Permit M06-272 - WESTFIELD SOUTHCENTER MALL - PARKING GARAGE A
WESTFIELD PARKING GARAGE "A" 633 SOUTHCENTER MALL EXPIRED 5 -26 -07 M06 -272 Parcel No.: Address: Suite No: Tenant: Name: Address: DESCRIPTION OF WORK: INSTALL (1) HEAT PUMP Value of Mechanical: $4,430.00 Type of Fire Protection: doe: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2623049023 633 SOUTHCENTER MALL TUHW WESTFIELD PARKING GARAGE A 633 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD CORPORATION LLC Address: 11601 WILSHIRE BL , LOS ANGELES CA Contact Person: Name: PEGGY PEEL Address: 4600 S 134 PL , SEATTLE WA Contractor: Name: HOLADAY PARKS, INC. Address: PO BOX 69208 , SEATTLE, WA Contractor License No: HOLADPI379NO Furnace: <100X BTU > 100% BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System. Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT ZOUI Fees Collected: MENT TYPE AND OUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 248 -8747 Phone: 206 248 -9700 Expiration Date: 09/03/2007 Steven M. Mullet, Mayor Steve Lancaster, Director M06 -272 11/27/2006 05/26/2007 International Mechanical Code Edition: 2003 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 HP /500,000 BTU 0 15 HP /1,000,000 SW 0 30 HP /1,780,000 BTU 0 80+ HP/1,780,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 $211.95 M06-272 Printed: 11-27-2006 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Print Name: cl in. i t [1, h Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: MO6 -272 Issue Date: 11/27 /2006 Permit Expires On: 05/26/2007 permit and know the same to be true and correct. All provisions of law and ordinances r specified herein or not. Date: it I ni„p t doe: not pre ume to give authority to violate or cancel the provisions of any other state or local laws regulating c of wo I ant authorized to sign and obtain this mechanical permit. Date: 1/ 7 -4E , This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M06 -272 Printed: 11 -27 -2006 Parcel No.: 2823049023 Address: Suite No: Tenant: doe: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 633 SOUTHCENTER MALL TUKW WESTFIELD PARKING GARAGE A 1: ** *BUILDING DEPARTMENT CONDrnoNS * ** PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: M06 -272 ISSUED 11/17/2006 11/27/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 7: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248 - 6630). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. M06 -272 Printed: 11 -27 -2006 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: I I r afp M06 -272 Printed: 11 -27 -2006 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httml/www.citukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted hrough the mail or by fax. * *Please Pnnt ** SITE LOCATION t King Co Assessor's Tax No.: SS? 70 o — O Z 7 7 Site Address: 0.3. So (-Pla Met)) Suite Number: sc Tenant Name:. G '' //tt eARAOtP ' e n9 Property Owners Na W e s ti P Id Pt Corp/n-(31/c) n a Mailing Address: 0 S • ,3a S ¢st t e_ City Name: 70, y q , Pee. Mailing Address: (es O S . / 3 ' p' E -Mail Address: r ° J9 ypQA0 /adct y parKs. O. 0.) rvt