Loading...
HomeMy WebLinkAboutPermit M06-273 - WESTFIELD SOUTHCENTER MALL - PARKING GARAGE BWESTFIELD PARKING GARAGE "B" 633 SOUTHCENTER MALL EXPIRED 5 -26 -07 M06 -273 Parcel No.: Address: Suite No: Tenant: Name: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.cttukwila.wa.us 2623049023 633 SOUTRCENTER MALL TUKW WESTFIELD PARKING GARAGE B 633 SOUTHCENTER MALL , TUXWILA WA Owner: Name: WESTFIELD CORPORATION LLC Address: 11601 WILSHIRE BL , LOS ANGELES CA Contact Person: Name: PEGGY PEEL Address: 4600 S 134 PL , SEATTLE WA Contractor: Name: HOLADAY PARKS, INC. Address: PO BOX 69208 , SEATTLE, WA Contractor License No: HOLADPI379NO DESCRIPTION OF WORK: INSTALL (1) HEAT PUMP Value of Mechanical: $4,430.00 Type of Fire Protection: Furnace: <100K BTU > 100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT 0 0 0 0 0 1 0 0 0 0 0 0 0 0 EQUIPMENT TYPE AND QUANTITY Fees Collected: * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 248 -8747 Phone: 206 248 -9700 Expiration Date: 09/03/2007 Steven M. Mullet, Mayor Steve Lancaster, Director M06 -273 11/27 /2006 05/26/2007 International Mechanical Code Edition: 2003 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 HP /500,000 BTU 0 16-30 HP /1,000,000 BTU 0 30 HP /1,750,000 BTU 0 80 +HP /1,780,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment $211.95 dot: IMC -10/06 M06 -273 Printed: 11 -27 -2006 Permit Center Authorized Signature. I hereby certify that I have read an governing this work will be compli The grantin constructio Signature: Print Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: httn: / /www.ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -273 Issue Date: 11/27/2006 Permit Expires On: 05/26/2007 Date: permit and know the same to be true and correct. All provisions of law and ordinances r specified herein or not. permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating pert c: of wor am authorized to sign and obtain this mechanical permit. Date: I I — 1 - 15 -( c= , This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M06 -273 Printed: 11 -27 -2006 Parcel No.: 2623049023 Address: Suite No: Tenant: � b City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 633 SOUTECENTER MALL TURW WESTFIELD PARRING GARAGE B 1: ** *BUILDING DEPARTMENT CONDN7ONS * ** PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: M06 -273 ISSUED 11/17 /2006 11/27/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 7: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248 - 6630). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 M06 -273 Printed: 11 -27 -2006 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction •- t •erforman e of work. Signature: doe: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.cttukwila.wa.us Print Name: 1A-44i C C_ - T `� Date: I 7-6 M06-273 Printed: 11 -27 -2006 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://Www.ci.tukwila.wa.us CONTACT PERSON Name: 24 79 y Pee / Day Telephone: Mailing Address: 40 O S. f 3 ! Sea-al P r1t City E -Mail Address: pony p PJ rl o fa day pa r K' . 