HomeMy WebLinkAboutPermit M2000-221 - SOUTHCENTER MALL - THE PICTURE PEOPLEf • M2000-221 Picture People 688 Southcenter Mall City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M2000 -221 Type: B -MECH Category: NRES Address: 688 SOUTHCENTER MALL Location: Parcel #: Contractor License No: AIRSYE *229KN TENANT OWNER CONTACT CONTRACTOR MECHANICAL PERMIT THE PICTURE PEOPLE 688 SOUTHCENTER MALL, TUKWILA WA 98188 RICHARD JACOBS GROUP 25425 CENTER RIDGE RD, CLEVELAND OH 44145 LYN WOUC ENBERG 75 60th ST SW, WYOMING MI 49548 AIR SYSTEMS ENGINEERING 909 SOUTH 28TH STREET, TACOMA, WA 98409 k * * * * *** * * * * * * * *** k * *4** A k kA* A k* k 4 ** k*** 4* * ***** 4 *444 *4 4 4 44 44 k ** *•k *•A * Permit Description: INSTALL (1) 6.25 TON RTU & (1) CFM EXHAUST FAN UMC Edition: 1997 Valuation: Total Permit Fee: Signature Print Name: (206) 431 -3670 Status: ISSUED Issued: 10/12/2000 Expires: 04/10/2001 Phone: Phone: 800 -285 -7866 Phone: 206 628 -9484 23 ,000.00 51.75 •k** * * *4* ** kA* A k A4 A A4• k•4.4 k k 44 4*• k kA ** A•A 4 k 4A 4 4.4 4 A-4 4 4 4 4 4 # -k 4 4 4.4 4 *•4** 4 - 4 k A 4* 4 4 4 Permi Center T harizedSignature bate r hereby certify that I have read and examined this permit and know the same to. be true and correct. A i 1 ' prov i s i on. of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of t h i s permit does not presume to g i v e authority to v i o l a t e or cancel the provisions of any other state or local laws regulating construction or the performance .t work. I am authorized to sign for and obtain this building ..�_- Title: u�r This permit shall become null and void if the work is not commenced within ISO days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 4 { Address: 688 SOUTHCENTER MALL Suite: • Tenant: THE PICTURE PEOPLE Type: 8-MECH Parcel #: AAAA**A**********AAAAAMAA*4*******AAAAAAk***********AkAA0c************* A* Permit Conditions: • 1 Electrical permits shall be obtained through the Washington • State Division of Labor and industries and all electrical work will be inspected by that agency (248-663()) 2. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building 'Division, • All permits, inspection records, and approved plans shall be "available at the job site prior to the start of any con- struction'. These-dOcuments are to be maintained and avail- Able untfT'final inSpecCion approval is' granted, 4, All construceion' e0 be done In conformance with approved plansand requirements of the Uniform Building Code (199' Edition) as amended, Uniform Mechanical Code (1997 Edition), and ,Waihington State Energy Code (19)7 Edition). b. Validtty,of,Permit. The issuance of a permit or approval - 0, plan*, Specifications, and computations shall not be con- strued to be a permit for or en approval of, any violation' of4ny of the provisions of the building code or of any other ordinance of the jurisdiction. No permit eresumingto give 'authority to violate or cancel the provisions of this cede, shall be valid. Manufacturers installation instructions required on site for* the building inspectors review. 1 herebypertify that I have read these conditions and will comply with the* as outlined. All provisions of law and ordinances goVerning this work, v011 be complied with, whether specified herein or not.' The granting of this permit does not ,presume to give authority Co violate or cancel the provisions of any other work or local laws reguiating con'weetIon or the performance of work. Sipn ture: Print Name: 4V4,441.. CITY OF TUKWILA • OW M 4,41 Permit No: M2000-221 Status: Applied: Issued: ISSUED 09/14/2000 10/12/2000 Date; • A Project jV f' � Teo l � .}' _ 1 � / Value of Mechanical Equipment: 3 Ad ress : IP 1.01 e ) h G I / ,, �f • i ' i � /I/l -, a City State/Zi.: . - ' : b . Parcel Number Tax Parcel umber• ,202 ( �Qo V Prfi Otyner: /I I "W I :a ca Gvo p Ckeot/o d ©1-H City VIV � Phone: ( ) yyo 608. 7O Fax 02 80e1 &7o, Phone: ( B, ) 0?03. 5 7a. fyg 9 Street Address: G en*i 4 e_ d Coni actor: Street Address• 10 5 a � 8 • 7; Cot�a �) City State/Zip: g O 7 . Fax #: ( ) Contact Person: A 00 , e_fl -e./ / Phone: e3t20 6:24 'Mb& Street oddne a t e a Cit Sta 'Zip: Fax # s ( ) BUILDING O , NER 0 AUTHORIZED AGENT, Signature i . , ,' Date: Fax N , (� c , C.� f" g Print namaG (OQu _ / Phone: h ', 90 � a d I 1 1.30)1,1411A)< / b/. Mechanical Permit Application MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT Description of work to be done (please be s ecific): D pplic tlo ccepted: 11/2/99 notch pe nitdoc CITY OF T''KWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. e r R STAFF USE ONLY Project Number: Permit Number: Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H.4, "Affidavit In Lieu of Contractor Registration ". o$.. Building Owner /Authorized Agents If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BC TRUE UNDER PENALTY OF PER JURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review • Applications for which no permit is issued within 1 00 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition), No application shall be extended more than once. Dale a licatlon exp es: •' ow 0 r Applicatjon taken binitials) Floor plan and system layout Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 RESIDENTIAL: Two complete sets of attachments required with application submittal Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal Submittal Requirements Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Submittal Rl'ftlllrl'llll F1I S New Single Family Residence Heat loss calculations or Form 146. Equipment specifications. Chan e•out or_rsplacement of existing mechanical equipment Narrative of work to be done includin modification to duct work. Installation of Gas Fl�lace Narrative with specification of equipment and chimney typo. If using existing chimney, provide a letter by a certified chimney swoop stating that the chimney is in safe condition. NOTE: Water heaters and vents are included In the Uniform Mechanical Code — please Include any water heaters or vents being installed or replaced. w w O 0 O 0 (oW N W 15 0 co 8 z 0 u. � Z� ' 4,4 3 4 0 4 3 3 3 , 0 A**4.0h4A4A4 40:A**thAkA414A*4*A4A*A* trty OF TUKWILA. W ***41444A*14**A*A#41*4AA***Alla**• *44 ifeof**A*4kh44*.A*44.1.41,/, A YFANSMIT TRANSMIT Number: P9000374 Amount: ..71.; JO/L2/00 1209 Payment Method: CHCCK Notation: AIR SYSTEMS EHOI nit: ILO a 4% .0 S. 114 NW No 0, 4 • 4. o a. as •I 44 0* •0 I. 4, 4 Ai. Is S. I: • • 0.4 •• *8 ••■ • +. 4. 45 II OW 4.01. •1 . I. AV S. Permit 140$ M200A-221 Typo: 0-MliCH MECHANICAL PERMIT Site Address: rCO SOUTHCENTLII hALL Total F004$ 31.73 This Payment $1,75 Total ALL Pmts: Raldoce: .00 4#*44****oo ecount Code Deinription 000/20.930 PLAN CHETK S. NONRES 000/32:4.100 MECHANICAL MONRES Pi.wti0PO4woowworowd, sr wo 4 55 4* 45 S Amount 10.3D 41.40 003 10/17 /710 TOTAL 4,75 3'. "3 10 *fa' 4 Aoe.c4 PERMIT NO.: NI Z — zz 1 MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 00002 Pre - construction ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation/indoor AQC ❑ 00610 Chimney Installation /All Types ❑ 00700 Framing ❑ 01080 Woodstove 01090. Smoke Detector Shut Off 01100 Rough -in Mechanical 01101 Mechanical Equipment/Controls 01102 Mechanical Pip/Duct Insul 01105 Underground Mach Rough -in 01115 Motor Inspection 1400 Fire Final 01800 Final Mechanical ❑ 04015 Special -Smoke Control System CONDITIONS 0001 No changes to plans unless approved by Bldg Div 0 0014 Readily accessible access to roof mounted equipment 0016 Exposed insulation backing material 0019 All construction to be done In conformance w /approved plans 0002 Plumbing permits shall be obtained through King Co 0027 Validity of Permit 0003 Electrical permits obtained through L & I 0036 Manufacturers installation instructions required on site "BTU maximum allowed per 1997 WA State Energy Code" 0041 Ventilation is required for all new rooms & spaces "Fuel burning appliances "Appliances, which gpnerato...." "Water heater shall bo anchored..,." e Additional Conditions; FEES Basic Fee (YIN) Supplemental Fee (YiN) Plan Check Fee (YiN) Furnace/Burner • to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/WaIVFloor- mounted Heater (qty) Appliance Vent (qty) 1- teating/Refrig/Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 FIP /1,000,000 BTU (qty) to 50 HP/1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfm (qty) over 10,000 c1Yn (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator — Comm /ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter SS) Add'l Fees = Work w/o Permit (Y/N) Imp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'I Plan Review (hrs) Plan Reviewer: Permit Tech: Date: t (i/ Date: qzo . . INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 ate led: Date wa e : Special instructions: on, irn nspect Receipt No: INSPECTION RECORLr Retain a copy with permit ® $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reins ection. Date; r. PERMIT NO. (W6)431-3670 )431 -3670 Corrections required prior to approval. Date; Approved per applicable codes. COMMENTS: g a Project NIsme Address Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature FINALAPP.FRM City of Tukwila Fire Department TUXWILA FIRE DEPARTMENT FINAL APPROVAL FORM Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Rev, 2/19/98 Permit No. Steven M. Mullet, Mayor Thomas P. Keefe, Fire Chief T.F,D, Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206.575.4404 • Fax: 206.575.4439 Project: Type of Inspection: Address: A MR ... • : ate called: ` ! Special instructions: Date wanted: %, ,.. — 11,‘ Rta nester: ,PJjone: 2. PERMIT NO. $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule ruinspection. Receipt No: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 - 367 Approved per applicable codes. COMMENTS: Corrections required prior to approval. T pe of Inspection: Special instructions: Date wanted: © • Approved per applicable codes. (J Corrections required prior to approval, INSPECTION RECOIii Retain a copy with permit INSPECTION NO, PERMIT NO. CITY OF TUKWILA fUILDING DIVISION 6300 Southcenter 8lvd,1100, Tukwila, WA 9818 (206)431.3670 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd, Suite 100. Call to schedule reins ' ectlon. Receipt No: The Picture People Tenant Space F -672 Southcenter Mali Seattle, Washington Structural Calculations Rooftop Mechanical Unit I September 12, 2000 Prepared By: Andersen Bjornstad Kane Jacobs, Inc 800 Fifth Avenue, Suite 3800 Seattle, Washington 98104-3103 MZOcO • RECEIVED CITY OF TUKWIIA SEP 1 4 2000 PERMIT CENTER Southcenter Mail Tukwila, WA The Picture People Tenant Space F -672 Tasks; September 10, 2000 1. Review existing roof framing to support rooftop mechanical unit. 2. Review seismic loads that the mechanical unit needs to be anchored for. Machanlcai_Unit Information; Unit Type: RTU -1 Operating Weight: 850 pounds Roof Location: On existing equipment pad located between grids R & S and 21 & 22, Existing Equipment Pad: Approximately 24' by 24', 6" thick Lightweight concrete. Use 116 pcf for concrete density. Existing Roof Framing: 16H5 Open Web Steel Joist at 36" on center spanning 24' supported by W16x38's spanning 24'. The calculations (6 pages) verify that the existing roof framing is adequate to support the new mechanical unit. They also provide the anchorage design Toads for the mechanical unit for seismic loads. S TU SEP 1 4 2000 PERMIT CENTER ANDERSEN BJORNSTAD KAitic JACOSS • INC. CONSUL - Mid ENOINEECIS SEAttLE. WASHINGtON PROJECT; / Lr -411,6-1 G' -D (,( / � SUBJECT :. S OV.I_ .0 Pf ec , Lod C .1 1 tOt_ -r ‘Ck) A.4 DL47- ils 5 I I 1- 0 .*1- sot th ,S G(4 t4Lt,. ) Zf 1(7 UJTL 33LI t T.. z37Per /31,0 LA., 3 ? 2 S teU7LL =— 5 O JOB # BY: CP I \04,±- DATE _!/R OMO SHEET p ( / i fiw of STJ CITY RECEIVED F TUKWILA S E P 1 4 2000 PERMIT CENTER CONSULTING CNGINEERS SEA7?LE, WASHINGTON , I ANDERSEN BJORNSTAD KAN,: JACOBS • INC. 1 y 3/03 Atm a.k,( t2Lio 0/ k — '0 6-4-1— IA-t.GL. t Vt-e)3 l 3 3 zp,(1 tA) ez,q,(24u,7 6- 3571ti. Ai VlJ r►�t, 3 ,t.� 3 3 L/ "' , (j t ' CITY OF TU SEP 1 4 2000 PERMIT CENTER L. " t t6t tttrt tr I 81* 3,083 k V1114 4 left 3.083 k 24,00 ft MIIIAX 24.09 k.fs it 11.99 ft from tell tImax .0.8380 itt it! 11.02 ft from left Mr E 3400 k VittAx J 11 et 3,859 k RECEIVED CITY OP TUIGIVILA SEP 1 4 2000 PERMIT CENTER WO 3 ANDERSEN BJORNSTAD KAI JACOBS • INC. CONSULTING ENGINEERS SEATTLE, WASHINGTON PROJECT : SUBJECT: , ,_ pi( v6 A-0 S 4 c 41A„ c-a v , � - 1D Lac. x',wp (SDI �` j/1e jo I .= 1 -1(0 , 312 0x. 1-v 1, Y C LOp / /ham r. 7 /' D ? ki (WL V / S `tJJ) 3 (37.5 4 S S l,� L4 £O JI C�G. (1 L pc?) p 066 Ito JOB # DATE / 1./01) AlUt BY: �. SHEET u . 5 41t# e4 Li �.,. Y"Ze ,} 5 W 7- a Lv G O ' 1 / o 4-1.7 it+ .7- te5 1 / dull w- S`O RECEIVED CIYY OF TUKWILA SEP 1 't 2000 PERMIT CENTER 4 * . ANDERSEN B)ORNSTAD KAI JACOBS • INC, CONSULTINd eNGINEE SEATTLE0 WASHINGTON VMay = 217' r # \ ► on- S t.,, A. (I 1 1 1"1 � av` it4 isog. = _z1 -- reth,) 6 - ,- z e) iw o 3Z 6 RECENED CITY OF TUKWILA SEP 1 4 2000 PERMIT CENTER ACTIVITY NUMBER: M2000 -221 DATE: 911412000 PROJECT NAME: THE PICTURE PEOPLE SITE ADDRESS: AO SOUTHCEN�'ER MAIL XX Original Plan Submittal .,,....._Response to Incomplete Letter # Response to Correction Letter # Revision # _... After Permit Is Issued DEPARTMENTS: Buildivision • Awv a j4 Public Works ❑ DETERMINATION OF COMPLETE : (Tues., Thurs.) Incomplete ❑ Complete Comments: \PRROUTE.DOC 5/99 TUES/THURS ROUTTNG: Please Route REVIEWER'S INITIALS: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORD T IONS: (ten days) Approved ❑ Approved with Conditions REVIEWER'S INITIALS: Fir4 PCv4 -I4n Structural Structural Review Required CORR ECTION E E TION: Approved E Approved with Conditions ri REVIEWER'S INITIALS: Planning Division Permit Coordinator ■ DUE DATE:�� 19 -2000 Not Applicable ❑ No further Review Required DATE: DUE DATE: , , U- ' 1722QOO Not Approved (attach comments) El DATE: DUE DATE Not Approved (attach comments) ❑I DATE; City of Tukwila Fire Department Fire Department Review Control #M2000 -221 (512) September 19, 2000 Re: The Picture People - 688 Southcenter Mall Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at greater than 2,000 cfm require auto- shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) H.V.A.C. systems supplying air in excess of 2 000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the ower source of the air - moving equipment upon detection of smoke in the main supply-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1-5.2.8.2)) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been Steven M. Mullet, Mayor Thomas I? Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206. 5754404 • Fax: 206.575.4439 r City of Tukwila Steven M. Mullet, Mayor Fire Department Thomas R Keefe, Fire Chief Page number 2 obtained. (City Ordinance #1900) (UFC 1001.3) Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1900) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 2. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 3. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc; TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206.575.4404 • Fax: 206. 575.4439 r6.134124100 01/91 M r • • MY COMMISSION EXPIRES: DEPAR'TIVIENT OF LABOR REGISTERED. S PROVIDED BY LAW AS CONST CONT GENERAL DATE CC01'? :AIRSYE *229KN 02/01/2001 EFFECTIVE`: DATE :;.:: `; :" ".;05/1.5/1978 AIR SYSTEMS ENGINEERING INC 909 S 28TH ST TACOMA WA 98409 -8197 TIIIS CERTIFIES THIS IS A COPY OF THE ORIGINAL. DATE: SUBSCRIBED AND SWORN BEFORE ME THIS 1g NOTARY PUBLIC: X -e C ec•( . /://zie- , L(A 30 0 So 1.600 fusI7S • CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS REQUIRED FOR A COMPLETE INSTALLATION IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE PREMISES PRIOR TO COMMENCEMENT OF CONSTRUCTION TO VERIFY EXISTING CONDITIONS AND NOTIFY DESIGNER OF ANY NECESSARY ADJUSTMENTS TO THE CONSTRUCTION DOCUMENTS. 3. CONTRACTOR SHALL PROVIDE A GUARANTEE FROM DEFECTS FOR ALL MATERIALS AND WORKMANSHIP FURNISHED ON PROJECT FOR ONE YEAR FROM DATE OF ACCEPTANCE. 4. CONTRACTOR SHALL PROVIDE AND PAY ALL FEES AND PERMITS. 5. DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW APPROXIMATE LOCATIONS. CONTRACTOR SHALL INSTALL ALL WORK WITHOUT CONFLICT WITH OTHER TRADES AND MAKE ALTERATIONS AS REQUIRED WITH NO ADDITIONAL COST TO OWNER. 6. ALL LOW PRESSURE DUCTWORK SHALL BE GALVANIZED SHEET METAL. DUCTWORK SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA MANUAL. ALL DIMENSIONS ARE NET INSIDE CLEAR. 7. ALL LOW PRESSURE DUCTWORK SHALL BE SEALED PER SMACNA SEAL CLASS "B" AND BE EXTERNALLY INSULATED WITH A BLANKET WRAP 2" THICK, FOIL FACED, STAPLED AND TAPED AT ALL SEAMS IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND REQUIREMENTS. 8. FLEXIBLE DUCT SHALL BE OMNI -AIR TYPE 1000 OR EQUAL FOR 0" TO 2" PRESSURE AND A MAX. OF 3' LONG. 9. PROVIDE MANUAL OPPOSED BLADE DAMPERS W /LOCKING QUADRANT WHERE INDICATED AND NECESSARY TO BALANCE AIR SYSTEM. 10. CONTRACTOR TO HIRE INDEPENDENT AABC OR NEBB CERTIFIED TEST AND BALANCING FIRM WITH AT LEAST (2) YEARS EXPERIENCE TO ADJUST AIR VOLUME TO WITHIN 5% OF CFM SHOWN ON PLANS. SUBMIT COMPLETED BALANCE REPORT TO LANDLORD REPRESENTATIVE FOR REVIEW /APPROVAL SEP 2 1 2000 etmorKG DIVISION 33 IIUSIC SQ. W., 106A NASHVILLE, TENNESSEE 31203 615221.1209 FAX 615228.1215 EXPIRES 6/21/ Revisions i HVAC SPECIFICATIONS EF -1 125 CFM /// //Y// /y/ Oir ./////// :0777, / / /ir Pi/ " r //J / ///Viii/re,62 = %/lireAlO/// ///.0" 1�1 RM2 200 RG 250 16x12 PROP 1 °C ^511 RACK PROD RACK 12x12 MGR AREA L r �►j AIL 0 4_ -DR 11 RG 500 CD 250 PCA13 j CD RG' 225 450 RG 450 14x14 Lu lll 77 r► L -18x12 ED 250 / CD 250 18x14 �R1U -1 2,500 CFM 24x14 ARV 18x14 ; T5L_ 12 "0 � P.ZZY F4tEL RG 475 CD 250 C C r ; TSL � =R ER 12x12 tU N 0 CD 250 V TBL TT MER CONNECT EF -2 TO PROCESSOR EXHAUST. COORDINATE ALL REQUIREMENTS WITH OWNER AND INSTALL IN STRICT ACCORDANCE WITH MANUFACTURERS REQUIREMENTS AND RECOMMENDATIONS. (SEE DETAIL SHEET M2). 