HomeMy WebLinkAboutPermit M06-273 - WESTFIELD SOUTHCENTER MALL - PARKING GARAGE BWESTFIELD PARKING
GARAGE "B"
633 SOUTHCENTER MALL
EXPIRED 5 -26 -07
M06 -273
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.cttukwila.wa.us
2623049023
633 SOUTRCENTER MALL TUKW
WESTFIELD PARKING GARAGE B
633 SOUTHCENTER MALL , TUXWILA WA
Owner:
Name: WESTFIELD CORPORATION LLC
Address: 11601 WILSHIRE BL , LOS ANGELES CA
Contact Person:
Name: PEGGY PEEL
Address: 4600 S 134 PL , SEATTLE WA
Contractor:
Name: HOLADAY PARKS, INC.
Address: PO BOX 69208 , SEATTLE, WA
Contractor License No: HOLADPI379NO
DESCRIPTION OF WORK:
INSTALL (1) HEAT PUMP
Value of Mechanical: $4,430.00
Type of Fire Protection:
Furnace: <100K BTU
> 100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat/Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
MECHANICAL PERMIT
0
0
0
0
0
1
0
0
0
0
0
0
0
0
EQUIPMENT TYPE AND QUANTITY
Fees Collected:
* *continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 206 248 -8747
Phone: 206 248 -9700
Expiration Date: 09/03/2007
Steven M. Mullet, Mayor
Steve Lancaster, Director
M06 -273
11/27 /2006
05/26/2007
International Mechanical Code Edition: 2003
Boiler Compressor:
0-3 HP /100,000 BTU 0
3 HP /500,000 BTU 0
16-30 HP /1,000,000 BTU 0
30 HP /1,750,000 BTU 0
80 +HP /1,780,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 1
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment
$211.95
dot: IMC -10/06 M06 -273 Printed: 11 -27 -2006
Permit Center Authorized Signature.
I hereby certify that I have read an
governing this work will be compli
The grantin
constructio
Signature:
Print Name:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: httn: / /www.ci.tukwila.wa.us
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Number: M06 -273
Issue Date: 11/27/2006
Permit Expires On: 05/26/2007
Date:
permit and know the same to be true and correct. All provisions of law and ordinances
r specified herein or not.
permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
pert c: of wor am authorized to sign and obtain this mechanical permit.
Date: I I — 1 - 15 -( c= ,
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -10/06 M06 -273 Printed: 11 -27 -2006
Parcel No.: 2623049023
Address:
Suite No:
Tenant:
� b
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
633 SOUTECENTER MALL TURW
WESTFIELD PARRING GARAGE B
1: ** *BUILDING DEPARTMENT CONDN7ONS * **
PERMIT CONDITIONS
* *continued on next page **
Permit Number:
Status:
Applied Date:
Issue Date:
M06 -273
ISSUED
11/17 /2006
11/27/2006
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
8: Manufacturers installation instructions shall be available on the job site at the time of inspection.
6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
7: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department
of Labor and Industries (206/248 - 6630).
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: Cond -10/06 M06 -273 Printed: 11 -27 -2006
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction •- t •erforman e of work.
Signature:
doe: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.cttukwila.wa.us
Print Name: 1A-44i C C_ - T `�
Date: I 7-6
M06-273 Printed: 11 -27 -2006
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://Www.ci.tukwila.wa.us
CONTACT PERSON
Name: 24 79 y Pee / Day Telephone:
Mailing Address: 40 O S. f 3 !
Sea-al P
r1t City
E -Mail Address: pony p PJ rl o fa day pa r K' . 0 . D m Fax Number:
>Vo TA IC S,
Contact Person: Toy Peel
E -Mail Address: Pi ( to(adayparkS.CO
Contractor Registration Number: AcA 11 PT 3 i9/143
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Q:UpplicmionsWorms- AppItcelions On Line\3-200(- Permit Applic,tioadoc
Revised: 4 -2006
bit
Building Permit No.
Mechanical Permit No. mg Q
Plumbing/Gas Permit No.
Public Works Permit No.
Project No. Fb&-e'
(For office use only) - -
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted hrough the mail or by fax.
