Loading...
HomeMy WebLinkAboutPermit M2000-093 - BIRCHCREST APARTMENTSM2000 -093 Birchcrest Apts. 4030 S 140 St EXPIRED AUG 3 o 2001 City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M2000 -093 Type: B -MECH Category: NRES Address: 4030 S 140 ST Location: Parcel #: 736060 -0465 Contractor License No: UMC Edition: 1997 P e r m i t Centerluthor i ted Signature MECHANICAL PERMIT TENANT BIRCHCREST APARTMENTS 4030 S 140 ST, TUKWILA WA 98168 OWNER BIRCHCREST APARTMENTS PO BOX 925, EDMONDS WA 98020 CONTACT JAMES K LEE 8200 5 123 PL, SEATTLE WA 98178 :k k**** k** kle k k *** ** *** k ** k*** k ** k k k*k ** * **** ** k*:k k*•k* * k* k • k* k* Permit Description: INSTALL -6 DRYER VENTS & 1 LAUNDRY ROOM EXHAUST FAN VENT Valuation: Total Permit Fee: kick •k*-k k*"k ,i4 k ** k * . k h*k•kk•k* *k *•k•kk•k *k*kk:k ** Irk kkk•kk•kk * ***A******* * *kkk *k Dat (206) 431 -3670 Status: ISSUED Issued: 06/08/2000 Expires: 12/05/2000 Phone: Phone: 206 - 772 -1684 porin 200.00 83.75 1 hereby certify that I have read and examined this permit and know the same to.be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. 1 am authorized to sign for and obtain this building permit. Signaturej Date: d 0/870 Print Name: ZS14MTS . Title: OW/W. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA Address: 4030 S 140 Sr Suite: Tenant: BXRCHCREST APARTMENTS Status: ISSUED Type: 0-MECN t Applied: 05/08/2000 Parcel 4: 736060 -0465 Issued: 06/08/2000 *, - k'k* A* kA1*• k**• A**** k* k •kA•k * *A *A*•A *- k kk * *Ahk#k•kk*kh *•k k* ***k*•*k *hk4 Permit Conditions: I No changes will be made to. the .plans :.. unless approved by the Engineer and the Tukwila Building Division. 2, All permits, inspectitin " records, and approved plans shall be available at the job site ;prior to the start of any con- struction. These docdmonts are to be maintained and avail- able until .final inspection approval is granted. All construction .to ,b e done in :conformance with apps o ed plans and requ i ren#er3ts of the lin i f orM Eau i l d i ng :Code (1997 Edition) ; as : amended, Uniform Meehan i ce 1 Code (1907 E d i t i o n ) , Permit No: M2000-093 and Washingtor , State Energy Code (1997 Ed i t i'un) . 3t Ve1idfty of Permit. The issuance of a permit'or approve plans,`/ specifications, and computations shall not be' con - , strubd tobe a permit for, or an approval of any violatio of *4 o f the provisions s of ;the b u i l d i n g code or of eriy, oche ordinance of the jurisdiction.. No permit presuming g i ( i authority to ; i o 1 ate off' canco1, . the pr.cry i s i ons of th i. cods P A l l bp` vo 1 i•d. Manufacturers installation instructions requ i rend on s i td fa b u i l d i n g i n specttora rev i rpw Project Name/Tenant: ..)Ajs k- Lv�- Value of Mechanical Eciu Signature: �c'c) --� Site Address : ,{ 3o S 140 ?s 54_ i V c< iyii_ Cit s p: Ta7 et c 0463 Property Owner: k_ L9242_ Date: ¶i pe.,.) Phone: ( ) 7 77z_ 1 G -- Street Address: TO . g' R City State/Zip; hJa /ro 5 �Z Fax ( ) a06 777_ Phone; ) c wc ) 777__. (6are+• 14 '' - 4- . Contractor: atkwa.(z --. __ � Street Address: City /StatdZt. F City State/Zip: Fax #: ( ) Contact Person: Phone: Street Address: .42— Ci S tate/Zip: K. Fax #; ( BUILDINGVWNER OR AUTHORIZEDACEN r .} . , .: Signature: 44 - _ • (... * ..., Phone. ( ) Date: ¶i pe.,.) Print nam Fax N. ( ) Address: g 490 3 * 17 30r > � City /StatdZt. F f!V 4_ ' $"f 7s CITY OF T( :WILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 N `r Project Number: Permit Number: Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (tO RE FILLED OUT BYAPPLICANI) Description of work to be done (please be specific): `. ► `. I5 IMO SI Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this licensee will be required before the permit Is issued OR submit Form H•4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agentz If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will bo required as part of this submittal, I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review • Applications for which no permit is issued within 180 days following the date of application shalt expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once, p e appli ion ac e zed: • 11/1/99 nlech pe n ll doc Date • licati.