Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M2000-185 - BOEING #7-34
M2000-185 Boeing #7-34 12779 Gateway Dr City of Tukwila Community Development / ,public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M2000-185 5 Type: 8 -METH Category: NRES Address: 12779 GATEWAY DR Location: Parcel #: 271600 -0060 Contractor License No: HERMAC*217NT TENANT BOEING #7 -34 12779 GATEWAY DR, TUKWILA, WA 98188 OWNER KAISER GATEWAY ASSOC 12870 INTERURBAN AVE 5, SEATTLE WA 981168 CONTACT DALE GARNER 1221 2 AV S, KENT, WA 98032 CONTRACTOR HERMANSON CORP. 1221 2ND AVENUE NORTH, KENT, WA 98022 * * * *•k * *-k * * * * * * * *k * * * * * * * * * k ** k ** k k k k* k * k * * k k *** k* ** * k * k *•k k k k * ** kit k Permit Description: INSTALL (2) NEW LINEAR DIFFUSERS & (2) NEW RETURN DIFFUSERS, DISCONNECT & CAP EXISTING EXHAUST IN 2 PLACES & RE- CONNECT IN 2 PLACES. SERVICE EXISTING LIEBERT UNIT & AIR BALANCE. UMC Edition: 1997 * * ** ' k ` * * * ** ***k * *** Permit Center Autt rized Signature MECHANICAL PERMIT Valuation: Total Permit Fee: kkkk *****k*kAkk ***kkkk+ ***kkkAAAkk J *k *kkk* Date -ao Status: ISSUED Hued: 08/30/2000 Expires: 02126/2001 Phone: (206) 431 -3670 Phone: 206 - 575.9700 Phone: 206 575 -9700 2,985.00 46.50 I hereby certify that I have read and examined this p and now the same to be true and correct. All provisions of 11.w and ordlnandes governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Dat - - � - ,0 Signature: Print Name : (1 ' `� �i, . ! ! '�; kt.tc = 4 . T 1 t 1 e : - _ 112A,t _'Y7 CAlat►•i..< t k* * **'k ** This permit shall become null and void if the work 'y not commenced within 180 days from the date of issuance, or if the work s suspended or abandoned for a period of 180 days from the last 1t. ,pect1on. CITY OF TUKWILA Permit No: M2000.18t Address! 12779 GATEWAY UFO Suite: Tenant: BOEING 117-34 Type: n --MECH Parcel #1 271600-0060 k• kit * * * * *A **** * * ** AA *•k *•k k•k*** *** * *•kk * *•kk k Permit Conditions: 1. Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identi- fication showing the fire performance rating thereof, 2. Electrical permits shall be obtained through the Washington State Division of :L ibor and ;Industries and all ?electrical work will be :inspected : by that agency (248-6630). No changes .Will be .nw de to the p 1 ans : # un l e: s' approved . by the Engineer and the 'Tukwila Building division. All per rits, e i nsptet i on records, and approved plans shall be avai lable: ; atw ° the ':job site prior to the start of any con» struc 'ion, Those documents are to be maintained and ava1 e►ble ;urit i final inspection ;approval is granted. All j t t iistruct ion to be done in conformance with 'approved p l ani-and requirements of the ;; Uniform B u i l d i n g Code 01997 Ed t tibn ? as• amended, _Uniform Mechanical Code (1997 F d i t+1 o►n ) an l ' ashington State Energy Cede (1997, Edition) . Va of Permit. 