Loading...
HomeMy WebLinkAboutPermit M2000-043 - CHAMPION WINDOWSCity of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M2000 -043 Type: B -MECH Category: NRES Address: 18436 CASCADE AV S Location: SUITE 120 Parcel P: 788890 -0030 Contractor License No: HOREC * *251QG TENANT OWNER CONTACT CONTRACTOR Status: ISSUED Issued: 03/08/2000 Expires: 09/04/2000 CHAMPION WINDOWS Phone: 18436 CASCADE AV S, TUKWILA WA 98188 ESTATE OF JAMES CAMPBELL Phone: (206)872 -4680 C/0 COLLIERS INTERNATIONAL, 20206 72ND AVE S, KENT WA 98032 ALAN WALIMAKI Phone: 425-821-3333 11447 120 AV NE, KIRKLAND WA 98033 HORECO INC Phone: 425 -821 -3333 11447 120 AV NE, KIRKLAND WA 98033 ******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: FURNISH AND INSTALL 1-6 TON A/C SYSTEM AND DUCTWORK UMC Edition: 1997 Valuation: Total Permit Fee: 7,490.00 59.81 * * * * * ** *art * * * * * * ************************ * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature Date I hereby certify that 1 have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local l aws regulating construction or the perf rmance •• work. I am authorized to sign for and obtain this bi lldi,'s ni it. NA"?.... Date : _r... .. .. '7 gM .._-. ktt )(1) Title: This permit shall become null and void it' the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA Addrfeos: 18436. CASCADE AV S. S+.it.: tenant: C HAMPION WINDOWS ype: - _B -rir cW t�arte1 #t 788890-0030 * * * * * * * * * ** * * * * * * * * * * * * * * * * * * ** rm i t. Conditions: Permit. No: M2000 -043 Status: ISSUED Applied: 02/17/2000 issued: 03/08/2000 ************ * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ** 1 . •, No changes will be mad to the plans uril ess approved by the Ertg1rieer and the 1ukwi 1:a I,Iwi 1.d1rij biv.34i1or1. . All permits, 1 ritj ect.i on records iirid .ap rovecl.- r.31 arty shall be lava i 1 tab 1 e at the ,1 rata s 1 to, rr i or. to the start: Of-any csorn- `s3triacsti cart. 't hu: n,.°:,cio"rumr:rli.s . are tobe maintained and ova i 1, a hr 1 ts` ur�t, i 1 f i rin.'i, i rtspucst 1 car, txpprovi 1 i s granted. " `.All' construction i on tto, h ;, d n i n ' cars t ormtaric:f `wi t.h approved 10art;, and recii1rlam irtts 'Of the .uniform .BuildchgCode 11997: Edition) a i.t�umr�ri csd i� Uniform Mechanical Cads: ( 1997. 1ditit r ), i arid Wtasah 1 rijt.ori Stt ti Eriergy Cud 01997 Edition) :,N441idiWOf Permit,. "`ihc: issivaricse' o;P a permit 'ort tap yrovul of z,n, l ris,4 irl Fr i:at 1ar a, und uonpata.9ers shall not be con-, f truvcio tip a permi t for ', or :,an approval of, ary.: v i v I j,t yr t*rty�, xt.t P thi `: prov i a i t rii�i (3 f i.hic °ills i 1 Clri rid code or of any,,_ r)t.hv :f r•diritarlc:e of the .:Juriadi;c:t.icari. ;.t No permits prt:iium1nri t ra ,!J1vi ?.Mithvr.i�t y to :vicalatp or. r:` nric;t:his-;provisaicarts; Of t h1'�! rsocit1 {�Jha 11 be ua 1 i r1 t " X B. Man af c;t:urf r n irwt:aa11tai,ic ri 1mntr�unt1orw• rr;quired on nitre i or :Chu hui�ici1rij, i.riupt:cai:car5s .ivit;w. CITY OFTf'WILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Name/Tenant: Value ofiyeqchanical Equipment: Tax Parcel Number: Site Address :4444optic.5G OE Date: City 11)1641L-1.4 e/- . • I .r 1 a • Property Owner: Phone: ( �s"�� Phone: ( ) Street Address: r Address: 1, tp ve, N e. . City State/Zip: Fax #: ( Contractor: 21.4 ea— i G • Phone: ( t ) S 621,4433 Street Address: ` 144 I ZOO" / - - lit � t p Fax #: ( ) 6247-01.475 Contact Person: Phone: (42.5. ) € Z1 -��j�� Street Address: l 1 I 120 . ,v,e City Scat� :: le.1 eiLLID,IL�R'• 3� Fax #: ( ) $20 -,-r5 MECHANICAL PERMIT. REVIEW AND APPROVAL REQUESTED: (TO BE FILLED our BY APPLICANT) Description of work to be done (please be specific): rAc Current copy of Washington State Department of Labor and Industries Valid Contractor's License, If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H•4, "Affidavit In Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter Irom the property owner authorizing the agent to submit this permit application and obtain the permit will bo required as part of this submittal. l HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PER JURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. JUILDIN;FAriIV I T Ag7jErEll GENT: Slgnatur If rilitill I Date: �,� Print name: , GO Set , Phone: ( �s"�� Fax 1: ( ) 8 r Address: 1, tp ve, N e. . City / State/Zip: 1`,f'rs� y q$083 Expiration of Plan Review • Applications for which no permit Is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shalt be extended more than once. pat pll t acre ed; Date a catio • . res: MP WO 11/2/99 nsech perndt.doc App 'cation taken 01. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal ✓ S Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 . H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies.with the efficiency ratings and 'other applicable requirements of the Washington State Nonresidential Energy Code: Structural engineer's analysis is required for new and the replacement ofexisting roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal S hn►►11,►1 Ill'gti►r f'►►►►V►►1" New Sln le Famil Residence Heat loss calculations or Form H•6. Equipment specifications. Chan e•out or replacement of existingmechanical equipment Narrative of work to be done Includin modification to duct work. 1 Installation of Cal Fire - lace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney Is In safe condition, NOTE: Water heaters and vents aro included In tho Uniform Mechanical Code — please include any water • heaters or vents "being installed or replaced. t l y* * * * *yy * * * * *yy *y y* * * *y. **y *y * yyy * y * * * *y * *yy *y ** * * * ** yyR *yyyyy * CITY OF TUKWILA, WA '* W ` C TRANSMIT * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * * * * * ** * * * * * * * * ** * * * ** ** TRANSMIT Number: R9800247 Amount: 59.81 03/08/00 14 :37 Payment Method: CHECK Notation: HORECO INC /nits WER Permit No: M2000 -043 Type: B MECH MECHANICAL PERMIT Parcel . No: 788890 -0030 Site Address: 18436 CASCAOE AV S Location: SUITE 120 Total Fees: 59.81 This Payment 59.81 Total ALL Pmts: 59.81 Balances .00 * * * * * * *** * * * * * * * * * * ** t * **r *** * * * * ** * * * * * * ** *fir ** *fir* *fit * * * * ** ** ** *** Account Code Description Amount 000/345.830 PLAN CHECK - NONRES 11.96 000/322.100 MECHANICAL - NONRES 47.85 2261 03/09 9717 TOTAL .9.8i: A INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Project: :. ......_ i .... Type of I .Mrr ... Mill I Adore s; A Specia instru . • called; ons: Date wanted: 40 Requeste . Phone: Approved per applicable codes. Corrections required prior to approval. © $47.00 REINSPECTIO If REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd. Suite 100. Call to schedule reins s action. INSPECTION RECORD Retain a copy with permit INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818: (206)431.3670 PERMIT NO. Protect: / T pe of inspect . Address: / . a" called: Special instruc ions: 6 : 1>t) Date wants ' ,m Requester: Phone: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: $47.00 REINSPECTION ' E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd. Suite 100. Call to schedule reins ection. