LPL0078EPA KAAB-007E -IAA 3/4+ 115/1 3.8 2.8 1.8 14 20 1/4 1/2 13 290 LPL0078EPP KAAB-007E -CAV 3/4+ 20&230/1 3.8 2.8 1.8 12 15 1/4 12 13 290 LPI0102EPP KALB- 010ECAV 1+ 208-230/1 5.1 3.4 2.2 9 15 1/4 1/2 13 300 LPL0150EPP KAL&015E -CAV 1 -12 208 -230/1 7.4 5.5 3.9 2.7 12 15 3/8 5/8 13 320 LPL0150EPK KALA -015E -TAC 1 -12 208-230/3 7.4 5.5 3.9 2.7 9 15 3/8 5/8 13 320 Hussman Model Number m LPMOD6OEPA Compressor FS43C1E -CAA N.P. Yobs/Phase F 5/8 115/1 MBH at95 T A9n.L5=11 &/apathy 14 11 8 a 1 Comedians 0 liquid "H';: 1/4 D. Suction Receiver pp,.) 825 Feu 13 iiji W • `11;i� 5.7 ao• 4.1 r19° 3.0 LPM0080EPP RS43C1 E-CAV 5/8 20&230/1 5.7 4.1 3.0 8 15 1/4 13 230 LPMOO80EPA RS55CIE -FM 7/8 115/1 72 5.4 4.0 18 25 114 13 245 LPMOIOOEPP LPM00333IA RS84C1E -CAV AE4448Y 1 208 -230/1 MEDIUM & HIGH TEMPERATURE 1/3 115/1 4.1 8.0 3.2 8.4 HERMETIC 2.5 5.1 10 R734a 60 t1Z 12 15 15 - 3/8 1/4 13 13 245 230 LPM00513JA AK4460Y 9/18 115/1 5.8 42 3.0 13 20 1/4 13 230 LPM00522JA RS40C1E -IAA 9118 115/1 5.1 3.9 2.9 12 15 1/4 13 230 LPM00752JA FS54C1E -IM 3/4 115/1 7.5 5.4 3.8 15 20 1/4 13 245 . , -. ., MEDIUM. AND HIGH TEMPERATURE HERME10 R22::80HZ LPM01002VP 115L2 -01 O0-CAV 1 206 -2311 12.0 9.8 8.9 14.2 20 3/8 5/8 13.2 245 LP Series Outdoor Condensing ising Units, 1/3 to 1-1/2 H.P° for High, Medium, and Low Temperature Standard Features • All - weather galvanized housing • Energy efficient compressor • Copper/aluminum condenser • Oversized insulated receiver • High -low pressure control • Crankcase heater • Modulating by -pass valve Optional Accessories • Refrigeration line set • Electrical line set • Quick- connect couplings I•- ---- 1/4•-1 1 131 �' I•-- - 281 / 2 1 - 0 I t Deceee rating a% for each 10" htdw emblem. Sr.. rating a% for each ta°F lower ambient aussmrnn• Web Site wwewhunmann.comt %mled In USA. 0 2[03, 2001. 1998 Mtssrrann Corporation 0311 -PDF • Visible sight glass/dryer • Low ambient fan control • Dual condenser fans • Coated condenser • Pump solenoid valve • External power switches • Full access to all components Limited Warranty One year against defective material or faulty workmanship, including labor Five years against failure of compressor. 42• 90 7/8"--.1 Hussman Corporation 140 East State Street Gloversville, WY 12078 (518) 725-0644 (800) 753-7790 Fat (518) 125 -3801 c OVT1,00 t tie reeerweeatg t to change or rareaepadrerbm and product design in connection with any feature of as products Such changes do nct slab the buyer to corresponding changes, iTprawnent4 acetones, or nphoamerls tor puprnent previously add or shipped. lagersollitaed bUSROS3 Prawn rota¢ Proven solutions. Narrow Reach -in 2 3, 4 and 5 Door Models INNOVATOR Doors Standard Dimensions shown a In. & (mm). RI-N 36 5 /a (035) RlNN 3.4'3/4 {e73) P/N 0435490C NOTE: The bumpers are 4 in. (102 mm) wide. The center of the bumps is 5 7 42 in. (140 mm) from the Boor. NSF Cerdfcation: These merchandisers are manufactured to meet ANSI/National Sanitation Foundation (NSF") Standard 4(7 requirements. 