1he .issuance, of a: permit or approval o p1 nit, specifications, end computations shall not be con st`t tied to bo ,'a .permit fur, or an approval Of, any violation of, any of-the provisions of the b u i l d i n g code or of any other ordln+arnce of the jurisdiction. No permit presuming't g 9 V , e ' E author i ty to violate or cancel the provisions of t h i s codpsha l 1 be valid. Manufacturers installation instructions required on site for the building inspector review, Status: ISSUED Applied: 08/23/2000 Issued: 08/30/2000 - k*• k* Ak *A *•k * **kkk #*k * * **kA * *k ** Project Name/Tenant• . : * . • _ , 1111 - 11111. 11111. Value of Mechar Equipment: 1 Site Address : J_A _ . 11.. Cit State/Zip: Tax arcel Number: � - 4_ (Jo ,1 Property Owner;, .. ? Cit State/Zip: . , Phone: ( ) Street Address: City State/Zip: Fax #: ( ) Contractor�' fiarn,2S� eb �� City State/Zip: ' 4 Phone: o10(9 ) �_.ls% -. ` 100 Fax 11: ( ) C CYO 6 s - 9 800 Street Add e s: Contact Person: ,...J Phone: ( ) r Street Address: AA . City State/Zip: Fax #: ( ) . , ' U 'PING "O VNER'OR AU ORIZED AGEN r ' 1 ©ala, ,..126,17,0 , Signature: Print name: ,' Phone: ( 0a4 ) 5 '�S �6U Fax II: (2010 ) sir .9800 Address`,, a % r \ Cit State/Zip: . , CITY OF TC "WILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 F STAFF USE ONLY • r:.. :::::: - Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED' (TO RE FILLED OUT BY APPLICANT) Lion of work to be done (please be specific): --►. �.,.. ± Lb- 1 14 A b._ A Asa k • _A na, .iw.►.I. . � 1 lAkt. Ilk Descri Qr to N u. tu Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit If issued OR submit Form H-4, "Affidavit In Lieu of Contractor Registration*. � O Building Owner/Authorized Agents It the applicant is oilier then the owner, registered archltrcVanglnear, or contractor licensed by the of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of ibis submittal. I HEREBY CERTIFY TIIAT I HAVE READ AND EXAMINED THIS A(P'f iC ATION AND KNOW TILE SAME TO OE TRUE FINDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. U. tij� N Expiration of Plan Review • Applications for which no permit is issued within 100 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 100 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once, Date application accepted; W7/99 u,ech perrelt.duc Date application expires: 007 Application taken b • (initials) ANA z �w U© rt W ✓ (� y p i . Submittal Requirements Floor plan and system layout N Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Ar Details and elevations (for roof mounted equipment) and proposed screening ') Heat Loss Calculations or Washington State Energy Code Form #H -15 \¢ off H.V.A.C. over 2,000 OEM (approximately 5 ton and larger) must be provided with smoke detection shut- and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). N land Specifications must be provided to show that replacement equipment complies with the efficiency ratings other a • . licable re. uirements of the Washin:ton State Nonresidential Energy Code.. I VV '1 Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal RESIDENTIAL: Two complete sets of attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code - please include any water heaters or vents being installed or replaced. Submittal nequire►►►c'►►t.