• expires: • U © cow 0u. W 0 O 8 �W Z� 81 D E � W � U �N ✓ ■ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal RESIDENTIAL Two complete sets of attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code -- please include any water heaters or vents being installed or replaced. Slli)u)ittal Requireme►nls New Sin: le Famil Residence Heat Toss calculations or Form 11.6. Change -out or replacement of existing mechanical equipment Narrative of work to be done includln modification to duct work. Equipment specifications. Installation of Gas Fire ' lace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. $ 11 NOTE: Water heaters and vents are included In the Uniform Mechanical Code — please include any water. heaters or vents being installed or replaced. uo w 58 �O i it it 4* 4$ it Oa es MX" t 41 4. $Pt MI6 4i 114 tie 4. • . • • , 3 , • k **0***kkAAAAAAAAAAAAAAA****AAAAkkhAltA*AAAAA*** ItY OP tUKWILA WA 1 1/44 1 100' 0.1 TRIADMIT hAAAAAANAA#AAAAAAAAAAAAA A 4***AAAAwAlli n AA*AhA*-4AAAAAAAMAkkA*** 4 IRANONIT Number: P9000298 Amounts 83.75 0008r00 IS:29 Payeent Method* CHOCK Notation: JAMES R LE(.. tnit: WER Permit No: M2000-093 Typos 9.MOCH MECHANICAL PERMIT Parcel Nos 730060-0465 Site Addreeas 4030 13 140 OT Total Foe#s 03.75 i'h IPuyswrt 83.75 lote1 ALL Plates P3.75 Balances .00 A **********A0AkAAAAAA*AkAAAA*********AA*AAAAAA* ACCOUlit COOO Onni7rIption Amount. 000/345.830 PLAN CHECK - NONIMO 16.75 000/322.100 MECHANICAL - 1JONME0 67.00 4,13*4 06/09 9711 TOTAL August 16, 2001 Mr. James K. Lee 8200 So. 123rd PI. Seattle, WA 98178 Dear Mr. Lee: city of Tukwila Department of Community Development Steve Lancaster, Director RE: Permit Status M2000 -093 4030 So. 140th St. In reviewing our current permit tiles, it appears that your permit for installation of dryer vents and exhaust vent at Birchcrest Apartments issued on June 8, 2000, has not received a final inspection as of the date or this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date ague)) permit, or if the building or work authorized by such permit is suspended or abandoned at any time alter the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date adds letter, the Permit Center will close your flle and the work completed to date will be considered non- complying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206) 431.3670 if'you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, 4144 t Otrrdiii‘d Kathryn A. Stetson Permit Technician x c, :. 1zilo No ; t9?A9 Mx93 [Juane Qriftln. Ruildinu Official Steven M. Mullet, Mayor AWNS 6300 Southcenter Boulevard. Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206. 431 -3o6S a_ 1. •grtuw • .p .,.1 L4I rod# J //Ai1, t. G)'T Gt4IN.5 t REAM CGr'4r,t ()Lir no PR o vow x 1rLGttD I Al r a 4 C`Nr✓ is rtetivj that .0o 1 N-.1.: - 11.1 , • , a a._._ a . ..a,•■, It 9. 12 2.1 31.a . u.a., -=- 1 h... .. 91. 4 L. "Mar t. "00 LO? i t.• 17.41 "") 11 ?s/•s►` Ctt 'ni g[3t .,&. 3 aiw 7 A MD %IA 51D I STD EOM A%O 1'1.b Al* ".;(k1 .., , +> ,•• .......,..22....,21.. *.41/W..., 1 we»_,_...- .........••••• • ••• •••• — ,- - • , �t,►Lit,, G;. 1.199 . sa Work, 121212216 2 r,.,w...., ttsY.A.Mrr U.Ir_NJ/M/k! Wlr., • .00 2411 prvirs 74: ti' • ti 4 'i' K 4' 9 ,, :r s�/iHa `/�� d 1i144,; (l t } c ,,. . =11 1 1 „ ' 2. ) i ► ; G ` 43€9 ,�► • At, . s, y ..+rriNessZ.ift : , ,,,�, : 0541= *r 0 I/ 1112 I 3 1 �Z SSA 1� L % . LM'm tali i LAMA 1sa ' 1 4114W 1t+W OW& 11%4 4& Wro 64* a 64O ' 6 4 e 41 l� 1Z • T 1 "P 1..,f3,.....p.,1„1 we -, rr 91,1 r .111.111.1.1•1•••• s.'fl r a.� z 4 :71 Ill Ct7 1L c} a 0 CJ W CV —I $ I 1l , .sa.t k. aa1>w a . . z s s .2 • 4 1 : s 1 1 1 , :ar c . 4a 20.111. AA. ursa.a11Mass s . 9 MS . ale s 3,4CK WA ,BLawFl2» I `Vww'rr "`Zc 24. 2t.. 7A ig 1‘, i 1 An as mom a:, s . ass :a . s an. 2 (3w Mr.ii2. /4. 12. 10 s G ? Po5aD L IIu i%J z)' RO o M 402. S,I4a' ■KW►'LA i VaA Q% IC, s` J'/}PC.S k. L. (200 770_ - 16 RI- 4 - Z. 0 Ca 0 ■ d .