Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M06-280 - SOLTERO RESIDENCE
SOLTERO RESIDENCE 4624 S 160 ST EXPIRED 06 -10 -07 M06 -280 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila.wa.us 2223049060 9624 S 160 ST TUKW DESCRIPTION OF WORK: REPLACE EXISTING GAS FURNACE City of Tukwila SOLTERO RESIDENCE 4624 S 160 ST , TUKWILA WA SOLTERO EXEQUIEL +KARLA M 4824 5 160TH ST , TUKWILA WA CHARLES DAY 28500 74 AV S , TUKWILA WA PERFORMANCE HEATING 7649 S 180 ST , KENT WA Contractor License No: PERFOHA180RT Value of Mechanical: $2,976.60 Type of Fire Protection: Furnace: <100KBTU 1 >100K BTU 0 Floor Furnace 0 Suspended/Wau/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Conunercial/Industrial 0 MECHANICAL PERMIT Fees Collected: VOUIPMENT TYPE AND OUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires Om Phone: Phone: 425251 -0356 Phone: 425 251 -0356 Expiration Date: 04/29/2007 Boiler Compressor: 0-3 HP /100,000 BTU 3 HP /500,000 BTU 18-30 HP /1,000,000 BTU 30-50 HP /1,750,000 BTU 80+ HP /1,750,000 BTU Fire Damper Diffuser Thermostat Wood/Gas Stove Water Heater Emergency Generator Other Mechanical Equipment Steven M. Mullet, Mayor Steve Lancaster, Director M06 -280 12/12/2006 06/10/2007 International Mechanical Code Edition: 2003 • • $158.94 • • doc: IMC - 10/06 M06 -280 Printed: 12 -12 -2006 Permit Center Authorized Signature I hereby certify that I have read an governing this work will be compile Signature: s City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Print Name: Ya\ \ 1 � tint. 'S • Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M06 -280 Issue Date: 12/12/2006 Permit Expires On: 06/10/2007 Date: 1 (24a, permit and know the same to be true and correct. All provisions of law and ordinances er specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constru ionertheperfc znanc +f work. I am authorized to sign and obtain this mechanical permit. Date: (2 1 Z/(-6 • This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC-10 /06 M06.280 Printed: 12 -12 -2006 Parcel No.: 2223049060 Address: Suite No: Tenant: 4624 3160 ST TUKW SOLTERO RESIDENCE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** arr City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. M06 -280 ISSUED 12/12/2006 12/12/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to • start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 8: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248 - 6630). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. • doc: Cond -10/06 M06 -280 Wilted: 12-12-2006 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us rnv • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Print Name: doc: Cond -10/06 Date: I2 (I ZI M06-280 Printed: 12 -12 -2006 Tenant Name: NIA Name: Charles Day CITY OF TUKWILA' Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Intp://www.cltulocila.wo us SITE LOCATION Site Address: 4624 S 160th St Mailing Address: 4624 S 160th St Mailing Address: 25500 74th Ave S E -Mail Address: Charleer4oerformanceheating.com Company Name: Performance Heating and Air Conditioning Mailing Address: 25500 74th Ave s Contact Person: Charles Day E -Mail Address Charles @PerformanceHeatinq.com Contractor Registration Number: PERFOHA15ORT Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Contact Person: E -Mail Address: Company Name: Mailing Address: Q: Wppliceamawoma- Applicotiom On LineU -2006- Permit Applise4w.doc Revised: 9-2006 M 21441-06 Contact Person: Day Telephone: E -Mail Address: Fax Number: Sow Building Permit No. Mechanical Permit No. Alt Ait Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: 2223049060 Suite Number: Floor: New Tenant: ❑ Yes ❑..No Property Owners Name: Ezuquiel Soltero Tukwila City Expiration Date: 4/28/n7 WA State Day Telephone: 425- 251 -0356 Kent WA City State Fax Number: 253 -867 -5775 Kent WA City State Day Telephone: 425 - 251 -0356 Fax Number: 253- 867 -5775 State 98188 Zip CONTACT PERSON — who do we contact when your permit is ready to be issued 98168 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) 98032 Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record