32 25 CF0I, i g CD ✓ . 225 --/ HVAC NOTES 10x10 - �� 1ACKRC O 6 PROVIDE DOUBLE ACOUSTIC TURNING VANES AT ALL 90' TURNS. EY EW.ADN I S-DR 7 ( - 8 -DR 0 LADDER II 1x10 CD 250 II t - 4C TL T. I 1 ALL DUCT DIMENSIONS NOTED INSIDE CLEAR. ALL SUPPLY AND RETURN DUCTWORK SHALL BE SEALED WITH HARDCAST DT5300 3" WIDE TAPE COATED WITH FTA 20 ADHESIVE IN ACCORDANCE WITH SMACNA SEAL CLASS "B" 2 ALL SUPPLY AND RETURN DUCTWORK SHALL HAVE 2" OF EXTERNAL INSULATION. SEE SPECIFICATIONS FOR DETAILS. 3 PROVIDE EXTRACTOR AT ALL BRANCH TAKEOFFS. 4 PROVIDE SPUTTER DAMPER AT ALL SPLITS OF A MAIN. 5 PROVIDE VOLUME DAMPERS ON: ALL BRANCH TAKEOFFS EACH MAIN AFTER A SPLIT ALL BRANCHES TO AN AIR DEVICE RA AND OA DUCTS AT RETURN PLENUMS 7 PROVIDE FLEX CONNECTION OF ALL DUCTWORK TO ALL MECHANICAL UNITS. 8 LOCATE ALL MECHANICAL DEVICES ON ROOF A MINIMUM OF 10' -0" FROM THE EDGE OF ROOF. MAINTAIN 10' -0" CLEAR EXHAUST, FLUE OUTLET OR PLUMBING VENT. 9 COORDINATE DUCTS AND /OR PIPING TO PROVIDE REQUIRED CLEARANCES IN ACCORDANCE W/ NFPA -70 FOR ALL SWITCHBOARDS, ELECTRICAL PANELS, FACP, DISTRIBUTION PANELS, TRANSFER SWITCHES, ETC. 10 DUCT MOUNTED SMOKE DETECTORS SHALL BE INSTALLED AS PER MANUFACTURER'S INSTRUCTIONS. INSTALL WHERE AIR FLOW IS AS LAMINAR AS POSSIBLE. 11 IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE SYSTEMS AND VERIFY DIMENSION CONDITIONS PRIOR TO INSTALLATIONS. 12 ROUTE CONDENSATE LINES TO NEAREST ROOF DRAIN. CD 250 V . • HVAC LEGEND 24x24 CEILING SUPPLY DIFFUSER 24x24, CEILING RETURN REGISTER 12x12 CEILING EXHAUST GRILLE EXISTING THERMOSTAT I MANUAL VOLUME DAMPER NEW DUCTWORK GENERAL NOTE: ALL DRAWINGS ARE DIAGRAMMATIC. ALL LAY -IN CEILING DIFFUSERS AND RETURN GRILLES SHALL BE 24x24 FULL FACE SIZE UNLESS OTHERWISE NOTED (SEE HVAC LEGEND). FOR BRANCH DUCT SIZES AND DIFFUSER/GRILLE NECK SIZES REFER TO SCHEDULE SHEET M2. ALL BRANCH DUCTS SHALL BE TAPPED FROM SIDE OF MAIN DUCT PER DETAIL SHEET M2. 28x14 RETURN DUCT UP TO RTU -1 1-4VAC FLOOR FLAN 1 /4° = l'- 0' FILE CCP\' demand that the Plan Check , approvals ere .3.",t to errors and omissions any approval of 5 does not authorize the viol-Ann ' of ar , y 'tad code or ordinance. Rece:■t, of con t { i`'s copy of approved plans a_i;no.viedgerd. D / T'fC''tacffLA PARATE PIS OUT FEED FOR: f':M AL it L V� hate s- - a�► Pend No. �_ _00 M ZOOO - zz) Peterson &Associates, Inc. Consulting Engineers 2003 Blair Blvd. Nashville, Tennessee CITY OF TUKWILA APPROVED RECEIVED Cr1V SE TUKHBLA SEP 1 4 2000 PERMIT CENTER CV o i 4 r imiwe .B ff U 1- iii .!mot Z E l W VD 0 a 1--- Sheet. Title NVAC FLOOR PLAN 0 Project No: 101.50 Drawn 15y: J.MYERS'. Checked 8y OGG. Sca lei AS NOTED Date:,' 120.00 ROOFTOP UNIT SCHEDULE (ELECTRIC HEAT) MARK RTU -1 CFM RANGE BRANCH DUCT SIZE ALTERNATE DUCT SIZE TONAGE 61/4 CFM RANGE BRANCH DUCT SIZE ALTERNATE DUCT SIZE CFM 2500 UP TO 95 6x6 6 "0 OUTSIDE AIR CFM 375 UP TO 80 8x6 6 "8 EXT S.P. 1.00 96 -225 10x6 8 "0 AMB. AIR TEMP. 95 81 -140 10x6 8 "0 COOLING DATA ENT AIR DB g 80 10 "0 10 ° 0 SEE PLAN WB F 67 10 ° 0 10"0 SEE PLAN SEN. MBH 517 12 "0 12 "0 SEE PLAN TOTAL MBH 75.0 10 "0 1 0°0 SEE PLAN HEATING DATA ENT. AIR ° F 70 1 4 0 SEE PLAN 301 -480 KW 6.75 1 2 °0 SEE PLAN 701 -800 STAGES 1 15 "0 SEE PLAN 481 -700 VOLTS /PHASE 208/3 14 "0 SEE PLAN EVAP. FAN HP 10 ' 701 -950 EVAP. FAN FLA 5.9 1 6 "0 SEE PLAN COMP_ RLA 21.8 951 -1300 COND. FAN FLA. 3.4 24x24 SEE PLAN MCA 36.6 1301 -2000 MOCP 50 36x24 SEE PLAN MANUFACTURER TRANE 2001 -2800 MODEL NO. TCD -07503 48x24 SEE PLAN WEIGHT 850 REMARKS ALL BRANCH DUCT, REGISTER & GRILLE SCHEDULE CEILING DIFFUSERS RETURN /EXHAUST REGISTERS & GRILLES CFM RANGE BRANCH DUCT SIZE ALTERNATE DUCT SIZE NECK SIZE FACE SIZE CFM RANGE BRANCH DUCT SIZE ALTERNATE DUCT SIZE NECK SIZE FACE SIZE UP TO 95 6x6 6 "0 CO SEE PLAN UP TO 80 8x6 6 "8 6 "0 SEE PLAN 96 -225 10x6 8 "0 8 "0 SEE PLAN 81 -140 10x6 8 "0 8 "0 SEE PLAN 226 -325 10x8 10 "0 10 ° 0 SEE PLAN 141 -220 12x6 10 ° 0 10"0 SEE PLAN 326 -475 14x10 12 "0 12 "0 SEE PLAN 221 -300 14x8 10 "0 1 0°0 SEE PLAN 476 -700 16x10 14 "0 1 4 0 SEE PLAN 301 -480 26x6 OR 18x8 12 "0 1 2 °0 SEE PLAN 701 -800 18x10 15 "0 15 "0 SEE PLAN 481 -700 20x10 14 ° 0 14 "0 SEE PLAN 701 -950 20x12 OR 26x10 16"0 1 6 "0 SEE PLAN 951 -1300 28x10 N/A 24x24 SEE PLAN 1301 -2000 26x14 OR 38x10 N/A 36x24 SEE PLAN 2001 -2800 58x10 OR 26x18 N/A 48x24 SEE PLAN FAN SCHEDULE MARK EF -1 EF -1 SERVICE 7LT PROC. TYPE ROOF ROOF CFM 125 325 SP -iN H2O 0.25 0.375 MOTOR HP 1/4 1/4 ELECTRICAL 120/1 120/1 MANUFACTURER GREENHECK GREENHECK MODEL NO. GB -70 -4 GB -100 -4 INTERLOCK WfTH SWITCH (SEE ELEC) SWITCH (SEE ELEC) ACCESSORIES ALL ALL ROOF FLOOR NTS, IJ SIZES ARE BY THIS SCHEDULE UNLESS NOTED OTHERWISE. DIFFUSERS ARE 4 -WAY BLOW UNLESS NOTED AS 3 -WAY OR 2 -WAY. GO TO NEXT LARGER NECK SIZE FOR 2 -WAY OR 3 -WAY DIFFUSERS. 2. USE RETURN /EXHAUST REGISTER AND DIFFUSERS WITH OBD IN DRYWALL OR INACCESSIBLE CEIUNGS. USE RETURN /EXHAUST GRILLES AND DIFFUSERS WITHOUT OBD IN LAY -IN OR ACCESSIBLE CEIUNGS. WHERE GRILLES AND DIFFUSERS WITHOUT OBD ARE USED, INSTALL MVD IN BRANCH DUCT OR USE SPIN -IN FITTING W /MVD IN BRANCH DUCT. 3. RETURN AND EXHAUST GRILLES ARE BASED ON A MAXIMUM OF 450 FPM AND A MIN. OF 72% FREE AREA. 4. BRANCH DUCT SIZES ARE BY THIS SCHEDULE. #10 X 3/4" SELF- TAPPING CADMIUM PLATED SHEET METAL SCREWS TO ANCHOR STRAPS TO DUCT AND JOISTS. ALL STRAPS TO RE TIGHT AGAINST DUCT AND SUPPORT MEMBERS. (TYPICAL) HANGER STRAPS NO POP RIVETS ALLOWED 25-0" MIN. 1 FASTEN RIGID DUCT TO SPIN -IN FITTING /TAP W/ SHEET METAL SCREWS n 3' MIN. PLUMBING VENT NTS OA INTAKE 25-0" MIN. EXHAUST FAN /VENT WRAP ALL MAIN AND BRANCH DUCTS AND COVER CONNECTIONS WITH DUCT WRAP. SEE SPECIFICATIONS. SHEET METAL SPIN --IN OR SADDLE TAP W /EXTRACTOR CONE BALANCE DAMPER WITH LOCKING QUADRANT OA INTAKE LOCATION DETAIL ROUND RIGID DUCT 12" WIDE 24 GA. SHIELD 2 X 24" GA STRAP PROVIDE 3/4" HAT CHANNELS, BOTH O DIFFUSER SUPPORT TYPICAL DIFFUSER CONNECTION DETAIL NOTE: NO PLUMBING PIPING OR DUCTWORK SHALL BE ROUTED ABOVE AN ELECTRICAL PANEL. CEILING FINISHED FLOOR 5. ALL LAY -IN DIFFUSERS /RETURN GRILLES SHALL BE 24x24 OR REGARDLESS OF CFM. 6. CEIUNG DIFFUSER CD: METALAIRE SERIES 5800 OFF -WHITE FINISH 7. CEILING RETURN GRILLE RG: METALAIRE MODEL CC5 OFF - WHITE FINISH 8. EXHAUST GRILLE EG: METALAIRE MODEL CC5 OFF -WHITE FINISH S ir [iti!itiv tW Oi!1!1!1!i!i!I Wi!i!O !i! III i!Al l!i! K r faTMUTi fjlilifitd!I►11 .• s CEILING DIFFUSER INSULATED METAL FLEX DUCT. SEE SPECS. NO SAGS OR SHARP 90' TURNS ALLOWED EXCEPT AT DIFFUSER CONNECTION. LIMIT RUN TO 3' -0 LONG. ` ,1 WIRE HANGER TO STRUCTURE STAINLESS STEEL q�F,;RATED BAND ELEC. PANEL IAN. 2' -6" FRONT VIEW ELEC. PANEL FOOTPRINT TO STRUCTURE OR 25 -0 ". 3' -0" SIDE VIEW ELECTRICAL CLEARANCE ROUN I�ATE q R ELEC. PANEL CONDENSER INLET ROOF MEMBRANE OR METAL ROOF CONDENSER FAN DISCHARGE INSULATION METAL DECKING . FAF' HUNTED SOLID STATE SPEED CONTROLLER 2. BACK DRAFT DAMPER 3. INTERNAL DISCONNECT SWITCH 4 . FACTORY ROOF CURB TYPICAL ROOFTOP UNIT DETAIL NTS EXHAUST FAN 'Lemma' � e y//�py y �ypy r ATM% if WAWA I WAVY SEE PLANS FOR DUCT ROUTING & CONNECTION TO IN- LINE /ROOFTOP EXHAUST SYSTEMS 04 SMOKE DETECTOR BAR JOIST (SEE STRUCTURAL) 6 "0 GALV. `DUCT OUTSIDE MR FLEXIBLE CONNECTOR (SUPPLY & RETURN) COUNTER FLASHING RAISED CANT STRIP ROOF CURB SMOKE DETECTOR - STUB CO DUCT 12" BELOW OLD. & REDUCE TO 4 "0 DUCT r� PROCESSING EQUIPMENT ATTACH W/ PANDUIT STRAP MN s a se ww FLEXIBLE HANGER NOTE: CONTRACTOR TO COORDINATE WITH TENANT TECHNICIAN FOR "ROUTING FINAL CONNECTION TO PROCESSOR EQUIPMENT. 4 ° 0 FLEX DUCT 3 ° 0 HOC". -UP AT UNIT PROCESSOR EXHAUST CONNECTION DETAIL 1. PROVIDE ROOF CURB 2. PROVIDE 2 THICK FILTERS 3. PROVIDE ELECTRONIC PROGRAMMABLE THERMOSTAT 4_ PROVIDE LOW AMBIENT CONTROLS 5. PROVIDE SMOKE DETECTORS IN SUPPLY & RETURN DUCTS 6. PROVIDE HAIL GUARD ON CONDENSER COIL 7. ROUTE CONDENSATE TO NEAREST ROOF DRAIN 8. MECHANICAL CONTRACTOR SHALL CONFIRM ELECTRICAL REQUIREMENTS WITH ELECTRICAL CONTRACTOR 9. PROVIDE MANUAL 0_A DAMPER REMOVABLE HOUSING UNFUSED DISCONNECT SWITCH BIRD SCREEN BACKDRAFT DAMPER ROOFING, FLASHING AND CANT BY GEN_ CONT'R ROOF INSULATION ROOF DECK INSULATE OUTSIDE OF DUCTWORK 2" DRIP PAN SEAL JOINTS WATERTIGHT /I - IIIIIIIIIIIIIIII / A %IIIIIIIIIIIIIIIh POWER ROOF VENTILATOR INSULATED PREFAB CURB ROOF OPENING & ANGLE REINFORCING BY GEN. CONT'R POWER ROOF VENTILATOR CURB & DRIP PAN DETAIL NTS Peterson & Associates, Inc. Consulting Engineers 2003 .Blair Blvd. Nashville, Tennessee 615 292 7336 CFIYOFTUKWILA SEP 1 4 2000 a8RMITCENTEI i 33 MUSIC SQ.' W., 106A NASF+VILLE, TENNESSEE 31203 615221.1209 FAX 615228.1216 I t Revisions Sheet Title VAC SCHEDULES 4 DETAILS sr Protect No: Drawn By: Checked 134: Scale: Date: Filename: T 101.50 JMYEIRS DCaC AS NOTED 120.00 H,V,A,C. CALCULATI ❑N FORM BUILDING 'G2' S U M E R SPACE 76 ° F @ 50% R.H. OUTSIDE 84 °F db/ 68 wb HEATING SPACE 72 ° F OUTSIDE E1° ROOF "U" = 0.09 CLTD = 68 HEAT LOSS SENSIBLE LATENT HEAT GAIN HEAT GAIN ITEM QUANTITY FACTOR BTUH FACTOR BTUH FACTOR BTUH L ROOF AREA GLA D O SOY T. 459 .y A A0 5.33 I p CC t - a CllRRIDQ2 WALL I , � .R SQfT. 7.65 3 0 0.75 q c L -, 3. LBJISIDE WALL IV ,I hl SOFT. 1734 N/ 1 XE Wi, 4. LIGHTING BE ) E CONNECTION j 5 9 K. V. - 3413 . 5;,,,) , 5. PEOPLE GLA /100 = CD PEOPLE 315 (._ 6. APPLIANCES SEE APPLIANCE CALC FORM - N I i 7. LWTSIDE AIR GLA A4 2 CFM /SQ.FT =' CFM 55 .D, 0 3 _ 8.64 3 Ty 5 C B. FAN FXITOIRS 1 _ 0 H.P. 2545 ) y , 9 Go o) TOTALS - 1 R,.) 9 TOTAL .- (SENSIBLE + LATENT). BTUH . ,I 5 y ' 2545 )iE XE LIGHTING KV ENTRY SHALL MATCH FROM THE ELECTRIC LOAD SUMMARY EB 'ELECTRICAL DATA FORMS" )K WALL FACTOR OUTSIDE WALLS NORTH= 4.08 EAST = 8.84 SOUTH= 6.46 WEST = 6.46 REMARKS H,V,A,C, CALCULATI ❑N E❑RM PHASE I SUMMER SPACE 76 F @ 50% R.H. OUTSIDE 84 F db/ 68 Fwb HEATING SPACE 72 F OUTSIDE 21 F ROOF 'U " = 0.08 CLTD = 68 HEAT LOSS SENSIBLE LATENT HEAT GAIN HEAT GAIN ITEM QUANTITY FACTOR BTUH FACTOR BTUH FACTOR BTUH 1. ROOF AREA G.L.A. SOFT. 4.28 5.71 - - - 2. CORRIDOR WALL SOFT. 4.76 2.52 - 3 OUTSIDE WALL SOFT. 17.34 XE 4. LIGHTING XE III CONNECTION K.V. 3413 L. PEOPLE GLA /100 = PEOPLE - -.- -._. 250 200 6. APPLIANCES SEE APPLIANCE CALC FORM - 7. OUTSIDE AIR GLA x .2 CFM/SOFT.. CFM 55.08 8.64 6.80 8. FAN MOTORS H.P. 2545 TOTALS TOTAL = (SENSIBLE + LATENT). BTUH COOLING CFM: SENSIBLE BTUH = CFM 1.08x20' &T .- X( )I( LIGHTING KW ENTRY SHALL MATCH FROM THE ELECTRIC LOAD SUMMARY ON 'ELECTRICAL DATA FORMS' XE WALL FACTOR OUTSIDE WALLS NORTH= 3.40 REMARKS. EAST =10.88 SOUTH= 5.44 WEST = 3.74. KEY PLAN NO SCALE CENIERDNE OF JOIST DOUBLE NUT WITH X T O.D. 1/4' THIC WASHER (TYPO 1/4' MIN. DWAETER CONTINUOUS THREADED RW. (TYPO ISOLATOR -MASON INDUSTRIES TIPS JON SPRING HANGERS SIZE EACH HANGER ASSEMBLY a FOR ONT. MIN. CAPACITY OF OF THE INSTAUED WE MAX. DOUBLE %4' THICK waNEa OYP) MIN. 2, ANGLE SUPPORT SECURE UNIT REOUIREME S 5'-U O.C. MAX. 70 ANGLES ATTACH TO EACH JOIST. N4IE1 METHOD #1 USE THIS METHOD ONLY WHEN SPACE EXISTS BETWEEN ANGLES FORMING BOTTOM CHORD. JOIST PANEL POINT AN. TERMINAL BOX ETC. vir WHEN IWIGER ROD PROJECTS BEYOND JOST MORE THAN 6' EXTEND ANGLE TO NEXT JOST METHOD #2 F1EID RE PRO VERIFY tAN LORDS APPROVED LOCATION OF H.VAC. EQUIPMENT WITH LANDLORD'S REPRESENTATIVE BEFO SEE STRUCTURE DRAWINGS FOR H.VAC. EQUIPMENT AND REINFORCED JOIST LOCATIONS FOR EQUIPMENT OVER 2000. SOB OF SIRUCNRLL SUPPORTS (RODS. ANGLE ETC.) ARE MINIMUMS AND SHALL BE MEMBER MO TENANT OR TENANT CONTRACT AS REQUIRED FIXi PROPER SUPPORT AND STRUCIMTAI WIEGRItt. DO NOT DRILL HOLES W EXISTING STRUCTURAL MEMBERS UNLESS APPROVED BY AWDLORD IN WRMNG. UNLESS INDICATED OTHERWISE ON STRUCTURAL DRAWINGS: A UNITS UP TO 1880 LBS. TOTAL WEIGHT SHALL BE SUPPORTED ON A MINIMUM OF TWO (2) JOISTS B UNITS A MIMMUM OF GREATER T iB80 (3BS: OIST I TRJT S. IB LESS THAN MOO S. TOTAL WEIGHT SHALL BE SUPPORTED ON NAN THREE ) J C MAXIMUM TOTAL ROCK OF ONE UNIT 6 MOO LBS. EQUIPMENT SUPPORT DETAIL 0 N.T.S. T1-35 C ANGLE TO JOIST. BOIT CHORD OF JOIST PHASE I A HVAC 1. B. PLUMBING SOUTHCENTER MALL PHASE I SYSTEM DESCRIPTIONS TENANT TO FURNISH AND INSTALL SPLIT SYSTEM HEATING AND AIR CONDITIONING UNIT(S), SIZED PER SENSIBLE/TOTAL CALCULATION FORM. HEATING SHALL BE ELECTRIC FOR PHASE I TENANTS. GAS IS NOT AVAILABLE. TENANT SHALL CONNECT TO LANDLORD PROVIDED OUTSIDE AR DUCT WHERE PROVIDED FOR MINIMUM FRESH. AIR REQUIREMENTS, OR INSTALL AN OUTDOOR AIR INTAKE THROUGH ROOF. INSULATE DUCTWORK PER LANDLORD'S REQUIREMENTS. WHERE TENANT'S ELECTRIC HEATING REQUIREMENT EXCEEDS 6 KW A HEAT PUMP IS NEEDED AS PER WASHINGTON STATE 1994 ENERGY CODE. 2. TENANTS SHALL INSTALL TOILET ROOM INCLUDING EXHAUST FAN AND EXHAUST DUCT UP TO ROOF EXHAUSTER. T. TENANT SHALL FURNISH AND INSTALL A COMPLETE TOILET ROOM WITHIN THE LEASED PREMISES. LANDLORD HAS PROVIDED SANITARY AND DOMESTIC WATER CONNECTIONS FOR TENANTS TO UTILIZE. TENANTS SHALL RUN A 4' VENT THRU ROOF. TOILET ROOMS SHALL CONFORM WITH ADA REQUIREMENTS AND THE REQUIREMENTS OF THE LANDLORD. 2. WATER METER IS REQUIRED BY ALL TENANTS. TENANT TO PURCHASE WATER METER FROM LOCAL UTILITY AND INSTALL PER UTILITY COMPANY REQUIREMENTS. PROVIDE METER WITH REMOTE READOUT AS REQUIRED. ALL INSTALLED EQUIPMENT, ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. MANUFACTURER C. SPRINKLER D. TOILET EXHAUST FAN SPECIFICATION MODEL STATIC PRESS. "WC RPM TENANT SHALL FURNISH AND INSTALL A SPRINKLER SYSTEM WITHIN THE LEASED PREMISES FROM THE LANDLORD'S CONNECTION POINT. 2. SPRINKLER IS REQUIRED ABOVE CEILING AT ALL ELECTRIC MOTORS AND IN AHU MIXING BOX. 3. ALL DESIGN SHALL BE APPROVED BY ALL AUTHORITIES HAVING JURISDICTION, THE LANDLORD AND FACTORY MUTUAL THE LANDLORD'S UNDERWRITER. IS: FACTORY MUTUAL DISTRICT OFFICE 10900 NE 4th ST. SUITE 700 P.O. BOX 96077 BELLEVUE, WA (206)- 454 -3931 98009 -9677 SMOKE DETECTION SYSTEMS 1. TENANT SHALL INSTALL A SMOKE DETECTOR IN THE SUPPLY AIR SECTION OF THE AIR HANDLING UNIT(S). 2. UPON DETECTION OF TENANT SMOKE THE SMOKE DETECTOR SHALL SHUT DOWN THE HVAC SYSTEM(S) AND REPORT TO AN UNDERWRITER'S LABORATORIES LISTED CENTRAL STATION MONITOR. 3. PROVIDE REM' - ITE TEST - ALARM -R456T SWITCH /LIGHTS AT REAR DOUR FOR SMOKE. DETECTOR & LED. IN SALES AREA CEILING TO NOTIFY M.G.R. WHEN SMOKE DETECTOR IS AGTIVATEO. H,V,A,C, SCHEDULES MANUFACTURER E.E.R. RATING CONDENSING UNIT ACCESSORIES: LOW LEAKAGE SEALS ON O.A. LOW VELOCITY FILTERS REMARKS: SPLIT SYSTEM SPECIFICATIONS SATURATED SUCTION TEMP F SATURATED COND. TEMP F AIR HANDLING UNIT MODEL NO. MODEL NO. WEIGHT WEIGHT VOLTS /PHASE /HZ VOLTS /PHASE /HZ COMP PWR INPUT KW CFM TOTAL COOLING BTUH TOTAL S.P. "WC FAN RPM HP BHP DAMPERS REFRIGERANT AIR ENTERING CONDENSER Fdb EVAPORATOR COIL MODEL NO. AIR ENT. COIL Fdb Fwb AIR LVG. COIL Fdb Fwb ROWS CIRC_FINS/" TOTAL COOLING BTUH SENSIBLE COOLING BTUH PRESSURE DROP WC COIL FACE AREA SOFT. FACE VELOCITY FPM MANUFACTURER MODEL NO. ACCESSORIES FUSED DISCONNECT SWITCH 24V TRANSFORMER SEPARATE ELECTRIC DUCT HEATER SPECIFICATION KW STEPS VOLTS /PHASE /HZ SLIP -IN ZERO CLEARANCE THERMOSTAT MAGNETIC CONTACTORS OTHERS WATTS /HP V /PH /HZ KEY PLAN NO SCALE \W1 A. HVAC C. TENANT TO FURNISH AND INSTALL ROOF TOP UNITS) SIZED PER 1. SENSIBLE/TOTAL CALCULATION FORM. HEATING MAY BE GAS DR ELECTRIC FOR BUILDING "G -2' TENANTS. GAS IS AVAILABLE ON ROOF. TENANT SHALL OBTAIN GAS METER FROM LOCAL UTILITY AND INSTALL PER UTILITY. COMPANY REQUIREMENTS. SEE LANDLORD'S DRAWINGS FOR GAS METER LOCATION. COOLING SHALL BE ELECTRIC. LOW AMBIENT OR AN ECONOMIZER CYCLE IS REQUIRED ON ALL RTU' S. 2. TENANT SHALL FURNISH AND INSTALL A SMOKE RELIEF. FANS SHALL BE SIZED AS INDICATED ON CALCULATION FORM. TENANTS WITH ECONOMIZER MAY UTILIZE HVAC REUEF AS SMOKE RELIEF. BUILDING SOUTHCENTER MALL BUILDING 'G2' SYSTEM DESCRIPTIONS B. PLUMBING 1. LANDLORD HAS PROVIDED SANITARY, GAS AND DOMESTIC WATER SERVICES FOR TENANTS TO UTILIZE. SEE LANDLORD'S DRAWINGS FOR LOCATION OF SERVICES. 2. WATER METER IS REQUIRED BY ALL TENANTS. TENANT TO PURCHASE WATER METER FROM LOCAL UTIUTY AND INSTALL PER 2 UTILITY COMPANY REQUIPEMENTS. PROVIDE METER WITH REMOTE READOUT AS REQUIRED. ALL INSTALLED EQUIPMENT, ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. 1. H,V,A,C. SCHEDULES MANUFACTURER T2 A MF MODEL op -off S VOLTS /PHASE /HERTZ a0$ 3/C p EER RATING 11. O TOTAL WT. RT LBS. EVAPORATOR FAN PERFORMANCE CFM a5� EXTERNAL S.P. I . 'WC MOTOR H.P. ).G) HP OUTSIDE AIR <MINI CFM ACCESSORIES ECONOMIZER (Y S) HVAC RELIEF •WIT DOWNTURN PL F' FULL PERIMETER CURB THROWAWAY FILTERS (RTU) SPECIFICATIONS A ENTERING CAPACITY CONDENSER CO 905° IOFdb AIR ENTERING EVAPORATOR$o Fdb/ C 7 Fwb TOTAL COOLING CAPACITY -- 7.S..<2. BTUH SENSIBLE COOLING CAPACITY 4.t ') BTUH COMPRESSOR INPUT KW HEATING CAP TY GAS (YES) NO NPUT OUTPUT OR LOW AMBIENT CONTROL TO 0 F uyau.) (NOT (PWR) HP ANTI -SHORT CYCLE TIMER AUTO CHANGEOVER T'STAT WITH CRANKCASE HEATER HEAT - COOL - AUTO - OFF AND 5 - YR. COMP. WARRANTY FAN- AUTO-ON SWITCHES IN SUB - BASE ROOFTOP UNIT SEPARATE POWERED HVAC /SMOKE RELIEF FAN SPECIFICATION MANUFACTURER CFM V /PH /HZ HP 'WC DRIVE (DIRECT)OR(BELT) RPM MODEL STATIC PRESSURE MINIMUM CFM CALCULATION LEASABLE AREA AT 1.5 CFM /SQ.FT. _ CFM NOTE: MINIMUM STATIC PRESSURE SHALL BE .25' W.C. SPRINKLER TENANT SHALL FURNISH AND INSTALL A SPRINKLER SYSTEM WITHIN THE LEASED PREMISES FROM THE LANDLORD'S CONNECTION POINT. 