Loading...
HomeMy WebLinkAboutPermit M06-250 - TOLONEN RESIDENCETOLONEN RESIDENCE 14075 35 AV S EXPIRED 5 -12 -07 M06 -250 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 11100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1523049225 14075 35 AV 5 TUKW TOLONEN RESIDENCE 14075 35 AV S , TUKWILA WA TOLONEN ALVIN D 14075 35TH AVE S , SEATTLE WA JIM LEAIR 101 23 ST SE B/2 , PUYALLUP WA Contractor: Name: NORTHWEST CLIMATE CONTROLS INC Address: 101 23 STREET STE B2 , PUYALLUP WA Contractor License No: NORTHCC990P4 DESCRIPTION OF WORK: REPLACE FURNACE, GAS LINES, AND HEAT PUMP Value of Mechanical: $15,600.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heate Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT 1 Fees Collected: International Mechanical Code Edition: 2003 EQUIP TYPE AND QUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 435 -8834 Phone: Expiration Date: 12/18/2007 Steven M. Mullet, Mayor Steve Lancaster, Director M06 -250 11/13/2006 05/12/2007 Boiler Compressor: 0-3 HP/ 100,000 BTU 0 3 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU 0 30-80 HP/1,750,000 BTU 0 60+ HP /1,780,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 $276.98 doc: IMC -10 /06 M06 -250 Printed: 1143 -2006 Permit Center Authorized Signature: 1 hereby certify that I have read and governing this work will be compile City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: htto: / /www.ci.tukwila.wa.us Permit Number: M06 -250 Issue Date: 11/13/2006 Permit Expires On: 05/12/2007 Date: t I l2'Is 0 permit and know the same to be true and correct. All provisions of law and ordinances er specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo ork. I am authorized to sign and obtain this mechanical permit. Signature. V r Date: /O // / Print i ,i e: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M06.250 Printed: 11 -13 -2006 Parcel No.: 1523049225 Address: Suite No: Tenant: 14075 35 AV S TURIN' TOLONEN RESIDENCE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M06 -250 ISSUED 11/13/2006 11/13/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel-fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond - 10/06 * *continued on next page ** M06 -250 Printed: 11 -13 -2006 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Date: /1/# Print Name: _A/i17/ / /!r doc: Cond -10 /06 M06 -250 Printed: 11 -13 -2006 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup: //xnaw ci.niku ila,xn. us Building Permit No. Mechanical Permit No. ( " 241) Plumbing/Gas Permit No. ' 21; Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print•" SITE LOCATION 140 IC- 3S AVt • S . King Co Assessor's Tax No.: 1 - 11- 147-d Site Address: { - TS • - 3 AA/G S • Suite Number: Floor: New Tenant: ❑ Yes (2[..No Tenant Name: 41._ 4 CL4'- tisGTTC TOLOIJCI.J Property Owners Name: flLC CILAUCCITC If�l.0 Mailing Address: I I-10 1 S - 3ST1'i A r S . - mew tltq- WA - S&7 State Zip City CONTACT PERSON — who do we contact when your permit is ready to be issued Name: a % LEA-112- Day Telephone: 253_436 = ep 3 Li Mailing Address: l t ,,� 2QO S1 / S - 8)2_ 01664.4A.,0 utfr 48'3/ 2 �l t • \ A1�@ Q a t _ Fi( Sutc Zip E -Mail Address: C AST- �r Fax Number: 2< � 3 5 895( GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: k)oten41.oeST CU i"1 tow COMI O S , ✓1 C - Mailing Address: 101- 23Q) sr Sr d3 JZ tQvty m440 Wft- q. a3-72_ City State Ztp S ,' Contact Person: r1 L e I✓L- /�; Day Telephone: 2S 21 Y`S 31 E -Mail Address: C 1 LEA11 Cl/ t�SArn C" P S r — Fax Number: 3 - S q S• Contractor Registration Number: NOem CC qQ Or/"'y1 Expiration Date: 1 2 1 1 12-007 ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Mailing Address: State City Contact Person: Day Telephone: E -Mail Address: Fax Number: Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: State cit Contact Person: Day Telephone: E -Mail Address: Fax Number \ 301, 01011. - trnh:.mmi“ yt uuc'. JMm rnni Apphmuni. .c Zip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<I00K BTU I Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >I00K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 1 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP/I,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System f Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10.000 CFM Incinerator — Comm/Ind MECHANICAL PERMIT INFORMATION- 206 -431 -3670 MECHANICAL CONTRACTOR O SW w NTRACTOR INFO a- 11 ATION M n Company Name: ES 1 E +ZO � LS C (] Mailing Address: \O\ " 231/42o sr" SC t .Z AAPRAA4 uQ - 8372 Cit �� Sb / Zi Day Telephone: 2-) 7— tT Or —e8 E -Mail Address: StM Th►2- Qcyb't'tc4s . VcFV Fax Number: 2-0- Y2 ) Contractor Registration Number: /1/C/2f/t C- � f 9U /V Expiration Date: J2 // Y/200'7 Contact Person: • Valuation of Mechanical work (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .... Commercial: New .... ❑ Replacement .... ❑ Fuel Tvvq: Electric ❑ Gas Other: Indicate type of mechanical work being installed and the quantity below: Page 4 of Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder. commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system - per drain (inside building) Water heater and/or vent 1 Additional medical gas inlets/outlets - six or more liT Industrial waste pretreatment interceptor, including its trap and vent. except for kitchen type grease interceptors 1 Repair or alteration of' water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Nc .T WEST t.1 ap- )Mscl I,' ,c, L ^2 sr se - 6-z Company Name: Mailing Address: Contact Person: 1 t L'e�11Z E -Mail Address: o 4 Le A- e CoytCJs • MCI- Sri Contractor Registration Number: hi) cc °/ 90 y 'd ' y 1 ;. 