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431-3670 Proje : Alt .. .. 0 1 (J . 4 ■ A 1., A� Ty.ae of inspec • A i Address: i A") PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: _M2000 -043._ DATE: 2 -17 -2000 PROJECT NAME: CH _ ON AMPI_ WINDOWS XX _Original Plan Submittal Response to Incomplete Letter # _. .._.Response to Correction Letter # _Revision # After Permit Is Issued DEPARTMENTS: g ilk din Div' on Public Works Fire f�revention AW 2..22'& Structural ❑ Planning Division Permit Coordinator PETERMINNATION Q COMPLETENESS: (Tues., Thurs.) DUE DATE: 2 -22 -2000 Complete 21 Comments: Incomplete Not Applicable El TUES /THURS ROUTING: Please Route ❑ Structural Review Required �❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE 3- 21-2000 Approved [.1 Approved with Conditions, Not Approved (attach comments) Ej REVIEWER'S INITIALS: DATE: CORRECTION DET€RMI MJ N: Approved ❑ DUE DATE Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWER'S INITIALS; DATE: WRROUTE.QOC 5/99 City of Tukwila John w Rants, Mayor Fire Department Thomas P. Keefe, Are Chief February 25, 2000 Fire Department Review Control *42000-043 (511) Re : H.V.A.C. at Champion Windows - 18436 Cascade Avenue South Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. unite rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required'. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2 000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic 'shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 2. Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) In areas that are not continuously occupied, automatic smoke detection shall be provided at each control unit(s) location to provide notification of fire at that location. (NFPA 1 -5.6) The installation of wiring and equipment shall be in Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax: (206 ) 5754439 City of Tukwila Fire Department Page number 2 John W. Rants, Mayor Thomas P. Keefe, Are Chief accordance with N.'.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72 -1- 5.5.4) 4. When the control panel door to the room shall have which reads "Fire Alarm" or Ordinance #1742) is located inside a room, the a sign with one -inch letters "Fire Alarm Control ". (City Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 5. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) adopted Fire Codestdoesanotoimplylapproval the such condition or violation. imply approval truly, The Tukwila Fire Prevention Bureau cc; TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone• (206) 5754404 • Fax (206) 575-443i Fob- 17'- 00'12:58P P.02. Muck And hispluy t'drthicute DEPARTMENT OF LAROR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT SPECIALTY •• RIGIBT .: ;0, . • . EXP . DATE CCARAA MORSIC«4;251QO 09/01/2000 s! ECTIVS.DATE 11/07/1975 HOMO. INC 11447 120TH AVE NE KIRKLAND WA 98033 -4598 104Il-092400 (01971 ---' -- f ctnth AnJ Di,olay Cent OW ---- -' REGISTERED AS PROVIDED BY LAW A� CONBT CONT SPECIALTY MIST. 0 *XP. DATE CCASAA HORSCIP*251Q0 09/01/2000 srvECTxv1 DATX 11/07/1975 HORUCO INC 11447 120TH AVII NIII, ' KIRKLAND WA , 98033 -4598 Plcue Remove And Sign Identification Curd Before Placing to 13i11t'old Slpnocuro Iuvcd by DEPARTMENT OP LABOR AND INDUSTRIES Wllt 11.131») N? 7! _- . ,w ,w, „ ' , MUNN ioNL P! '3AY73OVOSYO 1131N2Q SS3NISfi8 3Q.VOSVO l:131OV1 1:10d 1N3W3AOadWI 1NYN31 wwioos1011■111•111111•1111•11111111111as1111r1•111•111•••• 0 i o vS o Z Fz y �� EK I(7' 0 Z z`J�` i °w OP o ao w a h 1i P p2`' c <�<c�SSi 1 � � � �� ��Zi�I�- ���+��gy�+ d �g�� �mWWi��" tY-1 Wso9`5 -�.