2. SPRINKLER IS REQUIRED ABOVE CEILING AT ALL ELECTRIC MOTORS AND IN AHU MIXING BOX. 3. ALL DESIGN SHALL BE APPROVED BY ALL AUTHORITIES HAVING JURISDICTION, THE LANDLORD AND FACTORY MUTUAL. THE LANDLORD'S UNDERWRITER IS: FACTORY MUTUAL DISTRICT OFFICE 10900 NE 4th ST. SUITE 700 P.O. 80X 96077 BELLEVUE, WA. (206)- 454 -3931 98009 -9677 SMOKE DETECTION SYSTEMS TENANT SHALL INSTALL A SMOKE DETECTOR IN THE SUPPLY AIR SECTION OF THE ROOF TOP UNIT(S). UPON DETECTION OF TENANT SMOKE THE SMOKE DETECTOR SHALL SHUT DOWN THE HVAC SYSTEM(S), SOUND AN AUDIOVISUAL. ALARM HORN LOCATED AT THE FRONT OF THE STORE AND REPORT TO AN UNDERWRITER'S LABORATORIES USTED CENTRAL STATION MONITOR. 3. PROVIDE REMOTE TEST -ALARM -RESET SWITCH / UGHTS AT REAR DOOR FOR SMOKE DETECTION SYSTEM. SOUTHCENTER MECHANICAL DETAILS AND SPECIFICATIONS Sheet I of 6 DRAW91 BY: REMSED '.BY:. RECEIVED CITY OF TUKWILA FYENAME SEASU, - WASHINGTON 5uI1'E POI - UNIT NUMBER Ikkjn A1'uK p pt e DBA . THIS SHEET & TTO.OI MUST BE INCLUDED AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS AND FOR BUILDING PERMITS The Richard E. Jacobs Group REVISED REVISED I. REVISED REN90NS DATE JOB NUMBER DA 4/20/98 1/15/A6 6/13/95 H,V,A,C; SCHEDULES ROOFTOP UNIT (RTU) SPECIFICATIONS MANUFACTURER COOLING CAPACITY (AT AR. CONDITIONS) MODEL AIR ENTERING CONDENSER 95 Fdb VOLTS /PHASE /HERTZ AIR ENTERING EVAPORATOR Fdb/ Fwb EER RATING TOTAL COOLING CAPACITY BTUH TOTAL VT. LBS. SENSIBLE COOLING CAPACITY BTUH EVAPORATOR FAN PERFORMANCE COMPRESSOR INPUT KW CFM HEATING CAPACITY EXTERNAL SP. 'VC GAS (YES) (NO) MOTOR HP. HP INPUT OUTSIDE AIR (MIN) CFM ACCESSORIES OUTPUT ECONOMIZER (YES) (NO) OR LOW AMBIENT CONTROL TO 0 F (YES) (NO) HVAC RELIEF (GRAVITY) (PWR) HP DOWNTURN PLENUM ANTI -SHORT CYCLE TIMER AUTO- CHANGEOVER T'STAT WITH FULL PERIMETER CURB CRANKCASE HEATER HEAT - COOL - AUTO -OFF AND THROWAWAY FILTERS 5 -YR. COMP. WARRANTY FAN - AUTO -ON- SWITCHES IN SUB -BASE KITCHEN EXHAUST FAN MANUFACTURER MOTOR H.P. CFM POWER V/ HZ PH MODEL FAN R.P.M. E.S.P. DRIVE BELT MOUNTING (CURB) SEPARATE POWERED HVAC /SMOKE RELIEF FAN SPECIFICATION MANUFACTURER S EEM TIC HP MODEL STATIC PRESSURE 'WC DRIVE (DIRECT)DR(BELT) RPM MINIMUM CFM CALCULATIONS LEASABLE AREA x 1.5 CFM /SQ.FT. = CFM NOTE: MINIMUM STATIC PRESSURE SHALL BE .25' W.C. H,V,A,C, SCHEDULES ROOFTOP UNIT (RTU) SPECIFICATIONS MANUFACTURER COOLING CAPACITY MODEL AIR ENTERING CONDENSER Fdb VOLTS /PHASE /HERTZ AIR ENTERING EVAPORATOR Fdb/ -BTUH EER RATING TOTAL COOLING CAPACITY BTUH TOTAL WT. LBS. SENSIBLE COOLING CAPACITY BTUH EVAPORATOR FAN PERFORMANCE COMPRESSOR INPUT KW CFM HEATING CAPACITY EXTERNAL S.P. 'WC ELECTRIC (YES) (NO) GAS (YES) (NO) MOTOR H,P. HP KW INPUT. OUTSIDE AIR (MIND CFM STEPS OUTPUT ACCESSORIES ECONOMIZER (YES) (NO) OR LOW AMBIENT CONTROL TO 0 F (YES) (NO) HVAC RELIEF (GRAVITY) (PWR) HP DOWNTURN PLENUM ANTI -SHORT CYCLE TIMER AUTO - CHANGEOVER T'STAT WITH FULL PERIMETER CURB CRANKCASE HEATER HEAT -COOL -AUTO -OFF AND THROWAWAY FILTERS 5 -YR. CORP. WARRANTY FAN - AUTO -ON- SWITCHES IN SUB -BASE TOILET EXHAUST FAN SPECIFICATION MANUFACTURER CFM WATTS /HP V/PH /HZ MODEL STATIC PRESS. "WC RPM SQ.FT. SEPARATE POWERED HVAC /SMOKE RELIEF FAN SPECIFICATION MANUFACTURER CFM V /PH /HZ HP MODEL STATIC PRESSURE 'WC DRIVE (DIRECT)OR(BELT) RPM MINIMUM CFM CALCULATIONS LEASABLE AREA x 1.5 CFM/SQ.FT. = CFM NOTE: MINIMUM STATIC PRESSURE SHALL BE 25' W.C. H,V,A.C, CALCULATI ❑N FORM PHASE II SUMMER SPACE 76 °F @ 505 R.H. OUTSIDE 84 °F db/ 68 wb HEATING SPACE 72 °F OUTSIDE 21° F ROOF "U" = 0.05 CLTD = 68 HEAT LOSS `ENSIBLE LATENT HEAT GAIN HEAT GAIN ITEM QUANTITY FACTOR BTUH FACTOR BTUH FACTOR BTUH 1. ROOF AREA G.L.A. SOFT. 2.55 3.4 2. CORRIDOR WALL SQ.FT. 4.76 2.52 3. OUTSIDE WALL SQ.FT. 2.30 : )K - - 4. LIGHTING )I( X. CONNECTION K.W. > 3413 3413 5. PEOPLE GLA /100 = PEOPLE - 315 325 6. APPLIANCES SEE APPLIANCE CALC FORM 6. APPLIANCES SEE APPLIANCE CALL FORM 7. OUTSIDE AIR GLA x .2 CFM /SOFT= CFM 55.08 ® 8.64 6.80 8. FAN MOTORS HP. 2545 8. FAN MOTORS TOTALS 2545 TOTAL = (SENSIBLE + LATENT)= BTUH COOLING ')IE)1( LIGHTING KW ENTRY SHALL MATCH FROM THE ELECTRIC LOAD SUMMARY ON 'ELECTRICAL DATA FORMS' * WALL FACTOR OUTSIDE WALLS NORTH= 0.50 EAST = 1.00 SOUTH= 0.75 VEST = 1.00 REMARKS, H.V,A,C, CALCULATI ❑N FORM FOOD COURT SUMMER SPACE 76 ° F @ 505 R.H. OUTSIDE 84 °F db/ 68°F wb HEATING SPACE 72 °F OUTSIDE 21 ° F ROOF if = 0.09 CLTD = 68 HEAT LOSS SENSIBLE LATENT HEAT GAIN HEAT GAIN ITEM QUANTITY FACTOR BTUH FACTOR BTUH FACTOR BTUH L ROOF' AREA G.L.A. SOFT. 4.59 5.33 a CDRRIO[R WALL SOFT. 7.65 0.75 3. OUTSIDE WALL SOFT. 17.34 • ME 4. LIGHTING SE NE CONNECTION K.V. 3413 5. PEOPLE GLA/100 = PEOPLE 315 325 6. APPLIANCES SEE APPLIANCE CALL FORM 7. OUTSIDE AIR GLA x 2 CFM/SQ.FT. CFM 55.08 8.64 6.80 8. FAN MOTORS HP. 2545 TOTALS TOTAL = (SENSIBLE + LATENT)= BTUH COILING REME LIGHTING KY ENTRY SHALL MATCH FROM THE ELECTRIC LOAD )K WALL SUMMARY ON 'ELECTRICAL DATA FORMS' FACTOR OUTSIDE WALLS NORTH= 4.08 EAST = 8,84 SOUTH= 6.46 WEST = 6.46 REMARKS, !111111111$ PHASE II t I IrJ3 ! ; - / ll11f61kil FOOD COURT SEAZLE, WASHINGTON MECHANICAL DETAILS AND SPECIFICATIONS Sheet 2 of 6 UNIT NUMBER me figuRe P DPL4 DBA SEARS KEY PLAN NO SCALE 65RVYN'S A HVAC PLUMBING SOUTHCENTER MALL PHASE II SYSTEM DESCRIPTIONS TENANT TO FURNISH AND INSTALL ROOF TOP UNIT(S) SIZED PER SENSIBLE/TOTAL CALCULATION FORM. HEATING MAY BE GAS OR ELECTRIC FOR PHASE 0 TENANTS. GAS IS AVAILABLE ON ROOF. TENANT SHALL OBTAIN GAS METER FROM LOCAL DOUG AND MSTALL PER UTILITY COMPANY REQUIREMENTS. TENANT SHALL ROUTE GAS SERVICE TO THEIR SPACE AND EQUIPMENT WITHIN THEIR SPACE. SEE LANDLORD'S DRAWINGS FOR GAS SERVICE LOCATION. COOLING SHALL BE ELECTRIC. LOW AMBIENT CONTROL OR AN ECONOMIZER CYCLE IS REQUIRED ON ALL RTU'S. TENANTS SHALL INSTALL TOILET ROOM INCLUDING EXHAUST FAN WITH EXHAUST DUCT TO LANDLORD PROVIDED CENTRAL TOILET EXHAUST SYSTEM. 1. TENANT SHALL FURNISH AND INSTALL A COMPLETE TOILET ROOM D WITHIN THE LEASED PREMISES. LANDLORD HAS PROVIDED SANITARY AND DOMESTIC WATER CONNECTIONS FOR TENANTS TO UTILIZE. TENANTS SHALL RUN A VENT TO LANDLORD'S VENT SYSTEM. TOILET ROOMS SHALL CONFORM WITH ADA REQUIREMENTS • AND THE REQUIREMENTS OF THE LANDLORD. 2. WATER METER IS REQUIRED BY ALL LARGE WATER USING TENANTS. TENANT TO PURCHASE WATER METER AND INSTALL PER 2 LANDLORD'S REQUIREMENTS. ALL INSTALLED EQUIPMENT, ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. C. SPRINKLER TENANT SHALL FURNISH AND INSTALL A SPRINKLER SYSTEM WITHIN THE LEASED PREMISES FROM THE LANDLORD'S CONNECTION POINT. 2. ALL DESIGN SHALL BE APPROVED BY ALL AUTHORITIES HAVING JURISDICTION. THE LANDLORD AND FACTORY MUTUAL THE LANDLORD'S UNDERWRITER IS: FACTORY MUTUAL DISTRICT OFFICE 10900 NE 4th ST. SUITE 700 P.O. BOX 96077 BELLEVUE, WA. (206)- 454 -3931 98009 -9677 FIRE DETECTION AND SMOKE CONTROL SYSTEMS (FDSCS) TENANT SHALL INSTALL A SMOKE DETECTOR IN THE SUPPLY AIR SECTION OF THE ROOF TOP UNIT(5) AND AT STORE FRONT. AODITTONAL SMOKE DETECTOR'S ARE REQUIRED EVERY 30' -0" OPEN STORE FRONT. TENANTS SHALL FURNISH AND INSTALL A SMOKE RELIEF FAN. TENANTS SHALL FURNISH AND INSTALL A STARTER FOR CONTROL OF THE SMOKE. RELIE` AN. 3. TENANT TO FURNISH AND INSTALL A FIRE DETECTION AND SMOKE CONTROL SYSTEM. ALL COMPONENTS TO BE SAME AS LANDLORD'S EXISTING. INTERFACE BETWEEN LANDLORD'S SYSTEM TO SHUT DOWN TENANTS' HVAC SYSTEM AND ENERGIZE TENANT'S SMOKE RELIEF FAN. SEE TTE DRAWING FOR SCHEMATIC. KEY PLAN NO SCALE . HVAC 1. SOUTHCENTER MALL FOOD COURT SYSTEM DESCRIPTIONS TENANT TO FURNISH AND INSTALL ROOF TOP UNIT(S) SIZED PER SENSIBLE/TOTAL CALCULATION FORM. HEATING SHALL BE GAS FOR FOOD COURT TENANTS. GAS IS AVAILABLE ON ROOF. TENANT SHALL OBTAIN GAS METER FROM LOCAL UTILITY AND INSTALL PER UTILITY COMPANY REQUIREMENTS. SEE LANDLORD'S DRAWINGS FOR GAS METER LOCATION. COOUNG SHALL BE ELECTRIC. LOW AMBIENT CONTROL MUST BE UTILIZED. ECOMOMIZER NOT PERMITTED. 2. TENANT SHALL FURNISH AND INSTALL A SMOKE RELIEF. FANS SHALL BE SIZED AS INDICATED ON CALCULATION FORM. B. PLUMBING D. 1. LANDLORD HAS PROVIDED SANITARY, VENT, GAS AND DOMESTIC 1. WATER SERVICES FOR FOOD COURT TENANTS TO UTIUZE. SEE LANDLORD'S DRAWINGS FOR LOCATION OF SERVICES. 2. 2. WATER METER IS REQUIRED BY ALL FOOD COURT TENANTS. TENANT TO PURCHASE WATER METER FROM LOCAL UTILITY AND INSTALL PER UTILITY COMPANY REQUIREMENTS. PROVIDE METER WITH REMOTE READOUT AS REQUIRED. ALL INSTALLED EQUIPMENT, ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. C. SPRINKLER TENANT SHALL FURNISH AND INSTALL A SPRINKLER SYSTEM WITHIN THE LEASED PREMISES FROM THE LANDLORD'S CONNECTION POINT. 2. ALL DESIGN SHALL BE APPROVED BY ALL AUTHORITIES HAVING JURISDICTION, THE LANDLORD AND FACTORY MUTUAL THE LANDLORD'S UNDERWRITER IS: FACTORY MUTUAL DISTRICT OFFICE 10900 NE 4th ST. SUITE 700 P.O. BOX 96077 BELLEVUE, WA. • (206) - 454 -3931 98009 -9677 SMOKE DETECTION SYSTEMS TENANT SHALL INSTALL A SMOKE DETECTOR IN THE SUPPLY AIR SECTION OF THE ROOF TOP UNIT(S). UPON DETECTION OF TENANT SMOKE THE SMOKE DETECTOR SHALL SHUT DOWN THE HVAC SYSTEM(S), SOUND AN AUDIOVISUAL ALARM HORN LOCATED AT THE FRONT OF THE STORE AND REPORT TO AN UNDERWRITER'S LABORATORIES LISTED CENTRAL STATION MONITOR. PROVIDE REMOTE TEST- ALARM -RESET SWITCH /UGHTS AT REAR DOOR FOR SMOKE DETECTION SYSTEM. HECEIVED rrcH nPTUKWILA THIS SHEET & TTO.OI MUST BE INCLUDED AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS AND FOR BUILDING PERMITS FILE NAME: • The Richard E. Jacobs Group REVISONS REVISED ©' REVISED 4/20/98' 1/T5/98'' �.. REVISED DRAM BY: SCALE: DATE: JOB NUMBER 8/13/95 REVISED BY: _.. DATE GENERAL A ALL YORK SHALL BE PERFORMED IN COFOUTAIE WITH ALL APPLICABLE CODES AND LANDLORD'S MINIMUM REQUIREMENTS AS STATED HEREIN) IN THE LEAS, AND/OR IN THE TENANT. HANUAL CODE REQUIREMENTS, IF MORE RESTRICTIVE THAN LANDLORD REQUIREMENTS, SHALL TAKE PRECEDENCE. AND VICE/VERSA GENERAL AND SPECIAL CONDITIONS OF AIA 201 AND TENANT'S GEERAL CONDITIONS REQUIREMENTS SHALL APPLY UNLESS OTHERVISE NOTED. ALL WORK SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE OF WORK BY THE TENANT AND THE LANDLORD. ALL YORK SHALL BE PERFORMED AS INDICATED EN RAVINGS UNLESS FIELD CONDITIONS REWIRE MINOR CHANGES. TO BE MADE. MINOR CHANGES SHALL BE MALE WITH NO ADDITIONAL COST TO THE TENANT. ACTUAL LOCATIONS OF LANDLORDS SERVICES MOIST BE FIELD VERIFIED: CHANCES TO COFOM TO LANDLORD'S SERVICE LOCATORS SHALL BE MADE AT NO ADDITIONAL DUST TO THE TENANT NND /OR LAMM). MANUFACTURERS' NAMES ON WHICH THIS SPECIFICATION IS BASED INDICATE THE MINIMUM QUALITY' OF PRODUCT REWIRED BY LANDLORD. SUBSTITUTIONS NAY BE MADE TO THOSE SPECIFIED IF DEEMED EQUIVALENT BY LANDLORD. ITEMS NOT SPECIFIED HEREIN. SHALL MET LANDLORD'S APPROVAL IF A CONFLICT OCCURS, T THE LANDLORD SHALL RESOLVE SUCH CONFLICT AND THE TENANT'S. CONTRACTOR SHALL CONFORM TO THE LANDLORD'S DECISION. G. SUBMIT MOP DRAWINGS OF ALL MAJOR EQUIPMENT FOR APPROVAL SUBMITTALS SHALL INCLUDE AIR AND WATER BALANCE REPORTS. H AS BUILT DRAWINGS - PREPARE AND SUBMIT TO LANDLORD MB TB TENANT •AS BUILT DRAWINGS INDICATING THE EXACT LOCATION OF ALL DUCTWORK. PIPING, AND ALL EQUIPMENT. INCLUDING TM EQUIPMENT'S • AS INSTALLED' DEL SIZE(S), MANUFACTURER, MO NUMBERS AND PF.RRIRMAMEERATINGS. SUPPORTS - EQUIPMENT, PIPIT&, DCTVORK, DR ANT OVER ACCESSORY SHALL NOT BE SUPPORTED ERIN LANDUROS CEILING, SOFIT, NEUTRAL PIERS, PIPING, DUCTWORK METAL ROOF DECK, LATERAL BRACING, BRIDGING, OR CONDUIT. ITEMS SHALL ONLY BE SUPPORTED FROM STRUCTURE WHIC.H HAS BEEN APPROVED BY LANDLORD FOR SUPPORT. ALL ROOF WORK, PENETRATIONS AND REPAIRS SMALL BE TOTALLY PERFORMED BY ONLY THOSE ROOFING CONTRACTORS APPROVED BY LANDLORD AND SHALL BE PERFORMED AT THE TENANT'S EXPENSE INSTALLATION OF ALL ROOF MO.7ITED EQUIPMENT SHALL BE COORDINATED WITH LANDLORD'S DESIGNATED REPRESENTATIVE. TENANT'S CONTRACTOR SHALL PAY FOR ALL FEES ASSOCIATED WITH THE CONSTRUCTION OF THE SPACE INCLUDING BUT NOT LIMITED TO UTILITY COMPANY DIRECTIONS, SERVICE AND/OR TAPPING FEES LOCAL, COUNTY, OR STATE SERVICE CHARGES, INSPECTION CHANCES Alm PERMIT FEES, LANDLORD'S CONNECTION FEES, LANDLORD'S UTILITY CHARGES, LANDLORD' S METERING CHARGES AND /ON LANDLORD'S EQUIPMENT CHARGES M WHERE THE TENANT ELECTS TO RE -USE, AND THE LANDLORD HAS APPROVED THE RE -USE IP RENOVATION OF AN .EXISTING HVAC AND /OR PLUMBING SYSTEM, REPAIR OR REPLACE ALL IR PART OF THE HVAC AND/OR PLUMBING EQUIPMENT TO ENSURE PROPER AND EFFICIENT OPERATION OF THE SYSTEMS), ENSURE THE HVAC SYSTEM IS CAPABLE OF MAINTAINI. THE SPACE TEMPERAMRES WITHIN THE LEASED PREMISES IN ACCONWCE WITH THE LANDLORD'S LOCAL, STATE, AND FEDERAL REQUIREMENTS, MB PROVIDE WRITTEN CONFIRMATION'TO LANDLORD OF ALL WARRANTIES' IMPLIED. • TENANT ELECTS NOT TO RE-USE EXISTING RU E OR BRB NT, CONDUIT, PIPIT& FIXTURES INCLUDING BUT T LIMITED TO AN MY ROOF MOUNTED EQUIPMENT, TENANT MALL AT TENANT'S EXPENSE REMOVE. SUCH PARTS OF THE SYSTEM AND EQUIPMENT NOT BEING RE -USED INCLUDING CURBS AND UTILITY SERVICES TO SUCH EQUIPMENT, CAP ALL PIPING AT LANDLORD MAINS. TENANT SHALL PERFORM ALL NECESSARY REPAIRS TO THE ROD'ING SYSTEM AND/OR ADJACENT CONSTRUCTION IN ACCORDANCE WITH THE LANDLORD'S CRITERIA AND DETAILS INDICATED DN LANDLORD'S MECHANICAL DETAILS AND SPECIFICATIONS DRAWINGS. II. PLUMBING DEFICIENCIES MD NON- CBMNIING ITEMS - IF AT ANT TIME TARING THE TERM OF THE LEASE, LANDLORD DETERMINES TENANT'S EQUIPMENT OR SYSTEM WAS NUT. BEEN INSTALLED ER IS NOT OPERATING IN ACCORMICE WITH MA: 4ACTLRER' S RECOMMENDATIONS OR LANDLORD'S REQUIREMENTS, UNDLORD MAY, IN ADDITION TO ANY OTHER RIGHTS AND REMEDIES IT MAY HAVE, AFTER GIVING FIVE 45) DAYS WRITTEN NOTICE TO TENANT OF ITS INTENTION TO DO S0, CORRECT SUCH DEFICIENCIES AS LANDLORD MAY ELECT TO PERFORM FOR AND ON TENANT'S BEHALF. TENANT SHALL REIMBURSE LANDLORD FOR ALL COSTS INCURRED BY LANDLORD FIR THE CORRECTION OF THE DEFICIENCIES PLUS A FIFTEEN PERCENT 415. ADMINISTRATIVE CHARGE. THE TOTAL AMOUNT SHALL BE WE AND PAYABLE TO LANDLORD UPON DEMAND. P. FOR INSTALLATION OF EQUIPMENT, CONTRACTOR SHALL ONE. TO LANDLORD'S DETAIL DRAWINGS AND MECHANICAL DETAIL AND SPECIFICATIONS DRAWINGS A PLUMBING SERVICES HAVE BEEN PROVIDED FOR TENANT'S USE. TENANT SHALL EXTEND SERVICES PER TENANT'S AND LANDLORD'S REQUIREMENTS SEE LANDLORD'S BUILDING DRAWINGS FOR LOCATION. THE LANDLORD HAS PROVIDED A DOMESTIC WATER, SANITARY VENT AND SANITARY SERVICE. THE TENANT SHALL CONFECT TO THE SERVICES (MANDATORY) TENANT SHAD. EXTEND SERVICE PER LANDLORD REQUIREMENTS B. NO PIPING SHALL BE INSTALLED IN DEMISING WALL C A HANDICAPPED ACCESSIBLE TOILET ROOM IS REQUIRED IN EACH TENANT SPACE, EXCEPT FOOD COURT AND Q AREA TENANTS. Q AREA TENANTS MO ELECT AND ALL NON- FOODCOURT TENANTS WHERE SAME DIES NOT EXIST. FURNISH AND INSTALL A MINIMUM OF ONE WATER CLOSET, ONE LAVATORY, OM FLOOR DRAIN, OHE 6 -GALLON WATER HEATER, AND ALL OTHER REQUIRED. MATERIAL AND EQUIPMENT FORA COMPLETE TOILET ROOM. TOILET ROOMS SHALL BE AS REWIRED BY APPLICABLE CONES AND ADA MATERIALS I. ALL MATERIALS SHALL BE NEW. USED MATERIAL SHALL NOT BE PERMITTED. 2. GAS PIPING SCHEDULE 40 BLACK STEEL PIPE V1TH MALLEABLE SCREWED FITTIT&S INSTALLED PER LANDLORD'S, STATE AND '�4L AUTHORITIES', AND THE UTILITY COMPANY REQUIREMENTS. GAS COCKS 2' MD SMALLER SHALL BE SCREWED IR. PLUG VALVE 2T& PSI, 2 -1/2' MD LARGER SHALL BE IRON FLANGED, PLUG VALVE, 200 PSI. b. PAINT ALL GAS PIPING EXTERIOR TO THE BUILDING, WHICH VAS INSTALLED UNDER THIS CONTRACT, WITH TYO COATS OF DARK BROWN RUST RESISTANT PAINT. PIPE SHALL BE CLEANED PRIOR TO PAINTING F GAS PIPING ON ROOF SHALL BE INSTALLED AND SUPPORTED PER DETAILS d THERE SHALL BE ND VALVES OR UNIONS INSTALLED IN RETURN AIR PLENUMS. 3. DRIED UNDERGROUND AND BELOW MOOR SEVER AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON PIPE WITH APPROVED COMPRESSION JOINTS. UNDERGROUND SEVER PIPING SHALL BE A MINIMUM SIZE OF 2', MINIMUM OF 1/8' PER FOOT OF SLOPE. NO- N. JOINTS ARE NOT PERMITTED. 3a. UNDERGROUND SEVER PIPING AND FITTINGS HAY BE PVC -DON ASIA- 112665-78 SCHEDULE 40 WITH SOLVENT WELDED JOINTS. UNDERGROUND SEVER PIPING SHALL BE A MINIMUM SIZE OF 2', MINIMUM OF 1/8' PER FOOT OF SLOPE Z±\ ABOVE GROUND, ABOVE OR BELOW FLOOR, SEWER AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON PIPE WITH NO HUB JOINTS PVC AND ABS PIPING ARE NOT PERMITTED. 5. UNDERGROND AND BELOW FLOOR FOOT AND CAD WATER PIPING SHALL BE TYPE 'K' COPPER PIPE OR TUBING WITH SIL -COS 15 SILVER BRAZED JOINTS. ABOVE FL. HOT AND COLD LATER PIPING SHALL BE TYPE 'L' COPPER PIPE WITH 95 -5. SOLDERED JOINTS OR SIL -COS 15 SILVER BRAZED JOINTS.. INSULATE ALL ABOVE GROUND, ABOVE OR BELOW FLOOR, HUT AND COLD WATER PIPING WITH A MINIMUM OF 1'. THICK FIBERGLASS PIPE INSULATION WITH A VAPOR BARRIER AND PLENUM RATED PRE -MOLDED FITTING CIDERS'Ot 1' THICK CLOSED CELL PLENUM RATED • INSULATION INSULATE ALL SANITARY LINES SERVING TENANT SPACE WHEN REQUIRED TO PREVENT CONDENSATION RESULTING FROM TENANT'S OPERATION. ALL JOINTS SHALL DE INSULATED AND SEALED WITH VAPOR BARRIER CEMENT. ALL INSULATION; VAPOR BARRIERS, PRE -MOLDED FITTING COVERS, ETC. SHALL HAVE SURFACE BURNING CHARACTERISTICS NOT EXCEEDING A FLAME SPREAD RATING OF 25 AND A SMOKE DEVELOPED RATING OF 50. 