111" P Nnnlm.mmm .,L State Zip Day Telephone: ?-5"3— ?-5"3— Lk) f' gal 8 3 y c' Fax Number: 2 -0 — T h i- V 4 SJ Expiration Date: / s /o 7 City s Valuation of Plumbing work (contractor's bid price): $ &QC> Valuation of Gas Piping work (contractor's bid price): $ 400 � Scope of Work (please provide detailed information): S A 0 s • TY ^ Q „) e e �I S cAnk- Building Use (per Int'I Building Code): Occupancy (per int'I Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quan ity below: Page 5 of6 PERMIT APPLICATION NOTES — Applicable to all permits In this application Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Buildin as nd Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). BUILDING OW s • AUTHORI - D AG ti p Signature: Date: /� /F /O Print Name: \T/M L t ! i!Z Day Telephone: d2 C7 YJ) Y0 3 y Mailing Address: ,r0R -23/20 -23/20 J/ Sr 5- — /VU h t Loa 9f3 ?t_ ity J Slate Zip l Date Application Accepted: it It; lam Lnr I'a nn \nnlicm.m h.. Date Application Expires: Staff Initials: 1 P:NC 6 of Doc: RECSEIS -06 RECEIPT NO: R06 -01804 Initials: JEM User ID: 1165 SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description GAS - RES MECHANICAL - RES PLUMBING - RES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Payee: NORTH WEST CLIMATE CONTROLS, INC. SET RECEIPT Payment Date: 11/13/2006 Total Payment: 452.98 SET ID: 5000000607 SET NAME: Tmp set/Initialized Activities M06 -250 - 276.98 PG06 -213 176.00 TOTAL: 276.98 TRANSACTION LIST: Type Method Description Amount Payment Check 101534 452.98 TOTAL: 452.98 Account Code Current Pmts 000/322.100 88.00 000/322.100 276.98 000/322.100 88.00 TOTAL: 452.98 1677 11/13 9716 TOTAL 452.98 Upf!o lHorizontai Downflow Horizontal Two. stage Condensing Gas -fired Furnace XV 90 TUY060,080,100,120R9V Variable Speed Blower Variable Speed Inducer TDY060,080,100,120R9V Variable Speed Blower Variable Speed Inducer PUB. NO. 22-1755-01-0604 (EN) 22- 1355 - 01.0604 (EN) Contents General Features Features and Benefits XV 90 Standard Equipment XV 90 Optional Equipment General Data TUY060R9V3W TUY080R9V3W TUY100R9V4W TUY120R9V5W TDY060R9V3W TDY080R9V3W TDY100R9V4W TDY120R9V5W Performance Data TUY TDY Electrical Data Field Wiring Dimensions 3 0 TRANE° • • NE MODEL TDY06OR9V3W RATINGS° 1st Stage Input BTUH tat Stage CapadtyBTUH (ICSX] 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICSJD AWE (XS) Tempi :Ise (MIn. -Max.) BLOWER DRIVE IN% (n) No. Used Speeds 03.) CFA vs. h wg. Motor HP RP.M. VdtstPh4Iz OOUBU5faI FAN -TYPE Drive - No. Speeds Mo tor HP -RPM Vats/R*t FL Paps AL1ER— FumWted7 Type Recommended Flier(No.- Sze -Thk) VENT—Size 99 2ROUND HEATELCHANGER Type-Rred -Linked Gauge (Red) ORIFICES —Main Nat. Gas. O( —M Size LP. Gass Cry. — DM Ewe Type BURNERS—Type Winter POWER CONN. —V Mpadty pn Amps) Fuse Size —Max. (Amps) PIPE CONK. a2E lit) DUCT CORN. DWENSIONS Crated (In.) U rastl V/BGHT SNppYg (Los Wet (lda-) 39000 38000 wow 58000 92.0 35.85 DIRECT 10 x 8 VARIABLE SEE FAN PERF. TABLE 12 VARIABLE 1151/70 CENTRIFUGAL DIRECT- VARIABLE 1/50.5000 33- 110/3/60.180 1.0 YES HIGH VELOCITY 2 X 14 X 20 X1 ALUMINIZED STEEL TYPE 1 3.45 4.45 3.56 4.58 GAS VALVE REDUNDANT - TWO -STAGE REDUNDANT - TWO-STAGE OBTECT IGNITION DEVICE HOT SURFACE IGNRER 111-SHOT 3 115190 11.1 15 050 SEE DURNE DRAWING SEE ONLINE DRAWING SEE OUTUNE DRAWING HXWXD 4134 X 1912 X3942 SEE OURNE DRAWING 160/146 General Data 0.50 HXWXD 41-34 X 19-12 X 3042 SEE ONLINE DRAWING O Central Furnace heating designs are certified by AGA and CSA. 0 For U.S. applications, above input ratings (BTU-4) are up b 2,000 feet derate 4% per 1,N0 feet for elevations above 2,000 het above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. 