Company Name: No L ff b A ( PAR Ks, .4" NC • Mailing Address: 44 00 S . /3 4 PkQ Spot* be City Day Telephone: Contact Person: '-- Pe.? q ✓/ II Pe e/ E - Mail Address: p #. �? ye( A n tad ayfmr KC ('.Anti Contractor Registration Number: At O PT 3 79/4 Contact Person: E -Mail Address: Contact Person: E -Mail Address: QMpplicatiomsV'osms- Applications On LineV -2006 - Permit Application doc Revised: 4 -2006 bh W TUN WI LA W Building Permit No. W1 M, —21 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. h n Project No. PO4' — O- (For office use only) New Tenant: Day Telephone: Jemtt) Fax Number: Expiration Date: IA) A- State Floor: NY ❑ ..No 9 2/49 Zip CONTACT PERSON . o4-4Y9 GOA 9g/1g City Fax Number: a0 6 -� 7 g - 874 State Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) ) k0/r 99769 State Zip e?o 6 13'9- 0 r17 ? 0 6 • _Pit - 17 76 I ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: State state Zip City Day Telephone: Fax Number: ENGINEER OF RECORD - AU plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Zip Page I of 6 Unit Type: Qtv Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>IOOK BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP/I ,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Command Other Mechanical Equipment MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION 176LKp4r pA IMS 2A/c. l40 S. /3$t ,O/ Company Name: Mailing Address: Contact Person: (9'_Q -C 12.- /� E -Mail Address: p C nrio (a) if oled4.yrarAS co wt. Contractor Registration Number: f/aL R DPI 3 7 T A'O Valuation of Project (contractor's bid price): $ Vi-30• 09 Scope of Work (please provide detailed information): Use Residential: Commercial: Fuel Type: Electric Indicate type of mechanical work being installed and the quantity below: rne S a'Ettt2 t EVA- 9g /4 City State Zip Day Telephone: ..16 6 (n -..24 / Q - e 717 Fax Number: 26 - -9700 Expiration Date: 9/0 3/0 7 New .... ❑ Replacement Replacement ©� Gas....❑ Other: 1-ca t Patio I Q:Upplications Forms-Applications On Line 3 -2006 - Pemnit APPlkntion dec Revised: 4-2006 bh Page 4 of 6 • Noti PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 1053.2 International Building Code (current edition). Plumbine Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: � • Print Name: 1) -e_ 0000 ^e. Mailing Address: - o S . /341 I Date Application Accepted: Q:UpplicaliuwFOrms- Applications On Linc`3 -2006 - Prnnil Appliceoon Jac Revised: 4 -2006 6h Day Telephone: � d S 2 92 8 7 5'7 Date Application Expires: `� Date: 7 / / /(p, 4' Staff Initials: Zip Page 6 of 6 !Mr: RECSES -OA RECEIPT NO: R06-01881 Initials: JEM User ID: 1166 Payee: HOLADAY- PARKS, INC. SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431 -3665 Web site: http: //www.cLtukvilawa.us SET RECEIPT Payment Date: 11/27/2006 Total Payment: 353.90 SET ID: 1127 SET NAME: HOLADAY -PARES M06 -272 9 175.56 M06 -273 178.34 TOTAL: 175.56 TRANSACTION LIST: Type Method Description Amount Payment Check 157200 353.90 TOTAL: 353.90 MECHANICAL - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000/322.100 351.12 000/345.830 2.78 TOTAL: 353.90 209? 