City State Zip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU 1 Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator - 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator —Comm/Ind MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Performance Rear l nq & air conditioning Mailing Address: 25500 74th Ave 5 Kent WA City State Contact Person: Charles Day Day Telephone: 425- 251 -0356 E -Mail Address: charlesoperf ormanceheat inq.com Fax Number: 253- 867 -5775 Contractor Registration Number: PERFOHA150RT Expiration Date: 4/29/07 Valuation of Mechanical work (contractor's bid price): S 2976.60 Scope of Work (please provide detailed information): Replace existing gas tumace Use: Residential: New .... Replacement.... 13 Commercial: New .... ❑ Replacement .... ❑ 98032 Zip Fuel Type: Electric ❑ Gas.... © Other: Indicate type of mechanical work being installed and the quantity below: Q:Upylirsiin omut-Meniratiau On unet3-x006 -Remit MNiaioad« Revised: 9-2006 bh Page 4 of 6 BUILDING 7R R OR AUTH GENT: Signature: / Print Name: Charles Dav Mailing Address: 25500 74th Ave S Q:UppacLionskro nu- ApWiwiuu On rine3-29 6- Petnit Applicalondec Revisal: 9-2006 M Kent City PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiation of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Buildaw and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Pemtit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date; (2 Z_ t el C- Day Telephone: 425- 251 -0356 WA Stele 98032 Zip l Date Application Accepted: Date Application Expires: 4 � Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 2223049060 Permit Number: M06 -280 Address: 4624 3 160 3T TUKW Status: PENDING . Suite No: Applied Date: 12/12/2006 Applicant: SOLTERO RESIDENCE Issue Date: Receipt No.: R06 -01948 Initials: JEM Payment Date: 12/12/2006 02:54 PM User ID: 1165 Balance: 30.00 Payee: PERFORMANCE HEATING & AIR CONDITIONING, INC. TRANSACTION LIST: Type Method Description Amount Payment Check 50218 158.94 ACCOUNT ITEM LIST: De script ion MECHANICAL - RES Account Code Current Pmts 000/322.100 158.94 Total: $158.94 Payment Amount: $ 158.89 2641 12/12 9716 TOTAL 158.94 • • doe: Receiot -06 Printed: 12 -12 -2006 FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.) MODEL SPEED TAP 0.10 1. 0.20 0.30 040 0.50 0.60 0.70 0.80 0.90 TU0080R936K 4 - HIGH - Black 1392 1364 1335 1296 1247 1189 PUR 1042 3 - MED.- 4IGH - Blue 1210 1198 1177 1147 1107 1058 930 2 - MEa-LAW - Yellow 1046 1 T 1047 1033 1008 973 928 608 - LOW - Red 900 895 888 869 842 808 717 CFM VS. TEMPERATURE RISE MODEL CRA (CUBIC FEET PER MINUTE) 1000 1100 1200 1300 1400 7UD080R9361( 59 54 49 46 42 TAG: 1 7M DIA. NCI.ES ELECTRICAL CONNECTOR Ste .I' "O 0 2004 American Standard Inc ciJob l0llb 3. 13/16" 58(16 1 -Vt 044. NOLE 34r OASCONNECRON 2.1/8' PERFORMANCE NEAIINE 4' DIAMETER RUE CONNECT 40 Upflow / Horizontal Gas Furnace - Induced Draft - 2 Stage Heat TUD080R936K 7 E LE C CT TRI CO ,AL CONNECiWN (ALTERNATE) 1A? DM. KO. GAS (A CAS rHUC 03 MINED CRY OFTUKWLA DEC 1 2 2006 12/12/2006 15:57 TYPE Upton /Horizontal RATINGS 2 1st Stage Input BTUH 52000 1st stage Capacity BTUII (ICS) 3 41€73 2nd Sage Input STUN 80.000 2nd Stage Capacity BTUH OCS) 3 G1000 Temp. rise Min -Mai) "F 30- 60 BLOWER DRIVE DIRECT Diameter-Width (In) 10x? No. Used 1 Screeds (No 4 CFM es. itw.g. See Fan Performance Motor HP 143 R.P.M. 1075 Voes/Phitiz 11511/60 COMBUSTION FAN - Type Camrtugal Drhe -No. Speeds Direct - A .. Motor HP•RPM thee- 2543 Vorweiv S 175/1!80 '' Crated firs) F.L. amps 0.70 T0.40 . Undated (In.) FILTER — Furnished? 