Permit M2000-250 - GRADING PACIFIC
M2000 -250 Grading Pacific 18338 Andover Pk W . Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 City of Tukwila Permit No: M2000 -250 Type: B -MECH Category: NRES Address: 18338 ANDOVER PK W Location: Parcel 4: 352304 -9018 Contractor License No: FIVESM *010JT TENANT OWNER CONTACT CONTRACTOR UMC Edition: 1997 The granting of or cancel the construction obtain this MECHANICAL PERMIT GRADING PACIFIC Phone: 18338 ANDOVER PK W, TUKWILA, WA 98188 LA PIANTA LTD PARTNERSHIP Phone: (206) 575 -3200 PO BOX 88050, TUKWILA WA 98138 ARTHUR ZAVALA Phone: 253- 833 -8284 3902 W VALLEY HY N; STE 200, AUBURN, WA 98001 FIVE STAR MECHANICAL Phone: 253- 833 -8284 3902 W VALLEY HY STE 200, AUBURN WA 98001 **************************,**************** ** * * * * * * * * * ** * * * * * * * * * * * * * * * * ** Permit Description: INSTALL OWNER SUPPLIED 6 1/4 TON ROOF -TOP GAS /ELEC AC PAYNE UNIT, WITH ALL RELATED DUCTWORK AND DIFFUSERS. ALSO INSTALL 2 BATHROOM FANS AND RELATED DUCTWORK. ** * * * * * * * * * * * * * * * ** .1k ** * * * * * * * * ** ** ** * * * * ** * ** * ** *fit * * ** *fit ** * * * * * * ** ** ** - � ir.iVifrl 1�P an -r/.•L r = i•y�rri��� ) Permit 4enter A horized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All pr • lsions of law and ordinances governing this work will be complied w th, whether specified herein or not. Valuation: Total Permit Fee: Print Name:_. -lii-P T_,a'u- Title: Status: ISSUED Issued: 11/28/2000 Expires: 05/27/2001 this permit does not p esume to give authority to violate ovisjons •f a other tate or local laws regulating work. I am authorized to sign for and (206) 431 -3670 4,500.00 77.94 Signature: _ __ Date: j This permit shall become null and void if the work is not commenced within 180 days from the date of Issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. - Address: 1 338 ANDOVER Pt W Suite: tenant: GRADING PACIFIC Type: B-MECH Parcel *: 352304-9018 bilikk*AkkAlk*khAkkkhkAAkkhkAkAAAIIIA*AA**AAkickkAAkkAkAkAlkAkAAAAAAArkAAAAAAAAAAAA Permit Conditions: I. Readily accessible access to roof mounted equipment is required, 2. Plumbing permits shall be obtained throueh the Seattle-King County Department of Public Health, Plumbing will be inspected by that agency. including all gas piping ,(296-4722). 3. Electrical permits' shall be obtained through the Washington State Division of * Labor and Industries and all electrical work will be inspected by that aoencv (248-6630). 4% 'No changes will bi made to the plans unless approved by the lEnginear and the Tukwila Building Division. 5. •All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (197 Edition) as amended, Uniform Mechanical Code (1997 Edition) and Washington State Energy Code (1997 Edition), 6. Validity of Permit. The issuance of a permit or approval of planS specifications, and computations shall not be con- strued to be a permit for, or an approval of any violation of any of the provisions of the building code or of any other ordinance of the iurisdiction, No permit presuming to give authority tu violate or cancel the provisions 0 thfs code shall be valid, 1. Manufacturers installation Instructions required on %ILO for the building inspectors review. O. "AFIRE DEPARTMENT CONDITIONSAAA 9, The attached set of plans have been reviewed by TI Fire • Prevention Bureau and are acceptable with the following concerns: 10, H.V.A.C. units rated .at reater than 2.000 ofm require auto-shutdown davices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance *1)00) 11, H.V.A.C, systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an ,automatic shutoff. Automatic shutoff shall be accomplished 0 interrupting the power source of the air-moving equipment upon detection of smoke in the main supplv-air duct served by such equipment. Smoke detectors seal! be labeled by an approved agency for air-duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 12. Duct smoke detectors shall be capable for being reset from the alarm panel. (City Ordinance 111900) 13. Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance *1900) CITY 01 TUKWILA Permit No: M2000-250 Status: ISSUED Applied: 11/08/2000 Issued: 11/28/2000 In areas that are not continuously occupied. automatic smoke detection shall be provided at each control unit(s) location to provide notification of fire at that location. (NFPA 1 -5,6) . The installation of wiring and equipment shall be in accordance with N.F.P.A. 70. Article 760, Fire Protective Signaling Systems, (NFPA 72-1- 5,5.4) 16. When the control panel is located inside a room. the door to the room shall have a sign with one inch letters which reads "Fire Alarm" or "Fire Alarm Control", (City Ordinance #1900) 17. Medicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 18, All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 19. Contact the Tui;wi la IFire Prevention Bureau to witness all required Inspections and tests, (UFC 10.503) (City Ordinance. 01900 , and 11901) 20. Duct detectrrs shall send a.suparvisory signal only upon activation. 21 Any overlooked hazardous c o n d i t i o n :and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22. The Plans were reviewed by .511 questions, please c a l l the tukwi 1a. Fire Prevention Bureau at (206)575-4407. I hereby;, certify that 1 have read these orrd i t i cans and w i l l comply ;. with them as outlined. All provision% of law and ordinances governlnq this work will be complied with, whether s p e c i f i e d herein or not. the granting of this permit oes of presume to g i v e authority to violate or cone 1 h pr v ons f env other work or local laws reouleti►ln co / r ;utt o o I`L per 'or manse of wort:. If you have any Name: .A: Project Name/Tenant: r 1 y r L , u ar.; LC Value f Mechanical Equippm.ent: Li S <2, Site Address : City Stat� ip : 51)3 5 /--ii,„,),,,,,,,,,,- P k to, Zv i,, A, Tax P reel Numb S ,a. 3 er: - Property Owner: / - z 4 trp Phone: ( ) Street Address: '• A is I / 1k . ' City State/Zip: ,. , ; ' ". d '' Fax #: ( ) Contractor: r 'A , / i_elk Ste- o ecttettfiri. Date: / w.• Phone: (2$ 3 ) g33 — 8,7 t9i/ Street Address: o i, a tit✓ City State /Zip: / J Fax #: (25 ) e33 _e6;20 Contact Person: r 01Av Phone: y ) Phone: ( ) Street Address: Gtr ) City State/Zip: Fax #: ( BUILDING OWNER OR AUTHORIZED AGENT' Signaturo: .,+ Date: / w.• Print name: 4(4ur"°�,,k (�, Phone: y ) Fax Fax 1: ( ,$ ) i Address: 510 / u iv t , 4 , Cr) L" u f" ! 6te. DA CITY OF TUh %ILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 II Paid 1 eJ it x4)000 - — FO' IF USE ONLY Project Number: Permit Number: M?ocO 2 Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. M ECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (10 BE FILLED OUT BY, APPLICANI •` ' " 3' Description of work to be done (please be specific): .