HomeMy WebLinkAboutPermit M2000-223 - COSTCOM2000-223 Costco 1160 Saxon Dr EX !RED APR 1 8 2002, City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M2000 -223 Type: B-MECH Category: NRES Address: 1160 SAXON DR Location: Parcel #: 252304 -9063 Contractor License No: HUSSMCk134JZ MECHANICAL PERMIT 'L tatus : ISSUED Issued: 09/27/2000 Expires: 03/26/2001 TENANT COSTCO WHOLESALE 1160 SAXON DR, TUKWILA WA 98138 OWNER SADE PAUL +ELEANOR 585 POINT SAN PEDRO RD, SAN RAFAEL CA 94901 CONTACT DON JARRETT Phone: 206 -763 -9050 7272 1 AV S, SEATTLE WA 98108 CONTRACTOR HUSSMANN CORPORATION Phone: 206 763 -9050 7272 FIRST AV S, SEATTLE WA 981080267 REPLACE EXISTING FREEZER /COOLER WITH DOORS AND COILS. UMC Edition: 1997 Permit Cente thortzed Signature Date Valuation: Total Permit Fee: Phone: 4 * k h - k * k * • k * * k * * * •k * # •k - k it # * * k k k 4 k k * * k k k k k •k k : 4 * k k k * k k •k k k * * k k * • k * * k * k * k k * k k * k * * * Permit Description: (206) 431 -3670 44,135.00 69.31 . kk*• kk****** k **#41k# kkkk k* 4k* kk*k* Akk*k**•* 4• A4 *kk4 *4*k** *4* **#*k# * **k* *k.kkk# I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing thin work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local 1 laws regulating construction or the performance of work. 1 am authorized to sign for and obtain this building permit, till9nAturoadUrePrAy „-e-It2..,t6ecifid Print N d MO : - _ .��. (.'.. ,2 4/ _ .L.e ,Lact it 1 .... T i l e Of J0)1S- ,(_..Q 61�: �. 0 - 6/ T h i s permit shall become n u l l and void if the work i nor commenced within 180 days from the date of issuance, or if the work is suspended or .abandoned for .t period of 180 days from the last inspection. CITY OF TUKWILA Permit No: M2000 -223. Address 1160 SAXON DR: Su1te: Tenant: COSTCO WHOLESALE : Type :.B -MECH Par:pe1 1: 252304-9063 ** * * *•k* * * * ** *** 1 ** k * * * * ** k ** A* ** *•kit ** k*** * * *•k **; *'k* * *•k* k *-kic *** ** A ** * ** k# Permit Conditions: 1. : E l ectr i ca 1 permits shall be obtained through the Washington State Division of Labor and_ : In,dustr.ies and all electrical work will be inspected - bye : ti at agency (248 -6630) , BTU MAKI.MUM `ALLOWIO PCR 1991 WASHINGTON STATE ENERGY CODE. do changes wi 11 be maade to tine p 1 ens unless approved try the Engineer and ;the f ukw l l e Bu i`1 d i rig Division ; All perrniti, "insp`e.ct records, end approved p ` ans he11 be avea i l ab le 'art; tie .job s i.te' t rl or to thy"' start' of any, crri . `struct y 6 : : these ' do,curents: anre to be maintained arid a.001- ab l e e urtit i 1 fine) insPecttonAtOprOval is granted; All o`e nstruct 1 on to be done i n conformance with approved p l aane , nd'. requ i r�emen ts; cif the Uniform Building Code A1,997 (1.997 Edit )On) ¢ :as` emendod, :Ura i farm Mechaan i ca l Code (1997 Edition. Oland Wabash i ngton:' S taco Energy., Code 11997 Edition). V 1 d1 Ly`�.of`' Permit . , The issuance of e . permit or ap asa 1 pro.iel' u f p 1 adinS, acpec i :i ca t ions, end cornputwat i.ons� shall not be cony st•.v'uad to be a,pormit for, 'ar a n ltpp of, any viol.atl of °Qtly rof : ° t.,he prov l s i ons 01'; the bu i 1;d i ng code or of tiny at,her ordinance .of the jurisdictions. .No permit pren5umi.ng t g iv`y° aau'tihar i ty to, .v 1 o l ante or .caance l ` the p r o v i s i o n s of th i s co;1 .` sha 1 l be. va 1 i d, 14anufaact;u'rors : inste) hitfon irnst,ructiuns required on sit for £ he ` bU 1. i,d i ng inspectors review. Y i Status: ISSUED Applied: 09/18/2000 Issued: 09/27/2000 Project Name/Tenant: --` j / / City State/Zip: Value of echa i _al Equipment: Tax Parcel NUmbe : Site Address : Property Owner: ) 9 . y Is e J _eja.23.11.4 -�-` 174).. 141 tft be Address: City /State /Zip: � � 1 � t 4 , Phone: ( ) Street Address: City State/Zip: Fax #: ( ) Contractor: ` h1 GLI'1, n (- '- Phone: ( ) Street Address: E S C State/Zirr -( Fax #: ( ) Contact Person: ,./�. c� A ,1 Gt.r r� _, t / auree4 . Phone: (� 3 (fl) '9.0S-7) � '9 Street Address: ` ,,e _ City State/Zip: Fax #: (dab) 7 (D S 3 3 BUILDING. OWNER OR AUTHORIZED AGENT: Signature: Date: Print name: y�/��� ux ' b Phone: cot 1 7b a c p 4 Fax I: Le ) 9 . y Is e J _eja.23.11.4 -�-` 174).. 141 tft be Address: City /State /Zip: � � 1 � t 4 , Mechanical Permit Application Description of work to be done (please be specific): CITY Of T UKWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO RE FILLED OUT BY APPLICANT) f L e..„oatr'r . _�,u i t CD der s CO► FO' STAFF USE ONLY Project Number: Permit Number. 2QDO-L7 Current copy of Washington State Department of Labor and Industries Valid Contractor's License, If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H•4, "Affidavit In Lieu of Contractor Registration ", Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/eniineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal, I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review , Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: 11 /2/99 meth peemltdoc Date application expires: t A 0--0 2 f W 0,3 00 0W W x � d Z 8F2 gg u . Z� Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements NOTE: Water heaters and vents are included In the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Submittal Requircem ent% New Sin to Famil Residence Heat loss calculations or Form H -6. Equipment specifications. Chanue•out or replacement of *Astir, R mechanical equipment Narrative of work to be done includin modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is In safe condition. NOTE: Water heaters and vents are Included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced, Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening _ Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CEM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). _ . Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements NOTE: Water heaters and vents are included In the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Submittal Requircem ent% New Sin to Famil Residence Heat loss calculations or Form H -6. Equipment specifications. Chanue•out or replacement of *Astir, R mechanical equipment Narrative of work to be done includin modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is In safe condition. NOTE: Water heaters and vents are Included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced, *44dr 4** * ***** * **4**44 4 4*4 * **441,44*{*k*4k44 * 44***4440 4* CI IY OF TUKWXLA WA 2..0 TRANSMIT * *4 *4 ***4444* *+4**4444 **04 A % . *I * k 44*4 # * *f *Alt***A*4 *4 * ** TRANSMIT Numbers R1U00365 Amounts 69.31 09/2'7/00 1$ :1' PayMent Method: CASH Not ut; iun: MAUR EN CW 1LINA 'nits TLII Itt a a J . r • 1 1 . . ••••. It a • .41.* t r .. +" .4 + t .. J , A 1+• .J x • ..t s a. .. .. " "• • 1 .• NO . • I s 1 w 4 , , , • . , • . . . . . . . . . t t a .... w • 1 .. .. t . • 1 J• 11 'Permit NO: M2000-223 1 vpe: 11'IMECH I'aruo1 No 252304-9063 Addres s* 1160 SAXON OR Payment Account Odds 000/345 030 0(30x'322.100 MECHANICAL I'LNMI T Total Foust 669.31 Total I (ILL nets: 13 A 1 drIek: *4 4** *4 *4 * #4 ** **44*44 I)ascr1pt Ion PLAN CHEce:K - NOIRES MECHANICAL MODUJL3 69.11 .00 **At* *d* Amount 1:3.86 35.45 •t M •, .. M a i.t •t N R •n uu .l ;i yt .a •a - Rt . t •+ .•t .1l /a 1. a. .I' a, l - I t Mt •+ Ot t. it /' O .• tM . is • . •" •. # t, t al 0. 5 t+ s. ti •t •+ 9/27 9707 TOTAL PERMIT NO.: C" WOO MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 00002 Pre - construction ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation/Indoor AQC ❑ 00610 Chimney Installation/All Types ❑ 00700 Framing ❑ 01080 Woodstove ❑ 01090 Smoke Detector Shut Off 01100 Rough -in Mechanical 01101 Mechanical Equipment/Controls ❑ 01102 Mechanical Pip/Duct insul 01105 Underground Mech Rough -in 01115 Motor Inspection 1400 Fire Final 01800 Final Mechanical 04015 Special -Smoke Control System 70 CO r 'l ty ONDiTIONS 0001 No changes to plans unless approved by Bldg Div ❑ 0014 Readily accessible access to roof mounted equipment 0016 Exposed insulation backing material 0019 All construction to be done in conformance w /approved plans ❑ 0002 Plumbing permits shall be obtained through King Co 0027 Validity of Permit 0003 Electrical permits obtained through L & 1 0036 Manufacturers installation instructions required on site "BTU maximum allowed per 1997 WA State Energy Code" 0041 Ventilation is required for all new rooms & spaces "Fuel burning appliances "Appliances, which generate.,.." "Water heater shall be anchored...." Additional Conditiq, TENANT NAME: FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (YIN) Furnace/Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor - mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP/1,750,000 BTU (qty) over 50 HP /1,750,000 BTU (qty) Air Handling Unit to 10,000 cfin (qty) over 10,000 cf}n (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator — Domestic (qty) Incinerator =- Comm /1nd (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter SS) Add'i Fees — Work w/o Permit (YIN) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'I Plan Review (hrs) Plan Reviewer: Permit Tech: Date: Date: C I Proj • . ; T e of tnspectn : .. . ss • a e ca ed: pedal instructio s: El Date want d: 1 0 r Requ ter: . 44. A :. ' ,.m P e: COMMENTS& Inspector: Date: w�r� �re�r►..�r Allinnitr $47.00 S PECTION EQUIRED. Prior to inspection; fee must be aid at 6300 Southcenter Blvd. Suite 100. Call to schedule reins ection. Receipt No; Date: Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 (206)431 -3670 yiI PERMIT NO. Corrections required prior to approval. Project: rM► ... + ' T e of l spection: I ¢, A. 4-1 (N. Address: Q h ''�"w�J Date called: tt Special instructions: Date wanted: • .. ...00 Phone: INSPECTION RECORL Retain a copy with permit INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 PERMIT NO.. (206)431 -3670 E,Approved per applicable codes. El Corrections required prior to approval COMMENTS: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Bivd Suite 100. Call to schedule reins e_„I, coon Receipt No: Date: •; �-- ., ;:': d` y:. ��;�`�5�,r3 i ��r� .: ^ki'�' .,. ,�• � s: � -., , �,r,J: r t.5.7"...7 +. cia`* yp v74 • ►tr,�.'''.:'*:a�re7•4477;•.7-77,,,f p • � ti ... ti sb +, Project Name CeAVC0 Address /Ple City of Thkwlla Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Retain current inspection schedule Needs shift inspection John W Rants, Mart Thomas P. Keefe, Are Chief Permit No. -.' Suite # Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: t �,�„ ►___ "4\ +v Hood & Duct: Halon: ...