+ C +'2 34CK ?A AP sec rom Isfeicy VN7'$ 1 5 " 0 10'o -.s . $Pfrc r, 4 - ,-ert fr 10414 WALL. (6Acs4 \ ALm Moog i 0.5, (I o,G') S tat. lit Wet Al. tic ... lbw __._sisamm. fl ere.. ANIMISM 111111! AK. saal.,salmos: tit a ..1.01._. M tit/ ��. - _* ,t... lr.r'e OINK , 411111B1 titer tier r :*n< ttNiestettat Doc 0 tel tittit Pvcr (') T/V $ LJ L ed) , N ii UPM (g) f aN (6) EL ) LkuNDAY koto- Tiz y Fk tuts (c), f cHA J Ceti. t2u () t K 4{)2 • i u St + LA- 104— ye UN 4 o; $.(4) ( TNSu L4r EP) 3E LOu) L OT .•..••■■•••=...."` '..""`s -pgi)rete:i) tAtoi,r)p# Ram,. 140 Sr C" tev.g a L (4,^ 6� ? 71 /6:4- f PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M2000 -093 DATE: 5-8-2000 PROJECT NAME: JAMES K LEE LAUNDRY ROOM SUITE # __ Response to Incomplete Letter # ....__Response to Correction Letter # __Revision # After Permit Is Issued SITE ADDRESS: 4030 S 140 ST �x. Original Plan Submittal DEPARTMENTS: R }siDivision Ci `1 U Public Works L. Complete Comments: TUES /THURS ROUTINGS Please Route REVIEWER'S INITIALS: Fir Prevention 11 0- - 4oc Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required APPROVAI.S or( CORRECTI,O,NS: (ten days) Approved ❑ Approved with Conditions REVIEWER'S INITIALS: Planning Division DATE: DATE: Permit Coordinator No further Review Required El DUE DATE : 5.9-2000 Not Applicable ❑ DUE DATE_ 6 - *2Q00 Not Approved (attach comments) ❑ comcj O N DON DUE DATE. Approved E Approved with Conditions:: Not Approved (attach comments) ❑ REVIEWER'S INITIALS; DATE: WRROUTE.DOC 5/99 STATE OF WASHINGTON COUNTY OF KING CITY OF ` - y'KWILA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION 1. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code Washington, a copy of which Is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor Is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. ..... , and will therefore not be performed by a registered contractor. I understand that i may be waiving certain rights that 1 might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. AFFCONT 1/13/00 ) ss. , states as follows: /1" APPLICANT Signed and sworn to before me this r d day of 20 ''c" . \--i -CI, - ( FVPL N JBLIC in and for the State of WasInIngton, residing at Name as commissioned: My commission expires:.___ H -4 County. 18.27.090 Exemptions. This chapter shall not apply to: 1. An authorized representative of the United States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of a structure; 6. Any construction, alteration, Improvement, or repair of personal property, except this chapter shall apply to all mobile /manufactured housing. A mobile /manufactured home may be Installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 7. Any construction, alteration, Improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them Into, or consuming them In the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for Tabor and materials and all other items Is less than $500, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division AFFCONT 1/13/00 of the operation is made into contracts of amounts less than $500 for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work Is performed by a registered contractor; 11. An owner who contracts for a project with a registered contractor; 12. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but this exemption shall not apply to any portion otherwise covered by this chapter who constructs an Improvement on his own property with the intention and for the purpose of selling the Improved property; 13. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work In or upon their own properties; 14. A licensed architect or civil or professional engineer acting solely In his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the elate of Washington while operating within the boundaries of such political subdivision. The exemption provided In this subsection is applicable only when the licensee is operating within the scope of his license; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; 16. Contractors on highway projects who have been prequalified as required by chapter 13 of the Laws of 1961, RCW 47.28.070 with the department of transportation to perform highway construction, reconstruction, or maintenance work.