11/2? i ?7 16 TOTAL 353.90 Doe: RECSEIS -05 RECEIPT NO: R06 -01853 Initials: JEM User ID: 1165 Payee: HOLADAY PARKS, INC. SUED: 5000000625 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount M06 -272 36.39 M06 -273 33.61 TOTAL: 36.39 TRANSACTION LIST: Type Method Description Amount Payment Cash 70.00 TOTAL: 70.00 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/hnvw.dh4wilawa.us SET RECEIPT Payment Date: 11/17/2006 Total Payment: 70.00 Account Code Current Pmts 000/345.830 TOTAL: 70.00 70.00 1.923 11/20 9716 TOTAL 70.00 04 -05 -2007 PEGGY PEEL 4600 S 134 PL SEATTLE WA 98168 RE: Permit No. M06 -272 633 SOUTHCENTER MALL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 05/26/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall, Permit Technician xc: Permit File No. M06 -272 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: MO6 -272 DATE: 11 -17 -06 PROJECT NAME: WESTFIELD PARKING GARAGE A SITE ADDRESS: 633 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Mi II - f Building Division Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Documentstrouting slip.doc 2 -28-02 PERMIT COORD COP& PLAN REVIEW /ROUTING SLIP Fire Preventio I Structural Incomplete ❑ Planning Division ❑ Permit Coordinator ❑ DUE DATE: 11 -21-06 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESfTHURS ROU ING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 12-19 -06 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License HOLADPI379NO Licensee Name HOLADAY PARKS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 578004089 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 69208 Address 2 City SEATTLE County KING State WA Zip 98188 Phone 2062489700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/21/1983 Expiration Date 9/3/2007 Suspend Date Separation Date Parent Company Previous License HOLADPF376NO Next License Associated License Business Owner Information Name Role Effective Date Expiration Date PARKS, GERALD TJR 01/01/1980 PARKS, DAVID L 01/01/1980 TALBOT, PAUL 01/01/1980 NELSON, MICHAEL 01/01/1980 BECK, DAVE 01/01/1980 OCONNOR, BONNY K 01/01/1980 NAILON, JUNE A 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information https: // fortress. wa. gov /lni/bbip /printer.aspx ?License HOLADPI379NO 11/27/2006 BASIS OF DESIGN DESIGN CRITERIA CRITERIA SOURCE 1 2003 INTERNATIONAL BUILDING CODE EFFECTIVE AUGUST 15. 2004 2 2003 INTERNATIONAL MECHMMCA. CODE EFFECTIVE AUGUST 15. 2004 3 2003 WSEC (CHAPTER 51 -11 WIC) EFFECTIVE AUGUST 15. 2004 5 OSA DESIGN TEMP = 83'F DB, 67'F TM 6 ISA DESIGN TEMP = 50'F HFAING, 80T COOLING 7 EQU F ENT LOAD = 36 MBH PER PROPOSAL. t GENERAL NOTES 1. ALL TRADES TO LEAVE 36' CLEARANCE N FRONT CF MECHAMCN. EQUIPMENT ACCESS PANELS FOR SERVICING. 2. CUTTING, FRNIING, PATCHING AND PANNING OF WALL, CEILING AND FLOOR OPEitNNGS SHALL BE BY GENERAL CONTRACTOR. 3. FINAL PAINTING OF GRILLES, REGISTERS, AND DIFFUSERS, AS MAY BE REQUIRED BY ARCHITECT, SHALL BE DONE BY GENERAL CONTRACTOR. 4. (FERAL CONTRACTOR IS RESPONSIBLE FOR TEMPORARY HEAT DUIfNG CONSTRUCTION. 