� �� �� c°�1a� o i 5 i g iii o05�o go d adi nE ii vi ov�v° l i �°O4r§ Sy"b'i 33833 i G i l4 1 cOiz'' i1 #. a JK Sw gb:c1 A F 4 .., c S At m c 5 3 ya U 1 1 G K =K =Z W1 �W 5 1 Z ril6 § K KT O °1- ''i. < Z O P�.: U30 g _ A 3 o z � NW dibilliNiiihilLigliggisddiggighliiiiiii ii 4i ' fi�i IT « ti ci c.f cS cAya Jag vj d hc��Y� aG}��QyL o �, �..I ggi C}Q�� it �W Rc a`iz yeti Coax J pJpQ y g ^Sic�`�i1�C6oV�.�tY��� E]�S�SO�� �i.�.1��Ci•.� 41�� �. �.. letrf.�:l'.�.:��.(�G'���a:�i�.. C5 c3i3 t�G Utz iS�:Ea'i�i 0 N z 7 v, w a m N czm �d vi3 �� z rn �3 I .` .,r z,-, 2 ' 2 M Pang ,J N WI! U 24 1 IV w r W d W �' N d d t ,- ' ,- w i . a d ... Pg. iv V' 'v W r d d v wyn in 8 v a w i 1 W W Z w WW F O t e de.3 .�, g e o §o Wao L 0 1 „z i EMONo Ei ts, 401"; 04 415 8 11) 1 0 ig L° a P w cp z .9 G ai is M w N a c . iiviseeina dF sommanussramaes NOIJNIHSYM S 3A0/ .30YOS 4 wousu 5 " o N � . a31N3O SS2NISf18 3QYOSYQ 8310V19 - .L16.4 10110L1411 JANE E VE (TYP.) otl• gg ,£ d ps 11111 q I 1 v •••• 1lw•i.■••w1111•1111 •••••••••••••••••••••••••• wd 8P6 66/12/21. e*p.21- dInIVH2; Date; • 225 N. 30th Street Suite 300 Tacoma, WA 98403 Oki-Town MistOrIcalDIstrict 2531383-24Z2 1531303-2572 FAX Project 12SCf# Qit.'41( OOP/CS/ // No. 2t..)47.0.Y0, Z. 0 Subject 41-27A-LciAk Ai I Phone With/To Fax Address 0 Faxed Pages gx`i' bF:cf2.: .. • IA a'at C, /544Ar4. `Aitzt-1....,',$ .7.c . • . . P '227 0 Page ot o o Calcutations 0 Fax Memorandum Meeting Minutes Telephone Merno . , 2.i( ID DF4tiz T Tr6P r - "7"ro 70,774 ar .3;(2 r.s g .sicc `2)2,(Lf,46 sg.el &7—d,„,,.. CITY Of TUKWILA APPROVED U ULDG r), • PlOONIVITI 0MoFTu-K*14A; PERMITCENMER-: If this does no,. r,-afit with your understanding, please contact U in writing within seven days. THANK YOU. • Description joists OSSM: Using ngyn ra Date: 8 :81 AM, 26 JAN 00 Descriptton : 11C01111: Mufti -Span Timber Beam fi General Information Fb : Basic Allow Spans Considered Continuous Over Support Fv : Bate Allow 900.0 psi 96.0 psi Elastic Modulus Load Duration Factor 1,800.0 k& 1,000 Timber Member Information Description Span Timber Section Beam Width Beam Depth End Malty Le: Unbraced Length Mamba Typ Loads Lwe Load Used This Span 7 taco :Ys, y3.500 7.2'0 I'cn • Pin 0.00 Sawn Dead Load Live Load Head Load Uve Load Start End Silt gift t ft 8 Yes 7S,00 8'700 2.400 3.coe 'results Mnwx g Cr* inns -k al X R 5..*3 Mawr fa Left End in-k u.0 Max fa Right End In-k • 0.0. tb -, Actual psi $318,4 Fb • Allowable Asst 1, Q.0 Bending Oil. Shear g Left k 0.76 S hear it Right ' k l 0.7 tr fir : Actual f 40.e . Fv a Allowable : • � 95.0 1 Skt4o, U,ti Reactions & Deflection nt. ®,Left LL la Left Total U Leif 0L fa Right LL Right Total Rigid Max, DeMction k k k k k k in 81 0.38 0,37 0,76 0.37 0.76 0,200 5.00 Query Values Location Moment Shear Deflection R In-k tbs • 0.00 0.0 • 0.s 6.00 FtEDENED MTV OF TUKWIL PERMI.,P r „ItiNI iH (c) 1983 -98 ENERCALC k_\structurailyr .ecw: KW- 00022M Ver 5.0,8, 15 -Jul -1988, wu 2 Prriect CA6akbr. - f604"dgSJ 7f No. LSD Lf Z 0 (_f Pam of Subject, f¢'/1 Phone ❑ Calculations U Fax Fax # El Memorandum Address .._.:,�_ ,_ # Faxed Pages - ❑ Meeting Minutes [J Telephone Merno With/To i ay: Copiei td: 2215 N. 30th Street Stilts 3Q0 • Did Town • Historical District 253/3.24`2 253/383-2572-FAX j— I i °IC:7 it th1; ci,,Qt_iE?' -r $` ote 7671 9 Date •• ^a Fe of L► Paaes .�. 