* *Please Pent**
SITE LOCATION
n . r,� King Co Assessor's Tax No.: 3 snf 7 00 - 0 2 4' 7
Site Address: 4 33 go ttitke P�t'P r /Ha I I Suite Number: Floor:
Tenant Name: So ukkco K t♦ r ur w e KRh9 N e w Tena nt: ,;,
Car Yes ❑.,No
Property Owners Name: b)e c t v Id Car arat l p,«
Mailing Address: 460 0 S . / A 4 It Pi
c7PA ttit
City
COAL 9 &Ha
State Zip
-RO/p -44/9-2747
(A IA- 9g /€09'
State
Zip
.a 6 -a18 -8
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) )
Company Name: n
Mailing Address 4'400 S. /3 41 pi cSpa'ttl'e I 444-- 2C /62
City
Day Telephone: -- ( 0 1 19- g 717
Fax Number: „? O 6 • 71� -� 70
Expiration Date:
State Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
State
Zip
Page! of 6
1
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace<100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace> I00K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /I,750,000 BTU
Appliance Vent
Hood and Duct
Water Heater
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig/Cooling
System
Incinerator - Domestic
Emergency
Generator
Air Handling Unit
<10,000 CFM
Incinerator - Comm/Ind
Other Mechanical
Equipment
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information): -P t_ C / \ )
MECHANICAL PERMIT INFORMATION — 206 -431 -3670
MECHANICAL CONTRACTOR INFORMATION
Company Name /70L // At D AY T T �/stirs _rive .
Mailing Address:
City State Zip
Contact Person: C91Q_M-7 1 -Q- Day Telephone: id (., -� ` Q 71
E -Mail Address: DC a C ol[t a y pet rAt s Co m Fax Number: .7 o !e - „tie Q 70 o
Contractor Registration Number: t`/OL A DPI' 3 7'7 A/O Expiration Date: 9/O 3/0 7
Use: Residential: New .... ❑ Replacement....❑
Commercial: New ....Lir Replacement .... ❑
Fuel Type: Electric aj / Gas....❑ Other:
)� -a.& 1Ju rttr
Indicate type of mechanical work being installed and the quantity below:
Q:Upplications\Fonns- Applications On Is :3- - Permit Application.dec
Revised: 4-2006
bh
Wio.
Page 4 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: TH `7ve�. Date: J// / 4 c
Print Name: 7 e t/ Pee) q q e Arta. Day .' Telephone: e 6 / aT 2 • g 7 1
Mailing Address: 44,470 S S. /34S A , (t) A- 4 ,4149
/// City State Zip
I Date Application Accepted:
t MIA?
Q: Applicatiom6mma- Applications On Line08006 Permit Application.doc
Revised: 4-2006
bh
Date Application Expires: _ y j 11 4
Staff Initials: / I
Page 6 of 6
Doc: RECSETS -OB
RECEIPT NO: R06 -01881
Initials: JEM Payment Date: 11/27/2006
UseIID: 1165
Payee: HOLADAY - PARRS, INC.
SET ID: 1127 SET NAME: HOLADAY -PARKS
SET TRANSACTIONS:
Set Member Amount
M06 -272 175.56
178.34
TOTAL: 175.56
TRANSACTION LIST:
Type Method Description Amount
Payment Check 157200 353.90
TOTAL: 353.90
ACCOUNT ITEM LIST:
Description
MECHANICAL - NONRES
PLAN CHECK - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206-431 -3665
Web site. http: //www.ci.tukwila.wa.us
SET RECEIPT
Total Payment: 353.90
Account Code Current Pmts
000/322.100 351.12
000/345.830 2.78
TOTAL: 353.90
2099 11/27 9716 TOTAL 353.90
Doc: RECSEIS -06
RECEIPT NO: R06-01853
Initials: JEM
User ID: 1165
Payee: HOLIDAY PARKS, INC.
SET ID: S000000625 SET NAME: limp set/Initialized Activities
SET TRANSACTIONS:
Set Member Amount
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: /Amvw.ci.tukwila.wa.us
M06 -272 36.39
M06 -273 33.61
TOTAL: 36.39
ACCOUNT ITEM LIST:
Description
TRANSACTION LIST:
Type Method Description Amount
Payment Cash 70.00
TOTAL: 70.00
PLAN CHECK - NONRES
SET RECEIPT
Account Code Current Pmts
000/345.830
TOTAL:
Payment Date: 11/17/2006
Total Payment: 70.00
70.00
70.00
n ,
_. .._ iu ij)friL.