� Monitor: Pre - Fire: Permits: FINALAPP . FRM Authorized Signature T.F.D. Form F.P. 85 qS Date Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax: (206) 575.4439 April 4, 2002 Mr. Don Jarrett 7272 First Ave 8 Seattle, WA 08108 City of Tuki.vila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: Permit Application No, M2000.223 Location: Costco Wholesale 1180 Saxon Dr. Deer Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division, Per the Uniform Building Code and/or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void If the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or If the building or work authorized by such pormlt Is suspended or abandoned at any time after the work Is commenced for a period of 180 days, Based on the above, you are hereby advised to: • Coll the City Of Tukwila Permit Center at (208) 431.3870 to schedule a progress or a final inspection A progress Inspection Is Intended to determine If substantial work has been accomplished since Issuance of the permit or last inspection; or If the project should bo considered abandoned, If such determination is made, the Building Code does allow the Building Official to approve a .one-Nmo extsagon i to 180 di, Extension requests must be In writing and provide satisfactory reasons why circumstances beyond tho applicant's control have prevented action from being token, In the event you do not call for tho above inspection or request and receive an extension prior to April 18, 2002, your permit will become null and void and any further work on the project will require a now pormlt and associated fees, Thank you for your cooperation in this matter, Sincerely, I<Grthigril1) Ci e e (1 Kathryn A, Stetson Permit Technician Xc; Permit File No,M2000.223 Bob Benedicto, Acting Building Official EXPIRED APR 18 ZOOZ 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431.3670 • Fax: 206. 431.3665 .1 t. M (;' August 17, 2001 Mr. Don Jarrett 7272 1st Ave. So. Seattle, WA 98108 City of Tukwila Dear Mr. Jarrett: Department of Community Development RE: Permit Status M2000.223 Site Address: 1160 Saxon Drive Steven M. Mullei Steve Lancaster, In reviewing our current permit files, it appears that your permit for replacement of existing freezer /cooler at Costco Wholesale issued on September 27, 2000, has not received a final inspection as of the date or this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if' the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your tile and the work completed to date will be considered noncomplying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206) 431.3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter, Sincerely, 10.7t-tut, vw C . Kathryn A. Stetson Permit Technician Xe: Permit Pilo No. M2000.223 Duane Griffin, Building Official S i 1.:`t '` , rvry E,Y,Vt Wk I a- 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431.3670 • Fax: 206• DEPARTMENTS: Buildi`iVivision let AU/ 4- -ex) Public Works Complete Comments: WUNIt {fKc Wri i s PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M2000 -223 PROJECT NAME: COSTCO WHOLESALE SITE ADDRESS: 1160 SAXON DR _X,X. Original Plan Submittal .�� Response to Correction Letter # _Revision # After Permit Is Issued APPROVALS OR CORRECTIONS: (ten days) O NiaNDEIER MN A 11,Q N: Fire Prevention • Al CI .210 Structural DETERMINATION QF COMPLETENESS: (Tues., Thurs,) Incomplete ❑ TUES/THURS ROUT! C: Please Route Structural Review Required REVIEWER'S INITIALS: Approved Approved with Conditions REVIEWER'S INITIALS: C DATE: , 9- 18.2000 Response to Incomplete Letter # Planning Division Permit Coordinator II DUE DATE: 9.1'9- OOO Not Applicable El No further Review Required DATE: DATE: DUE DATE 10 -17 -2000 Not Approved (attach comments) ❑ DUE DATE Approved E Approved with Conditions E Not Approved (attach comments) ❑ REVIEWER'S INITIALS: DATE: REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST, # EXP, DATE CCO1 HUSSMC *134JZ 01/30/2001 EFFECTIVE DATE 04/09/1987 HUSSMANN CORPORATION ATTN: SANDRA DAVIS 7272 FIRST AVE 5 SEATTLE WA/ 98108 Signature ":",e Issued by DI:PAIiTMENT OF LABOR AND INDUSTRIES -USSVA.SN NALK iN RE,G,A1 Mann` ocac Acc e B.0 Sec ' ', 5 5 ,0 ' 0F L 'Le s ss ' rc ' sknel.seed Nct Less Thec 500 F Posh Not Less Thor. BOO F Self Underr,ters Lobocoto Inc. Control No. 2J77 Los Angeles ,eseecch Repo, No. 25147 0- + J 1.0 6 P 21 6— 1/2 PLYWOOD COVERED ON 5 [ SIDES WITH 51-11a7 METAL TO MATO, CASE. PRONIDED BY INSTALLER. (E) BAKI3RY COOLER —/ 200 00 FT.010 1/4 (0) 200 S2. FT. EXPANSION (E) (2) 1 SIZES 1/2 L-BRACKET PROVIDED BY INSTALLER. VARY FLAN VIEW SIPE VIEW 13 25 CLONEOFF PAW, TO BE FIELD NOTCHED FOR STORE COLUMN A5 REOUIRED. ( 0) r j (0) 000E-TCP CONX361N6 UNET — ROPCL7. DIK5SIONS: 55,4 (MARA.) NEIGHT 9G0 L55. (AM..) (EXALT LOG4TICN PETERMINED SY 0.5.) 60 xt34 (FIT DIMENSION Err ) -9° EL EI 0 5/D NCI _ sa.ATo su LB, * BY MANN. 0) 0) GALVANIZED STEEL BUMPER SIZES -MGR PRODUCE (EXISTING) 00E DELI (EXISTINS) 05E r ( ExIsTiNs) 101-000 (EXI501N6) MED -02 HOT CASE , (ExisTINs) IMI-KDE MEAT ISLAND (EXI50IN6) 02-X6E DELI ISLAND (ExIsT146) LEX/C00X 1300E00 1.A010 (EXI5TIN6) NGI PELATO (D(1501%) 5 1/2 (0) rE, (3/ 936-Z3GA 10E) 1 32'-2 I/O . GA50 OPE4IN6 (0) PRODUCE COOLER 16 b•x10 4 1/4 (E) (0) 52'5 - NPR PRODUCE AfA OF NOW, (0) ANTHONY 32 RE000-1N 00 00) NOTES a4 012o lx.1 I. GALVANIZED STEEL BUMPERS FURNISHED BY 0055MA044 AND INSTALLED 6' REFRIGERATION INSTALLATION Ca4TRACTOR. BUNFERS TO BE INSTALLED IN FRONT AND/OR 0000 00 ALL GASES. 2. PUSSIXANN TO WRAP COLUMNS IN MEAT COOLER WI0H 6ALVANIZED STEEL 70 10 A.F.F. 3. SEE ARCHITECTURALORAAINSE FOR CURBS IN AND/OR AROUND REFR160ERATED BOXES, 5. EXACT LOCATION OF'ROOFTOP UNIT TO'BE DETERMIIED BY •5 EN6INEER. 6 PENETRATION FOR REFRIGERATION LINES, CUTT1N6, PATCHINS, ANP iSEATHERPROOFING BY 6.G. WORDINATE LOCATION KITH REFRI6ERATI0N CONTRACTOR. RE) (E) (I■E''' COOLER OF.ING 2001 . 