8. FURNISH AND INSTALL DIELECTRIC UNIONS FOR DISSIMILAR PIPING MATERIALS, ALL BACKFLBN PREVENT., VALVES, UNIONS. BYPASS PIPING AND TESTING AS REWIRED BY THE FIXTURE MANUFACTURER, BY THE LOCAL UTILITY AND CODES. PROVIDE ACCEPTABLE SUPPORTING DEVICES FOR ALL PIPING. ALLOY FOR PIPE EXPANSION AND PREVENTION OF ELECTROLYSIS. E G. 10. GAS METER III. FIRE SUPPRESSION SYSTEMS a. GAS NETER - PHASE 1 - NOT APPLICABLE GAS METER - •GS' - PHASE II - FOOD COURT WHERE GAS IS REWIRED BY TENANT'S APPROVED DESIGN, INSTALL AT NO EXPENSE TO LANDLORD, A GAS METER COMPLETE WITH REGULATORCS), SHUT OFF VALVES, UNIONS AND ALL OTHER ACCESSORIES PER LOCAL UTILITY COMPANY. LOCATE METER AS DIRECTED BY LANDLORD AND UTILITY. 11. ALL FOOD TENANTS AND ANY HIGH HAZARD TENANT SHALL FURNISH AND INSTALL A REDUCED PRESSURE BACKFLOW PREVENTER. IF WHERE REWIRED BY LAICAL AUTHORITIES AND UTILITIES ALL TENANTS SWUM INSTALL BACKFLOV PREVENTION. CONNECT TU LANDLORD'S SANITARY AND MU) WATER PIPING AT LANDLORD'S POINT IF BERVIGF CORECTIO PHASE I MB FLIED COURT TENANTS SFRALL CONNECT TO LANDLORD SUPPLIED SANITARY VENT SYSTEM WERE MITI.. POINT.) OR INCREASED SIZE OF SERVICE IS REQUIRED (AND APPROVED BY LANDLORD) EMPLOY CRITERIA NT LANDLORD'S CONTRACTOR TO PERFORM THE WORK PER THE LANDLORD'S CRITERIA AT NO EXPENSE TO LANDLORD, SEE PLAN FOR LOCATION ALL TENANT WORK PERFORMED ABOVE THE CEILING OF OTHER TENANTS SHALL BE COORDINATED VIER OTHER TENANT.) AND LANDLORD AIR CHAMBERS ARE REQUIRED ON EACH HOT AND COLD WATER SUPPLY TO EACH PLUMBING FIXTURE OR PROVIDE SYSTEM SHOCK ABSORBERS SIMILAR TO J. R. SMITH 'HYDROTROL' SERIES 5000 SIZE AS REQUIRED BY TENANT PLUMBING SYSTEM. H PLUMBING FIXTURES - THE FOLLOWING IS A MINIMUM SPECIFICATION FOR FI %TIRES' I. INTERCEPTORS a. GREASE INTERCEPTOR SHAT BE INSTALLED WERE REQUIRED BY STATE AND LOCAL CODES AND LANDLORD'S REQUIREMENTS TO RECEIVE GREASE LADEN WASTE TENANTS SUBMITTAL DRAVING3 SHALL STATE INTERCEPTOR FLOW CAPACITY IN G P.M. AND PONDS OF 8EASE STORAGE. FLGV CAPACITY ND A PONDS IF GREASE STORAGE SHALL BE CALCULATED PER THE GREASE TRAP MANIE.TUREPS GUIDELINES. CONT- RACTOR SHALL VENT ALL FIXTURES DRAINING Tf7 GREASE TRAPS AND THE GREASE TRAP. 8. GREASE INTERCEPTOR SHALL BE CAST IRON J.R. SMITH 8000 SERIES, COMPLETE WITH FLOW CONTROL INSTALL IN LOCATION AND METHOD APPROVED BY LANDLORD AND THE LOCAL PLUMDING AND HEALTH DEPARTMENT CODES. WORK SINKS FOR HAIR SALONS, PET SHOPS, AND EYEGLASS 5BORATORIES. INTERCEPTORS SHALL BE EQUAL TO J. R SMITH 8700 SERIES. 2. FOOD PREPARATION PLUMBING FIXTURES SHALL BE STAINLESS STEEL AND SHALL BE FURNISHED, INSTALLED MB CONSTRUCTED TO CONFORM TO ALL CODES, HEALTH. DEPARTMENT, AND NATIONAL SANITATION FOUNDATION WATER CLOSET - AMERICAN STANDARD 2108.408 CADET WITH CHROME SUPPLY AND STEP VALVE, AND OPEN FRONT WHITE SEAT AND SEAT COVER. SET AT ADA HEIGHT. 4. LAVATORY - AMERICAN STANDARD 9140.011 WHEEL CHAIR LAVATORY 27 X 20' WITH WALL WIRERS, CFRE E SUPPLIES AND STOPS, AND 1-1/2' OR<O. TRAP WITH CLEAMXIT. FURNISH WITH CENTER SET FAUCET, SELF CLOSING WITH FLOW REGZILATIOI, AMERICAN STANDARD OR EQUAL, CHRI E PLATED WITH 7723.018 GRID DRAIN/OFFSET TAIL PIECE. 5. WATER HEATER (MIRINO. - A 0. SMITH - G GALLON, 1500 WATTS INSULATED PER ENERGY CODE. TOP VALVE SHALL BE PIPED FULL SIZE AND SAFEW/STED TO A DRAIN PAN OR FLOOR DRAIN HEATER SHALL HAVE A 5 -YEAR WARRANTY. 6. WATER HEATERS SHALL CONFORM TO ALL ENERGY CODES AND SHALL INCORPORATE A 2 -GALLON THERMAL EXPANSION TANK. HEATER SHALL BE ELECTRIC OR GAS FIRED AND SHALL INDRPORATE A TEMPERATURE- PRESSURE RELIEF VALVE PIPED TO A FLOOR DRAIN. 7. WHERE WATER HEATERS ARE INSTALLED ABOVE THE FINISHED CEILING, INSTALL HEATERS IN A 3' DEEP WATER TIGHT PAN WITH RELIEF VALVE PIPED TO PAN AND PAN SAFE WASTED TO AN APPROVED FLOOR DRAIN. GAS FIRED WATER HEATERS SHALL NOT BE INSTALLED IN CONCEALED SPACES AND SHALL BE LOCATED IN A SEPARATE ROOM. PROVIDE COMBUSTION AIR FOR GAS FIRED WATER HEATERS WITHIN A ZERO TO POSITIVE PRESSURE ENVIRONMENT. INSTANTANEOUS UNDERSINK TYPE WATER HEATERS ARE ALSO ACCEPTABLE. 0 HAND SINKS, FAUCETS AND SPECIALTIES SHALL BE FURNISHED AND INSTALLED PER HEALTH DEPARTMENT REQUIREMENTS AND ALL APPLICABLE CODES 9. FLOOR DRAIN - J. R SMITH FIGURE 2010 - RIM A NICKEL BRONZE OR SATIN BRONZE FINISH WITH PRIMER TAPPING WHEN REQUIRED. FLOOR BRAINS SERVING ALL SODA DISPENSER WASTE LINES SHALL BE PROVIDED WITH TRAP PRIMERS 30 CLEAT/OUTS - U R SMITH 4000 SERIES WITH NICKEL BRONZE OR SATIN BRONZE FINISH TOP AND TAPER THREAD BRONZE PLUG OF SIZES SHOWN . PLANS. ALL CLENIUTS SHALL BE INSTALLED IN FINISHED FLMR OR ABOVE. CLENCUTS UNDER SLAB ARE NOT ACCEPTABLE. 11. TRAP SEAL PRIMER VALVE - J. R. SMITH FIGURE 2699. 12 WATER METER a. PHASE I, Q AND FOOD COURT - INSTALL AT NO EXPENSE TO LANDLORD, A RATER METER IN AN APPROVED LwATiiYN PER THE LOCAL WATER TILITY COMPANY AND LANDLORD'S REQUIREMENTS ONTR CRACTOR SHALL PAY ALL FEES AND LANDLORD CHARGES ASSOCIATED WITH METER AND METER INSTALLATION PHASE II - WATER SUB-METER 1S REQUIRED ONLY BY LARGE WATER CONSUMING TENANTS WATER METER TO BE INSTALLED BY TENANT COMPLETE WITH UNIONS AND SERVICE VALVES TENANT TO PURCHASE AND INSTALL BADGER MODEL SC -ER 01. APPROVED EQUAL DIGITAL READ OUT IN CU FT. LOCATE METER 4' -6' AFF !N AREADILY ACCESSIBLE LOCATION. A TENANT'S SPRINKLER SYSTEM SHALL BE INSTALLED FROM LANDLORD'S SPRINKLER BULK MAIN SERVICE PROVIDED BY LANDLORD FOR THE PREMISES IN TEE EVENT A SPRINKLER SYSTEM EXISTS, MODIFY THE EXISTING SYSTEM. IN THE EVENT TENANT REQUIRES LARGER SPRINKLER SERVICE, TENANTS CONTRACTOR SHALL EMPLOY LANDLORD'S CONTRACTOR TO INSTALL INCREASED SIZE OF SERVICE PER LANDLORD REQUIREMENTS THERE SHALL BE ONLY ONE CONNECTION PER TENANT. THERE SHALL DE NO CROSS FEEDS TO OTHER TENANTS OR MALL SYSTEMS D PROVIDE A SPRIKKLER SYSTEM FOR TEE ENTIRE PREMISES INCLUDING ALL PIPING AND ACCESSORIES PER THE REQUIREMENTS OF ALL APPLICABLE CODES, FACTORY MUTUAL, NFPA -13, LANDLORD AND LANDLORD'S FIRE AND CASUALTY INSURER C ALL PIPING SHALL BE HYDRAULICALLY DESIGNED AND INSTALLED PER NFPA -13 ORDINARY HAZARD, CLASSIFICATION GROUP II. HYDRALIC CRITERIA FOR SYSTEM DESIGN SHALL BE DENSITY - 0. 18 GPM PER SO FT. - FIRE AREA - MOST REMOTE 25000 SO. FT. WITH A 500 GPM HOSE ALLOWANCE OBTAIN FLOW AND PRESSURE FROM LOCAL AUTHORITIES OR LANDLORD'S INSURANCE UNDERWRITER. PIPING SHALL BE PER MPA, DR IF MORE STRINGENT FM APPROVED. D MAXIMUM SPACING OF SPRINKLER HEADS SHALL BE 130 SE E7. PER HEAD IN SALES AREA AND 100 SOFT. PER HEAD IN STORAGE AREAS OR HIGH HAZARD AREAS SPRIKKLER HEADS IN THE SALES AREA SHALL BE CONCEALED /FLUSH OR SEMI-R PENDANT WITH AN ESCUTCHEON SPRINKLER HEADS IN STOCK OM RO SHALL HALL BE BE RECESSED OR UPRIGHT, BRASS ON CHROME. SPRIKKLER HEADS IN CONTROL AREA (STOREFRONT PDP -OUT) SHALL DE CONCEALED /FLUSH TYPE, FACTORY PAINTED TO HATCH CEILING COLOR. TEMPERATURE RATINGS SHALL BE AS MOUIRED BY LANDLORD'S FIRE AND CASUALTY INSURER AND /OR AUTHORITY HAVING JURISDICTION. ALL SPRINKLER' HEADS MUST BE UNDERWRITER'S LABORATORIES LISTED AND FACTORY MUTUAL APPROVED. 4 Q F. CONTRACTOR SHALL OBTAIN FROM LANDLORD THE LANDLORD'S FIRE AND CASUALTY INSURERS NAM, ADDRESS, AND PROJECT INDEX NUMBER. PRIOR TO INSTALLATION, CONTRACTOR SWILL SUBMIT. SEVEN (7) SETS OF CALCULATIONS AND SEVEN (7) SETS IF PRINTS OF SPRINKLER DESIGN TO LANDLORD'S FIRE AND CASUALTY INSURER FOR APPROVAL UPON APPROVAL AND PRIOR TO INSTALLATION, CONTRACTOR SHALL FORWARD ONE CI) REPRODUCIBLE SEPIA OF THE APPROVED DESIGN AND TWO L. BLUE LINE PRINTS, WHICH SHALL HAVE THE LANDLORD'S INSURER'S APPROVAL STAMP, TO THE LANDLORD FOR LANDLORDS APPROVAL AND RECORDS.- CONTRACTOR TO OBTAIN ALL OTHER APPROVALS FROM APPLICABLE AUTHORITIES AND SUBMIT APPROVED PRINTS TO LANDLORD FOR .NDLORD' S RECORDS. IV. HVAC D. G & REIMBURSE LANDLORD FOR ALL COSTS OF DRAINING MD REFILLING LANDLORD'S SPRINKLER SYSTEM WHERE SAME IS REWIRED 70 COPLETE TENANT'S SPRINKLER SYSTEM. H ALL OTHER CODE ER LAMDTDD REQUIRED FIRE PREVENTION SYSTEMS AND ACCESSORIES SHALL BE INCQiA:RATED AS PART (E" THIS' SCOPE. OF VOAC. TENANT'S SPRINKLER PIPIT& 4' AND LARGER SH .L BE INSTALLED WITH HANGERS AT EVERY BAR JOIST LASH INSTALLED PERPElDSICI AR TO DAR JOISTS, AND WITH HANGERS SUPPORTED FROM TAI DAR. JOISTS EVERY 10'-0' ON CENTERS WHEN INSTALLED PARALLEL TO OAR JOISTS 4 ALL HANGERS AND /OR SUPPORTS SHALL BE INSTALLED WITHIN 6' IF A .JOIST PANEL POINT.. THE MALL MANAGEMENT, THE LANDLORD'S FIRE AND CASUALTY INSURER,. AND THE LOCAL FIRE DEPARTMENT MUST BE MTIFIED AT LEAST 48 HOURS PRIER TO MAKING ANY MODIFICATIOS TO THE EXISTIT& FIRE PROTECTION SYSTEM.). WORK:SINLL DE COORDINATED SD THAT ABLY OE CI) RISER IR BLUCMAIN IS SHUT -QUERN FOR ANY GIVEN TIME. SPRINKLER SYSTEMS). SERVICE SHALL': BE RESTORED TO THE AREAS AFFECTED AT TEE ETD OF EACH WOKING DAY DURING INC . CONSTRUCTION. PERIOD PIPING TEST - ALL ABOVE GRADE PIPING INSTALLED BY THIS. CONTRACT. SHALL BE. TESTED AT A PRESSURE' OF 200 LBS. HYDROSTATIC FOR TWO C. TORS AND NI. NOTICEABLE LEAKS TO BE REPAIRED INTEL TIGHT TEST SHALL BE WITNESSED BY THE OVER' S REPRESENTATIVE AND WRITTEN CERTIFICATION OF SUCCESSFUL TESTING SHALL BE SUBMITTED TO INC ENGINEER PRIOR TO FINAL ACCEPTANCE. THIS CONTRACTOR SHALL ALSO BE REQUIRED TO PERFORM ALL OTHER TESTS REQUIRED BY THE PREVIDS SPECIFIED AGENCY HAVING AUTHORITY. EXHAUST )FADS WHERE REWIRED BY CODES AND/OR LANO.OUYS PROPERTY AND CASUALTY INSURER'S), MALL IMIRA RATE AM APPROVED AUIDMATIC FIRE SUPPRESSION SYSTEMS) COMPLETE VIM FAN INTERLOCK, NNOIAT. GAS APPLIANCE SNOT -OFF SOLENOID VALVE, ELECTRICAL INTERLOCKCSANT TRIPS), MANUAL RELEASES, ETC., PER APPLICABLE CODES, NFPA,ANO/OR LANDLORD'S FIRE AND CASUALTY INSURER.). H TOY STORES AND ORIR STORES THAT HAVE .HIGH PILED STORAGE OF PLASTIC MATERIAL AS DETERMINED BY THE LOCAL FIRE MARSHAL AND/OR LANDLORD' FIRE AND CASUALTY INSURER SHALL BE DESIGED FOR ..3 EPEE PER S0. FT. OVER THE MOST REMOTE 3000 50 FT. VERIFY REQUIREMENTS. TENANT HVAC SYSTEM CRITERIA 1. TENANT SHALL DESIGN, FURNISH AND INSTALL A COMPLETE HVAC SYSTEM TO HEAT AND COD. THE ENTIRE PREMISES IN STRICT COFOUNAME WITH THE CRITERIA AND DESCRIPTOR CONTAINED IN LANDLORD'S. MECHANICAL DETAIL AND SPECIFICATION BRAVING. THE LEASE AND/OR TENANT MAN.L T 2. THE HEATING AND COOLING SYSTEM DESIGN SHALL BE BUSED ON THE APPLICAEE STATE AND LOCAL COMA AND THE MFORBATION PROVIDED ID THE ATTACHED CALCULATION EOM, WHICH IS DERIVED FROM TIE MOST RECENT DESIGN CONDITIONS LISTED IN TIE AMERICAN SOCIETY OF EEARM, REFRIGERATE. AND AIR- CONDITIONING ENGINEERS, (A SM. FE A E I MANUAL HEAT .IN CALCULATORS 'SHALL DE RASED UPON THE NINTH, DAY ;AM HOUR OF PEAK SOLAR, RENAL AND INTERNAL HEAT GADNS USING CODE REWIRED MINIMUM OUTSIDE AIR 'DUR RETT. AT DESIGN CONDITIONS 4. HEAT LOSS CALCULATIONS SHALL BE BASED UPON THE FULL SEAT LASS AND COE REQUIRED MINIMUM OUTSIDE AIR REQUIREMENTS AT DESIGN CONDITIONS (CREDIT SHALL NOT BE TAKEN FOR INTERNAL HEAT WINS, S TIE FOLLOWING SHALL . APPLICABLE TO THE CALCIAATIOS FOR SPECIAL OCCUPANCIES (E.G., BEAUTY SALONS, PET SEAS, BABA SHOPS, GAM OR AMUSEMENT FACILITIES, ROIOFINISHING ESTABLISHMENTS, RESTAURANTS, ETC ), _ . a CODE REQUIRED OCCUPANCY LEVEL b. CODE REQUIRED OUTSIDE AIR MERITS.. c. ALL HEAT PRODUCING GAS OR ELECTRIC APPLIANCE LOBS WITH LANDLORD APP.. DIVERSITY FACTORS. d. LANDLORD MAKE -UP AIR REQUIREMENTS ALL MAKEUP AIR EU. BE CONDITIONED. 6 FOOD TYPE OR OTHER ODOR PRIDED. TENANT'S NYAC SYSTEM SHALL MAINTAIN A SLIGHT NEGATIVE PRESSURE DIFFERENT. BETWEEN THE PREMISES AND THE ENCLOSED MALL Ate EITHER COVEN AREAS OF THE SIPPING CENTER. 7. NON -ODOR PRODUCT.. TENANT'S HY. SYSTEM SHALL MAINTAIN A SLIGHT POSITIVE PRESSURE DIFFERENTIAL BEDI.N TIE NOOKS AND THE ENCLOSED PALL AND OTHER CON ON AREAS OF THE S.M. CENTER • UNLESS OTHERWISE PERMITTED BY LANDLORD, DNS. AIR, MELEE AIR, EXHAUST AIR GR ANT OTHER TYPE OF OPENING OR GRILLE SHALL NOT BE PERMITTED IN DR ON ANY 11.1SING PARTITION, SERVICE CORRIDOR WALL ON EXTERIOR VALE OF THE PREMISES ON EXTERIOR WALL OF THE SOPPING CENTER 9. TENANT HVAC SYSTEM a PHASE ti, Q AND FOOD OGRE - ISERE A HVAC INI . IS TO BE REPLACED W, Af3E A MEV INSTALLATION IS REQUIRED BY TENANTS, THE HVAC SYSTEM SHALL. BE R NNISHED AND INSTALLED [INSISTING IF A GAS OR ELECTRIC HEATING/ELECTRIC COLING ROFHP l:N1T(S) TO SERVE TIE ENTIRE PREMISES EQUIPMENT SWILL BE EQUAL TO CARRIER, TRAM, OR YORK. .PHASE II TEMARTS SHALL CORRECT TO LANDLORD'S TOILET EXHAUST DOT. b. PHASE I - TENANTS SHALL INSTALL A SPLIT SYSTEM AIR O NDITIDER,. WITH ELECTRIC DUCT FEAT, LOCATED IN AREAS DESIGNATED ON LANDLRD' BRAVING. TFE WIT MALL BE CONNECTED TO THE LANDLORD'S MINIMM OUTLIER AIR DUCT WHERE PROVIDED THE AIR HANDLING WIT SHALL BE MODULAR, FACTORY ASSEMBLE DRAT/ EMU AND SUPPORTED FRIER STRUCTURE ONLY IN AREAS APPROVED BY LADLORD AND PER LANDLORD DETAILS THE CryDEN.R. WIT SHALL . ROLF HUNTED AND SUPPORTED BY CURB AT LANDLORD'S DESIGNATED LOCATION REFRIGERANT PIPING SHALL . ROUTED THROUGH LAND.DRD DESIGNATED CHASES AND DOCUMENTED IN DESIGN CRAVINGS CENDOCATE SHALL BE RUN TOLL. PROVIDE CONDENSATE DRAIN INC[RRIDTR, MEN PROVIDED. OR TO TENANTS SANITARY SEVERE OR PUMPED TOLL APPROVED SEVR TENANT SHALL RITE AS APPROVED BY L L B. PHASE I - FOOD QUIRT - FOOD TENANTS AND Obi PRODUCING TENANTS - LOV AMBIENT CONTROL OF MECHANICAL COOLING DOWN TO 0 DECREES F. AMBIENT TEMPERATURE IS REQUIRED ON ALL FOOD, FOOD COURT OR ODOR PRODUCING TENANT ROOFTOP HVAC SYSTEMS AND ALL PHASE I SPLIT SYSTEMS PDVERED EXHAUST IS REQUIRED FOR FOOD. AND ODOR PRODUCING TENANTS PHASE II - NON FOOD TENANTS - LOW AMBIENT CONTROL OR ECONOMIZER CYCLE IS REQUIRED ON ALL PHASE II NON ODOR PRODUCING TENANTS IF AN ECONOMIZER CYCLE IS INCORPORATED, THE HVAC SYSTEM SHALL INCORPORATE A GRAVITY OR INTEGRAL POWERED RELIEF IN THE ROOFTOP UNIT. PHASE II, G2 AND FOOD COURT - SUPPORT. RTUs ON FULL PERIMETER CURB AS SUPPLIED BY THE UNIT MANUFACTURER ONLY IN AREAS STRUCTURALLY AND AESTHETICALLY. APPROVED. BY LANDLORD. DETAILS C -5 X 6.7 LBS/FT STRUCTURAL STEEL CHANNEL SUPPORTS TO SPAN JOISTS UNDER RTU CUM ALL TENANT ROOF EQUIPMENT SHALL BE LOCATED AT A MINIMA .F FIFTEEN 1151 FEET FRON ANY MALL EQUIPMENT. AND FRI14 ANY OTHER TENANT'S ROOF EQUIPMENT. NOTIFY LANDLORD'S ENGINEER OF ANY CONFLICTS OBTAIN LANDLORD FIELD REPRESENTATIVE'S WRITTEN APPROVAL BEFORE CUTTING ROOF. GOOSENECKS SHALL . NOT BE INSTALLED'. UNLESS SPECIFICALLY APPROVED BY LANDLORD. TEMPORARY RORK PLATFORM (MIN. 4' -0' WIDE) IS REQUIRED CONSISTING OF PLYWOOD COMPLETELY SiRROUNDING THE ROBFT. UNIT.) AND EITHER EQUIPMENT OR DUCTS THROUGH THE ROOF. THE ENTIRE MOMING AREA SHALL REMAIN ON ROOF DURING TIE ENTIRE PERIOD OF INSTALLATION AND NI. BE REMOVED FROM INC ROOF AND THE SHOPPING CENTER SITE UP. COMPLETION OF TM INSTALLATION. BY CONTRACTOR... H ALL ROOF MOUNTED FANS, TOILET EXHAUSTERS, AND MISCELLANEOUS EQUIPMENT SHALL BE OF ALUMINUM CONSTRUCTION, WITH. FABRICATED ROT CURBS AS DETAILED ON LANDLORD'S TYPICAL TENANT'S MECHANICAL DETAILS AND SPECIFICATIONS DRAWINGS. ROUTE ELECTRIC POWER AND CONTROL WIRING TWIN. A SEPARATE ROOF PENETRATION FOR EACH OF THE CONDUITS .PUSH PENET J TION E'ER LANDLORD DETAILS. DO NOT ROUTE POWER CONDUIT THROUGH .nLF CURB WALL 'W NOT DRILL HOLES IN CONDENSATE PAN OR CONPRESSOR/CWOENSER SECTION FUR. ALL 8 TE SIFP F MOUNTED EQUIPMENT Se. BE .IDENTIFIED WITH A IANCURD SIPFLIED LABEL. THE TENANT SMALL CONTACT TIE NALL MANAGEMENT FIR THE NECESSARY LABEL IF THE LANDLORD' 5 LABEL IS NOT AVAILABLE THE RUT TIP EQUIPMENT SHALL BE MARKED WITH THE TENANT'S MINE AMO UNIT WADER WITH A MINIMUM OF I -1/2• STENCILED LETTERS. K FRNE ALL SIDES IF RI F PENETRATIONS, IF ONE SIDE OF PENETRATION IS GREATER TINA 12 IN[IES. WITH 3' X 3' X 1/4' ANGLE TO SUPPORT THE METH. DECK ANVs SHALL BE CLAMPED OR WELDED TO THE STRUCTURAL STEEL NESTS. BENTS, OR &TRIERS AND SHALL BE INSTALLED TIGHT TO THE BITE. OF TIE REF DECK INSTALLATION SHALL BE AS APPROVED BY THE , ALDO IQB DIE NOT DRILL JOISTS ROOF MONIED EAERENT PROJECTIONS TRIBE OF TENANT'S HVAC EMINENT IR MY OSIER TENANT ROOF MOUNTED CONSTRUCTION SHALL BE VISIBLE ABOVE TIE RIERIOR IYALL PARAPET. UNLESS OTHERWISE KNITTED BY LNGEM. IF PERMITTED, TENANT. SMALL, AT TENANT'S EXPENSE, PAINT ALL SUCH HVAC EMINENT OR REIF MOUNTED CBNST,R(XTIIN AND /OR RAVIBE .RED4ING FOR SAFE AS MAY BE REWIRED BY LANDLORD DIFFUSERS, MELEES, AND REGISDFS SHALL HE STEEL IR ALUMINUM AS NAMFACIIRED BY TITUS, BALDER -COUV. CANNES, OR OTTER APPROVED DITH OUPOI,ED 11LADE DAMPERS. : RETURN AIR BETWEEN STOCK AND SALES AREA SA LL MIT RELY UPON MY ACCESS WAY (000R11AY5. VINDOV OPENINGS. EEG) BETWEEN STD. RID SATES AREAS` AIR DANCE Ali EMIPNE1/T, INCLUDING ROOFTOP WITS, DIFFUSERS, REGISTERS. NL GRI!]ES TO THE AIR QUANTITIES INDICATED ON THE PLANS OR ON NE SCHEDULE TO WITHIN 10X IF VANES FLEXITLE COBE'CEOS WI.. AGE CODE APPROVED ARE REQUIRED ON ALL ACTIUM COINFLTIDWS TO AIR NWVING EQUIPMENT INCLUDING ROOFTOP AIR HNOILIIM WITCS), AND NAST. FIRE DAMPERS ARE REQUIRED TO BE INSTALLED IN ANY OPENING IN ANY PARTITION 1DFIE TEE OPENIT& OCCURS BELOW THE LEVEL OF THE SPRIKKLER PROTECTI. D4 IRE SIDE OF TEE PARTITION AND ABOVE THE SPRINKLER PROTECTION IN TIE MM. SIDE OF TIE PARTITION, AND PENETRATIONS OF FIRE RATED CONSTRICTION PER CODE. FIRE DAMPERS SHALL BE U L. LTSTEB N® INSTALLED PER . 