� ►/ -, r vie 4 Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit In Lieu of Contractor Registration ". Building Owner /Authorized Agents if the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized Futter from the property owner authorizing the agent to submit this permit application and obtain the permit wilt be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 11/2/99 meth perndt.doc Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once, Date application accepted: Date application _mires: i i-eoo -8 Appli ti aken by: (initials) ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V,A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632,1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal 11/1/99 nuwpmt NOTE: Water heaters and vents are included in the Uniform Mechanical Code -- please include any water heaters or vents being Installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal SuI n,ill.if il'q lire' ;u sits Now Sin : le Famil Residence Heat loss calculations or Form H•6. Equipment specifications. Chan:e-out or re. lacement of exlating mechanical e9ulpmenf Narrativo of work to be done lncludin : modification to duct work. Installation of Gas Fire. lace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is In safe condition. NOTE: Water heaters and vents are included In the Uniform Mechanical Code — please Include any water, heaters or vents being Installed or replaced. : 7 7 **A**** ft ******** **** * *A** *A A ** ****************** A.".tY*6('t0k04.1.44., L *** .11** * ********************** jkif00111 OttkOort Y A01;0 whountt 1//,2e/vil 001:nuqr CHECC tichttiont 1 3EAR OCCAAW Lnt 11.1) • m441:r■, .MMO.M441114444.41. rtilt Nut M200v-260 rvpet a-MECH MCCOmNICw. PEllmfr rcei Not JV2i0.•1i A0Writuut Adjad mOUOVER 14 total itoutt - . VtLiqivmot - 77',4,i44 • lotto W.A.. Palto: 7 OAIMICet .#06***00.******0 iltle*********0**•********0************* #•*.tft C*111 `I.; 110 DattorIntion wmodot .0(1k0 0•A00 LHLCi. • NVOhLii 40V/422.100. mUCHONICkl. 000R69 WIOR1ANIW 0.44.111110WWVil.lt.I.WS VII.4.70.44 01"....WWA1711. . . . . . - - . .. . . .. . . s. 0190 /29 9710 TOTAL 77.94 • •,4 4. PERMIT NO.: PI Z. - Z9' MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 00002 Pre- construction ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation/Indoor AQC ❑ 00610 Chimney Installation/All Types ❑ 00700 Framing ❑ 01080 Woodstove (' 01090 Smoke Detector Shut Off ✓ 01100 Rough in Mechanical (v 01101 Mechanical Equipment/Controls 01102 Mechanical Pip/Duct Insul 01105 Underground Mech Rough -in 01115 Motor Inspection 1400 Fire Final 01800 Final Mechanical 04015 Special -Smoke Control System CONDITIONS (EK 0001 No changes to plans unless approved by Bldg ,_,/ Div l.7 0014 Readily accessible access to roof mounted equipment Ek .0016 Exposed insulation backing material 0019 All construction to be done in conformance � / w /approved plans L' 0002 Plumbing permits shall be obtained through King Co 027 Validity of Permit 0003 Electrical permits obtained through L & 1 0036 Manufacturers installation instructions required on site "BTU maximum allowed per 1997 WA State Energy Code" 0041 Ventilation is required for all new rooms & spaces "Fuel burning appliances "Appliances, which generate.,.." "Water heater shall be anchored..,." 8 Add ItionaI Conditions: TENANT NAME:---* C1T FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace/Burner to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended /Wall/Floor- mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooling Unit/System (qty) Boiler /Compressor to 3 HP /100,000 BTU (qty) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qty) over 50 HP/1,750,000 BTU (qty) Air Handling Unit to 10,000 cttn (qty) over 10,000 On (qty) Evaporative Cooler (qty) Ventilation Fan (qty) Ventilation System (qty) Hood (qty) Incinerator -- Domestic (qty) Incinerator — Comm /Ind (qty) Other Mechanical Equipment (qty) Other Mechanical Fee (enter $$) Add'l Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous Inspections (hrs) Add'l Plan Review (hrs) Plan Reviewer: Permit Tech: Date: Date: 11'1 S-CD 2 INVIMINIMMOIMMIPIP Projec ..--) V t Type of In ton: 1 , . A . dress: 40 A EP IP As A 4 1 (k W Date called: 12: .. 00 Special Instructions: Date wanted: a.m. v C i - a) I a Request St , ar 4.01 P *I COMMENTS: Inspector: Receipt No; Date: INSPECTION RECORL Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter 8Ivd, #100, Tukwila, WA 9818 12.0M PtftMit NO. (206)431-3670 pproved per applicable codes. , • „ Date: 0 $47.00 REINSPECTION FEE REQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter 8Ivd„ Suite 100, Call to schedule reins • action. Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: thorized Signature FINALAPP,FRM IANs c_ Rev, 2/19/98 'l. �.. "2." "'! Date T,F.D. Form F,P, 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206•57S•4404 • Fax: 206.575-4439 Project Name Address Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM - Retain current inspection schedule Needs shift inspection z/ Approved without correction notice Approved with correction notice issued Permit No. Steven M. Mullet, Mayor Thomas R Keefe, Fire Chief Suite # u ... Prajett; /' � b'AAo o C• � • of Ins A4. ► eel a A.•r•ss: D. colt': 0 5 ecial instructions: ��� CWT ( /0 t 4. Alf i • 1 1 r D t t • wa r ' ► ' A . Req. ter: la A Ph ► ne : IZ INSPEC1ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 a pproved per appficabld codes. COMMENTS: INSPECTION RECORC) Retain a copy with permit (206)431 -3670 Corrections required prior to approval. ED $47,00 REINSPECTION FEE REQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter Blvd„ Suite 100. CaII to schedule rains ►action, �� :;�i.::z =.i fS,'! ` �' :iii: �: .. s, ;..•.' `.�t�w.:�. 1 g LR1apsG' l4 kigh(galuDgj Dcn©0 CONSULTING ENGINEERS /CIVIL AND STRUCTURAL • STRUCTURAL DESIGN CALCULATIONS and DETAILS HVAC UNIT Building 734 18338 Andover Park West Tukwila, WA SEGGALE,,,BUS_, INES P.O. Box 88028 Tukwila, WA 98138 1519 West Valley Highway North/Suite 101 Post Office Box 836 /Auburn, WA 98071 253-833-7776 F'ax 253-939-2168 CnoJ, CONSULTING ENGINEERS/CIVIL AND STRUCTURAL R LAMA CgtiVi 1519 West Valley Highway North/Suite 101 /Aubum, WA 98001 Post Office Box 838/Aubutn,WA 98071 253. 8337778 Fax 253939.2188 tear t K UA* - LLKtr % i J0S 1.. W 1 '' '1 LL- 2S £e # SHEET NO 1 OF DATE DATE CALCULATED EY CHECKED SY SCALE ocxex 3 aPs } wtT csA r'i r nor r •t. 11 t+ M `lows + y s SUS td C..tw a3.O tors `c 4•040 tir t if& tretto4 4.0116141114. 