0 . D m Fax Number: >Vo TA IC S, Contact Person: Toy Peel E -Mail Address: Pi ( to(adayparkS.CO Contractor Registration Number: AcA 11 PT 3 i9/143 Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:UpplicmionsWorms- AppItcelions On Line\3-200(- Permit Applic,tioadoc Revised: 4 -2006 bit Building Permit No. Mechanical Permit No. mg Q Plumbing/Gas Permit No. Public Works Permit No. Project No. Fb&-e' (For office use only) - - Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted hrough the mail or by fax. * *Please Pent** SITE LOCATION n . r,� King Co Assessor's Tax No.: 3 snf 7 00 - 0 2 4' 7 Site Address: 4 33 go ttitke P�t'P r /Ha I I Suite Number: Floor: Tenant Name: So ukkco K t♦ r ur w e KRh9 N e w Tena nt: ,;, Car Yes ❑.,No Property Owners Name: b)e c t v Id Car arat l p,« Mailing Address: 460 0 S . / A 4 It Pi c7PA ttit City COAL 9 &Ha State Zip -RO/p -44/9-2747 (A IA- 9g /€09' State Zip .a 6 -a18 -8 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) ) Company Name: n Mailing Address 4'400 S. /3 41 pi cSpa'ttl'e I 444-- 2C /62 City Day Telephone: -- ( 0 1 19- g 717 Fax Number: „? O 6 • 71� -� 70 Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record State Zip Page! of 6 1 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace> I00K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /I,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator - Comm/Ind Other Mechanical Equipment Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): -P t_ C / \ ) MECHANICAL PERMIT INFORMATION — 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name /70L // At D AY T T �/stirs _rive . Mailing Address: City State Zip Contact Person: C91Q_M-7 1 -Q- Day Telephone: id (., -� ` Q 71 E -Mail Address: DC a C ol[t a y pet rAt s Co m Fax Number: .7 o !e - „tie Q 70 o Contractor Registration Number: t`/OL A DPI' 3 7'7 A/O Expiration Date: 9/O 3/0 7 Use: Residential: New .... ❑ Replacement....❑ Commercial: New ....Lir Replacement .... ❑ Fuel Type: Electric aj / Gas....❑ Other: )� -a.& 1Ju rttr Indicate type of mechanical work being installed and the quantity below: Q:Upplications\Fonns- Applications On Is :3- - Permit Application.dec Revised: 4-2006 bh Wio. Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: TH `7ve�. Date: J// / 4 c Print Name: 7 e t/ Pee) q q e Arta. Day .' Telephone: e 6 / aT 2 • g 7 1 Mailing Address: 44,470 S S. /34S A , (t) A- 4 ,4149 /// City State Zip I Date Application Accepted: t MIA? Q: Applicatiom6mma- Applications On Line08006 Permit Application.doc Revised: 4-2006 bh Date Application Expires: _ y j 11 4 Staff Initials: / I Page 6 of 6 Doc: RECSETS -OB RECEIPT NO: R06 -01881 Initials: JEM Payment Date: 11/27/2006 UseIID: 1165 Payee: HOLADAY - PARRS, INC. SET ID: 1127 SET NAME: HOLADAY -PARKS SET TRANSACTIONS: Set Member Amount M06 -272 175.56 178.34 TOTAL: 175.56 TRANSACTION LIST: Type Method Description Amount Payment Check 157200 353.90 TOTAL: 353.90 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431 -3665 Web site. http: //www.ci.tukwila.wa.us SET RECEIPT Total Payment: 353.90 Account Code Current Pmts 000/322.100 351.12 000/345.830 2.78 TOTAL: 353.90 2099 11/27 9716 TOTAL 353.90 Doc: RECSEIS -06 RECEIPT NO: R06-01853 Initials: JEM User ID: 1165 