8 1 4 08 OTT Ci1RERS R 11 8IETNT. FIRE DAIFERCS) SITY.L W AWN, AIR BALANCE, OR ER LANDLORD APPROVED. ALL TEIN-FIAREBACIARL FITTINGS, HANGERS, FABRICATIONS. ISENIATIOS, MATERIALS AND NEIHODS SHALL BE GALVANIZED SHEET META_ FATICATED 5 INSTNIED. IN STRICT ACCORDANCE WITH THE LATEST EDITED OF DAR.. , WP, ALL CODES TMD AS DETAILED ON DRAWINGS MISS OTHERWISE NamED, SUPPLY, RETIRE AND EXHAUST DUCTWORK SHALL BE CONSTRICT. IN RLFIIDWICE WITH TEE I' K. G POSITIVE/NEGATIVE PREmoc TARE ALL DUCTWORK SHALL BE INSTALLED AS HIGH AS POSSIBLE- RHO. APPROVED FOR INSTALLATION BY THE LANDLWD, FIBERGLASS NE PA= = SAN_ RE I -D? IVORSACGWIRG TYPE 700 FRK INSTALLED PER THE MNNFAMIER•S TRIO S.C.. REQUIRDENTS FOR SUPPLY AND RETURN AIR REI ERN. NMATE ALL SUPPLY AIR, OUTSIDE AIR. AND COUMUSTION AIR DUCTWORK VIM 1 -I/2' MI. EXTERIOR FIBERGLASS DUCT INSLATION WITH VAPOR HARRIED PER M5OFACI118ERS REQUIREMENTS AND RECOMMENDATIONS. IF ATE EONS ON ANY MALL BE TENANT SURFACE, INSULATE AS REMIND TD ELIMIRA. THE CONDENSATION. FLEXIBLE DellAF. SMALL OILY DE PERMITTED TO BE INSTALLED FOR THE FOAL VERTICAL GMECTIEN TO DIFFUSERS THE MAXIMUM LENGTH OF FLEXIBLE DIET SHALL BE LIMITED TO 5'-0' FOR ANY ONE DIFFUSER CONECROO FLEXIBLE DUCT MATERIAL SHALL HAVE A FUME SPREAD LESS MIN 25 AND A SHOE DEVELOPED RATING LESS THAN 50. SECURE BOTH ENDS MTH APPROVED F4EMN MATERIAL BELTED RERUN AIR SYSTEMS SEAL ONLY DE INSTALLED WHEN REQUIRED OR APPROVED BY MANm(vR WHEN A DUCTED RETURN .AIR SYSTEM IS REQUIRED CON PEINNITTOD BY LANDLORD, FURNISH AND INSTALL RELIEF GRILLES IN CEILING TO REPENT MEM . RELIEF GRILLES SHALL BE SIZED AT 1 Sm FT. PER 330 SQ. FT. LEASABLE s AEA DUCTED HETURN AIR SYSTEM GRRILLES SOUL BE SIZED FIR A MAXIMUM OF 500 F. P.M. VELOCITY. • SEAL ACT PETETRATIIIS AT SEMISING VALLS WITH MATERIAL APPROVED BY APPLICABLE CODE AIDERITIES IL TENANTS MIQL IN TEE SIDE [PINION OF THE LANDLORD, PRODX.E ODOR SHILL PROVIDE AN EXHAUST SYSTEM NEVER OTHER SYSTEMS. WHICH WILL PREVENT S.. OARS FROM ENTRIIG THE MALL COMMON AREA OR OTHER TENANT SPACES. X 58' ALL I'S Y DR MUSE TAKE THE FOLLOWING ACTION FOR THE START UP OF AIL B HVRE AC UNITS PRIOR TO WEND. THE PREMISES FOR BUSINESS CONTRACT. SH.L PROVIDE LANDLORD WITH WRITTEN VRIFI.TION FROM AN AMARLIE.DD REE.SDC 5FATIVE OF THE INSTALLED HVAC EQUIPMENT IAN FACTI 8 ER THAT TIE HVAC EQUIPMENT IS INSTALLED AND OPERATING IN ACCDRDAMf WITH THE EQUIPMENT M NFACTLER'S REQUIREMENTS. IN THE EVENT THE LANDLORD ORD DETERMINES TENANT'S HVAC EQUIPMENT IS NOT COMAE. Di ACCORDANCE VIM THE EQUIPMENT MANUFACTURER'S RECOMENDATIOS, LANDLORD'S FOLD REPRtE.NTATIVE SHALL , WITHIN FIVE C5) OATS FROM UNAIRDS WRITTEN NOTICE TO TENANT OR TENANT'S COTRCTOR OF SAFE, CQdECT SUCH OPFTRATIONAL DEFICIENCY. • EXHAUST FANS 1- EACH TOILET RAN SHALL FAYE A TOILET EXHAUST FAN, CONTROLLED BY A LIGHT SWITCH, SIZED PER CODE AND RATED AT MINIMUM .25'EXTETNRAL STATIC PRESSURE TOILET EXHAUST FAN SHALL BE COINECTED ]O LAlON..Q27'S TOILET EXHAUST DUCT. TOILET EXHAUST EARS SHALL . CEILING MOUNTED VIM INTEGRAL GRILLES, AND BADCIRAFTT DEFER. FAA SHALL BE PENN, GRE.HECK, MUTOE OR OTHER APPROVER 2. RCEF WANTED GREASE EXHAUST FANS SHALL BE BELT DRIVEN, UPBLAST CENTRIFUGAL TYPE APPROVED FOR GREASE LADEN AIR MMIRS SHALL BE INSTAL L F_D OUT [F THE AIR STREAM, COMPLETE WITH DISCONECT SWITCH. FANS SHALL BE SIMILAR 10'GREENE. A S EL CAFE, WET. MPA 96 REQUIREMENTS ALL ARE TO HAVE GREASE GUARD INSTALLED SEE DETAIL. 3. ALL FANS REQUIRED FOR RELIEF, MAKE -UP AIR OR EXHAUST (EXCEPT TOILET Rm0 SWILL BE AN IPBLAST ROOF MOUNTED AND OF A MTTSBB CORRIFUGAE TYPE WITH A BELT IR DIRECT DRIVEN ENCLOSED MOTOR OUTSIDE THE AIR STREAM. CLASS B TYPE MOTORS SHALL BE USED FOR HIGH TERPRATLRE APPLICATION. ALL ROOF MOUNTED FANS SHALL INCORPORATE A COWTFRRANCED BACK DRAFT DAMPER OR A MOTOR OPERATED HAMPER INTERLOCKED WITH FAN OPERATION AND A SERVICE DISCONNECT SNITCH AT THE FAN. POISE II, G2 AND FOODCOURT SHAD. INSTALL A SMOKE RELIEF FAN WITH MOTORIZED BAWER THE FAN CAPACITY SHALL BE 1 AND ONE HALF CFM PER SQUARE FOOT OF LEASEABLE AREA AT 0.25 INCH V. C • HOODED EXHAUST SYSTEMS HOLDS, DUCTWORK AND ACCESSORIES SHALL BE SIZED, CONSTRUCTED AMID INSTALLED PER MPA 96 AND ALL STATE AND LOCAL CODES, AND LANDLORD'S INSURANCE .DERWRITERS HOODS SHALL BELL L LISTED 2. DUCTWORK AND HOOD MATERIAL SHALL BE WELDED 16 GAUGE STEEL OR LB GAUGE STAINLESS STEEL IR AS OTHERWISE REQUIRED BY CODES STAINLESS STEEL CONSTRUCTION SHALL BE USED BELOW FINISHED CEILING UNLESS OTHERWISE APPROVED BY LANDLORD REPRESENTATIVE 3. ALL SEAMS AND JOINTS SHALL HAYS LIQUID TIGHT CONTINUOUS EXTERNAL WELDS 4. DUCTS SHALL BE INSTALLED WITHOUT FORMING DRIPS AND TRAPS WHICH MIGHT COLLECT RESIDES. SLOPE DUCT TOWARD HOOD ALL HOOD EXHAUST DUCTS SHALL BE INSULATED V1TH HIGH TEMPERATURE INSULATION. 5. THE AIR VELOCITY THROUGH ANY DUCT SHALL :ROT BE LESS THAN 1,500 FEET PER MINUTE NOR GREATER THAN 2200 FEET PER MINUTE. 6 ACCESS ODORS SHALL DE GASKETED AND PROVIDED FOR INSPECTION AND CLEANING AND SHALL BE INSTALLED AT EACH CHANGE OF DIRECTION 7. GREASE LADEN AIR SHALL BE DISCHARGED VERTICALLY ABOVE ROOF AT CODE REWIRED HEIGHT. TENANT'S CONTRACTOR SHALL FURNISH AND INSTALL 11 'CEASE WARD' SYSTEM FOR. ALL GREASE EXHAUST FANS. 'GREASE GUARD' SHALL BE . MAAFACTUED BY •GREASE GUARD' (1 -800- 284 -8273) 9. MAINTAIN MINIMA CLEARANCES BETWEEN DUCT AND OTHER SERI:.. AS REQUIRED BY CODE 10. INSULATE AND /OR ENCASE DUCT ABOVE CEILINGS. INSTALL AS REWIRED BY CODE AND PROVIDE CLEARANCES FROM COMBUSTIBLES AS REWIRED BY CODE, AA FLUES SHALL BE METALBESTBS TYPE B.. OR. IF MORE STRINGENT, AS REWIRED BY ROE. INSTALL IN A I IRE RATED SHAFT, NON COMBUSTIBLE CONSTRICTION V'TH COTE E RE LEAB(JM.. ...ACES AND INSULATED WITH FIRE RATED INSULATION. UP THROUGH ROOF. NO FIRE DAMPER SHALL BE INSTALLED IN FOOD EXHAUST. AD. FIRE DETECTION AND SMOKE CONTROL SYSTEM 1. THE HVAC SYSTEM SHALL INCORPORATE AN INTEGRATED SMOKE CONTROL SYSTEM AS FOLLOWS A. FURNISH AND INSTALL, IN THE SUPPLY DUCT SECTION OF THE ROOFTOP UNIT OR AIR HANDLER, UL LISTED IONIZATION DUCT TYPE SMOKE DETECTORS UXATE SMOKE DETECTORS IN AN ACCESSIBLE LOCATION. COMPLETE WITH DISCONNECT SWITCH FOR SERVICING AND RESETTING OF THE SMOKE DETECTOR WITH INDICATOR LIGHTS AE. AF AG. 2. PHASE I - a. 3. PHASE II - b. THE SMOKE DETECTOR, UPON ACTIVATION, SHALL SHUTDOWN THE HVAC SYSTEM, NOTIFY LANDLORD'S FIRE DETECTION AND SMOKE CONTROL SYSYTEM AND ACTIVATE A SEPARATE ROOF MOUNTED SMOKE RELIEF FAN FURNISHED WITH A MOTORIZED DAMPER AND INSTALLED ON A FABRICATED CURB PER DETAIL THE SYSTEM SHALL ACTIVATE AN AUDIBLE /VISUAL ALARM AT THE FRONT OF THE STORE UPON ACTIVATION 4. FOOD COURT AND Q SMOKE DETECTOR, UPON ACTIVATION, SHALL SMUT DOWN THE HVAC SYSTEM AND NOTIFY M APPROVED CENTRAL STATION MONITORING COMPANY. CONSULT CITY OF TIMVILA FIR A LIST OF U. L LISTED AND APPROVED CENTRAL STATION MONITORS TENANT SMALL INSTALL AN ADDITIONAL SMOKE DETECTOR AT THE STORE FRONT AND ADDITIONAL SMOKE DETECTORS FOR EACH 30' OF OPEN STORE FRONT. MINIMUM CFM CAPACITY OF ROOF MOUNTED NOTE RELIEF FAN SHALL BE ONE AND ONE HALF CFM PER SQUARE FOOT OF GROSS LEASABLE AREA AT 025 INCH WATER CULUN STATIC PRESSURE PROVIDE ALL ADDITIONAL CONTROLS REQUIRED TO PERMIT TIE SEQUENCE DESCRIBED ABOVE, INCLUDING CLOSING OF THE OUTDOOR AIR DAMPER IN THE HVAC UNIT. a. THE SMOKE DETECTOR SHALL, UPON ACTIVATION, SHUT DOWN THE HVAC SYSTEM, SAND AN AUDIO /VISUAL ALARM HORN LOCATED AT THE FRONT OF THE STORE. b. AS PHASE II, ITEMS b,c oral 0 AND AS PHASE I. 5. PROVIDE ALL ADDITIONAL CONTROLS REQUIRED TO PERMIT THE SEQUENCE DESCRIBED ABOVE. AC. TEMPERATURE CONTROLS, WIRING AND MISCELLANEOUS REQUIREMENTS 1. ALL CONTROLS SHALL BE A PNEUMATIC. CONNECT TO LANDLORD'S CENTRAL PNEUMATIC AIR. SYSTEM. 2. ALL OTHER CONTROLS SHALL BE A MAXIMUM OF 24 VOLTS ALL CONTROL WIRING SHALL BE INSTALLED IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE. - ALL EXHAUST FANS (EXCEPT TOILET EXHAUST FAN) SHALL INCORPORATE STARTERS. ALL EXISTING AND NEW WIRING IN PLENUM AREAS SHALL BE MODIFIED AND/OR INSTALLED IN CONDUIT OR BE CABLE LISTED FOR USE IN PLENUM AREAS. FIELD VERIFY ALL EXISTING WIRING TO DETERMINE THE EXTENT OF THE REQUIRED MODIFICATION 5. CONTROL AIRING FOR HVAC CONTROL SHALL BE MLTICOLORED CABLE (8) - 16 AVG WITH 600V JACKET INSULATION 6. THERMOSTAT FOR TEMPERATURE CONTROL SHALL BE OF THE PNEUMATIC TYPE, REVERSE ACTING, OR OTHER LANDLORD APPROVED. MODIFY INSTALLATION IF ALL EXISTING CONTROLS AS REQUIRED BY LANDLORD FOR PROPER OPERATION OF THE HVAC SYSTEMS 7. CONTRACTOR TB FURNISH 'AS BUILT' DRAWINGS OF THE TOPERATUE CONTROL SYSTEM INCLUDING ALL HVAC EQUIPMENT CONTROL DIAGRAMS AS SUPPLIED BY THE EQUIPMENT MANUFACTURER AND ALL FIELD INSTALLED WIRING AND CONTROLS. A0. TENANT SHALL INSTALL ROOF TREAD PADS AROUND ALL RAF MOUNTED El AND TO LANDLORD'S MAIN TRAFFIC AISLE. CONSULT LANDLORD RIME FOR APPROVED TREAD PADS. NO HVAC EQUIPMENT, DUCTS, ETC, SHALL BE INSTALLED IN DEMISING VALLS. PAINT ALL EXTERIOR EXPOSED METAL WITH MUST PREVENTATIVE PAINT. ALL INSTALLED EQUIPMENT AND ACCESSORIES AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED AR ALL TENANTS SHALL PROVIDE PROTABLE ADC FIRE EXTINGUISHERS AS REQUIRED BY THE LOCAL FIRE PREVENTION AUTHORITY HAVING THAAU LICIIW. EXTINGUISHERS SHALL BE LOCATED TO HAVE A MAXIMUM TRAVEL DISTANCE FROM ANY POINT IN THE TENANT SPACE TO AN EXTINGUISHER OF SEVENTY -FIVE (75) FEET. THE MINIMUM REQUIREMENT SHALL BE TWO EXTINGUISHERS WHICH ONE SHALL BE LOCATED IN THE SALES AREA AND ONE IN THE STORAGE AREA OR REAR OF UNIT.) AI. NO EQUIPMENT SHALL BE INSTALLED IN THE CODE REQUIRED EXIT CORRIDOR. A CLEAR 44 INCH MINIMUM IS REQUIRED. (VERIFY WITH ARCHITECT.). AJ. ALL TENANT'S ROOFTOP HVAC EQUIPMENT SHALL BE PROVIDED WITH A • MANUFACTURERS OPTIONAL CONDENSER OIL GUARD TO PROTECT. AGAINST HAIL DAMAGE, DEBRIS AND VANDALS 2Z1 RECEIVED TARTY OFTUKWILA SEP 1 4 2000 : 1HMIT CENTER ALL INSTALLED EQUIPMENT, ACCESSORIES,' AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. SEATTLE, WASHINGTON soUTHCENTE MECHANICAL DETAILS SPECIFICATIONS Sheet 3 of 6 SUI rfe. P!.12 UNIT NUMBER 114 mcrytel FIPPLE DBA THIS SHEET & TTO.01 MUST BE INCLUDED AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS AND FOR BUILDING PER MITE The Richard E. Jacobs Group 4Q REVISED 7/15/98 © REVISED Q REVISED Ql REVISED DRAWN BY REARED BY: ME NAME: SCNTTM3 REVISONS 6/13/es DATE J08 NUMBER DATE ' °RAM C NUMBER FLOOR SLAB SECURE BASE TO CURB WITH LAG SCREWS 12' D.0 MIN. OF 2 PER SIDE FABRICATED CURB SEE CURB DETAIL „ .. _ S RI MOTOR �I• .. _.. EXISTING METAL DECK M ' RIGID CONDUIT BY ELECTRICAL MOTOR OPERATED DAMPER CORNER TO BE CUT FOR CONDUIT ROUTING DUCT INSULATION SEE SPECIFICATION SECURE BASE TO CURB WITH LAG SCREWS 12' D.C. MIN. OF (2) PER SIDE FABRICATED CURB— SEE CURB DETAIL EXISTING METAL DECK DUCT INSULATION SEE SPECIFICATION REMOVE CONCRETE FLOOR FOR PIPE PENETRATION ONLY. DO NOT CUT REBAR REPLACE CONCRETE SLEEVE I /2' CLEAR MIN., 3/4' CLEAR MAX. PACK WITH OAKUM & APPLY SEALANT AT TOP FOR GAS SEAL. FLUSH VITH FLOOR. 1/2' WIDE x 3 /4'DEEP RECESS AT PERIM. OF CONC. PATCH. FILL WITH SEALANT FOR GAS SEAL ECHANICALLY ROUGHENED JOINT PIPE FORM UNDERSIDE OF SLAB ANGER TUNNEL UNDER EXISTING SLAB FOR PIPING STUCTURAL SLAB PIPE PENETRATI ❑N DETAIL 19 NTS N.T.S. ■ NOTE. SEALANT TO BE MIN. OF 1/2' THICKNESS OF DEC BETASEAL NO. 169 DEC DIVISION OF ESSEX CHEMICAL CORPORATION OR APPROVED EQUIVALENT OF MINNESOTA MINING AND MANUFACTURING CO., DR BENJAMIN FOSTER. NOTE ALL DUCTWORK BELOW SLAB SHALL BE CONSIDERED CONFINED SPACE. INSECT SCREEN RESILIENT GASKET SEAL INTAKE BASE EXISTING INSULATION . "----SECURE CURB TO DECK W/ SCREWS 12' O.C. MIN. OF 2 PER SIDE. 3'.3'x1/4' ANGLE FRAMING (4) SIDES- SEE CURB DETAIL 6 NOTES 1. H.V.A CONTRACTOR TO COORDINATE INSTALLATON W /LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING I COUNTERFLASHING INSTALLATION. ❑,A. INTAKE GRAVITY RELIEF DETAIL N.T.S. TT -12 MOTORIZED DAMPER NOTES■ AS REQUIRED GREENHECK GRS- SERIES OR EQUAL RESILIENT GASKET SEAL EXHAUSTER BASE EXISTING INSULATION SECURE CURB TO DECK W/ SCREWS 12 O.C. MIN. OF (2) PER SIDE. I. H.V.A.C. CONTRACTOR TO COORDINATE INSTALLATON W /LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING & COUNTERFLASHING INSTALLATION. EXHAUSTER DETAIL (TOILET; SMOKE, MISC,) TT -11 3'.3'4/4' ANGLE FRAMING (4) SIDES- SEE CURB DETAIL EXISTING ROOFING MEMBRANE /ROOF SECURE BASE TO CURB WITH LAG SCREWS 12' G.C. MIN. OF 2 PER SIDE ONE. PIECE WELDED ALUMINUM FAN SUB -BASE CONTINUOUS PIANO TYPE PIANO HINGE FABRICATED CURB SEE CURB DETAIL EXISTING ROOF DECK RIGID CONDUIT BY ELECTRICAL MOTOR OPERATED DAMPER CORNER TO BE CUT FOR CONDUIT ROUTING GAS LINE ON ROOF GAS LINE SUPPORT SFF_RFTAIE 0 CLEVIS HANGERS - PIPES 1 -1/4' A SMALLER 8' -0" MAX. O.C. PIPES 1 -1/2' A LARGER 10' -0" MAX. O.C. GREASE COLLECTION DEVICE IS REQUIRED. INSTALL PER MANUFACTURER'S REQUIREMENTS. TENANT MUST EMPLOY GREASE GUARD, TO INSTALL CALL 1- 800 -284 -8273 FOR INSTALLATION 16 GA. FABRICATED CURD -SFE DFTAI SEE DETAIL 26 FOR FRAMING REQUIREMENTS RESTAURANT GREASE FAN AND PAN DETAIL 21 N.T.S. EXISTING ROOF ANGLE IRON COPED EACH END TO FR OVER JOIST CLAMP OR WELD ANGLE TO JOIST. STEEL WASHER ALUMINUM ROOF UPBLAST FAN REQUIRED FREE AREA SIZED ON 500 FT. /MIN VELOCITY GAS VALVE RESILIENT GASKET VENTED CURB EXTENSION (AIR VENTS ON ALL(4) SIDES) RESILIENT GASKET FLASHING BY GREASE GAURD CONTRACTOR RELIEF /ROOF EXHAUST FAN DETAIL N.T.S. - TT -10 2' -0" MAX. DISTANCE 1ST SUPPORT i t FOR PIPE AND/OR CONDUIT FLASHING THRU ROOF SEE DETAIL® 4" OPT LEG 3" MIN. ABOVE ROOF DOUBLE NUTTED H CIS ONE DIRT LEG MIN. 6" AT EACH CHANGE OF ELEVATION_ 3/8" ROD (MIN.) ALUMINUM ROOF UPBLAST FAN RESILIENT GASKET SEAL FAN BASE HOLD DOWN CLIP EXISTING INSULATION SECURE CURB TO DECK W/ SCREWS 12' O.C. MIN: OF 2 PER SIDE. NOTE H.V.A.C. CONTRACTOR TO COORDINATE INSTALLATON V /LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING & COUNTERFLASHING INSTALLATION. GAS PIPE THROUGH ROOF DETAIL N.T.S. NOTES L FOR BALLAST SYSTEMS REPLACE BALLAST AFTER WORK IS COMPLETED. 2. NEW INSULATION TD MATCH EXISTING INSULATION HEIGHT AND OF THE SAME OR GR THERMAL RESISTANCE VALUE. 3. ROOFING TO BE INSTALLED AND FLASHED -IN WITH MATERIALS TO MATCH EXISTING INSTALL MATERIAL PER MANUFACTURER'S RECOMMENDATIONS. 4. HVAC CONTRACTOR TO COORDINATE INSTALLATION WITH LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING AND COUNTERFLASHING INSTALLATION. 5. USE SELF DRILLING FASTENERS FOR METAL DECK,TUGGLES FOR GYPSUM DECKS. TT -2I -- NON DUCTED EXHAUST AIR SYSTEM ABOVE CEILINGS INSTALLED 2'. DEEP LIQUIDTIGHT DRIP PANS \ \---3'x3'x1/4' ANGLE FRAMING 6 (4) SIDES- SEE CURB DETAIL 2 - GROUND JOINT UNION EXISTING INSULATION 3 ".3'x1 /4 ANGLE ANCPAR PIPE TO ANGLE WITH STD. U -BOLT GAS PIPE MIN_ 1 -1/4" LOCATE AWAY FROM BUILDING VAIL & 15'-Dr FROR4 OUTSIDE AIR INTAKES ROOFING EXTEND FLASHING OVER TOP BF INSULATION END FASTEN AT 8'U.C. HUMANE PAD 18'x18' 01D42 EXISTING INSULATION EXISTING ROOF DECK IiiS TT ODN.:— FIR COTICUIT ROOF AIL BOLTED PIPE CLAMP CONTINUOUS FASTENING STRIP AND APPROVED FASTENERS AT B'O.C. CAP SEAL OFF METAL DECK FROM DUCT OPENING V/26 GA. SHEET FETAL ALL SIDES 1/4' x 6' LG. GALVANIZED STEEL LAG BOLTS- BOLTS TO HOLD BLOCKING TOGETHER FASTEN PIPE CLIP TO M BLEDING „i I' AS 4' REVD PLAN PLINE. CONTRACTOR IS RESPONSIBLE TO PROVIDE GAS LINE SUPPORTS FOR ALL GAS LINES INCLUDING TENANTS PIPE SLEEVE AND CLIP. PVC PIPE SLEEVE SEEM VIDE 20 GA. GALVANIZED STEEL PIPE CLIP '.FOR THE PVC SLEEVE. C2) 4'x4' WOLMANIZED WOOD BLOCKS NOTES. SECTION L SUPPORT REQUIRED. EVERY IF -0' D.C. AND AT CHANGES IN DIRECTION 2, INCREASE HEIGHT.. AS. REWD FOR ROUTING ABOVE ROOF MOUNTED ACCESSORIES SOON AS EXPANSION. JOINTS. a PVC PIPE SLEEVE SHALL BE THE NEXT SIZE PIPE DIAMETER LARGER THAN THE OUTSIDE DIAMETER OR THE PIPE - T� OUTLINE OF EQUIPMEN NOTE 4' MIN. VIBRATION ISOLATION GROMMET a RUBBER SHEAR PAD OR SPRING ISOLATOR FOR ROOF MED. EQUIPMENT PATE SHEET METAL CURB CAP PATE CO EQUIPMENT SUPPORT STYLE ES -2B 5- 1/2'x15' MIN 18 EA.- ALL WELDED FIRE TREATED WOOD BLOCKING. ALL (4) SIDES OF CURB. NOMINAL 6' VIDE x THICKNESS TO MATCH INSULATION THICKNESS. NOTCH WOOD TO LAY FLAT OVER CHANNEL AX. REINFORCED JOIST INDICATED ON MECHANICAL AND /OR STRUCTURAL PLANS WITH L STUB COLUMNS 2.. BLOCK OUT AREAS 3. JOISTS - MARKED WITH AN ASTERISK (4) 4. VERIFY LOCATION WITH LANDLORD REPRESENTITIVE UNISTUT %r pT EALH EN➢ VITH 1/4' LAG BOLTS (P -40W CHANNELS) SUCTION DR HDT GAS INSULATED LIQUID ELECTRICAL CDNDUI UNISTUT PIPE CLAMPS NOTE LEI U LINE PIPE CLAMP TO BE USED AS A GUIDE ONLY. INSTALL b' LENGTH msMLAnoN SLOPE AWAY FROM PIPE CHAS UNISTUT PIPE CLAMP PIPING CURB SUB'PORT PATE CO. ES STYLE IA 12 HIGH MIN.LB GA. V /2'x4' NAILER Iii CURD BE MAX. MY -D' 0.c HUMANE PAD ON TOP OF ROOFING EXISTING METAL DECK ROOF JOIST PLAN SECURE CHASE TO METAL DECK AT V4 POINTS WITH 2.2x1 1/2 W DE 16 GAUGE SHEET METAL CLIP ANGLES AND FASTEN TO CHASE. WITH SCREWS SECTION — °A' CLOSURE PIECE BELOW PIPING AND BEHIND SECURE TO CURB CAP. SECTION A INSUL TE THE LIQUID LINE TO A POINT I' REYDND FO.LER- SEAL ENDS B • PLAN TAL DECK OLT CHANNEL TO EACH JOIST CHANNEL SUPPORT ON TOP OF DECK EQUIPMENT SUPPORT CURB COVER SECTION —'B" ROOF MED. EQUIPMENT LAG BOLT WITH FLATWASHER SECURE CURB CAP TO CURB WITH SHEET METAL SCREWS AT 12 PATE WOOD NAILER • RIGID INSULATION THICKNESS TO MATCH NAILER OVERHANG - ADHERED TO CURB CUT INSULATION TO MEET WOOD BLOCKING EXISTING INSULATION EXISTING METAL DECK FASTEN CURB TO CHANNEL AT 24' D.C. MAX. CAIN. 4 PER CURB> CONDENSING UNIT AND OTHER SPECIAL 18 ROOF MOUNTED EQUIPMENT SUPPORT DETAIL NTS TT -18 CUT SLOTTED MOLES IN COVER AND CLOSURE — CONDUIT PIECE FOR PIPING I /4• SMALLER THAN OVERALL UL AC SIZE. COMPRESS INSULATION AND FORCE INTO PLACE. CAULK PERIMETER OF PIPES INSULATED COVER BOLT CHANNEL TO EACH JOIST WITH MACHINE BOLT, NUT AND WASHER. nn NOT DRD I JOIST. NOTES 1. UNITS UP TO 1880 LBS. TOTAL WEIGHT SHALL BE SUPPORTED WW2, JOISTS. 2. UNITS GREATER THAN 1880 LBS. BUT LESS THAN 2800 LBS. TOTAL WEIGHT SHALL BE SUPPORTED ON MIN.