4.w4.4g YHO:tC'::1 i Mai :i •. •+.:, :•.r hC.1 : +.F Gui ;EE'. ii} ? :54 9 4 } • nowt iguizdneeriCjp [ban CONSULTING ENGINEERSCML AND STRUCTURAL 1519 West Valley Highway North/Suite 101 /Aubum, WA 98001 Post Office Soot 838/Aubum,WA 98071 2538334778 Fax 253- 939.2188 I • J08 SHEET NO. CALCULATED BY 0 DATE N en/ era CHECKED BY DATE . SCALE • eAtlartoe >< tsT a1 !r 4• •ie,i 2.. CJ2.0_ 51 13, ^„� wag leo y M � S7 C.. 1.4. 3-■ + yr • 47ve` ga � ‘r 42..f' 12. fi hs a in C Pv.rt.‘.4 a — v,r4sk r S.4 D GPs of- 1r( t) sr( r) '.rum (b r). 4.4 17. d ►C. 1 �o •�- Ziarb 36 V Zo '�tf p +zr 4- Ict. (Zje) , K : � 2, ( �,�r� *, 4 4.) . 7 4fa' VS Pr 9Hait 4 3,F 3 .• 1 r?.." 1 1.404 12 vrC OF 4.77ty atIPCOrt NigMflneeri0110 fnnati CONSULTING ENGINEEFIS cML AND STRUCTURAL 1519 West Valley Highway Nort fSutte 101 /Auburn, WA 98001 Post Office Sox 839/Aubum,WA 98071 253.8334170 Fax 253939.2188 J0B SHEET NO OF DALE ri e-t/ 41-0 CALCULATED BY CHECKED BY SCALt3 7 DATe • Ifs k+wa Gov.. — >� Y VIE I fa( 6 /et) % 1 fit. 11,07 , at' )9051414%) Letto tAr alexik4 tAeaW f (IX- . f • . . . • UNIT 5800 CORNER WEIGHT (A) CORNER WEIGHT (B) CORNER WEIGHT (C) CORNER WEIGHT D) Lb Kg Lb Kg Lb Kg Lb Kg 038 140 MEM 105 NOM 29.5 048 imagiuml 106 48.1 giommat. 80 06 • �.s i:0►1 68.0 160 MAIM. : 072 MIME 165.0 ( raimmi 200 90.7 EMI 29.0 • A CONNECTION SIZES 1 As Dia. (27) Field Power Supply Hole B W•14 NPT Condensate Drain C 'h'04 NPT Gas Connection 0'•1 3/4' 11401 34 (1 14 ) c00w10 ' 0' AcCE550a, H000 'MIA 0•.11 s, /• P. 1 0 51 e/ /./ice 1'• /1' IC /I ..�.�..�.�. 3' •, lip' 1/11.81 CONOCN110 COIL (``14 se ag 1fll1' II CON11(1300 ACC111 COV107 0'•7 114' (1941 t0 1115' (774.6 DIMENSIONAL DRAWING — 580D03b -u72 0 (103.2) 2'•1 1116' 1632.31 rn.TtR ACCE6a PANEL (7mt4c6VAWAY PLUMS) 1 0'4 li/t6' (144,31 RIGHT SI 1 110. C01+O(I4AIC OAAIN REAR 0.JVD0011 Atr1 riLtcUtCONONIt10 ACC111 PA14L 3'4 t n0' ��., (6371 0'.1 `(1141 0'•1011/11' ;Sale %AWN 1 • 1 ' 1 1 314' 0'•6 7/10' (1301 CON100. 110x *CCCO$ 041411. 1,•1 1 1V*P00A100 COIL .0' {41! -0'4 3/10' (99, '.0 1/1 (306) 0'•, 11/15 (1072) 5 31 ! FCIRKUFT TRUCK SLATS ( »6.2 0'4 3/0' OVRIIZA 4cCE7,5 1100.01 0'.3 t5�1 IA Pu:EL FRONT 1'1 a °LaCE51 , 4 0'•0 3/0' (10) .0'4 7/16 {011 NOTES: 1. Dimensions in ( ) are in millimeters. 2. Center of gravity, 3, * Direction of airflow, 4, On vertical discharge units, ductwork to be attached to accessory roof curb only. For horizontal discharge unitS, fleld•suppflad flanges should be attached to horizontal discharge openings. and all duct• work should be attached to the fla s. 5. Minimum clearance (local codes or urisdlctton may prevail): L Between unit flue side and !tibia surfaces, 36 Incites. b. Bottom' of unit to combustible surfaces (when not using curb) 1 inch, Bottom of base rail to combustible surfaces (when not us• Ing curb) 0 inches. c, Condenser coif, for proper airflow, 38 in, one side. 121n, the other. The side getting the greater clearance Is optional. d. Overheat, 60 in. to assure proper condenser fan operation. 0. Between units, control box side, 42 In, per NEC (National Electri. cal Coda). 1. Between unit and ungrounded surfaces, control box side, 36 in. per NEC, g, Between unit and block or comfit' walls end other grounded suf. laces, control box skis, 42 In, per NEC, h. Hortzonlal supply and 'alum end, 0 Itches. 8. With the exception of the clearance 101 the condoner wit and com• busOon !de as stated In Note 5a, b, and c, a removable fence or barricade NOM! 110 clestanco. 7, Units may be Inhaled on combustible . floors made from wood or , Class A. 8, or C r0o1 covering material If sot on buerail. 1'•4 l 7/et CONrIIOL WIAI (4161 1 ..,.0011140 '0' 2'•9 5/16' 10 80110N QF INII L.L 0'.4 9/16' (115.01 M 410 13/1' RIGHT SIDE 4(0 CO040 'C' A OVC' 146.7 ; 7116 1.10 VIEW HOL1 ' QF 0,5E aAI1. ^ ---- -- 7' •5 3/16 +0' -7 9 110461 1653 LEFT SIDE 211 p V N A . hi "16 ►6VE Hooc 3 Modes 579/580 as heating /electric roofing units ' are designed to deliver optimum performance and reliability in a commerci'pl unit, Every unit is factory run tested prier to 'shipment to ensure reliable installation. The 579/580 are designed to be field•convertibte from vertical supply/return to horizontal supply/ return (180.300 units require accessory horizontal supply curb), making them easily adaptable to a wide variety of new construction and replacement applications, For vertical supply /return Jobs the ductwork can be connected directly to the root curb, allowing ductwork to be completed before the unit arrives at the job cote, The foltowinb factory =lnatalIed options are available: economizers, manual dampers, controls upgrade packages, filter access door panels, condenser coil grilles and higher static alternate evaporator Ian motors STANDARD FEATURES • Prowirod, prapiped and prechargod for minimum installation expanse • Convertible unit (180300 units require accessory horizontal supply curb) • All units comply with ASHRAE Standard 82 • Internal return• air filters • Low profile, compact size permits easy shipment, rigging and installation • Every unit fa run•testod at the factory In both the cooling and heating mode • Dual compressors and dual refrigeration circuits (090150 and 216.300) • Power, control and gas connections made on same side of unit • Commercial strength base rails for easy rigging and lifting • Prapainted corrosion resistant baked enamel finish on inside and outside of cabinet • Cooling operation at outdoor ambient temperatures as low as 25 F Compressor vibration isolation mounting • Low =voltage terminal blocks for easy wiring connections • Induced draft combustion • Aluminized corrosion resistant tubular heat exchangers LIMITED STANDARD WARRANTY • One -year parts only on all parts • Additional second through fifth year on compressor, no labor (036.180) • Additional second through fifth year on heat exchanger, no labor SUBMITTAL DATA Job Name e6.4 . Vn.c:.:; Architect — • Engineer , Franidirk E1ri irle rirrj Contractor five. '1 s a l 4. Unit Designation • UNIT DATA Unit Model No: - 580CLV072150 Units Volts•Phas _ Operating Voltage Range 414 408 Minimum Circuit Amps 16.6 Maximum Overcurrent Protection (Fuse or HACR Clrult Breaker) Unit Full Load Amps 16 Operating Weight 600 1}a8. COOLING PERFORMANCE Outdoor Ambient Design Temp 85 'F Total Capacity (at design) 78 500 ., Btuh Sensible Capacity (at design) 56 400 Btuh Compressor kW • kW .......... .... . Indoor Fan HP 2 0 H.P. (2.4 B.H.P.) External Static Pressure njn" Airflow at Indoor Coil 2400 FP/Min Entering Air Temp 80 'F OB Entering Air Temp °F WO Leaving Air Temp — 'F DB Leaving Air Temp — °F WE Energy Efficiency Ratio (EER/SEER) _. 