114000R_ ri r_ZC2 impact RLN With INNOVATOR Doors Frozen Food ` &ice Cream REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% ltH. FF IC Discharge Air ( -5 -12 Evaporator (°F) -11 -19 Unit Sizing (°F) -14 -22 EMtr/Door* FF IC Parallel 1300 1370 Conventional 1325 1400 *For all refiigeration equipment other than Hussman, use conventional Btu values.. DEFROST DATA FF IC Frequency (hr) 24 24 Defrost "Water fb /DWday) 1.2 11 (±'1596 based on case configuration and product loading) Etecrafc FF IC 7emplbrm ( 48° 48° Falbare (minutes) 40 40 Gas Duration (minutes) 20 20 OFFrr.11a Not Recommended CONVENHONOALCONTROLS Low Pumice Bickup Control FF IC CUCO (limp °F r* - 18°/ -34 °- 261-45° Indoor Unit Only, Pressure Defrost Termination (Temp °F)s° Not Recommended "'Use a'lemperature Pressure Chart to deterniinePSIG conversions. PHYSICAL DATA Drip Pipe Um) 1 1 /4 Liquid Line (in.) r/s Suction Line (In.) r/s Estimated Charge (ib)ss* 2De 11 3Dr 2.7 4Dr 3.6 SDr - 4.6 ***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound. Length Added to Lineup by each Standard End (in.) 2 Optional =End with Window fin.) 1 I/2 OptionalPartition (In.) I /2 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 3 of 6 Engineering Plan n 'Views Reach4n Narrow 2,3, 4, 8 `3Door 1W 01 II II RLN &RMN Plan View 3 ! 1 1 1 � 48 I Lr SkidrExtemalBase i419) /- on — 4n21 ter Seal (see note "ry Front Location Door Shown TN000g._ F tc --(L 01-2003 Dimensions shown as in.!. (mm). 3/mei 4 ne4 .I ^L t r .ji 28 I 6 I I I I lri iisni I 1 3 I l 30% i .` __ .0.� (rra) I i _ _ Rerrig.0ulret 35% t sea note '1 39 (1010) 3751 General (A) Case Length (without ends or partitions) Maximum 0/9 dimension of case back to front (Includes bumper) Back of case to rear of splashguard Width of Skidrail Width of Bottom Front Support Stub -up area between front skidrail and splashguard Electriad Service Rfl end of case to the center of nearest knockout ( S) RH end of case to the center ofLH knockout Back 0/S of case to center of knockout •NOTE :: Electrical field Wiring Connection Kira is at terminal. Waste Outlet 0 (C) Right end of case to center of waste outlet Back 0/S of case to center of waste outlet Refrigeration Outlet RH end of case to center of RH refrigeration outlet Back 0/S of case to center of refrigeration outlet 2 Dr 62 (1575) 39 3 /4 (1010) 35 3 /s (899) 4 6 (152) 6 3 /s (1000) 4 (102) 58 (1473) 37 5 /s(956) 5 3 /s (137) 28(711) (D) Outside bottom front supports from end of case 6 3 /4 (170) Center bottom front support from Centerline 24 (610) Distance between Center and Outride supports will vary 3 Dr 92 (2350) 39 (1010) 35 1/4(899) 4 1/4(114) 6 (152) 6 3 /s (1000) 4 (102) 88 (2248) 37 5 /x(956) 23 3 /4 (603) 54 1 /4(1378) 34 (879) 34 (879) Water Seal Edge of seal to center of waste outlet 11(279) 11(279) Outside diameter of drip piping 1 1 /4(32) 1 1 /4(32) "NOTE: Field installed water seal outlets, tees, and cormectors ere shipped with case 5 3 /8(137) 28(711) 6 24 (610) 4 Dr 122 1 -/s (3121) 39 3 /4 (1010) 35 (899) 4 (114) 6 (152) 6 3 /e (1000) 4 (102) 