` Now to Family Ros� ldence ileat loss calculations with specifications o r Form ft6. ChanAe•out or re filament of oxlstin mechanical equipment Installation of Gas Fire lace Narrative with specification of equipment and chimney typo, If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition, 912109 ndscpnU.dac NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. t 44 ** # *F ## **** ** A ** * *A ***4 4 * * ***** *A* sF� *4 *4* TY OF tUKWZLA f : ylA , � ( -- ( TRANSMIT * * tit 40* #* *** ***A *** * * *A**4 * a4 * **4 * *;14 *: ** * *4** *a14* ** *A ****tl RONSOUl. Nui tier : 89800344 AmOurtt: 46.:0 08/30/O0 12i 4b Ptvt nt. Mr thod: CHCCR Notation: HI.0 }IANOON COMPrahf Init;s TLR w :r na s.:a»x +:s t r sx • 4s. of s.. ax O. s.s. w. 4+ 44 or r. s..+ 4. { "awn a. O. 14 axar awak 04 0, ar x a. wrs «, ♦xs•I as sr sx Permit Not M2000-185 Types H •MI.CH MI "CHANICAL PERMIT I'itreel Nov 271600 -0060 MddPoataa 1277: GAlaf3Nfa7 OR Total foal: 46.50 This Puymant 46.50 T o t a l ALL. Pt,t±t s 46.50 Oalancot .00 0* ** 4044 ** **,414 A40,44 * * * +* *444 4o*A 11.44ko491o4 **A*4,A44 404#4,11**A AccoonL Cody 004/345.830 30 040/322.100 Dkaor I p (i on Amaort t PLAN CHECK NtihiRCV 9.30 MECHANICAL NONRE9 37.20 .s .L...x 04 1 I$4sx$4{..a04a0 it 44 aM.•.r 44 N .t t- *4txsxax ;!i+ a' s11. a' ate'.rt1 it 00 1a 04 00 .. I axt -.x ar at x<anr . M+.t i, f+ PERMIT NO.: ~r t is 5 MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 00002 Pre- construction © 00050 WSEC Residential ❑ 00060 WA Ventilation/Indoor AQC ❑ 00610 Chimney Installation/All Types ❑ 00700 Framing ❑ 01080 Woodstove ❑ � 01090 Smoke Detector Shut Off 01100 Rough -in Mechanical 01101 Mechanical Equipment/Controls 01102 Mechanical Pip/Duet Insul 01105 Underground Mesh Rough -in 01115 Motor Inspection 1400 Fire Final 01800 Final Mechanical 04015 Special -Smoke Control System CONDITIONS 0001 No changes to plans unless approved by Bldg Div ❑ 0014 Readily accessible access to roof mounted equipment 0016 Exposed insulation backing material 0019 All construction to be done In conformance w /approved plans ❑ 0002 Plumbing permits shall be obtained through King Co 0027 Validity of Permit 0003 Electrical permits obtained through L & 1 0036 Manufacturers Installation instructions required on site "BTU maximum allowed per 1997 WA State Energy Code" 0041 Ventilation Is required for all now rooms & spaces "Fuel burning appliances "Appliances, which generate,,.," "Water heater shall be anchored,,,," e Additional C9ndltions: II NM TENANT NAME: FEES Basic Fee (YIN) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace/Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Fioor- mounted Heater (qty) Appliance