8.9 •A OAS HEATING PERFORMANCE Input 150 000 Btuh Output 120.QQ,Q, i3tuh AFUE 80 Wamock Herse , 00.300 HEATING & COOLING SUBMITTAL Model 579E/579F/580D Sizes 036 thru 300 COMMERCIAL ROOFTOP GAS HEATING/ ELECTRIC COOLING UNITS 6uroUC AA1 zIaaw 50 AF, 640044 NM/ - 8- 200 PERMIT CENTER 036.120 036 =20 ACCESSORIES Factory installed: 17arrrizer/1a'. relief, freeze stet, high arci kw moire Switches 0* I0 AR, SWWWv4 360 UNIT 580D CORNER WEIGHT (A) CORNER WEIGHT (B) CORNER WEIGHT (C) CORNER WEIGHT (0) Lb Kg Lb Kg Lb Kg Lb Kg 036 140 63.5 105 47.6 159 72.1 56 25.4 048 142 64.4 106 48.1 162 73.5 60 27.2 06 150 68.0 115 52.2 160 72.6 65 29.5 072 165 165.0 136 61.7 200 90.7 64 29.0 • EVAPORATQRFAN T AC O E s$ PANEL •3 5019 (91.0! O,.g 2,t' E ...., (1.441 Out IOE 0 •4*41 SIDE CO44ta01, fil e:t55 i ,, s .419.tt REAR ( ill uLtt0.OsitM $Ct166 e►htl )'.1 t!j' Ilia Si ti0■4thiata COIL 1 •3 .lJJit s�,* 0'•7 I /A' (1941 r0 U015' h 27A.611 k.11 410. 'IMENSIONAL DRAWING -- 580003b-u. Ie1 ;� 000 000 At0a t011 I 1 O)4, � i i a0 0rt,! IC( 4.0•.1 1 !11 1 , 'View 4.4... (A9 ',11 060.1 1 f t 0'•) 1110 ! lQl 044 4tC(5A PANCf L� FONT C0 4LA 0' j'.11' 11110' 10061 17 3/8 / FQRKLiFTTRUCKSLOTS 3'8' NANO ACCIi55 :199.91 04r.E1. FRONT 0 t /t6 (103.21 4. On vertical discharge units, ductwork to be attached to accessory roof curb only. r F lontdnfat d +SCfla<IQ0 }An +l, fietd•suppned flanges should be attache o oiiib' iT discharge and all duct. work should be attached to the flanges. 5. Minimum Clearance (local codes or jurisdiction may prevail): a. Between unit, flue Side and Combustible surfaces, 36 inches. b. Bottom of unit to combustible surfaces (when not using curb) 1 inch, Bottom of base rail to combuelibte 5uttaCes (when not u5 mg Curb) 0 inches. C. Condenser coil, for proper airflow, 36 in. one side, 12 in. the other ina Side getting the greater Clearance is optional. d. Overhead. 60 in. to 'sure proper condenser fan operation. 0. Between units, COnftol box tide, 42 In. per NEC (National E leCiri• cal Code), 1, Bpeetween r NEC. unit and ungrounded surfaces, control box side. 36 al g. Between unit and block or Concrete walls and Other gt0undeo tor latest, control box side, 42 in, per NEC h. Horitonlal supply and return and, 0 inches. . With the exception Of the clearance for the COnMMMOet 0011 and Com• bu0lion side as stated in Nolo 6A, b, and c, a removable fence or barricade requires no clearance. 7, Units may be installed On Combustible lioora made from woo .o �lis• , r / 2 . Clue A, B, Or C tool Obviating material f set on baaerall. 16 ))1 rr41 NOM r ( COhOtedAt( SINNINIM M. At 6 iI0I6' 110 " 2'•1 rr ,t6' (632.51 I0'•b lase. (144.31 OIIAI RI GHT SIDE ACCtS9C4r CCCa0.11/ 11 MO00 1111110:11.111.1i..10 MO. CUT00011 Aa1 FILTER ACCESS PANEL 04010WAWAY FILTERS) /10' r0 ( O (0111 I i( /if' 0 1/4'014 "i 4 9 1.4CE51 1y0P11 Alx" 00(441'16 Y( 1 )!4' �tI 0'•1 70x6' OVA 1611(11 .,,ee 7' 16'.°'.004(4 •t' 0'•0 )/0' 1101 ActtSSOrtr Fb00 F +lttr t)i5.i(A t t�t6 NOTES: 1. Dimensions in ( J are in millimeters. 2. 0 Canter of gravity. 3. F 2 Direction Of airflow. )!d' i4 Oi .I,�- toAat, .61 0'.10 title' 1j /01 2 •e 5116 1046. 8011o$ 0 u ' u n i t 0 .4 9/15:j (115. tit 4410 RIGHT SIDE the Mallet. Mao 4 . 06:51"' 6 1CO V;r •*Ol( ti 1.A �4 F04 IYa.� CC*4(0 . r11Mr A ' abTtCM OF 845E x411 D' 5 3/16' !VP (1046) 0'.2 9/ +65) LEFT SIDE V 1.12±.1,1 ()051 Ot 1.,6. 1 (643ff F1.LE 1.000 3 Bs CONNECTION SIZES A 1'viA' Dia. (27) Field Power Supply Hole B 3/4%14 NPT Condensate Drain C */ •14 NPT Gas Connection • EVAPORATQRFAN T AC O E s$ PANEL •3 5019 (91.0! O,.g 2,t' E ...., (1.441 Out IOE 0 •4*41 SIDE CO44ta01, fil e:t55 i ,, s .419.tt REAR ( ill uLtt0.OsitM $Ct166 e►htl )'.1 t!j' Ilia Si ti0■4thiata COIL 1 •3 .lJJit s�,* 0'•7 I /A' (1941 r0 U015' h 27A.611 k.11 410. 'IMENSIONAL DRAWING -- 580003b-u. Ie1 ;� 000 000 At0a t011 I 1 O)4, � i i a0 0rt,! IC( 4.0•.1 1 !11 1 , 'View 4.4... (A9 ',11 060.1 1 f t 0'•) 1110 ! lQl 044 4tC(5A PANCf L� FONT C0 4LA 0' j'.11' 11110' 10061 17 3/8 / FQRKLiFTTRUCKSLOTS 3'8' NANO ACCIi55 :199.91 04r.E1. FRONT 0 t /t6 (103.21 4. On vertical discharge units, ductwork to be attached to accessory roof curb only. r F lontdnfat d +SCfla<IQ0 }An +l, fietd•suppned flanges should be attache o oiiib' iT discharge and all duct. work should be attached to the flanges. 5. Minimum Clearance (local codes or jurisdiction may prevail): a. Between unit, flue Side and Combustible surfaces, 36 inches. b. Bottom of unit to combustible surfaces (when not using curb) 1 inch, Bottom of base rail to combuelibte 5uttaCes (when not u5 mg Curb) 0 inches. C. Condenser coil, for proper airflow, 36 in. one side, 12 in. the other ina Side getting the greater Clearance is optional. d. Overhead. 60 in. to 'sure proper condenser fan operation. 0. Between units, COnftol box tide, 42 In. per NEC (National E leCiri• cal Code), 1, Bpeetween r NEC. unit and ungrounded surfaces, control box side. 36 al g. Between unit and block or Concrete walls and Other gt0undeo tor latest, control box side, 42 in, per NEC h. Horitonlal supply and return and, 0 inches. . With the exception Of the clearance for the COnMMMOet 0011 and Com• bu0lion side as stated in Nolo 6A, b, and c, a removable fence or barricade requires no clearance. 7, Units may be installed On Combustible lioora made from woo .o �lis• , r / 2 . Clue A, B, Or C tool Obviating material f set on baaerall. 16 ))1 rr41 NOM r ( COhOtedAt( SINNINIM M. At 6 iI0I6' 110 " 2'•1 rr ,t6' (632.51 I0'•b lase. (144.31 OIIAI RI GHT SIDE ACCtS9C4r CCCa0.11/ 11 MO00 1111110:11.111.1i..10 MO. CUT00011 Aa1 FILTER ACCESS PANEL 04010WAWAY FILTERS) /10' r0 ( O (0111 I i( /if' 0 1/4'014 "i 4 9 1.4CE51 1y0P11 Alx" 00(441'16 Y( 1 )!4' �tI 0'•1 70x6' OVA 1611(11 .,,ee 7' 16'.°'.004(4 •t' 0'•0 )/0' 1101 ActtSSOrtr Fb00 F +lttr t)i5.i(A t t�t6 NOTES: 1. Dimensions in ( J are in millimeters. 2. 0 Canter of gravity. 3. F 2 Direction Of airflow. )!d' i4 Oi .I,�- toAat, .61 0'.10 title' 1j /01 2 •e 5116 1046. 8011o$ 0 u ' u n i t 0 .4 9/15:j (115. tit 4410 RIGHT SIDE the Mallet. Mao 4 . 06:51"' 6 1CO V;r •*Ol( ti 1.A �4 F04 IYa.� CC*4(0 . r11Mr A ' abTtCM OF 845E x411 D' 5 3/16' !VP (1046) 0'.2 9/ +65) LEFT SIDE V 1.12±.1,1 ()051 Ot 1.,6. 