118 7 /a (3019) 37 5 /s (956) 46 34 5 /s(879) 11 (279) 1 5 3 /s(137) 28 (711) 6 3 14 (170) 24 {510) 5 Dr 153 3 /3 (3896) 39 (1010) 35 3 /s (899) 4 1 /2 (114) 6 (152) 6 3 /8 (1000) 4 (102) 149 3 /s (3794) 37 5 /s (956) 76 5 /3(1946) 34 5 4 (879) 11(279) 1 1 /4(32) 5 28(711) 6 3 /4 (170) 24 (610) 2 of 6 NUSSMANN CORPORATION, Bridgeton, MO 63044 -2483 USA RLN with Innovator Doors Data Sheet Set impact RLN With INNOVATOR Doors Frozen food & lee Cream Electrical Data Number of Fans Amperes Merchandiser 2Dr 31h 4Dr 51h Fans Standard 1.40 2.10 2.80 3.50 110 165 220 275 Energy Efficient 0.76 1.14 132 1.90 50 75 100 125 (Export 220V 50 bz) 0.76 1.14 132 1.90 108 162 216 270 Anti -sweat Heaters Doors 134 2.31 3.08 316 185 278 370 463 (Export: 220V 50 hz) 0.84 1.27 1.69 2.10 186 279 372 465 Frames (Export 220V 50 hz) Minimum Circuit Ampacky With Standard Fans 3.90 5.77 7.63 9.51 With Energy Efficient Fans 3.18 4.73 6.27 7.83 Maximum OverCunent Protection 20 20 20 20 (Export: 220V 50 hz) 20 20 20 20 Defrost Drain Heaters (120V) (Export 220V 50 hz) 208V 10 Electric Defrost 8.20 13.0 18.0 22.8 (Export: 220V 50 k) 8.70 13.8 19.0 24.2 Standard Vertical Lighting 2Dr 311r 4Dr 513r Innovator*.. Doors (120V) 1S0 2:00 23 3.00 (Export 220V 50 hz) 4.84 1.12 140 I.48 t Innovator or Innovator II : ilussmann.reconimends against frame heater cycling with .:Janovatardoors .to. pteventloor seals from freezing to the tramesand tearing. 2Dr 31h 413r 5Dr 2 3 4 5 0.78 1.18 1.57 1.97 0.43 0.64 0.85 1.07 0.63 1.25 2.00 2.57 0.34 0.76 122 1.53 Watts 21r 3Dr 41r 5Dr 94 141 188 236 94 141 188 236 75 150 240 300 84 168 269 336 1706 2720 3734 4750 1909 3043 4177 5314 2Dr 3Dr 413r Mr 180 240 300 360 185 246 308 370 4 of 6 HUSSMANN CORPORATION, Bridgeton, MO 630444483 U.S.A. RLN with Innovator Doors Data Sheet Set 120V POWER 4 PIN 0435490C Fan and Neater Circuits - Electric Defrost (standard) Low Temperature CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R —Red P— Purple 2P— Porpie(2 Bands) - DB =Dark Blue B =Black BR =Brown Y- Yellow OR =Orange NV -.White TNESEARE MARKER COLORS (WIRE MAYVARY.) 208Y 120V POWER 4 Low Temperature with Electric Defrost I 1 R -R R l 3 Rear Defied Heats R R Front Defrost Heata R 1 R Fan Relay O N.C. C°afna' +r Fns Off Fm Relay Rad Hatcr(Chmit0 gyp.( rv N.o. v Y Relay Centro; O AS. Relay° at D ] a COIL AS.ReIry© 'T CAN 1 R EvapomtmFm Relay Coil R DefostLiout s O.OR N.C. Finae AS. Fans P— AP-0 —P Markt Hayes 2P —0 -2P 208V 4 Switch OR —O MEW WIRED Dertai Thaaamt O D CA D R. DR— — Terming! `Blocksin Raceway 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1i SS R R S - P 2P R R a oR OR 2P - P w Y BR NEnrRar. 