5. UNIT WEIGHTS AND LOCATIONS HAVE BEEN COORDINATED MTHH ARCHITECT AND STRUCTURAL ENGINEER TO DETERMINE BUILDING STRUCTURAL ADEQUACY. F IT IS NECESSARY TO RELOCATE A UHT, NOTIFY HOLADAY- PARKS' ENGINEERING DEPARTMENT FOR RE- COORDINATION. 6. IN NO INSTANCE SHALL OTHER TRADES HANG OR SUPPORT EQUIPMENT, CEILING ORES, LIGHT FIXTURE HANGERS, ETC., FROM HVAC EQULPIIENT OR DUCTWORK 7. PLUMBER SHALL ROUTE PLUMBING VENTS SO AS TO MAINTAIN VINM M 15 FEET OF CLEARANCE FROM OUTSIDE NR INTAKES. ELECTRICAL COORDINATION NOTES 1. WHERE NDICATD ON EQUIPMENT SCHEDULES, THE EQUIPMENT COMES COMPLETE FROM THE FACTORY NTH MOTOR CONTROLS AS REQUIRED. ELECTRICIAN SHAH. PROVIDE SERVICE AND A DISCOMECT PER CODE, AND DO ALL FOYER NRNG,, INCLUDING COMIECTNG TO EQUIPMENT. 2. WHORE INDICATED ON EQUIPMENT SCHEDULES, THE EQUIPMENT REQUIRES FIELD NSM MOTOR STARTERS. ELECTRICAL CONTRACTOR SHALL RIRNSHH AND INSTALL MOTOR STARTERS (OR CONTACTORS WHERE NDHCATED). PROVIDE SERVICE AND DISCONNECT PER CODE, AND 00 ALL POWER WING, NCLUDIG CONNECTING TO EQUIPMENT. HOLDING COIL. CIRCUIT SHALL BE POWERED BY ELECTRICAL CONTRACTOR (120 VOLT/1 PH. UNLESS INDICATED OIHHERTASE). ALL STARTERS SHALL BE PROVIDED WITH II-0--A STITCH. 3. 2 - 120V CONTROL CIRCUITS PER FLOOR ARE REQUIRED. EC. SHALL PROVIDE SERVICE MD A DISCONNECT PER CODE, AND DO ALL POWER SIRING, INCLUDING CONNECTING TO CONTROLS CONTRACTOR PROVIDED TRANSFORMERS AND EQUIPMENT. SEISMIC RESTRAINING NOTES 1. ANY BASE-MOUNTED/SPRING-MOUNTED EQUIPMENT SHALL HAVE TOTALLY ENCLOSED, SEISMIC RATED SPRINGS (MASON MODEL SSLFH OR EQUAL), OR OPEN SPRINGS PLUS SEISMIC 'SNP' (MASON MODEL Z -1225 OR EQUAL). 2. ALL SPRING MOUNTED. SUSPENDED EQUIPMENT SNAIL HAVE SEISMIC CABLES INSTALLED IN ADDITION TO EQUPfENT HANGERS. CABLES SHALL BE INSTALLED DIAGONALLY UP AND AWAY FROM EQUIPMENT COMERS AND BE ATTACHED TO THE STRUCTURE ABOVE. CABLES SHALL BE LEFT PARTIALLY SMACK. SIZE AND INSTALL CABLES PER SMACNA SEISMIC RESTRAINT MAMMA. 3. ANY EQUIPMENT MOUNTED RIGIDLY TO THE BUILDING STRUCTURE SHALL NOT REQUIRE ADDITIONAL SEISMIC RESTRAINT. 4. RESTRAIN ALL RECTANGULAR DUCTS 6 SQ. FT. OF AREA AND LARGER AND ALL ROUND DUCTS 2W N DUME1ER AND LARGER RESTRAINTS SHALL OCCUR 30 FEET 0C. MAXIMUM AND SHINE. BE MAILED AT EVERY DUCT TURN AND AT 1W EID OF THE DUCT RUN. SIZE AND "STALL RESTRAINTS PER SMACNA SEISMIC RESTRAINT MA AL 5. ALL CEI NG MOIM1ID DIFFUSERS SHALL HAVE WIRES (16 GA) ATTACHED TO 111E ABOVE FLOOR SLAB OR STRUCTURE SAFETY WIRES SHALL BE LEFT PARTIALLY SLACK ALTERNATE METHOD SHALL BE TO ATTACH DIFFUSERS TO T-BAR GRID WITH SCREWS, RIVETS, OR CETLLIG CUSPS FOR WAS WEIGHING LESS THAN 20 POUNDS. f SHEET METAL NOTES 1. DUCT SAES MATED ON PUNS NE NET INSIDE DIMENSIONS. A CAL -OUT SUCH AS 1 2' X 12'/SL MEANS A 14' X 14' SHEET METAL DUCT MTH SOUDLiERi, GIVING A NET INSIDE DIMENSION OF 12' X 12'. 