Loading...
HomeMy WebLinkAboutPermit M06-277 - TAZELAAR RESIDENCETAZELAAR RESIDENCE 12624 34 AV S M06 -277 Parcel No.: 7340600621 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 12624 34 AV 5 TUKW TAZELAAR RESIDENCE 12624 34 AV S , TUKWILA WA TAZELAAL ANNEMARIELU PO BOX 68603 , SEATTLE WA MICHELLE FOX 9367 RAINIER AV S , SEATTLE WA Contractor: Name: ROSSOE ENERGY SYSTEMS INC Address: PO BOX 18259 , SEATTLE WA 98118 Contractor License No: ROSSOES101LL MECHANICAL PERMIT DESCRIPTION OF WORK: INSTALL OIL TO OIL FURNACE CHANGE OUT IN BASEMENT - 105,000 BTU. Value of Mechanical: Type of Fire Protection: $3,154.00 Furnace: <IOOK BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Conunercial/Industrial Fees Collected: $OUIPMENT TYPE AND OUANTITY 0 0 0 0 0 1 0 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Expiration Date: 05/25/2008 Steven M. Mullet, Mayor Steve Lancaster, Director Phone: Phone: 206- 725 -7555 Phone: 206 -725 -7555 MO6 -277 12/01/2006 05/30/2007 NONE International Mechanical Code Edition: 2003 Boiler Compressor: 0-3 HP /100,000 BTU 0 3-15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU 0 30-50 HP /1,750,000 BTU 0 00 +HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 $167.25 doe: IMC -10/06 M06 -277 Printed: 12 -01 -2006 Permit Center Authorized Signature: Signature: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: htto: / /www.ci.tukwila.wa.us fill '14 , ►II I Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: MO6 -277 Issue Date: 12/01/2006 Permit Expires On: 05/30/2007 Date:' 2 4/ 0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of 1 permit does not pr: 'ume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or performance of w • k. I am authorized to sign and obtain this mechanical permit. Date: Jz! I /fl Print Name: <erica ie'4G �C4,t t—tetp This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC-10 /06 MO6.277 Printed: 12 -01 -2006 Parcel No.: 7340600621 Address: Suite No: Tenant: 12624 34 AV S TUKW Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: httn: / /www.ci.tukwila.wa.us TAZELAAR RESIDENCE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M06 -277 ISSUED 12/01/2006 12/01/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 6: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 7: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 8: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4 inches shall be maintained above the controls with the strapping. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248 - 6630). 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. doc: Cond - 10/06 * *continued on next page** M06-277 Printed: 12 -01 -2006 Signature: Print Name: /Oka / /4 gGLLt� c4� 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Fax: 206431 -3665 Web site: httn: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: ( 2 4) /O e-, doc: Cond -10/06 M06 -277 Printed: 12 -01 -2006 *ma 1-111' ..I I r tit I UAWILA Community Development ?artment Public Works Department`" Permit Center RECEIVE 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Vomits phis \icc dungy \perms application (7-2004) P;97 1 3 211 COMMUNITY DEVELOPMENT Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** I King Co Assessor's Tax No.:7 M (DO 0 (.0 2.1 Site Address: 12- 102 `i 3 "\VZ �� i lA K W I I;l Suite Number: ' — Floor: New Tenant: ❑ .... Yes Tenant Name: Property Owners Name: Ql1n fY I rle.Xe. 'Ta aar Mailing Address: \2 -LD` ' - -P S TUKWt Name: Mailing Address: State City E -Mail Address: Fax Number: ENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page) Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance" ARCHITECy OF RECORD — All plans must be wet stamped by Architect of Record Companye: Mailing dress: Zip City Cont 34 Person: Day Telephone: E- ail Address: Fax Number: ENGINEEg OF RECORD All plans must be wet stamped by Engineer of Record J Company Name: Mailing Address: Zip City ontacy Person: Day Telephone: E -M *3l Address: Fax Number: it Page I Building Perm to. Mechanical Permit No Public`Wotks Permit No Project No City r ce use an W tale Day Telephone: State State �..No C ialt.0g Zip Zip Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<100K BTU - Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU °vmacc>10OK BTU rt � il) Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU ✓ oor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP/1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment MECHANICAL PERMIT INFO]ATION —206431-3670 MECHANICAL CONTRACTOR INFORMATION company Name: Z t -4 C. EN r 1\ Slyterrs % ailing Address: p CI 1 0-j 1 . 1\t r11 p Contact Person: 1 v t ViinQk2 E -Mail Address: Fax Number: Contractor Registration Number: <C Ue- 9c1.1a' k. ?- Expiration Date: I2- n-ot **An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance** Valuation of Project (contractor's bid price): S Scope of Work (please provide detailed information): f L.L Cam. Use: Residential: New ....0 Replacement t1. Commercial: New .... ❑ Replacement ❑ Fuel Type: Electric ❑ Gas ....0 Other: (— Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES - Applicable to a I permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: M \ C V14 \ P . M FAN/ Mailing Address:q ?,U l n %. int QK � S ` - 'K- tt t-e Date Application Accepted: Date Application Expires: its piu \icc chanaeatpennh application (7 -2004) Page 4 City Zip Day Telephone: 2.0b �7 Date: _N. Day Telephone:, 17S Wee S.% U City State Zap Staff Initials: Parcel No.: 7340600621 Address: 12624 34 AV S TUB:W Suite No: Applicant: TAZELAAR RESIDENCE Receipt No.: R06 -01896 Initials: BUJ User ID: ADMIN Payee: ROSSOE ACCOUNT ITEM LIST: Description MECHANICAL - RES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 72208 167.25 Account Code Current Pmts 000/322.100 167.25 Total: $167.25 Permit Number: M06 -277 Status: APPROVED Applied Date: 12/01/2006 Issue Date: Payment Amount: $167.25 Payment Date: 12/01/2006 03:20 PM Balance: $0.00 2331 12/05 9716 TOTAL 167.25 dot: Receiot -06 Printed: 12 -01 -2006 Pr �� L / L.GJfT r TYPe / - 7,44 1 // Address: /z� ga 1 /477/ S Date Called: Special Instructions: �y ( 1 /9 + / / / Date Wanted: /0 4 7 Requester one No: /: 24. / P c26 0 7- 5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 P79ti177 6, c .tc 06)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 9 v/I? tI�rh^r Inspect° : Dat {)0 REINSPECTJON FtE REQUI D. Prior o inspection. fee must be d at 6300 Southcenter Blvd.. Sui a 100. Call the schedule reinspection. Receipt No.; 'Date: 04 -05 -2007 MICHELLE FOX 9367 RAINIER AV S SEATTLE WA 98118 RE: Permit No. M06 -277 12624 34 AV S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 05/30/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 414-k Ter Marshall, Permit Technician xc: Permit File No. M06 -277 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206- 431 -3665 License Information License ROSSOESIOILL Licensee Name ROSSOE ENERGY SYSTEMS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600636219 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 18259 Address 2 City SEATTLE County KING State WA Zip 981180259 Phone 2067257555 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 6/13/1990 Expiration Date 5/25/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date OHIO CAS INS CO 3177900 05/09/2002 Until Cancelled 01/01/1980 512,000.00 05/14/2002 Business Owner Information Name Role Effective Date Expiration Date GLATZ, RONALD N 01/01/1980 WILLIAMS, ROBERT B 01/01/1980 WYMAN, DAVID C 01/01/1980 Look Up a Contractor, Electric ;nn or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= ROSSOES 101 LL 12/01/2006