(3210ISTS. 3. HVAC CONTRACTOR TO ALLOW ROOFER TO INSTALL COUNTERFLASHING PRIOR TO INSTALLING PATE CURB CAP. UCTIO N LIQUID fATE ALL SEAMS TO BE SOLDERED WATER TIGHT TAL COVER w"" INSULATRW JW NTI®N VI T. METAL CURB FASTENED —CLOSURE PIECE FASTEN COVER AT 12'0.C. TIRO CURB CAP RESILIENT GASKET RIGID INSUL TD NMTCN THICKNESS DF WOOD NAILER AV ERE TO CURB FABRICATED URB. SEE CURB DE 26 SECURE CURB TO METAL DECK AT 1211C MAXAtlN E. PER SIDE) i8 GA GALV 6'0IA. GALV. METAL REFRIGERANT MTL CURB CHASE FOR LOWER TENANTS SECTION —'C' ONLY IO lira 0 -• vl RECEIVED �a CRYOFTUKWILA A REVISED SEP 1 4 2000 I MI PEsmrro N .. NOTES 1. HVAC CONTRACTOR TO COORDINATE INSTALLATION WITH LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT PLASHING AND COUNTERFLASHING INSTALLATION. 2. CHASE AND COVER INSTALLATION - 1' THICK NAPA COATED, PORED ON 4' CENTERS AND FILLED TO SLEET METAL 2 CAULKING TO BE SILICONE BASE AND WATERPROOF. REFRIGERANT PIPING �\ so UTHCENTER MECHANICAL DETAILS AND SPECIFICATIONS Sheet 4 of 6 REMELT BY: REVISED. REVISED OLE NAME SCNTTM4 DRAWINQ NUMBER: SEATTLE. WASMNCTTXN Suite !<<•72 UNIT NUMBER '(i4�t plr�L DBA THIS SHEET & TTO -01 MUST BE INCLUDED AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS AND FOR BUILDING. PERMITS The Richard E. Jacobs Group SONS AD NUMBER , . O 7 /1£ /SD 1/15/98 ..7/10/95.. APPLIANCE HEAT GAIN CALCULATIONS APPLIANCE NO. FUEL/ MOTORS INPUT K.W. FACTOR INPUT BTUH SENSIBLE FACTOR SENSIBLE HEAT GAIN LATENT FACTOR LATENT HEAT GAIN r a /VIA GAS .33 .17 ELECTRIC 3413 .33 .17 ao o Uw o o GAS -- .10 _ ELECTRIC 3413 14 Li w w DC N h os MOTORS HP 2545 .30 ELECTRIC 3413 TO OTHERS TOTALS KITCHEN EXHAUST FAN MANUFACTURER MOTOR H.P. CFM POWER V/ HZ/ 0 MODEL FAN R.P.N. ESP DRIVE BELT MOUNTING CURB 2'x4 FIRE TREATED WOOD NAILER. SECURE TO CURB AT 12"0.C. (MIN. 2 PER SIDE). FABRICATED 16 GAUGE GALVANIZED SHEET METAL ALL WELDED CONSTRUCTION. PAINT AFTER PAINT WITH RUST RESISTANT AFTER FABRICATION. FABRICATE HGT. OF CURB SO THAT HGTABV.ROOFING SURFACE IS A MIN. 10'. FOR HOOD EXHAUST SYSTEMS SEAL OFF OPENINGS IN DECK W/ METAL PLATE SECURE CURB TO DECK WITH SCREWS AT B" O.G. 3":3'x7/4" ANGLE FRAMING ALL SIDES OF DUCT PENETRATION, WELDED OR BOLTED TOGETHER. COPE ANGLES PERPENDICULAR TO JOISTS TO ALLOW TOP LEG TO SET ON TOP CHORD OF JOIST. WELD OR CLAMP ANGLES TO JOIST. ANGLE MAY BE OMFTTED ON SIDE OF DUCT OPENING WITHIN 6" OF JOIST. I REINFORCED JOISTS INDICATED ON MECHANICAL AND /OR STRUCTURAL PLANS WITH: BLOCK OUT AREA. 2. JOIST MARKED W/ AN ASTERISK. • 4 MIN. UKP ANGLE OVER JOIST MIN. 5'x6.7 pp/FT. CHANNEL SUPPORT ON TOP OF DECK 6 -0' TWO OC. MAX. SPAN JOIST MIN. OUTLINE OF R.T.U. METHOD (1 (TYPICAL FRAMING FOR RTU'S UP TO 1680 CBS. TOTAL WEIGHT) RTU STRUCTURAL FRAMING PLAN N.T.S. MAIN WALKWAY BY LANDLORD BY TENANT FULL PERIMETER R.T.U. CURB SEE NOTE #2 12" MIN. SEE NOTE #1 FA a E P 11■-- alrak MIll 1 TREAD PAD (CONSULT LANDLORD ROOFER FOR TREAD PAD) i L i 1/2 SECTION 'A' USE THIS DETAIL FOR NON - REMOVEABLE EQUIPMENT 1 1/ METAL DECK. FI ANGLE VIOL REVD WHEN DECK OPENING IS N 6' OF J015T 3x3:1/4 DUCT OPG. FRAMING TYP. 4 SIDES /OPG POWER k CONTROL WIRING THRU ROOF SFF DFTNL Og WHEN CURB PROJECTS BEYOND JOIST MORE THAN 18 XT JOIS IXTEND . CHANNEL TO NE ROOF TREAD PAD LAYOUT 86 N.T.S. TT -RR -IIIRW.MI � � � �6." N t elliiiiiiiiii111 _ now � mos I i E�mGli�i ur 1 III FIRE TREATED BLOCKING ALL (4) SIDES ITERED JOINTS WELDED AND OF CURB. NOMINAL 61YIDE x THICKNESS GROUND SMOOTH ON CURB (FYP.) TO MATCH INSULATION THICKNESS. . 2x2" FIRE TREATED WOOD NAILER. SECURE TO CURB AT 12"0.C.(MIN (2) PER SIDE) USE THIS DETAIL FOR REMOVEABLE EQUIPMENT RI.,ID INSULATION TO MATCH THICKNESS OF NAILER. ADHERED TO CURB. CUT INSULATION TO MEET WOOD BLOCKING TA METAL DECK EXISTING JOIST NOTES• 1. INTERIOR DIMENSIONS TO BE DETERMINED BY SPECIFIC EQUIPMENT. SEE DETAILS. 2. EXTERIOR MIN. DIMENSIONS OF CURB FOR FLASHING AND COUNTERFLASHING SHALL BE 12 "x12 ". EXISTING INSULATION TO REMAIN. REPLACE ALL DAMAGED INSULATION TO MATCH EXISTING. 2g DETAIL OF FABRICATED CURB N.T.S. TT -26 FOR HOOD EXHAUST OR WHERE CODE DOES NOT PERMIT TREATED WOOD BLOCKING. OMIT WOOD BLOCKING AND UTILIZE ROOFING MATERIAL PER CODE. 5 x 6.7# /FT. CHANNEL SUPPORT ON TOP OF DECK SPAN. MINIMUM OF 3 JOISTS LAP 51 NIN. JO1ANGLE OVER OF2 OUTLINE OF R.T.U. FULL PERIMETER ROOF R.T.U. CURB DECK MINIMUM. OPENING 6 WITHIN 8' OF JOIST ANGLE FRAMING FOR DUCT PENETRATIONS TYP. 4 SIDES /OPG 4' MIN. Hum iminsitmmor vim d dl ANGLE NOT REVD WHEN METHOD #7 (TYPICAL FRAMING FOR BTU'S BETWEEN 1880 LBS. ID 2800 LBS. TOTAL WEIGHT) RTU STRUCTURAL FRAMING PLAN GFNFRA_ NGTrx. 1. FIELD VERIFY LOCATION OF RTU PRIOR TO INSTALLATION. 2. ALL SHOWN BY TENNIT COMB UNLESS OTHERWISE NOTED 3. FRONDE INSULATION IF KM NOT PERMITTED BY CODE RTU STRUCTURAL FRAMING PLANS AND SECTION N.T.S. TT-1 SEE NOTE #2 STAINLESS STEEL CLAMPING RING ROOFING MEMBRANE INSULATION ROOF JOISTS LAP ANGLE MIN. 2" OVER JOIST ANGLE FRAMING FOR DUCT PENETRATION PLAN REINFORCED JO INDICATED ON MECHANICAL AND/OR R.. STRUCTURAL PLANS WITH: 1. BLOCK OUT AREA 2. JOIST MARKED W/ ASTERISK. • DOLT CHANNEELL TO EACH JGSi (lYP) POWER k CONTROL WRONG THRU ROOF SAT OFTAA O VENT PIPE TYPICAL DETAIL - LEAD - BUR N.T.S. METAL DECK FOR PLUMBING VENTS TURN LEAD FLASHING DOWN INTO VENT PIPE A MIN. OF 1" BELOW TOP OF PIPE SOLDER JOINT \I••i 4 LB. VIRGIN LEAD FULL PERIMETER ROOF -, TOP E CURB CU PROVIDE STEEL SHIMS RB i CHANNEL O 24 IF REVD FOR LE1F..uNG. . ucr CONNECTION NOTES' 1. FOR BALLAST SYSTEMS, REPLACE BALLAST AFTER WORK IS COMPLETED. 2. 4 LB. LEAD FLASHING SHALL BE 1/4" MAX. DIAMETER LARGER THAN PIPE ALL JOINTS TO BE SOLDERED. 3. FLANGE. SHALL BE. SET BY. ROOFER. CONTACT L.L. FOR UST OF APPROVED ROOFING CONTRACTORS 4. ALL ROOFWORK TO BE PERFORMED BY MALL APPROVED ROOFING CONTRACTOR 5. VENTS SHALL BE A MINIMUM OF T0' -0" FROM OUTSIDE AIR INTAKES. SET CURB LEVEL YAMPA UNIT MEWS. RECOMMEND... RESILIENT GASKET CONTINUOUS FIRE TREATED WOOD BY UNIT MANUFACTURER CONNECT TO LINO DUCT IJNEN -- WHERE REO'0 'METALBESTOS' TYPE RV FOR B" OR SMALLER TYPE QC FOR 10" OR LARGER DOUBLE WALL "METALBESTOS' TALL CONE TURN DOWN FLASHING FLANGE 2' ALL SIDES TO FORM CURB CAP. (SOLDER CORNERS.) RESIUENT GASKET 3' x 3' x 1/4' ANGLE FRAM. ALL SIDES OF DUCT PENETRATION, BOLDED OR BOLTED TOGETHER COPE ANGLES PERPENDICULAR TO JOISTS TO ALLOW TOP LEG TO SET ON TOP CHORD OF MIST_ WELD OR C AY O LAMP ANG TO''' ANGLE T M IN WITHIN " - SID DUC OPENING WITHIN OF JOIST. MINIMUM CLEARENCE - MIN. OF 3' -0" HEIGHT SHALL BE AS REVD BY LOCAL CODE LOCATE 25' -0" FROM BLDG. WALL AND 15' FROM OUTSIDE AIR INTAKE CONTACT LANDLORD. NOTES; 1. H.VAC. CONTRACTOR TO COORDINATE INSTALLATION W LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING & COLA WISFAUATWN. 2. CURB INTERNAL SIZES: FOR FLUES 3" THRU - ;3" cum FLU 6' THRU 8" ROUND - 12 "x1 CURB, FOR FLUES GREATER THAN E" ROUND CONSULT WITH THE LANDLORD. GAS FLUE THRU ROOF DETAIL 0 N.T_S. TT -4 .l NA%FR ..„-. A ��L� LTA :, 1>•I It t ' f (8� INSUL TO , F 1 TR ADDA CUT NAIL TO MEET WW W■ N W D TO CURB ADT$Jim 1`me ROOFING . WOOD FROCKING MilrAWAWAIV 'am I ` WW_ - wa i 1CmsI PSL1g A�//L\w/IAr',- i v v/ _ _ 5' 67 - SEE NOTE #2 STAINLESS STEEL CLAMPING RING PRE- MOLDED PIPE SEAL RUBBER ROOFING MEMBRANE BOLT CHANNEL TO EA JOIST W/W - H MOLT NUT Jk 5/A4i DO NOT DRILL_ JD1ST. FIRE TREATED ROOD BEOCKUK. ALL FOUR SIDES CF CURB NOM. 6' 'R % TFIK;qNE$. TO MATCH INSULATEN THICKNESS B / LT PDID. MACLWE SECTION A EARlgF CAP � "METALBESTOS" STORM COLLAR SET IN SEALANT SECURE THEE CONE TO CURB MIN_ 2 PER SSE 0 12 O.C. FABRICATED CURB SEE CURB QETA>L� SECURE CURB TO DECK WI SCREWS 12" O.C. tL (2) PER SIDE SECURE FLUE TO DECK AT 1,4 POINTS MATH MIN. OF (4) 2"x1 -1/2 WIDE 16 GA. SHEET METAL 0.1P ANGLES RIVETED TO FLUE, SECLDREO TO DECK. FOR MODEL OC VENTS USE" MEI7.BE_STOS' SUPPORT PLATE. OLS PF.SIRE FMLIATOR (WHORE REQUIRED) GAS COCK WATER CUT -OFF MASTIC SPLICING CEMENT LAP SEALANT GAS SERVICE (IRO. REQUIEM) g i i IT DRIIBB INSULATION I I Np7E: DO NOT TRIM DECK FLANGE 1. PRE - MOLDED PIPE SEAL CANNOT BE CUT VERTICALLY TO BE INSTALLED. 2. PRE-MOLDED PIPE SEAL MUST HAVE INTACT RIB AT TOP EDGE REGARDLESS OF PIPE DIAMETER. 3. WHEN PREFABRICATED PIPE SEAL CANNOT BE INSTALLED, USE FIELD FABRICATED PIPE'. SEAL. SEE ALTERNATE PIPE FLASHING DETAIL 4. FOR BALLAST SYSTEMS, REPLACE BALLAST AF - TER WORK IS COMPLETED. 5. FLANGE SHALL BE SET BY ROOFER. CONTACT LL FOR UST OF APPROVED POOFING CONTRACTORS 6. ALL . ROOFWORK TO BE PERFORMED BY MALL APPROVED ROOFING CONTRACTOR 7. VENTS SHALL BE A MINIMUM OF 10' -0 ". TYPICAL DETAIL - PREMOLDED RUBBER ROOF N_T.S. - - EXISTING INSULATION EXISTING METAL DECK MIN. 12 THICK CONC. SPLASH BLOCK 24524' HUWAE ROOF PAD SPCA BACK GRAVEL MASTIC TO ROOF INSULATOR METAL DEIX JOST APPLIANCE SCHEDULE APPLIANCE NUMBER Nl/ APPLIANCE FUEL TYPE GAS /ELECT. FUEL RATING BTUH /KW HOODED UNHOODED TO SUPPLY AIR MAIN VOLUME DAMPER 1 -1/2" THICK FIBERGLASS INSULATION W/ FOIL FACING • EXISTING OPENING TO MI COVERED WITH A MIN. OF 20 GA. GALV. PLATE FOR OPNGS. W LESS. FOR DIMENSION i " OR LA RGER THAN i LE 6. USE LARGER USE METAL DECK OE SAME PROFILE AND GAUGE AS ExlsnNC. SECURE TO ROO DEC WITH SCREWS 6 O.C. INTO TOP OF FLANGE K MAST BE SURTE PPOD RIO'N METAL DECK GALVANIZED SHEET METAL DUCT FLEXIBLE DUCT MOUNTING DETAIL N.T.S. STING ANGLE ( BANE" PROVIDE NEW 3 3 1//4 GLE FRAME IF NONE IXI575) �Ig PLAN OF EXISTING ROOF DECK NEW ROOF INSULATION 1141! /INlti!1!N/lU!1Np�1!lll tirai! !P!!ANRlRItN! WIN� LW 1=M S ''AM EMIN NIN.' SECTION 1 - 1 (FOR OPENING LARGER THAN 181 MIN' NEW ROOF INSULATION 20 CA GALV. STEEL rn IC SECTION 2 - 2 (FOR OPENINGS 16' k SMALLER) 7!-UN!i1 12 111111! 1l OLl1R71!1101}1t�.Y!li!!i!i1H11! ���-_' ROOF � AWE METAL STRAP CLAMP (TYPICAL) 2 PLACES INSULATED FLEXIBLE CONNECTION. (MAX. 5' -0") IN VERTICAL ONLY.' SUPPLY AIR DIFFUSER. TT -99 JOIST NEW INSULATION FQ!T OPENINGS 16 &SMALLER FOR OPENINGS LARGER THAN 16' i. NEW INSULATION TO MATCH EXISTING INSULATION HEIGHT A OF THE SAME OR GREATER THERMAL RESISTANCE VALUE. 2. ROOFING TO BE INSTALLED AND FLASHED -IN WIR1 MATERIALS TO MATCH EXISTING. INSTALL MATERIALS PER MANUFACTURER'S REcommENDATioNs. 3. IF METAL DECK FOR OPENINGS LARGER THAN 16" IS NOT AVAILABLE. CONTACT LANDLORD'S STRUCTURAL ENGINEER. JOIST NEW METAL DECK TO MATCH TERNATE PRO 5T. PROFILE FIL ES ARE ALFIL ET RNITTED M NEW PROFILE WILL N WI7H EXISTING. RECEIVED CITY OFTUKWILA SEP'i 4 2000 PERMIT CENTER so UTHCENTER MECHANICAL DETAILS AND SPECIFICATIONS Sheet 5 of 6 THIS SHEET & TTO.01 MUST BE INCLUDED AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS AND FOR BUILDING PERMITS DRAWN BY: Sa bre P412 UNIT NUMBER 1G ricroce !PL ; DBA REMSIDI BY:. 2Q REVISED REVISED FR.E NAME SCNTTMS (AWING NUMBER: SEATTLE, WASHINGTON The Richard E. Jacobs Group REVISIONS DA JOB DATE 7/15/1[6 GALVANIZED ANIEED PIPE STRAPS W CADIUM PLATED BOLTS (TYPICAL) CONDUIT - NOTE: 3'x3'x1/4" GALVANIZED D1 STEEL ANGLE 6' -0' O.C. �LFI] 1/2' EXPANSION SHIELD EQUIPMENT PAD CLEANOIIT INSTALLED BY LANDLORD (SEE NOTE 3) PVC TO A MAXIMUM OF--/ 9' - 0' ABOVE FIN. FLR. PIPING SHALL BE USED CAST IRON NO HUB BELOW UPPER LEVEL FLOOR SLAB TO SERVE UPPER LEVEL TENANTS. I �s EXISTING - -Y BY LANDLORD CAST IRON SPOOL PIECE PIPE SUPPORT DETAIL NTS TT -135 MIN NO HUB CAST IRON PIPING ABOVE g' -0' COUPLING PVC /ABS STAMPED ASTM # D2665 -78 COUPLING (SEE NOTE 6) (SEE NOTE 3) r rl / i 1 1 I /I I I II ! i l ll I Tao ` — 7T _ - FLU \L JP INVERT ELEVATION AS SHOWN ON LANDLORD'S DRAWINGS SEE NOTE 5 FOR ALTERNATE SANITARY CONNECTION 1. TENANT SHALL CONNECT SANITARY DRAIN TO CONNECTIONS PROVIDED BY LANDLORD. 2. TENANT SHALL NOT MODIFY LANDLORD'S DRAIN OR MAKE CONNECTIONS TO SANITARY MAIN. 3. ABOVE AND UNDERGROUND COUPUNGS SHALL BE - CLAMP -ALL" DRAIN COUPLING MODEL -HI -TORO 125. 4. NO PVC PIPING SHALL BE ALLOWED IN RETURN AIR PLENUMS. 5. IF EXISTING LANDLORD PROVIDED UPPER SANITARY TENANT CONNECTION CANNOT BE USED, CONTRACTOR SHALL USE LOWER ALTERNATE SANITARY CONNECTION. 6. TENANT MAY USE CAST IRON BELL AND SPIGOT WITH APPROVED COMPRESSION FITTINGS BELOW GROUND. TENANT SANITARY PIPING DETAIL 4D N.T.S. GALVANIZED NUTS ROOF ROOF MOUNTED EQUIPMENT SUPPORT DETAIL NTS TT -135 ..a 1, AL dr N / % % %� o/ %�� / ,,;,, , r- it rin.„, , _,.. - rw , 02 , ,(; I / / Ai • NORDSTROM O I O ) 'I LH O D I FOOD COURT L . r JCPENNEY NORDSTROM SEARS NOTE 1. THE 'SPECIAL BUILDING CONDITIONS' NOTED ON THIS DRAWING SHALL BE CONSIDERED BINUXSIG /CONSERUCTIDN RESTRICTIONS. ALL CONDITIONS MUSE BE FIELD VERIFIED BY TENANT. 2. NOE OF THE NOTED C:.`LYPP..ONS MAY BE ALTERED 84 ANY WAY. NO FLOOR PENETRATIONS ARE PEI:MATED UNLESS RENEWED AND APPROVED BY THE LANDLORD'S ENGINSERS AND ALL PRESIDING GOVERNMENTAL AIOIHORIDES_ LANDLORD'S O.A. DUCTS 3. THERE ARE LOCATIONS BELOW THE FLOOR SLAB AT WHICH SPECIAL EQUIPMENT HAS BEEN LOCATED. FIELD VERIFICATION OF THESE IS THE TENANTS RESPONSIBILITY. 4. UNDER FLOOR AREAS ARE HAZARDOUS LOCATIONS DUE TO CONFINED SPACES AND FLAMABLE GAS FORMATION. Q 5. DO NOT CHANNEL FLOORS. STRUCTURAL DAMAGE WILL RESULT. L t JCPENNEY mW z u RE CENED oITYO -, SEP 1 4 2000 AW SOUTHCEINTE REVISED © REVISED A REVISED. DRAWN BY: SCAM VENSEB BY: FILE NAYS DCNTM6 SEATTLE; WASHINGTON MECHANICAL DETAILS AND SPECIFICATIONS. Sheet 6 of 6 °RAMC NUMBER )ire F6.72 UNIT NUMBER TO 0 Mofte DBA THIS SHEET & TTO.OI MUST BE INCLUDED AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS AND FOR BUILDING PERMITS The Richard E. Jacobs Group RDASBHS 6/28/98 5 / 7 /BA DATE 1 /16/96 JOB NUMBER DATE BUILDING PERMIT INFORMATION In order to obtain a Building Permit from the City of Seattle, the following procedure will be required: Applications for building permits are submitted to the Department of Community Development. Upon receipt, plans are routed to the City's plan checker and if appropriate to the Fire Department, Planning Division, and Public Works Department. The following documents are required: 1. A completed building permit application form. 2. Two (2) copies of working drawings, to include, but not limited to, the following: a. Site plan b. Overall building plan c. Floor plan of TENANT space d. Construction details 3. Plan Review Fee to be paid at time of application. City of Tukwila Building Division 6300 Southcenter Blvd. Tukwila, WA 98188, Tel: 206/431.3670 FOOD & RESTAURANTS Food handling or restaurant type TENANTS shall submit two (2) sets of plans to: Seattle -King County Departmentiof Public Health 201 Smith Tower Seattle, WA 98104, Tel: 206/296 -4787 Attn: Joe Makelerny Requirements of a food service are detailed in the Seattle or King County Food Code. For a copy of the Food Code contact your District Office. SPRINKLER DRWG. REQUIREMENT Prior to the fabrication of TENANT'S sprinkler system, TENANT's sprinkler contractor shall submit seven (7) blue line prints of shop drawings to the following for approval: Factory Mutual Insurance Great Lakes Operation - Cleveland 24950 Great Northern CorporatelCenter Suite 201 North Olmstead, OH 44070 -5319i Upon approval TENANT shall forward four (4 sets of black line (preferably) or blue line prints of th approved design bearing FACTORY MUTUAL'S approval stamp to LANDLORD'S Tenant Coordinator for LANDLORD'S approval and records as r uired in Exhibit C. CO MAC UTILITY COMPANIES & SERVICES Contact the following utility company representatives for information concerning local installation requirements, application q r fat servi ce i " b billing procedures, etc.: ELECTRIC SERVICE Puget Sound Light & Power 600 116th NE Bellevue, WA Tel: 800/962 -9498 or 206/455 -5120 GAS SERVICE Washington Natural Gas Company 815 Mercer Street Seattle, WA 98111 Service /Billing: Tel: 206/4641999 Installation: Tel: 800/999 -4964 TELEPHONE SERVICE U.S. West Communication P.O. Box 12480 Seattle, WA 98191 -0001, Tel: 206/346-8500 WATER SERVICE City of Tukwila City Hall 6200 South Center Blvd. Tukwila, WA 98188, Tel: 206/433 -1849 ROOF CONTRACTOR Any and all roof work must be completed by the LANDLORD'S approved roofing contractors: Cascade Roofing 6308 212th SW Lynnwood, WA 98036 Attn: Chris Smith, Tel: 206/464 -0441 CONTACT INFORMATION TENANT �p i �� s� varsons Fil I ADD AtS �lA.rl'1: Ps AD EXPANSION: Brills Roofing 500 Grade Street Kelso, WA 98624, Tel: 206/577 -0585 STRUCTURAL FLOOR ENGINEER Andersen Bjornstad Kane Jacobs • Inc. 800 Fifth Avenue Suite 3800 Seattle, WA 98104-3103 Tel: 206/340-2255 Fax: 206/340 -2266 SPRINKLER CONTRACTOR Crown Fire Protection (formerly Able Fire) 4932 Pioneer Road Bothell, WA 98012, Tel: 481.7669 PRECONSTRUCTION MEETING A minimum of five (5) days prior to starting construction, the CONTRACTOR shall contact the SHOPPING CENTER OFFICE to arrange a Preconstruction Meeting. Attendees should include at least the GENERAL CONTRACTOR, Superintendent and major Sub - contractors to be used in the construction. At the Preconstruction Meeting the GENERAL CONTRACTOR shall provide the following: • Building Permit - A copy of each of the Local and State Building permits. • Workers Compensation Certificate. • Insurance Certificate -'The Certificate of Insurance should be in the minimum amount of $2,000,000 in the aggregate, $1,000,000 each occurrence and should reflect the following as 'Additional Insureds': The Richard E. Jacobs Group, Inc. Southcenter Joint Venture JG Shopping Center Mgmt. LLC • Performance, Labor and Material Bond as required. • Sub - contractors List - setting forth the name, address and telephone numbers of Tenant's General Contractor and Sub - contractors. CONSTRUCTION DEPOSIT The CONTRACTOR will be required to provide a $1,500 company check, certified check or money order payable to: Southcenter Joint Venture Please have