2. TH=ROUGH PENETRATION AND UEI18RANE PENETRATION FIRE STOP AS REQUIRED N 111E UMBC SH A L BE PROVIDED AND INSTATED BY DE UMW& CONTRACTOR FIRE STOP SYSTEM SHALL BE 311 BRAND FIRE BARRER CP 25‘13T MUM OR APPROVED EQURVAENT. NOTE PER UBC 714 EXCEP'TIONt FIRE AND COM®UJON FEE AND SMOKE DAMPERS SHALLL BE INSTALLED IN ACCORDANCE WITH DER LOWS. MA* FACTURER NSTM. A1HON INSTRUCTIONS DO NOT REQU RE TIRE STOP BE1WEEN SLEEVE AND ASSEMBLY PENETRATED 3. DUCTWORK SHALL BE CONSTRUCTED TO DIMENSIONS MATED ON PUNS. THE TOLERANCE OF T ESE DIMENSIONS U&L BE AS SFECHFTm N HOIRMY- PARKS, INC. SHOP STANDARDS MIAMHAL LENGTHS, AND CRITICAL DSIEENSIGNS EEIWEDI DUCTWORK AND OILER liRDING/SYSIEM ELEMENTS ARE INDICATED WMEFE A LOCATION OR DiENSION SCALED FROM 111E DRAWING WELL NOT BE ADEQUATE THE TOLERANCE OF CRITICAL DiENSIONS, if NOT tOICAIF9, SHALL DEFAULT TO THAT OF THE INSTADDIG IiEG3ANCS MEASURING DEVICES. SCALD LOCATIONS OR DIMENSIONS ARE NOT SUBAECT TO TOLERANCE GOOELIES` 4. THESE PLANS WAVE BEEN COORDNATED IITH THE A .0 HI1EC1IUR IM, STRUICIURM. DER IND I 1 ELECTRICAL OWINGS. AMNY CHANGES N THIS LAY -OUT MUST BE REVE'ED BY HOLIDAY -PARK ENGKERING DEPARTMENT. f [21 XXX / I ma2 I 12x12/SL w- S.R.G. rf 12x12/11 38x24• U 3 M111111■011110. S.S.G. HVAC LEGEND DUCT UNDER POSITIVE PRESSURE DUCT UNDER NEGATIVE PRESSURE TURNING VANES ELEVATION FROM F.F.L. wz� (INSULATION AND DUCT FLANGES EXTEND p EQUIPMENT IDENTIFICATION THERMOSTAT SENSOR SDEWALL SUPPLY GRILLE DOUBLE DEFLECTION. HORIZONTAL FRONT BLADES T11US MODEL 27281. - KRUEGER MODEL 880H SIDEWALL RETURN GRILLE FIXED 35 DEGREE DEFLECTION BLADES. WITHOUT OBD THUS MODEL 350RL - KRUEGER MODEL 58011 SUPPLY AE ARROW RETURN AIR ARROW SPEED Mat FURNSk® BY HOLIDAY- PARKS, NISTAIED BY ELECTR CONTR. FLEXIBLE CONNECTION DUCT HEATER MAMIAL VOLUME DAMPER MOTORIZED DAMPER BACK DRAFT DAMPER SMOKE DETECTOR VERTICAL FIRE DAMPER (1 Si HOUR) IN AIRSTREAM RUSKIN MODEL 0182 STYLE A • HORIZONTAL FIRE DAMPER (1% HOUR) IN ARSVEAM RUSi4N MODEL DIM STYLE A 3 HR VERNAL FIRE DAMPER (3 HOUR) N AIRSTREAM RUSKIN MODEL 01823 STYLE A 3 III VERTICAL FYI` DAMPER (3 HOUR) IN AI RSIII:JM RUSKIN MODEL 01823 STYLE A BACK DRAFT DAMPER RUSKIN MODEL 802/A1, LOCAL VELOCITY < 1500 FF11 BACK DRAFT DAMPER RUSKIN MODEL BD2/A2, LOCAL VELOCITY < 2500 FPM BACK DRAFT DAMPER RUSKIN MODEL 806, LOCAL VELOCITY < 3500 FPM SMOKE DAMPER HORIZONTAL VERTICAL COMBINATION SMOKE AND FIRE DAMPER VERTICAL COMBINATION SMOKE MIND FIRE DAMPER SPIN-IN TAKE-OW & VOLUME DAMPER WEANS 14' x 14' 0.D! SHEERETAL M1H 1' SOUDLNER (111(0.). 12' x 12' NET ID. MATES UNLINED 12' x 12' S.Y. DUCT INDICATES t2' x 12' LO. OUCIBOARD INDICATES LIMED 12' x 12' S.M. DUCT 111111 IMLATED WRAP RISE OR DROP M DIRECTION OF FLOW HOME DUCT MATES FIAT OVAL DUCT SPN-N TNE-OFF & =ME DAR MAUI RIGID ROHM FIf3ERGUSS DUCT INDICATES AIRFLOW DNECUMM! DOOM rT GARAGE TO THE GARAGE • o: GRILLES, REGISTERS, DIFFUSERS LEGEND S.S.G. SIDEWALL SUPPLY GRLLE DOUBLE DEFLECTION, HORIZONTAL FRONT BLADES TITUS MODEL 27281. - KRUEGER MODEL 88011 SIG. SIDEWALL RETURN GRILLE FIXED 35 DEGREE DEFLECTION BLADES, %M OUT 080 THUS MODEL 350RL - KRUEGER MODEL 580H AFF AP 800 BOU DMPR DN. EA EAT E.C. BEV. ESP FO ABOVE FINISHED FLOOR ACCESS PANEL BACK DRAFT DAMPER BRAKE HORSE POWER BOTTOM OF UNIT CONNECT /COMECTION DAMPER DOWN OFINN EACH ENTERING AR TEMP ELECTRICAL CONTRACTOR ELEVATION EXTERNAL STATIC PRESSURE FIRE DAMPER FFL RMSHED FLOOR LEVEL