1 (643ff F1.LE 1.000 3 Bs 0537 Gorton Micro Moll Part Numb Knocked -down Roo!curb SDP P/N .rpoc!bonbons (In Inchon) BDP Units A 0537-0101 , 00020.201 5000, 65 80, SAOC 038.072 14 24 0537 -0300 N/A MicroMetl Knocked -down Roofcurbs for BDP 580C, 558C, 548C 036 - 072 units 1 3/4" Dock pans Optional aorvico plates (3 provided) 0111•11111111M MOM* FORM NO. 1475 -2P SUBMITTED TO COMPANY: DRAWN BY: D.r. JOB NAME: EQUIPMENT: OTEO: FEATURES ` Mitorod top corners and pro pundlod assembly bolos. • Roolourb sides and onds we l Oga. galvaniwd stool, (,050 min.) • Oaskodng package provided, ' Full porlmolor wood nailer, Assembly hardwelro Included for field assembly. NOTES: 1.) Pitched curbs and tailor curbs aro avallabio, Contact factory. - 2,) Attach ductwork to roolcurb. Flanges of duct rust on top of curb, 3,) Roofcurbs are marked with the OOP part number, Optional Service PlatQs 0537 -0101, 0300 0815 -0537 Micro Met! Port Number ervce ' o e Port Number 14" or 24" 1 3/4' Alt, drain holo Mitorod top corners 14 3/16' 37 3/16 1 3/4- I • . • 1 " CROSS SECTION OF CURB (3)'Inaulatod deck pans 1' 1,51b, density Insulation, glued in place, 4 IMPORTANT NOTE Standard curbs do not include service holes thru wood nailer. If they are required, specify on order. eft. eft. 67 3/8" Part Number: 0537 -0101 & 0300 typ, Section AA ig Nu QuieTTest Combination MODEL§raMtar90 & QT110 ltiSTAL I ATiON i19 A NOW CONSTRUCTION $(TE MOUNTING THE HOUSING 1. Refer to Figure 3, Insert mounting brackets at each end of housing. 2. Place long side of housing parallel to ceiling joist. Position housing in desired location. Make sure housing flange is even with the planned finished ceiling. 3. Use screws or nails (not provided) to secure mounting brackets to ceiling joists. 4. Refer to Figure 1, Use 4" round duct to discharge the ventilator to the outside. IMPORTANT: Be sure nothing obstructs the discharge of the ventilator. Make sure that insulation does not get Into the duct work or into the fan. FILE GOP �'- ._ ----= royals are f ^ \ s lt o I understand that the Pia. ► C. h a eck p d r± to �-rrwr. ^'� �`�'�" i\i§ A INSTRUCTIONS REAL? & SAVE THESE INSTRUCTIONS! CITY OF TUKWILA NOV - 8 2000 PERMIT CEN SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT. IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. 0 you have questions, contact the manufacturer. B, Before servicing or cleaning unit, switch power oft at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. CAUTION: For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. INSTALLAT_EON_ NSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, Including fire•rated construction, 0, Sufficient air is needed for proper combustion and exhausting of gases through tho flue (chimney) of fuel burning equipment to prevent back drafting, Follow the healing equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Healing, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities, D. Ducted fans must always be vented to the outdoors. E, It this unit is to bo Installed over a tub or shower, It must be marked as appropriate for the application. F. NEVER place a switch whore it can bo reached from a tub or shower, • Do not Install In a ceiling Insulated to a value greater than R40. • Suitable for use with solid state speed controls, Use Wone Model VS•64, • Not for use In kitchens, EAT .REE. TS When installing the Ventilator in a new construction alto, install housing during the rough•in construction of the building, The blower unit and grille should be installed after the finished ceiling is in place, To install a ventilator in an existing building requires an accessible area (attic or crawl space) above the planned location. rEP 4' DIAMETER DUCT (CONDUIT DE 4 PO DE DIAMETEE) 90' ELBOW N NA (COUDE A 90') ROOF CAP (COUVERCLE E TOIT) 1 1 1 , WALL CAP (COUVERCLE MURAL) CEILBI INSTALLATION (POSE AU PLAFOND) FIGURE 1 JUNCTION BOX (BOITE DE JONCTION) STANDARD WALL SWITCH (INTERRUPTEUR MURAL STANDARD) r — 120v AC, 60 Hs HOUSE POWER (COURANT LECTRIOUE) GREEN GROUND SCREW (VIS VERTE DE MIS A LA TERRE) 120v AC SWITCH BOX (BOITIER D'INTERRUPTEUR) EARTF( GROUND (MISE A LA TERRE) FiGURE 2 5. Connect house power wire to standard toggle switch or use a NuTone timer switch (sold separately.) NOTE: BE SURE VENTILATOR AND SWITCH ARE PROPERLY GROUNDED. ALL WIRING MUST COMPLY WiTH LOCAL ELECTRICAL CODES, WIRING Refer Figure 2. PREPARATION 1. Run 120v AC house power wiring (with ground) through 1. Remove blower /power unit assembly from housing: switch box to junction box in ventilator housing, A, If necessary, unplug power unit. 2, Remove ventilator junction box cover, B. Loosen three (3) mounting screws. 3, Connect house power wires to ventilator wires: black to C. Slide unit back to free it from mounting screws, black; white to white. Connect ground wire to green D. Remove unit and set aside until needed. ground screw. 2. Remove one of the wiring knockouts from housing. 4. Replace junction box cover. POWER /BLOWER UNIT INSTALLATION 1. Plug motor into socket in housing's junction box. 2. Position power unit mounting plate over mounting screws in housing. 3. Slide unit forward until the gasket fits firmly against discharge opening in housing and mounting screws are seated in narrow end of keyhole slots. 4. Refer to Figure 3. Securely tighten screws, GRILLE INSTALLATION 1. Refer to Figure 3. Snap grille mounting springs' center loop into notched bosses on the back of grille. 2. Place grille mounting springs into slots in power unit mounting plate. 3. Press grille firmly into place against the ceiling. INSTALLATION IN EXISTING CONSTRUCTION Installing the ventilator in an existing house requires an accessible area (attic or crawl space) above the planned installation location. Review "INSTALLATION iN A NEW CONSTRUCTION" and follow all instructions which apply to your installation, Location — locate ventilator parallel to a ceiling joist. Wiring and Ducting — plan ducting and wiring before proceeding with Installation. Refer to Figure 2 for wiring and Figure 1 for ducting. CAUTION: Chock area above planned Installation to be sure that: 1. Ducting can be installed. 2. Wiring can be run to the planned location. 3. No wiring or other obstructions might Interfere with installation, INSTALLATION FROM ACCESSIBLE AREA ABOVE 1, From bolow, drill a small holo in coiling at Rho plannod location, Stick clothos hanger through holo to help locate it. 2, Locate holo in attic or crawl spaco, 3, In attic or crawl spaco, mark coiling for cutout by using iho housing as a tomplato. Tho long sldo of cutout must bo parallel to coiling joist. 