your Federal I.D. number ready and available. The deposit or any portion thereof may be applied by the LANDLORD as a reimbursement for materials- issued to or services performed directly for the,, CONTRACTOR, including LANDLORD's correctionn of punch list items not corrected by the CONTRACTOR (see below). The DEPOSITOR agrees such deposit or any portion thereof, without prejudice to any other remedy which LANDLORD may may be applied y e ppfied as a reimbursement to the LANDLORD for materials issued to and/or for services performed directly for TENANT'S CONTRACTOR (which services may include the correction of punch list items and /or for the repair/ replacement of property damaged by TENANT'S CONTRACTOR). The deposit or any then remaining balance thereof (less a 15% administration fee) will be retumed to the DEPOSITOR, without interest, within thirty (30) days after the completion of TENANT'S construction obligations as required in the LEASE. ON -SITE DOCUMENTATION The CONTRACTOR will keep the following documents on -site during construction: • Working drawings. The GENERAL CONTRACTOR will build from ONE set of drawings incorporating LANDLORD'S approval comments into the BUILDING DEPARTMENT STAMPED APPROVED SET. This set of drawings will be the primary working drawings and displayed at all times during construction. • A complete set of Typical Tenant Drawings and a net of working drawings bearing LANDLORD'S stamp of approval. • A copy of the Letter of Authorization for Access (issued by mall representative at Pre - construction Meeting.) • LANDLORD'S Construction Manual issued to CONTRACTOR at the Preconstruction Meeting. TENANT'S ARCHITECT roll i u.frur r�Aj ►1 •urid CONSTRUCTION REQUIREMENTS The following Rules govern construction on LANDLORD'S property. All references to "CONTRACTOR" shall mean the GENERAL CONTRACTOR or the TENANT if acting as its own contractor. All references to LANDLORD may equally mean the MALL REPRESENTATIVE at the shopping center, if appropriate. ASBESTOS MATERIALS In the event TENANT'S construction encounters any asbestos containing materials (ACM), TENANT shall immediately cease construction for that part of the Work which may disturb the ACM and contact LANDLORD'S Representative at the Shopping Center to resolve how to proceed. The installation of any materials that contain asbestos is strictly prohibited. EXISTING CONDITIONS It shall be TENANT'S responsibility to verify all existing construction and equipment and subject to LANDLORD'S written approval to upgrade or replace same to comply with the more stringent of: 1) goveming building codes, 2) the Federal Occupational Safety and Health Act (OSHA) and regulations promulgated thereunder, 3) all laws, ordinances and regulations of applicable State, City and Local health departments and nudity com,,a „ices 4) the requirements of LANDLORD'S fire are : casualty insurer, or 5) the provisions of the lease. All costs shall be at TENANT'S expense. PROTECTION OF PROPERTY The CONTRACTOR shall be responsible for protecting the LANDLORD'S and any other party's property from damage. Use of fuel operated engines inside the Mall and /or space will not be permitted. FIRE EXTINGUISHERS The CONTRACTOR shall provide adequate fire extinguishers within the premises, tagged for date of inspection, while under construction. SITE ACCESS & PARKING Specific areas will be designated by the LANDLORD for parking. The CONTRACTOR shall be responsible to ensure that all construction employees working in the premises use the designated parking areas. There will be no construction trailers allowed on the property. Parking will not be permitted in any of the driveways, fire lanes and truck docks except for temporary loading and unloading, as approved by the LANDLORD. DELIVERY OF MATERIALS The CONTRACTOR shall be responsible to coordinate all material deliveries to the premises, whether for construction, fixturing or merchandising. All deliveries shall be made through the rear door of the premises either via the adjacent service corridor or truck dock area. Contact the LANDLORD prior to the delivery of materials and equipment which are too large to enter through the rear door of the Premises. Any such items are to be delivered during NON-Shopping in 9 Center hours. Where there is no rear door to access space, all deliveries, trash removal, etc., must be coordinated before or after Mall operating hours, according to LANDLORD'S direction. NO exceptions. WORK AREA & STORAGE The CONTRACTOR'S work area will be restricted to the Tenant's leased premises. Service and fire corridors and truck docks shall be kept dear of all materials, equipment, debris and trash at all times. SECURITY & AFTER HOURS WORK The CONTRACTOR must receive the prior permission of the LANDLORD for work after normal working hours. LANDLORD INSPECTIONS The Tenant's construction work will be observed periodically by the LANDLORD to verify that the work is being constructed as set forth in the Tenant's Lease, Tenant Manual, Typical Tenant Drawings, Landlord approved Tenant Drawings and LANDLORD'S Construction Manual. SAFETY The CONTRACTOR shall be responsible to ensure that all work is performed in accordance with O.S.H.A. standards. The LANDLORD may, without any liability therefore, stop work that is in violation of O.S.H.A. standards or which may, in the Landlord's opinion, cause injury or harm to persons or property. CONTRACTOR must obtain a written permit from the Mall office prior to any "hot” work (ex: welding, solder- ing, torch -work, etc.). It shall be the duty and responsi- bility of the CONTRACTOR performing any cutting or TENANT'S ENGINEER 2AnlJ tint FIRM CONTAJr �i twry �tJ CT Om 3 At.FiR !AND . welding to comply with the safety provisions of the National Fire Protection Association's National Fire Codes pertaining to such work and the CONTRAC- TOR shall be responsible for all damages resulting from a failure to so comply. TEMPORARY POWER Temporary electric power will be made accessible for those Tenants where permanent power is trot yetavatlable. Where permanent power is available, it is tte;esponstfrty of the CONTRACTOR to provide the necessary equipment to supply the electrical power needed for construction. Permanent power should be ascertained as soon as possible. TEMPORARY WATER Contact the LANDLORD for coordination of temporary water service. UTILITY CHANGEOVER CONTRACTOR shall be responsible for changeover of utilities to CONTRACTOR and /or TENANTAccount as soon as possible. TEMPORARY TOILET It will be the responsibility of the CONTRACTOR to provide adequate toilet facilities for all employees working within the premises. The shopping center toilet facilities will not be available for contractors use unless specifically authorized by the LANDLORD. The location fora temporary portable type toilet facility must be approved by the LANDLORD prior to its placement. TEMPORARY BARRICADE Prior to beginning any construction, the CONTRACTOR shall ensure, if required by the LANDLORD, that a temporary barricade is installed at the storefront (see Shopping Center Manager for barricade drawings and details). Where a barricade has been erected by LANDLORD using pre - formed panels, the LANDLORD shall extend the barricade past the lease line to accommodate the storefront work. The barricade shall not be extended until storefront work actually begins, shat.: not unreasonably obstruct mall traffic, and shalt not be more than four feet (4') past the storefront lease line. All barricades shall be extended or constructed during the non - operating hours of the shopping center. No barricades shall be removed or dismantled without express written consent of the LANDLORD. Any barricade removed without prior consent will be reconstructed by the LANDLORD at the CONTRACTOR'S expense. CONSTRUCTION SIGNAGE T! , CONTRACTOR is not allowed to post any company name or sign on the temporary barricade. The CONTRACTOR shall post all signage as required by mall representative for public safety or genera warring. BELOW GRADE CONSTRUCTION Prior to beginning any below grade construction and under slab confined spaces the Contractor must • Prior to Locating Floor Penetrations, Tenant's Contractor must secure LANDLORD'S structural floor engineer's approval, see address this sheet • Meet hazardous confined space requirements. • Inform LANDLORD of the work to be undertaken and receive approval of same. • Submit ALL construction materials proposed for under slab installation to LANDLORD'S representative for approval. Once the approvals have been received and under slab construction commences the CONTRACTOR must photograph the installation in detail, both in progress and once completed, and submit copies of all photographs to LANDLORD. Any Below Grade construction must be inspected by LANDLORD prior to backfilling. CONCRETE Concrete must be saw -cut or core - drilled (no jack - hammering or breaking of concrete is permitted). Secure structural floor engineer's approval prior to reforming all floor work. Prior approval must be obtained from LANDLORD prior to penetrating any structural or structurally reinforced concrete. SPRAY PAINTING Spraying of finishes or paint must only be done if Mall HVAC and adjacent Tenant HVAC systems are either shut down or protected to avoid contamination. MALL CONTACT NAME Southcenter Mall INTERRUPTION OF UTILITIES The CONTRACTOR must receive the LANDLORD'S approval at least throe (3) days prior Warty modification to utility senices that may temporarily interrupt such service to outer tenants or the shopping center. NOISY CONSTRUCTION The LANDLORD has established working hours when the ccifracfor may perform "noisy" construction (le. saw Ming, core drilling, "Hilt?' type fastener guns, etc.).;ontact the LANDLORD for restricted hours. LANILORD reserves the sole right to request that CONTRACTOR reschedule any activities deemed disruptive taestricted hours. TRASH IEMOVAL & DUMPSTERS Trash Remrral -Ali trash will be confined to the premises and removed at the end of each day by the CONTRAClR. Any trash found in the service corridors, adjacent terxnt units, and /or other public areas will be removed brfhe LANDLORD and deducted from the CONTRAC OR'S deposit or billed to the TENANT. The locatiorof the CONTRACTOR'S dumpster will be determined ty the LANDLORD. LANDLORDS dunpsters and/or compactors are not to be used ty CONTRACTOR SPRINKER DRAIN -DOWN The CONTFACTOR sha{f saek the LANDLORD'S prior ap fuow at least two (2) days in advance of needing to easy the shopping center sprinkler system. No shopping center sprinker system will be left drained ovenxjht All systems sill be Barged and operational when the CONTRACTOR leaves for the night A$75 fee will be charged fa lima the LANDLORD'S sprinkler system is drained orshut down to accommodate connection and testing requirements. ROOF & BUILDING MODIFICATIONS The CONTRACTOR w8 riot be allowed to penetrate the roof or adjus or ruddy the LANDLORD'S sprinkler system, rectum, Mites, structure, equipment or facilities without the LANDLORB'S express written consent and will be donesy the LANDLORD'S original contractor (or LANDLORD'S designee) at the CONTRACTOR'S expense. OPERATING WHILE REMODELING hi addition to my prior stated reqiirements, the following rules apply to dares remaining open during remodeling. PRECOPSTRUCTION MEETING For stores rnnaining open during construction, The Store Manager must be present at the Preconstruction Meeting to dscuss plans for the remodel, time span of remodel anc related safety issues. BARRICADE The CONTRACTOR will be required to schedule the construction n and provide a barricade � phasing plan indicatig where the barricade will be placed. SECURITY & AFTER HOURS WORK The CONTRACTOR must receive prior permission of the LANDLCRD for work after normal working hours. In addition, the Store Manager and the CONTRACTOR waist prepare for and indicate whether a Security Officer or other service is needed. The LANDLORD will not be responsible for the security of the CONTRACTOR'S or the TENANT'S property. SAFETY In addition to the O.S.HA safety standards referenced previously. the Store Manager and CONTRACTOR must observe the following: • Provide a minimum of a four foot (4') barricade around all construction areas. • Apply plastic sheeting from the barricade up to the ceiling so as to minimize dust and related damage to merchandise, customers and the public mall areas. • Verify that all workman's tools, ladders. and loose construction supplies are out of the customers, and specifically, children's reach. • Verify that any overhead dangling light fixtures, conduits, etc. are well within the confines of the barricaded and plastic sheeted areas. • Verify that the store has down -sized its stock properly no as to remain open for business and still accommodate dear fire exits through both the rear and the front of the store. • if there is any storefront remodeling required, the CONTRACTOR will be required to erect a barricade per the above details. TENANT COORDINATOR Tel: 440/808- The Richard E. Jacobs Group, Inc. OPENING REQUIREMENTS • Certificate of Occupancy: The CONTRACTOR shall provide the LANDLORD with a copy of the Occupancy Permit. • Certified Tenant Air Balance Report • Punch List: Upon completion of construction and PRIOR TO opening, the CONTRACTOR shall request that the LANDLORD conduct a final observation and compile a punch list The premises will be allowed to open for business only after the LANDLORD has received a copy of the Occupancy Permit and the punch list items have been satisfactorily completed. LIEN WAIVERS & AFFIDAVITS The CONTRACTOR will be required to submit the following items at the end of the construction (forms are available from the LANDLORD): • An original notarized "General Contractor's Affidavit and Final Waiver of Lien ". • The original signed and notarized "Subcontractor's Affidavit and Waiver of Lien" for each contractor. nITV RECEIVED I ND n,w SOUTHCENTER SEATTLE, WASHINGTON TYPICAL TENANT GUIDELINES TTG -01 r4. ? .UNIT NUMBER T14E PI GtuKe "tofu, DBA THIS SHEET MUST BE 1 C _ N _ LUDED AS _ PART O F TENANT'S SUBMITTAL TO THE LANDLORD, LOCAL AUTHORITIES HAVING JURISDICTION AND BIDDING CONTRACTORS NMI NNW The Richard E Jacobs Group DRAWING SUBMISSION & REVIEW CHECKLIST TENANT'S SUBMISSION CHECKLIST TENANT'S drawing submission must include four (4) sets of black line (preferably) or blue line prints. PRELIMINARY CONCEPT: WORKING DRAWINGS: • Storefront Elevation (with sign) Working Drawings must be • Storefront Section(s) submitted in the following order: • Details at Neutral Pier(s) • LANDLORD'S TTG -01 Sheet • Details at LANDLORD'S Soffit • Architectural • Floor Plan • Electrical • Reflected Ceiling Plan • LANDLORD'S TTE Sheet(s) • Interior Elevations • Plumbing • Longitudinal Section • HVAC • Material Sample Board • LANDLORD'S TTM Sheet(s) • Photo of Similar Store • (other drawings) LANDLORD'S REVIEW CHECKLIST APPROVED APPROVED REVISE & DRAWING FOR CONSTRUCTION (INCLUDE WITH RESUBMIT RESUBMISSION) PRELIMINARY ARCHITECTURAL ELECTRICAL - PLUMBING HVAC NOTES: RESUBMISSIONS: TENANT shall resubmit drawings within ten 10 days. All re u mis g O ions shall be y s b s COMPLETE sets with four (4) sets of black line.