Payee: HOLIDAY PARKS, INC. SET ID: S000000625 SET NAME: limp set/Initialized Activities SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: /Amvw.ci.tukwila.wa.us M06 -272 36.39 M06 -273 33.61 TOTAL: 36.39 ACCOUNT ITEM LIST: Description TRANSACTION LIST: Type Method Description Amount Payment Cash 70.00 TOTAL: 70.00 PLAN CHECK - NONRES SET RECEIPT Account Code Current Pmts 000/345.830 TOTAL: Payment Date: 11/17/2006 Total Payment: 70.00 70.00 70.00 n , _. .._ iu ij)friL. 04 -05 -2007 PEGGY PEEL 4600 S 134 PL SEATTLE WA 98168 RE: Permit No. M06 -273 633 SOUTHCENTER MALL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206. 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be In writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 05/26/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall, Permit Technician xc: Permit File No. M06 -273 City of Tukwila Steven M Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 - 3670 • Fax: 206 - 431 - 3665 ACTIVITY NUMBER: M06 -273 DATE: 11 -17 -06 PROJECT NAME: WESTFIELD PARKING GARAGE B SITE ADDRESS: 633 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 0 M1190 Bui i Division Public Works Complete Comments: REVIEWER'S INITIALS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY rnPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Approved with Conditions Q( I/ -2f Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ ❑ Permit Coordinator ❑ Planning Division DUE DATE: 11-21 -06 Not Applicable I 1 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route E Structural Review Required ❑ No further Review Required DATE: DUE DATE: 12-19-06 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License HOLADPI379NO Licensee Name HOLADAY PARKS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 578004089 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 69208 Address 2 City SEATTLE County KING State WA Zip 98188 Phone 2062489700 Status ACTIVE Specialty I GENERAL Specialty 2 UNUSED Effective Date 1/21/1983 Expiration Date 9/3/2007 Suspend Date Separation Date Parent Company Previous License HOLADPF376NO Next License Associated License Business Owner Information Name Role Effective Date Expiration Date PARKS, GERALD T JR 01/01/1980 PARKS, DAVID L 01/01/1980 TALBOT, PAUL 01/01/1980 NELSON, MICHAEL 01/01/1980 BECK, DAVE 01/01/1980 OCONNOR, BONNY K 01/01/1980 NAILON, JUNE A 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perfonn construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= HOLADPI379NO 11/27/2006 HEAT PUMP SCHEDULE HP I AREA SERVED YAKS ` YOWL COOING OWN} 11TG. CAP MBH FAN PERFORMANCE DATA 1 ESA. MR KW r EEEC1TICAL MGT. ER. COP FLIERS REIMS TOTAL SENNS. CFR ESP. RPM RIP V/PH MCA QTY SIZE T, 1 B EV MACHINE RM BARD VM361 37.96 27.58 20.9 1100 0.3 NA - 0 5 230/1 53 380 9 2.9 1 16' X 30' 1, 2, 3, 4, 5 BASIS OF DESIGN DESIGN CRITERIA CRITERIA SOURCE 1 2003 INTERNAL ORN. BUILDING CODE EFFECTIVE AUGUST 15, 2004 2 2003 N1EIOMUONN. TECHAI:AL CODE EFFECTIVE AUGUST 15, 2004 3 2003 WSEC (CHAPTER 51 -11 WAC) EFFECTIVE AUGUST 15. 