04 -05 -2007
PEGGY PEEL
4600 S 134 PL
SEATTLE WA 98168
RE: Permit No. M06 -273
633 SOUTHCENTER MALL TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206. 431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for
additional periods not exceeding 90 days each. Extension requests must be In writing and provide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 05/26/2007 , your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
fer Marshall,
Permit Technician
xc: Permit File No. M06 -273
City of Tukwila Steven M Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 - 3670 • Fax: 206 - 431 - 3665
ACTIVITY NUMBER: M06 -273 DATE: 11 -17 -06
PROJECT NAME: WESTFIELD PARKING GARAGE B
SITE ADDRESS: 633 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
0 M1190
Bui i Division
Public Works
Complete
Comments:
REVIEWER'S INITIALS:
Approved ❑
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.doc
2 -28 -02
PERMIT COORD COPY rnPY
PLAN REVIEW /ROUTING SLIP
APPROVALS OR CORRECTIONS:
Approved with Conditions
Q( I/ -2f
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete ❑
❑ Permit Coordinator ❑
Planning Division
DUE DATE: 11-21 -06
Not Applicable I 1
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route E Structural Review Required ❑ No further Review Required
DATE:
DUE DATE: 12-19-06
Not Approved (attach comments) ❑
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
HOLADPI379NO
Licensee Name
HOLADAY PARKS INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
578004089
Ind. Ins. Account Id
Business Type
CORPORATION
Address 1
PO BOX 69208
Address 2
City
SEATTLE
County
KING
State
WA
Zip
98188
Phone
2062489700
Status
ACTIVE
Specialty I
GENERAL
Specialty 2
UNUSED
Effective Date
1/21/1983
Expiration Date
9/3/2007
Suspend Date
Separation Date
Parent Company
Previous License
HOLADPF376NO
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
PARKS, GERALD T JR
01/01/1980
PARKS, DAVID L
01/01/1980
TALBOT, PAUL
01/01/1980
NELSON, MICHAEL
01/01/1980
BECK, DAVE
01/01/1980
OCONNOR, BONNY K
01/01/1980
NAILON, JUNE A
01/01/1980
Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L&I to perfonn
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Bond Information
https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= HOLADPI379NO 11/27/2006
HEAT PUMP SCHEDULE
HP I
AREA SERVED
YAKS
`
YOWL
COOING OWN}
11TG. CAP
MBH
FAN PERFORMANCE DATA
1
ESA.
MR
KW
r EEEC1TICAL
MGT.
ER.
COP
FLIERS
REIMS
TOTAL
SENNS.
CFR
ESP.
RPM
RIP
V/PH
MCA
QTY SIZE
T, 1
B EV MACHINE RM
BARD
VM361
37.96
27.58
20.9
1100
0.3
NA
-
0
5
230/1
53
380
9
2.9
1
16' X 30'
1, 2, 3, 4, 5
BASIS OF DESIGN
DESIGN CRITERIA CRITERIA SOURCE
1 2003 INTERNAL ORN. BUILDING CODE
EFFECTIVE AUGUST 15, 2004
2 2003 N1EIOMUONN. TECHAI:AL CODE
EFFECTIVE AUGUST 15, 2004
3 2003 WSEC (CHAPTER 51 -11 WAC)
EFFECTIVE AUGUST 15. 2004
r
5 OSA DESIGN TEMP = 83'F DB, 67T WS
6 ISA 0E5k8N TEIP = 50'F HEATING, 80T COOLING
7 EQUIPMENT LOAD = 36 TE I
PER PROPOSN.
• • •
GENERAL NOTES
1. AU. TRADES TO LEAVE W CLEARANCE N FRONT OF MECHANICAL EQUIPMENT
ACCESS PANELS FOR SERVICING.
2. CUTTING, FRAMING, PATCHING AND PANTING OF WALL. CEUNG AND FLOOR
OPENINGS SHALL BE BY GENERAL CONTRACTOR.