5/0 5/4 E, 0 1/2 24.4 5/0 IM1-KDE DELI (E) MEAT COOLER EQUIPMENT SCHEDULE (6) ANTHONY 32,44° REACH-IN DOORS (N) / - 4 1 USED EXIST. EXISTINS MODIFIED DOSTINS RELOCATED 1 DUSTING COOLIR/FREEZER MU. NEW GOOLJER/FPEEL. NALL (0) 9 xM VP FACTO* FLOOR .46NEF REWIRED FOR 5LIDIN6 000R. v Ip PP v PP PP PP PP PP PP I MI -KDE T 12 02-06E O0)L1 12 C2-XPE LL (E4' SA.E5 (VERIFY) (0) (0) MEAT PREP. 1,191 50. FT. (E) (EXISTIN6) WA 32 ARP -IN (0) 65 101-KDE MEAT (NET COOLER 0000100 60 3/4") (5) , FOGO 32oG4 VANS. REACH-1N DOORS (EXIST(N6) -0 (0) 5 (E) DELI COOLER 16'0 1/4 c (0 0000152 I (E) IMI-KDE (0) (EP I GE (Jr, M FREE,. 1 09 (0) (2/ sx64-2o4rGE 00 sa. Fr.xq (N) (2 1-X6E DELI 12-X6E op.) (E( 10) B O NOT SEE CLOSE OFF PANEL DETAIL THIS 51-EET. TYPICAL (4) PIAGE5 . 00 s-' tlEOCC2 EE ARCHITECTURAL URANIN6 FOR EXACT LOCATION. SEE NOTE NO.5 'APR 1 (OR Exp1RED (E) ROOF-TOP CONDENSIN6 UNIT - MODE, 0 NEI., 2,5. L135. M2000-223 g 2oor PERMIT cENTER SEPARATE 000000 0E0)5,000 FOR FilEC:!AmcAL. CITY TUkWILA BUILDING DIVISION SCALE: PARTIAL FLOOR PLAN POINT OF SkE/FIESH FROSRAM 1) 1 .) J -BOXES TO BE MOUNTED ON MULLIONS BETWEEN EACH DOOR FRAME THROU6H ENTIRE P.0.5. BOX. AZ I 41' -4 1/8' 141 ROOF -TOP 0CT0561N6 UNIT 'D' I01 DIlBNSIONS 55'48'x51'11 (APPROX.) roam 400 IBS.' (AB=Box.) (D.T 11GATILN DE158f1t. BY onus.) L.ESEND REFRIGERATION SYSTEM O ELECTRICAL CALLOUT • JUNCTION BOX, ® SOLENOID r�l CONV.BENCE OUTLET pT THEA'OSTAT bl AUTOMATIC DOOR SWITCH ICI WIRE) TL FAN CIRCUIT AND.SOLEN010 I., FAN AMID SOLENOID DE -E ERBI2E WFEfN I : .00R I5 OPBJED IOOW VAPOR PROOF LIGHT 'PROVIDED AND INSTALLED BY BSLTRICALILONTRACTORI 8648 MATS TIGHT FLUORESCENT FIXTURE. PROVIDED AND INSTALLED' Br E ECTRICALICON �4. 4'08 NAT. 016HT FWORE_SCENT FIXTURE. PROVIDED AND INSTALLED 6Y ELECTRICAL 'CONTRACTOR. ER60NOMIC LINEAR OUAD LAMP ELS H0 -101A INSTALLED 'BY REFRIXESATION ELECTRICAL. SUE CONTRACTOR. 41' -N I/O " NOTES HEAT TAPE 1 ALL JUNCTION. BOXES.. FOR.I EACH -IN DOOR LI6HT5 TOIBE LOCATED. ON MULLIONS. SEE DETAIL THIS SHEET. 2 OJBNHEAD ELECTRICAL CONDUIT TO BE RUN INSIDE' OF TRUSS WORK. 3.. ISLAND CONVENIENCE OUTLETS PROVIDED. AND INSTALLED BY ELECTRICAL '0050N0LTOR. NEAT 000LER/FREP SWITC-I LIOHTIN6 - PROVIDED AND' INSTALLED ON ELECTRICAL CONTRACTOR 41' -N 1/8" HEAT XL TAPE 41' -N I/8" TO PRA FT.x10'. +' 636 -135A 32'5' -NW PRODUCE (21 SN26- 146A 24'4 " . 5 /D 414110E DELII ',.. Al OF, WORK. 4. _ 11 9 O x ALTO 'x9 O'.H. Ni F ACTOR( RCCR (61 `rCb4WGE (41 515-556f£ /MEAT PREP. /1,141 SO: FT. 88,5 "IM1- KDE'MEAT" (]) PLP6 -154 DELI PREP. I 400 W. FT.. 12'4' NMI -KDE 12 -X6E DEL T. MEAT COOLER 34'0,40'0'x10'4 1 /4'H: 0 J 41' -N I/O ° 0 ` 12 I ICE CREAM FRHETER 9'0'x1'3'x4.0'H. (2) 5K64- 204K6E 84 SO. FT:x4 HEAT 3 TAPE CHICKEN ROTISSERIE • (BY OTHER) '0' _ hiOICA;E ( BY DTHC) R00F -rOP CONDEN5IN6 UNIT 140BEr 0PM14PM- M6/M6M0M6M6 WEIGHT: 2,500 LBS. RECEIVD CfTV OF TLK SEP 1 8 ZOD� PERMIT CENTER 0 CO 0 iC [ I0 T OTAL AMPS AMPS Pat LASE ISM 111=Ll■ U= - © _1111111 _ -E1■__ 0 SAL. PREEMIE 4 2 I/3 (Fa LON 515E (RAPER PL. SYSTEHI MEAT 000.2 1/2 (EI 54'%40'X10 MEAT COO-ET lit (E, Dal PREP 400 (E) G T 26,20'%10 MGT FRED' 1,191 b • 0 5z %4J'XIO CV [0] [® 0 M/D PROWLE (E) D6E SALDtlLE S.RER DI-LS. STSTO.1 BABY PR=E MO SI. t1. - /1615. FP (5x10 4 1 /4'F (E, (E) (E, SALE FREEZER 91 19'0'x64'0,15'6 1/4 ,_ SAL. FRE532 =I 5/31. ,513E SAL. rT$ZFR =2 O'z5 19 SAL. FREEi.� *Z 1/4 (W (W 13 re) 1/3 CYCLING ANTI -ShEAT FANS Alm CONSTANT HEAT35 ON HEATHS TOTAL AN°i ANFS PER LASE 208V SIIY'F PHASE • O M El i l mm illill1= II•1=I= NEI MEM [0 ® =EN TOTAL LINE CURFAENT 226V THIT PHASE 5Y.b4- 209KfE 2 : .4 4 • C U■ [ C• �� C•li Q • MIME 31 5MI54i56KE ( W 46O✓3 I.. 2 0 2.0 2 0 2.B 2 6 • - I . J \ I® � SV154Ti6R6E ( M 46O✓/3 I 2 0 2.0 2 B 2:B 2 8 C• - n C��■ • WALK -INS _EN_ __ [0] V "MEN SUF.L. ST5rEt BM • • • ] 2 . H K l 6 - 2 ' . 6 K l E ( F J 12(f/ /I 4 3 1 12.8 T 0 14.0 14 O • • 0 I_ U® HK]8 -2:6RE ( 120J /I 4'. 3.2 12:8 T 0 14.0 14.0 [- • [O] ilimaM1111v__[•]=1 @]■ • • [O] [•7���_�C•]� C-OO-® ..: Ll∎ • �� m] • ___ -�_ [.,.1■ 5146 -T46 ( N) .460!/3 2 2 0 4.0 4.0 MAIMMINIMI ___ BM • _N] [ ]EI [• IN■ s SM® [® cri ___C7IIMI _� C•] L7■ • • _�®_� [m] 0 _� �■ ' - • • :;.=,R, (EI 45.0 =__ . _ . ..-.... C ®] • �� [•7IMIN Cm]■ C•C• 11•1=1= [m] ___[ - -■ [• • ___ BM _C• -_C•7 COT® , . • • - I. ems Si --= (3 COH!Pf�30fS CNB [•] BM 14T SJ. FT I (0 S ® ®a K 96 ` , ,4, �. ['_ ®�_[•]_ [ ©7® 135A (FJ. 120J /I 6 16 9.6 [• [• _�_ BM SATd1ITE ® H[PA - O48WFf (EI 4.03 ®® TOTE MIO.NT® SATHlITE [ ®] Emsmim _® �® ® ®(] rr�® y [0 5 /DMEAT (J l''''' l S ®® 1 � 1 r � ■I • C• ® ® � ®] 0 5/D MEAT /5,A0 g') [ MI -K� ® ®CM� C•J :,�. 1 �■ �• • I ® ® [ ] F]. /D'.L1 (3) 1HI -AD 12'0: �N 1 E 1 E ! [m] (E ' 160i36'bO'4 I c H 536 -TSA (E) 0J/I 15 6 24 G 24 0 = • [D FR F COO 2 (U �WI l [0] (W • ®�� �■ � . 514 b T 46 A (W '.460//3 2 2 0 4 0 r . 1 : , 4 O • • ® MOM= ® [m] ES 19 O'x64'0'x10'6 I /4'H. � I., � I r� MBEIMCI _ • �J ■', SK2�IdA (Ei:,, '. 12W /I 4 :.1.,1 I.b 6 4 i s 1 6.4 [• • ® ® ®i C: ] 1 1 MI [• SObVM -M1 " 24.0 30.0 I [LNIP0. CIRCUIT • WYNTPIRiRI a 29 3 �' IT0.0 1"15 0 '': (/VIP R MOTORS CTLY C0] C �C• Imo® C Bill C• C• ® ®® [•] EN ..-- -- EllINIMEZEINIIMMIIIIIFEEIMMINECIaM1111•111111■1811111111■111111111111111111•MilaiNIMINEME 1 481 15_AND .1 .-% - c [© 531 15.. (E) C2-XT �I_� ' '®� [ M■ e ® ® ® [ 0] [m] Ib 1 COO �xlO'4 /4'H ® 31 I Ro:r- TOPLOm95[!G InN1r (d • - - ". ��� [•] • U■ [• ® ®® [•] [m] . _ j 2 2 [ ] [ [• �� ]■ C• • ® ®® [m] C•T • ®® € ] [ c (i • • MIME [0] •] ∎ ∎111=1=11C•MM _C•7IIII [•]■ C•RIMMIMI • --- 1•] [• IMEMIN[•]MIIIIIMIENI•1 •]_ C•]■ [• C•111•11111111=MMIMINI _ 11 NM • • ®® C•] i ® ® ®® ®] 7 ■ • C C • C 1. BB 1 WALK -IN LIGHTS (S _ MI FRS DOOR HEATER (E)-ICS- [0] - HEAT FRE P LI6,r6 (E, ®�-- ROlF TOP COMES A(, HLLV V841OM 24V/I .. 