FIA FULL LOAD AMPS RR. DR. FLOOR DRAIN FOB FLAT ON BOTTOM FOT FLAT ON TOP FLIT FUTURE GC ORAL CONTRACTOR HVAC ABBREVIATIONS HP ID NSUL LAT MCA N/A NC NC NO NOM. NTS OA OD PRIM PSI RA SA SM SP TYP VD W/ HORSE POWER INSIDE DIMENSION/DIAMETER INSULATION LEAVING AIR TEMP MIMMUM CIRCUIT AMPACITY NOT APPLICABLE NORMALLY CLOSED NOT N CONTRACT NORMALLY OPEN NOMINAL NOT TO SCALE OUTSIDE MI OUTSIDE DIMENSION PRIMARY POUNDS PER SQUARE INCH RISE RETURN AIR SUPPLY AR SHEET META. STATIC PRESSURE TYPICAL VOLUME DAMPER MTH LEGAL DESCRIPTION 13 YNTERURRBAN ADD TO SEATRE POR OF SE 3 OF SW Y4 OF SEC 23 -23-04 -- BEG SW COR OF SE Y4 TH N 89 -40-24 W 65.40 FT TN N 00-19-36 E 40 FT TO 1POB TH CONTG N 00 -19 -36 E 110 FT TH N 89 -40-24 W 151.60 FT TN S 00 -19 -36 W 110 FT TH S 89 -40-24 E 151.60 FT TO TPOB 1: 2: 3: 4: 5: COOING CAPACITY IN 11811 AT 80 0/67 vb. 85 F. db OUTDOORS HEATING CAPACITY AT 20' F. OUTDOORS ACCESSORES SCUM ION AMBIENT KIT POWER TIRING AND DISCONNECT PROVIDED AND INSTALUED BY EC. T -STAT SHALL BE PROVIDED AND IMAM D BY CONTROLS CONTRACTOR (M.0 ) • EXPIRED HAY 26 2607 SHEET INDEX REYI SMELL SHEET TIRE 1 M0.01 LEGENDS, NOTES & SCHEDULES 1 1A2.01 FIRST FLOOR HVAC PLAN SCOPE OF WORK 1. INSTAL (1) NEW 3 TON WALL MOUNTED SEW-CONTAINED HEAT PUMP. 2. INSTALL STAND - ALONE TERMOSTAT AS SHOWN. 3. INSTALL TWO (2) WALL SLEEVES, ONE (1) SUPPLY GRILLE~ AND ONE (1) RETURN GIIIlE AS SHHOYHN. 4. START. TEST & ADJUST SYSTEM. SEQUENCE OF OPERATION HEAT PUMP TO OPERATE BAS LO ON STAND -ALONE THERMOSTAT. ALL OTHER EXISTING EQUIPMENT PER BULONG STANDARD. HEAT PUMP SCHEDULE IP AREA SERVED ELEV MACM E RM MAKE BARD MODEL N1361 COO NG (VI TOTAL SEAS. 37.96 27.58 Inc. CAP MBH ciu FAN PERFORMANCE DATA E.S.P. RPM NW 1100 0.3 NA OSA. 0 I HTR KW 5 ELECTRICAL MCA Y/PH 230/1 53 MGT. 380 EEFL 9 COP 2.9 FLIERS Q SIZE 1 16' X 3O REMARKS 1.2,3,4.5 CRAMS NE DAMS dela Imes SEPARATE PERMIT REQUIRED FOR: O Mechanical Vilecblcal QGt6 PT s city of Tukwila BUILDING DIVISION PILEMti, Amu. ANA. • Pion ream Emmet Is subject lo wore Approval d R the Mo ion d code or arcfnarxm. Recerpt appro►ed /9xld feel. x..41. A City of BUILDING DIVLSION 0(19 Pew 2 PENDING CITY APPROVAL MED No changes s h a l l without made � i s o v cf ci orit wi hoist r.y�� Tukwila Building Dive:: a new plan s�;m:;Lat h+p L: R.:r�.ons WI require review fees. r.nd may laclude +" U • I REVIEWED FOR CODE COMPLIAN CE M r)nrA Icn NOV 2 i ZOQS •: () Ci Of Tukwila BUILDING DNMSION APPROVED FOR CONSTRUCTION I RI • 1 i 1 1 1 N O .' • t•1 'I ' it 4 t I:I' : • I TII :! } FIRST FLOOR HVAC PLAN SOUTHCENTER GARAGE A 633 SOUTHCENTER MALL TUKWLA, WA 98188 ...1 .._ . ,..._.. } INA app I • , t 1 I C. ;t I r1 • . 1 i (:r j . (' . Li1 ' 1 ii 1 1 . 1 .• • .. /• 1 I I iS 1.. ,<.., •1 t date: 11/15/06 1/16" • 1' -0" .ngln..Ndt drowns OR r • 0 t 1 1 I 1 I t 1 I I I • • • rfl co oMgMai Job num 4807 I • I I 1 i \, el z 146 rn G) 2 N o � ' tv C 3 rn ,� v cz zit: T ga ;Z m m a N ow; 0 • a 41) HOLADAYNPARKS, INC. 4600 S. 134th Plat. Soothe, WA 98168 P.O. Box 69208 (206) 248 -9700 STATE CONTRACTORS' UCENSE NUMBER: NOI.ADPI379NO • by • • oldemban