4. Mako cutout along markod lino. NOTE: If ceiling le plaster, cutout should be made from below to avoid chipping plaster, 5. Install housing, connect wiring and ducting, Install power unit/blowor assombly and Install grille, HOUSING MOUNTING SCREWS I i MOUNTING SPRING I NOTCHED BOSS MOUNTING SPRING " DISCHI ROE OPENING ' WJNO KNOCKOUT MOUNTING BRACKET POWER UNIT MOUNTING PLATE GRILLE FIGURE 3 Product specifications subject to change without notice. Nubne Madison and Red Bank Roads, Cincinnati, Ohio 45227.1599 Printed in U.S.A., Rev. 7/99, Part No. 84608 flu One Year Limited Warranty WARRANTY OWNER: Nutone warrants to the original consumer purchaser of its prcdu.ts that such products will be free from defects in materials or workmanship fora period of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED. INCLUDING, BUT NOT LIMtte0 TO, IMPLIED WARRANTIES OF MERCHAtfTAOILITY OR FITNESS FOR A PARTICULAR PURPOSE. During Oat one year potted, Nutone wilt. at ltS option, repair or replace, *grout charge, any product or part which is fouxf to be defect ve under normal use and service THIS V/ARflANTY DOES NOT EXTEND TO f LUOnt SCENt WAp STARTERS OH TURES, FILTERS. DUCT, ROOF CAPS. WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does nod Sewn (a) normal ma!Morianci and service or (b) any products or pans which have been tiotraeol o mitasa, nellagenea, atOderd, yt mainlerimed or repair (other than by Nut ono), feisty tn4I atatiOn dX Installation contrary Id t C Yti 11erid9d installatinn intlrttElitlni Ths duration of any irti isod warranty 14 tamed Id trio Ent♦ Wit period as 4ha+f_d for fh@ @i$ire44 warta1dy. Sarno autos rid not Any ttngatirin 6n Now long an tfroAod *enmity IA4f4, at) tit MOO amvtakal may nal afi(Itr kr yriu NUT040'0 OBLIGATION TO REPAIR OR REPLACE, AT NUTONI'0 OPTION, SHALL OE THE PURCHASER'S SOLE AND EXCLUSIVE RIMEDY UNDER THIS WARRANTY, NUTONE SHALL NOT OE LADLE FOR INCIOINTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR iN CONNECTION WITH PRODUCT USE OR PERFORMANCE, Skid@ 414104 ifs rnc4 Aka IN ••cduno n a Whaation of tfl€ t :al a 663 luenliai danrfgoo. 40 WiI abUro knot /Won me out/Akin may not taffy in you TW4 *manly tyros ydu Stook 1 rkdrd4, and yue miry flat) hay* Mho NW. which vfiry Mimi 4tale id 41.414 IN* wana•ity tot 144todaa as ptnt)t wattaness WARRANTY SERVICE; To quality for warranty wale*, you must (a) nifty Nu Tom M the address staled below or talophone 11004U' 0601, (b) give the model mambo end pal Identification and (a) describe the nature o1 any detect In the product or pert Al 1M Uma of requesting warranty saris, you must present eviderice o1 tta original purchase date. Pita of instalation Wader a Instaaei Model No. and Preritra Pesei pion IF YOU NEED ASSISTANCE OR SERVICE; For the Wilton of your nomad Ntjrpne indep0nd0M AuUioni t iiervic0 Center: Residents 01 the contiguous United Blotto NI Free 1- 000 -547 @fill Please be prepared to provide: Product model number • Date and Proof of purchase • The nature of the difficulty Resident• of Alaska or Hawaii should write lo: NuTono Inc. Ann: Department of National field Service. Madison and Rod Rank Roads, Cincinnati Gino 45227.1599 Residents 01 Canada should write to; NuTone Canada Inc., 6300 Tomken Road.Mississauga, pntano, Canada L5T 1N2. Rev. 4/99 POWER /BLOWER UNIT INSTALLATION 1. Plug motor into socket in housing's junction box. 2. Position power unit mounting plate over mounting screws in housing. 3. Slide unit forward until the gasket fits firmly against discharge opening in housing and mounting screws are seated in narrow end of keyhole slots. 4. Refer to Figure 3. Securely tighten screws, GRILLE INSTALLATION 1. Refer to Figure 3. Snap grille mounting springs' center loop into notched bosses on the back of grille. 2. Place grille mounting springs into slots in power unit mounting plate. 3. Press grille firmly into place against the ceiling. INSTALLATION IN EXISTING CONSTRUCTION Installing the ventilator in an existing house requires an accessible area (attic or crawl space) above the planned installation location. Review "INSTALLATION iN A NEW CONSTRUCTION" and follow all instructions which apply to your installation, Location — locate ventilator parallel to a ceiling joist. Wiring and Ducting — plan ducting and wiring before proceeding with Installation. Refer to Figure 2 for wiring and Figure 1 for ducting. CAUTION: Chock area above planned Installation to be sure that: 1. Ducting can be installed. 2. Wiring can be run to the planned location. 3. No wiring or other obstructions might Interfere with installation, INSTALLATION FROM ACCESSIBLE AREA ABOVE 1, From bolow, drill a small holo in coiling at Rho plannod location, Stick clothos hanger through holo to help locate it. 2, Locate holo in attic or crawl spaco, 3, In attic or crawl spaco, mark coiling for cutout by using iho housing as a tomplato. Tho long sldo of cutout must bo parallel to coiling joist. 4. Mako cutout along markod lino. NOTE: If ceiling le plaster, cutout should be made from below to avoid chipping plaster, 5. Install housing, connect wiring and ducting, Install power unit/blowor assombly and Install grille, HOUSING MOUNTING SCREWS I i MOUNTING SPRING I NOTCHED BOSS MOUNTING SPRING " DISCHI ROE OPENING ' WJNO KNOCKOUT MOUNTING BRACKET POWER UNIT MOUNTING PLATE GRILLE FIGURE 3 Product specifications subject to change without notice. Nubne Madison and Red Bank Roads, Cincinnati, Ohio 45227.1599 Printed in U.S.A., Rev. 7/99, Part No. 84608 Combinaison QuielTest MODE QT80, QT90 et QT110 Le ventilateur comprend uri boitier, des supports de montage, un couvercle de boite de Jonction, un ensemble moteur /ventilateur (moteur, roue, plaque de montage) et une grille. • Pour utilisation avec les commandos de vitesse electroniques. Utiliser le models VS -64 de NuTone. • Ne pas utiliser dans les cuisines. • Le ventilateur ne dolt pas etre installs dans un plafond a isolation thermlque superieure a R -40. IMPORTANTES DIRECTIVES DE SECURITE AVERT1SSEMENT: POUR REDUIRE LES RISOUES D'INCENDIE, DE CHOC ttLECTRIQUE OU DE BLESSURES, RESPECTER CE QUI SUiT: A. Utiliser cet appareil seutoment pour les fins prevues par le fabricant. Pour toute question, communiquor avec le fabricant. B, Avant de faire I'entretien ou le nettoyago de ('apparel,, couper le courant au tableau do distribution pour eviler quo le courant no salt romis accidontollemont, Lorsquo vows no pouvez vorrouiller l'interrupteur, placez un avortissomont clairomont visiblo, par exempt() uno dtiquotto, sur to tableau do distribution. ATTENTION: Pour ventilation generalo seamen!, No pee utiliser pour dvacuor dos vapours ou dos matibros dangorousos ou explosives. DIRECTIVES D' INSTALLATION AVERT1SSEMENT: POUR R DUIRE LES RISOUES D'INCENDIE, DE CHOC ELECTRIQUE OU DE BLESSURES, RESPECTER CE QUI SUIT: A. Los iravaux d'Instailation el d'bleclricite doivont etre confiQa A dos porsonnos quatifieos, conformomont aux normos of aux codas on viguour, notomment on co qui concorno los normos do protection contra los Incondios. B. Pour bvitor lob rotouro d'air, los apparolls do chauflago doivont avoir suffisammont d'air pour assurer uno combustion of une Avacuallon appropribos dos gaz, Suivro los directives du fabricant do I'appareil do chauffago ainsi quo los normos do adcurite bdictdos par des organisms