11Rfail -11 =MI 1215/ 4605/3 .■ SNE 1 DER FEATR5 ANDpNY _-- MINIM 5/JS FREE I (W LU5TO4 3 2' MILLION LIGrtS (� SV.S ritt>t2 �[] SNS FR53ER . 2 (F J ROOF TOP C066336 132 MACHINE ROOM ERi4YT FAN (� HoT CASE (E) CONVENIENCE OUTLET ( VENT MIA VOLTA./ PHASE 24V/ 1205 /1 201/1 120//1 E �� S � =I -- r© \'-'/I MACK -IN LIFMP (H -®-- I L YS O SVF� (U EREGIESIMMI 2.2 VAFOt F3tiP T{lL'�X.FNT :rtNY1D� (EACH) ,Nm crsu.m er ra3R1�r r4MrvACTLR. (;) e€ SH1d181 ®.DRN'g541 GGN2]L FGl T TO SMPHt R'l15 SY S K ' A . 10.0 (5)XIFE CCMTCL:LIRGI[t t0 .PHt R.L5 ZYSfdf O. IT.O WFBt SUPRY. S. 11.o PaEx (IS,WII£ 5H1134ID BFLWN •541 [QNT@JL iRLUlT 1a 51t£¢ PJ15 5 CONTROL PNB A 10.0 ' (5) X11£ RIPPLY. L LIPCII[T TO 51F532 ftJ/ 5YSTSI RIPPLY. a El 10'FI%RAFSAT 0.6 T 0 AM EACH. Sg NOTE NIIL'BL 14 . 15 5,E) 1 DOES 41 .6(W 64 FI%TLTES AT 065 AMPS EACM. 5. NOTE NIMBER 14. 33.401) 46 PROS 51 .:2(E) SEE 52 1 FIXINES AT 0.60 T AN EACH. . NOTE NRE� 4. ..5(E) 39 OCNNS 14.2(N) 48 DOORS RIM SI SIC CREAM SP SPA. D.LRIPT1. x9' RACK HO1M. SATdLITE SAL PS TTEEEER 41 0'6640,166 /4'H SA_. FRS LENS, LUANTITY TOT, REPRI6ER<TOR ELECTRI DEFROST COILS MODE- 0361 VOLTAREA ODE- VOLTAGE/ PHASE 120V /I SAL 12 FANS AMPS 'ER FAN 1.6 AMY 12. DRAIN PAN HEATHS AMPS. TOTAL 'Bt COIL APPS 24 TOTAL 24 COIL EL.ESTRIS DEFROST VOLTANE/ RIASE KCA£d5 AIDS FAQ COIL TOTAL 113 AMY COMPRESSORS pR.E VOLTAEE/ ROVER RUSE CI HDT MTENELOMMIEER L2 Tr's' (F] O'I OECRIPTIOJ R6RIDEPATICN T -S TAY 4. 50.94.5 1 (E) D9R6i7 52LE40111 (E) VOLTAGE/ 25AI/1 DETAIL SHEET R-6 1205/ MISCELLANEOUS EOU IPMENT RN TO 10. 10. (HCW 0.0 EA . CONTROL WIRING SCHEDULE FROTO -ANTE CAMEO: HAND- HEAT ANG HEAT TAPE 64 FIXTURES AT 0.65 REWARKS RUN (4) WIRE TO P96TO -AIRS CONIRLL PNg (v WIfES !Oft 50.@biD I (2) XIR. FLR COMRi�R LOWTAGTOR. SSMAMN oRAYlIN6S, APPS EACH N N'LR i. Di 1. R Z FIX,Irt YDR ID mi../ BY R3RF8ATIO1[ONRALTCR PROVIDED AND INSTALL!. BY ELECTRICAL CONTRACTOR gEDE1VED CTL." OF TUKWIUA SEP 1 8 21 PEPMIT CENTER co 0 cR 5ER.4"JZ� 10 REVOLVING RED LILT (BY E.G.) MOUNT IN HILLY VISIBLE LOCATION. VERIFY AND COORDINATE E%ACT L(KATION WITH ONNER. PROVIDE 5I6N BELOW EACH LIGHT INDIGATIN6 RACK (LOW TE'f . , M. - REF.. ETC.) SUPER PLUS 5Y5TE4 CON1ROL PANE_ A BELL PROVIDED BY HU55MANN VERIFY AND COORDINATE E%ACT LOCATION WITH O ER. INSTALLED BY E.G. REFSISERATOR 1205 CIRCUITS 10 REMARKS ECU IPMENT SCHEDULE IE) EXI5TIN6 (E4) EXIST! N6 MODIFIED (Ey EXISTENT RSDCATED 115 NEW (U) USED 6EERAL NOTES 3. 5. M -223 La4 APR 1'8 2002 USE MATERIALS AHD METHODS OF INSTALLATION THAT CONFORM TO ALL AFRICA. CODES A. OFNINNY.. NO ALUMINUM WIFE SHALL BE USED TO CONNECT AM' HU551..MN FURNISHED EOUIPM9N7 . Y122, LCCATIOS OF aECTRIC. 511.13 -UT FOR REFRIDERATED CASE WITH R3=RI6ERATION U>M'KTOR PRIOR. TO INS'NIATION/ROOR POUR. SLRFALE' ALL CONDUIT IN FLAB. REFRIGERATED NALX -IN BOXES AND SEAL ALL PHFORATICN': WITH FERMUN OR RIS5MA.1 PPPROIED `.F15LANr CO.. AL BLOWHN,COIL FAN MOTORS LOCATED IN NALK -IN 50.5 TO ACCESIBLE DISLOJSLT. 6.' FURNISH ATV,' INSTALL COmU1T, MITE' OUTLETS, ETC., FOR TSFR16ERATILN CANS AND CONNECT COMPLETE H.® READY To OPERATE: A5 MFRCT ®.BT TI{F RaT I6EWTIOI CARTRACTOR. YN w.T5.51_ CONTRACTOR' ALWARJISH G41 ANY VSAR! DI520NNFLTS., CONTACTORS, CONTROL. RELAYS: ETC.. *Hal ARE NOT S°FL BY fiYf�M1ARN: T. REVISI RME HECTRICAL PIA. AND DIM.. PRIOR' TO. STARTING MIRK AND CONTACT INS.. IF CLARIFICATION 15 NEEDED.. UPON. COMPLETION OF WIRINS;..THIS CONTRACTOR SHALL ,PERT - ORN A .71...TO:1 OP.AATIOUL' OOMROL SENI9NLE LtCLK WITH THE RERIEE ATOM CONIRACTGR, BY RIMING OJT ALL CIRCUITS AND COPSECTING WIRING. ER@'AS. 8..'NCVNT A.WER :...CT ALL THE POSTATS, .112JOIDS DAD. 5/T5ER E ECTRILAL CONTROLS FURNSHED 8Y R FRIDERATION AND /OR AIR CODITIONIN6 CONTRACTOR. CONNECT ALL MOTOR, CO.OLS' OTHER OOPOrBLF FURNISHED BY THESE CONTRALTO. 9. FURNISH AND : 1.7.1 ALL FOR CCNDU(T, hIFEOJTLETSLTL.,. ALL LIbHTS. HEATHS, 2.-[N EDJ. ANON /OR PEACH - IN AND INST I.L AND PLL ELECTRICAL CO AS TOR tiEE, FIXiU P3E W@IfSV�BY. Ort♦9Fi INm.INSTNJ.® BY .THE gPr.TRICAL [ORRACTOR 10. ALL COmUIT FOR REFRIDEtATED :CAS UMHY EUILDINb FLOOR ADO TO BE MINIMUM :1' RIGID'. STEEL OR AS. APRNOYED BY LOCAL COW AND THE N. E. C 1I. ALL ...N CASES HAVE EITi TWO OR THREE ELECTRICAL CIRCUITS TO DE CONNECTED CONSTANT ON ANTI -.'NEAT .7E25 Aim FANS ARE TO BE WIRED TO A COMMON PANEL FOR CONSTANT aERAnaN: LYCLIN6 ANIMA T tE.. ARE . Ig WNi®.To A COMMON P.a. NI DI CONTACTOR TO BE TUR5 OM PND IDI5 TAT YO11N® IN SALE AGED. ' LA£ LIGiT' CIRCUITS HE i0 or WIRED TO A CO9KAN PANG WITH : CONTACTOR FOR 51.LE SWITWI ON OFF 12 A LAI WIRINB - TPE WAITE A �L ADD LIERI ARE FIEND. WIRED EETYE31 T�IINAS 31, 32, AND :. 33 N@! FiLS SYSTHI (5) AfE U5® itE ALARM. BELL COWELTED BETYEEN TERMINALS 32 AND 33 "IS FiIRNISF BY IiJS41A AGE INSTALLED BY ELECTRICAL CONTRACTOR (NAY LOA '.i :O AMP AT 1. VAC) 11E AL LIHTF WITH R,A`k� UNIT, my rE NL E R NET INX LOAD '. 0 ATM TERMIN 31 PND 33 I5 RIRNISH® AND INSTALLED Er ELECTRICAL C O2 (W1. 2 Al'�S 120 VAC) SEE WIRING DETAILS." 