Vent (qty) Heating/Rettig/Cooling Uni! /Sys *cm (qty) Boiler /Compressor to 3 HP/100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP/1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 cfm (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter SS) Add'I Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) . Miscellaneous Inspections (hrs) Add'l Plan Review (hrs) Plan Reviewer: Permit Tech: Date: Date: 6 Zie Project (..... Type of Inspectio. • Add > s: Date called: Special instructions: Date want • . , w Requester: Phone: Inspector: $47.00 REINSPECTION FE f"QUIRED, Prior to inspection, fee must be paid at 6300 Southcenter Blvd. Suite 100. Call to schedule reins ection. Receipt No: Date: Date: INSPEC1ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: INSPECTION RECORD Retain a copy with p /rmit PERMIT NO. (206)431.3670 Corrections required prior to approval. PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: Mi2000 -185 DATE: 8 -23- 2000 PROJECT NAME: BOEING BUILDING #7 -34 SITE ADDRESS: 12779 GATEWAY DR _ Original Plan Submittal _Response to Correction Letter # __. ...... DEPARTMENTS: B�iildirig Divisi n Fire Prevention J1 Structural l�w ❑ Public Works DETERM 71 OF COMPLETENESS: (Toes,, Thurs.) Complete Comments: APPROVALS O_R GQRRECTIONS: ((en days) Approved ,,,,,,,„ Approved with Conditions REVIEWER'S INITIALS: Incompkdte CORRECTION DE N h: Approved Ej Approved with Conditions I REVIEWER'S INITIALS: Response to incomplete Letter ,,,,Revision # _. . Before Permit Is Issued ..1 Planning Division Permit Coordinator DUE DATE: 8-24-2000 Not Applicable ❑ TUES /THURS ROUTI G: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: f DUE DATE 9_21 -2Q0_ Not Approved (attach comments) DATE: DUE DATE Not Approved (attach comments) DATE: 111111111111111 LICENSE DETAIL INFORM TION Form Page 1 of I STATE OF WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES Specialty Compliance Services Division P. O. Box 44000 Olympia, WA 98504 -4000 THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS: LICENSE DETAIL INFORMATION Current Filter: None Registration# or License HERMACL0058J Name HERMANSON COMPANY LLP Address 1221 2ND AVE N Address City KENT State WA Zip 980322945 Phone Number 2085759700 Effective Date 1/11/00 Expiration Date 8/21/01 Registration Status ACTIVE Typo CONSTRUCTION CONTRACTOR Entity LIMITED LIABILITY COMPANY Specialty Code GENERAL Other Specialties UBI Number 802004844 * *VIEW PRINCCIPAL OWNER(8)_,FQR_ THIS ,_L10E.NSE* * • *VIEW_CO[1TRAGTORBQNQ. /SAVING SJNFO131 A_TIQN * * * * *G_FIKKANQUIRY FOR SUMMONS AND COMPLAINTS* * * * * * yiew cONTRACTo IN UBANg ..INF_ORMATLQ * * * New inquiry by CITY, NAME, PRINCIPAL OWNER NAME, NUMBER, UBI NUMBER or return to the L &I Construction Compliance Home Page http:// www. lni, wa. gov/ CONTRACTORS/TF2Form.asp?License = HERMACL005BJ 8/30/00 ig atarirgioa aijimniesti in artist II aption SIM - NVI.1111V310 WTI SI 3111V11:1 SIM NI 111311(1300 