1 C®.Ctant- Co.c........, Phone- tr Phone a %, N L.! Pax = Fax dt n days. THAtikeniliT C N€ F i °x SINGLE PACKAGE AIR - COOLED CONVERTIBLE SERIES AIR CONDITIONERS DDHB 036, 048, 060 & DBHB 072 DHUC 036, 048, 060 & DBUC 072 3, 4 AND 5 NOMINAL TONS (10 SEER) 6 NOMINAL TONS (9 EER) RECEIVED CITY OF T'J.KWILA Dom urn flIMMTPM 53411 .O`-Tvt I_ (698) DESCRIPTION The DHB and DUC units are convertible single package air conditioners with a common cabinet and a common roof curb for the 3, 4, 5 and 6 ton sizes. The units were designed for residential, light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. .I uryfts are salf— ..on4talned arxi assembled on rigid full perimeter base rails with fork lift slots on three sides and holes for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to provide fora quick and easy field installation. The units are available in cooling only and cooling with gas heat. Electric heaters are available as field- installed accessories. The cabinet is constructed of galvanized steel, painted with long lasting, durable, and aesthetically pleasing power paint. Paint finish meets 750 hour salt spray tests per ASTM -B117 standards. All models include a 5 -year limited warranty on scroll compressors and electric heating elements, a 10 -year limited warranty on gas -fired heat exchangers and a 1 -year limited warranty on all replacement parts. FEATURES COMMON FOOTPRINT/COMMON CARNET - All model sizes and configurations share a common cabinet and a common roof curb. The installer has the flexibility of setting one curb and placing the proper tonnage unit on that curb after the internal load has been determined. He can even decide between gas or electric heat after the curb has been set.h HIGH EFFICIENCY - AO units have a high cooling efficiency, and gas / electric models have a minimum AFUE of 80 %. All efficiencies exceed legislated minimum levels and provide low operating costs. CONVERTIBLE AIRFLOW DESIGN - Both the side and bottom duct openings are covered when they leave the factory. If a side supply / side return is desired, you simply remove the two side duct covers from the outside of the unit and discard them. If a bottom supply / bottom retum is desired, you simply remove the two knockout panels from the base of the unit and discard them. No panel cutting or swapping is required! Convertible ai, now design allows maximum field flexibility and minimum inventory Economizers may be used on either bottom and side duct applications with no modifications required. FACTORY - INSTALLED OPTION - Adjustable belt -drive blower is available on all models from the factory to provide maximum air flow flexibility. FIELD- INSTALLED ACCESSORIES - Accessories were designed for quick and easy installation. i ne motorized damper and economizers simply slide in, and electrical connections are made by modular plugs. Electric heaters mount easily, and knockouts are provided in the intemal partitions to connec=t the elements to the control box single point kit. The motorized air damper includes a slid - in/plug -in damper assembly with a rainhood and filters. The outdoor air dampers open when the indoor fan motor is energized. The damper is capable of 530.18-TG1 RATINGS CAPACITY RATINGS - Cooling / Elect'ic Heatin MODEL ARI RATINGSI NOMINAL ELECTRIC HEAT CAPACITY3 (KW) STANDARD CFM COOLING CAPACITY 801 67-95°F SOUND RATING2 (rihalsl COOLING CAPACITY 80167 -95 °F I CCM, AM! ' .:,1 .,,to DHB036 36.0 10.00 9,10 82 5, 7, 10, 15 &20 7, 10, 15 &20 10, 15 &20 1.300 DHB048 47.4 10.00 :::;;; ; 82 5, 7, 10, 15 &20 7, 10, 15 &20 10 ' 15 &20 1.700 DHB060 59.0 10.00 OE 1€1 82 5 7,10, 15,20 & 30 7,10,15 20&30 10,15, 20&30 2100 DHB072 72.0 - 9.00 84 5, 7, 10, 15 20 & 30 7, 10, 15, 20:30 10, 15, 20 8130 2.400 GArAL I 1 Y KAI INU - UooliGig 1 U8s Heating 1 GAS HEAT CAPACITY STANDARD CFM MODEL ARI RATINGS COOLING CAPACITY 80167 -95 °F SOUND RATING2 (dbels) INPUT (MBH) OUTPUT (MBH) AFUE ( %) S.S.E. ( %) TEMP. RISE ( °F) GAS LINE SIZE (in. OD) MBH SEER EER DUC036N050 DUC036N100 36.0 36.0 10.00 10.00 ................. ................... 