3. FINAL PNNiNG OF GRILLES, REGISTERS„ AND DIFFUSERS. AS MAY BE REQUIRED BY
ARCHITECT. SHALL BE DONE BY GENERAL CONTRACTOR.
4. GENERAL CONTRACTOR IS RESPONSIBLE FOR TEMPORARY HEAT DURING
CONSTRUCTION.
5. UNIT WEIGHTS AND LOCATIONS HAVE BEEN COOROINATED WI1H ARCHITECT AND
STRUCTURAL ENGINEER TO DETERMINE BUILDING STRUCTURAL ADEQUACY. F IT IS
NECESSARY TO RELOCATE AUNT. NOTIFY HOLIDAY- PARKS' ENGII€EHING
DEPARTMENT FOR RE-COORDINATION.
6. IN NO INSTANCE SHAD. OTHER TRADES HANG OR SUPPORT EQUIPMENT. CEUNG
WIRES, UGHT FIXTURE HANGERS, ETC., FROM HVAC EQUIPMENT OR DUCTWORK
7. PLUMBER SHALL ROUTE PLUMBING VENTS SO AS TO MAINTAIN MNMUR 15 FEET OF
CLEARANCE FROM OUTSIDE AR INTAIES.
ELECTRICAL COORDINATION NOTES
1. WHERE ROCKED ON EQUIPMENT SOEEDEEES, THE EQUIPMENT COMES COMPLETE
FROM 111E FACTORY WITH MOTOR CONTROLS AS REQUIRED. ELECTRICIAN SNAIL
PROVIDE SERVICE AND A DISCONNECT PER COOS, AND 00 ALL POWER WING,
INCLUDING CONNECTING TO EQUPPMENT.
2. WHERE NDNCATED ON EQUIPMENT SC THE EQUIPMENT REQUIRES HELD
INSTATED MOTOR STARTERS. ELECTRICAL CONTRACTOR SHALL FURNISH AND
INSTALL MOTOR STARTERS (OR CONTACTORS WHERE INDICATED), PR0V10E SERVICE
AND DISCONNECT PER CODE, AND DO ALL POWER WANG, INCLUDING CONNECTING
TO EQUIPMENT HOLDING COIL CIRCUIT SHALL BE POWERED BY ELECTRICAL
CONTRACTOR (120 VOLT /1 PH. UNLESS INDICATED OTHERWISE). ALL STARTERS SHALL
BE PROVIDED WITH 11-0-A SWITCH.
3. 2 - 120V CONTROL CIRCUITS PER FLOOR ARE REQUIRED. EC. SHALL PROVIDE SERVICE
AND A DISCONIECT PER CODE, AND DO ALL POWER WRING. INCLUDING CONNECTING
TO CONTROLS CONTRACTOR PROVIDED TRANSFORMERS AND EQUIPMENT.
•
SEISMIC RESTRAINING NOTES
1. ANY BASE - MOUNTED /SPRING- MOUNTED EQUIPMENT SHALL HAVE TOTALLY
INCLOSED, SEISMIC RATED SPRINGS (MASON MODEL. SSLFH OR EQUAL), OR OPEN
SPRINGS PLUS SEISMIC 'SNUBBERS' (MASON MODEL Z -1225 OR EQUAL).
2. ALL SPRING MOUNTED, SUSPENDED EQUIPMENT SHALL HAVE SEISMIC CABLES
LiNSTAIlED N AMMON TO EQUIPMENT HANGERS. CABLES SHALL BE INSTALLED
DIAGONALLY UP AND AWAY FROM EQUIPMENT COWERS AND BE ATTACHED TO 111E
STRUCTURE ABOVE CABLES SHALL BE LEFT PARTIALLY SLACK. SiZE AND INSTALL
CABLES PER STIACNA SEISMIC RESTRAINT MANUAL
3. ANY EQUIPMENT MOUNTED RIGIDLY TO TIE B1EDNG STRUCTURE SHALL NOT
REQUIRE ADDITIONAL SERSIRIC RESTRAINT.