3111. acuom } ,>( Other Micro Corn Systems Washington Ltd. ATTENTION The next image may be a duplicate of the previous image. . www.microcomsys.com 12608.8 INTERURBAN AVENUE SOUTH TUKWILA, WA 98168 TEL (206) 248.3191 FAX (206) 2483313 EQUIPMENT NAME RM. NO. CFM CHRONOFLEX PROCESSOR 103 300 60" FILM & PAPER PROCESS 104 100 HOPE 146 PROCESSOR 176 100 I. CROVEX WASH— OFF PROCESSOR 172 350 i CROVEX WASH— OFF PROCESSOR 174 350 PAKOLITH 147 75 AGFA COLOR PRINT PROCESS 138 500 HOPE COLOR PROCESSOR• 138 100 KODAK PRINTER 133 60 KODAK PRINTER 135 60 KODAK PRINTER 137 60 KODAK PRINTER 134 60 B & W PAPER PROCESS 149 100 B &W PRINTING 151 100 CHEM. COLL. PIT 118 3000 FILM z _PRQrf5SOR — 110 950 HOPE RA4 PRINTER 114 100 NEGATIVE ANALYZER 114 60 PROCESSOR 110 100 EMPTY 112 0 LAB AREA 114 1100 OFFICE 115 150 CHEMICAL MIXING RM. 119 400 CHEMICAL STORAGE 120 400 PROCESSOR 112 950 P120CETSOR 182 500 240 CFM 3 825 CFM 40 �4II �I II 22/14 630 CFM 1000 CFM I 2M10 480° CFM AC 12/10 50 100 CFM AG 440 CFM 250 CFM 100 CFM 60 CFM 60 CFM 60 _ 340 CFM 5/16 15/16 UP 1 1 130/16 18/18 UP TO 2/12 U 0 850 CFM 2M10 M501 240 CFM 3 20 CFM 16/16 18/18 580 CFM RAG \ 580 CFM 580 CFM 450 CF 1125 CF 8 2M10 M502 ATA VAV 950 CFM 560 CFM 375 CFM ® 300 CF 50 100 M 18/18 160 140 30 rw. CFM 100 CFM 400 CFM 60 AG CFM 0 M II ii 30_CE 210 CFM 145 CFM 85 CFM 14/12 770 CFM 2M10 M501 11111111111111 410 CFM J� 100 t 1ta_ 1160 CFM 380 CFM 22/8 780 CFM 40 1950 C 26/12 320 CFM 950 CFM X502 400 CFM M10 M50 CPU L 2M10 M503 2M10 B C D REVISION RECORD DRAWING 7 -34 PHOTO PROCESSOR J# 92053 NEW DATA CLOSET (11101475) INTERIOR MODIFICATIONS (1L02092) VENTILATION IMPROVEMENTS Jif NO3236 RY JCR OC BM MMM MM DLD APPROVED KSM PJV DATE 3 -25 -92 09.17.92 02.16.95 05.30.97 11.08.99 su REVISION PHOTO EQUIP. RELOCATION #P01892 WH AW MB Li CA NM or DLD APPROVED FRB DATE 08.03.00 ® ®E71w1 FACILITIES DEPARTMENT ❑ AUBURN, WA. ❑ BELLEVUE, WA. ❑ EVERETI, WA. ❑ KENT, WA. n PORT1 AND, OR 1.1 MINION, WA. E SEAIIL[:, WA. 98002 98007 98201 98031 97220 98055 98121 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN BY D.MCCLUNG CHECKED P.MAAS ENGR CHECKED K. RAM SEY I( , RAM SLY 11 DATE L15.87 18/18 UP TO 3000 CFM A 24 "o24" FILTER GRILLE SUDRRE 300 CFM PA4SE 3 ISSU FOR CONSTRUCTION /1AD&4 Data: a -s -oA MECIIANICAI_ MASHY AUc 2 8 TWO _FfEJEiU/ ?c, Dy1TE � EXHAUST FAN EF -3 GENERAL NOTES: 1. FOR TYPICAL ROOF MOUNTED EXHAUST FAN INSTALLATION, SEE DETAIL 4 2M101 M501 CONSTRUCTION NOTES: JOB NO. P01892: : - REMOVE EXISTING RETURN GRILLE AND PAINT EXPOSED PORTIONS WHITE TO MATCH OTHER GRILLES IN BUILDING *. INSTALL GRILLE IN NEW CEILING GRID IN APPROXIMATE POSFHON INDICATED. CONNECT TO EXISTING RETURN DUCTWORK. BALANCE AIRFLOW TO INDICATED VALUE. * ALTERNATELY, REPLACE WITH NEW MATCHING WHITE GRILLE. EXCSTLIO GRILLE TO REMAIN IN PLACE AS —IS. BALANCE AIRFLOW TO INDICATED VALUE. > BALANCE AIRFLOW AT EXISTING GRILLE TO VALUE INDICATED, OR TO SAME CFM AS SUPPLY AIRFLOW DETERMINED ON DWG 1M10 FOR THIS ROOM. CONNECT EXISTING 4 "0 EXHAUST DROP TO HOPE RA4 PRINTER USING HOSE RELOCATED WITH PRINTER. 