0 Based on U.S. govemment standard tests. O The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 22- 1755 -0t -0604 (ENI 7 TDY -R9V Product Specifications 0 TDYtV3W 52000 48000 80000 74000 925 35.65 DIRECT 10x8 VARIABLE SEE FAN PERF. TABLE 12 VARI 3 E 11M90 CENTRIFUGAL DIRECT- VARIABLE 1/50.5000 33.1103/60.18D 1.0 YES HIGH VELOCITY 2X14X20X1 2 ROUND ALUMNI ED STEEL TYPE 1 HOT SURFACE IGNITER IN 4 it51M0 11.1 15 TDYWOR9V4W 65000 60000 100000 94000 Sao 35.65 DIRECT 10 x 10 1 VARIABLE SEE FAN PERF. TABLE 3 VAR ABLE 115190 CENTRIFUGAL DIRECT - VARIABLE 1/50 -5000 33- 1103 1.0 YES HIGH VELOCITY 2 X18 X 20 X1 3 ROUND ALUMINIZED STEEL TYPE 1 20 5.45 5.56 REOtAJDANT- TWO -STAGE NOT SURFACE IGNITER IN-SHOT 5 1151/X7 13.5 20 0.50 HXWXD 41 -34 X23 SEE DU1UNE DRAWING 168/158 185(175 TRANS* TDY120R9V5W 20 TOY 76000 72000 120000 112000 92.5 40.70 DIRECT 10x10 f VARIABLE SEE FAN PERF. TABLE 1 VARIABLE 1151/60 CENTRIFUGAL DIRECT- VARIAa.E 1150 -5000 3311W/3 1.0 YES HIGH VELOCITY 2X16X20X1 3 ROUND ALUMINIZED STEEL TYPE 1 6.45 6 -56 REDUNDANT- IWO-STAGE ROT SURFACE 'CARER IN -SHOT 6 115190 17.5 30 0.50 SEE OUTLINE DRAWING HXWXD 4134X28. 12X 30.12 SEE OURINE DRAWING 2061196 tY060R9V3W FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FLLTER OUTDOOR UNIT SIZE (TONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 1 $W 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 1.5 LOW (350 CFM/113N) OFF OFF OFF ON WATTS 45 70 525 100 525 135 525 100 NORMAL (400 CFM/TON) OFF OFF OFF OFF CRA WATTS 600 55 85 800 120 800 150 600 185 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 675 65 875 105 625 140 675 175 675 205 2.0 (350 CRANON) ON ON OFF ON WATTS 70 700 15 145 185 220 NORMAL (400 CFM/TON) ON ON OFF OFF CRA WATTS 800 100 800 135 175 225 280 (450 OF ) ON ON ON OFF WATTS 125 185 220 270 330 2.5 LOW (350 CFM/TON) OFF ON OFF ON CFM WATTS 875 115 875 160 875 210 875 280 875 310 NORMAL (400 CFMTON) OFF ON OFF OFF CFM WATTS 1000 150 1000 207 1000 265 1000 320 1000 380 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1125 215 1125 285 1125 340 1125 395 1125 440 3 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1050 175 1050 240 1050 305 1050 345 1050 380 NORMAL (400 CFMTON) ON OFF OFF OFF CFM WATTS 1200 240 1200 315 1200 385 1200 440 1100 410 HIGH (450 CFINTON) ON O OFF CFM WATTS 1350 330 1350 410 1350 500 1275 485 1170 450 NOTES: • RrM latter 1. At continuos fan 2. ( NORMAL L HIGH aNBoww ((4 may be 'A' or T aatdng Heating or Coollna airflows are approximately 6 Y 50%01 selected scans Sue. HUMID CLIMATE setting; w 450 (400 cfmion it A sOMon) Y DRY CLIMATE setting. 'DY060RSV3W FURNACE 1HEATIFJG AIRFLOW (CFM) AND POWER ( WATTS) V8. EXTERNAL STATIC PRESSURE WITH FILTER 1st STAGE CAPACITY sr 37400 • 2nd STAGE CAPACITY • 68.000 AIRFLOW SETTING DIP SWTCH SETTING EXTERNAL STATIC PRESSURE SW 7 SW 6 0.1 0.3 0.5 0.7 0.9 HEATING STAGE LOW ON ON TEMP. CFM ISE WATTS 58 55 56 85 58 120 58 150 5 185 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 875 50 85 675 50 105 875 50 140 575 50 175 575 50 205 NORMAL '• ON OFF TEMP. RISE WATTS 45 85 45 125 45 160 45 210 46 260 HIGH OFF OFF TEMP.RISE WATTS 40 115 850 40 155 850 205 4 280 40 320 HEATING 2ND STAGE LOW ON ON CFM TEMP. RISE WATTS 900 58 125 900 58 165 900 58 220 900 58 270 900 58 315 MEDIUM LOW OFF ON TEMP RISE WATTS 1000 52 170 1050 50 230 1050 50 295 1050 50 335 1 50 370 NORMAL •• ON OFF CFM TEMP RISE WATTS 2060 51 880 1990 53 890 1850 57 810 1710 61 750 1530 68 855 HIGH OFF OFF CFM TEMP. RISE WATTS 2200 48 1030 2090 50 965 1940 54 895 1190 58 830 1640 64 750 NOTES: • First letter ma be 'A' or 'T" •' Factory setting 1 1 1 r 3 9 TRAJIE Performance Data °DY 12 22- 1755-01 -0604 (EN) pAOIR05TIC CODEA (SEE NOTE 13) RED (E0 - 1,9.1.11 Is 0.11 - 1 FIp1 tasty 20 Aec nb 2 SLASHES - SYSTEM LOCKOUT RETRIES 01 RECYCLES (SCEEO(D 5 FLASHES - 115 VOLT AC POWER REVERSED 01 16AITER FAULT 3 FLASHES - PRESSURE 511701 FAULT 1 FLASHES - 005 VALVE CIRCUIT ERROR 8 FLASHES - LOW FLAME SENSE SIGNAL 4 FLASHES - OPEN LIMIT SWITCH S CLASSES - OPEN INDUCER LIMIT 5 FLASHES - FLAME 5EI5E0 WHEN 10 FLAME 5110010 BE PRESENT 10 FLASHES - INDUCER CdMUMICAIIW FAULT CONTINUOUS ON - INTERNAL CONTROL SAMURE GREEN LED - STATUS SLOW FLASH - NORMAL. NO CALL EON NEAT FAST FLASH - NORMAL CALL FOR NEAT 11(5[11 GREEN AND RED LEDDS ON CONTINUOUS - FUSE OPEN ON INTERNAL CONTROL FAILURE 11C r - — - � I NUN -N EAC-1 LIME -N CER -N 07MR -1 CIRC -H LIME -11 0FMR -N FP EAC - NUM -X 1611 IGN TN T R GNU PILO 41 ILI P52 P5' P50 MVH VL © 0 0' I � w O ' 0 1L 0: it O' 0 w 111 ROI 11 1 IC ND00' FA N MOTO R n 16 1 0 FLAN( 5(1150R I4 t1 L � GR /B j JUNE( 6110 TURN vc 22- 1765 - 01.0604 (EN) 1 6ND RD/ BA 12 NI R G 5/C Y Yl0 0 II InI % %r� \.49- shJ�AJUAJMJLJ L•IN NLR E1a1I�®' H(RMOS TAT 115 VOLT 60 HZ. 1 PH POWER SUPPLE PER LOCAL CODE 0 SAFETY WA /5 DH/5 51 1 100 ENEMA i CUT WT 6 ' 0 y /S n(SSUSE S 5111[11 I r (9 PLANE SCUM 1 j _.. f GRASSES 0000X0 1 - NS1 NOT SURFACE IGNITER RD �> •' I 0 0 UW1 SNIICH DL D N • R cn.0 TIME TCO•C I_.. _.. _.. _.. _.._.. _. _.- _.. —.. _.. _.. -. 1 P _JEWS JTC� / .A ANT OF ENE ORIGINAL 111116 AS fun 1(0 AIFM MIS FURNACE MUST BE REPLACED, /5 I I 71/4 OR 1L /1 ORS I 1/ 1/1 S ST BR /1 SN BU 1 T r 3EE NOTES 2. J. 5. 