'Yes Type Recommended High Veloc' H8 Vet. (No.Size-Thk) Stepped 1 -17x25 - lin. NAT URALGAS MDDELS —CeMr I heat- ing furnace designs am Certified by the American Gas Association for bat natu- ral and LP. gas. Lkmt setting and rating data were estabrished and approved um- de/standard rafngcomdfionsusitgMerl tinNalic nalStandardsInsbtutostandards. SAFE OPERATION — the integrated System Control has sold state devices. which conlnuously monitor for presence of lam% when the system Is in the heating mode of operation. Dual solenoid combi- nation gas valve and regutator provide extra safety. QteC7CNPJITTNG— Durable,cydote tad. heavy gauge Surrtnteed steel beet ex- changer quickly transfers heat to provide warn conditioned *to the structure. Loa energy power vent blower, to Increase efldency and pravlde discharge of gas fumes tothe outside.alows common vent- ing with hot water heater. Oka Tors IS • racy at aae.em eery - rmeetdewbon:am.asm.aatiennt arge Teeter erne ens who 1 nabs redeem' Umrature - Printed In USX 2538675775 Trans A bus :lees of Am etran Standard Companies www.irane.rom General Data PERFORMANCE HEATING VENT COLLAR — Sue on.) HEAT EXCHANGER Type-Fred - Unfired Gaut iF s OR — Win detects. City. -0d Slat L.P. Gas aqyy. — Drill SRe GAS VALVE PILOT SAFETY DEVICE BURNERS —Type Number POWER CONIC — WFMNS AmpaSy M AMPS) Mac Ouercurmnt Protection fartms) PIPE CONK. SIIEON.) WEIGHT Supping (lbs.) /Net (Lis) Mechanical Specifications BURNERS — Muiii -port, in-shot burners will give years01guiet and effident service. Al models can be converted to LP. gas without changing bums -s. INTEGRATEDSVSTEM CONTROL —Ex- ckisivsi j design/ opereti awl program pro- vides total control of furnace limn sensors. blow. r gas valve. flame control and in- dudes set diagnostics for ease of service. AlFI DELIVERY —The muflspeed. *Srect- drive blower motor, wdtt sufficient airflow range for most heating and cooing re- quirements, will switch from heating to cooling speeds on demand from room thermostat The blower doorsatety switch will prevent or terminate ?mate operation when the blower door is removed. (Fan relay and 35 VA control tmnsfonner is stan- dard). 4 Round Alum. steel 20 4 —as 4 - 56 Redundant Two Stage Hot Surface Ignficn Multipart emhot 4 115/1.60 8.2 1c 1/2 HXWxD 41 -3/4 x 1942 x 3012 40x -12x28 142/132 n Celrat Fume herding designs ere aMfied byte Amedun Gas Assoderon Inc. taberamraa v7 Aaaa srmmm In to Sevaeae UP le =Wet For Searle Ware 20M test Ratings aSue be reduced ether* d 4% Os c air 1000 Net abo.e see teat 0 nesse m U.S. Gaenaen S n'S.d ream CO The Mew a siing apeclkatIdss am amomdrivW*, Malone ENO S! Gem; harmer. tmn0aeon• mud empty Mrs ahem PAGE 02 STYUNC — Heavy gauge steel and "wraparound' cabinet construction is used ki the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is com- pletely Fined with foil-faced fiberglass insu- lation. This results in quiet and efficient operation due to the exceUeM acoustical and insulating qualities of fiberglass. FEATURES AND GENERAL OPERA - TION — These High Efficiency Gas Fur- naces employ a Hot Surface Ignition sys- tem which eliminates the waste of a con- stantly burning plot The Integrated sys- tem control lights the main burners Upon a demand for heat from the room thermo- stat. Complete front service atom. a. Low energy power venter. b. Vent proving differential switch. 05 -07 -2007 CHARLES DAY 25500 74 AV S TUKWILA WA 98168 RE: Permit No. M06 -280 4624 S 160 ST TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writinr and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 06/10/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, br Marshall, Permit Technician xc: Permit File No. M06 -280 City of l ukvvila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 License Information License PERFOHA15ORT Licensee Name PERFORMANCE HEATING & A/C INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600601386 Ind. Ins. Account Id 49459900 Business Type CORPORATION Address 1 7649 S 180TH Address 2 City KENT County KING State WA Zip 98032 Phone 4252510356 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/30/1985 Expiration Date 4/29/2007 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date GOWIN, RICHARD L 01/01/1980 GOWIN, CONSTANCE F 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 IV Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond a9 Bond Company Name DEVELOPERS SURETY & INDEM CO Bond Account Number 853803C Effective Date 04/28/2002 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount S12,000.00 Received Date 04/23/2002 • • https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= PERFOHA15ORT 12/12/2006