2004 r 5 OSA DESIGN TEMP = 83'F DB, 67T WS 6 ISA 0E5k8N TEIP = 50'F HEATING, 80T COOLING 7 EQUIPMENT LOAD = 36 TE I PER PROPOSN. • • • GENERAL NOTES 1. AU. TRADES TO LEAVE W CLEARANCE N FRONT OF MECHANICAL EQUIPMENT ACCESS PANELS FOR SERVICING. 2. CUTTING, FRAMING, PATCHING AND PANTING OF WALL. CEUNG AND FLOOR OPENINGS SHALL BE BY GENERAL CONTRACTOR. 3. FINAL PNNiNG OF GRILLES, REGISTERS„ AND DIFFUSERS. AS MAY BE REQUIRED BY ARCHITECT. SHALL BE DONE BY GENERAL CONTRACTOR. 4. GENERAL CONTRACTOR IS RESPONSIBLE FOR TEMPORARY HEAT DURING CONSTRUCTION. 5. UNIT WEIGHTS AND LOCATIONS HAVE BEEN COOROINATED WI1H ARCHITECT AND STRUCTURAL ENGINEER TO DETERMINE BUILDING STRUCTURAL ADEQUACY. F IT IS NECESSARY TO RELOCATE AUNT. NOTIFY HOLIDAY- PARKS' ENGII€EHING DEPARTMENT FOR RE-COORDINATION. 6. IN NO INSTANCE SHAD. OTHER TRADES HANG OR SUPPORT EQUIPMENT. CEUNG WIRES, UGHT FIXTURE HANGERS, ETC., FROM HVAC EQUIPMENT OR DUCTWORK 7. PLUMBER SHALL ROUTE PLUMBING VENTS SO AS TO MAINTAIN MNMUR 15 FEET OF CLEARANCE FROM OUTSIDE AR INTAIES. ELECTRICAL COORDINATION NOTES 1. WHERE ROCKED ON EQUIPMENT SOEEDEEES, THE EQUIPMENT COMES COMPLETE FROM 111E FACTORY WITH MOTOR CONTROLS AS REQUIRED. ELECTRICIAN SNAIL PROVIDE SERVICE AND A DISCONNECT PER COOS, AND 00 ALL POWER WING, INCLUDING CONNECTING TO EQUPPMENT. 2. WHERE NDNCATED ON EQUIPMENT SC THE EQUIPMENT REQUIRES HELD INSTATED MOTOR STARTERS. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL MOTOR STARTERS (OR CONTACTORS WHERE INDICATED), PR0V10E SERVICE AND DISCONNECT PER CODE, AND DO ALL POWER WANG, INCLUDING CONNECTING TO EQUIPMENT HOLDING COIL CIRCUIT SHALL BE POWERED BY ELECTRICAL CONTRACTOR (120 VOLT /1 PH. UNLESS INDICATED OTHERWISE). ALL STARTERS SHALL BE PROVIDED WITH 11-0-A SWITCH. 3. 2 - 120V CONTROL CIRCUITS PER FLOOR ARE REQUIRED. EC. SHALL PROVIDE SERVICE AND A DISCONIECT PER CODE, AND DO ALL POWER WRING. INCLUDING CONNECTING TO CONTROLS CONTRACTOR PROVIDED TRANSFORMERS AND EQUIPMENT. • SEISMIC RESTRAINING NOTES 1. ANY BASE - MOUNTED /SPRING- MOUNTED EQUIPMENT SHALL HAVE TOTALLY INCLOSED, SEISMIC RATED SPRINGS (MASON MODEL. SSLFH OR EQUAL), OR OPEN SPRINGS PLUS SEISMIC 'SNUBBERS' (MASON MODEL Z -1225 OR EQUAL). 2. ALL SPRING MOUNTED, SUSPENDED EQUIPMENT SHALL HAVE SEISMIC CABLES LiNSTAIlED N AMMON TO EQUIPMENT HANGERS. CABLES SHALL BE INSTALLED DIAGONALLY UP AND AWAY FROM EQUIPMENT COWERS AND BE ATTACHED TO 111E STRUCTURE ABOVE CABLES SHALL BE LEFT PARTIALLY SLACK. SiZE AND INSTALL CABLES PER STIACNA SEISMIC RESTRAINT MANUAL 3. ANY EQUIPMENT MOUNTED RIGIDLY TO TIE B1EDNG STRUCTURE SHALL NOT REQUIRE ADDITIONAL SERSIRIC RESTRAINT. 4. RESTRAIN ALL RECTANGULAR DUCTS 6 SQ. FT. OF AREA AND LARGER AND AIL ROUND DUCTS 28' N DIAIEiER AND URGER. RESTRAINTS SHALL OCCUR 30 FEET O.C. MAXIMUM AND SHALL BE NSTA LED AT EVERY DUCT TURN AND AT THE END OF THE DUCT RUN. SEE MD INSTALL RESTRAINTS PER SMACNA SEISMIC RESTRAINT MALARIAL 5. ALL CEILING MOUNTED DIFFUSERS SHALL HAVE WIRES (16 GA.) ATTACHED TO TIE ABOVE FLOOR SLAB OR STRUCTURE. SAFETY WIRES SHALL BE LEFT PARTIALLY SLACK ALTERNATE MEiHOD SHALL BE TO ATTACH DIFFUSERS TO T-BAR GRID W11H SCREWS, RIVETS, OR CEILING CUPS FOR TERIA A S VEIGHING LESS THAN 20 POUNDS. SHEET METAL NOTES 1. DUCT SIZES INDICATED ON RAG ME NET NSOE DIMENSIONS A CALL -OUT SUCH AS 12° X 1r/SL MEANS A 14' X 14' SHEET METAL DUCT WITH V SOURDLRER. CMG A PET INSIDE OWDNSiON OF IT X 12'. 