6, 1 8 9 Schematic Diagrams For Gas Furnaces TDY060,080,100,120R9V -W E —_J Y WH/ 1 1 Electrical Data 57 INDUCER f - ` - 1 LIMIT GAS I SWITCH VALVE I TCO -B MEG �\ RATEO - Teach ONTRq_ C REPLACE WITH WITH PART CO1 03110 00 EWIYALEN INPUT; 2 N.A.Lffi 50 112. P0 5 SECOND ERPUIG S E 60 SEC. IFNI SEC. CURRENT: 150 NI. • W 10A0 IGNITOR WARNUI: 20 SECONDS MY OUTPUT: II A 0 21 V.A.C. IAA: 3; T(I: 5 SECONDS TO RCN ; UM OUTPUT: 3 PHASE OUTPUT RETRIES: 2: RECYCLES: 10 AM 1611 OUTPUT; 2.0 A 0 120(4.51 C. HEAT 011 DELAY: 4S SECONDS CONY 01 1 CI IC. BLOWER OUTPUT: 4,5 fl A, COW 011 DELAY: 0 SECONDS 25 L1A 8 121 MAC AUTO RESTART: 60 MINUTES HW101(ER A Alf CLEANER AUTO RESTART PUCE: 15 SECONDS NAT. LWO: I.0 A 8 120 MAC WARNING/1\ HAZARDOUS VOLTAGE DISCONNECT ALL ELECTRICAL 90NE0 11CLUDINO REMOTE DISCONNECTS BEf01E SERVICING. FAILURE TO D15 011EC1 POWER BEFORE SERVICING CAN CAUSE SEVERE 9105WAl 1 0100! 00 DEA1N. (R5 (LANG ROLLOUT SNITCH CF c *ACIIOW COIL 9111 }FACTORY 24 V 11111116 -__ -LINE 1nELU - --21 WIRING No PROTECTION TIERMAL CAUTION /f\ USE COPPER CONDUCTORS 04191 UNIT TERMINALS ARE ROT DESIGNED 10 ACCEPT OTHER TYPES OF CONDUCTORS. F A1LU0( TO 00 50 MAY CAUSE DAMAGE 1 0 THE E00IPNE /1. L LINE N NEUTRAL 610 WOUND O/C CORON MO MIW LIMIT OUTPUT M I MGR 1EMIT 111901 BO BLACK AH WRITE 91 YELLOW W ONANO7 6A 60(1* OR BPONN 0D RED BL BLUE ' COLOR BA/1 -- --moment ID (IF ANTI 11 21 VAC (Pei) TR 24 VAC IC00101) NV MIN 6AS VALVE T55 TRANSFORMER 1(I 1NDOCER LIMIT INPUT 2. [ If 5[1 106 1 R SETTING: 1 MDT1ISED ON THERMOSTAT MIST STAGE . 3 AT FON 5116(ES AMPS, THERMOSTAT AMPS. MOSTAT 5 AT .51 MOS. 3. FOR PROPER OPERATION OF COOL UK SPEED •1 TERMINAL MUST BE CONNECTED TO 111E NOON E1NRNO57A /. 4. THESE LEADS PROVIDE 120V POWER COWNEC IONS FOR ELECTRONIC AIR CLEANER IEAC1 AND HUMIDIFIER I11UM1. MAU FWD: 1.0 AMS (ACA 5. JUMPER 11 AND 62 700 SINGLE STAGE NEA 156 THERMOSTAT. SECOND STAGE WILL BE ENERGIZED. DELAYED PEA STAGING DEL 1 SETTING. 5 GREEN LIGHT ICFM1 FLASHES ONCE PER 10 CPN COMMAND. 7 FOR NEAT PUMP 5159015 1 *110 0 MOST BE CONNECTED TO TAE LOW -YOU 1516E T[1N1 ML BOARD. 8. FOR 9NO SPEED 575TEMS, USE 7L0 FOR 100 SPEED AND 9 FOR 111tH 59(10 CON1(CT101 TO 151E LOW- VOLTAGE 1EW111A BOARD. 9 OPTIONAL 101105TA7 IS TO BE CONNECTED BETWEEN THE •R• AND 'BR' FACTORY INSTALLED IS lUMPEO USED. .THE IUMPEI 1 ALSO I CUT HEN APPLYING Al AIRFLOW CUT LOW COWA00 SIGNAL A LTO AF THE 9 811' INPUT SUCH AS 51111 THE VARIA L( SPEED SINGLE-ZONE AND Will-ZONE SYSTEM CONTROLLERS ON 51NGLE SPEED (001I0G ONLY / MON -HEAT RUMP SYSTEMS. /WIPER •1' TD '0 100 PROPER OPERATION Of 111E DELAY PROFILES AND THE 4UM1051AT FOR TWO COMPRESSOR OR 1110 SPEED SYSTEMS, JUMP R - YLO' 10 '0'. :7 SEE 150000 NO100 AIRFLOW SELECTION C ART. LOCA110 IX 14( FURNACE FOR 01P SWITCH 5(911MG5 TO SET AIRFLOW AND COOLING OFF DELAYS II POWER MUST BE Off WHEN DM SWITCHES RE 5E1 ;? USED 100 •0110009(44. 4X0 0011200915. 100(13 ONLY. IJ ON PWE1-49, LAST FOUR FAULTS. IF AN . WILL BE FLASHED ON RED LED GREET LED WILL BE SOLID ON DURING LA 1' (AULT RECOVER) From Dwg. 21D342119P01 Rev. 1 TRAIVE° Field Wiring TO IISV 1 PH., W IQ, POWER SUPPLY PER LOCAL CODES 111Y SEE NOTES FIG GIE NOTES .. IH I� r ift., ANNA .m—o Field Wiring Diagram For Single -Stage Heating NOTES: S10UN0 `SC4Ew FURNACE 12 1 JUNCTION r ---1 1 BOX Y 1n R51n 1 I c I O O FURNACE THERMOSTAT TERMINALS F[ 1011 NOTE DIP SWITCH — 1. BE SURE POWER AGREES WITH EOUIPMENT NAMEPLATE'S' 2. LOW VOLTA0E124 V. WIRIN01 TO BE N0. IS A.W.O. MIN. 3. GROUNDING OF EOUIPMENT MUST COMPLY WITH LOCAL CODES. A. SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM. 5. THESE LEADS PROVIDE 115 Y. POWER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND HUMIDIFIER MAX. LOAD 1.0 AMPS EACH, S. ISEUSEO. SINGLE 0 RI O " HEATING ' ERM INAL (55 WITHOUT FAN SWITCH USED. 7. Wt AND 112 MUST BE JUMPERED TOGETHER FOR PROPER OPERATION. SECONO STAGE NEAT WILL BEGIN 10 MINUTES AFTER FIRST STAGE. S TD AIRFLOW AND 1110001* FAUN OFF DELAYS CATION INSTRUCTIONS 9. CONTINCUS FAN AIRFLOW CAN SE INCREASED SY ADDING THIS JUMPER. FURNACE INTER - COMPONENT WIRING fACTOMT J LED THERMS STATE HEAT NG THERMOSTAT WITH SAM SWITCH TERMINALS. 2A V. FA[TORr V. 11141110 LINE Jove From Dwg. 218341127 Rev. 0 TO HIV 1FH., NHL POWER GUPPLYPER LOCK 000!8 1 GEE NOTES GIC SEE NOTES Field Wiring Diagram For Two -Stage Heating Thermostat 1 GRWNO 1 SCREW FURNACE �( JUNC TION I r--' 1 sox IN Mf in 1I 1 r - .14 1 Ma �J ; 1_11_J L CIINTEGRpALLTED FURNACE THER405TAT TERMINALS •AW A 7 S1 DIP SWITCH 1 NOTES: 1. GE SURE POWER AGREES WITH EOUIPYENT NAIAEPLATEISI Z. LOT VOLTASE124 V. W141N01 TO 9E N0. 15 A.W.O.. YIN. 1 3. OROUNOINO OF EOUIPMENT MUST COMPLY WITH LOCK CODES. 