910 < 82 82 50 100 40 79 80.9 80.5 81.6 80.8 15-45 40-70 1, 12 1.300 DUC048N075 DUC048N125 47.4 47.4 10.00 10.00 900 $. ; Y 82 82 75 125 59 99 80.9 80.3 81.6 806 25-55 45-75 1/2 92 1.700 DUC060N100 D COSON125 59.0 59.0 10.00 10.00 `> 1?0 5.110 82 82 100 125 79 99 80.5 80.3 80.8 80.6 25-55 35-65 1/2 1 ?..100 DUC072N100 DUC072N125 72.0 72.0 - - 9.00 9.00 V 84 84 100 125 79 99 80.5 80.3 80.8 80.6 25-55 35-65 l/ 1/2 2.400 1 RatIngs are in accordance with ARI Standard 210. 2Sorxrd ratings are In accordance with ARI Standard 270. 3ileatars are available as accessories - e/ with single point pow r supply. SEER = Seasonal Energy Efficiency Ratio - the total cooing output in BTU's during a normal annual usage period br occang d riled by the toad electric polrsr input n w�Khaus aus i A seas period EER = Energy Efdency Ratio - the cooling capacity in Btu's per hour (Stull) divided by the power input in watts at any fsven asp a ream aonaiuons, a,ass.ed n bilk; pw wad (B < UHM01). AFUE = Annual Fuel Utdlzabbn Eff' y - *do mino:I in accordance with DOE test procedure. S.S.E. = Steady Stale Efficiency. (Percent Output). Not ARI Listed. PHYSICAL DATA - BASIC UNITS MODELS DHB/DUC 036 048 060 12 x 10 072 12 x 11 EVAPORATOR BLOWER CENTRIFUGAL -12 x 10 'Dia. x Wd. in.' 12 x 10 FAN MOTOR HP 1 (DIRECT - DRIVE) '� 3�'4 1 1 FAN MOTOR HP 11/2 (BELT-DRIVE) 11/2 11/2 11/2 EVAPORATOR COIL ROWS DEEP 3 3 3 4 FINS PER INCH 13 13 13 13 FACE AREA (Sa. Ft.) 3.6 4.3 5.1 5.1 COMPRESSOR TYPE HERMETICALLY SEALED BRISTOL SCROLL CONDENSER FAN PROPELLER DIA. (in.) 24 24 24 24 FAN MOTOR HP 1/4 1/4 1/4 1/4 NOM. CFM TOTAL 3.400 3.400 3.400 3.300 CONDENSER COIL ROWS DEEP 1 1 1 2 FINS PER INCH 16 16 22 16 FACE AREA (Sa. Ft.) 17.1 17.1 17.1 16.7 AIR FILTERS (SEE NOTE) QUANTITY PER UNIT (15 "X20 "X1 ") 2 2 2 2 QUANTITY (14" X 25 "X 1") 1 1 1 1 TOTAL FACE AREA (sa. fta 6.3 6.3 6.3 6.3 CHARGE RREFRIGERAN rr a R-22 (IbsJoz.) 5/8 , 6/8 1 6/8 1 10/0 n .oGi V7�v OrrY OF TUKW'I STATIC RESISTANCES DESCRIPTION I 6; 530.18 -TG 1 RESISTANCE, IWG E ofnizer Electric Heaters' Bottom Duct Connectio 5 -15KW 20 - 30 KW CFM Iola! iv 1 1 •.1./ ��•1 11a /•1 ��1 /a1 ��1 1•a 1�1 •1•Ia1 0.07 0.08 0.04 0.05 0.06 0.07 0.09 0.06 0.08 0.06 0.07 .•.•. 1 °.11 1 r, 1 0.08 0.11 0.13 0.07 0.08 0.09 0.11 0.09 0.10 0.15 0.10 0.13 0.11 Deduct there resistance values from the a;NUM; In w ss i i ave Psio'm a /Add Tim thew resistance values b the av lie static reelsta nce in the respective Rower Perbrtnar1oe Table. aTO pressure thni the economizer is greater for 1009E outdoor ale then for 100% rim sir: If the resistance of the return elr duct system is Ises tun 0.25 IWO, the unit el deliver less CAA during full economizer operation. 