1 JUMP= HEATERS Removable Extemal , FANS& AIL iamrS Lays FANS ' &A (p S.atwe (288V) 3i® (120V) 01) tH 20.maH CAUTION: Whenmu HnUs_n merchandisers equipped with defrost heaters, Ifbranch circuit overeaten protcSanislatgerthan the individualmare 'hmdi.ser'a:defrost (3Teait load, them additional supplemental supp] entat ovetcuuratprotecdon may berequ red per NEC Articles 210 240. Referte ItowvatorReach -In Class Door, Installation and mu Service nval PIN 0425683, for Imrauator door and frame replacement parts. Derma Taromaam w TN ores Rah a° a 1Lev F (Optiara1) v k Fadeams Ihdt Dark Blue Electric Defrost Sequence - Low Temperature 1. Power from the defrost contactor energizes Defrost Heaters and 208V Evaporator Fan Relay Coil (7). Relay Contacts open the fan circuit and energizes the Drain Pan Heater. 2. If the Defrost Heater raises internal air temperature above 90°F, the Defrost Lint Thermostat(4) will open. 3. Temperature rise of the evaporator closes the Relay Control Thermostat (5) at about 35 °F, energizing 120V A.S. Relay Coil (6). This relay's contacts open the Frame and Door Heater Circuits. 4. When Defrost Termination Thermostat ends defrost period, the defrost contactor opens the Defrost Heater and Evaporator Fan Relay Coil Circuits. The Dmin Pan Heater goes off and fans are on. 5. Temperature fall of the evaporator opens the Relay Cemtrol Theimostat (5) at about 20°F, de- energizing 120V A.S. Relay Coil (6). A.S. Relay Contacts close the Frame and Door Heater Circuits. HUSSMANN CORPORATION, Bridgeton, MO 63044 -2483 U.S.A. 5 of 6 03 -01 -2007 PETER CRELLEY PO BOX 33370 SEATTLE WA 98133 RE: Permit No. M06 -227 14057 INTERURBAN AV S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206- 431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writinr and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 04 /14/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, XC: Permit File No. M06 -227 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206-431-3665 .,., PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M06 -227 PROJECT NAME: SITE ADDRESS: 7- ELEVEN Response to Correction Letter # 14057 INTERURBAN AV S DATE: 10 -11 -06 X Original Plan Submittal Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: � 0 i* Bu Id g vision Public Works Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete U Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: LETTER OF COMPLETENESS MAILED: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/rouling slip.doc 2 -28-02 Incomplete ❑ Structural Review Required Approved with Conditions 7 / 41 Fire Prevention Planning Division No further Review Required DATE: DATE: ❑ Permit Coordinator ❑ DUE DATE: 10-12-06 Not Applicable ❑ DUE DATE: 11-09-06 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License PROSTMI072NG Licensee Name PRO STAFF MECHANICAL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601038859 Ind. Ins. Account Id 52073600 Business Type CORPORATION Address 1 PO BOX 33370 Address 2 City SEATTLE County KING State WA Zip 98133 Phone 2063610071 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/7/1993 Expiration Date 6/30/2008 Suspend Date Separation Date Parent Company Previous License PROSTHA136NJ Next License Associated License Business Owner Information Name Role Effective Date Expiration Date ALMO, LEONARD L PRESIDENT 08/07/1993 ALMO, PENNY VICE PRESIDENT 08/07/1993 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 