(preferably) or blue line prints. SIGN: This review does not include final approval of TENANT'S sign. Prior to fabrication & installation of TENANT'S sign, TENANT'S sign fabricator (sign company) shall submit three (3) sets of shop drawings to LANDLORD for approval. CHANGES: Once approved by LANDLORD, no changes shall be made in TENANT'S Drawings except upon the PRIOR written consent of the LANDLORD. AS- BUILTS: Within thirty (30) days after the opening of the Premises, TENANT shall submit a complete set of as -built drawings to LANDLORD. I THIS AREA FOR LANDLORD USE ONLY... • NOTE: DRAWINGS WITH II! IN THE LOWER RIGHT HAND CORNER ARE APPROVED BY LANDLORD LANDLORD'S approval of TENANT'S Drawings is contingent upon TENANT'S compliance with LANDLORD'S comments and shall not be construed so as to hold LANDLORD liable for either the architectural and engi- neering design of the Premises or the accuracy of the information contained in TENANT'S Drawings. Should any conflict arise between any of TENANT'S Drawings and the Lease, the applicable portion(s) of the Lease shall be determinative. LANDLORD'S approval of TENANT'S Drawings will in no way alter, amend or waive the requirements or criteria of the Lease. I BUILDING PERMIT INFORMATION In order to obtain a Building Permit from the City of Seattle, the following procedure will be required: Applications for building permits are submitted to the Department of Community Development. Upon receipt, plans are routed to the City's plan checker and if appropriate to the Fire Department, Planning Division, and Public Works Department. The following documents are required: 1. A completed building permit application form. 2. Two (2) copies of working drawings, to include, but not limited to, the following: a. Site plan b. Overall building plan c. Floor plan of TENANT space d. Construction details 3. Plan Review Fee to be paid at time of application. City of Tukwila Building Division 6300 Southcenter Blvd. Tukwila, WA 98188, Tel: 206/431.3670 FOOD & RESTAURANTS Food handling or restaurant type TENANTS shall submit two (2) sets of plans to: Seattle -King County Departmentiof Public Health 201 Smith Tower Seattle, WA 98104, Tel: 206/296 -4787 Attn: Joe Makelerny Requirements of a food service are detailed in the Seattle or King County Food Code. For a copy of the Food Code contact your District Office. SPRINKLER DRWG. REQUIREMENT Prior to the fabrication of TENANT'S sprinkler system, TENANT's sprinkler contractor shall submit seven (7) blue line prints of shop drawings to the following for approval: Factory Mutual Insurance Great Lakes Operation - Cleveland 24950 Great Northern CorporatelCenter Suite 201 North Olmstead, OH 44070 -5319i Upon approval TENANT shall forward four (4 sets of black line (preferably) or blue line prints of th approved design bearing FACTORY MUTUAL'S approval stamp to LANDLORD'S Tenant Coordinator for LANDLORD'S approval and records as r uired in Exhibit C. CO MAC UTILITY COMPANIES & SERVICES Contact the following utility company representatives for information concerning local installation requirements, application q r fat servi ce i " b billing procedures, etc.: ELECTRIC SERVICE Puget Sound Light & Power 600 116th NE Bellevue, WA Tel: 800/962 -9498 or 206/455 -5120 GAS SERVICE Washington Natural Gas Company 815 Mercer Street Seattle, WA 98111 Service /Billing: Tel: 206/4641999 Installation: Tel: 800/999 -4964 TELEPHONE SERVICE U.S. West Communication P.O. Box 12480 Seattle, WA 98191 -0001, Tel: 206/346-8500 WATER SERVICE City of Tukwila City Hall 6200 South Center Blvd. Tukwila, WA 98188, Tel: 206/433 -1849 ROOF CONTRACTOR Any and all roof work must be completed by the LANDLORD'S approved roofing contractors: Cascade Roofing 6308 212th SW Lynnwood, WA 98036 Attn: Chris Smith, Tel: 206/464 -0441 CONTACT INFORMATION TENANT �p i �� s� varsons Fil I ADD AtS �lA.rl'1: Ps AD EXPANSION: Brills Roofing 500 Grade Street Kelso, WA 98624, Tel: 206/577 -0585 STRUCTURAL FLOOR ENGINEER Andersen Bjornstad Kane Jacobs • Inc. 800 Fifth Avenue Suite 3800 Seattle, WA 98104-3103 Tel: 206/340-2255 Fax: 206/340 -2266 SPRINKLER CONTRACTOR Crown Fire Protection (formerly Able Fire) 4932 Pioneer Road Bothell, WA 98012, Tel: 481.7669 PRECONSTRUCTION MEETING A minimum of five (5) days prior to starting construction, the CONTRACTOR shall contact the SHOPPING CENTER OFFICE to arrange a Preconstruction Meeting. Attendees should include at least the GENERAL CONTRACTOR, Superintendent and major Sub - contractors to be used in the construction. At the Preconstruction Meeting the GENERAL CONTRACTOR shall provide the following: • Building Permit - A copy of each of the Local and State Building permits. • Workers Compensation Certificate. • Insurance Certificate -'The Certificate of Insurance should be in the minimum amount of $2,000,000 in the aggregate, $1,000,000 each occurrence and should reflect the following as 'Additional Insureds': The Richard E. Jacobs Group, Inc. Southcenter Joint Venture JG Shopping Center Mgmt. LLC • Performance, Labor and Material Bond as required. • Sub - contractors List - setting forth the name, address and telephone numbers of Tenant's General Contractor and Sub - contractors. CONSTRUCTION DEPOSIT The CONTRACTOR will be required to provide a $1,500 company check, certified check or money order payable to: Southcenter Joint Venture Please have your Federal I.D. number ready and available. The deposit or any portion thereof may be applied by the LANDLORD as a reimbursement for materials- issued to or services performed directly for the,, CONTRACTOR, including LANDLORD's correctionn of punch list items not corrected by the CONTRACTOR (see below). The DEPOSITOR agrees such deposit or any portion thereof, without prejudice to any other remedy which LANDLORD may may be applied y e ppfied as a reimbursement to the LANDLORD for materials issued to and/or for services performed directly for TENANT'S CONTRACTOR (which services may include the correction of punch list items and /or for the repair/ replacement of property damaged by TENANT'S CONTRACTOR). The deposit or any then remaining balance thereof (less a 15% administration fee) will be retumed to the DEPOSITOR, without interest, within thirty (30) days after the completion of TENANT'S construction obligations as required in the LEASE. ON -SITE DOCUMENTATION The CONTRACTOR will keep the following documents on -site during construction: • Working drawings. The GENERAL CONTRACTOR will build from ONE set of drawings incorporating LANDLORD'S approval comments into the BUILDING DEPARTMENT STAMPED APPROVED SET. This set of drawings will be the primary working drawings and displayed at all times during construction. • A complete set of Typical Tenant Drawings and a net of working drawings bearing LANDLORD'S stamp of approval. • A copy of the Letter of Authorization for Access (issued by mall representative at Pre - construction Meeting.) • LANDLORD'S Construction Manual issued to CONTRACTOR at the Preconstruction Meeting. TENANT'S ARCHITECT roll i u.frur r�Aj ►1 •urid CONSTRUCTION REQUIREMENTS The following Rules govern construction on LANDLORD'S property. All references to "CONTRACTOR" shall mean the GENERAL CONTRACTOR or the TENANT if acting as its own contractor. All references to LANDLORD may equally mean the MALL REPRESENTATIVE at the shopping center, if appropriate. ASBESTOS MATERIALS In the event TENANT'S construction encounters any asbestos containing materials (ACM), TENANT shall immediately cease construction for that part of the Work which may disturb the ACM and contact LANDLORD'S Representative at the Shopping Center to resolve how to proceed. The installation of any materials that contain asbestos is strictly prohibited. EXISTING CONDITIONS It shall be TENANT'S responsibility to verify all existing construction and equipment and subject to LANDLORD'S written approval to upgrade or replace same to comply with the more stringent of: 1) goveming building codes, 2) the Federal Occupational Safety and Health Act (OSHA) and regulations promulgated thereunder, 3) all laws, ordinances and regulations of applicable State, City and Local health departments and nudity com,,a „ices 4) the requirements of LANDLORD'S fire are : casualty insurer, or 5) the provisions of the lease. All costs shall be at TENANT'S expense. PROTECTION OF PROPERTY The CONTRACTOR shall be responsible for protecting the LANDLORD'S and any other party's property from damage. Use of fuel operated engines inside the Mall and /or space will not be permitted. FIRE EXTINGUISHERS The CONTRACTOR shall provide adequate fire extinguishers within the premises, tagged for date of inspection, while under construction. SITE ACCESS & PARKING Specific areas will be designated by the LANDLORD for parking. The CONTRACTOR shall be responsible to ensure that all construction employees working in the premises use the designated parking areas. There will be no construction trailers allowed on the property. Parking will not be permitted in any of the driveways, fire lanes and truck docks except for temporary loading and unloading, as approved by the LANDLORD. DELIVERY OF MATERIALS The CONTRACTOR shall be responsible to coordinate all material deliveries to the premises, whether for construction, fixturing or merchandising. All deliveries shall be made through the rear door of the premises either via the adjacent service corridor or truck dock area. Contact the LANDLORD prior to the delivery of materials and equipment which are too large to enter through the rear door of the Premises. Any such items are to be delivered during NON-Shopping in 9 Center hours. Where there is no rear door to access space, all deliveries, trash removal, etc., must be coordinated before or after Mall operating hours, according to LANDLORD'S direction. NO exceptions. WORK AREA & STORAGE The CONTRACTOR'S work area will be restricted to the Tenant's leased premises. Service and fire corridors and truck docks shall be kept dear of all materials, equipment, debris and trash at all times. SECURITY & AFTER HOURS WORK The CONTRACTOR must receive the prior permission of the LANDLORD for work after normal working hours. LANDLORD INSPECTIONS The Tenant's construction work will be observed periodically by the LANDLORD to verify that the work is being constructed as set forth in the Tenant's Lease, Tenant Manual, Typical Tenant Drawings, Landlord approved Tenant Drawings and LANDLORD'S Construction Manual. SAFETY The CONTRACTOR shall be responsible to ensure that all work is performed in accordance with O.S.H.A. standards. The LANDLORD may, without any liability therefore, stop work that is in violation of O.S.H.A. standards or which may, in the Landlord's opinion, cause injury or harm to persons or property. CONTRACTOR must obtain a written permit from the Mall office prior to any "hot” work (ex: welding, solder- ing, torch -work, etc.). It shall be the duty and responsi- bility of the CONTRACTOR performing any cutting or TENANT'S ENGINEER 2AnlJ tint FIRM CONTAJr �i twry �tJ CT Om 3 At.FiR !AND . welding to comply with the safety provisions of the National Fire Protection Association's National Fire Codes pertaining to such work and the CONTRAC- TOR shall be responsible for all damages resulting from a failure to so comply. TEMPORARY POWER Temporary electric power will be made accessible for those Tenants where permanent power is trot yetavatlable. Where permanent power is available, it is tte;esponstfrty of the CONTRACTOR to provide the necessary equipment to supply the electrical power needed for construction. Permanent power should be ascertained as soon as possible. TEMPORARY WATER Contact the LANDLORD for coordination of temporary water service. UTILITY CHANGEOVER CONTRACTOR shall be responsible for changeover of utilities to CONTRACTOR and /or TENANTAccount as soon as possible. TEMPORARY TOILET It will be the responsibility of the CONTRACTOR to provide adequate toilet facilities for all employees working within the premises. The shopping center toilet facilities will not be available for contractors use unless specifically authorized by the LANDLORD. The location fora temporary portable type toilet facility must be approved by the LANDLORD prior to its placement. TEMPORARY BARRICADE Prior to beginning any construction, the CONTRACTOR shall ensure, if required by the LANDLORD, that a temporary barricade is installed at the storefront (see Shopping Center Manager for barricade drawings and details). Where a barricade has been erected by LANDLORD using pre - formed panels, the LANDLORD shall extend the barricade past the lease line to accommodate the storefront work. The barricade shall not be extended until storefront work actually begins, shat.: not unreasonably obstruct mall traffic, and shalt not be more than four feet (4') past the storefront lease line. All barricades shall be extended or constructed during the non - operating hours of the shopping center. No barricades shall be removed or dismantled without express written consent of the LANDLORD. Any barricade removed without prior consent will be reconstructed by the LANDLORD at the CONTRACTOR'S expense. CONSTRUCTION SIGNAGE T! , CONTRACTOR is not allowed to post any company name or sign on the temporary barricade. The CONTRACTOR shall post all signage as required by mall representative for public safety or genera warring. BELOW GRADE CONSTRUCTION Prior to beginning any below grade construction and under slab confined spaces the Contractor must • Prior to Locating Floor Penetrations, Tenant's Contractor must secure LANDLORD'S structural floor engineer's approval, see address this sheet • Meet hazardous confined space requirements. • Inform LANDLORD of the work to be undertaken and receive approval of same. • Submit ALL construction materials proposed for under slab installation to LANDLORD'S representative for approval. Once the approvals have been received and under slab construction commences the CONTRACTOR must photograph the installation in detail, both in progress and once completed, and submit copies of all photographs to LANDLORD. Any Below Grade construction must be inspected by LANDLORD prior to backfilling. CONCRETE Concrete must be saw -cut or core - drilled (no jack - hammering or breaking of concrete is permitted). Secure structural floor engineer's approval prior to reforming all floor work. Prior approval must be obtained from LANDLORD prior to penetrating any structural or structurally reinforced concrete. SPRAY PAINTING Spraying of finishes or paint must only be done if Mall HVAC and adjacent Tenant HVAC systems are either shut down or protected to avoid contamination. MALL CONTACT NAME Southcenter Mall INTERRUPTION OF UTILITIES The CONTRACTOR must receive the LANDLORD'S approval at least throe (3) days prior Warty modification to utility senices that may temporarily interrupt such service to outer tenants or the shopping center. NOISY CONSTRUCTION The LANDLORD has established working hours when the ccifracfor may perform "noisy" construction (le. saw Ming, core drilling, "Hilt?' type fastener guns, etc.).;ontact the LANDLORD for restricted hours. LANILORD reserves the sole right to request that CONTRACTOR reschedule any activities deemed disruptive taestricted hours. TRASH IEMOVAL & DUMPSTERS Trash Remrral -Ali trash will be confined to the premises and removed at the end of each day by the CONTRAClR. Any trash found in the service corridors, adjacent terxnt units, and /or other public areas will be removed brfhe LANDLORD and deducted from the CONTRAC OR'S deposit or billed to the TENANT. The locatiorof the CONTRACTOR'S dumpster will be determined ty the LANDLORD. LANDLORDS dunpsters and/or compactors are not to be used ty CONTRACTOR SPRINKER DRAIN -DOWN The CONTFACTOR sha{f saek the LANDLORD'S prior ap fuow at least two (2) days in advance of needing to easy the shopping center sprinkler system. No shopping center sprinker system will be left drained ovenxjht All systems sill be Barged and operational when the CONTRACTOR leaves for the night A$75 fee will be charged fa lima the LANDLORD'S sprinkler system is drained orshut down to accommodate connection and testing requirements. ROOF & BUILDING MODIFICATIONS The CONTRACTOR w8 riot be allowed to penetrate the roof or adjus or ruddy the LANDLORD'S sprinkler system, rectum, Mites, structure, equipment or facilities without the LANDLORB'S express written consent and will be donesy the LANDLORD'S original contractor (or LANDLORD'S designee) at the CONTRACTOR'S expense. OPERATING WHILE REMODELING hi addition to my prior stated reqiirements, the following rules apply to dares remaining open during remodeling. PRECOPSTRUCTION MEETING For stores rnnaining open during construction, The Store Manager must be present at the Preconstruction Meeting to dscuss plans for the remodel, time span of remodel anc related safety issues. BARRICADE The CONTRACTOR will be required to schedule the construction n and provide a barricade � phasing plan indicatig where the barricade will be placed. SECURITY & AFTER HOURS WORK The CONTRACTOR must receive prior permission of the LANDLCRD for work after normal working hours. In addition, the Store Manager and the CONTRACTOR waist prepare for and indicate whether a Security Officer or other service is needed. The LANDLORD will not be responsible for the security of the CONTRACTOR'S or the TENANT'S property. SAFETY In addition to the O.S.HA safety standards referenced previously. the Store Manager and CONTRACTOR must observe the following: • Provide a minimum of a four foot (4') barricade around all construction areas. • Apply plastic sheeting from the barricade up to the ceiling so as to minimize dust and related damage to merchandise, customers and the public mall areas. • Verify that all workman's tools, ladders. and loose construction supplies are out of the customers, and specifically, children's reach. • Verify that any overhead dangling light fixtures, conduits, etc. are well within the confines of the barricaded and plastic sheeted areas. • Verify that the store has down -sized its stock properly no as to remain open for business and still accommodate dear fire exits through both the rear and the front of the store. • if there is any storefront remodeling required, the CONTRACTOR will be required to erect a barricade per the above details. TENANT COORDINATOR Tel: 440/808- The Richard E. Jacobs Group, Inc. OPENING REQUIREMENTS • Certificate of Occupancy: The CONTRACTOR shall provide the LANDLORD with a copy of the Occupancy Permit. • Certified Tenant Air Balance Report • Punch List: Upon completion of construction and PRIOR TO opening, the CONTRACTOR shall request that the LANDLORD conduct a final observation and compile a punch list The premises will be allowed to open for business only after the LANDLORD has received a copy of the Occupancy Permit and the punch list items have been satisfactorily completed. LIEN WAIVERS & AFFIDAVITS The CONTRACTOR will be required to submit the following items at the end of the construction (forms are available from the LANDLORD): • An original notarized "General Contractor's Affidavit and Final Waiver of Lien ". • The original signed and notarized "Subcontractor's Affidavit and Waiver of Lien" for each contractor. nITV RECEIVED I ND n,w SOUTHCENTER SEATTLE, WASHINGTON TYPICAL TENANT GUIDELINES TTG -01 r4. ? .UNIT NUMBER T14E PI GtuKe "tofu, DBA THIS SHEET MUST BE 1 C _ N _ LUDED AS _ PART O F TENANT'S SUBMITTAL TO THE LANDLORD, LOCAL AUTHORITIES HAVING JURISDICTION AND BIDDING CONTRACTORS NMI NNW The Richard E Jacobs Group