0.17 0.20 0.23 0.12 0.14 0.16 0.15 0.17 0.20 0.12 0.14 0.18 0.26 0.19 0.23 0.19 0.30 022 0.26 022 MOTOR AND DRIVE DATA - Belt - Drive Blower POWER SUPPLY BLOWER MOTOR' ADJUSTABLE MOTOR PULLEY FIXED BLOWER PULLEY BELT MODEL RANGE (RPM) HP RPM FRAME SERVICE PITCH DIA BORE PITCH DIA BORE PITCH DESIG- 1.3 4.4 28.2 45 SIZE FACTOR (in) On.) (in) (in.) LENGTH (In) NATION DHB / DUC 036 790 - 1120 11/2 1725 56 1.15 2.4 - 3.4 1/8 5.7 1 37.3 A36 DHB / DUC 048 790 - 1120 11/2 1725 56 1.15 2.4 - 3.4 7/8 5.7 1 37.3 A36 DHB / DUC 060 850 - 1220 114 1725 56 1.15 2.4 - 3.4 u/8 5.2 1 37.3 A36 DHB / DUC 072 ` 900 - 1250 11 1725 _ 56 1.15 2.8 - 3.A A 7/e 5.2 1 37.3 A36 'AI motors have solid beers end are krherenty protected These motors min be selected b opersls Yro thdr service factor because toy are Waled in tie moving ale, wolfram of rely heeling dwtce. ELECTRICAL DATA - Basic Units with Direct -Drive MODEL DHB DUC POWER SUPPLY VOLTAGE LIMITATIONS (SEE NOTE 1) SCROLL COMPRESSOR COND. FAN MOTOR „ ' Fes. SUPPLY AIR BLOWER I MOTOR, MINIMUM CIRCUIT i AMP CITY MAX. FUSE SIZE, (SEE NO cz) MAX. HACR BBREAKE °n SIZE, MIN. MAX. RLA LRA COMPRESSOR 208/230 -1-60 187 253 18.0 105.0 1.3 4.4 28.2 45 45 036 208/230 -3-60 187 253 11.4 90.0 1.3 4.4 20.0 30 30 208/230 -1-60 460 -3-60 414 504 6.2 45.0 0.8 2.2 10.8 15 15 208/230 -3-60 575 -3-60 518 630 5.0 36.0 0.8 2.2 9.3 15 - 460 -3-60 208/230 -1-60 187 253 24.4 140.0 1.3 5.0 36.8 60 60 048 208/230 -3-60 187 253 14.1 105.0 1.3 5.0 23.9 35 35 208/230 -1-60 460 -3-60 414 504 7.1 55.0 0.8 2.2 11.9 15 15 208/230 -3-60 575 -3-60 518 630 5.6 44.0 0.8 2.2 10.1 15 - 460 -3-60 208/230 -1-60 187 253 28.9 165.0 1.3 6.6 44.0 70 70 060 208/230 -3-60 187 253 16.0 125.0 1.3 6.6 27.9 40 40 208/230 -1-60 460 -3-60 414 504 8.0 67.0 0.8 3.3 14.1 20 20 208/230 -3-60 575 -3-60 518 630 6.4 50.0 0.8 3.3 12.1 15 - 460 -3-60 208/230 -3-60 187 253 20.3 146.0 1.3 13.8 4c 50 50 072 460 -3-60 414 504 10.2 73.0 0.8 11.2 2 25 25 : 1. Ulfkzaton Range A' in accordance with ARI Sled 110 2. Duel 4ms type • �i`vi• 1 niiiL U14 a M - tsaslc Units wim belt -Drive VOLTAGE SCROLL COND. SUPPLY MAX. MAX. MODEL DHB DUC POWER SUPPLY LIMITATIONS (SEE N OTE 1) COMPRESSOR FAN MOTOR, AIR BLOWER MINIMUM CIRCUIT FUSE SIZE, HACR BREAKER MIN. MAX. RLA LRA FLA MOTOR, FLA AMPACITY (SEE NOTE 2) AMPS SIZE, AMPS 208/230 -1-60 187 253 18.0 105.0 1.3 5.3 29.1 45 45 036 208/230 -3-60 187 253 11.4 90.0 1.3 5.3 20.9 30 30 460 -3-60 414 504 6.2 45.0 0.8 3.1 11.7 15 15 575 -3-60 518 630 5.0 36.0 0.8 3.1 10.2 15 - 208/230 -1-60 187 253 24.4 140.0 1.3 8.6 40.4 60 60 048 208/230 -3-60 187 253 14.1 105.0 1.3 5.2 24.1 35 35 460 -3-60 414 504 7.1 55.0 0.8 2.6 12.3 15 15 575 -3-60 518 630 5.6 44.0 0.8 2.0 9.9 15 208/230 -1-60 187 253 28.9 165.0 1.3 8.6 46.0 70 70 060 208/230 -3-60 187 253 16.0 125.0 1.3 6.0 27.3 40 40 460 -3-60 414 504 8.0 67.0 0.8 3.0 13.8 20 20 575-3-60 518 630 6.4 50.0 0.8 2.4 11.2 1S'il~CE ED - 208/230 -3-60 187 253 20.3 146.0 1.3 7.3 34.0 C1721 OF Tun 072 i 460 -33-60 414 504 10.2 73.0 0.8 3.7 17.3 25 25 575 -3-60 5j8 630 8 2 i 58.4 0.8 2.8 13.9 20 ' ___ _ -,- - 0 UNIT DIMENSIONS (DHB AND DUC - 3, 4, 5 & 6 TON) FIELD—SUPPLIED DISCONNECT SWITCH LOCATION ( units) FILTER ACCESS CONTROL BOX ACCESS BLOWER ACCESS dig 32.518 DHB UNITS 3 -6 TON SCROLL COMPRESSOR ASS mecum MEAT ACCESS Y4' PVC FEMALE COND. DRAIN (See O. 'A') A. WNTEiNG L�f4EIf fees Dsta!!'0') wirrom supPLY & RETURN AIR OPENINGS (SEE NOTE) t) - POWER WIRING ENTRY A - CONTROL WIRING ENTRY All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. CONTROL FIELD- SUPPLIED BOX DISCOMNECT SWITCH A C LOCATION \ (Dlr- D!tve) ALTER ACCESS SLOWER ACCESS UNIT BASE WITH RAILS Shown eepsreewy` M Sure is bottom duct openings fund power connection Wagons. NOTE For curb-mounted units. rear to the duct hanger dimensions of the curb for the proper size of the supply and return sir duct connections. VENT MR CUTLET HOOD CONDENSER SCROLL COMPR. ACCESS CosieusnoN MR wL.ET HOOD 4318 32.518 DUC UNITS 3 -6 TON AC MEAT ACCESS / GAS SUPPLY ENTRY 82414 - (1/2' NMI AT GAS VALVE) I} 2-142 ly 1 314' PVC