4. SET THERMOSTAT HEAT ANTICIPATOR PER UNIT MIRING 01ADAM. S. THESE LEADS PROVIDE 115 V. POWER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND HUMIDIFIER MAN. LOAD 1.0 AMPS EACH. j S TO SET AIRFLOW AND 1N0004 FAN 04* DELAYS. CATION INSTRUCTIONS I 7. CONTINUOS FAN •14FLOR CAN WE INCREASED ST *WINO THIS JUMPER. INTER-COMPONENT WIRING 24 V. FACTORY ' FURNACE LINE Y. MIMING NV. JFIE� O LINE V W1 R�F0 PACTOY INSTAL 2 STAGE HEATING THERMOSTAT WITH FAN SWITCH TERMINALS. From Dwg. 218341126 Rev. 0 18 22- 1755- 01- 0604(EN) 1 1 1 1 TRAIN` Field Wiring TO 1tSv1 PH, b POWER 4 ' SUPPLY PER LOCAL CODES LN wH HUM SEE NOTES BX SCREE r NOTES ) Elk POWER SUPPLY r.iii _UNIT 1 1 e� r LH 11 POWER SUPPLY Ij� r - UMT 1 B -J LY�1 LOW VOLTAGE AIR CONDITIONING OUTDOOR SECTION WITHOUT TRANSFORMER Field Wiring Diagram For Two-Stage Heating Two -Stage Cooling (Outdoor Section Without Transformer) NOTES: GROUNO SCREW FURNACE BX JUNCTION BOX BN in WH DIP SWITCH INTEGRATED URNAACE CONTROL or USUOIOO ROI THERMOSTAT TERMINALS ner TaE HiT4lr a •2 NI • 0 Y VLO Y R OVER SEE NOTE 7 hacitahtstestia NOT 6 I. BE SURE POWER AGREES WITH EQUIPMENT NAMEPLATEISI 2. LOW VOLTAGEI24 V. WIRING' TO BE 110. IB A.W.O. MIN. 3. GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 4. SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM. 5. THESE LEADS PROVIDE 115 V. POWER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND HUMIDIFIER MAX. LOAD 1.0 AMPS EACH. S. THIS WIRE 15 ONLY FOR THERMOSTATS REQUIRING CONNECTION TO TRANSFORMER COMMON TERMINAL. T. THE 'V2' TERMINAL FROM THE THERMOSTAT MUST BE WIRED ro THE 'Y' TERMINAL OF THE FURNACE CONTROL FOR PROPER SLOWER OPERATION DURING COOLING. INTER - COMPONENT WIRING 24 V. FACTORY V. WIRING 24 V. FIELD LINE V. RJR )NG FURNACE 2 STAGE HEATING TWO STAGE COOLING THERMOSTAT WITH FAN SWITCH TERMINALS B. SET DIP SWITCHES WITH POWER Orr PER INSTALLATION INSTRUCTIONS TO SET AIRrLOW AND INDOOR FAN OFF DELAYS, 9. OPTIONAL HUMIDISTAT IS TO BE CONNECTED BETWEEN R AND BK. FACTORY INSTALLED JUMPER R TO 8X ON THE CIRCUIT BOARD MUST BE CUT IF OPTIONAL HUMIDISTAT 15 u5E0. THE JUMPER MUST ALSO GE Cur WHEN APPLYING AN AIRFLOW COMMAND SIGNAL TO THE BA INPUT SUCH AS WITH THE VARIABLE SPEED SINGLE -ZONE AND MULTI-ZONE SYSTEM CONTROLLERS. ON SINGLE SPEED COOLING ONLY /NON-HEAT PUMP SYSTEMS. JUMPER Y TO 0 FOR PROPER OPERATION OF 11 DELAY PROFILES AND THE HUMIDISTAT. FOR TWO COMPRESSOR OR TWO SPEED SYSTEMS. JUMPER YL0 TO 0. From Dwg. 218341126 Rev.0 20 224755 -01 -0604 (EN) ANN7EL o r :1i 1 DIM 'A' DM - Er DM - c' DM '0 ADY060R9V3Y080A9V3NNR PD 17 -1/2' 2 -1/4" 16 -1 /4' 16' 110VI00R9V4444 21' 2 -1/2' 19-3/4' 19 -1/2' 0 0T12ORSvS.4N 24 -1/2' 2- 15116" 23-114' 23' wmog 5/8' DIM r 5/8' HORIZONTAL CONDENSATE DRAIN I -7/8 x 1/8' SLOT KNOCKOUT 01/8' - ELECTRICAL SUPPLY 3 4. 112' +{ 19 5/8 /- 1116' 663' OPENING AIR INTAKE 3.3/4" 5-5/16' 28' 4 1 - 112' GAS CONNECTION (ALTERNATE/ KNOCKOUT I DM 0" OUTLET AIR 314'j 3/4' � 19-9/16' 02' FLUE 6ALLINMENIEWNSAFFER4114WES) SEE N NOTE 1 0NA 'R' 1/2' 2 -1/8' 51/2 3-15116' -- 10" 11118' 1 3/4 TDY -R9V -W DowMiow /Horizontal Outline Drawing 7-3/8' CONDENSATE ORA N 1/2' 01 -5116' KNOCKOUT OR1ZONTAL APPLICATION /THIS SIDE ONLY/ 1/2' E+- DM 'A' 40' 3' CONNECTION AIR INTAKE 2 -1/16' r 10' 1 -3/8' __.1 2-13/16' I PREFIX MAY BE • • OR •1• NN SUFFIX LETTER MAT BE 'D• - 0 7111111 1 Iu SUFFIX LETTER MAY 8E '1' - 0 INRU 1 D57/8" ELECTRICAL CONNECTION (ALTERNATE/ 0118' ELECTRICAL CONNECTION (ALTERNATE/ KNOCKOUT NOTES: I. 10A2-I12" OR 3 ' 011 PIPE � MODELS I AT 7 DIFFERENT ALTITUDES. REFER 70 THE VENT LENGTH (ABLE FOR PROPER APPLICATION. 01 -1/2' GAS CONNECTION 01 -I /8' CONDENSATE DRAIN KNOCKOUT NARau m FARABN TO IM F MAT RIA V310( SIDES 0 IN NEAR 0 IN FRONT ) IN TOP 1 IN FLUE 0 IN. F4311ZWIAL FILE 116$4RCf MUM I WTI 510 5 RIGHT 0 IN LEFT 0 IN. REAR 6 IN FRONT M IN TOP I IN FLUE 0 IN EL SIDES RIGHT 1 IN LEFT I IN. REAR ) IN FRON1 3 10. TOP 1 IN FLUE 0 IN From Owg. 210341885 Rev. 0 MODELS BASE A B C D E F G H .1 K ITWX803813 4 1185 (45-7/8)(37.l4) 948 870 (34.1/4) 3/4 HI 152 98) 98 (34/8) 219 (8 88 (3-3/8) 730 (28-3(4) MANE TAG: NOTE: All dimensions are in mm/inches. K 0 C 2005 American Standard All Rights Reserved Model No.(1) 471110(6036131000AA c Electrical Data V/Ph/Hz(2) 230/1/60 Min Cir Ampacity 24 Max Fuse Size (Amps) 40 Compressor CLIMATUFF - (R) - SCROLL RL Amps - LR Amps 16.7 - 82 Outdoor Fan FL Amps 2.8 Fan HP - 1/3 Fan Dia (inches) 27.6 ' • Coil Spine Fin TM — - r Refrigerant R-410A 8/04-LB/OZ Line Size-(in.) O.D. Gas (3) 3/4 Line Size-(in.) O.D. Liquid (3) 3/8 Dimensions HxWxD (Crated)49.4 X 35.1 X 38.7 Weight-Shipping 305 Weight-Net 258 Start Components NO Sound Enclosure YES Compressor Sump Heat YES A Ci cased accrnenat some fl-semte limey Heat SWOP Egotism' denifieetiod WPM whiCS is based on ARI Standard 210/240. Calcused in accordance with &E.G. Ords use MACH circuit breakers Os' hues 0 Ian from length fla fr.: It SuClbn eo it: max on - Liquid60ft For (Sealer WOKS and Ills refer to *Oars gong ewe Pub. 32 edenolf35 1111(61 FenfiC41) From Dwg.21D152635 Rev. 11 A-weighted Sound Power Level [dINA)] 4TWX6036-SQ-101.01 SUBMITTAL 3 Ton Split System Heat Pump —1 Phase 4TWX6036B Outdoor Unit ea 4TWX6036131000A General Data SOUND POWER A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB 08(A)] MODEL LEVEL [dB(A)] 63 125 250 500 1000 2000 4000 8000 41 71 42.3 522 54.2 65.1 62.5 57.5 51.7 48.7 US Dane Aousinessor Amerdean Siandart Companles www.trnn.com Mechanical Specification Options General The 4TWX6 is fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 °F. Coding capacities are matched with a wide selection of air handlers and furnace coils that are ARI certified. The unit is UL listed. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, 090 galvanized steal and painted with a weather - resistant powder paint on all louvered panels, prepaint on all other panels. Corrosion and weather- proof CMBP -G30 DuraTuffVM base. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The Climate* compressor features a 10 year limited warranty, internal over temperature and pressure protection and total dipped hermetic motor. Other features include: roto lock suction and discharge refrigerant connections, centrifugal oil pump and tow vibration and noise. US Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels and has a 10 year limited warranty. Low Ambient Cooling As manufactured, this unit has a cooling capability to 55 °F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. Accessories Thermostats — Coding only and heaUcooling (manual and automatic changeover). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. Trene has a polity 0/ continuous product and product data improvement and it reserves the rght to change design and speci //capons without notice. 4/05 A.R.I. Standard Capacity Rating Conditions A.R.I. STANDARD 210/240 RATING CONDMONS — (A) Cooling 80 °F. D.B., 87°F. W.B. air entering indoor coil, 95 °F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43 °F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B., 15 °F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. A.R.I. STANDARD 270 RATING CONDITIONS — (Noise rating numbers are determined with the unit in cooling operation.) Standard Noise Rating number is at 95 °F. outdoor air. vui COOLING SENSIBLE, HEATING COIL. CAPACITY KW SEER EER CAPAC 'F COP 4TXCB031AS3 +'D0060R9V3 26200 3.13 15.25 11 3040( 3 3.3 4TXCB031AS3 +D080R9V3 'D 25400 3.05 15.5 11.2 2980( 3 3.3 4TXCB031AS3 +•0Y080R9V3 AAAAmAel So 3.12 15. 2980( In N N N M b N In V t0 N co 01 co o co op o o o co co o o W W W W W W W W W W W W <71 ..... A A IJ W W W 3.14. 1. 30400 4TXCB031AS3 +•00060R9V3 3.14 15. 3040( 4TXCB031AS3 +•UD080R9V3 3.2 1. 3060( 4TXCB031AS3 +'UD100R9V3 3.11 1, 3100C 4TX03031AS3 +•UY060R9V3 2.91 15 29600 4TXCB036AC3 +•DD060R9V3 2.89 15 29400 4TXC8036AC3 +'bD080R9V3 2.96 15. 3000C 4TXCB036AC3 +•DY060R9V3 3.04 1 30200 4TXC8036AC3 +1DY080R9V3 2.98 15. 3000C 4TXCB036AC3 +'U0060R9V3 2.91 15 2940C 4TXCB036AC3 +'UD080R9V3 2.86 15. 2940C 4TXCB036AC3 +1.1D080R9V4 4TXCB036AC3 + *UD100R9V3 A A “ N tWJ W m W t o VWi W to to A A 888 §Rg8g8 § §8gg8I8 § §§ 24400 2 98 15. }Qa{}Qa{�p`Qjap� `�Q3(g pp�pg�� ����� ��� M C7 N M M f�7 M C7 O C7 N N N 1 N 1 N N N N N 0 5, 2.69 2.66 2.64 2.73 2.64 2.61 2.52 2.48 2.58 2.63 2.57 2.51 2.48 2.59 2.6 2.53 2.55 2.5 2.6 2.65 mMh h h r mm i0 M M V V u V O V m to N i 00 CO a0 co m W 00 00 CO 0 0 00 00 M CO m ei co a0 00 m CO m W a0 co .. O O O O M M M M V Y V p M m V Q V M Q y * n . . . . . . . . . . . . . . . . . . . . . . . M M M M M M M M M M M M M M M M M M M M M M M M M M i 4TXCB036AC3 +'UY060R9V3 24200 2.98 15. 4TXC8036AC3 + *UY080R9V3 23800 2.91 15 4TXCB036AS3 +110060R9V3 27000 3.11 1' 11.4 4TXCB036AS3 +•DD080R9V3 26000 3.04 1' 11.5 4TX03036AS3 +•DY060R9V3 25400 3.05 1' 11.4 4TXCB036AS3 +•DY080R9V3 25800 3.11 15 4TXCB036AS3 +'UDO60R9V3 26800 3.14 15 4TXC8036AS3 +•UD080R9V3 26800 3.12 15.75 11.3 4TXCB036AS3 +'UD100R9V3 27200 3.2 15 4TXCB036AS3 +•UY060R9V3 25400 3.05 15.75 11.4 4TXCB036AS3 +•UY080R9V3 25000 3.01 1' 11.5 4TXC6042AC3 +•00060R9V3 24000 2.93 15.25 11.4 4TXC8042AC3 + *00080R9V3 23200 2.87 15.25 11.5 4TXCB042AC3 +•DY060R9V3 1090 24200 2.96 15 11.3 4TXCB042AC3 +•DY080R9V3 1100 24200 3.02 14.75 11 47 RA49AC3+•Uu060R9V3 1080 24200 2.98 15 11.2 41XCB042AC3 +•UD080R9V3 1010 23400 2.91 1525 11.4 4TXCB042AC3 +1U0080R9V4 1030 23800 2.85 15.5 11.7 4TXCB042AC3 +•UD100R9V3 1100 24200 2.98 15 11.2 4TXCB042AC3 +•UY060R9V3 1080 24000 2.96 15 11.2 4TXCB042AC3 +•UY080R9V3 1030 23600 2.91 15.25 11.4 4TXCB048AC3 +•0D060R9V3 1050 24600 2.92 15.75 11.7 4TXCB048AC3 +10D080R9V3 1000 • 24000 2.91 15.75 11.7 4TXCB048AC3 +•DY060R9V3 1090 24800 2.97 15.5 11.5 4TXCB048AC3 +•DY080R9V3 1100 24800 3.03 15.25 11.3 4TXCB048AC3 +11D060R9V3 1080 34200 24800 2.97 15.5 11.5 30200 2.61 8.5 3.4 4TXCB048AC3 +•U0080R9V3 1010 34000 24000 2.93 15.5 11.6 29600 2.54 8.5 3.4 4TXCB048AC3 +100080R9V4 1030 34200 24400 2.87 15.75 11.9 29600 2.49 8.6 3.5 4TXCB048AC3 +•UD100R9V3 1100 34200 24800 3 15.5 11.4 30200 2.61 8.5 3.4 4TXC8048AC3 +'UY060R9V3 1080 34200 24800 3 15 25 11.4 30200 2.62 8.5 3.4 4TXCB048AC3 +'UY080R9V3 1030 34000 24200 2.93 15.5 11.6 29800 2.55 8.5 3.4 4TXCCO37AC3 +'DY100R9V4 1050 34000 24000 2.93 15.5 11.6 29600 2.54 8.5 3.4 4TWX6036B1 000AA OUTDOOR UNIT WITH AIR HANDLERS COIL 4TEE3F37A1 4TEE3F40A1m 4TFE3F2581 CFM COOLING CAPACITY ENSIBLE APACITY 25800 27200 23600 KW 3.02 2.99 3.09 SEER 