13 ' RIVED DISCQRNELTS O2 MOTOR STA¢THS AGE NOI"SUPR.IED 8Y H15aMMN UN..S SPECIFIED OTtE3dY15E. (5E a w.TRICAL DETAILS INCLUDED WITH THIS SE'S (F CRAW[N65) 14 H.FCTRICN. CANiRAOT OL OR TO CORffLT Au_ COH? AM 55=5 DOOR LIGFgS TO 9�6Y HAN4:earn '.1 P MB- PRT / ION®' BY O IFBF> . , 15 ,.FAILSN DISCONNYG� T ITCH MUST DE9NE'G12E P.RI6ERANT SO_HbID VALVE ON ALL WN C -IN EVAPORATIVE CO ST 6. EECTRICAL. CONDUIT TO RUN INSIDE OVREAD TR,55-HoRC 11.E PROVIDE A5 -5UILT FAME SWI M/. FOR ALL EL ECTRICAL LOADS 5.51 ON HU NOTE THIS ELECTRICAL INFORIATION IS.TPE PROPERTY OF 511.).1. RERMG9RATION, IW 1 IT 15 FOR TE USE OF. P95ON/PEPSOI5 B( TONRITE PLANS ANDS CIFICATIONS, AND IS INTENDED -co 5525 55oun8955 FOR PERIEERATION' AIR CONDITIOVING "AND FIXNRIZATION A5 R9ATED TO'' EYUIPMHNT AS ' FROJII'BC N15FUNN. KILKPLATE OF CASE DIMENSIONS A5 BHOWN ON PLUM51N6 PLAN KICXPATE OF C FLOOR SINK 1/2 EXPOSED W/ 1/2 GRATE COVER LUMS SCHEDULE. 24 X 24 °. BLOCK -CUT FINAL POUR TORE MADE OFFSET 5EaD IF REO. FOR ADJUSTMENT 5A,1.RY COOLER 2CO `A. FT.x10'4 ,/4W. .59 FT. DTANSION (o) iG6A -166AB ...NIG, HOUSE 11'6°525'5 ° ,I0'4 l /4 °H. 16' -8° TIE INT EXI5TIN6 IL WASTE 5TU -UP (FIELD 1,1 PRODUCE COOLI32 16'0°x36'6'z10'4 1 /4'H. 52'5 -M412 PRODUCE: '4° 5 /D',IMI-KDE DELI (41 sxv5 -556K. MEAT PREP. 1,191 50. FT. 66'5 IMI=KDE MEAT'.. DELI COOLER 16'0'224'5'x10'4 1 /4'H. (DJ ACF6 -I52 DELI FREP. 400 50 FT. 12'4' IMI -OE '. 12'4' L2 02.060'. DELI TIE INTO ISTIN6 COIL TE 51118 -UP. `IEL D VERIFY) ROOF -TOP CONVE.IN6 UNIT '. °V DIt045I0N5: 55'x46'x51'H.i (APPROX.) /car : 907. , (AFPR7X:) (DUCT LOCATION DET5E4I. BY mt..) PLUMBtNS LE0EN5 O PLUMBING CALLGUT D FLUM51N6 5000-0 • (EKISTIN6) CA5E /COIL CONNECTION (MEW) CASE/COIL COWVECTION COIL WA5TE STUB UP.1 :5EE ARCHITECTURAL DRAWINGS MECHANICAL SET, FOR DETAIL ' 0 FL000 5I00 5E. ARCHITECTURAL ORAWIN55. MECHANICAL SMUT FOR DETAIL 12x12" FLOOR SINK �15EE ARCHITECTURAL DRAWINGS MECHANICAL SHEET FOR DETAIL.' (3) 5K56 -255A PLUMBING N0TE5. PLUMBING CONTRACTOR SHALL:. I. USE MATH21AL5'AND MBTti0D5 INSTALLATION THAT LONFOW7 TO ALL APPLICABLE CODES AND ORDINANCES. 0. FURNISH AND INSTALL ALL FLOOR GRAINS. FUtUH_ DRAINS FOR WALK -IN CO AND ALL OiMER PLUMBING .1'7'5'. I 3 FUWIISH AND INSTALL WPPE4'OR P V L LU�BJSATE DRAIN 'LINES FROM. REFRI6ERAT® GASES TO FLOOR. DRAINS i}E', NOMINAL PIPE S1ZE SPECIFIED I , ON TFiE DISPLAY,LASE SPELIRLATION. � � '. 4. N0 WATER 56'{42, 645 LR V@1T PIPING SHALL BE IN5TALLm WITHIN ANY IMSULATEO CigLE2 OR FREEZHt WPLL. '� 51 FURNISH AND INSTALL 1' WHINAL RIFE SIZE. COPPER OR PiV.0 COtb85ATE vIf DRAINS FROM WALK - CWI..82 /FT�ff.6 ND 0 1 ,* I' 1 Pfd. ROOM :LEILIN6 COILS,. TO F7IMPJEL GRAINS A5 �CTED BY 1$'RI6ERATION CONTRACTOR. THIS PLUt19IN6 It60W ATION IS THE PROPERTY LF H)55MANN REFRIGERATION, 'IND IT L FrRITHE u. OF PERSONS 5HEE157 SY TO WRITE PLANS AND SPECIFICATIONS AND IS INTENfiao TO SHOW REOIIIREI@ITS,FOR RE RIGERATION,AIRICONDITIONINS AND. FIXTURIZATION'AS MATED TO EOJIWEIVT )A5 SPECIFIED BY HUSSMANNI IT 1ST. rEiPOMSIBILITI' OF THE ARCHITECT;ELECTRIGAL AND MECHANICAL ENGINEERS TO VERIFY AND COORDINATE ACCURACY OF ALL PIPSSIONS WITH rnMRA /.TlAS AT , .THE VIRSITF A. TIJ4IGF THAT INSTAI.I'ATM. rINJFA. TO C-` CREAM FREEZER q'0'z1'5°x9'0"H. (2) .0,1narAr 89 50. FT.x1'0'H. 4 ' e10! CASE (130 OTHERS)' N ROOF -TOP CONDENSINS UNIT - MOBt 0PH1 M5tM*MSM0145 .16K. 2,500 L35. LINE SIT LEGEND 1/8' x 4 = 1/2' 1 1!8' x 5,.= 5 /8' • T = 1/8' • = 1 I /8' III I/8' z 11 =.. 1 3/8 ". O I /b' x 13 = 1 5/8 53 I /b' x IT = 2 I/8�". BAKERY COOLER 200 50. FT.x10'4 1 /4'H. WO S't. FT. DFANSION (2l HC4A -16645 MECHANICAL MOUSE 19 4 I /4' H. 1 5/8'- 19 s /2' sta.. I. I 0 •F _ i .1 LEGEND 41' -9 1/8° O REFRIGERATION SYSTEM (EXISTING) OJ<NF. A,, LIQUID LINE UNIT CONNECTION LINE SIZE TRANSITION LINE SIZE'CALLO/T • HAND VALVE • SOBIDID VALVE PATE -END LIQUID LINE Rte -TOP CCH7B5IN6 UNIT 'D 110 . I$.F -2 -LT 1211 51C. 55'z48'x51'H. (APP..) FEiblii: 9co L85. (APFR7X.) (EXALT LCGATION DEERMIN® 3Y'.011.5.) 7 1 5/5'— 1/2' 41 4 Yt4'rY.. 2) .36 -135A 41' -9 I /8" I 1/2' WRENS - 18 (T'P.) It 41' -9 I /8' PRODUCE COOLER I6'O'x36' 6'X10',4 1 /4'_H 5/8' n V 41' -9 I/O" 41' -9 1/8' 3 5/12 NCI 32'5' -NMR PRODLILE IMI -KDE Dal'. SALES F #2'. 9 x46' I "z9'0 W/, FACTOR( FLOOR,, (61 SK64plIK�i DELI COOLER 16'0'x24' 5 (2) AC50 -152 O 12'4 I ICE CREAM FREEIER O xT' S'x9'0 "H. (2) 5K64204K6E 89 50. FT.x9'0 ° 1-1. CHICKEN ROTISSERIE D T CASE (3Y OTHERS 1/S T/8' M2000-2 1 I /8" ROOF -TOP CONDENSING UNIT - MODE,: 0PMY4N M5/M0M0M6M6 HEIGHT: 2,500 L55. FALSE COLUMN PIPE CHASE, SEE DETAIL THIS SHEET. E 1/2' PLYHOOD'CLAD IN SHEET METAL TO MATCH COOLER PANELS 2x2 FRAMING REF PIPES FALSE COLUMN', PIPE CHASE FALSE COLUMN' FIFE CHASE BAKERY COOLER 2M 57. FI_ x10 . 4'1 /4'14. 200 52. FT. EXP.. (2) iYSA -1EGA3 0 1 1 /8' RISER 41' -9 1 /8• LINE SIZE LEGEND 17 I/8 x • = 7/2' O 1/8 = • I/8' x 9= 1 1 /b•. 0 '/8' x 11 - 3 /b` • I /8• x. 13 = 15/8" 0 1/5' x I = 2.1/8" (RISKS NITH EQUAL LINE SIZE N67T REPRESENTED) 9'0 ° LEX BAKERY SALU 'K2- 9 O'x46`il 'x9'0'Hs H/. FACTOR/41 FLOOR" IN SfM01Kff RISER DELI COOLER 16'0'x24'5'x10'4 1 /,4'H (2) AGP6 -152 we; B' 5 ' IMI- KDE'MEAT 3/8° LEGEND 0 REFRISERATION SYSTEM (EXISTINS) OVERHEAD SUCTION LINE RISC, UNIT. LONNECTioN LINE SIZE TRANSITION LINE SIZE LALLOUT (NEW) O/BV-IEAD SUCTION LINE UNIT �TO SINS DI!@75ION5. 55'x48'x51'H. (MP. %) )'EI6Hi: 9Cb (APPRO %.) (EXALT LOGATION'LETHWI.? BY 0i s.) 41' -9 1/8" S 4 6H A T0 S /D NCI'i,, 1 1/2' SCREWS - I6' O.C. (TYP.) 1/2' PLYWOOD GLAD IN SHEET FETAL 'TO MATCH COOLER PANB.S. 41 I /S 1 3/B' RISER1 •} i -- �f- - - - -1 (3). 5K56 -235A 0 13/8' PRODUCE COOLER. RISER 16'0'x36' 6'x10' 4 1 /4'H. 8 1 5/8 RISER • l/8 RISER • 13/8' RISER NEAT COOL. 34'0'x40'0'x10'4 1/4 3/8° --------- -" I I/8'. ". M1 =KDE DELI 11 ►i 2 I/8' 41' -9 I /8" 41'-9 1/8" 0 ICE CREAM. FREEZER 9'0'x7'3 "x9'0 °H. (2) `X54 -20.5E S9 50. FT.x9'0 ° 11. 