Nor Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond a7 Bond Company Name TRAVELERS CAS & SURETY CO Bond Account Number 103645389 Effective Date 08/07/2001 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount 512,000.00 Received Date 07/30/2001 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= PROSTMI072NG 10/16/2006 REVISIONS • DRAWN p.c. • DATE 45' cot3.r IUKWILP OCT 1 1 2006 PERMIT CENTER • SHEET 220,11.UMBER M 1 ;1.*•';' •' • ; ' '"•\., • 36590022r ,;•••:;:::•";;.• • • 7 :•;,.• • ' ';•••' .336690023(V:: • ' • • 33659 . I r • 4C12085 Kii ' ' ••••• • • • ••• • '' • •i.6.9ocis • ,...••••: .-• • . . . ....... •• '' ' ••••• .• . • , • '; • • ;• // 3255iI83LI • 33659-0G •\ • REPLACE THE EXISTING ROOFTOP INDOOR FREEZER'S REMOTE CONDENSING UNIT WITH NEW. "Like-for-Like" Replacement. 336.55 . 3365.9f. SITE PLAN • . : • • • j e . • >e• • ••• / • •••■. 665 .1.• • 336i5 336696015 / " / 3365900856d 3365 . • • : 336500730 .; .1 • •• ' • ' ; DuWatili511 • 3,1M5 ''''' •••• • •:; ; • 142304 . '''''''''' • I. •.• :-..••••••• ''' • • ..• . .• •• ••'• • • : '"; " • ' ' • ' "•• • ' • '' ' ' ' ; • : ' .••:. ' • • • • • • . • • • • ' • • ; • • • • • • , ' r••• :• :•:„: ' 3365401095 : • • approval is subject to errors and omissions. pProval::: • construction declarants does not authorize oration ot any accepted code or ordinance. Receipt • ..approVed Pic.kJ Copy and cond.. ns Is adcnowledged: 3365961515 • ''• '' • 136isioi* ' !. ' '••• • •*, 976 • • : • •• • 336 ?blip • SEPARATE PERMIT REQUIRED FOR a Mechanical <Electrical or Gas Piping City of Tukwila ILDINO.DIVISION FILE Permk No. • /33 City a Tiikwila \ \ -BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE .ppoomict) OCT 1 2 2006 of Tukwila BUILDING OIVISION VICINITY MAP ' 1 111 1111 111_1 1111 1111 1111 1111111.1 1111.1111 1111 1111 1,111 1111 11,111.1.1111 11L1 11.1 HP 1111 J.1_11 1111 1111.11.1.1_1fll 1111 1111 1111 . 1 I I T r I i t I T I t I 11 9 1 9 .1 1 I I I 1 r1 I 1 SCOPE OF WORK: • Replace one existing indoor freezer and remote rooftop condensing unit with new. "Like-for-Like" replacement. • Replace the existing refrigerant piping. • Start-up & test. Parcel Number: 3365900865 • Legal Description: 21-28 8 HILLMANS SEATTLE GARDEN TRS LESS ST Inch 1/16 1 11 I 1 11 i 1 11TiffiT Firrarl • ` 21 • - 3 I 41 • .1 1 1 I I I 'N- al 11 i 1 I 61 11 1111 1 i"i 11-1 ilia 1 : • • • REVItgliONS No changes shall be made to the scope 07 work without prior approval of Tukwila Building DivIsEan. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REPLACE THE EXISTING ROOFTOP INDOOR FREEZER'S REMOTE CONDENSING UNIT WITH NEW._ "Like- for - Like" Replacement. iiV1 ROOF PLAN. SCALE: 1/8 " =1' -0" , FRONT OF STORE I-P--1 HP -1 I EXISTING ROOFTOP HEAT PUMPS EXISTING REMOTE WALK -IN CONDENSING UNIT ( OVERHANG , PARAPET - TYPICAL REVIEWED FOR CODE CO. 12 2006 My Of Tukwila BUILDING OIVISTON SHEET NUMBER -2 REVISIONS RECEIVED CITY OF - 8.101 A ' • OCT 112006 PERMIT CENTER DRAWN DATE CONTENTS G: 0 / 6 /06 1nif t /16 I Inch