16 17 14.5 EER 11.4 12.3 11 HEATING CAPACITY 3220C 3320( 3060( KW 'F 8.8 9.2 8.3 COP 3.4 4.1 3.3 I WIT WITLI CI AC AN D HEAT PUMP COILS ,, - V vV V COOLING SENSIBLE HEATING COIL CFM CAPACITY CAPACITY KW SEER EER CAPACITY KW HSPF COP 4TXCCO37AC3 +'UY100R9V 1050 34000 24000 2.88 15.75 11.8 29600 2.51 8.5 3.5 4TXCCO37AS3 + *3D100R9V5 1180 35600 26800 2.97 16.5 12 30400 2.62 8.8 3.4 4TXCCO37AS3 +'DY100R9V4 1050 341300 25400 3 16 11.6 30000 2.62 8.7 3.4 4TXCCO37AS3 + 1180 35400 26600 3 16.25 11.8 30400 2.62 8.8 3.4 4TXCCO37AS3 +11D100R9V5 1210 Npc� W W W W W W W W W pp W 88888888888088 }}QQ§ 8 88 8 8(S 88�'j Q 8 8 }888Q8 (y ( N N N N N N N N fV N N N fV fV N 3.02 16.25 11.8 30600 2.64 CO P V to 0) 41 V to V 0 co R to to �������� - CO CI CO I CO ht. O CO CO f ( 7 lh Oi 07 07 CO P) 2.97 16.25 11.7 29800 2.57 4TXCCO37AS3 + *UY100R9V4 1050 2.91 15.25 11.4 29200 2.53 4TXCC043AC3 + *DY100R9V 1050 2.88 15.5 11.6 2920 4TXFH033AS3 +"DD060R9V3 1040 2.86 15.5 11.6 29000 2.48 4TXFH033AS3 +`DD080R9V3 1000 2.93 15.5 11.4 29400 2.55 4TXFH033AS3 +•DY060R9V3 1070 2.98 15.25 11.2 29800 2.61 4TXF11033AS3 + *DY080R9V3 1110 2.93 15.5 11.4 29200 2.52 4TXFH033AS3 + *DY100R9V4 1050 2.96 15.25 11.3 29400 2.56 4TXFH033AS3 +11D060R9V3 1070 2.89 15.5 11.5 2900 4TXFH033AS3 + *U0080R9V3 1020 2.85 15.75 11.8 29000 2.46 4TXFH033AS3 +1U0080R9V 1030 2.96 15.25 11.3 29600 2.57 4TXFH033AS3 +11D100R9V 1090 2.96 15.25 11.3 29400 2.56 4TXFH033AS3 + *UY060R9V3 1070 2.9 15.5 11.5 2920 4TXFH033AS3 +11JY080R9V 1030 2.87 15.75 11.9 2960 4TXFH041AS3 +`DDOSOR9V3 1030 4TXFH041AS3 +13D080R9V3 1010 �gp Ngp�88 p t�gppg g g t N N N N N N N N N N N N N N N N N N N N N N N N N N N N N 2.87 15.75 11.9 2960 t ul u u, c c ! u l c c ! ^: cc! r m P I CD I ° I WIC1Ct al W CD CO CCCD mC CDC, CG CCC co COm cocococo cocci W mC CD cC CO C 0 CL1 W m co W w W W W W W W W W W W w W w W W W W W W W W W W W W W W W [n c7)ANA ANAAAAAA AA W A W A A W N AAtl) A A cn 2.94 15.75 11.7 30000 2.56 4TXFH041AS3 +`DY060R9V3 1070 2.99 15.5 11.5 30400 2.63 4TXFH041AS3 +•DY080R9V3 1110 2.94 15.75 11.7 30000 2.56 .4TXFH041AS3 +11Y100R9V 1060 2.94 15.75 11.7 30000 2.56 4TXFH041AS3 +1U1)060R9V3 1070 2.9 15.75 11.8 29600 2.51 4TXFH041AS3 + *UD080R9V3 1020 2.84 16 12.1 29600 2.47 4TXFH041AS3 + UD080R9V4 1030 2.94 15.5 11.7 30000 2.56 4TXFH041AS3 +'UD100R9V3 1090 2.95 15.5 11.6 3000 41XFH041AS3 +1UY060R9V3 1060 2.9 15.75 11.8 2980 4TXFH041AS3+11Y080R9V3 1030 3.13 15.25 11 32600 2.88 TDD060R9V3 +RXCO31S3 3.11 16 11.4 32800 2.84 TDD060R9V3 +RXCO3683 1220 3.06 15.5 11.1 32400 2.83 1D0060R9V3 +1XCO36C4+4AY110V 3.1 15.5 11.1 3280 TDD060R9V3 +TXC042C4+4AYTXV 3.1 15.75 11.3 3280 TD0060R9V3 +TX0048C4+4AYTXV 3.06 15.5 11.1 3240 TD0060R9V3 +TXH033A4+4AYTXV 3.07 16 11.4 moo 2.81 TD0060R9V3 +TXH041A4+4AYTXV 3.05 15.5 11.2 3240 TOD080R9V3 +RXCO3163 3.04 16 11.5 32600 2.79 TDD080R9V3 +RXCO3683 1130 3.02 15.5 11.2 3220 TD0080R9V3 +TXCO36c4+4AY1XV 3.04 15.5 11.2 3240 T00080R9V3 +TXC042C4+4AYTXV 3.04 15.75 11.4 3260 TDD080R9V3 +TXC048C4+4AYTXV 3.02 15.5 11.2 32200 2.81 1D0080R9V3 +TXH033A4 +4AYTXV 3.03 15.75 11.5 3240 TDD080R9V3 +TXH041A4 +4AYTXV 2.97 16.5 12 3240 TDD100R9V5+RXCO3733 1180 3 15.75 11.4 32200 2.76 TDD100R9VS+TXCO37C4+4AYTXV 2.98 16 11.6 32400 2.76 TDD100R9V5 +TXC043C4+4AYTXV _ 1180 2.99 16.25 11.7 32400 2.74 TDD100R9V5 +TXC049C4+4AYTXVH -3 1180 2.97 16 11.5 32000 2.74 TDD100R9V5+TXH033A4 +4AYTXVH -3 1180 2.98 16.25 11.8 32200 2.71 T00100R9V5 +TXH041A4 +4AYTXVH -3 1180 2.93 16.5 12 32400 2.73 TDD120R9V5 +TXCO50C4 +4AYTXVH -3 1190 TDD120R9V5 +TXH033A4 +4AYTXVH -3 1190 34400 26200 2.97 16 11.6 32000 2.73 8.8 3.4 T00120R9V5 +TXH041A4 +4AYTXVH - 3 1190 35200 26800 2.93 16.5 12 32200 2.7 8.9 3.5 TDY060R9V3 +RXCO36S3 1090 34800 25400 3.05 16 11.4 32600 2.81 8.8 3.4 TDY080R9V3 +RXCO31S3 1090 34000 24800 3.12 15.25 10.9 32400 2.86 8.7 3.3 TDY080R9V3 +RXCO3653 1100 34800 25800 3.11 15.5 11.2 32600 2.84 8.8 3.4 4TWX6036B1000AA EAT PUMP COILS 4TWX6036B1000AA HEAT PUMP COILS COOLING SENSIBLE HEATING COIL CFM CAPACITY CAPACITY KW SEER EER CAPACITY KW HSPF COP TDY080R9V3 +TXCO36C4 +4AYTXVH - 1110 33600 24600 3.08 15 10.9 32400 2.86 8.6 3.3 TDY080R9V3 +TXC042C4 +4AYTXVH - 1100 33800 24600 3.1 15.25 10.9 32600 2.88 8.6 3.3 TDY080R9V3 +TXC048C4 +4AYTXVH -3 1100 34200 25000 3 08 15.5 11.1 32800 2.88 8.7 3.3 TDY080R9V3 +TXH033A4 +4AYTXVI 25200 3.08 15.25 10.9 32201 6 3.3 TDY100R9V4 +RXCO37S3 1050 34800 25400 3 16 11.6 32401 8 3.4 TDY100R9V4 +TXH033A4 +4AYTXVI 24400 2.98 15.5 11.2 31801 7 3.4 TDY100R9V4 +TXH041A4+4AYTXVI 25200 2.99 15.75 11.5 32201 8 3.4 TDY120R9V5 +TXCO50C4+4AYTXVI ♦ A W NN r � A 5 � A N �A' r �A' t''' A� A A' A' A fWlN A A' 5 Ja�' W A N �' W� W A' OO §Zi 25 25 25 25 25 8 25 2 §n §g Z5 g§§§ 53 g (NN88A�( �i �� NNNRA ('4 N N N N N N N 2.98 16 11.6 32401 C D OO C OI f Cl i W I C O� W O O o co G W� GO C D GO CD GO GO Co CD OD 00 Co CD GO i W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W N A N A A N A W A W W A W A W W W W A W A A A 2.99 