FEMALE COND. DRAIN (Sit DstaN 'A') A. 8 WIRING ENTRY (See Detail 'B") BOTTOM SUPPLY & RETURN AIR OPENINGS (SEE NOTE) - AMER WIRING ENTITY A - CONTROL WIRING ENTRY 6318 D GAS SUPPLY ENTRY (th' NPTI AT GAS VALVE) UNIT BASE WITH RAILS Shown separatsiy to illustrate bottom duct comings, pow and gas piping connection locations. NOTE: For curb-mounted untie. MN to the duct hanger dimensions 01 the curb lor the proper slzs of the supply and return sir duct connections. , a67 :r;•,ai: s.0•7: UTILITIES ENTRY DATA HOLE KNOCKOUT SIZE (DIA.) USED FOR A 7/8" • Control Wiring (Side or Bottom)" Power Wring (Side or Bottom) Gas Piping (Front) Gas Pipin (Bottom) B C D 2" • 1 -5/8" 1 -1/2" *Knockouts in the bottom of the unit can be located by tike slice in the insulation. **Do pot remove the 2' knockout ring. CLEARANCES Front DHB Units 24" DUC Units 32" Back 12" (Less Economizer) 36" ((With Economizer or Fixed Air/Motorized Damper) Left Side Titer Access 24" (Less Econoizer) 36" (With Economizer) Right Side Cond. Coil 24" Below Unit 0" Above Unite 72" (For Condenser Air Dischar•e 1 Units may be Installed on combustible floors mode from wood or days A, B or C roof Covering materiel. 2 Units must be Installed oudoors. Ova harging strictures or shrubs should not obstruct cordeneer air discharge outlet NOTES: 1.21111112111118 Units and ductwork are approved for zero clear- ance to combustible materials when equipped with electric heaters. OUG.B: A 1' clearance must be provided between any combustible material and the supply air ductwork for a dstance of 3 feet from the unit The products of combustion must not be allowed to accumulate within a confined space and red, ate. Locate unit s© that the vent air oultst h Is • Three (3) feet above any forced air Inlet located within 10 horizontal feet (excluding those integral to the unit). • Four (4) feet below, 4 horizontal feet from, or 1 foot above any door or gravity air inlet Into the building. • Four (4) feet from electric meters, gas metros, reguattors and relief equipment RETURN AIR SUPPLY AIR CONDENSER AIR RECEIVED OtFOQi_frw t izer) , (Econom (ro ROOF CURB DIMENSIONS - (DHB and DUC - 3, 4, 5 & 6 TON) BACK OF UNIT RETURN' AIR DUCT SUPPORT RAILS SUPPLY` AIR 2' TYP.—•>, 530.18-TG 1 SCROLL COMPRESSOR AND CONDENSER END OF UNIT 19 -117' 37 -1/4' DUCT SIZES: Supply Air -19' x 19' Return Nr- 19'x19' FRONT OF UNIT 'Supply and Return Nr (including duct support ram) shown are typical for Mart duct applications. For location of Nal= duct applications (on bask of unit), refer to Unit Dimension details. COMPONENT WEIGHTS AND CENTER OF GRAVITY BASIC UNIT 1 OPTIONS/ACCESSORIES DCG SIZE (heat) UNIT WEIGHT• (.) CORNER WEIGHTS° 1 (ocaton, lbs.) DCE UNIT WEIGHT" (lbs.) CORNER WEIGHTS° (; ��,,, IW) DESCRIPTION WEIGHT (om') "A" "B" "C" "D" "A" "B" "C" "D" 036 (40 Mbh) 625 180 172 133 140 036 565 160 157 123 125 ECONIMIZER 50 036 (79 Mbh) 635 180 177 138 140 048 615 173 170 135 137 MOTORIZED OUTDOOR AIR DAMPER 26 (60 0 Mbh) 675 193 185 145 152 060 640 180 177 140 143 (99 048 ) 685 193 190 150 152 072 720 171 196 189 164 ELECTRIC HEAT (nom. KW) DCE only K 18 060 (79 Mbh) 700 200 192 150 158 • Weight - unit + Economizer. s CORNER 'IX 10 -15 KW 23 (9 060 Mbh) 710 200 197 155 158 KW 28 072 (79 Mbh) 775 186 209 201 1798 MOUNTING 92 072 (99 Mbh) 785 186 214 206 179 AIR DAMPER 10 BELT-DRIVE BLOWER 5 CORNER 'A' DIM. X 3 -5TON,[ 6TON 19 -3/4" {{ 22" 40-3/4" I 44" BACK OF UNIT 447/8 B2l/4 APPROXIMATE CENTER OF GRAVITY FRONT OF UNIT CORNER "B' CORNER CONDENSER END OF UNIT COIL REOEIVED cm,* * OF TUKW1LA