4. RESTRAIN ALL RECTANGULAR DUCTS 6 SQ. FT. OF AREA AND LARGER AND AIL
ROUND DUCTS 28' N DIAIEiER AND URGER. RESTRAINTS SHALL OCCUR 30 FEET
O.C. MAXIMUM AND SHALL BE NSTA LED AT EVERY DUCT TURN AND AT THE END OF
THE DUCT RUN. SEE MD INSTALL RESTRAINTS PER SMACNA SEISMIC RESTRAINT
MALARIAL
5. ALL CEILING MOUNTED DIFFUSERS SHALL HAVE WIRES (16 GA.) ATTACHED TO TIE
ABOVE FLOOR SLAB OR STRUCTURE. SAFETY WIRES SHALL BE LEFT PARTIALLY
SLACK ALTERNATE MEiHOD SHALL BE TO ATTACH DIFFUSERS TO T-BAR GRID W11H
SCREWS, RIVETS, OR CEILING CUPS FOR TERIA A S VEIGHING LESS THAN 20
POUNDS.
SHEET METAL NOTES
1. DUCT SIZES INDICATED ON RAG ME NET NSOE DIMENSIONS A CALL -OUT SUCH AS
12° X 1r/SL MEANS A 14' X 14' SHEET METAL DUCT WITH V
SOURDLRER. CMG A PET INSIDE OWDNSiON OF IT X 12'.
2. THROUGH PEW1RATION ND =BRANS PENETRATION FIRE STOP AS REQUIRED N
THE WC SILL BE PROVIDED AND INSTALLED BY TIE MECHANICAL CONTRACTOR
FRE STOP SYS1E M SHAM BE 3M BRAD FIRE BNRRER CP 25INTT CNJUING OR
APPROVED EQUIVALENT. NOTE PER UBC 714 EXCEP'11OIt FiRE MD COMBINATION
FIRE AND SMOKE DAMPERS SHALL. BE MSTNIED N ACCORDANCE NTH TIER
USiNGS. MANUFACTURER NSTALIATION INSTRUCTIONS DO NOT REQUIRE FIRE STOP
BETWEEN SLEEVE NO ASSEMBLY PENETRATED
3. DUCTWORK( STALL BE CONSTRUCTED TO DYENSIONS IOCAiTD ON PLN . TIE
TOLERANCE OF THESE CRUSTING SHALL BE AS SPECIFIED N HOLIDAY -PMKS, MC.
SHOP STAMP/IDS MANUAL LENGTHS, AND CRT CAL Damson BETMEEN
DUCTWORK Pa) OTHER DURDING/SYS1EM BOUTS NE INDICATED MALE A
LOCATION OR EMENSION SCALED FROM TIE .CRATING UML NOT BE ADEQUATE. THE
TOLERANCE OF CRITIC&. DIMENSIONS, F NOT MATED. SHALL WALT TO THAT
OF 111E INSTNING MEcHNIC'S MEASURING OEMCES. SCALED LOCATIONS OR
DIMINSING ARE NOT SUBJECT TO TOLEWWCE GIDELUI+ES.
4. THESE PLAINS HAVE BEEN COORONAtED VRH 111E AIRDIiECTUtM, STTUCTURAI,,
SPRINGER AND ELECTRICAL CRAMS. NW CHANGES N DRS LAY -OUT MUST BE
REVIEWED BY HOLIDAY -PAIR ENGINEERING l PAR` LENT.
1
1
T
rzi
XXXX
12x12
.3 HR
3 IR VERTICAL FRE DAMPER (3 HOUR) N AIRSTREAU
RUSK IN 1100EL 0(823 STYLE A
VERTICAL FiRE DAMPER (3 HOUR) N AIRSTREAM
RUST IN MOOEL 01823 STYLE A
l
1 /
8x24�
1=11111111■111111+
HVAC LEGEND
DUCT ENDER POSITIVE PRESSURE
DUCT ENDER NEGATIVE PRESSURE
TURING VANES
ELEVATION FROM F.F.L.