2. THROUGH PEW1RATION ND =BRANS PENETRATION FIRE STOP AS REQUIRED N THE WC SILL BE PROVIDED AND INSTALLED BY TIE MECHANICAL CONTRACTOR FRE STOP SYS1E M SHAM BE 3M BRAD FIRE BNRRER CP 25INTT CNJUING OR APPROVED EQUIVALENT. NOTE PER UBC 714 EXCEP'11OIt FiRE MD COMBINATION FIRE AND SMOKE DAMPERS SHALL. BE MSTNIED N ACCORDANCE NTH TIER USiNGS. MANUFACTURER NSTALIATION INSTRUCTIONS DO NOT REQUIRE FIRE STOP BETWEEN SLEEVE NO ASSEMBLY PENETRATED 3. DUCTWORK( STALL BE CONSTRUCTED TO DYENSIONS IOCAiTD ON PLN . TIE TOLERANCE OF THESE CRUSTING SHALL BE AS SPECIFIED N HOLIDAY -PMKS, MC. SHOP STAMP/IDS MANUAL LENGTHS, AND CRT CAL Damson BETMEEN DUCTWORK Pa) OTHER DURDING/SYS1EM BOUTS NE INDICATED MALE A LOCATION OR EMENSION SCALED FROM TIE .CRATING UML NOT BE ADEQUATE. THE TOLERANCE OF CRITIC&. DIMENSIONS, F NOT MATED. SHALL WALT TO THAT OF 111E INSTNING MEcHNIC'S MEASURING OEMCES. SCALED LOCATIONS OR DIMINSING ARE NOT SUBJECT TO TOLEWWCE GIDELUI+ES. 4. THESE PLAINS HAVE BEEN COORONAtED VRH 111E AIRDIiECTUtM, STTUCTURAI,, SPRINGER AND ELECTRICAL CRAMS. NW CHANGES N DRS LAY -OUT MUST BE REVIEWED BY HOLIDAY -PAIR ENGINEERING l PAR` LENT. 1 1 T rzi XXXX 12x12 .3 HR 3 IR VERTICAL FRE DAMPER (3 HOUR) N AIRSTREAU RUSK IN 1100EL 0(823 STYLE A VERTICAL FiRE DAMPER (3 HOUR) N AIRSTREAM RUST IN MOOEL 01823 STYLE A l 1 / 8x24� 1=11111111■111111+ HVAC LEGEND DUCT ENDER POSITIVE PRESSURE DUCT ENDER NEGATIVE PRESSURE TURING VANES ELEVATION FROM F.F.L. 1N �TI AND C DI�lCT� EXTEND EQUIPMENT IDENTIFICATION THERMOSTAT SENSOR S.S.G. SiDEWALL SUPPLY GRILLE DOUBLE DEFLECTION, HORIZONTAL FRONT BLADES TITUS MODEL 272RL - KRUEGER MODE. 88011 S.R.G. SiDEWALL RETURN GRUE FIXED 35 DEGREE DEFLECTION BLADES, WITHOUT OBD TITUS MODEL 350111. - KRUEGER MODEL 580H SUPPLY AIR ARROW RETURN AIR ARROW SPEED SWITCH: FURNISHED BY HOLIDAY - PARKS, INSTALLED BY ELECTR CONTR. FLEXIBLE CONNECTION DUCT HEATER MANUAL VOLUME DAMPER MOTORiZED DAMPER BACK DRAFT DAMPER SMOKE DETECTOR VERTICAL FIRE DAMPER (1% HOUR) IN AIRSTREAM RAISON MODEL 0182 STYLE A HORIZONTAL FIRE DAMPER (1Y2 HOUR) N AIRSTREAM RUUSKN MODEL DIB2 STYLE A BACK DRAFT DAMPER RUST IN MODEL BD2/A1, LOCAL VELOCITY < 1500 FPM BACK DRAFT DAMPER RUSKII MODEL. BD2/A2, LOCAL VELOCITY < 2500 FPM BACK DRAFT DAMPER RUSKIN MODEL 806, LOCAL VELOCITY < 3500 FPM SMOKE DAMPER HORIZONTAL VERTICAL COM8INAiiON SMOKE AND FIRE DAMPER VERTICAL COMBINATION SMOKE NO FRE DAMPER SPIN-I1 THE -OFF & VOLUME DAMPER INDICATES 14' x 14' o.0. SIfEBMETAL WI1HH 1' SOUNDLNER (11.1.0) 12° x 12' NET ID. INDICATES UNWED 1 r x 12' S.M. DUCT INDICATES 1r x it I.D. DUCTBOARD INDICATES UNWED 1r x 12' S.Y. DUCT WH INSULATED TRAP RUSE OR DROP N DIRECTION OF FLOW FLEXIBLE DUCT MATES FIAT OVAL DUCT SPIN -1111 THE -OFF & W UiE DAMPER w1H HRIGO ROOM FBERQ.ASS DUCT IMAM DIRECTION THROUGH O WRONG O TIE GONE • o: GRILLES, REGISTERS, DIFFUSERS LEGEND S.S.G. S.R.G. SiDEWALL SUPPLY GRILLE DOUBLE DEFLECTION. HORIZONTAL FRONT BLADES TITUS MODEL 272RL - KRUEGER MODEL 88011 SIDEWALL RETURN