comma la National Fire Protection Association (NFPA), ('American Society for Heating, Refrigeration and Air Conditioning Engineers ou los organismes de reglamentation lacaux. C. Lorsque vous percoz lop murs of plafonds, eviler d'endommagor los fits electriquep et les autro8 canalisations, D. Lea ventilatours dotes de tuyau doivont toujoura 8tre raccordes A I'exlerieur, E. SI cot apparel, dolt 8tre installs au•dessus d'un bain ou d'une cabin° do douche, it dolt dire identifie comma convenant A une toile installation. F. NE JAMAIS placer un interrupteur A Ia porteo dune personne qui se trouverait dans le bain ou Ia douche. POUR OBTENIR LES MEILLEURS RESULTATS Pour poser le ventilateur dans les nouvelles constructions, installer le boitier au stade de Ia construction brute de I'immeuble, Le ventilateur proprement dit et Ia grille seront poses apes Ia miss en place du plafond fini. Pour poser un ventilateur dans un immeuble constrult, it taut un endroit accessible (grenier ou vide sanitaire) au- dessus de ('emplacement prevu. POSE DANS UNE NOUVELLE CONSTRUCTION PREPARATION 1. Retirer ('ensemble ventilateur /moteur de son bottler: A. Si necessaire, debrancher le moteur. B. Desserrer les trois (3) vis de montage. INSTRUCTIONS D'INSTALLATION LIRE ET CONSERVER CES INSTRUCTIONS C. Deplacer le moteur vers I'arriere pour le libeler des vis de montage. D. Sortir le moteur et le mettre de cote pour plus tard. 2. Enlever une des debouchures de raccordement de bottler. MONTAGE DU BOITIER 1. Voir la Figure 3. Inserer les pattes de montage a cheque extremite du boitier. 2. Placer le cote long du battier parallele a is poutre du plafond. Mettre le bottler en position a ('emplacement desire. Verifier quo le collet du bottler soit de niveau avec la position do finition du plafond. 3. Utiliser des vis ou des pointes (pas fournies) pour installer les pattes de support sur les poutres du plafond. 4. Volr Figure 1. Utiliser un conduit rond de 4 po comma decharge exterieure pour le ventilateur. IMPORTANT: S'asouror quo rfen n'obstruo la decharge do ventilateur, et quo I'isolant penetre pas dans los conduits ni dans lo vontilateur. RACCORDEMENT ELECTRIQUE Voir Figure 2. 1. Achominor le fit d'aiimontation eteclrique de 120v CA (avec terre) travors la boito d'intorruptour et jusqu'a la bolto do Jonction dans , le boitier du vontilateur. 2. Retirer lo couvercio do la bolto do Jonction du vontilateur. 3, Raccordor los fits d'alimontation eloctriquo aux fits du vontilatour • noir h noir et blanc a btanc. Raccordor 1e 11I do miso A In terre d la vis vorto, 4, Replacer lo couvorcio do la bone do jonction. 5, Raccordor lo fil d'elimontclion bloctriquo A un intorruptour standard b bascule dans in bone d'intorruptour, ou utiliser uno minutorio Ntlfono do 00 minutes ou 16 minutes, REMARQUE: LE VENTILATEUR ET LINTERRUPTEUR DOIVENT ETRE MIS CORRECTEMENT A LA TERRE, ET TOUS LES RACCORDS DOIVENT LTRE CONFORMES AUX CODES D'ELECTRICITE LOCAUX. POSE DE L'ENSEMBLE MOTEURNENTILATEUR 1. Urnncher lo motour dans la douillo do In boito do jonction du bottior. 2. Placer lo plaque de montage du motour par•dossus los vis do montage, dans le bollior. 3, Deplacer Ions ©mblo vors ('avant jusqu'A co quo to joint so cote bion en place contra I'ouvorturo de decharge du bottler, el que les vis do montage soient insere os dans I'axtremit8 etroite dos lentos en forme de lrou do cle, 4, Voir Figure 3. Bien sarrer les vis, POSE DE LA GRILLE 1. Voir Figure 3. Inserer Is boucle contralti dos ressorts de montage de la grille dans les bossages A rainures au dos de Ia jrille. 2. Placer les ressorts de montage de la grille dans les fences de Ia plaque de montage du motour. 3. Presser la grille fermement pour la maitre en place au plafond. POSE DANS LES IMMEUBLES CONSTRUITS II faut avoir une one d'accas (faux grenier) au dessus de ('emplacement desire pour installer le ventilateur dans une maison existante. Lire les instructions "POSE DANS UNE NOUVBELLE CONSTRUCTION" et suivre toutes les instructions applicables au cas particulier. Emplacement — placer le ventilateur pros dune de plafond. Raccords et conduits — Prevoir I'acheminement des conduits et des raccords electriques avant la pose. Voir Figure 2 pour les raccords et Figure 1 pour les conduits. ATTENTION: Examiner I'espace au- dessus de I'endrolt prevu pour la pose, afin de verifier si: 1. On peut installer les conduits ou s'il y a assez d'espace pour une ventilation appropriate. 2. On peut acheminer les dils electriques jusqu'a l'endrolt pr5vu. 3.11 n'y a pas de fits ni d'autres obstacles pouvant goner ('installation. POSE A PARTIR D'UN ENDROIT ACCESSIBLE AU- DESSUS 1. Par en dessous, percer un trou de petite dans le plafond, I'endroit provu. Inserer un cintre dans le trou comme moyen de rep5rage. 2. Paperer le trou dans le grenier ou le vide sanitaire. 3. Dans le faux grenier, marquer ('emplacement de I'ouverture dans fe plafond en utilisant le boitier comme guide. Le cote le plus long de I'ouverture dolt etre parallele a la poutre. 4. Damper le long de le ligne marquee. REMAROUE: 81 le plafond est en pl5tre, 0 est preferable de decouper per en dessous, afin de ne pas dallier le pl5tre. 5. Poser le boitier, raccorder les file 5lectriques et conduits, poser i'ensemble moteur /ventilateur et la grille. B01T:2R I DEBOUCHURE VIS DE MONTAGE RESSORT DE I MONTAGE OUVERTURE DE DECHARGE BOSSAGE CRANTE PATTE DE FIXATION PLAQUE DE MONTAGE DU MOTEUR RESSORT DE MONTAGE LA GRILLE FIGURE 3 Nubne Gara11t1C 111111tee d'ui'1 an GA#ANt1E DU PROPRIEtAIRE: NuTane garantie a tacheteur original de ses proctor's que ces demiers seront exempts de tout Maul de materaut el de lab',cation pout une periode dun (1) an A compter de la date dachat AUCUNE AUtfE OARANTIE, IMPIJCtIE OU EXPRESSE, N ESt DOHNEE, Y COMPfUS, MAIS SANS IVY LIMITER, OAAANt1E DE MARCNANOttl1UtE OU D'AbAPTAtION A UN USAGE PARticbutr . Pendent abbe petted. dun 8n, Nutaie ptottdera au tertiplaceenent d)tl A la reparation sans auto.