1N �TI AND C DI�lCT� EXTEND
EQUIPMENT IDENTIFICATION
THERMOSTAT
SENSOR
S.S.G. SiDEWALL SUPPLY GRILLE
DOUBLE DEFLECTION, HORIZONTAL FRONT BLADES
TITUS MODEL 272RL - KRUEGER MODE. 88011
S.R.G. SiDEWALL RETURN GRUE
FIXED 35 DEGREE DEFLECTION BLADES, WITHOUT OBD
TITUS MODEL 350111. - KRUEGER MODEL 580H
SUPPLY AIR ARROW
RETURN AIR ARROW
SPEED SWITCH: FURNISHED BY HOLIDAY - PARKS,
INSTALLED BY ELECTR CONTR.
FLEXIBLE CONNECTION
DUCT HEATER
MANUAL VOLUME DAMPER
MOTORiZED DAMPER
BACK DRAFT DAMPER
SMOKE DETECTOR
VERTICAL FIRE DAMPER (1% HOUR) IN AIRSTREAM
RAISON MODEL 0182 STYLE A
HORIZONTAL FIRE DAMPER (1Y2 HOUR) N AIRSTREAM
RUUSKN MODEL DIB2 STYLE A
BACK DRAFT DAMPER
RUST IN MODEL BD2/A1, LOCAL VELOCITY < 1500 FPM
BACK DRAFT DAMPER
RUSKII MODEL. BD2/A2, LOCAL VELOCITY < 2500 FPM
BACK DRAFT DAMPER
RUSKIN MODEL 806, LOCAL VELOCITY < 3500 FPM
SMOKE DAMPER
HORIZONTAL VERTICAL COM8INAiiON SMOKE AND FIRE
DAMPER
VERTICAL COMBINATION SMOKE NO FRE DAMPER
SPIN-I1 THE -OFF & VOLUME DAMPER
INDICATES 14' x 14' o.0. SIfEBMETAL WI1HH
1' SOUNDLNER (11.1.0) 12° x 12' NET ID.
INDICATES UNWED 1 r x 12' S.M. DUCT
INDICATES 1r x it I.D. DUCTBOARD
INDICATES UNWED 1r x 12' S.Y. DUCT
WH INSULATED TRAP
RUSE OR DROP N DIRECTION OF FLOW
FLEXIBLE DUCT
MATES FIAT OVAL DUCT
SPIN -1111 THE -OFF & W UiE DAMPER w1H
HRIGO ROOM FBERQ.ASS DUCT
IMAM DIRECTION THROUGH
O WRONG O TIE GONE
•
o:
GRILLES, REGISTERS, DIFFUSERS LEGEND
S.S.G.
S.R.G.
SiDEWALL SUPPLY GRILLE
DOUBLE DEFLECTION. HORIZONTAL FRONT BLADES
TITUS MODEL 272RL - KRUEGER MODEL 88011
SIDEWALL RETURN GRILLE
FIXED 35 DEGREE DEFLECTION BLADES, ITHOUT OBD
TITUS MODEL 35081- KRUEGER MODEL 58011
AFF
AP
DOD
BHP
BU
CONK.
DMPR.
O.
EA
EAT
EC.
ELEV.
ESP
Fa
FlA
FIR. DR.
FOB
FOT
FUT
GC
ABOVE FINISHED FLOOR
ACCESS PANEL
BACK DRAFT DAMPER
BRAKE HORSE POWER
BOTTOM OF UHT
CONNECT/CONFECTION
DAMPER
DOWN
DRAIN
EACH
ENTERIC AR TEMP
ELECTRICAL CONTRACTOR
ELEVATION
EXTERNAL STATIC PRESSURE
FiRE DAMPER
FINISHED FLOOR LEVEL
FULL LOAD AMPS
FLOOR DRAIN
FLAT ON BOTTOM
FLAT ON TOP
FUTURE
GENERAL CONTRACTOR
HVAC ABBREVIATIONS
HIP HORSE POWER
D
INSTIL
IAT
MCA
N/A
NC
tic
NO
NOM.