5 DISCONNECT AND REMOVE EXHAUST GRILLE. MOWi E' EXISTING DUCT TO CONNECT TO 3 "0 EXHAUST PORT ON NEGATIVE ANALYZER RELOCATED FROM ROOM 137. REBALANCE EXHAUST FAN EF -13 TO PROVIDE INDICATED CFM AT EACH OF TEN CONNECTION POINTS. EXHAUST FAN EF -9 EXHAUST FAN EF -12 EXHAUST FAN EF -14 EXHAUST FAN EF -15 CITY OF TUKWILA APPROVED .0 . 7A KEY PLAN HVAC RETURN AND EXHAUST AIR DUCTWORK PLAN SOUTH 7 -34 BUILDING COL A -E /1 -8 PLAN NORTH GATEWAY H6 BE &C ENGINEERS UST REVISION - 2M10 JOB NO. 102092 URU IID. F SYRDOL 7- 34 -2M10 08.03 .00 DATE 92019 \719M0102 DID /08,01,00/1826 �fI 60 CFM 40 60 C 120 60 40 CFM 170 CFM 165 CFM 120 CFM 350 CFM 165 CF 1- 1 0 8 RAG 350 CFM 350 CFM 520 CF 95 CF 50 C 200 CFM /RAG 120 CFM 280 CFM 64/14 • PROVIDE FIRE DAMPER RECORD DRAWING A 7 -34 LIQUID LN2 F 1a1SC tQU1PT RE4d0VAL #NO2628 PHOTO EQUIP, RELOCATION #P01892 FOR CONTINUATION SEE SHEET 2M10 DWM QC BM DID 22/12 KSM WH DM PJV 165 CFM 3 -25 -9 11.16.92 09. 17.99 08.03.00 55 CFM 270 CFM APPROVED FLOOR PLAIN SCALE: 1/8 " =1' -0" 120 CFM 240 CFM (TYP 2) 50 CFM 350 CFM 200 CFM (2TYP) 18/18 UP TO 64/26 /RAG \460 CFM 2450 CFM 64/40 SUPPLY '." -- (REF) ROUTE UNDE SUPPLY DUCT 100 200 CFM ROOF TO 350 CFM 250 CFM (2 TY' 220 CFM 150 CFM 500 CFM SEE DETAIL 2M11 M501 FOR CONTINUATION SEE SHEET M -502 600 CFM (3 TYP) 1540 CFM 70 CFM (2 TYP 1800 CFM 300 CFM (2 TYP) PIA "Sal vj El RELIEF (4 (YP) KEY PLAN AG 1260 FM 5 FttTG )360 CFM a G 390 CFI .(TYP 3) REVISION .BODE ®NG FACILITIES DEPARTMENT ❑ AUBURN, WA. 98002 ❑ BELLEVUE, WA. 98007 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 SEATTLE, WA. 98124 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEP DRAWN DY U.MCCLUNG CHECKED P.MAAS ENGR. DAT CHECKED K.RAMSLY APPROVED K.RAMSEY APPR VED D. CMULLEN EF -16 300 CFM W /FIRE DAMPER DATE 7.15.87 10x4 300 CFM SOME 24/12 RELIEF HOOD EXHAUST UP TO EF -10 (24 HOUR OPERATION) SEE DETAIL 1 M50- CONSTRUCTION NOTES: CAP EXISTING 5 "0 EXHAUST DUCT (FROM RELOCATED HOPE RA4 PRINTER) AT FIRST ELBOW ABOVE CEILING. RELOCATE AND REUSE FLEX HOSE WITH MACHINE IN NEW LOCATION IN ROOM 114 — REF. DWG 2M10. CAP EXISTING 4 "0 EXHAUST DUCT (FROM RELOCATED NEGATIVE ANALYZER) AT FIRST ELBOW ABOVE CEILING. RELOCATE AND REUSE FLEX HOSE WITH MACHINE IN NEW LOCATION IN ROOM 114 — REF. DWG 2M10. 2M1 GENERAL NOTES: • EXHAUST GRILLE— KRUEGER SERIES 20L 10x4 16 Ga. CONSTRUCTION W/ SINGLE DEFLECTION. • HOODED WALL CAP— GREENHECK MODEL WCSP, STEEL CONSTRUCTION W/ BLACK ENAMEL FINISH, BUILT —IN BIRD SCREEN AND DAMPER. LEGEND: PffASV 3 ISSUE FOR CONSTRUCTION Date: s -e o0 HVAC R TURN AND EXHAUST AIR DUCTWORK PLAN NORTH 7 - 34 BUILDING MECHANICAL MASTER COL A— E/8 -18 GATEWAY #6 • -.M.._ PLAN NORTH BE &C ENGINEERS LIST REVISION SHEET 2M1 1 JOB N0. 87060 DWG NO. 7- 34 -2M11 CITY OF TUTA APPROVE) AUG 2 3 iGu' flECEIVEC CIN OF TUK"VI AUG 2 3 2781 PERMIT CENTER C SYMBOL 08.03 .00 DATE OF