% trait, tnais A SA mote t&rsctefbn. de lout prnduil Cu piece lug§ deledueut daft !e cadre dune utilisatitxt notntale. GEttE OAAAtttIE tit VISE PAS tts 0ISPOSmFS tTAMbticAOE NI Lt s 'RIMS tits LUMINAIRES PLUO$ESCtUtS. Cette gatar:tie Ix; aouvte pas (a) I enttetien el le tenet* couraMM9 M (b) let ptoduts et let pieces aiant tat rob4§t dun usage SIAM, de negligence, dun at ident, dud enitetien ou dun* te0eta66n h l ite ipttee (Am au own* ruin autonse pat Nutorte), duns ttieuveisp Msste*etiOn du dune trittallatbn non toMoreie runt dkrecWes dxtstaM,ttien 000 1%4. §. La *Mt de khAda gate» tie POP est prtr*ei A le pdirtede de deu* aft tee€itee out le Oteeftie e►pres§@. Ckrlain§ alai§ rip wont AAA Ip4 re4trititn§ tetAlrre4 A IA durOA dr3§ getdntios w, lip§, II se pftulert dent due tMUr rettnil«en r5 §'ap gigue pa§ den§ Yoga ra§ LC RIIMPLACtUIINT OU LA RIPARATION PAR NUTONQ, A BA PROPRc alscagTION, DC TOUT PnODUIT OU mica DIEtcTUtux COHBTITUC LC ICUL RCMIOi 01 L'ACNBTCUR CN VinYU DC CCTTM OARANTIC, NUTON( NB PCUT ORB TCNUI RUPONBABLC Dio DOMMAOto INDIRCCTB, CONSICUTIPS OU oPICIAUX ATTRIBUABLCO A L'UTILISATIOH OU AU RINDIIMIINT DU PRODUIT, G€eitl4ine etele he 10(Onti4wnl Prue tee te§ut€t triti to lee bottokeiti iel411 @§ tea d,_ e*Sie€14: €oistoeil§ (M1 §t €'tau 44. t'fMMld4 *et 40 €ette Iti tk€W, i foe VetiOlittite pet (14/te veep CAS ld 1404entei tWerthes IrOu4 dttenle de§ Wan §p+4+E1tlgUe§. Hord§ v*Mt§ teedt t aue41 MK* d eirtie§ dttA§ ettt WOW de 1 et41 croi§ ioti vuv§ rotiol Chita 44tdtN M Iteeo4e€e teele dude gefeeee donee@ visolldeeetwe uRVICI IOUS OARANTIC Pow Ike **Wild* au service sous gamed', vous Owes p) eels*, NYTone,1 lidless* townie ct deems ou pet telephone au 1 Odd 643 =3617, (b) lou►nlr N numko du noddle el IA deeertptlon de la piece et (e) dkrin la Mute du delaut de la piece ou du prodult, Au moment de la domande de service sous wank, elms dove (wolf une pewee de la dale d'schat orlginele, Poe 0 utstakatpst €neepreneur o tnstai i ur N' q4 mo tale et deracet{ttion du Pg404 POUR ORTBNIR OC L'ABBIBTANCC OU OU BERVtCCI Pouf conrtelue le COMM de §er,ACe Mane. 40n00 ut46per>dael Ip pie* proche: Residents doe Itels'Unls continenlaus, composes le owner* sane dlllel 1 844 543 8687 • Gamier it prtNAe de la main le num9r0 du nwiele • La date et la preuve d'adtat • Le type de problems. Realdanla 00 I'Akaka el d'HawsU: Ecnvet 8 NtiTona Inc. Attn: Department of National Ftetd Service, Madison and Red Sank Roads, Cincinnati Ohio USA 45227.1593 Reeldente du Canada: Ecrivoi 4 NuTona Canada Inc„ 6300 Tounken Road, Mississauga, Ontario Canada 15r t N2. Ray. 4199 Les caracteristiques peuvent etre modifides sans preavis NuTone Madison and Red Bank Roads, Cincinnati, Ohio 45227 Imprime aux E.•U. r , PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M2000 -250 DATE: 11 -8 -2000 PROJECT NAME: GRADING PACIFIC SITE ADDRESS: . 1.8338 ANDOVER PK W SUITE NO: .. XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # . , Revision # _._ After Permit Is Issued DRALTAlhat Buil Division Ih-oo Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Er Comments: TUES /THURS ROUTI G: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions REVIEWER'S INITIALS: Fire E P re venti n AUK (L�f Structural Incomplete Planning Division Permit Coordinator DUE DATE: 1 1- 9 -20QQ Not Applicable No further Review Required DATE: DUE DATE - 7 -2000 Not Approved (attach comments) E DATE: COKRECJION DETERMINATION: DUE DATE Approved E Approved with Conditions E Not Approved (attach comments) L REVIEWER'S INITIALS: DATE: r (:r,21- 0{2•(MNr 1!tnrlr DEPA1aNIIiNi 01: LABOR ANI) INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT SPECIALTY REGIST. # EXP. DATE CCAAAF FIVESM *010JT 04/30/2001 EFFECTIVE DATE 04/30/1999 FIVE STAR MECHANICAL 3902 W VALLEY HWY N STE 200 AUBURN WA 98001 -- t 1 it 111 s ORGANIZATION TYPE DOMESTIC PROFIT CORPORATION WARE ENTERPRISES INC. FIVE STAR MECHANICAL 3002 W VALLEY HWY N 1 AUBURN WA 98001 STATL Ot WASHINGTON TAX REGISTRATION UNEMPLOYMENT INSURANCE CITY OF BELLEVUE: GENERAL BUSINESS REGISTRATION REGISTERED TRADE NAMES: FIVE STAR MECHANICAL MASTER LICENSE SERVICE REGISTRATIONS AND LICENSES The above entity has been issued the business registrations or licenses listed DEPARTMENT OF LICENSING, BUSINESS 6 PROFESSIONS DIVISION. P.O. BOX 8034 OLYMPIA, WA 98507.9034 (360) 664.1400 INDUSTRIAL INSURANCE UNIFIED BUSINESS ID 0: 801 937 083 BUSINESS ID /: 001 LOCATION: 0001 =.i__________!_ ••••••"_*. • Type: ,,,., Alee-A-. C,,_ Make: Paotke... Model: 5 gOD Ei / 01 I SVVIVk Ilea ting Input (MBTUh): 150,00 0 Heating Output (MBTIlh): t 3, 000 AFUE (%): 00 CFM ® S.P.: woo e S Nominal Cooling (MBTUh): . 7 voo SEER: 0 E lz. 8.5 Electrical Requirements: 5W,,,.,+ /3 p„ MCA MAX D-O Economizer: Y...5 Outside Air: Yes Factory Curb: ' p.1' -.),:;,„, Ye.5 Filter Qty, Size, Type: 1 Total Weight: 5, cow I21 r _ �� / / / ____-- / li / v /7 " 4 , / / / / Type: ,,,., Alee-A-. C,,_ Make: Paotke... Model: 5 gOD Ei / 01 I SVVIVk Ilea ting Input (MBTUh): 150,00 0 Heating Output (MBTIlh): t 3, 000 AFUE (%): 00 CFM ® S.P.: woo e S Nominal Cooling (MBTUh): . 7 voo SEER: 0 E lz. 8.5 Electrical Requirements: 5W,,,.,+ /3 p„ MCA MAX D-O Economizer: Y...5 Outside Air: Yes Factory Curb: ' Filter Assembly: Ye.5 Filter Qty, Size, Type: 1 Total Weight: 5 (.., 5 18'—* REFLECTED CEILING PLAN 1/4" 134 'iS0Ita:ok) ■ tAnprov ,,, - , * 12' — r HVAC 220.00 R.j 1 coi\ - 12- 3? EQUIPMENT SCHEDULE VICINITY MAP NTS rn s -so zwo ENLARGED FLOOR PLAN 1/4.. A00 N47„',4-L'I500 ° N DUCTWORK: p1)._ 0 FILE COPY I understand that the Plan Check approvals are subject to errors and omlssions and approval of plans does not authorize the violation of any adopted code or ordinance. Recei of con- tractor's c y of ap roved pin .o o: .owledged. • By Date Permit No -MO 0 1 Ao 150 Fo, SEPARATE PERMIT REQUIRED FOR: . D MECHANICAL ffELECTRICAL 0 PLUMBING • ;I ffGAS PIPING CITY OF TUKWILA BUILDING DIVISION REVISIONS NO CHANGES SHALL BE MADE TO THE SCOPE OF WORK WITHOUT PRIOR PROVAL OF TUKWILA BUILDING DIVIEI1, NOM REVIOTONS WILL REQUIRE A NEW riAit sus, - AND LW INCLUDE ADDITIONAL PLAN REVIEW FELS. All ductwork shall be installed per SMACNA low velocity and duct constmction manual. Duct hangers, mpports and methods of installation shall conform to ASHRAE and SIVIACNA recommendations and shall comply with local and state codes and standards. All ductwork shall be Class-1 air duct as approved by U.L.-181. Provide lockable vclume damgers in all distribution outlet,. Taming vanes shall be provided in all tees and where space prohibilo the use of smooth radius elbows. All duct dimensions are inside dimensions and assume no internal insulation is installed. Ductwork shall be insulated where applicable to comply with WSEC and SEC. Insulation, if required, shall be extemal, 1" thick, fire retardant fiberglass with a „. • reinforced aluminum foil jacked. Tape shall be aluminum foil and shall be approved for use by SMACNA. WORK By OTHER TRADESz Lint voltage wiring and connections by ELECTRICAL CONTRACTOR: Field-vetify nameplate data for exact requirements. ELECTRICAL CONTRACTOR shall provide weather-tight convenience outlet within 25' cf each roof-motue,d unit ROOFING CONTRACTOR to provide 0001 55p. insulation and roofing to match over roof curbs and sleepers as appropriate for SF-1,2. (011 1051002 cutting, patching and painting Mall be by GENERAL CONTRACTOR, ; '351 0 E