GRILLE FIXED 35 DEGREE DEFLECTION BLADES, ITHOUT OBD TITUS MODEL 35081- KRUEGER MODEL 58011 AFF AP DOD BHP BU CONK. DMPR. O. EA EAT EC. ELEV. ESP Fa FlA FIR. DR. FOB FOT FUT GC ABOVE FINISHED FLOOR ACCESS PANEL BACK DRAFT DAMPER BRAKE HORSE POWER BOTTOM OF UHT CONNECT/CONFECTION DAMPER DOWN DRAIN EACH ENTERIC AR TEMP ELECTRICAL CONTRACTOR ELEVATION EXTERNAL STATIC PRESSURE FiRE DAMPER FINISHED FLOOR LEVEL FULL LOAD AMPS FLOOR DRAIN FLAT ON BOTTOM FLAT ON TOP FUTURE GENERAL CONTRACTOR HVAC ABBREVIATIONS HIP HORSE POWER D INSTIL IAT MCA N/A NC tic NO NOM. NTS OA OD PRIM PSI RA SA SM SP TYP VD W/ INSIDE DIMENSION/OUWETER INSULATION LEAVING AR TEMP MNWIII CIRCUIT RAPACITY NOT APPLICABLE NORMALLY CLOSED NOT N CONTRACT NORMALLY OPEN NOMRUL NOT TO SCALE OUTSIDE AR OUTSIDE DIIENSION PRIMARY POUNDS PER SQUARE NCH RISE RETURN AIR SUPPLY AIR SHEET METAL STATIC PRESSURE TYPICAL VOLUME DAMPER WITH LEGAL DESCRIPTION 13 Rfl RURBAN ADD TO SEATTLE POR OF SE y4 OF SW y4 OF SEC 23 -23-04 - BEG SW COR OF SE Y4 TH N 89 -40-24 W 65.40 FT THH N 00 -19-36 E 40 FT TO TPOB T11 CONIC N 00 -19-36 E 110 FT 111 N 89 -40-24 W 151.60 FT TN S 00 -19-36 W 110 FT 111 S 89-40-24 E 151.60 FT TO TPOB 1: 3: 4: 5: COMIC CAPACITY N MOH AT 80 4b/67 orb, BY F. ds OUTDOORS HEATING CAPACITY AT 20' F. OUTDOORS ACCESSOIES INCLUDE: LOW AIUENT KIT POWER WIRING MD DISCONNECT PROVIDED AND INSTALLED BY EC. T -STAT SHAT BE PROVIDED AND NSTALED BY CONTROLS CONTRACTOR (M.0 ) • SCOPE OF WORK 1. INSTAL (1) NEW 3 TON WALL MOUNTED SELF - CONTAINED HEAT PUMP. 2, INSTALL STAND -ALONE THERMOSTAT AS SHOWN. 3. INSTALL TWO (2) WAIL SLEEVES, ONE (1) SUPPLY GRAIL AND ONE (1) RETURN GRILLE AS SHOWN. 4. START, TEST & ADJUST SYSTEM. SEQUENCE OF OPERATION HEAT PIMP TO OPERATE BASED ON STAND -ALONE THERMOSTAT. ALL OTHER EXISTING EQUIPMENT PER BUILDING STANDARD. CRAWS I DATES MEP ORNfIC Pernik No 04/0 Pb n review approval Is subject to laps and A*+Drael cT coestn.tion documents does not aullrorto the violation c: aooepxed code or ordnance. Receipt No dunes shag be made to the scope c: v. - cr:c without prior approval ci T c:csvlli Building D :n. NOTE: RE c(s ree a new pan submittal end n y include additional pan review tees. 21-3 PENDING CRY APPROVAL Oty of Tukwila BUILDING DIVISION Ex is D MAY 26 2007 APPROVED FOR CONSTRUCTION • l C REVIEWED E FOR 1 i- ,Er1 1 nno ^ / nu � c ,^ n Nov 2 i 2 06 1 ►Ly: f7 Ci ' Of Tukwila BUILDING DMSON SEPARATE PERMIT REQUIRED FOR El Methanol VElectrIcal Ofpsnbkig QS nom City of Tukwila BUILDING DIVISION RECEYEti mop Tvievni a 1401 $ 7 PERMITCENTER CO 0 W 9 U) 0 z z W hiC It ti it e$ Nisi „b K$ MC A • C 2 I C Co C 00 O MO elide Os saw M001 m � Fg .4 co co < e rr, it t. LA 0 U 0 D PI cn • 4eI. 4rf io4e e��1doR 11/15/06 e • I, • • 3 m: 8 1 141 ;I 1 It 1 • FIRST FLOOR HVAC PLAN SOUTHCENTER GARAGE B 633 SOUTHCENTER MALL TUKWILA, WA 98188 mei • .,. i op soot.: 1/16" * 1 —V .n9In..rd: drown: GR 1 : t 3 (I' t 1: . original � 74 numbers current 48 �74ym�R . C"' JI � v 0 0 • .) 4,7 n om v n rn 4p HOLADAYPARKS, INC. 4100 S. 134th Alan. Settlio. WA 98168 P.O. float 6!208 (206) 248 -1700 STATE CONTRACTORS' UCENSE NUMBER: HOIADP1379NO m m a cr