2'4' 62 -56E DEL T'I5� G2 -X6E 12'4' 42 2'4' Q2 -X6E 13 /S" RISER CHICKS. ROTISSERIE — 13//8EY 07/4. 5) 51 CASE (BY OS}EF5) 15 /e "J } , - k I O S 15/8 R70F -TOP CONDENSING. UNIT - MODE, OPHY4PW- M6211®F16MSM6 YEi6HT: 2,500 LBS. FALSE COLUMN. PIPE CHASE, SEE DETAIL THIS SHEET. 000 E xptaeo FR 1 a'2aa2 DELI COO.FS2 16 O'x24'I'z10'4 I /4'H. !EI ROOF -TW GOh 5.151,6 UNIT 30 000 f8A - 3 -LT (FJ CAPACITY 169,,010 19 0451413466 lL41EYi16 ®®®®®®®®®® I 9 531 [SEND (c G? %fc 12'0• 2 40'0' p 46.400.. 21 PI -4(E) l9YfKP1 I � 8 0 2 40'0' 29 46,400 21 PI -4(EI TmTiEJ g Q DELI 15LANR !E) c2-Xrs 12 O' 2 IN - EZIIIIMIEMEMINGEEMEINIMIIEMSEEEE111111=MIMMIBE=31111EllEMIIIIMMIUMENIIIIIIIIIIMEINIMIIIMMIIIMEMEEIE F S (E) 163, 92.3$ __. . 1111 ®� ® ® ® ®� - ® ®_ ®_®_ ®C•] Co __ ■ -■ _III_ ___ 1_1111 o Col � __ ■_■ ___________ ______CO] [o] -__o o_■ ®■ ®vUIIM_a_INEM_s_MMCO] Co ® 1111 ®■ ® ®�® roo� - - - - = = ® ® ®ii ; iiiii: ; - u __niu LONUBISER ®MIIIIII®_ ®- _ ®1111111111®11111111ME ® ® ® ®_ ®_ ® ®® ®CO] ® ® ®•11111111111•11®_111111111111111NME_ ®__CO] UNIT MODIFICATION AND ACGI SONY OFSCRIPTION SATELLITE OIL MODIFICATION HIGH END SATELLITE REMOTE SATELLITE SINGLE POINT CONNECTION ISECTRICAL ASSEMSLY LIQUID GRIER ASSE13, HEAT REGAIN VOLTAGE HOD. WINTER CONTROL KOOLSURSE RENOIE SATELLITE ALARM 1040TE N ARA ALARA B31 HIGH PRESSURE CONTROL LON PRESSURE CONTROL OIL FAIL.. CONTROL HE. RECLAIM LOCKOUT SPLIT SUCTION SNIT SUCTION OIL MW: ERG,SRIT SUGTIGN CONTROL SPLIT CO5D01502 . PIPING EPC' COVENSER FAN CONTROL TF€@LA -'TOR TANK (E) ERG LIO/ID. LIh ?RODE BALL VALVE . T in. Cam! BALL VALVE.0 /FH011 H.R. 401.1 551iN ONJ (2) 415K -. NMI 1111 , _®_ ®p - _ _ _® Z __ _ - _® TIDE - H (6)4 2,6 (2)24tH (6)4 2,6 (2)24tH 6l VD PSIIR I O/J SIC LIOIID EXP VALVE _ ID �T Tr. � ® ORI �� T -STAY � INSJL FEAT ACNAL ®' EtlU1 rJ"JIV .- SORT BOARDS ©�.. Mpg PA.S EXGR rI, , • T[ME © ®© i W RA M W� : N ® L'''' OF NUN .- � = 2 =© - =-- =- _- -a - -_- =mom - -- - ® ■ ■ •••••••••••••••••=1111=1.1 ____CO] ©] 'ARE ® ®■ 11•11•111111•1111111•11111111===111111•11•111111•1111111•11111111===11111111111•1 11•11•111111•1111111•11111111===11111111111•1 == �s■r[ ®7 ea SALE F� al I/4 lu,) -5 SD.OJJ _ -14 -® r'- ®■ ®S -4Z (W ®�__ ®__ ®_ ®® �_` ®000� r 9 0'x6< O'x1B 6 1 /4•H C 4 1 :. 00,1B /413 'i' (W Mil -5 SO NM -14 - ® = ®■ ■ e.--. (W ® ®-_ ® ®___-®IM_ o 5 A•E __.111111 __ ■_. ��� ®_ =�_!� ®!_MI�_EC®] C© 95 O'v4B�0' ,, I� (� - ®�- 15 -- 0991 (:1 _® E 11111=11111= ®-IIII_® -______ ME ! • 51 W (5X=2 F.5 5Y5T3J -_- -il 3 CQEt (B _. -_� ®_ ®_�_ -___ __` ©I o B� _ ■ -■ ®��MM��iIMMIE ��� MIMIC BE , 28 31. 20 _�� ®_ ®���- ___ _CO] ■r[O r •• r - •rr 20 - �■ ® _ ®�_ ®_�__-_ ___ IMCO] IN 400 S (E" 50 -2.0YJ - ®-_ ■_■ ® ®�__��-- ____ ®CO] CO] 20 %'XIO 9' t - ® =� ® =■ ®� ®_-_�-__-- ____ Cm 19 0 x6i b 6 1 /4'H 2 (u ��IM■�■ ® ®�__--__---_ �___`�000S C© 11E1A91 F 0 5.00 - ®=� ®© �� ®___�_-�_______C® l ©] : • _ lmommra ®oom■=m■- ®E N.(E/_-®____-i______Cz] C® BAKERY'T 4 -�r ®�® ��_�__ _ ®_-_____MC®] ■ r 350 YN. FT. /Ibl Y. F. , x10'4 I /<•H_ (^I 2ODJ Cm x64'F�O�x�I BRB 14' W r r•• - = _. =■ _ = ��_ =•- EMI____IMI_RE ��] 59 O'xKO 6 I /4'H. ® 50.000 - =_■ _ ®_� ®_®�MIIM�____�_C®] CO] 9 3 M 1 'N. Try (U �� =_® IM ����_��-__M__M • 9 p v-rr 3':5'5 H. Try - 1 (J 3 ® =_ ®® (FJ -�� ® ® ® ®�- --__ __� ®] LOW SIDE ('NAPES P115 SYST?U (� 25, XG -1T I) 15HP [ y 2.. (� 241,825 90.9$ ■■■■■■_■■■■■l� (U 50 52,0,6 30 IILA(U (El 69VP (E) ® • (U 52.0,6 ]B HI -04B (E) 55.100 934$ CI 5/0 ,FA . .'M 2 0' MEMENIE 18 20 (E ' ' , 1111 1111 ®® ■ r 11 C l]5 /D''T'''' 1' 'MI'. _B®®®®.iB ®_■ ■ 1111 ® ®_® ®M C®] 5/D 01 (E) TMT'9E __IEIOM® ®® ■ ■ CZECIBN ® ® ® ® ® ® ® ® ® ® ® ®C ®] C®] " 6 6 'x 4 i 4'H. (� _ M11111:11=1■ t. ® ___ ®____ ®_ C0] ®111MON01=11 ® 1111 ■ ®_IIIII®®_ ® ®_ ®_ ®NCO] CD 19 - 0 x 64 O _ ' 1 /a •H 1/2 (W -� -© ®� ® "r ®■ r,. ® ®�� ® ® ®� ® ® ® ® ® ®® ® ® ®C ®] r - ■. rrr bIV�(E) ® ®® ® ® ®_ -1111®®® 0] r ® ®61V.Ni (r7 ®® ® ®__I -® ®® C0] C®, • -� r•r 1111 ® ® ■■ Co] ■■■_1111=MIE •- ®! ■ ®■ 33 UNIT LETTER COMPF3a60P P051T WMPFrSSGR COLE LP.1 550R ASSBE_ FAN ASSEMELY DEMAND GO., MOTOR CONTACTOR NEPA MOTOR CONTACTOR OIL LEVEL R-SUUTOR DISCHARGE HUFRJ3t REFRI6HUNT DrSG131.1C4 /6 SP MONTS, 5 41 b P2EP. 41 SN. FT. x10'4 I!4 SATELLITE COM°fR SUCTION TEM1P (.01913 TEP S050 CAPACITY IVO 513 001 -1 S T£SLTION KILO/6715 400 -1500 471--1500 P 5DT -1 56 500 115 640 65; Vo 5. I INS 45,840 65,120 65,720 I 5.60 560 Orl 001.656 FOR MODE 50A -0600 PER U.M.G.) TR ITE ( (:0571 AL 3WO900 43 5 .62 R -22 roD= iJ3J675 51IJ_ 24.0 (EXI5TIN5) 0 IEl 52A COMPRESSOR SUMMARY AND AGCESSORI ES (EXISTING) � Q (EXI5TI 5 26 . BH •=1•=1 0''500 2GG,500 4W -1500 405- 0 4DS22L12 IBM - m ® ®- r ' L - ®® ®©��® ® -����- NNE - YH Yi'1 --� ------ ®�m�� ® •® 1111® ® ® ® ®IICZEMICEINEMMIIIESIN_- --® - -- - - - - -- - -- - 1111 __1111 4.03 534' 11 16 3 1 6 31 9 l5 3 43 1 3 B2 3.82 ' 382 -- RIB 1® R 2].. RImo. 1111 , • 11 11® II ® 119,000 II , 0 0 o 119,000 45;455 64,100 TS OJ 'IS II ,000 II ,000 NIT, L00 B . I 60 ,OW 160, 000 160,^' - ' 0 6 104,000 23 .0 123, IST WO 151 '�151T�� 26. 