NTS
OA
OD
PRIM
PSI
RA
SA
SM
SP
TYP
VD
W/
INSIDE DIMENSION/OUWETER
INSULATION
LEAVING AR TEMP
MNWIII CIRCUIT RAPACITY
NOT APPLICABLE
NORMALLY CLOSED
NOT N CONTRACT
NORMALLY OPEN
NOMRUL
NOT TO SCALE
OUTSIDE AR
OUTSIDE DIIENSION
PRIMARY
POUNDS PER SQUARE NCH
RISE
RETURN AIR
SUPPLY AIR
SHEET METAL
STATIC PRESSURE
TYPICAL
VOLUME DAMPER
WITH
LEGAL DESCRIPTION
13 Rfl RURBAN ADD TO SEATTLE POR OF SE y4 OF SW y4 OF SEC 23 -23-04 - BEG SW COR OF
SE Y4 TH N 89 -40-24 W 65.40 FT THH N 00 -19-36 E 40 FT TO TPOB T11 CONIC N 00 -19-36
E 110 FT 111 N 89 -40-24 W 151.60 FT TN S 00 -19-36 W 110 FT 111 S 89-40-24 E 151.60 FT TO TPOB
1:
3:
4:
5:
COMIC CAPACITY N MOH AT 80 4b/67 orb, BY F. ds OUTDOORS
HEATING CAPACITY AT 20' F. OUTDOORS
ACCESSOIES INCLUDE: LOW AIUENT KIT
POWER WIRING MD DISCONNECT PROVIDED AND INSTALLED BY EC.
T -STAT SHAT BE PROVIDED AND NSTALED BY CONTROLS CONTRACTOR (M.0 )
•
SCOPE OF WORK
1. INSTAL (1) NEW 3 TON WALL MOUNTED SELF - CONTAINED HEAT PUMP.
2, INSTALL STAND -ALONE THERMOSTAT AS SHOWN.
3. INSTALL TWO (2) WAIL SLEEVES, ONE (1) SUPPLY GRAIL AND ONE (1) RETURN GRILLE AS SHOWN.
4. START, TEST & ADJUST SYSTEM.
SEQUENCE OF OPERATION
HEAT PIMP TO OPERATE BASED ON STAND -ALONE THERMOSTAT. ALL OTHER EXISTING EQUIPMENT PER
BUILDING STANDARD.
CRAWS I DATES
MEP
ORNfIC
Pernik No
04/0
Pb n review approval Is subject to laps and
A*+Drael cT coestn.tion documents does not aullrorto
the violation c: aooepxed code or ordnance. Receipt
No dunes shag be made to the scope
c: v. - cr:c without prior approval ci
T c:csvlli Building D :n.
NOTE: RE c(s ree a new pan submittal
end n y include additional pan review tees.
21-3
PENDING CRY APPROVAL
Oty of Tukwila
BUILDING DIVISION
Ex is D
MAY 26 2007
APPROVED
FOR CONSTRUCTION
•
l C REVIEWED E FOR
1 i-
,Er1 1 nno ^ / nu � c ,^ n
Nov 2 i 2 06
1
►Ly: f7
Ci ' Of Tukwila
BUILDING DMSON
SEPARATE PERMIT
REQUIRED FOR
El Methanol
VElectrIcal Ofpsnbkig
QS nom
City of Tukwila
BUILDING DIVISION
RECEYEti
mop Tvievni a
1401 $ 7
PERMITCENTER
CO
0
W
9
U)
0
z
z
W
hiC
It
ti it
e$
Nisi
„b
K$
MC A
•
C
2
I
C
Co
C
00 O
MO
elide Os saw
M001
m �
Fg
.4 co co
< e rr,
it
t. LA
0
U
0
D PI
cn
•
4eI. 4rf io4e e��1doR
11/15/06
e
•
I,
•
•
3
m:
8
1
141
;I 1
It
1 •
FIRST FLOOR HVAC PLAN
SOUTHCENTER GARAGE B
633 SOUTHCENTER MALL
TUKWILA, WA 98188
mei
•
.,.
i
op
soot.:
1/16" * 1 —V
.n9In..rd: drown:
GR
1 :
t 3
(I'
t 1:
.
original � 74 numbers current 48 �74ym�R
.
C"'
JI
� v 0 0
• .)
4,7 n om
v
n
rn
4p HOLADAYPARKS, INC.
4100 S. 134th Alan. Settlio. WA 98168
P.O. float 6!208 (206) 248 -1700
STATE CONTRACTORS'
UCENSE NUMBER: HOIADP1379NO
m
m
a
cr