15.75 11.3 31801 TDY120R9V5 +TXH033A4+4AYTXVI 2.98 16 11.6 32201 TDY120R9V5 +TXHO41A4+4AYTXVI 3.14 15 10.9 32801 TUD060R9V3 +RXCO31S3 1190 3.14 15.5 11.2 33001 TUD060R9V3 +RXCO36S3 1200 3.12 15.25 10.9 _ 32801 TUD060R9V3 +TXCO36C4+4AYTXVI 3.14 15 10.9 33001 TUDO60R9V3 +TXC042C4+4AYTXVI TUD060R9V3 +TXC048C4+4AYTXVI 3.14 15.5 11.1 33201 3.12 15.25 10.9 32601 TUDO60R9V3 +TXH033A4+4AYTXVI 3.11 15.5 11.2 32801 TUD060R9V3 +TXH041A4+4AYTXVI 3.14 15.25 10.9 32801 TUD080R9V3 +RXCO3153 1190 3.12 15.75 11.3 33001 TUD080R9V3+RXCO36S3 1200 3.09 15.25 11 32601 TUD080R9V3 +TXCO36C4+4AYTXVI 3.11 15.25 11 32801 TUD080R9V3 +TXC042C4+4AYTXVI 3.11 15.5 11.2 32801 TUD080R9V3 +TXC048C4+4AYTXV TUD080R9V3 +TXH033A4+4AYTXVI 3.09 15.5 11 32401 3.08 15.75 11.3 32601 TUD080R9V3 +TXH041A4+4AYTXVI 3 16.25 11.8 32601 TUDO80R9V4 +RXCO37S3 1180 3 15.75 11.4 32201 TUD080R9V4 +TXCO37C4+4AYTXVI 3.01 16 11.5 32401 TUD080R9V4 +TXC043C4+4AYTXVI 2.99 16.25 11.7 32601 TUD080R9V4 +TXC049C4+4AYTXVI 3 16 11.4 32001 TUD080R9V4 +TXHO33A4+4AYTXVI TUD080R9V4 +TXH041A4+4AYTXVI 2.97 16.25 11.8 32401 3.2 15 10.7 33001 TUD100R9V3 +RXCO31S3 1240 3.2 15.5 11 33201 TUD100R9V3 +RXCO36S3 1250 3.18 15 10.7 32801 TUD100R9V3 +TXCO36C4+4AYTXVI 3.2 15 10.7 33001 TUD100R9V3 +TXC042C4+4AYTXVI 3.19 15 25 10.9 33201 TUD100R9V3 +TXC048C4+4AYTXVI TUD100R9V3 +TXH033A4+4AYTXVI -3 1240 3.18 15.25 10.7 32600 WWPWW m V t0 -I W W W W W W AANW<a TUD100R9V3 +TXH041A4+4AYTXVH -3 1230 3.14 15.5 11.1 32801 3.02 16.25 11.8 32600 TUD100R9V5+RXCO37S3 1210 TUD100R9V5+TXCO37C4+4AYTXVH -3 1210 3 15.75 11.4 32401 3.01 16 11.5 32401 TUD100R9V5+TXC043C4+4AYTXVH -3 1210 TUD100R9V5+TXC049C4+4AYTXVH -3 1210 35200 26400 3.01 16.25 11.7 32601 OCGCGC7CO aO CD oO ap CD a o W a D a D - t V CO N st LO 1' O mt et Y a V N' r o lei l'7 6 ri f7 Pi l7 of ei of 0 C7 4 TUD100R9V5 +TXH033A4+4AYTXVH -3 1210 34200 26400 3 16 11.4 32201 TUD100R9V5 +TXH041A4+4AYTXVH 1210 35200 26800 3.01 16.25 11.7 32401 TUD120R9V5+TXCO50C4+4AYTXVH -3 1210 35200 26400 2.98 16.25 11.8 32401 TUD120R9V5 +TXH033A4 +4AYTXVH -3 1210 34400 26400 2.99 16 11.5 32001 TUD120R9V5 +TXH041A4 +4AYTXVH -3 1210 35200 26800 2.98 16.25 11.8 32201 TUY060R9V3 +RXCO3663 1080 34800 25400 3.05 15.75 11.4 32401 TUY080R9V3 +RXCO36S3 1030 34600 25000 3.01 16 11.5 32401 TUY080R9V3 +TXCO36C4 +4AYTXVH - 1030 33400 23800 2.98 15.5 11.2 32001 TUY080R9V3 +TXC042C4 +4AYTXVH - 1030 33600 23800 3 15.5 11.2 32201 TUY080R9V3 +TXC048C4 +4AYTXVH -3 1030 34200 24200 3 15.75 11.4 32400 2.79 TUY080R9V3 +TXH033A4 +4AYTXVH -3 1030 33400 24400 2.98 15.5 11.2 31800 2.76 TUY080R9V3 +TXH041A4 +4AYTXVH - 3 1030 34400 24800 2.99 15.75 11.5 32000 2.74 TUY100R9V4 +RXCO37S3 1050 34800 25400 2.97 16.25 11.7 32200 2.73 TUY100R9V4 +TXCO37C4 +4AYTXVH -3 1050 33600 24200 2.97 15.5 11.3 32000 2.77 8.7 3.4 4TWX6036B1000AA HEAT PUMP COILS 4TWX6036B1000AA P COILS COOLING SENSIBLE HEATING COIL CFM CAPACITY CAPACITY KW SEER EER CAPACITY KW HSPF COP TUY100R9V4 +TXC043C4 +4AYTXVH -3 1050 34000 24400 2.98 15.75 11.4 32000 2.76 8.7 3.4 TUY100R9V4 +TXC049C4 +4AYTXVH -3 1050 34400 24800 2.97 16 11.6 32200 2.74 8.8 3.4 TUY100R9V4 +TXH033A4+4AYTXVH -3 1050 33600 24600 2.97 15.75 11.3 31800 2.74 8.7 3.4 TUY100R9V4 +TXH041A4+4AYTXVH -3 1050 34400 25200 2.97 16 11.6 32000 2.73 8.8 3.4 TUY120R9V5+TXCO50C4 +4AYTXVH -3 1070 34600 25000 2.98 16 11.6 32200 2.74 8.8 3.4 TUY120R9V5 +TXH033A4+4AYTXVH -3 1070 33800 25000 2.96 15.75 11.4 31800 2.74 8.7 3.4 TUY120R9V5 +TXH041A4+4AYTXVH -3 1070 34600 25200 - 2.96 16 11.7 32000 2.71 8.8 3.5 4TWX6036B1000AA P COILS 04 -05 -2007 JIM LEAIR 101 23 ST SE B/2 PUYALLUP WA 98372 RE: Permit No. M06 -250 14075 35 AV S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 05/12/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this smatter. Sincerely, er Marshall, Permit Technician xc: Permit File No. M06 -250 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206 -431 -3665 License Information License NORTHCC990P4 Licensee Name NORTHWEST CLIMATE CONTROLS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602151177 Ind. Ins. Account Id VICE PRESIDENT Business Type CORPORATION Address 1 101 23RD STREET STE B2 Address 2 City PUYALLUP County PIERCE State WA Zip 983724156 Phone Status ACTIVE Specialty 1 AIR CONDITIONING Specialty 2 SHEET METAL Effective Date 12/18/2001 Expiration Date 12/18/2007 Suspend Date Separation Date Parent Company Previous License NORTHCC994BE Next License Associated License Business Owner Information Name Role Effective Date Expiration Date LAWBER, STEVE PRESIDENT 12/18/2001 LAWBER, CHRIS VICE PRESIDENT 12/18/2001 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 b Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond 143 Bond Company Name FEDERATED MUTUAL INS CO Bond Account Number 9900545 Effective Date 10/03/2006 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount $6,000.00 Received Date 09/13/2006 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= NORTHCC990P4 11/13/2006