10 (EXISTING) 0:0 REf 16ERANT LINE 51ZE5 IC MAIN 14I6H SUCTION CONFESSOR CONTROLLER OVERSIZED RECEIVBN '.. SCTION MANIFOLD IMEULATIO2 51 1 UE000LI SIRC00LER TXV II ::' := ME MILL____ MILL___ III ::1 ( (PPi ■■■■ MIL DISCHARGE MODIFIER _1111__ _1111____ 1111■___ • -MILL -__ I KOMILATOR MILL . -® DELETE LI tEAGE2 / S - MILL_ _ GWPEt HI -P∎.S .. LINES •___ -- _®__ __ MIL 8� M_ DE,. T BOMm MIL L- 54FR _ LIO)ID SOLENOID MILL_ 2FR HAND HELD DISPLAY - -_® 40,0 AN 9lFAYHi _ IIA 3 KVA TRANSFORM., MI MILL__ _ MI _ MILL_ _ TIERMA -'TOR THEN G5TAT ISOLATE. LIQUID EfG SATELLITE CORM, 3 /,' 'ENTICE VALVES MALL LIQUID LINE ID RATE, PH/SE 453013. GOFUNICATIONS DISCOAECT CC fEATER BREAKER SOLENOID LC NOTES (E) UNIT LETT'=R (B NI MODIFY CORRiCR PIPING AND CONTROLLER PRMRAFM % TO .1 CONPFSiOR N11413ER '4' AS TME ICE CIEAN SATHLtT. 0O4ir.SCR N MER I' MILL JOIN TIE LOA -SIDE 5KTILN 6PEUP NOTE: ADD (I) TFEE415TOR TANK IN PARW.IA rum EXISTING TA APR 1 ZW1 M2000 -223 t-+'; 6ERA 26.0 REQUIRE) CAFAC:"" 26 COMPRESSORS 0 EQUIPMENT SCHEDULE (E) EXISTING (EM) .15TIN6 MODIFI. (H EXISTING R9_aATED (N) MEN (U) USED REMOTE GONDE"' UNIT� FAN LOIiROL FINS PER INCH TD FEFCTION (STUN) NO LF EARS FULL LOAD AIRS NIN CIRCUIT 16E5 MAXI!. OYER CURRENT PROTECTION 1816 i. MIDTH FEfONT r[6Mr DISCP R6E LIME LIOIID RErtm LICE H.LV- V33410H HP/ 061E812 10 145 2 ,X4 b 0 166' 2 1 5/8' 2) 1 5 /B' ,RACK'i01514T5 AND DIMENSION5 NIDM X LBNSTH A (E) 35'x166 HLV- V541211 HFV06.312 12 14.5 521,000 2X 16 .6 166' 96' 55' 2, BBO LBS 12) 5 /B' x ' 1 2) 1 5/8' tE16H 6, 46 LIE. RACK SUMMARY AND ACGE550RIE5 DESIGN GONDITIONS R3AT VE NMIVITr LRY EUL6 90 HET BULB 69 IM51GE DESIGN T@H OUTSIDE .516N TEMP cONpeEi TYPE VOLTA 8340 E AIR COOLED Yals SUM, PLUS /IPROTO- AIRS co 0 0 INSTALL (I) BAG Fi0LDH2 PER MEAT LASE. FLASH R7NAININ6 6AF WITH NHITEEN3,8SSED. STEEL PTO MATCH COOLER PANELS SLIDING WINDOW SUPERSTRUCTURE. AND FRAME' ELEVATION INSTALLATION CONTRACTOR TO ADD...ASE OFF. PANEL AT FEAR OF CASES.' CASE TO BE ..INSTALLED WITHOUT UPRIGHTS ON BOTH THE 8' .AND 12' LASES. (8ND UPRIGFAS. TO REMAIN.')' REFRIGERATION PIPING PIPING PENETRATION WITH FOAM. CAULKING BY REFRIGERATION CONTRACTOR'... I/8 " =1' -0" HLGV -V8 CONDENSERS PURGE VALVE F �zl ✓� �I EQUALIZING LINE SUMMER/ WINTER SIDE OF CONDENSER 15/8" I LIQUID RETURN --1 1 5/8" LIQUID IZTURN SUPER PLUS SYSTEM PURGE VALVE, CHECK VALVE, AND HAND VALVE FOR EQUALIZING LINE ARE FIELD PROVIDED AND INST CONDENSER MODEL NO. HLOV- VO410M (SY,. A) SPLIT CONDENSER PIPING 1 1/8" "N LOLL INS COIL WP= SUPER PLUS SYST. Il i _ -__._. _._ -7I� I � 120V 1Pn TO HR VALVE ON SUPER PLUS SYSTEM F ALL WATER LINES, VALVES AND CONNECTIONS PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR. DUAL THERMA -STOR PIPING WAL PANEL DOOR PANE MEAT CASE END LAPS I I /B'LLEARANCE BETWEEN FNn (.AP AIM. WAI I PANFI 96" ENE Ei=VAT ON 108' 108' 220" SIDE ELEVATION SLIDING WINDOW. SUPERSTRUCTI FRAME TO 51T ATOP THE MEAT LASE IN LINE MU H LASE JOINTS. GAPS REMAINING AT ED OF THE LINE -UP ARE TO BE P -ASFED WITH MATERIAL IN COMPLIANCE WITH ALL APPLICABLE CODES. I NOTE: CON 1...5 TO BE 5, LEVEL IN BOIL DIRECTIONS. I 1 0 C A L E NONE SUMMER ONLY SIIE OF LONG ▪ 1 5/8" ��DISCHARfE 1 5/8' DISCHARGE 15/8' FROM HEAT I REGJ�IM �1 518" TO HEAT' RECLAIM 91C -ION MANlr'Oy TO DRAIN T H;ERMA-5 T OR AOUASTAT 15kI NOTE: - ALL REFRIGERATION VALVES, PIPING AND .RN.7AT5 °RCN,. AND INSTALL. BY REFRIGERATION CONTRACTOR. FACTORY SUPPLIED AND INSTALED. VALVES SCALE LW THERMA- STOR'' TO STORE HOT .WATER TANK SCALE 8 NONE MEAT CASE 1/2" A P ARMFLEX PIPE INSULATION. PIPE CRADLE LAYOUT TYP. 5 SPLIT CONDENSER PIPING TY, 3/16' )A` TP. 5/16" 1 I/2" ' 2' • I I/2' THNEAD POD PLASTI TIE WaAPPED (x2; - TYPICAL REFIIGERATION SICTION/LIQUID LINE. CONL ANCHC. DETAIL. NO.1 ZING STEEL BUMPER i OF 2 12•-0' 9 /Ib" 0 HOLES 5. MI EACH HANGERS TO DOUBLE TIE - NAPPED. PVC PIPE - .ED/LE 40. UNISTRUT 14N0EG- (ALL PIPING 4 REFRIGERATION ELECTRICAL 15 TO.FOLLON PLUMBING c HEATING LINES WHEN POSSIBLE). SCALE NONE SCALE NONE PE 4' W 5TO x 12' -0' PIPE 2" 0. 5T0 x 9 \PLATE 0/0'25"x8" SCALE NONE 2 MAIN DISCONNECT OUTDOOR CONDENSING UNIT WEIGHT: 900 LBS. HLA -2 —LT 3 NOTE CONDENSER TO BE MOUNTED LEVEL AND TRUE IN BOTH DIRECTIONS. 02NDENS62 NEIGHT: 2,500 LBS. SUPPORTS ELECTRICAL ACCESS PROTO -AIRE CONDENSING UNIT ZING STEEL BUMPER 2 OF 2 GEN. CONTR. TO PRN1DE A 1' -0" X 0' -6" I.D. ROOF OPENING WITH CURB FOR REFRIG. LINE PENETRATION. II LOUVERS 1. CONDENSING UNIT TO BE MOUNTED LEVEL AND TRUE IN ALL DIRECTIONS. 2. EXACT LOCATION TO BE DETERMINED BY THE STRUCTURAL ENGINEER. 3. MIN. DISTANCE BETWEEN CONDENSING UNITS 3' -0 ". 10'3 t /2' ..' ELECTRICAL - REFRIGERATION CONNECTIONS LLNNELTI SPIT SUCTION COAECTIOIS. REARVIEW NOTES SCA NONE S ZINC .STEEL BUMPER NOD 1 c-- MECHANICAL HOUSE LAYOUT NOTES I.. 01T DOOR. CONDENSERS TO BE MOUNTED LEVEL AND TRUE, IN BOTH DIRECTIONS 2. (2)''60'x6 " °MUIR. FOR :REFRIGERATION LIDS:... COORDINATE EXALT, LOCATION WITH . REFRIGERATION INSTALLATION CONTRACTOR. PENETRATION AND ''IEAT!-E PROOFING' Err' 6 we._ CONTRACTOR: END CAP ROOF TOP CONDENSER LOCATION (EXISTING) SUPER PLUS SYSTEM B MODEL: 506VM- WWNYWYPIRIRI WEIGHT: 5,951 LBS. (EXISTING) SUPER PLUS SYSTEM A MODEL: 516VM- ZHZMAHHAPIRIRI WEIGHT: 6,146 L55. INTAKE LOUVER 18 "x18" OPEN'IN6Th (EXISTING) THERMA-STOR TANK /EIGHT: 1,450 LBS. ADDITIONAL (E) THERMA -STOR. TANK WEIGHT: 1,450 LBS: (EXISTING) (EXISTING) AIR. COOLED CONDENSER A AIR COOLED CONDENSER B MODEL: HLLV- V8410M. MODE: HLLV- VR412M WEIGHT: 2,500 LBS. WEIGHT: 2,880 LBS. (EXISTING) MECHANICAL HOUSE 19'6"x25'3"210'4 1 /4 "H. -52A- (E) MODEL: HIRP- 0484V5M DIMENSIONS: 35"x35' WEIGHT: 500 LBS. VENT -AXIA EXHAUST FAN 12 T/16 "x12 T/16' OPENING. REFRIGERATION CONTRACTOR TO PROVIDE (5) 24'6A. DRIP PANS TO EXCEED EQUIPMENT BY MINIMUM 6'. ON ALL SIDES. (EXISTING) MECHANICAL HOUSE 19'5225'3"x10'4 I /4 "H. SCAL 4 EXPIRED APR 1 a 2002 M2000-223 W O S